1
|
The need for systems thinking to advance Alzheimer's disease research. Psychiatry Res 2024; 333:115741. [PMID: 38277813 DOI: 10.1016/j.psychres.2024.115741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 12/08/2023] [Accepted: 01/12/2024] [Indexed: 01/28/2024]
Abstract
Despite extensive research efforts to mechanistically understand late-onset Alzheimer's disease (LOAD) and other complex mental health disorders, curative treatments remain elusive. We emphasize the multiscale multicausality inherent to LOAD, highlighting the interplay between interconnected pathophysiological processes and risk factors. Systems thinking methods, such as causal loop diagrams and systems dynamic models, offer powerful means to capture and study this complexity. Recent studies developed and validated a causal loop diagram and system dynamics model using multiple longitudinal data sets, enabling the simulation of personalized interventions on various modifiable risk factors in LOAD. The results indicate that targeting factors like sleep disturbance and depressive symptoms could be promising and yield synergistic benefits. Furthermore, personalized interventions showed significant potential, with top-ranked intervention strategies differing significantly across individuals. We argue that systems thinking approaches can open new prospects for multifactorial precision medicine. In future research, systems thinking may also guide structured, model-driven data collection on the multiple interactions in LOAD's complex multicausality, facilitating theory development and possibly resulting in effective prevention and treatment options.
Collapse
|
2
|
The impact of cardiovascular diagnostics and treatments on fall risk in older adults: a scoping review and evidence map. GeroScience 2024; 46:153-169. [PMID: 37864713 PMCID: PMC10828261 DOI: 10.1007/s11357-023-00974-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 10/07/2023] [Indexed: 10/23/2023] Open
Abstract
BACKGROUND We aimed to summarize the published evidence on the fall risk reducing potential of cardiovascular diagnostics and treatments in older adults. METHODS Design: scoping review and evidence map. DATA SOURCES Medline and Embase. ELIGIBILITY CRITERIA all available published evidence; Key search concepts: "older adults," "cardiovascular evaluation," "cardiovascular intervention," and "falls." Studies reporting on fall risk reducing effect of the diagnostic/treatment were included in the evidence map. Studies that investigated cardiovascular diagnostics or treatments within the context of falls, but without reporting a fall-related outcome, were included in the scoping review for qualitative synthesis. RESULTS Two articles on cardiovascular diagnostics and eight articles on cardiovascular treatments were included in the evidence map. Six out of ten studies concerned pacemaker intervention of which one meta-analyses that included randomized controlled trials with contradictory results. A combined cardiovascular assessment/evaluation (one study) and pharmacotherapy in orthostatic hypotension (one study) showed fall reducing potential. The scoping review contained 40 articles on cardiovascular diagnostics and one on cardiovascular treatments. It provides an extensive overview of several diagnostics (e.g., orthostatic blood pressure measurements, heart rhythm assessment) useful in fall prevention. Also, diagnostics were identified, that could potentially provide added value in fall prevention (e.g., blood pressure variability and head turning). CONCLUSION Although the majority of studies showed a reduction in falls after the intervention, the total amount of evidence regarding the effect of cardiovascular diagnostics/treatments on falls is small. Our findings can be used to optimize fall prevention strategies and develop an evidence-based fall prevention care pathway. Adhering to the World guidelines on fall prevention recommendations, it is crucial to undertake a standardized assessment of cardiovascular risk factors, followed by supplementary testing and corresponding interventions, as effective components of fall prevention strategies. In addition, accompanying diagnostics such as blood pressure variability and head turning can be of added value.
Collapse
|
3
|
Exploring the potential impact of multi-factor precision interventions in Alzheimer's disease with system dynamics. J Biomed Inform 2023; 145:104462. [PMID: 37516375 DOI: 10.1016/j.jbi.2023.104462] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 06/09/2023] [Accepted: 07/26/2023] [Indexed: 07/31/2023]
Abstract
Numerous clinical trials based on a single-cause paradigm have not resulted in efficacious treatments for Alzheimer's disease (AD). Recently, prevention trials that simultaneously intervened on multiple risk factors have shown mixed results, suggesting that careful design is necessary. Moreover, intensive pilot precision medicine (PM) trial results have been promising but may not generalize to a broader population. These observations suggest that a model-based approach to multi-factor precision medicine (PM) is warranted. We systematically developed a system dynamics model (SDM) of AD for PM using data from two longitudinal studies (N=3660). This method involved a model selection procedure in identifying interaction terms between the SDM components and estimating individualized parameters. We used the SDM to explore simulated single- and double-factor interventions on 14 modifiable risk factors. We quantified the potential impact of double-factor interventions over single-factor interventions as 1.5 [95% CI: 1.5-2.6] and of SDM-based PM over a one-size-fits-all approach as 3.5 [3.1, 3.8] ADAS-cog-13 points in 12 years. Although the model remains to be validated, we tentatively conclude that multi-factor PM could come to play an important role in AD prevention.
Collapse
|
4
|
Applying systems thinking to unravel the mechanisms underlying orthostatic hypotension related fall risk. GeroScience 2023; 45:2743-2755. [PMID: 37115348 PMCID: PMC10651607 DOI: 10.1007/s11357-023-00802-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 04/17/2023] [Indexed: 04/29/2023] Open
Abstract
Orthostatic hypotension (OH) is an established and common cardiovascular risk factor for falls. An in-depth understanding of the various interacting pathophysiological pathways contributing to OH-related falls is essential to guide improvements in diagnostic and treatment opportunities. We applied systems thinking to multidisciplinary map out causal mechanisms and risk factors. For this, we used group model building (GMB) to develop a causal loop diagram (CLD). The GMB was based on the input of experts from multiple domains related to OH and falls and all proposed mechanisms were supported by scientific literature. Our CLD is a conceptual representation of factors involved in OH-related falls, and their interrelatedness. Network analysis and feedback loops were applied to analyze and interpret the CLD, and quantitatively summarize the function and relative importance of the variables. Our CLD contains 50 variables distributed over three intrinsic domains (cerebral, cardiovascular, and musculoskeletal), and an extrinsic domain (e.g., medications). Between the variables, 181 connections and 65 feedback loops were identified. Decreased cerebral blood flow, low blood pressure, impaired baroreflex activity, and physical inactivity were identified as key factors involved in OH-related falls, based on their high centralities. Our CLD reflects the multifactorial pathophysiology of OH-related falls. It enables us to identify key elements, suggesting their potential for new diagnostic and treatment approaches in fall prevention. The interactive online CLD renders it suitable for both research and educational purposes and this CLD is the first step in the development of a computational model for simulating the effects of risk factors on falls.
Collapse
|
5
|
Image-based flow simulation of platelet aggregates under different shear rates. PLoS Comput Biol 2023; 19:e1010965. [PMID: 37428797 PMCID: PMC10358939 DOI: 10.1371/journal.pcbi.1010965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/10/2023] [Indexed: 07/12/2023] Open
Abstract
Hemodynamics is crucial for the activation and aggregation of platelets in response to flow-induced shear. In this paper, a novel image-based computational model simulating blood flow through and around platelet aggregates is presented. The microstructure of aggregates was captured by two different modalities of microscopy images of in vitro whole blood perfusion experiments in microfluidic chambers coated with collagen. One set of images captured the geometry of the aggregate outline, while the other employed platelet labelling to infer the internal density. The platelet aggregates were modelled as a porous medium, the permeability of which was calculated with the Kozeny-Carman equation. The computational model was subsequently applied to study hemodynamics inside and around the platelet aggregates. The blood flow velocity, shear stress and kinetic force exerted on the aggregates were investigated and compared under 800 s-1, 1600 s-1 and 4000 s-1 wall shear rates. The advection-diffusion balance of agonist transport inside the platelet aggregates was also evaluated by local Péclet number. The findings show that the transport of agonists is not only affected by the shear rate but also significantly influenced by the microstructure of the aggregates. Moreover, large kinetic forces were found at the transition zone from shell to core of the aggregates, which could contribute to identifying the boundary between the shell and the core. The shear rate and the rate of elongation flow were investigated as well. The results imply that the emerging shapes of aggregates are highly correlated to the shear rate and the rate of elongation. The framework provides a way to incorporate the internal microstructure of the aggregates into the computational model and yields a better understanding of the hemodynamics and physiology of platelet aggregates, hence laying the foundation for predicting aggregation and deformation under different flow conditions.
