1
|
Bustin A, Pineau X, Sridi S, van Heeswijk RB, Jaïs P, Stuber M, Cochet H. Assessment of myocardial injuries in ischaemic and non-ischaemic cardiomyopathies using magnetic resonance T1-rho mapping. Eur Heart J Cardiovasc Imaging 2024; 25:548-557. [PMID: 37987558 DOI: 10.1093/ehjci/jead319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 10/30/2023] [Accepted: 11/16/2023] [Indexed: 11/22/2023] Open
Abstract
AIMS To identify clinical correlates of myocardial T1ρ and to examine how myocardial T1ρ values change under various clinical scenarios. METHODS AND RESULTS A total of 66 patients (26% female, median age 57 years [Q1-Q3, 44-65 years]) with known structural heart disease and 44 controls (50% female, median age 47 years [28-57 years]) underwent cardiac magnetic resonance imaging at 1.5 T, including T1ρ mapping, T2 mapping, native T1 mapping, late gadolinium enhancement, and extracellular volume (ECV) imaging. In controls, T1ρ positively related with T2 (P = 0.038) and increased from basal to apical levels (P < 0.001). As compared with controls and remote myocardium, T1ρ significantly increased in all patients' sub-groups and all types of myocardial injuries: acute and chronic injuries, focal and diffuse tissue abnormalities, as well as ischaemic and non-ischaemic aetiologies (P < 0.05). T1ρ was independently associated with T2 in patients with acute injuries (P = 0.004) and with native T1 and ECV in patients with chronic injuries (P < 0.05). Myocardial T1ρ mapping demonstrated good intra- and inter-observer reproducibility (intraclass correlation coefficient = 0.86 and 0.83, respectively). CONCLUSION Myocardial T1ρ mapping appears to be reproducible and equally sensitive to acute and chronic myocardial injuries, whether of ischaemic or non-ischaemic origins. It may thus be a contrast-agent-free biomarker for gaining new and quantitative insight into myocardial structural disorders. These findings highlight the need for further studies through prospective and randomized trials.
Collapse
Affiliation(s)
- Aurélien Bustin
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604 Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604 Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland
| | - Xavier Pineau
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604 Pessac, France
| | - Soumaya Sridi
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604 Pessac, France
| | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland
| | - Pierre Jaïs
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604 Pessac, France
- Department of Cardiac Electrophysiology, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604 Pessac, France
| | - Matthias Stuber
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604 Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Rue du Bugnon 46, 1011 Lausanne, Switzerland
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604 Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604 Pessac, France
| |
Collapse
|
2
|
Falcão MBL, Mackowiak ALC, Rossi GMC, Prša M, Tenisch E, Rumac S, Bacher M, Rutz T, van Heeswijk RB, Speier P, Markl M, Bastiaansen JAM, Stuber M, Roy CW. Combined free-running four-dimensional anatomical and flow magnetic resonance imaging with native contrast using Synchronization of Neighboring Acquisitions by Physiological Signals. J Cardiovasc Magn Reson 2024; 26:101006. [PMID: 38309581 DOI: 10.1016/j.jocmr.2024.101006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/25/2024] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images. METHODS Thirteen volunteers and two Marfan syndrome patients were scanned without contrast agent using one free-running fast interrupted steady-state (FISS) sequence and one free-running phase-contrast MRI (PC-MRI) sequence. PT signals spanning the two sequences were recorded for retrospective respiratory motion correction and cardiac binning. The magnitude and phase images reconstructed, respectively, from FISS and PC-MRI, were synchronized to create SyNAPS 4D flow datasets. Conventional two-dimensional (2D) flow data were acquired for reference in ascending (AAo) and descending aorta (DAo). The blood-to-myocardium contrast ratio, dynamic vessel area, net volume, and peak flow were used to compare SyNAPS 4D flow with Native 4D flow (without FISS information) and 2D flow. A score of 0-4 was given to each dataset by two blinded experts regarding the feasibility of performing vessel delineation. RESULTS Blood-to-myocardium contrast ratio for SyNAPS 4D flow magnitude images (1.5 ± 0.3) was significantly higher than for Native 4D flow (0.7 ± 0.1, p < 0.01) and was comparable to 2D flow (2.3 ± 0.9, p = 0.02). Image quality scores of SyNAPS 4D flow from the experts (M.P.: 1.9 ± 0.3, E.T.: 2.5 ± 0.5) were overall significantly higher than the scores from Native 4D flow (M.P.: 1.6 ± 0.6, p = 0.03, E.T.: 0.8 ± 0.4, p < 0.01) but still significantly lower than the scores from the reference 2D flow datasets (M.P.: 2.8 ± 0.4, p < 0.01, E.T.: 3.5 ± 0.7, p < 0.01). The Pearson correlation coefficient between the dynamic vessel area measured on SyNAPS 4D flow and that from 2D flow was 0.69 ± 0.24 for the AAo and 0.83 ± 0.10 for the DAo, whereas the Pearson correlation between Native 4D flow and 2D flow measurements was 0.12 ± 0.48 for the AAo and 0.08 ± 0.39 for the DAo. Linear correlations between SyNAPS 4D flow and 2D flow measurements of net volume (r2 = 0.83) and peak flow (r2 = 0.87) were larger than the correlations between Native 4D flow and 2D flow measurements of net volume (r2 = 0.79) and peak flow (r2 = 0.76). CONCLUSION The feasibility and utility of SyNAPS were demonstrated for joint whole-heart anatomical and flow MRI without requiring electrocardiography gating, respiratory navigators, or contrast agents. Using SyNAPS, a high-contrast anatomical imaging sequence can be used to improve 4D flow measurements that often suffer from poor delineation of vessel boundaries in the absence of contrast agents.
Collapse
Affiliation(s)
- Mariana B L Falcão
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Adèle L C Mackowiak
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland; Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Giulia M C Rossi
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Milan Prša
- Woman, Mother, Child Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Estelle Tenisch
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Simone Rumac
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Mario Bacher
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland; Siemens Healthcare GmbH, Erlangen, Germany
| | - Tobias Rutz
- Service of Cardiology, Centre de Resonance Magnétique Cardiaque (CRMC), Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | | | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA; Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA
| | - Jessica A M Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland; Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Christopher W Roy
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
| |
Collapse
|
3
|
Raynaud Q, Di Domenicantonio G, Yerly J, Dardano T, van Heeswijk RB, Lutti A. A characterization of cardiac-induced noise in R 2 * maps of the brain. Magn Reson Med 2024; 91:237-251. [PMID: 37708206 DOI: 10.1002/mrm.29853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 08/11/2023] [Accepted: 08/15/2023] [Indexed: 09/16/2023]
Abstract
PURPOSE Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R2 *. Cardiac-induced noise is challenging to mitigate during the acquisition of R2 * mapping data because its characteristics are unknown. In this work, we aim to characterize cardiac-induced noise in brain maps of the MRI parameter R2 *. METHODS We designed a sampling strategy to acquire multi-echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse-oximeter. We measured the amplitude of cardiac-induced noise in this data and assessed the effect of cardiac pulsation on R2 * maps computed across echoes. The area of k-space that contains most of the cardiac-induced noise in R2 * maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac-induced noise in R2 * maps of the brain. RESULTS In inferior brain regions, cardiac pulsation accounts for R2 * variations of up to 3 s-1 across the cardiac cycle (i.e., ∼35% of the overall variability). Cardiac-induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. A total of 50% to 60% of the overall cardiac-induced noise is localized near the k-space center (k < 0.074 mm-1 ). The tentative cardiac noise mitigation strategy reduced the variability of R2 * maps across repetitions by 11% in the brainstem and 6% across the whole brain. CONCLUSION We provide a characterization of cardiac-induced noise in brain R2 * maps that can be used as a basis for the design of mitigation strategies during data acquisition.
Collapse
Affiliation(s)
- Quentin Raynaud
- Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Giulia Di Domenicantonio
- Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Thomas Dardano
- Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Antoine Lutti
- Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
4
|
van Heeswijk RB, Bauer WR, Bönner F, Janjic JM, Mulder WJM, Schreiber LM, Schwitter J, Flögel U. Cardiovascular Molecular Imaging With Fluorine-19 MRI: The Road to the Clinic. Circ Cardiovasc Imaging 2023; 16:e014742. [PMID: 37725674 DOI: 10.1161/circimaging.123.014742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
Fluorine-19 (19F) magnetic resonance imaging is a unique quantitative molecular imaging modality that makes use of an injectable fluorine-containing tracer that generates the only visible 19F signal in the body. This hot spot imaging technique has recently been used to characterize a wide array of cardiovascular diseases and seen a broad range of technical improvements. Concurrently, its potential to be translated to the clinical setting is being explored. This review provides an overview of this emerging field and demonstrates its diagnostic potential, which shows promise for clinical translation. We will describe 19F magnetic resonance imaging hardware, pulse sequences, and tracers, followed by an overview of cardiovascular applications. Finally, the challenges on the road to clinical translation are discussed.
Collapse
Affiliation(s)
- Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Switzerland (R.B.v.H.)
| | - Wolfgang R Bauer
- Department of Internal Medicine I, Universitätsklinikum Würzburg, Germany (W.R.B.)
| | - Florian Bönner
- Department of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty of Heinrich Heine University, University Hospital Düsseldorf, Germany (F.B.)
| | - Jelena M Janjic
- Graduate School of Pharmaceutical Sciences, School of Pharmacy, Duquesne University, Pittsburgh, PA (J.M.J.)
| | - Willem J M Mulder
- Laboratory of Chemical Biology, Department of Biochemical Engineering, Eindhoven University of Technology, the Netherlands (W.J.M.M.)
