1
|
El Hayek JE, Tohme H, Nasr L, El Hachem R, Kabbani N, Mchayleh NF. Fracture strength of preformed zirconia crown and CAD-CAM zirconia, ceramic, and hybrid composite crowns for the restoration of primary molars: An in vitro study. Int J Paediatr Dent 2024; 34:721-728. [PMID: 38403852 DOI: 10.1111/ipd.13171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 12/18/2023] [Accepted: 02/07/2024] [Indexed: 02/27/2024]
Abstract
BACKGROUND Paediatric-preformed zirconia crowns have been associated with several issues, primarily their inability to be crimped and the need for extensive tooth preparation. Additionally, the capacity to adjust the size, shape, and fit of these crowns is very limited. AIM To evaluate and compare the fracture strength of four different types of dental crowns intended for paediatric patients. DESIGN The fracture resistance of four types of paediatric crowns was evaluated using the universal testing machine; freshly extracted primary molars received one of the following: preformed zirconia crowns, custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia crowns, custom-made CAD-CAM ceramic crowns, and custom-made CAD-CAM hybrid composite crowns. Data were statistically compared using the Kruskal-Wallis test followed by the Bonferroni test, and the level of significance was set at 5%. RESULTS Results showed that there was a statistically significant difference among the four groups (p < .001). The highest value of fracture force was observed for the milled zirconia crown and the lowest for the prefabricated zirconia. CONCLUSION The implementation of the CAD-CAM digital crown fabrication technique has the potential to address issues associated with preformed crowns in paediatric patients, particularly in terms of fracture resistance.
Collapse
Affiliation(s)
- Joy Elian El Hayek
- Department of Pediatric Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
- Cranio-Facial Research Laboratory, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
- Department of Digital Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Hani Tohme
- Department of Digital Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Lara Nasr
- Cranio-Facial Research Laboratory, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Roula El Hachem
- Cranio-Facial Research Laboratory, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
- Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Nathalie Kabbani
- Department of Pediatric Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Nada Farhat Mchayleh
- Department of Pediatric Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| |
Collapse
|
2
|
de Carvalho Formiga M, Fuller R, Ardelean LC, Shibli JA. Immediate Loading Full-Arch 3D-Printed Implant-Supported Fixed Rehabilitation: A Case Report with 24-Month Follow-Up. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1614. [PMID: 39459400 PMCID: PMC11509520 DOI: 10.3390/medicina60101614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Revised: 09/29/2024] [Accepted: 09/30/2024] [Indexed: 10/28/2024]
Abstract
Implant-supported immediate loading full-arch rehabilitation has been documented in the literature. More recently, computed surgical guides have frequently been used since they facilitate planning and performing surgical treatment without the need to raise a flap, thus reducing trauma and morbidity. This case report describes an immediate full-arch, fixed rehabilitation with full loading placed on four commercially available 3D-printed implants, with a 24-month follow-up. The implants were placed with the help of a digitally planned 3D-printed surgical guide. The provisional fixed prosthesis installed immediately was replaced after 3 months. At the time, the soft and hard tissue around the implants appeared stable, without signs of inflammation. The same situation was observed at the 24-month follow-up. Three-dimensional-printed implants seem to be a promising choice in this case. However, further clinical studies with longer follow-up periods are necessary to confirm their efficacy.
Collapse
Affiliation(s)
- Márcio de Carvalho Formiga
- Post-Graduation Program in Oral Implantology, University of the Itajaí Valley, Km 207 BR 101, São José 88103-800, SC, Brazil; (M.d.C.F.); (R.F.)
| | - Renato Fuller
- Post-Graduation Program in Oral Implantology, University of the Itajaí Valley, Km 207 BR 101, São José 88103-800, SC, Brazil; (M.d.C.F.); (R.F.)
