Choi H, Biswas S, Lang P, Bae JH, Kim H. A Current Development of Energy Harvesting Systems for Energy-Independent Bioimplantable Biosensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2403899. [PMID: 38984756 DOI: 10.1002/smll.202403899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 06/18/2024] [Indexed: 07/11/2024]
Abstract
Biosensors have emerged as vital tools for the detection and monitoring of essential biological information. However, their efficiency is often constrained by limitations in the power supply. To address this challenge, energy harvesting systems have gained prominence. These off-grid, independent systems harness energy from the surrounding environment, providing a sustainable solution for powering biosensors autonomously. This continuous power source overcomes critical constraints, ensuring uninterrupted operation and seamless data collection. In this article, a comprehensive review of recent literature on energy harvesting-based biosensors is presented. Various techniques and technologies are critically examined, including optical, mechanical, thermal, and wireless power transfer, focusing on their applications and optimization. Furthermore, the immense potential of these energy harvesting-driven biosensors is highlighted across diverse fields, such as medicine, environmental surveillance, and biosignal analysis. By exploring the integration of energy harvesting systems, this review underscores their pivotal role in advancing biosensor technology. These innovations promise improved efficiency, reduced environmental impact, and broader applicability, marking significant progress in the field of biosensors.
Collapse
Affiliation(s)
- Hyojeong Choi
- School of Electrical and Computer Engineering, Center for Smart Sensor System of Seoul (CS4), University of Seoul, 163 Seoulsiripdaero, Dongdaemun-gu, Seoul, 02504, Republic of Korea
| | - Swarup Biswas
- School of Electrical and Computer Engineering, Center for Smart Sensor System of Seoul (CS4), University of Seoul, 163 Seoulsiripdaero, Dongdaemun-gu, Seoul, 02504, Republic of Korea
| | - Philippe Lang
- ITODYS, University of Paris, CNRS UMR 7086, 15 rue Jean-Antoine de Baif, Paris CEDEX 13, 75205, France
| | - Jin-Hyuk Bae
- School of Electronic and Electrical Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| | - Hyeok Kim
- School of Electrical and Computer Engineering, Center for Smart Sensor System of Seoul (CS4), University of Seoul, 163 Seoulsiripdaero, Dongdaemun-gu, Seoul, 02504, Republic of Korea
| |
Collapse
|
2
|
Imani IM, Kim HS, Shin J, Lee DG, Park J, Vaidya A, Kim C, Baik JM, Zhang YS, Kang H, Hur S, Song HC. Advanced Ultrasound Energy Transfer Technologies using Metamaterial Structures. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2401494. [PMID: 38889336 DOI: 10.1002/advs.202401494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 04/05/2024] [Indexed: 06/20/2024]
Abstract
Wireless energy transfer (WET) based on ultrasound-driven generators with enormous beneficial functions, is technologically in progress by the valuation of ultrasonic metamaterials (UMMs) in science and engineering domains. Indeed, novel metamaterial structures can develop the efficiency of mechanical and physical features of ultrasound energy receivers (US-ETs), including ultrasound-driven piezoelectric and triboelectric nanogenerators (US-PENGs and US-TENGs) for advantageous applications. This review article first summarizes the fundamentals, classification, and design engineering of UMMs after introducing ultrasound energy for WET technology. In addition to addressing using UMMs, the topical progress of innovative UMMs in US-ETs is conceptually presented. Moreover, the advanced approaches of metamaterials are reported in the categorized applications of US-PENGs and US-TENGs. Finally, some current perspectives and encounters of UMMs in US-ETs are offered. With this objective in mind, this review explores the potential revolution of reliable integrated energy transfer systems through the transformation of metamaterials into ultrasound-driven active mediums for generators.
Collapse
Affiliation(s)
- Iman M Imani
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Hyun Soo Kim
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Joonchul Shin
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Dong-Gyu Lee
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
- Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Jiwon Park
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Anish Vaidya
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Chowon Kim
- Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Jeong Min Baik
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
- KIST-SKKU Carbon-Neutral Research Center, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Yu Shrike Zhang
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital Harvard Medical School, Cambridge, MA, 02139, USA
| | - Heemin Kang
- Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Sunghoon Hur
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
- KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul, 02447, Republic of Korea
| | - Hyun-Cheol Song
- Electronic Materials Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
- KIST-SKKU Carbon-Neutral Research Center, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| |
Collapse
|
3
|
Sirolli S, Guarnera D, Ricotti L, Cafarelli A. Triggerable Patches for Medical Applications. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2310110. [PMID: 38860756 DOI: 10.1002/adma.202310110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 06/05/2024] [Indexed: 06/12/2024]
Abstract
Medical patches have garnered increasing attention in recent decades for several diagnostic and therapeutic applications. Advancements in material science, manufacturing technologies, and bioengineering have significantly widened their functionalities, rendering them highly versatile platforms for wearable and implantable applications. Of particular interest are triggerable patches designed for drug delivery and tissue regeneration purposes, whose action can be controlled by an external signal. Stimuli-responsive patches are particularly appealing as they may enable a high level of temporal and spatial control over the therapy, allowing high therapeutic precision and the possibility to adjust the treatment according to specific clinical and personal needs. This review aims to provide a comprehensive overview of the existing extensive literature on triggerable patches, emphasizing their potential for diverse applications and highlighting the strengths and weaknesses of different triggering stimuli. Additionally, the current open challenges related to the design and use of efficient triggerable patches, such as tuning their mechanical and adhesive properties, ensuring an acceptable trade-off between smartness and biocompatibility, endowing them with portability and autonomy, accurately controlling their responsiveness to the triggering stimulus and maximizing their therapeutic efficacy, are reviewed.
Collapse
Affiliation(s)
- Sofia Sirolli
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| | - Daniele Guarnera
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| | - Leonardo Ricotti
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| | - Andrea Cafarelli
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| |
Collapse
|
4
|
De Ridder D, Siddiqi MA, Dauwels J, Serdijn WA, Strydis C. NeuroDots: From Single-Target to Brain-Network Modulation: Why and What Is Needed? Neuromodulation 2024; 27:711-729. [PMID: 38639704 DOI: 10.1016/j.neurom.2024.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 11/05/2023] [Accepted: 01/10/2024] [Indexed: 04/20/2024]
Abstract
OBJECTIVES Current techniques in brain stimulation are still largely based on a phrenologic approach that a single brain target can treat a brain disorder. Nevertheless, meta-analyses of brain implants indicate an overall success rate of 50% improvement in 50% of patients, irrespective of the brain-related disorder. Thus, there is still a large margin for improvement. The goal of this manuscript is to 1) develop a general theoretical framework of brain functioning that is amenable to surgical neuromodulation, and 2) describe the engineering requirements of the next generation of implantable brain stimulators that follow from this theoretic model. MATERIALS AND METHODS A neuroscience and engineering literature review was performed to develop a universal theoretical model of brain functioning and dysfunctioning amenable to surgical neuromodulation. RESULTS Even though a single target can modulate an entire network, research in network science reveals that many brain disorders are the consequence of maladaptive interactions among multiple networks rather than a single network. Consequently, targeting the main connector hubs of those multiple interacting networks involved in a brain disorder is theoretically more beneficial. We, thus, envision next-generation network implants that will rely on distributed, multisite neuromodulation targeting correlated and anticorrelated interacting brain networks, juxtaposing alternative implant configurations, and finally providing solid recommendations for the realization of such implants. In doing so, this study pinpoints the potential shortcomings of other similar efforts in the field, which somehow fall short of the requirements. CONCLUSION The concept of network stimulation holds great promise as a universal approach for treating neurologic and psychiatric disorders.
Collapse
Affiliation(s)
- Dirk De Ridder
- Section of Neurosurgery, Department of Surgical Sciences, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand.
| | - Muhammad Ali Siddiqi
- Department of Electrical Engineering, Lahore University of Management Sciences, Lahore, Pakistan; Neuroscience Department, Erasmus Medical Center, Rotterdam, The Netherlands; Quantum and Computer Engineering Department, Delft University of Technology, Delft, The Netherlands
| | - Justin Dauwels
- Microelectronics Department, Delft University of Technology, Delft, The Netherlands
| | - Wouter A Serdijn
- Neuroscience Department, Erasmus Medical Center, Rotterdam, The Netherlands; Section Bioelectronics, Delft University of Technology, Delft, The Netherlands
| | - Christos Strydis
- Neuroscience Department, Erasmus Medical Center, Rotterdam, The Netherlands; Quantum and Computer Engineering Department, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
5
|
Xu Z, Rodriguez-Villegas E. A Wireless Power Transfer Mattress Based System for Perpetually Operating Physiological Monitoring Wearables. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:460-473. [PMID: 38039174 DOI: 10.1109/tbcas.2023.3338541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
This article presents a novel wireless power mattress-based system architecture tailored to guarantee continuous energy for in-home environment healthcare wearables intended to be used in the context of patients who would benefit from long-term monitoring of specific physiological biomarkers. The design demonstrates that it is possible to transfer over 20 mW at a primary-secondary distance of 20.7 cm, whilst still keeping within all FCC/ICNIRP safety regulations, using the proposed simplified beamforming-controlled power transfer multi-input single-output system. Compared with other beamforming-controlled based works, the proposed design used non-coupling coil arrays, significantly reducing the algorithmic complexity. An on-chip wireless power charger system was also designed to provide high-efficiency power storage (89.3% power conversion efficiency and 83.9% power charge efficiency), guaranteeing wearables can continuously maintain their functionality. In contrast with conventional NiMh chargers, this work proposes a trimming function that makes it compatible with batteries of varying capacities. It also employs a four-stage charge loop to ensure safety and sustainability during the charging process. Overall, this work shows that by relying on wireless power transfer, it is, in principle, possible to create a safe wearable that could enable continuous monitoring of certain healthcare biomarkers with little or zero maintenance burden for the patients or carers.
