1
|
Using Compound Neural Action Potentials for Functional Validation of a High-Density Intraneural Interface: A Preliminary Study. MICROMACHINES 2024; 15:280. [PMID: 38399008 PMCID: PMC10891740 DOI: 10.3390/mi15020280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/14/2024] [Accepted: 02/15/2024] [Indexed: 02/25/2024]
Abstract
Compound nerve action potentials (CNAPs) were used as a metric to assess the stimulation performance of a novel high-density, transverse, intrafascicular electrode in rat models. We show characteristic CNAPs recorded from distally implanted cuff electrodes. Evaluation of the CNAPs as a function of stimulus current and calculation of recruitment plots were used to obtain a qualitative approximation of the neural interface's placement and orientation inside the nerve. This method avoids elaborate surgeries required for the implantation of EMG electrodes and thus minimizes surgical complications and may accelerate the healing process of the implanted subject.
Collapse
|
2
|
Subdiaphragmatic vagal nerve stimulation attenuates the development of hypertension and alters nucleus of the solitary tract transcriptional networks in the spontaneously hypertensive rat. Physiol Genomics 2023; 55:606-617. [PMID: 37746712 DOI: 10.1152/physiolgenomics.00016.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 08/18/2023] [Accepted: 09/18/2023] [Indexed: 09/26/2023] Open
Abstract
Augmented vagal signaling may be therapeutic in hypertension. Most studies to date have used stimulation of the cervical vagal branches. Here, we investigated the effects of chronic intermittent electric stimulation of the ventral subdiaphragmatic vagal nerve branch (sdVNS) on long-term blood pressure, immune markers, and gut microbiota in the spontaneously hypertensive rat (SHR), a rodent model of hypertension characterized by vagal dysfunction, gut dysbiosis, and low-grade inflammation. We evaluated the effects of sdVNS on transcriptional networks in the nucleus of the solitary tract (NTS), a major cardioregulatory brain region with direct gut vagal projections. Male juvenile SHRs were implanted with radiotelemetry transmitters and vagal nerve cuffs for chronic intermittent electric sdVNS, applied three times per day for 7 consecutive weeks followed by 1 wk of no stimulation. Blood pressure was measured once a week using telemetry in the sdVNS group as well as age-matched sham-stimulated SHR controls. At the endpoint, colonic and circulating inflammatory markers, corticosterone, and circulating catecholamines were investigated. Bacterial 16 s sequencing measured gut bacterial abundance and composition. RNA sequencing evaluated the effects of sdVNS on transcriptional networks in the NTS. SHRs that received sdVNS exhibited attenuated development of hypertension compared with sham animals. No changes in peripheral inflammatory markers, corticosterone, or catecholamines and no major differences in gut bacterial diversity and composition were observed following sdVNS, apart from decreased abundance of Defluviitaleaceale bacterium detected in sdVNS SHRs compared with sham animals. RNA sequencing revealed significant sdVNS-dependent modulation of select NTS transcriptional networks, including catecholaminergic and corticosteroid networks.NEW & NOTEWORTHY We show that stimulation of the ventral subdiaphragmatic vagal nerve branch may be a promising potential approach to treating hypertension. The data are especially encouraging given that rodents received only 30 min per day of intermittent stimulation therapy and in view of the potential of long-term blood pressure effects that are not stimulus-locked.
Collapse
|
3
|
High frequency alternating current neurostimulation decreases nocifensive behavior in a disc herniation model of lumbar radiculopathy. Bioelectron Med 2023; 9:15. [PMID: 37434246 DOI: 10.1186/s42234-023-00119-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 06/19/2023] [Indexed: 07/13/2023] Open
Abstract
BACKGROUND The purpose of this study was to evaluate if kilohertz frequency alternating current (KHFAC) stimulation of peripheral nerve could serve as a treatment for lumbar radiculopathy. Prior work shows that KHFAC stimulation can treat sciatica resulting from chronic sciatic nerve constriction. Here, we evaluate if KHFAC stimulation is also beneficial in a more physiologic model of low back pain which mimics nucleus pulposus (NP) impingement of a lumbar dorsal root ganglion (DRG). METHODS To mimic a lumbar radiculopathy, autologous tail NP was harvested and placed upon the right L5 nerve root and DRG. During the same surgery, a cuff electrode was implanted around the sciatic nerve with wires routed to a headcap for delivery of KHFAC stimulation. Male Lewis rats (3 mo., n = 18) were separated into 3 groups: NP injury + KHFAC stimulation (n = 7), NP injury + sham cuff (n = 6), and sham injury + sham cuff (n = 5). Prior to surgery and for 2 weeks following surgery, animal tactile sensitivity, gait, and static weight bearing were evaluated. RESULTS KHFAC stimulation of the sciatic nerve decreased behavioral evidence of pain and disability. Without KHFAC stimulation, injured animals had heightened tactile sensitivity compared to baseline (p < 0.05), with tactile allodynia reversed during KHFAC stimulation (p < 0.01). Midfoot flexion during locomotion was decreased after injury but improved with KHFAC stimulation (p < 0.05). Animals also placed more weight on their injured limb when KHFAC stimulation was applied (p < 0.05). Electrophysiology measurements at end point showed decreased, but not blocked, compound nerve action potentials with KHFAC stimulation (p < 0.05). CONCLUSIONS KHFAC stimulation decreases hypersensitivity but does not cause additional gait compensations. This supports the idea that KHFAC stimulation applied to a peripheral nerve may be able to treat chronic pain resulting from sciatic nerve root inflammation.
Collapse
|
4
|
The effects of targeted vagus nerve stimulation on glucose homeostasis in STZ-induced diabetic rodents. Front Neurosci 2023; 17:1179276. [PMID: 37397461 PMCID: PMC10309008 DOI: 10.3389/fnins.2023.1179276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/15/2023] [Indexed: 07/04/2023] Open
Abstract
During type 1 diabetes, an autoimmune attack destroys pancreatic β-cells leading to the inability to maintain glucose homeostasis. These β-cells are neuroresponsive endocrine cells which normally secrete insulin partially in response to input from the vagus nerve. This neural pathway can be utilized as a point of therapeutic intervention by delivering exogenous stimulation to drive increased insulin secretion. In this study, a cuff electrode was implanted on the pancreatic branch of the vagus nerve just prior to pancreatic insertion in rats, and a continuous glucose meter was implanted into the descending aorta. Streptozotocin (STZ) was used to induce a diabetic state, and changes in blood glucose were assessed using various stimulation parameters. Stimulation driven changes in hormone secretion, pancreatic blood flow, and islet cell populations were assessed. We found increased changes in the rate of blood glucose change during stimulation which subsided after stimulation ended paired with increased concentration of circulating insulin. We did not observe increased pancreatic perfusion, which suggests that the modulation of blood glucose was due to the activation of b-cells rather than changes in the extra-organ transport of insulin. Pancreatic neuromodulation showed potentially protective effects by reducing deficits in islet diameter, and ameliorating insulin loss after STZ treatment.