| | - Lavinia Cosmina Ardelean
- Academic Department of Technology of Materials and Devices in Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq, 300041 Timisoara, Romania
| | - Jamil Awad Shibli
- Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 1 Tereza Cristina Sq., Guarulhos 07023-070, SP, Brazil;
| |
Collapse
|
3
|
Mai HN, Win TT, Kim HS, Pae A, Att W, Nguyen DD, Lee DH. Deep learning and explainable artificial intelligence for investigating dental professionals' satisfaction with CAD software performance. J Prosthodont 2024. [PMID: 39010644 DOI: 10.1111/jopr.13900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 06/06/2024] [Indexed: 07/17/2024] Open
Abstract
PURPOSE This study aimed to examine the satisfaction of dental professionals, including dental students, dentists, and dental technicians, with computer-aided design (CAD) software performance using deep learning (DL) and explainable artificial intelligence (XAI)-based behavioral analysis concepts. MATERIALS AND METHODS This study involved 436 dental professionals with diverse CAD experiences to assess their satisfaction with various dental CAD software programs. Through exploratory factor analysis, latent factors affecting user satisfaction were extracted from the observed variables. A multilayer perceptron artificial neural network (MLP-ANN) model was developed along with permutation feature importance analysis (PFIA) and the Shapley additive explanation (Shapley) method to gain XAI-based insights into individual factors' significance and contributions. RESULTS The MLP-ANN model outperformed a standard logistic linear regression model, demonstrating high accuracy (95%), precision (84%), and recall rates (84%) in capturing complex psychological problems related to human attitudes. PFIA revealed that design adjustability was the most important factor impacting dental CAD software users' satisfaction. XAI analysis highlighted the positive impacts of features supporting the finish line and crown design, while the number of design steps and installation time had negative impacts. Notably, finish-line design-related features and the number of design steps emerged as the most significant factors. CONCLUSIONS This study sheds light on the factors influencing dental professionals' decisions in using and selecting CAD software. This approach can serve as a proof-of-concept for applying DL-XAI-based behavioral analysis in dentistry and medicine, facilitating informed software selection and development.
Collapse
Affiliation(s)
- Hang-Nga Mai
- Institute for Translational Research in Dentistry, Kyungpook National University, Daegu, Republic of Korea
- Hanoi University of Business and Technology, Hanoi, Vietnam
| | - Thaw Thaw Win
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Hyeong-Seob Kim
- Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Ahran Pae
- Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Wael Att
- Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany
- School of Mechanical Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Dang Dinh Nguyen
- Department of Prosthodontics, University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa, USA
| | - Du-Hyeong Lee
- Institute for Translational Research in Dentistry, Kyungpook National University, Daegu, Republic of Korea
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
- The Face Dental Group, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Haugli KH, Alkarra D, Samuelsen JT. Digital manufacturing techniques and the in vitro biocompatibility of acrylic-based occlusal device materials. Clin Oral Investig 2024; 28:312. [PMID: 38748326 PMCID: PMC11096251 DOI: 10.1007/s00784-024-05707-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 05/06/2024] [Indexed: 05/18/2024]
Abstract
OBJECTIVES Material chemistry and workflow variables associated with the fabrication of dental devices may affect the biocompatibility of the dental devices. The purpose of this study was to compare digital and conventional workflow procedures in the manufacturing of acrylic-based occlusal devices by assessing the cytotoxic potential of leakage products. METHODS Specimens were manufactured by 3D printing (stereolithography and digital light processing), milling, and autopolymerization. Print specimens were also subjected to different post-curing methods. To assess biocompatibility, a human tongue epithelial cell line was exposed to material-based extracts. Cell viability was measured by MTT assay while Western blot assessed the expression level of selected cytoprotective proteins. RESULTS Extracts from the Splint 2.0 material printed with DLP technology and post-cured with the Asiga Flash showed the clearest loss of cell viability. The milled and autopolymerized materials also showed a significant reduction in cell viability. However, by storing the autopolymerized material in dH2O for 12 h, no significant viability loss was observed. Increased levels of cytoprotective proteins were seen in cells exposed to extracts from the print materials and the autopolymerized material. Similarly to the effect on viability loss, storing the autopolymerized material in dH2O for 12 h reduced this effect. CONCLUSIONS/CLINICAL RELEVANCE Based on the biocompatibility assessments, clinical outcomes of acrylic-based occlusal device materials may be affected by the choice of manufacturing technique and workflow procedures.
