De Vita E, Lo Presti D, Massaroni C, Iadicicco A, Schena E, Campopiano S. A review on radiofrequency, laser, and microwave ablations and their thermal monitoring through fiber Bragg gratings. iScience 2023; 26:108260. [PMID: 38026224 PMCID: PMC10660479 DOI: 10.1016/j.isci.2023.108260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023] Open
Abstract
Thermal ablation of tumors aims to apply extreme temperatures inside the target tissue to achieve substantial tumor destruction in a minimally invasive manner. Several techniques are comprised, classified according to the type of energy source. However, the lack of treatment selectivity still needs to be addressed, potentially causing two risks: i) incomplete tumor destruction and recurrence, or conversely, ii) damage of the surrounding healthy tissue. Therefore, the research herein reviewed seeks to develop sensing systems based on fiber Bragg gratings (FBGs) for thermal monitoring inside the lesion during radiofrequency, laser, and microwave ablation. This review shows that, mainly thanks to multiplexing and minimal invasiveness, FBGs provide an optimal sensing solution. Their temperature measurements are the feedback to control the ablation process and allow to investigate different treatments, compare their outcomes, and quantify the impact of factors such as proximity to thermal probe and blood vessels, perfusion, and tissue type.
Collapse
Affiliation(s)
- Elena De Vita
- Department of Engineering, University of Naples “Parthenope”, 80143 Naples, Italy
| | - Daniela Lo Presti
- Department of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy
| | - Carlo Massaroni
- Department of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy
| | - Agostino Iadicicco
- Department of Engineering, University of Naples “Parthenope”, 80143 Naples, Italy
| | - Emiliano Schena
- Department of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy
| | - Stefania Campopiano
- Department of Engineering, University of Naples “Parthenope”, 80143 Naples, Italy
| |
Collapse
|
2
|
Hamidi A, Bayhaqi YA, Canbaz F, Navarini AA, Cattin PC, Zam A. Towards phase-sensitive optical coherence tomography in smart laser osteotomy: temperature feedback. Lasers Med Sci 2023; 38:222. [PMID: 37752387 PMCID: PMC10522524 DOI: 10.1007/s10103-023-03886-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 09/17/2023] [Indexed: 09/28/2023]
Abstract
Thermal effects during bone surgery pose a common challenge, whether using mechanical tools or lasers. An irrigation system is a standard solution to cool the tissue and reduce collateral thermal damage. In bone surgery using Er:YAG laser, insufficient irrigation raises the risk of thermal damage, while excessive water lowers ablation efficiency. This study investigated the potential of optical coherence tomography to provide feedback by relating the temperature rise with the photo-thermal expansion of the tissue. A phase-sensitive optical coherence tomography system (central wavelength of λ=1.288 μm, a bandwidth of 60.9 nm and a sweep rate of 104.17 kHz) was integrated with an Er:YAG laser using a custom-made dichromatic mirror. Phase calibration was performed by monitoring the temperature changes (thermal camera) and corresponding cumulative phase changes using the phase-sensitive optical coherence tomography system during laser ablation. In this experiment, we used an Er:YAG laser with 230 mJ per pulse at 10 Hz for ablation. Calibration coefficients were determined by fitting the temperature values to phase later and used to predict the temperature rise for subsequent laser ablations. Following the phase calibration step, we used the acquired values to predict the temperature rise of three different laser-induced cuts with the same parameters of the ablative laser. The average root-mean-square error for the three experiments was measured to be around 4 °C. In addition to single-point prediction, we evaluated this method's performance to predict the tissue's two-dimensional temperature rise during laser osteotomy. The findings suggest that the proposed principle could be used in the future to provide temperature feedback for minimally invasive laser osteotomy.
Collapse
Affiliation(s)
- Arsham Hamidi
- Biomedical Laser and Optics Group (BLOG), Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland.
| | - Yakub A Bayhaqi
- Biomedical Laser and Optics Group (BLOG), Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland
| | - Ferda Canbaz
- Biomedical Laser and Optics Group (BLOG), Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland
| | - Alexander A Navarini
- Digital Dermatology, Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland
| | - Philippe C Cattin
- Center for Medical Image Analysis and Navigation (CIAN), Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland
| | - Azhar Zam
- Biomedical Laser and Optics Group (BLOG), Department of Biomedical Engineering, University of Basel, CH-4123, Allschwil, Switzerland
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, 129188, UAE
- Tandon School of Engineering, New York University, Brooklyn, NY, 11201, USA
| |
Collapse
|
3
|
Bianchi L, Fiorentini S, Gianella S, Gianotti S, Iadanza C, Asadi S, Saccomandi P. Measurement of Thermal Conductivity and Thermal Diffusivity of Porcine and Bovine Kidney Tissues at Supraphysiological Temperatures up to 93 °C. SENSORS (BASEL, SWITZERLAND) 2023; 23:6865. [PMID: 37571648 PMCID: PMC10422510 DOI: 10.3390/s23156865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 07/14/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023]
Abstract
This experimental study aimed to characterize the thermal properties of ex vivo porcine and bovine kidney tissues in steady-state heat transfer conditions in a wider thermal interval (23.2-92.8 °C) compared to previous investigations limited to 45 °C. Thermal properties, namely thermal conductivity (k) and thermal diffusivity (α), were measured in a temperature-controlled environment using a dual-needle probe connected to a commercial thermal property analyzer, using the transient hot-wire technique. The estimation of measurement uncertainty was performed along with the assessment of regression models describing the trend of measured quantities as a function of temperature to be used in simulations involving heat transfer in kidney tissue. A direct comparison of the thermal properties of the same tissue from two different species, i.e., porcine and bovine kidney tissues, with the same experimental transient hot-wire technique, was conducted to provide indications on the possible inter-species variabilities of k and α at different selected temperatures. Exponential fitting curves were selected to interpolate the measured values for both porcine and bovine kidney tissues, for both k and α. The results show that the k and α values of the tissues remained rather constant from room temperature up to the onset of water evaporation, and a more marked increase was observed afterward. Indeed, at the highest investigated temperatures, i.e., 90.0-92.8 °C, the average k values were subject to 1.2- and 1.3-fold increases, compared to their nominal values at room temperature, in porcine and bovine kidney tissue, respectively. Moreover, at 90.0-92.8 °C, 1.4- and 1.2-fold increases in the average values of α, compared to baseline values, were observed for porcine and bovine kidney tissue, respectively. No statistically significant differences were found between the thermal properties of porcine and bovine kidney tissues at the same selected tissue temperatures despite their anatomical and structural differences. The provided quantitative values and best-fit regression models can be used to enhance the accuracy of the prediction capability of numerical models of thermal therapies. Furthermore, this study may provide insights into the refinement of protocols for the realization of tissue-mimicking phantoms and the choice of tissue models for bioheat transfer studies in experimental laboratories.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (L.B.); (S.F.); (S.G.); (S.G.); (C.I.); (S.A.)
