1
|
Yoshida E, Nomoto R, Amitani Y, Hayakawa T. PEEK stress-shielding with artificial bone for dental implants. Dent Mater J 2025:2024-203. [PMID: 39805593 DOI: 10.4012/dmj.2024-203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2025]
Abstract
Dental titanium implants and their surface modifications markedly improve implant biocompatibility. However, studies evaluating the mechanical biocompatibility of implants are scarce. In particular, the analysis of mechanical biocompatibility deficiencies leading to stress shield-induced bone resorption. Recently, we focused on using PEEK as a dental material. This study explored the hypothesis that PEEK implants improve the stress shielding of titanium. In this study, artificial bone surfaces were examined to measure strains on the artificial bone surface under compressive loading with the implants in place. Additionally, 3D image analysis of the fracture state inside the bone tissue was performed using micro-CT (µCT). This hypothesis was supported by µCT imaging analysis of bone tissue changes under stress, which revealed that PEEK implants transfer greater loads than titanium implants. µCT imaging and statistical analysis showed that bone porosity had little effect on stress shielding.
Collapse
Affiliation(s)
- Eiji Yoshida
- Department of Dental Engineering, Tsurumi University School of Dental Medicine
| | - Rie Nomoto
- Department of Dental Engineering, Tsurumi University School of Dental Medicine
| | - Yasuharu Amitani
- Department of Mathematics, Tsurumi University School of Dental Medicine
| | | |
Collapse
|
2
|
Kharboush MGA, Othman HI, Aldamaty MF, Alameldin AML. Fracture resistance and mode of failure of modified Polyether-ether-ketone versus lithium disilicate endocrowns. BMC Oral Health 2025; 25:40. [PMID: 39773219 PMCID: PMC11707867 DOI: 10.1186/s12903-024-05232-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Accepted: 11/19/2024] [Indexed: 01/11/2025] Open
Abstract
PURPOSE The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass-ceramic endocrowns. MATERIALS AND METHODS A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP®) and Pressable lithium disilicate glass ceramic (IPS e.max® Press). A computer-aided design/computer-aided manufacturing system was used to digitally create and milled wax patterns. Final restorations were cemented each to its corresponding prepared tooth. Thermomechanical cycling loading representing one year of clinical service was done in a chewing simulator. Fracture resistance was evaluated utilizing a universal testing machine. The failure mode was evaluated by inspecting fractured surfaces using a Stereomicroscope and further examined by a Scanning Electron Microscope (SEM) amongst both groups. RESULTS A statistically significant variation in fracture resistance was recorded with a mean load of (2762.96 ± 216.15 N) for modified PEEK and (2175.91 ± 267.72 N) for lithium disilicate glass-ceramic endocrowns. CONCLUSION Modified PEEK endocrowns have higher fracture resistance than lithium disilicate glass-ceramic endocrowns. Moreover, the likeliness of catastrophic fracture in molars receiving endodontic treatment restored by modified PEEK is less than teeth restored with lithium disilicate glass ceramics.
Collapse
Affiliation(s)
- Mohamed G A Kharboush
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt.
| | - Hesham I Othman
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt
| | - Mohamed F Aldamaty
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt.
- Department of Restorative and Aesthetic Dentistry, College of Dentistry, Almaaqal University, Basrah, Iraq.
| | - Ahmed M L Alameldin
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt
| |
Collapse
|
3
|
Sikder P. A comprehensive review on the State of the Art in the research and development of poly-ether-ether-ketone (PEEK) biomaterial-based implants. Acta Biomater 2025; 191:29-52. [PMID: 39579846 DOI: 10.1016/j.actbio.2024.11.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2024] [Revised: 11/01/2024] [Accepted: 11/20/2024] [Indexed: 11/25/2024]
Abstract
Polyetheretherketone (PEEK) is a preferred high-performance polymer in the spine, orthopedic, and craniomaxillofacial implant industry. However, despite its commendable mechanical properties, its bioinert nature limits the implants from integrating with neighboring tissues, impacting the implant's long-term performance. To address this limitation, various kinds of surface functionalization techniques have been developed over the years. Noteworthy efforts have been made to incorporate bioactive fillers in the PEEK matrix to develop standalone bioactive composites. In personalized medicine, significant advances have been made in the 3D Printing of PEEK implants. 3D-printed PEEK implants are now being developed at Point-of-Care, significantly reducing manufacturing and logistic time. Given the recent clinical follow-up updates and advancements in PEEK-based implants, PEEK implants are witnessing an important phase in its history. Recognizing this vital phase, this paper aims to comprehensively review the advancements of PEEK implants over the past decade. The review starts with an overview of the clinical impact of varying PEEK implants, followed by PEEK's surface functionalization techniques and engineering of PEEK-based bioactive composites. Next, this review describes the advancements made in the 3D printing of PEEK implants and points out the essential considerations that should be considered when developing 3D-printed PEEK-based implants. Finally, the review ends with an estimated projection about the future of PEEK-based implants. Readers are expected to gain an all-encompassing and in-depth understanding of PEEK biomedical implants' past, present, and future, enabling researchers to advance the research and development of PEEK-based implants in the required direction. STATEMENT OF SIGNIFICANCE: PEEK is a preferred high-performance polymer in the implant industry, with notable benefits over metallic and ceramic implants, such as bone-matching stiffness and durability. Significant strides have been made in the last decade to make PEEK implants bioactive and utilize 3D Printing to develop patient-specific implants. Given the recent advancements in PEEK-based implants, this review aims to provide an all-encompassing and in-depth understanding of PEEK biomedical implants' past, present, and future. It will comprehensively discuss the know-how gained from the clinical follow-up, the strategies to address the limitations of PEEK implants, and the essential considerations in 3D Printing of PEEK implants. This review will enable researchers to advance the research and development of PEEK implants in the required direction.
Collapse
Affiliation(s)
- Prabaha Sikder
- Department of Mechanical Engineering, Cleveland State University, Cleveland, OH 44115, United States.
| |
Collapse
|
4
|
Taymour N, Abd El-Fattah A, Kandil S, Fahmy AE, Al-Qahtani NH, Khaled A, Al-Dulaijan YA, Gepreel MAH. Revolutionizing Dental Polymers: The Versatility and Future Potential of Polyetheretherketone in Restorative Dentistry. Polymers (Basel) 2024; 17:80. [PMID: 39795483 PMCID: PMC11723045 DOI: 10.3390/polym17010080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 12/22/2024] [Accepted: 12/28/2024] [Indexed: 01/13/2025] Open
Abstract
Polyetheretherketone (PEEK) has emerged as a revolutionary material in modern dentistry because of its unique combination of mechanical strength, biocompatibility, and versatility. This literature review examines the current applications and future potential of PEEK in various dental disciplines. PEEK's favorable properties, including its low specific weight, high strength-to-weight ratio, and ability to be easily machined, have led to its adoption in prosthetics, implantology, and dental esthetic restorations. This material has shown promise for fabricating crowns, bridges, removable partial denture frameworks, and implant components. PEEK's radiolucency and bone-like elastic modulus make it particularly suitable for dental implants and abutments. Additionally, its resistance to degradation and compatibility with various surface treatments enhances its long-term performance in the oral environment. While challenges such as bonding to other dental materials and aesthetic limitations exist, ongoing research is addressing these issues through surface modifications and composite formulations. As the dental field continues to evolve, PEEK's adaptability and biocompatibility position it a key player in the development of next-generation dental materials and techniques, potentially transforming patient care and treatment outcomes in dentistry.
