1
|
Al Baalharith MM, Alsary SA, Bin Mosa MA, Almarzouq YF, Basudan SK. Understanding the safe application of electrosurgery: A cross sectional study of surgeons in KSA. J Taibah Univ Med Sci 2023; 18:595-9. [PMID: 36818175 DOI: 10.1016/j.jtumed.2022.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/29/2022] [Accepted: 11/29/2022] [Indexed: 12/23/2022] Open
Abstract
Objectives To determine whether surgeons at different levels and in different specialties are aware of the safe and acceptable use of electrosurgery. In addition, we aimed to provide a fundamental understanding of electrosurgery and surgical diathermy. Materials and Methods A total of 83 doctors from different specialties were randomly selected from several hospitals across KSA. The participants answered a questionnaire featuring 16 questions that addressed 10 domain questions regarding the safe use of electrosurgery. Results Analysis revealed that the respondents either lacked knowledge or were unfamiliar with the use and safety of monopolar and bipolar electrosurgery in terms of application. Some respondents were unable to distinguish between the two protocols; this may have resulted in injuries being incurred by patients under their supervision. Conclusions Electrosurgery should be formally included in specialty surgical Saudi hospital training programs to increase electrosurgery expertise and surgeons should be re-tested periodically. Our findings may be used to drive future learning. Surgeons may improve their electrosurgery skills by progressing along their learning curve to reach their peak. In addition, surgeons can use virtual reality surgical simulators to practice fundamental and sophisticated electrosurgery skills.
Collapse
|
2
|
Hoogstrate Y, Jenster GW, Werken HJGVD. FASTAFS: file system virtualisation of random access compressed FASTA files. BMC Bioinformatics 2021; 22:535. [PMID: 34724897 PMCID: PMC8558547 DOI: 10.1186/s12859-021-04455-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 10/20/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The FASTA file format, used to store polymeric sequence data, has become a bioinformatics file standard used for decades. The relatively large files require additional files, beyond the scope of the original format, to identify sequences and to provide random access. Multiple compressors have been developed to archive FASTA files back and forth, but these lack direct access to targeted content or metadata of the archive. Moreover, these solutions are not directly backwards compatible to FASTA files, resulting in limited software integration. RESULTS We designed a linux based toolkit that virtualises the content of DNA, RNA and protein FASTA archives into the filesystem by using filesystem in userspace. This guarantees in-sync virtualised metadata files and offers fast random-access decompression using bit encodings plus Zstandard (zstd). The toolkit, FASTAFS, can track all its system-wide running instances, allows file integrity verification and can provide, instantly, scriptable access to sequence files and is easy to use and deploy. The file compression ratios were comparable but not superior to other state of the art archival tools, despite the innovative random access feature implemented in FASTAFS. CONCLUSIONS FASTAFS is a user-friendly and easy to deploy backwards compatible generic purpose solution to store and access compressed FASTA files, since it offers file system access to FASTA files as well as in-sync metadata files through file virtualisation. Using virtual filesystems as in-between layer offers format conversion without the need to rewrite code into different programming languages while preserving compatibility.