Collapse
|
5
|
Layer-dependent stability of intracortical recordings and neuronal cell loss. Front Neurosci 2023; 17:1096097. [PMID: 37090803 PMCID: PMC10113640 DOI: 10.3389/fnins.2023.1096097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 03/13/2023] [Indexed: 04/08/2023] Open
Abstract
Intracortical recordings can be used to voluntarily control external devices via brain-machine interfaces (BMI). Multiple factors, including the foreign body response (FBR), limit the stability of these neural signals over time. Current clinically approved devices consist of multi-electrode arrays with a single electrode site at the tip of each shank, confining the recording interface to a single layer of the cortex. Advancements in manufacturing technology have led to the development of high-density electrodes that can record from multiple layers. However, the long-term stability of neural recordings and the extent of neuronal cell loss around the electrode across different cortical depths have yet to be explored. To answer these questions, we recorded neural signals from rats chronically implanted with a silicon-substrate microelectrode array spanning the layers of the cortex. Our results show the long-term stability of intracortical recordings varies across cortical depth, with electrode sites around L4-L5 having the highest stability. Using machine learning guided segmentation, our novel histological technique, DeepHisto, revealed that the extent of neuronal cell loss varies across cortical layers, with L2/3 and L4 electrodes having the largest area of neuronal cell loss. These findings suggest that interfacing depth plays a major role in the FBR and long-term performance of intracortical neuroprostheses.
Collapse
|
6
|
High Frequency Alternating Current Stimulation Applied To A Peripheral Nerve Can Treat Sciatica Resulting From A Herniated Lumbar Disc. THE JOURNAL OF PAIN 2023. [DOI: 10.1016/j.jpain.2023.02.157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
|
7
|
Electrochemistry in Action-Engineering the Neuronal Response to Electrical Microstimulation. ELECTROCHEMICAL SOCIETY INTERFACE 2023. [DOI: 10.1149/2.f06231if] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
Brain neuromodulation has revolutionized the medical treatment of neurological diseases and injuries; however, existing therapies are limited in their clinical scope of application. Most existing therapies are delivered through implanted macroelectrodes that reside either on top of or directly inside the brain. Estimates of the effective electric field spread from these devices generally span from thousands to millions of individual neurons. Unfortunately, some neurological diseases and injuries require stimulation fields of higher precision. Next-generation microneuromodulation devices (˜102 – 103 μm2 surface area) have been developed with hundreds of closely spaced channels. These devices may be able to provide electrical microstimulation in the form of biphasic, charge-balanced small amplitude square waves that provide salient, behaviorally relevant information to human subjects. However, there is a lack of knowledge incorporated into their safety and clinical use. Neuromodulation is a field of science, medicine, and bioengineering that encompasses implantable and non-implantable technologies, electrical or chemical, that act upon neural interfaces to improve life for humanity. Our research groups collaboratively investigate neuromodulation performed via electrical microstimulation. Our primary development target is brain neuromodulation. In this article we highlight the application of electrochemistry to the field of neuromodulation.
Collapse
|
8
|
Examining the in vivo functionality of the Magnetically Aligned Regenerative Tissue-Engineered Electronic Nerve Interface (MARTEENI). J Neural Eng 2022; 19. [PMID: 35998559 DOI: 10.1088/1741-2552/ac8bfe] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 08/23/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Although neural-enabled prostheses have been used to restore some lost functionality in clinical trials, they have faced difficulty in achieving high degree of freedom, natural use compared to healthy limbs. This study investigated the in vivo functionality of a flexible and scalable regenerative peripheral-nerve interface suspended within a microchannel-embedded, tissue-engineered hydrogel (the Magnetically Aligned Regenerative Tissue-Engineered Electronic Nerve Interface, MARTEENI) as a potential approach to improving current issues in peripheral nerve interfaces. APPROACH Assembled MARTEENI devices were implanted in the gaps of severed sciatic nerves in Lewis rats. Both acute and chronic electrophysiology were recorded, and channel-isolated activity was examined. In terminal experiments, evoked activity during paw compression and stimulus response curves generated from proximal nerve stimulation were examined. Electrochemical impedance spectroscopy was performed to assess the complex impedance of recording sites during chronic data collection. Features of the foreign-body response in non-functional implants were examined using immunohistological methods. MAIN RESULTS Channel-isolated activity was observed in acute, chronic, and terminal experiments and showed a typically biphasic morphology with peak-to-peak amplitudes varying between 50 to 500 µV. For chronic experiments, electrophysiology was observed for 77 days post-implant. Within the templated hydrogel, regenerating axons formed minifascicles that varied in both size and axon count and were also found to surround device threads. No axons were found to penetrate the foreign-body response. Together these results suggest the MARTEENI is a promising approach for interfacing with peripheral nerves. SIGNIFICANCE Findings demonstrate a high likelihood that observed electrophysiological activity recorded from implanted MARTEENIs originated from neural tissue. The variation in minifascicle size seen histologically suggests that amplitude distributions observed in functional MARTEENIs may be due to a combination of individual axon and mini-compound action potentials. This study provided an assessment of a functional MARTEENI in an in vivo animal model for the first time.
Collapse
|
9
|
The Long-Term Stability of Intracortical Microstimulation and the Foreign Body Response Are Layer Dependent. Front Neurosci 2022; 16:908858. [PMID: 35769707 PMCID: PMC9234554 DOI: 10.3389/fnins.2022.908858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/16/2022] [Indexed: 11/24/2022] Open
Abstract
Intracortical microstimulation (ICMS) of the somatosensory cortex (S1) can restore sensory function in patients with paralysis. Studies assessing the stability of ICMS have reported heterogeneous responses across electrodes and over time, potentially hindering the implementation and translatability of these technologies. The foreign body response (FBR) and the encapsulating glial scar have been associated with a decay in chronic performance of implanted electrodes. Moreover, the morphology, intrinsic properties, and function of cells vary across cortical layers, each potentially affecting the sensitivity to ICMS as well as the degree of the FBR across cortical depth. However, layer-by-layer comparisons of the long-term stability of ICMS as well as the extent of the astrocytic glial scar change across cortical layers have not been well explored. Here, we implanted silicon microelectrodes with electrode sites spanning all the layers of S1 in rats. Using a behavioral paradigm, we obtained ICMS detection thresholds from all cortical layers for up to 40 weeks. Our results showed that the sensitivity and long-term performance of ICMS is indeed layer dependent. Overall, detection thresholds decreased during the first 7 weeks post-implantation (WPI). This was followed by a period in which thresholds remained stable or increased depending on the interfacing layer: thresholds in L1 and L6 exhibited the most consistent increases over time, while those in L4 and L5 remained the most stable. Furthermore, histological investigation of the tissue surrounding the electrode showed a biological response of microglia and macrophages which peaked at L1, while the area of the astrocytic glial scar peaked at L2/3. Interestingly, the biological response of these FBR markers is less exacerbated at L4 and L5, suggesting a potential link between the FBR and the long-term stability of ICMS. These findings suggest that interfacing depth can play an important role in the design of chronically stable implantable microelectrodes.
Collapse
|
10
|
Central and Systemic Effects of Subdiaphragmatic Vagus Nerve Stimulation during the Development of Hypertension in the SHR. FASEB J 2022. [DOI: 10.1096/fasebj.2022.36.s1.r4849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Closed-Loop, Cervical, Epidural Stimulation Elicits Respiratory Neuroplasticity after Spinal Cord Injury in Freely Behaving Rats. eNeuro 2022; 9:ENEURO.0426-21.2021. [PMID: 35058311 PMCID: PMC8856702 DOI: 10.1523/eneuro.0426-21.2021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/08/2021] [Accepted: 12/24/2021] [Indexed: 11/28/2022] Open
Abstract
Over half of all spinal cord injuries (SCIs) are cervical, which can lead to paralysis and respiratory compromise, causing significant morbidity and mortality. Effective treatments to restore breathing after severe upper cervical injury are lacking; thus, it is imperative to develop therapies to address this. Epidural stimulation has successfully restored motor function after SCI for stepping, standing, reaching, grasping, and postural control. We hypothesized that closed-loop stimulation triggered via healthy hemidiaphragm EMG activity has the potential to elicit functional neuroplasticity in spinal respiratory pathways after cervical SCI (cSCI). To test this, we delivered closed-loop, electrical, epidural stimulation (CLES) at the level of the phrenic motor nucleus (C4) for 3 d after C2 hemisection (C2HS) in freely behaving rats. A 2 × 2 Latin Square experimental design incorporated two treatments, C2HS injury and CLES therapy resulting in four groups of adult, female Sprague Dawley rats: C2HS + CLES (n = 8), C2HS (n = 6), intact + CLES (n = 6), intact (n = 6). In stimulated groups, CLES was delivered for 12-20 h/d for 3 d. After C2HS, 3 d of CLES robustly facilitated the slope of stimulus-response curves of ipsilesional spinal motor evoked potentials (sMEPs) versus nonstimulated controls. To our knowledge, this is the first demonstration of CLES eliciting respiratory neuroplasticity after C2HS in freely behaving animals. These findings suggest CLES as a promising future therapy to address respiratory deficiency associated with cSCI.