Collapse
|
6
|
Mukherjee D, Rainu SK, Singh N, Mallick D. A Miniaturized, Low-Frequency Magnetoelectric Wireless Power Transfer System for Powering Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:438-450. [PMID: 37999967 DOI: 10.1109/tbcas.2023.3336598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2023]
Abstract
This work experimentally demonstrates the operation of a miniaturized magnetoelectric (ME) wireless power transfer (WPT) system by incorporating a ME transducer and a suitable interface power management circuit (PMC) for potentially powering implantable medical devices (IMD) wirelessly. A ME heterostructure is micromachined to obtain desired device dimensions of 3.5 × 5 mm 2 and to restrict the operating frequency at a clinically approved frequency of 50 kHz. The proposed work also aims to address the trade-off between the device miniaturization, power attenuation and limiting the specific absorption rate (SAR) in the human tissue. By limiting the operating frequency to 50 kHz, the SAR is reduced to less than 1 μW/kg. The fabricated device is characterized with low-intensity AC magnetic field up to 40 μT without using any DC bias, resulting in 0.4 V output voltage and 6.6 μW power across 8 k Ω load. Alignment misorientation between the Tx and Rx is studied for in-plane and out-of-plane angular rotations to confirm the device's reliability against angular misalignment. By eliminating the bulky biasing magnets, the proposed device achieves a significant size reduction compared to the previously reported works. In addition, a self-powered interface PMC is incorporated with the ME system. The PMC generates 3.5 V regulated DC voltage from the input AC voltage range 0.7 V to 3.3 V. The PMC is fabricated on a 2-layered PCB and the over all ME WPT system consumes 12 × 12 mm 2 area. The overall PMC has intrinsic current consumption less than 550 nA with peak power conversion efficiency higher than 85 %. The in vitro cytotoxicity analysis in the human hepatic cell line WRL-68 confirmed the biocompatibility of the Parylene-C encapsulated ME device for up to 7 days, suggesting its potential use in implantable electronic devices for biomedical and clinical applications.
Collapse
|
7
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
8
|
Yue O, Wang X, Xie L, Bai Z, Zou X, Liu X. Biomimetic Exogenous "Tissue Batteries" as Artificial Power Sources for Implantable Bioelectronic Devices Manufacturing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307369. [PMID: 38196276 PMCID: PMC10953594 DOI: 10.1002/advs.202307369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/27/2023] [Indexed: 01/11/2024]
Abstract
Implantable bioelectronic devices (IBDs) have gained attention for their capacity to conformably detect physiological and pathological signals and further provide internal therapy. However, traditional power sources integrated into these IBDs possess intricate limitations such as bulkiness, rigidity, and biotoxicity. Recently, artificial "tissue batteries" (ATBs) have diffusely developed as artificial power sources for IBDs manufacturing, enabling comprehensive biological-activity monitoring, diagnosis, and therapy. ATBs are on-demand and designed to accommodate the soft and confining curved placement space of organisms, minimizing interface discrepancies, and providing ample power for clinical applications. This review presents the near-term advancements in ATBs, with a focus on their miniaturization, flexibility, biodegradability, and power density. Furthermore, it delves into material-screening, structural-design, and energy density across three distinct categories of TBs, distinguished by power supply strategies. These types encompass innovative energy storage devices (chemical batteries and supercapacitors), power conversion devices that harness power from human-body (biofuel cells, thermoelectric nanogenerators, bio-potential devices, piezoelectric harvesters, and triboelectric devices), and energy transfer devices that receive and utilize external energy (radiofrequency-ultrasound energy harvesters, ultrasound-induced energy harvesters, and photovoltaic devices). Ultimately, future challenges and prospects emphasize ATBs with the indispensability of bio-safety, flexibility, and high-volume energy density as crucial components in long-term implantable bioelectronic devices.
Collapse
Affiliation(s)
- Ouyang Yue
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xuechuan Wang
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Long Xie
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Zhongxue Bai
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xiaoliang Zou
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xinhua Liu
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| |
Collapse
|
9
|
Miziev S, Pawlak WA, Howard N. Comparative analysis of energy transfer mechanisms for neural implants. Front Neurosci 2024; 17:1320441. [PMID: 38292898 PMCID: PMC10825050 DOI: 10.3389/fnins.2023.1320441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 12/19/2023] [Indexed: 02/01/2024] Open
Abstract
As neural implant technologies advance rapidly, a nuanced understanding of their powering mechanisms becomes indispensable, especially given the long-term biocompatibility risks like oxidative stress and inflammation, which can be aggravated by recurrent surgeries, including battery replacements. This review delves into a comprehensive analysis, starting with biocompatibility considerations for both energy storage units and transfer methods. The review focuses on four main mechanisms for powering neural implants: Electromagnetic, Acoustic, Optical, and Direct Connection to the Body. Among these, Electromagnetic Methods include techniques such as Near-Field Communication (RF). Acoustic methods using high-frequency ultrasound offer advantages in power transmission efficiency and multi-node interrogation capabilities. Optical methods, although still in early development, show promising energy transmission efficiencies using Near-Infrared (NIR) light while avoiding electromagnetic interference. Direct connections, while efficient, pose substantial safety risks, including infection and micromotion disturbances within neural tissue. The review employs key metrics such as specific absorption rate (SAR) and energy transfer efficiency for a nuanced evaluation of these methods. It also discusses recent innovations like the Sectored-Multi Ring Ultrasonic Transducer (S-MRUT), Stentrode, and Neural Dust. Ultimately, this review aims to help researchers, clinicians, and engineers better understand the challenges of and potentially create new solutions for powering neural implants.
Collapse
|
10
|
Wang S, Cui Q, Abiri P, Roustaei M, Zhu E, Li YR, Wang K, Duarte S, Yang L, Ebrahimi R, Bersohn M, Chen J, Hsiai TK. A self-assembled implantable microtubular pacemaker for wireless cardiac electrotherapy. SCIENCE ADVANCES 2023; 9:eadj0540. [PMID: 37851816 PMCID: PMC10584332 DOI: 10.1126/sciadv.adj0540] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 09/15/2023] [Indexed: 10/20/2023]
Abstract
The current cardiac pacemakers are battery dependent, and the pacing leads are prone to introduce valve damage and infection, plus a complete pacemaker retrieval is needed for battery replacement. Despite the reported wireless bioelectronics to pace the epicardium, open-chest surgery (thoracotomy) is required to implant the device, and the procedure is invasive, requiring prolonged wound healing and health care burden. We hereby demonstrate a fully biocompatible wireless microelectronics with a self-assembled design that can be rolled into a lightweight microtubular pacemaker for intravascular implantation and pacing. The radio frequency was used to transfer energy to the microtubular pacemaker for electrical stimulation. We show that this pacemaker provides effective pacing to restore cardiac contraction from a nonbeating heart and have the capacity to perform overdrive pacing to augment blood circulation in an anesthetized pig model. Thus, this microtubular pacemaker paves the way for the minimally invasive implantation of leadless and battery-free microelectronics.
Collapse
Affiliation(s)
- Shaolei Wang
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Qingyu Cui
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Parinaz Abiri
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Mehrdad Roustaei
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Enbo Zhu
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
- Department of Microbiology, Immunology and Molecular Genetics, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Yan-Ruide Li
- Department of Microbiology, Immunology and Molecular Genetics, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Kaidong Wang
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
- Department of Medicine, Great Los Angeles VA Healthcare System, Los Angeles, CA 90073, USA
| | - Sandra Duarte
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Lili Yang
- Department of Microbiology, Immunology and Molecular Genetics, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Ramin Ebrahimi
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Department of Medicine, Great Los Angeles VA Healthcare System, Los Angeles, CA 90073, USA
| | - Malcolm Bersohn
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Department of Medicine, Great Los Angeles VA Healthcare System, Los Angeles, CA 90073, USA
| | - Jun Chen
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
| | - Tzung K. Hsiai
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA 90095, USA
- Division of Cardiology, Department of Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA
- Department of Medicine, Great Los Angeles VA Healthcare System, Los Angeles, CA 90073, USA
| |
Collapse
|
11
|
Van de Steene T, Tanghe E, Martens L, Garripoli C, Stanzione S, Joseph W. Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People. SENSORS (BASEL, SWITZERLAND) 2023; 23:8084. [PMID: 37836914 PMCID: PMC10574982 DOI: 10.3390/s23198084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/19/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz-10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10-5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.
Collapse
Affiliation(s)
- Tom Van de Steene
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Emmeric Tanghe
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Luc Martens
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | | | | | - Wout Joseph
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| |
Collapse
|
12
|
Rong C, Yan L, Li L, Li Y, Liu M. A Review of Metamaterials in Wireless Power Transfer. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6008. [PMID: 37687701 PMCID: PMC10488467 DOI: 10.3390/ma16176008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/08/2023] [Accepted: 08/28/2023] [Indexed: 09/10/2023]
Abstract
Wireless power transfer (WPT) is a technology that enables energy transmission without physical contact, utilizing magnetic and electric fields as soft media. While WPT has numerous applications, the increasing power transfer distance often results in a decrease in transmission efficiency, as well as the urgent need for addressing safety concerns. Metamaterials offer a promising way for improving efficiency and reducing the flux density in WPT systems. This paper provides an overview of the current status and technical challenges of metamaterial-based WPT systems. The basic principles of magnetic coupling resonant wireless power transfer (MCR-WPT) are presented, followed by a detailed description of the metamaterial design theory and its application in WPT. The paper then reviews the metamaterial-based wireless energy transmission system from three perspectives: transmission efficiency, misalignment tolerance, and electromagnetic shielding. Finally, the paper summarizes the development trends and technical challenges of metamaterial-based WPT systems.
Collapse
Affiliation(s)
- Cancan Rong
- Jiangsu Province Laboratory of Mining Electric and Automation, China University of Mining and Technology, Xuzhou 221008, China; (C.R.); (L.Y.)
| | - Lihui Yan
- Jiangsu Province Laboratory of Mining Electric and Automation, China University of Mining and Technology, Xuzhou 221008, China; (C.R.); (L.Y.)
| | - Long Li
- Key Laboratory of High-Speed Circuit Design and EMC of Ministry of Education, School of Electronic Engineering, Xidian University, Xi’an 710071, China;
| | - Yunhui Li
- School of Physical Science and Engineering, Tongji University, Shanghai 200092, China;
| | - Minghai Liu
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
13
|
Akram MA, Ha S. A Differential Rectifier With V TH Compensation for High-Frequency RF Inputs. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:653-663. [PMID: 37023151 DOI: 10.1109/tbcas.2023.3264988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
A CMOS differential-drive bootstrap (BS) rectifier achieving an efficient dynamic threshold voltage ( VTH)-drop compensation at high-frequency RF inputs is proposed for small biomedical implants with wireless power transmission. A bootstrapping circuit with a dynamically controlled NMOS transistor and two capacitors is proposed to implement a dynamic VTH-drop compensation (DVC). The proposed bootstrapping circuit dynamically compensates the VTH drop of the main rectifying transistors by generating a compensation voltage only when the compensation is required, improving the power conversion efficiency (PCE) of the proposed BS rectifier. The proposed BS rectifier is designed for an ISM-band frequency of 433.92 MHz. A prototype of the proposed rectifier is co-fabricated in a 0.18- μm standard CMOS process with another configuration of the rectifier and two conventional BS rectifiers for fair performance comparison at various conditions. According to the measurement results, the proposed BS rectifier achieves better DC output voltage level, voltage conversion ratio, and PCE than the conventional BS rectifiers. With 0-dBm input power, 433.92-MHz frequency, and 3-k Ω load resistor, the proposed BS rectifier achieves a peak PCE of 68.5%.
