1
|
Cook KE, Baty BJ, Dent KM, Kaphingst KA, Erby LH. Defining orienting language in the genetic counseling process. J Genet Couns 2023. [PMID: 36806333 PMCID: PMC10405641 DOI: 10.1002/jgc4.1675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 12/23/2022] [Accepted: 12/26/2022] [Indexed: 02/22/2023]
Abstract
We defined orienting language in genetic counseling sessions as 'language intended to direct focus to a particular aspect of the counseling process; a physical, emotional, or cognitive space; or an outcome'. This is a concept expanding on the idea of 'orientation' statements in the genetic counseling literature. We propose that orienting language is an important component of effective communication in the genetic counseling process. Our goals were to document the presence of orienting language in genetic counseling sessions with practicing genetic counselors and simulated clients, categorize types of orienting language, and evaluate the purpose of this language. A sample of Genetic Counseling Video Project videotape transcripts was evaluated through consensus coding for orienting language. Orienting language was found to be abundant in the dataset evaluated. Each excerpt was coded for orienting language Strategies and Purpose. The six categories of Strategy codes identified were Logical Consistency, Providing Context, Guidance, Structuring the Session, Anchoring, and Procedural. The six categories of Purpose codes were Counselee Understanding, Guidance, Engagement, Promoting Effective Counselor/Counselee Interactions, Counselee Adaptation, and Relationship Building. Results support our expanded definition of orienting language, which was similar in both cancer and prenatal specialties and across years of counselor experience. Orienting language acts as a series of signposts to help clients navigate the sometimes complex and unfamiliar territory of a genetic counseling session. The introduction of this term into the genetic counseling literature allows its use by genetic counselors to be further evaluated and potentially incorporated into genetic counselor training.
Collapse
Affiliation(s)
- Katherine E Cook
- Graduate Program in Genetic Counseling, University of Utah, Utah, Salt Lake City, USA.,St. Luke's Cancer Institute, Idaho, Boise, USA
| | - Bonnie J Baty
- Graduate Program in Genetic Counseling, University of Utah, Utah, Salt Lake City, USA
| | - Karin M Dent
- Graduate Program in Genetic Counseling, University of Utah, Utah, Salt Lake City, USA
| | - Kimberly A Kaphingst
- Department of Communication, University of Utah, Utah, Salt Lake City, USA.,Huntsman Cancer Institute, Utah, Salt Lake City, USA
| | - Lori H Erby
- Johns Hopkins Bloomberg School of Public Health, Maryland, Baltimore, USA.,Center for Precision Health Research, National Human Genome Research Institute, National Institutes of Health, Maryland, Bethesda, USA
| |
Collapse
|
2
|
Griffith GW, Toomasian JM, Schreiner RJ, Dusset CM, Cook KE, Osterholzer KR, Merz SI, Bartlett RH. Hematological changes during short-term tidal flow extracorporeal life support. Perfusion 2016; 19:359-63. [PMID: 15619969 DOI: 10.1191/0267659104pf766oa] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to achieve both venous drainage and arterialized reinfusion through a series of tubing occluders that are automated by a pump. A single venous occluder tidal flow system with a 15 Fr single-lumen cannula (n- 6) and passive filling M pump was compared to a conventional 14 Fr dual-lumen cannula (n- 7) and roller pump for four hours of VV ECLS. The changes in platelet count and plasma-free hemoglobin (pHgb) were compared. The results showed a decline in platelet counts typical of ECLS in both groups that were not significantly different from each other. A small elevation in pHgb did not rise above normal clinical levels of 15 mg/dL in either group after four hours of ECLS. Some recirculation was observed and needs to be addressed in future studies. Single occluder tidal flow ECLS may be feasible and efficacious for long-term application once recirculation is resolved and the system evaluated for long-term support.