Collapse
|
6
|
Simulating the multicausality of Alzheimer's disease with system dynamics. Alzheimers Dement 2023. [PMID: 36794757 DOI: 10.1002/alz.12923] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 11/25/2022] [Accepted: 12/15/2022] [Indexed: 02/17/2023]
Abstract
INTRODUCTION In Alzheimer's disease (AD), cognitive decline is driven by various interlinking causal factors. Systems thinking could help elucidate this multicausality and identify opportune intervention targets. METHODS We developed a system dynamics model (SDM) of sporadic AD with 33 factors and 148 causal links calibrated with empirical data from two studies. We tested the SDM's validity by ranking intervention outcomes on 15 modifiable risk factors to two sets of 44 and 9 validation statements based on meta-analyses of observational data and randomized controlled trials, respectively. RESULTS The SDM answered 77% and 78% of the validation statements correctly. Sleep quality and depressive symptoms yielded the largest effects on cognitive decline with which they were connected through strong reinforcing feedback loops, including via phosphorylated tau burden. DISCUSSION SDMs can be constructed and validated to simulate interventions and gain insight into the relative contribution of mechanistic pathways.
Collapse
|
7
|
Animal models and animal-free innovations for cardiovascular research: current status and routes to be explored. Consensus document of the ESC Working Group on Myocardial Function and the ESC Working Group on Cellular Biology of the Heart. Cardiovasc Res 2022; 118:3016-3051. [PMID: 34999816 PMCID: PMC9732557 DOI: 10.1093/cvr/cvab370] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 01/05/2022] [Indexed: 01/09/2023] Open
Abstract
Cardiovascular diseases represent a major cause of morbidity and mortality, necessitating research to improve diagnostics, and to discover and test novel preventive and curative therapies, all of which warrant experimental models that recapitulate human disease. The translation of basic science results to clinical practice is a challenging task, in particular for complex conditions such as cardiovascular diseases, which often result from multiple risk factors and comorbidities. This difficulty might lead some individuals to question the value of animal research, citing the translational 'valley of death', which largely reflects the fact that studies in rodents are difficult to translate to humans. This is also influenced by the fact that new, human-derived in vitro models can recapitulate aspects of disease processes. However, it would be a mistake to think that animal models do not represent a vital step in the translational pathway as they do provide important pathophysiological insights into disease mechanisms particularly on an organ and systemic level. While stem cell-derived human models have the potential to become key in testing toxicity and effectiveness of new drugs, we need to be realistic, and carefully validate all new human-like disease models. In this position paper, we highlight recent advances in trying to reduce the number of animals for cardiovascular research ranging from stem cell-derived models to in situ modelling of heart properties, bioinformatic models based on large datasets, and state-of-the-art animal models, which show clinically relevant characteristics observed in patients with a cardiovascular disease. We aim to provide a guide to help researchers in their experimental design to translate bench findings to clinical routine taking the replacement, reduction, and refinement (3R) as a guiding concept.
Collapse
Grants
- R01 HL150359 NHLBI NIH HHS
- RG/16/14/32397 British Heart Foundation
- FS/18/37/33642 British Heart Foundation
- PG/17/64/33205 British Heart Foundation
- PG/15/88/31780 British Heart Foundation
- FS/RTF/20/30009, NH/19/1/34595, PG/18/35/33786, CS/17/4/32960, PG/15/88/31780, and PG/17/64/33205 British Heart Foundation
- NC/T001488/1 National Centre for the Replacement, Refinement and Reduction of Animals in Research
- PG/18/44/33790 British Heart Foundation
- CH/16/3/32406 British Heart Foundation
- FS/RTF/20/30009 British Heart Foundation
- NWO-ZonMW
- ZonMW and Heart Foundation for the translational research program
- Dutch Cardiovascular Alliance (DCVA)
- Leducq Foundation
- Dutch Research Council
- Association of Collaborating Health Foundations (SGF)
- UCL Hospitals NIHR Biomedical Research Centre, and the DCVA
- Netherlands CardioVascular Research Initiative CVON
- Stichting Hartekind and the Dutch Research Counsel (NWO) (OCENW.GROOT.2019.029)
- National Fund for Scientific Research, Belgium and Action de Recherche Concertée de la Communauté Wallonie-Bruxelles, Belgium
- Netherlands CardioVascular Research Initiative CVON (PREDICT2 and CONCOR-genes projects), the Leducq Foundation
- ERA PerMed (PROCEED study)
- Netherlands Cardiovascular Research Initiative
- Dutch Heart Foundation
- German Centre of Cardiovascular Research (DZHH)
- Chest Heart and Stroke Scotland
- Tenovus Scotland
- Friends of Anchor and Grampian NHS-Endowments
- National Institute for Health Research University College London Hospitals Biomedical Research Centre
- German Centre for Cardiovascular Research
- European Research Council (ERC-AG IndivuHeart), the Deutsche Forschungsgemeinschaft
- European Union Horizon 2020 (REANIMA and TRAINHEART)
- German Ministry of Education and Research (BMBF)
- Centre for Cardiovascular Research (DZHK)
- European Union Horizon 2020
- DFG
- National Research, Development and Innovation Office of Hungary
- Research Excellence Program—TKP; National Heart Program
- Austrian Science Fund
- European Union Commission’s Seventh Framework programme
- CVON2016-Early HFPEF
- CVON She-PREDICTS
- CVON Arena-PRIME
- European Union’s Horizon 2020 research and innovation programme
- Deutsche Forschungsgemeinschaft
- Volkswagenstiftung
- French National Research Agency
- ERA-Net-CVD
- Fédération Française de Cardiologie, the Fondation pour la Recherche Médicale
- French PIA Project
- University Research Federation against heart failure
- Netherlands Heart Foundation
- Dekker Senior Clinical Scientist
- Health Holland TKI-LSH
- TUe/UMCU/UU Alliance Fund
- south African National Foundation
- Cancer Association of South Africa and Winetech
- Netherlands Heart Foundation/Applied & Engineering Sciences
- Dutch Technology Foundation
- Pie Medical Imaging
- Netherlands Organisation for Scientific Research
- Dr. Dekker Program
- Netherlands CardioVascular Research Initiative: the Dutch Heart Foundation
- Dutch Federation of University Medical Centres
- Netherlands Organization for Health Research and Development and the Royal Netherlands Academy of Sciences for the GENIUS-II project
- Netherlands Organization for Scientific Research (NWO) (VICI grant); the European Research Council
- Incyte s.r.l. and from Ministero dell’Istruzione, Università e Ricerca Scientifica
- German Center for Cardiovascular Research (Junior Research Group & Translational Research Project), the European Research Council (ERC Starting Grant NORVAS),
- Swedish Heart-Lung-Foundation
- Swedish Research Council
- National Institutes of Health
- Bavarian State Ministry of Health and Care through the research project DigiMed Bayern
- ERC
- ERA-CVD
- Dutch Heart Foundation, ZonMw
- the NWO Gravitation project
- Ministero dell'Istruzione, Università e Ricerca Scientifica
- Regione Lombardia
- Netherlands Organisation for Health Research and Development
- ITN Network Personalize AF: Personalized Therapies for Atrial Fibrillation: a translational network
- MAESTRIA: Machine Learning Artificial Intelligence Early Detection Stroke Atrial Fibrillation
- REPAIR: Restoring cardiac mechanical function by polymeric artificial muscular tissue
- Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)
- European Union H2020 program to the project TECHNOBEAT
- EVICARE
- BRAV3
- ZonMw
- German Centre for Cardiovascular Research (DZHK)
- British Heart Foundation Centre for Cardiac Regeneration
- British Heart Foundation studentship
- NC3Rs
- Interreg ITA-AUS project InCARDIO
- Italian Association for Cancer Research
Collapse
|
8
|
Modelling collateral flow and thrombus permeability during acute ischaemic stroke. J R Soc Interface 2022; 19:20220649. [PMID: 36195117 PMCID: PMC9532024 DOI: 10.1098/rsif.2022.0649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The presence of collaterals and high thrombus permeability are associated with good functional outcomes after an acute ischaemic stroke. We aim to understand the combined effect of the collaterals and thrombus permeability on cerebral blood flow during an acute ischaemic stroke. A cerebral blood flow model including the leptomeningeal collateral circulation is used to simulate cerebral blood flow during an acute ischaemic stroke. The collateral circulation is varied to capture the collateral scores: absent, poor, moderate and good. Measurements of the transit time, void fraction and thrombus length in acute ischaemic stroke patients are used to estimate thrombus permeability. Estimated thrombus permeability ranges between 10-7 and 10-4 mm2. Measured flow rates through the thrombus are small and the effect of a permeable thrombus on brain perfusion during stroke is small compared with the effect of collaterals. Our simulations suggest that the collaterals are a dominant factor in the resulting infarct volume after a stroke.
