1
|
Giti R, Mosallanezhad S. Effect of sintering temperature on color stability and translucency of various zirconia systems after immersion in coffee solution. PLoS One 2024; 19:e0313645. [PMID: 39541372 PMCID: PMC11563469 DOI: 10.1371/journal.pone.0313645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 10/25/2024] [Indexed: 11/16/2024] Open
Abstract
BACKGROUND AND AIM Achieving the aesthetic standards in tooth-colored restorative materials requires close attention to their color, translucency, and resistance to discoloration. This study aimed to evaluate the effect of sintering temperature on color stability and translucency in zirconia systems with low, high, and ultra-high translucencies. METHODS This experimental study was conducted on 60 zirconia disks with low, high and ultra-high translucencies (n = 20 per group), each group divided into subgroups to be sintered at either 1450°C or 1550°C (n = 10 per subgroup). Baseline color and translucency parameters were measured, the specimens were then immersed in coffee solution for 30 days, and the measurements were repeated post-immersion. Changes in color (ΔE) and translucency (ΔTP) were calculated via CIELAB formula and compared by using two-way ANOVA and Tukey's post hoc test (α = 0.05). RESULTS Results of two-way ANOVA showed that the ΔE was significantly different among the three zirconia translucencies (P<0.001), but no significant difference was found between the two sintering temperatures (P = 0.712). Additionally, the interaction between zirconia type and sintering temperature was not statistically significant for ΔE (P = 0.264). The low-translucency group showed significantly greater ΔE than the high-translucency and ultra-high-translucency groups (P<0.05), while the high- and ultra-high-translucency groups were not significantly different in this regard (P>0.05). Regarding the ΔTP, two-way ANOVA showed that the difference was not statistically significant either among the three zirconia types (P = 0.4430) or between the two sintering temperatures (P = 0.4544). Nor was the interaction between zirconia type and sintering temperature statistically significant (P = 0.5505). CONCLUSION It was concluded that sintering temperature had no effect on color and translucency changes after immersion in coffee. Whereas zirconia type significantly affected the color changes after immersion in coffee; with the higher-translucency zirconia types being significantly more color-stable than the low-translucency zirconia.
Collapse
Affiliation(s)
- Rashin Giti
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Sina Mosallanezhad
- Student Research Committee, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| |
Collapse
|
2
|
Abed MH, Kadhim AJ. Effect of speed sintering process on the microstructure, flexural strength and translucency of zirconia. Heliyon 2024; 10:e37848. [PMID: 39323859 PMCID: PMC11422002 DOI: 10.1016/j.heliyon.2024.e37848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 09/10/2024] [Accepted: 09/11/2024] [Indexed: 09/27/2024] Open
Abstract
Objectives To determine the impact of the speed sintering program on the microstructure, flexural strength and translucency of zirconia in comparison with those of the conventional sintering program. Materials and methods rectangular shape specimens (12.5 × 15.5 × 1.2 mm) were prepared from four commercial pre-sintered zirconia ceramics (KATANA HTML, KATANA STML, InCoris TZI and InCoris ZI) that were sintered with conventional and speed sintering programs according to the manufacturer's instructions. The phase composition of the sintered specimens was determined by X-ray diffraction (XRD). The grain size was evaluated using scanning electron microscopy (SEM), while the three-point flexural strength was assessed based on the ISO 6872: 2015 standard. Translucency was assessed using a spectrophotometer. The data were analyzed using independent t tests (α = 0.05) and one-way ANOVA. Results The XRD patterns were similar for all the groups, indicating that there was no phase transformation. SEM revealed that the average grain size was lower than 1 μm. The grain size, flexural strength and translucency results showed increasing trends when speed sintering is compared with the conventional one but the differences were not significant (P > 0.05). Conclusions The results of this research indicate that the speed sintering program had no significant impact on the microstructure, flexural strength and translucency of the examined zirconia, a speed-sintering program can process the ceramic material within a short time with slightly increase their flexural strength and translucency Therefore, a speed-sintering program is appropriate for zirconia (Y-TZP).
Collapse
Affiliation(s)
- Mayada Hadi Abed
- Conservative and esthetic dentistry department, College of dentistry/ University of Baghdad, Iraq
| | - Alaa Jawad Kadhim
- Conservative and esthetic dentistry department, College of dentistry/ University of Baghdad, Iraq
| |
Collapse
|
3
|
Ghanem R, Adel A, Al-Zordk W. Effect of simulated intraoral adjustment on the color and translucency of gradient multilayered monolithic zirconia. J Prosthet Dent 2024:S0022-3913(24)00597-3. [PMID: 39332992 DOI: 10.1016/j.prosdent.2024.08.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 08/29/2024] [Accepted: 08/30/2024] [Indexed: 09/29/2024]
Abstract
STATEMENT OF PROBLEM The use of multilayered monolithic zirconia ceramics is becoming popular because it simplifies the production of esthetic restorations. The effect of clinical adjustment on the optical properties of these ceramics, especially strength-gradient zirconia, remains unclear. PURPOSE The purpose of this in vitro study was to evaluate the color and translucency of gradient multilayered zirconia brands after grinding and polishing. MATERIAL AND METHODS Sixty 10×10×1-mm monolithic zirconia specimens were milled from 6 zirconia brands (Ceramill Zolid HT White, Ceramill Zolid HT Preshade, Ceramill Zolid FX Multicolor, VITA YZ XT Multicolor, IPS e.max ZirCAD Prime, and KATANA YML). The zirconia specimens were milled to include all layers of A2 preshaded multilayered zirconia blanks (A2 shade) except Ceramill Zolid HT White and Ceramill Zolid HT Preshade. Ceramill Zolid HT White specimens were milled from a white zirconia blank with subsequent shading. The color coordinates and the relative translucency parameter after glazing and after grinding and polishing were determined with a reflectance spectrophotometer, and the relative translucency parameter and contrast ratio were measured. The differences in color and translucency were calculated. The data were analyzed using 2-way ANOVA and 1-way ANOVA tests followed by the post hoc Tukey test (α=.05). RESULTS Statistically significant changes (P<.001) in the color coordinates measured before and after grinding and polishing were detected for each zirconia brand except for the KATANA YML that showed no significant difference (P=.686) in lightness. The highest color difference after grinding and polishing was detected in group KATANA YML. The 2-way ANOVA test showed a statistically significant interaction (P<.001) between the zirconia brand and the grinding and polishing regarding the relative translucency parameter. The zirconia brand had a significant impact on the relative translucency parameter before and after grinding and polishing (both P<.001). CONCLUSIONS Except for KATANA YML, the color change in multilayered zirconia after clinical adjustment with polishing was not beyond the clinically acceptable limit of the color difference. Although clinical adjustment with polishing reduced the translucency of gradient zirconia, the change in translucency was below the clinically detectable threshold value of the translucency difference.
