Carbonaro D, Villa E, Gallo D, Morbiducci U, Audenino AL, Chiastra C. Designing the mechanical behavior of NiTi self-expandable vascular stents by tuning the heat treatment parameters. J Mech Behav Biomed Mater 2024; 158:106653. [PMID: 39074439 DOI: 10.1016/j.jmbbm.2024.106653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/14/2024] [Accepted: 07/06/2024] [Indexed: 07/31/2024]
Abstract
The remarkable mechanical properties of nickel-titanium (NiTi) shape memory alloy, particularly its super-elasticity, establish it as the material of choice for fabricating self-expanding vascular stents, including the metallic backbone of peripheral stents and the metallic frame of stent-grafts. The super-elastic nature of NiTi substantially influences the mechanical performance of vascular stents, thereby affecting their clinical effectiveness and safety. This property shows marked sensitivity to the primary parameters of the heat treatment process used in device fabrication, specifically temperature and processing time. In this context, this study integrates experimental and computational analyses to explore the potential of designing the mechanical characteristics of NiTi vascular stents by adjusting heat treatment parameters. To reach this aim, differently heat-treated NiTi wire samples were experimentally characterized using calorimetric and uniaxial tensile testing. Subsequently, the mechanical response of a stent-graft model featuring a metallic frame made of NiTi wire was assessed in terms of radial forces generated at various implantation diameters through finite element analysis. The stent-graft served as an illustrative case of NiTi vascular stent to investigate the impact of the heat treatment parameters on its mechanical response. From the study a strong linear relationship emerged between NiTi super-elastic parameters (i.e., austenite finish temperature, martensite elastic modulus, upper plateau stress, lower plateau stress and transformation strain) and heat treatment parameters (R2 > 0.79, p-value < 0.001) for the adopted ranges of temperature and processing time. Additionally, a strong linear relationship was observed between: (i) the radial force generated by the stent-graft during expansion and the heat treatment parameters (R2 > 0.82, p-value < 0.001); (ii) the radial force generated by the stent-graft during expansion and the lower plateau stress of NiTi (R2 > 0.93, p-value < 0.001). In conclusion, the findings of this study suggest that designing and optimizing the mechanical properties of NiTi vascular stents by finely tuning temperature and processing time of the heat treatment process is feasible.
Collapse
Affiliation(s)
- Dario Carbonaro
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Elena Villa
- National Research Council, Institute of Condensed Matter Chemistry and Technologies for Energy (CNR-ICMATE), Lecco, Italy
| | - Diego Gallo
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Umberto Morbiducci
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Alberto Luigi Audenino
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| | - Claudio Chiastra
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
2
|
Seo BG, Lee IW, Kim HJ, Lee YJ, Kim O, Lee JH, Lee JH, Hwangbo C. Angiogenic properties and intercellular communication of differentiated porcine endothelial cells in vascular therapy. Sci Rep 2024; 14:22844. [PMID: 39354086 DOI: 10.1038/s41598-024-73584-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Accepted: 09/18/2024] [Indexed: 10/03/2024] Open
Abstract
Endothelial cell dysfunction can lead to various vascular diseases. Blood flow disorder is a common symptom of vascular diseases. Regenerative angiogenesis, which involves transplanting vascular cells or stem cells into the body to shape new vasculature, can be a good therapeutic strategy. However, there are several limitations to using autologous cells from the patients themselves. We sought to investigate the new vascular cells that can play a role in the formation of angiogenesis in vivo using stem cells from alternative animals suitable for cellular therapy. Porcine is an optimal animal model for xenotransplantation owing to its physiological similarity to humans. We used differentiated porcine endothelial cells (pECs) as a therapeutic strategy to restore vessel function. Differentiated pECs formed vessel-like structures in mice, distinguishing them from stem cells. MMPs activity and migration assays indicated that differentiated pECs possessed angiogenic potential. Tube formation and 3D spheroid sprouting assays further confirmed the angiogenic phenotype of the differentiated pECs. Immunofluorescence and immunoprecipitation analyses revealed claudin-mediated tight junctions and connexin 43-mediated gap junctions between human ECs and differentiated pECs. Additionally, the movement of small RNA from human ECs to differentiated pECs was observed under co-culture conditions. Our findings demonstrated the in vivo viability and angiogenetic potential of differentiated pECs and highlighted the potential for intercellular communication between human and porcine ECs. These results suggest that transplanted cells in vascular regeneration completed after cell therapy have the potential to achieve intercellular communication within the body.
Collapse
Affiliation(s)
- Bo-Gyeong Seo
- Division of Life Science, College of Natural Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
- Division of Applied Life Science (BK21 Four), Research Institute of Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
| | - In-Won Lee
- Division of Applied Life Science (BK21 Four), Research Institute of Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
- Department of Animal Bioscience, College of Agriculture & Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
| | - Hyo-Jin Kim
- Division of Life Science, College of Natural Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
- Division of Applied Life Science (BK21 Four), Research Institute of Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
| | - Yeon-Ji Lee
- Division of Applied Life Science (BK21 Four), Research Institute of Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
- Department of Animal Bioscience, College of Agriculture & Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea
| | - Okhwa Kim
- Kangwon Institute of Inclusive Technology, Kangwon National University, Chuncheon, Gangwon-do, 24341, Republic of Korea
| | - Joon-Hee Lee
- Department of Animal Bioscience, College of Agriculture & Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea.
