1
|
Randomized comparison of TAVI valves: The Compare-TAVI trial. Am Heart J 2024:S0002-8703(24)00118-2. [PMID: 38729550 DOI: 10.1016/j.ahj.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 05/01/2024] [Accepted: 05/03/2024] [Indexed: 05/12/2024]
Abstract
INTRODUCTION Based on technical advancements and clinical evidence, transcatheter aortic valve implantation (TAVI) has been widely adopted. New generation TAVI valve platforms are continually being developed. Ideally, new valves should be superior or at least non-inferior regarding efficacy and safety, when compared to best-in-practice contemporary TAVI valves. METHODS AND ANALYSIS The Compare-TAVI trial (ClinicalTrials.gov NCT04443023) was launched in 2020, to perform a 1:1 randomized comparison of new versus contemporary TAVI valves, preferably in all comers. Consecutive cohorts will be launched with sample sizes depending on the choice of interim analyses, expected event rates, and chosen superiority or non-inferiority margins. Enrollment has just been finalized in cohort B, comparing the Sapien 3/ Sapien 3 Ultra Transcatheter Heart Valve (THV) series (Edwards Lifesciences, Irvine, California, USA) and the Myval/Myval Octacor THV series (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) balloon expandable valves. This non-inferiority study was aimed to include 1062 patients. The 1-year composite safety and efficacy endpoint comprises death, stroke, moderate-severe aortic regurgitation, and moderate-severe valve deterioration. Patients will be followed until withdrawal of consent, death, or completion of 10-year follow-up, whichever comes first. Secondary endpoints will be monitored at 30 days, 1, 3, 5, and 10 years. SUMMARY The Compare-TAVI organization will launch consecutive cohorts wherein patients scheduled for TAVI are randomized to one of two valves. The aim is to ensure that the short- and long-term performance and safety of new valves being introduced is benchmarked against what achieved bybest-in-practice contemporary valves.
Collapse
|
2
|
Effects of litter amount and seed sowing position on seedling emergence and growth of hemiparasitic Rhinanthus species under drought stress. PLANT BIOLOGY (STUTTGART, GERMANY) 2024; 26:437-445. [PMID: 38430522 DOI: 10.1111/plb.13633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 01/24/2024] [Indexed: 03/04/2024]
Abstract
Roadside vegetation in Central Europe is mostly species-poor and dominated by a few grass species. Hemiparasitic plant species, including Rhinanthus spp., might effectively restrict grass growth, thereby making space for light-dependent herb species. Despite the significance of abiotic site conditions for plant establishment in general, their effects on Rhinanthus establishment are less well known. We investigated combined effects of water availability, litter amount and seed position within litter on Rhinanthus seedling emergence and growth. Two parallel greenhouse experiments were conducted with R. angustifolius and R. minor. In these, we tested the impact of 200 or 400 g litter·m-2 with seeds sown beneath or on top of a litter layer under constantly humid or intermittently dry conditions on seedling emergence and biomass production of Rhinanthus. Presence of litter positively affected Rhinanthus seedling emergence when sown beneath the litter layer and reduced negative effects of water deficiency. Sowing beneath a litter layer increased seedling emergence by 157%, with similar effects at 200 and 400 g litter·m-2. Water level did not affect biomass production. Compared to R. minor, R. angustifolius had higher mean biomass, and its seedlings emerged earlier and in higher numbers. Our results indicate that Rhinanthus spp. react similarly to litter as non-hemiparasitic plant species from temperate grasslands. Litter presence positively influenced Rhinanthus seedling emergence and growth under intermittently dry conditions. Its hemiparasitic characteristics might reduce drought impacts on biomass production. To ensure seed contact with the soil surface, seeds should be sown when no litter is present, or mulching should occur post-sowing.
Collapse
|
3
|
Transcatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial. Eur Heart J 2024; 45:1116-1124. [PMID: 38321820 PMCID: PMC10984572 DOI: 10.1093/eurheartj/ehae043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/26/2023] [Accepted: 01/16/2024] [Indexed: 02/08/2024] Open
Abstract
BACKGROUND AND AIMS Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years. METHODS The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30 mmHg or more and an increase in transprosthetic gradient of 20 mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD. RESULTS Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4). CONCLUSIONS In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.
Collapse
|
4
|
Pulmonary Valve Replacement in Tetralogy of Fallot: Procedural Volume and Durability of Bioprosthetic Pulmonary Valves. JACC Cardiovasc Interv 2024; 17:217-227. [PMID: 38127022 DOI: 10.1016/j.jcin.2023.10.070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/26/2023] [Accepted: 10/10/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Robust data on changes in pulmonary valve replacement (PVR) procedural volume and predictors of bioprosthetic pulmonary valve (BPV) durability in patients with tetralogy of Fallot (TOF) are scarce. OBJECTIVES This study sought to assess temporal trends in PVR procedural volume and BPV durability in a nationwide, retrospective TOF cohort. METHODS Data were obtained from patient records. Robust linear regression was used to assess temporal trends in PVR procedural volume. Piecewise exponential additive mixed models were used to estimate BPV durability, defined as the time from implantation to redo PVR with death as a competing risk, and to assess risk factors for reduced durability. RESULTS In total, 546 PVR were performed in 384 patients from 1976 to 2021. The annual number of PVR increased from 0.4 to 6.0 per million population (P < 0.001). In the last decade, the transcatheter PVR volume increased by 20% annually (P < 0.001), whereas the surgical PVR volume did not change significantly. The median BPV durability was 17 years (Q1: 10-Q3: 10 years-not applicable). There was no significant difference in the durability of different BPV after adjustment for confounders. Age at PVR (HR: 0.78 per 10 years from <1 year; 95% CI: 0.63-0.96; P = 0.02) and true inner valve diameter (9-17 mm vs 18-22 mm HR: 0.40; 95% CI: 0.22-0.73; P = 0.003 and 18-22 mm vs 23-30 mm HR: 0.59; 95% CI: 0.25-1.39; P = 0.23) were associated with reduced BPV durability in multivariate models. CONCLUSIONS The PVR procedural volume has increased over time, with a greater increment in transcatheter than surgical PVR during the last decade. Younger patient age at PVR and a smaller true inner valve diameter predicted reduced BPV durability.