Collapse
Affiliation(s)
- Reham Ghanem
- Graduate student, Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt
| | - Ahmed Adel
- Lecturer, Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt
| | - Walid Al-Zordk
- Assistant Professor, Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt.
| |
Collapse
|
4
|
Nakamura K, Shishido S, Inagaki R, Kanno T, Barkarmo S, Svanborg P, Örtengren U. Critical evaluations on the crystallographic properties of translucent dental zirconia ceramics stabilized with 3-6 mol% yttria. Dent Mater 2024; 40:1425-1451. [PMID: 38942711 DOI: 10.1016/j.dental.2024.06.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 06/17/2024] [Accepted: 06/18/2024] [Indexed: 06/30/2024]
Abstract
OBJECTIVES This study aimed to determine the crystalline phase composition of 3-6 mol% yttria-stabilized zirconia (3-6YSZ), specifically investigating the presence of tetragonal (t), cubic (c), and/or additional yttria-rich tetragonal (t') phase. METHODS Laboratory-fabricated specimens comprising 3-5YSZ, resembling translucent dental zirconia ceramics (TZ specimens), and a blend of 3YSZ and 8YSZ, representing a c-phase reference, were prepared. Additionally, 25 dental zirconia products stabilized with 3-6 mol% yttria were analyzed. Whole X-ray diffraction (XRD) patterns were obtained for Rietveld analysis, complemented by fine scanning in the 2θ region from 72º to 76º for qualitative phase analysis. Moreover, yttria concentrations in each specimen were determined using X-ray fluorescence (XRF) spectroscopy. RESULTS In the 2θ region from 72º to 76º, TZ and dental zirconia product specimens displayed four peaks attributed to t- and t'-phases, but the c-phase peak was absent. Rietveld analysis of the whole XRD patterns, utilizing a t-t' model, demonstrated the t-phase fraction ranging from 86 mass% in 3YSZ to 11 mass% in 6YSZ. Rietveld analysis appeared reliable, as the yttria contents calculated based on lattice parameters aligned well with those measured by XRF. This study established that dental 3-6YSZ consisted of yttria-lean t- and yttria-rich t'-phases. SIGNIFICANCE The present study enhances understanding of the crystalline structure of dental zirconia ceramics. Future crystallographic analyses of these ceramics should consider the presence of t- and t'-phases.
Collapse
Affiliation(s)
- Keisuke Nakamura
- Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980 8575, Japan; Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, SE-405 30 Gothenburg, Sweden.
| | - Shunichi Shishido
- Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980 8575, Japan
| | - Ryoichi Inagaki
- Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980 8575, Japan
| | - Taro Kanno
- Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980 8575, Japan
| | - Sargon Barkarmo
- Department of Prosthetic Dentistry/Dental Materials Science, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, SE-405 30 Gothenburg, Sweden
| | - Per Svanborg
- Department of Prosthetic Dentistry/Dental Materials Science, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, SE-405 30 Gothenburg, Sweden
| | - Ulf Örtengren
- Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, SE-405 30 Gothenburg, Sweden; Department of Material Science and Technology, Faculty of Odontology, Malmö University, SE-206 05 Malmö, Sweden
| |
Collapse
|
5
|
Tonprasong W, Inokoshi M, Tamura M, Yoshihara K, Takahashi R, Nozaki K, Wada T, Minakuchi S. Does dental material type influence bacterial adhesion under the same polishing conditions? Direct observation using a fluorescent staining technique: An in vitro study. Dent Mater J 2024; 43:485-494. [PMID: 38825451 DOI: 10.4012/dmj.2023-309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
Highly polished 3, 4, and 5 mol% yttria-stabilized zirconia and CAD/CAM composite resin samples were prepared, and the influence of surface roughness (Ra and Sa, 21 areas/group), wettability (contact angle and surface energy, 3 samples/group), and surface chemical composition (2 samples/group) on single-strain bacterial adhesion models (Porphyromonas gingivalis, Streptococcus oralis, Streptococcus sanguinis, Streptococcus gordonii, and Streptococcus mutans) were compared via fluorescent staining with graphical analysis (21 areas/group). Statistical analysis was performed using the Shapiro-Wilk test followed by one-way analysis of variance with Tukey's test or the Kruskal-Wallis test with Dunn's test (α=0.05) and linear regression. For dental zirconia with the same surface roughness, the yttria content did not significantly influence the initial bacterial adhesion. However, higher bacterial adhesion was detected for the composite resin owing to its high C, O, and Si contents. There was no correlation between surface energy and bacterial adhesion for any bacterial strain (p<0.005).
