1
|
Hemodiafiltration with on-line production of substitution fluid: long-term safety and quantitative assessment of efficacy. CONTRIBUTIONS TO NEPHROLOGY 2015; 108:12-22. [PMID: 8039393 DOI: 10.1159/000423354] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
2
|
Intradialytic glucose infusion increases polysulphone membrane permeability and post-dilutional haemodiafiltration performances. Nephrol Dial Transplant 2000; 15:511-6. [PMID: 10727546 DOI: 10.1093/ndt/15.4.511] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION During real-time monitoring of the ultrafiltration coefficient (Kuf) in haemodiafiltration (HDF), it was noticed that the ultrafiltration performance of polysulphone membrane dialysers increased when hypertonic glucose (D50%) was administered through the venous blood return. METHODS This observation was explored in six non-diabetic chronic dialysis patients during 48 HDF sessions using 1.8 m(2) polysulphone membrane dialysers. In all six patients, 24 sessions were performed with glucose supplementation (as a continuous D50% (500 g/l) infusion at 40 ml/h) and 24 sessions without supplementation. RESULTS Glucose supplementation led to a marked increase in Kuf from 22.8+/-2.2 (without D50%, n=24) to 32. 1+/-3.9 ml/h/mmHg (with D50%, n=24) (P<0.0001). An increase in percentage reduction ratios for urea and creatinine were also consistently observed during the sessions with glucose administration (from respective mean values of 75+/-5 and 68+/-4% to 79+/-4 and 74+/-10%). Mean double-pool Kt/V, calculated from serum urea concentrations, rose from 1.65+/-0.24 (n=24) to 1.86+/-0.24 (n=24) (P<0.005). Similar results were observed in a subgroup of 18 HDF sessions (nine with glucose and nine without) monitored with an on-line urea sensor of spent dialysate. No detrimental effects were induced at any time. CONCLUSIONS We conclude that intravenous glucose administration during high-flux HDF using polysulphone membranes increases significantly both ultrafiltration capacity and dialysis dose delivery.
Collapse
|
3
|
Catabolism in critical illness: estimation from urea nitrogen appearance and creatinine production during continuous renal replacement therapy. Am J Kidney Dis 1998; 32:444-53. [PMID: 9740161 DOI: 10.1053/ajkd.1998.v32.pm9740161] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Thirty-eight intensive care unit (ICU) patients (26 men and 12 women with a mean age of 57.0 +/- 16.6 years) with acute renal failure (ARF) treated by venovenous continuous renal replacement therapy (CRRT) were evaluated while in relatively steady metabolic control. Twenty-seven were undergoing continuous venovenous hemodialysis, nine were undergoing continuous venovenous hemodiafiltration, and two were undergoing continuous venovenous hemofiltration. Periods of analysis varied between 24 and 408 hours (mean duration, 82.7 +/- 70.6 hours; median, 72 hours). Their mean Acute Physiology and Chronic Health Evaluation II (APACHE II) score within 24 hours of admission to the ICU was 21.3 +/- 6.3 and survival rate was 31.6%. Urea nitrogen and creatinine concentrations were determined every 6 to 12 hours in both serum (Cun and Cc, respectively) and effluent (spent dialysate and/or ultrafiltrate). The mean effluent rate was 1,472 +/- 580 mL/h and blood flow rate, 166 +/- 32 mL/min. Urine was collected daily for urea nitrogen and creatinine measurement. Urea nitrogen appearance rate (UnA) and creatinine production rate (Pc), calculated from urea nitrogen (UnMR) and creatinine mass removal (CMR) from both the effluent and the urine, using Garred mass balance equations and the Forbes-Bruining formula, allowed normalized protein catabolic rate (nPCR) and estimates of lean body mass (LBM) to be derived. Creatinine metabolic degradation rate (Dc), estimated by the Mitch formula, was included in the calculation. The lowest body weight recorded during the study period was considered as dry weight (BW). The creatinine index (CI) was also obtained. For each parameter, the results are presented as mean, median, and range values: UnMRe (from effluent), 13.6 +/- 7.2, 12.5, 1.6 to 32.6 mg/min; UnMRu (from urine), 0.13 +/- 0.40, 0, 0 to 2.30 mg/min; UnA, 13.6 +/- 7.0, 12.5, 3.8 to 32.1 mg/min; nPCR, 1.75 +/- 0.82, 1.60, 0.61 to 4.23 g/kg/d; CMRe (from effluent), 942.0 +/- 362.3, 918.0, 211.2 to 1,641.6 mg/d; CMRu (from urine), 44.4 +/- 138.8, 0, 0 to 698.5 mg/d; Dc, 94.6 +/- 49.9, 81.9, 31.0 to 294.1 mg/d; Pc total, 1,067.1 +/- 409.7, 1,053.7, 261.5 to 1,988.2 mg/d; LBM, 38.3 +/- 11.9, 37.9, 15.0 to 65.0 kg; LBM/BW ratio, 49.5% +/- 14.0%, 50.3%, 22.5% to 86.0%; and CI, 13.7 +/- 4.7, 14.2, 4.1 to 25.8 mg/kg/d. When Pc was estimated from the Cockcroft-Gault equations (as Pc'), the mean value for Pc and Pc' was similar (1,067.1 +/- 409.7 v 1,284.9 +/- 484.1 mg/d), but there were relatively large differences for the majority of cases. A positive correlation was observed between UnA and Pc (R = 0.42). Serum albumin and LBM/BW correlated poorly (R = 0.20). Outcome was weakly related to UnA and to nPCR (R = 0.29 and R = 0.31, respectively). Urea nitrogen appearance appears widely variable in critically ill ARF patients. This simple approach can provide useful information for an easy estimate of net protein catabolism in critically ill patients with ARF undergoing CRRT.