Collapse
|
5
|
Temporal Trends in Patient Characteristics and Outcomes of Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement: A Nationwide Study. Am J Cardiol 2024; 211:299-306. [PMID: 37984636 DOI: 10.1016/j.amjcard.2023.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 11/05/2023] [Accepted: 11/11/2023] [Indexed: 11/22/2023]
Abstract
With increased use of transcatheter aortic valve implantation (TAVI) in treatment of aortic stenosis, it is important to evaluate real life data trends in outcomes. This nationwide register-based study aimed to present an outlook on temporal trends in characteristics and outcomes, including mortality. First-time consecutive Danish patients who underwent TAVI from 2010 to 2019 were included in this study. The chi-square and Kruskal-Wallis tests were performed to assess the differences in the characteristics over time and Cochrane-Armitage trend tests were used to examine changes in complications and mortality. Between 2010 and 2019, 4,847 patients (54.6% men, median age 82 [quartile 1 to quartile 3: 77 to 85] years) underwent first-time TAVI. A statistically significant decrease over time was observed for preprocedural hypertension, ischemic heart disease, and heart failure, whereas preexisting chronic obstructive lung disease and preprocedural pacemaker remained stable. We observed a significant decrease in 30- and 90-day postoperative preprocedural pacemaker implantation from 2011 to 2017, with 15.1% and 15.9% in 2011 and 8.6% and 8.9% in 2017, respectively. The incidence of for 30- and 90-day heart failure significantly decreased from 19.3% and 20.3% to 8.5% and 9.1%, respectively. We observed significant changes for 30-day atrial fibrillation, whereas the changes over time for 90-day atrial fibrillation and 30- and 90-day stroke/transient ischemic attack remained insignificant. The all-cause mortality within 30- and 90 days significantly decreased over time from 6.7% and 9.2% in 2011 to 1.5% and 2.7% in 2019 and 2016, respectively. In conclusion, this national study provides general insight on the trends of complications and mortality of TAVI, demonstrating significant reductions over time.
Collapse
|
6
|
Impact of mandatory preoperative dental screening on post-procedural risk of infective endocarditis in patients undergoing transcatheter aortic valve implantation: a nationwide retrospective observational study. THE LANCET REGIONAL HEALTH. EUROPE 2024; 36:100789. [PMID: 38188272 PMCID: PMC10769890 DOI: 10.1016/j.lanepe.2023.100789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/02/2023] [Accepted: 11/03/2023] [Indexed: 01/09/2024]
Abstract
Background Guidelines recommend preoperative dental screening (PDS) prior to cardiac valve surgery, to reduce the incidence of prosthetic valve infective endocarditis (IE). However, limited data support these recommendations, particular in patients undergoing transcatheter aortic valve implantation (TAVI). We aimed to investigate the effect of mandatory PDS on risk of IE in patients undergoing TAVI. Methods In this observational study, a total of 1133 patients undergoing TAVI in Western-Denmark from 2020 to 2022 were included. Patients were categorized based on two implemented PDS practices: mandatory PDS (MPDS group), and no referral for PDS (NPDS group). Outcome data were retrieved from Danish registries and confirmed using medical records. The primary outcome was incidence of IE. Secondary outcomes were all-cause mortality and composite outcome of all-cause mortality and IE. Findings Of 568 patients in the MPDS group 126 (22.2%) underwent subsequent oral dental surgery, compared to 8 (1.4%) among 565 patients in the NPDS group. During a median follow-up of 1.9 years (interquartile range 1.4-2.5 years), 31 (2.7%) developed IE. The yearly incidence IE rate was 1.4% (0.8-2.3) and 1.5% (0.8-2.4) in MPDS and NPDS, respectively, p = 0.86. All-cause mortality rates were similar between groups (estimated 2-year overall mortality of 6.7% (4.8-9.2) vs. 4.7% (3.2-6.9), MPDS and NPDS, respectively, p = 0.15). Consistent findings were found in 712 propensity score-matched patients. Interpretation Mandatory PDS did not demonstrate reduced risk of IE or all-cause mortality compared to targeted PDS in patients undergoing TAVI. Funding The funder had no role in the study design, data management, or writing.
Collapse
|
7
|
Quantitative aortography for assessment of aortic regurgitation in the era of percutaneous aortic valve replacement. Front Cardiovasc Med 2023; 10:1161779. [PMID: 37529710 PMCID: PMC10389707 DOI: 10.3389/fcvm.2023.1161779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 05/24/2023] [Indexed: 08/03/2023] Open
Abstract
Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.
Collapse
|
8
|
Transcatheter valve-in-valve or valve-in-ring implantation with a novel balloon-expandable device in patients with bioprosthetic left side heart valves failure: 1-year follow-up from a multicenter experience. Int J Cardiol 2023; 376:35-45. [PMID: 36657566 DOI: 10.1016/j.ijcard.2023.01.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/29/2022] [Accepted: 01/12/2023] [Indexed: 01/18/2023]
Abstract
BACKGROUND Transcatheter aortic and mitral valve-in-valve (ViV) or valve-in-ring (ViR) implantation into failed bioprosthetic heart valves (BHVs) or rings represents an appealing, less invasive, treatment option for patients at high surgical risk. Nowadays, few data have been reported on the use of balloon-expandable Myval (Meril Life Science, Vapi, India) transcatheter heart valve (THV) for the treatment of degenerated BHVs or rings. We aimed at evaluating the early and mid-term clinical outcomes of patients with left side heart bioprosthesis deterioration treated with transcatheter ViV/ViR implantation using Myval THV. METHODS 97 consecutive patients with symptomatic, severe aortic(n=33) and mitral(n=64) BHVs/ring dysfunction underwent transcatheter aortic ViV and mitral ViV/ViR implantation with Myval THV. RESULTS Technical success was achieved in 95 (98%) of the patients. Two cases of acute structural trans-catheter mitral ViV/ViR dysfunction requiring a second THV implantation were reported. At 30-day, a significant reduction in prosthetic trans-valvular pressure gradients and increase in valve areas were seen following both aortic and mitral ViV/ViR implantation. Overall survival at 15 months (IQR 8-21) was 92%. Patients undergoing mitral ViV/ViR had a relatively worse survival compared with those undergoing aortic ViV implantation (89% vs. 97% respectively; HR:2.7,CI:0.33-22.7;p=0.34). At longest follow-up available a significant improvement in NYHA functional class I and II was observed in patients with aortic and mitral ViV/ViR implantation(93.8% and 92.1%). CONCLUSIONS Despite high surgical risk, transcatheter ViV/ViR implantation for failed left side heart bioprosthesis can be performed safely using Myval THV with a high success rate and low early and mid-term mortality and morbidity.
Collapse
|
9
|
One-Year Outcomes after Myval Implantation in Patients with Bicuspid Aortic Valve Stenosis-A Multicentre Real-World Experience. J Clin Med 2023; 12:jcm12062398. [PMID: 36983397 PMCID: PMC10054138 DOI: 10.3390/jcm12062398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/08/2023] [Accepted: 03/09/2023] [Indexed: 03/30/2023] Open
Abstract
BACKGROUND Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. AIM To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. METHODS AND RESULTS We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. CONCLUSIONS TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.