Collapse
Affiliation(s)
- Noha Taymour
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Ahmed Abd El-Fattah
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
- Department of Chemistry, College of Science, University of Bahrain, Sakhir P.O. Box 32038, Bahrain
| | - Sherif Kandil
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
| | - Amal E. Fahmy
- Department of Dental Materials, Faculty of Dentistry, Alexandria University, Azarita, Alexandria 21526, Egypt;
| | - Naif H. Al-Qahtani
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Abdulrahman Khaled
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
| | - Yousif A. Al-Dulaijan
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Mohamed Abdel-Hady Gepreel
- Department of Materials Science and Engineering, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City 21934, Egypt;
| |
Collapse
|
5
|
Kranjec C, Mathew JP, Ovchinnikov K, Fadayomi I, Yang Y, Kjos M, Li WW. A bacteriocin-based coating strategy to prevent vancomycin-resistant Enterococcus faecium biofilm formation on materials of interest for indwelling medical devices. Biofilm 2024; 8:100211. [PMID: 39071174 PMCID: PMC11282937 DOI: 10.1016/j.bioflm.2024.100211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 06/22/2024] [Accepted: 07/02/2024] [Indexed: 07/30/2024] Open
Abstract
The ever-increasing use of exogenous materials as indwelling medical devices in modern medicine offers to pathogens new ways to gain access to human body and begin, in some cases, life threatening infections. Biofouling of such materials with bacteria or fungi is a major concern during surgeries, since this is often associated with biofilm formation and difficult to treat, recalcitrant infections. Intense research efforts have therefore developed several strategies to shield the medical devices' surface from colonization by pathogenic microorganisms. Here, we used dopamine as a coupling agent to coat four different materials of medical interest (plastic polyetheretherketone (PEEK), stainless steel, titanium and silicone catheter) with the bacteriocins, enterocin EJ97-short and the thiopeptide micrococcin P1. Water contact angle measurements and x-ray photoelectron spectroscopy were used to verify the effective coating of the materials. The effect of bacteriocins coated on these materials on the biofilm formation by a vancomycin resistant Enterococcus faecium (VRE) strain was studied by biofilm-oriented antimicrobial test (BOAT) and electron scanning microscopy. The in vitro biocompatibility of bacteriocin-modified biomaterials was tested on cultured human cells. The results demonstrated that the binding of the bacteriocins to the implant surfaces is achieved, and the two bacteriocins in combination could inhibit biofilm formation by E. faecium on all four materials. The modified implant showed no cytotoxicity to the human cells tested. Therefore, surface modification with the two bacteriocins may offer a novel and effective way to prevent biofilm formation on a wide range of implant materials.
Collapse
Affiliation(s)
- Christian Kranjec
- Laboratory of Microbial Gene Technology, Faculty of Chemistry, Biotechnology and Food Science. Norwegian University of Life Sciences, 1430, Ås, Norway
| | - Jills Puthiaparambil Mathew
- School of Pharmacy and Bioengineering, Guy Hilton Research Centre, Keele University, Stoke-on-Trent, ST4 7QB, UK
| | - Kirill Ovchinnikov
- Laboratory of Microbial Gene Technology, Faculty of Chemistry, Biotechnology and Food Science. Norwegian University of Life Sciences, 1430, Ås, Norway
| | - Idowu Fadayomi
- School of Pharmacy and Bioengineering, Guy Hilton Research Centre, Keele University, Stoke-on-Trent, ST4 7QB, UK
| | - Ying Yang
- School of Pharmacy and Bioengineering, Guy Hilton Research Centre, Keele University, Stoke-on-Trent, ST4 7QB, UK
| | - Morten Kjos
- Laboratory of Microbial Gene Technology, Faculty of Chemistry, Biotechnology and Food Science. Norwegian University of Life Sciences, 1430, Ås, Norway
| | - Wen-Wu Li
- School of Pharmacy and Bioengineering, Guy Hilton Research Centre, Keele University, Stoke-on-Trent, ST4 7QB, UK
| |
Collapse
|
6
|
Paul SM, Anitha KV, Balasubramaniam M. Effect of different agents on preload force of dental implants with bio high-performance poly-ether-ether-ketone abutments. J Oral Biol Craniofac Res 2024; 14:756-760. [PMID: 39493258 PMCID: PMC11531617 DOI: 10.1016/j.jobcr.2024.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 09/14/2024] [Accepted: 10/07/2024] [Indexed: 11/05/2024] Open
Abstract
Purpose This study evaluated the influence of different agents such as blood, artificial saliva, and normal saline on preload force of dental implants with bio-high-performance poly-ether-ether-ketone (Bio-HPP) abutments to determine its effect on screw loosening. Methods Forty (N = 40) Grade 5 titanium dental implant analog (GM Implant Analog; Neodent, Straumann) with Bio-HPP poly ether-ether ketone (PEEK) abutment and titanium screw was used in the study. The samples were embedded in acrylic split mold. In the control Group C, no agent was added. In the other three groups, blood (B), normal saline (N) and saliva (S) was added in the access cavity of the samples. A sequential torque of 15 Ncm, 20 Ncm, 25 Ncm, 30 Ncm up to 35 Ncm was applied with a digital torque meter (Eclatorq, model: SD-05bn, range:2.5-50 Ncm, torque accuracy: ± 2%cw). Samples were subjected to thermomechanical cyclic loading at 5-550 Celsius for 1000 cycles (Chewing simulator, CS 4.4) to simulate six months of clinical service. Preload was measured as reverse torque value (RTV). Raw data in the form of mean ± standard deviation was documented and subjected to statistical analysis. A one-way ANOVA was performed to contrast the groups. Tukey HSD test was used to determine the multiple comparison assessment (P < 0. 05). Results A mean reverse torque value of 35 Ncm ±0.00 was observed in both control and in groups exposed to normal saline (P >.05). Measurements of 33.4 Ncm ±2.51 and 34.8 Ncm ±0.40 were found when exposed to blood and artificial saliva in order (P < .05). When compared with control, exposure to blood showed significant variation in preload (P = .03). Conclusion A significant reduction in reverse torque force was observed when titanium implants and Bio-HPP abutments were exposed to blood, suggesting a potential risk of screw loosening (P < .05). In contrast, minimal decrease and no significant change in preload were noted with exposure to saliva and normal saline (P > .05).
