1
|
Nassar HI, Fateen A. Accuracy of fit for cobaltchromium bar over two implants fabricated with different manufacturing techniques: an in-vitro study. BMC Oral Health 2023; 23:946. [PMID: 38031111 PMCID: PMC10688085 DOI: 10.1186/s12903-023-03700-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Accepted: 11/22/2023] [Indexed: 12/01/2023] Open
Abstract
OBJECTIVE The purpose of the invitro research was to compare the fit of Cobalt Chromium customized bar fabricated with different manufacturing processes cast metal bar, milled bar and 3D printed bar using scanning electron microscope. MATERIALS AND METHODS Clear epoxy resin molds were prepared. In each mold two parallel implants with a 14 mm distance from each other were embedded. Thirty Co-Cr custom bars were constructed and were divided equally into three groups: Group (I) (Co-Cr conv), group (II) milled bar (Co-Cr milled), and group (III) printed bar (Co-Cr print). The marginal fit at implant-abutment interface was scanned using scanning electron microscope (SEM). RESULTS There was a significant difference between the three studied groups regarding marginal misfit the between implant and fabricated bars with p-value < 0.001. The highest value of micro-gap distance was found in Co-Cr conventional group (7.95 ± 2.21 μm) followed by Co-Cr 3D printed group (4.98 ± 1.73) and the lower value were found in Co-Cr milled (3.22 ± 0.75). CONCLUSION The marginal fit of milled, 3D printed and conventional cast for Co-Cr alloy were within the clinically acceptable range of misfit. CAD/CAM milled Co-Cr bar revealed a superior internal fit at the implant-abutment interface. This was followed by selective laser melting (SLM) 3D printed bar and the least fit was shown for customized bar with the conventional lost wax technique.
Collapse
Affiliation(s)
- Hossam I Nassar
- Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt.
| | - Ayman Fateen
- Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| |
Collapse
|
2
|
Molinero-Mourelle P, Peter L, Gaviria AS, Fonseca M, Schimmel M, Katsoulis J. Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study. Acta Odontol Scand 2023; 81:591-596. [PMID: 37319413 DOI: 10.1080/00016357.2023.2223715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/05/2023] [Accepted: 06/06/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. METHODS Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values <5% were considered statistically significant. RESULTS The tactile assessment showed a mean total sensitivity for the Straumann and Nobel Biocare systems of 83% and 80% with a used probe, and 91% and 92% with a new probe, respectively. The mean total specificities were 33% and 20% with a used probe and 17% and 3% with a new probe, respectively. No statistical significance was observed between novice and expert clinicians concerning their tactile assessment ability. CONCLUSIONS The ability to detect a perfect fit (specificity) with a probe was very poor for both implant systems and impaired with the use of a new probe. The use of a new probe improved the gap detection ability (sensitivity) significantly at the expense of the specificity. A combination of additional chairside techniques with training and calibration could improve clinicians' ability to correctly assess the fit/misfit at the implant-abutment interface.
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Conservative Dentistry and Orofacial Prosthodontics, Complutense University of Madrid, Madrid, Spain
| | - Lukas Peter
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ana Sol Gaviria
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Joannis Katsoulis
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Preventive and Restorative Sciences, Robert Schattner Center, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
3
|
Cascos R, Celemín-Viñuela A, Mory-Rubiños N, Gómez-Polo C, Ortega R, Agustín-Panadero R, Gómez-Polo M. Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6532. [PMID: 37834669 PMCID: PMC10573618 DOI: 10.3390/ma16196532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/22/2023] [Accepted: 09/28/2023] [Indexed: 10/15/2023]
Abstract
This in vitro study aimed to assess the presence of microgaps at the implant-abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. METHODS Sixty conical connection dental implants were divided into two groups (n = 30). The control group consisted of three-unit bridge monolithic zirconia connected to two implants by a transepithelial abutment. The test group consisted of monolithic zirconia three-unit restoration connected to two implants directly by a titanium base (Ti-base) abutment. The sample was subjected to thermocycling (10,000 cycles at 5 °C to 55 °C, dwelling time 50 s) and chewing simulation (300,000 cycles, under 200 N at frequencies of 2 Hz, at a 30° angle). The microgap was evaluated at six points (mesiobuccal, buccal, distobuccal, mesiolingual, lingual, and distolingual) of each implant-abutment interface by using a scanning electron microscope (SEM). The data were analyzed using the Mann-Whitney U tests (p > 0.05). RESULTS The SEM analysis showed a smaller microgap at the implant-abutment interface in the control group (0.270 μm) than in the test group (3.902 μm). Statistically significant differences were observed between both groups (p < 0.05). CONCLUSIONS The use or not of transepithelial abutments affects the microgap size. The transepithelial abutments group presented lower microgap values at the interface with the implant than the Ti-base group in monolithic zirconia partial implant-supported fixed prostheses. However, both groups had microgap values within the clinically acceptable range.
