1
|
Ponce H, Gutiérrez S, Botero-Valencia J, Marquez-Viloria D, Castano-Londono L. An intelligent climate monitoring system for hygrothermal virtual measurement in closed buildings using Internet-of-things and artificial hydrocarbon networks. Heliyon 2024; 10:e31716. [PMID: 38828295 PMCID: PMC11140809 DOI: 10.1016/j.heliyon.2024.e31716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Revised: 04/30/2024] [Accepted: 05/21/2024] [Indexed: 06/05/2024] Open
Abstract
Studies analyzing indoor thermal environments comprising temperature and humidity may be insufficient when obtaining data from sensors, which may be susceptible to inaccurate or failed information from internal and external factors. Therefore, this study proposes an intelligent climate monitoring using a supervised learning method for virtual hygrothermal measurement in enclosed buildings used to predict temperature and relative humidity when a sensor failure is detected. The methodology comprises the data collection from a wireless sensor network, the building of the learning model for predicting the dynamics of environmental variables, and the implementation of a sensor failure detection model. We use an artificial hydrocarbon network as the learning model for their simplicity and effectiveness under uncertain and noisy data. The experiments use data acquired in two settings: (1) a laboratory office and (2) a museum storage room. The first scenario has multiple workstations, and the staff turns on or off the air conditioning depending on the feeling of comfort, generating an uncontrolled environment for the variables of interest. The second scenario has controlled temperature and humidity to ensure the conservation conditions of the museum pieces. Both scenarios used 12 sensors that acquired data for one month, providing an average of 58,300 values for each variable. Results of the proposed methodology provide 95% of accuracy in terms of sensor failure detection and identification, and less than 0.22% of tolerance variability in temperature and humidity after sensor accommodation in both scenarios.
Collapse
Affiliation(s)
- Hiram Ponce
- Universidad Panamericana, Facultad de Ingeniería, Augusto Rodin 498, Ciudad de México, 03920, Mexico
| | - Sebastián Gutiérrez
- TECNUN Escuela de Ingeniería, Universidad de Navarra, Manuel Lardizabal 13, San Sebastián, 20018, Spain
| | - Juan Botero-Valencia
- Facultad de Ingenierías, Instituto Tecnológico Metropolitano, Calle 73 No. 76A-354, Medellin, 050034, Colombia
| | - David Marquez-Viloria
- Facultad de Ingenierías, Instituto Tecnológico Metropolitano, Calle 73 No. 76A-354, Medellin, 050034, Colombia
| | - Luis Castano-Londono
- Facultad de Ingeniería, Universidad de Antioquia, Calle 70 No. 52-21, Medellin, 050010, Colombia
| |
Collapse
|
2
|
Pietraru RN, Olteanu A, Adochiei IR, Adochiei FC. Reengineering Indoor Air Quality Monitoring Systems to Improve End-User Experience. SENSORS (BASEL, SWITZERLAND) 2024; 24:2659. [PMID: 38676280 PMCID: PMC11055101 DOI: 10.3390/s24082659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 04/19/2024] [Accepted: 04/20/2024] [Indexed: 04/28/2024]
Abstract
This paper presents an indoor air quality (IAQ) monitoring system designed for a better end-user experience. The monitoring system consists of elements, from the monitoring sensor to the monitoring interface, designed and implemented by the research team, especially for the proposed monitoring system. The monitoring solution is intended for users who live in houses without automatic ventilation systems. The air quality sensor is designed at a minimum cost and complexity to allow multi-zone implementation without significant effort. The user interface uses a spatial graphic representation that facilitates understanding areas with different air quality levels. Presentation of the outdoor air quality level supports the user's decision to ventilate a space. An innovative element of the proposed monitoring interface is the real-time forecast of air quality evolution in each monitored space. The paper describes the implementation of an original monitoring solution (monitoring device, Edge/Cloud management system, innovative user monitoring interface) and presents the results of testing this system in a relevant environment. The research conclusions show the proposed solution's benefits in improving the end-user experience, justified both by the technical results obtained and by the opinion of the users who tested the monitoring system.
Collapse
Affiliation(s)
- Radu Nicolae Pietraru
- Faculty of Automatic Control and Computers, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania;
| | - Adriana Olteanu
- Faculty of Automatic Control and Computers, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania;
| | - Ioana-Raluca Adochiei
- Emil Palade Center of Excellence for Young Researchers, Academy of Romanian Scientists, Ilfov 3, 050044 Bucharest, Romania; (I.-R.A.); (F.-C.A.)
- Faculty of Electrical Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
| | - Felix-Constantin Adochiei
- Emil Palade Center of Excellence for Young Researchers, Academy of Romanian Scientists, Ilfov 3, 050044 Bucharest, Romania; (I.-R.A.); (F.-C.A.)
- Faculty of Electrical Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
| |
Collapse
|
3
|
Dong D, Feng H. Design and use of a wireless temperature measurement network system integrating artificial intelligence and blockchain in electrical power engineering. PLoS One 2024; 19:e0296398. [PMID: 38165871 PMCID: PMC10760662 DOI: 10.1371/journal.pone.0296398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 12/12/2023] [Indexed: 01/04/2024] Open
Abstract
This work aims to investigate the potential fire hazard stemming from the overheating of power equipment. The advent of the artificial intelligence era has facilitated the fusion of blockchain and Internet of Things (IoT) technologies. This work delves into the technical standards for IoT equipment monitoring and smart grid communication, and the IoT environment of power grid equipment. This work introduces a temperature monitoring network tailored for IoT wireless power equipment suitable for the power environment, and conducts system debugging in the power laboratory. The findings affirm that the temperature out-of-limit alarm testing has met the required criteria, confirming the system's ability to issue timely warnings when temperatures breach a predefined threshold, effectively avoiding high-temperature misfires. This work fully harnesses the secure and user-friendly operation of smart blockchain and the wireless sensing technology of the IoT to realize online monitoring and remote temperature measurement of the power system. It can effectively prevent equipment from overheating and damage, and promote the development of equipment condition monitoring technology in electric power engineering.
Collapse
|
4
|
Wang J, Du W, Lei Y, Chen Y, Wang Z, Mao K, Tao S, Pan B. Quantifying the dynamic characteristics of indoor air pollution using real-time sensors: Current status and future implication. ENVIRONMENT INTERNATIONAL 2023; 175:107934. [PMID: 37086491 DOI: 10.1016/j.envint.2023.107934] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/12/2023] [Accepted: 04/12/2023] [Indexed: 05/03/2023]
Abstract
People generally spend most of their time indoors, making indoor air quality be of great significance to human health. Large spatiotemporal heterogeneity of indoor air pollution can be hardly captured by conventional filter-based monitoring but real-time monitoring. Real-time monitoring is conducive to change air assessment mode from static and sparse analysis to dynamic and massive analysis, and has made remarkable strides in indoor air evaluation. In this review, the state of art, strengths, challenges, and further development of real-time sensors used in indoor air evaluation are focused on. Researches using real-time sensors for indoor air evaluation have increased rapidly since 2018, and are mainly conducted in China and the USA, with the most frequently investigated air pollutants of PM2.5. In addition to high spatiotemporal resolution, real-time sensors for indoor air evaluation have prominent advantages in 3-dimensional monitoring, pollution peak and source identification, and short-term health effect evaluation. Huge amounts of data from real-time sensors also facilitate the modeling and prediction of indoor air pollution. However, challenges still remain in extensive deployment of real-time sensors indoors, including the selection, performance, stability, as well as calibration of sensors. In future, sensors with high performance, long-term stability, low price, and low energy consumption are welcomed. Furthermore, more target air pollutants are also expected to be detected simultaneously by real-time sensors in indoor air monitoring.