Collapse
Affiliation(s)
- Watcharapong Tonprasong
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Muneaki Tamura
- Department of Microbiology and Immunology, Nihon University School of Dentistry
| | - Kumiko Yoshihara
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST)
- Department of Pathology and Experimental Medicine, Okayama University, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
| | - Rena Takahashi
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kosuke Nozaki
- Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Takahiro Wada
- Department of Advanced Biomaterials, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
6
|
Chai H, Russ J, Vardhaman S, Lim C, Zhang Y. A Bilayer Method for Measuring Toughness and Strength of Dental Ceramics. J Dent Res 2024; 103:419-426. [PMID: 38410925 PMCID: PMC10966932 DOI: 10.1177/00220345231225445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024] Open
Abstract
The ever-increasing usage of ceramic materials in restorative dentistry necessitates a simple and effective method to evaluate flexural strength σF and fracture toughness KC. We propose a novel method to determine these quantities using a bilayer specimen composed of a brittle plate adhesively bonded onto a transparent polycarbonate substrate. When this bilayer structure is placed under spherical indentation, tunneling radial cracks initiate and propagate in the lower surface of the brittle layer. The failure analysis is based on previous theoretical relationships, which correlate σF with the indentation force P and layer thickness d, and KC with P and mean length of radial cracks. This work examines the accuracy and limitations of this approach using a wide range of contemporary dental ceramic materials. The effect of layer thickness, indenter radius, load level, and length and number of radial cracks are carefully examined. The accuracy of the predicted σF and KC is similar to those obtained with other concurrent test methods, such as biaxial flexure and 3-point bending (σF), and bending specimens with crack-initiation flaws (KC). The benefits of the present approach include treatment for small and thin plates, elimination of the need to introduce a precrack, and avoidance of dealing with local material nonlinearity effects for the KC measurements. Finally, the bilayer configuration resembles occlusal loading of a ceramic restoration (brittle layer) bonded to a posterior tooth (compliant substrate).
Collapse
Affiliation(s)
- H. Chai
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| | - J. Russ
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - S. Vardhaman
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
- College of Dental Medicine, Columbia University, New York, NY, USA
| | - C.H. Lim
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| | - Y. Zhang
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
7
|
Katada H, Inokoshi M, Kamijo S, Liu H, Xu K, Kawashita M, Yokoi T, Shimabukuro M, Minakuchi S. Effects of multiple firings on the translucency, crystalline phase, and mechanical strength of highly translucent zirconia. Dent Mater J 2024; 43:294-302. [PMID: 38432949 DOI: 10.4012/dmj.2023-255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024]
Abstract
This study aimed to clarify the effects of multiple firings on the translucency, crystal structure, and mechanical strength of highly translucent zirconia. Four types of highly translucent zirconia (LAVA Esthetic, LAVA Plus, KATANA Zirconia STML, and KATANA Zirconia HTML) were fired three times at three different temperatures, and the translucency, crystal structure, and flexural strength were evaluated before and after firing. The translucency was statistically compared using repeated-measures analysis of variance; the zirconia phase composition was assessed using X-ray diffraction followed by Rietveld analysis; and the biaxial flexural strength was assessed using Weibull analysis. The translucency of LAVA Esthetic and KATANA Zirconia HTML decreased significantly after firing, and the crystal composition of LAVA Plus and KATANA Zirconia HTML changed after multiple firings, whereas multiple firings did not affect the biaxial flexural strength of any samples. Thus, multiple firings may affect the optical properties of highly translucent zirconia.
Collapse
Affiliation(s)
- Haruko Katada
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Singo Kamijo
- Basic Oral Health Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kaiqi Xu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masakazu Kawashita
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Taishi Yokoi
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Masaya Shimabukuro
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
8
|
Sun H, Tabrizian P, Qambrani A, Jargalsaikhan U, Sui T, Ireland T, Su B. Bio-inspired nacre-like zirconia/PMMA composites for chairside CAD/CAM dental restorations. Dent Mater 2024; 40:307-317. [PMID: 38040580 DOI: 10.1016/j.dental.2023.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/14/2023] [Accepted: 11/23/2023] [Indexed: 12/03/2023]
Abstract
OBJECTIVES To introduce a versatile fabrication process to fabricate zirconia/PMMA composites for chairside CAD/CAM dental restorations. These zirconia composites have nacre-like lamellar microstructures, competent and tooth-matched mechanical properties, as well as crack resistance behaviours. METHODS Bi-directional freeze casting was used to fabricate ceramic green bodies with highly aligned lamellar structure. Pressure was then applied to control the ceramic volume fraction. PMMA was infiltrated into the ceramic scaffold. Mechanical tests including 3-point bending, Vickers hardness, and fracture toughness were performed on the composites. The machinability of the composites was also characterised. RESULTS Two types of nacre-like zirconia/PMMA composites, i.e., 3Y-YZP/PMMA and 5Y-PSZ/PMMA composites were fabricated. The microstructure created was similar to the 'brick and mortar' structure of nacre. Excellent flexural strength (up to 400 MPa and 290 MPa for 3Y-TZP/PMMA and 5Y-PSZ/PMMA composite, respectively), tuneable hardness and elastic modulus within the range similar to enamel, along with improved crack-resistance behaviour were demonstrated on both zirconia composites. In addition, both zirconia/PMMA composites showed acceptable machinability, being easy to mill, as would be required to produce a dental crown. SIGNIFICANCE Nacre-like zirconia/PMMA composites therefore exhibit the potential for use in the production of chairside CAD/CAM dental restorations.
