1
|
Moradinezhad M, Abbasi Montazeri E, Hashemi Ashtiani A, Pourlotfi R, Rakhshan V. Biofilm formation of Streptococcus mutans, Streptococcus sanguinis, Staphylococcus epidermidis, Staphylococcus aureus, Lactobacillus casei, and Candida Albicans on 5 thermoform and 3D printed orthodontic clear aligner and retainer materials at 3 time points: an in vitro study. BMC Oral Health 2024; 24:1107. [PMID: 39294648 PMCID: PMC11412017 DOI: 10.1186/s12903-024-04893-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 09/10/2024] [Indexed: 09/21/2024] Open
Abstract
INTRODUCTION Orthodontic clear aligners and retainers have numerous advantages that is making them ever increasingly popular. However, they might, similar to any other oral appliance, contribute to biofilm formation and finally dental caries or white spot lesions or gingival inflammations. The literature on biofilm formation on orthodontic clear appliances is very scarce and limited to a few microorganisms and materials. Therefore, this experimental study evaluated the biofilm formation on 5 thermoformed and 3D printed CAD/CAM orthodontic retainers in 3 intervals. METHODS In this in vitro study, 345 specimens (270 test discs and 45 negative controls) were created from fabricated retainers. Retainers included a 3D printed CAD/CAM material (Detax) and four thermoformed retainers [Erkodent (polyethylene terephthalate glycol [PETG]); EasyVac (polyethylene); DB (polyester based on terephthalic acid); and Clear Tech]. They were all 1 mm thick, and all completely fabricated, i.e., heated or printed. The discs were placed in 96-well plates. Microorganisms were cultured on 270 discs for 24 h (90 discs), 72 h (90 other discs), and 5 days or 120 h (90 other discs). Biofilm formation of the strains and negative controls was measured using the microtiter plate assay by ELISA reading. The microbes' ability to produce biofilm was categorized based on the comparison of average optical density (OD) of tests versus a cut-off point OD (ODc) calculated as the average of the OD of corresponding negative controls plus 3× its standard deviation: non-biofilm former [OD ≤ ODc], weak biofilm former [ODc < OD ≤ (2 × ODc)], moderate biofilm former [(2 × ODc) < OD ≤ (4 × ODc)], and strong biofilm former [(4 × ODc) < OD]. These were also converted to ranked scores between zero (no biofilm) and 3. The difference between ODs with control ODs were calculated. These were analyzed using 3-way ANOVA, 2-way ANOVA, and Tukey tests (α = 0.05, α = 0.008). RESULTS The 3-way ANOVA showed that the overall difference among the ΔODs of 5 retainers (all microorganisms and all intervals combined, n = 270) was not significant (F = 1.860, P = 0.119). Nevertheless, the difference among 3 intervals (F = 31.607, P = 0.0000) and the difference among the 6 microorganisms (F = 24.044, P = 0.0000) were significant. According to the Tukey test, the differences between the 1st interval with either of the other two intervals was significant (both P values = 0.000). There were significant differences between Candida albicans with all other organisms (all 5 P values = 0.0000). All other pairwise comparisons were insignificant (all 10 P values ≥ 0.1). After taking the averages of the 3 intervals, the order of the biofilm generation for different materials were as follows: Detax (average score: 1.56), Easyvac (1.67), Erkodent (1.78), Clear Tech (1.83), BD (2.28). CONCLUSIONS As far as these 6 microorganisms are of concern, there might not be a significant overall difference among the clear retainer materials tested in this study. A significant overall increase was observed between the first and third days, which later did not significantly increase more until day 5. The Candida albicans biofilm was more intense than the tested 5 bacteria, which themselves showed rather similar growth patterns to each other.
Collapse
Affiliation(s)
- Mehrnaz Moradinezhad
- Department of Orthodontics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Effat Abbasi Montazeri
- Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Alireza Hashemi Ashtiani
- Department of Prosthodontics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Reza Pourlotfi
- School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| | - Vahid Rakhshan
- Department of Dental Anatomy, Azad University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Fiorillo G, Campobasso A, Croce S, Hussain U, Battista G, Lo Muzio E, Mandelli G, Ambrosi A, Gastaldi G. Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations. Orthod Craniofac Res 2024. [PMID: 39158036 DOI: 10.1111/ocr.12846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 07/02/2024] [Accepted: 08/07/2024] [Indexed: 08/20/2024]
Abstract
OBJECTIVE To evaluate the accuracy of dental rotational movements using clear aligners with different attachment configurations. MATERIALS AND METHODS This retrospective study analysed 212 teeth from 89 patients undergoing Invisalign treatment. Digital models were analysed after the virtual treatment plan (ST1) and after the first treatment phase (ET1) to evaluate the effective clinical rotational movement. The rotational movements of incisors, canines, and bicuspids were measured using data from the Clincheck Movements Table. ST1 and ET1 were compared to determine the actual rotational movement achieved (ST1-ET1). The presence or absence of attachments (rectangular or optimized) on teeth was analysed. The accuracy of rotational movements among attachment types was compared using the Kruskal-Wallis test. Multiple linear regressions were conducted with accuracy as the dependent variable and tooth type, gender, and age as predictors. RESULTS Optimized attachments had the highest median accuracy (70%), followed by rectangular (65%), and without attachment (63%), with no significant differences (p = .5). There were no significant differences across age groups, genders, or tooth types. Baseline accuracy was 68.62% (95% CI: 56.03-81.20, p < .001). Age was a significant predictor (estimate = -0.30, 95% CI: -0.58 - -0.03, p = .032), indicating decreased accuracy with increasing age. The model's R2 was 0.046, with an adjusted R2 of 0.003, indicating minimal variance explained. CONCLUSION The addition of attachment configurations to clear aligners improves rotational accuracy, but not significantly. Further advancements in these configurations are needed to enhance the performance of the aligners.
Collapse
Affiliation(s)
- Gianluigi Fiorillo
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy
| | - Alessandra Campobasso
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Silvia Croce
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy
| | - Umar Hussain
- Department of Orthodontics, Saidu College of Dentistry, Swat, Pakistan
| | - Giovanni Battista
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Eleonora Lo Muzio
- Department of Translational Medicine and for Romagna, University of Ferrara, Ferrara, Italy
| | - Gualtiero Mandelli
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy
| | - Alessandro Ambrosi
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy
| | - Giorgio Gastaldi
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy
| |
Collapse
|
3
|
Olteanu ND, Taraboanta I, Panaite T, Balcos C, Rosu SN, Vieriu RM, Dinu S, Zetu IN. Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4009. [PMID: 39203186 PMCID: PMC11355976 DOI: 10.3390/ma17164009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 08/08/2024] [Accepted: 08/09/2024] [Indexed: 09/03/2024]
Abstract
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA® Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system-TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A-artificial saliva, B-cola, C-coffee, D-red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher ΔE values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters ΔL*, Δa*, Δb* and ΔE of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA® Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (ΔL, Δa, Δb and ΔE) of both tested aligner materials.
Collapse
Affiliation(s)
- Nicolae Daniel Olteanu
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Ionut Taraboanta
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Tinela Panaite
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Carina Balcos
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Sorana Nicoleta Rosu
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Raluca Maria Vieriu
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| | - Stefania Dinu
- Department of Pedodontics, Faculty of Dental Medicine, “Victor Babes”, University of Medicine and Pharmacy Timisoara, No. 9, Revolutiei Bv., 300041 Timisoara, Romania;
| | - Irina Nicoleta Zetu
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine “Grigore T. Popa”, University of Medicine and Pharmacy from Iasi, Str. Universitatii 16, 700115 Iasi, Romania; (N.D.O.); (I.T.); (T.P.); (C.B.); (R.M.V.); (I.N.Z.)
| |
Collapse
|
4
|
Iliadi A, Zervou SK, Koletsi D, Schätzle M, Hiskia A, Eliades T, Eliades G. Surface alterations and compound release from aligner attachments in vitro. Eur J Orthod 2024; 46:cjae026. [PMID: 38884540 PMCID: PMC11181360 DOI: 10.1093/ejo/cjae026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2024]
Abstract
AIM The aim of the present study was to assess the alterations in morphology, roughness, and composition of the surfaces of a conventional and a flowable composite attachment engaged with aligners, and to evaluate the release of resin monomers and their derivatives in an aqueous environment. METHODS Zirconia tooth-arch frames (n = 20) and corresponding thermoformed PET-G aligners with bonded attachments comprising two composite materials (universal-C and flowable-F) were fabricated. The morphological features (stereomicroscopy), roughness (optical profilometry), and surface composition (ATR-FTIR) of the attachments were examined before and after immersion in water. To simulate intraoral use, the aligners were removed and re-seated to the frames four times per day for a 7-day immersion period. After testing, the eluents were analyzed by LC-MS/MS targeting the compounds Bis-GMA, UDMA, 2-HEMA, TEGDMA and BPA and by LC-HRMS for suspect screening of the leached dental material compounds and their degradation products. RESULTS After testing, abrasion-induced defects were found on attachment surfaces such as scratches, marginal cracks, loss of surface texturing, and fractures. The morphological changes and debonding rate were greater in F. Comparisons (before-after testing) revealed a significantly lower Sc roughness parameter in F. The surface composition of the aligners after testing showed minor changes from the control, with insignificant differences in the degree of C = C conversion, except for few cases with strong evidence of hydrolytic degradation. Targeted analysis results revealed a significant difference in the compounds released between Days 1 and 7 in both materials. Insignificant differences were found when C was compared with F in both timeframes. Several degradation products were detected on Day 7, with a strong reduction in the concentration of the targeted compounds. CONCLUSIONS The use of aligners affects the surface characteristics and degradation rate of composite attachments in an aqueous environment, releasing monomers, and monomer hydrolysates within 1-week simulated use.
Collapse
Affiliation(s)
- Anna Iliadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
- Faculty of Medicine and Health Technology, University of Tampere, Finland
| | - Sevasti-Kiriaki Zervou
- Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechnology, National Centre for Scientific Research ‘Demokritos’, Athens, Greece
| | - Despina Koletsi
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
- Meta-Research Innovation Center at Stanford (METRICS), Stanford University, CA, USA
| | - Marc Schätzle
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
| | - Anastasia Hiskia
- Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechnology, National Centre for Scientific Research ‘Demokritos’, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| |
Collapse
|
5
|
Eliades T, Eliades G. Intraoral ageing of aligners and attachments: Adverse effects on clinical efficiency and release of biologically-active compounds. Korean J Orthod 2024; 54:199-209. [PMID: 38926752 PMCID: PMC11270147 DOI: 10.4041/kjod24.085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 05/14/2024] [Indexed: 06/28/2024] Open
Abstract
The clinical application of aligners is accompanied by the ageing of the polymer appliances and the attachments used, which may result in inefficiency in reaching the predicted range of tooth movement, and release of compounds and microplastics in the oral cavity as a result of the friction, wear and attrition of the aligner and composite attachment. The purpose of this review is to present the mechanism and effects of in vivo ageing; describe the hydrolytic degradation of aligners and enzymatic degradation of composite attachments; examine the ageing pattern of aligners in vivo, under actual clinical scenarios; and identify a link to the discrepancy between predicted and actual clinical outcome. Lastly, strategies to deal with three potentially critical issues associated with the use of aligners, namely the necessity of weekly renewal, the dissimilar mechanical properties of aligner and attachment resulting in wear and plastic deformation of the aligner, and the development of integuments and biofilms with microbial colonization of the appliance, are discussed.