Collapse
Affiliation(s)
- G W Griffith
- Department of General Surgery, University of Michigan Medical Center, Ann Arbor, MI, USA
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Camboni D, Akay B, Schmid C, Sassalos P, Cook KE, Bartlett R. Novel treatment concept for acute severe pulmonary hypertension with right to left atrial shunting and veno-venous extracorporeal membrane oxygenation. Thorac Cardiovasc Surg 2011. [DOI: 10.1055/s-0030-1269298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Ganz JB, Sigafoos J, Simpson RL, Cook KE. Generalization of a Pictorial Alternative Communication System across Instructors and Distance. Augment Altern Commun 2009; 24:89-99. [DOI: 10.1080/07434610802113289] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
5
|
Dodge-Khatami A, Backer CL, Holinger LD, Mavroudis C, Cook KE, Crawford SE. Healing of a free tracheal autograft is enhanced by topical vascular endothelial growth factor in an experimental rabbit model. J Thorac Cardiovasc Surg 2001; 122:554-61. [PMID: 11547309 DOI: 10.1067/mtc.2001.116206] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE In 1996, we introduced the free tracheal autograft technique for repair of congenital tracheal stenosis from complete tracheal rings in infants and children. Sources of possible concern with this procedure include the potential for autograft ischemia, patch dehiscence, and recurrent stenosis. Vascular endothelial growth factor is a potent angiogenic inducer (particularly in the setting of ischemia, hypoxia, or both) and is postulated to promote tissue healing. The purpose of this study was to test the hypothesis that pretreatment of tracheal autografts with topical vascular endothelial growth factor would enhance tracheal healing. METHODS In a rabbit model of tracheal reconstruction (n = 32), an elliptically shaped portion of the anterior tracheal wall was excised. The excised portion of trachea was one third of the tracheal circumference and 2 cm in length (6 tracheal rings). This portion of trachea (the autograft) was soaked in either vascular endothelial growth factor (5 microg/mL, n = 16) or normal saline solution (n = 16) for 15 minutes before being reimplanted in the resultant tracheal opening. Animals were killed and autografts were examined at 2 weeks, 1 month, and 2 months postoperatively for gross and microscopic characteristics. RESULTS By 2 weeks, and progressing through 1 and 2 months, autografts treated with vascular endothelial growth factor, as compared with control autografts, had reduced luminal stenosis, submucosal fibrosis, and inflammatory infiltrate (P <.05). The autografts tended to become malaligned in control animals, whereas the tracheal architecture was preserved in rabbits treated with vascular endothelial growth factor. Microvascular vessel density was significantly greater in all vascular endothelial growth factor groups (P <.05) at all time intervals. CONCLUSIONS Topical treatment of free tracheal autografts with vascular endothelial growth factor in a rabbit tracheal reconstruction model enhanced healing, as evidenced by accelerated autograft revascularization, reduced submucosal fibrosis and inflammation, and preservation of the normal tracheal architecture. Topical vascular endothelial growth factor may improve future results of tracheal reconstruction.
Collapse
Affiliation(s)
- A Dodge-Khatami
- Northwestern University Medical School, Department of Surgery, Division of Cardiovascular-Thoracic Surgery, Children's Memorial Hospital, Chicago, Ill 60614-3394, USA
| | | | | | | | | | | |
Collapse
|
6
|
Abstract
Unlike dialysis, which functions as a bridge to renal transplantation, or a ventricular assist device, which serves as a bridge to cardiac transplantation, no suitable bridge to lung transplantation exists. Our goal is to design and build an ambulatory artificial lung that can be perfused entirely by the right ventricle and completely support the metabolic O2 and CO2 requirements of an adult. Such a device could realize a substantial clinical impact as a bridge to lung transplantation, as a support device immediately post-lung transplant, and as a rescue and/or supplement to mechanical ventilation during the treatment of severe respiratory failure. Research on the artificial lung has focused on the design, mode of attachment to the pulmonary circulation, and intracorporeal versus paracorporeal placement of the device.
Collapse
Affiliation(s)
- J B Zwischenberger
- Division of Cardiothoracic Surgery, The University of Texas Medical Branch, Galveston 77555, USA
| | | | | | | | | | | |
Collapse
|
7
|
Abstract
A thoracic artificial lung (TAL) was designed to treat respiratory insufficiency, acting as a temporary assist device in acute cases or as a bridge to transplant in chronic cases. We developed a computational model of the pulmonary circulatory system with the TAL inserted. The model was employed to investigate the effects of parameter values and flow distributions on power generated by the right ventricle, pulsatility in the pulmonary system, inlet flow to the left atrium, and input impedance. The ratio of right ventricle (RV) power to cardiac output ranges between 0.05 and 0.10 W/(L/min) from implantation configurations of low impedance to those of high impedance, with a control value of 0.04 W/(L/min). Addition of an inlet compliance to the TAL reduces right heart power (RHP) and impedance. A compliant TAL housing reduces flow pulsatility in the fiber bundle, thus affecting oxygen transfer rates. An elevated bundle resistance reduces flow pulsatility in the bundle, but at the expense of increased right heart power. The hybrid implantation mode, with inflow to the TAL from the proximal pulmonary artery (PA), outflow branches to the distal PA and the left atrium (LA), a band around the PA between the two anastomoses, and a band around the outlet graft to the LA, is the best compromise between hemodynamic performance and preservation of some portion of the nonpulmonary functions of the natural lungs.