Collapse
Affiliation(s)
- Huijun Sun
- Biomaterials Engineering Group, Bristol Dental School, University of Bristol, UK
| | - Parinaz Tabrizian
- Biomaterials Engineering Group, Bristol Dental School, University of Bristol, UK
| | - Aqsa Qambrani
- Department of Mechanical Engineering Sciences, University of Surrey, UK
| | | | - Tan Sui
- Department of Mechanical Engineering Sciences, University of Surrey, UK
| | - Tony Ireland
- Biomaterials Engineering Group, Bristol Dental School, University of Bristol, UK
| | - Bo Su
- Biomaterials Engineering Group, Bristol Dental School, University of Bristol, UK.
| |
Collapse
|
9
|
Su G, Zhang Y, Jin C, Zhang Q, Lu J, Liu Z, Wang Q, Zhang X, Ma J. 3D printed zirconia used as dental materials: a critical review. J Biol Eng 2023; 17:78. [PMID: 38129905 PMCID: PMC10740276 DOI: 10.1186/s13036-023-00396-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023] Open
Abstract
In view of its high mechanical performance, outstanding aesthetic qualities, and biological stability, zirconia has been widely used in the fields of dentistry. Due to its potential to produce suitable advanced configurations and structures for a number of medical applications, especially personalized created devices, ceramic additive manufacturing (AM) has been attracting a great deal of attention in recent years. AM zirconia hews out infinite possibilities that are otherwise barely possible with traditional processes thanks to its freedom and efficiency. In the review, AM zirconia's physical and adhesive characteristics, accuracy, biocompatibility, as well as their clinical applications have been reviewed. Here, we highlight the accuracy and biocompatibility of 3D printed zirconia. Also, current obstacles and a forecast of AM zirconia for its development and improvement have been covered. In summary, this review offers a description of the basic characteristics of AM zirconia materials intended for oral medicine. Furthermore, it provides a generally novel and fundamental basis for the utilization of 3D printed zirconia in dentistry.
Collapse
Affiliation(s)
- Guanyu Su
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Yushi Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Chunyu Jin
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Qiyue Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Jiarui Lu
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Zengqian Liu
- Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China
- School of Materials Science and Engineering, University of Science and Technology of China, Hefei, 230026, China
| | - Qiang Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Xue Zhang
- Department of Orthodontics, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China.
| | - Jia Ma
- Department of Orthodontics, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China.
| |
Collapse
|
10
|
Liu H, Inokoshi M, Xu K, Tonprasong W, Minakuchi S, Van Meerbeek B, Vleugels J, Zhang F. Does speed-sintering affect the optical and mechanical properties of yttria-stabilized zirconia? A systematic review and meta-analysis of in-vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2023; 59:312-328. [PMID: 37705876 PMCID: PMC10495607 DOI: 10.1016/j.jdsr.2023.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/02/2023] [Accepted: 08/22/2023] [Indexed: 09/15/2023] Open
Abstract
Zirconia restorations are increasingly popular in dental treatment. Yttria-stabilized zirconia (YSZ) needs to be sintered for clinical applications and novel speed-sintering protocols are being developed for chairside treatments. Whether the properties of speed-sintered YSZ meet clinical requirements, however, remains unclear. Therefore, we conducted a systematic review and meta-analysis on the influence of speed-sintering on the optical and mechanical properties of dental YSZ according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. A literature search was conducted using PubMed, Embase, and Web of Science databases for relevant articles published between January 1, 2010 and February 28, 2022 in English, Chinese, or Japanese. After full-text evaluation and quality assessment, 26 articles were selected. Meta-analysis revealed that speed-sintering does not significantly affect the CIEDE2000-based translucency parameter, contrast ratio, three-point flexural strength, biaxial flexural strength, or fracture toughness of YSZ (p < 0.01) compared to conventional sintering. However, the CIELab-based translucency parameter of conventionally sintered YSZ is higher than that of speed-sintered YSZ. The descriptive analysis indicated that speed-sintering does not affect the hardness of YSZ compared to that of conventionally sintered YSZ. The results indicate that speed-sintering is suitable for preparing YSZ for dental restorations.
Collapse
Affiliation(s)
- Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Kaiqi Xu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Watcharapong Tonprasong
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 blok a, B-3000 Leuven, Belgium
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium
| | - Fei Zhang
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 blok a, B-3000 Leuven, Belgium
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium
| |
Collapse
|
11
|
Alghazzawi TF. A Comparison of Failure Loads for Polycrystalline Zirconia Ceramics with Varying Amounts of Yttria, Glass-Ceramics and Polymers in Two Different Test Conditions. Polymers (Basel) 2023; 15:4506. [PMID: 38231917 PMCID: PMC10708478 DOI: 10.3390/polym15234506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/14/2023] [Accepted: 11/21/2023] [Indexed: 01/19/2024] Open
Abstract
It is unclear how zirconia dental crowns with different yttria compositions will perform clinically, and how they will compare with crowns made of glass-ceramics and polymers. The present objective was to determine failure loads of crowns and discs made of glass ceramics or polymers as compared to yttria-partially stabilized zirconia (Y-PSZ) crowns and discs with varying yttria concentrations. Crowns of zirconia (Cercon XT, Katana UTML, BruxZir Anterior), glass ceramic (Celtra press, IPS e.max press, Lisi press), and polymeric materials (Trilor, Juvora, Pekkton) were fabricated and cemented to epoxy abutments. The total number of specimens was 135 for crowns and 135 for discs (n = 15 specimens per material type and design). A universal testing machine was used to perform compressive loading of crowns/discs to failure with a steel piston along the longitudinal axis of the abutments. Energy dispersive spectroscopy (EDS) was used to identify the yttria concentration for each zirconia brand. The data were analyzed using generalized linear models and regression analyses. The results revealed significant differences (p < 0.05) in mean failure loads for different crown materials: Trilor (6811 ± 960 N) > Juvora (5215 ± 151 N) > Cercon (4260 ± 520 N) = BruxZir (4186 ± 269 N) = e.max (3981 ± 384 N) > Katana (3195 ± 350 N) = Lisi (3173 ± 234 N) = Pekkton (3105 ± 398 N) > Celtra (2696 ± 393 N). The general linear model revealed significant differences (p < 0.05) in mean failure loads when comparing the different materials for the discs, i.e., Trilor (5456 ± 1748 N) > Juvora (4274 ± 869 N) > Pekkton (3771 ± 294 N) > Katana (2859 ± 527 N) > Cercon (2319 ± 342 N) = BuxZir (2250 ± 515 N) = e.max (2303 ± 721 N) = Lisi (2333 ± 535 N) > Celtra (1965 ± 659 N). EDS showed that the zirconia materials contained yttria at different concentrations (BruxZir = 5Y-PSZ, Cercon = 4Y-PSZ, Katana = 3Y-PSZ). The yttria concentration had a significant effect on the failure load of the Katana (3Y-PSZ) crowns, which revealed lower failure loads than the Cercon (4Y-PSZ) and BruxZir (5Y-PSZ) crowns, whose failure loads were comparable or higher than e.max glass ceramic. The failure load of the trilayer disc specimens did not correlate with the failure load of the respective crown specimens for the zirconia, glass-ceramic and polymeric materials.
