1
|
Baklouti S, Chaker A, Rezgui T, Sahbani A, Bennour S, Laribi MA. A Novel IMU-Based System for Work-Related Musculoskeletal Disorders Risk Assessment. SENSORS (BASEL, SWITZERLAND) 2024; 24:3419. [PMID: 38894211 PMCID: PMC11174619 DOI: 10.3390/s24113419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/18/2024] [Accepted: 05/24/2024] [Indexed: 06/21/2024]
Abstract
This study introduces a novel wearable Inertial Measurement Unit (IMU)-based system for an objective and comprehensive assessment of Work-Related Musculoskeletal Disorders (WMSDs), thus enhancing workplace safety. The system integrates wearable technology with a user-friendly interface, providing magnetometer-free orientation estimation, joint angle measurements, and WMSDs risk evaluation. Tested in a cable manufacturing facility, the system was evaluated with ten female employees. The evaluation involved work cycle identification, inter-subject comparisons, and benchmarking against standard WMSD risk assessments like RULA, REBA, Strain Index, and Rodgers Muscle Fatigue Analysis. The evaluation demonstrated uniform joint patterns across participants (ICC=0.72±0.23) and revealed a higher occurrence of postures warranting further investigation, which is not easily detected by traditional methods such as RULA. The experimental results showed that the proposed system's risk assessments closely aligned with the established methods and enabled detailed and targeted risk assessments, pinpointing specific bodily areas for immediate ergonomic interventions. This approach not only enhances the detection of ergonomic risks but also supports the development of personalized intervention strategies, addressing common workplace issues such as tendinitis, low back pain, and carpal tunnel syndrome. The outcomes highlight the system's sensitivity and specificity in identifying ergonomic hazards. Future efforts should focus on broader validation and exploring the relative influence of various WMSDs risk factors to refine risk assessment and intervention strategies for improved applicability in occupational health.
Collapse
Affiliation(s)
- Souha Baklouti
- Mechanical Laboratory of Sousse (LMS), National School of Engineers of Sousse, University of Sousse, Sousse 4023, Tunisia; (S.B.); (A.C.); (S.B.)
- ENOVA Robotics S.A., Novation City, Sousse 4023, Tunisia;
| | - Abdelbadia Chaker
- Mechanical Laboratory of Sousse (LMS), National School of Engineers of Sousse, University of Sousse, Sousse 4023, Tunisia; (S.B.); (A.C.); (S.B.)
| | - Taysir Rezgui
- Applied Mechanics, and Systems Research Laboratory (LASMAP), Tunisia Polytechnic School, University of Carthage, Tunis 2078, Tunisia;
| | - Anis Sahbani
- ENOVA Robotics S.A., Novation City, Sousse 4023, Tunisia;
- Institute for Intelligent Systems and Robotics (ISIR), CNRS, Sorbonne University, 75006 Paris, France
| | - Sami Bennour
- Mechanical Laboratory of Sousse (LMS), National School of Engineers of Sousse, University of Sousse, Sousse 4023, Tunisia; (S.B.); (A.C.); (S.B.)
| | - Med Amine Laribi
- Mechanical Laboratory of Sousse (LMS), National School of Engineers of Sousse, University of Sousse, Sousse 4023, Tunisia; (S.B.); (A.C.); (S.B.)
- Department of GMSC, Pprime Institute CNRS, University of Poitiers, UPR 3346, 86073 Poitiers, France
| |
Collapse
|
2
|
De Pasquale P, Bonanno M, Mojdehdehbaher S, Quartarone A, Calabrò RS. The Use of Head-Mounted Display Systems for Upper Limb Kinematic Analysis in Post-Stroke Patients: A Perspective Review on Benefits, Challenges and Other Solutions. Bioengineering (Basel) 2024; 11:538. [PMID: 38927774 PMCID: PMC11200415 DOI: 10.3390/bioengineering11060538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/20/2024] [Accepted: 05/21/2024] [Indexed: 06/28/2024] Open
Abstract
In recent years, there has been a notable increase in the clinical adoption of instrumental upper limb kinematic assessment. This trend aligns with the rising prevalence of cerebrovascular impairments, one of the most prevalent neurological disorders. Indeed, there is a growing need for more objective outcomes to facilitate tailored rehabilitation interventions following stroke. Emerging technologies, like head-mounted virtual reality (HMD-VR) platforms, have responded to this demand by integrating diverse tracking methodologies. Specifically, HMD-VR technology enables the comprehensive tracking of body posture, encompassing hand position and gesture, facilitated either through specific tracker placements or via integrated cameras coupled with sophisticated computer graphics algorithms embedded within the helmet. This review aims to present the state-of-the-art applications of HMD-VR platforms for kinematic analysis of the upper limb in post-stroke patients, comparing them with conventional tracking systems. Additionally, we address the potential benefits and challenges associated with these platforms. These systems might represent a promising avenue for safe, cost-effective, and portable objective motor assessment within the field of neurorehabilitation, although other systems, including robots, should be taken into consideration.
Collapse
Affiliation(s)
- Paolo De Pasquale
- IRCCS Centro Neurolesi Bonino-Pulejo, Cda Casazza, SS 113, 98124 Messina, Italy; (P.D.P.); (A.Q.); (R.S.C.)
| | - Mirjam Bonanno
- IRCCS Centro Neurolesi Bonino-Pulejo, Cda Casazza, SS 113, 98124 Messina, Italy; (P.D.P.); (A.Q.); (R.S.C.)
| | - Sepehr Mojdehdehbaher
- Department of Mathematics, Computer Science, Physics and Earth Sciences (MIFT), University of Messina, Viale Ferdinando Stagno d’Alcontres, 31, 98166 Messina, Italy;
| | - Angelo Quartarone
- IRCCS Centro Neurolesi Bonino-Pulejo, Cda Casazza, SS 113, 98124 Messina, Italy; (P.D.P.); (A.Q.); (R.S.C.)
| | - Rocco Salvatore Calabrò
- IRCCS Centro Neurolesi Bonino-Pulejo, Cda Casazza, SS 113, 98124 Messina, Italy; (P.D.P.); (A.Q.); (R.S.C.)
| |
Collapse
|
3
|
Seong M, Kim G, Yeo D, Kang Y, Yang H, DelPreto J, Matusik W, Rus D, Kim S. MultiSenseBadminton: Wearable Sensor-Based Biomechanical Dataset for Evaluation of Badminton Performance. Sci Data 2024; 11:343. [PMID: 38580698 PMCID: PMC10997636 DOI: 10.1038/s41597-024-03144-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 03/14/2024] [Indexed: 04/07/2024] Open
Abstract
The sports industry is witnessing an increasing trend of utilizing multiple synchronized sensors for player data collection, enabling personalized training systems with multi-perspective real-time feedback. Badminton could benefit from these various sensors, but there is a scarcity of comprehensive badminton action datasets for analysis and training feedback. Addressing this gap, this paper introduces a multi-sensor badminton dataset for forehand clear and backhand drive strokes, based on interviews with coaches for optimal usability. The dataset covers various skill levels, including beginners, intermediates, and experts, providing resources for understanding biomechanics across skill levels. It encompasses 7,763 badminton swing data from 25 players, featuring sensor data on eye tracking, body tracking, muscle signals, and foot pressure. The dataset also includes video recordings, detailed annotations on stroke type, skill level, sound, ball landing, and hitting location, as well as survey and interview data. We validated our dataset by applying a proof-of-concept machine learning model to all annotation data, demonstrating its comprehensive applicability in advanced badminton training and research.
Collapse
Affiliation(s)
- Minwoo Seong
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea
| | - Gwangbin Kim
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea
| | - Dohyeon Yeo
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea
| | - Yumin Kang
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea
| | - Heesan Yang
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea
| | - Joseph DelPreto
- Massachusetts Institute of Technology, CSAIL, Cambridge, MA, 02139, USA
| | - Wojciech Matusik
- Massachusetts Institute of Technology, CSAIL, Cambridge, MA, 02139, USA
| | - Daniela Rus
- Massachusetts Institute of Technology, CSAIL, Cambridge, MA, 02139, USA
| | - SeungJun Kim
- Gwangju Institute of Science and Technology, School of Integrated Technology, Gwangju, 61005, South Korea.
| |
Collapse
|
4
|
Han SL, Cai ML, Pan MC. Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects. SENSORS (BASEL, SWITZERLAND) 2024; 24:1519. [PMID: 38475055 DOI: 10.3390/s24051519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 02/14/2024] [Accepted: 02/21/2024] [Indexed: 03/14/2024]
Abstract
The study aims to construct an inertial measuring system for the application of amputee subjects wearing a prosthesis. A new computation scheme to process inertial data by installing seven wireless inertial sensors on the lower limbs was implemented and validated by comparing it with an optical motion capture system. We applied this system to amputees to verify its performance for gait analysis. The gait parameters are evaluated to objectively assess the amputees' prosthesis-wearing status. The Madgwick algorithm was used in the study to correct the angular velocity deviation using acceleration data and convert it to quaternion. Further, the zero-velocity update method was applied to reconstruct patients' walking trajectories. The combination of computed walking trajectory with pelvic and lower limb joint motion enables sketching the details of motion via a stickman that helps visualize and animate the walk and gait of a test subject. Five participants with above-knee (n = 2) and below-knee (n = 3) amputations were recruited for gait analysis. Kinematic parameters were evaluated during a walking test to assess joint alignment and overall gait characteristics. Our findings support the feasibility of employing simple algorithms to achieve accurate and precise joint angle estimation and gait parameters based on wireless inertial sensor data.
