1
|
Glans A, Wilén J, Hansson B, Audulv Å, Lindgren L. Managing acoustic noise within MRI: A qualitative interview study among Swedish radiographers. Radiography (Lond) 2024; 30:889-895. [PMID: 38603992 DOI: 10.1016/j.radi.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 03/22/2024] [Accepted: 04/01/2024] [Indexed: 04/13/2024]
Abstract
INTRODUCTION Acoustic noise from magnetic resonance imaging (MRI) can cause hearing loss and needs to be mitigated to ensure the safety of patients and personnel. Capturing MR personnel's insights is crucial for guiding the development and future applications of noise-reduction technology. This study aimed to explore how MR radiographers manage acoustic noise in clinical MR settings. METHODS Using a qualitative design, we conducted semi-structured individual interviews with fifteen MR radiographers from fifteen hospitals around Sweden. We focused on the clinical implications of participants' noise management, using an interpretive description approach. We also identified sociotechnical interactions between People, Environment, Tools, and Tasks (PETT) by adopting a Human Factors/Ergonomics framework. Interview data were analyzed inductively with thematic analysis (Braun and Clarke). RESULTS The analysis generated three main themes regarding MR radiographers' noise management: (I) Navigating Occupational Noise: Risk Management and Adaptation; (II) Protecting the Patient and Serving the Exam, and (III) Establishing a Safe Healthcare Environment with Organizational Support. CONCLUSION This study offers insights into radiographers' experiences of managing acoustic noise within MRI, and the associated challenges. Radiographers have adopted multiple strategies to protect patients and themselves from adverse noise-related effects. However, they require tools and support to manage this effectively, suggesting a need for organizations to adopt more proactive, holistic approaches to safety initiatives. IMPLICATIONS FOR PRACTICE The radiographers stressed the importance of a soundproofed work environment to minimize occupational adverse health effects and preserve work performance. They acknowledge noise as a common contributor to patient distress and discomfort. Providing options like earplugs, headphones, mold putty, software-optimized "quiet" sequences, and patient information were important tools. Fostering a safety culture requires proactive safety efforts and support from colleagues and management.
Collapse
Affiliation(s)
- A Glans
- Department of Nursing, Umeå University, Umeå, Sweden; Department of Diagnostics and Intervention, Radiation Physics, Umeå University, Umeå, Sweden.
| | - J Wilén
- Department of Diagnostics and Intervention, Radiation Physics, Umeå University, Umeå, Sweden
| | - B Hansson
- Department of Clinical Sciences Lund, Diagnostic Radiology, Lund University, Lund, Sweden
| | - Å Audulv
- Department of Nursing, Umeå University, Umeå, Sweden
| | - L Lindgren
- Department of Nursing, Umeå University, Umeå, Sweden
| |
Collapse
|
2
|
Jeschke P, Alteköster C, Hansson Mild K, Israel M, Ivanova M, Schiessl K, Shalamanova T, Soyka F, Stam R, Wilén J. Protection of Workers Exposed to Radiofrequency Electromagnetic Fields: A Perspective on Open Questions in the Context of the New ICNIRP 2020 Guidelines. Front Public Health 2022; 10:875946. [PMID: 35757616 PMCID: PMC9215329 DOI: 10.3389/fpubh.2022.875946] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 03/30/2022] [Indexed: 11/13/2022] Open
Abstract
Workers in occupational settings are usually exposed to numerous sources of electromagnetic fields (EMF) and to different physical agents. Risk assessment for industrial workplaces concerning EMF is not only relevant to operators of devices or machinery emitting EMF, but also to support-workers, bystanders, service and maintenance personnel, and even visitors. Radiofrequency EMF guidelines published in 2020 by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) may also be indirectly applied to assess risks emerging from EMF sources at workplaces by technical standards or legislation. To review the applicability and adequacy to assess exposure to EMF in occupational settings in the European Union, the most current ICNIRP guidelines on radiofrequency EMF are reviewed. Relevant ICNIRP fundamentals and principles are introduced, followed by practical aspects of exposure assessment. To conclude, open questions are formulated pointing out gaps between the guidelines' principles and occupational practice, such as the impact of hot and humid environments and physical activity or controversies around ICNIRPS's reduction factors in view of assessment uncertainty in general. Thus, the article aims to provide scientific policy advisors, labor inspectors, or experts developing standards with a profound understanding about ICNIRP guidelines' applicability to assess hazards related to radiofrequency EMF in occupational settings.