Collapse
|
10
|
Temporal changes in the surgical management of patients with tetralogy of Fallot in Denmark: a nationwide cohort study. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY : OFFICIAL JOURNAL OF THE EUROPEAN ASSOCIATION FOR CARDIO-THORACIC SURGERY 2023; 63:6972777. [PMID: 36617167 DOI: 10.1093/ejcts/ezad007] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 12/02/2022] [Accepted: 01/05/2023] [Indexed: 01/09/2023]
Abstract
OBJECTIVES To assess temporal changes in the surgical management of patients with tetralogy of Fallot including the timing of interventions, surgical techniques, reinterventions and survival in a nationwide cohort. METHODS Patients with tetralogy of Fallot in Denmark were divided into 3 eras based on their year of birth: early (1977-1991), intermediate (1992-2006) and late (2007-2021). RESULTS The cohort consisted of 745 patients. Median follow-up was 21.2 years (13.7-30.5). There was a temporal trend towards less shunt palliation (-0.3% per year, 95% CI -0.05 to -0.1). Median age at intracardiac repair was 2.9 years (1.8-5.0), 0.8 years (0.5-1.3) and 0.5 years (0.4-0.7) (P < 0.001) in the early, intermediate and late era, respectively. There was a temporal trend towards less valve-sparing repair (-0.7% per year, 95% CI -0.5 to -1.0) and more repair with transannular patches (0.7% per year, 95% CI 0.5-1.0). Survival at 10 years was 79% (64-76), 90% (87-93) and 95% (92-98) (P < 0.001) and pulmonary valve replacement within the first 10 years after intracardiac repair was performed in 3% (1-6), 12% (8-16) and 21% (13-29) (P < 0.001) in the early, intermediate and late era, respectively. CONCLUSIONS There was a temporal trend towards less shunt palliation and intracardiac repair at a younger age with more use of transannular patches. While survival throughout childhood and adolescence has improved, more patients undergo pulmonary valve replacement during the first 10 years after intracardiac repair.
Collapse
|
11
|
Case report: Transcatheter aortic valve replacement in a large bicuspid anatomy using the XL-Myval 32 mm. Front Cardiovasc Med 2022; 9:1045280. [PMID: 36505358 PMCID: PMC9727381 DOI: 10.3389/fcvm.2022.1045280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 10/27/2022] [Indexed: 11/25/2022] Open
Abstract
Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone. Most commercial transcatheter heart valves (THV) have upper dimension limits of the annulus and area in which the device can be implanted safely without significant oversizing. Myval-XL THVs (Meril Life Sciences Pvt. Ltd., India) are balloon-expandable valves (BEV) that have been developed with two new sizes, 30.5 and 32 mm, aiming to treat patients with large annulus dimensions and that exceed the upper limit of an ordinary device's sizing matrix. This case series report describes TAVR using the XL-Myval 32 mm THV in three European patients with symptomatic severe bicuspid aortic stenosis with significant calcifications and large annular dimensions exceeding the limits of the other THVs.
Collapse
|
12
|
TCT-487 Mid-Term Outcome of Transcatheter Aortic Valve Replacement Using Myval in Severe Bicuspid Aortic Stenosis. J Am Coll Cardiol 2022. [DOI: 10.1016/j.jacc.2022.08.573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
13
|
Safety and Efficacy of Myval Implantation in Patients with Severe Bicuspid Aortic Valve Stenosis-A Multicenter Real-World Experience. J Clin Med 2022; 11:jcm11020443. [PMID: 35054137 PMCID: PMC8779274 DOI: 10.3390/jcm11020443] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/11/2022] [Accepted: 01/13/2022] [Indexed: 11/16/2022] Open
Abstract
Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.
Collapse
|
14
|
Eight-year outcomes for patients with aortic valve stenosis at low surgical risk randomized to transcatheter vs. surgical aortic valve replacement. Eur Heart J 2021; 42:2912-2919. [PMID: 34179981 PMCID: PMC8347457 DOI: 10.1093/eurheartj/ehab375] [Citation(s) in RCA: 129] [Impact Index Per Article: 43.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/14/2021] [Accepted: 06/04/2021] [Indexed: 12/30/2022] Open
Abstract
Aims The aims of the study were to compare clinical outcomes and valve durability after 8 years of follow-up in patients with symptomatic severe aortic valve stenosis at low surgical risk treated with either transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR). Methods and results In the NOTION trial, patients with symptomatic severe aortic valve stenosis were randomized to TAVI or SAVR. Clinical status, echocardiography, structural valve deterioration, and failure were assessed using standardized definitions. In total, 280 patients were randomized to TAVI (n = 145) or SAVR (n = 135). Baseline characteristics were similar, including mean age of 79.1 ± 4.8 years and a mean STS score of 3.0 ± 1.7%. At 8-year follow-up, the estimated risk of the composite outcome of all-cause mortality, stroke, or myocardial infarction was 54.5% after TAVI and 54.8% after SAVR (P = 0.94). The estimated risks for all-cause mortality (51.8% vs. 52.6%; P = 0.90), stroke (8.3% vs. 9.1%; P = 0.90), or myocardial infarction (6.2% vs. 3.8%; P = 0.33) were similar after TAVI and SAVR. The risk of structural valve deterioration was lower after TAVI than after SAVR (13.9% vs. 28.3%; P = 0.0017), whereas the risk of bioprosthetic valve failure was similar (8.7% vs. 10.5%; P = 0.61). Conclusions In patients with severe aortic valve stenosis at low surgical risk randomized to TAVI or SAVR, there were no significant differences in the risk for all-cause mortality, stroke, or myocardial infarction, as well as the risk of bioprosthetic valve failure after 8 years of follow-up. Clinical trial registration URL: http://www.ClinicalTrials.gov. Unique identifier: NCT01057173.
Collapse
|
15
|
Permanent Pacemaker Implantation Following Valve-in-Valve Transcatheter Aortic Valve Replacement: VIVID Registry. J Am Coll Cardiol 2021; 77:2263-2273. [PMID: 33958122 DOI: 10.1016/j.jacc.2021.03.228] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 03/10/2021] [Accepted: 03/15/2021] [Indexed: 12/21/2022]
Abstract
BACKGROUND Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.
Collapse
|
16
|
Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves. Eur Heart J 2020; 41:2731-2742. [DOI: 10.1093/eurheartj/ehaa544] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 05/09/2020] [Accepted: 06/22/2020] [Indexed: 11/13/2022] Open
Abstract
Abstract
Aims
Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV.
