1
|
Yilmaz B, Ayyildiz S, Kalyoncuoglu UT, Tahmasebifar A, Baran ET. Surface characteristics of additively manufactured CoCr and Ti6Al4V dental alloys: The effects of carbon and gold thin film coatings, and alkali-heat treatment. Microsc Res Tech 2024; 87:1222-1240. [PMID: 38318995 DOI: 10.1002/jemt.24501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/12/2023] [Accepted: 01/08/2024] [Indexed: 02/07/2024]
Abstract
This study investigates the impact of surface modifications on additively manufactured CoCr and Ti6Al4V dental alloys, focusing on surface properties. Thin film carbon (C) and gold (Au) coatings, as well as alkali-heat treatment, were applied to the high- and low-polished specimens. Scanning electron microscopy (SEM) showed that thin film coatings retained the underlying surface topography, while the alkali-heat treatment induced distinct morphological changes. Energy-dispersive x-ray spectroscopy (EDS) analysis revealed that C-coating enriched surfaces with C, and Au-coating introduced detectable amounts of Au. Nevertheless, signs of coating delamination were observed in the high-polished specimens. Alkali-heat treatment led to the formation of a sodium titanate layer on Ti6Al4V surfaces, confirmed by sodium presence and Fourier transform infrared spectroscopy (FTIR) results showing carbonate bands. Surface roughness measurements with atomic force microscopy (AFM) showed that C-coating increased surface roughness in both high- and low-polished alloys. Au-coating slightly increased roughness, except for low-polished Au-coated Ti6Al4V, where a decrease in roughness was observed compared to low-polished bare Ti6Al4V, likely due to surface defects present in the latter resulting from the additive manufacturing process. Alkali-heat treatment led to a pronounced increase in roughness for both alloys, particularly for Ti6Al4V. Both thin film coatings decreased the water contact angles in all specimens in varying magnitudes, indicating an increase in wettability. However, the alkali-heat treatment caused a substantial decrease in contact angles, resulting in a highly hydrophilic state for Ti6Al4V. These findings underscore the substantial impact of surface modifications on additively manufactured dental alloys, potentially influencing their clinical performance. RESEARCH HIGHLIGHTS: Thin film coatings and chemical/heat treatment modify the surface properties of additively manufactured dental alloys. The surfaces of the alloys get rougher and more hydrophilic after alkali-heat treatment. Thin gold coatings exhibit potential adhesion challenges.
Collapse
Affiliation(s)
- Bengi Yilmaz
- Department of Biomaterials, University of Health Sciences Turkey, Istanbul, Turkey
- Gulhane Medical Design and Manufacturing Center (METUM), University of Health Sciences Turkey, Ankara, Turkey
- Regenerative Medicine Application and Research Center, University of Health Sciences Turkey, Istanbul, Turkey
| | - Simel Ayyildiz
- Gulhane Medical Design and Manufacturing Center (METUM), University of Health Sciences Turkey, Ankara, Turkey
- Department of Prosthodontics, Gulhane Faculty of Dentistry, University of Health Sciences Turkey, Ankara, Turkey
| | - Ulku Tugba Kalyoncuoglu
- Department of Prosthodontics, Gulhane Faculty of Dentistry, University of Health Sciences Turkey, Ankara, Turkey
| | - Aydin Tahmasebifar
- Department of Biomaterials, University of Health Sciences Turkey, Istanbul, Turkey
- Regenerative Medicine Application and Research Center, University of Health Sciences Turkey, Istanbul, Turkey
| | - Erkan Türker Baran
- Regenerative Medicine Application and Research Center, University of Health Sciences Turkey, Istanbul, Turkey
- Department of Tissue Engineering, University of Health Sciences Turkey, Istanbul, Turkey
| |
Collapse
|
2
|
Moghaddam A, Bahrami M, Mirzadeh M, Khatami M, Simorgh S, Chimehrad M, Kruppke B, Bagher Z, Mehrabani D, Khonakdar HA. Recent trends in bone tissue engineering: a review of materials, methods, and structures. Biomed Mater 2024; 19:042007. [PMID: 38636500 DOI: 10.1088/1748-605x/ad407d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 04/18/2024] [Indexed: 04/20/2024]
Abstract
Bone tissue engineering (BTE) provides the treatment possibility for segmental long bone defects that are currently an orthopedic dilemma. This review explains different strategies, from biological, material, and preparation points of view, such as using different stem cells, ceramics, and metals, and their corresponding properties for BTE applications. In addition, factors such as porosity, surface chemistry, hydrophilicity and degradation behavior that affect scaffold success are introduced. Besides, the most widely used production methods that result in porous materials are discussed. Gene delivery and secretome-based therapies are also introduced as a new generation of therapies. This review outlines the positive results and important limitations remaining in the clinical application of novel BTE materials and methods for segmental defects.
Collapse
Affiliation(s)
| | - Mehran Bahrami
- Department of Mechanical Engineering and Mechanics, Lehigh University, 27 Memorial Dr W, Bethlehem, PA 18015, United States of America
| | | | - Mehrdad Khatami
- Iran Polymer and Petrochemical Institute (IPPI), Tehran 14965-115, Iran
| | - Sara Simorgh
- Department of Tissue Engineering and Regenerative Medicine, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Mohammadreza Chimehrad
- Department of Mechanical & Aerospace Engineering, College of Engineering & Computer Science, University of Central Florida, Orlando, FL, United States of America
| | - Benjamin Kruppke
- Max Bergmann Center of Biomaterials and Institute of Materials Science, Technische Universität Dresden, 01069 Dresden, Germany
| | - Zohreh Bagher
- Department of Tissue Engineering and Regenerative Medicine, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Davood Mehrabani
- Burn and Wound Healing Research Center, Shiraz University of Medical Sciences, Shiraz, Fars 71348-14336, Iran
- Stem Cell Technology Research Center, Shiraz University of Medical Sciences, Shiraz, Fars 71345-1744, Iran
| | - Hossein Ali Khonakdar
- Iran Polymer and Petrochemical Institute (IPPI), Tehran 14965-115, Iran
- Max Bergmann Center of Biomaterials and Institute of Materials Science, Technische Universität Dresden, 01069 Dresden, Germany
| |
Collapse
|
3
|
Nunes FC, Santos SIP, Colnago LA, Hammer P, Ferreira JA, Ambrósio CE, Pallone EMJA. Impact of ZrO 2 Content on the Formation of Sr-Enriched Phosphates in Al 2O 3/ZrO 2 Nanocomposites for Bone Tissue Engineering. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1893. [PMID: 38673250 PMCID: PMC11052522 DOI: 10.3390/ma17081893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 03/26/2024] [Accepted: 03/28/2024] [Indexed: 04/28/2024]
Abstract
This study investigates the profound impact of the ZrO2 inclusion volume on the characteristics of Al2O3/ZrO2 nanocomposites, particularly influencing the formation of calcium phosphates on the surface. This research, aimed at advancing tissue engineering, prepared nanocomposites with 5, 10, and 15 vol% ZrO2, subjecting them to chemical surface treatment for enhanced calcium phosphate deposition sites. Biomimetic coating with Sr-enriched simulated body fluid (SBF) further enhanced the bioactivity of nanocomposites. While the ZrO2 concentration heightened the oxygen availability on nanocomposite surfaces, the quantity of Sr-containing phosphate was comparatively less influenced than the formation of calcium phosphate phases. Notably, the coated nanocomposites exhibited a high cell viability and no toxicity, signifying their potential in bone tissue engineering. Overall, these findings contribute to the development of regenerative biomaterials, holding promise for enhancing bone regeneration therapies.