Collapse
Affiliation(s)
- Peter Jeschke
- Federal Institute for Occupational Safety and Health, Dortmund, Germany
| | - Carsten Alteköster
- Institute for Occupational Safety and Health of the German Social Accident Insurance, Sankt Augustin, Germany
| | - Kjell Hansson Mild
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Michel Israel
- National Centre of Public Health and Analyses, Sofia, Bulgaria
| | - Mihaela Ivanova
- National Centre of Public Health and Analyses, Sofia, Bulgaria
| | | | | | - Florian Soyka
- Institute for Occupational Safety and Health of the German Social Accident Insurance, Sankt Augustin, Germany
| | - Rianne Stam
- National Institute for Public Health and the Environment, Bilthoven, Netherlands
| | - Jonna Wilén
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| |
Collapse
|
3
|
Glans A, Wilén J, Lindgren L, Björkman-Burtscher IM, Hansson B. Health effects related to exposure of static magnetic fields and acoustic noise-comparison between MR and CT radiographers. Eur Radiol 2022; 32:7896-7909. [PMID: 35674823 PMCID: PMC9668766 DOI: 10.1007/s00330-022-08843-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 04/21/2022] [Accepted: 04/25/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES We explored the prevalence of health complaints subjectively associated with static magnetic field (SMF) and acoustic noise exposure among MR radiographers in Sweden, using CT radiographers as a control group. Additionally, we explored radiographers' use of strategies to mitigate adverse health effects. METHODS A cross-sectional survey was sent to all hospitals with MR units in Sweden. MR and/or CT personnel reported prevalence and attribution of symptoms (vertigo/dizziness, nausea, metallic taste, illusion of movement, ringing sensations/tinnitus, headache, unusual drowsiness/tiredness, forgetfulness, difficulties concentrating, and difficulties sleeping) within the last year. We used logistic regression to test associations between sex, age, stress, SMF strength, working hours, and symptom prevalence. Data regarding hearing function, work-environmental noise, and strategies to mitigate adverse symptoms were also analysed. RESULTS In total, 529 out of 546 respondents from 86 hospitals were eligible for participation. A ≥ 20 working hours/week/modality cut-off rendered 342 participants grouped into CT (n = 75), MR (n = 121), or mixed personnel (n = 146). No significant differences in symptom prevalence were seen between groups. Working at ≥ 3T increased SMF-associated symptoms as compared with working at ≤ 1.5T (OR: 2.03, CI95: 1.05-3.93). Stress was a significant confounder. Work-related noise was rated as more troublesome by CT than MR personnel (p < 0.01). MR personnel tended to use more strategies to mitigate adverse symptoms. CONCLUSION No significant differences in symptom prevalence were seen between MR and CT radiographers. However, working at 3T increased the risk of SMF symptoms, and stress increased adverse health effects. Noise nuisance was considered more problematic by CT than MR personnel. KEY POINTS • No significant differences in symptom prevalence were seen between MR and CT radiographers. • Working at ≥ 3 T doubled the odds of experiencing SMF symptoms (vertigo/dizziness, nausea, metallic taste, and/or illusion of movement) as compared to working exclusively at ≤ 1.5 T. • Work-related acoustic noise was less well mitigated and was rated as more troublesome by CT personnel than by MR personnel.
Collapse
Affiliation(s)
- Anton Glans
- grid.12650.300000 0001 1034 3451Department of Nursing, Umeå University, Umeå, Sweden ,grid.12650.300000 0001 1034 3451Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Jonna Wilén
- grid.12650.300000 0001 1034 3451Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Lenita Lindgren
- grid.12650.300000 0001 1034 3451Department of Nursing, Umeå University, Umeå, Sweden
| | - Isabella M. Björkman-Burtscher
- grid.8761.80000 0000 9919 9582Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden ,grid.1649.a000000009445082XDepartment of Radiology, Sahlgrenska University Hospital, Västra Götalands Region, Gothenburg, Sweden
| | - Boel Hansson
- grid.411843.b0000 0004 0623 9987Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden ,grid.4514.40000 0001 0930 2361Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
4
|
Glans A, Wilén J, Lindgren L. Maintaining Image Quality While Reducing Acoustic Noise and Switched Gradient Field Exposure During Lumbar MRI. J Magn Reson Imaging 2021; 54:315-325. [PMID: 33565199 DOI: 10.1002/jmri.27527] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/08/2021] [Accepted: 01/09/2021] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND MR-generated acoustic noise can contribute to patient discomfort and potentially be harmful. One way to reduce this noise is by altering the gradient output and/or waveform using software optimization. Such modifications might influence image quality and switched gradient field exposure, and different techniques appear to affect sound pressure levels (SPLs) to various degrees. PURPOSE To evaluate SPLs, image quality, switched gradient field exposure, and participants' perceived noise levels during two different acoustic noise reduction (ANR) techniques, Quiet Suite (QS) and Whisper Mode (WM), and to compare them with conventional T2-weighted turbo spin echo (T2W TSE) of the lumbar spine. DESIGN Prospective. SUBJECTS Forty adults referred for lumbar MRI. FIELD STRENGTH/SEQUENCE Conventional T2W TSE, T2W TSE with QS, and T2W TSE with WM were acquired at 1.5 T. ASSESSMENT Peak SPL (A-weighted decibels, dBA), perceived noise levels (Borg CR10®-scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), three radiologists' qualitative assessments in image quality on an ordinal scale 1-4, switched gradient field exposure (% general public), and gradient currents were measured. Interobserver reliability was reported as percentage agreement. STATISTICAL TESTS Repeated measures ANOVA, Friedman's ANOVA, and Wilcoxon's Signed-Rank Test for acoustic noise measurements and image quality assessments. RESULTS Mean peak SPLs were 89.9 dBA, 74.3 dBA, and 78.8 dBA for conventional, QS, and WM, respectively (P < 0.05). Participants perceived QS as the quietest and conventional as the loudest sequence (P < 0.05). No qualitative differences in image quality were seen (P > 0.05), although QS showed significantly improved SNR and CNR (P < 0.05). Switched gradient field exposure was reduced by 66% and 48% for QS and WM, respectively. DATA CONCLUSION Without degrading image quality, both QS and WM are viable ANR techniques in lumbar T2W TSE. QS provided the lowest SPL, the lowest gradient field exposure and was perceived as the most silent among the three sequences. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE: 5.