Collapse
Affiliation(s)
- Jinze Wang
- Key Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China
| | - Wei Du
- Yunnan Provincial Key Laboratory of Soil Carbon Sequestration and Pollution Control, Faculty of Environmental Science & Engineering, Kunming University of Science & Technology, Kunming 650500, China.
| | - Yali Lei
- Key Laboratory of Geographic Information Science of the Ministry of Education, School of Geographic Sciences, East China Normal University, Shanghai 200241, China
| | - Yuanchen Chen
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, Zhejiang 310032, China
| | - Zhenglu Wang
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China
| | - Kang Mao
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, China
| | - Shu Tao
- Key Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China
| | - Bo Pan
- Yunnan Provincial Key Laboratory of Soil Carbon Sequestration and Pollution Control, Faculty of Environmental Science & Engineering, Kunming University of Science & Technology, Kunming 650500, China
| |
Collapse
|
5
|
Vanhaeverbeke J, Deprost E, Bonte P, Strobbe M, Nelis J, Volckaert B, Ongenae F, Verstockt S, Van Hoecke S. Real-Time Estimation and Monitoring of COVID-19 Aerosol Transmission Risk in Office Buildings. SENSORS (BASEL, SWITZERLAND) 2023; 23:2459. [PMID: 36904663 PMCID: PMC10007635 DOI: 10.3390/s23052459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/10/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
A healthy and safe indoor environment is an important part of containing the coronavirus disease 2019 (COVID-19) pandemic. Therefore, this work presents a real-time Internet of things (IoT) software architecture to automatically calculate and visualize a COVID-19 aerosol transmission risk estimation. This risk estimation is based on indoor climate sensor data, such as carbon dioxide (CO2) and temperature, which is fed into Streaming MASSIF, a semantic stream processing platform, to perform the computations. The results are visualized on a dynamic dashboard that automatically suggests appropriate visualizations based on the semantics of the data. To evaluate the complete architecture, the indoor climate during the student examination periods of January 2020 (pre-COVID) and January 2021 (mid-COVID) was analyzed. When compared to each other, we observe that the COVID-19 measures in 2021 resulted in a safer indoor environment.
Collapse
|
6
|
Komary M, Komarizadehasl S, Tošić N, Segura I, Lozano-Galant JA, Turmo J. Low-Cost Technologies Used in Corrosion Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:1309. [PMID: 36772348 PMCID: PMC9920423 DOI: 10.3390/s23031309] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/17/2023] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
Globally, corrosion is the costliest cause of the deterioration of metallic and concrete structures, leading to significant financial losses and unexpected loss of life. Therefore, corrosion monitoring is vital to the assessment of structures' residual performance and for the identification of pathologies in early stages for the predictive maintenance of facilities. However, the high price tag on available corrosion monitoring systems leads to their exclusive use for structural health monitoring applications, especially for atmospheric corrosion detection in civil structures. In this paper a systematic literature review is provided on the state-of-the-art electrochemical methods and physical methods used so far for corrosion monitoring compatible with low-cost sensors and data acquisition devices for metallic and concrete structures. In addition, special attention is paid to the use of these devices for corrosion monitoring and detection for in situ applications in different industries. This analysis demonstrates the possible applications of low-cost sensors in the corrosion monitoring sector. In addition, this study provides scholars with preferred techniques and the most common microcontrollers, such as Arduino, to overcome the corrosion monitoring difficulties in the construction industry.
Collapse
Affiliation(s)
- Mahyad Komary
- Department of Civil and Environment Engineering, Universitat Politècnica de Catalunya, BarcelonaTech. C/ Jordi Girona 1-3, 08034 Barcelona, Spain
| | - Seyedmilad Komarizadehasl
- Department of Civil and Environment Engineering, Universitat Politècnica de Catalunya, BarcelonaTech. C/ Jordi Girona 1-3, 08034 Barcelona, Spain
| | - Nikola Tošić
- Department of Civil and Environment Engineering, Universitat Politècnica de Catalunya, BarcelonaTech. C/ Jordi Girona 1-3, 08034 Barcelona, Spain
| | - I. Segura
- Department of Civil and Environment Engineering, Universitat Politècnica de Catalunya, BarcelonaTech. C/ Jordi Girona 1-3, 08034 Barcelona, Spain
| | - Jose Antonio Lozano-Galant
- Department of Civil Engineering, Universidad de Castilla-La Mancha, Av. Camilo Jose Cela s/n, 13071 Ciudad Real, Spain
| | - Jose Turmo
- Department of Civil and Environment Engineering, Universitat Politècnica de Catalunya, BarcelonaTech. C/ Jordi Girona 1-3, 08034 Barcelona, Spain
| |
Collapse
|
7
|
Air quality measurement, prediction and warning using transfer learning based IOT system for ambient assisted living. INTERNATIONAL JOURNAL OF PERVASIVE COMPUTING AND COMMUNICATIONS 2023. [DOI: 10.1108/ijpcc-07-2022-0271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Purpose
Indoor air quality monitoring is extremely important in urban, industrial areas. Considering the devastating effect of declining quality of air in major part of the countries like India and China, it is highly recommended to monitor the quality of air which can help people with respiratory diseases, children and elderly people to take necessary precautions and stay safe at their homes. The purpose of this study is to detect air quality and perform predictions which could be part of smart home automation with the use of newer technology.
Design/methodology/approach
This study proposes an Internet-of-Things (IoT)-based air quality measurement, warning and prediction system for ambient assisted living. The proposed ambient assisted living system consists of low-cost air quality sensors and ESP32 controller with new generation embedded system architecture. It can detect Indoor Air Quality parameters like CO, PM2.5, NO2, O3, NH3, temperature, pressure, humidity, etc. The low cost sensor data are calibrated using machine learning techniques for performance improvement. The system has a novel prediction model, multiheaded convolutional neural networks-gated recurrent unit which can detect next hour pollution concentration. The model uses a transfer learning (TL) approach for prediction when the system is new and less data available for prediction. Any neighboring site data can be used to transfer knowledge for early predictions for the new system. It can have a mobile-based application which can send warning notifications to users if the Indoor Air Quality parameters exceed the specified threshold values. This is all required to take necessary measures against bad air quality.
Findings
The IoT-based system has implemented the TL framework, and the results of this study showed that the system works efficiently with performance improvement of 55.42% in RMSE scores for prediction at new target system with insufficient data.
Originality/value
This study demonstrates the implementation of an IoT system which uses low-cost sensors and deep learning model for predicting pollution concentration. The system is tackling the issues of the low-cost sensors for better performance. The novel approach of pretrained models and TL work very well at the new system having data insufficiency issues. This study contributes significantly with the usage of low-cost sensors, open-source advanced technology and performance improvement in prediction ability at new systems. Experimental results and findings are disclosed in this study. This will help install multiple new cost-effective monitoring stations in smart city for pollution forecasting.