Collapse
|
12
|
Reducing Behavioral Detection Thresholds per Electrode via Synchronous, Spatially-Dependent Intracortical Microstimulation. Front Neurosci 2022; 16:876142. [PMID: 35784835 PMCID: PMC9247280 DOI: 10.3389/fnins.2022.876142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 05/31/2022] [Indexed: 12/04/2022] Open
Abstract
Intracortical microstimulation (ICMS) has shown promise in restoring quality of life to patients suffering from paralysis, specifically when used in the primary somatosensory cortex (S1). However, these benefits can be hampered by long-term degradation of electrode performance due to the brain's foreign body response. Advances in microfabrication techniques have allowed for the development of neuroprostheses with subcellular electrodes, which are characterized by greater versatility and a less detrimental immune response during chronic use. These probes are hypothesized to enable more selective, higher-resolution stimulation of cortical tissue with long-term implants. However, microstimulation using physiologically relevant charges with these smaller-scale devices can damage electrode sites and reduce the efficacy of the overall device. Studies have shown promise in bypassing this limitation by spreading the stimulation charge between multiple channels in an implanted electrode array, but to our knowledge the usefulness of this strategy in laminar arrays with electrode sites spanning each layer of the cortex remains unexplored. To investigate the efficacy of simultaneous multi-channel ICMS in electrode arrays with stimulation sites spanning cortical depth, we implanted laminar electrode arrays in the primary somatosensory cortex of rats trained in a behavioral avoidance paradigm. By measuring detection thresholds, we were able to quantify improvements in ICMS performance using a simultaneous multi-channel stimulation paradigm. The charge required per site to elicit detection thresholds was halved when stimulating from two adjacent electrode sites, although the overall charge used by the implant was increased. This reduction in threshold charge was more pronounced when stimulating with more than two channels and lessened with greater distance between stimulating channels. Our findings suggest that these improvements are based on the synchronicity and polarity of each stimulus, leading us to conclude that these improvements in stimulation efficiency per electrode are due to charge summation as opposed to a summation of neural responses to stimulation. Additionally, the per-site charge reductions are seen regardless of the cortical depth of each utilized channel. This evocation of physiological detection thresholds with lower stimulation currents per electrode site has implications for the feasibility of stimulation regimes in future advanced neuroprosthetic devices, which could benefit from reducing the charge output per site.
Collapse
|
13
|
Corrigendum: Proceedings of the Eighth Annual Deep Brain Stimulation Think Tank: Advances in Optogenetics, Ethical Issues Affecting DBS Research, Neuromodulatory Approaches for Depression, Adaptive Neurostimulation, and Emerging DBS Technologies. Front Hum Neurosci 2021; 15:765150. [PMID: 34658825 PMCID: PMC8517517 DOI: 10.3389/fnhum.2021.765150] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 09/03/2021] [Indexed: 11/13/2022] Open
|
14
|
The Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation. Front Neurosci 2021; 15:712578. [PMID: 34566563 PMCID: PMC8455844 DOI: 10.3389/fnins.2021.712578] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/19/2021] [Indexed: 11/13/2022] Open
Abstract
Intracortical microelectrodes are neuroprosthetic devices used in brain-machine interfaces to both record and stimulate neural activity in the brain. These technologies have been improved by advances in microfabrication, which have led to the creation of subcellular and high-density microelectrodes. The greater number of independent stimulation channels in these devices allows for improved neuromodulation selectivity, compared to single-site microelectrodes. Elements of electrode design such as electrode-site placement can influence the long-term performance of neuroprostheses. Previous studies have shown that electrode-sites placed on the edge of a planar microelectrode have greater chronic recording functionality than sites placed in the center. However, the effect of electrode-site placement on long-term intracortical microstimulation (ICMS) is still unknown. Here, we show that, in rats chronically implanted with custom-made planar silicon microelectrodes, electrode-sites on the tip of the device outperformed those on both the edge and center in terms of the effect per charge delivered, though there is still a slight advantage to using edge sites over center sites for ICMS. Longitudinal analysis of ICMS detection thresholds over a 16-week period revealed that while all sites followed a similar trend over time, the tip and edge sites consistently elicited the behavioral response with less charge compared to center sites. Furthermore, we quantified channel activity over time and found that edge sites remained more active than center sites over time, though the rate of decay of active sites for center and edge sites was comparable. Our results demonstrate that electrode-site placement plays an important role in the long-term stability of intracortical microstimulation and could be a potential factor to consider in the design of future intracortical electrodes.
Collapse
|
15
|
Engineering the Multi-Enzymatic Activity of Cerium Oxide Nanoparticle Coatings for the Antioxidant Protection of Implants. ADVANCED NANOBIOMED RESEARCH 2021; 1:2100016. [PMID: 34485991 PMCID: PMC8412420 DOI: 10.1002/anbr.202100016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Imbalance of oxidants is a universal contributor to the failure of implanted devices and tissues. A sustained oxidative environment leads to cytotoxicity, prolonged inflammation, and ultimately host rejection of implanted devices/grafts. The incorporation of antioxidant materials can inhibit this redox/inflammatory cycle and enhance implant efficacy. Cerium oxide nanoparticles (CONP) is a highly promising agent that exhibits potent, ubiquitous, and self-renewable antioxidant properties. Integrating CONP as surface coatings provides ease in translating antioxidant properties to various implants/grafts. Herein, we describe the formation of CONP coatings, generated via the sequential deposition of CONP and alginate, and the impact of coating properties, pH, and polymer molecular weight, on their resulting redox profile. Investigation of CONP deposition, layer formation, and coating uniformity/thickness on their resulting oxidant scavenging activity identified key parameters for customizing global antioxidant properties. Results found lower molecular weight alginates and physiological pH shift CONP activity to a higher H2O2 to O2 --scavenging capability. The antioxidant properties measured for these various coatings translated to distinct antioxidant protection to the underlying encapsulated cells. Information gained from this work can be leveraged to tailor coatings towards specific oxidant-scavenging applications and prolong the function of medical devices and cellular implants.