Collapse
Affiliation(s)
- Anton Glans
- Department of Nursing, Umeå University, Umeå, Sweden.,Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Jonna Wilén
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | | |
Collapse
|
5
|
Wilén J, Olsrud J, Frankel J, Hansson Mild K. Valid Exposure Protocols Needed in Magnetic Resonance Imaging Genotoxic Research. Bioelectromagnetics 2020; 41:247-257. [PMID: 32157722 DOI: 10.1002/bem.22257] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 02/22/2020] [Indexed: 11/10/2022]
Abstract
Several in vitro and in vivo studies have investigated if a magnetic resonance imaging (MRI) examination can cause DNA damage in human blood cells. However, the electromagnetic field (EMF) exposure that the cells received in the MR scanner was not sufficiently described. The first studies looking into this could be regarded as hypothesis-generating studies. However, for further exploration into the role of MRI exposure on DNA integrity, the exposure itself cannot be ignored. The lack of sufficient method descriptions makes the early experiments difficult, if not impossible, to repeat. The golden rule in all experimental work is that a study should be repeatable by someone with the right knowledge and equipment, and this is simply not the case with many of the recent studies on MRI and genotoxicity. Here we discuss what is lacking in previous studies, and how we think the next generation of in vitro and in vivo studies on MRI and genotoxicity should be performed. Bioelectromagnetics. © 2020 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Jonna Wilén
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Johan Olsrud
- Department of Diagnostic Radiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Jennifer Frankel
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Kjell Hansson Mild
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| |
Collapse
|
6
|
Hansson Mild K, Lundström R, Wilén J. Non-Ionizing Radiation in Swedish Health Care-Exposure and Safety Aspects. Int J Environ Res Public Health 2019; 16:E1186. [PMID: 30987016 PMCID: PMC6479478 DOI: 10.3390/ijerph16071186] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 03/26/2019] [Accepted: 03/28/2019] [Indexed: 12/13/2022]
Abstract
The main aim of the study was to identify and describe methods using non-ionizing radiation (NIR) such as electromagnetic fields (EMF) and optical radiation in Swedish health care. By examining anticipated exposure levels and by identifying possible health hazards we also aimed to recognize knowledge gaps in the field. NIR is mainly used in health care for diagnosis and therapy. Three applications were identified where acute effects cannot be ruled out: magnetic resonance imaging (MRI), transcranial magnetic stimulation (TMS) and electrosurgery. When using optical radiation, such as class 3 and 4 lasers for therapy or surgical procedures and ultra-violet light for therapy, acute effects such as unintentional burns, photo reactions, erythema and effects on the eyes need to be avoided. There is a need for more knowledge regarding long-term effects of MRI as well as on the combination of different NIR exposures. Based on literature and after consulting staff we conclude that the health care professionals' knowledge about the risks and safety measures should be improved and that there is a need for clear, evidence-based information from reliable sources, and it should be obvious to the user which source to address.