Collapse
|
8
|
Ilieș A, Caciora T, Marcu F, Berdenov Z, Ilieș G, Safarov B, Hodor N, Grama V, Shomali MAA, Ilies DC, Gaceu O, Costea M, Kieti D. Analysis of the Interior Microclimate in Art Nouveau Heritage Buildings for the Protection of Exhibits and Human Health. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:16599. [PMID: 36554480 PMCID: PMC9779619 DOI: 10.3390/ijerph192416599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/04/2022] [Accepted: 12/05/2022] [Indexed: 06/17/2023]
Abstract
Poor air quality inside museums can have a double effect; on the one hand, influencing the integrity of the exhibits and on the other hand, endangering the health of employees and visitors. Both components can be very sensitive to the influence of the internal microclimate, therefore careful monitoring of the physical parameters and pollutants is required in order to maintain them within strict limits and thus to reduce the hazards that can be induced. The current study considers the determination and analysis of 15 indicators of the internal microclimate in an Art Nouveau museum built at the beginning of the 20th century in the Municipality of Oradea, Romania. The monitoring spanned a period of seven months, between September 2021 and March 2022, targeting three rooms of the museum with different characteristics and containing exhibits with a high degree of fragility. The results show that, although there are numerous indicators that have exceeded the thresholds induced by international standards, the possible negative impact on the exhibits and/or on human health remains moderate. This is due to the fact that, most of the time, exceeding the permitted limits are small or only sporadic, the values quickly returning to the permitted limits. Thus, only 22 of the 212 days of monitoring recorded marginal conditions regarding the quality of the indoor air, the rest having acceptable and good conditions. To improve the indoor conditions, a more careful management is needed, especially regarding the values of temperature, humidity, particulate matters, natural and artificial light, volatile organic compounds (VOC) and formaldehyde (HCHO), which during the measurements recorded high values that fluctuated in a wide spectrum. The obtained results can represent the basis for the development and implementation of long-term strategies for stabilizing the microclimatic conditions in the museum in order to preserve the exhibits preventively and to ensure a clean and safe environment for people.
Collapse
Affiliation(s)
- Alexandru Ilieș
- Department of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania
| | - Tudor Caciora
- Department of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania
| | - Florin Marcu
- Faculty of Medicine and Pharmacy, University of Oradea, 10 Piata, 1 Decembrie Street, 410073 Oradea, Romania
| | - Zharas Berdenov
- Faculty of Science, L.N. Gumilyov Eurasian National University, 2 Satpayev Street, Nur-Sultan 010008, Kazakhstan
| | - Gabriela Ilieș
- Faculty of Geography, Babes-Bolyai University, Sighetu Marmatiei Extension, 6 Avram Iancu Street, 435500 Sighetu Marmatiei, Romania
| | - Bahodirhon Safarov
- Department of Digital Economy, Samarkand State University, Samarkand 140104, Uzbekistan
| | - Nicolaie Hodor
- Faculty of Geography, Babes-Bolyai University, 5-6 Clinicilor Street, 400006 Cluj-Napoca, Romania
| | - Vasile Grama
- Department of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania
| | - Maisa Ali Al Shomali
- Faculty of Engineering, Al-Balqa Applied University, P.O. Box 15008, Marka 11134, Jordan
| | - Dorina Camelia Ilies
- Department of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania
| | - Ovidiu Gaceu
- Department of Geography, Tourism and Territorial Planning, Faculty of Geography, Tourism and Sport, University of Oradea, 1 Universitatii Street, 410087 Oradea, Romania
| | - Monica Costea
- Faculty of Environmental Protection, University of Oradea, Gen Magheru Street, 410048 Oradea, Romania
| | - Damiannah Kieti
- School of Tourism, Hospitality & Events Management, Department of Tourism, Moi University, Kesses, Eldoret 3900-30100, Kenya
| |
Collapse
|
9
|
Rodríguez-Vidal I, Martín-Garín A, González-Quintial F, Rico-Martínez JM, Hernández-Minguillón RJ, Otaegi J. Response to the COVID-19 Pandemic in Classrooms at the University of the Basque Country through a User-Informed Natural Ventilation Demonstrator. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:14560. [PMID: 36361439 PMCID: PMC9658559 DOI: 10.3390/ijerph192114560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/30/2022] [Accepted: 11/04/2022] [Indexed: 06/16/2023]
Abstract
The COVID-19 pandemic has generated a renewed interest in indoor air quality to limit viral spread. In the case of educational spaces, due to the high concentration of people and the fact that most of the existing buildings do not have any mechanical ventilation system, the different administrations have established natural ventilation protocols to guarantee an air quality that reduces risk of contagion by the SARS-CoV-2 virus after the return to the classrooms. Many of the initial protocols established a ventilation pattern that opted for continuous or intermittent ventilation to varying degrees of intensity. This study, carried out on a university campus in Spain, analyses the performance of natural ventilation activated through the information provided by monitoring and visualisation of real-time data. In order to carry out this analysis, a experiment was set up where a preliminary study of ventilation without providing information to the users was carried out, which was then compared with the result of providing live feedback to the occupants of two classrooms and an administration office in different periods of 2020, 2021 and 2022. In the administration office, a CO2-concentration-based method was applied retrospectively to assess the risk of airborne infection. This experience has served as a basis to establish a route for user-informed improvement of air quality in educational spaces in general through low-cost systems that allow a rational use of natural ventilation while helping maintain an adequate compromise between IAQ, comfort and energy consumption, without having to resort to mechanical ventilation systems.
Collapse
Affiliation(s)
| | | | | | | | | | - Jorge Otaegi
- CAVIAR Research Group, Department of Architecture, University of the Basque Country UPV/EHU, Plaza Oñati, 2, 20018 Donostia-San Sebastián, Spain
| |
Collapse
|
10
|
Himeur Y, Elnour M, Fadli F, Meskin N, Petri I, Rezgui Y, Bensaali F, Amira A. AI-big data analytics for building automation and management systems: a survey, actual challenges and future perspectives. Artif Intell Rev 2022; 56:4929-5021. [PMID: 36268476 PMCID: PMC9568938 DOI: 10.1007/s10462-022-10286-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In theory, building automation and management systems (BAMSs) can provide all the components and functionalities required for analyzing and operating buildings. However, in reality, these systems can only ensure the control of heating ventilation and air conditioning system systems. Therefore, many other tasks are left to the operator, e.g. evaluating buildings’ performance, detecting abnormal energy consumption, identifying the changes needed to improve efficiency, ensuring the security and privacy of end-users, etc. To that end, there has been a movement for developing artificial intelligence (AI) big data analytic tools as they offer various new and tailor-made solutions that are incredibly appropriate for practical buildings’ management. Typically, they can help the operator in (i) analyzing the tons of connected equipment data; and; (ii) making intelligent, efficient, and on-time decisions to improve the buildings’ performance. This paper presents a comprehensive systematic survey on using AI-big data analytics in BAMSs. It covers various AI-based tasks, e.g. load forecasting, water management, indoor environmental quality monitoring, occupancy detection, etc. The first part of this paper adopts a well-designed taxonomy to overview existing frameworks. A comprehensive review is conducted about different aspects, including the learning process, building environment, computing platforms, and application scenario. Moving on, a critical discussion is performed to identify current challenges. The second part aims at providing the reader with insights into the real-world application of AI-big data analytics. Thus, three case studies that demonstrate the use of AI-big data analytics in BAMSs are presented, focusing on energy anomaly detection in residential and office buildings and energy and performance optimization in sports facilities. Lastly, future directions and valuable recommendations are identified to improve the performance and reliability of BAMSs in intelligent buildings.