Collapse
Affiliation(s)
- Ketil Hegerstrøm Haugli
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway.
- Dental Technology Program, Faculty of Health Sciences, Oslo Metropolitan University (OsloMet), OsloMet Box 4, St. Olavs plass, Oslo, 0130, Norway.
| | | | | |
Collapse
|
5
|
Todaro C, Cerri M, Rodriguez y Baena R, Lupi SM. Lower Jaw Full-Arch Restoration: A Completely Digital Approach to Immediate Load. Healthcare (Basel) 2024; 12:332. [PMID: 38338217 PMCID: PMC10855469 DOI: 10.3390/healthcare12030332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/08/2024] [Accepted: 01/24/2024] [Indexed: 02/12/2024] Open
Abstract
The digital transformation has revolutionized various sectors, including dentistry. Dentistry has emerged as a pioneer in embracing digital technologies, leading to advancements in surgical and prosthetic oral healthcare. Immediate loading for full-arch edentulous dental implants, once debated, is now widely accepted. This case report describes a 74-year-old patient with dental mobility and significant bone loss who was rehabilitated using a Toronto Bridge protocol on four dental implants with immediate loading. Digital planning, surgical guides, 3D printing, and precision techniques were employed. The surgery involved implant placement and prosthetic procedures. The patient reported minimal post-operative discomfort, and after four months, the definitive prosthesis was successfully placed. This case demonstrates the efficacy of immediate loading in complex dental scenarios with digital innovation, resulting in improved patient outcomes. The full digital workflow, including 3D printing and the use of modern materials, enhances the efficiency and predictability of oral rehabilitation, marking a transformative era in dental care. The integration of digital technology in all phases of treatment, from diagnosis to finalization, makes this approach safer, reliable, and efficient, thereby benefiting both patients and clinicians.
Collapse
Affiliation(s)
- Claudia Todaro
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (R.R.y.B.); (S.M.L.)
| | - Michael Cerri
- Private Practice, 29011 Borgonovo Val Tidone, Italy;
| | - Ruggero Rodriguez y Baena
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (R.R.y.B.); (S.M.L.)
| | - Saturnino Marco Lupi
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (R.R.y.B.); (S.M.L.)
| |
Collapse
|
6
|
Cameron AB, Tong K, Tadakamadla S, Evans JL, Abuzar M. Effect of build orientation on the trueness of occlusal splints fabricated by three-dimensional printing. J Oral Sci 2023; 65:261-264. [PMID: 37690838 DOI: 10.2334/josnusd.23-0115] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/12/2023]
Abstract
PURPOSE Scientific evidence pertaining to the evaluation of trueness of occlusal splints fabricated using different three-dimensional (3D) printers and build orientations compared to subtractive technologies is lacking. METHODS Overall, one hundred and ten occlusal splints were manufactured using two different 3D printers and a dental mill. Five groups of ten were fabricated using the 3D printers at different build orientations (0, 30, 45, 60, and 90 degrees). In addition, a comparison group of ten occlusal splints was subtractively manufactured using a five-axis dental mill. All occlusal splints were scanned and exported as a standard tessellation language file. Analysis was conducted with metrology software with root mean square estimate average positive deviation and average negative deviation used as the measured outcome. RESULTS The 0 degree printing orientation was the most accurate for printer one with the root mean square value of 0.05 ± 0.01 mm, and 60 degree printing orientation was most accurate for printer two with the RMS value of 0.11 ± 0.01 mm. Subtractively manufactured occlusal splint had significantly higher trueness with the lowest RMS value of 0.03 ± 0.05 mm. CONCLUSION Build orientations influence the trueness of additively manufactured occlusal splints while occlusal splints produced by subtractive manufacturing were statistically significantly more accurate.