Collapse
Affiliation(s)
- Youri Hoogstrate
- Department of Neurology, Erasmus University Medical Center, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
- Department of Urology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
- Cancer Computational Biology Center, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Guido W. Jenster
- Department of Urology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Harmen J. G. van de Werken
- Department of Urology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
- Cancer Computational Biology Center, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
- Department of Immunology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
3
|
Bogacki P, Gach T, Krzak J, Szura M. Panoramic colonoscopy in colorectal cancer screening - a randomized controlled trial. Wideochir Inne Tech Maloinwazyjne 2021; 16:289-96. [PMID: 34136023 DOI: 10.5114/wiitm.2021.103922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 10/24/2020] [Indexed: 11/17/2022] Open
Abstract
Introduction Colonoscopy is considered the gold standard for colorectal cancer screening. Panoramic colonoscopy offers better visualization to decrease the adenoma miss rate. Aim To assess the influence of 330° panoramic view colonoscopy on adenoma and polyp detection rate, cecal intubation time, and examiner’s comfort. Material and methods The study enrolled 421 patients aged 18–80 years who were eligible for colonoscopy screening. Patients with prior abdominal surgery, inflammatory bowel disease or after colorectal resections were excluded from the study. Patients were randomized to either standard frontal view (SFV) (Olympus Evis Exera III 190 CF-HQ190L) or the panoramic view colonoscopy (PVC) (FUSE CDVL slim c38). The study was approved by the local bioethics committee and registered at ClinicalTrial.gov (NCT02929381). Results There were 214 patients examined with SFV and 207 with PVC. The mean age of patients was 64 ±12.26 years. The two groups were comparable. The median cecal intubation time was 234 s with SFV vs. 311 s with PVC (p < 0.001). There were no significant differences in CIR or withdrawal time. PVC made it possible to discover more diverticula in the ascending colon (p = 0.009). PDR with SFV was 34.6% and 40.1% with PVC (p = 0.242). A higher number of polyps was found in the transverse colon in the PVC group (p = 0.006). ADR and advanced ADR (aADR) in both groups were similar (26.4% vs. 27.1% and 14, 2% vs. 13.9%). Conclusions Colonoscopy with wide-angle endoscopes lasts longer and allows for the detection of more polyps and diverticula without affecting ADR and aADR. Our study did not reveal the superiority of wide-angle colonoscopy in colorectal cancer screening
Collapse
|
4
|
Pasternak A, Szura M, Solecki R, Bogacki P, Bachul PJ, Walocha JA. The impact of full-spectrum endoscopy on pathological lesion detection in different regions of the colon: a randomised, controlled trial. Arch Med Sci 2021; 17:1636-1642. [PMID: 34900043 PMCID: PMC8641496 DOI: 10.5114/aoms.2019.87714] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Accepted: 11/08/2018] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Colonoscopy is crucial for detecting and localising pathological lesions within the colon. Colonoscopy quality is defined by the caecal intubation rate, withdrawal time, adenoma detection rate, and polyp detection rate. The newly introduced full-spectrum endoscope (FUSE®) provides a 330° field of view, allowing endoscopists to observe more colonic anatomy. It is intended to increase detection of pathological lesions, especially those situated behind the haustral folds of the bowel. This diagnostic modality should increase the adenoma detection rate (ADR), especially in the right hemicolon. The aim of this study was to explore the efficacy of FUSE for detecting pathologic lesions in different colonic regions. MATERIAL AND METHODS The study enrolled 408 patients who were randomised to either a standard frontal view (SFV) or the novel full-spectrum colonoscopy. Analysis was performed among three broad regions of the colon: right, transverse, and left colon, according to the Boston Bowel Preparation Scale. RESULTS FUSE yielded a higher diverticula detection rate (DDR) in the right and middle colon (DDR-R (p < 0.05), DDR-T (p < 0.05), DDR-L (p = 0.862)). ADR (p = 0.761), advanced ADR (aADR) (p = 0.950), and DDR (p = 0.967) in respective regions of the colon were similar between the groups; however, the total number of adenomas detected with FUSE was higher in the right and middle regions of the colon compared with those detected by SFV (p < 0.05). CONCLUSIONS Full-spectrum colonoscopy allows for effective recognition of pathological lesions in the right and middle regions of the colon. Although full-spectrum colonoscopy did not statistically affect ADR, the absolute number of adenomas detected was higher compared with classical endoscopy.