Collapse
|
4
|
On-line dialysis quantification in acutely ill patients: preliminary clinical experience with a multipurpose urea sensor monitoring device. ASAIO J 1998; 44:184-90. [PMID: 9617949 DOI: 10.1097/00002480-199805000-00012] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Direct dialysis quantification offers several advantages compared with conventional blood urea kinetic modeling, and monitoring urea concentration in the effluent dialysate with an on-line urea sensor is a practical approach. Such a monitoring device seems desirable in the short-term dialysis setting to optimize and personalize both renal replacement therapy and nutritional support of acutely ill patients. We designed a urea monitoring device consisting of a urea sensor, a multichannel hydraulic circuit, and a PC microcomputer. The sensor determines urea from catalysis of its hydrolysis by urease in liquid solution during neutral conditions. Hydrolysis of urea produces NH4+, and creates an electrical potential difference between two electrodes. Each concentration determination of urea is the average value of 10 measurements; samples are diverted and measured every 7 min. Laboratory calibration of the urea sensor has demonstrated linearity over the range 2-35 mmol/L. Urea monitoring was performed throughout the treatment course, either on the effluent dialysate or ultrafiltrate in seven acutely ill patients treated by either hemofiltration (n=5) or hemodiafiltration (n=2). The slope of the concentration of urea in the effluent over time was used to calculate an index of the dialysis dose delivered (Kt/V), urea mass removal, and protein catabolic rate. In addition, samples of the effluent were drawn every 21 min, and sent to the central laboratory for measurement of urea concentrations using an autoanalyzer. Kt/V values also were calculated with Garred's equation using pre and post session concentrations of urea in blood. Concentrations of urea in the effluent determined by the urea sensor were found to be very close to those obtained from the central laboratory over a wide range of values (3 to 42 mmol/L). In addition, Kt/V values for both hemofiltration and hemodiafiltration, when calculated with concentrations of urea in the effluent obtained by the urea sensor, did not significantly differ from Kt/V values obtained from the laboratory concentrations of urea in the effluent. On-line urea sensor monitoring of the effluent suppresses the cumbersome task of total effluent collection, and the complexity of urea kinetic analysis. The multipurpose prototype described here represents a new, simple, and direct assessment of dialysis dose and protein nutritional status of acutely ill patients, and is suitable for various modalities.
Collapse
|
5
|
Abstract
On-line urea monitoring of the effluent dialysate offers a real-time assessment of dialysis efficiency and metabolic/nutritional characteristics of hemodialysis patients. Quantitative parameters were evaluated by dialysate urea kinetic modeling (DUKM) with an on-line urea sensor in 23 patients treated by high-flux hemodiafiltration (HDF) (215 sessions of 210 to 240 minutes with a mean blood flow rate of 367 +/- 44 mL/min). Overall, the mean effective Kt/V was 1.52 +/- 0.29, the urea mass removed (22.8 +/- 5.5 g/session or 814 +/- 198 mmol/session), the solute removal index (SRI) 73% +/- 6.1%, and the mean normalized protein catabolic rate (nPCR), 1.15 +/- 0.31 g/kg/day. Blood urea kinetic modeling (BUKM), based on pre- and postsession urea concentrations, using equations from Daugirdas and Garred to calculate equilibrated Kt/V and nPCR, respectively, were in good agreement with DUKM, the differences observed appearing not clinically relevant. The variability of evaluated parameters was verified over consecutive sessions for a mean period of 3 weeks in the entire group. Mean variation in Kt/V was 8%; in urea mass removal, 18%; and in nPCR, 18%. When assessed over 1 week in a subgroup of 13 patients, Kt/V and PCR remained relatively stable, and urea mass removal per- and postsession declined from 23.5 +/- 8.0 g (840 +/- 285 mmol) to 18.7 +/- 6.3 g (667 +/- 225 mmol) from the first to the third session of the week, most likely as a consequence of interdialytic intervals. Predialysis urea concentrations followed the same trend. In the current study, DUKM with on-line urea sensor has confirmed that HDF is a highly efficient renal replacement modality; the variability observed in quantitative parameters supports a need for frequent adequacy monitoring. On-line urea monitoring of effluent dialysate is a simple device that provides the opportunity to tailor treatment to patient needs.