Collapse
Affiliation(s)
- Rocío Cascos
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain;
| | - Alicia Celemín-Viñuela
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| | - Nataly Mory-Rubiños
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| | - Cristina Gómez-Polo
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain;
| | - Rocío Ortega
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain;
| | - Rubén Agustín-Panadero
- Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain;
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (A.C.-V.); (N.M.-R.); (M.G.-P.)
| |
Collapse
|
4
|
Olander J, Barkarmo S, Hammarström Johansson P, Wennerberg A, Stenport VF. Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients. J Oral Maxillofac Res 2023; 14:e2. [PMID: 37969950 PMCID: PMC10645473 DOI: 10.5037/jomr.2023.14302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 09/27/2023] [Indexed: 11/17/2023]
Abstract
Objectives The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads. Material and Methods Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads. Results In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group. Conclusions Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.
Collapse
Affiliation(s)
- Julia Olander
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Sargon Barkarmo
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Petra Hammarström Johansson
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Ann Wennerberg
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Victoria Franke Stenport
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| |
Collapse
|
5
|
Kowalski J, Puszkarz AK, Radwanski M, Sokolowski J, Cichomski M, Bourgi R, Hardan L, Sauro S, Lukomska-Szymanska M. Micro-CT Evaluation of Microgaps at Implant-Abutment Connection. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4491. [PMID: 37374674 DOI: 10.3390/ma16124491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/10/2023] [Accepted: 06/17/2023] [Indexed: 06/29/2023]
Abstract
The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 µm for Astra and from 0.1 to 4.9 µm for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.
Collapse
Affiliation(s)
- Jakub Kowalski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | - Adam K Puszkarz
- Faculty of Material Technologies and Textile Design, Institute of Material Science of Textiles and Polymer Composites, Lodz University of Technology, 116 Zeromskiego Street, 90-924 Lodz, Poland
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 92-213 Lodz, Poland
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | - Michal Cichomski
- Department of Material Technology and Chemistry, Faculty of Chemistry, University of Lodz, Pomorska 163, 90-236 Lodz, Poland
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Salvatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Cienciasde la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115 Valencia, Spain
- Department of Therapeutic Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia
| | | |
Collapse
|
6
|
Simionato AA, Santos EDS, Faria ACL, do Nascimento C, Rodrigues RCS, Ribeiro RF. Bacterial Detection, Deformation, and Torque Loss on Dental Implants with Different Tapered Connections Compared with External Hexagon Connection after Thermomechanical Cycling. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16113904. [PMID: 37297037 DOI: 10.3390/ma16113904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 05/19/2023] [Accepted: 05/21/2023] [Indexed: 06/12/2023]
Abstract
The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant. Test (n = 10) and control (n = 3) groups were set up. Evaluations were made on torque loss, Scanning Electron Microscopy (SEM), and Micro Computerized Tomography (MicroCT) after performing 2 × 106 mechanical cycles (120 N) and 600 thermal cycles (5°-55° C) with 2 mm lateral displacement. The contents of the IAI were collected for microbiological analysis. There was a difference (p < 0.05) in torque loss of the groups tested; groups from the 16° IAI obtained a lower percentage of torque loss. All groups presented contamination and the analysis of the results shows that the microbiological profile of the IAI differs qualitatively from the profile found in the saliva used for contamination. The mechanical loading affects the microbiological profile found in the IAIs (p < 0.05). In conclusion, the IAI environment may favor a microbiological profile different from that of saliva and the thermocycling condition may alter the microbial profile found in the IAI.