Collapse
Affiliation(s)
- Sabina Mary Paul
- Department of Prosthodontics and Crown & Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, TamilNadu, India
| | - Kuttae Viswanathan Anitha
- Department of Prosthodontics and Crown & Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, TamilNadu, India
| | - Muthukumar Balasubramaniam
- Department of Prosthodontics and Crown & Bridge, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, TamilNadu, India
| |
Collapse
|
7
|
Abdel Hamid SM, Selima RA, Basiony MZ. Surface topography changes and wear resistance of different non-metallic telescopic crown attachment materials in implant retained overdenture (prospective comparative in vitro study). BMC Oral Health 2024; 24:1123. [PMID: 39327589 PMCID: PMC11430128 DOI: 10.1186/s12903-024-04839-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Accepted: 08/29/2024] [Indexed: 09/28/2024] Open
Abstract
BACKGROUND The purpose of this study was to evaluate the effect of using different types of metallic and non-metallic telescopic crown attachment materials on wear resistance and surface tomography changes in implant-retained mandibular overdentures. MATERIALS AND METHODS Completely edentulous mandibular epoxy models were fabricated, in which two implants were placed in the canine region and retained to the implants with three different material combinations used for the construction of telescopic attachments. Thirty-three identical mandibular overdentures were fabricated using the conventional standardized technique. The study groups were divided into three categories according to the material used for the construction of the secondary copings. The primary copings in all the study groups were constructed of PEEK, while the secondary coping in group I was PEEK, group II was ZrO2 and CoCr for group III. Primary copings were cemented on a ready-made abutment. Secondary copings were placed over the primary copings in the desired path of insertion, then picked up into the intaglio surface of the overdentures. A cyclic loading machine was used to apply repeated insertion-removal cycles simulating nearly 10 years of clinical use. Stereomicroscope with a built-in camera was used to monitor the reduction in width of the primary copings to evaluate the wear resistance of each material combination. RESULTS There was highly statistically significant difference between the study groups after the application of 1.000, 5.000 and 10.000 cycles. The highest level of wear resistance was recorded for the PEEK/PEEK combination, whereas PEEK/ZrO2 and PEEK/CoCr showed no significant differences. CONCLUSIONS Implant retained overdenture with PEEK-PEEK telescopic crown attachment is associated with the highest wear resistance among all the study groups. PEEK-PEEK combination may be the treatment of choice for fabrication of telescopic attachment in implant retained overdenture as it provides better resistance to wear. It offers the advantages for geriatric patients as it decreases the possibility for repeated repair and replacement of attachment, increase long-term patient satisfaction and shelf life of prosthesis.
Collapse
Affiliation(s)
- Sherif M Abdel Hamid
- Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt
| | - Rim A Selima
- Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt.
| | - Mohamed Z Basiony
- Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt
| |
Collapse
|
8
|
Bassiouny D, Petersmann S, Zohdy M, Morsi T, Taha D. Trueness and intaglio fit of custom-made polyetheretherketone post-and-cores fabricated using different techniques. J Prosthet Dent 2024:S0022-3913(24)00457-8. [PMID: 39089926 DOI: 10.1016/j.prosdent.2024.06.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2024] [Revised: 06/28/2024] [Accepted: 06/28/2024] [Indexed: 08/04/2024]
Abstract
STATEMENT OF PROBLEM Applications of polyetheretherketone (PEEK) as a promising alternative to ceramic materials have extended to include post-and-cores. However, information regarding the available fabrication techniques for producing custom-made PEEK post-and-cores and their effect on accuracy is still scarce. PURPOSE The purpose of this in vitro study was to evaluate the trueness and intaglio fit of custom-made PEEK post-and-cores fabricated using different techniques. MATERIAL AND METHODS Ten mandibular second premolars were collected, decoronated, and endodontically treated. For the fabrication of custom-made post-and-cores, each post space was prepared, scanned, and designed by using the exocad software program. Each reference design was used to fabricate PEEK post-and-cores with 3 different techniques (N=30): group P, heat pressing; group S, subtractive manufacturing, and group A, additive manufacturing. All the fabricated restorations were scanned, providing the test data as standard tessellation language (STL) files, which were imported with the reference data into a reverse engineering software program to evaluate the 3D trueness of each fabrication technique. To evaluate the intaglio fit, restorations coated with silicone material were scanned to provide the test data as STL files, which were superimposed on the STL files of the scanned restorations. One-way analysis of variance (ANOVA) and 2-way mixed model ANOVA tests were used to analyze the data (α=.05). RESULTS For 3D trueness, root mean square (RMS) values representing the deviations between the scans of the fabricated restorations and the reference designs varied significantly among different groups (P<.001), with the highest mean deviation found in group A (102.8 ±31 µm), while the lowest mean deviation was found in group S (42.2 ±11 µm). For the intaglio fit, the deviations between the scans of the fabricated restorations and the scans of the coated restorations varied significantly among different groups (P<.001), with the highest mean deviation found in group A (228.4 ±47 µm), while the lowest mean deviation was found in group S (96.2 ±14 µm). Simple effects comparisons showed the highest value of deviation in the apical area in group A (P<.001). CONCLUSIONS Custom-made PEEK post-and-cores fabricated by using subtractive manufacturing and heat pressing techniques showed better trueness and intaglio fit compared with additively manufactured restorations. Before printed PEEK restorations can be considered a suitable alternative to pressed or milled ones, improvements are required to confirm their reliability.
Collapse
Affiliation(s)
- Dina Bassiouny
- Assistant Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Sandra Petersmann
- Senior Researcher, DMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria
| | - Maged Zohdy
- Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Tarek Morsi
- Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt; and Vice Dean of Postgraduate Affairs, Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt
| | - Doaa Taha
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt; Associate Professor, Department of Fixed Prosthodontics, School of Dentistry, Newgiza University, Giza, Egypt; and Visiting Researcher, Section Medical Materials Science & Technology, University Hospital Tübingen, Tübingen, Germany.
| |
Collapse
|
9
|
Sacks G, Shah V, Yao L, Yan C, Shah D, Limeta L, DeStefano V. Polyaryletherketones: Properties and applications in modern medicine. BIOMEDICAL TECHNOLOGY 2024; 6:75-89. [DOI: 10.1016/j.bmt.2023.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
|
10
|
Martinez-Mondragon M, Urriolagoitia-Sosa G, Romero-Ángeles B, García-Laguna MA, Laguna-Canales AS, Pérez-Partida JC, Mireles-Hernández J, Carrasco-Hernández F, Urriolagoitia-Calderón GM. Biomechanical Fatigue Behavior of a Dental Implant Due to Chewing Forces: A Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1669. [PMID: 38612181 PMCID: PMC11012472 DOI: 10.3390/ma17071669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/20/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024]
Abstract
The use of titanium as a biomaterial for the treatment of dental implants has been successful and has become the most viable and common option. However, in the last three decades, new alternatives have emerged, such as polymers that could replace metallic materials. The aim of this research work is to demonstrate the structural effects caused by the fatigue phenomenon and the comparison with polymeric materials that may be biomechanically viable by reducing the stress shielding effect at the bone-implant interface. A numerical simulation was performed using the finite element method. Variables such as Young's modulus, Poisson's coefficient, density, yield strength, ultimate strength, and the S-N curve were included. Prior to the simulation, a representative digital model of both a dental implant and the bone was developed. A maximum load of 550 N was applied, and the analysis was considered linear, homogeneous, and isotropic. The results obtained allowed us to observe the mechanical behavior of the dental implant by means of displacements and von Mises forces. They also show the critical areas where the implant tends to fail due to fatigue. Finally, this type of non-destructive analysis proves to be versatile, avoids experimentation on people and/or animals, and reduces costs, and the iteration is unlimited in evaluating various structural parameters (geometry, materials, properties, etc.).