Collapse
Affiliation(s)
- Artur Pasternak
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland
- MEDICINA – Specialist Diagnostic and Therapeutic Centre, Krakow, Poland
| | - Miroslaw Szura
- MEDICINA – Specialist Diagnostic and Therapeutic Centre, Krakow, Poland
- Department of Experimental and Clinical Surgery, Faculty of Health Sciences – Jagiellonian University Medical College, Krakow, Poland
| | - Rafal Solecki
- MEDICINA – Specialist Diagnostic and Therapeutic Centre, Krakow, Poland
- Department of Experimental and Clinical Surgery, Faculty of Health Sciences – Jagiellonian University Medical College, Krakow, Poland
| | - Pawel Bogacki
- MEDICINA – Specialist Diagnostic and Therapeutic Centre, Krakow, Poland
| | - Piotr J. Bachul
- Department of Surgery, University of Chicago, Chicago, IL, USA
| | - Jerzy A. Walocha
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland
| |
Collapse
|
5
|
Malik AA, Khan RS, Khan RN, Shakeel O, Ahmed HH, Rahid U, Fatima A, Afzal MF, Khattak S, Syed AA. Lack of awareness among surgeons regarding safe use of electrosurgery. A cross sectional survey of surgeons in Pakistan. Ann Med Surg (Lond) 2020; 50:24-27. [PMID: 31938542 PMCID: PMC6953526 DOI: 10.1016/j.amsu.2019.11.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/20/2019] [Accepted: 11/25/2019] [Indexed: 11/16/2022] Open
Abstract
Objective To assess our surgeons perceptive regarding the safe usage of electrosurgical devices. Method ology: This cross sectional survey was carried out at two hospitals, A cancer hospital and a public sector general hospital. Consultants, fellows and senior residents (Resident year 3rd and year 4th) on the surgical floor were requested to fill up the questionnaire. Calculations were performed with Statistical Package for the Social Sciences (SPSS 20) for Windows version 20 statistical software. Data was described using median with minimum and maximum value for quantitative variables. For categorical variables, number of observations and percentages were reported. The study is complied with hospital guidelines on research involving human subjects. Results Out of 80 questionnaires 52 were filled and returned. 12 consultants, 16 fellows/Senior registrars and 24 senior residents filled their questionnaires. For the sake of anonymity no information was obtained regarding the level of training and experience. Total 12 questions were asked. An expert level was set for a score above 10/12. A moderate level was set at 8/12. A score of less than 8 was considered unsafe for using electrosurgical devices. Only 6 (11.5%) participants had an expert level of understanding. 16 (30.7%) had moderate understanding. 30 (57.7%) were considered unsafe regarding use of electrosurgical devices. 85% participants were not aware of the correct mode of current to use for coagulating vessels. 69% of surgeons would use electrocautery to control staple line bleeds. 67% participants weren't aware of the correct placement of dispersive electrode. 60% couldn't identify a safe device for use in patients with a pacemaker. 46% of surgeons would cut a dispersive electrode to fit it on a child. 69% believed that harmonic scalpel was a bipolar cautery. 61% couldn't differentiate between RFA and Microwave Ablation. 63% didn't know how to handle an operating room fire. Conclusion In these two hospitals, high level of ignorance noticed regarding the procedure and indications of basic electrosurgical equipment which needs raising awareness and further training. The first study to show the lack of understanding of electrosurgical devices among surgeons in Pakistan. Study was performed in 2 hospitals and included consultants, fellows and residents A survey was distributed and questions pertinent to the use of electrosurgical devices were asked. Surgical residents, fellows and consultants were equally unaware of how these devices work. Study highlights the need to start training courses for these devices.
Collapse
|
6
|
Gugenheim J, Debs T, Gravié JF, Deleuze A, Millat B, Borie F, Mathonnet M. Results of the FUSE Evaluation Project in France. Surg Endosc 2019; 34:1819-1822. [PMID: 31218424 DOI: 10.1007/s00464-019-06938-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 06/13/2019] [Indexed: 01/02/2023]
Abstract
BACKGROUND The Federation of Visceral and Digestive Surgery (FCVD) is in charge in France of the continuing medical education of digestive surgeons. Since 2016 and in collaboration with SAGES, it has offered the Fundamental Use of Surgical Energy (FUSE) program as part of the continuing education for surgeons including eLearning and hands-on workshops. METHODS The aim of this study was to evaluate the impact of the FUSE program on the participants by participating in a knowledge test and completing a survey. RESULTS 485 participants fully completed the knowledge test of 18 questions. Post-test assessment showed an increase in the mean score with respect to pre-test assessment, and the surgeons who have participated to the hands-on workshops had a better score. 304 participants filled the survey of 6 questions. The majority were satisfied by the FUSE program and felt that the objectives were achieved. CONCLUSIONS The FUSE program developed by SAGES and adopted by the FCVD in France was very much appreciated by the participants and achieved its educational objectives. Our goal is to spread it as widely as possible to all members of the operating room team.
