1
|
Rogers B, Fleitas-Paniagua PR, Murias JM. Improving the Agreement Between the First Heart-Rate-Variability Threshold and the Gas-Exchange Threshold. Int J Sports Physiol Perform 2024:1-10. [PMID: 39348882 DOI: 10.1123/ijspp.2024-0143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 07/15/2024] [Accepted: 07/29/2024] [Indexed: 10/02/2024]
Abstract
PURPOSE The first heart-rate (HR) -variability (HRV) -derived threshold based on detrended fluctuation analysis alpha 1 (DFA a1) has shown inconsistent agreement with the gas-exchange threshold (GET). This study examined whether a custom method of computing the first HRV threshold (HRVT1) based on individual HRV characteristics would improve agreement. METHODS Fourteen participants underwent ramp incremental testing measuring gas-exchange variables and RR intervals. Comparisons were made between the oxygen consumption (V˙O2)/HR at the GET versus the V˙O2/HR at the standard DFA a1 = 0.75 (HRVT1s) or a custom value (HRVT1c) based on the DFA a1 midway between the maximum seen during the early ramp incremental and 0.5. RESULTS Mean values for GET V˙O2 versus HRVT1s V˙O2 and GETHR versus HRVT1sHR were statistically different (25.4 [3.3] vs 29.8 [6.8] mL·kg-1·min-1, P = .01, d = 0.80; 131 [11] vs 146 [22] beats·min-1, P = .005, d = 0.91). There were no statistical differences when using the HRVT1c (25.4 [3.3] vs 25.1 [5.7] mL·kg-1·min-1, P = .77, d = 0.08; 131 [11] vs 132 [17] beats·min-1, P = .65, d = 0.12). Equivalence between GET and HRVT1c V˙O2/HR was also verified. Mean maximal DFA a1 during the early ramp incremental was 1.52 (0.22) with mean HRVT1c of 1.01 (0.11). Pearson r correlation coefficients were between .67 and .70 for all GET to HRVT1 comparisons. The second HRV threshold and respiratory compensation point parameters showed agreement and correlations in line with prior studies. CONCLUSIONS The HRVT1c showed stronger agreement to GET parameters than seen using the HRVT1s. It is recommended that evaluations of the HRVT1 consider this approach in determining the HR and V˙O2 at this threshold.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, FL, USA
| | | | - Juan M Murias
- College of Health and Life Sciences, Hamad Bin Khalifa University, Doha, Qatar
| |
Collapse
|
2
|
Cassirame J, Eustache E, Garbellotto L, Chevrolat S, Gimenez P, Leprêtre PM. Detrended fluctuation analysis to determine physiologic thresholds, investigation and evidence from incremental cycling test. Eur J Appl Physiol 2024:10.1007/s00421-024-05614-z. [PMID: 39340669 DOI: 10.1007/s00421-024-05614-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Accepted: 09/15/2024] [Indexed: 09/30/2024]
Abstract
PURPOSE Training zones are generally assessed by gas-exchange thresholds (GET). Several mathematical analyses of heart rate variability (HRV) are proposed for indirect GET determination. Our study aimed to investigate the accordance of the detrend fluctuation analysis (DFA α1) for determining GET with first (VT1) and second ventilatory (VT2) thresholds in well-trained subjects. METHODS Eighteen female and 38 male sub-elite cyclists performed a maximal incremental cycling test of 2-min stage duration with continuous gas exchange and HR measurements. Power output (PO), Oxygen uptake ( V ˙ O2) and HR at VT1 and VT2 were compared with DFA α1 0.75 (HRVT1) and 0.50 (HRVT2). Agreements between PO, V ˙ O2 and HR values were analyzed using Bland-Altman analysis. RESULTS Large limits of agreement between VT1 and HRVT1 were observed for measures of V ˙ O2 expressed in mL.min-1.kg-1 [- 21.3; + 14.1], HR [ 39.2; + 26.9] bpm and PO [- 118; + 83] watts. Indeed, agreements were also low between VT2 and HRVT2 for measures of V ˙ O2 [- 26.7; + 4.3] mL.min-1.kg-1, HR [- 45.5; + 10.6] bpm and PO [- 157; + 35] watts. Our results also showed a sex effect: women obtained worst predictions based on DFA α1 than men for HR (p = 0.014), PO (p = 0.044) at VT1 andV ˙ O 2 (p = 0.045), HR (p = 0.003) and PO (p = 0.004) at VT2. CONCLUSION There was unsatisfactory agreement between the GET and DFA α1 methods for VT1 and VT2 determination in both sex well-trained cyclists. Trial registration number 2233534 on 2024/03/05 retrospectively registered.
Collapse
Affiliation(s)
- Johan Cassirame
- Laboratory Culture Sport Health and Society (C3S-UR 4660, Sport and Performance Department, University of Franche-Comte, 25000, Besançon, France.
- France EA 7507, Laboratoire Performance, Santé, Métrologie, Société, 51100, Reims, France.
- Mtraining, R&D Division, Ecole Valentin, France.
| | - Esther Eustache
- Institut des Sciences du Sport de l, Université de Lausanne, Laussanne, Switzerland
| | | | | | - Philippe Gimenez
- Laboratory Culture Sport Health and Society (C3S-UR 4660, Sport and Performance Department, University of Franche-Comte, 25000, Besançon, France
| | - Pierre-Marie Leprêtre
- Univ Rouen Normandie, Normandie Univ, CETAPS UR 3882, Rouen, France
- Hospital Centre of Corbie, Unit of Cardiac Rehabilitation, Corbie, France
| |
Collapse
|
3
|
van Rassel CR, Ajayi OO, Sales KM, Clermont CA, Rummel M, MacInnis MJ. Quantifying exercise intensity with fractal correlation properties of heart rate variability: a study on incremental and constant-speed running. Eur J Appl Physiol 2024:10.1007/s00421-024-05592-2. [PMID: 39235602 DOI: 10.1007/s00421-024-05592-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 08/18/2024] [Indexed: 09/06/2024]
Abstract
The short-term scaling exponent of detrended fluctuation analysis (DFAα1) applied to interbeat intervals may provide a method to identify ventilatory thresholds and indicate systemic perturbation during prolonged exercise. The purposes of this study were to (i) identify the gas exchange threshold (GET) and respiratory compensation point (RCP) using DFAα1 values of 0.75 and 0.5 from incremental exercise, (ii) compare DFAα1 thresholds with DFAα1 measures during constant-speed running near the maximal lactate steady state (MLSS), and (iii) assess the repeatability of DFAα1 between MLSS trials. Twelve runners performed an incremental running test and constant-speed running 5% below, at, and 5% above the MLSS, plus a repeat trial at MLSS. During 30-min running trials near MLSS, DFAα1 responses were variable (i.e., 0.27-1.24) and affected by intensity (p = 0.031) and duration (p = 0.003). No difference in DFAα1 was detected between MLSS trials (p = 0.597). In the early phase (~ 8 min), DFAα1 measures at MLSS (0.71 [0.13]) remained higher than the DFAα1 identified at RCP from the incremental test (0.57 [0.13]; p = 0.024). In addition, following ~ 18 min of constant speed running at MLSS, DFAα1 measures (0.64 [0.14]) remained higher than 0.5 (p = 0.011)-the value thought to demarcate the boundaries between heavy and severe exercise intensities. Accordingly, using fixed DFAα1 values associated with the RCP from incremental exercise to guide constant-speed exercise training may produce a greater than expected exercise intensity, however; the dependency of DFAα1 on intensity and duration suggest its potential utility to quantify systemic perturbations imposed by continuous exercise.
