1
|
Sekiguchi M, Kishida Y, Ikematsu H, Konno M, Mizuguchi Y, Hotta K, Imai K, Ito S, Takada K, Shiomi A, Yasui H, Tsukamoto S, Hirano H, Kobayashi N, Saito Y, Inaba A, Shinmura K, Konishi J, Ozawa H, Fujita S, Murakami Y, Matsuda T. Proportions and characteristics of interval cancer in annual fecal immunochemical test screening and postcolonoscopy colorectal cancer: Results from a Japanese multicenter prospective study using questionnaires, the C-DETECT study. Dig Endosc 2024; 36:1140-1151. [PMID: 38433322 DOI: 10.1111/den.14772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 01/28/2024] [Indexed: 03/05/2024]
Abstract
OBJECTIVES There are several types of colorectal cancer (CRC) according to the detection methods and intervals, including interval CRC (iCRC) and postcolonoscopy CRC (PCCRC). We aimed to examine their proportions and characteristics. METHODS We conducted a multicenter prospective study using questionnaires in Japan ("C-DETECT study"), in which differences in CRC characteristics according to detection methods and intervals were examined from consecutive adult patients. Because the annual fecal immunochemical test (FIT) was used in population-based screening, the annual FIT-iCRC was assessed. RESULTS In total, 1241 CRC patients (1064 with invasive CRC) were included. Annual FIT-iCRC (a), 3-year PCCRC (b), and CRC detected within 1 year after a positive FIT with noncompliance to colonoscopy (c) accounted for 4.5%, 7.0%, and 3.9% of all CRCs, respectively, and for 3.9%, 5.4%, and 4.3% of invasive CRCs, respectively. The comparison among these (a, b, c) and other CRCs (d) demonstrated differences in the proportions of ≥T2 invasion ([a] 58.9%, [b] 44.8%, [c] 87.5%, [d] 73.0%), metastasis ([a] 33.9%, [b] 21.8%, [c] 54.2%, [d] 43.9%), right-sided CRC ([a] 42.9%, [b] 40.2%, [c] 18.8%, [d] 28.6%), and female sex ([a] 53.6%, [b] 49.4%, [c] 27.1%, [d] 41.6%). In metastatic CRC, (a) and (b) showed a higher proportions of BRAF mutations ([a] [b] 12.0%, [c] [d] 3.1%). CONCLUSIONS Annual FIT-iCRC and 3-year PCCRC existed in nonnegligible proportions. They were characterized by higher proportions of right-sided tumors, female sex, and BRAF mutations. These findings suggest that annual FIT-iCRC and 3-year PCCRC may have biological features different from those of other CRCs.
Collapse
Affiliation(s)
- Masau Sekiguchi
- Cancer Screening Center, National Cancer Center Hospital, Tokyo, Japan
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
- Division of Screening Technology, National Cancer Center Institute for Cancer Control, Tokyo, Japan
| | | | - Hiroaki Ikematsu
- Department of Gastroenterology and Endoscopy, National Cancer Center Hospital East, Chiba, Japan
| | - Maki Konno
- Department of Gastroenterology, Tochigi Cancer Center, Tochigi, Japan
| | | | - Kinichi Hotta
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kenichiro Imai
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Sayo Ito
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kazunori Takada
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Akio Shiomi
- Division of Colorectal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| | - Hirofumi Yasui
- Division of Gastrointestinal Oncology, Shizuoka Cancer Center, Shizuoka, Japan
| | - Shunsuke Tsukamoto
- Department of Colorectal Surgery, National Cancer Center Hospital, Tokyo, Japan
| | - Hidekazu Hirano
- Department of Gastrointestinal Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Nozomu Kobayashi
- Cancer Screening Center, National Cancer Center Hospital, Tokyo, Japan
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
- Division of Screening Technology, National Cancer Center Institute for Cancer Control, Tokyo, Japan
| | - Yutaka Saito
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
| | - Atsushi Inaba
- Department of Gastroenterology and Endoscopy, National Cancer Center Hospital East, Chiba, Japan
| | - Kensuke Shinmura
- Department of Gastroenterology and Endoscopy, National Cancer Center Hospital East, Chiba, Japan
| | - Jun Konishi
- Department of Gastroenterology, Tochigi Cancer Center, Tochigi, Japan
| | - Heita Ozawa
- Department of Surgery, Tochigi Cancer Center, Tochigi, Japan
| | - Shin Fujita
- Department of Surgery, Tochigi Cancer Center, Tochigi, Japan
| | | | - Takahisa Matsuda
- Division of Gastroenterology and Hepatology, Toho University Omori Medical Center, Tokyo, Japan
| |
Collapse
|
2
|
Lopes SR, Martins C, Santos IC, Teixeira M, Gamito É, Alves AL. Colorectal cancer screening: A review of current knowledge and progress in research. World J Gastrointest Oncol 2024; 16:1119-1133. [PMID: 38660635 PMCID: PMC11037045 DOI: 10.4251/wjgo.v16.i4.1119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/16/2024] [Accepted: 02/18/2024] [Indexed: 04/10/2024] Open
Abstract
Colorectal cancer (CRC) is one of the most prevalent malignancies worldwide, being the third most commonly diagnosed malignancy and the second leading cause of cancer-related deaths globally. Despite the progress in screening, early diagnosis, and treatment, approximately 20%-25% of CRC patients still present with metastatic disease at the time of their initial diagnosis. Furthermore, the burden of disease is still expected to increase, especially in individuals younger than 50 years old, among whom early-onset CRC incidence has been increasing. Screening and early detection are pivotal to improve CRC-related outcomes. It is well established that CRC screening not only reduces incidence, but also decreases deaths from CRC. Diverse screening strategies have proven effective in decreasing both CRC incidence and mortality, though variations in efficacy have been reported across the literature. However, uncertainties persist regarding the optimal screening method, age intervals and periodicity. Moreover, adherence to CRC screening remains globally low. In recent years, emerging technologies, notably artificial intelligence, and non-invasive biomarkers, have been developed to overcome these barriers. However, controversy exists over the actual impact of some of the new discoveries on CRC-related outcomes and how to effectively integrate them into daily practice. In this review, we aim to cover the current evidence surrounding CRC screening. We will further critically assess novel approaches under investigation, in an effort to differentiate promising innovations from mere novelties.
Collapse
Affiliation(s)
- Sara Ramos Lopes
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| | - Claudio Martins
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| | - Inês Costa Santos
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| | - Madalena Teixeira
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| | - Élia Gamito
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| | - Ana Luisa Alves
- Department of Gastroenterology, Centro Hospitalar de Setúbal, Setúbal 2910-446, Portugal
| |
Collapse
|
3
|
Vanaclocha-Espí M, Pinto-Carbó M, Ibáñez J, Valverde-Roig MJ, Portillo I, Pérez-Riquelme F, de la Vega M, Castán-Cameo S, Salas D, Molina-Barceló A. Interval Cancer in Population-Based Colorectal Screening Programmes: Incidence and Characteristics of Tumours. Cancers (Basel) 2024; 16:769. [PMID: 38398160 PMCID: PMC10887036 DOI: 10.3390/cancers16040769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 02/06/2024] [Accepted: 02/08/2024] [Indexed: 02/25/2024] Open
Abstract
The objective of this study is to evaluate interval cancer (IC) in colorectal cancer (CRC) screening, which is CRC diagnosed in an individual after having received a negative faecal occult blood test and before the next invitation to participate in screening. A follow-up study was conducted on a cohort of participants in the first three screening rounds of four colorectal cancer screening programmes in Spain, n = 664,993. A total of 321 ICs and 2120 screen-detected cancers (SCs) were found. The IC and SC rates were calculated for each guaiac (gFOBT) or immunochemical (FIT) test. A Cox regression model was used to estimate the hazard ratios (HR) of IC risk factors. A nested case-control study was carried out to compare IC and SC tumour characteristics. The IC rate was 1.16‱ with the gFOBT and 0.35‱ with the FIT. Men and people aged 60-69 showed an increased probability of IC (HR = 1.81 and HR = 1.95, respectively). There was a decreased probability of IC in individuals who regularly participated in screening, HR = 0.62 (0.47-0.82). IC risk gradually rose as the amount of Hb detected in the FIT increased. IC tumours were in more advanced stages and of a larger size than SC tumours, and they were mostly located in the cecum. These results may play a key role in future strategies for screening programmes, reducing IC incidence.
Collapse
Affiliation(s)
- Mercedes Vanaclocha-Espí
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Community (FISABIO)–Public Health, 46020 Valencia, Spain (A.M.-B.)
| | - Marina Pinto-Carbó
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Community (FISABIO)–Public Health, 46020 Valencia, Spain (A.M.-B.)
| | - Josefa Ibáñez
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Community (FISABIO)–Public Health, 46020 Valencia, Spain (A.M.-B.)