Collapse
Affiliation(s)
- Fabio Caixeta Nunes
- Postgraduate Programme in Materials Science and Engineering, Faculty of Animal Science and Food Engineering (FZEA), University of São Paulo (USP), Av. Duque de Caxias Norte, 225, Pirassununga 13635-900, SP, Brazil;
| | - Sarah Ingrid Pinto Santos
- Department of Veterinary Medicine, Faculty of Animal Science and Food Engineering (FZEA), University of São Paulo (USP), Pirassununga 13635-900, SP, Brazil; (S.I.P.S.); (C.E.A.)
| | - Luiz Alberto Colnago
- Brazilian Agricultural Research Corporation, EMBRAPA Instrumentation, Rua Quinze de Novembro, 1500/1501, São Carlos 13561-206, SP, Brazil;
| | - Peter Hammer
- Institute of Chemistry, São Paulo State University (UNESP), Araraquara 14800-900, SP, Brazil;
| | - Julieta Adriana Ferreira
- Fundação Hermínio Ometto, Fundação Hermínio Ometto (FHO), Av. Dr. Maximiliano Baruto, 500, Araras 13607-339, SP, Brazil;
| | - Carlos Eduardo Ambrósio
- Department of Veterinary Medicine, Faculty of Animal Science and Food Engineering (FZEA), University of São Paulo (USP), Pirassununga 13635-900, SP, Brazil; (S.I.P.S.); (C.E.A.)
| | - Eliria Maria Jesus Agnolon Pallone
- Postgraduate Programme in Materials Science and Engineering, Faculty of Animal Science and Food Engineering (FZEA), University of São Paulo (USP), Av. Duque de Caxias Norte, 225, Pirassununga 13635-900, SP, Brazil;
- Department of Biosystem Engineering, Faculty of Animal Science and Food Engineering (FZEA), University of São Paulo (USP), Pirassununga 13635-900, SP, Brazil
| |
Collapse
|
4
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
5
|
Travnickova M, Filova E, Slepicka P, Slepickova Kasalkova N, Kocourek T, Zaloudkova M, Suchy T, Bacakova L. Titanium-Doped Diamond-like Carbon Layers as a Promising Coating for Joint Replacements Supporting Osteogenic Differentiation of Mesenchymal Stem Cells. Int J Mol Sci 2024; 25:2837. [PMID: 38474083 DOI: 10.3390/ijms25052837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 02/17/2024] [Accepted: 02/22/2024] [Indexed: 03/14/2024] Open
Abstract
Diamond-like carbon (DLC) layers are known for their high corrosion and wear resistance, low friction, and high biocompatibility. However, it is often necessary to dope DLC layers with additional chemical elements to strengthen their adhesion to the substrate. Ti-DLC layers (doped with 0.4, 2.1, 3.7, 6.6, and 12.8 at.% of Ti) were prepared by dual pulsed laser deposition, and pure DLC, glass, and polystyrene (PS) were used as controls. In vitro cell-material interactions were investigated with an emphasis on cell adhesion, proliferation, and osteogenic differentiation. We observed slightly increasing roughness and contact angle and decreasing surface free energy on Ti-DLC layers with increasing Ti content. Three-week biological experiments were performed using adipose tissue-derived stem cells (ADSCs) and bone marrow mesenchymal stem cells (bmMSCs) in vitro. The cell proliferation activity was similar or slightly higher on the Ti-doped materials than on glass and PS. Osteogenic cell differentiation on all materials was proved by collagen and osteocalcin production, ALP activity, and Ca deposition. The bmMSCs exhibited greater initial proliferation potential and an earlier onset of osteogenic differentiation than the ADSCs. The ADSCs showed a slightly higher formation of focal adhesions, higher metabolic activity, and Ca deposition with increasing Ti content.
Collapse
Affiliation(s)
- Martina Travnickova
- Laboratory of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 00 Prague, Czech Republic
| | - Elena Filova
- Laboratory of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 00 Prague, Czech Republic
- Faculty of Materials and Technology, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic
| | - Petr Slepicka
- Department of Solid State Engineering, University of Chemistry and Technology Prague, Technicka 5, 166 28 Prague, Czech Republic
| | - Nikola Slepickova Kasalkova
- Department of Solid State Engineering, University of Chemistry and Technology Prague, Technicka 5, 166 28 Prague, Czech Republic
| | - Tomas Kocourek
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
- Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, 272 01 Kladno, Czech Republic
| | - Margit Zaloudkova
- Institute of Rock Structure and Mechanics, Czech Academy of Sciences, V Holesovickach 94/41, 182 09 Prague, Czech Republic
| | - Tomas Suchy
- Institute of Rock Structure and Mechanics, Czech Academy of Sciences, V Holesovickach 94/41, 182 09 Prague, Czech Republic
| | - Lucie Bacakova
- Laboratory of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, 142 00 Prague, Czech Republic
- Faculty of Materials and Technology, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic
| |
Collapse
|
6
|
Haitao X, Siyuan L, Sutong G, Yu G, Peirong X, Ling W, Yujian D, Dehong F. Preparation of Cu 2+/TA/HAP composite coating with anti-bacterial and osteogenic potential on 3D-printed porous Ti alloy scaffolds for orthopedic applications. Open Life Sci 2024; 19:20220826. [PMID: 38465344 PMCID: PMC10921476 DOI: 10.1515/biol-2022-0826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 12/16/2023] [Accepted: 12/20/2023] [Indexed: 03/12/2024] Open
Abstract
Because of stress shielding effects, traditional titanium (Ti) alloy scaffolds have a high elastic modulus, which might promote looseness and bone disintegration surrounding the implant, increasing the likelihood of a second surgery. In contrast, 3D-printed porous Ti alloy scaffolds can reduce the scaffold weight while enhancing biocompatibility. Further, these scaffolds' porous nature allows bone tissue ingrowth as well as strong pore connectivity, which can improve nutrient absorption. Nevertheless, bare Ti alloy implants may fail because of inadequate bone integration; hence, adding a coating on the implant surface is an effective technique for improving implant stability. In this study, a composite coating comprising hydroxyapatite (HAP), chitosan (CS), tannic acid (TA) and copper ions (Cu2+) (Cu2+/TA/HAP composite coating) was prepared on the surface of 3D printed porous Ti alloy scaffolds using electrophoretic deposition. Using the standard plate count method, Live/Dead bacteria staining assay, FITC Phalloidin and 4',6-diamidino-2-phenylindole staining assay, and live/dead staining of cells we determined that the composite coating has better antibacterial properties and cytocompatibility as well as lower cytotoxicity. The Alkaline Phosphatase assay revealed that the coating results showed good osteogenesis potential. Overall, the composite coatings produced in this investigation give new potential for the application of Ti alloys in clinics.