Collapse
|
16
|
Acute vagus nerve stimulation enhances reversal learning in rats. Neurobiol Learn Mem 2021; 184:107498. [PMID: 34332068 DOI: 10.1016/j.nlm.2021.107498] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 07/01/2021] [Accepted: 07/24/2021] [Indexed: 01/19/2023]
Abstract
Cognitive flexibility is a prefrontal cortex-dependent neurocognitive process that enables behavioral adaptation in response to changes in environmental contingencies. Electrical vagus nerve stimulation (VNS) enhances several forms of learning and neuroplasticity, but its effects on cognitive flexibility have not been evaluated. In the current study, a within-subjects design was used to assess the effects of VNS on performance in a novel visual discrimination reversal learning task conducted in touchscreen operant chambers. The task design enabled simultaneous assessment of acute VNS both on reversal learning and on recall of a well-learned discrimination problem. Acute VNS delivered in conjunction with stimuli presentation during reversal learning reliably enhanced learning of new reward contingencies. Enhancement was not observed, however, if VNS was delivered during the session but was not coincident with presentation of to-be-learned stimuli. In addition, whereas VNS delivered at 30 HZ enhanced performance, the same enhancement was not observed using 10 or 50 Hz. Together, these data show that acute VNS facilitates reversal learning and indicate that the timing and frequency of the VNS are critical for these enhancing effects. In separate rats, administration of the norepinephrine reuptake inhibitor atomoxetine also enhanced reversal learning in the same task, consistent with a noradrenergic mechanism through which VNS enhances cognitive flexibility.
Collapse
|
17
|
Electrical epidural stimulation of the cervical spinal cord: implications for spinal respiratory neuroplasticity after spinal cord injury. J Neurophysiol 2021; 126:607-626. [PMID: 34232771 DOI: 10.1152/jn.00625.2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
Traumatic cervical spinal cord injury (cSCI) can lead to damage of bulbospinal pathways to the respiratory motor nuclei and consequent life-threatening respiratory insufficiency due to respiratory muscle paralysis/paresis. Reports of electrical epidural stimulation (EES) of the lumbosacral spinal cord to enable locomotor function after SCI are encouraging, with some evidence of facilitating neural plasticity. Here, we detail the development and success of EES in recovering locomotor function, with consideration of stimulation parameters and safety measures to develop effective EES protocols. EES is just beginning to be applied in other motor, sensory, and autonomic systems; however, there has only been moderate success in preclinical studies aimed at improving breathing function after cSCI. Thus, we explore the rationale for applying EES to the cervical spinal cord, targeting the phrenic motor nucleus for the restoration of breathing. We also suggest cellular/molecular mechanisms by which EES may induce respiratory plasticity, including a brief examination of sex-related differences in these mechanisms. Finally, we suggest that more attention be paid to the effects of specific electrical parameters that have been used in the development of EES protocols and how that can impact the safety and efficacy for those receiving this therapy. Ultimately, we aim to inform readers about the potential benefits of EES in the phrenic motor system and encourage future studies in this area.
Collapse
|
18
|
Proceedings of the Eighth Annual Deep Brain Stimulation Think Tank: Advances in Optogenetics, Ethical Issues Affecting DBS Research, Neuromodulatory Approaches for Depression, Adaptive Neurostimulation, and Emerging DBS Technologies. Front Hum Neurosci 2021; 15:644593. [PMID: 33953663 PMCID: PMC8092047 DOI: 10.3389/fnhum.2021.644593] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 03/10/2021] [Indexed: 12/20/2022] Open
Abstract
We estimate that 208,000 deep brain stimulation (DBS) devices have been implanted to address neurological and neuropsychiatric disorders worldwide. DBS Think Tank presenters pooled data and determined that DBS expanded in its scope and has been applied to multiple brain disorders in an effort to modulate neural circuitry. The DBS Think Tank was founded in 2012 providing a space where clinicians, engineers, researchers from industry and academia discuss current and emerging DBS technologies and logistical and ethical issues facing the field. The emphasis is on cutting edge research and collaboration aimed to advance the DBS field. The Eighth Annual DBS Think Tank was held virtually on September 1 and 2, 2020 (Zoom Video Communications) due to restrictions related to the COVID-19 pandemic. The meeting focused on advances in: (1) optogenetics as a tool for comprehending neurobiology of diseases and on optogenetically-inspired DBS, (2) cutting edge of emerging DBS technologies, (3) ethical issues affecting DBS research and access to care, (4) neuromodulatory approaches for depression, (5) advancing novel hardware, software and imaging methodologies, (6) use of neurophysiological signals in adaptive neurostimulation, and (7) use of more advanced technologies to improve DBS clinical outcomes. There were 178 attendees who participated in a DBS Think Tank survey, which revealed the expansion of DBS into several indications such as obesity, post-traumatic stress disorder, addiction and Alzheimer’s disease. This proceedings summarizes the advances discussed at the Eighth Annual DBS Think Tank.
Collapse
|
19
|
Layer-specific parameters of intracortical microstimulation of the somatosensory cortex. J Neural Eng 2021; 18. [PMID: 33706301 DOI: 10.1088/1741-2552/abedde] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/11/2021] [Indexed: 12/25/2022]
Abstract
Objective. Intracortical microstimulation of the primary somatosensory cortex (S1) has shown great progress in restoring touch sensations to patients with paralysis. Stimulation parameters such as amplitude, phase duration, and frequency can influence the quality of the evoked percept as well as the amount of charge necessary to elicit a response. Previous studies in V1 and auditory cortices have shown that the behavioral responses to stimulation amplitude and phase duration change across cortical depth. However, this depth-dependent response has yet to be investigated in S1. Similarly, to our knowledge, the response to microstimulation frequency across cortical depth remains unexplored.Approach. To assess these questions, we implanted rats in S1 with a microelectrode with electrode-sites spanning all layers of the cortex. A conditioned avoidance behavioral paradigm was used to measure detection thresholds and responses to phase duration and frequency across cortical depth.Main results. Analogous to other cortical areas, the sensitivity to charge and strength-duration chronaxies in S1 varied across cortical layers. Likewise, the sensitivity to microstimulation frequency was layer dependent.Significance. These findings suggest that cortical depth can play an important role in the fine-tuning of stimulation parameters and in the design of intracortical neuroprostheses for clinical applications.
Collapse
|
20
|
Restoration of breathing after opioid overdose and spinal cord injury using temporal interference stimulation. Commun Biol 2021; 4:107. [PMID: 33495588 PMCID: PMC7835220 DOI: 10.1038/s42003-020-01604-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Accepted: 12/14/2020] [Indexed: 01/05/2023] Open
Abstract
Respiratory insufficiency is a leading cause of death due to drug overdose or neuromuscular disease. We hypothesized that a stimulation paradigm using temporal interference (TI) could restore breathing in such conditions. Following opioid overdose in rats, two high frequency (5000 Hz and 5001 Hz), low amplitude waveforms delivered via intramuscular wires in the neck immediately activated the diaphragm and restored ventilation in phase with waveform offset (1 Hz or 60 breaths/min). Following cervical spinal cord injury (SCI), TI stimulation via dorsally placed epidural electrodes uni- or bilaterally activated the diaphragm depending on current and electrode position. In silico modeling indicated that an interferential signal in the ventral spinal cord predicted the evoked response (left versus right diaphragm) and current-ratio-based steering. We conclude that TI stimulation can activate spinal motor neurons after SCI and prevent fatal apnea during drug overdose by restoring ventilation with minimally invasive electrodes.
Collapse
|
21
|
Partial high frequency nerve block decreases neuropathic signaling following chronic sciatic nerve constriction injury. J Neural Eng 2020; 18. [PMID: 33027782 DOI: 10.1088/1741-2552/abbf03] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 10/07/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVE High frequency (HF) block can quickly and reversibly stop nerve conduction. We hypothesized HF block at the sciatic nerve would minimize nociception by preventing neuropathic signals from reaching the central nervous system. APPROACH Lewis rats were implanted with a constriction cuff and a distal cuff electrode around their right sciatic nerve. Tactile sensitivity was evaluated using the 50% paw withdrawal threshold determined using Chaplan's method for von Frey monofilaments. Over the course of 49 days, the 50% paw withdrawal threshold was measured 1) before HF block, 2) during HF block (50 kHz, 3 Vpp), and 3) after HF block. Gait was observed and scored before and during block. At end point, HF block efficacy was directly evaluated using additional cuff electrodes to elicit and record compound neural action potentials across the HF blocking cuff. MAIN RESULTS At days 7 and 14 days post-operation, tactile sensitivity was significantly lower during HF block compared to before and after block (p < 0.005). Additionally, an increase in gait disability was not visually observed during HF block. SIGNIFICANCE HF block can reduce tactile sensitivity in a limb with a neuropthic injury in a rapidly reversible fashion.