Collapse
Affiliation(s)
| | - Keith Tong
- School of Medicine and Dentistry, Griffith University
| | - Santosh Tadakamadla
- Dentistry and Oral Health, Department of Rural Clinical Sciences, La Trobe Rural Health School, La Trobe University
- Violet Vines Marshman Centre for Rural Health Research, La Trobe Rural Health School, La Trobe University
| | - Jane L Evans
- School of Medicine and Dentistry, Griffith University
| | - Menaka Abuzar
- School of Medicine and Dentistry, Griffith University
| |
Collapse
|
7
|
Bioengineering Applied to Oral Implantology, a New Protocol: “Digital Guided Surgery”. PROSTHESIS 2023. [DOI: 10.3390/prosthesis5010018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Rehabilitative dentistry has made enormous progress in recent years, not only due to the advent of new implant-prosthetic methods, but also thanks to new information technologies that support the doctor. This study aims to present a new implant protocol that involves the application of bioengineering methods. With the application of the finite element analysis, it is possible to evaluate the distribution of the forces of a fixture and possible implant rehabilitation on each patient, even before performing the surgery. This protocol provides for the combination of radiographic images and three-dimensional files to obtain predictable results on possible rehabilitation, guiding its planning in the best possible way. Surely, the evolution of machines and computers will enable the surgeon to carry out and maintain these protocols in a chair-side manner, and to carry out safe and predictable rehabilitations.
Collapse
|
8
|
Al-Haj Husain A, Stadlinger B, Özcan M, Schönegg D, Winklhofer S, Al-Haj Husain N, Piccirelli M, Valdec S. Buccal bone thickness assessment for immediate anterior dental implant planning: A pilot study comparing cone-beam computed tomography and 3D double-echo steady-state MRI. Clin Implant Dent Relat Res 2023; 25:35-45. [PMID: 36454235 DOI: 10.1111/cid.13160] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 10/16/2022] [Accepted: 10/17/2022] [Indexed: 12/03/2022]
Abstract
PURPOSE To evaluate image quality and diagnostic accuracy of buccal bone thickness assessment in maxillary and mandibular anterior region using cone-beam computed tomography (CBCT) and 3-dimensional double-echo steady-state (DESS) MRI for preoperative planning of immediate dental implants in healthy individuals. METHODS One hundred and twenty teeth in 10 volunteers were retrospectively evaluated for image quality and artifacts using Likert scale (4 = excellent to 0 = decreased). Buccal bone thickness was measured at three measurement points (M1 = 2 mm from the cementoenamel junction, M2 = middle of the root, and M3 = at the root apex) for each tooth in the maxillary (13-23) and the mandibular anterior region (33-43). Descriptive statistics and two-way ANOVA with Tukey's Post-hoc test were performed to evaluate the significant differences (α = 0.05) between both imaging modalities. RESULTS Image quality showed little to no artifacts and enabled confident diagnostic interpretation (CBCT (3.72 ± 0.46); MRI (3.65 ± 0.49)), with no significant differences between both imaging modalities (p > 0.05). Regarding the assessment of buccal bone thickness at M1-M3 for the teeth 13-23 and 33-43, no significant differences were noted (p > 0.05). MRI demonstrated slight, nonsignificant overestimation of thickness with the canines having mainly a thick buccal bone wall, where thin buccal wall was evident for the central incisors. CONCLUSION Black bone MRI sequences, such as 3D-DESS MRI, for immediate implant planning provided confidential diagnostic accuracy in bone thickness assessment without significant disadvantages compared to CBCT. Thus, the implementation of no-dose protocols for dental rehabilitation using an immediate loading approach seems promising and could further improve the treatment strategy for dental rehabilitation.