- Institute of Agriculture and Life Science, College of Agriculture & Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea.
| | - Jeong-Hyung Lee
- Kangwon Institute of Inclusive Technology, Kangwon National University, Chuncheon, Gangwon-do, 24341, Republic of Korea.
- Department of Biochemistry (BK21 Four), College of Natural Sciences, Kangwon National University, Chuncheon, Gangwon-do, 24341, Republic of Korea.
| | - Cheol Hwangbo
- Division of Life Science, College of Natural Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea.
- Division of Applied Life Science (BK21 Four), Research Institute of Life Sciences, Gyeongsang National University, Jinju, 52828, Republic of Korea.
| |
Collapse
|
3
|
Teong YW, Mustapha KB, Ibitoye MO. Finite element analysis and surrogate-optimized design of a nature-inspired auxetic stent. Comput Methods Biomech Biomed Engin 2024:1-17. [PMID: 39256915 DOI: 10.1080/10255842.2024.2399018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 02/06/2024] [Accepted: 08/21/2024] [Indexed: 09/12/2024]
Abstract
Prior studies have revealed that the structural design of stents is critical to reducing some of the alarming post-operative complications associated with stent-related intervention. However, the technical search for stents that guarantee robustness against stent-induced post-intervention complications remains an open problem. Along this objective, this study investigates a re-entrant auxetic stent's structural response and performance optimizations. In pursuit of the goal, a nonlinear finite element analysis (FEA) is employed to uncover metrics characterizing the auxetic stent's mechanical behavior. Subsequently, the non-dominated sorting genetic algorithm (NSGA-II) is implemented to simultaneously minimize the stent's von Mises stress and the elastic radial recoil (ERR). Results from the FEA revealed a tight connection between the stent's response and the features of the base auxetic building block (the rib length, strut width, and the re-entrant angle). It is observed that the auxetic stent exhibits a much lower ERR. Besides, larger values of its rib length and re-entrant angle are noticed to favor smaller von Mises stress. The Pareto-optimal front from the NSGA-II-based optimization scheme revealed a sharp trade-off in the simultaneous minimization of the von Mises stress and the ERR. Moreover, an optimal combination of the auxetic unit cell's geometric parameters is found to yield a much lower maximum von Mises stress of ≈ 403 MPa and ERR of ≈ 0.4 % .
Collapse
Affiliation(s)
- Y W Teong
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham (Malaysia Campus), Semenyih, Malaysia
| | - K B Mustapha
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham (Malaysia Campus), Semenyih, Malaysia
| | | |
Collapse
|
4
|
Phan T, Jones JE, Liao Y, Yu Q, Chen M. The Mechanical and Electrochemical Stability of Trimethysilane Plasma Nanocoatings Deposited onto Cobalt Chromium Cardiovascular Stents. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3699. [PMID: 39124362 PMCID: PMC11312952 DOI: 10.3390/ma17153699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/20/2024] [Accepted: 07/23/2024] [Indexed: 08/12/2024]
Abstract
The objective of this study was to evaluate the coating integrity performance and corrosion protection property of trimethylsilane (TMS) plasma nanocoatings that were directly deposited onto cobalt chromium (CoCr) L605 cardiovascular stents. Hydrophilic surfaces were achieved for the TMS plasma nanocoatings that were deposited onto the coronary stents through NH3/O2 (2:1 molar ratio) plasma post-treatment. With a coating thickness of approximately 20-25 nm, the TMS plasma nanocoatings were highly durable and able to resist delamination and cracking from crimping and expansion by a Model CX with a J-Crimp Station. The stent surface that was evaluated by Scanning Electron Microscopy (SEM) and Energy-Dispersive X-ray Spectroscopy (EDS) showed no indications of pitting, corrosion, or adsorption products on either the luminal or abluminal surfaces of the stents, in contrast to the uncoated stent surface. The TMS plasma nanocoatings significantly enhanced the stent's corrosion resistance in immersion experiments that followed the ASTM F2129-15 corrosion protocol, evident in the increase of the open circuit potential (OCP) from 0.01 V for the uncoated L605 stent to 0.18 V for the plasma-nanocoated L605 stent, reducing potential cytotoxic metal ion release. Cyclic polarization (CP) curves show that the corrosion rate (density level) observed in plasma-nanocoated L605 stents was approximately half an order of magnitude lower than that of the uncoated stents, indicating improved corrosion protection of the stents. CP curves of the TMS plasma-nanocoated stents with different coating thicknesses show that, in the range of 20-65 nm, the coating thickness does not result in any difference in the corrosion resistance of the stents.