- General Directorate of Public Health, Valencian Community, 46020 Valencia, Spain
| | | | | | | | - Mariola de la Vega
- General Directorate of Assistance Programmes, 38071 Santa Cruz de Tenerife, Spain
| | - Susana Castán-Cameo
- General Directorate of Public Health, Valencian Community, 46020 Valencia, Spain
| | - Dolores Salas
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Community (FISABIO)–Public Health, 46020 Valencia, Spain (A.M.-B.)
- General Directorate of Public Health, Valencian Community, 46020 Valencia, Spain
| | - Ana Molina-Barceló
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Community (FISABIO)–Public Health, 46020 Valencia, Spain (A.M.-B.)
| |
Collapse
|
4
|
Saw KS, Sexton K, Frankish P, Hulme-Moir M, Bissett I, Parry S. Interval colorectal cancers after negative faecal immunochemical test in the New Zealand Bowel Screening Pilot. BMJ Open Gastroenterol 2023; 10:e001233. [PMID: 38007223 PMCID: PMC10679982 DOI: 10.1136/bmjgast-2023-001233] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 11/02/2023] [Indexed: 11/27/2023] Open
Abstract
OBJECTIVE Evaluate the diagnostic performance of faecal immunochemical test (FIT), identify risk factors for FIT-interval colorectal cancers (FIT-IC) and describe long-term outcomes of participants with colorectal cancers (CRC) in the New Zealand Bowel Screening Pilot (BSP). DESIGN From 2012 to 2017, the BSP offered eligible individuals, aged 50-74 years, biennial screening using a quantitative FIT with positivity threshold of 15 µg haemoglobin (Hb)/g faeces. Retrospective review of prospectively maintained data extracted from the BSP Register and New Zealand Cancer Registry identified any CRC reported in participants who returned a definitive FIT result. Further details were obtained from hospital records. FIT-ICs were primary CRC diagnosed within 24 months of a negative FIT. Factors associated with FIT-ICs were identified using logistic regression. RESULTS Of 387 215 individuals invited, 57.4% participated with 6.1% returning positive FIT results. Final analysis included 520 CRC, of which 111 (21.3%) met FIT-IC definition. Overall FIT sensitivity for CRC was 78.7% (95% CI=74.9% to 82.1%), specificity was 94.1% (95% CI=94.0% to 94.2%). In 78 (70.3%) participants with FIT-IC, faecal Hb was reported as undetectable. There were no significant associations between FIT-IC and age, sex, ethnicity and deprivation. FIT-ICs were significantly associated with proximal tumour location, late stage at diagnosis, high-grade tumour differentiation and subsequent round screens. Median follow-up time was 74 (2-124) months. FIT-IC had significantly poorer overall survival. CONCLUSION FIT sensitivity in BSP compared favourably to published data. FIT-ICs were more likely to be proximal tumours with poor long-term outcomes. Further lowering of FIT threshold would have minimal impact on FIT-IC.
Collapse
Affiliation(s)
- Kai Sheng Saw
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Kerry Sexton
- National Screening Unit, New Zealand Ministry of Health, Wellington, New Zealand
| | - Paul Frankish
- Department of Gastroenterology, Te Whatu Ora - Health New Zealand Waitemata, Takapuna, New Zealand
| | - Mike Hulme-Moir
- Department of Surgery, Te Whatu Ora - Health New Zealand Waitemata, Takapuna, New Zealand
| | - Ian Bissett
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Susan Parry
- National Screening Unit, New Zealand Ministry of Health, Wellington, New Zealand
- Department of Medicine, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
5
|
Hou JY, Li N, Wang J, Gao LJ, Chang JS, Cao JM. Histone crotonylation of peripheral blood mononuclear cells is a potential biomarker for diagnosis of colorectal cancer. Epigenetics Chromatin 2023; 16:35. [PMID: 37749610 PMCID: PMC10521402 DOI: 10.1186/s13072-023-00509-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 09/17/2023] [Indexed: 09/27/2023] Open
Abstract
BACKGROUND Blood-based tests have public appeal in screening cancers due to their minimally invasive nature, ability to integrate with other routine blood tests, and high compliance. This study aimed to investigate whether certain epigenetic modulation of peripheral blood mononuclear cells (PBMCs) could be a biomarker of colorectal cancer (CRC). RESULTS Western blotting of histones in the PBMCs from 40 colorectal cancer patients and 40 healthy controls was performed to identify the crotonylation sites of proteins. The correlation of crotonylation with tumor staging and diagnostic efficacy were analyzed. Crotonylation of H2BK12 (H2BK12cr) was identified significantly upregulated in the PBMCs of CRC patients compared to healthy controls, and were closely related to distant metastasis (P = 0.0478) and late TNM stage (P = 0.0201). Receiver operator characteristic curve (ROC) analysis demonstrated that the area under curve (AUC) of H2BK12cr was 0.8488, the sensitivity was 70%, and the specificity was 92.5%. The H2BK12cr parameter significantly increased the diagnostic effectiveness of CRC compared with the commercial carcinoembryonic antigen assays. CONCLUSIONS The H2BK12cr level in PBMCs of CRC patients has a potential to be a biomarker for distinguishing CRC patients from healthy controls with the advantages of easy operation and high diagnostic efficacy.
Collapse
Affiliation(s)
- Jia-Yi Hou
- Department of Clinical Laboratory, Shanxi Provincial Academy of Traditional Chinese Medicine, Taiyuan, China
| | - Ning Li
- Department of Gastrointestinal and Pancreatic Surgery and Hernia and Abdominal Surgery, Shanxi Provincial People's Hospital, Taiyuan, China
| | - Jie Wang
- Key Laboratory of Cellular Physiology at Shanxi Medical University, Ministry of Education, Key Laboratory of Cellular Physiology of Shanxi Province, and the Department of Physiology, Shanxi Medical University, Taiyuan, China
| | - Li-Juan Gao
- Key Laboratory of Cellular Physiology at Shanxi Medical University, Ministry of Education, Key Laboratory of Cellular Physiology of Shanxi Province, and the Department of Physiology, Shanxi Medical University, Taiyuan, China
| | - Jia-Song Chang
- Key Laboratory of Cellular Physiology at Shanxi Medical University, Ministry of Education, Key Laboratory of Cellular Physiology of Shanxi Province, and the Department of Physiology, Shanxi Medical University, Taiyuan, China
| | - Ji-Min Cao
- Key Laboratory of Cellular Physiology at Shanxi Medical University, Ministry of Education, Key Laboratory of Cellular Physiology of Shanxi Province, and the Department of Physiology, Shanxi Medical University, Taiyuan, China.
| |
Collapse
|
6
|
Świtalski J, Tatara T, Wnuk K, Miazga W, Karauda D, Matera A, Jabłońska M, Jopek S, Religioni U, Gujski M. Clinical Effectiveness of Faecal Immunochemical Test in the Early Detection of Colorectal Cancer-An Umbrella Review. Cancers (Basel) 2022; 14:4391. [PMID: 36139551 PMCID: PMC9496929 DOI: 10.3390/cancers14184391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/02/2022] [Accepted: 09/06/2022] [Indexed: 12/09/2022] Open
Abstract
Introduction: The colorectal cancer prognosis depends on the stage of the neoplasm; therefore, its early detection plays an important role. The aim of the study is evaluation of the sensitivity, specificity, and clinical effectiveness of the faecal immunochemical test in the early colorectal cancer detection. Methods: The clinical analysis was based on the results of the studies included in a systematic review conducted in accordance with the Cochrane Collaboration guidelines. The following medical information sources were searched: Medline (via PubMed), Embase (via Ovid), The Cochrane Library. Results: From 241 citations, 13 studies were included in this review. All included studies had a low risk of bias. The faecal immunochemical test is highly specific in all analysed populations ranging from 85% to 97%. In most of the found studies, sensitivity is over 75%. The faecal immunochemical test screening also determines a reduction in death (10-59%) due to colorectal cancer. Conclusions: The faecal immunochemical test is an effective and cost-effective method of conducting population-wide colorectal cancer screening. It is an alternative or complementary to other screening tests, including colonoscopy.