- Department of Internal Medicine and Radboud Center for Infectious Diseases, Radboud University Medical Center, Nijmegen, the Netherlands (W.J.M.M.)
| | - Laura M Schreiber
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center (CHFC), Wuerzburg University Hospitals, Germany (L.M.S.)
| | - Juerg Schwitter
- Division of Cardiology, Cardiovascular Department (J.S.), Lausanne University Hospital (CHUV), Switzerland
- CMR Center (J.S.), Lausanne University Hospital (CHUV), Switzerland
- Faculty of Biology and Medicine, University of Lausanne (UNIL), Switzerland (J.S.)
| | - Ulrich Flögel
- Experimental Cardiovascular Imaging (U.F.), Heinrich Heine University, Germany
- Cardiovascular Research Institute Düsseldorf (CARID) (U.F.), Heinrich Heine University, Germany
| |
Collapse
|
5
|
Bustin A, Witschey WRT, van Heeswijk RB, Cochet H, Stuber M. Magnetic resonance myocardial T1ρ mapping : Technical overview, challenges, emerging developments, and clinical applications. J Cardiovasc Magn Reson 2023; 25:34. [PMID: 37331930 DOI: 10.1186/s12968-023-00940-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 05/15/2023] [Indexed: 06/20/2023] Open
Abstract
The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.
Collapse
Affiliation(s)
- Aurelien Bustin
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France.
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | | | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - Matthias Stuber
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|
6
|
Kuhn S, Bustin A, Lamri-Senouci A, Rumac S, Ledoux JB, Colotti R, Bastiaansen JAM, Yerly J, Favre J, Omoumi P, van Heeswijk RB. Improved accuracy and precision of fat-suppressed isotropic 3D T2 mapping MRI of the knee with dictionary fitting and patch-based denoising. Eur Radiol Exp 2023; 7:25. [PMID: 37211577 DOI: 10.1186/s41747-023-00339-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 03/15/2023] [Indexed: 05/23/2023] Open
Abstract
PURPOSE To develop an isotropic three-dimensional (3D) T2 mapping technique for the quantitative assessment of the composition of knee cartilage with high accuracy and precision. METHODS A T2-prepared water-selective isotropic 3D gradient-echo pulse sequence was used to generate four images at 3 T. These were used for three T2 map reconstructions: standard images with an analytical T2 fit (AnT2Fit); standard images with a dictionary-based T2 fit (DictT2Fit); and patch-based-denoised images with a dictionary-based T2 fit (DenDictT2Fit). The accuracy of the three techniques was first optimized in a phantom study against spin-echo imaging, after which knee cartilage T2 values and coefficients of variation (CoV) were assessed in ten subjects in order to establish accuracy and precision in vivo. Data given as mean ± standard deviation. RESULTS After optimization in the phantom, whole-knee cartilage T2 values of the healthy volunteers were 26.6 ± 1.6 ms (AnT2Fit), 42.8 ± 1.8 ms (DictT2Fit, p < 0.001 versus AnT2Fit), and 40.4 ± 1.7 ms (DenDictT2Fit, p = 0.009 versus DictT2Fit). The whole-knee T2 CoV reduced from 51.5% ± 5.6% to 30.5 ± 2.4 and finally to 13.1 ± 1.3%, respectively (p < 0.001 between all). The DictT2Fit improved the data reconstruction time: 48.7 ± 11.3 min (AnT2Fit) versus 7.3 ± 0.7 min (DictT2Fit, p < 0.001). Very small focal lesions were observed in maps generated with DenDictT2Fit. CONCLUSIONS Improved accuracy and precision for isotropic 3D T2 mapping of knee cartilage were demonstrated by using patch-based image denoising and dictionary-based reconstruction. KEY POINTS • Dictionary T2 fitting improves the accuracy of three-dimensional (3D) knee T2 mapping. • Patch-based denoising results in high precision in 3D knee T2 mapping. • Isotropic 3D knee T2 mapping enables the visualization of small anatomical details.
Collapse
Affiliation(s)
- Simon Kuhn
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Aurélien Bustin
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, France
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, INSERM U1045, Centre de Recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
| | - Aicha Lamri-Senouci
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Simone Rumac
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jean-Baptiste Ledoux
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Center for BioMedical Imaging (CIBM), Lausanne, Switzerland
| | - Roberto Colotti
- Biomedical Data Science Center (BDSC), Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Jérôme Yerly
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Center for BioMedical Imaging (CIBM), Lausanne, Switzerland
| | - Julien Favre
- Department of Musculoskeletal Medicine, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Switzerland
| | - Patrick Omoumi
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
| |
Collapse
|
7
|
Franceschiello B, Rumac S, Hilbert T, Nau M, Dziadosz M, Degano G, Roy CW, Gaglianese A, Petri G, Yerly J, Stuber M, Kober T, van Heeswijk RB, Murray MM, Fornari E. Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans. bioRxiv 2023:2023.05.13.540663. [PMID: 37425913 PMCID: PMC10327135 DOI: 10.1101/2023.05.13.540663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/11/2023]
Abstract
Functional magnetic resonance imaging (fMRI) is a methodological cornerstone of neuroscience. Most studies measure blood-oxygen-level-dependent (BOLD) signal using echo-planar imaging (EPI), Cartesian sampling, and image reconstruction with a one-to-one correspondence between the number of acquired volumes and reconstructed images. However, EPI schemes are subject to trade-offs between spatial and temporal resolutions. We overcome these limitations by measuring BOLD with a gradient recalled echo (GRE) with 3D radial-spiral phyllotaxis trajectory at a high sampling rate (28.24ms) on standard 3T field-strength. The framework enables the reconstruction of 3D signal time courses with whole-brain coverage at simultaneously higher spatial (1mm 3 ) and temporal (up to 250ms) resolutions, as compared to optimized EPI schemes. Additionally, artifacts are corrected before image reconstruction; the desired temporal resolution is chosen after scanning and without assumptions on the shape of the hemodynamic response. By showing activation in the calcarine sulcus of 20 participants performing an ON-OFF visual paradigm, we demonstrate the reliability of our method for cognitive neuroscience research.
Collapse
|
8
|
Croci D, Santalla Méndez R, Temme S, Soukup K, Fournier N, Zomer A, Colotti R, Wischnewski V, Flögel U, van Heeswijk RB, Joyce JA. Multispectral fluorine-19 MRI enables longitudinal and noninvasive monitoring of tumor-associated macrophages. Sci Transl Med 2022; 14:eabo2952. [PMID: 36260692 DOI: 10.1126/scitranslmed.abo2952] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
High-grade gliomas, the most common and aggressive primary brain tumors, are characterized by a complex tumor microenvironment (TME). Among the immune cells infiltrating the glioma TME, tumor-associated microglia and macrophages (TAMs) constitute the major compartment. In patients with gliomas, increased TAM abundance is associated with more aggressive disease. Alterations in TAM phenotypes and functions have been reported in preclinical models of multiple cancers during tumor development and after therapeutic interventions, including radiotherapy and molecular targeted therapies. These findings indicate that it is crucial to evaluate TAM abundance and dynamics over time. Current techniques to quantify TAMs in patients rely mainly on histological staining of tumor biopsies. Although informative, these techniques require an invasive procedure to harvest the tissue sample and typically only result in a snapshot of a small region at a single point in time. Fluorine isotope 19 MRI (19F MRI) represents a powerful means to noninvasively and longitudinally monitor myeloid cells in pathological conditions by intravenously injecting perfluorocarbon-containing nanoparticles (PFC-NP). In this study, we demonstrated the feasibility and power of 19F MRI in preclinical models of gliomagenesis, breast-to-brain metastasis, and breast cancer and showed that the major cellular source of 19F signal consists of TAMs. Moreover, multispectral 19F MRI with two different PFC-NP allowed us to identify spatially and temporally distinct TAM niches in radiotherapy-recurrent murine gliomas. Together, we have imaged TAMs noninvasively and longitudinally with integrated cellular, spatial, and temporal resolution, thus revealing important biological insights into the critical functions of TAMs, including in disease recurrence.
Collapse
Affiliation(s)
- Davide Croci
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| | - Rui Santalla Méndez
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| | - Sebastian Temme
- Department of Anesthesiology, Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität, Düsseldorf 40225, Germany.,Experimental Cardiovascular Imaging, Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität, Düsseldorf 40225, Germany
| | - Klara Soukup
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| | - Nadine Fournier
- Agora Cancer Research Center, Lausanne 1011, Switzerland.,Bioinformatics Core Facility, SIB Swiss Institute of Bioinformatics, Lausanne 1011, Switzerland
| | - Anoek Zomer
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| | - Roberto Colotti
- In Vivo Imaging Facility (IVIF), Department of Research and Training, Lausanne University Hospital and University of Lausanne, Lausanne 1011, Switzerland
| | - Vladimir Wischnewski
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| | - Ulrich Flögel
- Experimental Cardiovascular Imaging, Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität, Düsseldorf 40225, Germany.,Institute for Molecular Cardiology, Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität Düsseldorf, Düsseldorf 40225, Germany
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne 1011, Switzerland
| | - Johanna A Joyce
- Department of Oncology, University of Lausanne, Lausanne 1011, Switzerland.,Ludwig Institute for Cancer Research, University of Lausanne, Lausanne 1011, Switzerland.,Agora Cancer Research Center, Lausanne 1011, Switzerland
| |
Collapse
|
9
|
Ogier AC, Bustin A, Cochet H, Schwitter J, van Heeswijk RB. The Road Toward Reproducibility of Parametric Mapping of the Heart: A Technical Review. Front Cardiovasc Med 2022; 9:876475. [PMID: 35600490 PMCID: PMC9120534 DOI: 10.3389/fcvm.2022.876475] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 04/11/2022] [Indexed: 01/02/2023] Open
Abstract
Parametric mapping of the heart has become an essential part of many cardiovascular magnetic resonance imaging exams, and is used for tissue characterization and diagnosis in a broad range of cardiovascular diseases. These pulse sequences are used to quantify the myocardial T1, T2, T2*, and T1ρ relaxation times, which are unique surrogate indices of fibrosis, edema and iron deposition that can be used to monitor a disease over time or to compare patients to one another. Parametric mapping is now well-accepted in the clinical setting, but its wider dissemination is hindered by limited inter-center reproducibility and relatively long acquisition times. Recently, several new parametric mapping techniques have appeared that address both of these problems, but substantial hurdles remain for widespread clinical adoption. This review serves both as a primer for newcomers to the field of parametric mapping and as a technical update for those already well at home in it. It aims to establish what is currently needed to improve the reproducibility of parametric mapping of the heart. To this end, we first give an overview of the metrics by which a mapping technique can be assessed, such as bias and variability, as well as the basic physics behind the relaxation times themselves and what their relevance is in the prospect of myocardial tissue characterization. This is followed by a summary of routine mapping techniques and their variations. The problems in reproducibility and the sources of bias and variability of these techniques are reviewed. Subsequently, novel fast, whole-heart, and multi-parametric techniques and their merits are treated in the light of their reproducibility. This includes state of the art segmentation techniques applied to parametric maps, and how artificial intelligence is being harnessed to solve this long-standing conundrum. We finish up by sketching an outlook on the road toward inter-center reproducibility, and what to expect in the future.