Collapse
|
14
|
Aliqab K, Nadeem I, Khan SR. A Comprehensive Review of In-Body Biomedical Antennas: Design, Challenges and Applications. MICROMACHINES 2023; 14:1472. [PMID: 37512782 PMCID: PMC10385670 DOI: 10.3390/mi14071472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In-body biomedical devices (IBBDs) are receiving significant attention in the discovery of solutions to complex medical conditions. Biomedical devices, which can be ingested, injected or implanted in the human body, have made it viable to screen the physiological signs of a patient wirelessly, without regular hospital appointments and routine check-ups, where the antenna is a mandatory element for transferring bio-data from the IBBDs to the external world. However, the design of an in-body antenna is challenging due to the dispersion of the dielectric constant of the tissues and unpredictability of the organ structures of the human body, which can absorb most of the antenna radiation. Therefore, various factors must be considered for an in-body antenna, such as miniaturization, link budget, patient safety, biocompatibility, low power consumption and the ability to work effectively within acceptable medical frequency bands. This paper presents a comprehensive overview of the major facets associated with the design and challenges of in-body antennas. The review comprises surveying the design specifications and implementation methodology, simulation software and testing of in-body biomedical antennas. This work aims to summarize the recent in-body antenna innovations for biomedical applications and indicates the key research challenges.
Collapse
Affiliation(s)
- Khaled Aliqab
- Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia
| | - Iram Nadeem
- Department of Information Engineering and Mathematics Science, University of Siena, 53100 Siena, Italy
| | - Sadeque Reza Khan
- Institute of Sensors, Signals and Systems, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK
| |
Collapse
|
15
|
Tai YD, Widdicombe B, Unnithan RR, Grayden DB, John SE. Wearable Transmitter Coil Design for Inductive Wireless Power Transfer to Implantable Devices. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082593 DOI: 10.1109/embc40787.2023.10340600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Wireless endovascular sensors and stimulators are emerging biomedical technologies for applications such as endovascular pressure monitoring, hyperthermia, and neural stimulations. Recently, coil-shaped stents have been proposed for inductive power transfer to endovascular devices using the stent as a receiver. However, less work has been done on the external transmitter components, so the maximum power transferable remains unknown. In this work, we design and evaluate a wearable transmitter coil that allows 50 mW power transfer in simulation.Clinical Relevance-This allows more accurate measurements and precise control of endovascular devices.
Collapse
|
16
|
Ballardini G, Tamadon I, Guarnera D, Al-Haddad H, Iacovacci V, Mariottini F, Ricciardi S, Cucini A, Libera AD, Vistoli F, Menciassi A, Dario P, Cobelli C, Ricotti L. Controlling and powering a fully implantable artificial pancreas refillable by ingestible pills. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-7. [PMID: 38083764 DOI: 10.1109/embc40787.2023.10340006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Over the past decade, there has been a growing interest in the development of an artificial pancreas for intraperitoneal insulin delivery. Intraperitoneal implantable pumps guarantee more physiological glycemic control than subcutaneous wearable ones, for the treatment of type 1 diabetes. In this work, a fully implantable artificial pancreas refillable by ingestible pills is presented. In particular, solutions enabling the communication between the implanted pump and external user interfaces and novel control algorithms to intraperitoneally release an adequate amount of insulin based on glycemic data are shown. In addition, the powering and the wireless battery recharging are addressed. Specifically, the design and optimization of a customized transcutaneous energy transfer with two independent wireless channels are presented. The system was tested in terms of recharging efficacy, possible temperature rise within the body, during the recharging process and reliability of the wireless connection in the air and in the presence of ex vivo tissues.Clinical Relevance- This work aims to improve the control, battery recharging, and wireless communication of a fully implantable artificial pancreas for type 1 diabetes treatment.
Collapse
|
17
|
Luo J, Xue R, Cheong J, Zhang X, Yao L. Design and Optimization of Planar Spiral Coils for Powering Implantable Neural Recording Microsystem. MICROMACHINES 2023; 14:1221. [PMID: 37374807 DOI: 10.3390/mi14061221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/25/2023] [Accepted: 06/05/2023] [Indexed: 06/29/2023]
Abstract
This paper presents a design and optimization method utilizing inductive coupling coils for wireless power transfer in implantable neural recording microsystems, aiming at maximizing power transfer efficiency, which is essential for reducing externally transmitted power and ensuring biological tissue safety. The modeling of inductive coupling is simplified by combining semi-empirical formulations with theoretical models. By introducing the optimal resonant load transformation, the coil optimization is decoupled from an actual load impedance. The complete design optimization process of the coil parameters is given, which takes the maximum theoretical power transfer efficiency as the objective function. When the actual load changes, only the load transformation network needs to be updated instead of rerunning the entire optimization process. Planar spiral coils are designed to power neural recording implants given the challenges of limited implantable space, stringent low-profile restrictions, high-power transmission requirements and biocompatibility. The modeling calculation, electromagnetic simulation and measurement results are compared. The operating frequency of the designed inductive coupling is 13.56 MHz, the outer diameter of the implanted coil is 10 mm and the working distance between the external coil and the implanted coil is 10 mm. The measured power transfer efficiency is 70%, which is close to the maximum theoretical transfer efficiency of 71.9%, confirming the effectiveness of this method.
Collapse
Affiliation(s)
- Jie Luo
- School of Microelectronics, Shanghai University, Shanghai 201800, China
| | - Ruifeng Xue
- Shanghai Industrial Technology Research Institute, Shanghai 201899, China
| | - Jiahao Cheong
- Shanghai Industrial Technology Research Institute, Shanghai 201899, China
| | - Xuan Zhang
- Shanghai Industrial Technology Research Institute, Shanghai 201899, China
| | - Lei Yao
- School of Microelectronics, Shanghai University, Shanghai 201800, China
| |
Collapse
|
18
|
Yokoi K, Yasuda Y, Kanbe A, Imura T, Aoki S. Development of Wireless Power-Transmission-Based Photodynamic Therapy for the Induction of Cell Death in Cancer Cells by Cyclometalated Iridium(III) Complexes. Molecules 2023; 28:molecules28031433. [PMID: 36771099 PMCID: PMC9919167 DOI: 10.3390/molecules28031433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/24/2023] [Accepted: 01/29/2023] [Indexed: 02/05/2023] Open
Abstract
Photodynamic therapy (PDT), a noninvasive method for cancer therapy, involves the generation of reactive oxygen species (ROS) by the photochemical excitation of photosensitizers (PSs) to induce cell death in cancer cells. A variety of PS including porphyrin derivatives and metal complexes such as iridium (Ir) complexes have been reported. In clinical trials, red-near infrared (NIR) light (650-900 nm) is preferred for the excitation of PSs due to its deeper penetration into tissues compared with visible light (400-500 nm). To overcome this limitation, we established a PDT system that uses cyclometalated iridium(III) (Ir(III)) complexes that are excited with blue light in the wireless power transmission (WPT) system. To achieve this, we developed a light-emitting diode (LED) light device equipped with a receiver coil that receives electricity from the transmitter coil through magnetic resonance coupling. The LEDs in the receiving device use blue light (470 nm) to irradiate a given Ir(III) complex and excite triplet oxygen (3O2) to singlet oxygen (1O2) which induces cell death in HeLa S3 cells (human cervical carcinoma cells). The results obtained in this study suggest that WPT-based PDT represents a potentially new method for the treatment of tumors by a non-battery LED, which are otherwise difficult to treat by previous PDT systems.
Collapse
Affiliation(s)
- Kenta Yokoi
- Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
| | - Yoshitaka Yasuda
- Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
| | - Azusa Kanbe
- Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
| | - Takehiro Imura
- Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
- Correspondence: (T.I.); (S.A.); Tel.: +81-4-7121-3670 (S.A.)
| | - Shin Aoki
- Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
- Research Institute for Science and Technology (RIST), Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
- Research Institute for Biomedical Sciences (RIBS), Tokyo University of Science, 2641 Yamazaki, Noda 278-8510, Chiba, Japan
- Correspondence: (T.I.); (S.A.); Tel.: +81-4-7121-3670 (S.A.)
| |
Collapse
|
19
|
Current status of the preclinical evaluation of alternating electric fields as a form of cancer therapy. Bioelectrochemistry 2023; 149:108287. [DOI: 10.1016/j.bioelechem.2022.108287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/28/2022] [Accepted: 10/02/2022] [Indexed: 11/06/2022]
|
20
|
Zhuang H, Wang W, Yan G. Ferrite Concentrating and Shielding Structure Design of Wireless Power Transmitting Coil for Inductively Coupled Capsule Robot. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; PP:45-53. [PMID: 37022243 DOI: 10.1109/tbcas.2023.3241194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
High permeability material, especially the ferrite, has been widely used in wireless power transfer (WPT) to enhance the power transfer efficiency (PTE). However, for the WPT system of inductively coupled capsule robot, the ferrite core is solely introduced in power receiving coil (PRC) configuration to enhance the coupling. As for the power transmitting coil (PTC), very few studies focus on the ferrite structure design, and only the magnetic concentrating is taken into account without careful design. Therefore, a novel ferrite structure for PTC giving consideration to the magnetic field concentration as well as the mitigation and shielding of the leaked magnetic field is proposed in this paper. The proposed design is realized by combing the ferrite concentrating part and shielding part into a whole and providing a low reluctance closed path for magnetic induction lines, thereby improving the inductive coupling and PTE. Through analyses and simulations, the parameters of the proposed configuration are designed and optimized in terms of average magnetic flux density, uniformity, and shielding effectiveness. Prototypes of PTC with different ferrite configurations are established, tested, and compared to validate the performance enhancement. The experimental results indicate that the proposed design notably improves the average power delivered to the load from 373 mW to 822 mW and the PTE from 7.47% to 16.44%, with a relative percentage difference of 119.9%. Moreover, the power transfer stability is slightly enhanced from 91.7% to 92.8%.