Collapse
Affiliation(s)
- Tariq F. Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madinah 42353, Saudi Arabia;
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
12
|
Lubauer J, Schuenemann FH, Belli R, Lohbauer U. Speed-sintering and the mechanical properties of 3-5 mol% Y 2O 3-stabilized zirconias. Odontology 2023; 111:883-890. [PMID: 36859729 PMCID: PMC10492746 DOI: 10.1007/s10266-023-00796-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 02/15/2023] [Indexed: 03/03/2023]
Abstract
Ever faster workflows for the fabrication of all-ceramic restorations are of high economic interest. For that purpose, sintering protocols have been optimized for use in modern sintering furnaces, the so-called speed-sintering. However, conventional furnaces are still the most widely used equipment to sinter zirconia restorations. In this in-vitro study, we evaluated the feasibility of a speed-sintering protocol using a conventional sintering furnace to sinter different dental zirconias (stabilized with 3 mol% up to 5.4 mol% Y2O3) in comparison to a conventional sintering program. The properties evaluated were Young's modulus, Poisson's ratio, density, biaxial flexural strength, and fracture toughness. We show here that despite differences being dependent on material, the physical and mechanical properties of speed-sintered zirconia are comparable to those obtained by the conventional sintering.
Collapse
Affiliation(s)
- Julia Lubauer
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| | - Fernanda Haverroth Schuenemann
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| | - Renan Belli
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany.
| | - Ulrich Lohbauer
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| |
Collapse
|
13
|
Cho MH, Seol HJ. Effect of High-Speed Sintering on the Optical Properties, Microstructure, and Phase Distribution of Multilayered Zirconia Stabilized with 5 mol% Yttria. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5570. [PMID: 37629861 PMCID: PMC10456241 DOI: 10.3390/ma16165570] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 07/28/2023] [Accepted: 08/03/2023] [Indexed: 08/27/2023]
Abstract
As dental 5 mol% yttria-stabilized (5Y-) zirconia demand high esthetics, it is necessary to clarify how the optical properties are affected by high-speed sintering, which is not yet fully understood. Our study aimed to investigate the effect of high-speed sintering on the translucency and opalescence parameters (TP and OP, respectively), as well as their related microstructure and phase distribution, using two types of multilayered 5Y-zirconia. Multilayered 5Y-zirconia (Cercon xt ML, Lava Esthetic) were cut layer-by-layer, followed by conventional and high-speed sintering. The TP and OP values were subsequently obtained using a spectrophotometer, and field emission scanning electron microscopy images were used to analyze the average grain size. The phase fractions were analyzed using X-ray diffraction. Regardless of the zirconia type, the TP was slightly lowered by high-speed sintering in all the layers except the dentin layer (DL) for Lava Esthetic (p < 0.05). The OP decreased by high-speed sintering in the DL for Cercon xt ML and in all the layers for Lava Esthetic (p < 0.05). The decrease in translucency after high-speed sintering was attributed to a decrease in the yttria-rich t'-phase with low tetragonality, along with an increase in the yttria-lean t-phase with high tetragonality.
Collapse
Affiliation(s)
- Mi-Hyang Cho
- Department of Dental Lab, Wonkwang Health Science University, Iksan-si 54538, Republic of Korea;
| | - Hyo-Joung Seol
- Department of Dental Materials, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan-si 50612, Republic of Korea
| |
Collapse
|
14
|
Wille S, Möller R, Kern M. Influence of shading on zirconia's phase transformation and flexural strength after artificial aging. Dent Mater 2023; 39:702. [PMID: 37385942 DOI: 10.1016/j.dental.2023.06.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 05/17/2023] [Accepted: 06/14/2023] [Indexed: 07/01/2023]
Abstract
OBJECTIVES The aim of this study was to determine the phase transformation and the influence of aging on the flexural strength of different colored zirconia. The effect of hydrothermal aging in an autoclave was compared with the effect of mechanical stress by simulating chewing. METHODS High-strength zirconia (3Y-TZP) was investigated in three different colors: uncolored, A3, and D3. Disc-shaped specimens (N = 3) were analyzed by X-ray diffraction (XRD), and flexural strength was determined on bar-shaped specimens (N = 15) in a 4-point bending test before and after performing two different aging protocols: aging in an autoclave (134 °C, 70 h) and aging in a chewing simulator (5 kg load, 1.2 million cycles). During autoclave aging, the fraction of monoclinic phase on the surface was determined every 5 h. Once this exceeded 25 vol%, aging of the bar specimens was stopped. RESULTS While in the unstained group the mean value of the proportion of monoclinic phase already exceeded 25 vol% after 30 h in the autoclave, this was the case in both stained groups only after 70 h. No measurable phase transformation could be detected after chewing simulation. Only color A3 showed a statistically significant (p ≤ 0.05) decrease in flexural strength after aging in the chewing simulator. SIGNIFICANCE The colored zirconia showed a higher resistance to phase transformation through hydrothermal aging. The metal oxides in the staining solutions are assumed to hinder the phase transformation in the zirconia. Therefore, the significant reduction in the stained zirconia after chewing simulation is particularly interesting.