Collapse
Affiliation(s)
- F Boschetti
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | | | | | | |
Collapse
|
8
|
Cook KE, Makarewicz AJ, Backer CL, Mockros LF, Przybylo HJ, Crawford SE, Hernandez JM, Leonard RJ, Mavroudis C. Testing of an intrathoracic artificial lung in a pig model. ASAIO J 1996; 42:M604-9. [PMID: 8944952 DOI: 10.1097/00002480-199609000-00059] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
A low input impedance, intrathoracic artificial lung is being developed for use in acute respiratory failure or as a bridge to transplantation. The device uses microporous, hollow fibers in a 0.74 void fraction, 1.83 m2 surface area bundle. The bundle is placed within a thermoformed polyethylene terephthalate glucose modified housing with a gross volume of 800 cm3. The blood inlet and outlet are 18 mm inner diameter vascular grafts. Between the inlet graft and the device is a 1 inch inner diameter, thin-walled, latex tubing compliance chamber. These devices were implanted in Yorkshire pigs via median sternotomy with an end to side anastomosis to the pulmonary artery and left atrium. The distal pulmonary artery was occluded to divert the right ventricular output to the device. Pigs 1 and 2 were supported fully for 24 hrs and then killed. Pig 3 was supported partially for 20 hrs and died from bleeding complications. The first implant, in a 55 kg male pig, transferred an average of 176 ml/min +/- 42.4 of O2 and 190 ml/min +/- 39.7 of CO2 with an average blood flow rate of 2.71/min +/- 0.46. The normalized average right ventricular output power, Pn, was 0.062 W/(L/min) +/- 0.0082, and the average device resistance, R, was 3.5 mmHg/(L/min) +/- 0.62. The second implant, in a 60 kg male pig, transferred an average of 204 ml/min +/- 22.5 of O2 and 242 ml/min +/- 17.2 of CO2 with an average blood flow rate of 3.7 L/min +/- 0.45, Pn of 0.064 W/(L/min) +/- 0.0067, and R of 4.3 mmHg/(L/min) +/- 0.89. The third implant, in an 89 kg male pig, transferred an average of 156 ml/min +/- 39.6 of O2 and 187 ml/min +/- 21.4 of CO2 with an average blood flow rate of 2.5 L/min +/- 0.49, Pn of 0.052 W/(l/min) +/- 0.0067, and R of 3.4 mmHg/(L/min) +/- 0.74. These experiments suggest that such an artificial lung can temporarily support the gas transfer requirements of adult humans without over-loading the right ventricle.
Collapse
Affiliation(s)
- K E Cook
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Abstract
A semiempirical mathematical model of convective oxygen transport is used to design a new, low pressure loss, implantable artificial lung that could be used as a bridge to lung transplantation in patients with advanced respiratory failure. The mass transfer and flow friction relations pertinent to the design of a cross-flow hollow fiber membrane lung are described. The artificial lung is designed to transfer over 200 ml/min of oxygen at blood flow rates up to 5 L/min. A compact design and a blood-side pressure loss of < 15 mm Hg allows the device to be implanted in the left chest without the need for a prosthetic blood pump. Surgical implantation of the artificial lung would require the creation of inflow and outflow anastomoses. Oxygen would be supplied via an external source. Blood properties, operating conditions, and empirically determined mass transfer and flow properties are all specified and input into a computer program that numerically solves the design equations. Computer-generated values for the device frontal area, blood path length, and fiber surface area are thereby obtained. The use of this computer-assisted design minimizes the need for extensive trial-and-error testing of prototype devices. Results from in vitro tests of a prototype implantable lung indicate that the mathematical model we describe is an accurate and useful tool in the design of hollow fiber artificial lungs.
