dos Santos TTS, Marques AP, Monteiro LCP, Santos EGDR, Pinto GHL, Belgamo A, Costa e Silva ADA, Cabral ADS, Kuliś S, Gajewski J, Souza GS, da Silva TJ, da Costa WTA, Salomão RC, Callegari B. Intra and Inter-Device Reliabilities of the Instrumented Timed-Up and Go Test Using Smartphones in Young Adult Population. SENSORS (BASEL, SWITZERLAND) 2024; 24:2918. [PMID: 38733024 PMCID: PMC11086236 DOI: 10.3390/s24092918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 03/19/2024] [Accepted: 03/20/2024] [Indexed: 05/13/2024]
Abstract
The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.
Collapse
Affiliation(s)
| | - Amélia Pasqual Marques
- Department of Physiotherapy, Speech Therapy and Occupational Therapy, Faculty of Medicine, University of São Paulo, São Paulo 05403-000, SP, Brazil;
| | - Luis Carlos Pereira Monteiro
- Instituto de Ciências Biológicas, Universidade Federal do Pará, Belém 66075-110, PA, Brazil; (L.C.P.M.); (G.S.S.)
| | - Enzo Gabriel da Rocha Santos
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Gustavo Henrique Lima Pinto
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Anderson Belgamo
- Instituto Federal de São Paulo, Piracicaba 17607-220, SP, Brazil;
| | - Anselmo de Athayde Costa e Silva
- Programa de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil;
| | - André dos Santos Cabral
- Centro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Tv. Perebebuí, 2623-Marco, Belém 66087-662, PA, Brazil;
| | - Szymon Kuliś
- Faculty of Rehabilitation, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34, 00-968 Warsaw, Poland;
| | - Jan Gajewski
- Faculty of Physical Education, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34, 00-968 Warsaw, Poland;
| | - Givago Silva Souza
- Instituto de Ciências Biológicas, Universidade Federal do Pará, Belém 66075-110, PA, Brazil; (L.C.P.M.); (G.S.S.)
- Núcleo de Medicina Tropical, Universidade Federal do Pará, Rua Augusto Corrêa 01, Belém 66075-110, PA, Brazil
| | - Tacyla Jesus da Silva
- Centro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil; (T.J.d.S.); (W.T.A.d.C.); (R.C.S.)
| | - Wesley Thyago Alves da Costa
- Centro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil; (T.J.d.S.); (W.T.A.d.C.); (R.C.S.)
| | - Railson Cruz Salomão
- Centro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil; (T.J.d.S.); (W.T.A.d.C.); (R.C.S.)
| | - Bianca Callegari
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil;
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| |
Collapse
|
2
|
Willingham TB, Stowell J, Collier G, Backus D. Leveraging Emerging Technologies to Expand Accessibility and Improve Precision in Rehabilitation and Exercise for People with Disabilities. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2024; 21:79. [PMID: 38248542 PMCID: PMC10815484 DOI: 10.3390/ijerph21010079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/20/2023] [Accepted: 12/28/2023] [Indexed: 01/23/2024]
Abstract
Physical rehabilitation and exercise training have emerged as promising solutions for improving health, restoring function, and preserving quality of life in populations that face disparate health challenges related to disability. Despite the immense potential for rehabilitation and exercise to help people with disabilities live longer, healthier, and more independent lives, people with disabilities can experience physical, psychosocial, environmental, and economic barriers that limit their ability to participate in rehabilitation, exercise, and other physical activities. Together, these barriers contribute to health inequities in people with disabilities, by disproportionately limiting their ability to participate in health-promoting physical activities, relative to people without disabilities. Therefore, there is great need for research and innovation focusing on the development of strategies to expand accessibility and promote participation in rehabilitation and exercise programs for people with disabilities. Here, we discuss how cutting-edge technologies related to telecommunications, wearables, virtual and augmented reality, artificial intelligence, and cloud computing are providing new opportunities to improve accessibility in rehabilitation and exercise for people with disabilities. In addition, we highlight new frontiers in digital health technology and emerging lines of scientific research that will shape the future of precision care strategies for people with disabilities.
Collapse
Affiliation(s)
- T. Bradley Willingham
- Shepherd Center, Virginia C. Crawford Research Institute, Atlanta, GA 30309, USA (D.B.)
- Department of Physical Therapy, Georgia State University, Atlanta, GA 30302, USA
| | - Julie Stowell
- Shepherd Center, Virginia C. Crawford Research Institute, Atlanta, GA 30309, USA (D.B.)
