1
|
Zhang S, Staples AE. Microfluidic-based systems for the management of diabetes. Drug Deliv Transl Res 2024:10.1007/s13346-024-01569-y. [PMID: 38509342 DOI: 10.1007/s13346-024-01569-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/04/2024] [Indexed: 03/22/2024]
Abstract
Diabetes currently affects approximately 500 million people worldwide and is one of the most common causes of mortality in the United States. To diagnose and monitor diabetes, finger-prick blood glucose testing has long been used as the clinical gold standard. For diabetes treatment, insulin is typically delivered subcutaneously through cannula-based syringes, pens, or pumps in almost all type 1 diabetic (T1D) patients and some type 2 diabetic (T2D) patients. These painful, invasive approaches can cause non-adherence to glucose testing and insulin therapy. To address these problems, researchers have developed miniaturized blood glucose testing devices as well as microfluidic platforms for non-invasive glucose testing through other body fluids. In addition, glycated hemoglobin (HbA1c), insulin levels, and cellular biomechanics-related metrics have also been considered for microfluidic-based diabetes diagnosis. For the treatment of diabetes, insulin has been delivered transdermally through microdevices, mostly through microneedle array-based, minimally invasive injections. Researchers have also developed microfluidic platforms for oral, intraperitoneal, and inhalation-based delivery of insulin. For T2D patients, metformin, glucagon-like peptide 1 (GLP-1), and GLP-1 receptor agonists have also been delivered using microfluidic technologies. Thus far, clinical studies have been widely performed on microfluidic-based diabetes monitoring, especially glucose sensing, yet technologies for the delivery of insulin and other drugs to diabetic patients with microfluidics are still mostly in the preclinical stage. This article provides a concise review of the role of microfluidic devices in the diagnosis and monitoring of diabetes, as well as the delivery of pharmaceuticals to treat diabetes using microfluidic technologies in the recent literature.
Collapse
Affiliation(s)
- Shuyu Zhang
- Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, 24061, USA.
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, 24061, USA.
| | - Anne E Staples
- Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, VA, 24061, USA
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
2
|
Brazaca LC, Imamura AH, Blasques RV, Camargo JR, Janegitz BC, Carrilho E. The use of biological fluids in microfluidic paper-based analytical devices (μPADs): Recent advances, challenges and future perspectives. Biosens Bioelectron 2024; 246:115846. [PMID: 38006702 DOI: 10.1016/j.bios.2023.115846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 11/10/2023] [Accepted: 11/14/2023] [Indexed: 11/27/2023]
Abstract
The use of microfluidic paper-based analytical devices (μPADs) for aiding medical diagnosis is a growing trend in the literature mainly due to their low cost, easy use, simple manufacturing, and great potential for application in low-resource settings. Many important biomarkers (proteins, ions, lipids, hormones, DNA, RNA, drugs, whole cells, and more) and biofluids are available for precise detection and diagnosis. We have reviewed the advances μPADs in medical diagnostics have achieved in the last few years, focusing on the most common human biofluids (whole blood/plasma, sweat, urine, tears, and saliva). The challenges of detecting specific biomarkers in each sample are discussed, along with innovative techniques that overcome such limitations. Finally, the difficulties of commercializing μPADs are considered, and future trends are presented, including wearable devices and integrating multiple steps in a single platform.
Collapse
Affiliation(s)
- Laís Canniatti Brazaca
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil.
| | - Amanda Hikari Imamura
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil
| | - Rodrigo Vieira Blasques
- Departamento de Ciências da Natureza, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil
| | - Jéssica Rocha Camargo
- Departamento de Ciências da Natureza, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil
| | - Bruno Campos Janegitz
- Departamento de Ciências da Natureza, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil
| |
Collapse
|
3
|
Musile G, Grazioli C, Fornasaro S, Dossi N, De Palo EF, Tagliaro F, Bortolotti F. Application of Paper-Based Microfluidic Analytical Devices (µPAD) in Forensic and Clinical Toxicology: A Review. BIOSENSORS 2023; 13:743. [PMID: 37504142 PMCID: PMC10377625 DOI: 10.3390/bios13070743] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/14/2023] [Accepted: 06/23/2023] [Indexed: 07/29/2023]
Abstract
The need for providing rapid and, possibly, on-the-spot analytical results in the case of intoxication has prompted researchers to develop rapid, sensitive, and cost-effective methods and analytical devices suitable for use in nonspecialized laboratories and at the point of need (PON). In recent years, the technology of paper-based microfluidic analytical devices (μPADs) has undergone rapid development and now provides a feasible, low-cost alternative to traditional rapid tests for detecting harmful compounds. In fact, µPADs have been developed to detect toxic molecules (arsenic, cyanide, ethanol, and nitrite), drugs, and drugs of abuse (benzodiazepines, cathinones, cocaine, fentanyl, ketamine, MDMA, morphine, synthetic cannabinoids, tetrahydrocannabinol, and xylazine), and also psychoactive substances used for drug-facilitated crimes (flunitrazepam, gamma-hydroxybutyric acid (GHB), ketamine, metamizole, midazolam, and scopolamine). The present report critically evaluates the recent developments in paper-based devices, particularly in detection methods, and how these new analytical tools have been tested in forensic and clinical toxicology, also including future perspectives on their application, such as multisensing paper-based devices, microfluidic paper-based separation, and wearable paper-based sensors.