Collapse
Affiliation(s)
- ThiThuHa Phan
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA
| | - John E. Jones
- Nanova, Inc., 1601 S Providence Rd, Columbia, MO 65211, USA
| | - Yixuan Liao
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA
| | - Qingsong Yu
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA
| | - Meng Chen
- Nanova, Inc., 1601 S Providence Rd, Columbia, MO 65211, USA
| |
Collapse
|
5
|
R S, S H, Karnan H, V K, V A. Numerical modeling and analysis of cardiac stent using blood hammer principle. Technol Health Care 2024:THC240051. [PMID: 39093086 DOI: 10.3233/thc-240051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/04/2024]
Abstract
BACKGROUND Atherosclerosis is a condition which disrupts blood flow due to plaque build-up inside the arteries. Under conditions where consecutive plaques are prevailing blood hammer principle is exhibited. OBJECTIVE The pressure and shear stress produced at an infinitesimal area act as the governing equation for stent modeling. The leading order pressure lays the foundation for the design of cardiac stents with definite dimensions. METHOD The designed stent was encapsulated inside a crimper validated through ANSYS-static and transient structural simulation to derive the total deformation, equivalent strain, and stress exerted on the stent. Five different biomaterials stainless steel 316, cobalt, chromium, platinum, and Poly lactic acid were selected for the material assessment. RESULT Static and Transient structural analysis for a period of 1 and 10 secs was implemented for a stent with and without a crimper. The material performance in terms of total deformation, equivalent stress, and strain are analyzed. CONCLUSION The paper envisions the dynamics of blood hammer in atherosclerosis that provides the changes in the pressure and clotting process. It shows the promising results of the stent behavior in varied forces which gives valuable insights for future improvement in stent design and material selection.
Collapse
Affiliation(s)
- Seethalakshmi R
- School of Arts Sciences, Humanities and Education, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Hariharan S
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Hemalatha Karnan
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Keerthana V
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| | - Akshara V
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
| |
Collapse
|
6
|
Giorgianni AE, Ventura G, Hollmann J, Williams C. Blueprint for a Semi-automated Image Processing Tool to Characterize Stent Features: Application to a Pediatric Growth-Adaptive Stent. Ann Biomed Eng 2024:10.1007/s10439-024-03553-6. [PMID: 38861042 DOI: 10.1007/s10439-024-03553-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Accepted: 05/28/2024] [Indexed: 06/12/2024]
Abstract
The goal of this work was to develop a general blueprint for a semi-automated image processing tool (SIPT) to measure small, complex features of stent prototypes that can replace the current gold standard of manual measurements. The stents were designed using CAD software and manufactured via laser cutting. Stent prototypes were imaged using a Keyence microscope in top and side view orientations. The SIPT algorithm was developed in MATLAB to extract and measure 4 dimensions of the stent (inner and outer diameter, spring bend outer radius, spring bend width). The same dimensions were also manually measured by an experienced metrology technician as a gold standard comparison. We successfully made over 5000 unique measurements across the 4 key dimensions of 15 stents using the SIPT algorithm. Compared to the gold standard manual method, SIPT reduced measurement time by nearly 90% and increased the total number of measurements captured by over 2300%. The two one-sided test and Bland-Altman analysis demonstrated that SIPT achieved equivalency against the manual method of measurement for all 4 dimensions. In summary, we found that our SIPT software could be used to replace manual measurements and provided substantial time savings with consistent accuracy. Overall, this paper presents a generalizable workflow to isolate and measure critical features of stent prototypes that we believe will provide a valuable, cost-effective tool to other medical device designers seeking to rapidly iterate on unique stent designs or other manufactured parts with small and complex structures.
Collapse
Affiliation(s)
- Ava E Giorgianni
- Positioning, Navigation, and Timing Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Giselle Ventura
- Mechanical Engineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Joseph Hollmann
- Positioning, Navigation, and Timing Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Corin Williams
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA.
| |
Collapse
|
7
|
Khan MA, Khan N, Ullah M, Hamayun S, Makhmudov NI, Mbbs R, Safdar M, Bibi A, Wahab A, Naeem M, Hasan N. 3D printing technology and its revolutionary role in stent implementation in cardiovascular disease. Curr Probl Cardiol 2024; 49:102568. [PMID: 38599562 DOI: 10.1016/j.cpcardiol.2024.102568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 04/07/2024] [Indexed: 04/12/2024]
Abstract
Cardiovascular disease (CVD), exemplified by coronary artery disease (CAD), is a global health concern, escalating in prevalence and burden. The etiology of CAD is intricate, involving different risk factors. CVD remains a significant cause of mortality, driving the need for innovative interventions like percutaneous coronary intervention and vascular stents. These stents aim to minimize restenosis, thrombosis, and neointimal hyperplasia while providing mechanical support. Notably, the challenges of achieving ideal stent characteristics persist. An emerging avenue to address this involves enhancing the mechanical performance of polymeric bioresorbable stents using additive manufacturing techniques And Three-dimensional (3D) printing, encompassing various manufacturing technologies, has transcended its initial concept to become a tangible reality in the medical field. The technology's evolution presents a significant opportunity for pharmaceutical and medical industries, enabling the creation of targeted drugs and swift production of medical implants. It revolutionizes medical procedures, transforming the strategies of doctors and surgeons. Patient-specific 3D-printed anatomical models are now pivotal in precision medicine and personalized treatment approaches. Despite its ongoing development, additive manufacturing in healthcare is already integrated into various medical applications, offering substantial benefits to a sector under pressure for performance and cost reduction. In this review primarily emphasizes stent technology, different types of stents, highlighting its application with some potential complications. Here we also address their benefits, potential issues, effectiveness, indications, and contraindications. In future it can potentially reduce complications and help in improving patients' outcomes. 3DP technology offers the promise to customize solutions for complex CVD conditions and help or fostering a new era of precision medicine in cardiology.