Collapse
Affiliation(s)
- Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
6
|
Porojan L, Toma FR, Gherban MI, Vasiliu RD, Matichescu A. Surface Topography of Thermoplastic Appliance Materials Related to Sorption and Solubility in Artificial Saliva. Biomimetics (Basel) 2024; 9:379. [PMID: 39056820 PMCID: PMC11274910 DOI: 10.3390/biomimetics9070379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 06/07/2024] [Accepted: 06/15/2024] [Indexed: 07/28/2024] Open
Abstract
(1) Background: PETG (polyethylene terephthalate glycol) is a transparent, inexpensive, and versatile thermoplastic biomaterial, and it is increasingly being used for a variety of medical applications in dentistry, orthopedics, tissue engineering, and surgery. It is known to have remarkable properties such as tensile strength, high ductility, and resistance to chemical insults and heat, but it can be affected by various environmental conditions. The aim of the present study was to evaluate the topographical characteristics of four thermoplastic dental appliance materials in relation to water sorption in simulated oral environments (artificial saliva samples with different pH values). (2) Methods: The following four types of PETG clear thermoplastic materials were selected for the present study: Leone (L), Crystal (C), Erkodur (E), and Duran (D). In relation to the desiccation and water-uptake stages, their water sorption (Wsp) and solubility (Wsl) were calculated, and the surface topographies were analyzed on two length scales. The surface roughness was determined using a contact profilometer, and nanoroughness measurements were generated by three-dimensional profiles using an atomic force microscope (AFM). Statistical analyses (one-way ANOVA and unpaired and paired Student t-tests) were performed. (3) Results: After saliva immersion, the weights of all samples increased, and the highest sorption was recorded in a basic environment. Among the materials, the water uptake for the L samples was the highest, and for E, it was the lowest. In relation to water solubility, significant values were registered for both the L and C samples' materials. After immersion and desiccation, a decreasing trend in microroughness was observed. The AFM high-resolution images reflected more irregular surfaces related to saliva immersion. (4) Conclusions: The sorption rates recorded in water-based artificial saliva were higher for basic pH levels, with significant differences between the samples. There were also significant differences related to the behaviors of the materials included in the study. In relation to roughness, on a microscale, the surfaces tended to be smoother after the saliva immersions, and on a nanoscale, they became more irregular.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Gherban
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania;
| |
Collapse
|
7
|
Roulias P, Vasoglou G, Angelopoulos G, Pandis N, Sifakakis I. Effect of aligners on patients' oral health-related quality of life and anxiety: a prospective pilot study. BMC Psychol 2024; 12:346. [PMID: 38867321 PMCID: PMC11170843 DOI: 10.1186/s40359-024-01834-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 05/30/2024] [Indexed: 06/14/2024] Open
Abstract
BACKGROUND This prospective study explored the impact of aligners on the oral health-related quality of life and anxiety of patients during the first month of orthodontic treatment and the first month of the retention phase. METHODS A total of 23 male and female patients (median age 25 y) treated with clear aligners were included. The OHRQoL questionnaire was used at certain time points during treatment (T1: placement of the first aligner; T2: after one day of use; T3: after seven days; T4: after one month; and T5: after one month in the retention phase). The State-Trait Anxiety Inventory (STAI) was also self-administered to assess state and trait anxiety (Y1 and Y2 subscales, respectively) at the T1, T4 and T5 time points. A population average generalized estimating equations logistic regression model was fit to assess the effect of time on the responses, and the Wald test was used to examine the overall effect of time. RESULTS Overall time was a significant predictor for most of the questions. However, time was marginally significant for the OHRQoL questions evaluating oral symptoms such as bad taste/smell, sores, and food accumulation. Tooth discolouration did not differ between time points. The general activity disturbance was significantly lower in the retention phase. Higher depression and anxiety scores were reported at the initial appointment and decreased thereafter. CONCLUSIONS CAT has a negative impact on quality of life and psychological status during the initial days of treatment. These impairments ameliorate at later treatment stages.
Collapse
Affiliation(s)
- Panagiotis Roulias
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Georgios Vasoglou
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Gerassimos Angelopoulos
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Nikolaos Pandis
- Department of Orthodontics and Dentofacial Orthopedics, Dental School/Medical Faculty, University of Bern, Bern, Switzerland
| | - Iosif Sifakakis
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.
| |
Collapse
|
8
|
Stocker L, Zervou SK, Papageorgiou SN, Karakousoglou S, Triantis T, Hiskia A, Eliades G, Eliades T. Salivary levels of eluents during Invisalign™ treatment with attachments: an in vivo investigation. Prog Orthod 2024; 25:22. [PMID: 38825612 PMCID: PMC11144685 DOI: 10.1186/s40510-024-00522-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 05/10/2024] [Indexed: 06/04/2024] Open
Abstract
BACKGROUND The aim of the present study was to investigate qualitatively and quantitatively the elution of substances from polyester-urethane (Invisalign™) aligners and resin composite attachments (Tetric EvoFlow) in vivo. METHODS Patients (n = 11) treated with the aligners and attachments (16 per patient, without other composite restorations) for an average of 20 months, who were planned for attachment removed were enrolled in the study. Patients were instructed to rinse with 50 mL of distilled water upon entry and the rinsing solution was collected (before removal). Then, the attachments were removed with low-speed tungsten carbide burs for adhesive residue removal, a thorough water rinsing was performed immediately after the grinding process to discard grinding particle residues, and subsequently, after a second water-rinsing the solution was collected for analysis (after removal). The rinsing solutions were analyzed for targeted (LC-MS/MS: Bis-GMA, DCDMA, UDMA, BPA) and untargeted (LC-HRMS: screening of leached species and their degradation products) compounds. RESULTS Targeted analysis revealed a significant reduction in BPA after attachment removal (4 times lower). Bis-GMA, DCDMA, UDMA were below the detection limit before removal but were all detectable after removal with Bis-GMA and UDMA at quantifiable levels. Untargeted analysis reviled the presence of mono-methacrylate transformation products of Bis-GMA (Bis-GMA-M1) and UDMA (UDMA-M1), UDMA without methacrylate moieties (UDMA-M2), and 4-(dimethylamino) benzoic acid (DMAB), the degradation product of the photo-initiator ethyl-4-(dimethylamino) benzoate (EDMAB), all after attachment removal. Several amino acids and endogenous metabolites were also found both before and after removal. CONCLUSIONS Elevated levels of BPA were traced instantaneously in patients treated with Invisalign™ and flowable resin composite attachments for the testing period. BPA was reduced after attachment removal, but residual monomers and resin degradation products were found after removal. Alternative resin formulations and attachment materials may be utilized to reduce eluents.
Collapse
Affiliation(s)
- Larissa Stocker
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | - Sevasti-Kiriaki Zervou
- Laboratory for Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechology, National Center for Scientific Research "Demokritos", Agia Paraskevi, Greece
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | | | - Theodoros Triantis
- Laboratory for Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechology, National Center for Scientific Research "Demokritos", Agia Paraskevi, Greece
| | - Anastasia Hiskia
- Laboratory for Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechology, National Center for Scientific Research "Demokritos", Agia Paraskevi, Greece
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland.
| |
Collapse
|
9
|
Barile C, Cianci C, Paramsamy Kannan V, Pappalettera G, Pappalettere C, Casavola C, Suriano C, Ciavarella D. Thermoplastic clear dental aligners under cyclic compression loading: A mechanical performance analysis using acoustic emission technique. J Mech Behav Biomed Mater 2024; 152:106451. [PMID: 38310814 DOI: 10.1016/j.jmbbm.2024.106451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/26/2024] [Accepted: 01/30/2024] [Indexed: 02/06/2024]
Abstract
The objective of this work is to analyse the performance of clear aligners made of thermoplastic materials. Within this framework, the damage evolution stages and damage states of the aligners at different cycles of the compressive loading are evaluated using the Acoustic Emission (AE) technique. Three different clear aligner systems were prepared: thermoformed PET-g (polyethylene terephthalate glycol) and PU (polyurethane), and additively manufactured PU. Cyclic compression tests are performed to simulate 22500 swallows. The mechanical results show that the energy absorbed by the thermoformed PET-g aligner remains stable around 4 Nmm throughout the test. Although the PU-based aligners show a higher energy absorption of about 7 Nmm during the initial phase of the cyclic loading, this gradually decreases after 12500 cycles. The time-domain based, and frequency-based parameters of the stress wave acoustic signals generated by the aligners under compression loading are used to identify the damage evolution stages. The machine learning-based AE results reveal the initiation and termination of the different damage states in the aligners and the frequency-based results distinguish the different damage sources. Finally, the microscopy results validated the damage occurrences in the aligners identified by the AE results. The mechanical test results indicate that the thermoformed PET-g has the potential to match the performance and requirements of the dentistry of the popular Invisalign (additively manufactured PU). The AE results have the potential to identify at which cycles the aligners may start losing their functionality.
Collapse
Affiliation(s)
- Claudia Barile
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, Italy
| | - Claudia Cianci
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, Italy
| | | | - Giovanni Pappalettera
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, Italy.
| | - Carmine Pappalettere
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, Italy
| | - Caterina Casavola
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, Italy
| | - Carmela Suriano
- Dipartimento di Medicina Sperimentale e Clinica, Università di Foggia, Foggia, Italy
| | - Domenico Ciavarella
- Dipartimento di Medicina Sperimentale e Clinica, Università di Foggia, Foggia, Italy
| |
Collapse
|
10
|
Srinivasan B, Padmanabhan S, Srinivasan S. Comparative evaluation of physical and mechanical properties of clear aligners - a systematic review. Evid Based Dent 2024; 25:53. [PMID: 38017152 DOI: 10.1038/s41432-023-00937-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 09/25/2023] [Indexed: 11/30/2023]
Abstract
INTRODUCTION The clinical effectiveness of clear aligners depends on the material properties both physical and mechanical. The purpose of this systematic review is to evaluate the physical and mechanical properties of different clear aligner materials and changes in the same during and after intra-oral use. METHODS Search was done in five electronic databases: Pubmed, Embase, Scopus, Web of Science and Ovid individually by two reviewers. In vivo, Ex vivo and In vitro studies that evaluated the physical and mechanical properties of clear aligner materials were selected. The risk of bias assessment was performed using a modified Cochrane risk of bias tool. RESULTS From the 24 articles selected, 19 evaluated a single physical property and 23 articles evaluated a single mechanical property of clear aligner materials. All domains in the risk of bias assessment showed low risk of bias except for 'blinding of outcome' which was unclear in almost all the selected studies. Properties such as hardness, optical properties, stiffness, and yield strength were found to be different for different clear aligner materials and were found to change with thermoforming, with intra-oral aging, and in simulated intraoral conditions. Due to heterogenicity in the parameters used to assess physical or mechanical properties a meta-analysis could not be done. CONCLUSIONS Properties like hardness, color, stiffness, stress relaxation and creep behavior were different for various clear aligner materials and were found to deteriorate with thermoforming and intra-oral aging. Polyurethane-based materials have a higher level of hardness and stiffness but exhibit increased creep and stress relaxation properties. PROSPERO REGISTRATION NUMBER CRD42021269597.