Collapse
|
11
|
Garcés HO, Durán C, Espinosa E, Jerez A, Palominos F, Hinojosa M, Carrasco R. Monitoring of Thermal Comfort and Air Quality for Sustainable Energy Management inside Hospitals Based on Online Analytical Processing and the Internet of Things. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12207. [PMID: 36231507 PMCID: PMC9565032 DOI: 10.3390/ijerph191912207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/17/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
There is a need to ensure comfortable conditions for hospital staff and patients from the point of view of thermal comfort and air quality so that they do not affect their performance. We consider the need for hospital employees and patients to enjoy conditions of greater well-being during their stay. This is understood as a comfortable thermal sensation and adequate air quality, depending on the task they are performing. The contribution of this article is the formulation of the fundamentals of a system and platform for monitoring thermal comfort and Indoor Air Quality (IAQ) in hospitals, based on an Internet of Things platform composed of a low-cost sensor node network that is capable of measuring critical variables such as humidity, temperature, and Carbon Dioxide (CO2). As part of the platform, a multidimensional data model with an On-Line Analytical Processing (OLAP) approach is presented that offers query flexibility, data volume reduction, as well as a significant reduction in query response times. The experimental results confirm the suitability of the platform's data model, which facilitates operational and strategic decision making in complex hospitals.
Collapse
Affiliation(s)
- Hugo O. Garcés
- Departamento Ingeniería Informática, Universidad Católica de la Santísima Concepción, Concepción 4090541, Chile
| | - Claudia Durán
- Departamento de Ingeniería Industrial, Facultad Ingeniería, Universidad Tecnológica Metropolitana, Santiago 7800002, Chile
| | - Eduardo Espinosa
- Department of Electrical Engineering, Faculty of Engineering, Universidad Católica de la Santísima Concepción, Concepción 4090541, Chile
| | | | - Fredi Palominos
- Departamento de Matemática y Ciencias de la Computación, Universidad de Santiago de Chile, Santiago 9170022, Chile
| | - Marcela Hinojosa
- Departamento de Tecnología Médica, Facultad de Medicina, Universidad de Concepción, Concepción 4070409, Chile
| | - Raúl Carrasco
- Facultad de Ingeniería y Negocios, Universidad de Las Américas, Santiago 7500975, Chile
| |
Collapse
|
12
|
A Novel Data Acquisition System for Obtaining Thermal Parameters of Building Envelopes. BUILDINGS 2022. [DOI: 10.3390/buildings12050670] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Owing to the high energy consumption in the building sector, appraising the thermal performance of building envelopes is an increasing concern. Recently, a few in situ methodologies to diagnose the thermal parameters of buildings have been considered. However, because of their limitations such as low accuracy, limited number of measurements, and the high cost of monitoring devices, researchers are seeking a new alternative. In this study, a novel hyper-efficient Arduino transmittance-meter was introduced to overcome these limitations and determine the thermal parameters of building envelopes. Unlike conventional methodologies, the proposed transmittance-meter is based on synchronized measurements of different parameters necessary to estimate the transmittance parameter. To verify the applicability of the transmittance-meter, an experimental study was conducted wherein a temperature-controlled box model was thermally monitored, and the outputs of the transmittance-meter employed were compared with those captured by a commercial device. The results revealed a high level of reduction in cost and a low range of difference compared with the latter, thereby validating the applicability of the proposed thermal monitoring system.
Collapse
|
13
|
Use of Low-Cost Devices for the Control and Monitoring of CO2 Concentration in Existing Buildings after the COVID Era. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083927] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
In the COVID-19 era, a direct relationship has been consolidated between the concentration of the pollutant carbon dioxide (CO2) and indoor disease transmission. For reducing its spread, recommendations have been established among which air renewal is a key element to improve indoor air quality (IAQ). In this study, a low-cost CO2 measurement device was designed, developed, assembled, prototyped, and openly programmed so that the IAQ can be monitored remotely. In addition, this clonic device was calibrated for correct data acquisition. In parallel, computational fluid dynamics (CFD) modeling analysis was used to study the indoor air flows to eliminate non-representative singular measurement points, providing possible locations. The results in four scenarios (cross ventilation, outdoor ventilation, indoor ventilation, and no ventilation) showed that the measurements provided by the clonic device are comparable to those obtained by laboratory instruments, with an average error of less than 3%. These data collected wirelessly for interpretation were evaluated on an Internet of Things (IoT) platform in real time or deferred. As a result, remaining lifespan of buildings can be exploited interconnecting IAQ devices with other systems (as HVAC systems) in an IoT environment. This can transform them into smart buildings, adding value to their refurbishment and modernization.
Collapse
|
14
|
Scalable IoT Architecture for Monitoring IEQ Conditions in Public and Private Buildings. ENERGIES 2022. [DOI: 10.3390/en15062270] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This paper presents a scalable IoT architecture based on the edge–fog–cloud paradigm for monitoring the Indoor Environmental Quality (IEQ) parameters in public buildings. Nowadays, IEQ monitoring systems are becoming important for several reasons: (1) to ensure that temperature and humidity conditions are adequate, improving the comfort and productivity of the occupants; (2) to introduce actions to reduce energy consumption, contributing to achieving the Sustainable Development Goals (SDG); and (3) to guarantee the quality of the air—a key concern due to the COVID-19 worldwide pandemic. Two kinds of nodes compose the proposed architecture; these are the so-called: (1) smart IEQ sensor nodes, responsible for acquiring indoor environmental measures locally, and (2) the IEQ concentrators, responsible for collecting the data from smart sensor nodes distributed along the facilities. The IEQ concentrators are also responsible for configuring the acquisition system locally, logging the acquired local data, analyzing the information, and connecting to cloud applications. The presented architecture has been designed using low-cost open-source hardware and software—specifically, single board computers and microcontrollers such as Raspberry Pis and Arduino boards. WiFi and TCP/IP communication technologies were selected, since they are typically available in corporative buildings, benefiting from already available communication infrastructures. The application layer was implemented with MQTT. A prototype was built and deployed at the Faculty of Engineering of Vitoria-Gasteiz, University of the Basque Country (UPV/EHU), using the existing network infrastructure. This prototype allowed for collecting data within different academic scenarios. Finally, a smart sensor node was designed including low-cost sensors to measure temperature, humidity, eCO2, and VOC.