Collapse
|
9
|
Impact of cardiovascular evaluations and interventions on fall risk in older adults: a protocol for a scoping review and evidence map. BMJ Open 2022; 12:e057959. [PMID: 35443960 PMCID: PMC9021776 DOI: 10.1136/bmjopen-2021-057959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION Cardiovascular disorders are increasingly recognised as important fall risk factors in older adults. Falls are a major public health problem in older adults, and therefore, effective interventions for reducing falls are essential for this population. Cardiovascular disease is a clinically relevant (but often overlooked) and potentially modifiable risk factor for falls. Literature describing the effects of cardiovascular assessments and treatments on fall prevention has generally focused on only one specific test or treatment. A comprehensive, comparative overview surrounding the effectiveness of available assessments and treatments on cardiovascular related fall risk is currently lacking. METHODS AND ANALYSIS A scoping review and evidence map will be conducted to summarise the available evidence regarding the (comparative) effectiveness of cardiovascular assessments and therapeutic interventions on reducing fall risk in older individuals. A systematic and comprehensive literature search will be performed in MEDLINE and Embase using the key components 'older adults', 'cardiovascular evaluation', 'cardiovascular intervention' and 'falls'. Furthermore, we will create an evidence map to summarise the quantity and quality of currently available evidence identified in the scoping review. The evidence map will consider, but will not be limited to, observational studies, randomised controlled trials and reviews evaluating cardiovascular tests and treatments (vs controls) on fall risk in older adults. ETHICS AND DISSEMINATION The scoping review and evidence map will only include data that are publicly available and, therefore, ethical approval is not required. The results will be submitted for publication in a peer-reviewed journal and presented at scientific conferences.
Collapse
|
10
|
Uncertainty quantification of a three-dimensional in-stent restenosis model with surrogate modelling. J R Soc Interface 2022; 19:20210864. [PMID: 35193385 PMCID: PMC8867271 DOI: 10.1098/rsif.2021.0864] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
In-stent restenosis is a recurrence of coronary artery narrowing due to vascular injury caused by balloon dilation and stent placement. It may lead to the relapse of angina symptoms or to an acute coronary syndrome. An uncertainty quantification of a model for in-stent restenosis with four uncertain parameters (endothelium regeneration time, the threshold strain for smooth muscle cell bond breaking, blood flow velocity and the percentage of fenestration in the internal elastic lamina) is presented. Two quantities of interest were studied, namely the average cross-sectional area and the maximum relative area loss in a vessel. Owing to the high computational cost required for uncertainty quantification, a surrogate model, based on Gaussian process regression with proper orthogonal decomposition, was developed and subsequently used for model response evaluation in the uncertainty quantification. A detailed analysis of the uncertainty propagation is presented. Around 11% and 16% uncertainty is observed on the two quantities of interest, respectively, and the uncertainty estimates show that a higher fenestration mainly determines the uncertainty in the neointimal growth at the initial stage of the process. The uncertainties in blood flow velocity and endothelium regeneration time mainly determine the uncertainty in the quantities of interest at the later, clinically relevant stages of the restenosis process.
Collapse
|
11
|
The Effects of Micro-vessel Curvature Induced Elongational Flows on Platelet Adhesion. Ann Biomed Eng 2021; 49:3609-3620. [PMID: 34668098 PMCID: PMC8671278 DOI: 10.1007/s10439-021-02870-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 09/28/2021] [Indexed: 11/29/2022]
Abstract
The emerging profile of blood flow and the cross-sectional distribution of blood cells have far reaching biological consequences in various diseases and vital internal processes, such as platelet adhesion. The effects of several essential blood flow parameters, such as red blood cell free layer width, wall shear rate, and hematocrit on platelet adhesion were previously explored to great lengths in straight geometries. In the current work, the effects of channel curvature on cellular blood flow are investigated by simulating the accurate cellular movement and interaction of red blood cells and platelets in a half-arc channel for multiple wall shear rate and hematocrit values. The results show significant differences in the emerging shear rate values and distributions between the inner and outer arc of the channel curve, while the cell distributions remain predominantly uninfluenced. The simulation predictions are also compared to experimental platelet adhesion in a similar curved geometry. The inner side of the arc shows elevated platelet adhesion intensity at high wall shear rate, which correlates with increased shear rate and shear rate gradient sites in the simulation. Furthermore, since the platelet availability for binding seems uninfluenced by the curvature, these effects might influence the binding mechanics rather than the probability. The presence of elongational flows is detected in the simulations and the link to increased platelet adhesion is discussed in the experimental results.
Collapse
|
12
|
On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation. Ann Biomed Eng 2021; 49:3647-3665. [PMID: 34155569 PMCID: PMC8671295 DOI: 10.1007/s10439-021-02808-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 06/01/2021] [Indexed: 11/08/2022]
Abstract
Computational physiological models are promising tools to enhance the design of clinical trials and to assist in decision making. Organ-scale haemodynamic models are gaining popularity to evaluate perfusion in a virtual environment both in healthy and diseased patients. Recently, the principles of verification, validation, and uncertainty quantification of such physiological models have been laid down to ensure safe applications of engineering software in the medical device industry. The present study sets out to establish guidelines for the usage of a three-dimensional steady state porous cerebral perfusion model of the human brain following principles detailed in the verification and validation (V&V 40) standard of the American Society of Mechanical Engineers. The model relies on the finite element method and has been developed specifically to estimate how brain perfusion is altered in ischaemic stroke patients before, during, and after treatments. Simulations are compared with exact analytical solutions and a thorough sensitivity analysis is presented covering every numerical and physiological model parameter. The results suggest that such porous models can approximate blood pressure and perfusion distributions reliably even on a coarse grid with first order elements. On the other hand, higher order elements are essential to mitigate errors in volumetric blood flow rate estimation through cortical surface regions. Matching the volumetric flow rate corresponding to major cerebral arteries is identified as a validation milestone. It is found that inlet velocity boundary conditions are hard to obtain and that constant pressure inlet boundary conditions are feasible alternatives. A one-dimensional model is presented which can serve as a computationally inexpensive replacement of the three-dimensional brain model to ease parameter optimisation, sensitivity analyses and uncertainty quantification. The findings of the present study can be generalised to organ-scale porous perfusion models. The results increase the applicability of computational tools regarding treatment development for stroke and other cerebrovascular conditions.