Collapse
Affiliation(s)
- Kjell Hansson Mild
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| | - Ronnie Lundström
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| | - Jonna Wilén
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| |
Collapse
|
7
|
Hansson B, Höglund P, Markenroth Bloch K, Nilsson M, Olsrud J, Wilén J, Björkman-Burtscher IM. Short-term effects experienced during examinations in an actively shielded 7 T MR. Bioelectromagnetics 2019; 40:234-249. [PMID: 30920671 PMCID: PMC6593459 DOI: 10.1002/bem.22189] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 03/12/2019] [Indexed: 01/18/2023]
Abstract
The objective of this study was to evaluate occurrence and strength of short-term effects experienced by study participants in an actively shielded (AS) 7 tesla (7 T) magnetic resonance (MR) scanner, to compare results with earlier reports on passively shielded (PS) 7 T MR scanners, and to outline possible healthcare strategies to improve patient compliance. Study participants (n = 124) completed a web-based questionnaire directly after being examined in an AS 7 T MR (n = 154 examinations). Most frequently experienced short-term effects were dizziness (84%) and inconsistent movement (70%), especially while moving into or out of the magnet. Peripheral nerve stimulation (PNS)-twitching-was experienced in 67% of research examinations and showed a dependence between strength of twitches and recorded predicted PNS values. Of the participants, 74% experienced noise levels as acceptable and the majority experienced body and room temperature as comfortable. Of the study participants, 95% felt well-informed and felt they had had good contact with the staff before the examination. Willingness to undergo a future 7 T examination was high (>90%). Our study concludes short-term effects are often experienced during examinations in an AS 7 T MR, leaving room for improvement in nursing care strategies to increase patient compliance. Bioelectromagnetics. 2019;9999:XX-XX. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Boel Hansson
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Peter Höglund
- Department of Clinical Pharmacology, Lund University, Lund, Sweden
| | | | - Markus Nilsson
- Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Johan Olsrud
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Jonna Wilén
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Isabella M Björkman-Burtscher
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden.,Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
8
|
Frankel J, Hansson Mild K, Olsrud J, Wilén J. EMF exposure variation among MRI sequences from pediatric examination protocols. Bioelectromagnetics 2019; 40:3-15. [PMID: 30500987 PMCID: PMC6587721 DOI: 10.1002/bem.22159] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 10/30/2018] [Indexed: 11/18/2022]
Abstract
The magnetic resonance imaging (MRI) exposure environment is unique due to the mixture and intensity of magnetic fields involved. Current safety regulations are based on well-known acute effects of heating and neuroexcitation while the scientific grounds for possible long-term effects from MRI exposure are lacking. Epidemiological research requires careful exposure characterization, and as a first step toward improved exposure assessment we set out to characterize the MRI-patient exposure environment. Seven MRI sequences were run on a 3-Tesla scanner while the radiofrequency and gradient magnetic fields were measured inside the scanner bore. The sequences were compared in terms of 14 different exposure parameters. To study within-sequence variability, we varied sequence settings such as flip angle and slice thickness one at a time, to determine if they had any impact on exposure endpoints. There were significant differences between two or more sequences for all fourteen exposure parameters. Within-sequence differences were up to 60% of the corresponding between-sequence differences, and a 5-8 fold exposure increase was caused by variations in flip angle, slice spacing, and field of view. MRI exposure is therefore not only sequence-specific but also patient- and examination occurrence-specific, a complexity that requires careful consideration for an MRI exposure assessment in epidemiological studies to be meaningful. Bioelectromagnetics. 40:3-15, 2019. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Jennifer Frankel
- Department of Radiation SciencesRadiation PhysicsUmeå UniversityUmeåSweden
| | - Kjell Hansson Mild
- Department of Radiation SciencesRadiation PhysicsUmeå UniversityUmeåSweden
| | - Johan Olsrud
- Center for Medical Imaging and PhysiologySkåne University HospitalLundSweden
| | - Jonna Wilén
- Department of Radiation SciencesRadiation PhysicsUmeå UniversityUmeåSweden
| |
Collapse
|
9
|
Frankel J, Wilén J, Hansson Mild K. Assessing Exposures to Magnetic Resonance Imaging's Complex Mixture of Magnetic Fields for In Vivo, In Vitro, and Epidemiologic Studies of Health Effects for Staff and Patients. Front Public Health 2018; 6:66. [PMID: 29594090 PMCID: PMC5858533 DOI: 10.3389/fpubh.2018.00066] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 02/19/2018] [Indexed: 12/15/2022] Open
Abstract
A complex mixture of electromagnetic fields is used in magnetic resonance imaging (MRI): static, low-frequency, and radio frequency magnetic fields. Commonly, the static magnetic field ranges from one to three Tesla. The low-frequency field can reach several millitesla and with a time derivative of the order of some Tesla per second. The radiofrequency (RF) field has a magnitude in the microtesla range giving rise to specific absorption rate values of a few Watts per kilogram. Very little attention has been paid to the case where there is a combined exposure to several different fields at the same time. Some studies have shown genotoxic effects in cells after exposure to an MRI scan while others have not demonstrated any effects. A typical MRI exam includes muliple imaging sequences of varying length and intensity, to produce different types of images. Each sequence is designed with a particular purpose in mind, so one sequence can, for example, be optimized for clearly showing fat water contrast, while another is optimized for high-resolution detail. It is of the utmost importance that future experimental studies give a thorough description of the exposure they are using, and not just a statement such as “An ordinary MRI sequence was used.” Even if the sequence is specified, it can differ substantially between manufacturers on, e.g., RF pulse height, width, and duty cycle. In the latest SCENIHR opinion, it is stated that there is very little information regarding the health effects of occupational exposure to MRI fields, and long-term prospective or retrospective cohort studies on workers are recommended as a high priority. They also state that MRI is increasingly used in pediatric diagnostic imaging, and a cohort study into the effects of MRI exposure on children is recommended as a high priority. For the exposure assessment in epidemiological studies, there is a clear difference between patients and staff and further work is needed on this. Studies that explore the possible differences between MRI scan sequences and compare them in terms of exposure level are warranted.