Collapse
|
15
|
Design and Development of Internet of Things-Driven Fault Detection of Indoor Thermal Comfort: HVAC System Problems Case Study. SENSORS 2022; 22:s22051925. [PMID: 35271075 PMCID: PMC8914663 DOI: 10.3390/s22051925] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 02/25/2022] [Accepted: 02/27/2022] [Indexed: 02/01/2023]
Abstract
Controlling thermal comfort in the indoor environment demands research because it is fundamental to indicating occupants’ health, wellbeing, and performance in working productivity. A suitable thermal comfort must monitor and balance complex factors from heating, ventilation, air-conditioning systems (HVAC Systems) and outdoor and indoor environments based on advanced technology. It needs engineers and technicians to observe relevant factors on a physical site and to detect problems using their experience to fix them early and prevent them from worsening. However, it is a labor-intensive and time-consuming task, while experts are short on diagnosing and producing proactive plans and actions. This research addresses the limitations by proposing a new Internet of Things (IoT)-driven fault detection system for indoor thermal comfort. We focus on the well-known problem caused by an HVAC system that cannot transfer heat from the indoor to outdoor and needs engineers to diagnose such concerns. The IoT device is developed to observe perceptual information from the physical site as a system input. The prior knowledge from existing research and experts is encoded to help systems detect problems in the manner of human-like intelligence. Three standard categories of machine learning (ML) based on geometry, probability, and logical expression are applied to the system for learning HVAC system problems. The results report that the MLs could improve overall performance based on prior knowledge around 10% compared to perceptual information. Well-designed IoT devices with prior knowledge reduced false positives and false negatives in the predictive process that aids the system to reach satisfactory performance.
Collapse
|
16
|
Museal Indoor Air Quality and Public Health: An Integrated Approach for Exhibits Preservation and Ensuring Human Health. SUSTAINABILITY 2022. [DOI: 10.3390/su14042462] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The quality of the indoor microclimate in museums is a problem of great interest to the contemporary society, given that it is in close connection with the health and comfort of visitors and employees, as well as with the integrity of the exhibits. Taking into account the fact that museums are places that have a special role in the community’s life and therefore attract a very large number of visitors of all ages, a very important issue is to determine the degree of safety that the indoor microclimate presents. Thus, the quality of the indoor microclimate was investigated inside an iconic museum in Romania, dating back to the 19th century, because pollutants from external or internal sources of the building, generated secondary, often anthropogenic, as a tendency to defend/adapt to climate change (CC), contribute to both local and regional pollution, but also lead to challenges in identifying links between air quality (AQ) and and climate change (CC). The methodology used was based on monitoring the main parameters of the microclimate (temperature, relative humidity and CO2) over a period of between October 2020 and March 2021, 21 weeks, as well as on determining the microbiological contamination of the air and some indoor exhibits located in three different areas of the museum. At the same time, the study aims to identify cheap, easy to implement and non-invasive solutions for removing fungi identified on exhibits for long-term preservation and reducing the risk of various pathologies in humans following prolonged exposure. The results obtained show that the indoor microclimate in the old heritage building favours the development of fungi, which have a high degree of contamination of the air (over 800 CFU/m3) and of the exhibits, representing a potential risk for the health of the visitors and museum workers. Thus, six species of yeast and five different fungi genera were identified in the air, while on the exhibits were individualised six fungi genera, a species of yeast and a bacterium. The most viable solution for cleaning materials, prolonging their lifespan and reducing the risk of disease in humans was represented by the use of essential oils (EO). Three essential oils (lavender, mint and lemon) were applied on an exhibit with five different microorganism genera, and it was observed that they have the ability to inhibit the spores from moulds and bacteria, being a very good alternative to the usual chemical treatments that are used in the cultural heritage field.
Collapse
|
17
|
Kuncoro CBD, Asyikin MBZ, Amaris A. Smart-Autonomous Wireless Volatile Organic Compounds Sensor Node for Indoor Air Quality Monitoring Application. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:2439. [PMID: 35206627 PMCID: PMC8875527 DOI: 10.3390/ijerph19042439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/10/2022] [Accepted: 02/18/2022] [Indexed: 12/10/2022]
Abstract
Several studies reported the significant effect of indoor air quality on human health, safety, productivity, and comfort because most humans usually conduct 80%-90% of their activity inside the building. This is generally due to the fact that indoor pollution is associated with volatile organic compounds (VOCs), pollutants with chronic health effects, both non-carcinogenic and carcinogenic, on humans. Therefore, this study focused on developing wireless VOCs sensor nodes with a low-power strategy feature to perform an autonomous operation in indoor air quality monitoring (IAQM). The sensor node mainboard consists of a microcontroller-based AVR (ATmega-4808) that supports a low power mode and low-power IAQ-Core sensor for VOCs detection. The low-power sensing algorithm developed also allowed the sensor node to consume a total power of 0.22 mAh for one cycle of operation, which includes the initial process, TVOCs value reading process, data transmitting process, and low power mode process at a time interval of 30 min. The most significant power was observed to be consumed in the data transmitting process with 0.13 mAh or 58% of total power consumption in one cycle of sensor node operation. Furthermore, the 10F capacitance of the supercapacitor was able to drive the VOCs sensor node for 139 s and it was recommended that further studies use micro energy harvesting (from an indoor environment) to extend its lifetime. The 1541-minute field experiment conducted also showed that TVOCs and CO2 values were successfully measured and displayed over an internet connection on the monitoring terminal dashboard. The recorded real-time TVOCs value of 175 ppb (<200 ppb) indicates good air quality.
Collapse
Affiliation(s)
- C. Bambang Dwi Kuncoro
- Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan;
| | - Moch Bilal Zaenal Asyikin
- Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan;
| | - Aurelia Amaris
- Department of Informatics Engineering, Faculty of Computer Science, Universitas Brawijaya, Malang 65145, Indonesia;
| |
Collapse
|
18
|
Abstract
Indoor Air Quality monitoring is a major asset to improving quality of life and building management. Today, the evolution of embedded technologies allows the implementation of such monitoring on the edge of the network. However, several concerns need to be addressed related to data security and privacy, routing and sink placement optimization, protection from external monitoring, and distributed data mining. In this paper, we describe an integrated framework that features distributed storage, blockchain-based Role-based Access Control, onion routing, routing and sink placement optimization, and distributed data mining to answer these concerns. We describe the organization of our contribution and show its relevance with simulations and experiments over a set of use cases.
Collapse
|
19
|
Saini J, Dutta M, Marques G. A novel application of fuzzy inference system optimized with particle swarm optimization and genetic algorithm for PM10 prediction. Soft comput 2022. [DOI: 10.1007/s00500-022-06777-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
20
|
Saini J, Dutta M, Marques G. ADFIST: Adaptive Dynamic Fuzzy Inference System Tree Driven by Optimized Knowledge Base for Indoor Air Quality Assessment. SENSORS 2022; 22:s22031008. [PMID: 35161754 PMCID: PMC8838659 DOI: 10.3390/s22031008] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 01/22/2022] [Accepted: 01/25/2022] [Indexed: 01/27/2023]
Abstract
Air quality levels do not just affect climate change; rather, it leaves a significant impact on public health and wellbeing. Indoor air pollution is the major contributor to increased mortality and morbidity rates. This paper is focused on the assessment of indoor air quality based on several important pollutants (PM10, PM2.5, CO2, CO, tVOC, and NO2). These pollutants are responsible for potential health issues, including respiratory disease, central nervous system dysfunction, cardiovascular disease, and cancer. The pollutant concentrations were measured from a rural site in India using an Internet of Things-based sensor system. An Adaptive Dynamic Fuzzy Inference System Tree was implemented to process the field variables. The knowledge base for the proposed model was designed using a global optimization algorithm. However, the model was tuned using a local search algorithm to achieve enhanced prediction performance. The proposed model gives normalized root mean square error of 0.6679, 0.6218, 0.1077, 0.2585, 0.0667 and 0.0635 for PM10, PM2.5, CO2, CO, tVOC, and NO2, respectively. This approach was compared with the existing studies in the literature, and the approach was also validated against the online benchmark dataset.