Collapse
|
13
|
Reliability and reproducibility in computational science: implementing validation, verification and uncertainty quantification in silico. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200409. [PMID: 33775138 DOI: 10.1098/rsta.2020.0409] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/06/2021] [Indexed: 06/12/2023]
|
14
|
Modelling the leptomeningeal collateral circulation during acute ischaemic stroke. Med Eng Phys 2021; 91:1-11. [PMID: 34074460 DOI: 10.1016/j.medengphy.2021.03.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/26/2021] [Accepted: 03/10/2021] [Indexed: 10/21/2022]
Abstract
A novel model of the leptomeningeal collateral circulation is created by combining data from multiple sources with statistical scaling laws. The extent of the collateral circulation is varied by defining a collateral vessel probability. Blood flow and pressure are simulated using a one-dimensional steady state blood flow model. The leptomeningeal collateral vessels provide significant flow during a stroke. The pressure drop over an occlusion predicted by the model ranges between 60 and 85 mmHg depending on the extent of the collateral circulation. The linear transport of contrast material was simulated in the circulatory network. The time delay of peak contrast over an occlusion is 3.3 s in the model, and 2.1 s (IQR 0.8-4.0 s) when measured in dynamic CTA data of acute ischaemic stroke patients. Modelling the leptomeningeal collateral circulation could lead to better estimates of infarct volume and patient outcome.
Collapse
|
15
|
Coupling one-dimensional arterial blood flow to three-dimensional tissue perfusion models for in silico trials of acute ischaemic stroke. Interface Focus 2021; 11:20190125. [PMID: 33335706 PMCID: PMC7739918 DOI: 10.1098/rsfs.2019.0125] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/23/2020] [Indexed: 01/08/2023] Open
Abstract
An acute ischaemic stroke is due to the sudden blockage of an intracranial blood vessel by an embolized thrombus. In the context of setting up in silico trials for the treatment of acute ischaemic stroke, the effect of a stroke on perfusion and metabolism of brain tissue should be modelled to predict final infarcted brain tissue. This requires coupling of blood flow and tissue perfusion models. A one-dimensional intracranial blood flow model and a method to couple this to a brain tissue perfusion model for patient-specific simulations is presented. Image-based patient-specific data on the anatomy of the circle of Willis are combined with literature data and models for vessel anatomy not visible in the images, to create an extended model for each patient from the larger vessels down to the pial surface. The coupling between arterial blood flow and tissue perfusion occurs at the pial surface through the estimation of perfusion territories. The coupling method is able to accurately estimate perfusion territories. Finally, we argue that blood flow can be approximated as steady-state flow at the interface between arterial blood flow and tissue perfusion to reduce the cost of organ-scale simulations.
Collapse
|
16
|
Haemodynamic flow conditions at the initiation of high-shear platelet aggregation: a combined in vitro and cellular in silico study. Interface Focus 2021; 11:20190126. [PMID: 33335707 PMCID: PMC7739908 DOI: 10.1098/rsfs.2019.0126] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/03/2020] [Indexed: 12/11/2022] Open
Abstract
The influence of the flow environment on platelet aggregation is not fully understood in high-shear thrombosis. The objective of this study is to investigate the role of a high shear rate in initial platelet aggregation. The haemodynamic conditions in a microfluidic device are studied using cell-based blood flow simulations. The results are compared with in vitro platelet aggregation experiments performed with porcine whole blood (WB) and platelet-rich-plasma (PRP). We studied whether the cell-depleted layer in combination with high shear and high platelet flux can account for the distribution of platelet aggregates. High platelet fluxes at the wall were found in silico. In WB, the platelet flux was about twice as high as in PRP. Additionally, initial platelet aggregation and occlusion were observed in vitro in the stenotic region. In PRP, the position of the occlusive thrombus was located more downstream than in WB. Furthermore, the shear rates and stresses in cell-based and continuum simulations were studied. We found that a continuum simulation is a good approximation for PRP. For WB, it cannot predict the correct values near the wall.
Collapse
|
17
|
Mapping the multicausality of Alzheimer's disease through group model building. GeroScience 2020; 43:829-843. [PMID: 32780293 PMCID: PMC8110634 DOI: 10.1007/s11357-020-00228-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/06/2020] [Indexed: 12/02/2022] Open
Abstract
Alzheimer’s disease (AD) is a complex, multicausal disorder involving several spatiotemporal scales and scientific domains. While many studies focus on specific parts of this system, the complexity of AD is rarely studied as a whole. In this work, we apply systems thinking to map out known causal mechanisms and risk factors ranging from intracellular to psychosocial scales in sporadic AD. We report on the first systemic causal loop diagram (CLD) for AD, which is the result of an interdisciplinary group model building (GMB) process. The GMB was based on the input of experts from multiple domains and all proposed mechanisms were supported by scientific literature. The CLD elucidates interaction and feedback mechanisms that contribute to cognitive decline from midlife onward as described by the experts. As an immediate outcome, we observed several non-trivial reinforcing feedback loops involving factors at multiple spatial scales, which are rarely considered within the same theoretical framework. We also observed high centrality for modifiable risk factors such as social relationships and physical activity, which suggests they may be promising leverage points for interventions. This illustrates how a CLD from an interdisciplinary GMB process may lead to novel insights into complex disorders. Furthermore, the CLD is the first step in the development of a computational model for simulating the effects of risk factors on AD.
Collapse
|
18
|
Redistribution of TPA Fluxes in the Presence of PAI-1 Regulates Spatial Thrombolysis. Biophys J 2020; 119:638-651. [PMID: 32653051 DOI: 10.1016/j.bpj.2020.06.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 06/10/2020] [Accepted: 06/16/2020] [Indexed: 12/18/2022] Open
Abstract
The fibrin clot is gelatinous matter formed upon injury to stop blood loss and is later destroyed by fibrinolysis, an enzymatic cascade with feedback. Pharmacological fibrinolysis stimulation is also used to destroy pathological, life-threatening clots and thrombi (thrombolysis). The regulation of the nonlinear spatially nonuniform fibrinolytic process in thrombolysis is not currently well understood. We developed a reaction-diffusion-advection model of thrombolysis by tissue plasminogen activator (TPA) in an occluded vessel with a pressure gradient. Sensitivity-analysis-based model reduction was used to reveal the critical processes controlling different steps of thrombolysis. The propagation of thrombolysis in the system without flow was predominantly controlled by TPA diffusion, whereas transport of other active components was rendered nonessential either by their high fibrin-binding parameters and short lifetimes or their initial uniform distribution. The concentration of the main TPA inhibitor plasminogen activator inhibitor 1 (PAI-1) controlled both the extent of lysis propagation and the shape of fibrin spatial distribution during lysis. Interestingly, PAI-1 remained important even when its concentration was an order of magnitude below that of TPA because of its role at the edge of the diffusing TPA front. The system was robust to reaction rate constant perturbations. Using these data, a reduced model of thrombolysis was proposed. In the presence of flow, convection of TPA was the critical controlling process; although the role of PAI-1 concentration was much less in the presence of flow, its influence became greater in the presence of collateral bypassing vessels, which sufficiently reduced TPA flux through the thrombus. Flow bypass through the collateral vessel caused a decrease in TPA flux in the clotted vessel, which increased the PAI-1/TPA ratio, thus making PAI-1-induced inhibition relevant for the regulation of spatial lysis up to its arrest.