Collapse
Affiliation(s)
- Jennifer Frankel
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Jonna Wilén
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Kjell Hansson Mild
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| |
Collapse
|
10
|
Hansson Mild K, Friberg S, Frankel J, Wilén J. Exposure to the magnetic field from an induction loop pad for a hearing aid system. Int J Occup Saf Ergon 2016; 23:143-145. [PMID: 27541365 DOI: 10.1080/10803548.2016.1226597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
As a case study we have measured the magnetic field from an induction loop pad designed for hearing aid assistance. The magnitude of the field was high, although well below international guidelines. We recorded values up to 70% of the recommended standard in some instances. However, in view of the many reports indicating health effects of low-level exposure, we recommend that the precautionary principle is applied when such pads are given to people who might be especially vulnerable, such as children, pregnant women and women on breast cancer medication.
Collapse
Affiliation(s)
| | - Stefan Friberg
- b Department of Audiology , University Hospital of Umeå , Sweden
| | | | - Jonna Wilén
- a Department of Radiation Sciences , Umeå University , Sweden
| |
Collapse
|
11
|
Sundström H, Mild KH, Wilén J. Measurements of the ripple effect and geometric distribution of switched gradient fields inside a magnetic resonance scanner. Bioelectromagnetics 2014; 36:162-8. [PMID: 25399749 DOI: 10.1002/bem.21884] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 09/18/2014] [Indexed: 11/09/2022]
Abstract
Knowledge of patient exposure during magnetic resonance imaging (MRI) procedures is limited, and the need for such knowledge has been demonstrated in recent in vitro and in vivo studies of the genotoxic effects of MRI. This study focuses on the dB/dt of the switched gradient field (SGF) and its geometric distribution. These values were characterized by measuring the peak dB/dt generated by a programmed gradient current of alternating triangles inside a 1.5T MR scanner. The maximum dB/dt exposure to the gradient field was 6-14 T/s, and this occurred at the edges of the field of view (FOV) 20-25 cm from the isocenter in the longitudinal direction. The dB/dt exposure dropped off to roughly half the maximum (3-7 T/s) at the edge of the bore. It was found that the dB/dt of the SGF was distorted by a 200 kHz ripple arising from the amplifier. The ripple is small in terms of B-field, but the high frequency content contributes to a peak dB/dt up to 18 times larger than that predicted by the slew rate (4 T/s m) and the distance from the isocenter. Measurements on a 3 T MRI scanner, however, revealed a much smaller filtered ripple of 100 kHz in dB/dt. These findings suggest that the gradient current to each coil together with information on the geometrical distribution of the gradient field and ripple effects could be used to assess the SGF exposure within an MRI bore.
Collapse
|
12
|
Hansson Mild K, Hand J, Hietanen M, Gowland P, Karpowicz J, Keevil S, Lagroye I, van Rongen E, Scarfi MR, Wilén J. Exposure classification of MRI workers in epidemiological studies. Bioelectromagnetics 2012; 34:81-4. [PMID: 22532229 DOI: 10.1002/bem.21728] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2011] [Accepted: 03/23/2012] [Indexed: 11/06/2022]
Abstract
We estimate that there are about 100,000 workers from different disciplines, such as radiographers, nurses, anesthetists, technicians, engineers, etc., who can be exposed to substantial electromagnetic fields (compared to normal background levels) around magnetic resonance imaging (MRI) scanners. There is a need for well-designed epidemiological studies of MRI workers but since the exposure from MRI equipment is a very complex mixture of static magnetic fields, switched gradient magnetic fields, and radiofrequency electromagnetic fields (RF EMF), it is necessary to discuss how to assess the exposure in epidemiological studies. As an alternative to the use of job title as a proxy of exposure, we propose an exposure categorization for the different professions working with MRI equipment. Specifically, we propose defining exposure in three categories, depending on whether people are exposed to only the static field, to the static plus switched gradient fields or to the static plus switched gradient plus RF fields, as a basis for exposure assessment in epidemiological studies.