Collapse
|
6
|
Direct determination of blood recirculation rate in hemodialysis by a conductivity method. ASAIO J 1998; 44:68-73. [PMID: 9466504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Blood recirculation is one of the key factors of decreasing dialysis efficiency. Determination of recirculation rate (R) is necessary to optimize effective dialysis delivery and to monitor vascular access function. R can be directly measured by a conductivity method in paired filtration dialysis (PFD), a double-compartment hemodiafiltration system that permits direct access to plasma water via the ultrafiltration stream. Measurement of R, in this system, involves the first of two conductivity sensors integrated in a urea monitor (UMS, BelIco-Sorin, Mirandola, Italy), and two saline injections. The rise in conductivity (deltaC1) induced by a 2.7 ml bolus of hypertonic saline 20% (mg/dl) in the arterial line serves for calibration, and is followed by an equivalent injection into the venous line, giving rise to deltaC2. The ratio deltaC2/deltaC1 equals R. A comparison between R values obtained with this method and with the low-flow technique in 31 chronic dialysis patients during 138 PFD sessions is reported. Mean R+/-SD by the conductivity method was 5.1+/-2.0 and 5.7+/-2.0% after 65 and 155 minutes of PFD (correlation coefficient, r = 0.75), whereas it was 6.4+/-4.9% and 5.5+/-4.6% after 30 sec of low blood pump flow for urea and creatinine markers, respectively (r = 0.35). After 120 sec of low flow, mean R increased to 9.0+/-5.1 and 8.8+/-4.6% for urea and creatinine, respectively (r = 0.45). Considerable discrepancies were found in R values measured simultaneously with the two blood markers. Statistically significant differences were found between the two measurement modalities (blood-side and conductivity); the correlation coefficients (r) varied between 0.28 and 0.41. The observed differences in mean R results do not seem considerable from a clinical perspective. The best agreement between blood-side and conductivity R measurements was obtained with Rcreat after 30 sec of low flow. Overall, a wider distribution was found in R values from blood-side determinations, most likely consequent to variability in the dosing method. The conductivity method appears more accurate and simple in assessing total R, and can be readily automated and integrated into the dialysis machine. The authors, therefore, recommend evaluation of R using methods not based on chemical blood concentration values.
Collapse
|
7
|
Protein catabolic rate over lean body mass ratio: a more rational approach to normalize the protein catabolic rate in dialysis patients. Am J Kidney Dis 1997; 30:672-9. [PMID: 9370183 DOI: 10.1016/s0272-6386(97)90492-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Protein catabolic rate (PCR), equivalent to dietary protein intake in "stable" dialysis patients, is widely accepted as a marker of their protein nutritional status. PCR is usually established from urea generation rate using urea kinetic modeling (UKM), but the normalizing factor is still a matter of controversy. By convention, PCR is expressed in grams of protein degraded daily divided by the dry body weight (BW) (nPCRBW). To be valid, this implies that dry BW is close to ideal BW and that body composition is preserved with a lean body mass (LBM) over BW ratio near 0.73. Such conditions being infrequently found in dialysis patients, it has been proposed to normalize PCR to ideal BW or to total body water, but these correction factors are not really appropriate. A more rational approach would be to express PCR as the ratio of protein degraded to the kilograms of LBM (nPCRLBM), thus offering the main advantage of directly coupling PCR to changes in protein or nitrogen reserve. In this study, we developed a combined kinetic model of urea and creatinine applied to the midweek dialysis cycle in 66 end-stage renal disease (ESRD) patients. UKM provided Kt/V and PCR, whereas creatinine kinetic modeling (CKM) was used to calculate LBM. Thirty-four patients with a preserved LBM (LBM/dry BW ratio equal to or greater than 0.70; mean ratio, 0.81 +/- 0.11) and with a dry/ideal BW ratio of 1.01 +/- 0.16 had a mean PCR of 1.14 +/- 0.30 g/kg/24 h when normalized to BW (nPCRBW) and of 1.40 +/- 0.30 g/kg/24 h when normalized to LBM (nPCRLBM). In the 32 patients with a reduced LBM (LBM/dry BW ratio, below 0.70; mean ratio, 0.60 +/- 0.09) and dry/ideal BW ratio of 1.11 +/- 0.23, the mean nPCRBW was 0.99 +/- 0.31 g/kg/24 h, whereas nPCRLBM was 1.62 +/- 0.32 g/kg/24 h. For both subgroups, Kt/V was similar, with mean values of 1.76 +/- 0.34 and 1.69 +/- 0.27. Normalizing PCR to LBM offers a double benefit: it compensates for the error induced by abnormal body composition (eg, obese patients) and permits PCR to be adjusted for the decrease in LBM that occurs with age. We propose nPCRLBM as a more rational index to express PCR in dialysis patients.