Collapse
Affiliation(s)
- Shao-Li Han
- Department of Mechanical Engineering, National Central University, Taoyuan 32001, Taiwan
- Department of Physical Medicine and Rehabilitation, Changhua Christian Hospital, Changhua 500209, Taiwan
| | - Meng-Lin Cai
- Department of Mechanical Engineering, National Central University, Taoyuan 32001, Taiwan
| | - Min-Chun Pan
- Department of Mechanical Engineering, National Central University, Taoyuan 32001, Taiwan
| |
Collapse
|
5
|
Li D, Hallack A, Gwilym S, Li D, Hu MT, Cantley J. Investigating gait-responsive somatosensory cueing from a wearable device to improve walking in Parkinson's disease. Biomed Eng Online 2023; 22:108. [PMID: 37974260 PMCID: PMC10652624 DOI: 10.1186/s12938-023-01167-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 10/20/2023] [Indexed: 11/19/2023] Open
Abstract
Freezing-of-gait (FOG) and impaired walking are common features of Parkinson's disease (PD). Provision of external stimuli (cueing) can improve gait, however, many cueing methods are simplistic, increase task loading or have limited utility in a real-world setting. Closed-loop (automated) somatosensory cueing systems have the potential to deliver personalised, discrete cues at the appropriate time, without requiring user input. Further development of cue delivery methods and FOG-detection are required to achieve this. In this feasibility study, we aimed to test if FOG-initiated vibration cues applied to the lower-leg via wearable devices can improve gait in PD, and to develop real-time FOG-detection algorithms. 17 participants with Parkinson's disease and daily FOG were recruited. During 1 h study sessions, participants undertook 4 complex walking circuits, each with a different intervention: continuous rhythmic vibration cueing (CC), responsive cueing (RC; cues initiated by the research team in response to FOG), device worn with no cueing (NC), or no device (ND). Study sessions were grouped into 3 stages/blocks (A-C), separated by a gap of several weeks, enabling improvements to circuit design and the cueing device to be implemented. Video and onboard inertial measurement unit (IMU) data were analyzed for FOG events and gait metrics. RC significantly improved circuit completion times demonstrating improved overall performance across a range of walking activities. Step frequency was significantly enhanced by RC during stages B and C. During stage C, > 10 FOG events were recorded in 45% of participants without cueing (NC), which was significantly reduced by RC. A machine learning framework achieved 83% sensitivity and 80% specificity for FOG detection using IMU data. Together, these data support the feasibility of closed-loop cueing approaches coupling real-time FOG detection with responsive somatosensory lower-leg cueing to improve gait in PD.
Collapse
Affiliation(s)
- Dongli Li
- Department of Physiology, Anatomy and Genetics, University of Oxford, Sherrington Building, Parks Road, Oxford, OX2 3PT, UK
| | - Andre Hallack
- Department of Physiology, Anatomy and Genetics, University of Oxford, Sherrington Building, Parks Road, Oxford, OX2 3PT, UK
| | - Sophie Gwilym
- Oxfordshire Neurophysiotherapy, The Bosworth Clinic, Quarry Court, Bell Lane, Cassington, OX29 4DS, UK
| | - Dongcheng Li
- Department of Computer Science, University of Texas at Dallas, Richardson, TX, 75082, USA
| | - Michele T Hu
- Oxford Parkinson's Disease Centre, University of Oxford, Oxford, UK
- Nuffield Department of Clinical Neurosciences, Division of Neurology, University of Oxford, Oxford, Oxfordshire, UK
| | - James Cantley
- Department of Physiology, Anatomy and Genetics, University of Oxford, Sherrington Building, Parks Road, Oxford, OX2 3PT, UK.
- Division of Systems Medicine, Ninewells Hospital & Medical School, University of Dundee, James Arrott Drive, Dundee, DD1 9SY, UK.
| |
Collapse
|
6
|
Jayasinghe U, Hwang F, Harwin WS. Inertial measurement data from loose clothing worn on the lower body during everyday activities. Sci Data 2023; 10:709. [PMID: 37848448 PMCID: PMC10582085 DOI: 10.1038/s41597-023-02567-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 09/13/2023] [Indexed: 10/19/2023] Open
Abstract
Embedding sensors into clothing is promising as a way for people to wear multiple sensors easily, for applications such as long-term activity monitoring. To our knowledge, this is the first published dataset collected from sensors in loose clothing. 6 Inertial Measurement Units (IMUs) were configured as a 'sensor string' and attached to casual trousers such that there were three sensors on each leg near the waist, thigh, and ankle/lower-shank. Participants also wore an Actigraph accelerometer on their dominant wrist. The dataset consists of 15 participant-days worth of data collected from 5 healthy adults (age range: 28-48 years, 3 males and 2 females). Each participant wore the clothes with sensors for between 1 and 4 days for 5-8 hours per day. Each day, data were collected while participants completed a fixed circuit of activities (with a video ground truth) as well as during free day-to-day activities (with a diary). This dataset can be used to analyse human movements, transitional movements, and postural changes based on a range of features.
Collapse
Affiliation(s)
- Udeni Jayasinghe
- Biomedical Engineering Section, University of Reading, RG6 6DH, Reading, UK.
| | - Faustina Hwang
- Biomedical Engineering Section, University of Reading, RG6 6DH, Reading, UK
| | - William S Harwin
- Biomedical Engineering Section, University of Reading, RG6 6DH, Reading, UK
| |
Collapse
|
7
|
Zhou L, Fischer E, Brahms CM, Granacher U, Arnrich B. DUO-GAIT: A gait dataset for walking under dual-task and fatigue conditions with inertial measurement units. Sci Data 2023; 10:543. [PMID: 37604913 PMCID: PMC10442385 DOI: 10.1038/s41597-023-02391-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 07/17/2023] [Indexed: 08/23/2023] Open
Abstract
In recent years, there has been a growing interest in developing and evaluating gait analysis algorithms based on inertial measurement unit (IMU) data, which has important implications, including sports, assessment of diseases, and rehabilitation. Multi-tasking and physical fatigue are two relevant aspects of daily life gait monitoring, but there is a lack of publicly available datasets to support the development and testing of methods using a mobile IMU setup. We present a dataset consisting of 6-minute walks under single- (only walking) and dual-task (walking while performing a cognitive task) conditions in unfatigued and fatigued states from sixteen healthy adults. Especially, nine IMUs were placed on the head, chest, lower back, wrists, legs, and feet to record under each of the above-mentioned conditions. The dataset also includes a rich set of spatio-temporal gait parameters that capture the aspects of pace, symmetry, and variability, as well as additional study-related information to support further analysis. This dataset can serve as a foundation for future research on gait monitoring in free-living environments.
Collapse
Affiliation(s)
- Lin Zhou
- Digital Health - Connected Healthcare, Hasso Plattner Institute, University of Potsdam, Potsdam, 14482, Germany.
| | - Eric Fischer
- Digital Health - Connected Healthcare, Hasso Plattner Institute, University of Potsdam, Potsdam, 14482, Germany
| | - Clemens Markus Brahms
- Division of Training and Movement Sciences, University of Potsdam, 14469, Potsdam, Germany
- Department of Sport and Sport Science, Exercise and Human Movement Science, University of Freiburg, 79102, Freiburg, Germany
| | - Urs Granacher
- Department of Sport and Sport Science, Exercise and Human Movement Science, University of Freiburg, 79102, Freiburg, Germany
| | - Bert Arnrich
- Digital Health - Connected Healthcare, Hasso Plattner Institute, University of Potsdam, Potsdam, 14482, Germany.
| |
Collapse
|
8
|
Castro Aguiar R, Sam Jeeva Raj EJ, Chakrabarty S. Simplified Markerless Stride Detection Pipeline (sMaSDP) for Surface EMG Segmentation. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094340. [PMID: 37177543 PMCID: PMC10181504 DOI: 10.3390/s23094340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/19/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023]
Abstract
To diagnose mobility impairments and select appropriate physiotherapy, gait assessment studies are often recommended. These studies are usually conducted in confined clinical settings, which may feel foreign to a subject and affect their motivation, coordination, and overall mobility. Conducting gait studies in unconstrained natural settings instead, such as the subject's Activities of Daily Life (ADL), could provide a more accurate assessment. To appropriately diagnose gait deficiencies, muscle activity should be recorded in parallel with typical kinematic studies. To achieve this, Electromyography (EMG) and kinematic are collected synchronously. Our protocol sMaSDP introduces a simplified markerless gait event detection pipeline for the segmentation of EMG signals via Inertial Measurement Unit (IMU) data, based on a publicly available dataset. This methodology intends to provide a simple, detailed sequence of processing steps for gait event detection via IMU and EMG, and serves as tutorial for beginners in unconstrained gait assessment studies. In an unconstrained gait experiment, 10 healthy subjects walk through a course designed to mimic everyday walking, with their kinematic and EMG data recorded, for a total of 20 trials. Five different walking modalities, such as level walking, ramp up/down, and staircase up/down are included. By segmenting and filtering the data, we generate an algorithm that detects heel-strike events, using a single IMU, and isolates EMG activity of gait cycles. Applicable to different datasets, sMaSDP was tested in healthy gait and gait data of Parkinson's Disease (PD) patients. Using sMaSDP, we extracted muscle activity in healthy walking and identified heel-strike events in PD patient data. The algorithm parameters, such as expected velocity and cadence, are adjustable and can further improve the detection accuracy, and our emphasis on the wearable technologies makes this solution ideal for ADL gait studies.