- Department of Physical Therapy, Georgia State University, Atlanta, GA 30302, USA
| | - George Collier
- Shepherd Center, Virginia C. Crawford Research Institute, Atlanta, GA 30309, USA (D.B.)
| | - Deborah Backus
- Shepherd Center, Virginia C. Crawford Research Institute, Atlanta, GA 30309, USA (D.B.)
| |
Collapse
|
3
|
Cerfoglio S, Capodaglio P, Rossi P, Conforti I, D'Angeli V, Milani E, Galli M, Cimolin V. Evaluation of Upper Body and Lower Limbs Kinematics through an IMU-Based Medical System: A Comparative Study with the Optoelectronic System. SENSORS (BASEL, SWITZERLAND) 2023; 23:6156. [PMID: 37448005 DOI: 10.3390/s23136156] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/23/2023] [Accepted: 06/29/2023] [Indexed: 07/15/2023]
Abstract
In recent years, the use of inertial-based systems has been applied to remote rehabilitation, opening new perspectives for outpatient assessment. In this study, we assessed the accuracy and the concurrent validity of the angular measurements provided by an inertial-based device for rehabilitation with respect to the state-of-the-art system for motion tracking. Data were simultaneously collected with the two systems across a set of exercises for trunk and lower limbs, performed by 21 healthy participants. Additionally, the sensitivity of the inertial measurement unit (IMU)-based system to its malpositioning was assessed. Root mean square error (RMSE) was used to explore the differences in the outputs of the two systems in terms of range of motion (ROM), and their agreement was assessed via Pearson's correlation coefficient (PCC) and Lin's concordance correlation coefficient (CCC). The results showed that the IMU-based system was able to assess upper-body and lower-limb kinematics with a mean error in general lower than 5° and that its measurements were moderately biased by its mispositioning. Although the system does not seem to be suitable for analysis requiring a high level of detail, the findings of this study support the application of the device in rehabilitation programs in unsupervised settings, providing reliable data to remotely monitor the progress of the rehabilitation pathway and change in patient's motor function.
Collapse
Affiliation(s)
- Serena Cerfoglio
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Orthopaedic Rehabilitation Unit and Research Laboratory in Biomechanics, Rehabilitation and Ergonomics, San Giuseppe Hospital, IRCCS Istituto Auxologico Italiano, Strada Luigi Cadorna 90, 28824 Piancavallo, Italy
| | - Paolo Capodaglio
- Orthopaedic Rehabilitation Unit and Research Laboratory in Biomechanics, Rehabilitation and Ergonomics, San Giuseppe Hospital, IRCCS Istituto Auxologico Italiano, Strada Luigi Cadorna 90, 28824 Piancavallo, Italy
- Department of Surgical Sciences, Physical Medicine and Rehabilitation, University of Turin, 10126 Turin, Italy
| | - Paolo Rossi
- Clinica Hildebrand, Centro di Riabilitazione Brissago, Via Crodolo 18, 6614 Brissago, Switzerland
| | - Ilaria Conforti
- Euleria Health Società Benefit Rovereto, 38068 Trento, Italy
| | | | - Elia Milani
- Euleria Health Società Benefit Rovereto, 38068 Trento, Italy
| | - Manuela Galli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Veronica Cimolin
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Orthopaedic Rehabilitation Unit and Research Laboratory in Biomechanics, Rehabilitation and Ergonomics, San Giuseppe Hospital, IRCCS Istituto Auxologico Italiano, Strada Luigi Cadorna 90, 28824 Piancavallo, Italy
| |
Collapse
|
4
|
Rum L, Sciarra T, Balletti N, Lazich A, Bergamini E. Validation of an Automatic Inertial Sensor-Based Methodology for Detailed Barbell Velocity Monitoring during Maximal Paralympic Bench Press. SENSORS (BASEL, SWITZERLAND) 2022; 22:9904. [PMID: 36560273 PMCID: PMC9784026 DOI: 10.3390/s22249904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 12/12/2022] [Accepted: 12/15/2022] [Indexed: 06/17/2023]
Abstract
Current technologies based on inertial measurement units (IMUs) are considered valid and reliable tools for monitoring barbell velocity in strength training. However, the extracted outcomes are often limited to a few velocity metrics, such as mean or maximal velocity. This study aimed at validating a single IMU-based methodology to automatically obtain the barbell velocity full profile as well as key performance metrics during maximal Paralympic bench press. Seven Paralympic powerlifters (age: 30.5 ± 4.3 years, sitting height: 71.6 ± 6.8 cm, body mass: 72.5 ± 16.4 kg, one-repetition maximum: 148.4 ± 38.6 kg) performed four attempts of maximal Paralympic bench press. The barbell velocity profile and relevant metrics were automatically obtained from IMU linear acceleration through a custom-made algorithm and validated against a video-based reference system. The mean difference between devices was 0.00 ± 0.04 m·s−1 with low limits of agreement (<0.09 m·s−1) and moderate-to-good reliability (ICC: 0.55−0.90). Linear regression analysis showed large-to-very large associations between paired measurements (r: 0.57−0.91, p < 0.003; SEE: 0.02−0.06 m·s−1). The analysis of velocity curves showed a high spatial similarity and small differences between devices. The proposed methodology provided a good level of agreement, making it suitable for different applications in barbell velocity monitoring during maximal Paralympic bench press.
