1
|
Filchenko I, Duss SB, Salzmann S, Brill AK, Korostovtseva L, Amelina V, Baillieul S, Bernasconi C, Schmidt MH, Bassetti CLA. Early sleep apnea treatment in stroke (eSATIS) - a multicentre, randomised controlled, rater-blinded, clinical trial: The association of post-stroke cognition with sleep-disordered breathing and its treatment. J Sleep Res 2024:e14296. [PMID: 39251407 DOI: 10.1111/jsr.14296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 06/22/2024] [Accepted: 07/13/2024] [Indexed: 09/11/2024]
Abstract
Sleep-disordered breathing (SDB) is linked to cognitive dysfunction. Although SDB is common in stroke patients, the impact of SDB and its early treatment on cognitive functioning after stroke remains poorly investigated. Therefore, we explored the association between SDB and post-stroke cognitive functioning, including the impact of early SDB treatment with adaptive servo-ventilation (ASV) on cognitive recovery from acute event to 3 months post-stroke. We used data from two studies, which included ischaemic stroke patients (n = 131) and no-stroke controls (n = 37) without SDB (apnea-hypopnea index, AHI <5/h) and with SDB (AHI≥20/h). Cognitive functioning was assessed within 7 days and 3 months post-stroke in stroke patients, or at study inclusion in no-stroke control group, respectively. Stroke patients with SDB were randomized to ASV treatment (ASV+) or usual care (ASV-). Linear regression adjusted for main confounders assessed the impact of SDB and its treatment on cognitive recovery. The intention-to-treat analysis did not show significant associations of SDB ASV+ (n = 30) versus SDB ASV- (n = 29) with cognitive recovery. In an exploratory subanalysis, compliant SDB ASV+ (n = 14) versus SDB ASV- showed improvements with ASV in visual memory and cognitive flexibility. Combining the stroke and non-stroke datasets, SDB (n = 85) versus no-SDB (n = 83) was associated with deficits in visual memory and response inhibition independently of stroke. SDB ASV- versus no-SDB (n = 51) was associated with less improvement in visual memory. There was no substantial evidence for benefits of intention-to-treat ASV on cognitive recovery. Exploratory analysis indicated that compliant ASV treatment could benefit visual memory and cognitive flexibility, whereas untreated SDB could contribute to a poor recovery of visual memory.
Collapse
Affiliation(s)
- Irina Filchenko
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Graduate School for Health Sciences, University of Bern, Bern, Switzerland
| | - Simone B Duss
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
| | - Saskia Salzmann
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Graduate School for Health Sciences, University of Bern, Bern, Switzerland
- Division of Neuropaediatrics, Development and Rehabilitation, Department of Paediatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Anne-Kathrin Brill
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Department for Pulmonary Medicine, Allergology and Clinical Immunology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Lyudmila Korostovtseva
- Laboratory of Somnology, Almazov National Medical Research Centre, Sankt-Peterburg, Russia
| | - Valeria Amelina
- Laboratory of Somnology, Almazov National Medical Research Centre, Sankt-Peterburg, Russia
| | - Sébastien Baillieul
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, Grenoble, France
| | - Corrado Bernasconi
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
| | - Markus H Schmidt
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
| | - Claudio L A Bassetti
- Department of Neurology, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
- Interdisciplinary Sleep-Wake-Epilepsy Centre, Bern University Hospital (Inselspital) and University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Chan TG, Plageman J, Yu JL. The Repeatability of Pharyngeal Opening Pressure Under Drug-Induced Sleep Endoscopy. Otolaryngol Head Neck Surg 2024; 171:295-302. [PMID: 38606621 PMCID: PMC11211064 DOI: 10.1002/ohn.730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/01/2024] [Accepted: 02/09/2024] [Indexed: 04/13/2024]
Abstract
OBJECTIVE Pharyngeal opening pressure (PhOP) is a measure of upper airway collapsibility that can be obtained during drug-induced sleep endoscopy (DISE) using a continuous positive airway pressure (CPAP) titration. However, the stability of PhOP over the course of sedation during DISE remains unclear. This study aims to compare repeat measures of PhOP over the course of DISE. STUDY DESIGN Single arm prospective study. SETTING Single tertiary care institution. METHODS Patients had 2 CPAP titrations while undergoing DISE. Collected data included patient demographics, PhOP, patient sedation index (PSI), and duration of and between CPAP titrations. t Tests, test-retest coefficient analysis, and repeated measures correlation were performed. RESULTS Twenty-five patients completed the study between 2022 and 2023 with 22 patients having sedation depth (PSI) recording. Most were male (76%), obese (average body mass index: 30.24 kg/m2), with severe obstructive sleep apnea (average apnea-hypopnea index: 39.8 events/hr). Test-retest analysis showed good-excellent correlation between PhOP values (intraclass correlation coefficient = 0.892, P < .0001, n = 25). Average time between CPAP titrations was 15 minutes to 6 seconds. Over that time, PhOP increased by an average of 0.72 cmH2O (P = .06, n = 25) and PSI decreased by 9.5 units (P = .01, n = 22). Repeated measures correlation showed a weak negative correlation between PhOP and PSI (r = -.45, P = .03, n = 22). CONCLUSION The results showed repeatability of PhOP values over the course of DISE. When adjusted for sedation depth (PSI), deeper sedation was weakly associated with greater PHOP. However, the magnitude of this change was small and we conclude that PhOP remains relatively stable over the course of DISE (Effects of Lung Volume on Upper Airway Patency During DISE [DISE-Pulm], NCT05350332, clinicaltrials.gov).
Collapse
Affiliation(s)
- Tyler G Chan
- Emory University School of Medicine, Atlanta, Georgia, USA
| | - Jack Plageman
- Department of Otolaryngology-Head and Neck Surgery, Emory University, Atlanta, Georgia, USA
| | - Jason L Yu
- Department of Otolaryngology-Head and Neck Surgery, Emory University, Atlanta, Georgia, USA
| |
Collapse
|
3
|
Huang P, Tang Q, Yang X, Li M, Li S. Effects of oropharyngeal exercises on CPAP compliance: A prospective intervention study. Am J Otolaryngol 2024; 45:104274. [PMID: 38593552 DOI: 10.1016/j.amjoto.2024.104274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 03/26/2024] [Indexed: 04/11/2024]
Abstract
PURPOSE To investigate the effects of oropharyngeal exercise on continuous positive airway pressure (CPAP) compliance in patients with moderate to severe obstructive sleep apnea over a period of 6 months. MATERIALS AND METHODS This study was conducted as a prospective, observational, and interventional investigation. A total of 70 patients with moderate to severe obstructive sleep apnea were randomly assigned to either the oropharyngeal exercise group (n = 44) or the sham-therapy group (n = 26). The compliance of the enrolled patients with CPAP therapy was assessed at baseline, 3-month follow-up and 6-month follow-up. Objective sleep data, questionnaire and CPAP use time were collected over a half-year period (i.e., baseline, 6 months, and 12 months). RESULTS The study found that the average use time of CPAP within one month was significantly longer in the oropharyngeal exercises group compared to the sham-therapy group at the 3-month assessment (5.5 ± 1.2 vs 4.8 ± 1.3 h per night; p=0.030), and much significantly longer at 6-months assessment (6.0 ± 1.4 vs 4.9 ± 1.3 h per night; p=0.001). Furthermore, the average use time of CPAP increased over time, with the oropharyngeal exercises group exhibiting a more pronounced growth from baseline to the six-month follow-up (4.8 ± 1.0 h per night to 6.0 ± 1.3 h per night, p < 0.001) compared to the sham-therapy group (4.8 ± 1.3 h per night to 4.9 ± 1.3 h per night, p=0.952). Additionally, the oropharyngeal exercise group demonstrated an improvement in the Epworth sleepiness scale compared to the sham-therapy group at the 3-month follow-up (6.0 ± 2.0 vs 8.8 ± 3.2; p < 0.001), as well as decreased significantly at 6-month follow-up (p = 0.032). CONCLUSIONS CPAP adherence can be improved with oropharyngeal exercises therapy among moderate to severe OSA patients. Notably, the average duration of CPAP usage and reduction in daytime sleepiness were maintained even after six months of oropharyngeal exercise therapy.
Collapse
Affiliation(s)
- Peiying Huang
- Department of Otolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China
| | - Qinglai Tang
- Department of Otolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China
| | - Xinming Yang
- Department of Otolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China
| | - Mengmeng Li
- Department of Otolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China
| | - Shisheng Li
- Department of Otolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China.
| |
Collapse
|
4
|
Testelmans D, Kalkanis A, Papadopoulos D, Demolder S, Buyse B. Central sleep apnea: emphasizing recognition and differentiation. Expert Rev Respir Med 2024; 18:309-320. [PMID: 38878064 DOI: 10.1080/17476348.2024.2369256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 06/13/2024] [Indexed: 06/19/2024]
Abstract
INTRODUCTION Central sleep apnea (CSA) is a sleep-related breathing disorder in which the effort to breathe is intermittently diminished or absent. CSA is a common disorder among patients with different cardiovascular disorders, including heart failure. In addition, a growing number of medications have been shown to induce CSA and CSA can emerge after initiation of treatment for obstructive sleep apnea. Accumulating evidence shows that CSA is a heterogeneous disorder with individual differences in clinical and biological characteristics and/or underlying pathophysiological mechanisms. AREAS COVERED This narrative review offers an overview of the diagnostic aspects and classification of CSA, with an emphasis on heart failure patients, patients with CSA due to a medication and treatment-emergent CSA. The importance of evaluation of prognostic biomarkers in patients with different types of CSA is discussed. This narrative review synthesizes literature on CSA sourced from the PubMed database up to February 2024. EXPERT OPINION CSA presents a remarkably diverse disorder, with treatment modalities exhibiting potentially varied efficacy across its various phenotypes. This highlights the imperative for tailored management strategies that are rooted in phenotype classification.
Collapse
Affiliation(s)
- Dries Testelmans
- Department of Pneumology, Leuven University Center for Sleep and Wake disorders, University Hospitals Leuven, Leuven, Belgium
- Laboratory of Respiratory Diseases and Thoracic Surgery (BREATHE), Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium
| | - Alexandros Kalkanis
- Department of Pneumology, Leuven University Center for Sleep and Wake disorders, University Hospitals Leuven, Leuven, Belgium
| | - Dimitrios Papadopoulos
- Department of Pneumology, Leuven University Center for Sleep and Wake disorders, University Hospitals Leuven, Leuven, Belgium
| | - Saartje Demolder
- Department of Pneumology, Leuven University Center for Sleep and Wake disorders, University Hospitals Leuven, Leuven, Belgium
| | - Bertien Buyse
- Department of Pneumology, Leuven University Center for Sleep and Wake disorders, University Hospitals Leuven, Leuven, Belgium
- Laboratory of Respiratory Diseases and Thoracic Surgery (BREATHE), Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium
| |
Collapse
|
5
|
Kendzerska T, Szyszkowicz M, Saymeh M, Mallick R, Carlsten C, Ayas NT, Laratta CR, Orach J, Dales R. Air pollution, weather and positive airway pressure treatment adherence in adults with sleep apnea: a retrospective community-based repeated-measures longitudinal study. J Sleep Res 2024:e14183. [PMID: 38439127 DOI: 10.1111/jsr.14183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/15/2024] [Accepted: 02/12/2024] [Indexed: 03/06/2024]
Abstract
We assessed the relation between air pollution, weather, and adherence to positive airway pressure (PAP) therapy in a retrospective community-based repeated-measures study of adults with obstructive sleep apnea who purchased PAP devices from a registered provider between 2013 and 2017 (Ottawa, Ontario, Canada) and had at least one day of data. Daily PAP-derived data, air pollution, and weather databases were linked using postal code. The exposures were mean nocturnal (8:00 p.m. to 8:00 a.m.) (i) residential concentrations of nitrogen dioxide (NO2 ), fine particulate matter <=2.5 μm (PM2.5 ), ozone (O3 ), and Air Quality Health Index (AQHI), and (ii) temperature, relative humidity, and barometric pressure. Covariates in the main model were demographics, season, exposure year, and PAP therapy mode. We analysed 8148 adults (median age of 54 years and 61% men) and 2,071,588 days of data. Based on daily data, the median (interquartile range) daily PAP usage was 416 (323-487) min. Using mixed-effect regression analyses to incorporate daily data and clustering by individuals, we found a statistically significant decrease in adherence for increased levels of NO2 , PM2.5 , and AQHI. The largest effect was for NO2 : a decrease in daily PAP use while comparing the highest versus lowest quartiles (Qs) was 3.4 (95% confidence interval [CI] 2.8-3.9) min. Decreased PAP adherence was also associated with increased temperature (Q4 versus Q1: 2.6 [95% CI: 1.5-3.7] min) and decreased barometric pressure (Q1 versus Q4: 2.0 [95% CI 1.5-2.5] min). We observed modest but statistically significant acute effects of air pollution and weather on daily PAP adherence.