Collapse
Affiliation(s)
- Bhadrinath Srinivasan
- Department of Orthodontics, Sri Ramchandra Institute of Higher Education and Research, PIN- 600116, Chennai, India
| | - Sridevi Padmanabhan
- Department of Orthodontics, Sri Ramchandra Institute of Higher Education and Research, PIN- 600116, Chennai, India.
| | - Sivakumar Srinivasan
- Department of Applied Mechanics, Indian Institute of Technology (Madras), 600036, Chennai, India
| |
Collapse
|
11
|
Cen X, Pan X, Wang R, Huang X, Zhao Z. The complex of tannic acid and cetylpyridinium chloride: An antibacterial and stain-removal cleaner for aligners. Am J Orthod Dentofacial Orthop 2024; 165:173-185. [PMID: 37906245 DOI: 10.1016/j.ajodo.2023.08.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 08/01/2023] [Accepted: 08/01/2023] [Indexed: 11/02/2023]
Abstract
INTRODUCTION Effective aligner hygiene is recognized as an important part of orthodontic treatments and oral hygiene. However, there is no effective cleansing method for removable aligners. METHODS In this study, we incorporated tannic acid (TA) with cetylpyridinium chloride (CPC) to develop the TA-CPC complex. The antibacterial properties of 15.8 mg/mL TA-CPC against Escherichia coli and Staphylococcus aureus were evaluated in vitro, which were compared with 5.1 mg/mL TA, 10.7 mg/mL CPC, a commercial denture cleansing solution (YA; 15 mg/mL), and water. As for the assessment of stain-removal ability, the aligners stained by coffee were soaked in cleansing solutions, and the color changes (ΔE∗) were calculated on the basis of the CIE L∗a∗b∗ color system, and the National Bureau of Standards system was used for the clinical interpretation of the color change. Atomic force microscope examination, tensile property assessment, and wavelength dispersive x-ray fluorescence analysis were performed to investigate the material compatibility of TA-CPC, and Cell Counting Kit-8 assay and live/dead assay were used to test the cytotoxicity of TA-CPC. RESULTS The results showed that TA-CPC had a positive zeta-potential, and cation-π interaction changed the chemical environments of the phenyl group in TA-CPC, resulting in greater inhibition zones of S. aureus and E. coli than other cleaners. The quantification of the biofilm biomass and the fluorescent intensities also reflected that the TA-CPC solution exhibited better antibacterial ability. As for the ability of stain removal, ΔE∗ value of group TA-CPC was 2.84 ± 0.55, whereas those of stained aligners immersed with deionized distilled water, TA, YA, and CPC were 10.26 ± 0.04, 9.54 ± 0.24, 5.93 ± 0.36, and 4.69 ± 0.35, respectively. The visual inspection and National Bureau of Standards ratings also showed that the color of stained aligners cleansed by TA-CPC was much lighter than those of the other groups. Meanwhile, TA-CPC had good compatibility with the aligner material and cells. CONCLUSIONS TA-CPC is a promising strategy to inhibit the formation of biofilms and remove the stains on the aligners safely, which may disinfect the aligners to improve oral health and help keep the transparent appearances of aligners without impacting the morphology and mechanical properties.
Collapse
Affiliation(s)
- Xiao Cen
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xuefeng Pan
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Rong Wang
- Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology, Zhejiang Engineering Research Center for Biomedical Materials, Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China.
| | - Xinqi Huang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| | - Zhihe Zhao
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
12
|
Camenisch L, Polychronis G, Panayi N, Makou O, Papageorgiou SN, Zinelis S, Eliades T. Effect of printing orientation on mechanical properties of 3D-printed orthodontic aligners. J Orofac Orthop 2024:10.1007/s00056-023-00511-0. [PMID: 38277054 DOI: 10.1007/s00056-023-00511-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 12/07/2023] [Indexed: 01/27/2024]
Abstract
PURPOSE The purpose of this study was to assess differences in the fundamental mechanical properties of resin-made three-dimensional (3D) printed orthodontic aligners according to the printing orientation. METHODS Twenty resin 3D-printed dumbbell-shaped specimens and 20 orthodontic aligners were fabricated and postcured in nitrogen. Half of the specimens and aligners were built in horizontal (H), the other half in vertical (V) directions. The dumbbell-shaped specimens were loaded in a tensile testing machine, while parts of the aligners were embedded in acrylic resin, ground, polished, and then underwent instrumented indentation testing (IIT). Mechanical properties that were assessed included the yield strength (YS), breaking strength (BS), plastic strain (ε), Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Data were analyzed statistically with independent t‑tests or Mann-Whitney tests at α = 5%. RESULTS No significant differences were found between specimens or aligners printed either in a horizontal or a vertical direction (P > 0.05 in all instances). Overall, the 3D-printed aligners showed acceptable mechanical propertied in terms of YS (mean 19.2 MPa; standard deviation [SD] 1.7 MPa), BS (mean 19.6 MPa; SD 1.2 MPa), ε (mean 77%; SD 11%), HM (median 89.0 N/mm2; interquartile range [IQR] 84.5-90.0 NN/m2), EIT (median 2670.5 MPa; IQR 2645.0-2726.0 MPa), ηIT (median 27.5%; IQR 25.9-28.1%), and RIT (mean 65.1%; SD 3.5%). CONCLUSION Printing direction seemed to have no effect on the mechanical properties of 3D-printed resin aligners, which are promising for orthodontic use.
Collapse
Affiliation(s)
- Lukas Camenisch
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland
| | - Georgios Polychronis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Nearchos Panayi
- Department of Dentistry, European University Cyprus, Nicosia, Cyprus
| | - Olga Makou
- Department of Dentistry, European University Cyprus, Nicosia, Cyprus
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland.
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland
| |
Collapse
|
13
|
Eslami S, Kopp S, Goteni M, Dahmer I, Sayahpour B. Alterations in the surface roughness and porosity parameters of directly printed and Invisalign aligners after 1 week of intraoral usage: An in vivo prospective investigation. Am J Orthod Dentofacial Orthop 2024; 165:73-79. [PMID: 37665312 DOI: 10.1016/j.ajodo.2023.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 07/01/2023] [Accepted: 07/01/2023] [Indexed: 09/05/2023]
Abstract
INTRODUCTION Direct printing of clear aligners could be the next paradigm shift in modern orthodontics and can potentially overcome the limitation of the indirect production method. This study investigated the effects of 1 week of intraoral usage on the surface roughness parameters of directly printed aligners (DPAs) and commercially produced Invisalign aligners compared with their unused control counterparts using confocal laser scanning microscopy. METHODS The study consisted of 4 groups with 34 samples per group. Unused control aligners were allocated to the control groups (DP-Ctr and INV-Ctr). Sixty-eight patients undergoing clear aligner therapy were allocated to group DP-Clin (patients in therapy using DPAs made from TC-85 DAC resin) and group INV-Clin (patients provided with Invisalign aligners). After 1 week of intraoral usage, the aligners were retrieved from the patients in groups DP-Clin and INV-Clin. Samples were made from the buccal surface of the maxillary right central incisor of each aligner and underwent surface roughness and porosity measuring using confocal laser scanning microscopy. The arithmetic mean deviation of the profile, root mean square deviation, maximum peak height, maximum valley depth, maximum height difference among the highest peak and deepest valley, void volume, and void count were measured. Descriptive analysis and median (quantile) regression models were used for data analysis of this experiment. RESULTS One week of intraoral usage significantly increased the surface roughness and porosity of DPAs. In contrast, a significant reduction in the surface roughness and porosity parameters of Invisalign aligners was recorded after intraoral service. CONCLUSIONS This study suggests an increase in the surface roughness and surface porosity of DPAs following 1 week of intraoral usage, which might lead to an increase in bacterial adhesion and biofilm formation in these aligners.
Collapse
Affiliation(s)
- Sara Eslami
- Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt, Germany.
| | - Stefan Kopp
- Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt, Germany
| | | | - Iulia Dahmer
- Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt, Germany
| | - Babak Sayahpour
- Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt, Germany
| |
Collapse
|
14
|
Cintora-López P, Arrieta-Blanco P, Martin-Vacas A, Paz-Cortés MM, Gil J, Aragoneses JM. In vitro analysis of the influence of the thermocycling and the applied force on orthodontic clear aligners. Front Bioeng Biotechnol 2023; 11:1321495. [PMID: 38173871 PMCID: PMC10761475 DOI: 10.3389/fbioe.2023.1321495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 12/11/2023] [Indexed: 01/05/2024] Open
Abstract
The mechanical properties of polyurethane dental aligners have been studied in an oral environment at 37°C and subjected to thermal cycling between 5°C and 55°C for long periods of time at different mechanical stresses. The aim is to determine the efficacy of the orthodontic aligner at different stress levels, the effect of thermal cycling with therapy time on tooth position correction. Sixty aligners with the same design were studied applying tensions of 0, 3 and 30 N and determining the deformation at different times from 1 to 760 h. Half of these aligners were subjected to stresses submerged in artificial saliva at 37°C and the other half were subjected to thermal cycles between 2°C and 55°C in salivary medium. Deformation was determined using a high-resolution stereo magnifier and ImageJ image analysis software. Water adsorption by the polyurethane was determined at the different test times. The results showed that in the unloaded aligners there is no appreciable deformation, but with thermal cycling there is a light shrinkage of the aligner due to the semi-crystallization process (ordering of polymeric chains) of the polyurethane. When applying loads of 3 and 30 N, creep curves with constant deformation transition zones can be seen. The transition zones decrease as the applied mechanical load increases. In addition, the significant effect of thermal cycling on the reduction of the transition zone of the aligners has been demonstrated. The transition zones are optimal for dental correction as constant stresses are exerted for tooth movement. The effect of thermal cycling shortens the constant deformation zone and reduces tooth alignment time. It was observed that the absorption of water in the aligner is constant after 1 h of immersion and does not exceed 0.4% by weight of absorbed water.
Collapse
Affiliation(s)
| | | | - Andrea Martin-Vacas
- Faculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain
| | | | - Javier Gil
- Faculty of Medicine and Health Sciences, Bionegineering Institute of Technology, International University of Catalunya, Barcelona, Spain
| | | |
Collapse
|
15
|
Koletsi D, Panayi N, Laspos C, Athanasiou AE, Zinelis S, Eliades T. In vivo aging-induced surface roughness alterations of Invisalign ® and 3D-printed aligners. J Orthod 2023; 50:352-360. [PMID: 36573484 PMCID: PMC10693732 DOI: 10.1177/14653125221145948] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 11/23/2022] [Accepted: 11/30/2022] [Indexed: 12/03/2023]
Abstract
OBJECTIVE To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign® appliances, both retrieved as well as in the 'as-received' control status. DESIGN An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS Twelve clinically used Invisalign® appliances and the same number of 3D-printed aligners, without involvement of attachments, were obtained from a respective number of patients. A similar number of 'as-received' aligners, of each material, were used as control (CON) groups. METHOD Four groups of materials were examined: A = Invisalign® CON; B = Invisalign® used; C = 3D-printed CON; and D = 3D-printed used. Optical profilometry was employed to examine the following surface roughness parameters: amplitude parameters Sa, Sq and Sz and functional parameters Sc and Sv. Descriptive statistics and quantile regression modeling were conducted, and the level of statistical significance was set at α = 0.05. RESULTS Intra-oral exposure of 3D-printed aligners was significantly associated with increase in all tested parameters (P < 0.001 at all occasions). Significant differences were detected in the retrieved 3D-printed aligners compared with Invisalign® retrieved, with the exception of Sz. The respective effect sizes (median differences) were as follows: Sa: 169 nm, 95% confidence interval [CI] = 89-248, P < 0.001; Sq: 315 nm, 95% CI = 152-477, P < 0.001; Sc: 233 nm3/nm2, 95% CI = 131-335, P < 0.001; and Sv: 43 nm3/nm2, 95% CI = 17-68, P = 0.002. CONCLUSION Within the limitations of this study, we concluded that surface roughness differences existed between 3D-printed aligners and Invisalign® in the retrieved status, as well as between the control and retrieved 3D-printed groups.
Collapse
Affiliation(s)
- Despina Koletsi
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Nearchos Panayi
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
- Department of Dentistry, School of Medicine, European University Cyprus, Nicosia, Cyprus
- Private practice, Limassol, Cyprus
| | - Christodoulos Laspos
- Department of Dentistry, School of Medicine, European University Cyprus, Nicosia, Cyprus
- Private practice, Limassol, Cyprus
| | | | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
16
|
Šimunović L, Jurela A, Sudarević K, Bačić I, Meštrović S. Differential Stability of One-layer and Three-layer Orthodontic Aligner Blends under Thermocycling: Implications for Clinical Durability. Acta Stomatol Croat 2023; 57:286-299. [PMID: 38283309 PMCID: PMC10812913 DOI: 10.15644/asc57/4/1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 12/01/2023] [Indexed: 01/30/2024] Open
Abstract
Objectives To optimize the therapeutic usefulness of aligners, it is crucial to understand how their mechanical properties alter with time. Materials and methods Specimens from four different brands, including Duran+, CA® Pro, Zendura A, and Zendura FLX, were produced for material testing of thermoplastic orthodontic aligners (TOA) using dimensions measuring 4mm x 10mm. Each brand's 24 samples were split into three groups as follows: G1 being thermoformed, G2 being thermoformed and underwent 500 thermocycles (simulating 7 days), and G3 being thermoformed and underwent 1000 thermocycles (simulating 14 days). Surface roughness, modulus of elasticity in bending, and spectrophotometry were used to assess the effect of aging on TOAs. Results After 1000 thermocycles, Duran+ had the highest modulus of elasticity and differed statistically from all other groups. The intragroup comparison showed that only Duran+'s elastic modulus significantly changed after 1000 thermocycles in comparison with the control group. Surface roughness values (Ra), did not statistically differ among brands or thermocycling group measures. The change in chemical properties was not significant in any brand. Conclusion One-layer PETG (Duran+) failed to demonstrate stability after in vitro aging, thus suggesting that clinicians should be aware of the change in mechanical properties when using one-layer PETG (Duran +) in a 2 weeks regime.