Collapse
Affiliation(s)
- Augustin C. Ogier
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
| | - Aurelien Bustin
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, Pessac, France
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, Pessac, France
| | - Juerg Schwitter
- Cardiac MR Center, Cardiology Service, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
- *Correspondence: Ruud B. van Heeswijk
| |
Collapse
|
10
|
Uretsky S, Aggarwal N, van Heeswijk RB, Rajpal S, Rowin E, Taylor MD, Verjans JW, Wokhlu A, Markl M, Raman SV, Shah DJ. Standards for writing Society for Cardiovascular Magnetic Resonance (SCMR) endorsed guidelines, expert consensus, and recommendations: a report of the publications committee. J Cardiovasc Magn Reson 2021; 23:129. [PMID: 34732221 PMCID: PMC8567541 DOI: 10.1186/s12968-021-00801-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 07/28/2021] [Indexed: 11/10/2022] Open
Affiliation(s)
- Seth Uretsky
- Department of Cardiovascular Medicine, Gagnon Cardiovascular Institute, Morristown Medical Center/Atlantic Health System, Morristown, NJ, USA.
| | | | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Saurabh Rajpal
- Division of Cardiology, Department of Internal Medicine, The Ohio State University, Columbus, OH, USA
| | - Ethan Rowin
- CardioVascular Center, Tufts Medical Center, Boston, MA, USA
| | - Michael D Taylor
- Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Johan W Verjans
- Royal Adelaide Hospital, University of Adelaide, Adelaide, Australia
| | - Anita Wokhlu
- Department of Medicine, Division of Cardiology, University of Florida, Gainesville, FL, USA
| | - Michael Markl
- Departments of Radiology and Biomedical Engineering, Northwestern University, Feinberg School of Medicine and McCormick School of Engineering, Evanston, USA
| | - Subha V Raman
- Indiana University and IU Health, Indianapolis, IN, USA
| | - Dipan J Shah
- Houston Methodist DeBakey Heart and Vascular Center, Houston, TX, USA
| |
Collapse
|
11
|
Dorniak K, Di Sopra L, Sabisz A, Glinska A, Roy CW, Gorczewski K, Piccini D, Yerly J, Jankowska H, Fijałkowska J, Szurowska E, Stuber M, van Heeswijk RB. Respiratory Motion-Registered Isotropic Whole-Heart T 2 Mapping in Patients With Acute Non-ischemic Myocardial Injury. Front Cardiovasc Med 2021; 8:712383. [PMID: 34660714 PMCID: PMC8511642 DOI: 10.3389/fcvm.2021.712383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 09/06/2021] [Indexed: 11/13/2022] Open
Abstract
Background: T2 mapping is a magnetic resonance imaging technique that can be used to detect myocardial edema and inflammation. However, the focal nature of myocardial inflammation may render conventional 2D approaches suboptimal and make whole-heart isotropic 3D mapping desirable. While self-navigated 3D radial T2 mapping has been demonstrated to work well at a magnetic field strength of 3T, it results in too noisy maps at 1.5T. We therefore implemented a novel respiratory motion-resolved compressed-sensing reconstruction in order to improve the 3D T2 mapping precision and accuracy at 1.5T, and tested this in a heterogeneous patient cohort. Materials and Methods: Nine healthy volunteers and 25 consecutive patients with suspected acute non-ischemic myocardial injury (sarcoidosis, n = 19; systemic sclerosis, n = 2; acute graft rejection, n = 2, and myocarditis, n = 2) were included. The free-breathing T2 maps were acquired as three ECG-triggered T2-prepared 3D radial volumes. A respiratory motion-resolved reconstruction was followed by image registration of the respiratory states and pixel-wise T2 mapping. The resulting 3D maps were compared to routine 2D T2 maps. The T2 values of segments with and without late gadolinium enhancement (LGE) were compared in patients. Results: In the healthy volunteers, the myocardial T2 values obtained with the 2D and 3D techniques were similar (45.8 ± 1.8 vs. 46.8 ± 2.9 ms, respectively; P = 0.33). Conversely, in patients, T2 values did differ between 2D (46.7 ± 3.6 ms) and 3D techniques (50.1 ± 4.2 ms, P = 0.004). Moreover, with the 2D technique, T2 values of the LGE-positive segments were similar to those of the LGE-negative segments (T2LGE-= 46.2 ± 3.7 vs. T2LGE+ = 47.6 ± 4.1 ms; P = 0.49), whereas the 3D technique did show a significant difference (T2LGE- = 49.3 ± 6.7 vs. T2LGE+ = 52.6 ± 8.7 ms, P = 0.006). Conclusion: Respiratory motion-registered 3D radial imaging at 1.5T led to accurate isotropic 3D whole-heart T2 maps, both in the healthy volunteers and in a small patient cohort with suspected non-ischemic myocardial injury. Significantly higher T2 values were found in patients as compared to controls in 3D but not in 2D, suggestive of the technique's potential to increase the sensitivity of CMR at earlier stages of disease. Further study will be needed to demonstrate its accuracy.
Collapse
Affiliation(s)
- Karolina Dorniak
- Department of Noninvasive Cardiac Diagnostics, Medical University of Gdansk, Gdansk, Poland
| | - Lorenzo Di Sopra
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Agnieszka Sabisz
- Second Department of Radiology, Medical University of Gdansk, Gdansk, Poland
| | - Anna Glinska
- Second Department of Radiology, Medical University of Gdansk, Gdansk, Poland
| | - Christopher W Roy
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | | | - Davide Piccini
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Hanna Jankowska
- Department of Noninvasive Cardiac Diagnostics, Medical University of Gdansk, Gdansk, Poland
| | - Jadwiga Fijałkowska
- Second Department of Radiology, Medical University of Gdansk, Gdansk, Poland
| | - Edyta Szurowska
- Second Department of Radiology, Medical University of Gdansk, Gdansk, Poland
| | - Matthias Stuber
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
12
|
Arn L, van Heeswijk RB, Stuber M, Bastiaansen JAM. A robust broadband fat-suppressing phaser T 2 -preparation module for cardiac magnetic resonance imaging at 3T. Magn Reson Med 2021; 86:1434-1444. [PMID: 33759208 DOI: 10.1002/mrm.28785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 03/01/2021] [Accepted: 03/04/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE Designing a new T2 -preparation (T2 -Prep) module to simultaneously provide robust fat suppression and efficient T2 preparation without requiring an additional fat-suppression module for T2 -weighted imaging at 3T. METHODS The tip-down radiofrequency (RF) pulse of an adiabatic T2 -Prep module was replaced by a custom-designed RF-excitation pulse that induces a phase difference between water and fat, resulting in a simultaneous T2 preparation of water signals and the suppression of fat signals at the end of the module (a phaser adiabatic T2 -Prep). Numerical simulations and in vitro and in vivo electrocardiogram (ECG)-triggered navigator-gated acquisitions of the human heart were performed. Blood, myocardium, and fat signal-to-noise ratios and right coronary artery vessel sharpness were compared against previously published adiabatic T2 -Prep approaches. RESULTS Numerical simulations predicted an increased fat-suppression bandwidth and decreased sensitivity to transmit magnetic field inhomogeneities using the proposed approach while preserving the water T2 -Prep capabilities. This was confirmed by the tissue signals acquired in the phantom and the in vivo images, which show similar blood and myocardium signal-to-noise ratio, contrast-to-noise ratio, and significantly reduced fat signal-to-noise ratio compared with the other methods. As a result, the right coronary artery conspicuity was significantly increased. CONCLUSION A novel fat-suppressing T2 -Prep method was developed and implemented that showed robust fat suppression and increased vessel sharpness compared with conventional techniques while preserving its T2 -Prep capabilities.