Collapse
Affiliation(s)
- Adib Al-Haj Husain
- Clinic of Cranio-Maxillofacial and Oral Surgery, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Bernd Stadlinger
- Clinic of Cranio-Maxillofacial and Oral Surgery, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Mutlu Özcan
- Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Daphne Schönegg
- Department of Cranio-Maxillo-Facial and Oral Surgery, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Sebastian Winklhofer
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Nadin Al-Haj Husain
- Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Marco Piccirelli
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Silvio Valdec
- Clinic of Cranio-Maxillofacial and Oral Surgery, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
9
|
Radwan HA, Alsharif AT, Alsharif MT, Aloufi MR, Alshammari BS. Digital technologies in dentistry in Saudi Arabia: Perceptions, practices and challenges. Digit Health 2023; 9:20552076231197095. [PMID: 37662673 PMCID: PMC10469230 DOI: 10.1177/20552076231197095] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 08/08/2023] [Indexed: 09/05/2023] Open
Abstract
Background The aim of this study was to assess practicing dentists' characteristics and professional aspects that influence users to adopt Digital Technologies in Dentistry (DTD) in Saudi Arabia (SA). Moreover, we aimed to identify dentists' perceived barriers and challenges and to anticipate future potential developments towards implementing DTDs in their practices in SA. Methods This analytical cross-sectional study based on a validated questionnaire was conducted using a snowball sampling technique to include a conveniently selected sample of dentists from all dental specialties currently working in SA. Results The response rate was 64% completed and returned. A statistically significantly large share of Gen X (10.1%) used digital technologies (DTs) in dental practice compared with non-digital users. 40% received sufficient postgraduate education on DT, 92% agreed that DT should be included in the undergraduate dental curriculum. However, 79% actually gained skills or knowledge on DT through workshops and formal courses. 'Lack of practitioners' awareness', 'lack of education and pioneers' and 'lack of clinical evidence' were highlighted as the foremost barriers. Lower-frequency DT users believed that treating patients with DT makes treatment more predictable. Together, clinical trials and hands-on training courses can help overcome the barriers to the adoption of new dental technologies. Conclusions Exploring technology adoption and usage amongst practicing dentists allows healthcare stakeholders and policymakers to set a clear direction towards the digitalisation of the healthcare system and within healthcare organisations. The study also highlighted the foremost barriers, challenges and actions towards the adoption of DTDs.
Collapse
Affiliation(s)
- Hawazen A Radwan
- Department of Esthetic and Restorative Dentistry, Prince Sultan Military Hospital Medical City, Riyadh, Saudi Arabia
| | - Alla T Alsharif
- Department of Preventive Dental Science, Taibah University Dental College & Hospital, Almadina, Saudi Arabia
| | - Maha T Alsharif
- Department of Oral Diagnostic Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | | | | |
Collapse
|
10
|
Tallarico M, Lumbau AI, Park CJ, Puddu A, Sanseverino F, Amarena R, Meloni SM. In vitro evaluation of bioburden, three-dimensional stability, and accuracy of surgical templates without metallic sleeves after routinely infection control activities. Clin Implant Dent Relat Res 2021; 23:380-387. [PMID: 33611832 DOI: 10.1111/cid.12986] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 12/28/2020] [Accepted: 01/24/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND Surgical templates are classified as noncritical devices, and they do not need to be sterile. AIM Primary aim of this study was to assess the microbiological burden present on the surgical templates without metallic sleeves after disinfection. Furthermore, to evaluate trueness after disinfection and steam sterilization at 121°C/15 min, and over a 8-week storage period. Finally, to assess their accuracy after in vitro implant placement simulation. MATERIALS AND METHODS Forty surgical templates were printed and divided in five groups of eight templates each. Groups A to C were disinfected with 0.5% Chlorhexidine Gluconate and 70% ethyl alcohol base solution for 15 min. Templates in the group D were steam sterilized at 121°C for 15 min, while, the templates in the group E were used as control. Implant simulation was performed in the group A. Outcome measures were determination of bioburden, trueness assessment using GOM Inspect Professional software, and accuracy evaluated thought the mean angular deviation of simulated implants. RESULTS Total microbic charge measured as colony forming units (CFU) for sample, was 24.40 in the control group (group E; n = 8), and <4.40 in the test group (group C; n = 8), with a reduction of 84%. Colored representation from GOM inspection showed no differences after disinfection and implant simulation, disinfection alone, and steam sterilization, compared to the control group. A very small difference in the surface and volume dimensions was reported 1 month after templates fabrication. The mean roundness tolerances of the tested templates improved of 0.96 ± 0.56° (95% CI 0.57-1.35). CONCLUSION Surgical templates without metallic sleeves can be safely used after disinfection, demonstrating high level of accuracy, even when the surgical procedures should be postponed within a couple of weeks. Further in vivo study are needed to confirm these preliminary results.