Collapse
Affiliation(s)
- Anselmo Agostinho Simionato
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-904, Brazil
| | - Emerson de Souza Santos
- Department of Clinical Analysis, Toxicology, and Food Science, School of Pharmaceutical Sciences of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-903, Brazil
| | - Adriana Cláudia Lapria Faria
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-904, Brazil
| | - Cássio do Nascimento
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-904, Brazil
| | - Renata Cristina Silveira Rodrigues
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-904, Brazil
| | - Ricardo Faria Ribeiro
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of São Paulo, Ribeirao Preto 14040-904, Brazil
| |
Collapse
|
7
|
Wakamori K, Nagata K, Nakashizu T, Tsuruoka H, Atsumi M, Kawana H. Comparative Verification of the Accuracy of Implant Models Made of PLA, Resin, and Silicone. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093307. [PMID: 37176189 PMCID: PMC10179293 DOI: 10.3390/ma16093307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/19/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023]
Abstract
Polylactic acid (PLA) has gained considerable attention as an alternative to petroleum-based materials due to environmental concerns. We fabricated implant models with fused filament fabrication (FFF) 3D printers using PLA, and the accuracies of these PLA models were compared with those of plaster models made from silicone impressions and resin models made with digital light processing (DLP). A base model was obtained from an impact-training model. The scan body was mounted on the plaster, resin, and PLA models obtained from the base model, and the obtained information was converted to stereolithography (STL) data by the 3D scanner. The base model was then used as a reference, and its data were superimposed onto the STL data of each model using Geomagic control. The horizontal and vertical accuracies of PLA models, as calculated using the Tukey-Kramer method, were 97.2 ± 48.4 and 115.5 ± 15.1 μm, respectively, which suggests that the PLA model is the least accurate among the three models. In both cases, significant differences were found between PLA and gypsum and between the PLA and resin models. However, considering that the misfit of screw-retained implant frames should be ≤150 µm, PLA can be effectively used for fabricating implant models.
Collapse
Affiliation(s)
- Kana Wakamori
- Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| | - Koudai Nagata
- Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| | - Toshifumi Nakashizu
- Division of the Dental Practice Support, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| | - Hayato Tsuruoka
- Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| | - Mihoko Atsumi
- Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| | - Hiromasa Kawana
- Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan
| |
Collapse
|
8
|
Gehrke SA, Scarano A, Cortellari GC, Fernandes GVO, Mesquita AMM, Bianchini MA. Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study. J Funct Biomater 2023; 14:jfb14030128. [PMID: 36976052 PMCID: PMC10057670 DOI: 10.3390/jfb14030128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/20/2023] [Accepted: 02/23/2023] [Indexed: 03/03/2023] Open
Abstract
The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12–18 months, 34 between 19–24 months, and 44 between 25–33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was −0.67 ± 0.65 mm in mesial and −0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments’ diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, −0.57 ± 0.53 mm (mesial) and −0.66 ± 0.50 mm (distal), and −0.78 ± 0.75 mm (mesial) and −0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.
Collapse
Affiliation(s)
- Sergio Alexandre Gehrke
- Department of Research, Bioface/PgO/UCAM, Calle Cuareim 1483, Montevideo 11100, Uruguay
- Instituto de Bioingenieria, Universidad Miguel Hernández, Avda. Ferrocarril s/n., 03202 Elche, Spain
- Department of Biotechnology, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain
- Department of Materials Engineering, Pontificia Universidade Católica do Rio Grande do Sul, Porto Alegre 90619-900, Brazil
- Correspondence: (S.A.G.); (G.V.O.F.); Tel./Fax: +598-29015634 (S.A.G.)