Collapse
Affiliation(s)
- C R van Rassel
- Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - O O Ajayi
- Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - K M Sales
- Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - C A Clermont
- Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada
- Canadian Sport Institute Alberta, Calgary, AB, T3B 6B7, Canada
| | - M Rummel
- AI Endurance Inc, Hamilton, ON, L8P 0A1, Canada
| | - M J MacInnis
- Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada.
| |
Collapse
|
4
|
Martín Gómez R, Allevard E, Kamstra H, Cotter J, Lamb P. Validity and Reliability of Movesense HR+ ECG Measurements for High-Intensity Running and Cycling. SENSORS (BASEL, SWITZERLAND) 2024; 24:5713. [PMID: 39275624 PMCID: PMC11397956 DOI: 10.3390/s24175713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 08/29/2024] [Accepted: 08/30/2024] [Indexed: 09/16/2024]
Abstract
Low-cost, portable devices capable of accurate physiological measurements are attractive tools for coaches, athletes, and practitioners. The purpose of this study was primarily to establish the validity and reliability of Movesense HR+ ECG measurements compared to the criterion three-lead ECG, and secondarily, to test the industry leader Garmin HRM. Twenty-one healthy adults participated in running and cycling incremental test protocols to exhaustion, both with rest before and after. Movesense HR+ demonstrated consistent and accurate R-peak detection, with an overall sensitivity of 99.7% and precision of 99.6% compared to the criterion; Garmin HRM sensitivity and precision were 84.7% and 87.7%, respectively. Bland-Altman analysis compared to the criterion indicated mean differences (SD) in RR' intervals of 0.23 (22.3) ms for Movesense HR+ at rest and 0.38 (18.7) ms during the incremental test. The mean difference for Garmin HRM-Pro at rest was -8.5 (111.5) ms and 27.7 (128.7) ms for the incremental test. The incremental test correlation was very strong (r = 0.98) between Movesense HR+ and criterion, and moderate (r = 0.66) for Garmin HRM-Pro. This study developed a robust peak detection algorithm and data collection protocol for Movesense HR+ and established its validity and reliability for ECG measurement.
Collapse
Affiliation(s)
- Raúl Martín Gómez
- School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin 9054, New Zealand
| | - Enzo Allevard
- Auckland Bioengineering Institute, University of Auckland, Auckland 1010, New Zealand
| | - Haye Kamstra
- Department of Human Movement Sciences, Vrije Universiteit Amsterdam, 2025 Amsterdam, The Netherlands
| | - James Cotter
- School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin 9054, New Zealand
| | - Peter Lamb
- School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin 9054, New Zealand
| |
Collapse
|
5
|
Knöbel S, Borchert A, Gatzmaga N, Heilmann F, Musculus L, Laborde S, Lautenbach F. The impact of soccer-specific psychophysiological stress on inhibition and cognitive flexibility in elite youth players. PSYCHOLOGY OF SPORT AND EXERCISE 2024; 74:102682. [PMID: 38821249 DOI: 10.1016/j.psychsport.2024.102682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 04/12/2024] [Accepted: 05/27/2024] [Indexed: 06/02/2024]
Abstract
While researchers and practitioners attribute an essential role to executive functions (EFs) for soccer performance, the usefulness of respective diagnostics and the predictive value remain unclear. One limitation restricting the translation and relevance of study results to improve actual game performance is the insufficient consideration of competitive conditions. Thus, this study aimed to conduct soccer-specific cognitive diagnostics under a soccer-specific psychophysiological stress condition, mimicing the demands of a competitive game. A total of 92 (Mage = 15.17, SDage = 1.45) youth elite players performed tests for inhibition (flanker task) or cognitive flexibility (number-letter task) with a soccer-specific motor response (i.e., pass into goals). After a pre-test in a neutral condition, players were randomly assigned to a neutral (moderate soccer-specific exercise) or a stress condition (physical stress and competitive instructions and filming for psychological stress). Objective (i.e., cortisol, heart rate variability) and subjective stress-related measures (i.e., SAM, VAS) were assessed six times throughout experimental procedure. Analyses revealed significant interaction effects between time and condition for all objective and subjective variables indicating a successful experimental stress induction. For cognitive performance, results revealed significant main effects of time, but no significant interaction effects between time and condition. However, descriptive statistics suggested improved performance under stress, with decreased flanker effect and switch costs. Additionally, response time variability in the flanker task significantly decreased in the stress condition. These findings offer insights into individual stress perception and processing under game-related psychophysiological demands, expanding previous research on situational EF alterations that also hold relevance for applied practitioners.
Collapse
Affiliation(s)
- S Knöbel
- Leipzig University, Faculty of Sport Science, Chair of Sport Psychology, Jahnallee 59, 04109, Leipzig, Germany; Sport Psychology, Institute of Sport Science, Humboldt-Universität zu Berlin, Philippstraße 13, 10115, Berlin, Germany.
| | - A Borchert
- RasenBallsport Leipzig GmbH, Cottaweg 3, 04177, Leipzig, Germany.
| | - N Gatzmaga
- RasenBallsport Leipzig GmbH, Cottaweg 3, 04177, Leipzig, Germany.
| | - F Heilmann
- Movement Science Lab, Institute of Sport Science, Martin-Luther University Halle-Wittenberg, Von-Seckendorff-Platz 2, 06120, Halle, Saale, Germany.
| | - L Musculus
- German Sport University Cologne, Institute of Psychology, Dept. Performance Psychology, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
| | - S Laborde
- German Sport University Cologne, Institute of Psychology, Dept. Performance Psychology, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
| | - F Lautenbach
- Sport Psychology, Institute of Sport Science, Humboldt-Universität zu Berlin, Philippstraße 13, 10115, Berlin, Germany.
| |
Collapse
|
6
|
Fleitas-Paniagua PR, Marinari G, Rasica L, Rogers B, Murias JM. Heart Rate Variability Thresholds: Agreement with Established Approaches and Reproducibility in Trained Females and Males. Med Sci Sports Exerc 2024; 56:1317-1327. [PMID: 38376998 DOI: 10.1249/mss.0000000000003412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
PURPOSE To determine in trained females and males i) the agreement between the gas exchange threshold (GET), lactate threshold 1 (LT1), and heart rate variability threshold 1 (HRVT1), as well as between the respiratory compensation point (RCP), lactate threshold 2 (LT2), and heart rate variability threshold 2 (HRVT2), and ii) the reproducibility of HRVT1 and HRVT2 during 2-min incremental step protocols. METHODS Fifty-seven trained participants (24 females) completed a 2-min step incremental test to task failure. Nineteen participants (eight females) completed a second test to evaluate reproducibility. Gas exchange and ventilatory responses, blood lactate concentration, and RR time series were recorded to assess the oxygen consumption (V̇O 2 ) and heart rate (HR) associated with the GET, RCP, LT1, LT2, HRVT1, and HRVT2. RESULTS V̇O 2 -GET versus V̇O 2 -HRVT1 and HR-GET versus HR-HRVT1 were statistically different for females (29.5 ± 4.0 vs 34.6 ± 6.1 mL·kg -1 ·min -1 ; 154 ± 11 vs 166 ± 12 bpm) and for males (33.9 ± 4.2 vs 42.7 ± 4.6 mL·kg -1 ·min -1 ; 145 ± 11 vs 165 ± 9 bpm; P < 0.001). V̇O 2 and HR at HRVT1 were greater than at LT1 ( P < 0.05). V̇O 2 -RCP versus V̇O 2 -HRVT2 and HR-RCP versus HR-HRVT2 were not statistically different for females (40.1 ± 4.7 vs 39.5 ± 6.7 mL·kg -1 ·min -1 ; 177 ± 9 vs 176 ± 9 bpm) and males (48.4 ± 5.4 vs 47.8 ± 4.8 mL·kg -1 ·min -1 ; 176 ± 8 vs 175 ± 9 bpm; P > 0.05). V̇O 2 and HR responses at LT2 were similar to HRVT2 ( P > 0.05). Intraclass correlation coefficient for V̇O 2 -HRVT1, HR-HRVT1, V̇O 2 -HRVT2, and HR-HRVT2 indicated good reproducibility when comparing the two different time points to standard methods. CONCLUSIONS Whereas HRVT2 is a valid and reproducible estimate of the RCP/LT2, current approaches for HRVT1 estimation did not show good agreement with outcomes at GET and LT1.