Collapse
Affiliation(s)
- Sebastian Wille
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Rüdiger Möller
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| |
Collapse
|
15
|
Inokoshi M, Liu H, Yoshihara K, Yamamoto M, Tonprasong W, Benino Y, Minakuchi S, Vleugels J, Van Meerbeek B, Zhang F. Layer characteristics in strength-gradient multilayered yttria-stabilized zirconia. Dent Mater 2023; 39:430-441. [PMID: 36914432 DOI: 10.1016/j.dental.2023.03.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 02/15/2023] [Accepted: 03/03/2023] [Indexed: 03/16/2023]
Abstract
OBJECTIVES To investigate crystallography, translucency, phase content, microstructure and flexural strength of two commercial strength-gradient multilayered dental zirconia grades. METHODS Two zirconia grades, i.e., KATANA Zirconia YML (Kuraray Noritake; referred to as "YML"; composed of four layers: enamel, body 1-3) and IPS e.max ZirCAD Prime (Ivoclar Vivadent; referred to as "Prime"; composed of three layers: enamel, transition, body) were investigated. Fully sintered square-shaped zirconia specimens from each layer were prepared. Microstructure, chemical composition, translucency parameter and zirconia-phase composition of each layer were characterized. Four-point and biaxial flexural strength of each layer was measured using fully sintered bar- and square-shaped specimens. Square-shaped samples were used to measure strength across the layers. RESULTS For both multilayer zirconia grades, the 'enamel' layer contains a higher amount of c-ZrO2, which resulted in higher translucency but lower flexural strength than the 'body' layers. The characteristic 4-point flexural strength of the YML 'body 2' (923 MPa) and 'body 3' (911 MPa) layers, and of the Prime 'body' (989 MPa) layer were comparable and higher than for the YML 'enamel' (634 MPa), Prime 'transition' (693 MPa) and 'enamel' (535 MPa) layers. The biaxial strength of specimens sectioned across the layers was in-between that of the 'enamel' and 'body' layers for both YML and Prime, implying the interfaces did not form a weak link. SIGNIFICANCE The difference in yttria content affects the phase composition and mechanical properties of each layer of the multi-layer zirconia. The strength-gradient approach allowed to integrate monoliths with irreconcilable properties.
Collapse
Affiliation(s)
- Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan.
| | - Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Kumiko Yoshihara
- National Institute of Advanced Industrial Science and Technology (AIST), Health Research Institute, 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan; Okayama University, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Department of Pathology & Experimental Medicine, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Mao Yamamoto
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Watcharapong Tonprasong
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Yasuhiko Benino
- Okayama University, Graduate School of Environmental and Life Science, 1 Chome-1-1 Tsushimanaka, Kita-ku, Okayama 700-8530, Japan
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7, Blok a - Box 7001, BE-3000 Leuven, Belgium
| | - Fei Zhang
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7, Blok a - Box 7001, BE-3000 Leuven, Belgium
| |
Collapse
|
16
|
Jung JM, Kim GN, Koh YH, Kim HE. Manufacturing and Characterization of Dental Crowns Made of 5-mol% Yttria Stabilized Zirconia by Digital Light Processing. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1447. [PMID: 36837076 PMCID: PMC9963883 DOI: 10.3390/ma16041447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
We herein report manufacturing of dental crowns made of 5-mol% yttria partially stabilized zirconia (5Y-PSZ) with desired mechanical properties, optical translucency and dimensional accuracy using digital light processing (DLP). To this end, all processing parameters were carefully controlled and optimized. First, 5Y-PSZ particles with a bimodal distribution were prepared via calcination of as-received granules and subsequent ball-milling and then used to formulate 5Y-PSZ suspensions with a high solid loading of 50 vol% required for high densification after sintering. Dispersant content was also optimized. To provide high dimensional accuracy, initial dimensions of dental crowns for 3D printing were precisely determined by considering increase and decrease in dimensions during photopolymerization and sintering, respectively. Photopolymerization time was also optimized for a given layer thickness of 50 μm to ensure good bonding between layers. A multi-step debinding schedule with a slow heating rate was employed to avoid formation of any defects. After sintering at 1500 °C for 2 h, 5Y-PSZ could be almost fully densified without noticeable defects within layers and at interfaces between layers. They had high relative densities (99.03 ± 0.39%) with a high cubic phase content (59.1%). These characteristics allowed for achievement of reasonably high mechanical properties (flexural strength = 625.4 ± 75.5 MPa and Weibull modulus = 7.9) and % transmittance (31.4 ± 0.7%). In addition, 5Y-PSZ dental crowns showed excellent dimensional accuracy (root mean square (RMS) for marginal discrepancy = 44.4 ± 10.8 μm and RMS for internal gap = 22.8 ± 1.6 μm) evaluated by the 3D scanning technique.
Collapse
Affiliation(s)
- Jae-Min Jung
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Gyu-Nam Kim
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Young-Hag Koh
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Hyoun-Ee Kim
- Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Republic of Korea
| |
Collapse
|
17
|
Yan M, Ding SJ, Lin CW, Wei CL, Huang YW, Yang CC. Aging resistance of highly translucent zirconia ceramics with rapid sintering. J Oral Sci 2023; 65:15-19. [PMID: 36403959 DOI: 10.2334/josnusd.22-0264] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE Rapid sintering technology has become one of the most direct methods for shortening the manufacturing time of zirconia restorations. This study aimed to explore the aging resistance of rapid-sintered 5 mol% yttria-partially-stabilized zirconia (5Y-PSZ). METHODS Specimens were made from two types of 5Y-PSZ material and subjected to rapid sintering (RS) and conventional sintering (CS). After in vitro aging for 5 h, morphology observation, grain size measurement, and phase composition analysis were performed. The mechanical properties were evaluated by biaxial, three-point flexural tests, and the Vickers microhardness test. Results were analyzed by 3-way ANOVA. RESULTS Both the RS group and the CS group had a dense microstructure. The tested zirconia ceramics had different grain sizes, which were affected by the interaction between the sintering method and aging. Both groups revealed the same characteristic peaks of the cubic phase after aging. Regardless of the sintering method used, there was no significant difference in the mechanical properties of the tested zirconia before and after aging. CONCLUSION The rapid-sintered 5Y-PSZ materials had a microstructure, phase composition and mechanical properties similar to those of conventional sintered materials. The characteristics of the materials prepared using the two sintering methods did not change significantly after aging.