Collapse
|
8
|
Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement. Kidney Int 1997; 52:530-7. [PMID: 9264013 DOI: 10.1038/ki.1997.364] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The "gold standard" method to evaluate the mass balances achieved during dialysis for a given solute remains total dialysate collection (TDC). However, since handling over 100 liter volumes is unfeasible in our current dialysis units, alternative methods have been proposed, including urea kinetic modeling, partial dialysate collection (PDC) and more recently, monitoring of dialysate urea by on-line devices. Concerned by the complexity and costs generated by these devices, we aimed to adapt the simple "gold standard" TDC method to clinical practice by diminishing the total volumes to be handled. We describe a new system based on partial dialysate collection, the continuous spent sampling of dialysate (CSSD), and present its technical validation. Further, and for the first time, we report a long-term assessment of dialysis dosage in a dialysis clinic using both the classical PDC and the new CSSD system in a group of six stable dialysis patients who were followed for a period of three years. For the CSSD technique, spent dialysate was continuously sampled by a reversed automatic infusion pump at a rate of 10 ml/hr. The piston was automatically driven by the dialysis machine: switched on when dialysis started, off when dialysis terminated and held during the by pass periods. At the same time the number of production cycles of dialysate was monitored and the total volume of dialysate was calculated by multiplying the volume of the production chamber by the number of cycles. Urea and creatinine concentrations were measured in the syringe and the masses were obtained by multiplying this concentration by the total volume. CSSD and TDC were simultaneously performed in 20 dialysis sessions. The total mass of urea removed was calculated as 58038 and 60442 mmol/session (CSSD and TDC respectively; 3.1 +/- 1.2% variation; r = 0.99; y = 0.92x -28.9; P < 0.001). The total mass of creatinine removed was 146,941,143 and 150,071,195 mumol/session (2.2 +/- 0.9% variation; r = 0.99; y = 0.99x + 263; P < 0.001). To determine the long-term clinical use of PDC and CSSD, all the dialysis sessions monitored during three consecutive summers with PDC (during 1993 and 1994) and with CSSD (1995) in six stable dialysis patients were included. The clinical study comparing PDC and CSSD showed similar urea removal: 510 +/- 59 during the first year with PDC and 516 +/- 46 mmol/dialysis session during the third year, using CSSD. Protein catabolic rate (PCR) could be calculated from total urea removal and was 1.05 +/- 0.11 and 1.05 +/- 0.09 g/kg/day with PDC and CSSD for the same periods. PCR values were clearly more stable when calculated from the daily dialysate collections than when obtained with urea kinetic modeling performed once monthly. We found that CSSD is a simple and accurate method to monitor mass balances of urea or any other solute of clinical interest. With CSSD, dialysis efficacy can be monitored at every dialysis session without the need for bleeding a patient. As it is external to the dialysis machine, it can be attached to any type of machine with a very low cost. The sample of dialysate is easy to handle, since it is already taken in a syringe that is sent directly to the laboratory. The CSSD system is currently in routine use in our unit and has demonstrated its feasibility, low cost and high clinical interest in monitoring dialysis patients.
Collapse
|
9
|
Urea rebound and delivered Kt/V determination with a continuous urea sensor. Nephrol Dial Transplant 1997; 12:535-42. [PMID: 9075137 DOI: 10.1093/ndt/12.3.535] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND The recent introduction of urea sensors for dialysis monitoring has made possible new approaches to urea kinetic modelling. In this study we show how the equilibrated postdialysis urea concentration (Ceq) and Kt/V corrected for double-pool urea kinetics (Kt/Vdp) can be accurately determined using an on-line sensor providing a continuous measure of blood water urea. A modification of the Smye constant volume double-pool theory led to the following equations for Ceq and Kt/Vdp [formula: see text] where Cpre is the blood concentration measured at the start of dialysis, t is the length of the dialysis session (in min) and S(ex) is the constant slope of the blood urea logarithm concentration decline following development of the intercompartmental urea concentration gradient in the first 30-60 min of dialysis. METHODS These equations were tested in 11 patients undergoing 165-240 min of paired filtration dialysis with continuous monitoring of blood urea concentration. Cpre was determined as the plateau concentration during a preliminary period of 15-20 min of slow isolated ultrafiltration. S(ex) was accurately determined from linear regression applied to the urea sensor data from the 80-min point to the end of dialysis. RESULTS Ceq and Kt/Vdp determined from the above equations compared closely to values determined from 25-40 min of urea rebound monitoring with the urea sensor: 10.6 +/- 3.0 versus 10.8 +/- 2.7 mmol/l (mean +/- SD) for Ceq and 1.21 +/- 0.24 versus 1.18 +/- 0.20 for Kt/Vdp, compared to single-pool values of Kt/V = 1.34 +/- 0.23. CONCLUSION This technique may be readily programmed into on-line urea monitors to provide current and extrapolated values of Ceq and Kt/Vdp from about the first hour of dialysis.
Collapse
|
10
|
Equations for the calculation of the protein catabolic rate from predialysis and postdialysis urea concentrations and residual renal clearance in stable hemodialysis patients. Blood Purif 1997; 15:157-68. [PMID: 9262842 DOI: 10.1159/000170327] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Several simple equations exist for the calculation of K1/V from predialysis (Cpre) and postdialysis (Cpost) measurements of urea concentration. Analogous equations are needed for precise determination of patients protein catabolic rate (nPCR) from Cpre and Cpost. In this study we develop three simple nPCR equations from urea mass balance theory. The equations, which include a term for residual function, may be applied to any session of the week for patient dialyzed three times weekly who are in steady state with respect to dialysis dose and protein catabolism. The precision of each equation was tested with Cpre Cpost data obtained from steady state simulations of 540 patients without residual renal clearance (KR) and 972 simulated patients with significant residual KR. The simplest equation has the form: [formula: see text] where V is urea distribution volume and a and d are constants varying with session of the week. When compared to nPCR values calculated from formal urea kinetic modeling, the error determined with this formula never exceeded 5% for the midweek or final session. A more complicated equation of the form: [formula: see text] provided nPCR estimates with a maximum error < 1.3% for any dialysis session of the week and for KR up to 4 ml/min for a 70-kg patient. The only data required for the latter equation are Cpre, Cpost, length of dialysis session, volume ultrafiltered (delta BW), and an approximate value of the patient's urea distribution volume. The proposed equations permit nPCR to be calculated simply and accurately for stable patients dialyzed three times a week.