Collapse
Affiliation(s)
| | | | - Chang-Joo Park
- Division of Oral and Maxillofacial Surgery, Department of Dentistry, College of Medicine, Hanyang University, Seoul, South Korea
| | - Antonio Puddu
- School of Dentistry, University of Sassari, Sassari, Italy
| | | | | | | |
Collapse
|
11
|
Dental Implant Materials: Current State and Future Perspectives. MATERIALS 2021; 14:ma14020371. [PMID: 33466584 PMCID: PMC7828699 DOI: 10.3390/ma14020371] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 01/12/2021] [Indexed: 12/19/2022]
|
12
|
Pomès B, Behin P, Jordan L, Legoff S, Stoclet G, Richaud E, Nguyen JF. Influence of polymerization pressure and post-cure treatment on conversion degree and viscoelastic properties of polymer infiltrated ceramic network. J Mech Behav Biomed Mater 2020; 115:104286. [PMID: 33383378 DOI: 10.1016/j.jmbbm.2020.104286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/11/2020] [Accepted: 12/13/2020] [Indexed: 12/14/2022]
Abstract
This study aimed at determining an optimum polymerization pressure for Polymer Infiltrated Ceramic Network (PICN) blocks by characterizing the conversion degree (DC) and the viscoelastic properties of experimental PICN blocks polymerized at 90 °C under various high pressures followed or not by post-cure treatment (PC). Near infrared analysis and dynamic mechanical analysis were used to characterize DC and viscoelastic properties of sixteen PICN: one control (thermo-cured) and fifteen experimental groups (one thermo-cured followed by PC and fourteen high pressure polymerized PICN, in the range of 50-350 MPa without and with PC). Conversion degree of high pressure polymerized PICN blocks without post curing displays an optimum between 100 and 150 MPa resulting in an improved E' and Tg. Post curing induces a higher DC with a controversial effect on thermomechanical properties. The results suggested that 100-150 MPa without PC is an optimum polymerization parameter, resulting in PICN blocks with significantly better DC, Tg, E'.
Collapse
Affiliation(s)
- Benjamin Pomès
- UFR d'Odontologie Université de Paris, F-75006, Paris, France; Arts et Métiers ParisTech, Laboratoire de Procédés et Ingénierie en Mécanique et Matériaux (PIMM), CNRS, CNAM, UMR, 8006, F-75013, Paris, France
| | | | - Laurence Jordan
- UFR d'Odontologie Université de Paris, F-75006, Paris, France; PSL Research University, Chimie ParisTech -CNRS, Institut de Recherche de Chimie Paris, F-75005, Paris, France
| | - Stéphane Legoff
- Unité de Recherches Biomatériaux Innovants et Interfaces (URB2I-EA4462), Faculté de Chirurgie Dentaire, Université de Paris, Paris, France
| | - Gregory Stoclet
- Université de Lille, CNRS, INRA, ENSCL, UMR 8207 - UMET - Unité Matériaux et Transformations, F-59000, Lille, France
| | - Emmanuel Richaud
- Arts et Métiers ParisTech, Laboratoire de Procédés et Ingénierie en Mécanique et Matériaux (PIMM), CNRS, CNAM, UMR, 8006, F-75013, Paris, France
| | - Jean-François Nguyen
- UFR d'Odontologie Université de Paris, F-75006, Paris, France; PSL Research University, Chimie ParisTech -CNRS, Institut de Recherche de Chimie Paris, F-75005, Paris, France.