Collapse
Affiliation(s)
- Xu Haitao
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| | - Li Siyuan
- School of Chemical and Material Engineering, Jiangnan University, Wuxi214000, Jiangsu, China
| | - Guo Sutong
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| | - Guo Yu
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| | - Xu Peirong
- Wuxi No. 5 People’s Hospital, Wuxi214000, Jiangsu, China
| | - Wang Ling
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| | - Ding Yujian
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| | - Feng Dehong
- Wuxi People’s Hospital of Nanjing Medical University, Wuxi214000, Jiangsu, China
| |
Collapse
|
7
|
Al-Kaisy HA, Al-Tamimi BH, Hamad QA, Abed MS. Investigation of Roughness, Morphology, and Wettability Characteristics of Biopolymer Composite Coating on SS 316L for Biomedical Applications. Int J Biomater 2024; 2024:5568047. [PMID: 38268700 PMCID: PMC10807940 DOI: 10.1155/2024/5568047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 02/10/2023] [Accepted: 02/11/2023] [Indexed: 01/26/2024] Open
Abstract
This project aims to create a 316L stainless steel coated with a biocomposite based on chitosan for use in the biomedical industry. To completely coat the material, the dip-coating technique was used to apply plain chitosan, chitosan nanosilver, chitosan biotin, and chitosan-nanosilver-biotin in that order. This coating's surface morphology was investigated with field emission scanning electron microscopy (FESEM). Surface roughness, average size distribution, and 2D and 3D surface tomography were all investigated using scanning probe microscopy and atomic force microscopy (SPM and AFM). The Fourier transform infrared (FTIR) spectroscopy technique was used to quantify changes in functional groups. To evaluate the coated samples' wettability, contact angle measurements were also performed. The chitosan (CS) + nanosilver, CS + biotin, and CS + biotin + nanosilver-coated 316L stainless steel showed roughness values of about 8.68, 4.21, and 3.3 nm, respectively, compared with the neat chitosan coating, which exhibits 12 nm roughness, indicating a strong effect of biotin and nanosilver on surface topography whereas the coating layers were homogenous, measuring around 33 nm in thickness. For CS + nanosilver and CS + biotin, the average size of agglomerates was approximately 444 nm and 355 nm, respectively. The coatings showed adequate wettability for biomedical applications, were homogeneous, and had no cracks. Their contact angles were around 51-75 degrees. All of these results point to the composite coating's intriguing potential for use in biological applications.
Collapse
Affiliation(s)
- Hanaa A. Al-Kaisy
- Department of Materials Engineering, University of Technology, Baghdad, Iraq
| | - Basma H. Al-Tamimi
- Department of Materials Engineering, University of Technology, Baghdad, Iraq
| | - Qahtan A. Hamad
- Department of Materials Engineering, University of Technology, Baghdad, Iraq
| | - Mayyadah S. Abed
- Department of Materials Engineering, University of Technology, Baghdad, Iraq
| |
Collapse
|
8
|
Abaszadeh F, Ashoub MH, Khajouie G, Amiri M. Nanotechnology development in surgical applications: recent trends and developments. Eur J Med Res 2023; 28:537. [PMID: 38001554 PMCID: PMC10668503 DOI: 10.1186/s40001-023-01429-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 10/03/2023] [Indexed: 11/26/2023] Open
Abstract
This paper gives a detailed analysis of nanotechnology's rising involvement in numerous surgical fields. We investigate the use of nanotechnology in orthopedic surgery, neurosurgery, plastic surgery, surgical oncology, heart surgery, vascular surgery, ophthalmic surgery, thoracic surgery, and minimally invasive surgery. The paper details how nanotechnology helps with arthroplasty, chondrogenesis, tissue regeneration, wound healing, and more. It also discusses the employment of nanomaterials in implant surfaces, bone grafting, and breast implants, among other things. The article also explores various nanotechnology uses, including stem cell-incorporated nano scaffolds, nano-surgery, hemostasis, nerve healing, nanorobots, and diagnostic applications. The ethical and safety implications of using nanotechnology in surgery are also addressed. The future possibilities of nanotechnology are investigated, pointing to a possible route for improved patient outcomes. The essay finishes with a comment on nanotechnology's transformational influence in surgical applications and its promise for future breakthroughs.
Collapse
Affiliation(s)
- Farzad Abaszadeh
- Student Research Committee, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran
- Neuroscience Research Center, Institute of Neuropharmacology, Kerman University of Medical Science, Kerman, Iran
| | - Muhammad Hossein Ashoub
- Department of Hematology and Medical Laboratory Sciences, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran
- Cell Therapy and Regenerative Medicine Comprehensive Center, Kerman University of Medical Sciences, Kerman, Iran
| | - Ghazal Khajouie
- Neuroscience Research Center, Institute of Neuropharmacology, Kerman University of Medical Science, Kerman, Iran
| | - Mahnaz Amiri
- Student Research Committee, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran.