Collapse
Affiliation(s)
- Lionel Arn
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,Center for Biomedical Imaging, Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
13
|
Dorniak K, Stopczyńska I, van Heeswijk RB, Żaczyńska-Buchowiecka M, Fijałkowska J, Glińska A, Gruchała M, Szurowska E, Dudziak M, Sabisz A. Cardiac magnetic resonance imaging with T2 mapping for the monitoring of acute heart transplant rejection in patients with problematic endomyocardial biopsy: in anticipation of new recommendations. Kardiol Pol 2021; 79:339-343. [PMID: 33687863 DOI: 10.33963/kp.15852] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Bernabei I, Sayous Y, Raja AY, Amma MR, Viry A, Steinmetz S, Falgayrac G, van Heeswijk RB, Omoumi P, Pascart T, Stamp LK, Nasi S, Hügle T, Busso N, So AK, Becce F. Multi-energy photon-counting computed tomography versus other clinical imaging techniques for the identification of articular calcium crystal deposition. Rheumatology (Oxford) 2021; 60:2483-2485. [DOI: 10.1093/rheumatology/keab125] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 01/23/2021] [Indexed: 12/17/2022] Open
Affiliation(s)
- Ilaria Bernabei
- Department of Rheumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Yann Sayous
- Department of Physics and Astronomy, University of Canterbury
| | - Aamir Y Raja
- Department of Radiology, University of Otago, Christchurch, New Zealand
- Department of Physics, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Maya R Amma
- Department of Radiology, University of Otago, Christchurch, New Zealand
| | | | - Sylvain Steinmetz
- Department of Orthopaedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Guillaume Falgayrac
- Marrow Adiposity and Bone Laboratory (MABLab), UR 4490, University of Lille, Lille, France
| | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Patrick Omoumi
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Tristan Pascart
- Marrow Adiposity and Bone Laboratory (MABLab), UR 4490, University of Lille, Lille, France
- Department of Rheumatology, Lille Catholic University Hospitals, University of Lille, Lille, France
| | - Lisa K Stamp
- Department of Medicine, University of Otago, Christchurch, New Zealand
| | - Sonia Nasi
- Department of Rheumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Thomas Hügle
- Department of Rheumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Nathalie Busso
- Department of Rheumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alexander K So
- Department of Rheumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | | |
Collapse
|
15
|
Darçot E, Yerly J, Hilbert T, Colotti R, Najdenovska E, Kober T, Stuber M, van Heeswijk RB. Compressed sensing with signal averaging for improved sensitivity and motion artifact reduction in fluorine-19 MRI. NMR Biomed 2021; 34:e4418. [PMID: 33002268 DOI: 10.1002/nbm.4418] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 09/09/2020] [Accepted: 09/11/2020] [Indexed: 06/11/2023]
Abstract
Fluorine-19 (19 F) MRI of injected perfluorocarbon emulsions (PFCs) allows for the non-invasive quantification of inflammation and cell tracking, but suffers from a low signal-to-noise ratio and extended scan time. To address this limitation, we tested the hypotheses that a 19 F MRI pulse sequence that combines a specific undersampling regime with signal averaging has both increased sensitivity and robustness against motion artifacts compared with a non-averaged fully sampled pulse sequence, when both datasets are reconstructed with compressed sensing. As a proof of principle, numerical simulations and phantom experiments were performed on selected variable ranges to characterize the point spread function of undersampling patterns, as well as the vulnerability to noise of undersampling and reconstruction parameters with paired numbers of x signal averages and acceleration factor x (NAx-AFx). The numerical simulations demonstrated that a probability density function that uses 25% of the samples to fully sample the k-space central area allowed for an optimal balance between limited blurring and artifact incoherence. At all investigated noise levels, the Dice similarity coefficient (DSC) strongly depended on the regularization parameters and acceleration factor. In phantoms, the motion robustness of an NA8-AF8 undersampling pattern versus NA1-AF1 was evaluated with simulated and real motion patterns. Differences were assessed with the DSC, which was consistently higher for the NA8-AF8 compared with the NA1-AF1 strategy, for both simulated and real cyclic motion patterns (P < 0.001). Both strategies were validated in vivo in mice (n = 2) injected with perfluoropolyether. Here, the images displayed a sharper delineation of the liver with the NA8-AF8 strategy than with the NA1-AF1 strategy. In conclusion, we validated the hypotheses that in 19 F MRI the combination of undersampling and averaging improves both the sensitivity and the robustness against motion artifacts.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Lausanne and Geneva, Switzerland
| | - Tom Hilbert
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Advanced Clinical Imaging Technology (HC CMEA SUI DI PI), Siemens Healthcare AG, Lausanne, Switzerland
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Roberto Colotti
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Elena Najdenovska
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Lausanne and Geneva, Switzerland
| | - Tobias Kober
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Advanced Clinical Imaging Technology (HC CMEA SUI DI PI), Siemens Healthcare AG, Lausanne, Switzerland
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Matthias Stuber
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Lausanne and Geneva, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Lausanne and Geneva, Switzerland
| |
Collapse
|
16
|
Darçot E, Colotti R, Brennan D, Deuchar GA, Santosh C, van Heeswijk RB. A characterization of ABL-101 as a potential tracer for clinical fluorine-19 MRI. NMR Biomed 2020; 33:e4212. [PMID: 31724252 DOI: 10.1002/nbm.4212] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 10/10/2019] [Accepted: 10/18/2019] [Indexed: 06/10/2023]
Abstract
The two main challenges that prevent the translation of fluorine-19 (19 F) MRI for inflammation monitoring or cell tracking into clinical practice are (i) the relatively low signal-to-noise ratio generated by the injected perfluorocarbon (PFC), which necessitates long scan times, and (ii) the need for regulatory approval and a high biocompatibility of PFCs that are also suitable for MRI. ABL-101, an emulsion of perfluoro(t-butylcyclohexane), is a third-generation PFC that is already used in clinical trials, but has not yet been used for 19 F MRI. The objective of this study was therefore to assess the performance of ABL-101 as a 19 F MRI tracer. At magnetic field strengths of 3, 9.4 and 14.1 T, the CF3 groups of ABL-101 generated a large well-separated singlet with T2 /T1 ratios of >0.27, >0.14 and > 0.05, respectively. All relaxation times decreased with the increase in magnetic field strength. The detection limit of ABL-101 in a 0.25 mm3 voxel at 3 T, 37°C and with a 3-minute acquisition time was 7.21mM. After intravenous injection, the clearance half-lives of the ABL-101 19 F MR signal in mouse (n = 3) spleen and liver were 6.85 ± 0.45 and 3.20 ± 0.35 days, respectively. These results demonstrate that ABL-101 has 19 F MR characteristics that are similar to those of PFCs developed specifically for MRI, while it has clearance half-lives similar to PFCs that have previously been used in large doses in non-MRI clinical trials. Overall, ABL-101 is thus a very promising candidate tracer for future clinical trials that use 19 F MRI for cell tracking or the monitoring of inflammation.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Roberto Colotti
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - David Brennan
- Department of Neuroradiology, Institute of Neurological Sciences, Queen Elizabeth University Hospital, Glasgow, UK
- Aurum Biosciences Ltd, Glasgow, UK
| | | | - Celestine Santosh
- Department of Neuroradiology, Institute of Neurological Sciences, Queen Elizabeth University Hospital, Glasgow, UK
- Aurum Biosciences Ltd, Glasgow, UK
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne and Geneva, Switzerland
| |
Collapse
|
17
|
Darçot E, Colotti R, Pellegrin M, Wilson A, Siegert S, Bouzourene K, Yerly J, Mazzolai L, Stuber M, van Heeswijk RB. Towards Quantification of Inflammation in Atherosclerotic Plaque in the Clinic - Characterization and Optimization of Fluorine-19 MRI in Mice at 3 T. Sci Rep 2019; 9:17488. [PMID: 31767900 PMCID: PMC6877590 DOI: 10.1038/s41598-019-53905-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 11/07/2019] [Indexed: 12/14/2022] Open
Abstract
Fluorine-19 (19F) magnetic resonance imaging (MRI) of injected perfluorocarbons (PFCs) can be used for the quantification and monitoring of inflammation in diseases such as atherosclerosis. To advance the translation of this technique to the clinical setting, we aimed to 1) demonstrate the feasibility of quantitative 19F MRI in small inflammation foci on a clinical scanner, and 2) to characterize the PFC-incorporating leukocyte populations and plaques. To this end, thirteen atherosclerotic apolipoprotein-E-knockout mice received 2 × 200 µL PFC, and were scanned on a 3 T clinical MR system. 19F MR signal was detected in the aortic arch and its branches in all mice, with a signal-to-noise ratio of 11.1 (interquartile range IQR = 9.5–13.1) and a PFC concentration of 1.15 mM (IQR = 0.79–1.28). Imaging flow cytometry was used on another ten animals and indicated that PFC-labeled leukocytes in the aortic arch and it branches were mainly dendritic cells, macrophages and neutrophils (ratio 9:1:1). Finally, immunohistochemistry analysis confirmed the presence of those cells in the plaques. We thus successfully used 19F MRI for the noninvasive quantification of PFC in atherosclerotic plaque in mice on a clinical scanner, demonstrating the feasibility of detecting very small inflammation foci at 3 T, and advancing the translation of 19F MRI to the human setting.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Roberto Colotti
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Maxime Pellegrin
- Division of Angiology, Heart and Vessel Department, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Anne Wilson
- Flow Cytometry Facility, Department of Formation and Research, University of Lausanne (UNIL), Epalinges, Switzerland
| | - Stefanie Siegert
- Flow Cytometry Facility, Department of Formation and Research, University of Lausanne (UNIL), Epalinges, Switzerland
| | - Karima Bouzourene
- Division of Angiology, Heart and Vessel Department, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne and Geneva, Switzerland
| | - Lucia Mazzolai
- Division of Angiology, Heart and Vessel Department, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Matthias Stuber
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne and Geneva, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
| |
Collapse
|
18
|
van Heeswijk RB, Bastiaansen JAM, Iglesias JF, Degrauwe S, Rotman S, Barras JL, Regamey J, Lauriers N, Tozzi P, Yerly J, Ginami G, Stuber M, Hullin R. Quantification of myocardial interstitial fibrosis and extracellular volume for the detection of cardiac allograft vasculopathy. Int J Cardiovasc Imaging 2019; 36:533-542. [DOI: 10.1007/s10554-019-01733-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 11/09/2019] [Indexed: 01/06/2023]
|
19
|
Bastiaansen JAM, van Heeswijk RB, Stuber M, Piccini D. Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE). J Cardiovasc Magn Reson 2019; 21:38. [PMID: 31291957 PMCID: PMC6621993 DOI: 10.1186/s12968-019-0543-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 05/20/2019] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Robust and homogeneous lipid suppression is mandatory for coronary artery cardiovascular magnetic resonance (CMR) imaging since the coronary arteries are commonly embedded in epicardial fat. However, effective large volume lipid suppression becomes more challenging when performing radial whole-heart coronary artery CMR for respiratory self-navigation and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression not only hinders a correct visualization of the coronary vessels and generates image artifacts, but may also affect advanced motion correction methods. The aim of this study was to evaluate a recently reported lipid insensitive CMR method when applied to a noncontrast self-navigated coronary artery CMR acquisitions at 3 T, and to compare it to more conventional fat suppression techniques. METHODS Lipid insensitive binomial off resonant excitation (LIBRE) radiofrequency excitation pulses were included into a self-navigated 3D radial GRE coronary artery CMR sequence at 3 T. LIBRE was compared against a conventional CHESS fat saturation (FS) and a binomial 1-180°-1 water excitation (WE) pulse. First, fat suppression of all techniques was numerically characterized using Matlab and experimentally validated in phantoms and in legs of human volunteers. Subsequently, free-breathing self-navigated coronary artery CMR was performed using the LIBRE pulse as well as FS and WE in ten healthy subjects. Myocardial, arterial and chest fat signal-to-noise ratios (SNR), as well as coronary vessel conspicuity were quantitatively compared among those scans. RESULTS The results obtained in the simulations were confirmed by the experimental validations as LIBRE enabled near complete fat suppression for 3D radial imaging in vitro and in vivo. For self-navigated whole-heart coronary artery CMR at 3 T, fat SNR was significantly attenuated using LIBRE compared with conventional FS. LIBRE increased the right coronary artery (RCA) vessel sharpness significantly (37 ± 9% (LIBRE) vs. 29 ± 8% (FS) and 30 ± 8% (WE), both p < 0.05) and led to a significant increase in the measured RCA vessel length to (83 ± 31 mm (LIBRE) vs. 56 ± 12 mm (FS) and 59 ± 27 (WE) p < 0.05). CONCLUSIONS Applied to a respiratory self-navigated noncontrast 3D radial whole-heart sequence, LIBRE enables robust large volume fat suppression and significantly improves coronary artery image quality at 3 T compared to the use of conventional FS and WE.