Collapse
Affiliation(s)
- Rafael Castro Aguiar
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| | | | - Samit Chakrabarty
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| |
Collapse
|
9
|
Young F, Mason R, Morris RE, Stuart S, Godfrey A. IoT-Enabled Gait Assessment: The Next Step for Habitual Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:4100. [PMID: 37112441 PMCID: PMC10144082 DOI: 10.3390/s23084100] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/13/2023] [Accepted: 04/17/2023] [Indexed: 06/19/2023]
Abstract
Walking/gait quality is a useful clinical tool to assess general health and is now broadly described as the sixth vital sign. This has been mediated by advances in sensing technology, including instrumented walkways and three-dimensional motion capture. However, it is wearable technology innovation that has spawned the highest growth in instrumented gait assessment due to the capabilities for monitoring within and beyond the laboratory. Specifically, instrumented gait assessment with wearable inertial measurement units (IMUs) has provided more readily deployable devices for use in any environment. Contemporary IMU-based gait assessment research has shown evidence of the robust quantifying of important clinical gait outcomes in, e.g., neurological disorders to gather more insightful habitual data in the home and community, given the relatively low cost and portability of IMUs. The aim of this narrative review is to describe the ongoing research regarding the need to move gait assessment out of bespoke settings into habitual environments and to consider the shortcomings and inefficiencies that are common within the field. Accordingly, we broadly explore how the Internet of Things (IoT) could better enable routine gait assessment beyond bespoke settings. As IMU-based wearables and algorithms mature in their corroboration with alternate technologies, such as computer vision, edge computing, and pose estimation, the role of IoT communication will enable new opportunities for remote gait assessment.
Collapse
Affiliation(s)
- Fraser Young
- Department of Computer and Information Sciences, Northumbria University, Newcastle-upon-Tyne NE1 8ST, UK
| | - Rachel Mason
- Department of Health and Life Sciences, Northumbria University, Newcastle-upon-Tyne NE1 8ST, UK
| | - Rosie E. Morris
- Department of Health and Life Sciences, Northumbria University, Newcastle-upon-Tyne NE1 8ST, UK
| | - Samuel Stuart
- Department of Health and Life Sciences, Northumbria University, Newcastle-upon-Tyne NE1 8ST, UK
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle-upon-Tyne NE1 8ST, UK
| |
Collapse
|
10
|
Moeller T, Moehler F, Krell-Roesch J, Dežman M, Marquardt C, Asfour T, Stein T, Woll A. Use of Lower Limb Exoskeletons as an Assessment Tool for Human Motor Performance: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:3032. [PMID: 36991743 PMCID: PMC10057915 DOI: 10.3390/s23063032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 06/19/2023]
Abstract
Exoskeletons are a promising tool to support individuals with a decreased level of motor performance. Due to their built-in sensors, exoskeletons offer the possibility of continuously recording and assessing user data, for example, related to motor performance. The aim of this article is to provide an overview of studies that rely on using exoskeletons to measure motor performance. Therefore, we conducted a systematic literature review, following the PRISMA Statement guidelines. A total of 49 studies using lower limb exoskeletons for the assessment of human motor performance were included. Of these, 19 studies were validity studies, and six were reliability studies. We found 33 different exoskeletons; seven can be considered stationary, and 26 were mobile exoskeletons. The majority of the studies measured parameters such as range of motion, muscle strength, gait parameters, spasticity, and proprioception. We conclude that exoskeletons can be used to measure a wide range of motor performance parameters through built-in sensors, and seem to be more objective and specific than manual test procedures. However, since these parameters are usually estimated from built-in sensor data, the quality and specificity of an exoskeleton to assess certain motor performance parameters must be examined before an exoskeleton can be used, for example, in a research or clinical setting.
Collapse
Affiliation(s)
- Tobias Moeller
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Felix Moehler
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Janina Krell-Roesch
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Miha Dežman
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Charlotte Marquardt
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Tamim Asfour
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Thorsten Stein
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Alexander Woll
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| |
Collapse
|
11
|
Spilz A, Munz M. Synchronisation of wearable inertial measurement units based on magnetometer data. BIOMED ENG-BIOMED TE 2023:bmt-2021-0329. [PMID: 36668676 DOI: 10.1515/bmt-2021-0329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 12/27/2022] [Indexed: 01/22/2023]
Abstract
OBJECTIVES Synchronisation of wireless inertial measurement units in human movement analysis is often achieved using event-based synchronisation techniques. However, these techniques lack precise event generation and accuracy. An inaccurate synchronisation could lead to large errors in motion estimation and reconstruction and therefore wrong analysis outputs. METHODS We propose a novel event-based synchronisation technique based on a magnetic field, which allows sub-sample accuracy. A setup featuring Shimmer3 inertial measurement units is designed to test the approach. RESULTS The proposed technique shows to be able to synchronise with a maximum offset of below 2.6 ms with sensors measuring at 100 Hz. The investigated parameters suggest a required synchronisation time of 8 s. CONCLUSIONS The results indicate a reliable event generation and detection for synchronisation of wireless inertial measurement units. Further research should investigate the temperature changes that the sensors are exposed to during human motion analysis and their influence on the internal time measurement of the sensors. In addition, the approach should be tested using inertial measurement units from different manufacturers to investigate an identified constant offset in the accuracy measurements.
Collapse
Affiliation(s)
- Andreas Spilz
- Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, University of Applied Sciences, Ulm, Germany
| | - Michael Munz
- Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, University of Applied Sciences, Ulm, Germany
| |
Collapse
|
12
|
Ortigas Vásquez A, Maas A, List R, Schütz P, Taylor WR, Grupp TM. A Framework for Analytical Validation of Inertial-Sensor-Based Knee Kinematics Using a Six-Degrees-of-Freedom Joint Simulator. SENSORS (BASEL, SWITZERLAND) 2022; 23:348. [PMID: 36616945 PMCID: PMC9824828 DOI: 10.3390/s23010348] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/23/2022] [Accepted: 12/24/2022] [Indexed: 06/16/2023]
Abstract
The success of kinematic analysis that relies on inertial measurement units (IMUs) heavily depends on the performance of the underlying algorithms. Quantifying the level of uncertainty associated with the models and approximations implemented within these algorithms, without the complication of soft-tissue artefact, is therefore critical. To this end, this study aimed to assess the rotational errors associated with controlled movements. Here, data of six total knee arthroplasty patients from a previously published fluoroscopy study were used to simulate realistic kinematics of daily activities using IMUs mounted to a six-degrees-of-freedom joint simulator. A model-based method involving extended Kalman filtering to derive rotational kinematics from inertial measurements was tested and compared against the ground truth simulator values. The algorithm demonstrated excellent accuracy (root-mean-square error ≤0.9°, maximum absolute error ≤3.2°) in estimating three-dimensional rotational knee kinematics during level walking. Although maximum absolute errors linked to stair descent and sit-to-stand-to-sit rose to 5.2° and 10.8°, respectively, root-mean-square errors peaked at 1.9° and 7.5°. This study hereby describes an accurate framework for evaluating the suitability of the underlying kinematic models and assumptions of an IMU-based motion analysis system, facilitating the future validation of analogous tools.