- Neuroscience Research Center, Institute of Neuropharmacology, Kerman University of Medical Science, Kerman, Iran.
| |
Collapse
|
9
|
Dua R, Sharufa O, Terry J, Dunn W, Khurana I, Vadivel J, Zhang Y, Donahue HJ. Surface modification of Polyether-ether-ketone for enhanced cell response: a chemical etching approach. Front Bioeng Biotechnol 2023; 11:1202499. [PMID: 37744253 PMCID: PMC10517429 DOI: 10.3389/fbioe.2023.1202499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/28/2023] [Indexed: 09/26/2023] Open
Abstract
Polyether-ether-ketone (PEEK) is increasingly becoming popular in medicine because of its excellent mechanical strength, dimensional stability, and chemical resistance properties. However, PEEK being bioinert, has weak bone osseointegration properties, limiting its clinical applications. In this study, a porous PEEK structure was developed using a chemical etching method with 98 wt% sulfuric acids and three post-treatments were performed to improve bone cell adhesion and proliferation. Four groups of PEEK samples were prepared for the study: Control (untreated; Group 1); Etched with sulfuric acid and washed with distilled water (Group 2); Etched with sulfuric acid and washed with acetone and distilled water (Group 3); and Etched with sulfuric acid and washed with 4 wt% sodium hydroxide and distilled water (Group 4). Surface characterization of the different groups was evaluated for surface topology, porosity, roughness, and wettability using various techniques, including scanning electron microscopy, profilometer, and goniometer. Further chemical characterization was done using Energy-dispersive X-ray spectroscopy to analyze the elements on the surface of each group. Bone cell studies were conducted using cell toxicity and alkaline phosphatase activity (ALP) assays. The SEM analysis of the different groups revealed porous structures in the treatment groups, while the control group showed a flat topology. There was no statistically significant difference between the pore size within the treated groups. This was further confirmed by the roughness values measured with the profilometer. We found a statistically significant increase in the roughness from 7.22 × 10-3 μm for the control group to the roughness range of 0.1 µm for the treated groups (Groups 2-4). EDX analysis revealed the presence of a 0.1% weight concentration of sodium on the surface of Group 4, while sulfur weight percentage concentration was 1.1%, 0.1%, and 1.4% in groups 2, 3, and 4, respectively, indicating different surface chemistry on the surface due to different post-treatments. Cell toxicity decreased, and ALP activity increased in groups 3 and 4 over 7 days compared with the control group. It is demonstrated that the surface modification of PEEK using a chemical etching method with post-processing with either acetone or sodium hydroxide provides a nano-porous structure with improved properties, leading to enhanced osteoblastic cell differentiation and osteogenic potential.
Collapse
Affiliation(s)
- Rupak Dua
- American Dental Association Science and Research Institute (ADASRI), Gaithersburg, MD, United States
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Onessa Sharufa
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Joi Terry
- Department of Biology, Hampton University, Hampton, VA, United States
| | - William Dunn
- The New Horizons Governor’s School for Science and Technology, Hampton, VA, United States
| | - Indu Khurana
- Department of Economics and Business, Hampden-Sydney College, Hampden-Sydney, VA, United States
| | - Jagasivamani Vadivel
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Yue Zhang
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Henry J. Donahue
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States
| |
Collapse
|
10
|
Shang J, Zhou C, Jiang C, Huang X, Liu Z, Zhang H, Zhao J, Liang W, Zeng B. Recent developments in nanomaterials for upgrading treatment of orthopedics diseases. Front Bioeng Biotechnol 2023; 11:1221365. [PMID: 37621999 PMCID: PMC10446844 DOI: 10.3389/fbioe.2023.1221365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 07/11/2023] [Indexed: 08/26/2023] Open
Abstract
Nanotechnology has changed science in the last three decades. Recent applications of nanotechnology in the disciplines of medicine and biology have enhanced medical diagnostics, manufacturing, and drug delivery. The latest studies have demonstrated this modern technology's potential for developing novel methods of disease detection and treatment, particularly in orthopedics. According to recent developments in bone tissue engineering, implantable substances, diagnostics and treatment, and surface adhesives, nanomedicine has revolutionized orthopedics. Numerous nanomaterials with distinctive chemical, physical, and biological properties have been engineered to generate innovative medication delivery methods for the local, sustained, and targeted delivery of drugs with enhanced therapeutic efficacy and minimal or no toxicity, indicating a very promising strategy for effectively controlling illnesses. Extensive study has been carried out on the applications of nanotechnology, particularly in orthopedics. Nanotechnology can revolutionize orthopedics cure, diagnosis, and research. Drug delivery precision employing nanotechnology using gold and liposome nanoparticles has shown especially encouraging results. Moreover, the delivery of drugs and biologics for osteosarcoma is actively investigated. Different kind of biosensors and nanoparticles has been used in the diagnosis of bone disorders, for example, renal osteodystrophy, Paget's disease, and osteoporosis. The major hurdles to the commercialization of nanotechnology-based composite are eventually examined, thus helping in eliminating the limits in connection to some pre-existing biomaterials for orthopedics, important variables like implant life, quality, cure cost, and pain and relief from pain. The potential for nanotechnology in orthopedics is tremendous, and most of it looks to remain unexplored, but not without challenges. This review aims to highlight the up tp date developments in nanotechnology for boosting the treatment modalities for orthopedic ailments. Moreover, we also highlighted unmet requirements and present barriers to the practical adoption of biomimetic nanotechnology-based orthopedic treatments.
Collapse
Affiliation(s)
- Jinxiang Shang
- Department of Orthopedics, Affiliated Hospital of Shaoxing University, Shaoxing, China
| | - Chao Zhou
- Department of Orthopedics, Zhoushan Guanghua Hospital, Zhoushan, China
| | - Chanyi Jiang
- Department of Pharmacy, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Xiaogang Huang
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Zunyong Liu
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Hengjian Zhang
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Jiayi Zhao
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Wenqing Liang
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| | - Bin Zeng
- Department of Orthopedics, Zhoushan Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Zhoushan, China
| |
Collapse
|
11
|
Dasan A, Chandrasekar A. Special Issue: Bioceramics, Bioglasses, and Gels for Tissue Engineering. Gels 2023; 9:586. [PMID: 37504465 PMCID: PMC10379387 DOI: 10.3390/gels9070586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 07/16/2023] [Indexed: 07/29/2023] Open
Abstract
Undoubtedly, biomaterials such as bioceramics, bioactive glasses, and gels have attracted a wide range of research interest in the field of tissue engineering (TE), as they facilitate the essential support and environment for cells to grow, differentiate, and, specifically, regenerate new tissues [...].