Collapse
Affiliation(s)
- Muhammad Amir Khan
- Department of Foreign Medical Education, Fergana Medical Institute of Public Health, 2A Yangi Turon Street, Fergana 150100, Uzbekistan
| | - Niyamat Khan
- Department of Foreign Medical Education, Fergana Medical Institute of Public Health, 2A Yangi Turon Street, Fergana 150100, Uzbekistan
| | - Muneeb Ullah
- College of Pharmacy, Pusan National University, Busandaehak-ro 63 Beon-gil 2, Geumjeong-gu, Busan 46241, Republic of Korea
| | - Shah Hamayun
- Department of Cardiology, Pakistan Institute of Medical Sciences (PIMS), Islamabad, Punjab 04485, Pakistan
| | - Nurullo Ismoilovich Makhmudov
- Department of Hospital Therapy, Fergana Medical Institute of Public Health, 2A Yangi Turon Street, Fergana 150100, Uzbekistan
| | - Raziya Mbbs
- Department of Foreign Medical Education, Fergana Medical Institute of Public Health, 2A Yangi Turon Street, Fergana 150100, Uzbekistan
| | - Mishal Safdar
- Department of Biological Sciences, National University of Medical Sciences (NUMS), Rawalpindi, Punjab, Pakistan
| | - Ayisha Bibi
- Department of Pharmacy, Kohat University of Science and Technology, Khyber Pakhtunkhwa, Kohat 26000, Pakistan
| | - Abdul Wahab
- Department of Pharmacy, Kohat University of Science and Technology, Khyber Pakhtunkhwa, Kohat 26000, Pakistan
| | - Muhammad Naeem
- Department of Biological Sciences, National University of Medical Sciences (NUMS), Rawalpindi, Punjab, Pakistan
| | - Nurhasni Hasan
- Faculty of Pharmacy, Universitas Hasanuddin, Jl. Perintis Kemerdekaan Km 10, Makassar 90245, Republic of Indonesia.
| |
Collapse
|
8
|
Kokkinidou D, Kaliviotis E, Shammas C, Anayiotos A, Kapnisis K. An in vivo investigation on the effects of stent implantation on hematological and hemorheological parameters. Clin Hemorheol Microcirc 2024; 87:39-53. [PMID: 38143339 DOI: 10.3233/ch-231921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2023]
Abstract
BACKGROUND Even though cardiovascular stenting is widely used for the treatment of coronary artery disease, information on how it can affect the hematological and hemorheological profile is scarce in the literature. Most of the work on this issue is based on theoretical or computational fluid dynamics models, lacking in-depth in vitro and in vivo experimental verification. OBJECTIVE This work investigates, in an in vivo setting, the effects of stenting and the implantation time-course on hematological and hemorheological parameters that could potentially compromise the device's functionality and longevity. METHODS Custom-made self-expanding nitinol stents were implanted in the common carotid artery of male CD1 mice. Whole blood samples were collected from control (non-stented) and stented animals at 5 and 10 weeks post-implantation. Hematological measurements and blood viscosity, red blood cell aggregation, and deformability were performed using standard techniques. RESULTS Implant-induced changes were observed in some of the hematological and hemorheological indices. Blood viscosity seems to have been negatively affected by an increased hematocrit and reduced RBC deformability, at 10 weeks post-implantation, despite a slight decrease in RBC aggregation. CONCLUSIONS Although the alterations observed may be the result of the peri-implant inflammatory response, the physiological consequences due to hemorheological changes need to be further investigated.
Collapse
Affiliation(s)
- D Kokkinidou
- Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus
| | - E Kaliviotis
- Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus
| | - C Shammas
- BIOANALYSIS Clinical Laboratory, Limassol, Cyprus
| | - A Anayiotos
- Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus
| | - K Kapnisis
- Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
9
|
Carbonaro D, Lucchetti A, Audenino AL, Gries T, Vaughan TJ, Chiastra C. Multi-objective design optimization of bioresorbable braided stents. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 242:107781. [PMID: 37683458 DOI: 10.1016/j.cmpb.2023.107781] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/18/2023] [Accepted: 08/25/2023] [Indexed: 09/10/2023]
Abstract
BACKGROUND AND OBJECTIVES Bioresorbable braided stents, typically made of bioresorbable polymers such as poly-l-lactide (PLLA), have great potential in the treatment of critical limb ischemia, particularly in cases of long-segment occlusions and lesions with high angulation. However, the successful adoption of these devices is limited by their low radial stiffness and reduced elastic modulus of bioresorbable polymers. This study proposes a computational optimization procedure to enhance the mechanical performance of bioresorbable braided stents and consequently improve the treatment of critical limb ischemia. METHODS Finite element analyses were performed to replicate the radial crimping test and investigate the implantation procedure of PLLA braided stents. The stent geometry was characterized by four design parameters: number of wires, wire diameter, initial stent diameter, and braiding angle. Manufacturing constraints were considered to establish the design space. The mechanical performance of the stent was evaluated by defining the radial force, foreshortening, and peak maximum principal stress of the stent as objectives and constraint functions in the optimization problem. An approximate relationship between the objectives, constraint, and the design parameters was defined using design of experiment coupled with surrogate modelling. Surrogate models were then interrogated within the design space, and a multi-objective design optimization was conducted. RESULTS The simulation of radial crimping was successfully validated against experimental data. The radial force was found to be primarily influenced by the number of wires, wire diameter, and braiding angle, with the wire diameter having the most significant impact. Foreshortening was predominantly affected by the braiding angle. The peak maximum principal stress exhibited contrasting behaviour compared to the radial force for all parameters, with the exception of the number of wires. Among the Pareto-optimal design candidates, feasible peak maximum principal stress values were observed, with the braiding angle identified as the differentiating factor among these candidates. CONCLUSIONS The exploration of the design space enabled both the understanding of the impact of design parameters on the mechanical performance of bioresorbable braided stents and the successful identification of optimal design candidates. The optimization framework contributes to the advancement of innovative bioresorbable braided stents for the effective treatment of critical limb ischemia.