Collapse
Affiliation(s)
- Tetyana Kendzerska
- Faculty of Medicine, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada
- The Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
| | - Mieczysław Szyszkowicz
- Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Healthy Canada, Ottawa, Ontario, Canada
| | - Mouaz Saymeh
- The Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
| | | | - Christopher Carlsten
- Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Najib T Ayas
- Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Cheryl R Laratta
- Department of Medicine, University of Alberta, Edmonton, Alberta, Canada
| | - Juma Orach
- Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Robert Dales
- Faculty of Medicine, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada
- The Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
- Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Healthy Canada, Ottawa, Ontario, Canada
| |
Collapse
|
6
|
Pépin JL, Tamisier R, Benjafield AV, Rinder P, Lavergne F, Josseran A, Sinel-Boucher P, Cistulli PA, Malhotra A, Hornus P, Bailly S. CPAP resumption after a first termination and impact on all-cause mortality in France. Eur Respir J 2024; 63:2301171. [PMID: 38135441 PMCID: PMC10831141 DOI: 10.1183/13993003.01171-2023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 11/26/2023] [Indexed: 12/24/2023]
Abstract
BACKGROUND Continuation of continuous positive airway pressure (CPAP) therapy after initial prescription has been shown to reduce all-cause mortality versus therapy termination. However, there is a lack of data on the rates and impact of resuming CPAP in patients with obstructive sleep apnoea (OSA). This analysis determined the prevalence of CPAP resumption in the year after termination, characterised determinants of CPAP resumption, and examined the impact of CPAP resumption on all-cause mortality. METHODS French national health insurance reimbursement system data for adults aged ≥18 years were used. CPAP prescription was identified by specific treatment codes. Patients who resumed CPAP after first therapy termination and continued to use CPAP for 1 year were matched with those who resumed CPAP then terminated therapy for a second time. RESULTS Out of 103 091 individuals with a first CPAP termination, 26% resumed CPAP over the next 12 months, and 65% of these were still using CPAP 1 year later. Significant predictors of CPAP continuation after resumption included male sex, hypertension and CPAP prescription by a pulmonologist. In the matched population, the risk of all-cause death was 38% lower in individuals who continued using CPAP after therapy resumption versus those who had a second therapy discontinuation (hazard ratio 0.62, 95% CI 0.48-0.79; p=0.0001). CONCLUSION These data suggest that individuals with OSA who fail initial therapy with CPAP should be offered a second trial with the device to ensure that effective therapy is not withheld from those who might benefit.
Collapse
Affiliation(s)
- Jean-Louis Pépin
- University Grenoble Alpes, Inserm, CHU Grenoble Alpes, HP2, Grenoble, France
| | - Renaud Tamisier
- University Grenoble Alpes, Inserm, CHU Grenoble Alpes, HP2, Grenoble, France
| | | | | | | | | | | | - Peter A Cistulli
- Charles Perkins Centre, Faculty of Medicine and Health, University Sydney, Sydney, Australia
- Department of Respiratory Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Atul Malhotra
- University of California San Diego, San Diego, CA, USA
| | | | - Sébastien Bailly
- University Grenoble Alpes, Inserm, CHU Grenoble Alpes, HP2, Grenoble, France
| |
Collapse
|
7
|
Tamisier R, Damy T, Bailly S, Goutorbe F, Davy JM, Lavergne F, Palot A, Verbraecken JA, d'Ortho MP, Pépin JL, d'Ortho MP, Pépin JL, Davy JM, Damy T, Tamisier R. FACE study: 2-year follow-up of adaptive servo-ventilation for sleep-disordered breathing in a chronic heart failure cohort. Sleep Med 2024; 113:412-421. [PMID: 37612192 DOI: 10.1016/j.sleep.2023.07.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 07/10/2023] [Accepted: 07/14/2023] [Indexed: 08/25/2023]
Abstract
BACKGROUND Sleep-disordered breathing (SDB) is a common comorbidity in patients with heart failure (HF) and is associated with worse prognosis. OBJECTIVES This study evaluated the effects of adaptive servo-ventilation (ASV) on morbidity and mortality in a large heterogeneous population of HF patients with different etiologies/phenotypes. METHODS Consecutive HF patients with predominant central sleep apnea (± obstructive sleep apnea) indicated for ASV were included; the control group included patients who refused or stopped ASV before three months follow-up. Six homogenous clusters were determined using the latent class analysis (LCA) method. The primary endpoint was time to composite first event (all-cause death, lifesaving cardiovascular intervention, or unplanned hospitalization for worsening of chronic HF). RESULTS Of 503 patients at baseline, 324 underwent 2-year follow-up. Compared to control group, 2-year primary endpoint event-free survival was significantly greater in patients in ASV group only in univariable analysis (1.67, 95% [1.12-2.49]; p = 0.01). Secondary endpoints, event-free of cardiovascular death or heart failure-related hospitalization and all-cause death or all-cause hospitalization were positively impacted by ASV (univariate and multivariable analysis). LCA identified two groups, with preserved and mid-range left ventricular ejection fraction (LVEF) and severe hypoxia, in whom ASV increase prognosis benefit. CONCLUSIONS Patients with HF and SDB are a highly heterogeneous group identified using LCA. Systematic deep phenotyping is essential to ensure that ASV is prescribed to those benefit from therapy, as ASV use in patients with severe hypoxic burden and those with HFpEF was associated with a significant reduction in cardiovascular events and mortality. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/ct2/show/NCT01831128.
Collapse
Affiliation(s)
- Renaud Tamisier
- Univ. Grenoble Alpes, Inserm 1300, HP2, Grenoble, France; Service Hospitalo-Universitaire Pneumologie et Physiologie, Pole Thorax et Vaisseaux, CHU de Grenoble Alpes, Grenoble, France.
| | - Thibaud Damy
- Service de Cardiologie, Centre de Référence Amyloses Cardiaques, GRC ARI, DHU ATVB, AP-HP, Hôpital Henri Mondor, Créteil, France; UFR médecine Université Paris-Est Créteil, France; Unité INSERM U981, Créteil, France
| | - Sébastien Bailly
- Univ. Grenoble Alpes, Inserm 1300, HP2, Grenoble, France; Service Hospitalo-Universitaire Pneumologie et Physiologie, Pole Thorax et Vaisseaux, CHU de Grenoble Alpes, Grenoble, France
| | | | - Jean-Marc Davy
- Service de Cardiologie, CHU, Montpellier, France; UFR Médecine Université Montpellier, France
| | | | | | - Johan A Verbraecken
- Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital and University of Antwerp, Antwerp, Belgium
| | - Marie-Pia d'Ortho
- Université de Paris, Neuro Diderot, Inserm, Paris, France; Département de Physiologie - Explorations Fonctionnelles, AP-HP, Hôpital Bichat, Paris, France
| | - Jean-Louis Pépin
- Univ. Grenoble Alpes, Inserm 1300, HP2, Grenoble, France; Service Hospitalo-Universitaire Pneumologie et Physiologie, Pole Thorax et Vaisseaux, CHU de Grenoble Alpes, Grenoble, France
| | - Marie-Pia d'Ortho
- Université de Paris, Neuro Diderot, Inserm, Paris, France; Département de Physiologie - Explorations Fonctionnelles, AP-HP, Hôpital Bichat, Paris, France
| | - Jean-Louis Pépin
- Univ. Grenoble Alpes, Inserm 1300, HP2, Grenoble, France; Service Hospitalo-Universitaire Pneumologie et Physiologie, Pole Thorax et Vaisseaux, CHU de Grenoble Alpes, Grenoble, France
| | - Jean-Marc Davy
- Service de Cardiologie, CHU, Montpellier, France; UFR Médecine Université Montpellier, France
| | - Thibaud Damy
- Service de Cardiologie, Centre de Référence Amyloses Cardiaques, GRC ARI, DHU ATVB, AP-HP, Hôpital Henri Mondor, Créteil, France; UFR médecine Université Paris-Est Créteil, France; Unité INSERM U981, Créteil, France
| | - Renaud Tamisier
- Univ. Grenoble Alpes, Inserm 1300, HP2, Grenoble, France; Service Hospitalo-Universitaire Pneumologie et Physiologie, Pole Thorax et Vaisseaux, CHU de Grenoble Alpes, Grenoble, France
| |
Collapse
|
8
|
Locke BW, Sellman J, McFarland J, Uribe F, Workman K, Sundar KM. Predictors of Initial CPAP Prescription and Subsequent Course with CPAP in Patients with Central Sleep Apneas at a Single Center. Lung 2023; 201:625-634. [PMID: 37987861 PMCID: PMC10869204 DOI: 10.1007/s00408-023-00657-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 11/07/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE Guidelines recommend considering an initial trial of continuous positive airway pressure (CPAP) to treat central sleep apnea (CSA). However, practice patterns vary widely. This study investigated predictors for an initial trial of CPAP in patients with central apneas and whether those factors predict adequate treatment response in patients receiving an initial CPAP trial. METHODS Charts of patients receiving a diagnostic code for CSA following a sleep study during 2016-2018 at a single center were reviewed. Patient factors, initial treatment prescriptions, and subsequent changes to therapy were extracted from electronic health records. Regression models were used to estimate factors associated with an initial CPAP prescription and the likelihood of an adequate CPAP response (no subsequent therapy change and no discontinuation of therapy) among patients prescribed CPAP. RESULTS 429/588 (73%) patients with central apneas received an initial trial of CPAP. Younger age, diagnosis by home sleep testing, non-opiate etiology of central apneas, and a lower proportion of central apneas at diagnosis were independently associated with a higher likelihood of an initial CPAP trial. A lower proportion of central apneas was associated with a higher probability of adequate response, while current smoking and opiate-related central apneas predicted an unsuccessful CPAP trial. A new finding was that older age predicted a lower likelihood of an initial CPAP prescription but did not predict an unsatisfactory response to CPAP. CONCLUSION Clinicians may incorrectly weigh certain clinical and sleep study characteristics when deciding whether to trial CPAP for patients with central apneas.
Collapse
Affiliation(s)
- Brian W Locke
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Utah, Salt Lake City, UT, USA
| | - Jeffrey Sellman
- Division of Pulmonary and Critical Care, Department of Internal Medicine, Boston University, Boston, MA, USA
| | - Jonathan McFarland
- Department of Internal Medicine, Michigan State University, East Lansing, MI, USA
| | - Francisco Uribe
- Department of Psychiatry, Texas Tech University Health Sciences Center, El Paso, TX, USA
| | - Kimberly Workman
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Utah, Salt Lake City, UT, USA
| | - Krishna M Sundar
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
9
|
Locke BW, Sellman J, McFarland J, Uribe F, Workman K, Sundar KM. Predictors of Initial CPAP Prescription and Subsequent Course with CPAP in Patients with Central Sleep Apneas. RESEARCH SQUARE 2023:rs.3.rs-3199807. [PMID: 37547021 PMCID: PMC10402256 DOI: 10.21203/rs.3.rs-3199807/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Purpose Guidelines recommend considering an initial trial of continuous positive airway pressure (CPAP) to treat central sleep apnea (CSA). However, practice patterns vary widely. This study investigated predictors for an initial trial of CPAP in patients with central apneas and whether those factors predict adequate treatment response in patients receiving an initial CPAP trial. Methods Charts of patients receiving a diagnostic code for CSA following a sleep study during 2016-2018 at a single center were reviewed. Patient factors, initial treatment prescriptions, and subsequent changes to therapy were extracted from electronic health records. Regression models were used to estimate factors associated with an initial CPAP prescription and the likelihood of an adequate CPAP response (no subsequent therapy change or nonadherence) among patients prescribed CPAP. Results 429/588 (73%) patients with central apneas received an initial trial of CPAP. Younger age, diagnosis by home sleep testing, non-opiate etiology of central apneas, and a lower proportion of central apneas at diagnosis were independently associated with a higher likelihood of an initial CPAP trial. A lower proportion of central apneas was associated with a higher probability of adequate response, while current smoking and opiate-related central apneas predicted an unsuccessful CPAP trial. A new finding was that older age predicted a lower likelihood of an initial CPAP prescription but did not predict a suboptimal response to CPAP. Conclusion Clinicians may incorrectly weigh certain clinical and sleep study characteristics when deciding whether to trial CPAP for patients with central apneas.
Collapse
|
10
|
Chang JL, Goldberg AN, Alt JA, Alzoubaidi M, Ashbrook L, Auckley D, Ayappa I, Bakhtiar H, Barrera JE, Bartley BL, Billings ME, Boon MS, Bosschieter P, Braverman I, Brodie K, Cabrera-Muffly C, Caesar R, Cahali MB, Cai Y, Cao M, Capasso R, Caples SM, Chahine LM, Chang CP, Chang KW, Chaudhary N, Cheong CSJ, Chowdhuri S, Cistulli PA, Claman D, Collen J, Coughlin KC, Creamer J, Davis EM, Dupuy-McCauley KL, Durr ML, Dutt M, Ali ME, Elkassabany NM, Epstein LJ, Fiala JA, Freedman N, Gill K, Boyd Gillespie M, Golisch L, Gooneratne N, Gottlieb DJ, Green KK, Gulati A, Gurubhagavatula I, Hayward N, Hoff PT, Hoffmann OM, Holfinger SJ, Hsia J, Huntley C, Huoh KC, Huyett P, Inala S, Ishman SL, Jella TK, Jobanputra AM, Johnson AP, Junna MR, Kado JT, Kaffenberger TM, Kapur VK, Kezirian EJ, Khan M, Kirsch DB, Kominsky A, Kryger M, Krystal AD, Kushida CA, Kuzniar TJ, Lam DJ, Lettieri CJ, Lim DC, Lin HC, Liu SY, MacKay SG, Magalang UJ, Malhotra A, Mansukhani MP, Maurer JT, May AM, Mitchell RB, Mokhlesi B, Mullins AE, Nada EM, Naik S, Nokes B, Olson MD, Pack AI, Pang EB, Pang KP, Patil SP, Van de Perck E, Piccirillo JF, Pien GW, Piper AJ, Plawecki A, Quigg M, Ravesloot MJ, Redline S, Rotenberg BW, Ryden A, Sarmiento KF, Sbeih F, Schell AE, Schmickl CN, Schotland HM, Schwab RJ, Seo J, Shah N, Shelgikar AV, Shochat I, Soose RJ, Steele TO, Stephens E, Stepnowsky C, Strohl KP, Sutherland K, Suurna MV, Thaler E, Thapa S, Vanderveken OM, de Vries N, Weaver EM, Weir ID, Wolfe LF, Tucker Woodson B, Won CH, Xu J, Yalamanchi P, Yaremchuk K, Yeghiazarians Y, Yu JL, Zeidler M, Rosen IM. International Consensus Statement on Obstructive Sleep Apnea. Int Forum Allergy Rhinol 2023; 13:1061-1482. [PMID: 36068685 PMCID: PMC10359192 DOI: 10.1002/alr.23079] [Citation(s) in RCA: 76] [Impact Index Per Article: 76.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 08/12/2022] [Accepted: 08/18/2022] [Indexed: 11/08/2022]
Abstract
BACKGROUND Evaluation and interpretation of the literature on obstructive sleep apnea (OSA) allows for consolidation and determination of the key factors important for clinical management of the adult OSA patient. Toward this goal, an international collaborative of multidisciplinary experts in sleep apnea evaluation and treatment have produced the International Consensus statement on Obstructive Sleep Apnea (ICS:OSA). METHODS Using previously defined methodology, focal topics in OSA were assigned as literature review (LR), evidence-based review (EBR), or evidence-based review with recommendations (EBR-R) formats. Each topic incorporated the available and relevant evidence which was summarized and graded on study quality. Each topic and section underwent iterative review and the ICS:OSA was created and reviewed by all authors for consensus. RESULTS The ICS:OSA addresses OSA syndrome definitions, pathophysiology, epidemiology, risk factors for disease, screening methods, diagnostic testing types, multiple treatment modalities, and effects of OSA treatment on multiple OSA-associated comorbidities. Specific focus on outcomes with positive airway pressure (PAP) and surgical treatments were evaluated. CONCLUSION This review of the literature consolidates the available knowledge and identifies the limitations of the current evidence on OSA. This effort aims to create a resource for OSA evidence-based practice and identify future research needs. Knowledge gaps and research opportunities include improving the metrics of OSA disease, determining the optimal OSA screening paradigms, developing strategies for PAP adherence and longitudinal care, enhancing selection of PAP alternatives and surgery, understanding health risk outcomes, and translating evidence into individualized approaches to therapy.