Collapse
Affiliation(s)
- Luka Šimunović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | | | | | - Ivana Bačić
- Forensic Science Centre "Ivan Vučetić", Ministry of the Interior, Ilica 351, 10000 Zagreb, Croatia
| | - Senka Meštrović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| |
Collapse
|
17
|
Khashashneh M, Ratnayake J, Choi JJE, Mei L, Lyons K, Brunton P. The Effect of 10% Carbamide Peroxide Dental Bleaching on the Physical Properties of Invisalign Aligners: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16114125. [PMID: 37297258 DOI: 10.3390/ma16114125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 05/16/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
The high aesthetic demands of patients have increased their requests to align their teeth using clear aligners, including Invisalign. Patients also want to have their teeth whitened for the same purpose; the use of Invisalign as a bleaching tray at night has been reported in few studies. However, whether 10% carbamide peroxide affects the physical properties of Invisalign is unknown. Therefore, the objective of this study was to evaluate the effect of 10% carbamide peroxide on the physical properties of Invisalign when used as a bleaching tray at night. Twenty-two unused Invisalign aligners (Santa Clara, CA, USA) were used to prepare 144 specimens to test their tensile strength, hardness, surface roughness, and translucency. The specimens were divided into four groups: a testing group at baseline (TG1), a testing group after application of bleaching material at 37 °C for 2 weeks (TG2), a control group at baseline (CG1), and a control group after immersion in distilled water at 37 °C for 2 weeks (CG2). Statistical analysis was conducted using a paired t-test, Wilcoxon signed rank test, independent samples t-test, and Mann-Whitney test to compare samples in CG2 to CG1, TG2 to TG1, and TG2 to CG2. Statistical analysis showed no statistically significant difference between the groups for all physical properties, except for hardness (p-value < 0.001) and surface roughness (p-value = 0.007 and p-value < 0.001 for the internal and external surface roughness, respectively), which revealed a reduction in hardness values (from 4.43 ± 0.86 N/mm2 to 2.2 ± 0.29 N/mm2) and an increase in surface roughness (from 1.6 ± 0.32 Ra to 1.93 ± 0.28 Ra and from 0.58 ± 0.12 Ra to 0.68 ± 0.13 Ra for the internal and external surface roughness, respectively) after 2 weeks of dental bleaching. Results showed that Invisalign can be used for dental bleaching without excessive distortion or degradation of the aligner material. However, future clinical trials are required to further assess the feasibility of using Invisalign for dental bleaching.
Collapse
Affiliation(s)
- Majd Khashashneh
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, P.O. Box 56, Dunedin 9054, New Zealand
- Faculty of Dentistry, Jordan University of Science and Technology, P.O. Box 3030, Irbid 22110, Jordan
| | - Jithendra Ratnayake
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, P.O. Box 56, Dunedin 9054, New Zealand
| | - Joanne Jung Eun Choi
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, P.O. Box 56, Dunedin 9054, New Zealand
| | - Li Mei
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, P.O. Box 56, Dunedin 9054, New Zealand
| | - Karl Lyons
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, P.O. Box 56, Dunedin 9054, New Zealand
| | - Paul Brunton
- DVCA, Curtin Perth, Curtin University, Bentley, WA 6102, Australia
| |
Collapse
|
18
|
Šimunović L, Blagec T, Meštrović S. Resistance of PETG Materials on Thermocycling and Brushing. Dent J (Basel) 2023; 11:dj11050135. [PMID: 37232786 DOI: 10.3390/dj11050135] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/11/2023] [Accepted: 05/12/2023] [Indexed: 05/27/2023] Open
Abstract
The aim was to assess the impact of thermocycling and brushing on the surface roughness and mass of PETG material-the most commonly used for orthodontic retainers. A total of 96 specimens were exposed to thermocycling and brushing with three different kinds of toothbrushes depending on the number and thickness of the bristles. Surface roughness and mass were evaluated three times: initially, after thermocycling, and after brushing. In all four brands, both thermocycling and brushing increased surface roughness significantly (p < 0.001), with Biolon having the lowest and Track A having the highest. In terms of brushing, only Biolon samples showed statistically significant increased roughness after brushing with all three types of brushes, in comparison to Erkodur A1, where differences were not statistically significant. Thermocycling increased the mass of all samples, but a statistically significant difference was found only in Biolon (p = 0.0203), while after brushing, decreased mass was found in all specimens, statistically significant only in Essix C+ (CS 1560: p = 0.016). PETG material showed instability when exposed to external influences- thermocycling produced an increase in roughness and mass, and brushing mostly caused an increase in roughness and decrease in mass. Erkodur A1 demonstrated the greatest stability, whereas Biolon demonstrated the lowest.
Collapse
Affiliation(s)
- Luka Šimunović
- Department of Orthodontics, School of Dental Medicine Zagreb, University of Zagreb, 10000 Zagreb, Croatia
| | - Tadeja Blagec
- Department of Orthodontics, School of Dental Medicine Zagreb, University of Zagreb, 10000 Zagreb, Croatia
| | - Senka Meštrović
- Department of Orthodontics, School of Dental Medicine Zagreb, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
19
|
Quinzi V, Orilisi G, Vitiello F, Notarstefano V, Marzo G, Orsini G. A spectroscopic study on orthodontic aligners: First evidence of secondary microplastic detachment after seven days of artificial saliva exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 866:161356. [PMID: 36603638 DOI: 10.1016/j.scitotenv.2022.161356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 12/20/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Clear orthodontic aligners have recently seen increasing popularity. The thermoplastic materials present several advantages, even if it is known that all plastic products can be subjected to environmental and mechanical degradation, leading to the release of microplastics (MPs). Their ingestion could cause oxidative stress and inflammatory lesions. This study aims to evaluate the potential detachment of MPs by clear aligners due to mechanical friction simulated with a 7-day protocol in artificial saliva. The study was performed on orthodontic clear aligners from different manufacturers: Alleo (AL); FlexiLigner (FL); F22 Aligner (F22); Invisalign® (INV); Lineo (LIN); Arc Angel (ARC), and Ortobel Aligner (OR). For each group, two aligners were immersed in artificial saliva for 7 days and stirred for 5 h/day, simulating the physiological teeth mechanical friction. After 7 days, the artificial saliva was filtered; then, filters were analyzed by Raman Microspectroscopy (RMS) and Scanning Electron Microscopy (SEM), respectively to chemically identify the polymeric matrix and to measure the number and size of the detected MPs. RMS spectra revealed that AL, FL, LIN, ARC, and OR aligners were composed by polyethylene terephthalate, while F22 and INV ones by polyurethane. SEM analysis showed that the highest number of MPs was found in ARC and the lowest in INV (p < 0.05). As regards MPs' size, no statistically significant difference was found among groups, with most MPs ranging from 5 to 20 μm. Noteworthy, a highly significant correlation (p < 0.0001) was highlighted between the distribution of MPs size and the different typologies of aligners. This in vitro study highlighted for the first time the detachment of MPs from clear aligners due to mechanical friction. This evidence may represent a great concern in the clinical practice since it could impact human general health.
Collapse
Affiliation(s)
- Vincenzo Quinzi
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giulia Orilisi
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Flavia Vitiello
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Valentina Notarstefano
- Università Politecnica delle Marche, Dipartimento di Scienze della Vita e dell'Ambiente, Via Brecce Bianche, 60131 Ancona, Italy
| | - Giuseppe Marzo
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giovanna Orsini
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy.
| |
Collapse
|
20
|
Ferlito T, Hsiou D, Hargett K, Herzog C, Bachour P, Katebi N, Tokede O, Larson B, Masoud MI. Assessment of artificial intelligence-based remote monitoring of clear aligner therapy: A prospective study. Am J Orthod Dentofacial Orthop 2023:S0889-5406(23)00076-8. [PMID: 36997411 DOI: 10.1016/j.ajodo.2022.11.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 11/01/2022] [Accepted: 11/01/2022] [Indexed: 03/29/2023]
Abstract
INTRODUCTION Artificial intelligence remote monitoring of clear aligner therapy has recently gained popularity. It uses deep learning algorithms on a patient's mobile smartphone to determine readiness to progress to the next aligner (ie, GO vs NO-GO) and identify areas in which the teeth are not tracking with the clear aligners. This study aimed to assess the repeatability of the Go or No-Go instructions provided by the application and to determine the 3-dimensional discrepancies that constitute an unseat. METHODS Thirty patients in treatment with clear aligners at an academic clinic were scanned twice using a remote monitoring application on a smartphone, and the results were compared. Gauge repeatability and reproducibility analysis were performed. Intraoral and remote monitoring scans were obtained on the same day from 24 additional clear aligner patients that completed treatment using their final aligners. The intraoral scan after using the final aligner and the stereolithography file of the planned position at the final aligner was compared with measure the maximum discrepancies between the actual and planned position of the teeth. RESULTS Gauge compatibility of 44.7% was noted. In total 83.3% of patient instructions agreed between Scan 1 and 2, but 0% agreed completely on which and/or how many teeth had tracking issues. Patients who received GO instruction had mean greatest discrepancies of 1.997 mm, 1.901 mm, 0.530 mm, 8.911°, 7.827°, and 7.049° in mesiodistal, buccolingual, occlusogingival, tip, torque, and rotational dimensions, respectively. These discrepancies were not significantly different from patients receiving NO-GO instruction (1.771 mm, 1.808 mm, 0.606 mm, 8.673°, 8.134°, and 6.719° for the corresponding categories). CONCLUSIONS Despite the study's limitations, these findings suggest concerns with the consistency of remote monitoring instructions because of gauge compatibility over the industry standard. Similarly, large discrepancies in tooth position for patients receiving GO and NO-GO instruction suggest that artificial intelligence decisions were inconsistent with quantitative findings.
Collapse
|
21
|
Effect of aging on color, gloss and surface roughness of CAD/CAM composite materials. J Dent 2023; 130:104423. [PMID: 36642325 DOI: 10.1016/j.jdent.2023.104423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/17/2022] [Accepted: 01/11/2023] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES To assess the effect of aging procedures on color, gloss and surface roughness of CAD/CAM composite materials. METHODS 6 CAD/CAM composite materials (Brilliant CRIOS, Cerasmart, Lava Ultimate, Tetric CAD, Shofu Block HC, Grandio Blocs) were tested. 10 CAD/CAM fabricated specimens of each material polished according to manufacturers' recommendations, were subjected to one of the following aging procedures; immersion in coffee (30 days, 37οC), water thermocycling (5000 cycles, 5-55 °C) and photoaging (150,000 kJ/m2). Color, gloss and surface roughness measurements were performed before and after aging and the respective changes were calculated. Kruskal-Wallis tests, paired t-tests, one-way ANOVA and Bonferroni post-hoc tests were used for statistical analysis (a = 0.05). RESULTS Color changes ranged from 3.03 to 4.13 after coffee immersion, from 1.33 to 2.55 after thermocycling and from 1.02 to 2.75 after photoaging. No statistically significant differences for ΔE*ab were found among materials after coffee immersion and thermocycling (p>0.05). Gloss changes ranged from -5.7 to -1.6 GU after coffee immersion, from -2.3 to 0.1 GU after thermocycling and from -4.4 to 0.5 GU after photoaging. No significant differences in gloss changes were found among materials after aging (p>0.05). Tetric CAD demonstrated the significantly lower gloss and the higher surface roughness after polishing. Except for gloss after thermocycling, aging procedures caused significant alteration of gloss and surface roughness parameters from baseline levels. CONCLUSIONS Aging procedures caused perceptible but acceptable color changes and small but visible gloss changes, while surface roughness parameters of the tested CAD/CAM composite materials were significantly affected by aging. CLINICAL SIGNIFICANCE Aging procedures affected CAD/CAM composite materials indicating that these materials may be prone to color and surface alterations in the oral environment that could compromise the esthetics and the performance of the restorations. Clinical studies are needed to investigate the long-term behavior of the newly introduced CAD/CAM materials.