Collapse
|
19
|
A particle-based model for endothelial cell migration under flow conditions. Biomech Model Mechanobiol 2019; 19:681-692. [PMID: 31624966 PMCID: PMC7105450 DOI: 10.1007/s10237-019-01239-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 10/09/2019] [Indexed: 11/30/2022]
Abstract
Endothelial cells (ECs) play a major role in the healing process following angioplasty to inhibit excessive neointima. This makes the process of EC healing after injury, in particular EC migration in a stented vessel, important for recovery of normal vessel function. In that context, we present a novel particle-based model of EC migration and validate it against in vitro experimental data. We have developed a particle-based model of EC migration under flow conditions in an in vitro vessel with obstacles. Cell movement in the model is a combination of random walks and directed movement along the local flow velocity vector. For model calibration, a set of experimental data for cell migration in a similarly shaped channel has been used. We have calibrated the model for a baseline case of a channel with no obstacles and then applied it to the case of a channel with ridges on the bottom surface, representative of stent strut geometry. We were able to closely reproduce the cell migration speed and angular distribution of their movement relative to the flow direction reported in vitro. The model also reproduces qualitative aspects of EC migration, such as entrapment of cells downstream from the flow-disturbing ridge. The model has the potential, after more extensive in vitro validation, to study the effect of variation in strut spacing and shape, through modification of the local flow, on EC migration. The results of this study support the hypothesis that EC migration is strongly affected by the direction and magnitude of local wall shear stress.
Collapse
|
20
|
Abstract
Computer simulations were performed to study the transport of red blood cells and platelets in high shear flows, mimicking earlier published in vitro experiments in microfluidic devices with high affinity for platelet aggregate formation. The goal is to understand and predict where thrombus formation starts. Additionally, the need of cell-based modelling in these microfluidic devices is demonstrated by comparing our results with macroscopic models, wherein blood is modelled as a continuous fluid. Hemocell, a cell-based blood flow simulation framework is used to investigate the transport physics in the microfluidic devices. The simulations show an enlarged cell-depleted layer at the site where a platelet aggregate forms in the experiments. In this enlarged cell-depleted layer, the probability to find a platelet is higher than in the rest of the microfluidic device. In addition, the shear rates are sufficiently high to allow for the von Willebrand factor to elongate in this region. We hypothesize that the enlarged cell-depleted layer combined with a sufficiently large platelet flux and sufficiently high shear rates result in an haemodynamic environment that is a preferred location for initial platelet aggregation.
Collapse
|
21
|
Location-Specific Comparison Between a 3D In-Stent Restenosis Model and Micro-CT and Histology Data from Porcine In Vivo Experiments. Cardiovasc Eng Technol 2019; 10:568-582. [PMID: 31531821 PMCID: PMC6863796 DOI: 10.1007/s13239-019-00431-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 09/07/2019] [Indexed: 11/25/2022]
Abstract
Background Coronary artery restenosis is an important side effect of percutaneous coronary intervention. Computational models can be used to better understand this process. We report on an approach for validation of an in silico 3D model of in-stent restenosis in porcine coronary arteries and illustrate this approach by comparing the modelling results to in vivo data for 14 and 28 days post-stenting. Methods This multiscale model includes single-scale models for stent deployment, blood flow and tissue growth in the stented vessel, including smooth muscle cell (SMC) proliferation and extracellular matrix (ECM) production. The validation procedure uses data from porcine in vivo experiments, by simulating stent deployment using stent geometry obtained from micro computed tomography (micro-CT) of the stented vessel and directly comparing the simulation results of neointimal growth to histological sections taken at the same locations. Results Metrics for comparison are per-strut neointimal thickness and per-section neointimal area. The neointimal area predicted by the model demonstrates a good agreement with the detailed experimental data. For 14 days post-stenting the relative neointimal area, averaged over all vessel sections considered, was 20 ± 3% in vivo and 22 ± 4% in silico. For 28 days, the area was 42 ± 3% in vivo and 41 ± 3% in silico. Conclusions The approach presented here provides a very detailed, location-specific, validation methodology for in silico restenosis models. The model was able to closely match both histology datasets with a single set of parameters. Good agreement was obtained for both the overall amount of neointima produced and the local distribution. It should be noted that including vessel curvature and ECM production in the model was paramount to obtain a good agreement with the experimental data. Electronic supplementary material The online version of this article (10.1007/s13239-019-00431-4) contains supplementary material, which is available to authorized users.
Collapse
|
22
|
[Complexity of disease; a modern view in times of ageing populations and multimorbidity]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2019; 163:D3970. [PMID: 31433143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Complexity of patient care is rapidly increasing as a consequence of rising numbers of patients with complex multimorbidity. Not just the patient as a whole, but also the networks of organs, tissues and cells are forming a complex adaptive system (CAS). A CAS is defined as a network of several components ('agents') with lots of mutual feedback loops between which there are circular causalities; the predictability of a CAS is limited by definition. However, current guidelines and evidence-based medicine assume that diseases and the medical interventions to address them are predictable. Physicians' brains are complex neural networks that are much better at dealing with complex situations than guidelines. In the near future, physicians will also get help from advanced computer simulation models that make better diagnostic analyses on the basis of detailed phenotyping and are more accurate when predicting possible courses of disease and treatment outcomes.
Collapse
|
23
|
Multiscale modelling, simulation and computing: from the desktop to the exascale. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2019; 377:20180355. [PMID: 30967039 PMCID: PMC6388007 DOI: 10.1098/rsta.2018.0355] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 12/11/2018] [Indexed: 05/02/2023]
Abstract
This short contribution introduces a theme issue dedicated to 'Multiscale modelling, simulation and computing: from the desktop to the exascale'. It holds a collection of articles presenting cutting-edge research in generic multiscale modelling and multiscale computing, and applications thereof on high-performance computing systems. The special issue starts with a position paper to discuss the paradigm of multiscale computing in the face of the emerging exascale, followed by a review and critical assessment of existing multiscale computing environments. This theme issue provides a state-of-the-art account of generic multiscale computing, as well as exciting examples of applications of such concepts in domains ranging from astrophysics, via material science and fusion, to biomedical sciences. This article is part of the theme issue 'Multiscale modelling, simulation and computing: from the desktop to the exascale'.
Collapse
|
24
|
Multiscale computing for science and engineering in the era of exascale performance. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2019; 377:20180144. [PMID: 30967040 PMCID: PMC6388008 DOI: 10.1098/rsta.2018.0144] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 10/09/2018] [Indexed: 05/18/2023]
Abstract
In this position paper, we discuss two relevant topics: (i) generic multiscale computing on emerging exascale high-performing computing environments, and (ii) the scaling of such applications towards the exascale. We will introduce the different phases when developing a multiscale model and simulating it on available computing infrastructure, and argue that we could rely on it both on the conceptual modelling level and also when actually executing the multiscale simulation, and maybe should further develop generic frameworks and software tools to facilitate multiscale computing. Next, we focus on simulating multiscale models on high-end computing resources in the face of emerging exascale performance levels. We will argue that although applications could scale to exascale performance relying on weak scaling and maybe even on strong scaling, there are also clear arguments that such scaling may no longer apply for many applications on these emerging exascale machines and that we need to resort to what we would call multi-scaling. This article is part of the theme issue 'Multiscale modelling, simulation and computing: from the desktop to the exascale'.
Collapse
|
25
|
Cell-resolved blood flow simulations of saccular aneurysms: effects of pulsatility and aspect ratio. J R Soc Interface 2018; 15:rsif.2018.0485. [PMID: 30257923 DOI: 10.1098/rsif.2018.0485] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 08/28/2018] [Indexed: 11/12/2022] Open
Abstract
We study the effect of pulsatile flow on the transport of red blood cells (RBCs) and platelets into aneurysm geometries with varying dome-to-neck aspect ratios (AR). We use a validated two-dimensional lattice Boltzmann model for blood plasma with a discrete element method for both RBCs and platelets coupled by the immersed boundary method. Flow velocities and vessel diameters were matched with measurements of cerebral perforating arteries and flow was driven by a synthetic heartbeat curve typical for such vessel sizes. We observe a flow regime change as the aspect ratio increases from a momentum-driven regime in the small aspect ratio to a shear-driven regime in the larger aspect ratios. In the small aspect ratio case, we see the development of a re-circulation zone that exhibits a layering of high (greater than or equal to 7 s) and low (less than 7 s) residence cells. In the shear-driven regime, we see high and low residence cells well mixed, with an increasing population of cells that are trapped inside the aneurysm as the aspect ratio increases. In all cases, we observe aneurysms that are platelet-rich and red blood cell-poor when compared with their respective parental vessel populations. Pulsatility also plays a role in the small aspect ratio as we observe a smaller population of older trapped cells along the aneurysm wall in the pulsatile case when compared with a steady flow case. Pulsatility does not have a significant effect in shear-driven regime aspect ratios.