Collapse
Affiliation(s)
- Min Yan
- Institute of Oral Sciences, Chung Shan Medical University.,Department of Dentistry, Chung Shan Medical University Hospital, Chung Shan Medical University
| | - Shinn-Jyh Ding
- Institute of Oral Sciences, Chung Shan Medical University.,Department of Dentistry, Chung Shan Medical University Hospital, Chung Shan Medical University
| | - Cheng-Wei Lin
- Department of Dental Technology and Materials Science, Central Taiwan University of Science and Technology
| | - Cian-Li Wei
- Institute of Oral Sciences, Chung Shan Medical University
| | - Yi-Wen Huang
- Institute of Oral Sciences, Chung Shan Medical University
| | - Chun-Chuan Yang
- Department of Dental Technology, Shu-Zen Junior College of Medicine and Management
| |
Collapse
|
18
|
Nonaka K, Teramae M, Pezzotti G. Effect of Ga 2O 3 Dopant on High Speed Sintered 5 mol% Y 2O 3 Stabilized Dental Zirconia. MATERIALS (BASEL, SWITZERLAND) 2023; 16:714. [PMID: 36676451 PMCID: PMC9866617 DOI: 10.3390/ma16020714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 06/17/2023]
Abstract
The high-speed sintering of zirconia has become essential for ceramic dental prosthesis treatment in a single visit. Previous studies have shown that 5 mol% yttria-stabilized zirconia (5Y zirconia), with the exception of some types, loses strength and translucency with high-speed sintering. In this study, 0.15-0.92 wt% Ga2O3, which is expected to promote the sintering of zirconia, was added to improve the properties of 5Y zirconia high-speed sintered bodies, and the effect of its addition was evaluated. The specimens were characterized by density and translucency measurements, a three-point bending test, X-ray diffraction (XRD), scanning electron microscopy (SEM), and shrinkage measurement. The addition of Ga2O3 improved both translucency and flexural strength of 5Y zirconia high-speed sintered bodies. XRD and SEM observations revealed that this improvement in properties was due to the change in the crystal phase composition and the decrease in the amount and size of pores due to the addition of Ga2O3. Shrinkage measurements also revealed that the addition of Ga2O3 changed the sintering behavior of 5Y zirconia, suggesting that this change led to a reduction in porosity. From the above results, it was concluded that Ga2O3 addition is effective in improving the properties of 5Y zirconia high-speed sintered bodies.
Collapse
Affiliation(s)
- Kazumichi Nonaka
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto 605-0983, Japan
| | - Mitsuji Teramae
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto 605-0983, Japan
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
| |
Collapse
|
19
|
Lee WF, Takahashi H, Iwasaki N, Peng PW. Effect of thickness of externally characterized stains on optical properties of high-translucency zirconia. Clin Oral Investig 2023; 27:165-171. [PMID: 36125622 DOI: 10.1007/s00784-022-04704-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 08/29/2022] [Indexed: 01/28/2023]
Abstract
OBJECTIVES There is insufficient information about the effects of the thickness of externally characterized stains or glazes on CIELAB color parameters and the translucency parameter (TP) of 5 mol% yttria partially stabilized zirconia (5Y-PSZ). The present study evaluated the effect of a thickness reduction of the externally characterized or glazed layer on its CIE2000 color parameters and TP00 of 5Y-PSZ. MATERIALS AND METHODS Twenty-eight specimens were sectioned from 5Y-PSZ blanks. Three brands of powdered stains (namely VI, SH, and IV) and a glaze (GL) were used to extrinsically stain the specimen surfaces (n = 7 per group). After measuring the final thickness and color, specimens of each group were carefully ground and finally polished. The reduced thickness was carefully controlled in decrements of 0.02 mm on the characterized stains or glazed layers at each reduction cycle until the surface of the un-stained zirconia was exposed. The CIELAB color parameters of specimens were measured using a spectrophotometer. Subsequently, differences in lightness (∆L'), chroma (∆C'), and hue (∆H'), and TP00 values and color differences (ΔE00) were calculated using the CIEDE2000 formula to determine differences between the specimen and the un-stained zirconia at each reduction cycle. A paired-samples t-test, two-way mixed-design analysis of variance, and Pearson correlation coefficient were used to analyze the data (α = 0.05). RESULTS There were no significant differences in lightness, chroma, hue, or TP00 values before or after glazing or after each reduction cycle of the glazed layer. Mean ΔE00 values ranged between 20.94 and 33.55 after applying the externally characterized stains. With a decreased thickness of the characterized stain layer, there were observed that significant decreases in ∆L', ∆H', ∆C', and ΔE00, and significant increases in TP00. CONCLUSIONS Increasing the thickness of externally characterized stains decreased the lightness and caused the alternation of chroma and hue, whereas these phenomena were not observed in the glazed group. There was a slight change of CIE2000 color parameters and TP00 when the thickness of the characterized layer exceeded 0.06 mm. CLINICAL RELEVANCE The application and thickness of externally characterized stains can sensitively affect CIE2000 color parameters and translucency of 5Y-PSZ.