Collapse
Affiliation(s)
- Jessica A. M. Bastiaansen
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging, Lausanne, Switzerland
| | - Davide Piccini
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced clinical imaging technology, Siemens Healthcare AG, Lausanne, Switzerland
| |
Collapse
|
20
|
Delacoste J, Feliciano H, Yerly J, Dunet V, Beigelman‐Aubry C, Ginami G, van Heeswijk RB, Piccini D, Stuber M, Sauty A. A black‐blood ultra‐short echo time (UTE) sequence for 3D isotropic resolution imaging of the lungs. Magn Reson Med 2019; 81:3808-3818. [DOI: 10.1002/mrm.27679] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 12/14/2018] [Accepted: 01/08/2019] [Indexed: 12/23/2022]
Affiliation(s)
- Jean Delacoste
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
| | - Helene Feliciano
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
| | - Jérôme Yerly
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
- Center for Biomedical Imaging (CIBM) Lausanne Switzerland
| | - Vincent Dunet
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
| | - Catherine Beigelman‐Aubry
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
| | - Giulia Ginami
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
- School of Biomedical Engineering and Imaging Sciences King’s College London London United Kingdom
| | - Ruud B. van Heeswijk
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
- Center for Biomedical Imaging (CIBM) Lausanne Switzerland
| | - Davide Piccini
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
- Advanced Clinical Imaging Technology Siemens Healthcare AG Lausanne Switzerland
| | - Matthias Stuber
- Department of Radiology University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
- Center for Biomedical Imaging (CIBM) Lausanne Switzerland
| | - Alain Sauty
- Adult CF unit, Neuchatelois‐Pourtales Hospital Neuchatel Switzerland
- Service of Pneumology, Department of Medicine University Hospital (CHUV) Lausanne Switzerland
| |
Collapse
|
21
|
Yerly J, Becce F, van Heeswijk RB, Verdun FR, Gubian D, Meuli R, Stuber M. In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function. J Cardiovasc Magn Reson 2019; 21:11. [PMID: 30728035 PMCID: PMC6366062 DOI: 10.1186/s12968-019-0521-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Accepted: 01/14/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Our objectives were first to determine the optimal coronary computed tomography angiography (CTA) protocol for the quantification and detection of simulated coronary artery cross-sectional area (CSA) differences in vitro, and secondly to quantitatively compare the performance of the optimized CTA protocol with a previously validated radial coronary cardiovascular magnetic resonance (CMR) technique. METHODS 256-multidetector CTA and radial coronary CMR were used to obtain images of a custom in vitro resolution phantom simulating a range of physiological responses of coronary arteries to stress. CSAs were automatically quantified and compared with known nominal values to determine the accuracy, precision, signal-to-noise ratio (SNR), and circularity of CSA measurements, as well as the limit of detection (LOD) of CSA differences. Various iodine concentrations, radiation dose levels, tube potentials, and iterative image reconstruction algorithms (ASiR-V) were investigated to determine the optimal CTA protocol. The performance of the optimized CTA protocol was then compared with a radial coronary CMR method previously developed for endothelial function assessment under both static and moving conditions. RESULTS The iodine concentration, dose level, tube potential, and reconstruction algorithm all had significant effects (all p < 0.001) on the accuracy, precision, LOD, SNR, and circularity of CSA measurements with CTA. The best precision, LOD, SNR, and circularity with CTA were achieved with 6% iodine, 20 mGy, 100 kVp, and 90% ASiR-V. Compared with the optimized CTA protocol under static conditions, radial coronary CMR was less accurate (- 0.91 ± 0.13 mm2 vs. -0.35 ± 0.04 mm2, p < 0.001), but more precise (0.08 ± 0.02 mm2 vs. 0.21 ± 0.02 mm2, p < 0.001), and enabled the detection of significantly smaller CSA differences (0.16 ± 0.06 mm2 vs. 0.52 ± 0.04 mm2; p < 0.001; corresponding to CSA percentage differences of 2.3 ± 0.8% vs. 7.4 ± 0.6% for a 3-mm baseline diameter). The same results held true under moving conditions as CSA measurements with CMR were less affected by motion. CONCLUSIONS Radial coronary CMR was more precise and outperformed CTA for the specific task of detecting small CSA differences in vitro, and was able to reliably identify CSA changes an order of magnitude smaller than those reported for healthy physiological vasomotor responses of proximal coronary arteries. However, CTA yielded more accurate CSA measurements, which may prove useful in other clinical scenarios, such as coronary artery stenosis assessment.
Collapse
Affiliation(s)
- Jérôme Yerly
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Francis R. Verdun
- Institute of Radiation Physics, Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Danilo Gubian
- Direction des Constructions, Ingénierie, Technique et Sécurité (CIT-S), Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Reto Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|
22
|
Colotti R, Omoumi P, van Heeswijk RB, Bastiaansen JAM. Simultaneous fat-free isotropic 3D anatomical imaging and T 2 mapping of knee cartilage with lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses. J Magn Reson Imaging 2018; 49:1275-1284. [PMID: 30318667 DOI: 10.1002/jmri.26322] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Revised: 08/13/2018] [Accepted: 08/13/2018] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Improved knee cartilage morphological delineation and T2 mapping precision necessitates isotropic 3D high-resolution and efficient fat suppression. PURPOSE To develop and assess an isotropic 3D lipid-insensitive T2 mapping technique of the knee for improved cartilage delineation and precise measurement of T2 relaxation times. STUDY TYPE Prospective. PHANTOM/SUBJECTS Phantoms (n = 6) used in this study were designed to mimic the T1 and T2 relaxation times of cartilage and fat. The study cohort comprised healthy volunteers (n = 7) for morphometry and T2 relaxation time measurements. FIELD STRENGTH/SEQUENCE A high-resolution isotropic 3D T2 mapping technique that uses sequential T2 -prepared segmented gradient-recalled echo (Iso3DGRE) images and lipid-insensitive binomial off-resonant radiofrequency (RF) excitation (LIBRE) at 3T. ASSESSMENT Numerical simulations and phantom experiments were performed to optimize the LIBRE pulse. Phantom studies were carried out to test the accuracy of the technique against reference standard spin-echo (SE) T2 mapping. Subsequently, T2 maps with and without LIBRE pulses were acquired in knees of healthy volunteers and the T2 relaxation time values in different cartilage compartments were compared. STATISTICAL TESTS A two-tailed paired Student's t-test was used to compare the average T2 values and the relative standard deviations (inverse measurement of the precision) obtained with and without LIBRE pulses. RESULTS A LIBRE pulse of 1 msec suppressed fat with an RF excitation frequency offset of 1560 Hz and optimal RF excitation angle of 35°. These results were corroborated by phantom and knee experiments. Robust and homogeneous fat suppression was obtained (a fat signal-to-noise ratio (SNR) decrease of 86.4 ± 2.4%). In phantoms, T2 values were found in good agreement when comparing LIBRE-Iso3DGRE with SE (slope 0.93 ± 0.04, intercept 0.11 ± 1.6 msec, R2 >0.99). In vivo, LIBRE excitation resulted in more precise T2 estimation (23.7 ± 7.4%) than normal excitation (30.5 ± 9.9%, P < 0.0001). DATA CONCLUSION Homogeneous LIBRE fat signal suppression was achieved with a total RF pulse duration of 1 msec, allowing for the removal of chemical shift artifacts and resulting in improved cartilage delineation and precise T2 values. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1275-1284.