Methods and results
A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2–12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02–1.13)], age [HR 1.21 (95% CI 1.01–1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11–1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis–patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31–14.39)], device malposition [SHR 3.75 (95% CI 1.36–10.35)], EBEV [SHR 3.34 (95% CI 1.26–8.85)], and age [SHR 0.59 (95% CI 0.44–0.78)].
Conclusions
The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
Collapse
|
17
|
Early and late risk of ischemic stroke after TAVR as compared to a nationwide background population. Clin Res Cardiol 2019; 109:791-801. [DOI: 10.1007/s00392-019-01565-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 10/18/2019] [Indexed: 11/29/2022]
|
18
|
Five-Year Clinical and Echocardiographic Outcomes From the NOTION Randomized Clinical Trial in Patients at Lower Surgical Risk. Circulation 2019; 139:2714-2723. [PMID: 30704298 DOI: 10.1161/circulationaha.118.036606] [Citation(s) in RCA: 203] [Impact Index Per Article: 40.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND The NOTION trial (Nordic Aortic Valve Intervention) was designed to compare transcatheter aortic valve replacement (TAVR) with surgical aortic valve replacement (SAVR) in patients ≥70 years old with isolated severe aortic valve stenosis. Clinical and echocardiographic outcomes are presented after 5 years. METHODS Patients were enrolled at 3 Nordic centers and randomized 1:1 to TAVR using the self-expanding CoreValve prosthesis (n=145) or SAVR using any stented bioprostheses (n=135). The primary composite outcome was the rate of all-cause mortality, stroke, or myocardial infarction at 1 year defined according to Valve Academic Research Consortium-2 criteria. RESULTS Baseline characteristics were similar. The mean age was 79.1±4.8 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 3.0%±1.7%. After 5 years, there were no differences between TAVR and SAVR in the composite outcome (Kaplan-Meier estimates 38.0% versus 36.3%, log-rank test P=0.86) or any of its components. TAVR patients had larger prosthetic valve area (1.7 cm2 versus 1.2 cm2, P<0.001) with a lower mean transprosthetic gradient (8.2 mm Hg versus 13.7 mm Hg, P<0.001), both unchanged over time. More TAVR patients had moderate/severe total aortic regurgitation (8.2% versus 0.0%, P<0.001) and a new pacemaker (43.7% versus 8.7%, P<0.001). Four patients had prosthetic reintervention and no difference was found for functional outcomes. CONCLUSIONS These are currently the longest follow-up data comparing TAVR and SAVR in lower risk patients, demonstrating no statistical difference for major clinical outcomes 5 years after TAVR with a self-expanding prosthesis compared to SAVR. Higher rates of prosthetic regurgitation and pacemaker implantation were seen after TAVR. CLINICAL TRIAL REGISTRATION URL: https://clinicaltrials.gov. Unique identifier: NCT01057173.
Collapse
|
19
|
Durability of Transcatheter and Surgical Bioprosthetic Aortic Valves in Patients at Lower Surgical Risk. J Am Coll Cardiol 2019; 73:546-553. [DOI: 10.1016/j.jacc.2018.10.083] [Citation(s) in RCA: 212] [Impact Index Per Article: 42.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/26/2018] [Accepted: 10/30/2018] [Indexed: 12/17/2022]
|
20
|
[Transcatheter aortic valve implantation in Denmark]. Ugeskr Laeger 2018; 180:V05180340. [PMID: 30274590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
During the latest decade, transcatheter aortic valve implantation (TAVI) has evolved from being indicated only in patients with severe aortic stenosis and prohibitive or high surgical risk, to be an alternative to surgical aortic valve replacement in patients with intermediate surgical risk. Improvements of the peri-procedural management have resulted in marked reduction of complications and an increasing number of patients treated with TAVI every year in Denmark. By a minimalist approach, TAVI can be performed in local anesthaesia, with same day mobilisation and discharge within few days, without affecting the safety.
Collapse
|
21
|
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve-in-Valve International Data (VIVID). Catheter Cardiovasc Interv 2018; 92:1163-1170. [PMID: 30079597 DOI: 10.1002/ccd.27714] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 04/28/2018] [Accepted: 06/10/2018] [Indexed: 11/12/2022]
Abstract
BACKGROUND Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Collapse
|
22
|
Pulmonary arteriovenous malformations: a radiological and clinical investigation of 136 patients with long-term follow-up. Clin Radiol 2018; 73:951-957. [PMID: 30086858 DOI: 10.1016/j.crad.2018.07.096] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 07/05/2018] [Indexed: 11/19/2022]
Abstract
AIM To assess the clinical outcome of patients with and without hereditary haemorrhagic telangiectasia (HHT) after embolisation of pulmonary arteriovenous malformations (PAVM) from a single national centre. MATERIALS AND METHODS The present register-based observational study including all patients with PAVM treated with embolisation at a reference centre for HHT and PAVM was undertaken over a 20-year period. Demographic data, HHT genotyping, clinical presentation, and outcome were registered. Patients with HHT were compared to the patients without HHT. Clinical examination, contrast-enhanced echocardiography, and computed tomography (CT) were used to assess the clinical outcome at follow-up. RESULTS One hundred and thirty-six patients with 339 PAVM underwent embolisation during the study period: 22 did not have HHT; 62% had HHT1, 10% had HHT2, 4% had JP-HHT, 8% had clinical HHT without identified genetic mutations. Solitary PAVM were more common among patients without HHT than with HHT. Mean follow-up after the first embolisation was 58 months. Mean age at first embolisation was 46.5 years, and at last follow-up 51.8 years. The clinical success without shunt at follow-up was 87%. The 30-day mortality related to the embolisation was 0%. Twenty patients died during follow-up (mean age 69 years). Most patients could be treated during one session, but many will need a long follow-up with repeated clinical examinations and embolisation. CONCLUSION The majority of patients referred for embolisation of PAVM had HHT. Multiple PAVM is associated with HHT. Patients with PAVM should be screened for HHT and patients with HHT for PAVM. Embolisation is a safe procedure with high clinical success.