Collapse
|
11
|
Abstract
The focus of this review article is urea kinetic modeling based on the exploitation of concentration measurements in the spent dialysate stream. After a review of blood-based urea kinetic modeling, dialysate-based techniques are considered, beginning with dialysate collection techniques and their associated urea kinetic modeling equations. Partial dialysate collection methods and equations for the determination of protein catabolic rate based on a 7-day mass balance period are explored next. This is followed by a description of urea sensors and their application for dialysate-based modeling including the determination of protein catabolic rate, predialysis blood urea nitrogen (BUN), and KT/V. How the output of a urea sensor may allow the detection of significant changes in patient clearance during the course of dialysis is illustrated, as well as how double-pool urea kinetics may be accounted for in KT/V determination. Routine determination of patient lean body mass using creatinine kinetic modeling based on partial dialysate collection or a dialysate-based creatinine concentration sensor is demonstrated. Finally, the potential for complete automation of urea kinetic modeling in dialysis machines of the future is explored.
Collapse
|
12
|
Simple equations for protein catabolic rate determination from pre dialysis and post dialysis blood urea nitrogen. ASAIO J 1995; 41:889-95. [PMID: 8589472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Several simple equations exist for Kt/V determination from pre dialysis (Cpre) and post dialysis (Cpost) blood urea. However, comparable equations have not been available for calculation of protein catabolic rate (PCR), an essential parameter for assessing patient status. Three simple formulas for PCR determination were developed from the urea mass balance equation for an anuric patient in protein steady state receiving thrice weekly dialysis. The simplest formula, PCR = 0.0076 [Kt/V] [Cpre + Cpost] + 0.17 relates PCR (in g protein/kg/day) to Kt/V and pre and post dialysis blood urea nitrogen measurements (in mg urea nitrogen/dl) for the midweek session. When tested for 540 simulated patients spanning a range of Kt/V (0.6-1.6); PCR (0.6-1.6 g/kg/day); dialysis duration t (2-4 hrs) and interdialytic weight gain expressed as a percentage of dry body weight gained daily (0-4%), this equation yielded a maximum error of less than +/- 5%, within the accuracy generally required for clinical needs. A more accurate formula, [formula: see text] where Clm is the logarithmic mean of Cpre and Cpost, gave maximum errors in PCR estimation for the same 540 simulated patients of less than +/- 0.6%. Both formulas require a precise value of Kt/V. The equation below incorporates a very accurate simple Kt/V equation recently published by the authors, allowing PCR to be expressed in terms of Cpre, the ratio of Cpost to Cpre (R), the ratio of session ultrafiltration volume (delta BW) to urea distribution volume (V), and dialysis time (t, in min). [formula: see text] This equation was accurate to within a maximum error of +/- 1% for the simulated patient group. These equations allow simple and accurate patient PCR determination, and should be used in conjunction with a simple formula for accurate Kt/V determination to guide end-stage renal failure patient therapy.
Collapse
|
13
|
Abstract
Protein catabolic rate (PCR, in g protein/kg/day) for anuric patients can be accurately determined without blood sampling by equating urea generation over 7 days to the urea dialyzed in the three dialyses of this period as measured by partial dialysate collection (PDC) or with a urea monitor. The feasibility of determining the week's dialyzed urea from measurement of urea dialyzed in a single session, obviating the need to monitor three consecutive dialyses, was examined in a steady-state simulation of 540 anuric patients spanning the full range of dialysis parameters. It was found that the first, midweek, and last dialyses account for nearly constant fractions (37.9, 32.1, and 30.0%, respectively) of the week's urea removal, leading to equations of the form: PCR = CU/BW + 0.17 where U is the grams of urea dialyzed in the first, midweek, or final dialysis of the week, C = 2.45, 2.89, or 3.10, respectively, and BW is the patient's dry weight in kilograms. These equations were tested on 1312 weeks of PDC data gathered in 42 dialysis patients. Using the midweek U resulted in a mean absolute error in PCR < 0.05 g/kg/day when compared to PCR determined using all three of the week's U values.
Collapse
|
14
|
Simple Kt/V formulas based on urea mass balance theory. ASAIO J 1994; 40:997-1004. [PMID: 7858339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
The ratio Kt/V (K is patient clearance, t dialysis time, V urea space) has become the standard measure of dialysis adequacy. In this article simple Kt/V equations are developed theoretically from the urea mass balance equation. Two approximations lead to the most precise equation: [formula: see text] where R is the post to pre dialysis urea ratio, BW/V is the amount of fluid removed during dialysis (delta BW) expressed as a fraction of urea distribution space (V) at dry body weight (BW), and t is dialysis length in hours. A second equation arises with V approximated as 58% of BW. One further approximation leads to a simpler but slightly less precise Kt/V formula: [formula: see text] These and earlier published equations were tested with two sets of data: 1) 49 sessions involving 17 patients on maintenance dialysis and 2) 540 computer simulations spanning all likely values of Kt/V (0.6-1.6), protein catabolic rate (0.6-1.6), interdialytic weight gain (0-4% of BW per day) and dialysis session length (2-4 hr). The most precise formula (upper equation above) had a maximum error of 0.031 and 0.035 Kt/V units for the clinical and simulated data, respectively, whereas the lower equation was slightly less accurate with maximum Kt/V errors of 0.079 and 0.081, respectively. The proposed Kt/V equations are considerably more accurate than previously published formulas.