Collapse
Affiliation(s)
- Ariana Ortigas Vásquez
- Research and Development, Aesculap AG, 78532 Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Ludwig Maximilians University Munich, 81377 Munich, Germany
| | - Allan Maas
- Research and Development, Aesculap AG, 78532 Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Ludwig Maximilians University Munich, 81377 Munich, Germany
| | - Renate List
- Human Performance Lab., Schulthess Clinic, 8008 Zurich, Switzerland
| | - Pascal Schütz
- Institute for Biomechanics, ETH Zurich, Leopold-Ruzicka-Weg 4, 8093 Zurich, Switzerland
| | - William R. Taylor
- Institute for Biomechanics, ETH Zurich, Leopold-Ruzicka-Weg 4, 8093 Zurich, Switzerland
| | - Thomas M. Grupp
- Research and Development, Aesculap AG, 78532 Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Ludwig Maximilians University Munich, 81377 Munich, Germany
| |
Collapse
|
13
|
Uno Y, Ogasawara I, Konda S, Yoshida N, Otsuka N, Kikukawa Y, Tsujii A, Nakata K. Validity of Spatio-Temporal Gait Parameters in Healthy Young Adults Using a Motion-Sensor-Based Gait Analysis System (ORPHE ANALYTICS) during Walking and Running. SENSORS (BASEL, SWITZERLAND) 2022; 23:s23010331. [PMID: 36616928 PMCID: PMC9823871 DOI: 10.3390/s23010331] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 12/13/2022] [Accepted: 12/23/2022] [Indexed: 05/25/2023]
Abstract
Motion sensors are widely used for gait analysis. The validity of commercial gait analysis systems is of great interest because calculating position/angle-level gait parameters potentially produces an error in the integration process of the motion sensor data; moreover, the validity of ORPHE ANALYTICS, a motion-sensor-based gait analysis system, has not yet been examined. We examined the validity of the gait parameters calculated using ORPHE ANALYTICS relative to those calculated using conventional optical motion capture. Nine young adults performed gait tasks on a treadmill at speeds of 2−12 km/h. The three-dimensional position data and acceleration and angular velocity data of the feet were collected. The gait parameters were calculated from motion sensor data using ORPHE ANALYTICS, and optical motion capture data. Intraclass correlation coefficients [ICC(2,1)] were calculated for relative validities. Eight items, namely, stride duration, stride length, stride frequency, stride speed, vertical height, stance phase duration, swing phase duration, and sagittal angleIC exhibited excellent relative validities [ICC(2,1) > 0.9]. In contrast, sagittal angleTO and frontal angleIC demonstrated good [ICC(2,1) = 0.892−0.833] and moderate relative validity [ICC(2,1) = 0.566−0.627], respectively. ORPHE ANALYTICS was found to exhibit excellent relative validities for most gait parameters. These results suggest its feasibility for gait analysis outside the laboratory setting.
Collapse
Affiliation(s)
- Yuki Uno
- Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
- ORPHE Inc., Shibuya 151-0053, Tokyo, Japan
| | - Issei Ogasawara
- Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
- Department of Sports Medical Biomechanics, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
| | - Shoji Konda
- Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
- Department of Sports Medical Biomechanics, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
| | - Natsuki Yoshida
- Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
| | | | | | - Akira Tsujii
- Department of Sports Medical Biomechanics, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
| | - Ken Nakata
- Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Suita 565-0871, Osaka, Japan
| |
Collapse
|
14
|
Can Wearable Inertial Measurement Units Be Used to Measure Sleep Biomechanics? Establishing Initial Feasibility and Validity. Biomimetics (Basel) 2022; 8:biomimetics8010002. [PMID: 36648788 PMCID: PMC9844380 DOI: 10.3390/biomimetics8010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022] Open
Abstract
Wearable motion sensors, specifically, Inertial Measurement Units, are useful tools for the assessment of orientation and movement during sleep. The DOTs platform (Xsens, Enschede, The Netherlands) has shown promise for this purpose. This pilot study aimed to assess its feasibility and validity for recording sleep biomechanics. Feasibility was assessed using four metrics: Drift, Battery Life, Reliability of Recording, and Participant Comfort. Each metric was rated as Stop (least successful), Continue But Modify Protocol, Continue But Monitor Closely, or Continue Without Modifications (most successful). A convenience sample of ten adults slept for one night with a DOT unit attached to their sternum, abdomen, and left and right legs. A survey was administered the following day to assess participant comfort wearing the DOTs. A subset of five participants underwent a single evaluation in a Vicon (Oxford Metrics, Oxford, UK) motion analysis lab to assess XSENS DOTs’ validity. With the two systems recording simultaneously, participants were prompted through a series of movements intended to mimic typical sleep biomechanics (rolling over in lying), and the outputs of both systems were compared to assess the level of agreement. The DOT platform performed well on all metrics, with Drift, Battery Life, and Recording Reliability being rated as Continue Without Modifications. Participant Comfort was rated as Continue But Monitor Closely. The DOT Platform demonstrated an extremely high level of agreement with the Vicon motion analysis lab (difference of <0.025°). Using the Xsens DOT platform to assess sleep biomechanics is feasible and valid in adult populations. Future studies should further investigate the feasibility of using this data capture method for extended periods (e.g., multiple days) and in other groups (e.g., paediatric populations).
Collapse
|
15
|
Fercho J, Krakowiak M, Yuser R, Szmuda T, Zieliński P, Szarek D, Pettersson SD, Miękisiak G. Evaluation of Movement Restriction of Spinal Orthoses Using Inertial Measurement Units. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:16515. [PMID: 36554395 PMCID: PMC9779723 DOI: 10.3390/ijerph192416515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/05/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
Despite the frequent use of orthopedic braces or spine stabilizers in diseases such as kyphosis, lordosis, and scoliosis, as well as in the case of injuries and rehabilitation after surgeries, there is no clear evidence of their proper stabilization of the spine while carrying out daily activities. This study sought to assess the spine's mobility while wearing three different orthopedic braces while performing basic tasks. Ten healthy subjects were enrolled. Three Inertial Measurement Units (IMUs) were attached superficially along the spine at approximate levels: cervical (C7), between thoracic (T8) and lumbar (L3), and sacrum. The angle between sensors was monitored to provide data on the sagittal profile. In addition, the displacement of the spine's longitudinal axis was measured (rotation). There are three types of orthopedic braces: the semi-rigid Hohmann corset, the Jewett brace, and the Thoracolumbar Fixed Spinal Orthosis (TLSO). Four tasks were monitored: standing, sitting, walking, and picking up an item from the floor with one hand. All braces provided a similar level of stability in both the sagittal plane and rotational axis while lifting an object. On the other hand, while walking and sitting, the TLSO was the only orthosis providing a statistically significant rigidity in the sagittal plane. When performing a more voluntary task, the measured rigidity of softer braces was significantly increased when compared with more involuntary tasks. A certain degree of motion restriction with spinal orthoses may come from the feedback pressure, which stimulates paraspinal muscles to contract and thus increases the overall rigidity of the trunk.
Collapse
Affiliation(s)
- Justyna Fercho
- Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | - Michał Krakowiak
- Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | - Rami Yuser
- Scientific Circle of Neurology and Neurosurgery, Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | - Tomasz Szmuda
- Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | - Piotr Zieliński
- Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | - Dariusz Szarek
- Department of Neurosurgery, Marciniak’s Hospital, 54-049 Wrocław, Poland
| | - Samuel D. Pettersson
- Scientific Circle of Neurology and Neurosurgery, Neurosurgery Department, Medical University of Gdansk, 80-214 Gdańsk, Poland
| | | |
Collapse
|
16
|
Hamilton RI, Williams J, Holt C. Biomechanics beyond the lab: Remote technology for osteoarthritis patient data-A scoping review. FRONTIERS IN REHABILITATION SCIENCES 2022; 3:1005000. [PMID: 36451804 PMCID: PMC9701737 DOI: 10.3389/fresc.2022.1005000] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/05/2022] [Indexed: 01/14/2024]
Abstract
The objective of this project is to produce a review of available and validated technologies suitable for gathering biomechanical and functional research data in patients with osteoarthritis (OA), outside of a traditionally fixed laboratory setting. A scoping review was conducted using defined search terms across three databases (Scopus, Ovid MEDLINE, and PEDro), and additional sources of information from grey literature were added. One author carried out an initial title and abstract review, and two authors independently completed full-text screenings. Out of the total 5,164 articles screened, 75 were included based on inclusion criteria covering a range of technologies in articles published from 2015. These were subsequently categorised by technology type, parameters measured, level of remoteness, and a separate table of commercially available systems. The results concluded that from the growing number of available and emerging technologies, there is a well-established range in use and further in development. Of particular note are the wide-ranging available inertial measurement unit systems and the breadth of technology available to record basic gait spatiotemporal measures with highly beneficial and informative functional outputs. With the majority of technologies categorised as suitable for part-remote use, the number of technologies that are usable and fully remote is rare and they usually employ smartphone software to enable this. With many systems being developed for camera-based technology, such technology is likely to increase in usability and availability as computational models are being developed with increased sensitivities to recognise patterns of movement, enabling data collection in the wider environment and reducing costs and creating a better understanding of OA patient biomechanical and functional movement data.