Collapse
|
23
|
Short- and Long-Term Mortality and Stroke Risk After Transcatheter Aortic Valve Implantation. Am J Cardiol 2018; 121:78-85. [PMID: 29103605 DOI: 10.1016/j.amjcard.2017.09.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 09/18/2017] [Accepted: 09/19/2017] [Indexed: 01/05/2023]
Abstract
No published studies have compared the outcome after transcatheter aortic valve implantation (TAVI) with the outcome in the general population. Thus, it is unknown whether TAVI restores normal life expectancy and stroke risk. Furthermore, despite the increasing use of TAVI, only little is known about the temporal trends for TAVI regarding patient characteristics and outcomes. We identified all Danish patients treated with TAVI from 2006 to 2014 (n = 1,631) and 9,737 general population controls matched by gender, age, and co-morbidity. The primary end point was a composite end point of all-cause mortality and stroke. During the first 90 days, the risk of the combined end point, the stroke risk, and mortality were significantly higher among TAVI patients compared with controls (9.4%, 7.5%, and 2.5%, respectively, in TAVI patients compared with 2.0%, 1.6%, and 0.5% in controls). After 90 days, there were no differences (adjusted mortality rate ratio, stroke rate ratio, and mortality or stroke rate ratio 0.92 [0.79 to 1.06], 1.32 [0.98 to 1.78], and 1.00 [0.90 to 1.10], respectively). During the study period, there were small changes in the characteristics of patients treated with TAVI; however, more patients were treated by transfemoral access; fewer needed blood transfusions, hospital stays were shorter, and the overall mortality rate decreased. In conclusion, 90 days after TAVI, the stroke risk and mortality of the TAVI patients were comparable with the stroke risk and mortality of the general population. Over time, the patient risk profiles have remained largely unchanged; however, outcomes have improved substantially, including lower short- and long-term mortality.
Collapse
|
24
|
|
25
|
Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial. Circ Cardiovasc Interv 2017; 9:CIRCINTERVENTIONS.115.003665. [PMID: 27296202 DOI: 10.1161/circinterventions.115.003665] [Citation(s) in RCA: 136] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 04/27/2016] [Indexed: 11/16/2022]
Abstract
BACKGROUND The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), including a lower-risk patient population than previous trials. This article reports 2-year clinical and echocardiographic outcomes from the NOTION trial. METHODS AND RESULTS Two-hundred eighty patients from 3 centers in Denmark and Sweden were randomized to either TAVR (n=145) or SAVR (n=135) with follow-up planned for 5 years. There was no difference in all-cause mortality at 2 years between TAVR and SAVR (8.0% versus 9.8%, respectively; P=0.54) or cardiovascular mortality (6.5% versus 9.1%; P=0.40). The composite outcome of all-cause mortality, stroke, or myocardial infarction was also similar (15.8% versus 18.8%, P=0.43). Forward-flow hemodynamics were improved following both procedures, with effective orifice area significantly more improved after TAVR than SAVR (effective orifice area, 1.7 versus 1.4 cm(2) at 3 months). Mean valve gradients were similar after TAVR and SAVR. When patients were categorized according to Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (<4% versus ≥4%), there was no statistically significant difference for TAVR and SAVR groups in the composite outcome for low-risk (14.7%, 95% confidence interval, 8.3-21.2 versus 16.8%; 95% confidence interval, 9.7-23.8; P=0.58) or intermediate-risk patients (21.1% versus 27.1%; P=0.59). CONCLUSIONS Two-year results from the NOTION trial demonstrate the continuing safety and effectiveness of TAVR in lower-risk patients. Longer-term data are needed to verify the durability of this procedure in this patient population. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173.
Collapse
|
26
|
Abstract
Interventional cardiology in Denmark has been carried out since the mid 1980s. Interventional cardiology is only performed at a few high-volume centres. Healthcare coverage is universal and is essentially free of charge. Hospitals are mostly publicly owned and financed by fixed budgets and, in part, an activity-based funding system. Approximately 30,000 coronary angiographies (CAG), 10,000 percutaneous coronary interventions (PCIs) of which approximately 25% are primary PCIs, and 500 transcatheter aortic valve implantations (TAVIs) are carried out each year. The numbers of CAG and PCI have reached a plateau in recent years, whereas structural heart interventions, in particular TAVI, are increasing. Around 90% of all patients treated with PCI have a stent implanted, with more than 95% of these being drug-eluting stents. There is a low but increasing use of bioabsorbable scaffolds and drug-eluting balloons.
Collapse
|
27
|
TCT-652 Incidence, Predictors and Clinical Outcomes of Device Malposition Following Transcatheter Aortic Valve Implantation for Degenerative Bioprosthetic Surgical Valves: Insights from the VIVID Registry. J Am Coll Cardiol 2016. [DOI: 10.1016/j.jacc.2016.09.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
28
|
|
29
|
Transcatheter Replacement of Failed Bioprosthetic Valves. Circ Cardiovasc Interv 2016; 9:CIRCINTERVENTIONS.115.003651. [DOI: 10.1161/circinterventions.115.003651] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Accepted: 04/29/2016] [Indexed: 11/16/2022]
Abstract
Background—
Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets for implantation that would improve hemodynamics after ViV.
Methods and Results—
Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated postprocedural gradients (mean ≥20 mm Hg). Optimal implantation depths were defined by receiver operating characteristic curve. A total of 292 consecutive patients (age, 78.9±8.7 years; 60.3% male; 157 CoreValve Evolut and 135 Sapien XT) were evaluated. High implantation was associated with significantly lower rates of elevated gradients in comparison with low implantation (CoreValve Evolut, 15% versus 34.2%;
P
=0.03 and Sapien XT, 18.5% versus 43.5%;
P
=0.03, respectively). Optimal implantation depths were defined: CoreValve Evolut, 0 to 5 mm; Sapien XT, 0 to 2 mm (0–10% frame height); sensitivities, 91.3% and 88.5%, respectively. The strongest independent correlate for elevated gradients after ViV was device position (high: odds ratio, 0.22; confidence interval, 0.1–0.52;
P
=0.001), in addition to type of device used (CoreValve Evolut: odds ratio, 0.5; confidence interval, 0.28–0.88;
P
=0.02) and surgical valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51–6.45;
P
=0.002).
Conclusions—
High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self- and balloon-expandable transcatheter valves. These clinical evaluations support specific implantation targets to optimize hemodynamics after ViV.