Collapse
|
22
|
Iliadi A, Enzler V, Polychronis G, Peltomaki T, Zinelis S, Eliades T. Εffect of cleansers on the composition and mechanical properties of orthodontic aligners in vitro. Prog Orthod 2022; 23:54. [PMID: 36517652 PMCID: PMC9751251 DOI: 10.1186/s40510-022-00449-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 11/09/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The aim of the study was to investigate the effect of three aligner cleaners on the composition and mechanical properties of two types of orthodontic aligners. MATERIALS AND METHODS The cleaners tested were two alkaline peroxide solutions (Retainer Brite-RB; Retainer Cleaner-RC) and one peroxide-free (Steraligner-ST) and the aligners Clear Aligner (C, polyester) and Invisalign (I, polyester-urethane). The aligners were immersed in the cleaner solutions as instructed every day (15 min for RB, RC; 5 min for ST) for a two-week period. The acidity of the solutions was tested with a pH meter. The changes in the chemical composition of the aligners were studied by attenuated total-reflection Fourier transform infrared spectrometry (ATR-FTIR), while Instrumented Indentation Testing (IIT) was used for assessment of changes in Martens Hardness (HM), modulus (EIT), elastic index (nIT) and relaxation (RIT). RESULTS RB and RC were weakly acidic (pH = 6.3), whereas ST was mildly acidic (pH = 4.8). The ATR-FTIR analysis demonstrated evidence of acidic hydrolysis of C in ST and I in RB. The IIT-derived properties of I were not affected by the cleaners. However, for C a significant change was found in HM (all cleaners), nIT (all cleaners) and RIT (RB, ST). Although the chemical changes support a hydrolytic material deterioration, the results of mechanical properties may interfere with the material residual stresses during fabrication. CONCLUSIONS Caution should be exerted in the selection of aligner cleaners. The mild acidic cleanser was more aggressive to the polyester, whereas an alkaline peroxide to the polyester-urethane aligner.
Collapse
Affiliation(s)
- Anna Iliadi
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Vera Enzler
- grid.7400.30000 0004 1937 0650Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| | - Georgios Polychronis
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Timo Peltomaki
- grid.502801.e0000 0001 2314 6254Department of Oral and Maxillofacial Diseases, Tampere University Hospital, Tampere, Finland Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland ,grid.410705.70000 0004 0628 207XDepartment of Oral and Maxillofacial Diseases, Kuopio University Hospital, Kuopio, Finland ,grid.9668.10000 0001 0726 2490Faculty of Health Sciences, Institute of Dentistry, University of Eastern Finland, Kuopio, Finland
| | - Spiros Zinelis
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- grid.7400.30000 0004 1937 0650Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| |
Collapse
|
23
|
Warnecki M, Sarul M, Kozakiewicz M, Zięty A, Babiarczuk B, Kawala B, Jurczyszyn K. Surface Evaluation of Aligners after Immersion in Coca-Cola and Orange Juice. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15186341. [PMID: 36143665 PMCID: PMC9504463 DOI: 10.3390/ma15186341] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/09/2022] [Accepted: 09/12/2022] [Indexed: 05/31/2023]
Abstract
Orthodontic removable appliances made of transparent thermoplastic materials-aligners-are becoming increasingly popular in contemporary orthodontic practice. It is important for the clinician to fully understand the mechanical properties and behavior of the appliance used. Because of that, the aim of our study was to investigate the changes in aligner surface after immersion in Coca-Cola and orange juice. For surface evaluation, fractal analysis, texture analysis, and wetting angle measurement were performed. Statistically significant changes were found between some of the groups in the fractal dimension analysis. In texture analysis, all but one intergroup comparison showed statistically significant differences. For wetting angle assessment, statistically significant differences were found. These were, however, more numerous when assessing glycol droplets, rather than water droplets. Fractal dimension analysis confirmed a correlation between the intensity of changes in the aligner surface with immersion time in the liquids assessed. Texture analysis showed a high sensitivity to the changes in aligner surface. It failed, however, to reveal changes relative to immersion time. Wetting angle analysis revealed aligner surface degradation for Coca-Cola. It did not, however, prove the dependence of the intensity of this degradation as a function of time. Both Coca-Cola and orange juice can cause aligner surface degradation.
Collapse
Affiliation(s)
- Maciej Warnecki
- Independent Researcher, Niemodlińska 63, 45-864 Opole, Poland
| | - Michał Sarul
- Department of Integrated Dentistry, Wrocław Medical University, 50-425 Wrocław, Poland
| | - Marcin Kozakiewicz
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland
| | - Anna Zięty
- Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-372 Wrocław, Poland
| | - Bartosz Babiarczuk
- Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-372 Wrocław, Poland
| | - Beata Kawala
- Department of Dentofacial Orthopedics and Orthodontics, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| | - Kamil Jurczyszyn
- Department of Oral Surgery, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
| |
Collapse
|
24
|
Pratsinis H, Papageorgiou SN, Panayi N, Iliadi A, Eliades T, Kletsas D. Cytotoxicity and estrogenicity of a novel 3-dimensional printed orthodontic aligner. Am J Orthod Dentofacial Orthop 2022; 162:e116-e122. [PMID: 35842359 DOI: 10.1016/j.ajodo.2022.06.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Orthodontic aligners printed with in-office 3-dimensional (3D) procedures have been described, but no data on their biocompatibility exist. This study investigates the cytotoxicity and estrogenicity of a 3D-printed orthodontic aligner by assessing its biological and behavioral effects. METHODS Ten sets of 1 type of aligner were immersed in sterile deionized water for 14 days, and the cytotoxicity and estrogenicity of released factors were assessed via MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assays on human gingival fibroblasts and the estrogen-sensitive MCF-7 and the estrogen-insensitive MDA-MB-231 breast cancer cell lines. 17β-Estradiol and bisphenol-A were used as positive controls. The statistical analysis of data was performed with generalized linear models at a 0.05 level of significance. RESULTS No signs of cytotoxicity were seen for the aligner samples for concentrations (v/v) of 20% (P = 0.32), 10% (P = 0.79), or 5% (P = 0.76). The antioxidant activity expressed as the capacity to reduce intracellular levels of reactive oxygen species was not affected in the aligner samples (P = 0.08). No significant estrogenicity was induced by the aligner samples compared with eluents from the negative control for both MCF-7 (P = 0.65) and MDA-MB-231 (P = 0.78). As expected, 17β-Estradiol and bisphenol-A stimulated MCF-7 cell proliferation, whereas no effect was observed on MDA-MB-231 cells. CONCLUSIONS In conclusion, if any factors were released during the 14-day aging of 3D-printed aligners in water, these were not found to be cytotoxic for human gingival fibroblasts and did not affect their intracellular reactive oxygen species levels. Moreover, no estrogenic effects of these putative eluates were observed based on an E-screen assay.
Collapse
Affiliation(s)
- Harris Pratsinis
- Laboratory of Cell Proliferation and Ageing, Institute of Biosciences and Applications, National Center for Scientific Research "Demokritos," Athens, Greece
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Nearchos Panayi
- Department of Dentistry, European University Cyprus, Nicosia, Cyprus; Private practice, Limassol, Cyprus
| | - Anna Iliadi
- Department of Dental Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| | - Dimitris Kletsas
- Laboratory of Cell Proliferation and Ageing, Institute of Biosciences and Applications, National Center for Scientific Research "Demokritos," Athens, Greece
| |
Collapse
|
25
|
Ammann R, Tanner C, Schulz G, Osmani B, Nalabothu P, Töpper T, Müller B. Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution. J Med Imaging (Bellingham) 2022; 9:031509. [PMID: 36267352 PMCID: PMC9574087 DOI: 10.1117/1.jmi.9.3.031509] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 05/31/2022] [Indexed: 07/02/2024] Open
Abstract
PURPOSE The morphology of a polymer aligner, designed according to an orthodontic treatment plan, determines clinical outcomes. A fundamental element of orthodontic tooth movement with aligner treatment is the fit of the aligner's surface to the individual teeth. Gaps between the aligner and teeth do occur because current aligner fabrication is not capable of completely reproducing the complex anatomy of the individual denture. Our study aims at a quantitative three-dimensional assessment of the fit between optically transparent aligners placed on a polymeric model of the upper dental arch for two thermofoil thicknesses at preselected thermoforming temperatures. APPROACH Using an intraoral scan of a subject's upper dental arch, eight models were printed using a stereolithographic system. A series of eight NaturAligners® was manufactured with a pressure molding process, using thermofoils with thicknesses of 550 and 750 μ m and preselected process temperatures between 110°C and 210°C. These aligners placed on the corresponding models were imaged by an advanced micro computed tomography system. The aligners and the models were segmented to extract the gaps and aligners' local thicknesses as a function of the processing temperature for the two foil thicknesses. RESULTS The results indicate that the aligners show a better fit when the foils are processed at higher temperatures. Nevertheless, processing temperatures can be kept below 150°C, as the gain becomes negligible. Thermal processing reduces the average thickness of the aligners to 60% with respect to the planar starting foil. These thickness distributions demonstrate that the aligners are generally thicker on the occlusal surfaces of molars and premolars but thinner around the incisors and buccal as well as on oral surfaces. CONCLUSIONS Hard x-ray tomography with micrometer resolution is a powerful technique employed to localize the gaps between aligners and teeth, and it also enables film thickness measurements after thermoforming. The thicker film on the occlusal surfaces is most welcome because of aligner abrasion during wear. The NaturAligner® surfaces consist of a 25 - μ m -thin cellulose layer, and thus the microplastics released via abrasion of less than this thickness are expected to be substantially less critical than for other commercially available, optically transparent aligners.
Collapse
Affiliation(s)
- Rémi Ammann
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Christine Tanner
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Georg Schulz
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Core Facility Micro- and Nanotomography, Department of Biomedical Engineering, Allschwil, Switzerland
| | - Bekim Osmani
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Prasad Nalabothu
- University Hospital Basel, Department of Oral and Craniomaxillofacial Surgery, Basel, Switzerland
- University of Basel, Center for Dental Medicine, Department of Pediatric Oral Health and Orthodontics, Basel, Switzerland
| | - Tino Töpper
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Bert Müller
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| |
Collapse
|
26
|
In vitro study of structural and mechanical properties of latex and non-latex intermaxillary orthodontic elastics. J Orofac Orthop 2022; 84:111-122. [PMID: 35441842 DOI: 10.1007/s00056-022-00395-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Accepted: 03/04/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE We evaluated bacterial endotoxin adhesion, superficial micromorphology and mechanical properties of latex and non-latex intermaxillary orthodontic elastics. METHODS To quantify the adhered bacterial endotoxin, elastics were divided into 5 groups: experimental (n = 12) latex and non-latex elastics, previously contaminated by an endotoxin solution, negative control (n = 6) latex and non-latex elastics without contamination, and positive control (n = 6) stainless steel specimens (metallic replicas), contaminated by an endotoxin solution. In parallel, the structural micromorphology (n = 6) and surface roughness of latex and non-latex intermaxillary orthodontic elastics were assessed using confocal laser microscopy. Force degradation (g) and deformation of the internal diameter change (mm) were also evaluated. Structural micromorphology, surface roughness (µm), force degradation (g) and internal diameter (mm) change were evaluated at time 0 and after 24 and 72 h in a deformation test. Data were analyzed by the Shapiro-Wilk, Kruskal-Wallis, Dunn, ANOVA and Bonferroni tests (α = 5%). RESULTS Endotoxin adhered similarly to both types of elastics with scores of 3 (> 1.0 EU/mL). The surface microstructure of both types of elastics showed irregularities and porosities at all times. Initially, the latex elastics had a higher surface roughness (p < 0.001) than the non-latex ones. After 24 h loading, surface roughness of the latex elastics was significantly reduced (p < 0.001), while after 72 h, the values were similar for both types (p > 0.05). The non-latex elastics had significantly higher force generation values (p < 0.05) at 0, 24 and 72 h compared with the latex elastics, although there was a significant reduction (p < 0.001) in force over time for both elastics. Despite similar initial values, non-latex elastics had a significantly larger internal diameter (p < 0.001) after the loading periods of 24 and 72 h compared with the latex elastics. CONCLUSION Both elastics showed high affinity with endotoxin and microstructural irregularities of their surface. The non-latex elastics generated higher force values but demonstrated greater deformation of the internal diameter after loading.