| |
Collapse
|
4
|
Korganbayev S, De Landro M, Bianchi L, Verde J, Saccomandi P. Preliminary Results of Laser Ablation during In Vivo Experiments: Comparison of Thermal Effects Obtained with Bare and Diffuser Tip Applicators. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083042 DOI: 10.1109/embc40787.2023.10340179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
This work is a step towards the analysis of the effect of different laser applicator tips used for laser ablation of liver for in vivo experiments. As the thermal outcome of this minimally invasive treatment for tumors depends upon the interaction between the tissue and the light, the emission pattern of the laser applicator has a key role in the shape and size of the final treated region. Hence, we have compared two different laser applicators: a bare tip fiber (emitting light from the tip and forward) and a diffuser tip fiber (emitting light at 360° circumferentially from the side of the fiber). The experiments have been carried out percutaneously in a preclinical scenario (anesthetized pigs), under computed tomography (CT) guidance. The thermal effects of the two applicators have been assessed in terms of real-time temperature distribution, by means of an array of 40 fiber Bragg grating (FBG) sensors, and in terms of cavitation and ablation volumes, measured through CT post-temperature due to breathing motion has been analyzed and filtered out. Results show that the maximum temperature reached 50.5 °C for the bare tip fiber experiment (measured at 6.24 mm distance from the applicator) and 60.9 °C for the diffuser tip fiber experiment (measured at 5.23 mm distance from the applicator). The diffuser tip fiber allowed to achieve a more symmetrical heat distribution than the bare tip fiber, and without cavitation volume.Clinical Relevance-This work shows the analysis of the thermal effects of different laser fiber tips to improve laser ablation treatment. The results obtained in the preclinical scenario well represent the expected clinical outcome in the treatment of hepatic tumors. Moreover, these findings can be applied to other fields in which laser ablation is the optimal therapeutic choice, such as neurosurgery.
Collapse
|
5
|
Real-time automatic temperature regulation during in vivo MRI-guided laser-induced thermotherapy (MR-LITT). Sci Rep 2023; 13:3279. [PMID: 36841878 PMCID: PMC9968334 DOI: 10.1038/s41598-023-29818-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 02/10/2023] [Indexed: 02/27/2023] Open
Abstract
Precise control of tissue temperature during Laser-Induced Thermotherapy (LITT) procedures has the potential to improve the clinical efficiency and safety of such minimally invasive therapies. We present a method to automatically regulate in vivo the temperature increase during LITT using real-time rapid volumetric Magnetic Resonance thermometry (8 slices acquired every second, with an in-plane resolution of 1.4 mmx1.4 mm and a slice thickness of 3 mm) using the proton-resonance frequency (PRF) shift technique. The laser output power is adjusted every second using a feedback control algorithm (proportional-integral-derivative controller) to force maximal tissue temperature in the targeted region to follow a predefined temperature-time profile. The root-mean-square of the difference between the target temperature and the measured temperature ranged between 0.5 °C and 1.4 °C, for temperature increases between + 5 °C to + 30 °C above body temperature and a long heating duration (up to 15 min), showing excellent accuracy and stability of the method. These results were obtained on a 1.5 T clinical MRI scanner, showing a potential immediate clinical application of such a temperature controller during MR-guided LITT.
Collapse
|
6
|
Temperature Dependence of Thermal Properties of Ex Vivo Porcine Heart and Lung in Hyperthermia and Ablative Temperature Ranges. Ann Biomed Eng 2023; 51:1181-1198. [PMID: 36656452 PMCID: PMC10172290 DOI: 10.1007/s10439-022-03122-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 12/25/2022] [Indexed: 01/20/2023]
Abstract
This work proposes the characterization of the temperature dependence of the thermal properties of heart and lung tissues from room temperature up to > 90 °C. The thermal diffusivity (α), thermal conductivity (k), and volumetric heat capacity (Cv) of ex vivo porcine hearts and deflated lungs were measured with a dual-needle sensor technique. α and k associated with heart tissue remained almost constant until ~ 70 and ~ 80 °C, accordingly. Above ~ 80 °C, a more substantial variation in these thermal properties was registered: at 94 °C, α and k respectively experienced a 2.3- and 1.5- fold increase compared to their nominal values, showing average values of 0.346 mm2/s and 0.828 W/(m·K), accordingly. Conversely, Cv was almost constant until 55 °C and decreased afterward (e.g., Cv = 2.42 MJ/(m3·K) at 94 °C). Concerning the lung tissue, both its α and k were characterized by an exponential increase with temperature, showing a marked increment at supraphysiological and ablative temperatures (at 91 °C, α and k were equal to 2.120 mm2/s and 2.721 W/(m·K), respectively, i.e., 13.7- and 13.1-fold higher compared to their baseline values). Regression analysis was performed to attain the best-fit curves interpolating the measured data, thus providing models of the temperature dependence of the investigated properties. These models can be useful for increasing the accuracy of simulation-based preplanning frameworks of interventional thermal procedures, and the realization of tissue-mimicking materials.