Collapse
Affiliation(s)
- Arish Dasan
- FunGlass, Alexander Dubček University of Trenčín, 911 50 Trenčín, Slovakia
| | | |
Collapse
|
12
|
Birkett M, Zia AW, Devarajan DK, Panayiotidis MI, Joyce TJ, Tambuwala MM, Serrano-Aroca A. Multi-functional bioactive silver- and copper-doped diamond-like carbon coatings for medical implants. Acta Biomater 2023:S1742-7061(23)00363-X. [PMID: 37392935 DOI: 10.1016/j.actbio.2023.06.037] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 06/09/2023] [Accepted: 06/26/2023] [Indexed: 07/03/2023]
Abstract
Diamond-like carbon (DLC) coatings doped with bioactive elements of silver (Ag) and copper (Cu) have been receiving increasing attention in the last decade, particularly in the last 5 years, due to their potential to offer a combination of enhanced antimicrobial and mechanical performance. These multi-functional bioactive DLC coatings offer great potential to impart the next generation of load-bearing medical implants with improved wear resistance and strong potency against microbial infections. This review begins with an overview of the status and issues with current total joint implant materials and the state-of-the art in DLC coatings and their application to medical implants. A detailed discussion of recent advances in wear resistant bioactive DLC coatings is then presented with a focus on doping the DLC matrix with controlled quantities of Ag and Cu elements. It is shown that both Ag and Cu doping can impart strong antimicrobial potency against a range of Gram-positive and Gram-negative bacteria, but this is always accompanied so far by a reduction in mechanical performance of the DLC coating matrix. The article concludes with discussion of potential synthesis methods to accurately control bioactive element doping without jeopardising mechanical properties and gives an outlook to the potential long-term impact of developing a superior multifunctional bioactive DLC coating on implant device performance and patient health and wellbeing. STATEMENT OF SIGNIFICANCE: Multi-functional diamond-like carbon (DLC) coatings doped with bioactive elements of silver (Ag) and copper (Cu) offer great potential to impart the next generation of load-bearing medical implants with improved wear resistance and strong potency against microbial infections. This article provides a critical review of the state-of-the-art in Ag and Cu doped DLC coatings, beginning with an overview of the current applications of DLC coatings in implant technology followed by a detailed discussion of Ag/Cu doped DLC coatings with particular focus on the relationship between their mechanical and antimicrobial performance. Finally, it ends with a discussion on the potential long-term impact of developing a truly multifunctional ultra-hard wearing bioactive DLC coating to extend the lifetime of total joint implants.
Collapse
Affiliation(s)
- Martin Birkett
- Department of Mechanical and Construction Engineering, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK.
| | - Abdul Wasy Zia
- Institute of Mechanical, Process, and Energy Engineering (IMPEE), School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, UK
| | - Dinesh Kumar Devarajan
- Centre for Nanoscience and Nanotechnology, Sathyabama Institute of Science and Technology, Chennai, Tamil Nadu 600119, India
| | - Mihalis I Panayiotidis
- Department of Cancer Genetics Therapeutics and Ultrastructural Pathology, The Cyprus Institute of Neurology and Genetics, Nicosia, Cyprus
| | - Thomas J Joyce
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, UK
| | | | - Angel Serrano-Aroca
- Biomaterials and Bioengineering Lab, Centro de Investigación Traslacional San Alberto Magno, Universidad Católica de Valencia San Vicente Mártir, c/Guillem de Castro 94, 46001 Valencia, Spain
| |
Collapse
|
13
|
Scislo L. Verification of Mechanical Properties Identification Based on Impulse Excitation Technique and Mobile Device Measurements. SENSORS (BASEL, SWITZERLAND) 2023; 23:5639. [PMID: 37420804 DOI: 10.3390/s23125639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 06/09/2023] [Accepted: 06/13/2023] [Indexed: 07/09/2023]
Abstract
The Impulse Excitation Technique (IET) is one of the most useful testing methods for evaluating or calculating some material properties. This can be useful to evaluate and confirm that the material ordered is what was delivered. In the case of unknown materials, where their properties are required by simulation software, this is also a quick way to obtain mechanical properties and thus improve the simulation quality. The main drawback of the method is the requirement for a specialized sensor and acquisition system and a well-trained engineer to prepare the setup and analyze the results. The article evaluates the possibility of using a low-cost solution in the form of a mobile device microphone as a way to obtain data, which after the Fast Fourier Transform (FFT), allows to obtain frequency response graphs and use the IET method procedure to calculate the mechanical properties of the samples. The data obtained by the mobile device are compared with the data obtained by professional sensors and data acquisition systems. The results confirm that for typical homogenous materials, the mobile phone is a cheap and reliable alternative for fast, on-the-go material quality inspections and can be introduced even in small companies and on construction sites. Additionally, this kind of approach does not require specific knowledge of sensing technology, signal treatment, or data analysis and can be performed by any assigned employee, who can receive the quality check information immediately on-site. Additionally, the presented procedure allows data collection and transfer to the cloud for future references and additional information extraction. This element is fundamental for introducing sensing technologies under the Industry 4.0 concept.
Collapse
Affiliation(s)
- Lukasz Scislo
- Faculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland
| |
Collapse
|
14
|
Sheydaei M, Edraki M, Radeghi Mehrjou SM. Anticorrosion and Antimicrobial Evaluation of Sol-Gel Hybrid Coatings Containing Clitoria ternatea Modified Clay. Gels 2023; 9:490. [PMID: 37367160 DOI: 10.3390/gels9060490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 06/28/2023] Open
Abstract
In this study, Clitoria ternatea (CT) was incorporated into the structure of sodium montmorillonite (Na+-MMT), then these new nanoparticles (CT-MMT) were added to sol-gel-based hybrid silanol coatings (SGC). The results of the CT-MMT investigation using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscope (TEM) confirmed the presence of CT in the structure. The results of polarization and electrochemical impedance spectroscopy (EIS) tests showed that the presence of CT-MMT in the matrix improves corrosion resistance. The EIS results showed that the coating resistance (Rf) of the sample containing 3 wt.% CT-MMT after immersion was 687 Ω·cm2, while this value was 218 Ω·cm2 for pure coating. CT and MMT compounds improve corrosion resistance by blocking anodic and cathodic regions, respectively. Additionally, the presence of CT in the structure created antimicrobial properties. CT contains phenolic compounds that have the ability to suppress by membrane perturbation, reduction of host ligands adhesion, and neutralizing bacterial toxins. Therefore, CT-MMT showed inhibitory effects and killing of Staphylococcus aureus (gram-positive bacteria) and Salmonella paratyphi-A serotype (gram-negative bacteria), and also improved corrosion resistance.
Collapse
Affiliation(s)
- Milad Sheydaei
- Faculty of Polymer Engineering, Sahand University of Technology, Tabriz P.O. Box 51335-1996, Iran
| | - Milad Edraki
- Polymer Department, Technical Faculty, South Tehran Branch, Islamic Azad University, Tehran P.O. Box 19585-466, Iran
| | - Seyyed Mehdi Radeghi Mehrjou
- Department of Civil and Architecture Engineering, Technical and Vocational University of Iran [Guilan, Rasht (Chamran)], Tehran 1435661137, Iran
| |
Collapse
|
15
|
Szwajka K, Zielińska-Szwajka J, Trzepieciński T. Improving the Surface Integrity of 316L Steel in the Context of Bioimplant Applications. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093460. [PMID: 37176341 PMCID: PMC10180083 DOI: 10.3390/ma16093460] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 04/24/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023]
Abstract
Bioimplants should meet important surface integrity criteria, with the main goal of the manufacturing process to improve wear and corrosion resistance properties. This requires a special approach at the cutting stage. During this research, the impact of the cutting parameters on improving the surface integrity of AISI 316L steel was evaluated. In this context of bioimplant applications, the mean roughness Sa value was obtained in the range of 0.73-4.19 μm. On the basis of the results obtained, a significant effect was observed of both the cutting speed and the feed rate on changes in the microstructure of the near-surface layer. At a cutting speed of 150 m/min, the average grain size was approximately 31 μm. By increasing the cutting speed to 200 m/min, the average grain size increased to approximately 52 μm. The basic austenitic microstructure of AISI 316L steel with typical precipitation of carbides on the grain boundaries was refined at the near-surface layer after the machining process. Changing the cutting speed determined the hardness of the treated and near-surface layers. The maximum value of hardness is reached at a depth of 20 μm and decreases with the depth of measurement. It was also noted that at a depth of up to 240 μm, the maximum hardness of 270-305 HV1 was reached, hence the height of the machining impact zone can be determined, which is approximately 240 μm for almost all machining conditions.