Collapse
|
13
|
|
14
|
Wilén J, Hauksson J, Mild KH. Modification of pulse sequences reduces occupational exposure from MRI switched gradient fields: Preliminary results. Bioelectromagnetics 2010; 31:85-7. [PMID: 19753611 DOI: 10.1002/bem.20544] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The gradient fields in magnetic resonance imaging (MRI) will in some circumstances exceed the ICNIRP guidelines of occupational electromagnetic field exposure when personnel are near the scanner during MRI scanning. In this work we have shown that using commercially available modified sequences for noise reduction purposes, exposure will decrease by a factor of 1.5 with preserved image quality. This is a first step toward optimizing occupational exposure within the scanner room without affecting image quality.
Collapse
Affiliation(s)
- Jonna Wilén
- Department of Radiation Sciences, Umeå University, Umeå, Sweden.
| | | | | |
Collapse
|
15
|
Mild KH, Wilén J, Mattsson MO, Simko M. Background ELF magnetic fields in incubators: A factor of importance in cell culture work. Cell Biol Int 2009; 33:755-7. [DOI: 10.1016/j.cellbi.2009.04.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2008] [Revised: 03/04/2009] [Accepted: 04/14/2009] [Indexed: 10/20/2022]
|
16
|
Johansson A, Forsgren S, Stenberg B, Wilén J, Kalezic N, Sandström M. No effect of mobile phone-like RF exposure on patients with atopic dermatitis. Bioelectromagnetics 2008; 29:353-62. [DOI: 10.1002/bem.20402] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
Straume A, Johnsson A, Oftedal G, Wilén J. Frequency spectra from current vs. magnetic flux density measurements for mobile phones and other electrical appliances. Health Phys 2007; 93:279-87. [PMID: 17846524 DOI: 10.1097/01.hp.0000266739.54093.9f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
The frequency spectra of electromagnetic fields have to be determined to evaluate human exposure in accordance to ICNIRP guidelines. In the literature, comparisons with magnetic field guidelines have been performed by using the frequency distribution of the current drawn from the battery. In the present study we compared the frequency spectrum in the range 217 Hz to 2.4 kHz of the magnetic flux density measured near the surface of a mobile phone with the frequency spectrum of the supply current. By using the multiple frequency rule, recommended in the ICNIRP guidelines, we estimated the magnetic field exposure in the two cases. Similar measurements and estimations were done for an electric drill, a hair dryer, and a fluorescent desk lamp. All the devices have a basic frequency of 50 Hz, and the frequency spectra were evaluated up to 550 Hz. We also mapped the magnetic field in 3D around three mobile phones. The frequency distributions obtained from the two measurement methods are not equal. The frequency content of the current leads to an overestimation of the magnetic field exposure by a factor up to 2.2 for the mobile phone. For the drill, the hair dryer, and the fluorescent lamp, the supply current signal underestimated the exposure by a factor up to 2.3. In conclusion, an accurate exposure evaluation requires the magnetic flux density spectrum of the device to be measured directly. There was no indication that the devices studied would exceed the reference levels at the working distances normally used.
Collapse
Affiliation(s)
- Aksel Straume
- Department of Physics, Norwegian University of Science and Technology (NTNU), N-7491 Trondheim, Norway.
| | | | | | | |
Collapse
|
18
|
Wilén J, Johansson A, Kalezic N, Lyskov E, Sandström M. Psychophysiological tests and provocation of subjects with mobile phone related symptoms. Bioelectromagnetics 2006; 27:204-14. [PMID: 16304699 DOI: 10.1002/bem.20195] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The aim of the present study was to investigate the effect of exposure to a mobile phone-like radiofrequency (RF) electromagnetic field on persons experiencing subjective symptoms when using mobile phones (MP). Twenty subjects with MP-related symptoms were recruited and matched with 20 controls without MP-related symptoms. Each subject participated in two experimental sessions, one with true exposure and one with sham exposure, in random order. In the true exposure condition, the test subjects were exposed for 30 min to an RF field generating a maximum SAR(1g) in the head of 1 W/kg through an indoor base station antenna attached to a 900 MHz GSM MP. The following physiological and cognitive parameters were measured during the experiment: heart rate and heart rate variability (HRV), respiration, local blood flow, electrodermal activity, critical flicker fusion threshold (CFFT), short-term memory, and reaction time. No significant differences related to RF exposure conditions were detected. Also no differences in baseline data were found between subject groups, except for the reaction time, which was significantly longer among the cases than among the controls the first time the test was performed. This difference disappeared when the test was repeated. However, the cases differed significantly from the controls with respect to HRV as measured in the frequency domain. The cases displayed a shift in low/high frequency ratio towards a sympathetic dominance in the autonomous nervous system during the CFFT and memory tests, regardless of exposure condition. This might be interpreted as a sign of differences in the autonomous nervous system regulation between persons with MP related subjective symptoms and persons with no such symptoms.