Collapse
Affiliation(s)
- Jagriti Saini
- National Institute of Technical Teacher’s Training and Research, Chandigarh 160019, India;
- Correspondence: (J.S.); (G.M.)
| | - Maitreyee Dutta
- National Institute of Technical Teacher’s Training and Research, Chandigarh 160019, India;
| | - Gonçalo Marques
- ESTGOH, Polytechnic of Coimbra, Rua General Santos Costa, 3400-124 Oliveira do Hospital, Portugal
- Correspondence: (J.S.); (G.M.)
| |
Collapse
|
21
|
Lung SCC, Thi Hien T, Cambaliza MOL, Hlaing OMT, Oanh NTK, Latif MT, Lestari P, Salam A, Lee SY, Wang WCV, Tsou MCM, Cong-Thanh T, Cruz MT, Tantrakarnapa K, Othman M, Roy S, Dang TN, Agustian D. Research Priorities of Applying Low-Cost PM 2.5 Sensors in Southeast Asian Countries. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19031522. [PMID: 35162543 PMCID: PMC8835170 DOI: 10.3390/ijerph19031522] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/24/2022] [Accepted: 01/26/2022] [Indexed: 12/19/2022]
Abstract
The low-cost and easy-to-use nature of rapidly developed PM2.5 sensors provide an opportunity to bring breakthroughs in PM2.5 research to resource-limited countries in Southeast Asia (SEA). This review provides an evaluation of the currently available literature and identifies research priorities in applying low-cost sensors (LCS) in PM2.5 environmental and health research in SEA. The research priority is an outcome of a series of participatory workshops under the umbrella of the International Global Atmospheric Chemistry Project–Monsoon Asia and Oceania Networking Group (IGAC–MANGO). A literature review and research prioritization are conducted with a transdisciplinary perspective of providing useful scientific evidence in assisting authorities in formulating targeted strategies to reduce severe PM2.5 pollution and health risks in this region. The PM2.5 research gaps that could be filled by LCS application are identified in five categories: source evaluation, especially for the distinctive sources in the SEA countries; hot spot investigation; peak exposure assessment; exposure–health evaluation on acute health impacts; and short-term standards. The affordability of LCS, methodology transferability, international collaboration, and stakeholder engagement are keys to success in such transdisciplinary PM2.5 research. Unique contributions to the international science community and challenges with LCS application in PM2.5 research in SEA are also discussed.
Collapse
Affiliation(s)
- Shih-Chun Candice Lung
- Research Center for Environmental Changes, Academia Sinica, Taipei 115, Taiwan; (S.-Y.L.); (W.-C.V.W.); (M.-C.M.T.)
- Department of Atmospheric Sciences, National Taiwan University, Taipei 106, Taiwan
- Correspondence: ; Tel.: +886-2-27875908
| | - To Thi Hien
- Faculty of Environment, University of Science, Ho Chi Minh City 700000, Vietnam; (T.T.H.); (T.C.-T.)
- Vietnam National University, Ho Chi Minh City 700000, Vietnam
| | - Maria Obiminda L. Cambaliza
- Department of Physics, Ateneo de Manila University, Quezon City 1108, Philippines;
- Air Quality Dynamics Laboratory, Manila Observatory, Quezon City 1108, Philippines;
| | | | - Nguyen Thi Kim Oanh
- Environmental Engineering and Management, SERD, Asian Institute of Technology, Pathumthani 12120, Thailand;
| | - Mohd Talib Latif
- Department of Earth Sciences and Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia;
| | - Puji Lestari
- Faculty of Civil and Environmental Engineering, Bandung Institute of Technology, Bandung 40132, Indonesia;
| | - Abdus Salam
- Department of Chemistry, Faculty of Science, University of Dhaka, Dhaka 1000, Bangladesh; (A.S.); (S.R.)
| | - Shih-Yu Lee
- Research Center for Environmental Changes, Academia Sinica, Taipei 115, Taiwan; (S.-Y.L.); (W.-C.V.W.); (M.-C.M.T.)
| | - Wen-Cheng Vincent Wang
- Research Center for Environmental Changes, Academia Sinica, Taipei 115, Taiwan; (S.-Y.L.); (W.-C.V.W.); (M.-C.M.T.)
| | - Ming-Chien Mark Tsou
- Research Center for Environmental Changes, Academia Sinica, Taipei 115, Taiwan; (S.-Y.L.); (W.-C.V.W.); (M.-C.M.T.)
| | - Tran Cong-Thanh
- Faculty of Environment, University of Science, Ho Chi Minh City 700000, Vietnam; (T.T.H.); (T.C.-T.)
- College of Public Health, National Taiwan University, Taipei 100, Taiwan
| | | | - Kraichat Tantrakarnapa
- Department of Social and Environmental Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand;
| | - Murnira Othman
- Institute for Environment and Development (Lestari), Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia;
| | - Shatabdi Roy
- Department of Chemistry, Faculty of Science, University of Dhaka, Dhaka 1000, Bangladesh; (A.S.); (S.R.)
| | - Tran Ngoc Dang
- Department of Environmental Health, Faculty of Public Health, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh 700000, Vietnam;
| | - Dwi Agustian
- Department of Public Health, Faculty of Medicine, Universitas Padjadjaran, Bandung 40171, Indonesia;
| |
Collapse
|
22
|
Internet of Things (IoT) Technologies for Managing Indoor Radon Risk Exposure: Applications, Opportunities, and Future Challenges. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112211064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Radon gas is a harmful pollutant with a well-documented adverse influence on public health. In poorly ventilated environments, that are often prone to significant radon levels, studies indicate a known relationship between human radon exposure and lung cancer. Recent technology advances, notably on the Internet of Things (IoT) ecosystem, allow the integration of sensors, computing, and communication capabilities into low-cost and small-scale devices that can be used for implementing specific cyber-physical systems (CPS) for online and real-time radon management. These technologies are crucial for improving the overall building indoor air quality (IAQ), contributing toward the so-called cognitive buildings, where human-based control is tending to decline, and building management systems (BMS) are focused on balancing critical factors, such as energy efficiency, human radon exposure management, and user experience, to achieve a more transparent and harmonious integration between technology and the built environment. This work surveys recent IoT technologies for indoor radon exposure management (monitoring, assessment and mitigation), and discusses its main challenges and opportunities, by focusing on methods, techniques, and technologies to answer the following questions: (i) What technologies have been recently in use for radon exposure management; (ii) how they operate; (iii) what type of radon detection mechanisms do they use; and (iv) what type of system architectures, components, and communication technologies have been used to assist the referred technologies. This contribution is relevant to pave the way for designing more intelligent and sustainable systems that rely on IoT and Information and Communications Technology (ICT), to achieve an optimal balance between these two critical factors: human radon exposure management and building energy efficiency.