Collapse
Affiliation(s)
- Krzysztof Szwajka
- Faculty of Mechanics and Technology, Department of Integrated Design and Tribology Systems, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland
| | - Joanna Zielińska-Szwajka
- Faculty of Mechanics and Technology, Department of Component Manufacturing and Production Organization, Rzeszow University of Technology, ul. Kwiatkowskiego 4, 37-450 Stalowa Wola, Poland
| | - Tomasz Trzepieciński
- Department of Manufacturing Processes and Production Engineering, Rzeszow University of Technology, al. Powstańców Warszawy 8, 35-959 Rzeszów, Poland
| |
Collapse
|
16
|
Jeong SH, Nguyen KT, Nguyen MT, You JS, Kim BH, Choe HC, Ahn SG. DMP1 and IFITM5 Regulate Osteogenic Differentiation of MC3T3-E1 on PEO-Treated Ti-6Al-4V-Ca 2+/P i surface. ACS Biomater Sci Eng 2023; 9:1377-1390. [PMID: 36802481 DOI: 10.1021/acsbiomaterials.2c01296] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Despite numerous studies on various surface modifications on titanium and its alloys, it remains unclear what kind of titanium-based surface modifications are capable of controlling cell activity. This study aimed to understand the mechanism at the cellular and molecular levels and investigate the in vitro response of osteoblastic MC3T3-E1 cultured on the Ti-6Al-4V surface modified by plasma electrolytic oxidation (PEO) treatment. A Ti-6Al-4V surface was prepared by PEO at 180, 280, and 380 V for 3 or 10 min in an electrolyte containing Ca2+/Pi ions. Our results showed that PEO-treated Ti-6Al-4V-Ca2+/Pi surfaces enhanced the cell attachment and differentiation of MC3T3-E1 compared to the untreated Ti-6Al-4V control but did not affect cytotoxicity as shown by cell proliferation and cell death. Interestingly, on the Ti-6Al-4V-Ca2+/Pi surface treated by PEO at 280 V for 3 or 10 min, MC3T3-E1 showed a higher initial adhesion and mineralization. In addition, the alkaline phosphatase (ALP) activity significantly increased in MC3T3-E1 on the PEO-treated Ti-6Al-4V-Ca2+/Pi (280 V for 3 or 10 min). In RNA-seq analysis, the expression of dentin matrix protein 1 (DMP1), sortilin 1 (Sort1), signal-induced proliferation-associated 1 like 2 (SIPA1L2), and interferon-induced transmembrane protein 5 (IFITM5) was induced during the osteogenic differentiation of MC3T3-E1 on the PEO-treated Ti-6Al-4V-Ca2+/Pi. DMP1 and IFITM5 silencing decreased the expression of bone differentiation-related mRNAs and proteins and ALP activity in MC3T3-E1. These results suggest that the PEO-treated Ti-6Al-4V-Ca2+/Pi surface induces osteoblast differentiation by regulating the expression of DMP1 and IFITM5. Therefore, surface microstructure modification through PEO coatings with Ca2+/Pi ions could be used as a valuable method to improve biocompatibility properties of titanium alloys.
Collapse
Affiliation(s)
- Se-Ho Jeong
- Department of Pathology, School of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Khanh Toan Nguyen
- Department of Pathology, School of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Manh Tuong Nguyen
- Department of Pathology, School of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Jae-Seek You
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Byung-Hoon Kim
- Advanced Functional Surface and Biomaterials Research Lab, Department of Dental Materials and Research Center of Surface Control for Oral Tissue Regeneration (BRL Center of NRF), College of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Han-Cheol Choe
- Advanced Functional Surface and Biomaterials Research Lab, Department of Dental Materials and Research Center of Surface Control for Oral Tissue Regeneration (BRL Center of NRF), College of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| | - Sang-Gun Ahn
- Department of Pathology, School of Dentistry, Chosun University, Gwangju 61452, Republic of Korea
| |
Collapse
|
17
|
Deposition of Chitosan on Plasma-Treated Polymers-A Review. Polymers (Basel) 2023; 15:polym15051109. [PMID: 36904353 PMCID: PMC10007447 DOI: 10.3390/polym15051109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 02/10/2023] [Accepted: 02/21/2023] [Indexed: 02/25/2023] Open
Abstract
Materials for biomedical applications often need to be coated to enhance their performance, such as their biocompatibility, antibacterial, antioxidant, and anti-inflammatory properties, or to assist the regeneration process and influence cell adhesion. Among naturally available substances, chitosan meets the above criteria. Most synthetic polymer materials do not enable the immobilization of the chitosan film. Therefore, their surface should be altered to ensure the interaction between the surface functional groups and the amino or hydroxyl groups in the chitosan chain. Plasma treatment can provide an effective solution to this problem. This work aims to review plasma methods for surface modification of polymers for improved chitosan immobilization. The obtained surface finish is explained in view of the different mechanisms involved in treating polymers with reactive plasma species. The reviewed literature showed that researchers usually use two different approaches: direct immobilization of chitosan on the plasma-treated surface or indirect immobilization by additional chemistry and coupling agents, which are also reviewed. Although plasma treatment leads to remarkably improved surface wettability, this was not the case for chitosan-coated samples, where a wide range of wettability was reported ranging from almost superhydrophilic to hydrophobic, which may have a negative effect on the formation of chitosan-based hydrogels.
Collapse
|
18
|
Marimuthu A, Logesh M, El Mabrouk K, Ballamurugan AM. In vitro hemocompatibility studies on small-caliber stents for cardiovascular applications. RSC Adv 2023; 13:6793-6799. [PMID: 36860538 PMCID: PMC9969537 DOI: 10.1039/d2ra06831a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Accepted: 02/08/2023] [Indexed: 03/02/2023] Open
Abstract
The doping of biologically meaningful ions into biphasic calcium phosphate (BCP) bioceramics, which exhibit biocompatibility with human body parts, has led to their effective use in biomedical applications in recent years. Doping with metal ions while changing the characteristics of the dopant ions, an arrangement of various ions in the Ca/P crystal structure. In our work, small-diameter vascular stents based on BCP and biologically appropriate ion substitute-BCP bioceramic materials were developed for cardiovascular applications. The small-diameter vascular stents were created using an extrusion process. FTIR, XRD, and FESEM were used to identify the functional groups, crystallinity, and morphology of the synthesized bioceramic materials. In addition, investigation of the blood compatibility of the 3D porous vascular stents was carried out via hemolysis. The outcomes indicate that the prepared grafts are appropriate for clinical requirements.