Collapse
|
21
|
Ahn J, Woo S, Kim H, Song K, Huh S, Hong SE, Kim J, Choi HD, Ahn S. An Out-of-Phase Wireless Power Transfer System for Implantable Medical Devices to Reduce Human Exposure to Electromagnetic Field and Increase Power Transfer Efficiency. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1166-1180. [PMID: 36395127 DOI: 10.1109/tbcas.2022.3222011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
For the wireless power transfer (WPT) system in implantable medical devices (IMDs), human tissue is positioned between the transmitting and receiving coils which are different from general WPT systems. Because this space is where the strongest electromagnetic field (EMF) occurs, it is essential to reduce the EMF at the interspace to reduce human exposure to the EMF. In this paper, an out-of-phase coupled WPT system for IMDs is proposed to reduce human exposure to EMF. Considering the EMF exposure and power transfer efficiency (PTE) of the proposed system, a design procedure for determining the phase difference of each capacitor is analyzed and presented. Based on the equivalent circuit model analysis of the proposed system, the EMF and PTE characteristics of the WPT system depending on the design variables are comprehensively analyzed. The proposed system is compared with conventional systems through simulation and measurements. It is verified that the proposed system can reduce the EMF by 41.05% and increase the PTE by 9.62% compared to the conventional system. In addition, through simulation, human exposure to EMFs is assessed considering the exposure environment and electrical properties of human tissues. As a result, the current density, induced electric field, and specific absorption rate were reduced by 44.10%, 38.90%, and 63.82%, respectively.
Collapse
|
22
|
Proto A, Rufer L, Basrour S, Penhaker M. Modeling and Measurement of an Ultrasound Power Delivery System for Charging Implantable Devices Using an AlN-Based pMUT as Receiver. MICROMACHINES 2022; 13:2127. [PMID: 36557427 PMCID: PMC9788435 DOI: 10.3390/mi13122127] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/27/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
Ultrasound power delivery can be considered a convenient technique for charging implantable medical devices. In this work, an intra-body system has been modeled to characterize the phenomenon of ultrasound power transmission. The proposed system comprises a Langevin transducer as transmitter and an AlN-based square piezoelectric micro-machined ultrasonic transducer as receiver. The medium layers, in which elastic waves propagate, were made by polydimethylsiloxane to mimic human tissue and stainless steel to replace the case of the implantable device. To characterize the behavior of the transducers, measurements of impedance and phase, velocity and displacement, and acoustic pressure field were carried out in the experimental activity. Then, voltage and power output were measured to analyze the performance of the ultrasound power delivery system. For a root mean square voltage input of approximately 35 V, the power density resulted in 21.6 µW cm-2. Such a result corresponds to the data obtained with simulation through a one-dimensional lumped parameter transmission line model. The methodology proposed to develop the ultrasound power delivery (UPD) system, as well as the use of non-toxic materials for the fabrication of the intra-body elements, are a valid design approach to raise awareness of using wireless power transfer techniques for charging implantable devices.
Collapse
Affiliation(s)
- Antonino Proto
- Department of Neuroscience and Rehabilitation, University of Ferrara, Via Luigi Borsari, 46, 44121 Ferrara, Italy
- Department of Cybernetics and Biomedical Engineering, VŠB—Technical University of Ostrava, 17.listopadu 2172/15, Poruba, 708 00 Ostrava, Czech Republic
| | - Libor Rufer
- Université Grenoble Alpes, CNRS, Grenoble INP, TIMA, 38000 Grenoble, France
| | - Skandar Basrour
- Université Grenoble Alpes, CNRS, Grenoble INP, TIMA, 38000 Grenoble, France
| | - Marek Penhaker
- Department of Cybernetics and Biomedical Engineering, VŠB—Technical University of Ostrava, 17.listopadu 2172/15, Poruba, 708 00 Ostrava, Czech Republic
| |
Collapse
|
23
|
Karim ML, Bosnjak AM, McLaughlin J, Crawford P, McEneaney D, Escalona OJ. Transcutaneous Pulsed RF Energy Transfer Mitigates Tissue Heating in High Power Demand Implanted Device Applications: In Vivo and In Silico Models Results. SENSORS (BASEL, SWITZERLAND) 2022; 22:7775. [PMID: 36298125 PMCID: PMC9611940 DOI: 10.3390/s22207775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/29/2022] [Accepted: 10/08/2022] [Indexed: 06/16/2023]
Abstract
This article presents the development of a power loss emulation (PLE) system device to study and find ways of mitigating skin tissue heating effects in transcutaneous energy transmission systems (TETS) for existing and next generation left ventricular assist devices (LVADs). Skin thermal profile measurements were made using the PLE system prototype and also separately with a TETS in a porcine model. Subsequent data analysis and separate computer modelling studies permit understanding of the contribution of tissue blood perfusion towards cooling of the subcutaneous tissue around the electromagnetic coupling area. A 2-channel PLE system prototype and a 2-channel TETS prototype were implemented for this study. The heating effects resulting from power transmission inefficiency were investigated under varying conditions of power delivery levels for an implanted device. In the part of the study using the PLE setup, the implanted heating element was placed subcutaneously 6-8 mm below the body surface of in vivo porcine model skin. Two operating modes of transmission coupling power losses were emulated: (a) conventional continuous transmission, and (b) using our proposed pulsed transmission waveform protocols. Experimental skin tissue thermal profiles were studied for various levels of LVAD power. The heating coefficient was estimated from the porcine model measurements (an in vivo living model and a euthanised cadaver model without blood circulation at the end of the experiment). An in silico model to support data interpretation provided reliable experimental and numerical methods for effective wireless transdermal LVAD energization advanced solutions. In the separate second part of the study conducted with a separate set of pigs, a two-channel inductively coupled RF driving system implemented wireless power transfer (WPT) to a resistive LVAD model (50 Ω) to explore continuous versus pulsed RF transmission modes. The RF-transmission pulse duration ranged from 30 ms to 480 ms, and the idle time (no-transmission) from 5 s to 120 s. The results revealed that blood perfusion plays an important cooling role in reducing thermal tissue damage from TETS applications. In addition, the results analysis of the in vivo, cadaver (R1Sp2) model, and in silico studies confirmed that the tissue heating effect was significantly lower in the living model versus the cadaver model due to the presence of blood perfusion cooling effects.
Collapse
Affiliation(s)
- Mohammad L. Karim
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - Antonio M. Bosnjak
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - James McLaughlin
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - Paul Crawford
- Paul Crawford Veterinary Services, Larne BT40 3RW, UK
| | - David McEneaney
- Cardiovascular Research Unit, Craigavon Area Hospital, Portadown, Craigavon BT63 5QQ, UK
| | - Omar J. Escalona
- Nanotechnology & BioEngineering Research Centre, School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| |
Collapse
|
24
|
Zhao L, Annayev M, Oralkan O, Jia Y. An Ultrasonic Energy Harvesting IC Providing Adjustable Bias Voltage for Pre-Charged CMUT. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:842-851. [PMID: 35671313 DOI: 10.1109/tbcas.2022.3178581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Ultrasonic wireless power transmission (WPT) using pre-charged capacitive micromachined ultrasonic transducers (CMUT) is drawing great attention due to the easy integration of CMUT with CMOS techniques. Here, we present an integrated circuit (IC) that interfaces with a pre-charged CMUT device for ultrasonic energy harvesting. We implemented an adaptive high voltage charge pump (HVCP) in the proposed IC, which features low power, overvoltage stress (OVS) robustness, and a wide output range. The ultrasonic energy harvesting IC is fabricated in the 180 nm HV BCD process and occupies a 2 × 2.5 mm2 silicon area. The adaptive HVCP offers a 2× - 12× voltage conversion ratio (VCR), thereby providing a wide bias voltage range of 4 V-44 V for the pre-charged CMUT. Moreover, a VCR tunning finite state machine (FSM) implemented in the proposed IC can dynamically adjust the VCR to stabilize the HVCP output (i.e., the pre-charged CMUT bias voltage) to a target voltage in a closed-loop manner. Such a closed-loop control mechanism improves the tolerance of the proposed IC to the received power variation caused by misalignments, amount of transmitted power change, and/or load variation. Besides, the proposed ultrasonic energy harvesting IC has an average power consumption of 35 μW-554 μW corresponding to the HVCP output from 4 V-44 V. The CMUT device with a local surface acoustic intensity of 3.78 mW/mm2, which is well below the FDA limit for power flux (7.2 mW/mm2), can deliver sufficient power to the IC.
Collapse
|
25
|
Murliky L, Oliveira G, de Sousa FR, Brusamarello VJ. Tracking and Dynamic Tuning of a Wireless Powered Endoscopic Capsule. SENSORS (BASEL, SWITZERLAND) 2022; 22:6924. [PMID: 36146266 PMCID: PMC9506451 DOI: 10.3390/s22186924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/03/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
This work presents an inductive wireless power transfer system for powering an endoscopy capsule supplying energy to power electronic devices allocated inside a capsule of ≈26.1 mm × 9 mm. A receiver with three coils in quadrature with dimensions of ≈9 mm × 9 mm × 10 mm is located inside the capsule, moving freely inside a transmitter coil with 380 mm diameter through translations and revolutions. The proposed system tracks the variations of the equivalent magnetic coupling coefficient compensating misalignments between the transmitter and receiver coils. The power on the load is estimated and optimized from the transmitter, and the tracking control is performed by actuating on a capacitance in the matching network and on the voltage source frequency. The proposed system can prevent load overheating by limiting the power via adjusting of the magnitude of voltage source VS. Experimental results with uncertainties analysis reveal that, even at low magnetic coupling coefficients k ranging from (1.7 × 10-3, 3.5 × 10-3), the power on the load can be held within the range of 100-130 mW. These results are achieved with any position of the capsule in the space, limited by the diameter of the transmitter coil and height of 200 mm when adjusting the series capacitance of the transmitter in the range (17.4, 19.4) pF and the frequency of the power source in the range (802.1, 809.5) kHz.