| |
Collapse
|
13
|
Shin JW, Kim JE, Choi YJ, Shin SH, Nam NE, Shim JS, Lee KW. Evaluation of the Color Stability of 3D-Printed Crown and Bridge Materials against Various Sources of Discoloration: An In Vitro Study. MATERIALS 2020; 13:ma13235359. [PMID: 33255922 PMCID: PMC7731151 DOI: 10.3390/ma13235359] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/24/2020] [Accepted: 11/24/2020] [Indexed: 12/28/2022]
Abstract
Recent advances in three-dimensional (3D) printing have introduced new materials that can be utilized for dental restorations. Nonetheless, there are limited studies on the color stability of restorations using 3D-printed crowns and bridge resins. Herein, the color stability of conventional computer-aided design/computer-aided manufacturing (CAD/CAM) blocks and 3D-printing resins was evaluated and assessed for their degrees of discoloration based on material type, colorant types (grape juice, coffee, curry, and distilled water (control group)), and storage duration (2, 7, and 30 days) in the colorants. Water sorption, solubility, and scanning electron microscope (SEM) analyses were conducted. A three-way ANOVA analysis showed that all three factors significantly affected the color change of the materials. Notably, the discoloration (ΔE00) was significantly higher in all 3D printing resins (4.74–22.85 over the 30 days) than in CAD/CAM blocks (0.64–4.12 over the 30 days) following immersion in all colorants. 3D-printing resins showed color differences above the clinical limit (2.25) following storage for 7 days or longer in all experimental groups. Curry was the most prominent colorant, and discoloration increased in almost all groups as the storage duration increased. This study suggests that discoloration must be considered when using 3D printing resins for restorations.
Collapse
Affiliation(s)
- Ji-Won Shin
- Undergraduate Course, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-W.S.); (Y.-J.C.)
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-E.K.); (S.-H.S.); (N.-E.N.); (J.-S.S.)
| | - Young-Jin Choi
- Undergraduate Course, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-W.S.); (Y.-J.C.)
| | - Seung-Ho Shin
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-E.K.); (S.-H.S.); (N.-E.N.); (J.-S.S.)
| | - Na-Eun Nam
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-E.K.); (S.-H.S.); (N.-E.N.); (J.-S.S.)
| | - June-Sung Shim
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-E.K.); (S.-H.S.); (N.-E.N.); (J.-S.S.)
| | - Keun-Woo Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; (J.-E.K.); (S.-H.S.); (N.-E.N.); (J.-S.S.)
- Department of Prosthodontics, Veterans Health Service Medical Center, 53 Jinhwangdo-ro 61-gil, Gangdong-gu, Seoul 05368, Korea
- Correspondence: ; Tel.: +82-2-2228-3157
| |
Collapse
|
14
|
Micovic D, Mayinger F, Bauer S, Roos M, Eichberger M, Stawarczyk B. Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses? Clin Oral Investig 2020; 25:2859-2866. [PMID: 33026523 PMCID: PMC8060225 DOI: 10.1007/s00784-020-03603-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 09/23/2020] [Indexed: 11/29/2022]
Abstract
Objectives To investigate the retention force of polyetheretherketone (PEEK) removable dental prosthesis clasps in comparison with a cobalt-chrome-molybdenum control group after storage in artificial saliva. Materials and Methods Clasps were milled (Dentokeep (PEEKmilled1), NT digital implant technology; breCAM BioHPP Blank (PEEKmilled2), bredent), pressed (BioHPP Granulat for 2 press (PEEKpressed), bredent), or cast (remanium GM 800+ (cobalt-chrome-molybdenum), Dentaurum); N = 60, n = 15/subgroup. Retention force was examined 50 times/specimen in a pull-off test using the universal testing machine (Zwick 1445), where pull-off force was applied with a crosshead speed of 5 mm/minute until the maximum force dropped by 10%, at different aging levels: (1) initial, after storage in artificial saliva for (2) 90 and (3) 180 days. Statistical analysis was performed using one-way ANOVA followed by post hoc Scheffé-test and mixed models (p < 0.05). Results Cobalt-chrome-molybdenum presented the highest retention