Collapse
Affiliation(s)
- Roberto Colotti
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Patrick Omoumi
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Centre for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
23
|
Darçot E, Yerly J, Colotti R, Masci PG, Chaptinel J, Feliciano H, Bianchi V, van Heeswijk RB. Accelerated and high-resolution cardiac T 2 mapping through peripheral k-space sharing. Magn Reson Med 2018; 81:220-233. [PMID: 30058085 DOI: 10.1002/mrm.27374] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 04/26/2018] [Accepted: 05/01/2018] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop high-spatial-resolution cardiac T2 mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and optimized a new golden-angle radial T2 mapping technique named SKRATCH (Shared k-space Radial T2 Characterization of the Heart) that shares k-space peripheries of T2 -weighted images while preserving their contrasts. METHODS Six SKRATCH variants (gradient-recalled echo and balanced SSFP, free-breathing and breath-held, with and without a saturation preparation) were implemented, and their precision was compared with a navigator-gated reference technique in phantoms and 22 healthy volunteers at 3 T. The optimal breath-held SKRATCH technique was applied in a small cohort of patients with subacute myocardial infarction. RESULTS The faster free-breathing SKRATCH technique reduced the acquisition time by 52.4%, while maintaining the precision and spatial resolution of the reference technique. Similarly, the most precise and robust breath-held SKRATCH technique demonstrated homogenous T2 values that did not significantly differ from the navigator-gated reference (T2 = 39.9 ± 3.4 ms versus 39.5 ± 3.4 ms, P > .20, respectively). All infarct patients demonstrated a large T2 elevation in the ischemic regions of the myocardium. CONCLUSION The optimized SKRATCH technique enabled the accelerated acquisition of high-spatial-resolution T2 maps, was validated in healthy adult volunteers, and was successfully applied to a small initial group of patients.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.,Center for Biomedical Imaging, Lausanne and Geneva, Switzerland
| | - Roberto Colotti
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Pier Giorgio Masci
- Center for Cardiac Magnetic Resonance, Cardiology Service, Lausanne University Hospital, Lausanne, Switzerland
| | - Jerome Chaptinel
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Helene Feliciano
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Veronica Bianchi
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.,Center for Biomedical Imaging, Lausanne and Geneva, Switzerland
| |
Collapse
|
24
|
Messroghli DR, Moon JC, Ferreira VM, Grosse-Wortmann L, He T, Kellman P, Mascherbauer J, Nezafat R, Salerno M, Schelbert EB, Taylor AJ, Thompson RB, Ugander M, van Heeswijk RB, Friedrich MG. Correction to: Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson 2018; 20:9. [PMID: 29415744 PMCID: PMC5804075 DOI: 10.1186/s12968-017-0408-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Accepted: 11/20/2017] [Indexed: 11/10/2022] Open
Abstract
CORRECTION TO J CARDIOVASC MAGN RESON (2017) 19: 75. DOI: 10.1186/S12968-017-0389-8: In the original publication of this article [1] the "Competing interests" section was incorrect. The original publication stated the following competing interests.
Collapse
Affiliation(s)
- Daniel R Messroghli
- Department of Internal Medicine and Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany.
- Department of Internal Medicine and Cardiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - James C Moon
- University College London and Barts Heart Centre, London, UK
| | - Vanessa M Ferreira
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Lars Grosse-Wortmann
- Division of Cardiology in the Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Taigang He
- Cardiovascular Science Research Centre, St George's, University of London, London, UK
| | | | - Julia Mascherbauer
- Department of Internal Medicine II, Division of Cardiology, Vienna, Austria
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| | - Michael Salerno
- Departments of Medicine Cardiology Division, Radiology and Medical Imaging, and Biomedical Engineering, University of Virginia Health System, Charlottesville, VA, USA
| | - Erik B Schelbert
- Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
- UPMC Cardiovascular Magnetic Resonance Center, Heart and Vascular Institute, Pittsburgh, PA, USA
- Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA, USA
| | - Andrew J Taylor
- Department of Cardiovascular Medicine, Alfred Hospital and Baker Heart and Diabetes Institute, Melbourne, Australia
| | - Richard B Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, Canada
| | - Martin Ugander
- Department of Clinical Physiology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden
| | - Ruud B van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and Lausanne University (UNIL), Lausanne, Switzerland
| | - Matthias G Friedrich
- Departments of Medicine and Diagnostic Radiology, McGill University, Montréal, Québec, Canada
- Department of Medicine, Heidelberg University, Heidelberg, Germany
- Département de radiologie, Université de Montréal, Montréal, Québec, Canada
- Departments of Cardiac Sciences and Radiology, University of Calgary, Calgary, Canada
| |
Collapse
|
25
|
Bouchoucha M, van Heeswijk RB, Gossuin Y, Kleitz F, Fortin MA. Fluorinated Mesoporous Silica Nanoparticles for Binuclear Probes in 1H and 19F Magnetic Resonance Imaging. Langmuir 2017; 33:10531-10542. [PMID: 28869376 DOI: 10.1021/acs.langmuir.7b01792] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The development of molecular and cellular magnetic resonance imaging (MRI) procedures has always represented a challenge because of the fact that conventional MRI contrast agents are not directly detected in vivo; in proton MRI (e.g., with the nucleus 1H), their local concentration is measured through the effect they exert on the signal of hydrogen protons present in their immediate vicinity. Because the contrast effects generated by conventional MRI probes superpose to and can often impede the anatomical information contained in 1H MRI images, new probes based on a nucleus other than 1H, are being developed. In this study, we report on the development of fluorinated mesoporous silica nanoparticles (MSNs), which could represent an interesting dual probe that allows two MRI modes: 1H for high-resolution anatomical information and 19F for the detection of MSNs used as drug delivery agents. MSNs were synthesized and covalently functionalized either with fluorosilane (FMSNs) or polyfluorosiloxane (polyFMSNs) to enable their detection in 19F MRI. Then, gadolinium chelates were grafted on the particles to enhance their detectability in 1H MRI. The physicochemical, textural, and relaxometric properties (1H and 19F relaxation times) of the nanoparticles were measured and compared. The 19F relaxation properties were found to be dependent on the concentration of fluorine; they were also highly sensitive to the presence of gadolinium. The shortest relaxation times were obtained with polyFMSNs. At clinical magnetic field strengths, high 1H relaxivities and low relaxometric ratios (r2/r1 = 1.45; 2.2 for nanoparticles entrapped in hydrogel) were found for both nanoparticle systems. Finally, the visibility of both systems was confirmed in 1H, and the detectability of polyFMSNs was confirmed in 19F MRI. This physicochemical and relaxometric study opens the door to the applications of fluorinated silica nanoparticles as theranostic materials allowing dual MRI (1H and 19F).
Collapse
Affiliation(s)
- Meryem Bouchoucha
- Department of Mining, Metallurgy and Materials Engineering, Université Laval and Centre de Recherche du Centre Hospitalier Universitaire de Québec (CR-CHUQ), Axe Médecine Régénératrice , Québec, Quebec G1L 3L5, Canada
| | - Ruud B van Heeswijk
- Department of Radiology, Centre Hospitalier Universitaire Vaudois (CHUV) , 1011 Lausanne, Switzerland
| | - Yves Gossuin
- Service de Physique Expérimentale et Biologique, Université de Mons , 24 Avenue du Champ-de-Mars, 7000 Mons, Belgium
| | | | - Marc-André Fortin
- Department of Mining, Metallurgy and Materials Engineering, Université Laval and Centre de Recherche du Centre Hospitalier Universitaire de Québec (CR-CHUQ), Axe Médecine Régénératrice , Québec, Quebec G1L 3L5, Canada
| |
Collapse
|
26
|
Messroghli DR, Moon JC, Ferreira VM, Grosse-Wortmann L, He T, Kellman P, Mascherbauer J, Nezafat R, Salerno M, Schelbert EB, Taylor AJ, Thompson R, Ugander M, van Heeswijk RB, Friedrich MG. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson 2017; 19:75. [PMID: 28992817 PMCID: PMC5633041 DOI: 10.1186/s12968-017-0389-8] [Citation(s) in RCA: 952] [Impact Index Per Article: 136.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Accepted: 09/25/2017] [Indexed: 12/14/2022] Open
Abstract
Parametric mapping techniques provide a non-invasive tool for quantifying tissue alterations in myocardial disease in those eligible for cardiovascular magnetic resonance (CMR). Parametric mapping with CMR now permits the routine spatial visualization and quantification of changes in myocardial composition based on changes in T1, T2, and T2*(star) relaxation times and extracellular volume (ECV). These changes include specific disease pathways related to mainly intracellular disturbances of the cardiomyocyte (e.g., iron overload, or glycosphingolipid accumulation in Anderson-Fabry disease); extracellular disturbances in the myocardial interstitium (e.g., myocardial fibrosis or cardiac amyloidosis from accumulation of collagen or amyloid proteins, respectively); or both (myocardial edema with increased intracellular and/or extracellular water). Parametric mapping promises improvements in patient care through advances in quantitative diagnostics, inter- and intra-patient comparability, and relatedly improvements in treatment. There is a multitude of technical approaches and potential applications. This document provides a summary of the existing evidence for the clinical value of parametric mapping in the heart as of mid 2017, and gives recommendations for practical use in different clinical scenarios for scientists, clinicians, and CMR manufacturers.