Collapse
Affiliation(s)
| | | | - Letizia Rasica
- Faculty of Kinesiology, University of Calgary, Calgary, CANADA
| | - Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, FL
| | | |
Collapse
|
7
|
Sempere-Ruiz N, Sarabia JM, Baladzhaeva S, Moya-Ramón M. Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds. Front Physiol 2024; 15:1329360. [PMID: 38375458 PMCID: PMC10875128 DOI: 10.3389/fphys.2024.1329360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 01/18/2024] [Indexed: 02/21/2024] Open
Abstract
Exercise intensity distribution is crucial for exercise individualization, prescription, and monitoring. As traditional methods to determine intensity thresholds present limitations, heart rate variability (HRV) using DFA a1 has been proposed as a biomarker for exercise intensity distribution. This index has been associated with ventilatory and lactate thresholds in previous literature. This study aims to assess DFA a1's reliability and validity in determining intensity thresholds during an incremental cycling test in untrained healthy adults. Sixteen volunteers (13 males and 3 females) performed two identical incremental cycling stage tests at least 1 week apart. First and second ventilatory thresholds, lactate thresholds, and HRV thresholds (DFA a1 values of 0.75 and 0.5 for HRVT1 and HRVT2, respectively) were determined in heart rate (HR), relative oxygen uptake (VO2rel), and power output (PO) values for both tests. We used intraclass correlation coefficient (ICC), change in mean, and typical error for the reliability analysis, and paired t-tests, correlation coefficients, ICC, and Bland-Altman analysis to assess the agreement between methods. Regarding reliability, HRV thresholds showed the best ICCs when measured in PO (HRVT1: ICC = .87; HRVT2: ICC = .97), comparable to ventilatory and lactate methods. HRVT1 showed the strongest agreement with LA 2.5 in PO (p = 0.09, r = .93, ICC = .93, bias = 9.9 ± 21.1), while HRVT2 reported it with VT2 in PO (p = 0.367, r = .92, ICC = .92, bias = 5.3 ± 21.9). DFA a1 method using 0.75 and 0.5 values is reliable and valid to determine HRV thresholds in this population, especially in PO values.
Collapse
Affiliation(s)
- Noemí Sempere-Ruiz
- Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - José Manuel Sarabia
- Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - Sabina Baladzhaeva
- Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - Manuel Moya-Ramón
- Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain
| |
Collapse
|
8
|
Fleitas-Paniagua PR, de Almeida Azevedo R, Trpcic M, Murias JM, Rogers B. Combining Near-Infrared Spectroscopy and Heart Rate Variability Derived Thresholds to Estimate the Critical Intensity of Exercise. J Strength Cond Res 2024; 38:e16-e24. [PMID: 37815285 DOI: 10.1519/jsc.0000000000004597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/11/2023]
Abstract
ABSTRACT Fleitas-Paniagua, PR, de Almeida Azevedo, R, Trpcic, M, Murias, JM, and Rogers, B. Combining near-infrared spectroscopy and heart rate variability derived thresholds to estimate the critical intensity of exercise. J Strength Cond Res 38(1): e16-e24, 2024-Critical intensity determination often requires costly tools and several testing sessions. Alternative approaches display relatively large individual variation. Therefore, simpler estimations with improved precision are needed. This study evaluated whether averaging the heart rate (HR) and oxygen uptake (V̇O 2 ) responses associated with the muscle deoxyhemoglobin concentration breakpoint ([HHb] BP ) and the heart rate variability (HRV) given by the detrended fluctuation analysis second threshold (HRVT2) during ramp incremental (RI) test improved the accuracy of identifying the HR and V̇O 2 at the respiratory compensation point (RCP). Ten female and 11 male recreationally trained subjects performed a 15 W·minute -1 RI test. Gas exchange, near-infrared spectroscopy (NIRS), and RR interval were recorded to assess the RCP, [HHb] BP , and HRVT2. Heart rate (mean ± SD : 158 ± 14, 156 ± 13, 160 ± 14 and, 158 ± 12 bpm) and V̇O 2 (3.08 ± 0.69, 2.98 ± 0.58, 3.06 ± 0.65, and 3.02 ± 0.60 L·minute -1 ) at the RCP, [HHb] BP , HRVT2, and HRVT2&[HHb] BP average (H&H Av ), respectively, were not significantly different ( p > 0.05). The linear relationship between H&H Av and RCP was higher compared with the relationship between [HHb] BP vs RCP and HRVT2 vs RCP for both HR ( r = 0.85; r = 0.73; r = 0.79, p > 0.05) and V̇O 2 ( r = 0.94; r = 0.93; r = 0.91, p > 0.05). Intraclass correlation between RCP, [HHb] BP , HRVT2, and H&H AV was 0.93 for V̇O 2 and 0.79 for HR. The [HHb] BP and the HRVT2 independently provided V̇O 2 and HR responses that strongly agreed with those at the RCP. Combining [HHb] BP and the HRVT2 resulted in estimations of the V̇O 2 and HR at the RCP that displayed smaller variability compared with each modality alone.
Collapse
Affiliation(s)
| | | | | | - Juan M Murias
- Faculty of Kinesiology, University of Calgary, Calgary, Canada
- College of Health and Life Sciences, Hamad Bin Khalifa University, Doha, Qatar; and
| | - Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, Florida
| |
Collapse
|
9
|
Van Hooren B, Bongers BC, Rogers B, Gronwald T. The Between-Day Reliability of Correlation Properties of Heart Rate Variability During Running. Appl Psychophysiol Biofeedback 2023; 48:453-460. [PMID: 37516677 PMCID: PMC10582140 DOI: 10.1007/s10484-023-09599-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/12/2023] [Indexed: 07/31/2023]
Abstract
The short-term scaling exponent of detrended fluctuation analysis (DFA-a1) of heart rate variability may be a helpful tool to assess autonomic balance as a prelude to daily, individualized training. For this concept to be useful, between-session reliability should be acceptable. The aim of this study was to explore the reliability of DFA-a1 during a low-intensity exercise session in both a non-fatigued and a fatigued condition in healthy males and females. Ten participants completed two sessions with each containing an exhaustive treadmill ramp protocol. Before and after the fatiguing ramp, a standardized submaximal low-intensity exercise bout was performed during which DFA-a1, heart rate, and oxygen consumption (VO2) were measured. We compared between-session reliability of all metrics prior to the ramps (i.e., non-fatigued status) and after the first ramp (i.e., fatigued status). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI), the standard error of measurement, and the smallest worthwhile change (SWC) were determined. The ICC and SWC pre fatiguing ramp were 0.85 (95% CI 0.39-0.96) and 5.5% for DFA-a1, 0.85 (0.38-0.96) and 2.2% for heart rate, and 0.84 (0.31-0.96) and 3.1% for VO2. Post fatiguing ramp, the ICC and SWC were 0.55 (0.00-0.89) and 7.9% for DFA-a1, 0.91 (0.62-0.98) and 1.6% for heart rate, and 0.80 (0.17-0.95) and 3.0% for VO2. DFA-a1 shows generally acceptable to good between-session reliability with a SWC of 0.06 and 0.07 (5.5-7.9%) during non-fatigued and fatigued conditions. This suggests that this metric may be useful to inform on training readiness.
Collapse
Affiliation(s)
- Bas Van Hooren
- Department of Nutrition and Movement Sciences, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| | - Bart C Bongers
- Department of Nutrition and Movement Sciences, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Surgery, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, The Netherlands
| | - Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Hamburg, Germany
| |
Collapse
|
10
|
Van Hooren B, Mennen B, Gronwald T, Bongers BC, Rogers B. Correlation properties of heart rate variability to assess the first ventilatory threshold and fatigue in runners. J Sports Sci 2023:1-10. [PMID: 37916488 DOI: 10.1080/02640414.2023.2277034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 10/22/2023] [Indexed: 11/03/2023]
Abstract
PURPOSE The short-term scaling exponent alpha1 of detrended fluctuation analysis (DFA-a1) of heart rate variability (HRV) has shown potential to delineate the first ventilatory threshold (VT1). The aims of this study were to investigate the accuracy of this method for VT1 determination in runners using a consumer grade chest belt and to explore the effects of acute fatigue. METHODS We compared oxygen uptake (V̇O2) and heart rate (HR) at gas exchange VT1 to V̇O2 and HR at a DFA-a1 value of 0.75. Gas exchange and HRV data were obtained from 14 individuals during a treadmill run involving two incremental ramps. Agreement was assessed using Bland-Altman analysis and linear regression. RESULTS Bland-Altman analysis between gas exchange and HRV V̇O2 and HR at VT1 during the first ramp showed a mean (95% limits of agreement) bias of -0.5 (-6.8 to 5.8) ml∙kg-1∙min-1, and -0.9 (-12.2 to 10.5) beats∙min-1, with R2 of 0.83 and 0.56, respectively. During the second ramp, the differences were -7.3 (-18.1 to 3.5) ml∙kg-1∙min-1 and -12.3 (-30.4 to 5.9) beats∙min-1, with R2 of 0.62 and 0.43, respectively. CONCLUSION A chest-belt derived DFA-a1 of 0.75 is closely related to gas exchange VT1, with the variability in accuracy at an individual level being similar to gas exchange methods. This suggests this to be a useful method for exercise intensity demarcation. The altered relationship during the second ramp indicates that DFA-a1 is only able to accurately demarcate exercise intensity thresholds in a non-fatigued state, but also opens opportunities for fatigue-based training prescription.