Collapse
Affiliation(s)
- Jean Gugenheim
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France. .,Department of Digestive Surgery, Archet Hospital, University of Nice-Sophia Antipolis, 151 Route St Antoine de Ginestière, 06200, Nice, France.
| | - Tarek Debs
- Department of Digestive Surgery, Archet Hospital, University of Nice-Sophia Antipolis, 151 Route St Antoine de Ginestière, 06200, Nice, France
| | - Jean-François Gravié
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France.,Department of General and Visceral Surgery, Clinique St Jean Languedoc, 20 Route de Revel, 31400, Toulouse, France
| | - Alain Deleuze
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France
| | - Bertrand Millat
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France
| | - Frédéric Borie
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France.,Department of Digestive Surgery, Carémeau Hospital, University of Montpellier, Place du Professeur Debré, 30900, Nîmes, France
| | - Muriel Mathonnet
- Federation of Visceral and Digestive Surgery, 15 Rue Bayard, 31000, Toulouse, France.,Department of Digestive and Endocrine Surgery, University Hospital of Limoges, 2 Avenue Martin Luther King, 87042, Limoges, France
| |
Collapse
|
7
|
Ha A, Richards C, Criman E, Piaggione J, Yheulon C, Lim R. The safe use of surgical energy devices by surgeons may be overestimated. Surg Endosc 2018; 32:3861-7. [PMID: 29497829 DOI: 10.1007/s00464-018-6116-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 02/07/2018] [Indexed: 10/17/2022]
Abstract
BACKGROUND Surgical energy injuries are an underappreciated phenomenon. Improper use of surgical energy or poor attention to patient safety can result in operating room fires, tissue injuries, and interferences with other electronic devices, while rare complications can be devastatingly severe. Despite this, there is no current standard requirement for educating surgeons on the safe use of energy-based devices or evaluation of electrosurgery (ES) education in residency training, credentialing, or practice. The study aimed to assess the current baseline knowledge of surgeons and surgical trainees with regards to ES across varying experiences at a tertiary level care center. METHODS Surgeons and surgical trainees from seven surgical specialties (General Surgery, Cardiothoracic Surgery, Vascular Surgery, Obstetrics/Gynecology, Orthopedic Surgery, Urology, and Otorhinolaryngology) at a tertiary level care hospital were tested. Testing included an evaluation regarding their background training and experiences with ES-related adverse events and a 15 multiple-choice-question exam testing critical knowledge of ES. RESULTS A total of 134 surveys were sent out with 72 responses (53.7%). The mean quiz score was 51.5 ± 15.5% (passing score was 80%). Of staff surgeons, 33/65 (50.8%) completed the survey with mean and median scores of 54.9 and 53.3%, respectively (range 33.3-86.7%). Of surgical trainees, 39/69 (56.5%) completed the survey with mean and median scores of 48.6 and 46.7%, respectively (range 13.3-80.0%). There were no statistically significant differences based on training status (p = 0.08), previous training (p = 0.24), number of cases (p = 0.06), or specialty (p = 0.689). CONCLUSION Surgeons and surgical trainees both have a significant knowledge gap in the safe and effective use of surgical energy devices, regardless of surgical specialty and despite what they feel was adequate training. The knowledge gap is not improved with experience. A formal surgical energy education program should be a requirement for residency training or credentialing.
Collapse
|
8
|
Abstract
OBJECTIVES To investigate the diagnostic performance of Full Spectrum Endoscopy (FUSE) compared to a conventional standard forward-viewing endoscope (SFV). The primary outcome was adenoma detection rate (ADR) and mean adenoma detection. Secondary outcome was feasibility of FUSE opposed to SFV. MATERIALS AND METHODS Consecutive patients participating in the Danish colorectal cancer (CRC) screening programme were prospectively included in the study (n = 205). Demographic and health-related characteristics were obtained. Following procedural parameters were recorded: completion rate, caecal intubation time, fentanyl and midazolam sedation, CRC detection, ADR, diverticulosis, bowel preparation, patient discomfort and endoscopist difficulty rating. Participants underwent FUSE colonoscopy on days when the FUSE system was available, while the remaining participants had SFV. All colonoscopies were performed by two trained endoscopists. RESULTS A total of 109 patients were included in the FUSE group and 106 in the SFV group. Groups were comparable in baseline characteristics. Completion rate was 83.5% and 93.4% in the FUSE and SFV groups (p = .040). Caecal intubation time was 11.4 ± 6.7 min versus 9.1 ± 6.2 min in the FUSE and SFV groups (p = .040). ADR was 67.0% and 59.6% (p = .097), while the mean adenoma detection was 1.79 and 1.38 (p = .022) in the FUSE and SFV groups. Endoscopists reported increased difficulty rating with FUSE compared to SFV (p > .001). CONCLUSION FUSE colonoscopy provides a higher mean adenoma detection and there is tendency toward higher ADR compared to SFV in a high-risk population. Nonetheless, FUSE colonoscopy has a lower completion rate, longer caecal intubation time and a higher difficulty rating from an endoscopist point of view.