Collapse
Affiliation(s)
- Lucas Murliky
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| | - Gustavo Oliveira
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| | - Fernando Rangel de Sousa
- Department of Electrical and Electronic Engineering, Universidade Federal de Santa Catarina, Florianópolis 88040-900, Brazil
| | - Valner João Brusamarello
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| |
Collapse
|
26
|
Kim HJ, Ho JS. Wireless interfaces for brain neurotechnologies. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210020. [PMID: 35658679 DOI: 10.1098/rsta.2021.0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/13/2021] [Indexed: 06/15/2023]
Abstract
Wireless interfaces enable brain-implanted devices to remotely interact with the external world. They are critical components in modern research and clinical neurotechnologies and play a central role in determining their overall size, lifetime and functionality. Wireless interfaces use a wide range of modalities-including radio-frequency fields, acoustic waves and light-to transfer energy and data to and from an implanted device. These forms of energy interact with living tissue through distinct mechanisms and therefore lead to systems with vastly different form factors, operating characteristics, and safety considerations. This paper reviews recent advances in the development of wireless interfaces for brain neurotechnologies. We summarize the requirements that state-of-the-art brain-implanted devices impose on the wireless interface, and discuss the working principles and applications of wireless interfaces based on each modality. We also investigate challenges associated with wireless brain neurotechnologies and discuss emerging solutions permitted by recent developments in electrical engineering and materials science. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Han-Joon Kim
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
| | - John S Ho
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
- The N.1 Institute for Health National University of Singapore, Queenstown, Singapore
- Institute for Health Innovation and Technology, National University of Singapore, Queenstown, Singapore
| |
Collapse
|
27
|
Lee TK, Jeong HB, Seo C, Seo JM. Manually wound coil fabrication process based on cyclic olefin copolymer substrate. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4131-4134. [PMID: 36086103 DOI: 10.1109/embc48229.2022.9871032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Neural prostheses are systems that interact with the human nervous system to recover function lost as a result of disease by recording or stimulating neural signals. Neural implants have a variety of components, but among them, designing highly efficient wireless power transmission systems is particularly important. However, there is a problem that it is difficult to design a wireless power transmission system with high transmission efficiency because power transmission efficiency is affected by various coil parameters. In addition, nerve implants are mainly designed based on polymer substrates, but studies have not been conducted on the process of manufacturing coils based on polymer substrates. In this study, to overcome the mentioned problems, an easy and fast manufacturing process was proposed before designing a precise coil on a polymer substrate. Coil was made by manually winding the 200um copper wire, and the coil was packaged using COC. The coil feasibility test was conducted after fabrication to evaluate the performance of fabrication process. It did not fit the expected frequency because the wire was manually wound to make a small size coil. However, the wire wound coil is expected to be more efficient than the coil made through the PCB process, and if the sophistication is supplemented, it can be used as a highly efficient coil for wireless power transmission.
Collapse
|
28
|
Zhu Y, Li S, Li J, Falcone N, Cui Q, Shah S, Hartel MC, Yu N, Young P, de Barros NR, Wu Z, Haghniaz R, Ermis M, Wang C, Kang H, Lee J, Karamikamkar S, Ahadian S, Jucaud V, Dokmeci MR, Kim HJ, Khademhosseini A. Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2108389. [PMID: 35130584 PMCID: PMC9233032 DOI: 10.1002/adma.202108389] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/27/2022] [Indexed: 05/09/2023]
Abstract
The eye is one of the most complex organs in the human body, containing rich and critical physiological information (e.g., intraocular pressure, corneal temperature, and pH) as well as a library of metabolite biomarkers (e.g., glucose, proteins, and specific ions). Smart contact lenses (SCLs) can serve as a wearable intelligent ocular prosthetic device capable of noninvasive and continuous monitoring of various essential physical/biochemical parameters and drug loading/delivery for the treatment of ocular diseases. Advances in SCL technologies and the growing public interest in personalized health are accelerating SCL research more than ever before. Here, the current status and potential of SCL development through a comprehensive review from fabrication to applications to commercialization are discussed. First, the material, fabrication, and platform designs of the SCLs for the diagnostic and therapeutic applications are discussed. Then, the latest advances in diagnostic and therapeutic SCLs for clinical translation are reviewed. Later, the established techniques for wearable power transfer and wireless data transmission applied to current SCL devices are summarized. An outlook, future opportunities, and challenges for developing next-generation SCL devices are also provided. With the rise in interest of SCL development, this comprehensive and essential review can serve as a new paradigm for the SCL devices.
Collapse
Affiliation(s)
- Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Shaopei Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Jinghang Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- School of Engineering, Westlake University, Hangzhou, Zhejiang Province, 310024, China
- School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan, Hubei Province, 430205, China
| | - Natashya Falcone
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Qingyu Cui
- Department of Medicine, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Shilp Shah
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Martin C Hartel
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Ning Yu
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, 92521, USA
| | - Patric Young
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | | | - Zhuohong Wu
- Department of Nanoengineering, University of California-San Diego, San Diego, CA, 92093, USA
| | - Reihaneh Haghniaz
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Menekse Ermis
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Canran Wang
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Heemin Kang
- Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Junmin Lee
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea
| | | | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Vadim Jucaud
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Mehmet R Dokmeci
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Han-Jun Kim
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| |
Collapse
|
29
|
Next-Generation Wireless Charging Systems for Mobile Devices. ENERGIES 2022. [DOI: 10.3390/en15093119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Wireless power transfer (WPT) is currently sparking more attention towards the application of wireless charging for mobile devices and electric vehicles [...]
Collapse
|
30
|
Using Overlapped Resonators in Wireless Power Transfer for Uniform Electromagnetic Field and Removing Blank Spots in Free Moving Applications. ELECTRONICS 2022. [DOI: 10.3390/electronics11081204] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We propose an induction link based on overlapping arrays to eliminate blank spots on the electromagnetic field for moving object applications. We use two arrays of four aligned coils that have a 50% overlap between the two plates. This mechanism compensates for the internal coil power drop at positions in the boundaries between two adjacent external coils. We showed that if these plates are excited, a uniform electromagnetic field is created in the movement direction of the moving object. This uniform electromagnetic field distribution will result in a constant receiving power at all points in the path of the moving internal coil with the same power consumption of one coil excitation. Power delivery to the moving object tolerance reaches 10% at most, while, in non-overlapped scenarios, it is approximately 50%. In addition, according to the theoretical calculations, printed circuit coils (PCB) for the array are designed for maximum efficiency. We found that the change in distance and dimensions of the receiver coil has a linear effect on power and efficiency. Moreover, a Specific Absorption Rate (SAR) simulation was performed for biocompatibility. In this paper, we investigate and record a 68% electrical power efficiency for the fabricated system. The array consists of eight transmitters coils of the same size and shape and a receiver coil at a distance of 4 cm. Furthermore, the fabricated coil has shown improved efficiency compared to similar studies in the literature and introduces a promising structure for bio-test applications.
Collapse
|
31
|
Wireless Low-Power Transfer for Galvanically Isolated High-Voltage Applications. ELECTRONICS 2022. [DOI: 10.3390/electronics11060923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
For various applications, such as gate drivers for transistors, wireless chargers for mobile devices and cars, and isolated measurement equipment, an isolated DC power supply for electronic components is required. In this work, a new concept for an isolated power supply with insulation strength of 50 kV and power transmission of up to 60 W to supply measurement equipment with 12 or 24 V is presented. Furthermore, high overall efficiency of 82.5% at 55 W is achieved. Feasibility is demonstrated in a real application powering data acquisition electronics at high reference potential. Our new concept uses a coreless printed circuit board (PCB) transformer (15 cm × 10 cm × 4 cm and a weight of 480 g) designed for maximum efficiency via a coil layout and close proximity of adjacent coils on one PCB while reaching high isolation strength via the PCB material and potted coils. To increase efficiency, we investigated different coil geometries at different frequencies. A low-cost design consisting of two Qi charging coils mounted on one PCB is compared with our integrated PCB transformers manufactured from a four-layer PCB with ferrites applied on the outside. With this new design, high isolation voltages are possible while reaching high transformer efficiency of up to 90%.
Collapse
|
32
|
SAHARA GENTA, HIJIKATA WATARU, INOUE YUSUKE, YAMADA AKIHIRO, SHIRAISHI YASUYUKI, FUKAYA AOI, KARUBE MASATO, GENDA TATSUYA, IWAMOTO NAOKI, TACHIZAKI YUMA, MORITA RYOSUKE, YAMBE TOMOYUKI. METHODS FOR INVESTIGATING CONTRACTION CHARACTERISTICS OF A PART OF MUSCLES FOR IMPLANTABLE POWER GENERATION SYSTEMS. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
To develop a power generation system as a solution to the power supply problems of small active implantable medical devices, we proposed a new method to examine muscles using skeletal muscle contraction through electrical stimulation. Realization of the system requires data on the contraction characteristics of a part of the muscles through which blood flows; thus, a dedicated setup was built and verified using a goat. The connecting parts were attached to two points in the large muscle of the goat’s trunk; one was fixed and the other slid along the guide. The distance and force between the two points, approaching each other, were measured by contracting the muscle between the points using electrical stimulation and pulling the measurement cart. The contraction distance and force were measured simultaneously, and the dynamic work of the contraction was calculated. The muscle work occurred with almost the same time delay regardless of the load, and the work tended to be greater when the contraction force, and not the contraction distance, of the muscle was large. The setup is physiological, simple, and versatile. Our setup can potentially be used in the development of implantable power generation systems and in other related fields.