Collapse
|
23
|
Truong TV, Nayyar A, Masud M. A novel air quality monitoring and improvement system based on wireless sensor and actuator networks using LoRa communication. PeerJ Comput Sci 2021; 7:e711. [PMID: 34616890 PMCID: PMC8459792 DOI: 10.7717/peerj-cs.711] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 08/21/2021] [Indexed: 06/13/2023]
Abstract
In this paper, we study the air quality monitoring and improvement system based on wireless sensor and actuator network using LoRa communication. The proposed system is divided into two parts, indoor cluster and outdoor cluster, managed by a Dragino LoRa gateway. Each indoor sensor node can receive information about the temperature, humidity, air quality, dust concentration in the air and transmit them to the gateway. The outdoor sensor nodes have the same functionality, add the ability to use solar power, and are waterproof. The full-duplex relay LoRa modules which are embedded FreeRTOS are arranged to forward information from the nodes they manage to the gateway via uplink LoRa. The gateway collects and processes all of the system information and makes decisions to control the actuator to improve the air quality through the downlink LoRa. We build data management and analysis online software based on The Things Network and TagoIO platform. The system can operate with a coverage of 8.5 km, where optimal distances are established between sensor nodes and relay nodes and between relay nodes and gateways at 4.5 km and 4 km, respectively. Experimental results observed that the packet loss rate in real-time is less than 0.1% prove the effectiveness of the proposed system.
Collapse
Affiliation(s)
- Truong Van Truong
- Faculty of Electrical-Electronic Engineering and Institute of Research and Development, Duy Tan University, Da Nang, Viet Nam
| | - Anand Nayyar
- Graduate School; Faculty of Information Technology, Duy Tan University, Da Nang, Viet Nam
| | - Mehedi Masud
- Department of Computer Science, College of Computers and Information Technology, Taif University, Taif, Saudi Arabia
| |
Collapse
|
24
|
Application of Low-Cost Sensors for Building Monitoring: A Systematic Literature Review. BUILDINGS 2021. [DOI: 10.3390/buildings11080336] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
In recent years, many scholars have dedicated their research to the development of low-cost sensors for monitoring of various parameters. Despite their high number of applications, the state of the art related to low-cost sensors in building monitoring has not been addressed. To fill this gap, this article presents a systematic review, following well-established methodology, to analyze the state of the art in two aspects of structural and indoor parameters of buildings, in the SCOPUS database. This analysis allows to illustrate the potential uses of low-cost sensors in the building sector and addresses the scholars the preferred communication protocols and the most common microcontrollers for installation of low-cost monitoring systems. In addition, special attention is paid to describe different areas of the two mentioned fields of building monitoring and the most crucial parameters to be monitored in buildings. Finally, the deficiencies in line with limited number of studies carried out in various fields of building monitoring are overviewed and a series of parameters that ought to be studied in the future are proposed.
Collapse
|
25
|
Lopes SI, Nunes LJR, Curado A. Designing an Indoor Radon Risk Exposure Indicator (IRREI): An Evaluation Tool for Risk Management and Communication in the IoT Age. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:7907. [PMID: 34360202 PMCID: PMC8345734 DOI: 10.3390/ijerph18157907] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/20/2021] [Accepted: 07/22/2021] [Indexed: 11/20/2022]
Abstract
The explosive data growth in the current information age requires consistent new methodologies harmonized with the new IoT era for data analysis in a space-time context. Moreover, intuitive data visualization is a central feature in exploring, interpreting, and extracting specific insights for subsequent numerical data representation. This integrated process is normally based on the definition of relevant metrics and specific performance indicators, both computed upon continuous real-time data, considering the specificities of a particular application case for data validation. This article presents an IoT-oriented evaluation tool for Radon Risk Management (RRM), based on the design of a simple and intuitive Indoor Radon Risk Exposure Indicator (IRREI), specifically tailored to be used as a decision-making aid tool for building owners, building designers, and buildings managers, or simply as an alert flag for the problem awareness of ordinary citizens. The proposed methodology was designed for graphic representation aligned with the requirements of the current IoT age, i.e., the methodology is robust enough for continuous data collection with specific Spatio-temporal attributes and, therefore, a set of adequate Radon risk-related metrics can be extracted and proposed. Metrics are summarized considering the application case, taken as a case study for data validation, by including relevant variables to frame the study, such as the regulatory International Commission on Radiological Protection (ICRP) dosimetric limits, building occupancy (spatial dimension), and occupants' exposure periods (temporal dimension). This work has the following main contributions: (1) providing a historical perspective regarding RRM indicator evolution along time; (2) outlining both the formulation and the validation of the proposed IRREI indicator; (3) implementing an IoT-oriented methodology for an RRM indicator; and (4) a discussion on Radon risk public perception, undertaken based on the results obtained after assessment of the IRREI indicator by applying a screening questionnaire with a total of 873 valid answers.
Collapse
Affiliation(s)
- Sérgio Ivan Lopes
- ADiT-Lab, Instituto Politécnico de Viana do Castelo, Rua da Escola Industrial e Comercial de Nun’Alvares, 4900-347 Viana do Castelo, Portugal
- IT—Instituto de Telecomunicações, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
| | - Leonel J. R. Nunes
- PROMETHEUS, Unidade de Investigação em Materiais, Energia e Ambiente para a Sustentabilidade, Escola Superior Agrária, Instituto Politécnico de Viana do Castelo, Rua da Escola Industrial e Comercial de Nun’Alvares, 4900-347 Viana do Castelo, Portugal;
| | - António Curado
- PROMETHEUS, Unidade de Investigação em Materiais, Energia e Ambiente para a Sustentabilidade, Escola Superior de Tecnologia e Gestão, Instituto Politécnico de Viana do Castelo, Rua da Escola Industrial e Comercial de Nun’Alvares, 4900-347 Viana do Castelo, Portugal;
| |
Collapse
|
26
|
Cyber-Physical Systems Improving Building Energy Management: Digital Twin and Artificial Intelligence. ENERGIES 2021. [DOI: 10.3390/en14082338] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The research explores the potential of digital-twin-based methods and approaches aimed at achieving an intelligent optimization and automation system for energy management of a residential district through the use of three-dimensional data model integrated with Internet of Things, artificial intelligence and machine learning. The case study is focused on Rinascimento III in Rome, an area consisting of 16 eight-floor buildings with 216 apartment units powered by 70% of self-renewable energy. The combined use of integrated dynamic analysis algorithms has allowed the evaluation of different scenarios of energy efficiency intervention aimed at achieving a virtuous energy management of the complex, keeping the actual internal comfort and climate conditions. Meanwhile, the objective is also to plan and deploy a cost-effective IT (information technology) infrastructure able to provide reliable data using edge-computing paradigm. Therefore, the developed methodology led to the evaluation of the effectiveness and efficiency of integrative systems for renewable energy production from solar energy necessary to raise the threshold of self-produced energy, meeting the nZEB (near zero energy buildings) requirements.