Collapse
Affiliation(s)
- Jakub Świtalski
- Department of Health Economics and Medical Law, Faculty of Health Sciences, Medical University of Warsaw, 01-445 Warsaw, Poland
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Tomasz Tatara
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
- Department of Public Health, Faculty of Health Sciences, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Katarzyna Wnuk
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Wojciech Miazga
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Dagmara Karauda
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Adrian Matera
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Magdalena Jabłońska
- Department of Health Policy Programs, Department of Health Technology Assessment, Agency for Health Technology Assessment and Tariff System, 00-032 Warsaw, Poland
| | - Sylwia Jopek
- Department of Health Economics and Medical Law, Faculty of Health Sciences, Medical University of Warsaw, 01-445 Warsaw, Poland
| | - Urszula Religioni
- School of Public Health, Centre of Postgraduate Medical Education of Warsaw, Kleczewska 61/63, 01-826 Warsaw, Poland
| | - Mariusz Gujski
- Department of Public Health, Faculty of Health Sciences, Medical University of Warsaw, 02-091 Warsaw, Poland
| |
Collapse
|
7
|
A Comprehensive Metabolomics Analysis of Fecal Samples from Advanced Adenoma and Colorectal Cancer Patients. Metabolites 2022; 12:metabo12060550. [PMID: 35736483 PMCID: PMC9229737 DOI: 10.3390/metabo12060550] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 06/08/2022] [Accepted: 06/14/2022] [Indexed: 12/14/2022] Open
Abstract
Accurate diagnosis of colorectal cancer (CRC) still relies on invasive colonoscopy. Noninvasive methods are less sensitive in detecting the disease, particularly in the early stage. In the current work, a metabolomics analysis of fecal samples was carried out by ultra-high-performance liquid chromatography–tandem mass spectroscopy (UPLC-MS/MS). A total of 1380 metabolites were analyzed in a cohort of 120 fecal samples from patients with normal colonoscopy, advanced adenoma (AA) and CRC. Multivariate analysis revealed that metabolic profiles of CRC and AA patients were similar and could be clearly separated from control individuals. Among the 25 significant metabolites, sphingomyelins (SM), lactosylceramides (LacCer), secondary bile acids, polypeptides, formiminoglutamate, heme and cytidine-containing pyrimidines were found to be dysregulated in CRC patients. Supervised random forest (RF) and logistic regression algorithms were employed to build a CRC accurate predicted model consisting of the combination of hemoglobin (Hgb) and bilirubin E,E, lactosyl-N-palmitoyl-sphingosine, glycocholenate sulfate and STLVT with an accuracy, sensitivity and specificity of 91.67% (95% Confidence Interval (CI) 0.7753–0.9825), 0.7 and 1, respectively.
Collapse
|
8
|
Tran TN, Peeters M, Hoeck S, Van Hal G, Janssens S, De Schutter H. Optimizing the colorectal cancer screening programme using faecal immunochemical test (FIT) in Flanders, Belgium from the “interval cancer” perspective. Br J Cancer 2022; 126:1091-1099. [PMID: 35022524 PMCID: PMC8980044 DOI: 10.1038/s41416-021-01694-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/07/2021] [Accepted: 12/23/2021] [Indexed: 12/24/2022] Open
Abstract
Background Interval cancer (IC) is a critical issue in colorectal cancer (CRC) screening. We identified factors associated with ICs after faecal immunochemical test (FIT) screening and explored the impact of lowering FIT cut-off or shortening screening interval on FIT-ICs in Flanders. Methods FIT participants diagnosed with a CRC during 2013–2018 were included. Factors associated with FIT-ICs were identified using logistic regression. Distributions of FIT results among FIT-ICs were examined. Results In total, 10,122 screen-detected CRCs and 1534 FIT-ICs were included (FIT-IC proportion of 13%). FIT-ICs occurred more frequently in women (OR 1.58 [95% CI 1.41–1.76]) and ages 70–74 (OR 1.35 [1.14–1.59]). FIT-ICs were more often right-sided (OR 3.53 [2.98–4.20]), advanced stage (stage IV: OR 7.15 [5.76–8.88]), and high grade (poorly/undifferentiated: OR 2.57 [2.08–3.18]). The majority (83–92%) of FIT-ICs would still be missed if FIT cut-off was lowered from 15 to 10 µg Hb/g or screening interval was shortened from 2 to 1 year. Conclusions FIT-ICs were more common in women, older age, right-sided location, advanced stage and high grade. In Flanders, lowering FIT cut-off (to 10 µg Hb/g) or shortening screening interval (to 1 year) would have a minimal impact on FIT-ICs.
Collapse
|
9
|
Abstract
Despite strong evidence of effectiveness, colorectal cancer (CRC) screening remains underused. Currently, there are several options for CRC screening, each with its own performance characteristics and considerations for practice. This Review aims to cover current CRC screening guidelines and highlight future blood-based and imaging-based options for screening. In current practice, the leading non-invasive option is the faecal immunochemical test (FIT) based on its high specificity, good sensitivity, low cost and ease of use in mailed outreach programmes. There are currently five blood-based CRC screening tests in varying stages of evaluation, including one that is currently sold in the USA as a laboratory-developed test. There are ongoing studies on the diagnostic accuracy and longitudinal performance of blood tests and they have the potential to disrupt the CRC screening landscape. Imaging-based options, including the colon capsule, MR colonography and the CT capsule, are also being tested in active studies. As the world attempts to recover from the COVID-19 pandemic and adapts to the start of CRC screening among people at average risk starting at age 45 years, non-invasive options will become increasingly important.
Collapse
|
10
|
Analysis of Post-Colonoscopy Colorectal Cancer and Its Subtypes in a Screening Programme. Cancers (Basel) 2021; 13:cancers13205105. [PMID: 34680254 PMCID: PMC8533900 DOI: 10.3390/cancers13205105] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 10/07/2021] [Accepted: 10/09/2021] [Indexed: 11/17/2022] Open
Abstract
Using the algorithm of the World Endoscopy Organisation (WEO), we have studied retrospectively all colorectal cancers, both detected and non-detected by the Basque Country screening programme from 2009 to 2017. In the screening programme 61,335 colonoscopies were performed following a positive Faecal Immunochemical test (FIT) (≥20 µg Hb/g faeces) and the 128 cases of post-colonoscopy colorectal cancer (PCCRC) detected were analysed. Among them, 50 interval type PCCRCs were diagnosed (before the recommended surveillance), 0.8 cases per 1000 colonoscopies performed, and 78 non-interval type PCCRCs (in the surveillance carried out at the recommended time or delayed), 1.3 per 1000 colonoscopies. Among the non-interval type PCCRCs, 61 cases were detected in the surveillance carried out at the recommended time (type A) and 17 when the surveillance was delayed (type B), 1 case per 1000 colonoscopies performed and 0.28 cases per 1000 colonoscopies performed, respectively. Interval type PCCRC is less frequent than non-interval type PCCRC. In interval type PCCRCs, CRCs detected in advanced stages (stages III-IV) were significantly more frequent than those detected in early stages, compared to those of non-interval type PCCRCs (OR = 3.057; 95% CI, 1.410-6.625; p < 0.005). Non-interval type B PCCRCs are less frequent than non-interval type A PCCRCs, but the frequency of advanced stages is higher in interval type B PCCRCs.
Collapse
|
11
|
Ibáñez-Sanz G, Sanz-Pamplona R, Garcia M. Future Prospects of Colorectal Cancer Screening: Characterizing Interval Cancers. Cancers (Basel) 2021; 13:1328. [PMID: 33809520 PMCID: PMC8001713 DOI: 10.3390/cancers13061328] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/06/2021] [Accepted: 03/13/2021] [Indexed: 12/11/2022] Open
Abstract
Tumors that are not detected by screening tests are known as interval cancers and are diagnosed clinically after a negative result in the screening episode but before the next screening invitation. Clinical characteristics associated with interval colorectal cancers have been studied, but few molecular data are available that describe interval colorectal cancers. A better understanding of the clinical and biological characteristics associated with interval colorectal cancer may provide new insights into how to prevent this disease more effectively. This review aimed to summarize the current literature concerning interval colorectal cancer and its epidemiological, clinical, and molecular features.