Collapse
Affiliation(s)
- Miguel Martinez-Mondragon
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Guillermo Urriolagoitia-Sosa
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Beatriz Romero-Ángeles
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Miguel Angel García-Laguna
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Aldo Saul Laguna-Canales
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Juan Carlos Pérez-Partida
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Jonatan Mireles-Hernández
- Universidad Abierta y a Distancia de México, División de Ciencias de la Salud, Biológicas y Ambientales, Av. Universidad 1200, Piso 1, Cuadrante 10, 1-2, Xoco, Alcaldía Benito Juárez, Ciudad de México C.P. 03330, Mexico
| | - Francisco Carrasco-Hernández
- Universidad Tecnológica de Durango, Mecatrónica y Energías Renovables, Carretera Durango-Mezquital, km 4.5 S/N, Gavino Santillán, Durango C.P. 34308, Mexico
| | - Guillermo Manuel Urriolagoitia-Calderón
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| |
Collapse
|
11
|
Ghanem N, Ali H, Bahrli N, Hassan H. Clinical performance of custom-milled polyetherketoneketone (PEKK) posts and cores: A 12-month follow-up randomized controlled pilot study. Clin Exp Dent Res 2024; 10:e854. [PMID: 38433309 PMCID: PMC10909799 DOI: 10.1002/cre2.854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/12/2023] [Accepted: 01/26/2024] [Indexed: 03/05/2024] Open
Abstract
OBJECTIVES Comparing the survival rate and the cumulative success rates of custom-milled polyetherketone ketone posts and cores (MPP) with prefabricated fiber posts (PFP) in restoring compromised endodontically treated premolars. MATERIAL AND METHODS This was a randomized, double-blind, parallel, two-arm controlled pilot study. A total of 24 patients (12 males, 12 females), each had a compromised lower premolar, needed a root canal treatment and to be restored with post and core. Patients were randomly allocated into two groups, MPP-group: restored with MPP, and PFP-group: restored with PFP and composite cores. After that, premolars were restored with single porcelain fused to metal (PFM) crowns. Clinical and radiographic follow-ups were conducted after 3, 6, and 12 months. The Kaplan-Meier, log-Rank, and χ2 tests were used to investigate differences between the two groups at the 0.05 significance level. RESULTS The survival rate after 12 months in the MPP and PFP groups was 66.7% and 100%, respectively. Meanwhile, the cumulative success rates were 63.6% and 100% in the same order. The log-rank test showed a significant difference between the two groups (p = .031). The difference in cumulative success rates was also significant, as the χ2 test revealed (p = .011). CONCLUSION The PFP group showed a higher success rate than the MPP group and according to the failure types, PEKK posts seem to be inferior to PFP in terms of the mechanical properties and bonding to resin mechanism. TRIAL REGISTRATION ISRCTN, ISRCTN13456471. October, 14, 2019. (https://doi.org/10.1186/ISRCTN13456471ISRCTN13456471).
Collapse
Affiliation(s)
- Naif Ghanem
- Department of Fixed Prosthodontics, Faculty of DentistryTishreen UniversityLatakiaSyria
| | - Hasan Ali
- Department of Pediatric Dentistry, Faculty of DentistryTishreen UniversityLatakiaSyria
| | - Nasser Bahrli
- Department of Fixed Prosthodontics, Faculty of DentistryTishreen UniversityLatakiaSyria
| | - Hazem Hassan
- Department of Orthodontics, Faculty of DentistryTishreen UniversityLatakiaSyria
| |
Collapse
|
12
|
Omatsu K, Yamawaki I, Taguchi Y, Tsumori N, Hashimoto Y, Umeda M. Surface modification affects human gingival epithelial cell behavior on polyetheretherketone surfaces. Dent Mater J 2024; 43:191-199. [PMID: 38246630 DOI: 10.4012/dmj.2023-196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
Gingival epithelial attachment to the abutment is important for the prevention of peri-implantitis. Polyetheretherketone (PEEK) has recently gained attention as an alternative material to titanium; however, it is biologically inert, which is disadvantageous for obtaining soft tissue sealing of the transmucosal part of the implant abutment. Therefore, ultraviolet (UV) irradiation, argon plasma irradiation, and buffing were selected as treatments to modify the PEEK surface. None of the treatments had any effect on the material's mechanical strength. The UV and plasma treatments did not significantly affect the surface morphology. Surface elemental analysis showed a decrease in carbon content and an increase in oxygen content and wettability for all treatments. Human gingival epithelial cell adhesion, proliferation, and the expression of adhesion proteins integrin β4 and laminin 332, were increased. Surface modification to PEEK was suggested to enhance cell activity on PEEK.
Collapse
Affiliation(s)
- Keiju Omatsu
- Department of Periodontology, School of Dentistry, Osaka Dental University
| | - Isao Yamawaki
- Department of Periodontology, School of Dentistry, Osaka Dental University
| | - Yoichiro Taguchi
- Department of Periodontology, School of Dentistry, Osaka Dental University
| | - Norimasa Tsumori
- Department of Periodontology, School of Dentistry, Osaka Dental University
| | - Yoshiya Hashimoto
- Department of Biomaterials, School of Dentistry, Osaka Dental University
| | - Makoto Umeda
- Department of Periodontology, School of Dentistry, Osaka Dental University
| |
Collapse
|
13
|
Kaya N, Sasany R, Yanıkoglu N, Tosun B. Investigation of color and physicomechanical properties of peek and pekk after storage in a different medium. Sci Rep 2024; 14:5357. [PMID: 38438417 PMCID: PMC10912655 DOI: 10.1038/s41598-024-54695-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 02/15/2024] [Indexed: 03/06/2024] Open
Abstract
The aim of this study is to assess color stability, solubility, and water sorption on polyether ether ketone (PEEK) and polyether ketone ketone (PEKK) after immersion in different storage conditions. Material and Methods Ninety disc-shaped specimens (8 × 2) were obtained from CAD/CAM blocks [PEEK (n = 45) and PEKK (n = 45)]. Before immersion, baseline color value data were recorded with a spectrophotometer. The specimens were soaked in three solutions red wine, coffee, and distilled water at 37 °C for 28 days. Following immersion, color values were remeasured, and color-change values (ΔE) were calculated. Water sorption and solubility were assessed by mass gain or loss after storage in water for 28 days. The Kruskal-Wallis and the Mann-Whitney U test were used for analysis (P = 0.05). Results ΔE00 between PEEK and PEKK was significantly different statistically (P < 0.001). PEEK presented higher water sorption than PEKK (P = 0.005). The difference in solubility between PEEK and PEKK was not statistically significant (P = 0.163). The materials and storage medium types had a statistically significant impact (P = 0.100). In terms of staining potential, the solutions tested in this experiment were ranked as: coffee > red wine > distilled water. The results of this study demonstrated that PEKK was more successful in polymer-containing CAD/CAM materials as it exhibited less color change and water absorption.