Collapse
Affiliation(s)
- Dario Carbonaro
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Agnese Lucchetti
- Institut für Textiltechnik of RWTH Aachen University, Aachen, Germany
| | - Alberto L Audenino
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Thomas Gries
- Institut für Textiltechnik of RWTH Aachen University, Aachen, Germany
| | - Ted J Vaughan
- Biomechanics Research Centre (BioMEC), School of Engineering, College of Science and Engineering, University of Galway, Ireland
| | - Claudio Chiastra
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| |
Collapse
|
10
|
Gupta K, Meena K. A novel double arrowhead auxetic coronary stent. Comput Biol Med 2023; 166:107525. [PMID: 37778216 DOI: 10.1016/j.compbiomed.2023.107525] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 08/17/2023] [Accepted: 09/19/2023] [Indexed: 10/03/2023]
Abstract
A stent implantation is a standard medical procedure for treating coronary artery diseases. Over the years, various different designs have been explored for the stents which come with a range of limitations, including late in-stent restenosis (due to low radial strength), foreshortening, radial recoil, etc. Contrary, stents with auxetic design, characterized by a negative Poisson's ratio, display unique deformation characteristics that result in enhanced mechanical properties in terms of its radial strength, radial recoil, foreshortening, and more. In this study, we have analysed a novel double arrowhead (DA) auxetic stent that aims to overcome the limitations associated with traditional stents, specifically in terms of radial strength, foreshortening, and radial recoil. The parametric analysis was done initially on the DA's unit ring structure to optimize the design by evaluating the effect of three design parameters (angle, amplitude, and width) on the mechanical characteristics (radial strength and radial recoil) using finite element analysis. The width of the strut was found to be the primary determinant of the stent structure's properties. Consequently, the angle and width were found to have the least effect on altering the stent's mechanical properties. After performing the parametric analysis, optimal design factors were selected to design the full-length DA auxetic stent. The mechanical characteristics of the DA auxetic stent were assessed and compared in a case study with the Cypher™ commercial stent. The radial strength of DA auxetic stent was found to be 7.26 N/mm, which is more than double the Cypher™ commercial stent's radial strength. Additionally, the proposed stent possesses reduced radial recoil property and completely eliminates the stent foreshortening issue, which shows the superior mechanical properties of the proposed auxetic stent and its potential as a promising candidate for future stent designs.
Collapse
Affiliation(s)
- Khanish Gupta
- Department of Mechanical Engineering, Indian Institute of Technology, Delhi, India.
| | - Kusum Meena
- Department of Mechanical Engineering, Indian Institute of Technology, Delhi, India.
| |
Collapse
|
11
|
Lang W, Huang H, Yang L, Luo R, Wang Y, Xue B, Yang S. Polymer Complex Multilayers for Drug Delivery and Medical Devices. ACS APPLIED BIO MATERIALS 2023; 6:3555-3565. [PMID: 37589742 DOI: 10.1021/acsabm.3c00404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Polymer complex multilayers (PCMs) can be engineered into various structures with tunable properties via layer-by-layer (LBL) assembly driven by noncovalent forces. Due to their ease of preparation, capability of integrating multiple functional components, and excellent substrate compliance, biocompatible PCMs as coating materials or individual entities have attracted extensive attention in biomedical applications. This Spotlight on Applications presents recent progress on PCMs applied for drug delivery and medical devices. We provide several examples to address the importance of using PCM platforms to achieve controlled drug delivery including stimuli-triggered release, sustained release, and spatiotemporal sequential release. The effects of PCM coatings on the bioresponse regulation and performance enhancement of implantable devices are also highlighted. Moreover, the design and fabrication of flexible electrical and optical elements modified with LBL PCMs have been discussed, which demonstrates the great potential to advance emerging wearable devices for disease monitoring and health management.