Collapse
|
15
|
Urea kinetic modeling with a prototype urea sensor in the spent dialysate stream. ASAIO J 1993; 39:M337-41. [PMID: 8268555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
The authors have previously demonstrated the feasibility and accuracy of urea kinetic modeling (UKM) based on monitoring urea concentration in the spent dialysate stream (SDS) throughout the hemodialysis (HD) session. They describe here a prototype urea sensor for this purpose and initial experience with HD patients. The sensor is based on ammonium ion and reference electrodes housed in a cell through which the entire SDS passes. The two electrode tips are bathed in urease solution on one side of a dialysis membrane; the SDS flows along the adjacent side. Urea diffusing across the membrane from the SDS is converted by the urease into ammonium ion, which is measured by the electrode pair. For evaluation, the prototype flowthrough urea sensor was installed in the SDS of a Cobe Centry 3 HD machine for 36 HD sessions. Independent measurement demonstrated a linear relationship between mv output of the sensor and logarithm of SDS urea concentration. The use of SDS urea concentration time profiles obtained with this sensor to obtain accurate values of patient protein catabolic rate (PCR) and KT/V is illustrated. Incorporation of urea sensors such as this prototype into HD machines, will permit complete automation of UKM in the near future.
Collapse
|
16
|
KT/V and protein catabolic rate determination from serial urea measurement in the dialysate effluent stream. Artif Organs 1992; 16:248-55. [PMID: 10078254 DOI: 10.1111/j.1525-1594.1992.tb00305.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A bloodless technique of evaluating protein catabolic rate (PCR) and KT/V (K, clearance; T, dialysis time; V, urea distribution volume) in hemodialysis patients is presented based on serial measurement of urea in the dialysate effluent stream. PCR follows from equating urea generation and urea removal over a 7 day cycle, changes in body stores being comparatively negligible: PCR = 0.026 [U1 + U2 + U3]/BWdry + 0.17, where U1 is the amount of urea in mmol appearing in the dialysate for each session in the 7 day period. KT/V is obtained from the slope of the natural logarithm of spent dialysate urea concentration-time plot: KT/V = [- slope.T + 3.delta BW/BWdry]/[1 - 0.01786.T(hr], where delta BW = amount ultrafiltered in liters. The dialysate-based approach was validated and compared with conventional urea kinetic modeling (UKM) for 17 patients studied for three consecutive dialyses. The dialysate-based and UKM values of PCR agreed well when in vivo clearance values based on total dialysate collection were used for UKM. KT/V values agreed poorly on a session-by-session basis but were nearly equivalent when averaged for the three dialyses of the week. These findings lay the foundation for UKM automation with a urea sensor in the effluent dialysate stream.
Collapse
|
17
|
Reuse of "highly permeable" dialyzers with peroxyacetic acid as sole cleansing and disinfecting agent. ASAIO TRANSACTIONS 1991; 37:653-7. [PMID: 1768505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In the past few years, dialyzer reuse has gained increased clinical acceptance. This has been due both to the availability of automated reconditioning machines and powerful chemical cleaning and disinfecting agents. In this study the authors evaluated the effectiveness of a newly available peroxyacetic acid solution (PAS) (Dialox) as the dual cleaning and disinfecting agent in the reuse of highly permeable dialyzers. An in vivo study was conducted with ten patients already involved in our center's reuse program using the Renatron reprocessing machine and PAS at various dilutions. One hundred forty dialyzers of three different brands and membrane types (HF80 used for hemodiafiltration [HDF], Filtral 16 used for hemodialysis [HD], and FH88 used for hemofiltration [HF]) were employed for a total of 1182 treatments, giving an average 8.4 uses per module. Significantly more uses were obtained with the HF80 and Filtral 16 dialyzers (9.7 and 9.4, respectively) than for the FH88 modules used by the HF patients (6.7 uses per module). Compromised cleaning by backfiltration due to the lack of a second dialysate port on the FH88 may be a possible explanation. Greater membrane plugging due to higher ultrafiltration rates in HF may be another factor. Patient variability was found to be another factor in dialyzer reuse. The cleaning effectiveness of various dilutions of PAS was also tested in this study. The number of uses achieved was not found to vary significantly with PAS strength; however, a greater frequency of second or third reprocessing was required with more dilute cleaning solution. The authors found the dilution achieved on the Renatron reprocessing machine using the currently marketed PAS concentrate to be the most cost effective.