Collapse
Affiliation(s)
- Jolie L. Chang
- University of California, San Francisco, California, USA
| | | | | | | | - Liza Ashbrook
- University of California, San Francisco, California, USA
| | | | - Indu Ayappa
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | - Maurits S. Boon
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Pien Bosschieter
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Itzhak Braverman
- Hillel Yaffe Medical Center, Hadera Technion, Faculty of Medicine, Hadera, Israel
| | - Kara Brodie
- University of California, San Francisco, California, USA
| | | | - Ray Caesar
- Stone Oak Orthodontics, San Antonio, Texas, USA
| | | | - Yi Cai
- University of California, San Francisco, California, USA
| | | | | | | | | | | | | | | | | | - Susmita Chowdhuri
- Wayne State University and John D. Dingell VA Medical Center, Detroit, Michigan, USA
| | - Peter A. Cistulli
- Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | - David Claman
- University of California, San Francisco, California, USA
| | - Jacob Collen
- Uniformed Services University, Bethesda, Maryland, USA
| | | | | | - Eric M. Davis
- University of Virginia, Charlottesville, Virginia, USA
| | | | | | - Mohan Dutt
- University of Michigan, Ann Arbor, Michigan, USA
| | - Mazen El Ali
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | - Kirat Gill
- Stanford University, Palo Alto, California, USA
| | | | - Lea Golisch
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | | | | | - Arushi Gulati
- University of California, San Francisco, California, USA
| | | | | | - Paul T. Hoff
- University of Michigan, Ann Arbor, Michigan, USA
| | - Oliver M.G. Hoffmann
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | | | - Jennifer Hsia
- University of Minnesota, Minneapolis, Minnesota, USA
| | - Colin Huntley
- Sidney Kimmel Medical Center at Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | | | | | - Sanjana Inala
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | | | | | | | | | | | | | | | - Meena Khan
- Ohio State University, Columbus, Ohio, USA
| | | | - Alan Kominsky
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | - Meir Kryger
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Derek J. Lam
- Oregon Health and Science University, Portland, Oregon, USA
| | | | | | | | | | | | | | - Atul Malhotra
- University of California, San Diego, California, USA
| | | | - Joachim T. Maurer
- University Hospital Mannheim, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
| | - Anna M. May
- Case Western Reserve University, Cleveland, Ohio, USA
| | - Ron B. Mitchell
- University of Texas, Southwestern and Children’s Medical Center Dallas, Texas, USA
| | | | | | | | | | - Brandon Nokes
- University of California, San Diego, California, USA
| | | | - Allan I. Pack
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | | | | - Mark Quigg
- University of Virginia, Charlottesville, Virginia, USA
| | | | - Susan Redline
- Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Armand Ryden
- Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | | | - Firas Sbeih
- Cleveland Clinic Head and Neck Institute, Cleveland, Ohio, USA
| | | | | | | | | | - Jiyeon Seo
- University of California, Los Angeles, California, USA
| | - Neomi Shah
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | | | | | - Ryan J. Soose
- University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | - Erika Stephens
- University of California, San Francisco, California, USA
| | | | | | | | | | - Erica Thaler
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Sritika Thapa
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | - Nico de Vries
- Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | | | - Ian D. Weir
- Yale School of Medicine, New Haven, Connecticut, USA
| | | | | | | | - Josie Xu
- University of Toronto, Ontario, Canada
| | | | | | | | | | | | - Ilene M. Rosen
- University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
11
|
Mendelson M, Duval J, Bettega F, Tamisier R, Baillieul S, Bailly S, Pépin JL. The individual and societal price of non-adherence to continuous positive airway pressure, contributors and strategies for improvement. Expert Rev Respir Med 2023; 17:305-317. [PMID: 37045746 DOI: 10.1080/17476348.2023.2202853] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
INTRODUCTION Continuous positive airway pressure (CPAP) is the first line therapy for obstructive sleep apnea (OSA). CPAP is highly effective for improving symptoms and quality of life but the major issue is adherence, with up to 50% of OSA discontinuing CPAP in the first 3 years after CPAP initiation. AREAS COVERED We present the individual and societal cost of non-adherence to CPAP, factors associated with non-adherence to CPAP, as well as current strategies for improving adherence including telehealth, couples-based interventions and behavioral interventions. We also report on challenges and pitfalls for the visualization and analysis of CPAP remote monitoring platforms. EXPERT OPINION CPAP termination rates and adherence to therapy remain major issues despite technical improvements in CPAP devices. The individual and societal price of non-adherence to CPAP for OSA patients goes beyond excessive sleepiness and includes cardiovascular events, all-cause mortality, and increased health costs. Strategies for improving CPAP adherence should be individually tailored and aim to also improve lifestyle habits including physical activity and nutrition. Access to these strategies should be supported by refining visualization dashboards of CPAP remote monitoring platforms, and by disseminating telehealth and innovative analytics, including artificial intelligence.
Collapse
Affiliation(s)
- Monique Mendelson
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
| | - Jeremy Duval
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
- LVL Médical, 44 Quai Charles de Gaulle Lyon, France
| | - François Bettega
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
| | - Renaud Tamisier
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
| | | | - Sébastien Bailly
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
| | - Jean-Louis Pépin
- HP2 Laboratory, Inserm U1300, Grenoble Alps University, Grenoble, France
| |
Collapse
|
12
|
Correia S, Sousa S, Drummond M, Pinto P, Staats R, Brito D, Lousada N, Cardoso JS, Moita J. Diagnostic and therapeutic approach of central sleep apnea in heart failure - the role of adaptive servo-ventilation. A statement of the Portuguese society of pulmonology and the Portuguese sleep association. Pulmonology 2023; 29:138-143. [PMID: 35501278 DOI: 10.1016/j.pulmoe.2021.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 11/30/2021] [Accepted: 12/01/2021] [Indexed: 10/18/2022] Open
Abstract
It is known that patients with heart failure (HF) have an increased risk of developing central sleep apnoea (CSA), with Cheyne-Stokes respiration. The development of servo-ventilation aimed to treat CSA and improve the quality of life (QoL) of these patients. A large randomized clinical study, SERVE-HF, was conducted in order to test this theory in patients with HF and reduced ejection fraction (HFrEF). The results from this trial seemed to indicate that, in these patients, there was no beneficial effect of the assisted ventilation in CSA treatment. More surprisingly, an increased rate of all-cause or cardiovascular mortality was observed. This has led to dramatic changes in clinical practice, with decreased frequency of servo-ventilation prescription across Europe, including Portugal, due to changes in the guidelines. However, SERVE-HF was conducted only in severe systolic HF patients with CSA, and caution must be taken when extrapolating these results to HF patients with preserved ejection fraction or CSA patients without HF. The study also showed poor adherence, methodological and statistical gaps, including study design, patient selection, data collection and analysis, treatment adherence, and group crossovers, which have not been discussed in the trial as potential confounding factors and raise several concerns. Moreover, the adaptive servo-ventilation (ASV) device used in SERVE-HF was unable to lower the minimum support pressure below 3 mm H20, and this has been suggested as one of the probable contributing reasons to the excess mortality observed in this study. This limitation has since been solved, and this ASV device is no longer used. This paper describes the results of a Portuguese Task Force on the treatment of central sleep apnoea in patients with chronic HF.
Collapse
Affiliation(s)
- S Correia
- Hospital Pedro Hispano, Porto, Portugal.
| | - S Sousa
- Centro Hospitalar de Setubal, Portugal
| | - M Drummond
- Centro Hospitalar Universitario do Porto, Porto, Portugal
| | - P Pinto
- Centro Hospitalar Universitario Lisboa Norte, Lisboa, Portugal
| | - R Staats
- Centro Hospitalar Universitario Lisboa Norte, Lisboa, Portugal
| | - D Brito
- Centro Hospitalar Universitario Lisboa Norte, Lisboa, Portugal
| | - N Lousada
- Centro Hospitalar Universitario Lisboa Norte, Lisboa, Portugal
| | - J S Cardoso
- Centro Hospitalar Universitário de São João, Portugal
| | - J Moita
- Centro Hospitalar e Universitario de Coimbra, Portugal
| |
Collapse
|
13
|
Duarte RLDM, Togeiro SMGP, Palombini LDO, Rizzatti FPG, Fagondes SC, Magalhães-da-Silveira FJ, Cabral MM, Genta PR, Lorenzi-Filho G, Clímaco DCS, Drager LF, Codeço VM, Viegas CADA, Rabahi MF. Brazilian Thoracic Association Consensus on Sleep-disordered Breathing. JORNAL BRASILEIRO DE PNEUMOLOGIA : PUBLICACAO OFICIAL DA SOCIEDADE BRASILEIRA DE PNEUMOLOGIA E TISILOGIA 2022; 48:e20220106. [PMID: 35830079 PMCID: PMC9262434 DOI: 10.36416/1806-3756/e20220106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 05/23/2022] [Indexed: 12/02/2022]
Abstract
Sleep is essential for the proper functioning of all individuals. Sleep-disordered breathing can occur at any age and is a common reason for medical visits. The objective of this consensus is to update knowledge about the main causes of sleep-disordered breathing in adult and pediatric populations, with an emphasis on obstructive sleep apnea. Obstructive sleep apnea is an extremely prevalent but often underdiagnosed disease. It is often accompanied by comorbidities, notably cardiovascular, metabolic, and neurocognitive disorders, which have a significant impact on quality of life and mortality rates. Therefore, to create this consensus, the Sleep-Disordered Breathing Department of the Brazilian Thoracic Association brought together 14 experts with recognized, proven experience in sleep-disordered breathing.
Collapse
Affiliation(s)
| | - Sonia Maria Guimarães Pereira Togeiro
- . Disciplina de Clínica Médica, Escola Paulista de Medicina - EPM - Universidade Federal de São Paulo - UNIFESP - São Paulo (SP) Brasil.,. Instituto do Sono, São Paulo (SP) Brasil
| | | | | | - Simone Chaves Fagondes
- . Serviço de Pneumologia, Hospital de Clínicas de Porto Alegre, Universidade Federal do Rio Grande do Sul - UFRGS - Porto Alegre (RS) Brasil
| | | | | | - Pedro Rodrigues Genta
- . Laboratório de Investigação Médica 63 - LIM 63 (Laboratório do Sono) - Divisão de Pneumologia, Instituto do Coração - InCor - Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo - HCFMUSP - São Paulo (SP) Brasil
| | - Geraldo Lorenzi-Filho
- . Laboratório de Investigação Médica 63 - LIM 63 (Laboratório do Sono) - Divisão de Pneumologia, Instituto do Coração - InCor - Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo - HCFMUSP - São Paulo (SP) Brasil
| | | | - Luciano Ferreira Drager
- . Unidade de Hipertensão, Instituto do Coração - InCor - Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo - HCFMUSP - São Paulo (SP) Brasil
| | - Vitor Martins Codeço
- . Hospital Regional da Asa Norte, Secretaria de Estado de Saúde do Distrito Federal, Brasília (DF) Brasil
| | | | - Marcelo Fouad Rabahi
- . Faculdade de Medicina, Universidade Federal de Goiás - UFG - Goiânia (GO) Brasil
| |
Collapse
|
14
|
Roberts EG, Raphelson JR, Orr JE, LaBuzetta JN, Malhotra A. The Pathogenesis of Central and Complex Sleep Apnea. Curr Neurol Neurosci Rep 2022; 22:405-412. [PMID: 35588042 PMCID: PMC9239939 DOI: 10.1007/s11910-022-01199-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/19/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE The purpose of this article is to review the recent literature on central apnea. Sleep disordered breathing (SDB) is characterized by apneas (cessation in breathing), and hypopneas (reductions in breathing), that occur during sleep. Central sleep apnea (CSA) is sleep disordered breathing in which there is an absence or diminution of respiratory effort during breathing disturbances while asleep. In obstructive sleep apnea (OSA), on the other hand, there is an absence of flow despite ongoing ventilatory effort. RECENT FINDINGS Central sleep apnea is a heterogeneous disease with multiple clinical manifestations. OSA is by far the more common condition; however, CSA is highly prevalent among certain patient groups. Complex sleep apnea (CompSA) is defined as the occurrence/emergence of CSA upon treatment of OSA. Similarly, there is considerable overlap between CSA and OSA in pathogenesis as well as impacts. Thus, understanding sleep disordered breathing is important for many practicing clinicians.