Collapse
Affiliation(s)
- S N Vaslef
- Department of Surgery, Evanston Hospital, IL 60201
| | | | | | | | | | | |
Collapse
|
10
|
Abstract
The authors designed and tested an artificial lung intended for intrathoracic implantation as a bridge to lung transplantation in chronic pulmonary insufficiency or as an alternative in the treatment of advanced acute respiratory failure. The prototype devices are comprised of 380 microns outer diameter polypropylene matted fibers with a blood path length of 3.5 cm, frontal area of 128 cm2, void fraction (porosity) of 0.53, and surface area of approximately 2.2 m2. Blood flow is external and approximately perpendicular to the fiber bundle, which fits in an extruded, flexible polyethylene terephthalate housing. Inflow and outflow anastomoses are made to the pulmonary artery and the left atrium, respectively, thereby avoiding a prosthetic blood pump. Inlet and outlet gas lines exit through the chest wall. Nine in vitro experiments of oxygen (O2) transfer performance by the device, with water, initially were done. Our previously described semiempirical mathematical model of convective O2 transfer in cross-flow, hollow fiber membrane lungs was applied to the results from the water tests to predict the transfer rates at any set of blood conditions. Five in vitro blood tests were conducted using a single-pass technique to evaluate O2 and carbon dioxide (CO2) transfer rates, measure pressure losses, and compare predicted and measured O2 transfer rates. O2 transfer rates of 150-200 ml/min, and CO2 transfer rates exceeding 200 ml/min, could be achieved at blood flow rates as great as 4 l/min. Pressure drops of approximately 10-20 mmHg were observed at blood flow rates of 2-4 l/min. Preliminary results of device implantation in two pigs indicate the feasibility of achieving clinically significant O2 and CO2 transfer rates with a low blood-side pressure loss.
Collapse
Affiliation(s)
- S N Vaslef
- Department of Surgery, Evanston Hospital, IL 60201, USA
| | | | | | | | | |
Collapse
|
11
|
Abstract
Levels of vitellogenin (Vg) mRNA in Locusta migratoria fat body were determined as indicators of gene expression induced by the juvenile hormone analog methoprene. After injection of methoprene into juvenile hormone-deprived locusts, excised fat bodies were cultured with [3H]leucine for immunochemical assay of Vg synthesis, and RNA was assayed for Vg mRNA content by hybridization with probes from the previously cloned locust Vg genes A and B. In general, the rise in Vg mRNA paralleled the rise in Vg synthesis. During the primary response to methoprene (in female locusts in which the corpora allata had been destroyed immediately after emergence), Vg mRNA was first detected after 18-24 hr and accumulated rapidly between 36 and 48 hr. The secondary response (in locusts allatectomized during vitellogenesis and kept until Vg disappeared) was accelerated, as Vg mRNA was detectable at 12 hr and titers rose steeply after 18 hr. When Vg synthesis was prematurely induced by injection of methoprene into fifth-stage female larvae, the kinetics of mRNA accumulation were similar to those of primary stimulation in the adult. After allatectomy of vitellogenic females, fat body Vg mRNA decayed with a half-life of about 24 hr, roughly paralleling the decline in Vg synthesis. Assays with the two Vg probes showed coordinate accumulation of gene A and gene B messages under all conditions tested: during primary and secondary stimulation in adult females and in the low-level response obtained by treating male larvae with methoprene.
Collapse
|
12
|
Abstract
The Tennessee Self-concept Scale was administered to 125 college freshmen. Both scale- and item-level correlation matrices were generated and factored to examine further the construct validity of the test. The scale-level factor analysis resulted in two essentially independent dimensions identified as self-esteem and integration-conflict. While supporting the results of Rentz and White (1967), the dimensions reflected substantially the item-scale overlap which resulted in clusters of spuriously high correlations. An item-level principal component analysis indicated that 23 factors could adequately describe the item interrelationship for the small sample of college students. Under the limitation of the sample size the analysis generated dimensions defined mainly by the column designated external frame of reference classifications; the row designated internal classifications tended not to group together consistently. Summing item responses across rows to generate the three internal frame of reference scores was thus questioned. Correlations between the factors provided no consistent evidence for arbitrarily collapsing factors to generate the test column designated external classifications. Thus, when using the test with similar samples of college freshmen, caution is in order. Further item-level factor analytic studies with larger, more heterogeneous samples are needed.
Collapse
|