Collapse
|
22
|
Second Harmonic Generation Imaging of Collagen in Chronically Implantable Electrodes in Brain Tissue. Front Neurosci 2020; 14:95. [PMID: 32733179 PMCID: PMC7358524 DOI: 10.3389/fnins.2020.00095] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 01/23/2020] [Indexed: 12/15/2022] Open
Abstract
Advances in neural engineering have brought about a number of implantable devices for improved brain stimulation and recording. Unfortunately, many of these micro-implants have not been adopted due to issues of signal loss, deterioration, and host response to the device. While glial scar characterization is critical to better understand the mechanisms that affect device functionality or tissue viability, analysis is frequently hindered by immunohistochemical tissue processing methods that result in device shattering and tissue tearing artifacts. Devices are commonly removed prior to sectioning, which can itself disturb the quality of the study. In this methods implementation study, we use the label free, optical sectioning method of second harmonic generation (SHG) to examine brain slices of various implanted intracortical electrodes and demonstrate collagen fiber distribution not found in normal brain tissue. SHG can easily be used in conjunction with multiphoton microscopy to allow direct intrinsic visualization of collagen-containing glial scars on the surface of cortically implanted electrode probes without imposing the physical strain of tissue sectioning methods required for other high resolution light microscopy modalities. Identification and future measurements of these collagen fibers may be useful in predicting host immune response and device signal fidelity.
Collapse
|
23
|
Designing a bioelectronic treatment for Type 1 diabetes: targeted parasympathetic modulation of insulin secretion. BIOELECTRONICS IN MEDICINE 2020; 3:17-31. [PMID: 33169091 PMCID: PMC7604671 DOI: 10.2217/bem-2020-0006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 06/29/2020] [Indexed: 12/31/2022]
Abstract
The pancreas is a visceral organ with exocrine functions for digestion and endocrine functions for maintenance of blood glucose homeostasis. In pancreatic diseases such as Type 1 diabetes, islets of the endocrine pancreas become dysfunctional and normal regulation of blood glucose concentration ceases. In healthy individuals, parasympathetic signaling to islets via the vagus nerve, triggers release of insulin from pancreatic β-cells and glucagon from α-cells. Using electrical stimulation to augment parasympathetic signaling may provide a way to control pancreatic endocrine functions and ultimately control blood glucose. Historical data suggest that cervical vagus nerve stimulation recruits many visceral organ systems. Simultaneous modulation of liver and digestive function along with pancreatic function provides differential signals that work to both raise and lower blood glucose. Targeted pancreatic vagus nerve stimulation may provide a solution to minimizing off-target effects through careful electrode placement just prior to pancreatic insertion.
Collapse
|
24
|
Targeted Vagus Nerve Stimulation does not Disrupt Cardiac Function in the Diabetic Rat. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6286-6289. [PMID: 31947279 DOI: 10.1109/embc.2019.8857474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In this study, we acutely identified a target branch of the vagus nerve known as the pancreatic branch of the vagus nerve, which exclusively innervates the pancreas by applying electrical stimulus to the known cervical vagus nerve and observing compound neural action potentials at the target nerve. In a set of chronically implanted rats, the target nerve was again cuffed using an electrode and also implanted with a continuous glucose monitor. A model of type 1 diabetes (T1D) was chemically induced and hyperglycemic state confirmed. After induction, stimulation was applied to the pancreatic branch of the vagus nerve and heart rate variability measured to assess the targeted nature of the stimulation. Pancreatic vagus nerve stimulation in a diabetic model was not found to influence heart rate demonstrating the ability of targeted stimulation to be used as for organ-specific neuromodulation while minimizing side effects.
Collapse
|
25
|
Sub‐diaphragmatic vagal nerve stimulation alleviates rodent hypertension associated with gut dysbiosis and reduced serotonergic vagal afferent signaling. FASEB J 2020. [DOI: 10.1096/fasebj.2020.34.s1.06971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
|
27
|
Long Term Closed‐Loop Cervical Epidural Stimulation Elicits Plasticity in Diaphragm Motor Output. FASEB J 2020. [DOI: 10.1096/fasebj.2020.34.s1.07185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Somatosensory Cortex Microstimulation: Behavioral Effects of Phase Duration and Asymmetric Waveforms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1809-1812. [PMID: 31946248 DOI: 10.1109/embc.2019.8856579] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Intracortical microstimulation has proven to be effective in a variety of sensory applications, such as returning touch percepts to paralyzed patients. The parameters of microstimulation play an important role in the perception quality of the stimulus. Eliciting naturalistic percepts is essential for the adaptability and functionality of this technology. Compared to the typical biphasic symmetric waveforms, asymmetric waveforms enhance activation selectivity by preferentially activating cell bodies. Behavioral studies have shown that asymmetric waveforms can elicit behavioral responses, but these require higher charges than typical symmetric waveforms. Here, we investigated the effects of phase duration and waveform asymmetry for somatosensory cortex intracortical microstimulation of freely-behaving rats. Detection thresholds were obtained using a conditioned avoidance behavioral paradigm. Our results indicate that phase duration has significant effects on threshold regardless of symmetry, polarity, and phase order of the waveform. Specifically, shorter phase durations tend to elicit lower behavioral thresholds. Analogous to studies in the auditory cortex, asymmetric waveforms in which the short pulse was cathodic were more effective than those with short-anodic pulses. With short phase durations, these short-cathodic waveforms are capable of evoking behavioral responses at low charges (<; 5 nC/Phase). Altogether, these results suggest the possibility of cell body selective microstimulation at safe thresholds, as well as the potential translatability of neuromodulation parameters across distinct sensory cortical areas.
Collapse
|
29
|
|
30
|
Electrochemical Evaluation of Layer-by-Layer Drug Delivery Coating for Neural Interfaces. ACS APPLIED BIO MATERIALS 2019; 2:5597-5607. [DOI: 10.1021/acsabm.9b00688] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Abstract
OBJECTIVE Recent advances in neural engineering have restored mobility to people with paralysis, relieved symptoms of movement disorders, reduced chronic pain, restored the sense of hearing, and provided sensory perception to individuals with sensory deficits. APPROACH This progress was enabled by the team-based, interdisciplinary approaches used by neural engineers. Neural engineers have advanced clinical frontiers by leveraging tools and discoveries in quantitative and biological sciences and through collaborations between engineering, science, and medicine. The movement toward bioelectronic medicines, where neuromodulation aims to supplement or replace pharmaceuticals to treat chronic medical conditions such as high blood pressure, diabetes and psychiatric disorders is a prime example of a new frontier made possible by neural engineering. Although one of the major goals in neural engineering is to develop technology for clinical applications, this technology may also offer unique opportunities to gain insight into how biological systems operate. MAIN RESULTS Despite significant technological progress, a number of ethical and strategic questions remain unexplored. Addressing these questions will accelerate technology development to address unmet needs. The future of these devices extends far beyond treatment of neurological impairments, including potential human augmentation applications. Our task, as neural engineers, is to push technology forward at the intersection of disciplines, while responsibly considering the readiness to transition this technology outside of the laboratory to consumer products. SIGNIFICANCE This article aims to highlight the current state of the neural engineering field, its links with other engineering and science disciplines, and the challenges and opportunities ahead. The goal of this article is to foster new ideas for innovative applications in neurotechnology.