Collapse
Affiliation(s)
- Erin Grattan Roberts
- Department of Medicine, University of California San Diego, 9500 Gilman Drive, La Jolla, San Diego, CA, 92037, USA.
| | - Janna R Raphelson
- Department of Medicine, University of California San Diego, 9500 Gilman Drive, La Jolla, San Diego, CA, 92037, USA
| | - Jeremy E Orr
- Division of Critical Care, Sleep Medicine and Physiology, Department of Medicine, University of California San Diego, San Diego, CA, USA
| | - Jamie Nicole LaBuzetta
- Division of Neurocritical Care, Department of Neurosciences, University of California San Diego, San Diego, CA, USA
| | - Atul Malhotra
- Division of Critical Care, Sleep Medicine and Physiology, Department of Medicine, University of California San Diego, San Diego, CA, USA
| |
Collapse
|
15
|
Johnson KG, Johnson DC. CPAP set-up by mail: we're not there yet. J Clin Sleep Med 2022; 18:1897-1898. [PMID: 35698726 PMCID: PMC9340598 DOI: 10.5664/jcsm.10150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Karin G Johnson
- Department of Neurology- Baystate Medical Center, University of Massachusetts Medical School-Baystate, Springfield, MA.,Institute for Healthcare Delivery and Population Science and Department of Medicine- University of Massachusetts Medical School - Baystate, Springfield, MA
| | - Douglas C Johnson
- Department of Medicine- Baystate Medical Center, University of Massachusetts Medical School-Baystate Springfield, MA
| |
Collapse
|
16
|
Liu S, Li S, Li M, Zeng S, Chen B, Zhang L. Evaluation of the Ocular Surface and Meibomian Gland in Obstructive Sleep Apnea Hypopnea Syndrome. Front Med (Lausanne) 2022; 9:832954. [PMID: 35223929 PMCID: PMC8863666 DOI: 10.3389/fmed.2022.832954] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 01/14/2022] [Indexed: 12/03/2022] Open
Abstract
Purpose To assess the ocular surface and meibomian gland (MG) of patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and to explore the effects of surgery for OSAHS on the ocular surface and MG. Methods Based on the apnea hypopnea index (AHI), 21 patients with mild OSAHS (Group A, 5/h ≤ AHI < 15/h), 20 patients with moderate OSAHS (Group B, 15/h ≤ AHI < 30/h), 62 patients with severe OSAHS (Group C, AHI ≥ 30/h) were examined. The ocular surface and MG were evaluated using Keratograph 5M. In addition, detailed Ophthalmic examination including visual acuity, refraction, slit-lamp examination of the anterior segment, corneal fluorescein staining (CFS), ocular surface disease index (OSDI) scoring, Schirmer I test (SIT) and serum lipid measurement was performed. For OSAHS patients with dry eye syndrome (DES) who underwent uvulopalatopharyngoplasty for improving AHI, the conditions of the ocular surface and MG were compared before surgery and 3 months after surgery. Only the data of the right eyes were analyzed. Results There were no significantly different in the OSDI score, tear meniscus height (TMH), or loss ratio of the lower eyelid (LRLE) among these groups. The first non-invasive tear film breakup time (fNIBUT), average non-invasive tear film breakup time (avNIBUT), bulbar redness index (BRI), lipid layer grading (LLG), CFS, plugged orifices and distortion in MG, the loss ratio of upper eyelid (LRUE), and the incidence of DES, floppy eyelid syndrome (FES) and meibomian gland dysfunction (MGD) showed significant differences between Groups A and C (p = 0.015, p = 0.018, p < 0.001, p = 0.022, p = 0.036, p = 0.007, p = 0.019, p = 0.017, p = 0.045, p = 0.013, and p = 0.029, respectively). The SIT in the Group A was significantly higher than in Group B (p = 0.025) and in Group C (p < 0.001). In the correlation analyses, the fNIBUT, avNIBUT, SIT and LLG had negative correlations with the AHI (p = 0.013, p = 0.010, p = 0.003, p < 0.001, and p = 0.006, respectively). The BRI, CFS and LRUE were positively correlated with the AHI (p = 0.006, p = 0.007, and p = 0.046, respectively). Three months after surgery, there were no significant differences in the ocular surface or MG. Conclusion Patients with severe OSAHS have poor stability of tear film and are prone to lipid-deficient dry eye as a result of the loss of meibomian gland. By improving the AHI, the ocular surface damage of OSAHS patients cannot be reversed in a short time.
Collapse
Affiliation(s)
- Shaohua Liu
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| | - Shisheng Li
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Mengmeng Li
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Shiying Zeng
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Baihua Chen
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| | - Liwei Zhang
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| |
Collapse
|
17
|
APAP, BPAP, CPAP, and New Modes of Positive Airway Pressure Therapy. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1384:297-330. [PMID: 36217092 DOI: 10.1007/978-3-031-06413-5_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Positive airway pressure (PAP) is the primary treatment of sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. Just as clinicians use pharmacological mechanism of action and pharmacokinetic data to optimize medication therapy for an individual, understanding how PAP works and choosing the right mode and device are critical to optimizing therapy in an individual patient. The first section of this chapter will describe the technology inside PAP devices that is essential for understanding the algorithms used to control the airflow and pressure. The second section will review how different comfort settings including ramp and expiratory pressure relief and modes of PAP therapy including continuous positive airway pressure (CPAP), autotitrating CPAP, bilevel positive airway pressure, adaptive servoventilation, and volume-assured pressure support control the airflow and pressure. Proprietary algorithms from several different manufacturers are described. This chapter derives its descriptions of algorithms from multiple sources including literature review, manufacture publications and websites, patents, and peer-reviewed device comparisons and from personal communication with manufacturer representatives. Clinical considerations related to the technological aspects of the different algorithms and features will be reviewed.
Collapse
|
18
|
Abstract
Obstructive sleep apnea (OSA) is a disease that results from loss of upper airway muscle tone leading to upper airway collapse during sleep in anatomically susceptible persons, leading to recurrent periods of hypoventilation, hypoxia, and arousals from sleep. Significant clinical consequences of the disorder cover a wide spectrum and include daytime hypersomnolence, neurocognitive dysfunction, cardiovascular disease, metabolic dysfunction, respiratory failure, and pulmonary hypertension. With escalating rates of obesity a major risk factor for OSA, the public health burden from OSA and its sequalae are expected to increase, as well. In this chapter, we review the mechanisms responsible for the development of OSA and associated neurocognitive and cardiometabolic comorbidities. Emphasis is placed on the neural control of the striated muscles that control the pharyngeal passages, especially regulation of hypoglossal motoneuron activity throughout the sleep/wake cycle, the neurocognitive complications of OSA, and the therapeutic options available to treat OSA including recent pharmacotherapeutic developments.
Collapse
Affiliation(s)
- Luu V Pham
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, United States.
| | - Jonathan Jun
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, United States
| | - Vsevolod Y Polotsky
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, United States
| |
Collapse
|
19
|
Baillieul S, Dekkers M, Brill AK, Schmidt MH, Detante O, Pépin JL, Tamisier R, Bassetti CLA. Sleep apnoea and ischaemic stroke: current knowledge and future directions. Lancet Neurol 2021; 21:78-88. [PMID: 34942140 DOI: 10.1016/s1474-4422(21)00321-5] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/31/2021] [Accepted: 09/07/2021] [Indexed: 12/11/2022]
Abstract
Sleep apnoea, one of the most common chronic diseases, is a risk factor for ischaemic stroke, stroke recurrence, and poor functional recovery after stroke. More than half of stroke survivors present with sleep apnoea during the acute phase after stroke, with obstructive sleep apnoea being the most common subtype. Following a stroke, sleep apnoea frequency and severity might decrease over time, but moderate to severe sleep apnoea is nevertheless present in up to a third of patients in the chronic phase after an ischaemic stroke. Over the past few decades evidence suggests that treatment for sleep apnoea is feasible during the acute phase of stroke and might favourably affect recovery and long-term outcomes. Nevertheless, sleep apnoea still remains underdiagnosed and untreated in many cases, due to challenges in the detection and prediction of post-stroke sleep apnoea, uncertainty as to the optimal timing for its diagnosis, and a scarcity of clear treatment guidelines (ie, uncertainty on when to treat and the optimal treatment strategy). Moreover, the pathophysiology of sleep apnoea associated with stroke, the proportion of stroke survivors with obstructive and central sleep apnoea, and the temporal evolution of sleep apnoea subtypes following stroke remain to be clarified. To address these shortcomings, the management of sleep apnoea associated with stroke should be integrated into a multidisciplinary diagnostic, treatment, and follow-up strategy.
Collapse
Affiliation(s)
- Sébastien Baillieul
- Department of Neurology, Inselspital, University Hospital, Bern, Switzerland; Service Universitaire de Pneumologie Physiologie, Grenoble Alpes University Hospital, Grenoble, France; Inserm U1300, Grenoble Institute of Neurosciences, Université Grenoble Alpes, Grenoble, France
| | - Martijn Dekkers
- Department of Neurology, Inselspital, University Hospital, Bern, Switzerland
| | - Anne-Kathrin Brill
- Department of Pulmonary Medicine, Inselspital, University Hospital, Bern, Switzerland
| | - Markus H Schmidt
- Department of Neurology, Inselspital, University Hospital, Bern, Switzerland; Ohio Sleep Medicine Institute, Dublin, OH, USA
| | - Olivier Detante
- Stroke Unit, Neurology Department, Grenoble Alpes University Hospital, Grenoble, France; Inserm U1216, Grenoble Institute of Neurosciences, Université Grenoble Alpes, Grenoble, France
| | - Jean-Louis Pépin
- Service Universitaire de Pneumologie Physiologie, Grenoble Alpes University Hospital, Grenoble, France; Inserm U1300, Grenoble Institute of Neurosciences, Université Grenoble Alpes, Grenoble, France
| | - Renaud Tamisier
- Service Universitaire de Pneumologie Physiologie, Grenoble Alpes University Hospital, Grenoble, France; Inserm U1300, Grenoble Institute of Neurosciences, Université Grenoble Alpes, Grenoble, France
| | | |
Collapse
|
20
|
Ni YN, Thomas RJ. A longitudinal study of the accuracy of positive pressure therapy machine-detected apnea-hypopnea events. J Clin Sleep Med 2021; 18:1121-1134. [PMID: 34886948 DOI: 10.5664/jcsm.9814] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
STUDY OBJECTIVES During positive airway pressure (PAP) therapy for sleep apnea syndromes, the machine detected respiratory event index (REIFLOW) is an important method for clinicians to evaluate the beneficial effects of PAP. There are concerns about the accuracy of this detection, which also confounds a related question-how common and severe are residual events on PAP. METHODS Subjects with OSA who underwent a split night polysomnography were recruited prospectively. Those treated with PAP and tracked by the EncoreAnywhere system were analyzed. The ones who stopped PAP within one month were excluded for this analysis. Compliance, therapy data and waveform data were analyzed. Machine detected versus manually scored events were compared at the 1st, 3rd, 6th and 12th month from PAP initiation. Logistic regression was used to determine factors associated with a high REIFLOW difference. RESULTS One hundred and seventy-nine patients with a mean age 59.06 ± 13.97 years old, median body mass index 33.60 (29.75-38.75) kg/m2, and median baseline AHI 46.30 (31.50-65.90) times/hour were included. The difference between the machine detected REIFLOW and manually scored REIFLOW was 10.72 ±8.43 in the first month and remained stable for up to 12 months. Male sex and large leak ≥ 1.5% were more frequent in patients who had an REIFLOW difference of ≥ 5 / hour of use. A titration arousal index ≥ 15/ hour of sleep, and higher ratio of unstable to stable breathing were also associated with an REIFLOW difference ≥ 5 times/hour of use. CONCLUSIONS There is a substantial and sustained difference between manual and automated event estimates during PAP therapy, and some associated factors were identified.
Collapse
Affiliation(s)
- Yue-Nan Ni
- Department of Respiratory, Critical Care and Sleep Medicine, West China School of Medicine and West China Hospital, Sichuan University, China
| | - Robert Joseph Thomas
- Division of Pulmonary, Critical Care and Sleep Medicine, Beth Israel Deaconess Medical Center, Boston, MA
| |
Collapse
|
21
|
Morgenthaler TI. Large telemonitoring databases: the good, the bad, and the useful. J Clin Sleep Med 2021; 17:2349-2350. [PMID: 34669572 DOI: 10.5664/jcsm.9718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
22
|
Malhotra A, Benjafield AV, Cistulli PA, Li J, Woehrle H, Armitstead J, Sterling KL, Nunez CM, Pépin JL. Characterizing respiratory parameters, settings, and adherence in real-world patients using adaptive servo ventilation therapy: big data analysis. J Clin Sleep Med 2021; 17:2355-2362. [PMID: 34170238 PMCID: PMC8726358 DOI: 10.5664/jcsm.9430] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 05/10/2021] [Accepted: 05/13/2021] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES There is minimal guidance around how to optimize inspiratory positive airway pressure (IPAP) levels during use of adaptive servo ventilation (ASV) in clinical practice. This real-world data analysis investigated the effects of IPAP and minimum pressure support settings on respiratory parameters and adherence in ASV-treated patients. METHODS A United States-based telemonitoring database was queried for patients starting ASV between August 1, 2014 and November 30, 2019. Patients meeting the following criteria were included: United States-based patients aged ≥ 18 years; AirCurve 10 device (ResMed); and ≥ 1 session with usage of ≥ 1 hour in the first 90 days. Key outcomes were mask leak and residual apnea-hypopnea index at different IPAP settings, adherence and therapy termination rates, and respiratory parameters at different minimum pressure support settings. RESULTS There were 63,996 patients included. Higher IPAP was associated with increased residual apnea-hypopnea index and mask leak but did not impact device usage per session (average > 6 h/day at all IPAP settings; 6.7 h/day at 95th percentile IPAP 25 cm H2O). There were no clinically relevant differences in respiratory rate, minute ventilation, leak, and residual apnea-hypopnea index across all possible minimum pressure support settings. Patients with a higher 95th percentile IPAP or with minimum pressure support of 3 cm H2O were most likely to remain on ASV therapy at 1 year. CONCLUSIONS Our findings showed robust levels of longer-term adherence to ASV therapy in a large group of real-world patients. There were no clinically important differences in respiratory parameters across a range of pressure and pressure support settings. Future work should focus on the different phenotypes of patients using ASV therapy. CITATION Malhotra A, Benjafield AV, Cistulli PA, et al. Characterizing respiratory parameters, settings, and adherence in real-world patients using adaptive servo ventilation therapy: big data analysis. J Clin Sleep Med. 2021;17(12):2355-2362.