Collapse
Affiliation(s)
- Gemma Ibáñez-Sanz
- Oncology Data Analytics Programme, Catalan Institute of Oncology, Hospitalet de Llobregat, 08907 Barcelona, Spain;
- Gastroenterology Department, Bellvitge University Hospital, Hospitalet de Llobregat, 08907 Barcelona, Spain
- Colorectal Cancer Research Group, ONCOBELL Programme, Institut d’Investigació Biomèdica de Bellvitge (IDIBELL), Hospitalet de Llobregat, 08907 Barcelona, Spain
- CIBER Epidemiology and Public Health (CIBERESP), 28029 Madrid, Spain
| | - Rebeca Sanz-Pamplona
- Oncology Data Analytics Programme, Catalan Institute of Oncology, Hospitalet de Llobregat, 08907 Barcelona, Spain;
- Colorectal Cancer Research Group, ONCOBELL Programme, Institut d’Investigació Biomèdica de Bellvitge (IDIBELL), Hospitalet de Llobregat, 08907 Barcelona, Spain
- CIBER Epidemiology and Public Health (CIBERESP), 28029 Madrid, Spain
| | - Montse Garcia
- CIBER Epidemiology and Public Health (CIBERESP), 28029 Madrid, Spain
- Cancer Screening Unit, Prevention and Control Programme, Catalan Institute of Oncology, Hospitalet de Llobregat, 08907 Barcelona, Spain
- Early Detection of Cancer Research Group, EPIBELL Programme, Institut d’Investigació Biomèdica de Bellvitge (IDIBELL), Hospitalet de Llobregat, 08907 Barcelona, Spain
| | | |
Collapse
|
12
|
pT1 Colorectal Cancer Detected in a Colorectal Cancer Mass Screening Program: Treatment and Factors Associated with Residual and Extraluminal Disease. Cancers (Basel) 2020; 12:cancers12092530. [PMID: 32899974 PMCID: PMC7565413 DOI: 10.3390/cancers12092530] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/26/2020] [Accepted: 09/04/2020] [Indexed: 12/12/2022] Open
Abstract
Simple Summary Our study has evaluated the burden of pT1 CRC (confined to submucosa) detected during the first round of a CRC screening program, the surgery related complications and the factors related to four relevant outcomes: initial endoscopic resection, surgery rescue and residual disease after endoscopic resection and, finally, extraluminal disease after surgical resection. 38% of the CRC were detected in this stage.74.9% were initially resected endoscopically and 43.8% did not require surgery. There were inhospital surgical complications in 30.7%, mainly mild with no death and complications after discharge in 16.3% of the patients Residual disease was detected in 12 (4.3%) after endoscopic resection and extraluminal disease in 18 (8.6%) patients after surgery. We have determined several variables independently associated with the four outcome variables evaluated. Abstract The aim of this study is to describe the treatment of pT1 colorectal cancer (CRC) in a mass screening program, the surgery-related complications and the factors associated with residual disease after endoscopic resection and extraluminal disease after surgery. We included in this retrospective analysis all the pT1 CRC detected in the Galician CRC screening program between May 2013 and June 2019. We determined which variables were independently associated with the outcomes of the study through a multivariable logistic regression analysis. We included 370–354 pT1 N0(X), 16 pT1N1- out of the 971 CRC detected; 277 (74.9%) were resected endoscopically and 162 (43.8%) were not referred to surgery. There were surgical complications in 30.7% and 16.3% of the patients during hospitalization and after discharge. Residual disease was detected in 12 (4.3%) after endoscopic resection and extraluminal disease in 18 (8.6%) patients after surgery. The variables independently associated with initial endoscopic resection were a pedunculated morphology (OR 33.1, 95% CI 4.3–254), a diameter ≥ 20 mm (OR 3.94, 95% CI 1.39–11.18) and a Site–Morphology–Size–Access score < 9 (OR 428, 95% CI 42–4263). The variables related with surgery rescue were a piecemeal resection (OR 4.48, 95% CI 1.48–13.6), an infiltrated/nonevaluable resection border (OR 7.44, 95% CI 2.12–26.0), a non-well-differentiated histology (OR 4.76, 95% CI 1.07–20.0), vascular infiltration (OR 8.24, 95% CI 2.72–25.0) and a Haggitt 4 infiltration of the submucosa (OR 5.68, 95% CI 2.62–12.3). Residual disease after endoscopic resection was associated with an infiltrated/nonevaluable resection border (OR 34.9, 95% CI 4.08–298), a non-well-differentiated histology (OR 6.67, 95% CI 1.05–50.0), and the vascular infiltration of the submucosa (OR 7.61, 95% CI 1.55–37.4). The variables related with extraluminal disease after surgical resection were no endoscopic resection (OR 4.34, 95% CI 1.26–14.28), a non-well-differentiated histology (OR 4.35, 95% CI 1.39–14.29) and the lymphatic infiltration of the submucosa (OR 4.8, 95% CI 1.32–17.8). In a CRC screening program, although most of pT1 CRC are candidates for endoscopic treatment, surgery is a safe procedure. We have defined some easy to evaluate variables that can be used in the decision-making process.
Collapse
|
13
|
Toes-Zoutendijk E, Kooyker AI, Dekker E, Spaander MCW, Opstal-van Winden AWJ, Ramakers C, Buskermolen M, van Vuuren AJ, Kuipers EJ, van Kemenade FJ, Velthuysen MLF, Thomeer MGJ, van Veldhuizen H, van Ballegooijen M, Nagtegaal ID, de Koning HJ, van Leerdam ME, Lansdorp-Vogelaar I, Otte J, Wiersma T, Masclee A, van Bergeijk J, Meijer G, de Graaf E, van Grevenstein W, Frasa M, Jacobs L, Stoker J, Vink G, Elferink M. Incidence of Interval Colorectal Cancer After Negative Results From First-Round Fecal Immunochemical Screening Tests, by Cutoff Value and Participant Sex and Age. Clin Gastroenterol Hepatol 2020; 18:1493-1500. [PMID: 31442598 DOI: 10.1016/j.cgh.2019.08.021] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 07/31/2019] [Accepted: 08/09/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS We evaluated the incidence of interval cancers between the first and second rounds of colorectal cancer (CRC) screening with the FOB-Gold fecal immunochemical test (FIT), and the effects of different cutoff values and patient sex and age. METHODS We collected data from participants in a population-based CRC screening program in the Netherlands who had a negative result from a first-round of FIT screening. We calculated the cumulative incidence of interval cancer after a negative result from a FIT and the sensitivity of the FIT for detection of CRC at a low (15 μg Hb/g feces) and high (47 μg Hb/g feces) cutoff value. RESULTS Among the 485,112 participants with a negative result from a FIT, 544 interval cancers were detected; 126 were in the 111,800 participants with negative results from a FIT with the low cutoff value and 418 were in the 373,312 FIT participants with negative results from a FIT with the high cutoff value. The mean age of participants tested with the low cutoff value was 72.0 years and the mean age of participants tested the high cutoff value was 66.7 years. The age-adjusted 2-year cumulative incidence of interval cancer after a negative result from a FIT were 9.5 per 10,000 persons at the low cutoff value vs 13.8 per 10,000 persons at the high cutoff value (P < .005). The age-adjusted sensitivity of the FIT for CRC were 90.5% for the low cutoff value vs 82.9% for the high cutoff (P < .0001). The FIT identified men with CRC with 87.4% sensitivity and women with CRC with 82.6% sensitivity (P < .001). CONCLUSIONS In an analysis of data from a FIT population-based screening program in the Netherlands, we found that incidence of interval CRC after a negative result from a FIT to be low. Although the sensitivity of detection of CRC decreased with a higher FIT cutoff value, it remained above 80%.
Collapse
Affiliation(s)
- Esther Toes-Zoutendijk
- Department of Public Health, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Arthur I Kooyker
- Department of Public Health, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands; Department of Gastroenterology and Hepatology, Leiden University Medical Center, Leiden, the Netherlands
| | - Evelien Dekker
- Department of Gastroenterology and Hepatology, Academic Medical Center, Academic University Medical Centers, Amsterdam, the Netherlands
| | - Manon C W Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | - Christian Ramakers
- Department of Clinical Chemistry, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Maaike Buskermolen
- Department of Public Health, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Anneke J van Vuuren
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Ernst J Kuipers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Folkert J van Kemenade
- Department of Pathology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | - Maarten G J Thomeer
- Department of Radiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Harriët van Veldhuizen
- Department of Quality Improvement, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | - Iris D Nagtegaal
- Department of Pathology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Harry J de Koning
- Department of Public Health, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Monique E van Leerdam
- Department of Gastroenterology and Hepatology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands; Department of Gastroenterology and Hepatology, Leiden University Medical Center, Leiden, the Netherlands
| | - Iris Lansdorp-Vogelaar
- Department of Public Health, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Zorzi M, Hassan C, Senore C, Capodaglio G, Turrin A, Narne E, Mussato A, Rizzato S, Chinellato E, Zamberlan S, Repici A, Rugge M. Interval colorectal cancers after negative faecal immunochemical test in a 13-year screening programme. J Med Screen 2020; 28:131-139. [PMID: 32393153 DOI: 10.1177/0969141320918613] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To assess faecal immunochemical test sensitivity for cancer in a very large population-based cohort followed up for six rounds with biennial faecal immunochemical test repetition. METHODS This study is based on interval colorectal cancers diagnosed in a cohort of subjects aged 50-69 undergoing repeated faecal immunochemical test screening (six rounds) from 2002 to 2015. Test sensitivity was calculated using both the Proportional Interval Cancer Rate and the Interval Cancer Proportion method. RESULTS Among 441,647 faecal immunochemical tests (123,347 individuals), 150 interval colorectal cancers were detected after a negative faecal immunochemical test. Interval colorectal cancer incidence rate was 1.87 per 10,000 person-years (95%CI: 1.60-2.20), and it was higher during the second interval year (rate ratio: 1.78; 95%CI: 1.28-2.47), for proximal locations (rate ratio: 3.00; 95%CI: 1.92-4.68), and among 60-71 year old subjects (rate ratio: 2.37; 95%CI: 1.61-3.50). The Proportional Interval Cancer Rate was 13.1%, with an overall faecal immunochemical test sensitivity of 86.9% (95%CI: 84.7-89.0). Sensitivity was lowest at the first round (81.5%; 95%CI: 75.6-86.2), and increased to 91.9% (95%CI: 83.9-96.5) for subsequent rounds. Applying the Interval Cancer Proportion method, sensitivity was 83.9% (95%CI: 81.3-86.2), and it was highest at the first round (89.0%; 95%CI: 85.7-91.6), ranging between 73% and 83.1% at subsequent rounds. CONCLUSIONS A faecal immunochemical test sensitivity for cancer higher than 80% resulted in a low incidence of interval colorectal cancers, representing an accurate estimate of one of the major limits of screening programmes. Due to intrinsic biases, the Proportional Interval Cancer Rate and the Interval Cancer Proportion methods generated different trends in faecal immunochemical test sensitivity by screening round.