Collapse
Affiliation(s)
- Daniel R. Messroghli
- Department of Internal Medicine and Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
- Department of Internal Medicine and Cardiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - James C. Moon
- University College London and Barts Heart Centre, London, UK
| | - Vanessa M. Ferreira
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Lars Grosse-Wortmann
- Division of Cardiology in the Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON Canada
| | - Taigang He
- Cardiovascular Science Research Centre, St George’s, University of London, London, UK
| | | | - Julia Mascherbauer
- Department of Internal Medicine II, Division of Cardiology, Vienna, Austria
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| | - Michael Salerno
- Departments of Medicine Cardiology Division, Radiology and Medical Imaging, and Biomedical Engineering, University of Virginia Health System, Charlottesville, VA USA
| | - Erik B. Schelbert
- Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, PA USA
- UPMC Cardiovascular Magnetic Resonance Center, Heart and Vascular Institute, Pittsburgh, PA USA
- Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA USA
| | - Andrew J. Taylor
- The Alfred Hospital, Baker Heart and Diabetes Institute, Melbourne, Australia
| | - Richard Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, Canada
| | - Martin Ugander
- Department of Clinical Physiology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden
| | - Ruud B. van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and Lausanne University (UNIL), Lausanne, Switzerland
| | - Matthias G. Friedrich
- Departments of Medicine and Diagnostic Radiology, McGill University, Montréal, Québec Canada
- Department of Medicine, Heidelberg University, Heidelberg, Germany
- Département de radiologie, Université de Montréal, Montréal, Québec Canada
- Departments of Cardiac Sciences and Radiology, University of Calgary, Calgary, Canada
| |
Collapse
|
27
|
van Heeswijk RB, Colotti R, Darçot E, Delacoste J, Pellegrin M, Piccini D, Hernando D. Chemical shift encoding (CSE) for sensitive fluorine-19 MRI of perfluorocarbons with complex spectra. Magn Reson Med 2017; 79:2724-2730. [PMID: 28862351 DOI: 10.1002/mrm.26895] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 08/07/2017] [Accepted: 08/09/2017] [Indexed: 12/13/2022]
Abstract
PURPOSE To implement a fluorine-19 (19 F) chemical shift encoding (CSE) approach for the sensitive imaging of molecules with multi-resonance spectra to remove their chemical shift displacement (CSD) artifacts, and to characterize its sensitivity versus established pulse sequences. METHODS The feasibility of CSE spoiled gradient echo (GRE) and balanced steady-state free precession (bSSFP) was first demonstrated in a phantom study. The dependence of the sensitivity of CSE-bSSFP on several pulse sequence parameters was then established, after which the occurrence of out-of-plane excitation was assessed for 2D and 3D techniques. Next, the sensitivity (in mm-3 s-0.5 ) of both CSE techniques was compared to bSSFP ultrashort echo time (bSSFP-UTE) imaging and multi-chemical-shift-selective turbo spin echo (MCSS-TSE) in a second phantom study. Finally, the sensitivity of the CSE-bSSFP, bSSFP-UTE, and MCSS-TSE pulse sequences was compared in a preliminary in vivo mouse study. RESULTS Both CSE approaches were successfully implemented and resulted in negligible residual CSD artifacts, while large-volume 3D acquisitions should be considered to reduce problems related to out-of-plane excitation. CSE-bSSFP was shown to have a higher sensitivity than the bSSFP-UTE and MCSS-TSE pulse sequences (15.8 ± 1.3 vs. 11.7 ± 1.0 vs. 13.3 ± 0.9 mm-3 s-0.5 , respectively, P < 0.001), whereas CSE-GRE technique had a lower sensitivity (4.8 ± 1.1 mm-3 s-0.5 ). CONCLUSION CSE 19 F MR imaging enables the unambiguous visualization of compounds with complex spectra, and provides high sensitivity both in vitro and in vivo. Magn Reson Med 79:2724-2730, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ruud B van Heeswijk
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Roberto Colotti
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Emeline Darçot
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jean Delacoste
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Maxime Pellegrin
- Division of Angiology, Heart and Vessel Department, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Davide Piccini
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Diego Hernando
- Department of Radiology, University of Wisconsin-Madison, Madison Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
28
|
Ludwig KD, Hernando D, Roberts NT, van Heeswijk RB, Fain SB. A chemical shift encoding (CSE) approach for spectral selection in fluorine-19 MRI. Magn Reson Med 2017; 79:2183-2189. [PMID: 28833448 DOI: 10.1002/mrm.26874] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 07/25/2017] [Accepted: 07/25/2017] [Indexed: 01/05/2023]
Abstract
PURPOSE To develop a chemical shift encoding (CSE) approach for fluorine-19 MRI of perfluorocarbons in the presence of multiple known fluorinated chemical species. THEORY AND METHODS A multi-echo CSE technique is applied for spectral separation of the perfluorocarbon perfluoro-15-crown-5-ether (PFCE) and isoflurane (ISO) based on their chemical shifts at 4.7 T. Cramér-Rao lower bound analysis is used to identify echo combinations with optimal signal-to-noise performance. Signal contributions are fit with a multispectral fluorine signal model using a non-linear least squares estimation reconstruction directly from k-space data. This CSE approach is tested in fluorine-19 phantoms and in a mouse with a 2D and 3D spoiled gradient-echo acquisition using multiple echo times determined from Cramér-Rao lower bound analysis. RESULTS Cramér-Rao lower bound analysis for PFCE and ISO separation shows signal-to-noise performance is maximized with a 0.33 ms echo separation. A linear behavior (R2 = 0.987) between PFCE signal and known relative PFCE volume is observed in CSE reconstructed images using a mixed PFCE/ISO phantom. Effective spatial and spectral separation of PFCE and ISO is shown in phantoms and in vivo. CONCLUSION Feasibility of a gradient-echo CSE acquisition and image reconstruction approach with optimized noise performance is demonstrated through fluorine-19 MRI of PFCE with effective removal of ISO signal contributions. Magn Reson Med 79:2183-2189, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Kai D Ludwig
- Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Diego Hernando
- Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Nathan T Roberts
- Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Ruud B van Heeswijk
- Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Sean B Fain
- Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
29
|
Colotti R, Omoumi P, Bonanno G, Ledoux JB, van Heeswijk RB. Isotropic three-dimensionalT2mapping of knee cartilage: Development and validation. J Magn Reson Imaging 2017; 47:362-371. [DOI: 10.1002/jmri.25755] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 04/18/2017] [Indexed: 12/25/2022] Open
Affiliation(s)
- Roberto Colotti
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| | - Patrick Omoumi
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| | - Gabriele Bonanno
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
- Division of Cardiology, Department of Medicine; Johns Hopkins University; Baltimore Maryland USA
- Division of MR Research, Russell Morgan Department of Radiology and Radiological Sciences; Johns Hopkins University; Baltimore Maryland USA
| | - Jean-Baptiste Ledoux
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
- Centre for Biomedical Imaging (CIBM); Lausanne Switzerland
| | - Ruud B. van Heeswijk
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| |
Collapse
|
30
|
Lugand E, Yerly J, Feliciano H, Chaptinel J, Stuber M, van Heeswijk RB. Breath-held high-resolution cardiac T2 mapping with SKRATCH. J Cardiovasc Magn Reson 2016. [PMCID: PMC5032436 DOI: 10.1186/1532-429x-18-s1-p27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
31
|
van Heeswijk RB, Feliciano H, Metrich M, Piccini D, Rotman S, Schwitter J, Hullin R. Initial experience with isotropic 3D cardiac T2 mapping for the monitoring of cardiac allograft rejection. J Cardiovasc Magn Reson 2016. [PMCID: PMC5032766 DOI: 10.1186/1532-429x-18-s1-w23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
32
|
Colotti R, Bastiaansen JAM, Wilson A, Flögel U, Gonzales C, Schwitter J, Stuber M, van Heeswijk RB. Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla. Magn Reson Med 2016; 77:2263-2271. [PMID: 27385530 DOI: 10.1002/mrm.26317] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Revised: 05/12/2016] [Accepted: 05/31/2016] [Indexed: 12/22/2022]
Abstract
PURPOSE To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ether (PFCE), and perfluorooctyl bromide (PFOB) were measured in phantoms and in several different conditions (cell types, presence of fixation agent, and temperatures). These relaxation times were used to optimize pulse sequences through numerical simulations. The acquisition efficiency in each cellular condition was then determined as the ratio of the signal after optimization with the reference relaxation times and after optimization with its proper relaxation times. Finally, PFC detection limits were determined. RESULTS The loss of acquisition efficiency due to parameter settings optimized for the wrong temperature and cellular condition was limited to 13%. The detection limits of all PFCs were lower at 24 °C than at 37 °C and varied from 11.8 ± 3.0 mM for PFCE at 24 °C to 379.9 ± 51.8 mM for PFOB at 37 °C. CONCLUSION Optimizing 19 F pulse sequences with a known phantom only leads to moderate loss in acquisition efficiency in cellular conditions that might be encountered in in vivo and in vitro experiments. Magn Reson Med 77:2263-2271, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Roberto Colotti
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Anne Wilson
- Ludwig Center for Cancer Research, University of Lausanne (UNIL), Epalinges, Switzerland
| | - Ulrich Flögel
- Department of Cardiovascular Physiology, Heinrich Heine University, Düsseldorf, Germany
| | - Christine Gonzales
- Division of Cardiology and Cardiac MR Center, Department of Internal Medicine, University Hospital of Lausanne (CHUV), Lausanne, Switzerland
| | - Juerg Schwitter
- Division of Cardiology and Cardiac MR Center, Department of Internal Medicine, University Hospital of Lausanne (CHUV), Lausanne, Switzerland
| | - Matthias Stuber
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne and Geneva, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
33
|
Bano W, Feliciano H, Coristine AJ, Stuber M, van Heeswijk RB. On the accuracy and precision of cardiac magnetic resonance T 2 mapping: A high-resolution radial study using adiabatic T 2 preparation at 3 T. Magn Reson Med 2016; 77:159-169. [PMID: 26762815 DOI: 10.1002/mrm.26107] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 12/02/2015] [Accepted: 12/03/2015] [Indexed: 11/07/2022]
Abstract
PURPOSE The goal of this study was to characterize the accuracy and precision of cardiac T2 mapping as a function of different factors including low signal-to-noise ratio (SNR), imaging in systole, and off-resonance frequencies. METHODS Bloch equation and Monte Carlo simulations were used to determine the influence of SNR and the choice of T2 preparation echo time (TET2prep ) increments on the accuracy and precision of high-resolution radial cardiac T2 mapping at 3.0 T. Healthy volunteers were scanned to establish the difference in precision and inter- and intraobserver variability between T2 mapping in diastole and systole, as well as the effect of SNR and off-resonance frequencies on the accuracy of T2 maps. RESULTS The simulations demonstrated that a TET2prep increment of ∼0.75 times the T2 value of interest optimally increases the precision of the T2 fit. Systolic T2 maps were found to have a higher precision (P = 0.002), but similar inter- and intraobserver variability compared with diastolic T2 maps, whereas off-resonance frequencies beyond ± 100 Hz cause a significant decrease in both accuracy and precision (P < 0.05). CONCLUSION This evaluation of the accuracy and precision of cardiac T2 mapping characterizes the major vulnerabilities of the technique and will help guide protocol definition of studies that include T2 mapping. Magn Reson Med 77:159-169, 2017. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Wajiha Bano
- Cardiovascular Magnetic Resonance Research Center, Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hélène Feliciano
- Cardiovascular Magnetic Resonance Research Center, Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Andrew J Coristine
- Cardiovascular Magnetic Resonance Research Center, Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Matthias Stuber
- Cardiovascular Magnetic Resonance Research Center, Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Cardiovascular Magnetic Resonance Research Center, Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
34
|
Viallon M, moulin K, Goff C, Didier J, van Heeswijk RB, Stuber M, Bourguignon C, Gergelé L, Millet GP, Beuf O, Croisille P. Apparent Diffusion coefficient (ADC), T1 and T2 quantitative indexes of the myocardium in athletes before, during and after extreme mountain ultra-marathon: correlation with myocardial damages and inflammation biomarkers. Journal of Cardiovascular Magnetic Resonance 2016. [PMCID: PMC5032786 DOI: 10.1186/1532-429x-18-s1-o41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
35
|
Lugand E, Yerly J, Feliciano H, Chaptinel J, Stuber M, van Heeswijk RB. Accelerated and KWIC-filtered cardiac T2 mapping for improved precision: proof of principle. J Cardiovasc Magn Reson 2015. [PMCID: PMC4328692 DOI: 10.1186/1532-429x-17-s1-w30] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
36
|
Balzan R, Mishkovsky M, Simonenko Y, van Heeswijk RB, Gruetter R, Eliav U, Navon G, Comment A. Hyperpolarized (6)Li as a probe for hemoglobin oxygenation level. Contrast Media Mol Imaging 2015; 11:41-6. [PMID: 26265292 DOI: 10.1002/cmmi.1656] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Accepted: 06/08/2015] [Indexed: 11/10/2022]
Abstract
Hyperpolarization by dissolution dynamic nuclear polarization (DNP) is a versatile technique to dramatically enhance the nuclear magnetic resonance (NMR) signal intensity of insensitive long-T1 nuclear spins such as (6)Li. The (6)Li longitudinal relaxation of lithium ions in aqueous solutions strongly depends on the concentration of paramagnetic species, even if they are present in minute amounts. We herein demonstrate that blood oxygenation can be readily detected by taking advantage of the (6)Li signal enhancement provided by dissolution DNP, together with the more than 10% decrease in (6)Li longitudinal relaxation as a consequence of the presence of paramagnetic deoxyhemoglobin.