Collapse
|
7
|
Sharma A, Jangam A, Shen JLY, Ahmad A, Arepally N, Rodriguez B, Borrello J, Bouras A, Kleinberg L, Ding K, Hadjipanayis C, Kraitchman DL, Ivkov R, Attaluri A. Validation of a Temperature-Feedback Controlled Automated Magnetic Hyperthermia Therapy Device. Cancers (Basel) 2023; 15:327. [PMID: 36672278 PMCID: PMC9856953 DOI: 10.3390/cancers15020327] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/22/2022] [Accepted: 12/29/2022] [Indexed: 01/05/2023] Open
Abstract
We present in vivo validation of an automated magnetic hyperthermia therapy (MHT) device that uses real-time temperature input measured at the target to control tissue heating. MHT is a thermal therapy that uses heat generated by magnetic materials exposed to an alternating magnetic field. For temperature monitoring, we integrated a commercial fiber optic temperature probe containing four gallium arsenide (GaAs) temperature sensors. The controller device used temperature from the sensors as input to manage power to the magnetic field applicator. We developed a robust, multi-objective, proportional-integral-derivative (PID) algorithm to control the target thermal dose by modulating power delivered to the magnetic field applicator. The magnetic field applicator was a 20 cm diameter Maxwell-type induction coil powered by a 120 kW induction heating power supply operating at 160 kHz. Finite element (FE) simulations were performed to determine values of the PID gain factors prior to verification and validation trials. Ex vivo verification and validation were conducted in gel phantoms and sectioned bovine liver, respectively. In vivo validation of the controller was achieved in a canine research subject following infusion of magnetic nanoparticles (MNPs) into the brain. In all cases, performance matched controller design criteria, while also achieving a thermal dose measured as cumulative equivalent minutes at 43 °C (CEM43) 60 ± 5 min within 30 min.
Collapse
Affiliation(s)
- Anirudh Sharma
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Avesh Jangam
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Harrisburg, PA 17057, USA
| | - Julian Low Yung Shen
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Harrisburg, PA 17057, USA
| | - Aiman Ahmad
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Harrisburg, PA 17057, USA
| | - Nageshwar Arepally
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Harrisburg, PA 17057, USA
| | - Benjamin Rodriguez
- Sinai BioDesign, Mount Sinai Hospital, New York, NY 10029, USA
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Joseph Borrello
- Sinai BioDesign, Mount Sinai Hospital, New York, NY 10029, USA
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Alexandros Bouras
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
- Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
| | - Lawrence Kleinberg
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
| | - Constantinos Hadjipanayis
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
- Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
| | - Dara L. Kraitchman
- Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- Department of Mechanical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Department of Materials Science and Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Anilchandra Attaluri
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Harrisburg, PA 17057, USA
| |
Collapse
|
8
|
Sharma A, Avinash Jangam A, Low Yung Shen J, Ahmad A, Arepally N, Carlton H, Ivkov R, Attaluri A. Design of a temperature-feedback controlled automated magnetic hyperthermia therapy device. FRONTIERS IN THERMAL ENGINEERING 2023; 3:1131262. [PMID: 36945684 PMCID: PMC10026551 DOI: 10.3389/fther.2023.1131262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
Introduction Magnetic hyperthermia therapy (MHT) is a minimally invasive adjuvant therapy capable of damaging tumors using magnetic nanoparticles exposed radiofrequency alternating magnetic fields. One of the challenges of MHT is thermal dose control and excessive heating in superficial tissues from off target eddy current heating. Methods We report the development of a control system to maintain target temperature during MHT with an automatic safety shutoff feature in adherence to FDA Design Control Guidance. A proportional-integral-derivative (PID) control algorithm was designed and implemented in NI LabVIEW®. A standard reference material copper wire was used as the heat source to verify the controller performance in gel phantom experiments. Coupled electromagnetic thermal finite element analysis simulations were used to identify the initial controller gains. Results Results showed that the PID controller successfully achieved the target temperature control despite significant perturbations. Discussion and Conclusion Feasibility of PID control algorithm to improve efficacy and safety of MHT was demonstrated.
Collapse
Affiliation(s)
- Anirudh Sharma
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Avesh Avinash Jangam
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Middletown, PA, United States
| | - Julian Low Yung Shen
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Middletown, PA, United States
| | - Aiman Ahmad
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Middletown, PA, United States
| | - Nageshwar Arepally
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Middletown, PA, United States
| | - Hayden Carlton
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Mechanical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, United States
- Department of Materials Science and Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, United States
- CORRESPONDENCE Robert Ivkov,
| | - Anilchandra Attaluri
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University—Harrisburg, Middletown, PA, United States
| |
Collapse
|
9
|
Chen S, Yan F, Zhong A, Cai L. Effect of Thermal Ablation on Growth Plates: A Study to Explore the Thermal Threshold of Rabbit Growth Plates During Microwave Ablation. Cardiovasc Intervent Radiol 2023; 46:112-119. [PMID: 36053343 DOI: 10.1007/s00270-022-03238-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 07/20/2022] [Indexed: 01/06/2023]
Abstract
PURPOSE To explore the temperature threshold of thermal damage to growth plates. METHODS Nine rabbits were divided into three groups for femoral ablation, exposing the growth plate to different temperatures (T1 = 43-45 °C; T2 = 46-48 °C; T3 = 49-51 °C). After 5 weeks, the changes in the femurs were assessed by macroscopic images, micro-CT, haematoxylin and eosin staining, and immunohistochemistry of Col2a1 (type II collagen). At the cellular level, rabbit epiphyseal chondrocytes were exposed to 37 °C, 44 °C, 47 °C and 50 °C for 5 min. Then, proliferation and chondrogenic differentiation were detected. RESULTS The rabbits in the T2 and T3 groups developed length discrepancies and axial deviations of femurs, abnormal newly formed bone in the marrow cavity, disorganized growth plates and decreased Col2a1 expression. At the cellular level, the cells exposed to 47 °C and 50 °C for 5 min showed decreased viability, increased apoptosis, decreased extracellular matrix synthesis and decreased matrix mineralization. However, the changes in rabbits in the T1 group and cells at 44 °C did not show a significant difference. CONCLUSION The ablation of growth plates at temperatures above 45 °C for 5 min results in decreased chondrocyte viability and disorganized growth plates, leading to growth disturbances. Further studies are warranted to confirm these promising initial results.