Collapse
Affiliation(s)
- Manuel Zorzi
- Veneto Tumour Registry, Azienda Zero, Padova, Italy
| | - Cesare Hassan
- Endoscopy Unit, Nuovo Regina Margherita, Roma, Italy
| | - Carlo Senore
- Centro Prevenzione Oncologica Regione Piemonte and Azienda Ospedaliero-Universitaria S. Giovanni Battista, Torino, Italy
| | - Giulia Capodaglio
- Screening and Health Impact Assessment Unit, Azienda Zero, Padova, Italy
| | - Anna Turrin
- Screening and Health Impact Assessment Unit, Azienda Zero, Padova, Italy
| | - Elena Narne
- Screening and Health Impact Assessment Unit, Azienda Zero, Padova, Italy
| | - Alessio Mussato
- Pathology Unit, Azienda Ospedaliera di Padova, Padova, Italy
| | | | | | | | | | - Massimo Rugge
- Veneto Tumour Registry, Azienda Zero, Padova, Italy.,Department of Medicine (DIMED), Surgical Pathology & Cytopathology Unit, University of Padova, Padova, Italy
| |
Collapse
|
15
|
van de Veerdonk W, Hoeck S, Peeters M, Van Hal G, Francart J, De Brabander I. Occurrence and characteristics of faecal immunochemical screen-detected cancers vs non-screen-detected cancers: Results from a Flemish colorectal cancer screening programme. United European Gastroenterol J 2019; 8:185-194. [PMID: 32213071 DOI: 10.1177/2050640619882157] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Colorectal cancer (CRC) and its precursor lesions are detected at an early stage by CRC screening programmes, which reduce CRC-related mortality. An important quality indicator for CRC screening is the occurrence of interval CRC (IC) between screening rounds. Currently there is no guideline regarding acceptable levels of ICs in CRC screening programmes, and ICs reported in prior work vary considerably. METHODS This study describes the occurrence of screen-detected (SD) CRC and non-screen-detected CRC within the population-based CRC screening programme of Flanders, stratified by multiple variables such as sex, age, tumour location and tumour stage between October 2013 and July 2017. In addition, faecal immunochemical test (FIT) IC proportions over the sum of SD-CRCs and FIT-ICs are calculated, together with FIT sensitivity and programme sensitivity to display the effectiveness of detecting CRC by the screening programme. RESULTS Of 1,212,354 FIT participants, 4094 were diagnosed with SD-CRC, whereas 772 participants were diagnosed with CRC between FIT-screening rounds. Significant associations were shown between people not being SD for CRC and women, older individuals, right-sided tumour location and more advanced tumour stage. Furthermore, a clear distinction was shown between the right-sided and the left-sided colorectum concerning all above-mentioned variables and distributions of tumour stages. CONCLUSION The Flemish FIT-interval CRC proportion of 15.9% was within the limits of previously published results. In addition, calculations show that the effectiveness of the screening programme is dependent on tumour location, suggesting that future research should report results stratified by location.
Collapse
Affiliation(s)
- Wessel van de Veerdonk
- Faculty of Medicine and Health Sciences, Department of Social Epidemiology and Health Policy, University of Antwerp, Antwerp, Belgium
| | - Sarah Hoeck
- Faculty of Medicine and Health Sciences, Department of Social Epidemiology and Health Policy, University of Antwerp, Antwerp, Belgium.,Centre for Cancer Detection, Bruges/Antwerp, Belgium
| | - Marc Peeters
- Antwerp University Hospital, Oncology Department, Antwerp, Belgium.,Molecular Imaging, Pathology, Radiotherapy & Oncology, University of Antwerp, Belgium
| | - Guido Van Hal
- Faculty of Medicine and Health Sciences, Department of Social Epidemiology and Health Policy, University of Antwerp, Antwerp, Belgium.,Centre for Cancer Detection, Bruges/Antwerp, Belgium
| | | | | |
Collapse
|
16
|
Cobo-Cuenca AI, Laredo-Aguilera JA, Rodríguez-Borrego MA, Santacruz-Salas E, Carmona-Torres JM. Temporal Trends in Fecal Occult Blood Test: Associated Factors (2009-2017). INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E2120. [PMID: 31207996 PMCID: PMC6616453 DOI: 10.3390/ijerph16122120] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 06/09/2019] [Accepted: 06/11/2019] [Indexed: 12/13/2022]
Abstract
A cross-sectional study with 27,821 records of non-institutionalized people in Spain aged between 50-69 years old (59.94 ± 5.8 years), who participated in the European Health Survey in Spain (2009, 2014) and National Health Survey (2011/12, 2017). Fecal occult testing, the reason for performing the test, age, sex, nationality, social status, marital status, education level, body mass index (BMI), and place of residence. Overall, 54% were women, 93.9% were Spanish, 47.8% had a secondary study, and 66.4% were married. Across the years, the rate of the fecal occult blood test (FOBT) increased significantly (p < 0.001). This increase can be accounted for a letter campaign advising testing (45%, p < 0.001). FOBT was associated with more age (odds ratio-OR 1.04, 95% confidence interval-CI 1.04-1.05, p < 0.001), Spanish nationality (OR 1.91, 95% CI 1.25-2.93, p = 0.003), being married (OR 1.13, 95% CI 1.02-1.25, p = 0.025), having a higher level of education (OR 2.46, 95% CI 2.17-2.81, p < 0.001), belonging to high social classes (OR 1.35, 95% CI 1.12-1.64, p = 0.001), and BMI <25 (OR 1.72, 95% CI 1.25-2.37). Frequency of FOBT has increased in recent years. Performing FOBT is associated with age, nationality, marital status, higher education level, and social class.
Collapse
Affiliation(s)
- Ana Isabel Cobo-Cuenca
- Departamento de Enfermería, Fisioterapia y Terapia Ocupacional, Universidad de Castilla la Mancha (UCLM), 45071 Toledo, Spain.
- Grupo de Investigación Multidisciplinar en Cuidados (IMCU), UCLM. Av. Carlos III s/n., 45071 Toledo, Spain.
- Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), 14004 Córdoba, Spain.
| | - José Alberto Laredo-Aguilera
- Departamento de Enfermería, Fisioterapia y Terapia Ocupacional, Universidad de Castilla la Mancha (UCLM), 45071 Toledo, Spain.
- Grupo de Investigación Multidisciplinar en Cuidados (IMCU), UCLM. Av. Carlos III s/n., 45071 Toledo, Spain.
- Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), 14004 Córdoba, Spain.
| | - María-Aurora Rodríguez-Borrego
- Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), 14004 Córdoba, Spain.
- Departamento de Enfermería. Universidad de Córdoba (UCO), 14004 Córdoba, Spain.
| | - Esmeralda Santacruz-Salas
- Departamento de Enfermería, Fisioterapia y Terapia Ocupacional, Universidad de Castilla la Mancha (UCLM), 45071 Toledo, Spain.
- Grupo de Investigación Multidisciplinar en Cuidados (IMCU), UCLM. Av. Carlos III s/n., 45071 Toledo, Spain.
| | - Juan Manuel Carmona-Torres
- Departamento de Enfermería, Fisioterapia y Terapia Ocupacional, Universidad de Castilla la Mancha (UCLM), 45071 Toledo, Spain.
- Grupo de Investigación Multidisciplinar en Cuidados (IMCU), UCLM. Av. Carlos III s/n., 45071 Toledo, Spain.
- Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), 14004 Córdoba, Spain.
| |
Collapse
|
17
|
Schreuders EH, Grobbee EJ, Nieuwenburg SAV, Kapidzic A, van Roon AHC, van Vuuren AJ, Lansdorp-Vogelaar I, Spijker WWJ, Izelaar K, Bruno MJ, Kuipers EJ, Spaander MCW. Multiple rounds of one sample versus two sample faecal immunochemical test-based colorectal cancer screening: a population-based study. Lancet Gastroenterol Hepatol 2019; 4:622-631. [PMID: 31196734 DOI: 10.1016/s2468-1253(19)30176-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 04/14/2019] [Accepted: 04/16/2019] [Indexed: 02/08/2023]
Abstract
BACKGROUND Faecal immunochemical test (FIT)-based colorectal cancer screening requires successive rounds for maximum preventive effect. Advanced neoplasia can bleed intermittently and thus might be missed by single faecal sampling. Few studies have been done on two sample FIT (2-FIT) screening over multiple rounds. Therefore, we compared multiple rounds of one sample FIT (1-FIT) with 2-FIT screening with respect to participation, positive predictive value (PPV), diagnostic yield, and interval colorectal cancer. METHODS In this population-based study, a random selection of asymptomatic individuals aged 50-74 years in the Rotterdam-Rijnmond region, Netherlands, were invited by post for four rounds (every 2 years) of 1-FIT or 2-FIT screening. Key exclusion criteria were a history or colorectal cancer or inflammatory bowel disease, colon imaging in the previous 2 years, and life expectancy of less than 5 years. Per round, invitees received one or two FITs to sample either one or two consecutive bowel movements. OC-Sensor Micro (Eiken Chemical Co., Ltd, Japan) FITs were used by all participants, except the fourth round of screening for the 1-FIT cohort, for which participants used either an OC-Sensor or a FOB-Gold (Sentinel Diagnostics, Milan, Italy). A faecal haemoglobin cutoff concentration of 10 μg/g of faeces in at least one test was used for referral for colonoscopy. FINDINGS Between 2006 and 2015, of 10 008 invited individuals for the 1-FIT cohort, 9787 were eligible for inclusion, of whom 7310 participated at least once in four successive rounds. Of 3197 invited individuals for the 2-FIT cohort, 3131 were eligible for inclusion, and 2269 participated at least once in four successive rounds. In the 1-FIT screening cohort, 74·7% (7310 of 9787) of invitees participated at least once versus 72·5% (2269 of 3131) of invitees in the 2-FIT cohort (p=0·013). Among participants who participated at least once, the cumulative positivity rate over four rounds was 19·2% (1407 of 7310) for the 1-FIT cohort versus 28·5% (647 of 2269) for the 2-FIT cohort (p<0·0001). The cumulative PPV for advanced neoplasia was 33·0% (432 of 1308 colonoscopies) for the 1-FIT cohort versus 24·2% (147 of 607 colonoscopies) for the 2-FIT cohort (p<0·0001). The cumulative diagnostic yield of advanced neoplasia among invited individuals was 4·4% (432 of 9787) for 1-FIT versus 4·7% (147 of 3131) for 2-FIT screening (p=0·46)). FIT interval colorectal cancers were detected in eight (0·1%) of 7310 participants in the 1-FIT cohort and two (0·1%) of 2269 with 2-FIT screening (p=1·00). INTERPRETATION Four rounds of 2-FIT screening with a low faecal haemoglobin cutoff level did not result in a significant increase in diagnostic yield or a decrease in interval colorectal cancers compared with 1-FIT, despite higher colonoscopy demand. Therefore, 1-FIT colorectal cancer screening programmes should be preferred. FUNDING None.
Collapse
Affiliation(s)
- Eline H Schreuders
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Esmée J Grobbee
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Stella A V Nieuwenburg
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Atija Kapidzic
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Aafke H C van Roon
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Anneke J van Vuuren
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Iris Lansdorp-Vogelaar
- Department of Public Health, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Wolfert W J Spijker
- Regional Organization for Population Screening South-West Netherlands, Rotterdam, Netherlands
| | - Kirsten Izelaar
- Regional Organization for Population Screening South-West Netherlands, Rotterdam, Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Ernst J Kuipers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands
| | - Manon C W Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, Netherlands.
| |
Collapse
|
18
|
Wu WM, Wang Y, Jiang HR, Yang C, Li XQ, Yan B, Zhou Y, Xu WH, Lin T. Colorectal Cancer Screening Modalities in Chinese Population: Practice and Lessons in Pudong New Area of Shanghai, China. Front Oncol 2019; 9:399. [PMID: 31214488 PMCID: PMC6558000 DOI: 10.3389/fonc.2019.00399] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Accepted: 04/29/2019] [Indexed: 12/24/2022] Open
Abstract
Background: Parallel test of risk stratification and two-sample qualitative fecal immunochemical tests (FITs) are used to screen colorectal cancer (CRC) in Shanghai, China. This study was designed to identify an optimal initial screening modality based on available data. Methods: A total of 538,278 eligible residents participated in the program during the period of January 2013 to June 2017. Incident CRC was collected through program reporting system and by record linkage with the Shanghai Cancer Registry up to December 2017. Logistic regression model was applied to identify significant factors to calculate risk score for CRC. Cutoff points of risk score were determined based on Youden index and defined specificity. Sensitivity, specificity, and positive predictive values (PPVs) were computed to evaluate validity of assumed screening modalities. Results: A total of 446 CRC were screen-detected, and 777 interval or missed cases were identified through record linkage. The risk score system had an optimal cutoff point of 19 and performed better in detecting CRC and predicting long-term CRC risk than did the risk stratification. When using a cutoff point of 24, parallel test of risk score, and FIT were expected to avoid 56 interval CRCs with minimal decrease in PPV and increase in colonoscopy. However, the observed detection rates were much lower than those expected due to low compliance to colonoscopy. Conclusions: Risk score is superior to risk stratification used in the program, particularly when combined with FIT. Compliance to colonoscopy should be improved to guarantee the effectiveness of CRC screening in the population.
Collapse
Affiliation(s)
- Wei-miao Wu
- Fudan University School of Public Health, Key Lab of Health Technology Assessment, National Health Commission of the People's Republic of China (Fudan University), Shanghai, China
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
| | - Yingying Wang
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
- Center of Disease Prevention and Control in Pudong New Area of Shanghai, Shanghai, China
| | - Hui-ru Jiang
- Fudan University School of Public Health, Key Lab of Health Technology Assessment, National Health Commission of the People's Republic of China (Fudan University), Shanghai, China
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
| | - Chen Yang
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
- Center of Disease Prevention and Control in Pudong New Area of Shanghai, Shanghai, China
| | - Xiao-qiang Li
- Fudan University School of Public Health, Key Lab of Health Technology Assessment, National Health Commission of the People's Republic of China (Fudan University), Shanghai, China
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
| | - Bei Yan
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
- Center of Disease Prevention and Control in Pudong New Area of Shanghai, Shanghai, China
| | - Yi Zhou
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
- Center of Disease Prevention and Control in Pudong New Area of Shanghai, Shanghai, China
| | - Wang-hong Xu
- Fudan University School of Public Health, Key Lab of Health Technology Assessment, National Health Commission of the People's Republic of China (Fudan University), Shanghai, China
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
| | - Tao Lin
- Fudan University Pudong Institute of Preventive Medicine, Pudong New Area, Shanghai, China
- Center of Disease Prevention and Control in Pudong New Area of Shanghai, Shanghai, China
| |
Collapse
|
19
|
Wieten E, Schreuders EH, Grobbee EJ, Nieboer D, Bramer WM, Lansdorp-Vogelaar I, Bruno MJ, Kuipers EJ, Spaander MCW. Incidence of faecal occult blood test interval cancers in population-based colorectal cancer screening: a systematic review and meta-analysis. Gut 2019; 68:873-881. [PMID: 29934436 DOI: 10.1136/gutjnl-2017-315340] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2017] [Revised: 05/11/2018] [Accepted: 05/23/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Faecal immunochemical tests (FITs) are replacing guaiac faecal occult blood tests (gFOBTs) for colorectal cancer (CRC) screening. Incidence of interval colorectal cancer (iCRC) following a negative stool test result is not yet known. We aimed to compare incidence of iCRC following a negative FIT or gFOBT. DESIGN We searched Ovid Medline, Embase, Cochrane Library, Science Citation Index, PubMed and Google Scholar from inception to 12 December 2017 for citations related to CRC screening based on stool tests. We included studies on FIT or gFOBT iCRC in average-risk screening populations. Main outcome was pooled incidence rate of iCRCs per 100 000 person-years (p-y). Pooled incidence rates were obtained by fitting random-effect Poisson regression models. RESULTS We identified 7 426 records and included 29 studies. Meta-analyses comprised data of 6 987 825 subjects with a negative test result, in whom 11 932 screen-detected CRCs and 5 548 gFOBT or FIT iCRCs were documented. Median faecal haemoglobin (Hb) positivity cut-off used was 20 (range 10-200) µg Hb/g faeces in the 17 studies that provided FIT results. Pooled incidence rates of iCRC following FIT and gFOBT were 20 (95% CI 14 to 29; I2=99%) and 34 (95% CI 20 to 57; I2=99%) per 100 000 p-y, respectively. Pooled incidence rate ratio of FIT versus gFOBT iCRC was 0.58 (95% CI 0.32 to 1.07; I2=99%) and 0.36 (95% CI 0.17 to 0.75; I2=10%) in sensitivity analysis. For every FIT iCRC, 2.6 screen-detected CRCs were found (ratio 1:2.6); for gFOBT, the ratio between iCRC and screen-detected CRC was 1:1.2. Age below 60 years and the third screening round were significantly associated with a lower iCRC rate. CONCLUSION A negative gFOBT result is associated with a higher iCRC incidence than a negative FIT. This supports the use of FIT over gFOBT as CRC screening tool.