Collapse
|
18
|
Mathematical modeling of erythropoietin therapy. ASAIO TRANSACTIONS 1991; 37:M457-9. [PMID: 1751236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A simple mathematical model to describe hemoglobin (Hb) concentration response to recombinant human erythropoietin (EPO) therapy is proposed. The model is based on the assumption that Hb production increases linearly with EPO dose level. The resulting equation contains two patient parameters: 1) S, the proportionality constant between g Hb generated/L blood/wk and IU EPO administered/kg body weight/wk; and 2) tau, the patient erythrocyte lifetime in weeks. The model was applied retrospectively to 67 patients from the Canadian Erythropoietin Study, yielding an average error of 5.5 g/L between 27 measured and predicted Hb value pairs over the 27 week study. The model parameters, S (mean +/- SD = 0.015 +/- 0.005) and tau (14.0 +/- 4.1), varied over an order of magnitude. The model was also used to predict the EPO dose required to reach a target Hb of 110 g/L; the EPO requirements varied from 55 to 742 IU EPO/kg/wk (mean +/- SD = 225 +/- 124). It is recommended, based upon the model results, that EPO therapy be initiated at 3 IU EPO/kg/wk for each g/L difference between target and baseline Hb, with subsequent EPO dose adjustment guided by patient modeling.
Collapse
|
19
|
Abstract
The effect of reuse on dialyzer efficacy was examined by measuring blood compartment volume and dialyzer mass transfer coefficient (maximum dialyzer clearance) as a function of dialyzer use number. The 102 polysulfone dialyzers tested (F60 and HF80, Fresenius) were reprocessed on Renatron machines using peroxyacetic acid as the dual cleansing and sterilizing agent. Each dialyzer was used an average of 14.4 +/- 5.7SD times and was tested once (twice for 13/102 dialyzers) during a routine dialysis session at an arbitrary use number (7.6 +/- 5.3; range 1 to 24). The parameters tested were found to decrease only marginally with reuse, corresponding to a blood compartment volume loss of approximately 1% (R = 0.04) over a 5-week/15-use period and a decrease in dialyzer mass transfer coefficient of approximately 3% (R = 0.07 and 0.06) over the same period for urea and creatinine, respectively. It was concluded that the loss in dialyzer efficacy is negligible over the average use period of almost 5 weeks per dialyzer.
Collapse
|
20
|
Abstract
It has been shown that the regular administration of erythropoietin (EPO) permits the correction of anemia in end-stage renal failure patients. We analyzed the effect of chronic administration of EPO in 13 stable, regularly dialyzed end-stage renal failure patients over an 18-month period. The effects of EPO were evaluated according to standard criteria including clinical status, blood pressure control, hematology and biochemistry data, protein nutritional status, and dialysis efficiency. Following a 2-week control period, EPO was administered intravenously (IV) after the dialysis session according to a two-phase protocol. The first period (correction phase) consisted of a stepwise EPO dose increment, starting at 3 x 24 IU/kg/wk and doubling the dose every 14 days according to hemoglobin response in order to achieve a target hemoglobin level of approximately 11.0 g/dL (110 g/L). In the second period (maintenance phase) EPO dose was optimized to maintain the hemoglobin level between 100 and 110 g/L (10.0 and 11.0 g/dL), by adjusting either the unit dose or the frequency of injection. Anemia was corrected in all patients within 11 weeks, with EPO dose increasing from 72 to 360 IU/kg/wk. The stabilization of hemoglobin was achieved with an average EPO dose of 275 IU/kg/wk (50 to 476 IU/kg/wk). Concomitantly, a subjective and clinical improvement was noted in all patients. The dialysis efficacy remained in an acceptable range throughout the study, falling significantly (approximately 10%) through the first 3 months of treatment to stabilize at an effective urea clearance of approximately 120 L/wk. The dietary protein intake calculated from urea kinetic modeling ranged between 1.1 and 1.2 g/kg/d.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
21
|
Erythropoietin-induced changes in protein nutrition: quantitative assessment by urea kinetic modeling analysis. Blood Purif 1990; 8:301-8. [PMID: 2091690 DOI: 10.1159/000169982] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
To evaluate objectively the effects of recombinant human erythropoietin (rHuEPO) administration on nutritional status in stable dialyzed patients, we used urea kinetic modeling (UKM) analysis and dietary protein intake evaluation by dietary assessment. Fifteen patients (9 females, 6 males; mean age 46.9 +/- 15.6 years) dialyzed for 9.4 +/- 6.3 years were studied longitudinally for 18 months, consisting of a control period (6 months) and an rHuEPO treatment period (12 months). Treatment modalities based on 3 weekly sessions were hemodialysis in 12 patients (6 cuprophane, 3 cellulose acetate and 3 highly permeable membranes), hemodiafiltration in 2 patients and postdilutional hemofiltration in 1 patient. Bicarbonate buffered dialysate was used in 9 patients and acetate in 6 patients. Urea kinetic modeling using a single-pool model was performed monthly over 1-3 cycles. rHuEPO was administered intravenously at the end of dialysis according to a two-phase protocol: (1) correction of anemia by stepwise increment of rHuEPO dose, and (2) maintenance dose to keep hemoglobin at 10-11 g/dl. rHuEPO administration corrected anemia in all patients, improving their general clinical condition. Dialysis efficacy was significantly reduced (15%) after the 3rd month of rHuEPO therapy. Clearnces were restored by increasing dialysis time and/or improving dialyzer performances, and adequacy of dialysis was maintained in all patients. During the 12 months of rHuEPO therapy, the protein catabolic rate remained stable at 1.2 g/kg/24 h in spite of an increase in appetite. At the same time, dry body weight increased significantly after 9 months, and the ratio dietary protein intake/protein catabolic rate a gross estimation of nitrogen balance, increased.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