Collapse
Affiliation(s)
- Shiliang Chen
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, No.169, Donghu Road, Wuchang District, Wuhan City, Hubei Province, People's Republic of China
| | - Feifei Yan
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, No.169, Donghu Road, Wuchang District, Wuhan City, Hubei Province, People's Republic of China
| | - Ang Zhong
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, No.169, Donghu Road, Wuchang District, Wuhan City, Hubei Province, People's Republic of China
| | - Lin Cai
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, No.169, Donghu Road, Wuchang District, Wuhan City, Hubei Province, People's Republic of China.
| |
Collapse
|
10
|
Sharma A, Cressman E, Attaluri A, Kraitchman DL, Ivkov R. Current Challenges in Image-Guided Magnetic Hyperthermia Therapy for Liver Cancer. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2768. [PMID: 36014633 PMCID: PMC9414548 DOI: 10.3390/nano12162768] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/03/2022] [Accepted: 08/06/2022] [Indexed: 05/09/2023]
Abstract
For patients diagnosed with advanced and unresectable hepatocellular carcinoma (HCC), liver transplantation remains the best option to extend life. Challenges with organ supply often preclude liver transplantation, making palliative non-surgical options the default front-line treatments for many patients. Even with imaging guidance, success following treatment remains inconsistent and below expectations, so new approaches are needed. Imaging-guided thermal therapy interventions have emerged as attractive procedures that offer individualized tumor targeting with the potential for the selective targeting of tumor nodules without impairing liver function. Furthermore, imaging-guided thermal therapy with added standard-of-care chemotherapies targeted to the liver tumor can directly reduce the overall dose and limit toxicities commonly seen with systemic administration. Effectiveness of non-ablative thermal therapy (hyperthermia) depends on the achieved thermal dose, defined as time-at-temperature, and leads to molecular dysfunction, cellular disruption, and eventual tissue destruction with vascular collapse. Hyperthermia therapy requires controlled heat transfer to the target either by in situ generation of the energy or its on-target conversion from an external radiative source. Magnetic hyperthermia (MHT) is a nanotechnology-based thermal therapy that exploits energy dissipation (heat) from the forced magnetic hysteresis of a magnetic colloid. MHT with magnetic nanoparticles (MNPs) and alternating magnetic fields (AMFs) requires the targeted deposition of MNPs into the tumor, followed by exposure of the region to an AMF. Emerging modalities such as magnetic particle imaging (MPI) offer additional prospects to develop fully integrated (theranostic) systems that are capable of providing diagnostic imaging, treatment planning, therapy execution, and post-treatment follow-up on a single platform. In this review, we focus on recent advances in image-guided MHT applications specific to liver cancer.
Collapse
Affiliation(s)
- Anirudh Sharma
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Erik Cressman
- Department of Interventional Radiology, Division of Diagnostic Imaging, MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Anilchandra Attaluri
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, The Pennsylvania State University, Middletown, PA 17057, USA
| | - Dara L. Kraitchman
- Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| |
Collapse
|
11
|
Orrico A, Korganbayev S, Bianchi L, De Landro M, Saccomandi P. Feedback-controlled laser ablation for cancer treatment: comparison of On-Off and PID control strategies . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:5012-5015. [PMID: 36085688 DOI: 10.1109/embc48229.2022.9871972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Laser ablation is a rising technique used to induce a localized temperature increment for tumor ablation. The outcomes of the therapy depend on the tissue thermal history. Monitoring devices help to assess the tissue thermal response, and their combination with a control strategy can be used to promptly address unexpected temperature changes and thus reduce unwanted thermal effects. In this application, numerical simulations can drive the selection of the laser control settings (i.e., laser power and gain parameters) and allow evaluating the thermal effects of the control strategies. In this study, the influence of different control strategies (On-Off and PID-based controls) is quantified considering the treatment time and the thermal effect on the tissue. Finite element model-based simulations were implemented to model the laser-tissue interaction, the heat-transfer, and the consequent thermal damage in liver tissue with tumor. The laser power was modulated based on the temperature feedback provided within the tumor safety margin. Results show that the chosen control strategy does not have a major influence on the extent of thermal damage but on the treatment duration; the percentage of necrosis within the tumor domain is 100% with both strategies, while the treatment duration is 630 s and 786 s for On-Off and PID, respectively. The choice of the control strategy is a trade-off between treatment duration and unwanted temperature overshoot during closed-loop laser ablation. Clinical Relevance-This work establishes that different temperature-based control of the laser ablation procedure does not have a major influence on the extent of thermal damage but on the duration of treatment.
Collapse
|
12
|
Soltani-Sarvestani MA, Cotin S, Saccomandi P. Unscented Kalman Filtering for Real Time Thermometry During Laser Ablation Interventions. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3485-3488. [PMID: 36085919 DOI: 10.1109/embc48229.2022.9871282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
We present a data-assimilation Bayesian framework in the context of laser ablation for the treatment of cancer. For solving the nonlinear estimation of the tissue temperature evolving during the therapy, the Unscented Kalman Filter (UKF) predicts the next thermal status and controls the ablation process, based on sparse temperature information. The purpose of this paper is to study the outcome of the prediction model based on UKF and to assess the influence of different model settings on the framework performances. In particular, we analyze the effects of the time resolution of the filter and the number and the location of the observations. Clinical Relevance - The application of a data-assimilation approach based on limited temperature information allows to monitor and predict in real-time the thermal effects induced by thermal therapy for tumors.
Collapse
|
13
|
Sametova A, Kurmashev S, Ashikbayeva Z, Amantayeva A, Blanc W, Atabaev TS, Tosi D. Fiber-Optic Distributed Sensing Network for Thermal Mapping of Gold Nanoparticles-Mediated Radiofrequency Ablation. BIOSENSORS 2022; 12:352. [PMID: 35624653 PMCID: PMC9138323 DOI: 10.3390/bios12050352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 05/17/2022] [Accepted: 05/17/2022] [Indexed: 11/21/2022]
Abstract
In this work, we report the design of an optical fiber distributed sensing network for the 2-dimensional (2D) in situ thermal mapping of advanced methods for radiofrequency thermal ablation. The sensing system is based on six high-scattering MgO-doped optical fibers, interleaved by a scattering-level spatial multiplexing approach that allows simultaneous detection of each fiber location, in a 40 × 20 mm grid (7.8 mm2 pixel size). Radiofrequency ablation (RFA) was performed on bovine phantom, using a pristine approach and methods mediated by agarose and gold nanoparticles in order to enhance the ablation properties. The 2D sensors allow the detection of spatiotemporal patterns, evaluating the heating properties and investigating the repeatability. We observe that agarose-based ablation yields the widest ablated area in the best-case scenario, while gold nanoparticles-mediated ablation provides the best trade-off between the ablated area (53.0-65.1 mm2, 61.5 mm2 mean value) and repeatability.