Collapse
Affiliation(s)
- Lorenzo Rum
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. De Bosis 6, 00135 Rome, Italy
| | - Tommaso Sciarra
- Defense Veterans Center, Celio Army Medical Center, 00184 Rome, Italy
| | - Nicoletta Balletti
- Defense Veterans Center, Celio Army Medical Center, 00184 Rome, Italy
- Department of Biosciences and Territory, University of Molise, 86100 Campobasso, Italy
| | - Aldo Lazich
- Defense Veterans Center, Celio Army Medical Center, 00184 Rome, Italy
- DIAG, Sapienza University of Rome, 00185 Roma, Italy
| | - Elena Bergamini
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. De Bosis 6, 00135 Rome, Italy
| |
Collapse
|
5
|
Duarte MB, da Costa Moraes AA, Ferreira EV, da Silva Almeida GC, Cabral ADS, de Athayde Costa e Silva A, Garcez DR, da Silva Souza G, Callegari B. Wearable Inertial Sensor Approach for Postural Adjustment Assessments during Predictable Perturbations in Sport. SENSORS (BASEL, SWITZERLAND) 2022; 22:8272. [PMID: 36365967 PMCID: PMC9655386 DOI: 10.3390/s22218272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 09/12/2022] [Accepted: 09/21/2022] [Indexed: 06/16/2023]
Abstract
INTRODUCTION Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. OBJECTIVES This article aimed to test the validity and reliability of signals extracted from the sensor's accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). DESIGN Observational, cross-sectional study. METHODS We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). RESULTS The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. CONCLUSIONS Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.
Collapse
Affiliation(s)
- Manuela Brito Duarte
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
| | | | - Eduardo Veloso Ferreira
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
| | | | - André dos Santos Cabral
- Centro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Tv. Perebebuí, 2623—Marco, Belém 66087-662, PA, Brazil
| | - Anselmo de Athayde Costa e Silva
- Programa de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
| | - Daniela Rosa Garcez
- University Hospital Bettina Ferro de Souza, Federal University of Pará, R. Augusto Corrêa, n1, Belém 66075-110, PA, Brazil
| | - Givago da Silva Souza
- Instituto de Ciências Biológicas, Universidade Federal do Pará, Rua Augusto Corrêa 01, Belém 66075-110, PA, Brazil
- Núcleo de Medicina Tropical, Universidade Federal do Pará, Avenida Generalíssimo Deodoro 92, Belém 66055-240, PA, Brazil
| | - Bianca Callegari
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
- Programa de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
- Núcleo de Medicina Tropical, Universidade Federal do Pará, Avenida Generalíssimo Deodoro 92, Belém 66055-240, PA, Brazil
| |
Collapse
|
6
|
Duarte MB, da Costa Moraes AA, Ferreira EV, da Silva Almeida GC, da Rocha Santos EG, Pinto GHL, de Oliveira PR, Amorim CF, Dos Santos Cabral A, Saunier G, Costa E Silva ADA, Belgamo A, Souza GDS, Callegari B. Validity and reliability of a smartphone-based assessment for anticipatory and compensatory postural adjustments during predictable perturbations. Gait Posture 2022; 96:9-17. [PMID: 35533431 DOI: 10.1016/j.gaitpost.2022.05.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/26/2022] [Accepted: 05/02/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUND Postural adjustments involve displacements of the center of mass (COM), controlled by the central nervous system (CNS), to maintain equilibrium whilst standing. Postural adjustments can be anticipatory (APAs) or compensatory (CPAs), and are triggered to counteract predictable perturbations. RESEARCH QUESTION Is the new smartphone application, Momentum, a valid and reliable tool for the assessment of body balance, by measuring APAs and CPAs using accelerometer readings? METHODS 20 young adults were exposed to external predictable perturbations induced at the shoulder level, whilst standing. COM linear acceleration was recorded by Momentum (extracting data from a smartphone's accelerometer) and a 3D motion capture system. RESULTS The key results demonstrated a very high, significant correlation (r ≥ 0.7, p < 0.05) between the two device settings in the APA parameters, which obtained r = 0.65, denoting a high correlation. Considering the reliability, variables that are compensatory in nature are presented on a scale of good to excellent in measurement methods, kinematics, and Momentum. However, the anticipatory variables presented excellent reliability only for the kinematics. SIGNIFICANCE These experiments show that Momentum is a valid method for measuring COM acceleration under predictable perturbations and is reliable for compensatory events.