Collapse
|
26
|
Uncertainty Quantification of a Multiscale Model for In-Stent Restenosis. Cardiovasc Eng Technol 2018; 9:761-774. [PMID: 30136082 PMCID: PMC6290695 DOI: 10.1007/s13239-018-00372-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 08/09/2018] [Indexed: 12/11/2022]
Abstract
Purpose Coronary artery stenosis, or abnormal narrowing, is a widespread and potentially fatal cardiac disease. After treatment by balloon angioplasty and stenting, restenosis may occur inside the stent due to excessive neointima formation. Simulations of in-stent restenosis can provide new insight into this process. However, uncertainties due to variability in patient-specific parameters must be taken into account. Methods We performed an uncertainty quantification (UQ) study on a complex two-dimensional in-stent restenosis model. We used a quasi-Monte Carlo method for UQ of the neointimal area, and the Sobol sensitivity analysis (SA) to estimate the proportions of aleatory and epistemic uncertainties and to determine the most important input parameters. Results We observe approximately 30% uncertainty in the mean neointimal area as simulated by the model. Depending on whether a fast initial endothelium recovery occurs, the proportion of the model variance due to natural variability ranges from 15 to 35%. The endothelium regeneration time is identified as the most influential model parameter. Conclusion The model output contains a moderate quantity of uncertainty, and the model precision can be increased by obtaining a more certain value on the endothelium regeneration time. We conclude that the quasi-Monte Carlo UQ and the Sobol SA are reliable methods for estimating uncertainties in the response of complicated multiscale cardiovascular models.
Collapse
|
27
|
A cell-based mechanical model of coronary artery tunica media. J R Soc Interface 2018; 14:rsif.2017.0028. [PMID: 28679664 DOI: 10.1098/rsif.2017.0028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 06/05/2017] [Indexed: 12/23/2022] Open
Abstract
A three-dimensional cell-based mechanical model of coronary artery tunica media is proposed. The model is composed of spherical cells forming a hexagonal close-packed lattice. Tissue anisotropy is taken into account by varying interaction forces with the direction of intercellular connection. Several cell-centre interaction potentials for repulsion and attraction are considered, including the Hertz contact model and its neo-Hookean extension, the Johnson-Kendall-Roberts model of adhesive contact, and a wormlike chain model. The model is validated against data from in vitro uni-axial tension tests performed on dissected strips of tunica media. The wormlike chain potential in combination with the neo-Hookean Hertz contact model produces stress-stretch curves which represent the experimental data very well.
Collapse
|
28
|
Virtual physiological human 2016: translating the virtual physiological human to the clinic. Interface Focus 2017. [DOI: 10.1098/rsfs.2017.0067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
|
29
|
Revisiting the use of the immersed-boundary lattice-Boltzmann method for simulations of suspended particles. Phys Rev E 2017; 96:013302. [PMID: 29347057 DOI: 10.1103/physreve.96.013302] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Indexed: 06/07/2023]
Abstract
The immersed-boundary lattice-Boltzmann method (IB-LBM) is increasingly being used in simulations of dense suspensions. These systems are computationally very expensive and can strongly benefit from lower resolutions that still maintain the desired accuracy for the quantities of interest. IB-LBM has a number of free parameters that have to be defined, often without exact knowledge of the tradeoffs, since their behavior in low resolutions is not well understood. Such parameters are the lattice constant Δx, the number of vertices N_{v}, the interpolation kernel ϕ, and the LBM relaxation time τ. We investigate the effect of these IB-LBM parameters on a number of straightforward but challenging benchmarks. The systems considered are (a) the flow of a single sphere in shear flow, (b) the collision of two spheres in shear flow, and (c) the lubrication interaction of two spheres. All benchmarks are performed in three dimensions. The first two systems are used for determining two effective radii: the hydrodynamic radius r_{hyd} and the particle interaction radius r_{inter}. The last system is used to establish the numerical robustness of the lubrication forces, used to probe the hydrodynamic interactions in the limit of small gaps. Our results show that lower spatial resolutions result in larger hydrodynamic and interaction radii, while surface densities should be chosen above two vertices per LU^{2} result to prevent fluid penetration in underresolved meshes. Underresolved meshes also failed to produce the migration of particles toward the center of the domain due to lift forces in Couette flow, mostly noticeable for IBM-kernel ϕ_{2}. Kernel ϕ_{4}, despite being more robust toward mesh resolution, produces a notable membrane thickness, leading to the breakdown of the lubrication forces in larger gaps, and its use in dense suspensions where the mean particle distances are small can result in undesired behavior. r_{hyd} is measured to be different from r_{inter}, suggesting that there is no consistent measure to recalibrate the radius of the suspended particle.
Collapse
|
30
|
A Comparison of Fully-Coupled 3D In-Stent Restenosis Simulations to In-vivo Data. Front Physiol 2017; 8:284. [PMID: 28588498 PMCID: PMC5440556 DOI: 10.3389/fphys.2017.00284] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 04/19/2017] [Indexed: 01/05/2023] Open
Abstract
We describe our fully-coupled 3D multiscale model of in-stent restenosis, with blood flow simulations coupled to smooth muscle cell proliferation, and report results of numerical simulations performed with this model. This novel model is based on several previously reported 2D models. We study the effects of various parameters on the process of restenosis and compare with in vivo porcine data where we observe good qualitative agreement. We study the effects of stent deployment depth (and related injury score), reendothelization speed, and simulate the effect of stent width. Also we demonstrate that we are now capable to simulate restenosis in real-sized (18 mm long, 2.8 mm wide) vessel geometries.
Collapse
|
31
|
A physical description of the adhesion and aggregation of platelets. ROYAL SOCIETY OPEN SCIENCE 2017; 4:170219. [PMID: 28484643 PMCID: PMC5414280 DOI: 10.1098/rsos.170219] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 03/13/2017] [Indexed: 06/07/2023]
Abstract
The early stages of clot formation in blood vessels involve platelet adhesion-aggregation. Although these mechanisms have been extensively studied, gaps in their understanding still persist. We have performed detailed in vitro experiments, using the well-known Impact-R device, and developed a numerical model to better describe and understand this phenomenon. Unlike previous studies, we took into account the differential role of pre-activated and non-activated platelets, as well as the three-dimensional nature of the aggregation process. Our investigation reveals that blood albumin is a major parameter limiting platelet aggregate formation in our experiment. Simulations are in very good agreement with observations and provide quantitative estimates of the adhesion and aggregation rates that are hard to measure experimentally. They also provide a value of the effective diffusion of platelets in blood subject to the shear rate produced by the Impact-R.