Collapse
Affiliation(s)
- Nihan Kaya
- Department of Prosthodontics, Faculty of Dentistry, University of Giresun, Giresun, Turkey
| | - Rafat Sasany
- Department of Prosthodontics, Faculty of Dentistry, University of Biruni, İstanbul, Turkey.
| | - Nuran Yanıkoglu
- Department of Prosthodontics, Faculty of Dentistry, University of Ataturk, Erzurum, Turkey
| | - Busra Tosun
- Department of Prosthodontics, Faculty of Dentistry, University of Abant İzzet Baysal, Bolu, Turkey
| |
Collapse
|
14
|
Frąckiewicz W, Królikowski M, Kwiatkowski K, Sobolewska E, Szymlet P, Tomasik M. Comparison of Dental Zirconium Oxide Ceramics Produced Using Additive and Removal Technology for Prosthodontics and Restorative Dentistry-Strength and Surface Tests: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 17:168. [PMID: 38204022 PMCID: PMC10779906 DOI: 10.3390/ma17010168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 12/14/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024]
Abstract
BACKGROUND The aim of this in vitro study was to determine the mechanical and functional properties of zirconium oxide ceramics made using 3D printing technology and ceramics produced using conventional dental milling machines. METHODS Forty zirconia samples were prepared for this study: the control group consisted of 20 samples made using milling technology, and the test group consisted of 20 samples made using 3D printing technology. Their surface parameters were measured, and then their mechanical parameters were checked and compared. Density, hardness, flexural strength and compressive strength were tested by performing appropriate in vitro tests. After the strength tests, a comparative analysis of the geometric structure of the surfaces of both materials was performed again. Student's t-test was used to evaluate the results (p < 0.01). RESULTS Both ceramics show comparable values of mechanical parameters, and the differences are not statistically significant. The geometric structure of the sample surfaces looks very similar. Only minor changes in the structure near the crack were observed in the AM group. CONCLUSION Ceramics made using additive technology have similar mechanical and surface parameters to milled zirconium oxide, which is one of the arguments for the introduction of this material into clinical practice. This in vitro study has shown that this ceramic can compete with zirconium made using CAD/CAM (Computer-Aided Design and Computer-Aided Manufacturing) methods.
Collapse
Affiliation(s)
- Wojciech Frąckiewicz
- Department of Dental Prosthetics, Faculty of Medicine and Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
| | - Marcin Królikowski
- Department of Manufacturing Engineering, Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 70-310 Szczecin, Poland
| | - Konrad Kwiatkowski
- Department of Mechanics and Fundamentals of Machine Design, Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 70-310 Szczecin, Poland
| | - Ewa Sobolewska
- Department of Dental Prosthetics, Faculty of Medicine and Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
| | - Paweł Szymlet
- Department of Dental Prosthetics, Faculty of Medicine and Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
| | - Małgorzata Tomasik
- Department of Interdisciplinary Dentistry, Faculty of Medicine and Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
| |
Collapse
|
15
|
Sahm BD, Teixeira ABV, dos Reis AC. Graphene loaded into dental polymers as reinforcement of mechanical properties: A systematic review. JAPANESE DENTAL SCIENCE REVIEW 2023; 59:160-166. [PMID: 37362606 PMCID: PMC10285463 DOI: 10.1016/j.jdsr.2023.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 05/23/2023] [Accepted: 06/11/2023] [Indexed: 06/28/2023] Open
Abstract
Graphene compounds are incorporated into polymers in order to improve their mechanical properties and in dentistry this modification favors the clinical performance of these materials. The aim of this review was to evaluate graphene compounds, their concentrations, and their effect on mechanical properties as flexural, tensile, and compressive strength and hardness of polymethylmethacrylate (PMMA) and polyether-ether-ketone (PEEK) for dental application. The search was carried out in two steps in PubMed/Medline, Embase, Scopus, and Web of Science databases. The eligibility criteria included studies that incorporated pure graphene compounds into dental polymers and evaluated their mechanical properties. Were found 4984 results, of which 11 articles were included in this review. Graphene compounds: graphene oxide (GO), reduced graphene oxide (rGO), and graphene nanoplatelets (GNP) were incorporated into PMMA and PEEK, in concentrations ranging from 0.1 to 10 wt%. Concentrations lower than 0.75 wt% of GO in PMMA and 1 wt% of GNP in PEEK resulted in increased flexural, tensile, compression strength, and hardness of these polymers. It was concluded that the incorporation of graphene compounds in low concentrations increases dental polymers' mechanical properties.
Collapse
Affiliation(s)
| | | | - Andréa Cândido dos Reis
- Correspondence to: Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Av. Do Café, s/n, 14040-904 Ribeirão Preto, SP, Brazil.
| |
Collapse
|
16
|
Lyu X, Kanda R, Tsuda S, Hashimoto Y, Fujii T, Kashiwagi K. Novel Carboxylation Method for Polyetheretherketone (PEEK) Surface Modification Using Friedel-Crafts Acylation. Int J Mol Sci 2023; 24:15651. [PMID: 37958636 PMCID: PMC10650194 DOI: 10.3390/ijms242115651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023] Open
Abstract
Recently, polyetheretherketone (PEEK) has shown promising dental applications. Surface treatment is essential for dental applications owing to its poor surface energy and wettability; however, no consensus on an effective treatment method has been achieved. In this study, we attempted to carboxylate PEEK sample surfaces via Friedel-Crafts acylation using succinic anhydride and AlBr3. The possibility of further chemical modifications using carboxyl groups was examined. The samples were subjected to dehydration-condensation reactions with 1H,1H-pentadecafluorooctylamine and N,N'-dicyclohexylcarbodiimide. Furthermore, the sample's surface properties at each reaction stage were evaluated. An absorption band in the 3300-3500 cm-1 wavenumber region was observed. Additionally, peak suggestive of COOH was observed in the sample spectra. Secondary modification diminished the absorption band in 3300-3500 cm-1 and a clear F1s signal was observed. Thus, Friedel-Crafts acylation with succinic anhydride produced carboxyl groups on the PEEK sample surfaces. Further chemical modification of the carboxyl groups by dehydration-condensation reactions is also possible. Thus, a series of reactions can be employed to impart desired chemical structures to PEEK surfaces.
Collapse
Affiliation(s)
- Xinghui Lyu
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Ryuhei Kanda
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Susumu Tsuda
- Department of Chemistry, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Yoshiya Hashimoto
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
- Department of Biomaterial, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| | - Takamasa Fujii
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Kosuke Kashiwagi
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| |
Collapse
|
17
|
Win PP, Chen DDS, Sainbayar B, Peng TY, Cheng JHC. Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers. J Dent Sci 2023; 18:1804-1811. [PMID: 37799918 PMCID: PMC10548050 DOI: 10.1016/j.jds.2023.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 05/20/2023] [Indexed: 10/07/2023] Open
Abstract
Background/purpose Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). Materials and methods Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. Results The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. Conclusion Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs.
Collapse
Affiliation(s)
- Pyi Phyo Win
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Division of Orthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan
| | - Daniel De-Shing Chen
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Division of Orthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan
| | - Bolormaa Sainbayar
- School of Dentistry, Mongolian National University of Medical Sciences, Ulaanbaatar City, Mongolia
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Johnson Hsin-Chung Cheng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Division of Orthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan
| |
Collapse
|
18
|
Pu F, Yu Y, Zhang Z, Wu W, Shao Z, Li C, Feng J, Xue L, Chen F. Research and Application of Medical Polyetheretherketone as Bone Repair Material. Macromol Biosci 2023; 23:e2300032. [PMID: 37088909 DOI: 10.1002/mabi.202300032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 04/01/2023] [Indexed: 04/25/2023]
Abstract
Polyetheretherketone (PEEK) can potentially be used for bone repair because its elastic modulus is similar to that of human natural bone and good biocompatibility and chemical stability. However, its hydrophobicity and biological inertness limit its application in the biomedical field. Inspired by the composition, structure, and function of bone tissue, many strategies are proposed to change the structure and functionality of the PEEK surface. In this review, the applications of PEEK in bone repair and the optimization strategy for PEEK's biological activity are reviewed, which provides a direction for the development of multifunctional bone repair materials in the future.