Collapse
Affiliation(s)
- GENTA SAHARA
- Department of Medical Engineering and Cardiology, Institute of Development, Aging and Cancer, Tohoku University, Seiryo-machi 4-1, Aoba-ku, Sendai-shi, Miyagi-ken 980-8575, Japan
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
- Department of Plastic and Reconstructive Surgery, Tohoku University Hospital, Miyagi, Japan
| | - WATARU HIJIKATA
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - YUSUKE INOUE
- Institute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan
- Advanced Medical Engineering Research Center, Asahikawa Medical University, Hokkaido, Japan
| | - AKIHIRO YAMADA
- Institute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan
| | - YASUYUKI SHIRAISHI
- Institute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan
| | - AOI FUKAYA
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - MASATO KARUBE
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - TATSUYA GENDA
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - NAOKI IWAMOTO
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - YUMA TACHIZAKI
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - RYOSUKE MORITA
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
| | - TOMOYUKI YAMBE
- Graduate School of Biomedical Engineering, Tohoku University, Miyagi, Japan
- Institute of Development, Aging and Cancer, Tohoku University, Miyagi, Japan
| |
Collapse
|
33
|
Xiong Q, Shao Y, Sun P, Sun J, Rong E, Liang Y. Constant output characteristics and design methodology of double side LC compensated capacitive power transfer. Sci Rep 2022; 12:2663. [PMID: 35177706 PMCID: PMC8854664 DOI: 10.1038/s41598-022-06577-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 01/31/2022] [Indexed: 11/09/2022] Open
Abstract
Capacitive power transfer (CPT) has been verified to be capable of transferring a power level as high as inductive power transfer (IPT) recently, and has its own merits. It is a well complement of IPT in near-field wireless power transfer (WPT). This paper gives a newly designed method of realizing both constant output voltage (COV) and constant output current (COC) modes of double side LC compensated CPT. Firstly, through analysis of basic circuit characteristics, the conditions for both of the two modes are deduced theoretically. Especially, one merit of the method is that the conditions indicate a very clear relationship between the compensation components forming resonant tanks. Another merit is that the couple capacitors also participate in resonant tanks. Different from the COV mode, the COC mode can theoretically reach zero phase angle condition simultaneously. Based on these conditions, the parameter design methodology is proposed. Besides, an efficient model of double side LC compensated CPT is built, and the optimum load is calculated theoretically to guide the design course. Finally, the results of both simulations and experiments demonstrate high consistency with the theoretical analysis.
Collapse
Affiliation(s)
- Qiao Xiong
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China
| | - Ying Shao
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China.
| | - Pan Sun
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China
| | - Jun Sun
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China
| | - Enguo Rong
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China
| | - Yan Liang
- College of Electrical Engineering, Naval University of Engineering, Wuhan, 430000, Hubei, China
| |
Collapse
|
34
|
Hussain I, Woo DK. Simplified Mutual Inductance Calculation of Planar Spiral Coil for Wireless Power Applications. SENSORS 2022; 22:s22041537. [PMID: 35214439 PMCID: PMC8876344 DOI: 10.3390/s22041537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/10/2022] [Accepted: 02/14/2022] [Indexed: 12/10/2022]
Abstract
In this paper, a simplified method for the calculation of a mutual inductance of the planar spiral coil, motivated from the Archimedean spiral, is presented. This method is derived by solving Neumann's integral formula in a cylindrical coordinate system, and a numerical tool is used to determine the value of mutual inductance. This approach can calculate the mutual inductances accurately at various coaxial and non-coaxial distances for different coil geometries. The calculation result is compared with the 3D finite element analyses to verify its accuracy, which shows good consistency. Furthermore, to confirm it experimentally, Litz wire is used to fabricate the sample spiral coils. Finally, the comparison of a simplified method is also studied relative to the coupling coefficient. The accuracy of the calculation results with the simulation and the measurement results makes it a good candidate to apply it in wireless power applications.
Collapse
|
35
|
Domajnko J, Milanovič M, Prosen N. 3D Platform for Coupling Coefficient Evaluation of an Inductive Power Transfer Systems. SENSORS 2022; 22:s22041445. [PMID: 35214347 PMCID: PMC8876809 DOI: 10.3390/s22041445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 01/26/2022] [Accepted: 02/08/2022] [Indexed: 01/27/2023]
Abstract
This paper presents a custom-made, computer-connected, and controlled 3D platform that enables the evaluation of the coupling coefficient between the transmitter and receiver coil parts of an inductive wireless power transfer (IPT) system. The platform includes a computer application, a 3D positioning mechanism, and an inductance measurement circuit. The positioning mechanism moves the coils to the point in 3D space, and the inductance circuit measures the mutual inductance between the transmitter and the receiver coil. The measured value can be used to calculate the coupling coefficient between the transmitter and the receiver coil. The data are sent to the computer for further visualisation. The transmitter and the receiver coil can be evaluated by measuring the coupling coefficient between them in multiple points in space. Measurements performed with the platform can be used in the design and evaluation phases of inductive wireless power transfer systems and to extrapolate the polynomial function of the coupling coefficient in relation to the distance between coils or their misalignment.
Collapse
|
36
|
Revisiting the Analysis of Radiative Mid-Range Wireless Link for Pacemakers. SENSORS 2022; 22:s22030947. [PMID: 35161689 PMCID: PMC8839276 DOI: 10.3390/s22030947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 01/17/2022] [Accepted: 01/24/2022] [Indexed: 02/01/2023]
Abstract
The development of a wireless link for biomedical applications requires an accurate estimation of the delivered power to implanted devices. In particular, a variety of mid-range applications in the biomedical area have gained significant attention. An appropriate method for the mid-range wireless link is required to implement a continuous wireless link through human tissue. Even though formulas used in this work are all based on previous works, this paper presents an implementation of the diverse formulas for the mid-range wireless link of an implanted antenna used for a pacemaker system based on the understanding on radiation properties varied with the distances from the antenna. The formulas based on input far-field data are successfully applied to compute the power transmission for the implanted devices, whose range includes radiative near-field and far-field regions. The wireless link for a pacemaker system is evaluated through using a patch antenna immersed with different depths of human tissue. A comparison of the computed and measured results shows an excellent agreement where the validity of the evaluation is demonstrated.
Collapse
|
37
|
Wireless Torque and Power Transfer Using Multiple Coils with LCC-S Topology for Implantable Medical Drug Pump. SENSORS 2021; 21:s21238150. [PMID: 34884150 PMCID: PMC8662434 DOI: 10.3390/s21238150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/18/2021] [Accepted: 12/03/2021] [Indexed: 12/23/2022]
Abstract
In this paper, we propose a method of wirelessly torque transfer (WTT) and power (WPT) to a drug pump, one of implantable medical devices. By using the magnetic field generated by the WPT system to transfer torque and power to the receiving coil at the same time, applications that previously used power from the battery can be operated without a battery. The proposed method uses a receiving coil with magnetic material as a motor, and can generate torque in a desired direction using the magnetic field from the transmitting coil. The WPT system was analyzed using a topology that generates a constant current for stable torque generation. In addition, a method for detecting the position of the receiving coil without using additional power was proposed. Through simulations and experiments, it was confirmed that WTT and WPT were possible at the same time, and in particular, it was confirmed that WTT was stably possible.
Collapse
|
38
|
Yi X, Zheng W, Cao H, Wang S, Feng X, Yang Z. Wireless Power Transmission for Implantable Medical Devices Using Focused Ultrasound and a Miniaturized 1-3 Piezoelectric Composite Receiving Transducer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3592-3598. [PMID: 34357865 DOI: 10.1109/tuffc.2021.3103099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Wireless power transmission (WPT) using ultrasound is a promising way for wirelessly recharging implantable medical devices (IMDs). However, the transmitted power using ultrasound so far is insufficient for driving the existing IMDs. Moreover, the size of the receiving transducer is larger, which is not suitable for implantation. To increase the output power and reduce the size of the implantable receiver, this article presents a method of combining focused ultrasound with a miniaturized 1-3 piezoelectric composite receiving transducer to produce higher electrical power. An analytical fluid-structure interaction model is constructed to fully understand the operating mechanism of the receiving transducer under ultrasonic force. In our experiments, a miniaturized 1-3 piezoelectric composite receiving transducer with a diameter of 3.7 mm was used. The output power generated from the receiving transducer reached 60 mW at a distance of 150 mm. In vitro and in vivo animal experiments proved that the miniaturized transducer could successfully receive focused ultrasonic energy and convert it to electrical power. The method presented and the electrical power that we obtained can provide a valuable reference for wirelessly charging of IMDs.
Collapse
|
39
|
Missey F, Botzanowski B, Migliaccio L, Acerbo E, Głowacki ED, Williamson A. Organic electrolytic photocapacitors for stimulation of the mouse somatosensory cortex. J Neural Eng 2021; 18. [PMID: 34749345 DOI: 10.1088/1741-2552/ac37a6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 11/08/2021] [Indexed: 12/20/2022]
Abstract
Objective.For decades electrical stimulation has been used in neuroscience to investigate brain networks and been deployed clinically as a mode of therapy. Classically, all methods of electrical stimulation require implanted electrodes to be connected in some manner to an apparatus which provides power for the stimulation itself.Approach. We show the use of novel organic electronic devices, specifically organic electrolytic photocapacitors (OEPCs), which can be activated when illuminated with deep-red wavelengths of light and correspondingly do not require connections with external wires or power supplies when implanted at various depthsin vivo. Main results. We stimulated cortical brain tissue of mice with devices implanted subcutaneously, as well as beneath both the skin and skull to demonstrate a wireless stimulation of the whisker motor cortex. Devices induced both a behavior response (whisker movement) and a sensory response in the corresponding sensory cortex. Additionally, we showed that coating OEPCs with a thin layer of a conducting polymer formulation (PEDOT:PSS) significantly increases their charge storage capacity, and can be used to further optimize the applied photoelectrical stimulation.Significance. Overall, this new technology can provide an on-demand electrical stimulation by simply using an OEPC and a deep-red wavelength illumination. Wires and interconnects to provide power to implanted neurostimulation electrodes are often problematic in freely-moving animal research and with implanted electrodes for long-term therapy in patients. Our wireless brain stimulation opens new perspectives for wireless electrical stimulation for applications in fundamental neurostimulation and in chronic therapy.