Collapse
Affiliation(s)
- Manuela Brito Duarte
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo deodoro 01, Belém 66073-00, PA, Brazil.
| | | | - Eduardo Veloso Ferreira
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo deodoro 01, Belém 66073-00, PA, Brazil.
| | | | - Enzo Gabriel da Rocha Santos
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil
| | - Gustavo Henrique Lima Pinto
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil
| | - Paulo Rui de Oliveira
- Doctoral and Masters Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo, SP, Brazil.
| | - César Ferreira Amorim
- Doctoral and Masters Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo, SP, Brazil; Département des Sciences de la Santé, Programme de physiothérapie de l'université McGill offert en extension à l'UQAC, Saguenay, Québec, Canada; Physical Therapy and Neuroscience Departments, Wertheims' Colleges of Nursing and Health Sciences and Medicine, Florida International University (FIU), Miami, FL, United States
| | - André Dos Santos Cabral
- Centro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Tv. Perebebuí, 2623 - Marco, Belém, PA 66087-662, Brazil.
| | - Ghislain Saunier
- Laboratório de Cognição Motora, Departamento de Anatomia, Universidade Federal do Pará, Rua Augusto Corrêa 01, Belém 66075-110, PA, Brazil.
| | - Anselmo de Athayde Costa E Silva
- Programa de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo deodoro 01, Belém 66073-00, PA, Brazil.
| | - Anderson Belgamo
- Departamento de Ciência da Computação, Instituto Federal de São Paulo, Piracicaba, Brazil.
| | - Givago da Silva Souza
- Instituto de Ciências Biológicas, Universidade Federal do Pará, Rua Augusto Corrêa 01, Belém 66075-110, PA, Brazil.
| | - Bianca Callegari
- Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo deodoro 01, Belém 66073-00, PA, Brazil; Programa de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo deodoro 01, Belém 66073-00, PA, Brazil.
| |
Collapse
|
7
|
da Costa Moraes AA, Duarte MB, Ferreira EV, da Silva Almeida GC, da Rocha Santos EG, Pinto GHL, de Oliveira PR, Amorim CF, Cabral ADS, de Athayde Costa e Silva A, Souza GS, Callegari B. Validity and Reliability of Smartphone App for Evaluating Postural Adjustments during Step Initiation. SENSORS (BASEL, SWITZERLAND) 2022; 22:2935. [PMID: 35458920 PMCID: PMC9030467 DOI: 10.3390/s22082935] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/17/2022] [Accepted: 03/03/2022] [Indexed: 06/14/2023]
Abstract
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland−Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.
Collapse
Affiliation(s)
- Anderson Antunes da Costa Moraes
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Manuela Brito Duarte
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Eduardo Veloso Ferreira
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Gizele Cristina da Silva Almeida
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Enzo Gabriel da Rocha Santos
- Institute of Exact and Natural Sciences, Federal University of Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Gustavo Henrique Lima Pinto
- Institute of Exact and Natural Sciences, Federal University of Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Paulo Rui de Oliveira
- Doctoral and Master’s Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo 03071-000, SP, Brazil; (P.R.d.O.); (C.F.A.)
| | - César Ferreira Amorim
- Doctoral and Master’s Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo 03071-000, SP, Brazil; (P.R.d.O.); (C.F.A.)