| | - Antonio Scarano
- Department of Research, Bioface/PgO/UCAM, Calle Cuareim 1483, Montevideo 11100, Uruguay
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy
| | | | - Gustavo Vicentis Oliveira Fernandes
- Periodontics and Oral Medicine Department, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA
- Correspondence: (S.A.G.); (G.V.O.F.); Tel./Fax: +598-29015634 (S.A.G.)
| | | | - Marco Aurélio Bianchini
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis 88040-900, Brazil
| |
Collapse
|
9
|
Campos MRD, Oliveira TTD, Botelho AL, Reis ACD. Mechanical, Chemical, and Biological Properties of 3D-Printed Abutments: A Systematic Review. JOURNAL OF ADVANCED ORAL RESEARCH 2022. [DOI: 10.1177/23202068221099772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aim: A systematic review of the methods of 3D printing and the materials used so far for the manufacture of abutments was performed to evaluate whether their clinical use is indicated through the mechanical, chemical, and biological analyses carried out. Materials and Methods: An electronic search conducted by three independent reviewers was carried out in the PubMed, Web of Science, Cochrane Library, Science Direct, and Lilac databases. The inclusion criterion was researching articles in English that contained as subject the manufacturing of abutments through 3D printing/additive manufacturing. Any meta-analyses, reviews, book chapters, abstracts, letters, conferences papers, and studies without abutments printed were excluded. Results: We found 780 references, which after applying the exclusion criteria resulted in the final inclusion of seven articles for review. The studies had a high heterogeneity, showing different materials and methodologies to manufacture abutments, which makes a comparison between them difficult, and for this reason it was not possible to carry out a meta-analysis with the data found. Conclusions: Even with the limitations found in the present research, it is possible to conclude that printed abutments have adequate mechanical, chemical, and biological properties that can indicate their clinical use. 3D printing presents high accuracy and speed and can produce customized abutments according to each case.
Collapse
Affiliation(s)
- Murilo Rodrigues de Campos
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| | | | - André Luís Botelho
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| | - Andréa Cândido dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| |
Collapse
|
10
|
Fathi A, Rismanchian M, Dezaki SN. Effectiveness of Different Antimicrobial Agents on Malodor Prevention in Two-Stage Dental Implants: A Double-Blinded Randomized Clinical Trial. Eur J Dent 2022. [PMID: 35820442 DOI: 10.1055/s-0042-1747954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVE Opening of a healing abutment in two-stage implant systems is usually followed by a bad smell. Previous studies have found that presence of bacteria in microleakages of the implant-abutment interface results in further malodor. However, studies focusing on preventive treatments for this issue are scarce. Therefore, the aim of this study is to evaluate the effectiveness of two antimicrobial agents on prevention of malodor followed by opening the healing abutments. MATERIALS AND METHODS Current double-blinded randomized clinical trial was performed on 51 eligible patients who were referred for their exposure surgery. They were divided equally into three parallel groups. In two groups, either chlorhexidine or tetracycline was added to the internal surface of the fixtures before screwing the healing abutments. One group did not receive any intervention. Three to 4 weeks later malodor was scored by sniffing the healing abutments immediately after uncovering them (odorless = 0/odor = 1). The three groups were then compared regarding malodor scores. RESULTS Our findings showed that malodor was more frequent in the control group (58.82%) in comparison with groups of intervention (17.65 and 23.53%). There was a statistically significant difference between malodor in patients in whom antimicrobial agents (chlorhexidine and tetracycline) were used in their implants and the control group (p-value = 0.023). However, malodor in the chlorhexidine group and tetracycline group did not show any significant difference (p-value = 1). CONCLUSION Based upon the data from this study, it appears that local antimicrobial agents including chlorhexidine and tetracycline result in less malodor production within the implant-abutment interface. CLINICAL SIGNIFICANCE A specific type of malodor is commonly seen after opening the healing abutment of a two-stage dental implant. Not only this issue is noticed by the dentist, but also annoyed the patient. Using local antimicrobial agents in the fixtures is likely to be a simple, easily applicable solution that satisfies both patients and dentists, and eliminates the possibility of further inflammation.