Collapse
Affiliation(s)
- Wenyuan Lang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Center for Advanced Low-dimension Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China
| | - Hao Huang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Center for Advanced Low-dimension Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China
| | - Li Yang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu 610064, P. R. China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu 610064, P. R. China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu 610064, P. R. China
| | - Bing Xue
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Center for Advanced Low-dimension Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China
| | - Shuguang Yang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Center for Advanced Low-dimension Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China
| |
Collapse
|
12
|
Li Y, Shi Y, Lu Y, Li X, Zhou J, Zadpoor AA, Wang L. Additive manufacturing of vascular stents. Acta Biomater 2023:S1742-7061(23)00338-0. [PMID: 37331614 DOI: 10.1016/j.actbio.2023.06.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 06/11/2023] [Accepted: 06/13/2023] [Indexed: 06/20/2023]
Abstract
With the advancement of additive manufacturing (AM), customized vascular stents can now be fabricated to fit the curvatures and sizes of a narrowed or blocked blood vessel, thereby reducing the possibility of thrombosis and restenosis. More importantly, AM enables the design and fabrication of complex and functional stent unit cells that would otherwise be impossible to realize with conventional manufacturing techniques. Additionally, AM makes fast design iterations possible while also shortening the development time of vascular stents. This has led to the emergence of a new treatment paradigm in which custom and on-demand-fabricated stents will be used for just-in-time treatments. This review is focused on the recent advances in AM vascular stents aimed at meeting the mechanical and biological requirements. First, the biomaterials suitable for AM vascular stents are listed and briefly described. Second, we review the AM technologies that have been so far used to fabricate vascular stents as well as the performances they have achieved. Subsequently, the design criteria for the clinical application of AM vascular stents are discussed considering the currently encountered limitations in materials and AM techniques. Finally, the remaining challenges are highlighted and some future research directions are proposed to realize clinically-viable AM vascular stents. STATEMENT OF SIGNIFICANCE: Vascular stents have been widely used for the treatment of vascular disease. The recent progress in additive manufacturing (AM) has provided unprecedented opportunities for revolutionizing traditional vascular stents. In this manuscript, we review the applications of AM to the design and fabrication of vascular stents. This is an interdisciplinary subject area that has not been previously covered in the published review articles. Our objective is to not only present the state-of-the-art of AM biomaterials and technologies but to also critically assess the limitations and challenges that need to be overcome to speed up the clinical adoption of AM vascular stents with both anatomical superiority and mechanical and biological functionalities that exceed those of the currently available mass-produced devices.
Collapse
Affiliation(s)
- Yageng Li
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Yixuan Shi
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Yuchen Lu
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Xuan Li
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Jie Zhou
- Department of Biomechanical Engineering, Delft University of Technology, Delft 2628 CD, The Netherlands.
| | - Amir A Zadpoor
- Department of Biomechanical Engineering, Delft University of Technology, Delft 2628 CD, The Netherlands.
| | - Luning Wang
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China.
| |
Collapse
|
13
|
Lee S, Kim N, Kwon J, Jang G. Identification of the Position of a Tethered Delivery Catheter to Retrieve an Untethered Magnetic Robot in a Vascular Environment. MICROMACHINES 2023; 14:724. [PMID: 37420957 DOI: 10.3390/mi14040724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/20/2023] [Accepted: 03/21/2023] [Indexed: 07/09/2023]
Abstract
In this paper, we propose a method of identifying the position of a tethered delivery catheter in a vascular environment, recombining an untethered magnetic robot (UMR) to the tethered delivery catheter, and safely retrieving them from the vascular environment in an endovascular intervention by utilizing a separable and recombinable magnetic robot (SRMR) and a magnetic navigation system (MNS). From images of a blood vessel and a tethered delivery catheter taken from two different angles, we developed a method of extracting the position of the delivery catheter in the blood vessel by introducing dimensionless cross-sectional coordinates. Then, we propose a retrieval method for the UMR by using the magnetic force considering the delivery catheter's position, suction force, and rotating magnetic field. We used thane MNS and feeding robot to simultaneously apply magnetic force and suction force to the UMR. In this process, we determined a current solution for generating magnetic force by using a linear optimization method. Finally, we conducted in vitro and in vivo experiments to verify the proposed method. In the in vitro experiment, which was in a glass tube environment, by using an RGB camera, we confirmed that the location of the delivery catheter in the glass tube could be recognized within an average error of 0.05 mm in each of the X- and Z-coordinates and that the retrieval success rate was greatly improved in comparison with that in the case without the use of magnetic force. In an in vivo experiment, we successfully retrieved the UMR in the femoral arteries of pigs.
Collapse
Affiliation(s)
- Serim Lee
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea
| | - Nahyun Kim
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea
| | - Junhyoung Kwon
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea
| | - Gunhee Jang
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Republic of Korea
| |
Collapse
|
14
|
Fedele G, Castiglioni S, Maier JAM, Locatelli L. The Effects of Sirolimus and Magnesium on Primary Human Coronary Endothelial Cells: An In Vitro Study. Int J Mol Sci 2023; 24:ijms24032930. [PMID: 36769252 PMCID: PMC9917770 DOI: 10.3390/ijms24032930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/27/2023] [Accepted: 01/30/2023] [Indexed: 02/05/2023] Open
Abstract
Drug eluting magnesium (Mg) bioresorbable scaffolds represent a novel paradigm in percutaneous coronary intervention because Mg-based alloys are biocompatible, have adequate mechanical properties and can be resorbed without adverse events. Importantly, Mg is fundamental in many biological processes, mitigates the inflammatory response and is beneficial for the endothelium. Sirolimus is widely used as an antiproliferative agent in drug eluting stents to inhibit the proliferation of smooth muscle cells, thus reducing the occurrence of stent restenosis. Little is known about the potential interplay between sirolimus and Mg in cultured human coronary artery endothelial cells (hCAEC). Therefore, the cells were treated with sirolimus in the presence of different concentrations of extracellular Mg. Cell viability, migration, barrier function, adhesivity and nitric oxide synthesis were assessed. Sirolimus impairs the viability of subconfluent, but not of confluent cells independently from the concentration of Mg in the culture medium. In confluent cells, sirolimus inhibits migration, while it cooperates with Mg in exerting an anti-inflammatory action that might have a role in preventing restenosis and thrombosis.