Collapse
Affiliation(s)
- Søren Roepstorff
- a Digestive Disease Center , Bispebjerg Hospital, University of Copenhagen , Copenhagen , Denmark
| | - Sabah Anwar Hadi
- a Digestive Disease Center , Bispebjerg Hospital, University of Copenhagen , Copenhagen , Denmark
| | - Morten Rasmussen
- a Digestive Disease Center , Bispebjerg Hospital, University of Copenhagen , Copenhagen , Denmark
| |
Collapse
|
9
|
Dorozhkin D, Olasky J, Jones DB, Schwaitzberg SD, Jones SB, Cao CGL, Molina M, Henriques S, Wang J, Flinn J, De S. OR fire virtual training simulator: design and face validity. Surg Endosc 2017; 31:3527-3533. [PMID: 28039649 PMCID: PMC6232853 DOI: 10.1007/s00464-016-5379-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 11/27/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND The Virtual Electrosurgical Skill Trainer is a tool for training surgeons the safe operation of electrosurgery tools in both open and minimally invasive surgery. This training includes a dedicated team-training module that focuses on operating room (OR) fire prevention and response. The module was developed to allow trainees, practicing surgeons, anesthesiologist, and nurses to interact with a virtual OR environment, which includes anesthesia apparatus, electrosurgical equipment, a virtual patient, and a fire extinguisher. Wearing a head-mounted display, participants must correctly identify the "fire triangle" elements and then successfully contain an OR fire. Within these virtual reality scenarios, trainees learn to react appropriately to the simulated emergency. A study targeted at establishing the face validity of the virtual OR fire simulator was undertaken at the 2015 Society of American Gastrointestinal and Endoscopic Surgeons conference. METHODS Forty-nine subjects with varying experience participated in this Institutional Review Board-approved study. The subjects were asked to complete the OR fire training/prevention sequence in the VEST simulator. Subjects were then asked to answer a subjective preference questionnaire consisting of sixteen questions, focused on the usefulness and fidelity of the simulator. RESULTS On a 5-point scale, 12 of 13 questions were rated at a mean of 3 or greater (92%). Five questions were rated above 4 (38%), particularly those focusing on the simulator effectiveness and its usefulness in OR fire safety training. A total of 33 of the 49 participants (67%) chose the virtual OR fire trainer over the traditional training methods such as a textbook or an animal model. CONCLUSIONS Training for OR fire emergencies in fully immersive VR environments, such as the VEST trainer, may be the ideal training modality. The face validity of the OR fire training module of the VEST simulator was successfully established on many aspects of the simulation.
Collapse
Affiliation(s)
- Denis Dorozhkin
- Center for Modeling, Simulation and Imaging in Medicine (CeMSIM), Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Jaisa Olasky
- Department of Surgery, Mount Auburn Hospital, Harvard Medical School, Cambridge, MA, USA.