Collapse
Affiliation(s)
- Akbota Sametova
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan; (A.S.); (S.K.); (Z.A.); (A.A.)
| | - Sabit Kurmashev
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan; (A.S.); (S.K.); (Z.A.); (A.A.)
| | - Zhannat Ashikbayeva
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan; (A.S.); (S.K.); (Z.A.); (A.A.)
| | - Aida Amantayeva
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan; (A.S.); (S.K.); (Z.A.); (A.A.)
| | - Wilfried Blanc
- Université Côte d’Azur, INPHYNI, CNRS UMR7010, Avenue Joseph Vallot, 06108 Nice, France;
| | - Timur Sh. Atabaev
- Department of Chemistry, Nazarbayev University, 53 Kabanbay Batyr Avenue, Nur-Sultan 010000, Kazakhstan;
| | - Daniele Tosi
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan; (A.S.); (S.K.); (Z.A.); (A.A.)
- National Laboratory Astana, Laboratory of Biosensors and Bioinstruments, Nur-Sultan 010000, Kazakhstan
| |
Collapse
|
14
|
Kim Y, Kim H, Kang HW. Enhancement of gold nanorods-assisted photothermal treatment on cancer with laser power in stepwise modulation. Lasers Surg Med 2022; 54:841-850. [PMID: 35419820 DOI: 10.1002/lsm.23549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 03/18/2022] [Accepted: 03/25/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVES Photothermal therapy (PTT) is a minimally invasive or noninvasive method by destructing cancer cells through selective thermal decomposition. However, a long period of laser irradiation to achieve coagulative necrosis often causes unfavorable thermal damage to the surrounding healthy tissue. The current study aims to evaluate the feasibility of temporal power modulation to improve the treatment efficacy of gold nanorods-assisted PTT against tumor tissue. MATERIALS AND METHODS A total of 25 µg/ml of PEGylated gold nanorods (PEG-GNR) was used as an absorbing agent during 1064 nm laser irradiation for PTT. Temperature monitoring was conducted on the aqueous solution of PEG-GNR for dosimetry comparison. For in vivo tests, CT-26 tumor-bearing murine models with PEG-GNR injected were treated with three irradiation conditions: 3 W/cm2 for 90 s, 1.5 W/cm2 for 180 s, and 3 W/cm2 for 60 s followed by 1.5 W/cm2 for 60 s (modulated). Ten days after the treatments, histology analysis was performed to assess the extent of coagulation necrosis in the treated tissues. RESULTS The temporal power modulation maintained the tissue temperature of around 50°C for a longer period during the irradiation. Histology analysis confirmed that the modulated group entailed a larger coagulative necrosis area with less thermal damage to the peripheral tissue, compared to the other irradiation conditions. CONCLUSION Therefore, the power-modulated PTT could improve treatment efficacy with reduced injury by maintaining the constant tissue temperature. Further studies will examine the feasibility of the proposed technique in large animal models in terms of acute and chronic tissue responses and treatment margin for clinical translations.
Collapse
Affiliation(s)
- Yeongeun Kim
- Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, Korea.,Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan, Korea
| | - Hyejin Kim
- Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan, Korea.,Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan, Korea
| | - Hyun Wook Kang
- Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, Korea.,Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan, Korea.,Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan, Korea
| |
Collapse
|
15
|
Asadi S, Korganbayev S, Xu W, Mapanao AK, Voliani V, Lehto VP, Saccomandi P. Experimental Evaluation of Radiation Response and Thermal Properties of NPs-Loaded Tissues-Mimicking Phantoms. NANOMATERIALS 2022; 12:nano12060945. [PMID: 35335758 PMCID: PMC8950154 DOI: 10.3390/nano12060945] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/06/2022] [Accepted: 03/09/2022] [Indexed: 02/04/2023]
Abstract
Many efforts have recently concentrated on constructing and developing nanoparticles (NPs) as promising thermal agent for optical hyperthermia and photothermal therapy. However, thermal energy transfer in biological tissue is a complex process involving different mechanisms such as conduction, convection, radiation. Therefore, having information about thermal properties of tissue especially when NPs are embedded in is a necessity for predicting the heat transfer during hyperthermia. In this work, the thermal properties of solid phantom based on agar in the presence of three different nanoparticles (BPSi, tNAs, GNRs) and alone were measured and reported as a function of temperature (ranging from 22 to 62 °C). The thermal response of these NPs to an 808 nm laser beam with three different powers were studied in the water comparatively. Agar and tNAs have almost constant thermal properties in the considered range. Among the three NPs, gold has the highest conductivity and diffusivity. At 62 °C BPSi NPs have the similar amount of increase for the diffusivity. The thermal parameters reported in this paper can be useful for the mathematical modeling. Irradiation of the NPs-loaded water phantom displayed the highest radiosensitivity of gold among the three mentioned NPs. However, for the higher power of irradiation, BPSi and tNAs NPs showed the increased absorption of heat during shorter time and the increased temperature gradient slope for the initial 15 s after the irradiation started. The three NPs showed different thermal and irradiation response behavior; however, this comparison study notes the worth of having information about thermal parameters of NPs-loaded tissue for pre-clinical planning.
Collapse
Affiliation(s)
- Somayeh Asadi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (S.K.); (P.S.)
- Correspondence: ; Tel.: +39-022-399-8572
| | - Sanzhar Korganbayev
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (S.K.); (P.S.)
| | - Wujun Xu
- Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland; (W.X.); (V.-P.L.)
| | - Ana Katrina Mapanao
- Center for Nanotechnology Innovation, Istituto Italiano di Tecnologia, 56127 Pisa, Italy; (A.K.M.); (V.V.)
| | - Valerio Voliani
- Center for Nanotechnology Innovation, Istituto Italiano di Tecnologia, 56127 Pisa, Italy; (A.K.M.); (V.V.)
| | - Vesa-Pekka Lehto
- Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland; (W.X.); (V.-P.L.)