Collapse
|
32
|
Abstract P188: Electrical Stimulation of Sub-Diaphragmatic Vagal Trunk Alleviates Hypertension in the SHR. Hypertension 2019. [DOI: 10.1161/hyp.74.suppl_1.p188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Introduction:
The vagus facilitates a bidirectional gut-brain communication. Low vagal tone is shown in conditions marked by inflammation and dysbiosis, including hypertension (HTN). However, the role of gut-projecting vagal nerve branches in blood pressure (BP) control is unexplored. Supplementing the potentially impaired gut vagal tone using electrical vagal nerve stimulation (vns) may restore homeostasis of the microbiota-gut-brain axis in HTN.
Methods:
Male 8 week-old Wistar-Kyoto (WKY, N=6) and spontaneously hypertensive rats (SHR, N=10) were used. Rats were implanted with radiotelemetric BP transducers. WKY rats received either a unilateral surgical vagotomy of the ventral sub-diaphragmatic vagal trunk (vgnx, N=3) or sham surgery (SHAM, N=3). SHR were implanted with either a silicone cuff electrode (500μm, Microprobes for Life Sciences, Gaithersburg, MD) (vns, N=5) or a sham cuff (SHAM, N=5) on same vagal trunk. SHR were connected to an IZ2H current controlled stimulus generator (Tucker-Davis Technologies, Alachua, FL), and subjected to biphasic, 600μA, 0.5s/phase, 25Hz vns for 10 minutes per session, three sessions per day, 5 days per week. 24-hour BP recordings were made once per week for seven weeks in all rats. Relative abundance of gut bacterial phyla (
Firmicutes, Bacteriodetes, Actinobacteria
) was determined in fecal DNA of all rats using qPCR.
Results:
Compared with SHAM, WKY vgnx showed a significant elevation in systolic BP (SBP) at week 7 post-vgnx (WKY SHAM: 148±4 mm Hg vs. WKY vgnx: 177±4 mm Hg;
p
<0.05). After 7 weeks of vns, SHR STIM group exhibited a significant dampening in SBP rise from baseline (SHR SHAM: ΔSBP=44±5 mm Hg vs. SHR vns: 22±3 mm Hg;
p
<0.05) and in mean BP (MBP) rise from baseline (SHR SHAM: ΔMBP=38±4 mm Hg vs. SHR vns: 14±3 mm Hg;
p
<0.05) compared to SHAM. No difference was observed in relative abundance of major bacterial phyla between the WKY vgnx and SHR vns rats and their respective controls.
Conclusions:
Bioelectric restoration of gut vagal tone is beneficial in restitution of neural gut-brain axis in control of BP in HTN. Considering no changes were observed in major gut bacterial phyla following WKY vgnx and SHR vns, the observed BP responses may be due to perturbations in gut vagal afferent rather than efferent signaling.
Collapse
|
33
|
Abstract
OBJECTIVE Neuroinflammation has long been associated with the performance decline of intracortical microelectrodes (IMEs). Consequently, several strategies, including the use of anti-inflammatories, have been employed to mitigate the inflammation surrounding IMEs. However, these strategies have had limited success towards achieving a chronically viable cortical neural interface, questioning the efficacy of anti-inflammatory approach. APPROACH Herein, we conducted a systematic study in rats implanted with functional devices by modulating inflammation via systemic injection of lipopolysaccharide (LPS), dexamethasone (DEX), a combination of both, or none to assess the degree of inflammation on device functionality. We hypothesized that implanted rats treated with LPS will have a negative impact, and rats treated with DEX will have a positive impact on functionality IMEs and histological outcome. MAIN RESULTS Contrary to our hypothesis, we did not observe adverse effects in recording metrics among different groups with LPS and/or DEX treatment despite alterations in initial pro-inflammatory markers. We also did not observe any functional benefit of anti-inflammatory treatment. Regardless of the treatment conditions, the recording quality degraded at chronic time points. In end-point histology, implanted rats that received LPS had significantly lower NeuN density and higher levels of CD68 surrounding the implant site, indicative of the pro-inflammatory effect of LPS, which, however, contradicted with the recorded results. SIGNIFICANCE Collectively, our results suggest that acute inflammatory events may not be the key driver for functional degradation of IMEs. Future intervention strategies geared towards improving the functional longevity of intracortical devices may benefit using multi-modal approaches rather than a single approach, such as controlling the initial inflammatory response.
Collapse
|
34
|
In situ electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) for peripheral nerve interfaces. MRS COMMUNICATIONS 2018; 8:1043-1049. [PMID: 34386296 PMCID: PMC8356669 DOI: 10.1557/mrc.2018.138] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 07/12/2018] [Indexed: 06/13/2023]
Abstract
The goal of this study was to perform in situ electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in peripheral nerves to create a soft, precisely located injectable conductive polymer electrode for bi-directional communication. Intraneural PEDOT polymerization was performed to target both outer and inner fascicles via custom fabricated 3D printed cuff electrodes and monomer injection strategies using a combination electrode-cannula system. Electrochemistry, histology, and laser light sheet microscopy revealed the presence of PEDOT at specified locations inside of peripheral nerve. This work demonstrates the potential for using in situ PEDOT electrodeposition as an injectable electrode for recording and stimulation of peripheral nerves.
Collapse
|
35
|
Effect of Asymmetric, Charge Balanced Stimuli on Elicited Compound Neural Action Potentials. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:3370-3373. [PMID: 30441110 DOI: 10.1109/embc.2018.8513057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Whether via cuff or intrafascicular electrode, peripheral neural stimulations often rely on symmetric, charge balanced paradigms. To date, few investigations have been carried out which systematically decompose the features of a stimulus waveform. Factors such as pulse-width, amplitude, and the timing with which they are presented may have significant effects on the quality of the stimuli. This work seeks to fill this gap in knowledge and share insight into how selection of electrical stimuli may affect the resultant neural activation in peripheral nerves. In particular, we found that, although there is some variance, over the parameter range tested there was not a significant effect on neural fiber recruitment percent due to waveform selection.
Collapse
|
36
|
Cervical spinal cord injury in a transgenic mouse expressing fluorophores in neurons, microglia, astrocytes, and oligodendrocytes. FASEB J 2018. [DOI: 10.1096/fasebj.2018.32.1_supplement.625.9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Abstract
Research on neural interfaces has historically concentrated on development of systems for the brain; however, there is increasing interest in peripheral nerve interfaces (PNIs) that could provide benefit when peripheral nerve function is compromised, such as for amputees. Efforts focus on designing scalable and high-performance sensory and motor peripheral nervous system interfaces. Current PNIs face several design challenges such as undersampling of signals from the thousands of axons, nerve-fiber selectivity, and device-tissue integration. To improve PNIs, several researchers have turned to tissue engineering. Peripheral nerve tissue engineering has focused on designing regeneration scaffolds that mimic normal nerve extracellular matrix composition, provide advanced microarchitecture to stimulate cell migration, and have mechanical properties like the native nerve. By combining PNIs with tissue engineering, the goal is to promote natural axon regeneration into the devices to facilitate close contact with electrodes; in contrast, traditional PNIs rely on insertion or placement of electrodes into or around existing nerves, or do not utilize materials to actively facilitate axon regeneration. This review presents the state-of-the-art of PNIs and nerve tissue engineering, highlights recent approaches to combine neural-interface technology and tissue engineering, and addresses the remaining challenges with foreign-body response.