Collapse
Affiliation(s)
- Arumugam Marimuthu
- Department of Nanoscience and Technology, Bharathiar University Coimbatore-641046 India
| | - Mahendran Logesh
- Department of Nanoscience and Technology, Bharathiar University Coimbatore-641046 India
| | - Khalil El Mabrouk
- Euromed Engineering Faculty, Euromed Research Center, Euromed University of Fes, Eco-Campus, Campus UEMFFesMorocco
| | | |
Collapse
|
19
|
Huang W, Zhang Z, Qiu Y, Gao Y, Fan Y, Wang Q, Zhou Q. NLRP3 inflammasome activation in response to metals. Front Immunol 2023; 14:1055788. [PMID: 36845085 PMCID: PMC9950627 DOI: 10.3389/fimmu.2023.1055788] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 01/16/2023] [Indexed: 02/12/2023] Open
Abstract
Implant surgery is followed by a series of inflammatory reactions that directly affect its postoperative results. The inflammasome plays a vital role in the inflammatory response by inducing pyroptosis and producing interleukin-1β, which plays a critical role in inflammation and tissue damage. Therefore, it is essential to study the activation of the inflammasome in the bone healing process after implant surgery. As metals are the primary implant materials, metal-induced local inflammatory reactions have received significant attention, and there has been more and more research on the activation of the NLRP3 (NOD-like receptor protein-3) inflammasome caused by these metals. In this review, we consolidate the basic knowledge on the NLRP3 inflammasome structures, the present knowledge on the mechanisms of NLRP3 inflammasome activation, and the studies of metal-induced NLRP3 inflammasome activation.
Collapse
Affiliation(s)
- Wanyi Huang
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China
| | - Ziqi Zhang
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China
| | - Yueyang Qiu
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China
| | - Yuan Gao
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China,Department of Orthodontics, Shenyang Stomatological Hospital, Shenyang, China
| | - Yongqiang Fan
- College of Life and Health Sciences, Northeastern University, Shenyang, China,Shenyang National Laboratory for Materials Science, Northeastern University, Shenyang, China
| | - Qiang Wang
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China,*Correspondence: Qing Zhou, ; Qiang Wang,
| | - Qing Zhou
- School and Hospital of Stomatology, China Medical University, Shenyang, China,Liaoning Provincial Key Laboratory of Oral Diseases, China Medical University, Shenyang, China,*Correspondence: Qing Zhou, ; Qiang Wang,
| |
Collapse
|
20
|
Solechan S, Suprihanto A, Widyanto SA, Triyono J, Fitriyana DF, Siregar JP, Cionita T. Characterization of PLA/PCL/Nano-Hydroxyapatite (nHA) Biocomposites Prepared via Cold Isostatic Pressing. Polymers (Basel) 2023; 15:polym15030559. [PMID: 36771860 PMCID: PMC9919168 DOI: 10.3390/polym15030559] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/19/2023] [Accepted: 01/19/2023] [Indexed: 01/24/2023] Open
Abstract
Hydroxyapatite has the closest chemical composition to human bone. Despite this, the use of nano-hydroxyapatite (nHA) to produce biocomposite scaffolds from a mixture of polylactic acid (PLA) and polycaprolactone (PCL) using cold isostatic pressing has not been studied intensively. In this study, biocomposites were created employing nHA as an osteoconductive filler and a polymeric blend of PLA and PCL as a polymer matrix for prospective usage in the medical field. Cold isostatic pressing and subsequent sintering were used to create composites with different nHA concentrations that ranged from 0 to 30 weight percent. Using physical and mechanical characterization techniques such as Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and density, porosity, tensile, and flexural standard tests, it was determined how the nHA concentrations affected the biocomposite's general properties. In this study, the presence of PLA, PCL, and nHA was well identified using FTIR, XRD, and SEM methods. The biocomposites with high nHA content showed intense bands for symmetric stretching and the asymmetric bending vibration of PO43-. The incorporation of nHA into the polymeric blend matrix resulted in a rather irregular structure and the crystallization became more difficult. The addition of nHA improved the density and tensile and flexural strength of the PLA/PCL matrix (0% nHA). However, with increasing nHA content, the PLA/PCL/nHA biocomposites became more porous. In addition, the density, flexural strength, and tensile strength of the PLA/PCL/nHA biocomposites decreased with increasing nHA concentration. The PLA/PCL/nHA biocomposites with 10% nHA had the highest mechanical properties with a density of 1.39 g/cm3, a porosity of 1.93%, a flexural strength of 55.35 MPa, and a tensile strength of 30.68 MPa.
Collapse
Affiliation(s)
- Solechan Solechan
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang 50275, Indonesia
- Department of Mechanical Engineering, Universitas Muhammadiyah Semarang, Kampus Kasipah, Semarang 50254, Indonesia
- Correspondence:
| | - Agus Suprihanto
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang 50275, Indonesia
| | - Susilo Adi Widyanto
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang 50275, Indonesia
| | - Joko Triyono
- Department of Mechanical Engineering, Sebelas Maret University, Surakarta 57126, Indonesia
| | - Deni Fajar Fitriyana
- Department of Mechanical Engineering, Universitas Negeri Semarang, Kampus Sekaran, Gunungpati, Semarang 50229, Indonesia
| | - Januar Parlaungan Siregar
- Faculty of Mechanical & Automotive Engineering Technology, Universiti Malaysia Pahang, Pekan 26600, Malaysia
| | - Tezara Cionita
- Faculty of Engineering and Quantity Surveying, INTI International University, Nilai 71800, Malaysia
| |
Collapse
|
21
|
Nikolova MP, Apostolova MD. Advances in Multifunctional Bioactive Coatings for Metallic Bone Implants. MATERIALS (BASEL, SWITZERLAND) 2022; 16:183. [PMID: 36614523 PMCID: PMC9821663 DOI: 10.3390/ma16010183] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 12/19/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
To fix the bone in orthopedics, it is almost always necessary to use implants. Metals provide the needed physical and mechanical properties for load-bearing applications. Although widely used as biomedical materials for the replacement of hard tissue, metallic implants still confront challenges, among which the foremost is their low biocompatibility. Some of them also suffer from excessive wear, low corrosion resistance, infections and shielding stress. To address these issues, various coatings have been applied to enhance their in vitro and in vivo performance. When merged with the beneficial properties of various bio-ceramic or polymer coatings remarkable bioactive, osteogenic, antibacterial, or biodegradable composite implants can be created. In this review, bioactive and high-performance coatings for metallic bone implants are systematically reviewed and their biocompatibility is discussed. Updates in coating materials and formulations for metallic implants, as well as their production routes, have been provided. The ways of improving the bioactive coating performance by incorporating bioactive moieties such as growth factors, osteogenic factors, immunomodulatory factors, antibiotics, or other drugs that are locally released in a controlled manner have also been addressed.