Collapse
Affiliation(s)
- Bas Van Hooren
- Department of Nutrition and Movement Sciences, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
| | - Bram Mennen
- Department of Nutrition and Movement Sciences, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
| | - Thomas Gronwald
- MSH Medical School Hamburg, Institute of Interdisciplinary Exercise Science and Sports Medicine, Hamburg, Germany
| | - Bart C Bongers
- Department of Nutrition and Movement Sciences, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
- Department of Surgery, School of Nutrition and Translational Research in Metabolism (NUTRIM), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
| | - Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, Florida, USA
| |
Collapse
|
11
|
Fleitas‐Paniagua PR, de Almeida Azevedo R, Trpcic M, Murias JM, Rogers B. Effect of ramp slope on intensity thresholds based on correlation properties of heart rate variability during cycling. Physiol Rep 2023; 11:e15782. [PMID: 37549966 PMCID: PMC10406567 DOI: 10.14814/phy2.15782] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 07/12/2023] [Accepted: 07/18/2023] [Indexed: 08/09/2023] Open
Abstract
An index of heart rate variability (HRV), detrended fluctuation analysis (DFA a1) has gathered interest as a surrogate marker of exercise intensity boundaries. The aim of this report was to examine heart rate variability threshold (HRVT) behavior across different ramp incremental (RI) slopes. Seventeen participants completed a series of three RI (15, 30, and 45 W · min-1 slopes) with monitoring of gas exchange parameters, heart rate (HR) and HRV. HRVT1 was defined as the V̇O2 or HR at which DFA a1 reached 0.75 and the HRVT2 at which these values reached 0.5. HRVTs were compared by Pearson's r, Bland-Altman analysis, ICC3,1 , ANOVA, and paired t-testing. An excellent degree of reliability was seen across all three ramps, with an ICC3,1 of 0.93 and 0.88 for the HRVT1 V̇O2 and HR, respectively, and 0.90 and 0.92 for the HRVT2 V̇O2 and HR, respectively. Correlations between HRVT1/2 of the individual ramps were high with r values 0.84-0.95 for both HR and V̇O2 . Bland-Altman differences ranged between -1.4 and 1.2 mL · kg-1 · min-1 and -2 and +2 bpm. Paired t-testing showed no mean differences between any HRVT1/2 ramp comparisons. Cycling ramp slope does not appear to affect either HRVT1 or HRVT2 in terms of HR or V̇O2 .
Collapse
Affiliation(s)
| | - Rafael de Almeida Azevedo
- Applied Physiology and Nutrition Research Group ‐ Center of Lifestyle Medicine, Faculdade de Medicina FMUSPUniversidade de São PauloSão PauloBrazil
| | | | - Juan M. Murias
- Faculty of KinesiologyUniversity of CalgaryCalgaryCanada
- College of Health and Life SciencesHamad Bin Khalifa UniversityDohaQatar
| | - Bruce Rogers
- College of MedicineUniversity of Central FloridaOrlandoFloridaUSA
| |
Collapse
|
12
|
Kaufmann S, Gronwald T, Herold F, Hoos O. Heart Rate Variability-Derived Thresholds for Exercise Intensity Prescription in Endurance Sports: A Systematic Review of Interrelations and Agreement with Different Ventilatory and Blood Lactate Thresholds. SPORTS MEDICINE - OPEN 2023; 9:59. [PMID: 37462761 DOI: 10.1186/s40798-023-00607-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 07/03/2023] [Indexed: 07/21/2023]
Abstract
BACKGROUND Exercise intensities are prescribed using specific intensity zones (moderate, heavy, and severe) determined by a 'lower' and a 'higher' threshold. Typically, ventilatory (VT) or blood lactate thresholds (LT), and critical power/speed concepts (CP/CS) are used. Various heart rate variability-derived thresholds (HRVTs) using different HRV indices may constitute applicable alternatives, but a systematic review of the proximity of HRVTs to established threshold concepts is lacking. OBJECTIVE This systematic review aims to provide an overview of studies that determined HRVTs during endurance exercise in healthy adults in comparison with a reference VT and/or LT concept. METHODS A systematic literature search for studies determining HRVTs in healthy individuals during endurance exercise and comparing them with VTs or LTs was conducted in Scopus, PubMed and Web of Science (until January 2022). Studies claiming to describe similar physiological boundaries to delineate moderate from heavy (HRVTlow vs. VTlow and/or LTlow), and heavy from severe intensity zone (HRVThigh vs. VThigh and/or LThigh) were grouped and their results synthesized. RESULTS Twenty-seven included studies (461 participants) showed a mean difference in relative HR between HRVTlow and VTlow of - 0.6%bpm in weighted means and 0.02%bpm between HRVTlow and LTlow. Bias between HR at HRVTlow and VTlow was 1 bpm (limits of agreement (LoA): - 10.9 to 12.8 bpm) and 2.7 bpm (LoA: - 20.4 to 25.8 bpm) between HRVTlow and LTlow. Mean difference in HR between HRVThigh and VThigh was 0.3%bpm in weighted means and 2.9%bpm between HRVThigh and LThigh while bias between HR at HRVThigh and VThigh was - 4 bpm (LoA: - 17.9 to 9.9 bpm) and 2.5 bpm (LoA: - 12.1 to 17.1 bpm) between HRVThigh and LThigh. CONCLUSION HRVTlow seems to be a promising approach for the determination of a 'lower' threshold comparable to VTlow and potentially for HRVThigh compared to VThigh, although the latter needs further empirical evaluation. LoA for both intensity zone boundaries indicates bias of HRVTs on an individual level. Taken together, HRVTs can be a promising alternative for prescribing exercise intensity in healthy, male athletes undertaking endurance activities but due to the heterogeneity of study design, threshold concepts, standardization, and lack of female participants, further research is necessary to draw more robust and nuanced conclusions.
Collapse
Affiliation(s)
- Sebastian Kaufmann
- Center for Sports and Physical Education, Faculty of Human Sciences, Julius-Maximilians-University Wuerzburg, Am Hubland/Sports Center, 97074, Würzburg, Germany.