Collapse
Affiliation(s)
- Els Wieten
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Eline H Schreuders
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Esmée J Grobbee
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Daan Nieboer
- Department of Public Health, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Wichor M Bramer
- Medical Library, Erasmus University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Iris Lansdorp-Vogelaar
- Department of Public Health, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Ernst J Kuipers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Manon C W Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
20
|
Gingold-Belfer R, Leibovitzh H, Boltin D, Issa N, Tsadok Perets T, Dickman R, Niv Y. The compliance rate for the second diagnostic evaluation after a positive fecal occult blood test: A systematic review and meta-analysis. United European Gastroenterol J 2019; 7:424-448. [PMID: 31019712 DOI: 10.1177/2050640619828185] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Accepted: 01/02/2019] [Indexed: 12/12/2022] Open
Abstract
Introduction Only a minority of patients with a positive fecal occult blood test (FOBT) undergo a follow-up second diagnostic procedure, thus minimizing its contribution for colorectal cancer (CRC) prevention. We aimed to obtain a precise estimation of this problem and also assess the diagnostic yield of CRC and adenomas by colonoscopy in these patients. Methods Literature searches were conducted for "compliance" OR "adherence" AND "fecal occult blood test" OR "fecal immunohistochemical test" AND "colonoscopy." Comprehensive meta-analysis software was used. Results The search resulted in 42 studies (512,496 patients with positive FOBT), published through December 31, 2017. A funnel plot demonstrates a moderate publication bias. Compliance with any second procedure, colonoscopy, or combination of double-contrast barium enema with or without sigmoidoscopy in patients with a positive FOBT was 0.725 with 95% confidence interval (CI) 0.649-0.790 (p = 0.000), 0.804 with 95% CI 0.740-0.856 (p = 0.000) and 0.197 with 95% CI 0.096-0.361 (p = 0.000), respectively. The diagnostic yield for CRC, advanced adenoma and simple adenoma was 0.058 with 95% CI 0.050-0.068 (p = 0.000), 0.242 with 95% CI 0.188-0.306 (p = 0.000) and 0.147 with 95% CI 0.116-0.184 (p < 0.001), respectively. Discussion Compliance with diagnostic evaluation after a positive FOBT is still suboptimal. Therefore, measures to increase compliance need to be taken given the increased risk of CRC in these patients.
Collapse
Affiliation(s)
- Rachel Gingold-Belfer
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Haim Leibovitzh
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Doron Boltin
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Nidal Issa
- Department of Surgery B, Rabin Medical Center, Hasharon Hospital, Petach Tikva, Israel
| | - Tsachi Tsadok Perets
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ram Dickman
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yaron Niv
- Division of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
21
|
Colorectal cancer screening: The surgery rates they are a-changing. A nationwide study on surgical resections in Italy. Dig Liver Dis 2019; 51:304-309. [PMID: 30449608 DOI: 10.1016/j.dld.2018.10.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 09/21/2018] [Accepted: 10/17/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND Growing evidence suggests that colorectal cancer (CRC) screening based on the fecal immunochemical test (FIT) reduces CRC incidence and surgical resection rates. AIMS To compare trends in surgery for proximal and distal CRC among Italian regions at different stages of screening implementation. METHODS From the National Hospital Discharge Database we selected hospitalizations with CRC resection of residents aged 50-74 years during 2002-2014, and computed surgery rates for the 8 most populous Italian regions with/without a screening program. RESULTS In regions with screening, implemented around 2006-2007, the annual percent change (APC) of distal CRC resection was +1.7 (95% confidence interval -1.0, 4.4) during 2002-2007 and -9.1 (-10.6, -7.7) during 2007-2014. No significant change was observed in regions without screening. The APC for proximal colon resection in regions with screening was +5.8 (2.5, 9.0) during 2002-2007 and -4.1 (-5.8, -2.4) during 2007-2014, while in regions without screening surgical rates increased through the whole study period. Compared to 2002, in 2014 distal CRC resection rates were greatly reduced in regions with screening, reaching values similar to proximal CRC resection. CONCLUSION Following the implementation of screening programs surgery rates steeply decreased, confirming the deep impact of FIT-based screening on the burden of CRC.
Collapse
|
22
|
Participation in a population-based screening for colorectal cancer using the faecal immunochemical test decreases mortality in 5 years. Eur J Gastroenterol Hepatol 2019; 31:197-204. [PMID: 30543575 DOI: 10.1097/meg.0000000000001338] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND The steady increase in colorectal cancer (CRC) could be reversed through timely secondary prevention (screening) as a main strategy. The aims of this study were to determine the main features of CRC, survival rate and related factors for different types of identified CRCs in a population-based screening programme using the faecal immunochemical test (FIT). MATERIALS AND METHODS The CRCs in the susceptible population to be screened between 2009 and 2014 were identified and classified into four groups: (a) nonscreening-detected CRC (diagnosed before first screening invitation and nonparticipants), (b) screening-detected CRC, (c) interval cancer (IC) FIT (diagnosed between screening rounds after a negative FIT) and (d) IC colonoscopy (diagnosed before the colonoscopy surveillance, which is recommended after the screening colonoscopy). Patient demographics and epidemiological characteristics, tumour characteristics and survival were compared between the four groups. RESULTS 5909 individuals were diagnosed with a CRC. The median follow-up of survival was 4.6 years (range: 0-9 years). The study highlights a significant difference (P<0.0001) in the 5-year survival in the screening-detected CRC group compared with those who had nonscreening-detected CRCs (90.1 vs. 66.7%). Although ICs are not desirable events, the 5-year survival rate is significantly higher with respect to nonparticipants (P<0.0001) (76.3 vs. 60.5%), this being the group with the lowest survival rate. CONCLUSION The significantly higher 5-year survival rate of 23.4% of the participants in the screening programme suggests that incidence and mortality rates of CRC will decrease in the near future for participants in screening programmes. A high participation rate is essential to achieve health benefits, irrespective of the type of participation.
Collapse
|
23
|
Buron A, Román M, Augé JM, Macià F, Grau J, Sala M, Louro J, Martinez-Alonso M, Alvarez-Urturi C, Andreu M, Bessa X, Zaffalon D, Castells A, Pellisé M, Aldea M, Rivero L, Hernández C, Torá-Rocamora I, Castells X. Changes in FIT values below the threshold of positivity and short-term risk of advanced colorectal neoplasia: Results from a population-based cancer screening program. Eur J Cancer 2019; 107:53-59. [DOI: 10.1016/j.ejca.2018.11.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 10/28/2018] [Accepted: 11/01/2018] [Indexed: 12/24/2022]
|
24
|
Contribution of the OC Sensor ® immunoassay in comparison to the Hemoccult II ® guaiac-test in organized colorectal cancer screening. Eur J Epidemiol 2018; 34:163-172. [PMID: 30536183 DOI: 10.1007/s10654-018-0471-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Accepted: 12/04/2018] [Indexed: 02/06/2023]
Abstract
Colorectal cancer (CRC) is a major cause of cancer-related death of worldwide with high incidence and mortality rate, accessible to a screening program in France, first with guaiac- based fecal occult blood test (g-FOBT) then with fecal immunochemical tests (FIT), since 2015, because of better accuracy. The aim of our study was to compare the characteristics of screen-detected lesions in two successive CRC screening campaigns, using two different tests (Hemoccult II® and OC Sensor®) in the department of Maine-et-Loire, and to precise the performance of these tests [participation rate, detection rates (DR), positive predictive value (PPV)]. Participants, invited by CAP SANTE 49, with polyps or cancer at the colonoscopy after a positive screening test between 01/01/2013 and 31/12/2016 were included. A guaiac-based fecal occult blood test (g-FOBT) was used from January 2013 to December 2014 and a FIT was used from June 2015 to December 2016). 2575 participants, 642 in g-FOBT group and 1933 in FIT group had lesions. Participation rate was not different between tests (p = 0.104), whereas DR and PPV were statistically higher in FIT for all lesions (2.61, 95% CI [2.50-2.70] vs 0.93, 95% CI [0.90-1.00], p < 0.0001 and 64.84, 95% CI [63.10-66.60], 50.00, 95% CI [47.30-52.70], p < 0.0001 respectively). FIT detects more precancerous lesions (adenomas, p < 0.001, and advanced adenomas, p < 0.001) than g-FOBT but g-FOBT detects more serrated polyps (p = 0.025). AAs were more in right colon in FIT than g-FOBT (p = 0.035). No different participation rate was detected between FIT and g-FOBT but DR and PPV of all lesions was higher with FIT.