Collapse
Affiliation(s)
- Jonna Wilén
- National Institute for Working Life, Umeå, Sweden
| | | | | | | | | |
Collapse
|
19
|
Abstract
In a previous study, we showed that operators of radiofrequency (RF) plastic sealers, RF operators (n = 35) had a lower heart rate during nighttime compared to a control group (n = 37). We have analyzed the heart rate variability (HRV) on the same group of people to better understand the possible underlying rhythm disturbances. We found a significantly increased total HRV and very low frequency (VLF) power during nighttime among the RF operators compared to a control group. Together with our previous finding of a significantly lower heart rate during nighttime among the RF operators compared to the controls, this finding indicates a relative increase in parasympathetic cardiac modulation in RF operators. This could in turn be due to an adaptation of the thermoregulatory system and the cardiac autonomic modulation to a long-term low-level thermal exposure in the RF operators.
Collapse
Affiliation(s)
- Jonna Wilén
- National Institute for Working Life, Umeå, Sweden.
| | | | | | | |
Collapse
|
20
|
Hansson Mild K, Carlberg M, Wilén J, Hardell L. How to combine the use of different mobile and cordless telephones in epidemiological studies on brain tumours? Eur J Cancer Prev 2005; 14:285-8. [PMID: 15902000 DOI: 10.1097/00008469-200506000-00015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Mobile phone users in epidemiological studies have often used more than one phone model, and sometimes also more than one mobile phone system (analogue and digital systems). Until now, this has not been taken into account in epidemiological studies, mainly because we do not know the possible interaction mechanism(s) and, hence, how to integrate exposure from different phones into one dosimetric measure. In this paper we take a step towards starting a discussion about how to proceed with this important issue and the possible use of parameters such as weighting factors, measured specific absorption rate (SAR) values and integrated specific absorption values are discussed. As a base of this discussion two previously published studies are used, one on mobile phones and cancer and the other one on subjective symptoms.
Collapse
|
21
|
Wilén J, Hörnsten R, Sandström M, Bjerle P, Wiklund U, Stensson O, Lyskov E, Mild KH. Electromagnetic field exposure and health among RF plastic sealer operators. Bioelectromagnetics 2003; 25:5-15. [PMID: 14696048 DOI: 10.1002/bem.10154] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Operators of RF plastic sealers (RF operators) are an occupational category highly exposed to radiofrequency electromagnetic fields. The aim of the present study was to make an appropriate exposure assessment of RF welding and examine the health status of the operators. In total, 35 RF operators and 37 controls were included. The leakage fields (electric and magnetic field strength) were measured, as well as induced and contact current. Information about welding time and productivity was used to calculate time integrated exposure. A neurophysiological examination and 24 h ECG were also carried out. The participants also had to answer a questionnaire about subjective symptoms. The measurements showed that RF operators were exposed to rather intense electric and magnetic fields. The mean values of the calculated 6 min, spatially averaged E and H field strengths, in line with ICNIRP reference levels, are 107 V/m and 0.24 A/m, respectively. The maximum measured field strengths were 2 kV/m and 1.5 A/m, respectively. The induced current in ankles and wrists varied, depending on the work situation, with a mean value of 101 mA and a maximum measured value of 1 A. In total, 11 out of 46 measured RF plastic sealers exceeded the ICNIRP reference levels. RF operators, especially the ready made clothing workers had a slightly disturbed two-point discrimination ability compared to a control group. A nonsignificant difference between RF operators and controls was found in the prevalence of subjective symptoms, but the time integrated exposure parameters seem to be of importance to the prevalence of some subjective symptoms: fatigue, headaches, and warmth sensations in the hands. Further, RF operators had a significantly lower heart rate (24 h registration) and more episodes of bradycardia compared to controls.
Collapse
Affiliation(s)
- Jonna Wilén
- National Institute for Working Life, Umeå, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Wilén J, Sandström M, Hansson Mild K. Subjective symptoms among mobile phone users--a consequence of absorption of radiofrequency fields? Bioelectromagnetics 2003; 24:152-9. [PMID: 12669297 DOI: 10.1002/bem.10101] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a previous epidemiological study, where we studied the prevalence of subjective symptoms among mobile phone (MP) users, we found as an interesting side finding that the prevalence of many of the subjective symptoms increased with increasing calling time and number of calls per day. In this extrapolative study, we have selected 2402 people from the epidemiological study who used any of the four most common GSM MP. We used the information about the prevalence of symptoms, calling time per day, and number of calls per day and combined it with measurements of the Specific Absorption Rate (SAR). We defined three volumes in the head and measured the maximum SAR averaged over a cube of 1 g tissue (SAR(1g)) in each volume. Two new exposure parameters Specific Absorption per Day (SAD) and Specific Absorption per Call (SAC) have been devised and are obtained as combinations of SAR, calling time per day, and number of calls per day, respectively. The results indicates that SAR values >0.5 W/kg may be an important factor for the prevalence of some of the symptoms, especially in combination with long calling times per day.