Collapse
Affiliation(s)
- Atul Malhotra
- University of California San Diego, La Jolla, California
| | | | - Peter A. Cistulli
- Charles Perkins Centre, Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | | | | | | | | | | | - Jean-Louis Pépin
- Institut National de la Santé et de la Recherche Médicale, HP2 Laboratory (Hypoxia: Pathophysiology), Grenoble Alpes University, Grenoble, France
| | - on behalf of the medXcloud group
- University of California San Diego, La Jolla, California
- ResMed Science Center, Sydney, Australia
- Charles Perkins Centre, Faculty of Medicine and Health, University of Sydney, Sydney, Australia
- ResMed Science Center, Singapore
- Sleep and Ventilation Center Blaubeuren, Ulm, Germany
- ResMed Science Center, San Diego, California
- Institut National de la Santé et de la Recherche Médicale, HP2 Laboratory (Hypoxia: Pathophysiology), Grenoble Alpes University, Grenoble, France
| |
Collapse
|
23
|
Midelet A, Bailly S, Tamisier R, Borel JC, Baillieul S, Le Hy R, Schaeffer MC, Pépin JL. Hidden Markov model segmentation to demarcate trajectories of residual apnoea-hypopnoea index in CPAP-treated sleep apnoea patients to personalize follow-up and prevent treatment failure. EPMA J 2021; 12:535-544. [PMID: 34956425 PMCID: PMC8648940 DOI: 10.1007/s13167-021-00264-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/02/2021] [Indexed: 12/26/2022]
Abstract
BACKGROUND Continuous positive airway pressure (CPAP), the reference treatment for obstructive sleep apnoea (OSA), is used by millions of individuals worldwide with remote telemonitoring providing daily information on CPAP usage and efficacy, a currently underused resource. Here, we aimed to implement data science methods to provide tools for personalizing follow-up and preventing treatment failure. METHODS We analysed telemonitoring data from adults prescribed CPAP treatment. Our primary objective was to use Hidden Markov models (HMMs) to identify the underlying state of treatment efficacy and enable early detection of deterioration. Secondary goals were to identify clusters of rAHI trajectories which need distinct therapeutic strategies. RESULTS From telemonitoring records of 2860 CPAP-treated patients (age: 66.31 ± 12.92 years, 69.9% male), HMM estimated three states differing in variability within a given state and probability of shifting from one state to another. The daily inferred state informs on the need for a personalized action, while the sequence of states is a predictive indicator of treatment failure. Six clusters of rAHI trajectories were identified ranging from well-controlled patients (cluster 0: 669 (23%); mean rAHI 0.58 ± 0.59 events/h) to the most unstable (cluster 5: 470 (16%); mean rAHI 9.62 ± 5.62 events/h). CPAP adherence was 30 min higher in cluster 0 compared to clusters 4 and 5 (P value < 0.01). CONCLUSION This new approach based on HMM might constitute the backbone for deployment of patient-centred CPAP management improving the personalized interpretation of telemonitoring data, identifying individuals for targeted therapy and preventing treatment failure or abandonment. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s13167-021-00264-z.
Collapse
Affiliation(s)
- Alphanie Midelet
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- Probayes, Montbonnot-Saint-Martin, France
| | - Sébastien Bailly
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | - Renaud Tamisier
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | - Jean-Christian Borel
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- AGIR à dom. HomeCare Charity, 38240 Meylan, France
| | - Sébastien Baillieul
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| | | | | | - Jean-Louis Pépin
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, 38000 Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, 38000 Grenoble, France
| |
Collapse
|
24
|
Baillieul S, Bailly S, Detante O, Alexandre S, Destors M, Clin R, Dole M, Pépin JL, Tamisier R. Sleep-disordered breathing and ventilatory chemosensitivity in first ischaemic stroke patients: a prospective cohort study. Thorax 2021; 77:1006-1014. [PMID: 34772798 DOI: 10.1136/thoraxjnl-2021-218003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 10/20/2021] [Indexed: 11/04/2022]
Abstract
RATIONALE Sleep-disordered breathing (SDB) is highly prevalent after stroke. The clinical and ventilatory chemosensitivity characteristics of SDB, namely obstructive, central and coexisting obstructive and central sleep apnoea (coexisting sleep apnoea) following stroke are poorly described. OBJECTIVE To determine the respective clinical and ventilatory chemosensitivity characteristics of SDB at least 3 months after a first ischaemic stroke. METHODS Cross-sectional analysis of a prospective, monocentric cohort conducted in a university hospital. 380 consecutive stroke or transient ischaemic attack patients were screened between December 2016 and December 2019. MEASUREMENTS AND MAIN RESULTS Full-night polysomnography, and hypercapnic ventilatory response were performed at a median (Q1; Q3) time from stroke onset of 134.5 (97.0; 227.3) days. 185 first-time stroke patients were included in the analysis. 94 (50.8%) patients presented no or mild SDB (Apnoea-Hypopnoea Index <15 events/hour of sleep) and 91 (49.2%) moderate to severe SDB, of which 52 (57.1%) presented obstructive sleep apnoea and 39 (42.9%) coexisting or central sleep apnoea. Obstructive sleep apnoea patients significantly differed regarding their clinical presentation from patients with no or mild SDB, whereas there was no difference with coexisting and central sleep apnoea patients. The latter presented a higher frequency of cerebellar lesions along with a heightened hypercapnic ventilatory response compared with no or mild SDB patients. CONCLUSION SDB in first-time stroke patients differ in their presentation by their respective clinical traits and ventilatory chemosensitivity characteristics. The heightened hypercapnic ventilatory response in coexisting and central sleep apnoea stroke patients may orientate them to specific ventilatory support.
Collapse
Affiliation(s)
- Sébastien Baillieul
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Sébastien Bailly
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Olivier Detante
- Stroke Unit, Neurology Department, Grenoble Alpes University Hospital, Grenoble, France.,Grenoble Institute of Neurosciences, Inserm U1216, Université Grenoble Alpes, Grenoble, France
| | - Sarah Alexandre
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Marie Destors
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Rita Clin
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Marjorie Dole
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Jean-Louis Pépin
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| | - Renaud Tamisier
- Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France
| |
Collapse
|
25
|
Guerrero G, Le Rolle V, Loiodice C, Amblard A, Pepin JL, Hernandez A. Modeling patient-specific desaturation patterns in sleep apnea. IEEE Trans Biomed Eng 2021; 69:1502-1511. [PMID: 34665719 DOI: 10.1109/tbme.2021.3121170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE The physiological mechanisms involved in cardio-respiratory responses to sleep apnea events are not yet fully elucidated. A model-based approach is proposed to analyse the acute desaturation response to obstructive apneas. METHODS An integrated model of cardio-respiratory interactions was proposed and parameters were identified, using an evolutionary algorithm, on a database composed of 107 obstructive apneas acquired from 10 patients (HYPNOS clinical study). Unsupervised clustering was applied to the identified parameters in order to characterize the phenotype of each response to obstructive apneas. RESULTS A close match was observed between simulated oxygen saturation (SaO2) and experimental SaO2 in all identifications (median RMSE = 1.3892%). Two clusters of parameters, associated with different dynamics related to sleep apnea and periodic breathing were obtained. CONCLUSION AND SIGNIFICANCE The proposed patient and event-specific model-based analysis provides understanding on specific desaturation patterns, consequent to apnea events, with potential applications for personalized diagnosis and treatment.
Collapse
|
26
|
The Importance of Mask Selection on Continuous Positive Airway Pressure Outcomes for Obstructive Sleep Apnea. An Official American Thoracic Society Workshop Report. Ann Am Thorac Soc 2021; 17:1177-1185. [PMID: 33000960 PMCID: PMC7640631 DOI: 10.1513/annalsats.202007-864st] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Continuous positive airway pressure (CPAP) remains the major treatment option for obstructive sleep apnea (OSA). The American Thoracic Society organized a workshop to discuss the importance of mask selection for OSA treatment with CPAP. In this workshop report, we summarize available evidence about the breathing route during nasal and oronasal CPAP and the importance of nasal symptoms for CPAP outcomes. We explore the mechanisms of air leaks during CPAP treatment and possible alternatives for leak control. The impact of nasal and oronasal CPAP on adherence, residual apnea-hypopnea index, unintentional leaks, and pressure requirements are also compared. Finally, recommendations for patient and partner involvement in mask selection are presented, and future directions to promote personalized mask selection are discussed.
Collapse
|
27
|
Optimal Noninvasive Medicare Access Promotion: Patients with Central Sleep Apnea A Technical Expert Panel Report from the American College of Chest Physicians, the American Association for Respiratory Care, the American Academy of Sleep Medicine, and the American Thoracic Society. Chest 2021; 160:e419-e425. [PMID: 34339687 DOI: 10.1016/j.chest.2021.07.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 07/10/2021] [Accepted: 07/18/2021] [Indexed: 11/20/2022] Open
Abstract
This document summarizes suggestions of the central sleep apnea (CSA) technical expert panel (TEP) working group. This paper shares our vision for bringing the right device to the right patient at the right time. For patients with CSA, current coverage criteria do not align with guideline treatment recommendations. For example, continuous positive airway pressure (CPAP) and oxygen therapy are recommended but not covered for CSA. On the other hand, BPAP without a backup rate may be a covered therapy for OSA, but it may worsen CSA. Narrow coverage criteria that require near elimination of obstructive breathing events on CPAP or bilevel positive airway pressure in the spontaneous mode , even if at poorly tolerated pressure levels, may preclude therapy with BPAP with backup rate or adaptive servoventilation (ASV), even when those devices provide demonstrably better therapy. CSA is a dynamic disorder that may require different treatments over time, sometimes switching from one device to another, for example from BPAP with backup rate to an ASV with automatic end expiratory pressure adjustments, which may not be covered. To address these challenges we suggest several changes to the coverage determinations, including 1) a single simplified initial and continuing coverage definition of CSA that aligns with obstructive sleep apnea, 2) removal of hypoventilation terminology from coverage criteria for CSA, 3) all effective therapies for CSA should be covered, including oxygen and all PAP devices with or without backup rates or servo-mechanisms, and 4) patients shown to have a suboptimal response to one PAP device should be allowed to add oxygen or change to another PAP device with different capabilities if shown to be effective with testing.
Collapse
|
28
|
Rosenberg R, Schweitzer PK, Steier J, Pepin JL. Residual excessive daytime sleepiness in patients treated for obstructive sleep apnea: guidance for assessment, diagnosis, and management. Postgrad Med 2021; 133:772-783. [PMID: 34292843 DOI: 10.1080/00325481.2021.1948305] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Excessive daytime sleepiness (EDS) affects approximately half of patients with obstructive sleep apnea (OSA) and can persist in some despite normalization of breathing, oxygenation, and sleep quality with primary OSA therapy, such as continuous positive airway pressure (CPAP). EDS is often overlooked and under discussed in the primary care setting and in the follow-up of CPAP-treated patients due to difficult assessment of such a multi-dimensional symptom. This review aims to provide suggestions for procedures that can be implemented into routine clinical practice to identify, evaluate, and manage EDS in patients treated for OSA, including how to appropriately use various self-report and objective assessments along the clinical pathway and options for pharmacotherapy. In addition, examples of when it is appropriate to refer a patient to a sleep specialist for evaluation are discussed.
Collapse
Affiliation(s)
| | - Paula K Schweitzer
- Sleep Medicine and Research Center, St. Luke's Hospital, Chesterfield, MO, USA
| | - Joerg Steier
- Respiratory and Sleep Medicine, Faculty of Life Sciences and Medicine, King's College, London, England
| | - Jean-Louis Pepin
- HP2 Laboratory, Inserm U1042, Grenoble Alpes University, Research Department, Grenoble, France
| |
Collapse
|
29
|
Berger M, Solelhac G, Horvath C, Heinzer R, Brill AK. Treatment-emergent central sleep apnea associated with non-positive airway pressure therapies in obstructive sleep apnea patients: A systematic review. Sleep Med Rev 2021; 58:101513. [PMID: 34166994 DOI: 10.1016/j.smrv.2021.101513] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 04/26/2021] [Accepted: 05/28/2021] [Indexed: 12/29/2022]
Abstract
This systematic review summarizes the prevalence of treatment-emergent central sleep apnea (TECSA) occurring with therapies other than positive airway pressure (PAP) for the management of obstructive sleep apnea (OSA). We describe its natural course as well as the proposed underlying pathophysiological mechanisms and the clinical management of affected patients. A systematic search of PubMed, Embase, Web of science, and the Cochrane Library was performed until June 2020. Eighteen studies (n = 284 patients) were included. TECSA was observed in 31 patients with the use of four different medical devices (mandibular advancement device, hypoglossal nerve stimulation, tongue stabilizing device and nasal expiratory PAP) and after three different types of surgical treatments (tracheostomy, maxillofacial surgery and oro-nasal surgery). Due to the paucity of data available, it was not possible to establish a clear prevalence rate of TECSA for each alternative treatment. After the initiation of non-PAP treatments, a systematic reassessment of the treatment efficacy with follow-up sleep studies will be helpful to identify TECSA. A spontaneous resolution over time was described as well as a persistence of TECSA. In this case, treatment should focus on patients' specific underlying pathophysiology. Overall, the limited current literature suggests that this phenomenon is rare (<4%).