| | - Daniel B Jones
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Steven D Schwaitzberg
- Department of Surgery, University at Buffalo, The State University of New York, Buffalo, NY, USA
| | - Stephanie B Jones
- Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Caroline G L Cao
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH, USA
| | - Marcos Molina
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Steven Henriques
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Jinling Wang
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH, USA
| | - Jeff Flinn
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH, USA
| | - Suvranu De
- Center for Modeling, Simulation and Imaging in Medicine (CeMSIM), Rensselaer Polytechnic Institute, Troy, NY, USA
| |
Collapse
|
10
|
Abstract
INTRODUCTION The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) developed The Fundamental Use of Surgical Energy (FUSE) Program to promote safe use of energy devices in the operating room and endoscopy suite. Utilization of the program has been slower than anticipated. This study aims to determine the barriers to implementing FUSE. METHODS An anonymous survey was distributed to a surgery department at an academic teaching hospital (n = 256). Participants indicated their level of training. Answers were measured using a 5-point Likert scale. RESULTS There were 94 (36.7%) respondents to the survey from September 7 to 20, 2016. Fifteen surveys were incomplete, leaving 79 responses for analysis. Most respondents were at the faculty level (45/79, 57.0%). The majority had heard of FUSE (62/79, 78.5%), but only 19 had completed the certification (19/62, 32.3%). There was no difference in the completion rate between faculty and trainees (26.7 vs. 20.6%, OR 1.4, 95% CI 0.49-4.06, p = 0.53). The most common reasons for not taking the exam were lack of time to study (26/43, 60.5%) and lack of time to take the exam (28/43, 62.1%); however, cost was not a barrier (12/43, 27.9%). The majority identified a personal learning gap regarding the safe use of surgical energy (30/43, 69.7%). Of the 19 FUSE-certified respondents, reasons cited for completing the exam included wanting to prevent adverse events to patients and in the operating room (17/19, 89.5% and 17/19, 89.5%), and the belief that the course would make them a safer surgeon (16/19, 84.2%). CONCLUSIONS FUSE teaches the proper use of radiofrequency energy, how to prevent unnecessary injury, and promotes safe practice. Close to three out of every four surgeons self-identified a personal knowledge gap regarding the safe use of surgical energy. Time restraints were cited most commonly as the barrier to starting and completing FUSE. Integrating the FUSE program into resident educational conferences, faculty grand rounds, or national conferences may help improve participation and drive adoption of FUSE certification.
Collapse
Affiliation(s)
- Brian M Nguyen
- Department of General Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA.
| | - Emilie Fitzpatrick
- Department of General Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA
| | - Daniel B Jones
- Department of General Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA
| |
Collapse
|
11
|
Sankaranarayanan G, Li B, Miller A, Wakily H, Jones SB, Schwaitzberg S, Jones DB, De S, Olasky J. Face validation of the Virtual Electrosurgery Skill Trainer (VEST©). Surg Endosc 2016; 30:730-738. [PMID: 26092003 PMCID: PMC4685014 DOI: 10.1007/s00464-015-4267-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Accepted: 05/19/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND Electrosurgery is a modality that is widely used in surgery, whose use has resulted in injuries, OR fires and even death. The SAGES has established the FUSE program to address the knowledge gap in the proper and safe usage of electrosurgical devices. Complementing it, we have developed the Virtual Electrosurgery Skill Trainer (VEST(©)), which is designed to train subjects in both cognitive and motor skills necessary to safely operate electrosurgical devices. The objective of this study is to asses the face validity of the VEST(©) simulator. METHODS Sixty-three subjects were recruited at the 2014 SAGES Learning Center. They all completed the monopolar electrosurgery module on the VEST(©) simulator. At the end of the study, subjects assessed the face validity with questions that were scored on a 5-point Likert scale. RESULTS The subjects were divided into two groups; FUSE experience (n = 15) and no FUSE experience (n = 48). The median score for both the groups was 4 or higher on all questions and 5 on questions on effectiveness of VEST(©) in aiding learning electrosurgery fundamentals. Questions on using the simulator in their own skills lab and recommending it to their peers also scored at 5. Mann-Whitney U test showed no significant difference (p > 0.05) indicating a general agreement. 46% of the respondents preferred VEST compared with 52% who preferred animal model and 2% preferred both for training in electrosurgery. CONCLUSION This study demonstrated the face validity of the VEST(©) simulator. High scores showed that the simulator was visually realistic and reproduced lifelike tissue effects and the features were adequate enough to provide high realism. The self-learning instructional material was also found to be very useful in learning the fundamentals of electrosurgery. Adding more modules would increase the applicability of the VEST(©) simulator.