Collapse
|
27
|
Performance of Rigid and Soft Transfer Templates Using Viscous and Fluid Resin-Based Composites in the Attachment Bonding Process of Clear Aligners. Int J Dent 2022; 2022:1637594. [PMID: 35190741 PMCID: PMC8858075 DOI: 10.1155/2022/1637594] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 01/09/2022] [Accepted: 01/17/2022] [Indexed: 12/17/2022] Open
Abstract
Objectives The study aims at assessing the accuracy of the process of attachment bonding in aligner treatments. The analysis leads to the error estimation in the faithful reproduction of master model attachments using two types of transfer templates and two light-curing resin-based composites usually used in orthodontics. Methods The authors have used two transfer templates made of two different materials. The first, named Leone-biocompatible thermoforming material hard/soft, has a lower Young's modulus and is labelled as soft, while the other, named Leone-biocompatible thermoforming material, is marked as rigid. The resin-based composites possess different mechanical and rheological properties. Specifically, Transbond™ XT Light Cure Paste Adhesive, 3M has a higher viscosity than the TetricEvoflow, Ivoclar Vivadent, a flowable nanohybrid composite. The authors attempt to estimate the performance ranking between the four possible couples obtained by combining the two light-curing resin-based composites and transfer templates. Each combination was repeated in six models and compared with twelve master models, resulting in 36 total samples. A 3-D laser scanner is used to generate a digital model of each model. The comparison between digital models is the base for a comparative assessment in terms of relative and absolute error. The relative error is estimated using scalar performance indicators ranging from 0 to 1, where 1 indicates the optimum matching. The absolute error estimated from the mean square error between the coordinates of each digital model yields the reproduction accuracy in micrometer. Furthermore, the authors attempted to assess the error distribution by evaluating the point-by-point difference between the digital models. Results This analysis aims at localizing the sources of error in the considered models. The use of Transbond™ XT Light Cure Paste Adhesive, 3M with a rigid transfer template is always associated with significant accuracy and minor dispersion. However, in a few instances, using the soft template or the flowable resin-based composite can lead to bad performances. Significance. The data processing bestowed the following performance ranking from the first with lower reproduction error to the last characterized by the worst performance: (1) attachments bonding with rigid template and Transbond™ XT Light Cure Paste Adhesive, 3M, (2) attachments bonding with soft template and Transbond™ XT Light Cure Paste Adhesive, 3M, (3) attachments bonding with rigid template and TetricEvoflow, Ivoclar Vivadent, and (4) attachments bonding with soft template and TetricEvoflow, Ivoclar Vivadent.
Collapse
|
28
|
Bakdach WMM, Haiba M, Hadad R. Changes in surface morphology, chemical and mechanical properties of clear aligners during intraoral usage: A systematic review and meta-analysis. Int Orthod 2022; 20:100610. [DOI: 10.1016/j.ortho.2022.100610] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 01/05/2022] [Accepted: 01/08/2022] [Indexed: 10/19/2022]
|
29
|
ERGEL D, SADRY S, OK U. Ortodontide Kullanılan Şeffaf Plakların Su Emilimlerinin ve Renklenmelerinin Değerlendirmesi. İSTANBUL GELIŞIM ÜNIVERSITESI SAĞLIK BILIMLERI DERGISI 2021. [DOI: 10.38079/igusabder.1010796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
30
|
Pratto I, Busato MCA, Bittencourt PRS. Thermal and mechanical characterization of thermoplastic orthodontic aligners discs after molding process. J Mech Behav Biomed Mater 2021; 126:104991. [PMID: 34864573 DOI: 10.1016/j.jmbbm.2021.104991] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 11/17/2021] [Accepted: 11/18/2021] [Indexed: 10/19/2022]
Abstract
Polymeric aesthetic aligners were introduced in orthodontics as an innovative alternative to fixed appliances, however, their compositions and the thermal molding process may influence the biomechanical characteristics of these aligners. In this study four different clear aligner brands were used, ACE 035 Essix, C + Essix, Crystal 0.75 and Crystal 1.0, whose aim was to identify the thermal-processing influence on the mechanical and physicochemical properties of these materials, and to suggest a orthodontic sequence of wear for these appliances to achieve more effective treatment results. For the tensile tests the sample size calculation was based on probability distributions from the F test. The effect size used was 0.3, type 1 error of 0.05. Statistical Yield strength and Young's Modulus results were evaluated using the Shapiro-Wilk test. The groups were compared using the parametric test of analysis of variance, with Tukey post-test. Differences were statistically considered at the p < 0.05. The Infrared spectroscopy analysis showed no changes in the samples' chemical structure after thermal-processing. However, in the polypropylene aligner, differences were verified in the region attributed to the crystalline phase. Differential Scanning Calorimetry analysis for the same sample showed a crystallinity fraction decrease due to relaxation between polymer chains after molding. In the tensile tests evaluated, the tensile strength and 'Young's modulus presented higher values for aligners containing 100% polyethylene terephthalate glycol. Performing an analogy exercise of the properties of orthodontic wires used in conventional fixed appliances and, relating them to orthodontic plastics, aligners composed of different materials and/or thicknesses could be used in increasing sequence in terms of the modulus of elasticity, starting with C+, which has a lower elastic modulus value, using the ACE 035 as an intermediate and finishing with the Crystal 0.75 and 1.0, providing the desired stiffness to the aligners for the final phase.
Collapse
Affiliation(s)
- Isabella Pratto
- Universidade Estadual do Oeste do Paraná (UNIOESTE), Departamento de Odontologia, ZIP 85819-110, Cascavel, Paraná, Brazil
| | - Mauro Carlos Agner Busato
- Universidade Estadual do Oeste do Paraná (UNIOESTE), Departamento de Odontologia, ZIP 85819-110, Cascavel, Paraná, Brazil
| | - Paulo Rodrigo Stival Bittencourt
- Universidade Tecnológica Federal do Paraná (UTFPR), Departamento Acadêmico de Química, Bloco I4, ZIP 85884-000, Medianeira, Paraná, Brazil.
| |
Collapse
|
31
|
Zinelis S, Panayi N, Polychronis G, Papageorgiou SN, Eliades T. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers. Orthod Craniofac Res 2021; 25:336-341. [PMID: 34569692 PMCID: PMC9544566 DOI: 10.1111/ocr.12537] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 12/11/2022]
Abstract
OBJECTIVE The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. MATERIALS AND METHODS Five 3D printers (Ka:rv LP 550, Swinwon; "KAR"), (L120, Dazz 3D; "L12"), (MiiCraft 125, Miicraft Jena; "MIC"), (Slash 2, Uniz; "SLS") and (Pro 95, SprintRay; "PRO") were used to prepare orthodontic aligners with dental resin (Tera Harz TC-85DAW, Graphy). The central incisors of each aligner were cut, prepared and evaluated in terms of Martens-Hardness (HM), indentation-modulus (EIT ) and elastic-index (ηIT ) as per ISO14577-1:2002. Force-indentation curves were recorded and differences among printers were checked with generalized linear regressions (alpha=5%). RESULTS Statistically significant differences were seen for all mechanical properties (P < .05), which were in descending order: HM (N/mm2 ) as median (Interquartile Range [IQR]): SLS 108.5 (106.0-112.0), L12 103.0 (102.0-107.0), KAR 101.5 (97.5-103.0), MIC 100.0 (97.5-101.5) and PRO 94.0 (93.0-96.0); EIT (MPa) as mean (Standard Deviation [SD]): SLS 2696.3 (124.7), L12 2627.8 (73.5), MIC 2566.2 (125.1), KAR 2565.0 (130.2) and PRO 2491.2 (53.3); and ηIT (%) as median (IQR): SLS 32.8 (32.3-33.1), L12 31.6 (30.8-32.3), KAR 31.3 (30.9-31.9), MIC 30.5 (29.9-31.2) and PRO 29.5 (29.1-30.0). Additionally, significant differences existed between liquid crystal display (LCD) and digital light processing (DLP) printers for HM (P < .001), EIT (P = .002) and ηIT (P < .001), with aligners from the former having higher values than aligners from the latter printer. CONCLUSION Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.
Collapse
Affiliation(s)
- Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | | | - Georgios Polychronis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
32
|
Influence of a bleaching agent on surface and mechanical properties of orthodontic thermoplastic retainer materials : An in vitro study. J Orofac Orthop 2021; 83:332-338. [PMID: 34170331 DOI: 10.1007/s00056-021-00312-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Accepted: 04/24/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To investigate the effect of a tooth whitening agent on surface roughness, surface hardness, and force delivery properties of polyethylene terephthalate glycol (PETG) thermoplastic retainer materials of two different thicknesses. METHODS PETG sheets (1 mm and 1.5 mm) were thermoformed over a 30 × 60 × 10 mm3 rectangular stone model. Surface hardness, surface roughness, and results of a three-point bending test were evaluated before and after treatment (5 h daily for 14 days) with a 15% carbamide peroxide home bleaching agent. Data were analyzed using an independent sample t‑test. RESULTS Exposure of PETG specimens to the bleaching agent for 14 days significantly reduced surface hardness and increased surface roughness of samples of both thicknesses. The magnitude of force at different deflection points decreased significantly in the 1.5 mm thickness specimens treated with the bleaching agent, but no significant change was observed in the specimens with 1 mm thickness. CONCLUSION Use of a home bleaching agent could have adverse effects on surface roughness and hardness of PETG materials leading to reduced survival time of thermoplastic orthodontic retainers.
Collapse
|
33
|
Isman O, Isman E. Identification of various orthodontic materials as foreign bodies via panoramic radiography, cone beam computed tomography, magnetic resonance imaging, and ultrasonography: an in vitro study. Oral Radiol 2021; 37:524-530. [PMID: 34037939 DOI: 10.1007/s11282-021-00537-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Accepted: 05/08/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVES We evaluated the in vitro detection sensitivity of orthodontic materials (serving as foreign bodies) using panoramic radiography, cone beam computed tomography (CBCT), magnetic resonance imaging (MRI), and ultrasonography. METHODS Five different orthodontic materials served as foreign bodies: titanium-molybdenum alloy wire (TMA; ORMCO, Orange, CA, USA; 0.017 × 0.025 in in cross-sectional dimensions and 1 cm long); stainless steel bracket tooth #34 (American Orthodontics, Sheboygan, WI, USA); a monocrystalline, sapphire ceramic bracket tooth #34 (Skyortho Dental Supplies Medical, China); a polycrystalline alumina clear bracket, Damon clear bracket tooth #34 (ORMCO); and a 1 × 1 × 0.1 cm polyurethane-based thermoplastic material, Invisalign clear aligner (Align Technology, San Jose, CA, USA). Panoramic radiography, CBCT, MRI, and ultrasonography were used, and four observers scored all findings independently. RESULTS The TMA and stainless steel bracket were visualised in all fields by panoramic radiography and CBCT. The sapphire and Damon brackets were very clear on CBCT. The Invisalign in air was evident only on CBCT. MRI was unable to identify any material in muscle. Ultrasonography detected the TMA, sapphire bracket, and the Invisalign in muscle but only the TMA on bone. CONCLUSIONS Panoramic radiography does not reveal nonmetallic orthodontic equipment in air and reveals them only poorly in muscle. CBCT was the optimal imaging modality for all materials in all fields except for the Invisalign in muscle and bone. CBCT was the only method that revealed the Invisalign in air. MRI and ultrasonography should be used to detect orthodontic materials in muscle.