force. No differences were observed between polyetheretherketone materials. Cobalt-chrome-molybdenum showed a significant decrease of its values after artificial aging, while polyetheretherketone materials presented similar results over the course of aging. Regarding a repetitive insertion and removal, even though PEEKmilled2 and cobalt-chrome-molybdenum showed an initial increase, ultimately, a decrease in retention force was observed for all tested groups. Conclusions Although the control group showed significantly higher results, the retention force of polyetheretherketone materials indicate a potential clinical application. Neither the manufacturing process nor artificial aging showed an impact on the retention force of polyetheretherketone clasps. Clinical relevance Mechanical properties of novel removable dental prosthesis clasp materials devised to meet the growing esthetic demands of patients need to be investigated to ensure a successful long-term clinical application.
Collapse
Affiliation(s)
- Danka Micovic
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Sebastian Bauer
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Malgorzata Roos
- Department of Biostatistics, Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Hirschengraben 84, 8001, Zurich, Switzerland
| | - Marlis Eichberger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
15
|
Feasibility of Using a Prosthetic-Based Impression Template to Improve the Trueness and Precision of a Complete Arch Digital Impression on Four and Six Implants: An In Vitro Study. MATERIALS 2020; 13:ma13163543. [PMID: 32796635 PMCID: PMC7475836 DOI: 10.3390/ma13163543] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 08/03/2020] [Accepted: 08/10/2020] [Indexed: 12/24/2022]
Abstract
Background: Intraoral scanners (IOSs) in implantology represent a viable approach for single teeth or partial arches. However, when used for complete edentulous arches or long-span edentulous areas, it has been demonstrated that there is a need for improvement of IOS-related techniques. Therefore, the aim of this in vitro study was to assess the trueness and precision of a complete arch digital impression on four and six implants taken with or without a customized, prosthetic-based impression template. Materials and Methods: Two experimental models were prepared, representative of a complete edentulous mandible restored with four and six implants with built-in scan abutments. Models were scanned with (test group, TG) or without (control group, CG) the prosthetic-based impression template. Eight scans were taken for each model. The time needed to take impressions, error, trueness, and precision were evaluated. A statistical analysis was performed. Results: In the case of four implants, the time needed for the impression was 128.7 ± 55.3 s in the TG and 81.0 ± 23.5 s in the CG (p = 0.0416). With six scan abutments, the time was 197.5 ± 26.8 and 110.6 ± 25.2 s in the TG and CG, respectively (p = 0.0000). In the TG, no errors were experienced, while in the CG, 13 impressions were retaken due to incorrect stitching processes. In the four-implant impression, the mean angle deviation was 0.252 ± 0.068° (95% CI 0.021–0.115°) in the CG and 0.134 ± 0.053° (95% CI 0.016–0.090°) in the TG. The difference was statistically significant (p = 0.002). In the six-implant impression, the mean angle deviation was 0.373 ± 0.117° (95% CI 0.036–0.198°) in the CG and 0.100 ± 0.029° (95% CI 0.009–0.049°) in the TG (p = 0.000). In the TG, there were no statistically significant differences in the mean angle deviation within the group (p > 0.05), but there were in the CG. A colorimetric analysis showed higher deviations from the original model for the six-implant impression without a prosthetic template. Conclusions: Although all of the impressions exhibited deviation from the original model in the range of clinical acceptability, the prosthetic-based impression template significantly improved the trueness and precision of complete edentulous arches rehabilitated with four or six implants, making the complete arch digital impression more predictable.
Collapse
|