Collapse
Affiliation(s)
- Feifei Pu
- Department of Orthopedics, Traditional Chinese and Western Medicine Hospital of Wuhan (Wuhan No.1 Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Yihan Yu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Zhicai Zhang
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Wei Wu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Zengwu Shao
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Chao Li
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Jing Feng
- Department of Orthopedics, Traditional Chinese and Western Medicine Hospital of Wuhan (Wuhan No.1 Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Longjian Xue
- School of Power and Mechanical Engineering, Wuhan University, Wuhan, Hubei, 430072, China
| | - Fengxia Chen
- Department of Radiation and Medical Oncology, Zhongnan Hospital, Wuhan University, Wuhan, Hubei, 430071, China
| |
Collapse
|
19
|
Dghaily D, Rayyan M, Ragab H, Sayed M, Ayash G, Alzahrani G. Comparison of Fracture Resistance between Different Treatment Modalities of Mutilated Endodontically Treated Teeth Using Polyether Ether Ketone. J Contemp Dent Pract 2023; 24:668-673. [PMID: 38152940 DOI: 10.5005/jp-journals-10024-3558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
AIM To compare fracture resistance of multiple treatment modalities intended for mutilated teeth using polyether ether ketone (PEEK) and zirconia materials. MATERIALS AND METHODS The study was divided into four groups according to treatment modality adopted (n = 14): fiber post (F), Nayyar core (N), endocrown (E), and Richmond crown (R). Each group was further subdivided into two groups (n = 7) according to the type of material used: zirconia (Z) and PEEK (P). Using computer-aided design/computer-aided manufacturing, restorations were constructed from both materials following tested treatment options and manufacturer direction. Finished restorations were then tried, seated, and cemented to their corresponding acrylic teeth. All specimens were tested for fracture resistance in universal testing machine with cross head speed of 0.5 mm/min speed until failure, which was confirmed by a sudden drop in the measurements of the testing machine. Results were recorded, tabulated, and statistically analyzed. Shapiro-Wilk normality tests were considered to evaluate the normality of the data distributions. One-way analysis of variance (ANOVA) followed by Tukey's post hoc analysis was conducted to analyze the fracture resistance significant differences. RESULTS Descriptive statistics of the restoration material revealed statistically a higher mean value for PEEK material (3609 ± 188.1) than zirconia (2404 ± 425.6). One-way ANOVA revealed statistically significant differences between zirconia group (p < 0.0001). Regarding zirconia group statistical significance was detected between fiber post vs endocrown (p = 0.0299), fiber post vs Richmond crown (p < 0.0001), and Nayyar core vs Richmond crown (p = 0.0004). However, there was no statistically significant difference between PEEK group (P = 0.1614). CONCLUSION Polyether ether ketone could present a reliable treatment option in endodontically treated teeth. CLINICAL SIGNIFICANCE Using one-piece Richmond crowns constructed of PEEK could present a viable treatment option against conventional treatment options of root canal treatment (RCT) single-rooted teeth.
Collapse
Affiliation(s)
- Diana Dghaily
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohammad Rayyan
- Department of Fixed Prosthodontics, Faculty of Dentistry, Sinai University, Kantara Campus, Sinai, Egypt
| | - Hala Ragab
- Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohamed Sayed
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ahram Canadian University, Egypt, Phone: +20 1288670943, e-mail:
| | - Ghada Ayash
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Ghadah Alzahrani
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| |
Collapse
|
20
|
Le Bars P, Bandiaky ON, Le Guéhennec L, Clouet R, Kouadio AA. Different Polymers for the Base of Removable Dentures? Part I: A Narrative Review of Mechanical and Physical Properties. Polymers (Basel) 2023; 15:3495. [PMID: 37688123 PMCID: PMC10490543 DOI: 10.3390/polym15173495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/14/2023] [Accepted: 08/17/2023] [Indexed: 09/10/2023] Open
Abstract
Even before considering their introduction into the mouth, the choice of materials for the optimization of the prosthesis depends on specific parameters such as their biocompatibility, solidity, resistance, and longevity. In the first part of this two-part review, we approach the various mechanical characteristics that affect this choice, which are closely related to the manufacturing process. Among the materials currently available, it is mainly polymers that are suitable for this use in this field. Historically, the most widely used polymer has been polymethyl methacrylate (PMMA), but more recently, polyamides (nylon) and polyether ether ketone (PEEK) have provided interesting advantages. The incorporation of certain molecules into these polymers will lead to modifications aimed at improving the mechanical properties of the prosthetic bases. In the second part of the review, the safety aspects of prostheses in the oral ecosystem (fragility of the undercuts of soft/hard tissues, neutral pH of saliva, and stability of the microbiota) are addressed. The microbial colonization of the prosthesis, in relation to the composition of the material used and its surface conditions (roughness, hydrophilicity), is of primary importance. Whatever the material and manufacturing process chosen, the coating or finishes dependent on the surface condition remain essential (polishing, non-stick coating) for limiting microbial colonization. The objective of this narrative review is to compile an inventory of the mechanical and physical properties as well as the clinical conditions likely to guide the choice between polymers for the base of removable prostheses.
Collapse
Affiliation(s)
- Pierre Le Bars
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Octave Nadile Bandiaky
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Laurent Le Guéhennec
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Roselyne Clouet
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Alain Ayepa Kouadio
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Department of Prosthetic Dentistry, Faculty of Dentistry, University Hospital Center, Abidjan P.O. Box 612, Côte d’Ivoire
| |
Collapse
|
21
|
Yildiz S, Tekin S, Kizilkaya AR, Akgün SE, Deger Y. Comparative Stress Analysis of Custom-Made PEEK Dental Post-Cores versus Conventional Post-Cores in Incisor Restorations: A Finite Element Study. Med Sci Monit 2023; 29:e940887. [PMID: 37587670 PMCID: PMC10443227 DOI: 10.12659/msm.940887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 07/07/2023] [Indexed: 08/18/2023] Open
Abstract
BACKGROUND We conducted a finite element analysis to evaluate stress levels in incisor teeth restored with custom polyetheretherketone (PEEK) dental post-cores compared to conventional post-cores. MATERIAL AND METHODS Using micro-computed tomography (μCT) imaging data, a 3D model of a maxillary incisor was created. For each material type, 3D mesh models were developed via specialized software. Two post diameters, 2.5 mm and 3.5 mm, were considered. Five different post materials were examined: Unfilled polyetheretherketone (Group UP); Glass fiber-reinforced polyetheretherketone (Group GP); Carbon fiber-reinforced polyetheretherketone (Group CP); Metal (Group M); and Zirconia ceramic (Group Z). Each model underwent finite element analysis, after which the von Mises equivalent stress values were determined. RESULTS For models involving both wide and narrow diameter posts across the crown, crown cement, post cement, and dentin, PEEK posts (Group UP, GP, and CP) exhibited higher von Mises stress values than Groups Z and M. However, the reverse trend was noticed in the post model itself. In the post cement model, stress values appeared similar only for the narrow-diameter post groups. Notably, results for Groups Z and M were largely consistent with each other. CONCLUSIONS PEEK posts, which have a lower modulus of elasticity, demonstrated different stress values when contrasted with zirconia and metal posts. As the post diameter expanded, the residual dentin decreased, influencing the stress values among various materials. Further in vitro and clinical examinations are essential to comprehensively understand PEEK posts.