Collapse
Affiliation(s)
- Giacomo Musile
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Cristian Grazioli
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Stefano Fornasaro
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgeri 1, 34127 Trieste, Italy
| | - Nicolò Dossi
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Elio Franco De Palo
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Franco Tagliaro
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
- Laboratory of Pharmacokinetics and Metabolomics Analysis, Institute of Translational Medicine and Biotechnology, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street, 119991 Moscow, Russia
| | - Federica Bortolotti
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| |
Collapse
|
4
|
Inagawa A, Iimura KI, Uehara N. Fabrication of paper-based analytical devices by a laminating method with thermal ink ribbons, sticky notes, and office appliances. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:537-542. [PMID: 36645123 DOI: 10.1039/d2ay01981g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
A stencil printing method utilizing sticky notes, a thermal transfer ink ribbon, and office appliances for paper-based analytical device (PAD) fabrication was proposed. A sticky note was attached to a filter paper, and a mask pattern was cut using a cutting machine. A commercially available thermal ink ribbon was then placed over the mask and laminated. We have characterized the fabricated devices. This approach could be used for the fast and mass prototyping of PADs using simple office appliances with no need for a wax printer.
Collapse
Affiliation(s)
- Arinori Inagawa
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi, 321-8585 Japan.
| | - Ken-Ichi Iimura
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi, 321-8585 Japan.
| | - Nobuo Uehara
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi, 321-8585 Japan.
| |
Collapse
|
5
|
Silva-Neto HA, Arantes IV, Ferreira AL, do Nascimento GH, Meloni GN, de Araujo WR, Paixão TR, Coltro WK. Recent advances on paper-based microfluidic devices for bioanalysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
6
|
Wang J, Yang T, Li Z, Zhou K, Xiao B, Yu P. Semi-quantitative analysis of nickel: counting-based μPADs built via hand drawing and yellow oily double-sided adhesive tape. RSC Adv 2022; 12:30457-30465. [PMCID: PMC9598315 DOI: 10.1039/d2ra03892g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 10/11/2022] [Indexed: 11/06/2022] Open
Abstract
Counting-based μPADs were fabricated by hand drawing and yellow oily double-sided adhesive tape, and then successfully applied for the semi-quantitative analysis of nickel.
Collapse
Affiliation(s)
- Jian Wang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Tong Yang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Zhengjia Li
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Kecen Zhou
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Bo Xiao
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Peng Yu
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| |
Collapse
|
7
|
Tai WC, Chang YC, Chou D, Fu LM. Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review. BIOSENSORS 2021; 11:260. [PMID: 34436062 PMCID: PMC8393526 DOI: 10.3390/bios11080260] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/26/2021] [Accepted: 07/29/2021] [Indexed: 12/23/2022]
Abstract
In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.
Collapse
Affiliation(s)
- Wei-Chun Tai
- Department of Oral and Maxillofacial Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan;
| | - Yu-Chi Chang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
| | - Dean Chou
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
- Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
| |
Collapse
|
8
|
Zhiyue M, Xichen Y, Li R, Yang Y, Huicheng F, Peng S. Recent advances in paper-based preconcentrators by utilizing ion concentration polarization. Electrophoresis 2021; 42:1340-1351. [PMID: 33768593 DOI: 10.1002/elps.202000291] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/26/2021] [Accepted: 03/15/2021] [Indexed: 11/09/2022]
Abstract
One of the most cited limitations of biochemical detection is its poor sensitivity, owing to the relatively high complexity of micro-samples. Moreover, some samples cannot be easily self-replicated and their abundance cannot be increased through traditional technologies. Therefore, the preconcentration of low-abundance samples is a key requirement for microfluidic biological analysis. In recent years, the ion-concentration polarization phenomenon has aroused widespread interest in the application of microfluidic technology. In addition, paper-based materials are readily available, easy to modify, and exhibit good hydrophilicity. The study of the ion-concentration polarization preconcentration of micro-samples in paper-based microfluidic chips is of considerable significance. In this review, we discuss the development and applications of ion-concentration polarization paper-based preconcentrator in the past 5 years, with emphasis on key progresses in chip fabrication and performance optimization under different conditions. The current needs and development prospects in this field have also been discussed.