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (S.K.); (P.S.)
| |
Collapse
|
16
|
Schulmann N, Soltani-Sarvestani MA, De Landro M, Korganbayev S, Cotin S, Saccomandi P. Model-Based Thermometry for Laser Ablation Procedure Using Kalman Filters and Sparse Temperature Measurements. IEEE Trans Biomed Eng 2022; 69:2839-2849. [PMID: 35230944 DOI: 10.1109/tbme.2022.3155574] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this work, we implement a data-assimilation Bayesian framework for the reconstruction of the spatiotemporal profile of the tissue temperature during laser irradiation. The predictions of a physical model simulating the heat transfer in the tissue are associated with sparse temperature measurements, using an Unscented Kalman Filter. We compare a standard state-estimation filtering procedure with a joint-estimation (state and parameters) approach: whereas in the state-estimation only the temperature is evaluated, in the joint-estimation the filter corrects also uncertain model parameters (i.e., the medium thermal diffusivity, and laser beam properties). We have tested the method on synthetic temperature data, and on the temperature measured on agar-gel phantom and porcine liver with fiber optic sensors. The joint-estimation allows retrieving an accurate estimate of the temperature distribution with a maximal error < 1.5 C in both synthetic and liver 1D data, and < 2 C in phantom 2D data. Our approach allows also suggesting a strategy for optimizing the temperature estimation based on the positions of the sensors. Under the constraint of using only two sensors, optimal temperature estimations are obtained when one sensor is placed in proximity of the source, and the other one is in a non-symmetrical position.
Collapse
|
17
|
Lim S, Truong VG, Kang HW. Impact of residual air trap in balloon on laser treatment of tubular tissue. Lasers Surg Med 2022; 54:767-778. [PMID: 35181900 DOI: 10.1002/lsm.23527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 01/28/2022] [Accepted: 02/06/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVES Tubular tissue, such as the bile duct and esophagus, often suffers from stenosis due to chronic inflammation or excessive contraction of smooth muscle. Laser treatment using a balloon catheter has been used to treat tubular tissue stenosis by mechanically expanding the tissue and irradiating laser light circumferentially on the tissue lumen. As the balloon is inflated with saline, the residual air in a delivery channel is often accumulated in the inflated balloon. Thus, the air trap may cause physical discontinuities at air-saline interface, leading to unpredictable and nonuniform photothermal interactions. The aim of the current study was to evaluate the optical-thermal effects of the air trap in the balloon on laser treatment of the tubular tissue by means of numerical simulations and experimental validations. MATERIALS AND METHODS A balloon-assisted diffusing applicator (BDA) was developed to inflate a balloon and deliver uniform and circumferential laser light. Before the balloon inflation, various numbers of deflations (0, 1, 2, 3, and 4) were applied to estimate the average amount of the air removed from the balloon. Ex vivo experiments using porcine liver duct were conducted with two deflation conditions (D0: no deflation for air trap and D3: three deflations for no air trap). The balloon was horizontally situated during laser irradiation to maintain the air trap at the same position in the balloon by minimizing gravity effect. Upon balloon inflation, 532 nm laser light was delivered through the BDA to the tissue (irradiance = 4 W/cm2 ) at 10 W for 45 seconds to assess the optical-thermal effects of the air trap on the ductal tissue. RESULTS The size of the air trap was noticeably reduced with the number of deflations. The air trap volume in the balloon decreased to 0.5% of the total balloon volume after D3. Ex vivo results demonstrated that thicker coagulative necrosis (CN) for D0 near the air trap region in the tissue than bottom region that contact with saline, representing an asymmetric profile of CN in the tissue. D0 generated 17% thicker and nonuniform CN (overall CN thickness = 1.4 ± 0.7 mm), compared with D3 with no air trap (overall CN thickness = 1.2 ± 0.2 mm; p < 0.05). A threefold larger eccentricity (E) was found in D0 (49 ± 31%) than D3 (15 ± 13%; p < 0.001). CONCLUSION Both numerical simulations and experiments validated the effect of the air trap in a balloon on the distribution of CN in a tubular tissue during BDA-assisted laser treatment. Further in vivo studies will assess the current findings on the air trap for clinical translations of BDA-assisted laser treatment of tubular tissue stenosis.
Collapse
Affiliation(s)
- Seonghee Lim
- Department of Biomedical Engineering, Pukyong National University, Busan, Republic of Korea
| | - Van Gia Truong
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan, Republic of Korea.,Tecure, Inc., Busan, Republic of Korea
| | - Hyun Wook Kang
- Department of Biomedical Engineering, Pukyong National University, Busan, Republic of Korea.,Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan, Republic of Korea.,Tecure, Inc., Busan, Republic of Korea.,Marine-Integrated Biomedical Technology Center, Pukyong National University, Busan, Republic of Korea
| |
Collapse
|
18
|
Bianchi L, Cavarzan F, Ciampitti L, Cremonesi M, Grilli F, Saccomandi P. Thermophysical and mechanical properties of biological tissues as a function of temperature: a systematic literature review. Int J Hyperthermia 2022; 39:297-340. [DOI: 10.1080/02656736.2022.2028908] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Fabiana Cavarzan
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Lucia Ciampitti
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Matteo Cremonesi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Francesca Grilli
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
19
|
Ochoa M, Algorri JF, Roldán-Varona P, Rodríguez-Cobo L, López-Higuera JM. Recent Advances in Biomedical Photonic Sensors: A Focus on Optical-Fibre-Based Sensing. SENSORS (BASEL, SWITZERLAND) 2021; 21:6469. [PMID: 34640788 PMCID: PMC8513032 DOI: 10.3390/s21196469] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 09/21/2021] [Accepted: 09/23/2021] [Indexed: 01/22/2023]
Abstract
In this invited review, we provide an overview of the recent advances in biomedical photonic sensors within the last five years. This review is focused on works using optical-fibre technology, employing diverse optical fibres, sensing techniques, and configurations applied in several medical fields. We identified technical innovations and advancements with increased implementations of optical-fibre sensors, multiparameter sensors, and control systems in real applications. Examples of outstanding optical-fibre sensor performances for physical and biochemical parameters are covered, including diverse sensing strategies and fibre-optical probes for integration into medical instruments such as catheters, needles, or endoscopes.