- Département des Sciences de la Santé, Programme de Physiothérapie de L’université McGill Offert en Extension à l’UQAC, Saguenay, QC G7H 2B1,Canada
- Physical Therapy and Neuroscience Departments, Wertheims’ Colleges of Nursing and Health Sciences and Medicine, Florida International University (FIU), Miami, FL 33199, USA
| | - André dos Santos Cabral
- Center for Biological and Health Sciences, Pará State University, Tv. Perebebuí, 2623—Marco, Belém 66087-662, PA, Brazil;
| | - Anselmo de Athayde Costa e Silva
- Postgraduate Program in Movement Science, Federal University of Pará, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil;
| | - Givago Silva Souza
- Institute of Biological Sciences, Federal University of Pará, R. Augusto Corrêa 01, Belém 66075-110, PA, Brazil;
- Tropical Medicine Nucleus, Federal University of Pará, Avenida Generalíssimo Deodoro 92, Belém 66055-240, PA, Brazil
| | - Bianca Callegari
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| |
Collapse
|
8
|
Fritschi R, Seiler J, Gross M. Validity and Effects of Placement of Velocity-Based Training Devices. Sports (Basel) 2021; 9:sports9090123. [PMID: 34564328 PMCID: PMC8472848 DOI: 10.3390/sports9090123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 11/16/2022] Open
Abstract
Velocity-based training (VBT) is a resistance training method by which training variables are manipulated based on kinematic outcomes, e.g., barbell velocity. The better precision for monitoring and manipulating training variables ascribed to VBT assumes that velocity is measured and communicated correctly. This study assessed the validity of several mobile and one stationary VBT device for measuring mean and peak concentric barbell velocity over a range of velocities and exercises, including low- and high-velocity, ballistic and non-ballistic, and plyometric and non-plyometric movements, and to quantify the isolated effect of device attachment point on measurement validity. GymAware (r = 0.90-1, standard error of the estimate, SEE = 0.01-0.08 m/s) and Quantum (r = 0.88-1, SEE = 0.01-0.18 m/s) were most valid for mean and peak velocity, with Vmaxpro (r = 0.92-0.99, SEE = 0.02-0.13 m/s) close behind. Push (r = 0.69-0.96, SEE = 0.03-0.17 m/s) and Flex (r = 0.60-0.94, SEE = 0.02-0.19 m/s) showed poorer validity (especially for higher-velocity exercises), although typical errors for mean velocity in exercises other than hang power snatch were acceptable. Effects of device placement were detectable, yet likely small enough (SEE < 0.1 m/s) to be negligible in training settings.
Collapse
Affiliation(s)
- Raphael Fritschi
- Department of Medicine, Movement and Sport Science, University of Fribourg, 1700 Fribourg, Switzerland;
| | - Jan Seiler
- Department for Elite Sport, Swiss Federal Institute of Sport Magglingen (SFISM), Hauptstrasse 247, 2532 Magglingen, Switzerland;
| | - Micah Gross
- Department for Elite Sport, Swiss Federal Institute of Sport Magglingen (SFISM), Hauptstrasse 247, 2532 Magglingen, Switzerland;
- Correspondence:
| |
Collapse
|
9
|
Clemente FM, Akyildiz Z, Pino-Ortega J, Rico-González M. Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review. SENSORS 2021; 21:s21072511. [PMID: 33916801 PMCID: PMC8038306 DOI: 10.3390/s21072511] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 03/29/2021] [Accepted: 04/01/2021] [Indexed: 12/14/2022]
Abstract
The use of inertial measurement unit (IMU) has become popular in sports assessment. In the case of velocity-based training (VBT), there is a need to measure barbell velocity in each repetition. The use of IMUs may make the monitoring process easier; however, its validity and reliability should be established. Thus, this systematic review aimed to (1) identify and summarize studies that have examined the validity of wearable wireless IMUs for measuring barbell velocity and (2) identify and summarize studies that have examined the reliability of IMUs for measuring barbell velocity. A systematic review of Cochrane Library, EBSCO, PubMed, Scielo, Scopus, SPORTDiscus, and Web of Science databases was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. From the 161 studies initially identified, 22 were fully reviewed, and their outcome measures were extracted and analyzed. Among the eight different IMU models, seven can be considered valid and reliable for measuring barbell velocity. The great majority of IMUs used for measuring barbell velocity in linear trajectories are valid and reliable, and thus can be used by coaches for external load monitoring.