Collapse
Affiliation(s)
- Mathieu Berger
- Center for Investigation and Research in Sleep (CIRS), Lausanne University Hospital (CHUV), University of Lausanne, Lausanne, Switzerland.
| | - Geoffroy Solelhac
- Center for Investigation and Research in Sleep (CIRS), Lausanne University Hospital (CHUV), University of Lausanne, Lausanne, Switzerland
| | - Christian Horvath
- Department of Pulmonary Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Raphael Heinzer
- Center for Investigation and Research in Sleep (CIRS), Lausanne University Hospital (CHUV), University of Lausanne, Lausanne, Switzerland
| | - Anne-Kathrin Brill
- Department of Pulmonary Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| |
Collapse
|
30
|
Abstract
Treatment-emergent central sleep apnea (TECSA) is a specific form of sleep-disordered breathing, characterized by the emergence or persistence of central apneas during treatment for obstructive sleep apnea. The purpose of this review was to summarize the definition, epidemiology, potential mechanisms, clinical characteristics, and treatment of TECSA. We searched for relevant articles up to January 31, 2020, in the PubMed database. The prevalence of TECSA varied widely in different studies. The potential mechanisms leading to TECSA included ventilatory control instability, low arousal threshold, activation of lung stretch receptors, and prolonged circulation time. TECSA may be a self-limited disorder in some patients and could be resolved spontaneously over time with ongoing treatment of continuous positive airway pressure (CPAP). However, central apneas persist even with the regular CPAP therapy in some patients, and new treatment approaches such as adaptive servo-ventilation may be necessary. We concluded that several questions regarding TECSA remain, despite the findings of many studies, and it is necessary to carry out large surveys with basic scientific design and clinical trials for TECSA to clarify these irregularities. Further, it will be vital to evaluate the baseline demographic and polysomnographic data of TECSA patients more carefully and comprehensively.
Collapse
|
31
|
Orr JE, Ayappa I, Eckert DJ, Feldman JL, Jackson CL, Javaheri S, Khayat RN, Martin JL, Mehra R, Naughton MT, Randerath WJ, Sands SA, Somers VK, Badr MS. Research Priorities for Patients with Heart Failure and Central Sleep Apnea. An Official American Thoracic Society Research Statement. Am J Respir Crit Care Med 2021; 203:e11-e24. [PMID: 33719931 PMCID: PMC7958519 DOI: 10.1164/rccm.202101-0190st] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Background: Central sleep apnea (CSA) is common among patients with heart failure and has been strongly linked to adverse outcomes. However, progress toward improving outcomes for such patients has been limited. The purpose of this official statement from the American Thoracic Society is to identify key areas to prioritize for future research regarding CSA in heart failure. Methods: An international multidisciplinary group with expertise in sleep medicine, pulmonary medicine, heart failure, clinical research, and health outcomes was convened. The group met at the American Thoracic Society 2019 International Conference to determine research priority areas. A statement summarizing the findings of the group was subsequently authored using input from all members. Results: The workgroup identified 11 specific research priorities in several key areas: 1) control of breathing and pathophysiology leading to CSA, 2) variability across individuals and over time, 3) techniques to examine CSA pathogenesis and outcomes, 4) impact of device and pharmacological treatment, and 5) implementing CSA treatment for all individuals Conclusions: Advancing care for patients with CSA in the context of heart failure will require progress in the arenas of translational (basic through clinical), epidemiological, and patient-centered outcome research. Given the increasing prevalence of heart failure and its associated substantial burden to individuals, society, and the healthcare system, targeted research to improve knowledge of CSA pathogenesis and treatment is a priority.
Collapse
|
32
|
Lim T, Lim SH, Koo BM, Hwang J, Oh JH, Rhee J, Park P. Effect of healthcare benefits on short-term adherence of positive airway pressure therapy. CLINICAL RESPIRATORY JOURNAL 2021; 15:735-740. [PMID: 33721381 DOI: 10.1111/crj.13355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 03/10/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE The objective of this study was to assess the impact of healthcare benefits on adherence to positive airway pressure (PAP) therapy in obstructive sleep apnea (OSA) patients. METHODS Medical records of OSA patients at the Veterans Health Service Medical Center were retrospectively reviewed. OSA patients were assigned to two groups as the date of prescribing PAP: after (=Group A) and before (=Group B) July 1, 2018 when PAP therapy starts to be included in healthcare insurance coverage for OSA patients in South Korea. PAP adherence was compared over a 3-month period between the two groups; subjective improvement after therapy was evaluated using the Epworth Sleepiness Scale (ESS) and Pittsburgh Sleep Quality Index scores. In addition, we evaluated a number of OSA patients who chose to start PAP therapy without healthcare benefit (from July 2018 to December 2018). RESULTS Each of the 50 patients in the Group A and B exhibited PAP adherence rates of 82% and 26%, respectively (P < .001). Age did not affect PAP adherence in the Group A. The mean apnea-hypopnea index (from 36.7 to 1.34, P < .001) and ESS (from 7.6 to 5.6, P = .004) scores of patients in the Group A had significantly improved within the first three months. Twenty-three (23 out of 334, 6.9%) OSA patients did not have any healthcare insurance, but they medically needed PAP therapy. However, only one of the 23 patients began PAP treatment. CONCLUSION Short-term PAP adherence significantly improved after PAP therapy was included in healthcare insurance coverage.
Collapse
Affiliation(s)
- Taehun Lim
- Department of Otorhinolaryngology-Head and Neck Surgery, National Police Hospital, Seoul, South Korea
| | - Sung Hwan Lim
- Department of Otorhinolaryngology-Head and Neck Surgery, Veterans Health Service Medical Center, Seoul, South Korea
| | - Beom Mo Koo
- Department of Otorhinolaryngology-Head and Neck Surgery, Veterans Health Service Medical Center, Seoul, South Korea
| | - Junho Hwang
- Department of Otorhinolaryngology-Head and Neck Surgery, National Police Hospital, Seoul, South Korea
| | - Joo Hyung Oh
- Department of Otorhinolaryngology-Head and Neck Surgery, National Police Hospital, Seoul, South Korea
| | - Jihye Rhee
- Department of Otorhinolaryngology-Head and Neck Surgery, Veterans Health Service Medical Center, Seoul, South Korea
| | - Pona Park
- Department of Otorhinolaryngology-Head and Neck Surgery, National Police Hospital, Seoul, South Korea
| |
Collapse
|
33
|
Midelet A, Borel JC, Tamisier R, Le Hy R, Schaeffer MC, Daabek N, Pépin JL, Bailly S. Apnea-hypopnea index supplied by CPAP devices: time for standardization? Sleep Med 2021; 81:120-122. [PMID: 33667996 DOI: 10.1016/j.sleep.2021.02.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/05/2021] [Accepted: 02/08/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND/OBJECTIVE For obstructive sleep apnea (OSA) patients on continuous positive airway pressure (CPAP) treatment, the apnea-hypopnea index (AHI) is a key measure of treatment efficacy. However, the residual AHI is CPAP brand specific. Here, we studied changes in residual AHI in patients who used two different brands over their treatment history. PATIENTS/METHODS Using our CPAP telemonitoring database of 3102 patients, we compared the residual AHI of 69 patients before and after change in their CPAP device. RESULTS A paired Wilcoxon signed-rank test revealed a significant difference between brands in the reported AHI, which might be clinically misleading. CONCLUSIONS These findings suggest that physicians should be alerted to the differences between brands and learned societies should push for standardization of AHI reporting.
Collapse
Affiliation(s)
- Alphanie Midelet
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France; Probayes, Montbonnot-Saint-Martin, France.
| | - Jean-Christian Borel
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France; AGIR à dom. Home-Care Charity, Meylan, France
| | - Renaud Tamisier
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France
| | | | | | - Najeh Daabek
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France; AGIR à dom. Home-Care Charity, Meylan, France
| | - Jean-Louis Pépin
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France
| | - Sébastien Bailly
- Laboratoire Hypoxie et Physiopathologie cardiovasculaire et respiratoire (HP2), INSERM U1042, Grenoble Alpes University, Grenoble, France
| |
Collapse
|
34
|
Selim B, Ramar K. Sleep-Related Breathing Disorders: When CPAP Is Not Enough. Neurotherapeutics 2021; 18:81-90. [PMID: 33150546 PMCID: PMC8116389 DOI: 10.1007/s13311-020-00955-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/19/2020] [Indexed: 02/07/2023] Open
Abstract
Three decades ago, continuous positive airway pressure (CPAP) was introduced to treat obstructive sleep apnea (OSA). Shortly after, bilevel positive airway pressure devices (BPAP) that independently adjusted inspiratory and expiratory positive airway pressure were developed to treat complex sleep-related breathing disorders unresponsive to CPAP. Based on the bilevel positive airway pressure platform (hardware) governed by propriety algorithms (software), advanced modes of noninvasive ventilation (NIV) were developed to address complex cardiorespiratory pathophysiology beyond OSA. This review summarizes key aspects of different bilevel PAP therapies (BPAP with/without backup rate, adaptive servoventilation, and volume-assured pressure support) to treat common sleep-related hypoventilation disorders, treatment-emergent central sleep apnea, and central sleep apnea syndromes.
Collapse
Affiliation(s)
- Bernardo Selim
- Pulmonary and Critical Care Division, Center for Sleep Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
| | - Kannan Ramar
- Pulmonary and Critical Care Division, Center for Sleep Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| |
Collapse
|
35
|
Patterns of adaptive servo-ventilation settings in a real-life multicenter study: pay attention to volume! : Adaptive servo-ventilation settings in real-life conditions. Respir Res 2020; 21:243. [PMID: 32957983 PMCID: PMC7507637 DOI: 10.1186/s12931-020-01509-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 09/13/2020] [Indexed: 01/03/2023] Open
Abstract
Backgrounds To explain the excess cardiovascular mortality observed in the SERVE-HF study, it was hypothesized that the high-pressure ASV default settings used lead to inappropriate ventilation, cascading negative consequences (i.e. not only pro-arrythmogenic effects through metabolic/electrolyte abnormalities, but also lower cardiac output). The aims of this study are: i) to describe ASV-settings for long-term ASV-populations in real-life conditions; ii) to describe the associated minute-ventilations (MV) and therapeutic pressures for servo-controlled-flow versus servo-controlled-volume devices (ASV-F Philips®-devices versus ASV-V ResMed®-devices). Methods The OTRLASV-study is a cross-sectional, 5-centre study including patients who underwent ASV-treatment for at least 1 year. The eight participating clinicians were free to adjust ASV settings, which were compared among i) initial diagnosed sleep-disordered-breathing (SBD) groups (Obstructive-Sleep-Apnea (OSA), Central-Sleep-Apnea (CSA), Treatment-Emergent-Central-Sleep-Apnea (TECSA)), and ii) unsupervised groups (k-means clusters). To generate these clusters, baseline and follow-up variables were used (age, sex, body mass index (BMI), initial diagnosed Obstructive-Apnea-Index, initial diagnosed Central-Apnea-Index, Continuous-Positive-Airway-Pressure used before ASV treatment, presence of cardiopathy, and presence of a reduced left-ventricular-ejection-fraction (LVEF)). ASV-data were collected using the manufacturer’s software for 6 months. Results One hundred seventy-seven patients (87.57% male) were analysed with a median (IQ25–75) initial Apnea-Hypopnea-Index of 50 (38–62)/h, an ASV-treatment duration of 2.88 (1.76–4.96) years, 61.58% treated with an ASV-V. SDB groups did not differ in ASV settings, MV or therapeutic pressures. In contrast, the five generated k-means clusters did (generally described as follows: (C1) male-TECSA-cardiopathy, (C2) male-mostly-CSA-cardiopathy, (C3) male-mostly-TECSA-no cardiopathy, (C4) female-mostly-elevated BMI-TECSA-cardiopathy, (C5) male-mostly-OSA-low-LVEF). Of note, the male-mostly-OSA-low-LVEF-cluster-5 had significantly lower fixed end-expiratory-airway-pressure (EPAP) settings versus C1 (p = 0.029) and C4 (p = 0.007). Auto-EPAP usage was higher in the male-mostly-TECSA-no cardiopathy-cluster-3 versus C1 (p = 0.006) and C2 (p < 0.001). MV differences between ASV-F (p = 0.002) and ASV-V (p < 0.001) were not homogenously distributed across clusters, suggesting specific cluster and ASV-algorithm interactions. Individual ASV-data suggest that the hyperventilation risk is not related to the cluster nor the ASV-monitoring type. Conclusions Real-life ASV settings are associated with combinations of baseline and follow-up variables wherein cardiological variables remain clinically meaningful. At the patient level, a hyperventilation risk exists regardless of cluster or ASV-monitoring type, spotlighting a future role of MV-telemonitoring in the interest of patient-safety. Trial registration The OTRLASV study was registered on ClinicalTrials.gov (Identifier: NCT02429986). 1 April 2015.