Collapse
Affiliation(s)
- Ozlem Isman
- Vocational High School of Health Service, Gaziantep University, Gaziantep, 27310, Şehitkamil/Gaziantep, Turkey.
| | - Eren Isman
- Private Practice, Gaziantep, 27310, Turkey
| |
Collapse
|
34
|
The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva. Sci Rep 2021; 11:10052. [PMID: 33980889 PMCID: PMC8115163 DOI: 10.1038/s41598-021-89425-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 04/20/2021] [Indexed: 11/08/2022] Open
Abstract
Numerous factors can influence the force exerted by clear aligners on teeth. This study aimed to investigate the stability of the force delivered by two different material appliances. 90 clear aligners with 2 materials and three different activations were designed and fabricated. Then, a device was employed to measure the force generated by the two types of PET-G material appliances immersed in artificial saliva for 0, 3, 7, 10, 14 days. Scanning electron microscopy was applied to observe the morphologic alterations on the aligner surfaces, respectively. The forces generated by different activation appliance exhibited differently, 0.0 mm < 0.1 mm < 0.2 mm. In addition, increasing the immersion times and the orthodontic force also decreased, but the forces decreased differently. Compared with the forces of conventional PETG appliances with 0.20 mm activation, the modified PETG appliances with the same activation exhibited significantly higher mean force. When comparing the mean force for modified PETG appliances after 10 and 14 days with conventional PETG appliances, the delivery forces exhibited significant differences (P < 0.05). The force delivered by both materials decreased obviously following artificial saliva immersion, and the force generated by modified aligners exhibited better stability than conventional aligners.
Collapse
|
35
|
Chan E, Panayi N, Polychronis G, Papageorgiou SN, Zinelis S, Eliades G, Eliades T. In-house 3D-printed aligners: effect of in vivo ageing on mechanical properties. Eur J Orthod 2021; 44:51-55. [PMID: 33950232 DOI: 10.1093/ejo/cjab022] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To investigate alterations in the mechanical properties of in-house three-dimensional (3D) printed orthodontic aligners after intraoral ageing. MATERIALS AND METHODS Sixteen 3D-printed aligners (TC-85DAC resin, Graphy, Seoul, Korea) were used for the purpose of the study, which were divided into 10 control (not used) aligners and 6 materials retrieved from 4 patients after 1-week service (retrieved group). Samples from the control group were analysed by attenuated total reflectance-Fourier-transform infrared (ATR-FTIR) spectroscopy. Samples from control/retrieved groups were embedded resin and subjected to instrumented indentation testing (IIT) to record force-indentation depth curves, calculating the following (as per ISO 14577-1, 2002 standard): Martens hardness (HM), indentation modulus (EIT), and elastic index (ηIT), and the indentation relaxation index (RIT). Differences between control and retrieved 3D-printed aligners were checked with Mann-Whitney/t-tests at an alpha = 5%. RESULTS ATR-FTIR analysis showed that aligners were made of a vinyl ester-urethane material. The results of the IIT testing were: HM (control: median 91.5 N/mm2, interquartile range [IQR] 88.0-93.0/as-retrieved: median 90.5 N/mm2, IQR 89.0-93.0); EIT (control, mean 2616.3 MPa, standard deviation [SD] 107.0 MPa/retrieved, mean 2673.2 MPa, SD 149.4 MPa); ηIT (control: median 28.6%, IQR 28.2-30.9%/as-retrieved: median 29.0%, IQR 28.7-29.2%); and RIT (control: median 45.5%, IQR 43.0-47.0%/as-retrieved: median 45.1%, IQR 45.0-45.3%). No differences between as-retrieved and control aligners were found for any of the mechanical properties tested (P > 0.05 in all instances). CONCLUSION The mechanical properties of the in-house 3D-printed aligners tested were not affected after 1 week in service period.
Collapse
Affiliation(s)
- Esad Chan
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | | | - Georgios Polychronis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
36
|
Putrino A, Barbato E, Galluccio G. Clear Aligners: Between Evolution and Efficiency-A Scoping Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18062870. [PMID: 33799682 PMCID: PMC7998651 DOI: 10.3390/ijerph18062870] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 02/18/2021] [Accepted: 03/02/2021] [Indexed: 12/21/2022]
Abstract
In recent years, clear aligners have diversified and evolved in their primary characteristics (material, gingival margin design, attachments, divots, auxiliaries), increasing their indications and efficiency. We overviewed the brands of aligners used in Italy and reviewed the literature on the evolution of clear aligners based on their characteristics mentioned above by consulting the main scientific databases (PubMed, Scopus, Lilacs, Google Scholar, Cochrane Library). Inclusion and exclusion criteria were established. The data were collected on a purpose-made data collection form and analyzed descriptively. From the initial 580 records, 527 were excluded because they were not related to the subject of the review or because they did not meet the eligibility criteria. The remaining 31 studies were deemed comprehensive for the purpose of the review, although the “gingival margin design” feature and “auxiliaries” tool are not well represented in the more recent literature. Current knowledge on invisible aligners allows us to have a much clearer idea of the basic characteristics of aligner systems. There remains a need to deepen the use of systems other than Invisalign™ to give greater evidence to aligners that are very different based on the characteristics analyzed here and that are very widespread on the market.
Collapse
|
37
|
ATR-FTIR Analysis of Orthodontic Invisalign ® Aligners Subjected to Various In Vitro Aging Treatments. MATERIALS 2021; 14:ma14040818. [PMID: 33572096 PMCID: PMC7914755 DOI: 10.3390/ma14040818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 02/03/2021] [Accepted: 02/04/2021] [Indexed: 11/16/2022]
Abstract
Clear and removable tooth aligners for orthodontics treatments have become an increasingly popular alternative to fixed appliances. Even if protocols suggest removing aligners before eating or drinking, most patients retain them when they drink beverages. Alterations in the material during the daily use could determine a reduction in the application forces, affecting the desired orthodontic movement; the knowledge of how this material reacts when subjected to different aging processes is mandatory to establish the predictability of the orthodontic treatment. According to this, the aim of the present study was to assess a new objective approach, coupling spectroscopic and chemometric tools, to evaluate the changes occurring in Invisalign® aligners, the most widely used brand, exposed in vitro to coffee, tea, Coca Cola® and UV radiation for 24 and 48 h. In particular, ATR-FTIR spectroscopy was utilized to characterize, at the molecular level, the chemical and color modifications in the surfaces of the appliances; the obtained data were submitted to PCA and one-way ANOVA and Tukey's multiple comparison test. Moreover, a colorimetry analysis was carried out to evaluate any changes in color and transparency. Coffee and tea samples displayed the major color changes between the tested groups. The differences highlighted in the spectral features of coffee, tea and UV-treated samples were mainly ascribable to color and transparency changes, because the chemical properties remained unaltered.
Collapse
|
38
|
Eliades T, Zinelis S. Three-dimensional printing and in-house appliance fabrication: Between innovation and stepping into the unknown. Am J Orthod Dentofacial Orthop 2021; 159:1-3. [DOI: 10.1016/j.ajodo.2020.10.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 10/20/2020] [Indexed: 10/22/2022]
|
39
|
Gordeev EG, Ananikov VP. Widely accessible 3D printing technologies in chemistry, biochemistry and pharmaceutics: applications, materials and prospects. RUSSIAN CHEMICAL REVIEWS 2020. [DOI: 10.1070/rcr4980] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
40
|
Tektas S, Thurnheer T, Eliades T, Attin T, Karygianni L. Initial Bacterial Adhesion and Biofilm Formation on Aligner Materials. Antibiotics (Basel) 2020; 9:antibiotics9120908. [PMID: 33333723 PMCID: PMC7765154 DOI: 10.3390/antibiotics9120908] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/09/2020] [Accepted: 12/11/2020] [Indexed: 12/17/2022] Open
Abstract
The present study aims to assess the initial bacterial adhesion and biofilm formation on different aligner materials. A total of four different aligner materials, CA-medium (CAM), copolyester (COP), Duran (DUR), Erkodur (ERK), were tested. Stimulated human saliva was obtained from six healthy volunteers. Salivary bacteria were harvested by centrifugation, and 1 mL of the salivary suspension was injected onto each sample surface for 2 h and 3 days, respectively. The samples were then washed twice with 5 mL 0.9% NaCl solution, and non-adherent bacteria were removed. The adherent microorganisms were dislodged from the sample surfaces after ultrasonication for 4 min in 1 mL 0.9% NaCl on ice. After the incubation of the adherent salivary bacteria under both aerobic and anaerobic conditions on Columbia blood agar plates at 37 °C and 5% CO2 and in anaerobic jars overnight, several dilutions thereof were used for the determination of CFUs. This protocol was applied three times, obtaining an average of nine independent measurements for each material group. Overall, the differences between the tested aligner materials as well as between the materials and controls were not of statistical significance (p > 0.05). Regarding initial bacterial attachment and biofilm formation, the tested aligner materials are comparable to enamel and metal orthodontic brackets and can be therefore considered for clinical use. The four tested aligner materials CAM, COP, DUR, ERK showed no significant differences in initial microbial attachment and biofilm formation of aerobic and anaerobic species compared to enamel and conventional brackets.
Collapse
Affiliation(s)
- Sibel Tektas
- Clinic of Orthodontics and Paediatric Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (S.T.); (T.E.)
| | - Thomas Thurnheer
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (T.T.); (T.A.)
| | - Theodore Eliades
- Clinic of Orthodontics and Paediatric Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (S.T.); (T.E.)
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (T.T.); (T.A.)
| | - Lamprini Karygianni
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (T.T.); (T.A.)
- Correspondence: ; Tel.: +41-44-634-3275
| |
Collapse
|
41
|
Behaviour of Human Oral Epithelial Cells Grown on Invisalign ® SmartTrack ® Material. MATERIALS 2020; 13:ma13235311. [PMID: 33255259 PMCID: PMC7727678 DOI: 10.3390/ma13235311] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/13/2020] [Accepted: 11/15/2020] [Indexed: 11/18/2022]
Abstract
Invisalign aligners have been widely used to correct malocclusions, but their effect on oral cells is poorly known. Previous research evaluated the impact of aligners’ eluates on various cells, but the cell behavior in direct contact with aligners is not yet studied. In the present study, we seeded oral epithelial cells (cell line Ca9-22) directly on Invisalign SmartTrack material. This material is composed of polyurethane and co-polyester and exhibit better mechanical characteristics compared to the predecessor. Cell morphology and behavior were investigated by scanning electron microscopy and an optical cell moves analyzer. The effect of aligners on cell proliferation/viability was assessed by cell-counting kit (CCK)-8 and 3,4,5-dimethylthiazol-2-yl-2,5-diphenyl tetrazolium bromide (MTT) assay and live/dead staining. The expression of inflammatory markers and proteins involved in epithelial barrier function was measured by qPCR. Cells formed cluster-like structures on aligners. The proliferation/viability of cells growing on aligners was significantly lower (p < 0.05) compared to those growing on tissue culture plastic (TCP). Live/dead staining revealed a rare occurrence of dead cells on aligners. The gene expression level of all inflammatory markers in cells grown on aligners’ surfaces was significantly increased (p < 0.05) compared to cells grown on TCP after two days. Gene expression levels of the proteins involved in barrier function significantly increased (p < 0.05) on aligners’ surfaces after two and seven days of culture. Aligners’ material exhibits no cytotoxic effect on oral epithelial cells, but alters their behavior and the expression of proteins involved in the inflammatory response, and barrier function. The clinical relevance of these effects has still to be established.