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Hamburg, Germany
| | - Fabian Herold
- Research Group Degenerative and Chronic Diseases, Movement, Faculty of Health Sciences Brandenburg, University of Potsdam, Potsdam, Germany
| | - Olaf Hoos
- Center for Sports and Physical Education, Faculty of Human Sciences, Julius-Maximilians-University Wuerzburg, Am Hubland/Sports Center, 97074, Würzburg, Germany
| |
Collapse
|
13
|
Lundstrom CJ, Biltz GR, Uithoven KE, Snyder EM. Effects of marathon training on heart rate variability during submaximal running: a comparison of analysis techniques. SPORT SCIENCES FOR HEALTH 2023. [DOI: 10.1007/s11332-023-01062-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
|
14
|
Rogers B, Schaffarczyk M, Gronwald T. Improved Estimation of Exercise Intensity Thresholds by Combining Dual Non-Invasive Biomarker Concepts: Correlation Properties of Heart Rate Variability and Respiratory Frequency. SENSORS (BASEL, SWITZERLAND) 2023; 23:1973. [PMID: 36850571 PMCID: PMC9967516 DOI: 10.3390/s23041973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Identifying exercise intensity boundaries has been shown to be important during endurance training for performance enhancement and rehabilitation. Unfortunately, even though surrogate markers show promise when assessed on a group level, substantial deviation from gold standards can be present in each individual. The aim of this study was to evaluate whether combining two surrogate intensity markers improved this agreement. Electrocardiogram (ECG) and gas exchange data were obtained from 21 participants who performed an incremental cycling ramp to exhaustion and evaluated for first (VT1) and second (VT2) ventilatory thresholds, heart rate (HR) variability (HRV), and ECG derived respiratory frequency (EDR). HRV thresholds (HRVT) were based on the non-linear index a1 of a Detrended Fluctuation Analysis (DFA a1) and EDR thresholds (EDRT) upon the second derivative of the sixth-order polynomial of EDR over time. The average of HRVT and EDRT HR was set as the combined threshold (Combo). Mean VT1 was reached at a HR of 141 ± 15, HRVT1 at 152 ± 14 (p < 0.001), EDRT1 at 133 ± 12 (p < 0.001), and Combo1 at 140 ± 13 (p = 0.36) bpm with Pearson's r of 0.83, 0.78, and 0.84, respectively, for comparisons to VT1. A Bland-Altman analysis showed mean biases of 8.3 ± 7.9, -8.3 ± 9.5, and -1.7 ± 8.3 bpm, respectively. A mean VT2 was reached at a HR of 165 ± 13, HRVT2 at 167 ± 10 (p = 0.89), EDRT2 at 164 ± 14 (p = 0.36), and Combo2 at 164 ± 13 (p = 0.59) bpm with Pearson's r of 0.58, 0.95, and 0.94, respectively, for comparisons to VT2. A Bland-Altman analysis showed mean biases of -0.3 ± 8.9, -1.0 ± 4.6, and -0.6 ± 4.6 bpm, respectively. Both the DFA a1 and EDR intensity thresholds based on HR taken individually had moderate agreement to targets derived through gas exchange measurements. By combining both non-invasive approaches, there was improved correlation, reduced bias, and limits of agreement to the respective corresponding HRs at VT1 and VT2.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, 6850 Lake Nona Boulevard, Orlando, FL 32827-7408, USA
| | - Marcelle Schaffarczyk
- Interdisciplinary Institute of Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| | - Thomas Gronwald
- Interdisciplinary Institute of Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| |
Collapse
|
15
|
Schaffarczyk M, Rogers B, Reer R, Gronwald T. Validation of a non-linear index of heart rate variability to determine aerobic and anaerobic thresholds during incremental cycling exercise in women. Eur J Appl Physiol 2023; 123:299-309. [PMID: 36269394 PMCID: PMC9894976 DOI: 10.1007/s00421-022-05050-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 09/10/2022] [Indexed: 02/06/2023]
Abstract
Studies highlight the usage of non-linear time series analysis of heart rate variability (HRV) using the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFA-alpha1) during exercise to determine aerobic and anaerobic thresholds. The present study aims to further verify this approach in women. Gas exchange and HRV data were collected from 26 female participants with different activity levels. Oxygen uptake (VO2) and heart rate (HR) at first (VT1) and second ventilatory thresholds (VT2) were compared with DFA-alpha1-based thresholds 0.75 (HRVT1) and 0.50 (HRVT2). Results: VO2 at VT1 and VT2 were 25.2 ml/kg/min (± 2.8) and 31.5 ml/kg/min (± 3.6) compared with 26.5 ml/kg/min (± 4.0) and 31.9 ml/kg/min (± 4.5) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.77, 0.84; r = 0.81, 0.86, p < 0.001). The mean HR at VT1 was 147 bpm (± 15.6) and 167 bpm (± 12.7) for VT2, compared with 152 bpm (± 15.5) and 166 bpm (± 13.2) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.87, 0.90; r = 0.87, 0.90, p < 0.001). Bland-Altman analysis for VT1 vs. HRVT1 showed a mean difference of - 1.3 ml/kg/min (± 2.4; LoA: 3.3, - 6.0 ml/kg/min) for VO2 and of - 4.7 bpm (± 7.8; LoA: 10.6, - 20.0 bpm) for HR. VT2 vs. HRVT2 showed a mean difference of - 0.4 ml/kg/min (± 2.3; LoA: 4.1, - 4.9 ml/kg/min) for VO2 and 0.5 bpm (± 5.7; LoA: 11.8, - 10.8 bpm) for HR. DFA-alpha1-based thresholds showed good agreement with traditionally used thresholds and could be used as an alternative approach for marking organismic transition zones for intensity distribution in women.
Collapse
Affiliation(s)
- Marcelle Schaffarczyk
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany.
| | - Bruce Rogers
- Department of Internal Medicine, College of Medicine, University of Central Florida, Boston, USA
| | - Rüdiger Reer
- Department Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, Hamburg, Germany
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany
| |
Collapse
|
16
|
Gąsior JS, Zamunér AR, Madeyska M, Tomik A, Niszczota C, Williams CA, Werner B. Heart Rate Variability in Individuals with Down Syndrome: A Scoping Review with Methodological Considerations. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:941. [PMID: 36673696 PMCID: PMC9859252 DOI: 10.3390/ijerph20020941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/31/2022] [Accepted: 01/01/2023] [Indexed: 06/17/2023]
Abstract
Individuals with Down syndrome (DS) present similar heart rate variability (HRV) parameters at rest but different responses to selected movement maneuvers in comparison to individuals without DS, which indicates reduced vagal regulation. The present study undertakes a scoping review of research on HRV in individuals with DS, with special attention paid to the compliance of the studies with standards and methodological paper guidelines for HRV assessment and interpretation. A review was performed using PubMed, Web of Science and CINAHL databases to search for English language publications from 1996 to 2020 with the MESH terms "heart rate variability" and "down syndrome", with the additional inclusion criteria of including only human participants and empirical investigations. From 74 studies, 15 were included in the review. None of the reviewed studies met the recommendations laid out by the standards and guidelines for providing the acquisition of RR intervals and necessary details on HRV analysis. Since authors publishing papers on this research topic do not adhere to the prescribed standards and guidelines when constructing the methodology, results of the research papers on the topic are not directly comparable. Authors need to design the study methodology more robustly by following the aforementioned standards, guidelines and recommendations.
Collapse
Affiliation(s)
- Jakub S. Gąsior
- Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, 02-091 Warsaw, Poland
| | | | - Margaret Madeyska
- Pediatric Cardiology and General Pediatrics Clinic, Jan Polikarp Brudziński Pediatric Hospital, 02-091 Warsaw, Poland
| | - Anna Tomik
- Faculty of Medicine, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Cezary Niszczota
- Pediatric Cardiology and General Pediatrics Clinic, Jan Polikarp Brudziński Pediatric Hospital, 02-091 Warsaw, Poland
| | - Craig A. Williams
- Children’s Health & Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter EX1 2LU, UK
| | - Bożena Werner
- Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, 02-091 Warsaw, Poland
| |
Collapse
|
17
|
Schaffarczyk M, Rogers B, Reer R, Gronwald T. Fractal correlation properties of HRV as a noninvasive biomarker to assess the physiological status of triathletes during simulated warm-up sessions at low exercise intensity: a pilot study. BMC Sports Sci Med Rehabil 2022; 14:203. [PMID: 36457040 PMCID: PMC9713969 DOI: 10.1186/s13102-022-00596-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 11/23/2022] [Indexed: 12/03/2022]
Abstract
BACKGROUND The non-linear index alpha 1 of Detrended Fluctuation Analysis (DFA a1) of heart rate variability, has been shown to be a marker of fatigue during endurance exercise. This report aims to explore its ability to assess the physiological status as a surrogate metric for "readiness to train" while performing simulated warm-up sessions the day after two different exercise sessions. METHODS 11 triathletes were recruited to determine the first ventilatory threshold (VT1) during a baseline assessment and to perform 10-min of cycling at 90% of VT1 (simulating a warm-up bout) before (PRE) and within 36 h after (POST) light and heavy running exercise. RR intervals were recorded for DFA a1 analysis along with neuromuscular testing to verify the effects of the performed exercise sessions. In addition to common statistical methods, magnitude-based inferences (MBI) were applied to assess the changes in true score and thus also the practical relevance of the magnitude. RESULTS Rating of perceived exertion for the heavy exercise session showed a significant higher rating as opposed to the light exercise session (p < 0.001, d = 0.89). In regard of MBIs, PRE versus POST comparisons revealed a significant reduced DFA a1 with large effect size after the heavy exercise session (p = 0.001, d = - 1.44) and a 99% chance that this negative change was clinically relevant. CONCLUSIONS Despite inter-individual differences, DFA a1 offers potential to assess physiological status and guide athletes in their training as an easy-to-apply monitoring procedure during a standardized warm-up. A regular assessment including individual data history and statistical references for identification of response is recommended. Further data are necessary to confirm the results in a larger and more homogeneous population.