Collapse
|
15
|
Ahadi F, Azadi M, Biglari M, Bodaghi M, Khaleghian A. Evaluation of coronary stents: A review of types, materials, processing techniques, design, and problems. Heliyon 2023; 9:e13575. [PMID: 36846695 PMCID: PMC9950843 DOI: 10.1016/j.heliyon.2023.e13575] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 01/22/2023] [Accepted: 02/02/2023] [Indexed: 02/11/2023] Open
Abstract
In the world, one of the leading causes of death is coronary artery disease (CAD). There are several ways to treat this disease, and stenting is currently the most appropriate way in many cases. Nowadays, the use of stents has rapidly increased, and they have been introduced in various models, with different geometries and materials. To select the most appropriate stent required, it is necessary to have an analysis of the mechanical behavior of various types of stents. The purpose of this article is to provide a complete overview of advanced research in the field of stents and to discuss and conclude important studies on different topics in the field of stents. In this review, we introduce the types of coronary stents, materials, stent processing technique, stent design, classification of stents based on the mechanism of expansion, and problems and complications of stents. In this article, by reviewing the biomechanical studies conducted in this field and collecting and classifying their results, a useful set of information has been presented to continue research in the direction of designing and manufacturing more efficient stents, although the clinical-engineering field still needs to continue research to optimize the design and construction. The optimum design of stents in the future is possible by simulation and using numerical methods and adequate knowledge of stent and artery biomechanics.
Collapse
Affiliation(s)
- Fatemeh Ahadi
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mohammad Azadi
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mojtaba Biglari
- Faculty of Mechanical Engineering, Semnan University, Semnan, Iran
| | - Mahdi Bodaghi
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, United Kingdom
| | - Ali Khaleghian
- Department of Biochemistry, Semnan University of Medical Sciences, Semnan, Iran
| |
Collapse
|
16
|
Băilă DI, Păcurar R, Savu T, Zaharia C, Trușcă R, Nemeș O, Górski F, Păcurar A, Pleșa A, Sabău E. Mechanical and Wetting Properties of Ta 2O 5 and ZnO Coatings on Alloy Substrate of Cardiovascular Stents Manufactured by Casting and DMLS. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5580. [PMID: 36013717 PMCID: PMC9412485 DOI: 10.3390/ma15165580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 06/15/2023]
Abstract
In the last years, additive manufacturing technologies have been developed, especially direct metal laser sintering, and used in the dental and medical implant domains. Cardiovascular stents have evolved from bioinert, bare metal cages to biomimetic devices that promote tissue regeneration or healing. In this paper, comparisons concerning mechanical properties between Co-Cr alloy and cast 304L stainless steel were realized using FEM analysis, necessary for manufacturing cardiovascular stents by DMLS technology using Co-Cr alloy. The purpose of this paper consists of the evaluation of the contact angle at the interface of the Co-Cr alloy manufactured by DMLS, respectively, cast stainless steel 304L, and thin film deposition realized by the e-gun method (Ta2O5 and ZnO). Scanning electronic microscopy SEM and EDX techniques were employed for morphological investigation of the sintered samples manufactured by the DMLS process. They were also used for semi-quantitative and qualitative chemical and metallographic analyses. The e-gun coating was used to obtain thin films with the nanometer order of Ta2O5 and ZnO with a protective role to improve the corrosion resistance, roughness, and antiseptic role.
Collapse
Affiliation(s)
- Diana-Irinel Băilă
- Department of Manufacturing Engineering, Faculty of Industrial Engineering and Robotics, University Politehnica of Bucharest, Blv. Splaiul Independenței, No. 313, Sector 6, 060042 Bucharest, Romania
| | - Răzvan Păcurar
- Department of Manufacturing Engineering, Faculty of Industrial Engineering, Robotics and Production Management, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania
| | - Tom Savu
- Department of Manufacturing Engineering, Faculty of Industrial Engineering and Robotics, University Politehnica of Bucharest, Blv. Splaiul Independenței, No. 313, Sector 6, 060042 Bucharest, Romania
| | - Cătălin Zaharia
- Advanced Polymer Materials Group, Department of Bioresources and Polymer Science, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania
| | - Roxana Trușcă
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, Blv. Splaiul Independenței, No. 313, Sector 6, 060042 Bucharest, Romania
| | - Ovidiu Nemeș
- Department of Environmental Engineering and Sustainable Development Entrepreneurship, Faculty of Materials and Environmental Engineering, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania
| | - Filip Górski
- Faculty of Mechanical Engineering, Poznan University of Technology, 60-965 Poznan, Poland
| | - Ancuța Păcurar
- Department of Manufacturing Engineering, Faculty of Industrial Engineering, Robotics and Production Management, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania
| | - Alin Pleșa
- Department of Mechatronics and Machine Dynamics, Faculty of Automotive, Mechatronics and Mechanical Engineering, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania
| | - Emilia Sabău
- Department of Manufacturing Engineering, Faculty of Industrial Engineering, Robotics and Production Management, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania
| |
Collapse
|
17
|
Diamond-like Carbon Coatings in the Biomedical Field: Properties, Applications and Future Development. COATINGS 2022. [DOI: 10.3390/coatings12081088] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Repairment and replacement of organs and tissues are part of the history of struggle against human diseases, in addition to the research and development (R&D) of drugs. Acquisition and processing of specific substances and physiological signals are very important to understand the effects of pathology and treatment. These depend on the available biomedical materials. The family of diamond-like carbon coatings (DLCs) has been extensively applied in many industrial fields. DLCs have also been demonstrated to be biocompatible, both in vivo and in vitro. In many cases, the performance of biomedical devices can be effectively enhanced by coating them with DLCs, such as vascular stents, prosthetic heart valves and surgical instruments. However, the feasibility of the application of DLC in biomedicine remains under discussion. This review introduces the current state of research and application of DLCs in biomedical devices, their potential application in biosensors and urgent problems to be solved. It will be useful to build a bridge between DLC R&D workers and biomedical workers in order to develop high-performance DLC films/coatings, promote their practical use and develop their potential applications in the biomedical field.