Collapse
|
42
|
Porojan L, Vasiliu RD, Porojan SD, Bîrdeanu MI. Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents. Polymers (Basel) 2020; 12:polym12081736. [PMID: 32756439 PMCID: PMC7464035 DOI: 10.3390/polym12081736] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 07/30/2020] [Accepted: 08/01/2020] [Indexed: 01/04/2023] Open
Abstract
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| |
Collapse
|
43
|
The use of attachments in aligner treatment: Analyzing the “innovation” of expanding the use of acid etching–mediated bonding of composites to enamel and its consequences. Am J Orthod Dentofacial Orthop 2020; 158:166-174. [DOI: 10.1016/j.ajodo.2020.04.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 04/22/2020] [Indexed: 11/23/2022]
|
44
|
Suter F, Zinelis S, Patcas R, Schätzle M, Eliades G, Eliades T. Roughness and wettability of aligner materials. J Orthod 2020; 47:223-231. [PMID: 32615846 DOI: 10.1177/1465312520936702] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The characterisation of surface roughness and energy of contemporary thermoplastic materials used in manufacturing of orthodontic aligners. DESIGN In vitro, laboratory study. MATERIALS AND METHODS Four commercially available thermoplastic materials were selected (CA-medium/CAM, Essix-copopyester/COP, Duran/DUR and Erkodur/ERK). Five disks from each, as received, material were tested and subjected to: (1) reflected light microscopy; (2) optical profilometry for the estimation of Sa, Sz, Sq, Sdr, Sc, Sv surface roughness parameters (n = 5); and (3) contact angle measurements with a Zisman series of liquids for the estimation of critical surface tension (γC), total work of adhesion (WA), as well as the work of adhesion due to polar (WP) and dispersion (WD) components employing the Zisman method (n = 5/liquid). Thermoformed disks were prepared against a dental stone model and the roughness parameters were calculated again Statistical analysis was performed by one-way ANOVA/ Tukey multiple comparison test and t-test (a = 0.05). RESULTS Microscopic and profilometric analyses revealed a smooth surface texture in the as-received materials, but a very rough texture after thermoforming, with insignificant differences within each state. Significant differences in the as-received state were found in the surface energy parameters; CAM showed the lowest γC and the highest WA, WP, WD, whereas ERK with the highest γC demonstrated lower WA. COP and DUR were ranked in an intermediate group regarding γC, with a statistically significant difference in WA between them, mainly attributed to the lower WP of the former. CONCLUSION Given the differences in surface energy parameters and the lack of roughness differences within the as received or thermoformed groups, it may be concluded that variations in the plaque retaining capacity are anticipated, determined by γC, WA and the WP, WD components.
Collapse
Affiliation(s)
- Fabienne Suter
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, ZH, Switzerland
| | - Spiros Zinelis
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, ZH, Switzerland.,Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Attica, Greece
| | - Raphael Patcas
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, ZH, Switzerland
| | - Marc Schätzle
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, ZH, Switzerland
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Attica, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, ZH, Switzerland
| |
Collapse
|
45
|
Hsu KL, Balhaddad AA, Garcia IM, Collares FM, DePaola L, Melo MA. Assessment of surface roughness changes on orthodontic acrylic resins by all-in-one spray disinfectant solutions. J Dent Res Dent Clin Dent Prospects 2020; 14:77-82. [PMID: 32908647 PMCID: PMC7464227 DOI: 10.34172/joddd.2020.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 04/24/2020] [Indexed: 12/25/2022] Open
Abstract
Background. The disinfection of orthodontic acrylic resins might change the physical and mechanical properties of these materials. We aimed to investigate the impact of four different commercially available disinfectants on the surface roughness of acrylic resins used for orthodontic appliances. Methods. Four disinfectant solutions (BirexSE, Opti-Cide3, COEfect MinuteSpray, and CaviCide Spray) were used to disinfect orthodontic acrylic resins using the spraying method. The resins were subjected to repeated disinfection protocols. Distilled water, also applied via spraying method, was used as a control. Surface roughness was scrutinized to examine the extent of surface topography changes by stylus profilometry. Data normality was evaluated via the Shapiro–Wilk test, followed by the Wilcoxon Signed-Rank test for non-parametric data or paired Student’s t-test for parametric data to compare intra-group differences in roughness before and after the use of the disinfectant solutions. Results. Some of the disinfectants (BirexSE and CaviCide) resulted in significant changes in surface roughness values before and after the disinfection compared to the controls (P<0.05). The groups that were in contact with distilled water, Opti-Cide, and Coeffect did not exhibit significant differences in surface roughness before and after the intervention (P>0.05). However, from a clinical perspective, the resulting variations in surface roughness (<%0.15) induced by these solutions might not reflect clinically significant differences. Conclusion. The use of disinfectant solutions is unlikely to harm the surface of orthodontic acrylic resins. Oral care providers need to be attentive to the interpretation and implementation of clinically significant changes in their evidence-based approach regarding potential material damages by disinfection sprays.
Collapse
Affiliation(s)
- Kuei-Ling Hsu
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, MD 21201, USA.,Division of Pediatric Dentistry, Department of Orthodontics and Pediatric Dentistry, University of Maryland School of Dentistry, Baltimore, MD 21201, USA
| | - Abdulrahman A Balhaddad
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, MD 21201, USA.,Department of Restorative Dental Sciences, Imam Abdulrahman Bin Faisal University, College of Dentistry, Dammam, Saudi Arabia
| | - Isadora Martini Garcia
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, MD 21201, USA.,Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, 90035-003, RS, Brazil
| | - Fabrício Mezzomo Collares
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, 90035-003, RS, Brazil
| | - Louis DePaola
- Department of Oncology and Diagnostic Sciences, University of Maryland School of Dentistry, Baltimore, MD 21201, USA
| | - Mary Anne Melo
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, MD 21201, USA.,Division of Operative Dentistry, Department of General Dentistry, University of Maryland School of Dentistry, Baltimore, MD 21201, USA
| |
Collapse
|
46
|
Mechanical Properties of Thermoplastic Polymers for Aligner Manufacturing: In Vitro Study. Dent J (Basel) 2020; 8:dj8020047. [PMID: 32397575 PMCID: PMC7345642 DOI: 10.3390/dj8020047] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/06/2020] [Accepted: 05/07/2020] [Indexed: 12/24/2022] Open
Abstract
The use of metal-free thermoplastic materials plays a key role in the orthodontic digital workflow due to the increasing demand for clear aligner treatments. Three thermoplastic polymers commonly used to fabricate clear aligners, namely Duran®, Biolon® and Zendura®, were investigated to evaluate the effect of thermoforming (T.), storage in artificial saliva (S.A.S.) and their combination on their mechanical properties. Elastic modulus and yield stress of the specimens were characterized. Each material was characterized for each condition through tensile tests (ISO527-1). The results showed that thermoforming does not lead to a significant decrease in yield stress, except for Zendura® that showed about a 30% decrease. An increase of the elastic modulus of Duran® and Zendura®, instead, was observed after thermoforming. The same increase was noticed for the yield stress of Duran®. For S.A.S. specimens, the elastic modulus generally decreases compared to supplier condition (A.S.) and simply thermoformed material. A decrease of yield stress, instead, is significant for Zendura®. The results demonstrated that the impact of the operating conditions on the mechanical properties can vary according to the specific polymer. To design reliable and effective orthodontic treatments, the materials should be selected after their mechanical properties are characterized in the simulated intraoral environment.
Collapse
|
47
|
ATR-FTIR Analysis and One-Week Stress Relaxation of Four Orthodontic Aligner Materials. MATERIALS 2020; 13:ma13081868. [PMID: 32316154 PMCID: PMC7215293 DOI: 10.3390/ma13081868] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 02/06/2023]
Abstract
The aim of this study was to estimate possible differences in the chemical composition and relaxation of orthodontic aligner materials. Four commercially available thermoplastic materials CAM (Scheu-Dental, Iserlohn, Germany), COP (Essix, Dentsply Raintree Essix Sarasota,FL, USA), DUR (Great Lakes Dental Technologies, Tonawanda, NY) and ERK (Erkodent Erich Kopp, Pfalzgrafenweiler Germany) were included in this study. Rectangular strips from each material were prepared according to the manufacturer's instructions and subjected to attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy and stress relaxation characterization. The reduction in applied stress (RAS) after one week was estimated and statistically analyzed by one-way ANOVA at the 0.05 level of significance. All specimens were subjected to optical microscopy before and after stress relaxation testing under transmittance polarized illumination. ATR-FTIR microscopy revealed that all materials are made of polyethylene terephthalate glycol (PETG) while no significant differences were identified in RAS values among materials tested, which ranged from 6%-10% (p ≥ 0.05). All samples illustrated the developments of shear bands during relaxation testing according to optical microscopy findings. The tested materials illustrated similar chemical composition and relaxation behavior and thus no differences in their clinical efficacy are anticipated.
Collapse
|
48
|
Iliadi A, Koletsi D, Papageorgiou SN, Eliades T. Safety Considerations for Thermoplastic-Type Appliances Used as Orthodontic Aligners or Retainers. A Systematic Review and Meta-Analysis of Clinical and In-Vitro Research. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E1843. [PMID: 32295303 PMCID: PMC7215465 DOI: 10.3390/ma13081843] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 04/10/2020] [Accepted: 04/11/2020] [Indexed: 12/19/2022]
Abstract
Use of thermoplastic material in orthodontics, either as aligner or as retainer appliances, is common practice and is likely to increase in the years to come. However, no systematic assessment on safety considerations of these adjuncts has been implemented up to date. The aim of this systematic review was to collectively appraise the existing evidence from both clinical and laboratory studies, on whether these appliances are associated with any estrogenic/cytotoxic effects or bisphenol-A (BPA) and monomer leaching. Eight electronic databases were searched with no limits in December 22, 2019, for published and unpublished research. Eligibility criteria comprised of studies of any design, describing use of any type of thermoplastic aligner. Study selection, data extraction and risk of bias (RoB) assessment was done independently, either in duplicate or confirmed by a second reviewer. Random effects meta-analyses of weighted mean differences (WMD) with associated 95% Confidence Intervals (CIs) were planned. Quality of the evidence was evaluated with Grading of Recommendations Assessment, Development and Evaluation (GRADE). A total of 58 articles were initially identified, while 5 were included in qualitative synthesis and 2 of those contributed to the quantitative syntheses. Four studies were in-vitro, while one was a randomized controlled trial; all assessed some type of orthodontic aligner or retainer, either as-received or retrieved. Risk of bias recordings ranged between unclear and high for all studies. Proliferation induction capacity of thermoplastic appliances' eluents on MCF-7 cells failed to be confirmed compared to beta-estradiol (2 studies: 5% v/v, WMD: -182.08; 95% CI: -198.83, -165.33; p-value < 0.001; and 20% v/v, WMD: -184.53; 95% CI: -206.17, -162.88; p-value < 0.001). No cytotoxic activity was detected as well. In addition, although evidence from in-vitro studies was indicative of no traceable detection of BPA or other monomers, the findings from a single clinical trial were allied to increased levels of BPA in whole stimulated saliva, after up to 30 days of thermoplastic retainer usage, compared to standard Hawley retainer. The quality of the evidence overall was low to medium. Current data from in-vitro research are indicative of an absence of an estrogenic or cytotoxic effect of thermoplastic aligners or retainers. Regarding BPA or monomer release, evidence from clinical and laboratory studies appear inconsistent.
Collapse
Affiliation(s)
- Anna Iliadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece;
| | - Despina Koletsi
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.K.); (S.N.P.)
| | - Spyridon N. Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.K.); (S.N.P.)
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.K.); (S.N.P.)
| |
Collapse
|