Collapse
|
38
|
Abstract
Using traditional histological methods, researchers are hampered in their ability to image whole tissues or organs in large-scale 3D. Histological sections are generally limited to <20 µm as formalin fixed paraffin section on glass slides or <500 µm for free-floating fixed sections. Therefore, extensive efforts are required for serial sectioning and large-scale image reconstruction methods to recreate 3D for samples >500 µm using traditional methods. In addition, light scatters from macromolecules within tissues, particularly lipids, prevents imaging to a depth >150 µm with most confocal microscopes. To reduce light scatter and to allow for deep tissue imaging using simple confocal microscopy, various optical clearing methods have been developed that are relevant for rodent and human tissue samples fixed by immersion. Several methods are related and use protein crosslinking with acrylamide and tissue clearing with sodium dodecyl sulfate (SDS). Other optical clearing techniques used various solvents though each modification had various advantages and disadvantages. Here, an optimized passive optical clearing method is described for studies of the human pancreas innervation and specifically for interrogation of the innervation of human islets.
Collapse
|
39
|
Electrical Neural Stimulation and Simultaneous in Vivo Monitoring with Transparent Graphene Electrode Arrays Implanted in GCaMP6f Mice. ACS NANO 2018; 12:148-157. [PMID: 29253337 DOI: 10.1021/acsnano.7b04321] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Electrical stimulation using implantable electrodes is widely used to treat various neuronal disorders such as Parkinson's disease and epilepsy and is a widely used research tool in neuroscience studies. However, to date, devices that help better understand the mechanisms of electrical stimulation in neural tissues have been limited to opaque neural electrodes. Imaging spatiotemporal neural responses to electrical stimulation with minimal artifact could allow for various studies that are impossible with existing opaque electrodes. Here, we demonstrate electrical brain stimulation and simultaneous optical monitoring of the underlying neural tissues using carbon-based, fully transparent graphene electrodes implanted in GCaMP6f mice. Fluorescence imaging of neural activity for varying electrical stimulation parameters was conducted with minimal image artifact through transparent graphene electrodes. In addition, full-field imaging of electrical stimulation verified more efficient neural activation with cathode leading stimulation compared to anode leading stimulation. We have characterized the charge density limitation of capacitive four-layer graphene electrodes as 116.07-174.10 μC/cm2 based on electrochemical impedance spectroscopy, cyclic voltammetry, failure bench testing, and in vivo testing. This study demonstrates the transparent ability of graphene neural electrodes and provides a method to further increase understanding and potentially improve therapeutic electrical stimulation in the central and peripheral nervous systems.
Collapse
|
40
|
Foreign Body Response to Intracortical Microelectrodes Is Not Altered with Dip-Coating of Polyethylene Glycol (PEG). Front Neurosci 2017; 11:513. [PMID: 28959183 PMCID: PMC5603673 DOI: 10.3389/fnins.2017.00513] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Accepted: 08/31/2017] [Indexed: 11/24/2022] Open
Abstract
Poly(ethylene glycol) (PEG) is a frequently used polymer for neural implants due to its biocompatible property. As a follow-up to our recent study that used PEG for stiffening flexible neural probes, we have evaluated the biological implications of using devices dip-coated with PEG for chronic neural implants. Mice (wild-type and CX3CR1-GFP) received bilateral implants within the sensorimotor cortex, one hemisphere with a PEG-coated probe and the other with a non-coated probe for 4 weeks. Quantitative analyses were performed using biomarkers for activated microglia/macrophages, astrocytes, blood-brain barrier leakage, and neuronal nuclei to determine the degree of foreign body response (FBR) resulting from the implanted microelectrodes. Despite its well-known acute anti-biofouling property, we observed that PEG-coated devices caused no significantly different FBR compared to non-coated controls at 4 weeks. A repetition using CX3CR1-GFP mice cohort showed similar results. Our histological findings suggest that there is no significant impact of acute delivery of PEG on the FBR in the long-term, and that temporary increase in the device footprint due to the coating of PEG also does not have a significant impact. Large variability seen within the same treatment group also implies that avoiding large superficial vasculature during implantation is not sufficient to minimize inter-animal variability.
Collapse
|
41
|
Placing Sites on the Edge of Planar Silicon Microelectrodes Enhances Chronic Recording Functionality. IEEE Trans Biomed Eng 2017. [PMID: 28641240 DOI: 10.1109/tbme.2017.2715811] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE This study aims to identify the impact of using edge sites over center sites on a planar silicon microelectrode array. METHODS We used custom-designed, silicon-substrate multisite microelectrode arrays with sites on the center, edge, and tip. We compared their single unit recording capability, noise level, impedance, and histology to identify the differences between each site location. Wide and narrow devices were used to evaluate if the differences are consistent and meet theoretical expectations. RESULTS On the wide device, significantly more number of edge sites were functional than center sites over the course of 8 weeks with generally higher signal-to-noise amplitude ratio. On the narrow device, edge sites also performed generally better than center sites, but the differences were not significant and smaller than wide devices. The data from the tip sites were inconclusive. CONCLUSION Edge sites outperformed center sites in terms of single unit recording capability. This benefit decreased as the device gets narrower and the distance to center sites decreases. SIGNIFICANCE We showed that a simple alteration to the site placement can greatly enhance the functionality of silicon microelectrodes. This study promotes the idea that not only the substrate but also the site architecture needs attention to lengthen the lifetime of neural implants.
Collapse
|
42
|
Histological evaluation of flexible neural implants; flexibility limit for reducing the tissue response? J Neural Eng 2017; 14:036026. [PMID: 28470152 DOI: 10.1088/1741-2552/aa68f0] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Flexible neural probes are hypothesized to reduce the chronic foreign body response (FBR) mainly by reducing the strain-stress caused by an interplay between the tethered probe and the brain's micromotion. However, a large discrepancy of Young's modulus still exists (3-6 orders of magnitude) between the flexible probes and the brain tissue. This raises the question of whether we need to bridge this gap; would increasing the probe flexibility proportionally reduce the FBR? APPROACH Using novel off-stoichiometry thiol-enes-epoxy (OSTE+) polymer probes developed in our previous work, we quantitatively evaluated the FBR to four types of probes with different softness: silicon (~150 GPa), polyimide (1.5 GPa), OSTE+Hard (300 MPa), and OSTE+Soft (6 MPa). MAIN RESULTS We observed a significant reduction in the fluorescence intensity of biomarkers for activated microglia/macrophages and blood-brain barrier (BBB) leakiness around the three soft polymer probes compared to the silicon probe, both at 4 weeks and 8 weeks post-implantation. However, we did not observe any consistent differences in the biomarkers among the polymer probes. SIGNIFICANCE The results suggest that the mechanical compliance of neural probes can mediate the degree of FBR, but its impact diminishes after a hypothetical threshold level. This infers that resolving the mechanical mismatch alone has a limited effect on improving the lifetime of neural implants.
Collapse
|
43
|
The effect of multiple thin-film coatings of protein loaded sol-gel on total multi-electrode array thickness. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:129-132. [PMID: 28268296 DOI: 10.1109/embc.2016.7590657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Tetramethyl orthosilicate shows promise as a thin-film delivery vehicle for multi-electrode arrays for drug release and electrical performance; however, its effect upon device footprint has yet to be assessed. Using a previously established silicon wafer chip model, the thickness of one, two, and four protein doped coatings of sol-gel were analyzed via profilometry. Coating thickness was found to be 0.4μm, 1.1μm and 2.2μm on each side of the device. This addition to a native MEA is minimal when compared to other drug delivery paradigms currently associated with neural implants.