Collapse
|
18
|
Effect of Parylene C on the Corrosion Resistance of Bioresorbable Cardiovascular Stents Made of Magnesium Alloy 'Original ZM10'. MATERIALS 2022; 15:ma15093132. [PMID: 35591466 PMCID: PMC9102321 DOI: 10.3390/ma15093132] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 04/18/2022] [Accepted: 04/25/2022] [Indexed: 02/04/2023]
Abstract
Magnesium (Mg) alloy has attracted significant attention as a bioresorbable scaffold for use as a next-generation stent because of its mechanical properties and biocompatibility. However, Mg alloy quickly degrades in the physiological environment. In this study, we investigated whether applying a parylene C coating can improve the corrosion resistance of a Mg alloy stent, which is made of 'Original ZM10', free of aluminum and rare earth elements. The coating exhibited a smooth surface with no large cracks, even after balloon expansion of the stent, and improved the corrosion resistance of the stent in cell culture medium. In particular, the parylene C coating of a hydrofluoric acid-treated Mg alloy stent led to excellent corrosion resistance. In addition, the parylene C coating did not affect a polymer layer consisting of poly(ε-caprolactone) and poly(D,L-lactic acid) applied as an additional coating for the drug release to suppress restenosis. Parylene C is a promising surface coating for bioresorbable Mg alloy stents for clinical applications.
Collapse
|
19
|
Yang B, Liu T, Gao G, Zhang X, Wu B. Fabrication of 3D GelMA Scaffolds Using Agarose Microgel Embedded Printing. MICROMACHINES 2022; 13:mi13030469. [PMID: 35334761 PMCID: PMC8948625 DOI: 10.3390/mi13030469] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/08/2022] [Accepted: 03/16/2022] [Indexed: 02/02/2023]
Abstract
Photocrosslinked Gelatin–Methacryloyl (GelMA) has been widely used in the field of 3D bioprinting due to its excellent biological properties, but its properties are not yet optimized. With the advent of embedded printing, the balance between hydrogel printability and cell viability is expected to be achieved. Agarose microgel is a good support material because of its simple preparation, good biocompatibility, high melting point, and good rheology. In this study, aiming at realizing a GelMA/Agarose suspension printing system, the printing effect of the suspension process was explored, and a suitable process printing window was defined. The resulting scaffolds showed better water absorption and elasticity, but larger deformation during printing. This study explored some potential roles of suspension baths in embedded printing, paving the way for the preparation of good suspension structures that can be convenient for customized tissue engineering applications.
Collapse
Affiliation(s)
- Bo Yang
- State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (B.Y.); (T.L.); (X.Z.)
| | - Tianqi Liu
- State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (B.Y.); (T.L.); (X.Z.)
| | - Ge Gao
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China;
| | - Xianglin Zhang
- State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (B.Y.); (T.L.); (X.Z.)
| | - Bin Wu
- State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (B.Y.); (T.L.); (X.Z.)
- Correspondence:
| |
Collapse
|
20
|
Sousa AM, Amaro AM, Piedade AP. 3D Printing of Polymeric Bioresorbable Stents: A Strategy to Improve Both Cellular Compatibility and Mechanical Properties. Polymers (Basel) 2022; 14:1099. [PMID: 35335430 PMCID: PMC8954590 DOI: 10.3390/polym14061099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/07/2022] [Accepted: 03/08/2022] [Indexed: 12/04/2022] Open
Abstract
One of the leading causes of death is cardiovascular disease, and the most common cardiovascular disease is coronary artery disease. Percutaneous coronary intervention and vascular stents have emerged as a solution to treat coronary artery disease. Nowadays, several types of vascular stents share the same purpose: to reduce the percentage of restenosis, thrombosis, and neointimal hyperplasia and supply mechanical support to the blood vessels. Despite the numerous efforts to create an ideal stent, there is no coronary stent that simultaneously presents the appropriate cellular compatibility and mechanical properties to avoid stent collapse and failure. One of the emerging approaches to solve these problems is improving the mechanical performance of polymeric bioresorbable stents produced through additive manufacturing. Although there have been numerous studies in this field, normalized control parameters for 3D-printed polymeric vascular stents fabrication are absent. The present paper aims to present an overview of the current types of stents and the main polymeric materials used to fabricate the bioresorbable vascular stents. Furthermore, a detailed description of the printing parameters' influence on the mechanical performance and degradation profile of polymeric bioresorbable stents is presented.
Collapse
Affiliation(s)
| | | | - Ana P. Piedade
- Department of Mechanical Engineering, CEMMPRE, University of Coimbra, 3030-788 Coimbra, Portugal; (A.M.S.); (A.M.A.)
| |
Collapse
|