Collapse
Affiliation(s)
- Rebecca I. Hamilton
- Musculoskeletal Biomechanics Research Facility, School of Engineering, Cardiff University, Cardiff, United Kingdom
| | - Jenny Williams
- Musculoskeletal Biomechanics Research Facility, School of Engineering, Cardiff University, Cardiff, United Kingdom
| | | | - Cathy Holt
- Musculoskeletal Biomechanics Research Facility, School of Engineering, Cardiff University, Cardiff, United Kingdom
- Osteoarthritis Technology NetworkPlus (OATech+), EPSRC UK-Wide Research Network+, United Kingdom
| |
Collapse
|
17
|
Jacobsen NSJ, Blum S, Scanlon JEM, Witt K, Debener S. Mobile electroencephalography captures differences of walking over even and uneven terrain but not of single and dual-task gait. Front Sports Act Living 2022; 4:945341. [PMID: 36275441 PMCID: PMC9582531 DOI: 10.3389/fspor.2022.945341] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 09/13/2022] [Indexed: 11/09/2022] Open
Abstract
Walking on natural terrain while performing a dual-task, such as typing on a smartphone is a common behavior. Since dual-tasking and terrain change gait characteristics, it is of interest to understand how altered gait is reflected by changes in gait-associated neural signatures. A study was performed with 64-channel electroencephalography (EEG) of healthy volunteers, which was recorded while they walked over uneven and even terrain outdoors with and without performing a concurrent task (self-paced button pressing with both thumbs). Data from n = 19 participants (M = 24 years, 13 females) were analyzed regarding gait-phase related power modulations (GPM) and gait performance (stride time and stride time-variability). GPMs changed significantly with terrain, but not with the task. Descriptively, a greater beta power decrease following right-heel strikes was observed on uneven compared to even terrain. No evidence of an interaction was observed. Beta band power reduction following the initial contact of the right foot was more pronounced on uneven than on even terrain. Stride times were longer on uneven compared to even terrain and during dual- compared to single-task gait, but no significant interaction was observed. Stride time variability increased on uneven terrain compared to even terrain but not during single- compared to dual-tasking. The results reflect that as the terrain difficulty increases, the strides become slower and more irregular, whereas a secondary task slows stride duration only. Mobile EEG captures GPM differences linked to terrain changes, suggesting that the altered gait control demands and associated cortical processes can be identified. This and further studies may help to lay the foundation for protocols assessing the cognitive demand of natural gait on the motor system.
Collapse
Affiliation(s)
- Nadine Svenja Josée Jacobsen
- Neuropsychology Lab, Department of Psychology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany,*Correspondence: Nadine Svenja Josée Jacobsen
| | - Sarah Blum
- Neuropsychology Lab, Department of Psychology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany,Hörzentrum Oldenburg GmbH, Oldenburg, Germany,Cluster of Excellence Hearing4all, Oldenburg, Germany
| | - Joanna Elizabeth Mary Scanlon
- Neuropsychology Lab, Department of Psychology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany,Branch for Hearing, Speech and Audio Technology HSA, Fraunhofer Institute for Digital Media Technology IDMT, Oldenburg, Germany
| | - Karsten Witt
- Department of Neurology and Research Center Neurosensory Science, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany
| | - Stefan Debener
- Neuropsychology Lab, Department of Psychology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany,Cluster of Excellence Hearing4all, Oldenburg, Germany
| |
Collapse
|
18
|
Ghaffari A, Rahbek O, Lauritsen REK, Kappel A, Kold S, Rasmussen J. Criterion Validity of Linear Accelerations Measured with Low-Sampling-Frequency Accelerometers during Overground Walking in Elderly Patients with Knee Osteoarthritis. SENSORS (BASEL, SWITZERLAND) 2022; 22:5289. [PMID: 35890969 PMCID: PMC9322915 DOI: 10.3390/s22145289] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 07/08/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.
Collapse
Affiliation(s)
- Arash Ghaffari
- Interdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark; (O.R.); (R.E.K.L.); (A.K.); (S.K.)
| | - Ole Rahbek
- Interdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark; (O.R.); (R.E.K.L.); (A.K.); (S.K.)
| | | | - Andreas Kappel
- Interdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark; (O.R.); (R.E.K.L.); (A.K.); (S.K.)
| | - Søren Kold
- Interdisciplinary Orthopaedics, Aalborg University Hospital, 9000 Aalborg, Denmark; (O.R.); (R.E.K.L.); (A.K.); (S.K.)
| | - John Rasmussen
- Department of Materials and Production, Aalborg University, 9220 Aalborg East, Denmark;
| |
Collapse
|
19
|
Roussos G, Herrero TR, Hill DL, Dowling AV, L T M Müller M, Evers LJW, Burton J, Derungs A, Fisher K, Kilambi KP, Mehrotra N, Bhatnagar R, Sardar S, Stephenson D, Adams JL, Ray Dorsey E, Cosman J. Identifying and characterising sources of variability in digital outcome measures in Parkinson's disease. NPJ Digit Med 2022; 5:93. [PMID: 35840653 PMCID: PMC9284971 DOI: 10.1038/s41746-022-00643-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 06/29/2022] [Indexed: 11/23/2022] Open
Abstract
Smartphones and wearables are widely recognised as the foundation for novel Digital Health Technologies (DHTs) for the clinical assessment of Parkinson's disease. Yet, only limited progress has been made towards their regulatory acceptability as effective drug development tools. A key barrier in achieving this goal relates to the influence of a wide range of sources of variability (SoVs) introduced by measurement processes incorporating DHTs, on their ability to detect relevant changes to PD. This paper introduces a conceptual framework to assist clinical research teams investigating a specific Concept of Interest within a particular Context of Use, to identify, characterise, and when possible, mitigate the influence of SoVs. We illustrate how this conceptual framework can be applied in practice through specific examples, including two data-driven case studies.
Collapse
Affiliation(s)
| | | | | | | | | | - Luc J W Evers
- Radboud University Medical Center and Radboud University, Nijmegen, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Mitternacht J, Hermann A, Carqueville P. Acquisition of Lower-Limb Motion Characteristics with a Single Inertial Measurement Unit—Validation for Use in Physiotherapy. Diagnostics (Basel) 2022; 12:diagnostics12071640. [PMID: 35885542 PMCID: PMC9317307 DOI: 10.3390/diagnostics12071640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 06/21/2022] [Accepted: 07/02/2022] [Indexed: 11/16/2022] Open
Abstract
In physiotherapy, there is still a lack of practical measurement options to track the progress of therapy or rehabilitation following injuries to the lower limbs objectively and reproducibly yet simply and with minimal effort and time. We aim at filling this gap with the design of an IMU (inertial measurement unit) system with only one sensor placed on the tibia edge. In our study, the IMU system evaluated a set of 10 motion tests by a score value for each test and stored them in a database for a more reliable longitudinal assessment of the progress. The sensor analyzed the different motion patterns and obtained characteristic physiological parameters, such as angle ranges, and spatial and angular displacements, such as knee valgus under load. The scores represent the patient’s coordination, stability, strength and speed. To validate the IMU system, these scores were compared to corresponding values from a simultaneously recorded marker-based 3D video motion analysis of the measurements from five healthy volunteers. Score differences between the two systems were almost always within 1–3 degrees for angle measurements. Timing-related measurements were nearly completely identical. The tests on the valgus stability of the knee showed equally small deviations but should nevertheless be repeated with patients, because the healthy subjects showed no signs of instability.
Collapse
|
21
|
An Evaluation of MEMS-IMU Performance on the Absolute Trajectory Error of Visual-Inertial Navigation System. MICROMACHINES 2022; 13:mi13040602. [PMID: 35457906 PMCID: PMC9024873 DOI: 10.3390/mi13040602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/04/2022] [Accepted: 04/09/2022] [Indexed: 02/01/2023]
Abstract
Nowadays, accurate and robust localization is preliminary for achieving a high autonomy for robots and emerging applications. More and more, sensors are fused to guarantee these requirements. A lot of related work has been developed, such as visual-inertial odometry (VIO). In this research, benefiting from the complementary sensing capabilities of IMU and cameras, many problems have been solved. However, few of them pay attention to the impact of different performance IMU on the accuracy of sensor fusion. When faced with actual scenarios, especially in the case of massive hardware deployment, there is the question of how to choose an IMU appropriately? In this paper, we chose six representative IMUs with different performances from consumer-grade to tactical grade for exploring. According to the final performance of VIO based on different IMUs in different scenarios, we analyzed the absolute trajectory error of Visual-Inertial Systems (VINS_Fusion). The assistance of IMU can improve the accuracy of multi-sensor fusion, but the improvement of fusion accuracy with different grade MEMS-IMU is not very significant in the eight experimental scenarios; the consumer-grade IMU can also have an excellent result. In addition, the IMU with low noise is more versatile and stable in various scenarios. The results build the route for the development of Inertial Navigation System (INS) fusion with visual odometry and at the same time, provide a guideline for the selection of IMU.
Collapse
|
22
|
Temporal Synergies Detection in Gait Cyclograms Using Wearable Technology. SENSORS 2022; 22:s22072728. [PMID: 35408342 PMCID: PMC9002595 DOI: 10.3390/s22072728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 03/21/2022] [Accepted: 03/29/2022] [Indexed: 01/02/2023]
Abstract
The human gait can be described as the synergistic activity of all individual components of the sensory–motor system. The central nervous system (CNS) develops synergies to execute endpoint motion by coordinating muscle activity to reflect the global goals of the endpoint trajectory. This paper proposes a new method for assessing temporal dynamic synergies. Principal component analysis (PCA) has been applied on the signals acquired by wearable sensors (inertial measurement units, IMU and ground reaction force sensors, GRF mounted on feet) to detect temporal synergies in the space of two-dimensional PCA cyclograms. The temporal synergy results for different gait speeds in healthy subjects and stroke patients before and after the therapy were compared. The hypothesis of invariant temporal synergies at different gait velocities was statistically confirmed, without the need to record and analyze muscle activity. A significant difference in temporal synergies was noticed in hemiplegic gait compared to healthy gait. Finally, the proposed PCA-based cyclogram method provided the therapy follow-up information about paretic leg gait in stroke patients that was not available by observing conventional parameters, such as temporal and symmetry gait measures.