Collapse
Affiliation(s)
- Filipe Manuel Clemente
- Instituto Politécnico de Viana do Castelo, Escola Superior Desporto e Lazer, Rua Escola Industrial e Comercial de Nun’Álvares, 4900-347 Viana do Castelo, Portugal
- Instituto de Telecomunicações, Delegação da Covilhã, 1049-001 Lisboa, Portugal
- Correspondence:
| | - Zeki Akyildiz
- Sports Science Department, Gazi University, Teknikokullar, Ankara 06500, Turkey;
| | - José Pino-Ortega
- Faculty of Sports Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
- BIOVETMED & SPORTSCI Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
| | - Markel Rico-González
- BIOVETMED & SPORTSCI Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, San Javier, 30100 Murcia, Spain;
- Department of Physical Education and Sport, University of the Basque Country, UPV-EHU, Lasarte 71, 01007 Vitoria-Gasteiz, Spain
| |
Collapse
|
10
|
Weakley J, Morrison M, García-Ramos A, Johnston R, James L, Cole MH. The Validity and Reliability of Commercially Available Resistance Training Monitoring Devices: A Systematic Review. Sports Med 2021; 51:443-502. [PMID: 33475985 PMCID: PMC7900050 DOI: 10.1007/s40279-020-01382-w] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/29/2020] [Indexed: 01/04/2023]
Abstract
Background Monitoring resistance training has a range of unique difficulties due to differences in physical characteristics and capacity between athletes, and the indoor environment in which it often occurs. Traditionally, methods such as volume load have been used, but these have inherent flaws. In recent times, numerous portable and affordable devices have been made available that purport to accurately and reliably measure kinetic and kinematic outputs, potentially offering practitioners a means of measuring resistance training loads with confidence. However, a thorough and systematic review of the literature describing the reliability and validity of these devices has yet to be undertaken, which may lead to uncertainty from practitioners on the utility of these devices. Objective A systematic review of studies that investigate the validity and/or reliability of commercially available devices that quantify kinetic and kinematic outputs during resistance training. Methods Following PRISMA guidelines, a systematic search of SPORTDiscus, Web of Science, and Medline was performed; studies included were (1) original research investigations; (2) full-text articles written in English; (3) published in a peer-reviewed academic journal; and (4) assessed the validity and/or reliability of commercially available portable devices that quantify resistance training exercises. Results A total of 129 studies were retrieved, of which 47 were duplicates. The titles and abstracts of 82 studies were screened and the full text of 40 manuscripts were assessed. A total of 31 studies met the inclusion criteria. Additional 13 studies, identified via reference list assessment, were included. Therefore, a total of 44 studies were included in this review. Conclusion Most of the studies within this review did not utilise a gold-standard criterion measure when assessing validity. This has likely led to under or overreporting of error for certain devices. Furthermore, studies that have quantified intra-device reliability have often failed to distinguish between technological and biological variability which has likely altered the true precision of each device. However, it appears linear transducers which have greater accuracy and reliability compared to other forms of device. Future research should endeavour to utilise gold-standard criterion measures across a broader range of exercises (including weightlifting movements) and relative loads. Electronic supplementary material The online version of this article (10.1007/s40279-020-01382-w) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Jonathon Weakley
- School of Behavioural and Health Sciences, Australian Catholic University, Building 211.1.26, Brisbane, QLD, Australia. .,Carnegie Applied Rugby Research (CARR) Centre, Institute of Sport, Physical Activity and Leisure, Leeds Beckett University, Leeds, UK.
| | - Matthew Morrison
- School of Behavioural and Health Sciences, Australian Catholic University, Building 211.1.26, Brisbane, QLD, Australia
| | - Amador García-Ramos
- Department of Sports Sciences and Physical Conditioning, Universidad Católica de la Santísima Concepción, Concepción, Chile.,Department of Physical Education and Sport, University of Granada, Granada, Spain
| | - Rich Johnston
- School of Behavioural and Health Sciences, Australian Catholic University, Building 211.1.26, Brisbane, QLD, Australia.,Carnegie Applied Rugby Research (CARR) Centre, Institute of Sport, Physical Activity and Leisure, Leeds Beckett University, Leeds, UK
| | - Lachlan James
- Sport and Exercise Science, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, Australia
| | - Michael H Cole
- School of Behavioural and Health Sciences, Australian Catholic University, Building 211.1.26, Brisbane, QLD, Australia
| |
Collapse
|