Collapse
Affiliation(s)
- Amirhossein Fathi
- Dental Materials Research Center, Dental Prosthodontics Department, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mansour Rismanchian
- Dental Implants Research Center, Dental Prosthodontics Department, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Sara Nasrollahi Dezaki
- Dental Students Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
11
|
Molinero-Mourelle P, Roccuzzo A, Yilmaz B, Lam WYH, Pow EHN, Del Río Highsmith J, Gómez-Polo M. Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study. Clin Oral Implants Res 2022; 33:945-952. [PMID: 35818785 PMCID: PMC9544167 DOI: 10.1111/clr.13973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 06/19/2022] [Accepted: 06/22/2022] [Indexed: 11/28/2022]
Abstract
Objective To assess the marginal and bacterial microleakage in zirconia and CAD‐CAM or cast Co‐Cr implant abutments. Methods Sixty‐four conical connection implants with their respective abutments were divided into four groups (Co‐Cr (milled, laser‐sintered, and cast) and Zirconia (milled)). All specimens were subjected to a chewing simulation and thermocycling. After aging process, specimens were submerged in a 0.2% methylene blue solution with Porphyromonas gingivalis (P.g) for 48 h. The marginal microleakage was measured using a 40× optical microscopy at the internal part of the implant, and when positive microleakage was observed, a DNA isolation with a polymerase chain reaction (PCR) test was used. The microbiological assessment was based on colony forming units (CFUs). Results Thirty (47%) implant‐abutments presented microleakage and the PCR was performed on those specimens (1 Zirconia, 1 Co‐Cr milled, 14 Co‐Cr laser‐sintered and 14 cast). Seven specimens (1 Co‐Cr laser‐sintered and six cast) presented values below the PCR detection limit (< 100 CFUs). The lowest CFUs count occurred in the Co‐Cr milled group (5.17E+02 CFUs/ml) followed by zirconia (7.70E+03 CFUs/ml). The Co‐Cr cast (9.39E+03 CFUs/ml) and laser‐sintered (2.4E+05 CFUs/ml) groups had higher bacterial count. The CFU count comparison performed between Co‐Cr cast and laser‐sintered resulted in a statistically significant differences in favor of Co‐CrCL (p < .05). Conclusions The abutment material and fabrication technique affected the implant‐abutment microleakage. Although the CAD‐CAM abutments presented favorable results, all tested groups presented microleakage.
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Conservative Dentistry and Orofacial Prosthetics. Faculty of Dentistry, Complutense University of Madrid.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Andrea Roccuzzo
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Oral and Maxillofacial Surgery, Copenhagen University Hospital (Rigshospitalet), Copenhagen, Denmark
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland.,Department of Preventive, and Pediatric Dentistry, School of Dental Medicine, University of Bern, Switzerland
| | - Walter Yu Hang Lam
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Edmond H N Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Jaime Del Río Highsmith
- Department of Conservative Dentistry and Orofacial Prosthetics. Faculty of Dentistry, Complutense University of Madrid
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthetics. Faculty of Dentistry, Complutense University of Madrid
| |
Collapse
|
12
|
Barenghi L, Barenghi A, Garagiola U, Di Blasio A, Giannì AB, Spadari F. Pros and Cons of CAD/CAM Technology for Infection Prevention in Dental Settings during COVID-19 Outbreak. SENSORS (BASEL, SWITZERLAND) 2021; 22:49. [PMID: 35009586 PMCID: PMC8747329 DOI: 10.3390/s22010049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/13/2021] [Accepted: 12/15/2021] [Indexed: 12/12/2022]
Abstract
The purpose of this commentary is to update the evidence reported in our previous review on the advantages and limitations of computer-aided design/computer-aided manufacturing technology in the promotion of dental business, as well as to guarantee patient and occupational safety. The COVID-19 pandemic led to an unprecedented focus on infection prevention; however, waves of COVID-19 follow one another, asymptomatic cases are nearly impossible to identify by triage in a dental setting, and the effectiveness of long-lasting immune protection through vaccination remains largely unknown. Different national laws and international guidelines (mainly USA-CDC, ECDC) have often brought about dissimilar awareness and operational choices, and in general, there has been very limited attention to this technology. Here, we discuss its advantages and limitations in light of: (a) presence of SARS-CoV-2 in the oral cavity, saliva, and dental biofilm and activation of dormant microbial infections; (b) the prevention of SARS-CoV-2 transmission by aerosol and fomite contamination; (c) the detection of various oral manifestations of COVID-19; (d) specific information for the reprocessing of the scanner tip and the ward from the manufacturers.