Collapse
|
30
|
No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis from the NOTION trial. Eur J Cardiothorac Surg 2016; 50:721-728. [PMID: 27005980 DOI: 10.1093/ejcts/ezw095] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 02/15/2016] [Accepted: 02/22/2016] [Indexed: 02/06/2023] Open
Abstract
OBJECTIVES Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) for severe aortic valve stenosis (AVS) is common, but less common after transcatheter aortic valve replacement (TAVR) in patients considered at high risk for death after surgery. The objectives of this study were to determine incidence and clinical effect of PPM after SAVR and TAVR in a primarily low-risk patient group. METHODS Patients 70 years or older with severe isolated AVS, regardless of predicted operative mortality risk, were consecutively randomized 1:1 to TAVR using a self-expandable bioprosthesis (n = 145) or SAVR (n = 135). Post-procedure PPM was graded after 3 months as follows: Not present-mild, if indexed effective orifice area (iEOA) >0.85 cm2/m2, moderate, if 0.65 cm2/m2 < iEOA ≤ 0.85 cm2/m2 and severe, if iEOA ≤0.65 cm2/m2. Outcomes were major adverse cardiac and cerebrovascular events (MACCE, e.g. composite rate of all-cause death, stroke, myocardial infarction or valve reintervention), cardiac-related hospitalizations and New York Heart Association (NYHA) functional class after 2 years. RESULTS The incidence and the severity of PPM were significantly lower after TAVR compared with SAVR (severe, moderate, none-mild 14.0, 35.5, 50.4 vs 33.9, 36.7, 29.4%; P<0.001). PPM resulted in similar higher mean valve gradients at 3 months for both groups. Baseline characteristics related to severe PPM were younger age, absence of diabetes mellitus, lower mortality-risk score for TAVR, and younger age and higher body mass index for SAVR. At 2 years, there were numerical but no statistically significant differences between both TAVR and SAVR patients with severe and no severe PPM for MACCE (0.0 vs 12.8% for TAVR; P = 0.13, and 13.5 vs 7.0% for SAVR; P = 0.27), number of cardiac-related hospitalizations (mean ± standard deviation 0.4 ± 0.6 vs 0.6 ± 0.8; P = 0.23, and 0.4 ± 0.8 vs 0.5 ± 0.9; P = 0.70) and NYHA functional class (Class I/II/III/IV: 64.7/29.4/5.9/0.0 vs 62.1/34.7/3.2/0.0%, respectively; P = 0.91, and 71.4/25.7/2.9/0.0 vs 72.9/22.9/4.3/0.0%, respectively; P = 0.92). CONCLUSIONS The incidence of PPM was lower and less severe after TAVR compared with SAVR in intermediate- and low-risk patients with severe AVS. There were no significant differences in MACCE, cardiac-related hospitalizations or NYHA class after 2 years for patients with versus those without severe PPM.
Collapse
|
31
|
Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial. J Am Coll Cardiol 2015; 65:2184-94. [PMID: 25787196 DOI: 10.1016/j.jacc.2015.03.014] [Citation(s) in RCA: 645] [Impact Index Per Article: 71.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 03/03/2015] [Accepted: 03/04/2015] [Indexed: 01/28/2023]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is an option in certain high-risk surgical patients with severe aortic valve stenosis. It is unknown whether TAVR can be safely introduced to lower-risk patients. OBJECTIVES The NOTION (Nordic Aortic Valve Intervention Trial) randomized clinical trial compared TAVR with surgical aortic valve replacement (SAVR) in an all-comers patient cohort. METHODS Patients ≥ 70 years old with severe aortic valve stenosis and no significant coronary artery disease were randomized 1:1 to TAVR using a self-expanding bioprosthesis versus SAVR. The primary outcome was the composite rate of death from any cause, stroke, or myocardial infarction (MI) at 1 year. RESULTS A total of 280 patients were randomized at 3 Nordic centers. Mean age was 79.1 years, and 81.8% were considered low-risk patients. In the intention-to-treat population, no significant difference in the primary endpoint was found (13.1% vs. 16.3%; p = 0.43 for superiority). The result did not change in the as-treated population. No difference in the rate of cardiovascular death or prosthesis reintervention was found. Compared with SAVR-treated patients, TAVR-treated patients had more conduction abnormalities requiring pacemaker implantation, larger improvement in effective orifice area, more total aortic valve regurgitation, and higher New York Heart Association functional class at 1 year. SAVR-treated patients had more major or life-threatening bleeding, cardiogenic shock, acute kidney injury (stage II or III), and new-onset or worsening atrial fibrillation at 30 days than did TAVR-treated patients. CONCLUSIONS In the NOTION trial, no significant difference between TAVR and SAVR was found for the composite rate of death from any cause, stroke, or MI after 1 year. (Nordic Aortic Valve Intervention Trial [NOTION]; NCT01057173).
Collapse
|
32
|
Impact of chronic obstructive pulmonary disease on survival and symptoms of severe aortic valve stenosis. SCAND CARDIOVASC J 2015; 49:49-55. [DOI: 10.3109/14017431.2015.1006671] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
33
|
Abstract
IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.
Collapse
|
34
|
Cerebral abscesses among Danish patients with hereditary haemorrhagic telangiectasia. Acta Neurol Scand 2014; 129:192-7. [PMID: 23962120 DOI: 10.1111/ane.12167] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/19/2013] [Indexed: 12/22/2022]
Abstract
BACKGROUND Hereditary haemorrhagic telangiectasia (HHT) is a dominantly inherited disease characterized by a wide variety of clinical manifestations, including pulmonary arteriovenous malformations (PAVMs), which due to paradoxical embolization may cause cerebral abscess. OBJECTIVE To estimate the risk of cerebral abscess among patients with HHT. METHODS All patients with HHT included in the Danish HHT data base, between January 1995 and October 2012, have been clinically evaluated for the presence of neurological symptoms and history of previous cerebral abscess. RESULTS A total of 337 patients with HHT have been included in the Danish database. Of these, 264 were screened for the presence of PAVM. In 117 patients, a PAVM was diagnosed; among these, we identified nine patients with a history of cerebral abscess. The prevalence of cerebral abscess among patients with HHT and PAVM was therefore 7.8%. The patients with a history of cerebral abscess were genetically evaluated, and seven had ENG mutations, one had an ALK1 mutation, and in one case, a mutation could not be identified. CONCLUSION Patients with untreated PAVM have a considerable risk of sustaining cerebral abscesses. A cerebral abscess may be the first symptom leading to an HHT diagnosis. Patients with unexplained cerebral abscess should be evaluated for HHT and PAVM.
Collapse
|
35
|
PO-0910: Beyond the mean apparent diffusion coefficient: multi-parametric analysis of diffusion-weighted imaging. Radiother Oncol 2014. [DOI: 10.1016/s0167-8140(15)31028-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
36
|
[Platypnoea-orthodeoxia: a rare cause of severe dyspnoea]. Ugeskr Laeger 2013; 175:V11120636. [PMID: 25353093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Platypnoea-orthodeoxia is a relatively unknown syndrome characterized by dyspnoea and arterial desaturation during the transition from a lying to an uprighth position by right to left shunting of blood without increased blood pressure in the right atrium. The condition is assumed to be underdiagnosed because of challenging diagnostics. This case describes a woman who, despite extensive investigation, remained undiagnosed for years. The diagnosis should be kept in mind when treating unexplained desaturation.