Collapse
Affiliation(s)
- Florian Missey
- Institut de Neurosciences des Systèmes (INS), INSERM, UMR_1106, Aix-Marseille Université, Marseille, France
| | - Boris Botzanowski
- Institut de Neurosciences des Systèmes (INS), INSERM, UMR_1106, Aix-Marseille Université, Marseille, France
| | - Ludovico Migliaccio
- Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - Emma Acerbo
- Institut de Neurosciences des Systèmes (INS), INSERM, UMR_1106, Aix-Marseille Université, Marseille, France
| | - Eric Daniel Głowacki
- Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic.,Laboratory of Organic Electronics, Campus Norrköping, Linköping University, SE-60174 Norrköping, Sweden
| | - Adam Williamson
- Institut de Neurosciences des Systèmes (INS), INSERM, UMR_1106, Aix-Marseille Université, Marseille, France.,Laboratory of Organic Electronics, Campus Norrköping, Linköping University, SE-60174 Norrköping, Sweden.,Center for Bioelectronic Medicine, Department of Medicine, Solna, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
40
|
Gao H, Lin Y, Monge M. Towards Magnetic Field Gradient-Based Imaging and Control of In-Body Devices. IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE : HEALTHCARE TECHNOLOGY : [PROCEEDINGS]. IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE 2021; 2021:10.1109/biocas49922.2021.9645032. [PMID: 35356802 PMCID: PMC8963196 DOI: 10.1109/biocas49922.2021.9645032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This papers reports a magnetic field gradient-based imaging system for in-body devices which takes inspiration from the localization principles of magnetic resonance imaging. By applying three orthogonal magnetic field gradients, the location of a device inside the body can be determined by measuring the magnetic fields in the device and transmitting this information to an external reader. The proposed system consists of one pair of Helmholtz coils and two pairs of saddle coils and is capable of generating the three orthogonal gradient fields. To emulate an implantable device, a miniature sensor module was designed using off-the-shelf components and semi-passive UHF RFID. The proposed localization system produces magnetic field gradients up to 187.4 G/m while consuming 1 A and achieves an average localization error of 80 μm.
Collapse
Affiliation(s)
- Hongxiang Gao
- University of Southern California, Los Angeles, CA 90089, USA
| | - Yubin Lin
- University of Southern California, Los Angeles, CA 90089, USA
| | - Manuel Monge
- University of Southern California, Los Angeles, CA 90089, USA
| |
Collapse
|
41
|
Li J, Wang X. Materials Perspectives for Self-Powered Cardiac Implantable Electronic Devices toward Clinical Translation. ACCOUNTS OF MATERIALS RESEARCH 2021; 2:739-750. [PMID: 35386361 PMCID: PMC8979373 DOI: 10.1021/accountsmr.1c00078] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Represented by pacemakers, implantable electronic devices (CIEDs) are playing a vital life-saving role in modern society. Although the current CIEDs are evolving quickly in terms of performance, safety, and miniaturization, the bulky and rigid battery creates the largest hurdle toward further development of a soft system that can be attached and conform to tissues without causing undesirable physiologic changes. Over 50% of patients with pacemakers require additional surgery procedures to replace a drained battery. Abrupt battery malfunction and failure contributes up to 2.4% of implanted leadless pacemakers. The battery also has risks of lethal interference with diagnostic magnetic resonance imaging (MRI). Applying the implantable nanogenerators (i-NGs) technology to CIEDs is regarded as a promising solution to the battery challenge and enables self-powering capability. I-NGs based on the principle of either triboelectricity (TENG) or piezoelectricity (PENG) can convert biomechanical energy into electricity effectively. Meanwhile, a complete heartbeat cycle provides a biomechanical energy of ~0.7 J or an average power of 0.93 W, which is sufficient for the operation of CIEDs considering the power consumption of 5-10 μW for a pacemaker and 10-100 μW for a cardiac defibrillator. It is therefore practical to leverage the effective, soft, flexible, lightweight, and biocompatible i-NGs to eliminate the bulky battery component in CIEDs and achieve self-sustainable operation. In this rapidly evolving interdisciplinary field, materials innovation acts as a cornerstone that frames the technology development. Here we bring a few critical perspectives regarding materials design and engineering, which are essential in leading the NG-powered CIEDs toward clinical translations. This Account starts with a brief introduction of the cardiac electrophysiology, as well as its short history to interface the state-of-the-art cardiac NG technologies. Three key components of NG-powered CIEDs are discussed in detail, including the NG device itself, the packaging material, and the stimulation electrodes. Cardiac NG is the essential component that converts heartbeat energy into electricity. It demands high-performance electromechanical coupling materials with long-term dynamic stability. The packaging material is critical to ensure a long-term stable operation of the device on a beating heart. Given the unique operation environment, a few criteria need to be considered in its development, including flexibility, biocompatibility, antifouling, hemocompatibility, and bioadhesion. The stimulation electrodes are the only material interfacing the heart tissue electrically. They should provide capacitive charge injection and mimic the soft and wet intrinsic tissues for the sake of stable biointerfaces. Driven by the rapid materials and device advancement, we envision that the evolution of NG-based CIEDs will quickly move from epicardiac to intracardiac, from single-function to multifunction, and with a minimal-invasive implantation procedure. This trend of development will open many research opportunities in emerging materials science and engineering, which will eventually lead the NG technology to a prevailing strategy for powering future CIEDs.
Collapse
Affiliation(s)
- Jun Li
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Xudong Wang
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| |
Collapse
|
42
|
Molloy A, Beaumont K, Alyami A, Kirimi M, Hoare D, Mirzai N, Heidari H, Mitra S, Neale SL, Mercer JR. Challenges to the development of the next generation of self-reporting cardiovascular implantable medical devices. IEEE Rev Biomed Eng 2021; 15:260-272. [PMID: 34520361 DOI: 10.1109/rbme.2021.3110084] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cardiovascular disease (CVD) is a group of heart and vasculature conditions which are the leading form of mortality worldwide. Blood vessels can become narrowed, restricting blood flow, and drive the majority of hearts attacks and strokes. Surgical interventions are frequently required; including percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG). Despite successful opening of vessels and restoration of blood flow, often in-stent restenosis (ISR) and graft failure can still occur, resulting in subsequent patient morbidity and mortality. A new generation of cardiovascular implants that have sensors and real-time monitoring capabilities are being developed to combat ISR and graft failure. Self-reporting stent/graft technology could enable precision medicine-based healthcare by detecting the earliest features of disease, even before symptoms occur. Bringing an implantable medical device with wireless electronic sensing capabilities to market is complex and often obstructive undertaking. This critical review analyses the obstacles that need to be overcome for self-reporting stents/grafts to be developed and provide a precision-medicine based healthcare for cardiovascular patients. Here we assess the latest research and technological advancement in the field, the current devices and the market potential for their end-user implementation.
Collapse
|
43
|
Takahashi F, Tanaka R, Arai Y, Tatsumi H, Jin J. Electrochemiluminescence of Tris(2,2'-bipyridine)ruthenium(II)/Tri-n-propylamine with an Electric Contactless Power Transfer System. ANAL SCI 2021; 37:1309-1313. [PMID: 33678726 DOI: 10.2116/analsci.21a002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
An electrochemiluminescence (ECL) analytical device was developed using an electric contactless power transfer system. A mutually induced electromotive voltage was generated by wrapping an enameled wire around a commercial contactless charger. There was no electrical contact between the power supply and the electrochemical cell. For the tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)32+)/tri-n-propylamine system, a weak ECL signal was observed. When an inexpensive rectifier diode was introduced between the coil and the working electrode, the ECL intensity detection sensitivity increased by more than 100 times. The relationship between the waveform of the applied voltage and the ECL response was clarified, and the optimum conditions were determined. The intensity of the induced electromotive voltage was easily controlled by changing the number of turns in the coil. The proposed method is a safe, simple, and inexpensive technique without electrical contact.
Collapse
Affiliation(s)
| | - Ryutaro Tanaka
- Department of Chemistry, Faculty of Science, Shinshu University
| | - Yuta Arai
- Department of Chemistry, Faculty of Science, Shinshu University
| | | | - Jiye Jin
- Department of Chemistry, Faculty of Science, Shinshu University
| |
Collapse
|
44
|
Turner BL, Senevirathne S, Kilgour K, McArt D, Biggs M, Menegatti S, Daniele MA. Ultrasound-Powered Implants: A Critical Review of Piezoelectric Material Selection and Applications. Adv Healthc Mater 2021; 10:e2100986. [PMID: 34235886 DOI: 10.1002/adhm.202100986] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 06/15/2021] [Indexed: 12/14/2022]
Abstract
Ultrasound-powered implants (UPIs) represent cutting edge power sources for implantable medical devices (IMDs), as their powering strategy allows for extended functional lifetime, decreased size, increased implant depth, and improved biocompatibility. IMDs are limited by their reliance on batteries. While batteries proved a stable power supply, batteries feature relatively large sizes, limited life spans, and toxic material compositions. Accordingly, energy harvesting and wireless power transfer (WPT) strategies are attracting increasing attention by researchers as alternative reliable power sources. Piezoelectric energy scavenging has shown promise for low power applications. However, energy scavenging devices need be located near sources of movement, and the power stream may suffer from occasional interruptions. WPT overcomes such challenges by more stable, on-demand power to IMDs. Among the various forms of WPT, ultrasound powering offers distinct advantages such as low tissue-mediated attenuation, a higher approved safe dose (720 mW cm-2 ), and improved efficiency at smaller device sizes. This study presents and discusses the state-of-the-art in UPIs by reviewing piezoelectric materials and harvesting devices including lead-based inorganic, lead-free inorganic, and organic polymers. A comparative discussion is also presented of the functional material properties, architecture, and performance metrics, together with an overview of the applications where UPIs are being deployed.
Collapse
Affiliation(s)
- Brendan L. Turner
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
| | - Seedevi Senevirathne
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Katie Kilgour
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Darragh McArt
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Manus Biggs
- Centre for Research in Medical Devices National University of Ireland Newcastle Road Galway H91 W2TY Ireland
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Michael A. Daniele
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
- Department of Electrical and Computer Engineering North Carolina State University 890 Oval Dr. Raleigh NC 27695 USA
| |
Collapse
|
45
|
Faria A, Marques L, Ferreira C, Alves F, Cabral J. A Fast and Precise Tool for Multi-Layer Planar Coil Self-Inductance Calculation. SENSORS 2021; 21:s21144864. [PMID: 34300602 PMCID: PMC8309821 DOI: 10.3390/s21144864] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 07/07/2021] [Accepted: 07/13/2021] [Indexed: 11/16/2022]
Abstract
An open-source tool that allows for a fast and precise analytical calculation of multi-layer planar coils self-inductance, without any geometry limitation is proposed here. The process of designing and simulating planar coils to achieve reliable results is commonly limited on accuracy and or geometry, or are too time-consuming and expensive, thus a tool to speed up this design process is desired. The model is based on Grover equations, valid for any geometry. The validation of the tool was performed through the comparison with experimental measurements, Finite Element Model (FEM) simulations, and the main analytical methods usually used in literature, with errors registered to be below 2.5%, when compared to standard FEM simulations, and when compared to experimental measurements they are below 10% in the case of the 1-layer coils, and below 5% in the 2-layer coils (without taking into consideration the coil connectors). The proposed model offers a new approach to the calculation of the self-inductance of planar coils of several layers that combines precision, speed, independence of geometry, easy interaction, and no need for extra resources.