Collapse
Affiliation(s)
- Mario Ochoa
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - José Francisco Algorri
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - Pablo Roldán-Varona
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| | | | - José Miguel López-Higuera
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| |
Collapse
|
20
|
De Tommasi F, Massaroni C, Grasso RF, Carassiti M, Schena E. Temperature Monitoring in Hyperthermia Treatments of Bone Tumors: State-of-the-Art and Future Challenges. SENSORS (BASEL, SWITZERLAND) 2021; 21:5470. [PMID: 34450911 PMCID: PMC8400360 DOI: 10.3390/s21165470] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 08/05/2021] [Accepted: 08/10/2021] [Indexed: 12/22/2022]
Abstract
Bone metastases and osteoid osteoma (OO) have a high incidence in patients facing primary lesions in many organs. Radiotherapy has long been the standard choice for these patients, performed as stand-alone or in conjunction with surgery. However, the needs of these patients have never been fully met, especially in the ones with low life expectancy, where treatments devoted to pain reduction are pivotal. New techniques as hyperthermia treatments (HTs) are emerging to reduce the associated pain of bone metastases and OO. Temperature monitoring during HTs may significantly improve the clinical outcomes since the amount of thermal injury depends on the tissue temperature and the exposure time. This is particularly relevant in bone tumors due to the adjacent vulnerable structures (e.g., spinal cord and nerve roots). In this Review, we focus on the potential of temperature monitoring on HT of bone cancer. Preclinical and clinical studies have been proposed and are underway to investigate the use of different thermometric techniques in this scenario. We review these studies, the principle of work of the thermometric techniques used in HTs, their strengths, weaknesses, and pitfalls, as well as the strategies and the potential of improving the HTs outcomes.
Collapse
Affiliation(s)
- Francesca De Tommasi
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| | - Rosario Francesco Grasso
- Unit of Interventional Radiology, School of Medicine, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy;
| | - Massimiliano Carassiti
- Unit of Anesthesia, Intensive Care and Pain Management, School of Medicine, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy;
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| |
Collapse
|
21
|
Hernández-Arenas A, Pimentel-Domínguez R, Rodrigo Vélez-Cordero J, Hernández-Cordero J. Fiber optic probe with functional polymer composites for hyperthermia. BIOMEDICAL OPTICS EXPRESS 2021; 12:4730-4744. [PMID: 34513221 PMCID: PMC8407845 DOI: 10.1364/boe.427585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 06/27/2021] [Accepted: 06/28/2021] [Indexed: 06/13/2023]
Abstract
We demonstrate a fiber optic probe incorporating functional polymer composites for controlled generation of photothermal effects. The probe combines carbon-based and rare-earth composites on the tip of standard multimode fibers, thus yielding a compact fiber optic photothermal probe (FOPP) whose temperature can be measured simultaneously through fluorescent thermometry. We evaluate the thermal features of the probe through experiments and numerical calculations showing that large thermal gradients are obtained within the vicinity of the heating zone. The temperatures achieved with the FOPP are within the ranges of interest for hyperthermia and can be attained using low optical powers (< 280 mW).
Collapse
Affiliation(s)
- Alexa Hernández-Arenas
- Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico City 04510, Mexico
| | - Reinher Pimentel-Domínguez
- Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico City 04510, Mexico
| | - J. Rodrigo Vélez-Cordero
- Instituto de Física-Cátedras CONACyT, Universidad Autónoma de San Luis Potosí, San Luis Potosí 78290, San Luis Potosí, Mexico
| | - Juan Hernández-Cordero
- Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico City 04510, Mexico
| |
Collapse
|
22
|
Concept of an In-Plane Displacement Sensor Based on Grating Interferometry with a Stepwise Change of Sensitivity. SENSORS 2021; 21:s21144894. [PMID: 34300633 PMCID: PMC8309853 DOI: 10.3390/s21144894] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 07/14/2021] [Indexed: 12/23/2022]
Abstract
Grating Interferometry, known in the relevant literature as the High Sensitivity Moiré Interferometry, is a method for in-plane displacement and strain measurement. The sensitivity of this method depends on the spatial frequency of the diffraction grating attached to the object under test. For typical specimen grating, with high spatial frequency of 1200 lines per mm, the basic sensitivity is 0.417 µm per fringe. A concept of in-plane displacement sensor based on Grating Interferometry with a stepwise change in sensitivity is presented. It is realized by using the specimen grating with lower spatial frequency. In this case, the grating has more higher diffraction orders and by selecting them appropriately, the sensitivity (chosen from 1.25 μm, 0.625 μm, or 0.417 μm) and the resulting measurement range (chosen from about 600 μm, 300 μm, or 200 μm) can be adjusted to the requirements of a given experiment. A special method of filtration is required in this case. Achromatic configuration with illumination grating was chosen due to its low sensitivity to vibration.
Collapse
|
23
|
Mohammadi A, Bianchi L, Korganbayev S, De Landro M, Saccomandi P. Thermomechanical Modeling of Laser Ablation Therapy of Tumors: Sensitivity Analysis and Optimization of Influential Variables. IEEE Trans Biomed Eng 2021; 69:302-313. [PMID: 34181533 DOI: 10.1109/tbme.2021.3092889] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In cancer treatment, laser ablation is a promising technique used to induce localized thermal damage. Different variables influence the temperature distribution in the tissue and the resulting therapy efficacy; thus, the optimal therapy settings are required for obtaining the desired clinical outcome. In this work, thermomechanical modeling of contactless laser ablation was implemented to analyze the sensitivity of independent variables on the optimal treatment conditions. The Finite Element Method was utilized to solve the governing equations, i.e., the bioheat, mechanical deformation, and the Navier-Stokes equations. Validation of the model was evaluated by comparing experimental and simulated temperatures, which indicated high accuracy for estimating temperature. In particular, the results showed that the model is capable of estimating temperature with a good correlation factor (R=0.98) and low Mean Absolute Error (3.9 C). A sensitivity analysis based on laser irradiation time, power, beam distribution, and the blood vessel depth on temperature distribution and fraction of necrotic tissue was performed. Based on the most significant variables i.e., laser irradiation time and power, an optimization process was performed. This resulted into an indication of the optimal therapy settings for achieving maximum procedure efficiency i.e., the required fraction of necrotic tissue within the target volume, constituted by tumor and safety margins around it.