Collapse
Affiliation(s)
- Wei-Fang Lee
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan
| | - Hidekazu Takahashi
- School of Oral Health Engineering, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan
| | - Naohiko Iwasaki
- School of Oral Health Engineering, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan
| | - Pei-Wen Peng
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan.
| |
Collapse
|
20
|
Nonaka K, Teramae M, Pezzotti G. Evaluation of the Effect of High-Speed Sintering and Specimen Thickness on the Properties of 5 mol% Yttria-Stabilized Dental Zirconia Sintered Bodies. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5685. [PMID: 36013827 PMCID: PMC9412651 DOI: 10.3390/ma15165685] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/08/2022] [Accepted: 08/13/2022] [Indexed: 06/15/2023]
Abstract
High-speed sintering of zirconia has become essential to single-visit dental prosthetic treatments. This important prosthetic dentistry technique demands a translucent material tougher than porcelain. Previous studies on high-speed sintered zirconia did not take heat and material thickness into consideration. We evaluated pre-sintered specimen thickness and the effect of high-speed sintering on the properties of 5 mol% Y2O3-stabilized zirconia (5Y zirconia). High-speed sintered bodies of 5Y zirconia were evaluated by density measurements, translucency measurements, three-point flexural and fracture toughness tests, X-ray diffraction (XRD), and scanning electron microscopy (SEM). High-speed sintering reduced the translucency and mechanical properties of 5Y zirconia. XRD and SEM observation results clarified that these reductions were due to the change in crystal phase composition and to the increase in residual pores, respectively, both resulting from high-speed sintering. Moreover, in high-speed sintering, as the thickness of the specimen increased, the number and size of internal pores increased, and the translucency and strength decreased. The threshold value for avoiding a reduction in translucency and mechanical properties was found to lie at ~4.4 mm. From the above results, it was concluded that 5Y zirconia is not suitable for high-speed sintering applications.
Collapse
Affiliation(s)
- Kazumichi Nonaka
- Department of Research and Development, SHOFU INC, Higashiyama-ku, Kyoto 605-0983, Japan
| | - Mitsuji Teramae
- Department of Research and Development, SHOFU INC, Higashiyama-ku, Kyoto 605-0983, Japan
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
| |
Collapse
|
21
|
Influence of high-speed sintering protocols on translucency, mechanical properties, microstructure, crystallography, and low-temperature degradation of highly translucent zirconia. Dent Mater 2021; 38:451-468. [PMID: 34961644 DOI: 10.1016/j.dental.2021.12.028] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 12/15/2021] [Accepted: 12/15/2021] [Indexed: 01/24/2023]
Abstract
OBJECTIVES Impacts of high-speed sintering on the optical and mechanical properties, microstructure, crystallography, and low-temperature degradation of commercial yttria-partially stabilized zirconia (Y-PSZ) were investigated. METHODS Five commercial Y-PSZ products (KATANA HT, KATANA STML, KATANA UTML, Zpex 4, and Zpex Smile) were investigated. Specimens were sintered following speed-sintering (~90 min) and conventional-sintering protocols (~7 h), and a group of KATANA STML was super-speed-sintered (18 min). Dimensions of the zirconia specimens after sintering were 14.5 mm (diameter) and 1.2 mm (thickness). Translucency was assessed using a colorimeter. Biaxial flexural strength was measured using a universal testing machine, followed by Weibull analysis. Scanning electron microscopy was used for microstructure assessments. X-ray diffraction was used to analyze the crystallography before and after hydrothermal aging. Low-temperature degradation (LTD) tests were performed at 134 °C under 2-3 bar water vapor in an autoclave. RESULTS The translucency and flexural strength were not affected significantly by the sintering programs (p > 0.05). The conventionally sintered KATANA STML and speed-sintered Zpex 4 presented the highest and lowest Weibull modulus, respectively. The conventionally-sintered Y-PSZ had a larger average grain size and smaller fraction of fine grains than those of the speed-sintered specimens. The fractographic analysis of the speed- and conventionally sintered Y-PSZ yielded comparable results. The speed-sintered Y-PSZ exhibited a lower c-ZrO2 content than that of conventionally-sintered Y-PSZ, except for KATANA HT and KATANA STML. LTD tests indicated that some of the speed and conventionally-sintered Y-PSZ exhibited similar monoclinic volume fractions. SIGNIFICANCE Speed-sintering programs are acceptable for Y-PSZ zirconia.
Collapse
|
22
|
Cho MH, Seol HJ. Effect of Cooling Rate during Glazing on the Mechanical and Optical Properties of Monolithic Zirconia with 3 mol% Yttria Content. MATERIALS (BASEL, SWITZERLAND) 2021; 14:7474. [PMID: 34885629 PMCID: PMC8658760 DOI: 10.3390/ma14237474] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/01/2021] [Accepted: 12/02/2021] [Indexed: 11/17/2022]
Abstract
Glazing is the final heat treatment process in the manufacturing of a monolithic zirconia prosthesis. Herein, the effect of cooling rate during zirconia glazing was investigated. A 3 mol% yttria-stabilized tetragonal zirconia polycrystal was glazed at the general cooling rate suggested by the manufacturer, as well as at higher and lower cooling rates, and the differences in flexural strength, hardness, optical properties, and crystal structure were evaluated. A higher cooling rate did not affect the flexural strength, hardness, grain size, optical properties, or crystal structure; however, the Weibull modulus decreased by 1.3. A lower cooling rate did not affect the flexural strength, optical properties, or crystal structure; however, the Weibull characteristic strength increased by 26.7 MPa and the Weibull modulus increased by 0.9. The decrease in hardness and the increase in grain size were statistically significant; however, the numerical differences were negligible. This study revealed that a lower cooling rate provides more reliable flexural strength. Therefore, glazing can proceed at a general cooling rate, which takes 3-4 min; however, glazing at a lower cooling rate will provide a more consistent flexural strength if desired, despite being time-consuming.
Collapse
Affiliation(s)
- Mi-Hyang Cho
- Department of Dental Lab, Wonkwang Health Science University, Iksan-si 54538, Jeonbuk-do, Korea;
| | - Hyo-Joung Seol
- Department of Dental Materials, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan-si 50612, Gyeongsangnam-do, Korea
| |
Collapse
|