Collapse
|
23
|
Elble RJ, Ondo W. Tremor rating scales and laboratory tools for assessing tremor. J Neurol Sci 2022; 435:120202. [DOI: 10.1016/j.jns.2022.120202] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 08/08/2021] [Accepted: 02/17/2022] [Indexed: 12/29/2022]
|
24
|
Analysis of Whole-Body Vibration Using Electric Powered Wheelchairs on Surface Transitions. VIBRATION 2022; 5:98-109. [PMID: 35434527 PMCID: PMC9009286 DOI: 10.3390/vibration5010006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Wheelchair users are exposed to whole-body vibration (WBV) when driving on sidewalks and in urban environments; however, there is limited literature on WBV exposure to power wheelchair users when driving during daily activities. Further, surface transitions (i.e., curb-ramps) provide wheelchair accessibility from street intersections to sidewalks; but these require a threshold for water drainage. This threshold may induce high WBV (i.e., root-mean-square and vibration-daily-value accelerations) when accessibility guidelines are not met. This study analyzed the WBV effects on power wheelchairs with passive suspension when driving over surfaces with different thresholds. Additionally, this study introduced a novel power wheelchair with active suspension to reduce WBV levels on surface transitions. Three trials were performed with a commercial power wheelchair with passive suspension, a novel power wheelchair with active suspension, and the novel power wheelchair without active suspension driving on surfaces with five different thresholds. Results show no WBV difference among EPWs across all surfaces. However, the vibration-dose-value increased with higher surface thresholds when using the passive suspension while the active suspension remained constant. Overall, the power wheelchair with active suspension offered similar WBV effects as the passive suspension. While significant vibration-dose-value differences were observed between surface thresholds, all EPWs maintained WBV values below the ISO 2631-1 health caution zone.
Collapse
|
25
|
Subramaniam S, Majumder S, Faisal AI, Deen MJ. Insole-Based Systems for Health Monitoring: Current Solutions and Research Challenges. SENSORS (BASEL, SWITZERLAND) 2022; 22:438. [PMID: 35062398 PMCID: PMC8780030 DOI: 10.3390/s22020438] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 01/01/2022] [Accepted: 01/03/2022] [Indexed: 02/04/2023]
Abstract
Wearable health monitoring devices allow for measuring physiological parameters without restricting individuals' daily activities, providing information that is reflective of an individual's health and well-being. However, these systems need to be accurate, power-efficient, unobtrusive and simple to use to enable a reliable, convenient, automatic and ubiquitous means of long-term health monitoring. One such system can be embedded in an insole to obtain physiological data from the plantar aspect of the foot that can be analyzed to gain insight into an individual's health. This manuscript provides a comprehensive review of insole-based sensor systems that measure a variety of parameters useful for overall health monitoring, with a focus on insole-based PPD measurement systems developed in recent years. Existing solutions are reviewed, and several open issues are presented and discussed. The concept of a fully integrated insole-based health monitoring system and considerations for future work are described. By developing a system that is capable of measuring parameters such as PPD, gait characteristics, foot temperature and heart rate, a holistic understanding of an individual's health and well-being can be obtained without interrupting day-to-day activities. The proposed device can have a multitude of applications, such as for pathology detection, tracking medical conditions and analyzing gait characteristics.
Collapse
Affiliation(s)
- Sophini Subramaniam
- School of Biomedical Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada;
| | - Sumit Majumder
- Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada; (S.M.); (A.I.F.)
- Department of Biomedical Engineering, Chittagong University of Engineering and Technology, Chattogram 4349, Bangladesh
| | - Abu Ilius Faisal
- Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada; (S.M.); (A.I.F.)
| | - M. Jamal Deen
- School of Biomedical Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada;
- Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada; (S.M.); (A.I.F.)
| |
Collapse
|
26
|
SensorHub: Multimodal Sensing in Real-Life Enables Home-Based Studies. SENSORS 2022; 22:s22010408. [PMID: 35009950 PMCID: PMC8749618 DOI: 10.3390/s22010408] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 12/19/2021] [Accepted: 12/22/2021] [Indexed: 01/27/2023]
Abstract
Observational studies are an important tool for determining whether the findings from controlled experiments can be transferred into scenarios that are closer to subjects’ real-life circumstances. A rigorous approach to observational studies involves collecting data from different sensors to comprehensively capture the situation of the subject. However, this leads to technical difficulties especially if the sensors are from different manufacturers, as multiple data collection tools have to run simultaneously. We present SensorHub, a system that can collect data from various wearable devices from different manufacturers, such as inertial measurement units, portable electrocardiographs, portable electroencephalographs, portable photoplethysmographs, and sensors for electrodermal activity. Additionally, our tool offers the possibility to include ecological momentary assessments (EMAs) in studies. Hence, SensorHub enables multimodal sensor data collection under real-world conditions and allows direct user feedback to be collected through questionnaires, enabling studies at home. In a first study with 11 participants, we successfully used SensorHub to record multiple signals with different devices and collected additional information with the help of EMAs. In addition, we evaluated SensorHub’s technical capabilities in several trials with up to 21 participants recording simultaneously using multiple sensors with sampling frequencies as high as 1000 Hz. We could show that although there is a theoretical limitation to the transmissible data rate, in practice this limitation is not an issue and data loss is rare. We conclude that with modern communication protocols and with the increasingly powerful smartphones and wearables, a system like our SensorHub establishes an interoperability framework to adequately combine consumer-grade sensing hardware which enables observational studies in real life.
Collapse
|
27
|
Lapusan C, Hancu O, Rad C. Shape Sensing of Hyper-Redundant Robots Using an AHRS IMU Sensor Network. SENSORS (BASEL, SWITZERLAND) 2022; 22:373. [PMID: 35009919 PMCID: PMC8749592 DOI: 10.3390/s22010373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 12/30/2021] [Accepted: 01/02/2022] [Indexed: 06/14/2023]
Abstract
The paper proposes a novel approach for shape sensing of hyper-redundant robots based on an AHRS IMU sensor network embedded into the structure of the robot. The proposed approach uses the data from the sensor network to directly calculate the kinematic parameters of the robot in modules operational space reducing thus the computational time and facilitating implementation of advanced real-time feedback system for shape sensing. In the paper the method is applied for shape sensing and pose estimation of an articulated joint-based hyper-redundant robot with identical 2-DoF modules serially connected. Using a testing method based on HIL techniques the authors validate the computed kinematic model and the computed shape of the robot prototype. A second testing method is used to validate the end effector pose using an external sensory system. The experimental results obtained demonstrate the feasibility of using this type of sensor network and the effectiveness of the proposed shape sensing approach for hyper-redundant robots.
Collapse
|
28
|
Marques JB, Auliffe SM, Thompson A, Sideris V, Santiago P, Read PJ. The use of wearable technology as an assessment tool to identify between-limb differences during functional tasks following ACL reconstruction. A scoping review. Phys Ther Sport 2022; 55:1-11. [DOI: 10.1016/j.ptsp.2022.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/23/2022] [Accepted: 01/24/2022] [Indexed: 11/25/2022]
|
29
|
Carroll K, Kennedy RA, Koutoulas V, Bui M, Kraan CM. Validation of shoe-worn Gait Up Physilog®5 wearable inertial sensors in adolescents. Gait Posture 2022; 91:19-25. [PMID: 34628218 DOI: 10.1016/j.gaitpost.2021.09.203] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 09/22/2021] [Accepted: 09/30/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Gait Up Physilog® wearable inertial sensors are a powerful alternative to traditional laboratory-based gait assessment for children with gait impairment. To build clinician trust in these devices and ultimately facilitate their use outside confined spaces, studies have examined performance of previous versions of Physilog® wearable inertial sensors but predominant focus has been on older adults. Despite their different gait patterns and behavioural/cognitive profiles, there are limited studies in children. RESEARCH QUESTION To determine whether key spatiotemporal gait parameters (stride length, time and velocity) collected by shoe-worn Physilog®5 sensors in a hallway assessment protocol are a valid method of gait assessment in typically developing adolescents aged 12-15 years. METHODS A total 30 typically developing participants (50 % female) median age 13.7 (interquartile range 2.34) were assessed in an exploratory study whilst walking at self-selected speed over the GAITRite® electronic walkway, concurrently wearing Physilog®5 sensors. Concurrent validity was analysed by Lin's concordance correlation coefficient (CCC), Bland-Altman plots and 95 % limit of agreement. Systematic bias was assessed using 95 % confidence interval of the mean difference. RESULTS Mean stride data demonstrated substantial agreement for stride length (CCC = 0.975) and stride velocity (CCC = 0.979) to almost perfect agreement for stride time (CCC > 0.996). Agreement between the technologies for individual stride-to-stride data remained high for stride time (CCC = 0.952); yet reduced for stride length (CCC = 0.868) and stride velocity (CCC = 0.877). Male/female differences in performance of the technology were observed for stride velocity, favouring females. SIGNIFICANCE Physilog®5 inertial sensors accurately measure walking in adolescents, with stride time the most accurately detected parameter. This demonstrates that wearables can be used by researchers and clinicians working with adolescent groups as an alternative to fixed systems. These findings will ultimately pave the way to using wearables for assessments with children outside of the laboratory environment.