Collapse
Affiliation(s)
- Jonna Wilén
- National Institute for Working Life, Umeå, Sweden.
| | | | | |
Collapse
|
23
|
Wilén J, Mild KH, Paulsson LE, Anger G. Induced current measurements in whole body exposure condition to radio frequency electric fields. Bioelectromagnetics 2001; 22:560-7. [PMID: 11748673 DOI: 10.1002/bem.84] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The current induced in a human exposed to radio frequency electric fields has been studied by the use of a stripline, in which whole body exposure to vertical electric fields (3-27 MHz) can be produced. We have examined two different techniques to measure the induced current; parallel plate meters and current probes. When the subject has good connection to the ground, the choice of measurement technique is not crucial, since there are only minor differences in readings between the instruments. But when the subject is wearing shoes and/or standing on a wooden plate, the difference between the instruments increases considerably. The difference can mainly be explained by the capacitive coupling between the parallel plate meters and the ground; therefore, the current probes are preferred when the subject does not have perfect contact with the ground. Since the International Commission on Non-Ionizing Radiation Protection guidelines demand measurements of induced current in humans exposed to radio frequency fields in the range of 10-110 MHz, the importance of finding an appropriate measurement procedure becomes apparent.
Collapse
Affiliation(s)
- J Wilén
- National Institute for Working Life, Box 7654 S-907 13 Umeå, Sweden.
| | | | | | | |
Collapse
|
24
|
Nordenson I, Mild KH, Järventaus H, Hirvonen A, Sandström M, Wilén J, Blix N, Norppa H. Chromosomal aberrations in peripheral lymphocytes of train engine drivers. Bioelectromagnetics 2001; 22:306-15. [PMID: 11424153 DOI: 10.1002/bem.55] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Studies of Swedish railway employees have indicated that railroad engine drivers have an increased cancer morbidity and incidence of chronic lymphatic leukemia. The drivers are exposed to relatively high magnetic fields (MF), ranging from a few to over a hundred microT. Although the possible genotoxic potential of MF is unclear, some earlier studies have indicated that occupational exposure to MF may increase chromosome aberrations in blood lymphocytes. Since an increased level of chromosomal aberrations has been suggested to predict elevated cancer risk, we performed a cytogenetic analysis on cultured (48 h) peripheral lymphocytes of Swedish train engine drivers. A pilot study of 18 engine drivers indicated a significant difference in the frequency of cells with chromosomal aberrations (gaps included or excluded) in comparison with seven concurrent referents (train dispatchers) and a control group of 16 office workers. The engine drivers had about four times higher frequency of cells with chromosome-type aberrations (excluding gaps) than the office workers (P < 0.01) and the dispatchers (P < 0.05). Seventy-eight percent of the engine drivers showed at least one cell per 100 with chromosome-type aberrations compared with 29% among the dispatchers and 31% among the office workers. In a follow-up study, another 30 engine drivers showed an increase (P < 0.05) in the frequency of cells with chromosome-type aberrations (gaps excluded) as compared with 30 referent policemen. Sixty percent of the engine drivers had one or more cells (per 100 cells) with chromosome-type aberrations compared with 30% among the policemen. In conclusion, the results of the two studies support the hypothesis that exposure to MF at mean intensities of 2-15 microT can induce chromosomal damage.
Collapse
Affiliation(s)
- I Nordenson
- National Institute for Working Life, Umeå, Sweden
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Abstract
Many people in Norway and Sweden reported headaches, fatigue, and other symptoms experienced in connection with the use of a mobile phone (MP). Therefore, we initiated a cross-sectional epidemiological study among 17,000 people, all using an MP in their job. Thirty-one percent of the respondents in Norway and 13% of those in Sweden had experienced at least one symptom in connection with MP use. Next to the sensations of warmth on the ear and behind/around the ear, burning sensations in the facial skin and headaches were most commonly reported. Most symptoms usually began during or within half an hour after the call and lasted for up to 2 h. Relatively few had consulted a physician or been on sick leave because of the symptoms, but about 45% among those with an MP attributed symptom had taken steps to reduce the symptom. These results suggest an awareness of the symptoms, but not necessarily a serious health problem.
Collapse
|