Collapse
Affiliation(s)
- Marcelle Schaffarczyk
- grid.11500.350000 0000 8919 8412Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| | - Bruce Rogers
- grid.170430.10000 0001 2159 2859Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, USA
| | - Rüdiger Reer
- grid.9026.d0000 0001 2287 2617Department Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, Hamburg, Germany
| | - Thomas Gronwald
- grid.11500.350000 0000 8919 8412Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| |
Collapse
|
18
|
Rogers B, Schaffarczyk M, Gronwald T. Estimation of Respiratory Frequency in Women and Men by Kubios HRV Software Using the Polar H10 or Movesense Medical ECG Sensor during an Exercise Ramp. SENSORS (BASEL, SWITZERLAND) 2022; 22:7156. [PMID: 36236256 PMCID: PMC9573071 DOI: 10.3390/s22197156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 09/06/2022] [Accepted: 09/19/2022] [Indexed: 06/16/2023]
Abstract
Monitoring of the physiologic metric, respiratory frequency (RF), has been shown to be of value in health, disease, and exercise science. Both heart rate (HR) and variability (HRV), as represented by variation in RR interval timing, as well as analysis of ECG waveform variability, have shown potential in its measurement. Validation of RF accuracy using newer consumer hardware and software applications have been sparse. The intent of this report is to assess the precision of the RF derived using Kubios HRV Premium software version 3.5 with the Movesense Medical sensor single-channel ECG (MS ECG) and the Polar H10 (H10) HR monitor. Gas exchange data (GE), RR intervals (H10), and continuous ECG (MS ECG) were recorded from 21 participants performing an incremental cycling ramp to failure. Results showed high correlations between the reference GE and both the H10 (r = 0.85, SEE = 4.2) and MS ECG (r = 0.95, SEE = 2.6). Although median values were statistically different via Wilcoxon testing, adjusted median differences were clinically small for the H10 (RF about 1 breaths/min) and trivial for the MS ECG (RF about 0.1 breaths/min). ECG based measurement with the MS ECG showed reduced bias, limits of agreement (maximal bias, -2.0 breaths/min, maximal LoA, 6.1 to -10.0 breaths/min) compared to the H10 (maximal bias, -3.9 breaths/min, maximal LoA, 8.2 to -16.0 breaths/min). In conclusion, RF derived from the combination of the MS ECG sensor with Kubios HRV Premium software, tracked closely to the reference device through an exercise ramp, illustrates the potential for this system to be of practical usage during endurance exercise.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, 6850 Lake Nona Boulevard, Orlando, FL 32827-7408, USA
| | - Marcelle Schaffarczyk
- Interdisciplinary Institute of Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| | - Thomas Gronwald
- Interdisciplinary Institute of Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany
| |
Collapse
|
19
|
Schaffarczyk M, Rogers B, Reer R, Gronwald T. Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22176536. [PMID: 36081005 PMCID: PMC9459793 DOI: 10.3390/s22176536] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/23/2022] [Accepted: 08/25/2022] [Indexed: 05/09/2023]
Abstract
Heart rate variability (HRV) is frequently applied in sport-specific settings. The rising use of freely accessible applications for its recording requires validation processes to ensure accurate data. It is the aim of this study to compare the HRV data obtained by the Polar H10 sensor chest strap device and an electrocardiogram (ECG) with the focus on RR intervals and short-term scaling exponent alpha 1 of Detrended Fluctuation Analysis (DFA a1) as non-linear metric of HRV analysis. A group of 25 participants performed an exhaustive cycling ramp with measurements of HRV with both recording systems. Average time between heartbeats (RR), heart rate (HR) and DFA a1 were recorded before (PRE), during, and after (POST) the exercise test. High correlations were found for the resting conditions (PRE: r = 0.95, rc = 0.95, ICC3,1 = 0.95, POST: r = 0.86, rc = 0.84, ICC3,1 = 0.85) and for the incremental exercise (r > 0.93, rc > 0.93, ICC3,1 > 0.93). While PRE and POST comparisons revealed no differences, significant bias could be found during the exercise test for all variables (p < 0.001). For RR and HR, bias and limits of agreement (LoA) in the Bland−Altman analysis were minimal (RR: bias of 0.7 to 0.4 ms with LoA of 4.3 to −2.8 ms during low intensity and 1.3 to −0.5 ms during high intensity, HR: bias of −0.1 to −0.2 ms with LoA of 0.3 to −0.5 ms during low intensity and 0.4 to −0.7 ms during high intensity). DFA a1 showed wider bias and LoAs (bias of 0.9 to 8.6% with LoA of 11.6 to −9.9% during low intensity and 58.1 to −40.9% during high intensity). Linear HRV measurements derived from the Polar H10 chest strap device show strong agreement and small bias compared with ECG recordings and can be recommended for practitioners. However, with respect to DFA a1, values in the uncorrelated range and during higher exercise intensities tend to elicit higher bias and wider LoA.
Collapse
Affiliation(s)
- Marcelle Schaffarczyk
- Department Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, 20148 Hamburg, Germany
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, 20457 Hamburg, Germany
- Correspondence:
| | - Bruce Rogers
- Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Rüdiger Reer
- Department Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, 20148 Hamburg, Germany
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, 20457 Hamburg, Germany
| |
Collapse
|
20
|
Rogers B, Gronwald T. Fractal Correlation Properties of Heart Rate Variability as a Biomarker for Intensity Distribution and Training Prescription in Endurance Exercise: An Update. Front Physiol 2022; 13:879071. [PMID: 35615679 PMCID: PMC9124938 DOI: 10.3389/fphys.2022.879071] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 04/13/2022] [Indexed: 12/30/2022] Open
Abstract
While established methods for determining physiologic exercise thresholds and intensity distribution such as gas exchange or lactate testing are appropriate for the laboratory setting, they are not easily obtainable for most participants. Data over the past two years has indicated that the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFA a1), a heart rate variability (HRV) index representing the degree of fractal correlation properties of the cardiac beat sequence, shows promise as an alternative for exercise load assessment. Unlike conventional HRV indexes, it possesses a dynamic range throughout all intensity zones and does not require prior calibration with an incremental exercise test. A DFA a1 value of 0.75, reflecting values midway between well correlated fractal patterns and uncorrelated behavior, has been shown to be associated with the aerobic threshold in elite, recreational and cardiac disease populations and termed the heart rate variability threshold (HRVT). Further loss of fractal correlation properties indicative of random beat patterns, signifying an autonomic state of unsustainability (DFA a1 of 0.5), may be associated with that of the anaerobic threshold. There is minimal bias in DFA a1 induced by common artifact correction methods at levels below 3% and negligible change in HRVT even at levels of 6%. DFA a1 has also shown value for exercise load management in situations where standard intensity targets can be skewed such as eccentric cycling. Currently, several web sites and smartphone apps have been developed to track DFA a1 in retrospect or in real-time, making field assessment of physiologic exercise thresholds and internal load assessment practical. Although of value when viewed in isolation, DFA a1 tracking in combination with non-autonomic markers such as power/pace, open intriguing possibilities regarding athlete durability, identification of endurance exercise fatigue and optimization of daily training guidance.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, FL, United States
- *Correspondence: Bruce Rogers,
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Hamburg, Germany
| |
Collapse
|
21
|
Rogers B, Berk S, Gronwald T. An Index of Non-Linear HRV as a Proxy of the Aerobic Threshold Based on Blood Lactate Concentration in Elite Triathletes. Sports (Basel) 2022; 10:sports10020025. [PMID: 35202064 PMCID: PMC8875480 DOI: 10.3390/sports10020025] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 01/28/2022] [Accepted: 02/17/2022] [Indexed: 01/23/2023] Open
Abstract