Collapse
Affiliation(s)
- K Carroll
- Department of Neurology, The Royal Children's Hospital, Parkville, Victoria, Australia; Neurosciences, Clinical Sciences, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - R A Kennedy
- Department of Neurology, The Royal Children's Hospital, Parkville, Victoria, Australia; Neurosciences, Clinical Sciences, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - V Koutoulas
- Faculty of Medicine, Dentistry and Health Sciences Department of Paediatrics, University of Melbourne, Parkville, Victoria, Australia
| | - M Bui
- Centre for Epidemiology and Biostatistics, School of Population and Global Health, University of Melbourne, Victoria, Australia
| | - C M Kraan
- Faculty of Medicine, Dentistry and Health Sciences Department of Paediatrics, University of Melbourne, Parkville, Victoria, Australia; Diagnosis and Development, Murdoch Children's Research Institute, Parkville, Victoria, Australia.
| |
Collapse
|
30
|
Betteridge C, Mobbs RJ, Fonseka RD, Natarajan P, Ho D, Choy WJ, Sy LW, Pell N. Objectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis. JOURNAL OF SPINE SURGERY 2021; 7:254-268. [PMID: 34734130 DOI: 10.21037/jss-21-16] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 06/25/2021] [Indexed: 11/06/2022]
Abstract
Background Wearable accelerometer-containing devices have become a mainstay in clinical studies which attempt to classify the gait patterns in various diseases. A gait profile for lumbar spinal stenosis (LSS) has not been developed, and no study has validated a simple wearable system for the clinical assessment of gait in lumbar stenosis. This study identifies the changes to gait patterns that occur in LSS to create a preliminary disease-specific gait profile. In addition, this study compares a chest-based wearable sensor, the MetaMotionC© device and inertial measurement unit python script (MMC/IMUPY) system, against a reference-standard, videography, to preliminarily assess its accuracy in measuring the gait features of patients with LSS. Methods We conduct a cross-sectional observational study examining the walking patterns of 25 LSS patients and 33 healthy controls. To construct a preliminary disease-specific gait profile for LSS, the gait patterns of the 25 LSS patients and 25 healthy controls with similar ages were compared. To assess the accuracy of the MMC/IMUPY system in measuring the gait features of patients with LSS, its results were compared with videography for the 21 LSS and 33 healthy controls whose walking bouts exceeded 30 m. Results Patients suffering from LSS walked significantly slower, with shorter, less frequent steps and higher asymmetry compared to healthy controls. The MMC/IMUPY system had >90% agreement with videography for all spatiotemporal gait metrics that both methods could measure. Conclusions The MMC/IMUPY system is a simple and feasible system for the construction of a preliminary disease-specific gait profile for LSS. Before clinical application in everyday living conditions is possible, further studies involving the construction of a more detailed disease-specific gait profile for LSS by disease severity, and the validation of the MMC/IMUPY system in the home environment, are required.
Collapse
Affiliation(s)
- Callum Betteridge
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - Ralph J Mobbs
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - R Dineth Fonseka
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - Pragadesh Natarajan
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - Daniel Ho
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - Wen Jie Choy
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| | - Luke W Sy
- NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia.,School of Biomechanics, University of New South Wales, Sydney, Australia
| | - Nina Pell
- NeuroSpine Surgery Research Group, Sydney, Australia.,NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia.,Wearables and Gait Assessment Group, Sydney, Australia
| |
Collapse
|
31
|
TRIPOD—A Treadmill Walking Dataset with IMU, Pressure-Distribution and Photoelectric Data for Gait Analysis. DATA 2021. [DOI: 10.3390/data6090095] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Inertial measurement units (IMUs) enable easy to operate and low-cost data recording for gait analysis. When combined with treadmill walking, a large number of steps can be collected in a controlled environment without the need of a dedicated gait analysis laboratory. In order to evaluate existing and novel IMU-based gait analysis algorithms for treadmill walking, a reference dataset that includes IMU data as well as reliable ground truth measurements for multiple participants and walking speeds is needed. This article provides a reference dataset consisting of 15 healthy young adults who walked on a treadmill at three different speeds. Data were acquired using seven IMUs placed on the lower body, two different reference systems (Zebris FDMT-HQ and OptoGait), and two RGB cameras. Additionally, in order to validate an existing IMU-based gait analysis algorithm using the dataset, an adaptable modular data analysis pipeline was built. Our results show agreement between the pressure-sensitive Zebris and the photoelectric OptoGait system (r = 0.99), demonstrating the quality of our reference data. As a use case, the performance of an algorithm originally designed for overground walking was tested on treadmill data using the data pipeline. The accuracy of stride length and stride time estimations was comparable to that reported in other studies with overground data, indicating that the algorithm is equally applicable to treadmill data. The Python source code of the data pipeline is publicly available, and the dataset will be provided by the authors upon request, enabling future evaluations of IMU gait analysis algorithms without the need of recording new data.
Collapse
|
32
|
Bucinskas V, Dzedzickis A, Rozene J, Subaciute-Zemaitiene J, Satkauskas I, Uvarovas V, Bobina R, Morkvenaite-Vilkonciene I. Wearable Feet Pressure Sensor for Human Gait and Falling Diagnosis. SENSORS 2021; 21:s21155240. [PMID: 34372477 PMCID: PMC8347941 DOI: 10.3390/s21155240] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/25/2021] [Accepted: 07/31/2021] [Indexed: 12/20/2022]
Abstract
Human falls pose a serious threat to the person's health, especially for the elderly and disease-impacted people. Early detection of involuntary human gait change can indicate a forthcoming fall. Therefore, human body fall warning can help avoid falls and their caused injuries for the skeleton and joints. A simple and easy-to-use fall detection system based on gait analysis can be very helpful, especially if sensors of this system are implemented inside the shoes without causing a sensible discomfort for the user. We created a methodology for the fall prediction using three specially designed Velostat®-based wearable feet sensors installed in the shoe lining. Measured pressure distribution of the feet allows the analysis of the gait by evaluating the main parameters: stepping rhythm, size of the step, weight distribution between heel and foot, and timing of the gait phases. The proposed method was evaluated by recording normal gait and simulated abnormal gait of subjects. The obtained results show the efficiency of the proposed method: the accuracy of abnormal gait detection reached up to 94%. In this way, it becomes possible to predict the fall in the early stage or avoid gait discoordination and warn the subject or helping companion person.
Collapse
Affiliation(s)
- Vytautas Bucinskas
- Department of Mechatronics, Robotics, and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, LT-03224 Vilnius, Lithuania; (V.B.); (J.R.); (J.S.-Z.)
| | - Andrius Dzedzickis
- Department of Mechatronics, Robotics, and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, LT-03224 Vilnius, Lithuania; (V.B.); (J.R.); (J.S.-Z.)
- Correspondence: (A.D.); (I.M.-V.); Tel.: +370-683-61345 (I.M.-V.)
| | - Juste Rozene
- Department of Mechatronics, Robotics, and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, LT-03224 Vilnius, Lithuania; (V.B.); (J.R.); (J.S.-Z.)
| | - Jurga Subaciute-Zemaitiene
- Department of Mechatronics, Robotics, and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, LT-03224 Vilnius, Lithuania; (V.B.); (J.R.); (J.S.-Z.)
| | - Igoris Satkauskas
- Clinic of Rheumatology, Orthopaedics Traumatology and Reconstructive Surgery, Faculty of Medicine, Vilnius University, LT-03101 Vilnius, Lithuania; (I.S.); (V.U.); (R.B.)
- Centre of Orthopaedics and Traumatology, Republican Vilnius University Hospital, Šiltnamių Str. 29, LT-04130 Vilnius, Lithuania
| | - Valentinas Uvarovas
- Clinic of Rheumatology, Orthopaedics Traumatology and Reconstructive Surgery, Faculty of Medicine, Vilnius University, LT-03101 Vilnius, Lithuania; (I.S.); (V.U.); (R.B.)
- Centre of Orthopaedics and Traumatology, Republican Vilnius University Hospital, Šiltnamių Str. 29, LT-04130 Vilnius, Lithuania
| | - Rokas Bobina
- Clinic of Rheumatology, Orthopaedics Traumatology and Reconstructive Surgery, Faculty of Medicine, Vilnius University, LT-03101 Vilnius, Lithuania; (I.S.); (V.U.); (R.B.)
- Centre of Orthopaedics and Traumatology, Republican Vilnius University Hospital, Šiltnamių Str. 29, LT-04130 Vilnius, Lithuania
| | - Inga Morkvenaite-Vilkonciene
- Department of Mechatronics, Robotics, and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, LT-03224 Vilnius, Lithuania; (V.B.); (J.R.); (J.S.-Z.)