Collapse
|
44
|
Proceedings of the Third Annual Deep Brain Stimulation Think Tank: A Review of Emerging Issues and Technologies. Front Neurosci 2016; 10:119. [PMID: 27092042 PMCID: PMC4821860 DOI: 10.3389/fnins.2016.00119] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 03/11/2016] [Indexed: 11/25/2022] Open
Abstract
The proceedings of the 3rd Annual Deep Brain Stimulation Think Tank summarize the most contemporary clinical, electrophysiological, imaging, and computational work on DBS for the treatment of neurological and neuropsychiatric disease. Significant innovations of the past year are emphasized. The Think Tank's contributors represent a unique multidisciplinary ensemble of expert neurologists, neurosurgeons, neuropsychologists, psychiatrists, scientists, engineers, and members of industry. Presentations and discussions covered a broad range of topics, including policy and advocacy considerations for the future of DBS, connectomic approaches to DBS targeting, developments in electrophysiology and related strides toward responsive DBS systems, and recent developments in sensor and device technologies.
Collapse
|
45
|
Abstract
Objective. One approach to conveying sensory feedback in neuroprostheses is to electrically stimulate sensory neurons in the cortex. For this approach to be viable, it is critical that intracortical microstimulation (ICMS) causes minimal damage to the brain. Here, we investigate the effects of chronic ICMS on the neuronal tissue across a variety of stimulation regimes in non-human primates. We also examine each animal’s ability to use their hand—the cortical representation of which is targeted by the ICMS—as a further assay of possible neuronal damage. Approach. We implanted electrode arrays in the primary somatosensory cortex of three Rhesus macaques and delivered ICMS four hours per day, five days per week, for six months. Multiple regimes of ICMS were delivered to investigate the effects of stimulation parameters on the tissue and behavior. Parameters included current amplitude (10–100 μA), pulse train duration (1, 5 s), and duty cycle (1/1, 1/3). We then performed a range of histopathological assays on tissue near the tips of both stimulated and unstimulated electrodes to assess the effects of chronic ICMS on the tissue and their dependence on stimulation parameters. Main results. While the implantation and residence of the arrays in the cortical tissue did cause significant damage, chronic ICMS had no detectable additional effect; furthermore, the animals exhibited no impairments in fine motor control. Significance. Chronic ICMS may be a viable means to convey sensory feedback in neuroprostheses as it does not cause significant damage to the stimulated tissue.
Collapse
|
46
|
The effect of site placement within silicon microelectrodes on the long-term electrophysiological recordings. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:465-8. [PMID: 25569997 DOI: 10.1109/embc.2014.6943629] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Intracortical microelectrodes can be used to treat various neurological disorders given their capabilities to interface with single or multiple populations of neurons. However, most of these penetrating devices have been reported to fail over time, within weeks to months, putatively due to the foreign body response (FBR) which persistently aggravates the surrounding brain tissues. A number of studies have confirmed that various electrode properties, such as size, shape, and surface area, may play a role in the biological responses to the microelectrode. Further experimental data is needed to determine the effect of these properties on the FBR and the recording performance. In this paper, we evaluate the effect of site placement using Michigan arrays with sites on the center, edge, and tip of the shank. The results show that there is significant performance variance between the center, edge, and tip sites.
Collapse
|
47
|
Materials approaches for modulating neural tissue responses to implanted microelectrodes through mechanical and biochemical means. CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE 2014; 18:319-328. [PMID: 25530703 PMCID: PMC4267064 DOI: 10.1016/j.cossms.2014.07.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Implantable intracortical microelectrodes face an uphill struggle for widespread clinical use. Their potential for treating a wide range of traumatic and degenerative neural disease is hampered by their unreliability in chronic settings. A major factor in this decline in chronic performance is a reactive response of brain tissue, which aims to isolate the implanted device from the rest of the healthy tissue. In this review we present a discussion of materials approaches aimed at modulating the reactive tissue response through mechanical and biochemical means. Benefits and challenges associated with these approaches are analyzed, and the importance of multimodal solutions tested in emerging animal models are presented.
Collapse
|
48
|
Glial cells, but not neurons, exhibit a controllable response to a localized inflammatory microenvironment in vitro. FRONTIERS IN NEUROENGINEERING 2014; 7:41. [PMID: 25452724 PMCID: PMC4231942 DOI: 10.3389/fneng.2014.00041] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Accepted: 10/28/2014] [Indexed: 11/13/2022]
Abstract
The ability to design long-lasting intracortical implants hinges on understanding the factors leading to the loss of neuronal density and the formation of the glial scar. In this study, we modify a common in vitro mixed cortical culture model using lipopolysaccharide (LPS) to examine the responses of microglia, astrocytes, and neurons to microwire segments. We also use dip-coated polyethylene glycol (PEG), which we have previously shown can modulate impedance changes to neural microelectrodes, to control the cellular responses. We find that microglia, as expected, exhibit an elevated response to LPS-coated microwire for distances of up to 150 μm, and that this elevated response can be mitigated by co-depositing PEG with LPS. Astrocytes exhibit a more complex, distance-dependent response, whereas neurons do not appear to be affected by the type or magnitude of glial response within this in vitro model. The discrepancy between our in vitro responses and typically observed in vivo responses suggest the importance of using a systems approach to understand the responses of the various brain cell types in a chronic in vivo setting, as well as the necessity of studying the roles of cell types not native to the brain. Our results further indicate that the loss of neuronal density observed in vivo is not a necessary consequence of elevated glial activation.
Collapse
|
49
|
A flexible platform for biofeedback-driven control and personalization of electrical nerve stimulation therapy. IEEE Trans Neural Syst Rehabil Eng 2014; 23:475-84. [PMID: 25167554 DOI: 10.1109/tnsre.2014.2351271] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Electrical vagus nerve stimulation is a treatment alternative for many epileptic and depressed patients whose symptoms are not well managed with pharmaceutical therapy. However, the fixed stimulus, open loop dosing mechanism limits its efficacy and precludes major advances in the quality of therapy. A real-time, responsive form of vagus nerve stimulation is needed to control nerve activation according to therapeutic need. This personalized approach to therapy will improve efficacy and reduce the number and severity of side effects. We present autonomous neural control, a responsive, biofeedback-driven approach that uses the degree of measured nerve activation to control stimulus delivery. We demonstrate autonomous neural control in rats, showing that it rapidly learns how to most efficiently activate any desired proportion of vagal A, B, and/or C fibers over time. This system will maximize efficacy by minimizing patient response variability and by minimizing therapeutic failures resulting from longitudinal decreases in nerve activation with increasing durations of treatment. The value of autonomous neural control equally applies to other applications of electrical nerve stimulation.
Collapse
|
50
|
Resistive and reactive changes to the impedance of intracortical microelectrodes can be mitigated with polyethylene glycol under acute in vitro and in vivo settings. FRONTIERS IN NEUROENGINEERING 2014; 7:33. [PMID: 25136315 PMCID: PMC4120760 DOI: 10.3389/fneng.2014.00033] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 07/11/2014] [Indexed: 01/05/2023]
Abstract
The reactive response of brain tissue to implantable intracortical microelectrodes is thought to negatively affect their recordable signal quality and impedance, resulting in unreliable longitudinal performance. The relationship between the progression of the reactive tissue into a glial scar and the decline in device performance is unclear. We show that exposure to a model protein solution in vitro and acute implantation result in both resistive and capacitive changes to electrode impedance, rather than purely resistive changes. We also show that applying 4000 MW polyethylene glycol (PEG) prevents impedance increases in vitro, and reduces the percent change in impedance in vivo following implantation. Our results highlight the importance of considering the contributions of non-cellular components to the decline in neural microelectrode performance, and present a proof of concept for using a simple dip-coated PEG film to modulate changes in microelectrode impedance.
Collapse
|