Collapse
|
32
|
Towards the virtual artery: a multiscale model for vascular physiology at the physics-chemistry-biology interface. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2016; 374:rsta.2016.0146. [PMID: 27698036 PMCID: PMC5052730 DOI: 10.1098/rsta.2016.0146] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 07/14/2016] [Indexed: 05/27/2023]
Abstract
This discussion paper introduces the concept of the Virtual Artery as a multiscale model for arterial physiology and pathologies at the physics-chemistry-biology (PCB) interface. The cellular level is identified as the mesoscopic level, and we argue that by coupling cell-based models with other relevant models on the macro- and microscale, a versatile model of arterial health and disease can be composed. We review the necessary ingredients, both models of arteries at many different scales, as well as generic methods to compose multiscale models. Next, we discuss how this can be combined into the virtual artery. Finally, we argue that the concept of models at the PCB interface could or perhaps should become a powerful paradigm, not only as in our case for studying physiology, but also for many other systems that have such PCB interfaces.This article is part of the themed issue 'Multiscale modelling at the physics-chemistry-biology interface'.
Collapse
|
33
|
Abstract
The Fisher information matrix (FIM) is a widely used measure for applications including statistical inference, information geometry, experiment design, and the study of criticality in biological systems. The FIM is defined for a parametric family of probability distributions and its estimation from data follows one of two paths: either the distribution is assumed to be known and the parameters are estimated from the data or the parameters are known and the distribution is estimated from the data. We consider the latter case which is applicable, for example, to experiments where the parameters are controlled by the experimenter and a complicated relation exists between the input parameters and the resulting distribution of the data. Since we assume that the distribution is unknown, we use a nonparametric density estimation on the data and then compute the FIM directly from that estimate using a finite-difference approximation to estimate the derivatives in its definition. The accuracy of the estimate depends on both the method of nonparametric estimation and the difference Δθ between the densities used in the finite-difference formula. We develop an approach for choosing the optimal parameter difference Δθ based on large deviations theory and compare two nonparametric density estimation methods, the Gaussian kernel density estimator and a novel density estimation using field theory method. We also compare these two methods to a recently published approach that circumvents the need for density estimation by estimating a nonparametric f divergence and using it to approximate the FIM. We use the Fisher information of the normal distribution to validate our method and as a more involved example we compute the temperature component of the FIM in the two-dimensional Ising model and show that it obeys the expected relation to the heat capacity and therefore peaks at the phase transition at the correct critical temperature.
Collapse
|
34
|
An in silico study on the role of smooth muscle cell migration in neointimal formation after coronary stenting. J R Soc Interface 2016; 12:20150358. [PMID: 26063828 DOI: 10.1098/rsif.2015.0358] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Excessive migration and proliferation of smooth muscle cells (SMCs) has been observed as a major factor contributing to the development of in-stent restenosis after coronary stenting. Building upon the results from in vivo experiments, we formulated a hypothesis that the speed of the initial tissue re-growth response is determined by the early migration of SMCs from the injured intima. To test this hypothesis, a cellular Potts model of the stented artery is developed where stent struts were deployed at different depths into the tissue. An extreme scenario with a ruptured internal elastic lamina was also considered to study the role of severe injury in tissue re-growth. Based on the outcomes, we hypothesize that a deeper stent deployment results in on average larger fenestrae in the elastic lamina, allowing easier migration of SMCs into the lumen. The data also suggest that growth of the neointimal lesions owing to SMC proliferation is strongly dependent on the initial number of migrated cells, which form an initial condition for the later phase of the vascular repair. This mechanism could explain the in vivo observation that the initial rate of neointima formation and injury score are strongly correlated.
Collapse
|
35
|
Abstract
Systems medicine is the application of systems biology concepts, methods, and tools to medical research and practice. It aims to integrate data and knowledge from different disciplines into biomedical models and simulations for the understanding, prevention, cure, and management of complex diseases. Complex diseases arise from the interactions among disease-influencing factors across multiple levels of biological organization from the environment to molecules. To tackle the enormous challenges posed by complex diseases, we need a modeling and simulation framework capable of capturing and integrating information originating from multiple spatiotemporal and organizational scales. Multiscale modeling and simulation in systems medicine is an emerging methodology and discipline that has already demonstrated its potential in becoming this framework. The aim of this chapter is to present some of the main concepts, requirements, and challenges of multiscale modeling and simulation in systems medicine.
Collapse
|
36
|
Convergence of the discrete dipole approximation. I. Theoretical analysis: erratum. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2015; 32:2407-2408. [PMID: 26831394 DOI: 10.1364/josaa.32.002407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We report and address the errors in the analysis of the weighted discretization in Section 2.F of our published paper [J. Opt. Soc. Am. A23, 2578 (2006)JOAOD61084-752910.1364/JOSAA.23.002578].
Collapse
|
37
|
Performance of distributed multiscale simulations. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2014; 372:rsta.2013.0407. [PMID: 24982258 PMCID: PMC4084531 DOI: 10.1098/rsta.2013.0407] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Multiscale simulations model phenomena across natural scales using monolithic or component-based code, running on local or distributed resources. In this work, we investigate the performance of distributed multiscale computing of component-based models, guided by six multiscale applications with different characteristics and from several disciplines. Three modes of distributed multiscale computing are identified: supplementing local dependencies with large-scale resources, load distribution over multiple resources, and load balancing of small- and large-scale resources. We find that the first mode has the apparent benefit of increasing simulation speed, and the second mode can increase simulation speed if local resources are limited. Depending on resource reservation and model coupling topology, the third mode may result in a reduction of resource consumption.
Collapse
|
38
|
A framework for multi-scale modelling. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2014; 372:rsta.2013.0378. [PMID: 24982249 PMCID: PMC4084523 DOI: 10.1098/rsta.2013.0378] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We review a methodology to design, implement and execute multi-scale and multi-science numerical simulations. We identify important ingredients of multi-scale modelling and give a precise definition of them. Our framework assumes that a multi-scale model can be formulated in terms of a collection of coupled single-scale submodels. With concepts such as the scale separation map, the generic submodel execution loop (SEL) and the coupling templates, one can define a multi-scale modelling language which is a bridge between the application design and the computer implementation. Our approach has been successfully applied to an increasing number of applications from different fields of science and technology.
Collapse
|
39
|
Endothelial repair process and its relevance to longitudinal neointimal tissue patterns: comparing histology with in silico modelling. J R Soc Interface 2014; 11:20140022. [PMID: 24621816 DOI: 10.1098/rsif.2014.0022] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Re-establishing a functional endothelium following endovascular treatment is an important factor in arresting neointimal proliferation. In this study, both histology (in vivo) and computational simulations (in silico) are used to evaluate neointimal growth patterns within coronary arteries along the axial direction of the stent. Comparison of the growth configurations in vivo and in silico was undertaken to identify candidate mechanisms for endothelial repair. Stent, lumen and neointimal areas were measured from histological sections obtained from eight right coronary stented porcine arteries. Two re-endothelialization scenarios (endothelial cell (EC) random seeding and EC growth from proximal and distal ends) were implemented in silico to evaluate their influence on the morphology of the simulated lesions. Subject to the assumptions made in the current simulations, comparison between in vivo and in silico results suggests that endothelial growth does not occur from the proximal and distal ends alone, but is more consistent with the assumption of a random seeding process. This may occur either from the patches of endothelium which survive following stent implantation or from attachment of circulating endothelial progenitor cells.
Collapse
|
40
|
Where do the platelets go? A simulation study of fully resolved blood flow through aneurysmal vessels. Interface Focus 2014; 3:20120089. [PMID: 24427532 DOI: 10.1098/rsfs.2012.0089] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Despite the importance of platelets in the formation of a thrombus, their transport in complex flows has not yet been studied in detail. In this paper we simulated red blood cells and platelets to explore their transport behaviour in aneurysmal geometries. We considered two aneurysms with different aspect ratios (AR = 1.0, 2.0) in the presence of fast and slow blood flows (Re = 10, 100), and examined the distributions of the cells. Low velocities in the parent vessel resulted in a large stagnation zone inside the cavity, leaving the initial distribution almost unchanged. In fast flows, an influx of platelets into the aneurysm was observed, leading to an elevated concentration. The connection of the platelet-rich cell-free layer (CFL) with the outer regions of the recirculation zones leads to their increased platelet concentration. These platelet-enhanced recirculation zones produced a diverse distribution of cells inside the aneurysm, for the different aspect ratios. A thin red blood CFL that was occupied by platelets was observed on the top of the wide-necked aneurysm, whereas a high-haematocrit region very close to the vessel wall was present in the narrow-necked case. The simulations revealed that non-trivial distributions of red blood cells and platelets are possible inside aneurysmal geometries, giving rise to several hypotheses on the formation of a thrombus, as well as to the wall weakening and the possible rupture of an aneurysm.