22
|
Clinical and microbiological evaluation of a postdilutional hemofiltration system with in-line production of substitution fluid. Blood Purif 1990; 8:160-70. [PMID: 2244993 DOI: 10.1159/000169958] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Safety and efficacy of a recently developed hemofiltration (HF) system with in-line production of substitution fluid (GHS-10; Gambro, Lund, Sweden) based on a sterilizing filtration of acetate buffered dialysate has been evaluated in 4 patients over a 6-month period. Two patients were prematurely excluded from the study: 1 because of acetate intolerance and the other because of kidney transplantation. Two patients completed the study (240 HF sessions). Treatment adequacy was maintained in the 2 medium term treated patients according to the usual clinical and biochemical criteria and a mean exchange volume of 100-105 liters/week (30-35 liters/session three times weekly). Urea kinetic modeling analysis performed over all HF cycles gave the following results: dialysis index (urea clearance.time-on HF/urea volume space) (KT/V) approximately 1-1.1, urea time averaged concentration (UREA TAC) approximately 15-20 mmol/l, and protein catabolic rate (PCR) approximately 1.1-1.2 g/kg/day. Rare clinical adverse symptoms observed during the course of sessions were attributed to acetate intolerance. Microbiological safety was confirmed in vivo by the absence of pyrogenic reactions after 240 HF sessions (approximately 7 m3 substitution fluid infused intravenously) and in vitro by the constant absence of bacteria and/or endotoxin content limulus amaebocyte lysate (LAL) sensibility threshold 10 pg/l within the infusate produced during the sham HF sessions. The fluid mass balance obtained with the GHS-10 monitor was excellent. The electrolyte composition as judged by Na variation remained in a range of 2-3%. GHS-10 used in this study for postdilutional HF confirms that a large quantity of intravenous quality fluid may be safely produced by ultrafiltration from dialysate. It also introduced a new dimension in biocompatibility of dialysis by demonstrating that sterile dialysate may be routinely produced and used for routine dialysis.
Collapse
|
23
|
Urea kinetic modelling by partial dialysate collection. Int J Artif Organs 1989; 12:96-102. [PMID: 2707909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Conventional urea kinetic modelling (UKM) has several drawbacks, in particular the complexity of the required calculations and the need for accurate values of parameters which are difficult to measure, such as dialyzer clearance and blood flow. An alternative method of UKM is proposed based on collecting a small fraction of spent dialysate flow for 3 consecutive dialyses. Application of a urea mass balance to the 7 day period permits neglecting changes in body urea stores. Thus no blood sampling is required for most patients. The required calculations are simple and straightforward. The partial dialysate collection (PDC) method was compared to conventional UKM in a 3 patient, 15 week study. Protein catabolic rate (PCR) from PDC was a smooth curve and consistent with dietary estimation for each patient. Conventional UKM gave variable PCR results which were 17-27% higher on average. This discrepancy was attributed to overestimation of dialyzer clearance. PDC was concluded to be more convenient and accurate than conventional UKM and therefore ideal for routine clinical use.
Collapse
|
24
|
Germicidal effectiveness of Dialox, a new stable peroxyacetic acid solution, in the re-use of high-flux dialysers. Nephrol Dial Transplant 1989; 4:1000-2. [PMID: 2516880 DOI: 10.1093/ndt/4.11.1000] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
In this study we evaluate the effectiveness of a newly available peroxyacetic acid solution (Dialox) as a disinfecting agent in the re-use of highly permeable dialysers. The germicidal properties of Dialox were tested in an in vitro trial on previously used haemodiafilters (HF80, Fresenius) highly contaminated with Pseudomonas aeruginosa, Mycobacterium smegmatis or sporulated Bacillus cereus. Complete freedom from bacterial contamination was observed 5 min after the reprocessing treatment on a Renatron reprocessing machine, using the currently marketed Dialox concentrate.
Collapse
|
25
|
Pump assisted continuous venovenous hemofiltration for treating acute uremia. KIDNEY INTERNATIONAL. SUPPLEMENT 1988; 24:S154-6. [PMID: 3163038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
26
|
A urea kinetic model for haemofiltration. LIFE SUPPORT SYSTEMS : THE JOURNAL OF THE EUROPEAN SOCIETY FOR ARTIFICIAL ORGANS 1985; 3:15-25. [PMID: 3990343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
27
|
Abstract
A wedge cuvette was constructed by fixing 2 glass plates at a known angle with a spacer at one end. This resulted in a thin layer with thickness varying from 0 to 250 micrometer. By measuring the intensity of a beam of light through the thin layer as a function of distance along the wedge (and thus layer thickness), the absorption coefficient at the light wavelength used could be obtained without a separate measurement of I0, the reference light intensity. In addition, the difficult problem of determining accurate layer thickness as encoutered in conventional thin layer photometry has been avoided. Tests of the wedge cuvette method with Evans Blue and Malachite Green serial dilutions as well as with haemoglobin solutions at several oxygen saturations demonstrate that accuracy of the order of 1% can be obtained. Application of the wedge cuvette in experiments on oxygen uptake by layers of haemoglobin solution are discussed.
Collapse
|