Collapse
Affiliation(s)
- Livia Barenghi
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Alberto Barenghi
- Department of Medicine and Surgery, Centro di Odontoiatria, Parma University, 43126 Parma, Italy; (A.B.); (A.D.B.)
| | - Umberto Garagiola
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Alberto Di Blasio
- Department of Medicine and Surgery, Centro di Odontoiatria, Parma University, 43126 Parma, Italy; (A.B.); (A.D.B.)
| | - Aldo Bruno Giannì
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| | - Francesco Spadari
- Department of Biomedical, Surgical and Dental Sciences, University of Milano, 20122 Milan, Italy; (U.G.); (A.B.G.); (F.S.)
| |
Collapse
|
13
|
Galindo-Moreno P, Concha-Jeronimo A, Lopez-Chaichio L, Rodriguez-Alvarez R, Sanchez-Fernandez E, Padial-Molina M. Marginal Bone Loss around Implants with Internal Hexagonal and Internal Conical Connections: A 12-Month Randomized Pilot Study. J Clin Med 2021; 10:jcm10225427. [PMID: 34830709 PMCID: PMC8621760 DOI: 10.3390/jcm10225427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/12/2021] [Accepted: 11/18/2021] [Indexed: 02/07/2023] Open
Abstract
The aim of this study was to analyze the differences in terms of the marginal bone level (MBL) around implants with either an internal conical or an internal hexagonal implant–prosthesis connection. A randomized clinical trial included patients in need of a single implant-supported restoration. The implant–prosthesis connection was either internal conical or internal hexagonal while maintaining the same type of implant macro- and microarchitecture. Clinical and radiographical variables were registered up to 12 months of follow-up, including MBL. A total of 30 patients were included in the study. The main outcome variable, MBL 12 months after prosthesis delivery, was statistically different in both groups: −0.25 (0.12) vs. −0.70 (0.43) (conical vs. hexagonal; p = 0.033). Differences were also observed at the 3- and 6-month follow-up visits as well as for the MBL change from prosthesis delivery to the 12-month follow-up (−0.15 (0.13) vs. −0.56 (0.44); conical vs. hexagonal; p = 0.023). Correlations between MBL around the implants and radiographic measurements on the adjacent teeth, buccal bone to implant, tissue thickness or keratinized tissue were not significant neither globally nor when analyzed independently by group. In view of such results, it can be concluded that single-unit restorations with internal hexagonal-connection implants induce higher marginal bone loss after 12 months of follow-up from prosthesis delivery than internal conical-connection implants.
Collapse
Affiliation(s)
- Pablo Galindo-Moreno
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- Correspondence:
| | - Ada Concha-Jeronimo
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Lucia Lopez-Chaichio
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Roque Rodriguez-Alvarez
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Elena Sanchez-Fernandez
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
| | - Miguel Padial-Molina
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| |
Collapse
|
14
|
Abstract
Implant supported dental prostheses are increasingly used in dental practice. The aim of this narrative review is to present the influence of transmucosal surface of prosthetic abutment and implant on peri-implant tissue. The article describes causes of bone loss around the dental implant. Moreover, properties of different materials are compared and discussed. The advantages, disadvantages, and biomechanical concept of different implant-abutment connections are presented. The location of connections in relation to the bone level and the influence of microgap between the abutment and implant are described. Additionally, the implant abutments for cemented and screwed prosthetic restorations are compared. The influence of implant and abutment surface at the transmucosal level on peri-implant soft tissue is discussed. Finally, the biological aspect of abutment-implant connection is analyzed.
Collapse
|