Collapse
Affiliation(s)
- Semsettin Yildiz
- Department of Pediatric Dentistry, Faculty of Dentistry, Firat University, Elazig, Turkey
| | - Samet Tekin
- Department of Prosthodontics, Faculty of Dentistry, Firat University, Elazig, Turkey
| | | | - Semih Ercan Akgün
- Pediatric Dentistry Clinic, Bafra Oral and Dental Health Center, Samsun, Turkey
| | - Yalcin Deger
- Department of Prosthodontics, Faculty of Dentistry, Dicle University, Diyarbakir, Turkey
| |
Collapse
|
22
|
Su Q, Qiao Y, Xiao Y, Yang S, Wu H, Li J, He X, Hu X, Yang H, Yong X. Research progress of 3D printed poly (ether ether ketone) in the reconstruction of craniomaxillofacial bone defects. Front Bioeng Biotechnol 2023; 11:1259696. [PMID: 37662437 PMCID: PMC10469012 DOI: 10.3389/fbioe.2023.1259696] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 08/07/2023] [Indexed: 09/05/2023] Open
Abstract
The clinical challenge of bone defects in the craniomaxillofacial region, which can lead to significant physiological dysfunction and psychological distress, persists due to the complex and unique anatomy of craniomaxillofacial bones. These critical-sized defects require the use of bone grafts or substitutes for effective reconstruction. However, current biomaterials and methods have specific limitations in meeting the clinical demands for structural reinforcement, mechanical support, exceptional biological performance, and aesthetically pleasing reconstruction of the facial structure. These drawbacks have led to a growing need for novel materials and technologies. The growing development of 3D printing can offer significant advantages to address these issues, as demonstrated by the fabrication of patient-specific bioactive constructs with controlled structural design for complex bone defects in medical applications using this technology. Poly (ether ether ketone) (PEEK), among a number of materials used, is gaining recognition as a feasible substitute for a customized structure that closely resembles natural bone. It has proven to be an excellent, conformable, and 3D-printable material with the potential to replace traditional autografts and titanium implants. However, its biological inertness poses certain limitations. Therefore, this review summarizes the distinctive features of craniomaxillofacial bones and current methods for bone reconstruction, and then focuses on the increasingly applied 3D printed PEEK constructs in this field and an update on the advanced modifications for improved mechanical properties, biological performance, and antibacterial capacity. Exploring the potential of 3D printed PEEK is expected to lead to more cost-effective, biocompatible, and personalized treatment of craniomaxillofacial bone defects in clinical applications.
Collapse
Affiliation(s)
- Qiao Su
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Department of Paediatrics, West China Second University Hospital, State Key Laboratory of Biotherapy and Collaborative Innovation Center of Biotherapy, Sichuan University, Chengdu, Sichuan, China
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases and West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Yixin Qiao
- Department of Otolaryngology-Head and Neck Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yile Xiao
- Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Shuhao Yang
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
| | - Haoming Wu
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
| | - Jianan Li
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Xinlong He
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Xulin Hu
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Hui Yang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases and West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Xin Yong
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Department of Paediatrics, West China Second University Hospital, State Key Laboratory of Biotherapy and Collaborative Innovation Center of Biotherapy, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
23
|
Arshad M, Hassantash S, Chinian S, Sadr A, Habibzadeh S. Fracture strength and three-dimensional marginal evaluation of biocompatible high-performance polymer versus pressed lithium disilicate crowns. J Prosthet Dent 2023:S0022-3913(23)00269-X. [PMID: 37208243 DOI: 10.1016/j.prosdent.2023.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 04/15/2023] [Accepted: 04/19/2023] [Indexed: 05/21/2023]
Abstract
STATEMENT OF PROBLEM Despite the acceptable physical properties of biocompatible high-performance polymer (BioHPP), little is known about the marginal accuracy and fracture strength of restorations made from this material. PURPOSE This in vitro study assessed the marginal and internal adaptation and fracture strength of teeth restored with lithium disilicate (LD) ceramics and BioHPP monolithic crowns. MATERIAL AND METHODS Twenty-four extracted premolars were prepared for complete coverage crowns and divided into 2 groups to receive pressed IPS e.max LD, or computer-aided design and computer-aided manufacturing (CAD-CAM) BioHPP monolithic crowns. After adhesive cementation, the marginal and internal adaptations of the restorations were evaluated by microcomputed tomography at 18 points for each crown. Specimens were subjected to 6000 thermal cycles at 5 °C and 55 °C and 200 000 load cycles of 100 N at a frequency of 1.2 Hz. The fracture strength of the restorations was then measured in a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed via an independent-sample t-test (α=.05). RESULTS The mean ±standard deviation of marginal gap was 138.8 ±43.6 μm for LD and 242.1 ±70.7 μm for BioHPP groups (P=.001). The mean ±standard deviation value of absolute marginal discrepancy was 193.8 ±60.8 μm for LD and 263.5 ±97.6 μm for BioHPP groups (P=.06). The internal occlusal and axial gap measurements were 547.5 ±253.1 μm and 197.3 ±54.8 μm for LD (P=.03) and 360 ±62.9 μm and 152.8 ±44.8 μm for BioHPP (P=.04). The mean ±standard deviation of internal space volume was 15.3 ±11.8 μm³ for LD and 24.1 ±10.7 μm³ for BioHPP (P=.08). The mean ±standard deviation of fracture strength was 2509.8 ±680 N for BioHPP and 1090.4 ±454.2 MPa for LD groups (P<.05). CONCLUSIONS The marginal adaptation of pressed lithium disilicate crowns was better, while BioHPP crowns displayed greater fracture strength. Marginal gap width was not correlated with fracture strength in either group.