Collapse
|
41
|
Flexible composition and execution of high performance, high fidelity multiscale biomedical simulations. Interface Focus 2014; 3:20120087. [PMID: 24427530 DOI: 10.1098/rsfs.2012.0087] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Multiscale simulations are essential in the biomedical domain to accurately model human physiology. We present a modular approach for designing, constructing and executing multiscale simulations on a wide range of resources, from laptops to petascale supercomputers, including combinations of these. Our work features two multiscale applications, in-stent restenosis and cerebrovascular bloodflow, which combine multiple existing single-scale applications to create a multiscale simulation. These applications can be efficiently coupled, deployed and executed on computers up to the largest (peta) scale, incurring a coupling overhead of 1-10% of the total execution time.
Collapse
|
42
|
Modelling the effect of a functional endothelium on the development of in-stent restenosis. PLoS One 2013; 8:e66138. [PMID: 23785479 PMCID: PMC3681932 DOI: 10.1371/journal.pone.0066138] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Accepted: 05/01/2013] [Indexed: 11/19/2022] Open
Abstract
Treatment of stenosed coronary arteries by balloon angioplasty and stenting results in arterial injury including severe damage to the endothelium at the site of treatment and initiates a complex cascade of inflammatory processes that may lead to the development of in-stent restenosis (ISR). Many clinical and biological factors involved in the progression of restenotic lesions have been studied in detail over the past few years but the mystery behind the pathophysiological mechanisms of this disease is still unresolved. In the present work, the effects of re-endothelialization and nitric oxide release on neointimal growth are investigated in-silico using a two dimensional multi-scale model of ISR. The effect of stent deployment depths on the development of ISR is studied as a function of time after stenting. Two dimensional domains were prepared by deploying bare metal stent struts at three different deployment depths into the tissue. Shear stress distribution on endothelial cells, obtained by blood flow simulations, was translated into nitric oxide production that keeps the smooth muscle cells in quiescent state. The cellular growth trends were plotted as a function of time and the data indicate a positive correlation between the neointimal growths and strut deployment depths in the presence of a functional endothelium, in qualitative agreement with in-vivo data. Additionally, no ISR is observed if a functional endothelium appears much earlier.
Collapse
|
43
|
|
44
|
A Distributed Multiscale Computation of a Tightly Coupled Model Using the Multiscale Modeling Language. ACTA ACUST UNITED AC 2012. [DOI: 10.1016/j.procs.2012.04.064] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
45
|
Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design. Interface Focus 2011; 1:365-73. [PMID: 22670206 DOI: 10.1098/rsfs.2010.0024] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Accepted: 03/03/2011] [Indexed: 12/11/2022] Open
Abstract
Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interventional therapy. The influence of stent design parameters such as strut thickness, shape and the depth of strut deployment within the vessel wall on the severity of restenosis has already been highlighted but the detail of this influence is unclear. These factors impact on local haemodynamics and vessel structure and affect the rate of neointima formation. This paper presents the first results of a multi-scale model of ISR. The development of the simulated restenosis as a function of stent deployment depth is compared with an in vivo porcine dataset. Moreover, the influence of strut size and shape is investigated, and the effect of a drug released at the site of injury, by means of a drug-eluting stent, is also examined. A strong correlation between strut thickness and the rate of smooth muscle cell proliferation has been observed. Simulation results also suggest that the growth of the restenotic lesion is strongly dependent on the stent strut cross-sectional profile.
Collapse
|
46
|
A Framework for Multiscale and Multiscience Modeling and Numerical Simulations. LECTURE NOTES IN COMPUTER SCIENCE 2011. [DOI: 10.1007/978-3-642-21341-0_2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
47
|
Abstract
Microparticles and exosomes are cell-derived microvesicles present in body fluids that play a role in coagulation, inflammation, cellular homeostasis and survival, intercellular communication, and transport. Despite increasing scientific and clinical interest, no standard procedures are available for the isolation, detection and characterization of microparticles and exosomes, because their size is below the reach of conventional detection methods. Our objective is to give an overview of currently available and potentially applicable methods for optical and non-optical determination of the size, concentration, morphology, biochemical composition and cellular origin of microparticles and exosomes. The working principle of all methods is briefly discussed, as well as their applications and limitations based on the underlying physical parameters of the technique. For most methods, the expected size distribution for a given microvesicle population is determined. The explanations of the physical background and the outcomes of our calculations provide insights into the capabilities of each method and make a comparison possible between the discussed methods. In conclusion, several (combinations of) methods can detect clinically relevant properties of microparticles and exosomes. These methods should be further explored and validated by comparing measurement results so that accurate, reliable and fast solutions come within reach.
Collapse
|
48
|
Application of the discrete dipole approximation to very large refractive indices: Filtered coupled dipoles revived. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2010; 82:036703. [PMID: 21230209 DOI: 10.1103/physreve.82.036703] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2010] [Indexed: 05/30/2023]
Abstract
We compared three formulations of the discrete dipole approximation (DDA) for simulation of light scattering by particles with refractive indices m=10+10i , 0.1+i , and 1.6+0.01i . These formulations include the filtered coupled dipoles (FCD), the lattice dispersion relation (LDR) and the radiative reaction correction. We compared the number of iterations required for the convergence of the iterative solver (proportional to simulation time) and the accuracy of final results. We showed that the LDR performance for m=10+10i is especially bad, while the FCD is a good option for all cases studied. Moreover, we analyzed the detailed structure of DDA errors and the spectrum of the DDA interaction matrix to understand the performance of the FCD. In particular, this spectrum, obtained with the FCD for particles smaller than the wavelength, falls into the bounds, physically implied for the spectrum of the infinite-dimensional integral scattering operator, contrary to two other DDA formulations. Finally, such extreme refractive indices can now be routinely simulated using modern desktop computers using the publicly available ADDA code, which includes an efficient implementation of the FCD.
Collapse
|
49
|
Quantification of the fraction poorly deformable red blood cells using ektacytometry. OPTICS EXPRESS 2010; 18:14173-82. [PMID: 20588551 DOI: 10.1364/oe.18.014173] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We describe a method to obtain the fraction of poorly deformable red blood cells in a blood sample from the intensity pattern in an ektacytometer. In an ektacytometer red blood cells are transformed into ellipsoids by a shear flow between two transparent cylinders. The intensity pattern, due to a laser beam that is sent through the suspension, is projected on a screen. When measuring a healthy red blood cell population iso-intensity curves are ellipses with an axial ratio equal to that of the average red blood cell. In contrast poorly deformable cells result in circular iso-intensity curves. In this study we show that for mixtures of deformable and poorly deformable red blood cells, iso-intensity curves in the composite intensity pattern are neither elliptical nor circular but obtain cross-like shapes. We propose a method to obtain the fraction of poorly deformable red blood cells from those intensity patterns. Experiments with mixtures of poorly deformable and deformable red blood cells validate the method and demonstrate its accuracy. In a clinical setting our approach is potentially of great value for the detection of the fraction of sickle cells in blood samples of patients with sickle cell disease or to find a measure for the parasitemia in patients infected with malaria.
Collapse
|
50
|
Complex Automata: Multi-scale Modeling with Coupled Cellular Automata. UNDERSTANDING COMPLEX SYSTEMS 2010. [DOI: 10.1007/978-3-642-12203-3_3] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|