A non-linear index of heart rate (HR) variability (HRV) known as alpha1 of Detrended Fluctuation Analysis (DFA a1) has been shown to change with increasing exercise intensity, crossing a value of 0.75 at the aerobic threshold (AT) in recreational runners defining a HRV threshold (HRVT). Since large volumes of low-intensity training below the AT is recommended for many elite endurance athletes, confirmation of this relationship in this specific group would be advantageous for the purposes of training intensity distribution monitoring. Nine elite triathletes (7 male, 2 female) attended a training camp for diagnostic purposes. Lactate testing was performed with an incremental cycling ramp test to exhaustion for the determination of the first lactate threshold based on the log–log calculation method (LT1). Concurrent measurements of cardiac beta-to-beat intervals were performed to determine the HRVT. Mean LT1 HR of all 9 participants was 155.8 bpm (±7.0) vs. HRVT HR of 153.7 bpm (±10.1) (p = 0.52). Mean LT1 cycling power was 252.3 W (±48.1) vs. HRVT power of 247.0 W (±53.6) (p = 0.17). Bland–Altman analysis showed mean differences of −1.7 bpm and −5.3 W with limits of agreement (LOA) 13.3 to −16.7 bpm and 15.1 to −25.6 W for HR and cycling power, respectively. The DFA a1-based HRVT closely agreed with the LT1 in a group of elite triathletes. Since large volumes of low-intensity exercise are recommended for successful endurance performance, the fractal correlation properties of HRV show promise as a low-cost, non-invasive option to that of lactate testing for identification of AT-related training boundaries.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, 6850 Lake Nona Boulevard, Orlando, FL 32827-7408, USA
- Correspondence:
| | - Sander Berk
- Dutch Triathlon Federation, Papendallaan 49, 6816 VD Arnhem, The Netherlands;
| | - Thomas Gronwald
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany;
| |
Collapse
|
22
|
Prigent G, Apte S, Paraschiv-Ionescu A, Besson C, Gremeaux V, Aminian K. Concurrent Evolution of Biomechanical and Physiological Parameters With Running-Induced Acute Fatigue. Front Physiol 2022; 13:814172. [PMID: 35222081 PMCID: PMC8874325 DOI: 10.3389/fphys.2022.814172] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/10/2022] [Indexed: 12/28/2022] Open
Abstract
Understanding the influence of running-induced acute fatigue on the homeostasis of the body is essential to mitigate the adverse effects and optimize positive adaptations to training. Fatigue is a multifactorial phenomenon, which influences biomechanical, physiological, and psychological facets. This work aimed to assess the evolution of these three facets with acute fatigue during a half-marathon. 13 recreational runners were equipped with one inertial measurement unit (IMU) on each foot, one combined global navigation satellite system-IMU-electrocardiogram sensor on the chest, and an Android smartphone equipped with an audio recording application. Spatio-temporal parameters for the running gait, along with the heart rate, its variability and complexity were computed using validated algorithms. Perceived fatigability was assessed using the rating-of-fatigue (ROF) scale at every 10 min of the race. The data was split into eight equal segments, corresponding to at least one ROF value per segment, and only level running parts were retained for analysis. During the race, contact time, duty factor, and trunk anteroposterior acceleration increased, and the foot strike angle and vertical stiffness decreased significantly. Heart rate showed a progressive increase, while the metrics for heart rate variability and complexity decreased during the race. The biomechanical parameters showed a significant alteration even with a small change in perceived fatigue, whereas the heart rate dynamics altered at higher changes. When divided into two groups, the slower runners presented a higher change in heart rate dynamics throughout the race than the faster runners; they both showed similar trends for the gait parameters. When tested for linear and non-linear correlations, heart rate had the highest association with biomechanical parameters, while the trunk anteroposterior acceleration had the lowest association with heart rate dynamics. These results indicate the ability of faster runners to better judge their physiological limits and hint toward a higher sensitivity of perceived fatigue to neuromuscular changes in the running gait. This study highlights measurable influences of acute fatigue, which can be studied only through concurrent measurement of biomechanical, physiological, and psychological facets of running in real-world conditions.
Collapse
Affiliation(s)
- Gäelle Prigent
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Salil Apte
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Anisoara Paraschiv-Ionescu
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Cyril Besson
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Vincent Gremeaux
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|
23
|
Rogers B, Gronwald T, Mourot L. Analysis of Fractal Correlation Properties of Heart Rate Variability during an Initial Session of Eccentric Cycling. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:10426. [PMID: 34639723 PMCID: PMC8508542 DOI: 10.3390/ijerph181910426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/27/2021] [Accepted: 10/01/2021] [Indexed: 12/30/2022]
Abstract
Eccentric cycling (ECC) has attracted attention as a method to improve muscle strength and aerobic fitness in populations unable to tolerate conventional methods. However, agreement on exercise prescription targets have been problematic. The current report is an initial exploration of a potentially useful tool, a nonlinear heart rate (HR) variability (HRV) index based on the short-term scaling exponent alpha1 of detrended fluctuation analysis (DFA a1), which has been previously shown to correspond to exercise intensity. Eleven male volunteers performed 45 min of concentric (CON) cycling and ECC separated by 1 month. Work rates were matched for HR (~50% of the maximal HR) during the first 5 min and remained stable thereafter. HRV, HR, oxygen consumption (VO2), and cycling power were monitored and evaluated at elapsed times of 10 (T10) and 45 (T45) minutes duration. HR significantly increased between ECC T10 and ECC T45 (p = 0.003, d = 1.485), while DFA a1 significantly decreased (p = 0.004, d = 1.087). During CON, HR significantly increased (p < 0.001 d = 1.570) without significant DFA a1 change (p = 0.48, d = 0.22). Significantly higher HR was observed at T45 in ECC than in CON (p = 0.047, d = 1.059). A session of unaccustomed ECC lead to decreased values of DFA a1 at T45 in comparison to that seen with CON at similar VO2. ECC lead to altered autonomic nervous system balance as reflected by the loss of correlation properties compared to CON.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, 6850 Lake Nona Boulevard, Orlando, FL 32827-7408, USA
| | - Thomas Gronwald
- Faculty of Health Sciences, Department of Performance, Neuroscience, Therapy and Health, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany;
| | - Laurent Mourot
- EA3920 Prognostic Factors and Regulatory Factors of Cardiac and Vascular Pathologies, Exercise Performance Health Innovation (EPHI) Platform, University of Bourgogne Franche-Comté, 25000 Besançon, France;
- Division for Physical Education, Tomsk Polytechnic University, 634040 Tomsk, Russia
| |
Collapse
|
24
|
Aerobic Threshold Identification in a Cardiac Disease Population Based on Correlation Properties of Heart Rate Variability. J Clin Med 2021; 10:jcm10184075. [PMID: 34575188 PMCID: PMC8465546 DOI: 10.3390/jcm10184075] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/03/2021] [Accepted: 09/06/2021] [Indexed: 01/22/2023] Open
Abstract
An index of heart rate (HR) variability correlation properties, the short-term scaling exponent alpha1 of detrended fluctuation analysis (DFA a1) has shown potential to delineate the first ventilatory threshold (VT1). This study aims to extend this concept to a group of participants with cardiac disease. Sixteen volunteers with stable coronary disease or heart failure performed an incremental cycling ramp to exhaustion PRE and POST a 3-week training intervention. Oxygen uptake (VO2) and HR at VT1 were obtained from a metabolic cart. An ECG was processed for DFA a1 and HR. The HR variability threshold (HRVT) was defined as the VO2, HR or power where DFA a1 reached a value of 0.75. Mean VT1 was reached at 16.82 ± 5.72 mL/kg/min, HR of 91.3 ± 11.9 bpm and power of 67.8 ± 17.9 watts compared to HRVT at 18.02 ± 7.74 mL/kg/min, HR of 94.7 ± 14.2 bpm and power of 73.2 ± 25.0 watts. Linear relationships were seen between modalities, with Pearson’s r of 0.95 (VO2), 0.86 (HR) and 0.87 (power). Bland–Altman assessment showed mean differences of 1.20 mL/kg/min, 3.4 bpm and 5.4 watts. Mean peak VO2 and VT1 did not change after training intervention. However, the correlation between PRE to POST change in VO2 at VT1 with the change in VO2 at HRVT was significant (r = 0.84, p < 0.001). Reaching a DFA a1 of 0.75 was associated with the VT1 in a population with cardiac disease. VT1 change after training intervention followed that of the HRVT, confirming the relationship between these parameters.