Collapse
|
37
|
A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial. EUROINTERVENTION 2013; 8:383-9. [PMID: 22581299 DOI: 10.4244/eijv8i3a58] [Citation(s) in RCA: 139] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS In a prospective randomised trial we aimed to compare transapical transcatheter aortic valve implantation (a-TAVI) with surgical aortic valve replacement (SAVR) in operable elderly patients. METHODS AND RESULTS The study was designed as a randomised controlled trial of a-TAVI (Edwards SAPIEN heart valve system; Edwards Lifesciences, Irvine, CA, USA) vs. SAVR. Operable patients with isolated aortic valve stenosis and an age ≥75 years were included. The primary endpoint was the composite of all-cause mortality, cerebral stroke and/or renal failure requiring haemodialysis at 30 days. After advice from the Data Safety Monitoring Board, the study was prematurely terminated after the inclusion of 70 patients because of an excess of events in the a-TAVI group. The primary endpoint was met in five a-TAVI patients (two deaths, two strokes, and one case of renal failure requiring dialysis) vs. one stroke in the SAVR group (p=0.07). In the a-TAVI group, one patient was converted to SAVR because of an abnormally positioned heart, and four patients were re-operated with open heart surgery because of annulus rupture (n=1), severe paravalvular leakage (n=2), and blockage of the left coronary artery (n=1). In the SAVR group, one patient was converted to TAVI because of a large intra-thoracic goitre. CONCLUSIONS Given the limitations of a small prematurely terminated study, our results suggest that a-TAVI in its present form may be associated with complications and device success rates in low-risk patients similar or even inferior to those found in high-risk patients with aortic valve stenosis. This will probably change in the near future with improved catheter based devices and better pre-procedural assessment.
Collapse
|
38
|
PD-0588: Validation of apparent diffusion coefficient calculation in rectal tumors. Radiother Oncol 2013. [DOI: 10.1016/s0167-8140(15)32894-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
39
|
Transcatheter aortic valve implantation in a patient with circulatory collapse, using the LUCAS® chest compression system. Catheter Cardiovasc Interv 2013; 81:1084-6. [PMID: 23436538 DOI: 10.1002/ccd.24590] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2012] [Accepted: 07/28/2012] [Indexed: 11/09/2022]
Abstract
We describe a case of transcatheter aortic valve implantation (TAVI) using the LUCAS® Chest Compression System in an elderly high risk patient with severe aortic stenosis and heart failure. In this case, the patient developed severe aortic regurgitation following predilatation of the native aortic valve and automated cardiopulmonary resuscitation (A-CPR) was initiated. The procedure was performed under ongoing A-CPR for a total of 28 min. The patient was transferred to the intensive care unit and to a step down unit the following day. At follow-up 30 days later, she showed no signs of neurologic or cardiac damage. This case report shows, that it is possible to perform the TAVI procedure under ongoing A-CPR and that A-CPR, judged by invasive blood pressures, was capable of maintaining a satisfactory perfusion pressure even with a damaged aortic valve.
Collapse
|
40
|
The Nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation: study protocol for a randomised controlled trial. Trials 2013; 14:11. [PMID: 23302232 PMCID: PMC3551839 DOI: 10.1186/1745-6215-14-11] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Accepted: 12/18/2012] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can be offered with improved safety and similar effectiveness in a population including low-risk patients has yet to be examined in a randomised setting. METHODS/DESIGN This randomised clinical trial will evaluate the benefits and risks of TAVI using the transarterial CoreValve System (Medtronic Inc., Minneapolis, MN, USA) (intervention group) compared with SAVR (control group) in patients with severe degenerative AV stenosis. Randomisation ratio is 1:1, enrolling a total of 280 patients aged 70 years or older without significant coronary artery disease and with a low, moderate, or high surgical risk profile. Trial outcomes include a primary composite outcome of myocardial infarction, stroke, or all-cause mortality within the first year after intervention (expected rates 5% for TAVI, 15% for SAVR). Exploratory safety outcomes include procedure complications, valve re-intervention, and cardiovascular death, as well as cardiac, cerebral, pulmonary, renal, and vascular complications. Exploratory efficacy outcomes include New York Heart Association functional status, quality of life, and valve prosthesis and cardiac performance. Enrolment began in December 2009, and 269 patients have been enrolled up to December 2012. DISCUSSION The trial is designed to evaluate the performance of TAVI in comparison with SAVR. The trial results may influence the choice of treatment modality for patients with severe degenerative AV stenosis. TRIAL REGISTRATION ClinicalTrials.gov: NCT01057173.
Collapse
|
41
|
Abstract
Background—
Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.
Methods and Results—
The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients.
Conclusions—
The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Collapse
|
42
|
Survival and growth of Escherichia coli O157:H7, Yersinia enterocolitica and Salmonella enteritidis on decontaminated and untreated meat. Meat Sci 2012; 57:291-8. [PMID: 22061504 DOI: 10.1016/s0309-1740(00)00104-2] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2000] [Revised: 08/14/2000] [Accepted: 08/14/2000] [Indexed: 10/18/2022]
Abstract
Decontamination of meat or carcasses may have an effect in reducing the number of pathogens. Recontamination with other pathogens during cutting or packaging may, however, result in higher growth on decontaminated than on untreated meat due to the lack of competing non-pathogenic microorganisms. In this study we compared the growth of pathogens during storage at 10°C (worst case condition) on untreated meat and meat that had been decontaminated by steam vacuuming combined with spraying with 0.2 M lactic acid. Salmonella enteritidis inoculated on chicken multiplied quickly and reached log 7 cfu per cm(2) after 4 days of aerobic storage at 10°C, but growth was not significantly higher on decontaminated than on untreated chicken. The number of Yersinia enterocolitica inoculated on decontaminated pork skin reached log 9 cfu per cm(2) after 5 days of aerobic storage at 10°C. Overall, growth on vacuum-packed decontaminated and untreated pork under the same conditions was not significantly different, although there tended to be less growth on the untreated samples. The number of Escherichia coli O157:H7 on decontaminated beef increased by nearly 3 log cycles after 5 days of aerobic storage at 10°C compared to only a 1 log cycle increase on untreated beef. For the vacuum-packed beef, growth of E. coli O157:H7 on the fresh meat was very slow, while there was about a 3 log increase on the decontaminated beef. A higher average growth on the decontaminated beef was also found in an experiment with a very low inoculum (27 cfu per cm(2)). During storage of vacuum-packed samples there was multiplication of E. coli O157:H7 on the decontaminated beef, but virtually none on the untreated beef. This study shows that multiplication of S. enteritidis on chicken and Y. enterocolitica on pork skin was not significantly higher on decontaminated compared to untreated meat. The increased multiplication of E. coli O157:H7 on decontaminated beef, especially when vacuum-packed, gives cause for concern. Preventive measures might be a strict HACCP approach to the handling of the decontaminated meat before packaging or use of a protective culture of lactic acid bacteria.