Collapse
Affiliation(s)
- Ganesh Sankaranarayanan
- Center for Modeling, Simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Baichun Li
- Center for Modeling, Simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
- School of Mechanical Engineering and Automation, Northeastern University, Sheyang, China
| | - Amie Miller
- Boon Shaft School of Medicine, Wright State University, Dayton, OH, USA
| | - Hussna Wakily
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Stephanie B Jones
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | - Daniel B Jones
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Suvranu De
- Center for Modeling, Simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Jaisa Olasky
- Department of Surgery, Mount Auburn Hospital, 300 Mount Auburn Street Suite 407, Cambridge, MA, 02138, USA.
| |
Collapse
|
12
|
Watanabe Y, Kurashima Y, Madani A, Feldman LS, Ishida M, Oshita A, Naitoh T, Noma K, Yasumasa K, Nagata H, Nakamura F, Ono K, Suzuki Y, Matsuhashi N, Shichinohe T, Hirano S. Surgeons have knowledge gaps in the safe use of energy devices: a multicenter cross-sectional study. Surg Endosc 2015; 30:588-592. [PMID: 26017912 DOI: 10.1007/s00464-015-4243-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Accepted: 05/10/2015] [Indexed: 11/29/2022]
Abstract
BACKGROUND Despite the widespread use of surgical energy devices and the potential for rare but serious complications, pilot data from North America suggest that surgeons and surgical trainees have knowledge gaps in their safe use. The purpose of this study was to determine baseline knowledge of general surgeons and surgical trainees regarding the safe use of electrosurgery (ES) across varying levels of experience in Japan. METHODS Participants completed a 35-item multiple-choice question examination, testing critical knowledge of ES. The examination was developed according to the objectives and blueprints of SAGES' Fundamental Use of Surgical Energy™ curriculum. Sections of the examination included: "principles of ES," "ES-related adverse events," "monopolar and bipolar devices," and "pediatric considerations and interference with implantable devices." Scores were compared between PGY > 5 and PGY 1-5 participants. RESULTS A total of 145 general surgeons and surgical trainees of all years after medical school (PGY 1-5: 57, PGY > 5: 88) from ten academic and five community hospitals completed the assessment (mean age 35; 91% male). The mean score in the entire cohort was 58 ± 12% (range 23-83%), with significantly higher scores in the PGY > 5 group compared to the PGY 1-5 group (60 ± 11 vs. 53 ± 12%, p < 0.01). Among all participants, 92% were not familiar with best practices when using ES on patients with a pacemaker; 44% believe that ES uses thermal energy from cautery; 19% did not know how to manage an operating room fire; 16% thought that a dispersive electrode should be cut to fit a child; and 27% believe that insulation failure in minimally invasive surgical instruments is mostly visible under careful inspection. CONCLUSIONS General surgeons and trainees at all levels have knowledge gaps in the safe and effective use of energy devices, regardless of years of experience. There is a need for educational curricula to help address these gaps and contribute to safer surgery.
Collapse
Affiliation(s)
- Yusuke Watanabe
- Department of Gastroenterological Surgery II, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Sapporo, Japan. .,Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, McGill University Health Centre, Montreal, Canada.
| | - Yo Kurashima
- Department of Gastroenterological Surgery II, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Sapporo, Japan
| | - Amin Madani
- Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, McGill University Health Centre, Montreal, Canada
| | - Liane S Feldman
- Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, McGill University Health Centre, Montreal, Canada
| | - Minoru Ishida
- Department of Clinical Engineering, KKR Tonan Hospital, Sapporo, Japan
| | - Akihiko Oshita
- Department of Surgery, JA Hiroshima General Hospital, Hatsukaichi, Japan.,Department of Gastroenterological and Transplant Surgery, Hiroshima University, Hiroshima, Japan
| | - Takeshi Naitoh
- Department of Surgery, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Kazuhiro Noma
- Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Keigo Yasumasa
- Department of Surgery, JCHO Osaka Hospital, Osaka, Japan
| | - Hiroshi Nagata
- Department of General Surgery, Kameta Memorial Center, Kamogawa, Japan
| | | | - Koichi Ono
- Department of Surgery, Obihiro Kosei General Hospital, Obihiro, Japan
| | | | | | - Toshiaki Shichinohe
- Department of Gastroenterological Surgery II, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Sapporo, Japan
| | - Satoshi Hirano
- Department of Gastroenterological Surgery II, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Sapporo, Japan
| |
Collapse
|