Collapse
Affiliation(s)
- Meng Zhiyue
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yuan Xichen
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China.,Yangtze River Delta Research Institute of Northwestern Polytechnical University, Taicang, P. R. China
| | - Ren Li
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yang Yang
- Ministry of Education Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, Chongqing, P. R. China
| | - Feng Huicheng
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi'an, P. R. China.,MOE Key Laboratory of Micro and Nano Systems for Aerospace, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Shang Peng
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| |
Collapse
|
9
|
De Matteis V, Cascione M, Fella G, Mazzotta L, Rinaldi R. Colorimetric Paper-Based Device for Hazardous Compounds Detection in Air and Water: A Proof of Concept. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5502. [PMID: 32992867 PMCID: PMC7582469 DOI: 10.3390/s20195502] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 09/11/2020] [Accepted: 09/23/2020] [Indexed: 11/30/2022]
Abstract
In the last decades, the increase in global industrialization and the consequent technological progress have damaged the quality of the environment. As a consequence, the high levels of hazardous compounds such as metals and gases released in the atmosphere and water, have raised several concerns about the health of living organisms. Today, many analytical techniques are available with the aim to detect pollutant chemical species. However, a lot of them are not affordable due to the expensive instrumentations, time-consuming processes and high reagents volumes. Last but not least, their use is exclusive to trained operators. Contrarily, colorimetric sensing devices, including paper-based devices, are easy to use, providing results in a short time, without particular specializations to interpret the results. In addition, the colorimetric response is suitable for fast detection, especially in resource-limited environments or underdeveloped countries. Among different chemical species, transition and heavy metals such as iron Fe(II) and copper Cu(II) as well as volatile compounds, such as ammonia (NH3) and acetaldehyde (C2H4O) are widespread mainly in industrialized geographical areas. In this work, we developed a colorimetric paper-based analytical device (PAD) to detect different contaminants, including Fe2+ and Cu2+ ions in water, and NH3 and C2H4O in air at low concentrations. This study is a "proof of concept" of a new paper sensor in which the intensity of the colorimetric response is proportional to the concentration of a detected pollutant species. The sensor model could be further implemented in other technologies, such as drones, individual protection devices or wearable apparatus to monitor the exposure to toxic species in both indoor and outdoor environments.
Collapse
Affiliation(s)
- Valeria De Matteis
- Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce, Italy; (M.C.); (G.F.); (R.R.)
| | - Mariafrancesca Cascione
- Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce, Italy; (M.C.); (G.F.); (R.R.)
| | - Gabriele Fella
- Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce, Italy; (M.C.); (G.F.); (R.R.)
| | - Laura Mazzotta
- Studio Effemme-Chimica Applicata, Via Paolo VI, 73018 Squinzano (LE), Italy;
| | - Rosaria Rinaldi
- Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce, Italy; (M.C.); (G.F.); (R.R.)
| |
Collapse
|
10
|
3D Microfluidic Devices in a Single Piece of Paper for the Simultaneous Determination of Nitrite and Thiocyanate. SENSORS 2020; 20:s20154118. [PMID: 32722091 PMCID: PMC7435404 DOI: 10.3390/s20154118] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 07/18/2020] [Accepted: 07/22/2020] [Indexed: 02/07/2023]
Abstract
The concentrations of nitrite and thiocyanate in saliva can be used as the biomarkers of the progression of periodontitis disease and environmental tobacco smoke exposure, respectively. Therefore, it is particularly necessary to detect these two indicators in saliva. Herein, the three-dimensional single-layered paper-based microfluidic analytical devices (3D sl-μPADs) were, for the first time, fabricated by the spraying technique for the colorimetric detection of nitrite and thiocyanate at the same time. The conditions for 3D sl-μPADs fabrication were optimized in order to well control the penetration depth of the lacquer in a paper substrate. Then, the developed 3D sl-μPADs were utilized to simultaneously detect nitrite and thiocyanate and the limits of detection are 0.0096 and 0.074 mM, respectively. What is more, the μPADs exhibited good specificity, good repeatability, and acceptable recoveries in artificial saliva. Therefore, the developed 3D sl-μPADs show a great potential to determine nitrite and thiocyanate for the assessment of the human health.
Collapse
|