Collapse
|
24
|
Mohammadi A, Bianchi L, Asadi S, Saccomandi P. Measurement of Ex Vivo Liver, Brain and Pancreas Thermal Properties as Function of Temperature. SENSORS (BASEL, SWITZERLAND) 2021; 21:4236. [PMID: 34205567 PMCID: PMC8235733 DOI: 10.3390/s21124236] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/04/2021] [Accepted: 06/17/2021] [Indexed: 12/11/2022]
Abstract
The ability to predict heat transfer during hyperthermal and ablative techniques for cancer treatment relies on understanding the thermal properties of biological tissue. In this work, the thermal properties of ex vivo liver, pancreas and brain tissues are reported as a function of temperature. The thermal diffusivity, thermal conductivity and volumetric heat capacity of these tissues were measured in the temperature range from 22 to around 97 °C. Concerning the pancreas, a phase change occurred around 45 °C; therefore, its thermal properties were investigated only until this temperature. Results indicate that the thermal properties of the liver and brain have a non-linear relationship with temperature in the investigated range. In these tissues, the thermal properties were almost constant until 60 to 70 °C and then gradually changed until 92 °C. In particular, the thermal conductivity increased by 100% for the brain and 60% for the liver up to 92 °C, while thermal diffusivity increased by 90% and 40%, respectively. However, the heat capacity did not significantly change in this temperature range. The thermal conductivity and thermal diffusivity were dramatically increased from 92 to 97 °C, which seems to be due to water vaporization and state transition in the tissues. Moreover, the measurement uncertainty, determined at each temperature, increased after 92 °C. In the temperature range of 22 to 45 °C, the thermal properties of pancreatic tissue did not change significantly, in accordance with the results for the brain and liver. For the three tissues, the best fit curves are provided with regression analysis based on measured data to predict the tissue thermal behavior. These curves describe the temperature dependency of tissue thermal properties in a temperature range relevant for hyperthermia and ablation treatments and may help in constructing more accurate models of bioheat transfer for optimization and pre-planning of thermal procedures.
Collapse
Affiliation(s)
| | | | | | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (A.M.); (L.B.); (S.A.)
| |
Collapse
|
25
|
Bianchi L, Korganbayev S, Orrico A, De Landro M, Saccomandi P. Quasi-distributed fiber optic sensor-based control system for interstitial laser ablation of tissue: theoretical and experimental investigations. BIOMEDICAL OPTICS EXPRESS 2021; 12:2841-2858. [PMID: 34168905 PMCID: PMC8194627 DOI: 10.1364/boe.419541] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/12/2021] [Accepted: 03/23/2021] [Indexed: 05/08/2023]
Abstract
This work proposes the quasi-distributed real-time monitoring and control of laser ablation (LA) of liver tissue. To confine the thermal damage, a pre-planning stage of the control strategy based on numerical simulations of the bioheat-transfer was developed to design the control parameters, then experimentally assessed. Fiber Bragg grating (FBG) sensors were employed to design the automatic thermometry system used for temperature feedback control for interstitial LA. The tissue temperature was maintained at a pre-set value, and the influence of different sensor locations (on the direction of the beam propagation and backward) on the thermal outcome was evaluated in comparison with the uncontrolled case. Results show that the implemented computational model was able to properly describe the temperature evolution of the irradiated tissue. Furthermore, the realized control strategy allowed for the accurate confinement of the laser-induced temperature increase, especially when the temperature control was actuated by sensors located in the direction of the beam propagation, as confirmed by the calculated fractions of necrotic tissues (e.g., 23 mm3 and 53 mm3 for the controlled and uncontrolled LA, respectively).
Collapse
|
26
|
De Landro M, Espíritu García-Molina I, Barberio M, Felli E, Agnus V, Pizzicannella M, Diana M, Zappa E, Saccomandi P. Hyperspectral Imagery for Assessing Laser-Induced Thermal State Change in Liver. SENSORS 2021; 21:s21020643. [PMID: 33477656 PMCID: PMC7831494 DOI: 10.3390/s21020643] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 01/05/2021] [Accepted: 01/13/2021] [Indexed: 12/16/2022]
Abstract
This work presents the potential of hyperspectral imaging (HSI) to monitor the thermal outcome of laser ablation therapy used for minimally invasive tumor removal. Our main goal is the establishment of indicators of the thermal damage of living tissues, which can be used to assess the effect of the procedure. These indicators rely on the spectral variation of temperature-dependent tissue chromophores, i.e., oxyhemoglobin, deoxyhemoglobin, methemoglobin, and water. Laser treatment was performed at specific temperature thresholds (from 60 to 110 °C) on in-vivo animal liver and was assessed with a hyperspectral camera (500-995 nm) during and after the treatment. The indicators were extracted from the hyperspectral images after the following processing steps: the breathing motion compensation and the spectral and spatial filtering, the selection of spectral bands corresponding to specific tissue chromophores, and the analysis of the areas under the curves for each spectral band. Results show that properly combining spectral information related to deoxyhemoglobin, methemoglobin, lipids, and water allows for the segmenting of different zones of the laser-induced thermal damage. This preliminary investigation provides indicators for describing the thermal state of the liver, which can be employed in the future as clinical endpoints of the procedure outcome.
Collapse
Affiliation(s)
- Martina De Landro
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (M.D.L.); (I.E.G.-M.); (E.Z.)
| | | | - Manuel Barberio
- IHU-Strasbourg, 67000 Strasbourg, France; (M.B.); (E.F.); (V.A.); (M.P.); (M.D.)
- Department of General Surgery, Ospedale Card. G. Panico, 73039 Tricase, Italy
| | - Eric Felli
- IHU-Strasbourg, 67000 Strasbourg, France; (M.B.); (E.F.); (V.A.); (M.P.); (M.D.)
| | - Vincent Agnus
- IHU-Strasbourg, 67000 Strasbourg, France; (M.B.); (E.F.); (V.A.); (M.P.); (M.D.)
| | | | - Michele Diana
- IHU-Strasbourg, 67000 Strasbourg, France; (M.B.); (E.F.); (V.A.); (M.P.); (M.D.)
- Research Institute against Cancer of the Digestive System IRCAD, 67091 Strasbourg, France
- ICube Laboratory, Photonics Instrumentation for Health, 67400 Strasbourg, France
| | - Emanuele Zappa
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (M.D.L.); (I.E.G.-M.); (E.Z.)
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156 Milan, Italy; (M.D.L.); (I.E.G.-M.); (E.Z.)
- Correspondence:
| |
Collapse
|
27
|
Korganbayev S, Orrico A, Bianchi L, Paloschi D, Wolf A, Dostovalov A, Saccomandi P. PID Controlling Approach Based on FBG Array Measurements for Laser Ablation of Pancreatic Tissues. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 2021; 70:1-9. [PMID: 0 DOI: 10.1109/tim.2021.3112790] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|