Collapse
|
36
|
Digitale respiratorische Schlafmedizin – Teil II: Therapie. SOMNOLOGIE 2020. [DOI: 10.1007/s11818-020-00263-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
37
|
Sunwoo BY, Schmickl CN, Malhotra A. Contemporary Concise Review 2019: Sleep and ventilation. Respirology 2020; 25:552-558. [PMID: 32048407 PMCID: PMC7162714 DOI: 10.1111/resp.13781] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 01/29/2020] [Indexed: 12/30/2022]
Affiliation(s)
- Bernie Y Sunwoo
- Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego (UCSD), La Jolla, CA, USA
| | - Christopher N Schmickl
- Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego (UCSD), La Jolla, CA, USA
| | - Atul Malhotra
- Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego (UCSD), La Jolla, CA, USA
| |
Collapse
|
38
|
Cantero C, Adler D, Pasquina P, Uldry C, Egger B, Prella M, Younossian AB, Poncet A, Soccal-Gasche P, Pepin JL, Janssens JP. Adaptive Servo-Ventilation: A Comprehensive Descriptive Study in the Geneva Lake Area. Front Med (Lausanne) 2020; 7:105. [PMID: 32309284 PMCID: PMC7145945 DOI: 10.3389/fmed.2020.00105] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 03/09/2020] [Indexed: 12/29/2022] Open
Abstract
Background: Use of adaptive servo-ventilation (ASV) has been questioned in patients with central sleep apnea (CSA) and chronic heart failure (CHF). This study aims to detail the present use of ASV in clinical practice. Methods: Descriptive, cross-sectional, multicentric study of patients undergoing long term (≥3 months) ASV in the Cantons of Geneva or Vaud (1,288,378 inhabitants) followed by public or private hospitals, private practitioners and/or home care providers. Results: Patients included (458) were mostly male (392; 85.6%), overweight [BMI (median, IQR): 29 kg/m2 (26; 33)], comorbid, with a median age of 71 years (59–77); 84% had been treated by CPAP before starting ASV. Indications for ASV were: emergent sleep apnea (ESA; 337; 73.6%), central sleep apnea (CSA; 108; 23.6%), obstructive sleep apnea (7; 1.5%), and overlap syndrome (6; 1.3%). Origin of CSA was cardiac (n = 30), neurological (n = 26), idiopathic (n = 28), or drug-related (n = 22). Among CSA cases, 60 (56%) patients had an echocardiography within the preceding 12 months; median left ventricular ejection fraction (LVEF) was 62.5% (54–65); 11 (18%) had a LVEF ≤45%. Average daily use of ASV was [mean (SD)] 368 (140) min; 13% used their device <3:30 h. Based on ventilator software, apnea-hypopnea index was normalized in 94% of subjects with data available (94% of 428). Conclusions: Use of ASV has evolved from its original indication (CSA in CHF) to a heterogeneous predominantly male, aged, comorbid, and overweight population with mainly ESA or CSA. CSA in CHF represented only 6.5% of this population. Compliance and correction of respiratory events were satisfactory. Clinical Trial Registration:www.ClinicalTrials.gov, identifier: NCT04054570.
Collapse
Affiliation(s)
- Chloé Cantero
- Division of Pulmonary Diseases, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Dan Adler
- Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Respiratory Diseases and Pulmonary Rehabilitation Center, Rolle Hospital, Rolle, Switzerland
| | | | - Christophe Uldry
- Respiratory Diseases and Pulmonary Rehabilitation Center, Rolle Hospital, Rolle, Switzerland
| | - Bernard Egger
- Respiratory Diseases and Pulmonary Rehabilitation Center, Rolle Hospital, Rolle, Switzerland
| | - Maura Prella
- Division of Pulmonary Diseases, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Alain Bigin Younossian
- Division of Pulmonary Diseases and Intensive Care, La Tour Hospital, Geneva, Switzerland
| | - Antoine Poncet
- Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Center for Clinical Research and Division of Clinical Epidemiology, Department of Health and Community Medicine, University Hospitals of Geneva (HUG), Geneva, Switzerland
| | - Paola Soccal-Gasche
- Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Respiratory Diseases and Pulmonary Rehabilitation Center, Rolle Hospital, Rolle, Switzerland
| | - Jean-Louis Pepin
- Inserm U1042 Unit, HP2 Laboratory, University Grenoble Alps, Grenoble, France.,EFCR Laboratory, Thorax and Vessels and Vessels, Grenoble Alps University Hospital, Grenoble, France
| | - Jean-Paul Janssens
- Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Respiratory Diseases and Pulmonary Rehabilitation Center, Rolle Hospital, Rolle, Switzerland
| |
Collapse
|
39
|
|
40
|
Update on Persistent Excessive Daytime Sleepiness in OSA. Chest 2020; 158:776-786. [PMID: 32147246 DOI: 10.1016/j.chest.2020.02.036] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 01/31/2020] [Accepted: 02/22/2020] [Indexed: 12/17/2022] Open
Abstract
OSA is a highly prevalent sleep disorder, and subjective excessive daytime sleepiness (EDS) is the cardinal symptom for which many individuals seek medical advice. Positive airway pressure (PAP) devices, first-line treatment for OSA, eliminates EDS in most patients. However, a subset of patients suffers from persistent EDS despite adherence to therapy. Multiple conditions, some reversible, could account for the residual sleepiness and need to be explored, requiring detailed history, review of PAP data from the smart card, and sometimes additional testing. When all known causes of EDS are excluded, in adequately treated subjects, the purported mechanisms could relate to long-term exposure to the OSA-related sleep fragmentation, sleep deprivation, and hypoxic injury to the arousal system, shifts in melatonin secretion, or altered microbiome. Independent of the mechanism, in well-treated OSA, pharmacological therapy with approved drugs can be considered. Modafinil is commonly prescribed to combat residual EDS, but more recently two drugs, solriamfetol, a dual dopamine-norepinephrine reuptake inhibitor, and pitolisant, a histamine H3 receptor inverse agonist, were approved for EDS. Solriamfetol has undergone randomized controlled trials for treatment of EDS associated with both OSA and narcolepsy, exhibiting robust efficacy. Solriamfetol is renally excreted, with no known drug interactions. Pitolisant, which is nonscheduled, has undergone multiple RCTs in narcolepsy, showing improvement in subjective and objective EDS and one OSA trial showing improvement in subjective EDS.
Collapse
|
41
|
Huseini T, McArdle N, Jasper E, Kurmagadda S, Douglas J, King S, Sturdy G, Singh B. The use and effectiveness of adaptive servo ventilation in central sleep apnea: a study of consecutive sleep clinic patients. J Sleep Res 2020; 29:e13016. [PMID: 32087043 DOI: 10.1111/jsr.13016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 12/24/2019] [Accepted: 02/03/2020] [Indexed: 02/03/2023]
Abstract
The use of adaptive servo ventilation to treat central sleep apnea in the clinical setting is incompletely understood and could be under-utilized. We reviewed our experience of adaptive servo ventilation use in patients with central sleep apnea. This study shows the effectiveness of adaptive servo ventilation in treating patients with central sleep apnea, irrespective of a predisposing factor, as assessed during a 4-week treatment trial. Results show that adaptive servo ventilation was effective and superior to continuous positive airway pressure in controlling central sleep apnea and improving symptoms. Only a small proportion of these patients had comorbid heart failure. Early treatment with adaptive servo ventilation may improve long-term adherence to therapy. These findings highlight the utility of adaptive servo ventilation in the management of central sleep apnea.
Collapse
Affiliation(s)
- Taha Huseini
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Nigel McArdle
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.,West Australian Sleep Disorders Research Institute, Nedlands, WA, Australia.,School of Human Sciences, University of Western Australia, Crawley, WA, Australia
| | - Emily Jasper
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Sasya Kurmagadda
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Jane Douglas
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Stuart King
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Gavin Sturdy
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| | - Bhajan Singh
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.,West Australian Sleep Disorders Research Institute, Nedlands, WA, Australia.,School of Human Sciences, University of Western Australia, Crawley, WA, Australia
| |
Collapse
|
42
|
Khemani RG. Value and limitations of real-world data to understand paediatric adherence to positive airway pressure therapy. Lancet Digit Health 2020; 2:e56-e57. [PMID: 33334560 DOI: 10.1016/s2589-7500(19)30237-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 12/09/2019] [Indexed: 06/12/2023]
Affiliation(s)
- Robinder G Khemani
- Children's Hospital Los Angeles, Los Angeles, CA, USA; Keck School of Medicine, University of Southern California, Los Angeles, CA 90027, USA.
| |
Collapse
|
43
|
Zinchuk A, Yaggi HK. Phenotypic Subtypes of OSA: A Challenge and Opportunity for Precision Medicine. Chest 2020; 157:403-420. [PMID: 31539538 PMCID: PMC7005379 DOI: 10.1016/j.chest.2019.09.002] [Citation(s) in RCA: 144] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 08/13/2019] [Accepted: 09/01/2019] [Indexed: 12/21/2022] Open
Abstract
Current strategies for the management of OSA reflect a one-size-fits-all approach. Diagnosis and severity of OSA are based on the apnea-hypopnea index and treatment initiated with CPAP, followed by trials of alternatives (eg, oral appliances) if CPAP "fails." This approach does not consider the heterogeneity of individuals with OSA, reflected by varying risk factors, pathophysiological causes, clinical manifestations, and consequences. Recently, studies using analytic approaches such as cluster analysis have taken advantage of this heterogeneity to identify OSA phenotypes, or subtypes of patients with unique characteristics, that may enable more personalized approaches to prognostication and treatment. Examples include symptom-based subtypes such as "excessively sleepy" and "disturbed sleep" with differing impact of CPAP on symptoms and health-related quality of life. Polysomnographic subtypes, distinguished by respiratory event association with hypoxemia, arousals, or both, exhibit varying risks of cardiovascular disease and response to therapy. This review summarizes the findings from recent cluster analysis studies in sleep apnea and synthesizes common themes to describe the potential role (and limitations) of phenotypic subtypes in precision medicine for OSA. It also highlights future directions, including linking of phenotypes to clinically relevant outcomes, rigorous and transparent assessment of phenotype reproducibility, and need for tools that categorize patients into subtypes, to prospectively validate phenotype-based prognostication and treatment approaches. Finally, we highlight the critical need to include women and more racially/ethnically diverse populations in this area of research if we are to leverage the heterogeneity of OSA to improve patient lives.
Collapse
Affiliation(s)
- Andrey Zinchuk
- Department of Internal Medicine, Section of Pulmonary, Critical Care, and Sleep Medicine, Yale University School of Medicine, New Haven, CT.
| | - Henry K Yaggi
- Department of Internal Medicine, Section of Pulmonary, Critical Care, and Sleep Medicine, Yale University School of Medicine, New Haven, CT; Veterans Affairs Connecticut Health Care System, West Haven, CT
| |
Collapse
|
44
|
Jullian-Desayes I, Joyeux-Faure M, Baillieul S, Guzun R, Tamisier R, Pepin JL. [What prospects for the sleep apnea syndrome and connected health?]. Orthod Fr 2019; 90:435-442. [PMID: 34643529 DOI: 10.1051/orthodfr/2019019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Connected health is a growing field and can be viewed from different perspectives, particularly in sleep apnea syndrome. The purpose of this review is to show how all these aspects of connected health are already used in the management of sleep apnea syndrome (SAS) and its comorbidities. First, it can give patients a better understanding and a better assessment of their health. It also facilitates their healthcare by allowing them a greater role in their care pathway. For healthcare providers, connected health tools make it possible to set up new procedures for diagnosing and monitoring ambulatory patients, and for the making of joint decisions by health professionals and patients. Finally, for researchers, e-health generates massive amounts of data, thus facilitating the acquisition of knowledge in real life situations and the development of new methodologies for clinical studies that are faster, less expensive and just as reliable. All these considerations are already applicable in the field of sleep apnea, both for proposed treatments and for comorbidities management and for the patient's involvement in his/her care pathway.
Collapse
Affiliation(s)
- Ingrid Jullian-Desayes
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| | - Marie Joyeux-Faure
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| | - Sébastien Baillieul
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| | - Rita Guzun
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| | - Renaud Tamisier
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| | - Jean-Louis Pepin
- Laboratoire HP2, INSERM U1042, Université Grenoble Alpes, Faculté de Médecine/Pharmacie, 38700 La Tronche, France Laboratoire HP2, INSERM U1042, Explorations Fonctionnelles Respiratoires, CHU Grenoble, France Service EFCR, Physiologie Sommeil et Exercice, Pole Thorax et Vaisseaux, CHU Grenoble, CS10217, 38043 Grenoble Cedex 9, France
| |
Collapse
|
45
|
Jaffuel D, Philippe C, Rabec C, Mallet JP, Georges M, Redolfi S, Palot A, Suehs CM, Nogue E, Molinari N, Bourdin A. What is the remaining status of adaptive servo-ventilation? The results of a real-life multicenter study (OTRLASV-study) : Adaptive servo-ventilation in real-life conditions. Respir Res 2019; 20:235. [PMID: 31665026 PMCID: PMC6819598 DOI: 10.1186/s12931-019-1221-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Accepted: 10/17/2019] [Indexed: 11/20/2022] Open
Abstract
BACKGROUNDS As a consequence of the increased mortality observed in the SERVE-HF study, many questions concerning the safety and rational use of ASV in other indications emerged. The aim of this study was to describe the clinical characteristics of ASV-treated patients in real-life conditions. METHODS The OTRLASV-study is a prospective, 5-centre study including patients who underwent ASV-treatment for at least 1 year. Patients were consecutively included in the study during the annual visit imposed for ASV-reimbursement renewal. RESULTS 177/214 patients were analysed (87.57% male) with a median (IQ25-75) age of 71 (65-77) years, an ASV-treatment duration of 2.88 (1.76-4.96) years, an ASV-usage of 6.52 (5.13-7.65) hours/day, and 54.8% were previously treated via continuous positive airway pressure (CPAP). The median Epworth Scale Score decreased from 10 (6-13.5) to 6 (3-9) (p < 0.001) with ASV-therapy, the apnea-hypopnea-index decreased from 50 (38-62)/h to a residual device index of 1.9 (0.7-3.8)/h (p < 0.001). The majority of patients were classified in a Central-Sleep-Apnea group (CSA; 59.3%), whereas the remaining are divided into an Obstructive-Sleep-Apnea group (OSA; 20.3%) and a Treatment-Emergent-Central-Sleep-Apnea group (TECSA; 20.3%). The Left Ventricular Ejection Fraction (LVEF) was > 45% in 92.7% of patients. Associated comorbidities/etiologies were cardiac in nature for 75.7% of patients (neurological for 12.4%, renal for 4.5%, opioid-treatment for 3.4%). 9.6% had idiopathic central-sleep-apnea. 6.2% of the patients were hospitalized the year preceding the study for cardiological reasons. In the 6 months preceding inclusion, night monitoring (i.e. polygraphy or oximetry during ASV usage) was performed in 34.4% of patients, 25.9% of whom required a subsequent setting change. According to multivariable, logistic regression, the variables that were independently associated with poor adherence (ASV-usage ≤4 h in duration) were TECSA group versus CSA group (p = 0.010), a higher Epworth score (p = 0.019) and lack of a night monitoring in the last 6 months (p < 0.05). CONCLUSIONS In real-life conditions, ASV-treatment is often associated with high cardiac comorbidities and high compliance. Future research should assess how regular night monitoring may optimize devices settings and patient management. TRIAL REGISTRATION The OTRLASV study is registered on ClinicalTrials.gov (Identifier: NCT02429986 ) on 1 April 2015.