Collapse
|
25
|
Rogers B, Mourot L, Doucende G, Gronwald T. Fractal correlation properties of heart rate variability as a biomarker of endurance exercise fatigue in ultramarathon runners. Physiol Rep 2021; 9:e14956. [PMID: 34291602 PMCID: PMC8295593 DOI: 10.14814/phy2.14956] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 06/11/2021] [Accepted: 06/17/2021] [Indexed: 12/28/2022] Open
Abstract
Although heart rate variability (HRV) indexes have been helpful for monitoring the fatigued state while resting, little data indicate that there is comparable potential during exercise. Since an index of HRV based on fractal correlation properties, alpha 1 of detrended fluctuation analysis (DFA a1) displays overall organismic demands, alteration during exertion may provide insight into physiologic changes accompanying fatigue. Two weeks after collecting baseline demographic and gas exchange data, 11 experienced ultramarathon runners were divided into two groups. Seven runners performed a simulated ultramarathon for 6 h (Fatigue group, FG) and four runners performed daily activity over a similar period (Control group, CG). Before (Pre) and after (Post) the ultramarathon or daily activity, DFA a1, heart rate (HR), running economy (RE) and countermovement jumps (CMJ) were measured while running on a treadmill at 3 m/s. In Pre versus Post comparisons, data showed a decline with large effect size in DFA a1 post intervention only for FG (Pre: 0.71, Post: 0.32; d = 1.34), with minor differences and small effect sizes in HR (d = 0.02) and RE (d = 0.21). CG showed only minor differences with small effect sizes in DFA a1 (d = 0.19), HR (d = 0.15), and RE (d = 0.31). CMJ vertical peak force showed fatigue-induced decreases with large effect size in FG (d = 0.82) compared to CG (d = 0.02). At the completion of an ultramarathon, DFA a1 decreased with large effect size while running at low intensity compared to pre-race values. DFA a1 may offer an opportunity for real-time tracking of physiologic status in terms of monitoring for fatigue and possibly as an early warning signal of systemic perturbation.
Collapse
Affiliation(s)
- Bruce Rogers
- College of MedicineUniversity of Central FloridaOrlandoFLUSA
| | - Laurent Mourot
- EA3920 Prognostic Factors and Regulatory Factors of Cardiac and Vascular PathologiesExercise Performance Health Innovation (EPHI) platform, University of Bourgogne Franche‐ComtéBesançonFrance
- National Research Tomsk Polytechnic UniversityTomsk OblastRussia
| | - Gregory Doucende
- Université de Perpignan Via DomitiaLaboratoire Européen Performance Santé Altitude (LEPSA)BesançonFrance
| | - Thomas Gronwald
- Faculty of Health SciencesDepartment of Performance, NeuroscienceTherapy and HealthMSH Medical School HamburgUniversity of Applied Sciences and Medical UniversityHamburgGermany
| |
Collapse
|
26
|
Gronwald T, Berk S, Altini M, Mourot L, Hoos O, Rogers B. Real-Time Estimation of Aerobic Threshold and Exercise Intensity Distribution Using Fractal Correlation Properties of Heart Rate Variability: A Single-Case Field Application in a Former Olympic Triathlete. Front Sports Act Living 2021; 3:668812. [PMID: 34124661 PMCID: PMC8193503 DOI: 10.3389/fspor.2021.668812] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 05/04/2021] [Indexed: 12/13/2022] Open
Abstract
A non-linear heart rate variability (HRV) index based on fractal correlation properties called alpha1 of Detrended Fluctuation Analysis (DFA-alpha1), has been shown to change with endurance exercise intensity. Its unique advantage is that it provides information about current absolute exercise intensity without prior lactate or gas exchange testing. Therefore, real-time assessment of this metric during field conditions using a wearable monitoring device could directly provide a valuable exercise intensity distribution without prior laboratory testing for different applied field settings in endurance sports. Until of late no mobile based product could display DFA-alpha1 in real-time using off the shelf consumer products. Recently an app designed for iOS and Android devices, HRV Logger, was updated to assess DFA-alpha1 in real-time. This brief research report illustrates the potential merits of real-time monitoring of this metric for the purposes of aerobic threshold (AT) estimation and exercise intensity demarcation between low (zone 1) and moderate (zone 2) in a former Olympic triathlete. In a single-case feasibility study, three practically relevant scenarios were successfully evaluated in cycling, (1) estimation of a HRV threshold (HRVT) as an adequate proxy for AT using Kubios HRV software via a typical cycling stage test, (2) estimation of the HRVT during real-time monitoring using a cycling 6 min stage test, (3) a simulated 1 h training ride with enforcement of low intensity boundaries and real-time HRVT confirmation. This single-case field evaluation illustrates the potential of an easy-to-use and low cost real-time estimation of the aerobic threshold and exercise intensity distribution using fractal correlation properties of HRV. Furthermore, this approach may enhance the translation of science into endurance sports practice for future real-world settings.
Collapse
Affiliation(s)
- Thomas Gronwald
- Faculty of Health Sciences, Department of Performance, Neuroscience, Therapy and Health, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany
| | - Sander Berk
- Dutch Triathlon Federation, Arnhem, Netherlands
| | - Marco Altini
- Faculty of Behavioral and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Laurent Mourot
- EA3920 Prognostic Factors and Regulatory Factors of Cardiac and Vascular Pathologies, Exercise Performance Health Innovation (EPHI) Platform, University of Bourgogne Franche-Comté, Besançon, France.,Division for Physical Education, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Olaf Hoos
- Center for Sports and Physical Education, Julius-Maximilians-University of Wuerzburg, Wuerzburg, Germany
| | - Bruce Rogers
- College of Medicine, University of Central Florida, Orlando, FL, United States
| |
Collapse
|
27
|
Rogers B, Giles D, Draper N, Mourot L, Gronwald T. Detection of the Anaerobic Threshold in Endurance Sports: Validation of a New Method Using Correlation Properties of Heart Rate Variability. J Funct Morphol Kinesiol 2021; 6:jfmk6020038. [PMID: 33925974 PMCID: PMC8167649 DOI: 10.3390/jfmk6020038] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/21/2021] [Accepted: 04/23/2021] [Indexed: 12/12/2022] Open
Abstract
Past attempts to define an anaerobic threshold (AnT) have relied upon gas exchange kinetics, lactate testing and field-based evaluations. DFA a1, an index of heart rate (HR) variability (HRV) fractal correlation properties, has been shown to decrease with exercise intensity. The intent of this study is to investigate whether the AnT derived from gas exchange is associated with the transition from a correlated to uncorrelated random HRV pattern signified by a DFA a1 value of 0.5. HRV and gas exchange data were obtained from 15 participants during an incremental treadmill run. Comparison of the HR reached at the second ventilatory threshold (VT2) was made to the HR reached at a DFA a1 value of 0.5 (HRVT2). Based on Bland-Altman analysis and linear regression, there was strong agreement between VT2 and HRVT2 measured by HR (r = 0.78, p < 0.001). Mean VT2 was reached at a HR of 174 (±12) bpm compared to mean HRVT2 at a HR of 171 (±16) bpm. In summary, the HR associated with a DFA a1 value of 0.5 on an incremental treadmill ramp was closely related to that of the HR at the VT2 derived from gas exchange analysis. A distinct numerical value of DFA a1 representing an uncorrelated, random interbeat pattern appears to be associated with the VT2 and shows potential as a noninvasive marker for training intensity distribution and performance status.
Collapse
Affiliation(s)
- Bruce Rogers
- College of Medicine, University of Central Florida, 6850 Lake Nona Boulevard, Orlando, FL 32827-7408, USA
- Correspondence:
| | - David Giles
- Lattice Training Ltd., Chesterfield S41 9AT, UK;
| | - Nick Draper
- School of Health Sciences, College of Education, Health and Human Development, University of Canterbury, 8041 Christchurch, New Zealand;
| | - Laurent Mourot
- EA3920 Prognostic Factors and Regulatory Factors of Cardiac and Vascular Pathologies, Exercise Performance Health Innovation (EPHI) Platform, University of Bourgogne Franche-Comté, 25000 Besançon, France;
- Division for Physical Education, National Research Tomsk Polytechnic University, Lenin Ave, 30, 634050 Tomsk Oblast, Russia
| | - Thomas Gronwald
- Department of Performance, Neuroscience, Therapy and Health, Faculty of Health Sciences, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Am Kaiserkai 1, 20457 Hamburg, Germany;
| |
Collapse
|