Collapse
|
25
|
|
26
|
Portillo I, Idigoras I, Bilbao I, Arana-Arri E, Fernández-Landa MJ, Hurtado JL, Sarasaqueta C, Bujanda L. Colorectal cancer screening program using FIT: quality of colonoscopy varies according to hospital type. Endosc Int Open 2018; 6:E1149-E1156. [PMID: 30211306 PMCID: PMC6133681 DOI: 10.1055/a-0655-1987] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Accepted: 06/05/2018] [Indexed: 12/27/2022] Open
Abstract
Background and study aims To compare the quality of colonoscopy in a population-based coordinated program of colorectal cancer screening according to type of hospital (academic or non-academic). Patients and methods Consecutive patients undergoing colonoscopy after positive FIT (≥ 20 ug Hb/g feces) between January 2009 and September 2016 were prospectively included at five academic and seven non-academic public hospitals. Screening colonoscopy quality indicators considered were adenoma detection rate, cecal intubation rate, complications and bowel preparation quality. Results A total of 48,759 patients underwent colonoscopy, 34,616 (80 %) in academic hospitals and 14,143 in non-academic hospitals. Among these cases, 19,942 (37.1 %) advanced adenomas and 2,607 (5.3 %) colorectal cancers (CRCs) were detected, representing a total of 22,549 (46.2 %) cases of advanced neoplasia. The adenoma detection rate was 64 %, 63.1 % in academic hospitals and 66.4 % in non-academic hospitals ( P < 0.001). Rates of advanced adenoma detection, cecal intubation and adequate colonic preparation were 45.8 %, 96.2 % and 88.3 %, respectively, and in all cases were lower (implying worse quality care) in academic hospitals (45.3 % vs 48.7 %; odds ratio [OR] 0.87, 95 % confidence interval [CI] 0.84 - 0.91; 95.9 % vs 97 %; OR 0.48, 95 % CI 0.38 - 0.69; and 86.4 % vs 93 %; OR 0.48, 95 % CI 0.45 - 0.5; respectively; P < 0.001 in all cases). In 13 patients, all in the academic hospital group, CRC was diagnosed after colonoscopy (0.26 cases × 1000 colonoscopies). Rates of CRC treated by endoscopy were similar in both types of hospital (30 %). The rate of severe complication was 1.2 % (602 patients), with no significant differences by hospital type: bleeding occurred in 1/147 colonoscopies and perforation in 1/329. One patient died within 30 days after screening colonoscopy. Conclusions The quality of colonoscopy was better in non-academic hospitals. The rate of detection of advanced neoplasia was higher in non-academic hospitals and correlated with the rate of post-colonoscopy CRC.
Collapse
Affiliation(s)
- Isabel Portillo
- Colorectal Cancer Screening Programme Coordination Center, Bilbao, Spain
| | - Isabel Idigoras
- Colorectal Cancer Screening Programme Coordination Center, Bilbao, Spain
| | - Isabel Bilbao
- Colorectal Cancer Screening Programme Coordination Center, Bilbao, Spain
| | | | | | - Jose Luis Hurtado
- Araba Health Organization, Osakidetza-Basque Health Service, Vitoria, Spain
| | - Cristina Sarasaqueta
- Hospital Universitario Donostia/Instituto Biodonostia, Red de Investigación en Servicios de Salud en Enfermedades Crónicas (REDISSEC), San Sebastián, Spain
| | - Luis Bujanda
- Gastroenterology Department, Instituto Biodonostia, University of Basque Country (UPV/EHU), Centro de Investigación Biomédica en Red de Enfermedades Hepaticas y Digestivas (CIBERehd), San Sebastián, Spain,Corresponding author Luis Bujanda Avda Sancho El Sabio 17-2°Dcha20010 San SebastiánSpain+34-943-007065
| | | |
Collapse
|
27
|
Burón A, Macià F, Andreu M, Pellisé M, Castells X, Grau J. Population-based colorectal cancer screening: Interval cancers and relationship with the quantitative faecal immunological for hemoglobin. Med Clin (Barc) 2018; 152:303-306. [PMID: 30146355 DOI: 10.1016/j.medcli.2018.06.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 01/19/2023]
Abstract
INTRODUCTION AND OBJECTIVE The sensitivity of colorectal cancer screening programmes determines their effectiveness and is directly related to the interval cancer (IC). This study describes the frequency and characteristics of the IC of the Programme of Barcelona, Spain, and analyses its relationship with the quantitative value of the screening test (FIT). MATERIAL AND METHODS ICs after negative FIT of the first two rounds of the Programme (2010-2013) were included, observation period until July 2017. The information source of the ICs was their notification by professionals and patients, hospital databases and CMBD (Spanish Minimum Basic Data Set). RESULTS The sensitivity of the Programme is 82%. ICs are diagnosed more in proximal and rectal colon and in advanced stages than screening cancers, and have higher FIT values than overall people with negative FIT. CONCLUSIONS The sensitivity is acceptable and comparable to that of other programmes. The quantitative value of FIT in people with negative test should be included in the personalisation strategies of screening to reduce the risk of IC.
Collapse
Affiliation(s)
- Andrea Burón
- Servicio de Epidemiología y Evaluación, Hospital del Mar, Barcelona, España; IMIM (Instituto Hospital del Mar de Investigaciones Médicas), Barcelona, España; REDISSEC (Red de Investigación en Servicios Sanitarios y Enfermedades Crónicas), Madrid, España.
| | - Francesc Macià
- Servicio de Epidemiología y Evaluación, Hospital del Mar, Barcelona, España; IMIM (Instituto Hospital del Mar de Investigaciones Médicas), Barcelona, España; REDISSEC (Red de Investigación en Servicios Sanitarios y Enfermedades Crónicas), Madrid, España
| | - Montserrat Andreu
- IMIM (Instituto Hospital del Mar de Investigaciones Médicas), Barcelona, España; Servicio de Gastroenterología, Hospital del Mar, Barcelona, España
| | - Maria Pellisé
- Servicio de Gastroenterología, Hospital Clínic, Barcelona, IDIBAPS, Barcelona, España; Centro de Investigación Biomédica en Red en Enfermedades Hepáticas y Digestivas (CIBEREHD), Madrid, España; Universidad de Barcelona, Barcelona, España
| | - Xavier Castells
- Servicio de Epidemiología y Evaluación, Hospital del Mar, Barcelona, España; IMIM (Instituto Hospital del Mar de Investigaciones Médicas), Barcelona, España; REDISSEC (Red de Investigación en Servicios Sanitarios y Enfermedades Crónicas), Madrid, España
| | - Jaume Grau
- Universidad de Barcelona, Barcelona, España; Servicio de Preventiva y Epidemiología, ICMID, Hospital Clínic, Barcelona, España
| |
Collapse
|
28
|
Interval cancers after negative immunochemical test compared to screen and non-responders' detected cancers in Slovenian colorectal cancer screening programme. Radiol Oncol 2018; 52:413-421. [PMID: 30511936 PMCID: PMC6287176 DOI: 10.2478/raon-2018-0025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 05/20/2018] [Indexed: 12/14/2022] Open
Abstract
Background We assessed the incidence and characteristics of interval cancers after faecal immunochemical occult blood test and calculated the test sensitivity in Slovenian colorectal cancer screening programme. Patients and methods The analysis included the population aged between 50 to 69 years, which was invited for screening between April 2011 and December 2012. The persons were followed-up until the next foreseen invitation, in average for 2 years. The data on interval cancers and cancers in non-responders were obtained from cancer registry. Gender, age, years of schooling, the cancer site and stage were compared among three observed groups. We used the proportional incidence method to calculate the screening test sensitivity. Results Among 502,488 persons invited for screening, 493 cancers were detected after positive screening test, 79 interval cancers after negative faecal immunochemical test and 395 in non-responders. The proportion of interval cancers was 13.8%. Among the three observed groups cancers were more frequent in men (p = 0.009) and in persons aged 60+ years (p < 0.001). Comparing screen detected and cancers in non-responders with interval cancers more interval cancers were detected in persons with 10 years of schooling or more (p = 0.029 and p = 0.001), in stage III (p = 0.027) and IV (p < 0.001), and in right hemicolon (p < 0.001). Interval cancers were more frequently in stage I than non-responders cancers (p = 0.004). Test sensitivity of faecal immunochemical test was 88.45%. Conclusions Interval cancers in Slovenian screening programme were detected in expected proportions as in similar programmes. Test sensitivity was among the highest when compared to similar programmes and was accomplished using test kit for two stool samples.
Collapse
|
29
|
Zorzi M, Capodaglio G, Rugge M. Interval Cancers in Colorectal Cancer Screening Programs. Gastroenterology 2018; 154:762-763. [PMID: 29353601 DOI: 10.1053/j.gastro.2017.09.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 09/17/2017] [Accepted: 09/22/2017] [Indexed: 12/02/2022]
Affiliation(s)
| | | | - Massimo Rugge
- Department of Medicine (DIMED), University of Padua and Veneto Tumor Registry, Veneto Region, Padua, Italy
| |
Collapse
|