Collapse
|
43
|
TCT-100 Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves: Results from the Global Valve-in-Valve Registry. J Am Coll Cardiol 2012. [DOI: 10.1016/j.jacc.2012.08.116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
44
|
|
45
|
Midterm Evaluation of Hemodynamics of the Top Hat Supraannular Aortic Valve. Asian Cardiovasc Thorac Ann 2010; 18:54-8. [DOI: 10.1177/0218492309355720] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The CarboMedics Top Hat supraannular aortic valve provides an orifice-to-annulus ratio of 1:1 in most patients, and enhances patient outcomes. This study compared the midterm echocardiographic parameters of 52 patients undergoing aortic valve replacement with a Top Hat valve with those in other studies of Top Hat or CarboMedics intraannular valves. Echocardiography was performed 6–48 months after surgery with Top Hat sizes 21-27. Parameters evaluated included mean gradient, peak gradient, effective orifice area, and effective orifice area index. Preoperative and postoperative echocardiographic measurements were compared in 38 patients with aortic valve stenosis. Hemodynamic data were comparable to those of other studies, but the Top Hat prosthesis implanted was significantly larger (by a mean of 3.29 mm) than the valve size indicated using an intraannular valve sizer in 48 patients. Mean effective orifice area improved significantly from 0.73 cm2 preoperatively to 2.04 cm2 postoperatively. In patients with preoperative aortic valve stenosis, postoperative mean peak gradient was significantly reduced. The larger orifice-to-annulus ratio of the Top Hat valve improved hemodynamic parameters assessed by echocardiography up to 4 years postoperatively, with a lower transvalvular gradient, hence decreased left ventricular workload.
Collapse
|
46
|
[Transcatheter aortic valve implantation in Denmark]. Ugeskr Laeger 2009; 171:1076. [PMID: 19321071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
47
|
Prevalence and inter-relationship of different Doppler measures of dyssynchrony in patients with heart failure and prolonged QRS: a report from CARE-HF. Cardiovasc Ultrasound 2009; 7:1. [PMID: 19128462 PMCID: PMC2630933 DOI: 10.1186/1476-7120-7-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2008] [Accepted: 01/07/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cardiac resynchronisation therapy (CRT) improves mortality and morbidity in heart failure patients with wide QRS. Observational studies suggest that patients having more left ventricular dyssynchrony pre-implantation obtain greater benefit on ventricular function and symptoms with CRT. AIM To provide an analysis of the prevalence and type of dyssynchrony in patients included in the CARE-HF trial. METHODS 100 patients 67 (58 to 71) years were examined with echocardiography including tissue doppler imaging before receiving a CRT-pacemaker. Atrio-ventricular dyssynchrony (LVFT/RR) was defined as left ventricular filling time <40% of the RR-interval. Inter-ventricular mechanical delay (IVMD) was measured as the difference in onset of Doppler-flow in the pulmonary and aortic outflow tracts >40 ms. Intra-ventricular (regional) dyssynchrony in a 16-segment model was expressed either as a delayed longitudinal contraction (DLC) during the postsystolic phase or by tissue synchronisation imaging (TSI) with a predefined time-difference in systolic maximal velocities >85 ms. RESULTS LVFT/RR was present in 34% and IVMD in 60% of patients while intra-ventricular dyssynchrony was present in 85% (DLC) and 86% (TSI) with a high agreement between the measures (Kappascore 0.86-1.00), indicating the methods being interchangeable. Patients with cardiomyopathy (53%) were more likely to have LVFT/RR <40% (45% vs. 21% (p= 0.02)) and more segments affected by intra-ventricular dyssynchrony 4(3, 5) vs. 3(1, 4), p = 0.002, compared to patients with ischemic heart disease. CONCLUSION The prevalence of intra-ventricular dyssynchrony is high in patients with heart failure, wide QRS and depressed systolic function. Most important, TSI appears to be a fast and reliable method to identify patients with intra-ventricular dyssynchrony likely to benefit from CRT.
Collapse
|
48
|
Corrigendum to “FH-Freiburg: a novel missense mutation (C317Y) in growth factor repeat A of the low density lipoprotein receptor gene in a German patient with homozygous familial hypercholesterolemia” [Atherosclerosis 151 (2000) 525–534]. Atherosclerosis 2003. [DOI: 10.1016/s0021-9150(02)00186-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
49
|
Abstract
AIMS To assess survival, growth and toxin production of spore-forming bacteria in sous vide products exposed to a relatively high heat treatment. METHODS AND RESULTS During a three-year period, 2,168 sous vide-processed, commercially available ready-made meals with a shelf life of 3-5 weeks were examined. The products were stored at 4 degrees C for the first 1/3 and at 7 degrees C for the remaining 2/3 of their shelf life period. Three-fourths of the samples had less than 10 bacteria per gram the day after production, and none had more than 1,000. Similar numbers were found at the end of the shelf life when stored as described above. At abuse temperature (20 degrees C), the number of bacteria increased to 10(6)-10(7) cfu g(-1) 7 d after production. A total of 350 isolates of Bacillus spp. were collected, but no Clostridium strains were detected. Only 11 of the 113 tested strains were able to grow at 7 degrees C in broth, and none of the psychrotrophic strains were able to produce substantial amounts of toxins causing food poisoning. CONCLUSION The health risk of these products is small as long as the temperature during storage is low. For microbial testing of the end products, traditional plating will suffice.
Collapse
|
50
|
Characterization, production, and purification of carnocin H, a bacteriocin produced by Carnobacterium 377. Curr Microbiol 2001; 43:227-31. [PMID: 11683354 DOI: 10.1007/s002840010292] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Carnocin H, a bacteriocin produced by a Carnobacterium sp., inhibited lactic acid bacteria, clostridia, enterococci, and some Staphylococcus aureus strains. Some strains of Listeria and Pediococcus were also sensitive to carnocin H. The bacteriocin was produced during the late stationary growth phase. Carnocin H was purified by cation exchange chromatography and reverse phase chromatography. Amino acid sequence and composition indicate that carnocin H is a novel bacteriocin belonging to the class II bacteriocins. The bacteriocin consists of approximately 75 amino acid residues with a highly cationic N-terminal containing six succeeding lysines. Activity, as measured by agar diffusion zones, was reduced at increased pH values, levels of indicator bacteria, NaCl, agar, and soy oil.
Collapse
|