- Correspondence: (A.D.); (I.M.-V.); Tel.: +370-683-61345 (I.M.-V.)
| |
Collapse
|
33
|
A Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Falls. SENSORS 2021; 21:s21134334. [PMID: 34202786 PMCID: PMC8272102 DOI: 10.3390/s21134334] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/19/2021] [Accepted: 06/22/2021] [Indexed: 12/11/2022]
Abstract
The high prevalence of falls and the enormous impact they have on the elderly population is a cause for concern. We aimed to develop a walking-monitor gait pattern (G-STRIDE) for older adults based on a 6-axis inertial measurement (IMU) with the application of pedestrian dead reckoning algorithms and tested its structural and clinical validity. A cross-sectional case–control study was conducted with 21 participants (11 fallers and 10 non-fallers). We measured gait using an IMU attached to the foot while participants walked around different grounds (indoor flooring, outdoor floor, asphalt, etc.). The G-STRIDE consisted of a portable inertial device that monitored the gait pattern and a mobile app for telematic clinical analysis. G-STRIDE made it possible to measure gait parameters under normal living conditions when walking without assessing the patient in the outpatient clinic. Moreover, we verified concurrent validity with convectional outcome measures using intraclass correlation coefficients (ICCs) and analyzed the differences between participants. G-STRIDE showed high estimation accuracy for the walking speed of the elderly and good concurrent validity compared to conventional measures (ICC = 0.69; p < 0.000). In conclusion, the developed inertial-based G-STRIDE can accurately classify older people with risk to fall with a significance as high as using traditional but more subjective clinical methods (gait speed, Timed Up and Go Test).
Collapse
|
34
|
Clemente FM, Akyildiz Z, Pino-Ortega J, Rico-González M. Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review. SENSORS 2021; 21:s21072511. [PMID: 33916801 PMCID: PMC8038306 DOI: 10.3390/s21072511] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 03/29/2021] [Accepted: 04/01/2021] [Indexed: 12/14/2022]
Abstract
The use of inertial measurement unit (IMU) has become popular in sports assessment. In the case of velocity-based training (VBT), there is a need to measure barbell velocity in each repetition. The use of IMUs may make the monitoring process easier; however, its validity and reliability should be established. Thus, this systematic review aimed to (1) identify and summarize studies that have examined the validity of wearable wireless IMUs for measuring barbell velocity and (2) identify and summarize studies that have examined the reliability of IMUs for measuring barbell velocity. A systematic review of Cochrane Library, EBSCO, PubMed, Scielo, Scopus, SPORTDiscus, and Web of Science databases was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. From the 161 studies initially identified, 22 were fully reviewed, and their outcome measures were extracted and analyzed. Among the eight different IMU models, seven can be considered valid and reliable for measuring barbell velocity. The great majority of IMUs used for measuring barbell velocity in linear trajectories are valid and reliable, and thus can be used by coaches for external load monitoring.
Collapse
Affiliation(s)
- Filipe Manuel Clemente
- Instituto Politécnico de Viana do Castelo, Escola Superior Desporto e Lazer, Rua Escola Industrial e Comercial de Nun’Álvares, 4900-347 Viana do Castelo, Portugal
- Instituto de Telecomunicações, Delegação da Covilhã, 1049-001 Lisboa, Portugal
- Correspondence:
| | - Zeki Akyildiz
- Sports Science Department, Gazi University, Teknikokullar, Ankara 06500, Turkey;
| | - José Pino-Ortega
- Faculty of Sports Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
- BIOVETMED & SPORTSCI Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
| | - Markel Rico-González
- BIOVETMED & SPORTSCI Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
- Department of Physical Education and Sport, University of the Basque Country, UPV-EHU, Lasarte 71, 01007 Vitoria-Gasteiz, Spain
| |
Collapse
|
35
|
LOCATE-US: Indoor Positioning for Mobile Devices Using Encoded Ultrasonic Signals, Inertial Sensors and Graph-Matching. SENSORS 2021; 21:s21061950. [PMID: 33802216 PMCID: PMC8001629 DOI: 10.3390/s21061950] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 03/06/2021] [Accepted: 03/08/2021] [Indexed: 12/26/2022]
Abstract
Indoor positioning remains a challenge and, despite much research and development carried out in the last decade, there is still no standard as with the Global Navigation Satellite Systems (GNSS) outdoors. This paper presents an indoor positioning system called LOCATE-US with adjustable granularity for use with commercial mobile devices, such as smartphones or tablets. LOCATE-US is privacy-oriented and allows every device to compute its own position by fusing ultrasonic, inertial sensor measurements and map information. Ultrasonic Local Positioning Systems (U-LPS) based on encoded signals are placed in critical zones that require an accuracy below a few decimeters to correct the accumulated drift errors of the inertial measurements. These systems are well suited to work at room level as walls confine acoustic waves inside. To avoid audible artifacts, the U-LPS emission is set at 41.67 kHz, and an ultrasonic acquisition module with reduced dimensions is attached to the mobile device through the USB port to capture signals. Processing in the mobile device involves an improved Time Differences of Arrival (TDOA) estimation that is fused with the measurements from an external inertial sensor to obtain real-time location and trajectory display at a 10 Hz rate. Graph-matching has also been included, considering available prior knowledge about the navigation scenario. This kind of device is an adequate platform for Location-Based Services (LBS), enabling applications such as augmented reality, guiding applications, or people monitoring and assistance. The system architecture can easily incorporate new sensors in the future, such as UWB, RFiD or others.
Collapse
|
36
|
Zago M, Tarabini M, Delfino Spiga M, Ferrario C, Bertozzi F, Sforza C, Galli M. Machine-Learning Based Determination of Gait Events from Foot-Mounted Inertial Units. SENSORS 2021; 21:s21030839. [PMID: 33513999 PMCID: PMC7866058 DOI: 10.3390/s21030839] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 01/18/2021] [Accepted: 01/22/2021] [Indexed: 12/22/2022]
Abstract
A promising but still scarcely explored strategy for the estimation of gait parameters based on inertial sensors involves the adoption of machine learning techniques. However, existing approaches are reliable only for specific conditions, inertial measurements unit (IMU) placement on the body, protocols, or when combined with additional devices. In this paper, we tested an alternative gait-events estimation approach which is fully data-driven and does not rely on a priori models or assumptions. High-frequency (512 Hz) data from a commercial inertial unit were recorded during 500 steps performed by 40 healthy participants. Sensors’ readings were synchronized with a reference ground reaction force system to determine initial/terminal contacts. Then, we extracted a set of features from windowed data labeled according to the reference. Two gray-box approaches were evaluated: (1) classifiers (decision trees) returning the presence of a gait event in each time window and (2) a classifier discriminating between stance and swing phases. Both outputs were submitted to a deterministic algorithm correcting spurious clusters of predictions. The stance vs. swing approach estimated the stride time duration with an average error lower than 20 ms and confidence bounds between ±50 ms. These figures are suitable to detect clinically meaningful differences across different populations.
Collapse
Affiliation(s)
- Matteo Zago
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy; (M.Z.); (M.D.S.); (M.G.)
| | - Marco Tarabini
- Dipartimento di Meccanica, Politecnico di Milano, 20133 Milano, Italy; (M.T.); (C.F.)
| | - Martina Delfino Spiga
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy; (M.Z.); (M.D.S.); (M.G.)
| | - Cristina Ferrario
- Dipartimento di Meccanica, Politecnico di Milano, 20133 Milano, Italy; (M.T.); (C.F.)
| | - Filippo Bertozzi
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy;
| | - Chiarella Sforza
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy;
- Correspondence: ; Tel.: +39-02-503-15385
| | - Manuela Galli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy; (M.Z.); (M.D.S.); (M.G.)
| |
Collapse
|
37
|
Zago M, Kleiner AFR, Federolf PA. Editorial: Machine Learning Approaches to Human Movement Analysis. Front Bioeng Biotechnol 2021; 8:638793. [PMID: 33553133 PMCID: PMC7862562 DOI: 10.3389/fbioe.2020.638793] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 12/23/2020] [Indexed: 12/16/2022] Open
Affiliation(s)
- Matteo Zago
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | | | | |
Collapse
|
38
|
An Objective Methodology for the Selection of a Device for Continuous Mobility Assessment. SENSORS 2020; 20:s20226509. [PMID: 33202608 PMCID: PMC7696193 DOI: 10.3390/s20226509] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 11/05/2020] [Accepted: 11/10/2020] [Indexed: 01/11/2023]
Abstract
Continuous monitoring by wearable technology is ideal for quantifying mobility outcomes in “real-world” conditions. Concurrent factors such as validity, usability, and acceptability of such technology need to be accounted for when choosing a monitoring device. This study proposes a bespoke methodology focused on defining a decision matrix to allow for effective decision making. A weighting system based on responses (n = 69) from a purpose-built questionnaire circulated within the IMI Mobilise-D consortium and its external collaborators was established, accounting for respondents’ background and level of expertise in using wearables in clinical practice. Four domains (concurrent validity, CV; human factors, HF; wearability and usability, WU; and data capture process, CP), associated evaluation criteria, and scores were established through literature research and group discussions. While the CV was perceived as the most relevant domain (37%), the others were also considered highly relevant (WU: 30%, HF: 17%, CP: 16%). Respondents (~90%) preferred a hidden fixation and identified the lower back as an ideal sensor location for mobility outcomes. Overall, this study provides a novel, holistic, objective, as well as a standardized approach accounting for complementary aspects that should be considered by professionals and researchers when selecting a solution for continuous mobility monitoring.
Collapse
|