Collapse
Affiliation(s)
- Mahnaz Arshad
- Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran, Associate Professor, Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran
| | - Sahar Hassantash
- Graduate student, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Shamim Chinian
- Graduate student, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Sadr
- Professor, Biomimetics Biomaterials Biophotonics Biomechanics & Technology Laboratory, Department of Restorative Dentistry, University of Washington, Seattle, Wash
| | - Sareh Habibzadeh
- Associate Professor, Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran, Associate Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
24
|
Hata K, Komagata Y, Nagamatsu Y, Masaki C, Hosokawa R, Ikeda H. Bond Strength of Sandblasted PEEK with Dental Methyl Methacrylate-Based Cement or Composite-Based Resin Cement. Polymers (Basel) 2023; 15:polym15081830. [PMID: 37111977 PMCID: PMC10145247 DOI: 10.3390/polym15081830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/07/2023] [Accepted: 04/08/2023] [Indexed: 04/29/2023] Open
Abstract
Poly-ether-ether-ketone (PEEK) is commonly employed in dental prostheses owing to its excellent mechanical properties; however, it is limited by its low bond strength with dental resin cement. This study aimed to clarify the type of resin cement most suitable for bonding to PEEK: methyl methacrylate (MMA)-based resin cement or composite-based resin cement. For this purpose, two MMA-based resin cements (Super-Bond EX and MULTIBOND II) and five composite-based resin cements (Block HC Cem, RelyX Universal Resin Cement, G-CEM LinkForce, Panavia V5, and Multilink Automix) were used in combination with appropriate adhesive primers. A PEEK block (SHOFU PEEK) was initially cut, polished, and sandblasted with alumina. The sandblasted PEEK was then bonded to resin cement with adhesive primer according to the manufacturer's instructions. The resulting specimens were immersed in water at 37 °C for 24 h, followed by thermocycling. Subsequently, the tensile bond strengths (TBSs) of the specimens were measured; the TBSs of the composite-based resin cements after thermocycling were found to be zero (G-CEM LinkForce, Panavia V5, and Multilink Automix), 0.03 ± 0.04 (RelyX Universal Resin Cement), or 1.6 ± 2.7 (Block HC Cem), whereas those of Super-Bond and MULTIBOND were 11.9 ± 2.6 and 4.8 ± 2.3 MPa, respectively. The results demonstrated that MMA-based resin cements exhibited stronger bonding to PEEK than composite-based resin cements.
Collapse
Affiliation(s)
- Kentaro Hata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Yuya Komagata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| |
Collapse
|
25
|
Luo C, Liu Y, Peng B, Chen M, Liu Z, Li Z, Kuang H, Gong B, Li Z, Sun H. PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers (Basel) 2023; 15:386. [PMID: 36679266 PMCID: PMC9864167 DOI: 10.3390/polym15020386] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/06/2023] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared to traditional metal and ceramic dental materials, PEEK dental implants exhibit less stress shielding, thus better matching the mechanical properties of bone. As a promising medical material, PEEK can be used as implant abutments, removable and fixed prostheses, and maxillofacial prostheses. It can be blended with materials such as fibers and ceramics to improve its mechanical strength for better clinical dental applications. Compared to conventional pressed and CAD/CAM milling fabrication, 3D-printed PEEK exhibits excellent flexural and tensile strength and parameters such as printing temperature and speed can affect its mechanical properties. However, the bioinert nature of PEEK can make adhesive bonding difficult. The bond strength can be improved by roughening or introducing functional groups on the PEEK surface by sandblasting, acid etching, plasma treatment, laser treatment, and adhesive systems. This paper provides a comprehensive overview of the research progress on the mechanical properties of PEEK for dental applications in the context of specific applications, composites, and their preparation processes. In addition, the research on the adhesive properties of PEEK over the past few years is highlighted. Thus, this review aims to build a conceptual and practical toolkit for the study of the mechanical and adhesive properties of PEEK materials. More importantly, it provides a rationale and a general new basis for the application of PEEK in the dental field.
Collapse
Affiliation(s)
- Chengfeng Luo
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Ying Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian 271000, China
| | - Bo Peng
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Menghao Chen
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Zhaogang Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian 271000, China
| | - Zhanglong Li
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Hai Kuang
- Department of Oral and Maxillofacial Surgery, College of Stomatology, Guangxi Medical University, Nanning 530021, China
- Key Laboratory of Research and Application of Stomatological Equipment (College of Stomatology, Guangxi Medical University), Education Department of Guangxi Zhuang Autonomous Region, Nanning 530021, China
| | - Baijuan Gong
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Zhimin Li
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Hongchen Sun
- Hospital of Stomatology, Jilin University, Changchun 130021, China
| |
Collapse
|
26
|
Pidhatika B, Widyaya VT, Nalam PC, Swasono YA, Ardhani R. Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry. Polymers (Basel) 2022; 14:polym14245526. [PMID: 36559893 PMCID: PMC9787615 DOI: 10.3390/polym14245526] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 12/23/2022] Open
Abstract
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium-the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Collapse
Affiliation(s)
- Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
- Collaborative Research Center for Biomedical Scaffolds, National Research and Innovation Agency of the Republic Indonesia and Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
| | - Vania Tanda Widyaya
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Prathima C. Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY 14260-1900, USA
| | - Yogi Angga Swasono
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
- Correspondence:
| |
Collapse
|
27
|
Strategies for Improved Wettability of Polyetheretherketone (PEEK) Polymers by Non-Equilibrium Plasma Treatment. Polymers (Basel) 2022; 14:polym14235319. [PMID: 36501716 PMCID: PMC9739015 DOI: 10.3390/polym14235319] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/25/2022] [Accepted: 11/29/2022] [Indexed: 12/12/2022] Open
Abstract
Polyetheretherketone (PEEK) is the material of choice in several applications ranging from the automotive industry to medicine, but the surface properties are usually not adequate. A standard method for tailoring surface properties is the application of gaseous plasma. The surface finish depends enormously on the processing parameters. This article presents a review of strategies adapted for improved wettability and adhesion of PEEK. The kinetics of positively charged ions, neutral reactive plasma species, and vacuum ultraviolet radiation on the surface finish are analyzed, and synergies are stressed where appropriate. The reviewed articles are critically assessed regarding the plasma and surface kinetics, and the surface mechanisms are illustrated. The directions for obtaining optimal surface finish are provided together with the scientific explanation of the limitations of various approaches. Super-hydrophilic surface finish is achievable by treatment with a large dose of vacuum ultraviolet radiation in the presence of oxidizing gas. Bombardment with positively charged ions of kinetic energy between about 100 and 1000 eV also enable high wettability, but one should be aware of excessive heating when using the ions.
Collapse
|
28
|
Wang X, Liu W, Yu X, Wang B, Xu Y, Yan X, Zhang X. Advances in surface modification of tantalum and porous tantalum for rapid osseointegration: A thematic review. Front Bioeng Biotechnol 2022; 10:983695. [PMID: 36177183 PMCID: PMC9513364 DOI: 10.3389/fbioe.2022.983695] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 08/15/2022] [Indexed: 11/30/2022] Open
Abstract
After bone defects reach a certain size, the body can no longer repair them. Tantalum, including its porous form, has attracted increasing attention due to good bioactivity, biocompatibility, and biomechanical properties. After a metal material is implanted into the body as a medical intervention, a series of interactions occurs between the material’s surface and the microenvironment. The interaction between cells and the surface of the implant mainly depends on the surface morphology and chemical composition of the implant’s surface. In this context, appropriate modification of the surface of tantalum can guide the biological behavior of cells, promote the potential of materials, and facilitate bone integration. Substantial progress has been made in tantalum surface modification technologies, especially nano-modification technology. This paper systematically reviews the progress in research on tantalum surface modification for the first time, including physicochemical properties, biological performance, and surface modification technologies of tantalum and porous tantalum.
Collapse
Affiliation(s)
- Xi Wang
- Department of Emergency and Oral Medicine, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Wentao Liu
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Xinding Yu
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Biyao Wang
- The VIP Department, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Yan Xu
- The Comprehensive Department of Shenyang Stomatological Hospital, Shenyang, China
| | - Xu Yan
- The VIP Department, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
- *Correspondence: Xu Yan, ; Xinwen Zhang,
| | - Xinwen Zhang
- Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
- *Correspondence: Xu Yan, ; Xinwen Zhang,
| |
Collapse
|