Collapse
|
27
|
Koondhar MA, Shahbaz M, Memon KA, Ozturk I, Kong R. A visualization review analysis of the last two decades for environmental Kuznets curve "EKC" based on co-citation analysis theory and pathfinder network scaling algorithms. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:16690-16706. [PMID: 33389469 DOI: 10.1007/s11356-020-12199-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 12/22/2020] [Indexed: 06/12/2023]
Abstract
Environmental Kuznets curve (EKC) is a statistical tool to examine the cointegration and causality nexus between economic growth and carbon emissions. The EKC is widely used in energy and environmental economics studies. Although a large number of researchers have analyzed the EKC by applying different statistical models, some review work has been summarized to draw a pictorial view of extending studies in this research field. However, still, the macroscopic overview needs to be considered. Therefore, this study aims to contribute to the literature for finding a new pathway for further research employing, and to facilitate this research, scientometric analysis is carried out by feature in CiteSpace. The dataset was screened and found 2384 records out of 59,225 Web of Science (WoS) references, and the records for the timespan 1999-2019 was used to visualize the knowledge map and outcome of the scientific enterprise. The visualization results reveal the most influencing studies, institutions, authors, countries, keywords, and category cloud, in the research field of EKC. This article reveals that the research on EKC in alignment with green and sustainable technology science requires more attention. Further, this article would help authors and publishers make their decisions for the research of EKC and planning for future perspectives to contribute to academic development and applied methodology.
Collapse
Affiliation(s)
- Mansoor Ahmed Koondhar
- College of Economics and Management, Northwest A&F University, Yangling, Xianyang, 712100, China
| | - Muhammad Shahbaz
- Economics Center for energy and Environmental Policy of Research, Beijing Institute Technology, Beijing, 100081, China
| | - Kamran Ali Memon
- Department of Electronics Engineering, Quaid-e-Awam University of Engineering, Science & Technology, Nawabshah, Pakistan
| | - Ilhan Ozturk
- Faculty of Economics and Administrative Sciences, Cag University, Mersin, Turkey
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung, Taiwan
- Department of Finance, Asia University, 500, Lioufeng Rd., Wufeng, Taichung, 41354, Taiwan
| | - Rong Kong
- College of Economics and Management, Northwest A&F University, Yangling, Xianyang, 712100, China.
| |
Collapse
|
28
|
Energy Modelling and Analytics in the Built Environment—A Review of Their Role for Energy Transitions in the Construction Sector. ENERGIES 2021. [DOI: 10.3390/en14030679] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Decarbonisation and efficiency goals set as a response to global warming issue require appropriate decision-making strategies to promote an effective and timely change in energy systems. Conceptualization of change is a relevant part of energy transitions research today, which aims at enabling radical shifts compatible with societal functions and market mechanisms. In this framework, construction sector can play a relevant role because of its energy and environmental impact. There is, however, the need to move from general instances to specific actions. Open data and open science, digitalization and building data interoperability, together with innovative business models could represent enabling factors to accelerate the process of change. For this reason, built environment research has to address the co-evolution of technologies and human behaviour and the analytical methods used for this purpose should be empirically grounded, transparent, scalable and consistent across different temporal/spatial scales of analysis. These features could potentially enable the emergence of “ecosystems” of applications that, in turn, could translate into projects, products and services for energy transitions in the built environment, proposing innovative business models that can stimulate market competitiveness. For these reasons, in this paper we organize our analysis according to three levels, from general concepts to specific issues. In the first level, we consider the role of building energy modelling at multiple scales. In the second level, we focus on harmonization of methods for energy performance analysis. Finally, in the third level, we consider emerging concepts such as energy flexibility and occupant-centric energy modelling, considering their relation to monitoring systems and automation. The goal of this research is to evaluate the current state of the art and identify key concepts that can encourage further research, addressing both human and technological factors that influence energy performance of buildings.
Collapse
|
29
|
Saini J, Dutta M, Marques G. Sensors for indoor air quality monitoring and assessment through Internet of Things: a systematic review. ENVIRONMENTAL MONITORING AND ASSESSMENT 2021; 193:66. [PMID: 33452599 DOI: 10.1007/s10661-020-08781-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 11/30/2020] [Indexed: 06/12/2023]
Abstract
The growing populations around the world are closely associated with rising levels of air pollution. The impact is not restricted to outdoor areas. Moreover, the health of building occupants is also deteriorating due to poor indoor air quality. As per the World Health Organization, indoor air pollution is a leading cause of 1.6 million premature deaths annually. Therefore, numerous companies have started the development of low-cost sensors to monitor indoor air pollution with the Internet of Things-based applications. However, due to the close association of air pollution levels to the mortality and morbidity rates, communities face several limitations while selecting sensors to address this public health challenge. The main contribution of this systematic review is to present a qualitative and quantitative evaluation of low-cost sensors while providing deep insights into the selection criteria for adequate monitoring. The authors in this paper discussed studies published after the year 2015, and it includes an analysis of papers published in the English language only. Moreover, this study highlights crucial research questions, states answers, and provides recommendations for future research studies. The outcomes of this paper will be useful for students, researchers, and industry members concerning the upcoming research and manufacturing activities. The results show that 28 studies (70%) include indoor thermal comfort assessment, 26 (65%) and 12 (30%) studies include CO2 and CO sensors, respectively. In total, 32 (45.7%) out of 71 sensors (whose prices are available) discussed in this study are available in a price below the US $20 over online marketplaces. Furthermore, the authors conclude that 77.5% of the analyzed literature does not include calibration details, and the accuracy specification is missing for 39.4% sensors.
Collapse
Affiliation(s)
- Jagriti Saini
- National Institute of Technical Teacher's Training and Research, Chandigarh, 160019, India.
| | - Maitreyee Dutta
- National Institute of Technical Teacher's Training and Research, Chandigarh, 160019, India
| | - Goncalo Marques
- Polytechnic of Coimbra, ESTGOH, 3400-124, Oliveira do Hospital, Portugal
| |
Collapse
|
30
|
Lee H. A Basic Study on the Performance Evaluation of a Movable Light Shelf with a Rolling Reflector That Can Change Reflectivity to Improve the Visual Environment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17228338. [PMID: 33187274 PMCID: PMC7696370 DOI: 10.3390/ijerph17228338] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 11/07/2020] [Accepted: 11/09/2020] [Indexed: 12/11/2022]
Abstract
In recent years, the need for comfortable visual environments in indoor spaces has increased energy use in buildings. There have been diverse studies on using a light shelf to solve this problem. It is an effective system that allows external natural light deep into indoor spaces through reflection. However, prior studies have used light shelves with a fixed reflectivity, and there are few studies on improving the visual environment through light shelf control. Therefore, this study proposes a movable light shelf with a rolling reflector that can change the reflectivity. To achieve these objectives, we conducted a performance evaluation of the system’s ability to save energy and improve the visual environment. This study built a real scale testbed and conducted a performance evaluation by deriving values for lighting energy consumption, uniformity, and luminance contrast depending on the light shelf variables. We conclude that (1) the light shelf system achieved an energy savings of 13.6% and 5.7%, respectively, compared to a fixed type light shelf, whose reflectivity cannot be changed, and a traditional movable light shelf; (2) in terms of improving the visual environment, results suggest that the visual environment could be improved using a light shelf by deriving light shelf variables that disturb indoor uniformity; and (3) the results verified glare generation conditions by deriving luminance contrast caused by the variables of light shelf angle and its reflectivity.
Collapse
Affiliation(s)
- Heangwoo Lee
- College of Design, Sangmyung University, Cheonan-si 03012, Chungcheongnam-do, Korea
| |
Collapse
|