Collapse
Affiliation(s)
- Dany Jaffuel
- Department of Respiratory Diseases, Montpellier University Hospital, Hôpital Arnaud de Villeneuve, 371 avenue du Doyen Gaston Giraud, 34295 Montpellier, Cedex 5 France
- Pulmonary Disorders and Respiratory Sleep Disorders Unit, Polyclinic Saint-Privat, 34760 Boujan sur Libron, France
| | - Carole Philippe
- Centre des pathologies du sommeil, Hôpital Universitaire de la Pitié Salpêtrière, AP-HP, Paris, France
| | - Claudio Rabec
- Pulmonary Department and Respiratory Critical Care Unit, University Hospital Dijon, Dijon, France
| | - Jean-Pierre Mallet
- Department of Respiratory Diseases, Montpellier University Hospital, Hôpital Arnaud de Villeneuve, 371 avenue du Doyen Gaston Giraud, 34295 Montpellier, Cedex 5 France
| | - Marjolaine Georges
- Pulmonary Department and Respiratory Critical Care Unit, University Hospital Dijon, Dijon, France
| | - Stefania Redolfi
- Centre des pathologies du sommeil, Hôpital Universitaire de la Pitié Salpêtrière, AP-HP, Paris, France
| | - Alain Palot
- Clinique des Bronches, Allergies et du Sommeil, Assistance Publique Hôpitaux de Marseille, Marseille, France
- INSERM U1067, CNRS UMR 7333 Aix Marseille Université, 13015 Marseille, France
- Hôpital Saint-Joseph, 26, boulevard de Louvain, 13285 Marseille, France
| | - Carey M. Suehs
- Department of Respiratory Diseases, Montpellier University Hospital, Hôpital Arnaud de Villeneuve, 371 avenue du Doyen Gaston Giraud, 34295 Montpellier, Cedex 5 France
- Department of Medical Information, Montpellier University Hospital, Montpellier, France
| | - Erika Nogue
- Clinical Research and Epidemiology Unit (URCE), Montpellier University Hospital, Montpellier, France
| | - Nicolas Molinari
- Department of Medical Information, Montpellier University Hospital, Montpellier, France
- IMAG, CNRS, Montpellier University, Montpellier University Hospital, Montpellier, France
| | - Arnaud Bourdin
- Department of Respiratory Diseases, Montpellier University Hospital, Hôpital Arnaud de Villeneuve, 371 avenue du Doyen Gaston Giraud, 34295 Montpellier, Cedex 5 France
- PhyMedExp (INSERM U 1046, CNRS UMR9214), Montpellier University, Montpellier, France
| |
Collapse
|
46
|
Donovan LM, Shah A, Chai-Coetzer CL, Barbé F, Ayas NT, Kapur VK. Redesigning Care for OSA. Chest 2019; 157:966-976. [PMID: 31639334 DOI: 10.1016/j.chest.2019.10.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2019] [Revised: 09/09/2019] [Accepted: 10/01/2019] [Indexed: 02/07/2023] Open
Abstract
Constrained by a limited supply of specialized personnel, health systems face a challenge in caring for the large number of patients with OSA. The complexity of this challenge is heightened by the varied clinical presentations of OSA and the diversity of treatment approaches. Innovations such as simplified home-based care models and the incorporation of nonspecialist providers have shown promise in the management of uncomplicated patients, producing comparable outcomes to the resource-intensive traditional approach. However, it is unclear if these innovations can meet the needs of all patients with OSA, including those with mild disease, atypical presentations, and certain comorbid medical and mental health conditions. This review discusses the diversity of needs in OSA care, the evidence base behind recent care innovations, and the potential limitations of each innovation in meeting the diversity of care needs. We propose how these innovations can fit within the stepped care and hub and spoke models in a way that addresses the full spectrum of OSA, and we discuss future research directions to assess the deployment of these innovations.
Collapse
Affiliation(s)
- Lucas M Donovan
- HSR&D Center of Innovation for Veteran-Centered and Value-Driven Care, Veterans Affairs Puget Sound Health Care System, Seattle, WA; University of Washington School of Medicine, Seattle, WA
| | - Aditi Shah
- Leon Judah Blackmore Sleep Disorders Program, University of British Columbia, Vancouver, BC, Canada
| | - Ching Li Chai-Coetzer
- Adelaide Institute for Sleep Health, Flinders University, Adelaide, SA, Australia; Respiratory and Sleep Service, Southern Adelaide Local Health Network, SA Health, Adelaide, SA, Australia
| | - Ferran Barbé
- Institut de Recerca Biomèdica of Lleida and CIBERES, Lleida, Catalonia, Spain
| | - Najib T Ayas
- Leon Judah Blackmore Sleep Disorders Program, University of British Columbia, Vancouver, BC, Canada
| | | |
Collapse
|
47
|
Edwards BA, Redline S, Sands SA, Owens RL. More Than the Sum of the Respiratory Events: Personalized Medicine Approaches for Obstructive Sleep Apnea. Am J Respir Crit Care Med 2019; 200:691-703. [PMID: 31022356 PMCID: PMC6775874 DOI: 10.1164/rccm.201901-0014tr] [Citation(s) in RCA: 95] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Accepted: 04/22/2019] [Indexed: 11/16/2022] Open
Abstract
Traditionally, the presence and severity of obstructive sleep apnea (OSA) have been defined by the apnea-hypopnea index (AHI). Continuous positive airway pressure is generally first-line therapy despite low adherence, because it reliably reduces the AHI when used, and the response to other therapies is variable. However, there is growing appreciation that the underlying etiology (i.e., endotype) and clinical manifestation (i.e., phenotype) of OSA in an individual are not well described by the AHI. We define and review the important progress made in understanding and measuring physiological mechanisms (or endotypes) that help define subtypes of OSA and identify the potential use of genetics to further refine disease classification. This more detailed understanding of OSA pathogenesis should influence clinical treatment decisions as well as help inform research priorities and clinical study design. In short, treatments could be individualized on the basis of the underlying cause of OSA; patients could better understand which symptoms and outcomes will respond to OSA treatment and by how much; and researchers could select populations most likely to benefit from specific treatment approaches for OSA.
Collapse
Affiliation(s)
- Bradley A. Edwards
- Sleep and Circadian Medicine Laboratory, Department of Physiology, and
- School of Psychological Sciences, Turner Institute for Brain and Mental Health, Monash University, Melbourne, Victoria, Australia
- Division of Sleep and Circadian Disorders, Department of Medicine and Department of Neurology, Brigham & Women’s Hospital and Harvard Medical School, Boston, Massachusetts; and
| | - Susan Redline
- Division of Sleep and Circadian Disorders, Department of Medicine and Department of Neurology, Brigham & Women’s Hospital and Harvard Medical School, Boston, Massachusetts; and
| | - Scott A. Sands
- Division of Sleep and Circadian Disorders, Department of Medicine and Department of Neurology, Brigham & Women’s Hospital and Harvard Medical School, Boston, Massachusetts; and
| | - Robert L. Owens
- Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego, La Jolla, California
| |
Collapse
|
48
|
Light M, Owens RL, Schmickl CN, Malhotra A. Precision Medicine for Obstructive Sleep Apnea. Sleep Med Clin 2019; 14:391-398. [DOI: 10.1016/j.jsmc.2019.05.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
49
|
Pépin J, Bailly S, Tamisier R. Big Data in sleep apnoea: Opportunities and challenges. Respirology 2019; 25:486-494. [DOI: 10.1111/resp.13669] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 06/13/2019] [Accepted: 07/23/2019] [Indexed: 12/13/2022]
Affiliation(s)
- Jean‐Louis Pépin
- HP2 Laboratory, INSERM U1042University Grenoble Alpes Grenoble France
- EFCR LaboratoryCHU de Grenoble Alpes Grenoble France
| | - Sébastien Bailly
- HP2 Laboratory, INSERM U1042University Grenoble Alpes Grenoble France
- EFCR LaboratoryCHU de Grenoble Alpes Grenoble France
| | - Renaud Tamisier
- HP2 Laboratory, INSERM U1042University Grenoble Alpes Grenoble France
- EFCR LaboratoryCHU de Grenoble Alpes Grenoble France
| |
Collapse
|
50
|
Krakow B, McIver ND, Ulibarri VA, Krakow J, Schrader RM. Prospective Randomized Controlled Trial on the Efficacy of Continuous Positive Airway Pressure and Adaptive Servo-Ventilation in the Treatment of Chronic Complex Insomnia. EClinicalMedicine 2019; 13:57-73. [PMID: 31517263 PMCID: PMC6734001 DOI: 10.1016/j.eclinm.2019.06.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 05/28/2019] [Accepted: 06/19/2019] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Complex insomnia, the comorbidity of chronic insomnia and obstructive sleep apnea (OSA), is a common sleep disorder, but the OSA component, whether presenting overtly or covertly, often goes unsuspected and undiagnosed due to a low index of suspicion. Among complex insomniacs, preliminary evidence demonstrates standard CPAP decreases insomnia severity. However, CPAP causes expiratory pressure intolerance or iatrogenic central apneas that may diminish its use. An advanced PAP mode-adaptive servo-ventilation (ASV)-may alleviate CPAP side-effects and yield superior outcomes. METHODS In a single-site protocol investigating covert complex insomnia (ClinicalTrials.gov identifier: NCT02365064), a low index of suspicion for this comorbidity was confirmed by exclusion of 455 of 660 eligible patients who presented during the study period with overt OSA signs and symptoms. Ultimately, stringent inclusion/exclusion criteria to test efficacy yielded 40 adult, covert complex insomnia patients [average Insomnia Severity Index (ISI) moderate-severe 19.30 (95% CI 18.42-20.17)] who reported no definitive OSA symptoms or risks and who failed behavioral or drug therapy for an average of one decade. All 40 were diagnosed with OSA and randomized (using block randomization) to a single-blind, prospective protocol, comparing CPAP (n = 21) and ASV (n = 19). Three successive PAP titrations fine-tuned pressure settings, facilitated greater PAP use, and collected objective sleep and breathing data. Patients received 14 weeks of treatment including intensive biweekly coaching and follow-up to foster regular PAP use in order to accurately measure efficaciousness. Primary outcomes measured insomnia severity and sleep quality. Secondary outcomes measured daytime impact: OSA-induced impairment, fatigue severity, insomnia impairment, and quality of life. Performance on these seven variables was assessed using repeated measures ANCOVA to account for the multiple biweekly time points. FINDINGS At intake, OSA diagnosis and OSA as a cause for insomnia were denied by all 40 patients, yet PAP significantly decreased insomnia severity scores (p = 0.021 in the primary ANCOVA analysis). To quantify effect sizes, mean intake vs endpoint analysis was conducted with ASV yielding nearly twice the effects of CPAP [- 13.2 (10.7-15.7), Hedges' g = 2.50 vs - 9.3 (6.3-12.3), g = 1.39], and between mode effect size was in the medium-large range 0.65. Clinically, ASV led to remission (ISI < 8) in 68% of cases compared to 24% on CPAP [Fisher's exact p = 0.010]. Two sleep quality measures in the ANCOVA analysis again demonstrated superior significant effects for ASV compared to CPAP (both p < 0.03), and pre- and post-analysis demonstrated substantial effects for both scales [ASV (g = 1.42; g = 1.81) over CPAP (g = 1.04; g = 0.75)] with medium size effects between modes (0.54, 0.51). Measures of impairment, residual objective sleep breathing events, and normalized breathing periods consistently demonstrated larger beneficial effects for ASV over CPAP. INTERPRETATION PAP therapy was highly efficacious in decreasing insomnia severity in chronic insomnia patients with previously undiagnosed co-morbid OSA. ASV proved superior to CPAP in this first efficacy trial to compare advanced to traditional PAP modes in complex insomnia. Future research must determine the following: pathophysiological mechanisms to explain how OSA causes chronic insomnia; general population prevalence of this comorbidity; and, cost-effectiveness of ASV therapy in complex insomnia. Last, efforts to raise awareness of complex insomnia are urgently needed as patients and providers appear to disregard both overt and covert signs and symptoms of OSA in the assessment of chronic insomnia.
Collapse
Affiliation(s)
- Barry Krakow
- Sleep & Human Health Institute, 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
- Maimonides Sleep Arts & Sciences, Ltd., 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
| | - Natalia D. McIver
- Sleep & Human Health Institute, 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
- Maimonides Sleep Arts & Sciences, Ltd., 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
| | - Victor A. Ulibarri
- Sleep & Human Health Institute, 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
- Maimonides Sleep Arts & Sciences, Ltd., 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
| | - Jessica Krakow
- Sleep & Human Health Institute, 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
- Maimonides Sleep Arts & Sciences, Ltd., 6739 Academy Rd NE, Ste 380, Albuquerque, NM 87109, USA
| | - Ronald M. Schrader
- RMS Biostatistics Services, 13129 Bluemist Ln NE, Albuquerque, NM 87111, USA
| |
Collapse
|