Collapse
Affiliation(s)
- Maria P. Nikolova
- Department of Material Science and Technology, University of Ruse “A. Kanchev”, 8 Studentska Str., 7017 Ruse, Bulgaria
| | - Margarita D. Apostolova
- Medical and Biological Research Lab., “Roumen Tsanev” Institute of Molecular Biology, Bulgarian Academy of Sciences, 1113 Sofia, Bulgaria
| |
Collapse
|
22
|
Hricovíni M, Owens RJ, Bak A, Kozik V, Musiał W, Pierattelli R, Májeková M, Rodríguez Y, Musioł R, Slodek A, Štarha P, Piętak K, Słota D, Florkiewicz W, Sobczak-Kupiec A, Jampílek J. Chemistry towards Biology-Instruct: Snapshot. Int J Mol Sci 2022; 23:14815. [PMID: 36499140 PMCID: PMC9739621 DOI: 10.3390/ijms232314815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/15/2022] [Accepted: 11/23/2022] [Indexed: 12/05/2022] Open
Abstract
The knowledge of interactions between different molecules is undoubtedly the driving force of all contemporary biomedical and biological sciences. Chemical biology/biological chemistry has become an important multidisciplinary bridge connecting the perspectives of chemistry and biology to the study of small molecules/peptidomimetics and their interactions in biological systems. Advances in structural biology research, in particular linking atomic structure to molecular properties and cellular context, are essential for the sophisticated design of new medicines that exhibit a high degree of druggability and very importantly, druglikeness. The authors of this contribution are outstanding scientists in the field who provided a brief overview of their work, which is arranged from in silico investigation through the characterization of interactions of compounds with biomolecules to bioactive materials.
Collapse
Affiliation(s)
- Miloš Hricovíni
- Institute of Chemistry, Slovak Academy of Sciences, Dúbravská cesta 9, 845 38 Bratislava, Slovakia
| | - Raymond J. Owens
- Structural Biology, The Rosalind Franklin Institute, Harwell Science Campus, UK, University of Oxford, Oxford OX11 0QS, UK
- Division of Structural Biology, The Wellcome Centre for Human Genetics, University of Oxford, Oxford OX3 7BN, UK
| | - Andrzej Bak
- Institute of Chemistry, University of Silesia, Szkolna 9, 40 007 Katowice, Poland
| | - Violetta Kozik
- Institute of Chemistry, University of Silesia, Szkolna 9, 40 007 Katowice, Poland
| | - Witold Musiał
- Department of Physical Chemistry and Biophysics, Pharmaceutical Faculty, Wroclaw Medical University, Borowska 211A, 50 556 Wrocław, Poland
| | - Roberta Pierattelli
- Magnetic Resonance Center and Department of Chemistry “Ugo Schiff”, University of Florence, 50019 Sesto Fiorentino, Italy
| | - Magdaléna Májeková
- Center of Experimental Medicine SAS and Department of Biochemical Pharmacology, Institute of Experimental Pharmacology and Toxicology, Slovak Academy of Sciences, Dubravska cesta 9, 841 04 Bratislava, Slovakia
| | - Yoel Rodríguez
- Department of Natural Sciences, Eugenio María de Hostos Community College, City University of New York, 500 Grand Concourse, Bronx, NY 10451, USA
- Department of Pharmacological Sciences, Icahn School of Medicine at Mount Sinai, 1425 Madison Avenue, New York, NY 10029, USA
| | - Robert Musioł
- Institute of Chemistry, University of Silesia, Szkolna 9, 40 007 Katowice, Poland
| | - Aneta Slodek
- Institute of Chemistry, University of Silesia, Szkolna 9, 40 007 Katowice, Poland
| | - Pavel Štarha
- Department of Inorganic Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 1192/12, 771 46 Olomouc, Czech Republic
| | - Karina Piętak
- Department of Materials Science, Faculty of Materials Engineering and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31 864 Krakow, Poland
| | - Dagmara Słota
- Department of Materials Science, Faculty of Materials Engineering and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31 864 Krakow, Poland
| | - Wioletta Florkiewicz
- Department of Materials Science, Faculty of Materials Engineering and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31 864 Krakow, Poland
| | - Agnieszka Sobczak-Kupiec
- Department of Materials Science, Faculty of Materials Engineering and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31 864 Krakow, Poland
| | - Josef Jampílek
- Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Ilkovičova 6, 842 15 Bratislava, Slovakia
| |
Collapse
|
23
|
Biocompatibility of 3D-printed PLA, PEEK and PETG: Adhesion of Bone Marrow and Peritoneal Lavage Cells. Polymers (Basel) 2022; 14:polym14193958. [PMID: 36235903 PMCID: PMC9571806 DOI: 10.3390/polym14193958] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/11/2022] [Accepted: 09/17/2022] [Indexed: 11/28/2022] Open
Abstract
Samples in the form of cylindrical plates, additively manufactured using the fused deposition modelling (or filament freeform fabrication, FDM/FFF) technology from polylactide (PLA), polyethylene terephthalate glycol (PETG) and polyetheretherketone (PEEK), were studied in series of in-vitro experiments on the adhesion of rat bone-marrow cells and rat peritoneal cells. Methods of estimation of the absolute number of cells and polymer samples’ mass change were used for the evaluation of cells adhesion, followed by the evaluation of cell-culture supernatants. The results of experiments for both types of cells demonstrated a statistically significant change in the absolute number of cells (variation from 44 to 119%) and the weight of the polymer samples (variation from 0.61 to 2.18%), depending on roughness of sample surface, controlled by a nozzle diameter of a 3D printer as well as printing layer height. It was found that more cells adhere to PLA samples with a larger nozzle diameter and layer height. For PETG samples, the results did not show a clear relationship between cell adhesion and printing parameters. For PEEK samples, on the contrary, adhesion to samples printed with a lower nozzle diameter (higher resolution) is better than to samples printed with a larger nozzle diameter (lower resolution). The difference in results for various polymers can be explained by their chemical structure.
Collapse
|
24
|
Abstract
Bioactive coatings are widely used and understood materials in engineering [...]
Collapse
|