Collapse
Affiliation(s)
- Andreia Faria
- ALGORITMI Center, University of Minho, 4800-058 Guimarães, Portugal;
- Correspondence:
| | - Luís Marques
- Centre of Physics of Minho and Porto Universities, 4710-057 Braga, Portugal;
| | | | - Filipe Alves
- Integrated Micro and Nanotechnologies, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal;
| | - Jorge Cabral
- ALGORITMI Center, University of Minho, 4800-058 Guimarães, Portugal;
- CEiiA—Centro de Engenharia e Desenvolvimento, 4450-017 Matosinhos, Portugal
| |
Collapse
|
46
|
Mittal N, Ojanguren A, Niederberger M, Lizundia E. Degradation Behavior, Biocompatibility, Electrochemical Performance, and Circularity Potential of Transient Batteries. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:2004814. [PMID: 34194934 PMCID: PMC8224425 DOI: 10.1002/advs.202004814] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/02/2021] [Indexed: 05/08/2023]
Abstract
Transient technology seeks the development of materials, devices, or systems that undergo controlled degradation processes after a stable operation period, leaving behind harmless residues. To enable externally powered fully transient devices operating for longer periods compared to passive devices, transient batteries are needed. Albeit transient batteries are initially intended for biomedical applications, they represent an effective solution to circumvent the current contaminant leakage into the environment. Transient technology enables a more efficient recycling as it enhances material retrieval rates, limiting both human and environmental exposures to the hazardous pollutants present in conventional batteries. Little efforts are focused to catalog and understand the degradation characteristics of transient batteries. As the energy field is a property-driven science, not only electrochemical performance but also their degradation behavior plays a pivotal role in defining the specific end-use applications. The state-of-the-art transient batteries are critically reviewed with special emphasis on the degradation mechanisms, transiency time, and biocompatibility of the released degradation products. The potential of transient batteries to change the current paradigm that considers batteries as harmful waste is highlighted. Overall, transient batteries are ready for takeoff and hold a promising future to be a frontrunner in the uptake of circular economy concepts.
Collapse
Affiliation(s)
- Neeru Mittal
- Laboratory for Multifunctional MaterialsDepartment of MaterialsETH ZürichVladimir‐Prelog‐Weg 5Zürich8093Switzerland
| | - Alazne Ojanguren
- Laboratory for Multifunctional MaterialsDepartment of MaterialsETH ZürichVladimir‐Prelog‐Weg 5Zürich8093Switzerland
| | - Markus Niederberger
- Laboratory for Multifunctional MaterialsDepartment of MaterialsETH ZürichVladimir‐Prelog‐Weg 5Zürich8093Switzerland
| | - Erlantz Lizundia
- Laboratory for Multifunctional MaterialsDepartment of MaterialsETH ZürichVladimir‐Prelog‐Weg 5Zürich8093Switzerland
- Life Cycle Thinking GroupDepartment of Graphic Design and Engineering ProjectsFaculty of Engineering in BilbaoUniversity of the Basque Country (UPV/EHU)Bilbao48013Spain
- BCMaterialsBasque Center for MaterialsApplications and NanostructuresUPV/EHU Science ParkLeioa48940Spain
| |
Collapse
|
47
|
Model-Based Systems Engineering Applied to Trade-Off Analysis of Wireless Power Transfer Technologies for Implanted Biomedical Microdevices. SENSORS 2021; 21:s21093201. [PMID: 34063000 PMCID: PMC8124370 DOI: 10.3390/s21093201] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/29/2021] [Accepted: 05/01/2021] [Indexed: 12/28/2022]
Abstract
Decision-making is an important part of human life and particularly in any engineering process related to a complex product. New sensors and actuators based on MEMS technologies are increasingly complex and quickly evolving into products. New biomedical implanted devices may benefit from system engineering approaches, previously reserved to very large projects, and it is expected that this need will increase in the future. Here, we propose the application of Model Based Systems Engineering (MBSE) to systematize and optimize the trade-off analysis process. The criteria, their utility functions and the weighting factors are applied in a systematic way for the selection of the best alternative. Combining trade-off with MBSE allow us to identify the more suitable technology to be implemented to transfer energy to an implanted biomedical micro device.
Collapse
|
48
|
Stuart T, Cai L, Burton A, Gutruf P. Wireless and battery-free platforms for collection of biosignals. Biosens Bioelectron 2021; 178:113007. [PMID: 33556807 PMCID: PMC8112193 DOI: 10.1016/j.bios.2021.113007] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/02/2021] [Accepted: 01/14/2021] [Indexed: 02/06/2023]
Abstract
Recent progress in biosensors have quantitively expanded current capabilities in exploratory research tools, diagnostics and therapeutics. This rapid pace in sensor development has been accentuated by vast improvements in data analysis methods in the form of machine learning and artificial intelligence that, together, promise fantastic opportunities in chronic sensing of biosignals to enable preventative screening, automated diagnosis, and tools for personalized treatment strategies. At the same time, the importance of widely accessible personal monitoring has become evident by recent events such as the COVID-19 pandemic. Progress in fully integrated and chronic sensing solutions is therefore increasingly important. Chronic operation, however, is not truly possible with tethered approaches or bulky, battery-powered systems that require frequent user interaction. A solution for this integration challenge is offered by wireless and battery-free platforms that enable continuous collection of biosignals. This review summarizes current approaches to realize such device architectures and discusses their building blocks. Specifically, power supplies, wireless communication methods and compatible sensing modalities in the context of most prevalent implementations in target organ systems. Additionally, we highlight examples of current embodiments that quantitively expand sensing capabilities because of their use of wireless and battery-free architectures.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Le Cai
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Department of Electrical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Bio5 Institute, University of Arizona, Tucson, AZ, 85721, USA; Neuroscience GIDP, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
49
|
Kim I, Lee SG, Nam YH, Lee JH. Investigation on Wireless Link for Medical Telemetry Including Impedance Matching of Implanted Antennas. SENSORS 2021; 21:s21041431. [PMID: 33670691 PMCID: PMC7922892 DOI: 10.3390/s21041431] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 02/15/2021] [Accepted: 02/17/2021] [Indexed: 11/26/2022]
Abstract
The development of biomedical devices benefits patients by offering real-time healthcare. In particular, pacemakers have gained a great deal of attention because they offer opportunities for monitoring the patient’s vitals and biological statics in real time. One of the important factors in realizing real-time body-centric sensing is to establish a robust wireless communication link among the medical devices. In this paper, radio transmission and the optimal characteristics for impedance matching the medical telemetry of an implant are investigated. For radio transmission, an integral coupling formula based on 3D vector far-field patterns was firstly applied to compute the antenna coupling between two antennas placed inside and outside of the body. The formula provides the capability for computing the antenna coupling in the near-field and far-field region. In order to include the effects of human implantation, the far-field pattern was characterized taking into account a sphere enclosing an antenna made of human tissue. Furthermore, the characteristics of impedance matching inside the human body were studied by means of inherent wave impedances of electrical and magnetic dipoles. Here, we demonstrate that the implantation of a magnetic dipole is advantageous because it provides similar impedance characteristics to those of the human body.
Collapse
Affiliation(s)
- Ilkyu Kim
- C4I Team, Defense Agency Technology and Quality, Jinju 52851, Korea;
| | - Sun-Gyu Lee
- Department of Electronics and Electrical Engineering, Hongik University, Seoul 04066, Korea; (S.-G.L.); (Y.-H.N.)
| | - Yong-Hyun Nam
- Department of Electronics and Electrical Engineering, Hongik University, Seoul 04066, Korea; (S.-G.L.); (Y.-H.N.)
| | - Jeong-Hae Lee
- Department of Electronics and Electrical Engineering, Hongik University, Seoul 04066, Korea; (S.-G.L.); (Y.-H.N.)
- Correspondence:
| |
Collapse
|
50
|
Hosseini E, Dervin S, Ganguly P, Dahiya R. Biodegradable Materials for Sustainable Health Monitoring Devices. ACS APPLIED BIO MATERIALS 2021; 4:163-194. [PMID: 33842859 PMCID: PMC8022537 DOI: 10.1021/acsabm.0c01139] [Citation(s) in RCA: 62] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 12/20/2020] [Indexed: 12/12/2022]
Abstract
The recent advent of biodegradable materials has offered huge opportunity to transform healthcare technologies by enabling sensors that degrade naturally after use. The implantable electronic systems made from such materials eliminate the need for extraction or reoperation, minimize chronic inflammatory responses, and hence offer attractive propositions for future biomedical technology. The eco-friendly sensor systems developed from degradable materials could also help mitigate some of the major environmental issues by reducing the volume of electronic or medical waste produced and, in turn, the carbon footprint. With this background, herein we present a comprehensive overview of the structural and functional biodegradable materials that have been used for various biodegradable or bioresorbable electronic devices. The discussion focuses on the dissolution rates and degradation mechanisms of materials such as natural and synthetic polymers, organic or inorganic semiconductors, and hydrolyzable metals. The recent trend and examples of biodegradable or bioresorbable materials-based sensors for body monitoring, diagnostic, and medical therapeutic applications are also presented. Lastly, key technological challenges are discussed for clinical application of biodegradable sensors, particularly for implantable devices with wireless data and power transfer. Promising perspectives for the advancement of future generation of biodegradable sensor systems are also presented.
Collapse
Affiliation(s)
- Ensieh
S. Hosseini
- Bendable Electronics and
Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, G12 8QQ Glasgow, U.K.
| | - Saoirse Dervin
- Bendable Electronics and
Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, G12 8QQ Glasgow, U.K.
| | - Priyanka Ganguly
- Bendable Electronics and
Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, G12 8QQ Glasgow, U.K.
| | - Ravinder Dahiya
- Bendable Electronics and
Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, G12 8QQ Glasgow, U.K.
| |
Collapse
|