Collapse
Affiliation(s)
- Riccardo Balzan
- Institute of Physics of Biological Systems, Ecole Polytechnique Fédérale de Lausanne, CH-1015, Lausanne, Switzerland
| | - Mor Mishkovsky
- Laboratory for Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, CH-1015, Lausanne, Switzerland.,Department of Radiology, Université de Lausanne, CH-1015, Lausanne, Switzerland
| | - Yana Simonenko
- School of Chemistry, Tel-Aviv University, Ramat-Aviv, Tel Aviv, Israel
| | - Ruud B van Heeswijk
- Department of Radiology, Université de Lausanne, CH-1015, Lausanne, Switzerland.,Center of Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Rolf Gruetter
- Laboratory for Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, CH-1015, Lausanne, Switzerland.,Department of Radiology, Université de Lausanne, CH-1015, Lausanne, Switzerland.,Department of Radiology, Geneva University Hospital and Faculty of Medicine, University of Geneva, CH-1211, Genève 4, Switzerland
| | - Uzi Eliav
- School of Chemistry, Tel-Aviv University, Ramat-Aviv, Tel Aviv, Israel
| | - Gil Navon
- School of Chemistry, Tel-Aviv University, Ramat-Aviv, Tel Aviv, Israel
| | - Arnaud Comment
- Institute of Physics of Biological Systems, Ecole Polytechnique Fédérale de Lausanne, CH-1015, Lausanne, Switzerland
| |
Collapse
|
37
|
van Heeswijk RB, Pellegrin M, Flögel U, Gonzales C, Aubert JF, Mazzolai L, Schwitter J, Stuber M. Fluorine MR Imaging of Inflammation in Atherosclerotic Plaque in Vivo. Radiology 2015; 275:421-9. [DOI: 10.1148/radiol.14141371] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
38
|
Coppo S, Piccini D, Bonanno G, Chaptinel J, Vincenti G, Feliciano H, van Heeswijk RB, Schwitter J, Stuber M. Free-running 4D whole-heart self-navigated golden angle MRI: Initial results. Magn Reson Med 2014; 74:1306-16. [PMID: 25376772 DOI: 10.1002/mrm.25523] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 10/01/2014] [Accepted: 10/16/2014] [Indexed: 12/22/2022]
Abstract
PURPOSE To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3). Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence.
Collapse
Affiliation(s)
- Simone Coppo
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Davide Piccini
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Advanced Clinical Imaging Technology, Siemens Healthcare IM BM PI, Lausanne, Switzerland
| | - Gabriele Bonanno
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jérôme Chaptinel
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Gabriella Vincenti
- Department of Cardiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Hélène Feliciano
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Juerg Schwitter
- Department of Cardiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Matthias Stuber
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
39
|
Coristine AJ, van Heeswijk RB, Stuber M. Fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T 2-preparation technique. Magn Reson Med 2014. [DOI: 10.1002/mrm.25428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Andrew J. Coristine
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Matthias Stuber
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| |
Collapse
|
40
|
Coristine AJ, van Heeswijk RB, Stuber M. Combined T2-preparation and two-dimensional pencil-beam inner volume selection. Magn Reson Med 2014; 74:529-36. [DOI: 10.1002/mrm.25442] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Revised: 08/13/2014] [Accepted: 08/14/2014] [Indexed: 11/09/2022]
Affiliation(s)
- Andrew J. Coristine
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Matthias Stuber
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| |
Collapse
|
41
|
Coppo S, Firsova M, Locca D, Knebel JF, van Heeswijk RB, Stuber M. Repositioning precision of coronary arteries measured on X-ray angiography and its implications for coronary MR angiography. J Magn Reson Imaging 2014; 41:1251-8. [DOI: 10.1002/jmri.24685] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2014] [Revised: 06/11/2014] [Accepted: 06/11/2014] [Indexed: 11/08/2022] Open
Affiliation(s)
- Simone Coppo
- Center for Biomedical Imaging (CIBM); Lausanne Switzerland
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| | - Maria Firsova
- Center for Biomedical Imaging (CIBM); Lausanne Switzerland
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| | - Didier Locca
- Department of Cardiology; University Hospital (CHUV); Lausanne Switzerland
- Barts and The London Chest Hospital; Queen Mary University London; London United Kingdom
| | - Jean-François Knebel
- Neuropsychology and Neurorehabilitation Service, DNC; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
- NCCR “SYNAPSY - The Synaptic Bases of Mental Diseases”; Lausanne Switzerland
| | - Ruud B. van Heeswijk
- Center for Biomedical Imaging (CIBM); Lausanne Switzerland
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| | - Matthias Stuber
- Center for Biomedical Imaging (CIBM); Lausanne Switzerland
- Department of Radiology; University Hospital (CHUV) and University of Lausanne (UNIL); Lausanne Switzerland
| |
Collapse
|
42
|
van Heeswijk RB, Piccini D, Feliciano H, Hullin R, Schwitter J, Stuber M. Self-navigated isotropic three-dimensional cardiac T2 mapping. Magn Reson Med 2014; 73:1549-54. [PMID: 24809849 DOI: 10.1002/mrm.25258] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 02/20/2014] [Accepted: 03/29/2014] [Indexed: 11/11/2022]
Abstract
PURPOSE To implement and characterize an isotropic three-dimensional cardiac T2 mapping technique. METHODS A self-navigated three-dimensional radial segmented balanced steady-state free precession pulse sequence with an isotropic 1.7-mm spatial resolution was implemented at 3T with a variable T2 preparation module. Bloch equation and Monte Carlo simulations were performed to determine the influence of the heart rate, B1 inhomogeneity and noise on the T2 fitting accuracy. In a phantom study, the accuracy of the pulse sequence was studied through comparison with a gold-standard spin-echo T2 mapping method. The robustness and homogeneity of the technique were ascertained in a study of 10 healthy adult human volunteers, while first results obtained in patients are reported. RESULTS The numerical simulations demonstrated that the heart rate and B1 inhomogeneity cause only minor deviations in the T2 fitting, whereas the phantom study showed good agreement of the technique with the gold standard. The volunteer study demonstrated an average myocardial T2 of 40.5 ± 3.3 ms and a <15% T2 gradient in the base-apex and anterior-inferior direction. In three patients, elevated T2 values were measured in regions with expected edema. CONCLUSION This respiratory self-navigated isotropic three-dimensional technique allows for accurate and robust in vitro and in vivo T2 quantification.
Collapse
Affiliation(s)
- Ruud B van Heeswijk
- Department of Radiology, CardioVascular Magnetic Resonance (CVMR), University Hospital (CHUV) and University (UNIL) of Lausanne, Lausanne, Switzerland; Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | | | | | | | | | | |
Collapse
|
43
|
van Heeswijk RB, Vincenti G, Monney P, Kourda J, Rotman S, Stuber M, Schwitter J, Hullin R. Free-breathing T2 mapping at 3T for the monitoring of cardiac allograft rejection: initial results. J Cardiovasc Magn Reson 2014. [PMCID: PMC4043701 DOI: 10.1186/1532-429x-16-s1-m11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
44
|
Feliciano H, Stuber M, van Heeswijk RB. Radial cardiac T2 mapping with alternating T2 preparation intrinsically introduces motion correction. J Cardiovasc Magn Reson 2014. [PMCID: PMC4042471 DOI: 10.1186/1532-429x-16-s1-p28] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
45
|
van Heeswijk RB, O'Brien KR, Delacoste J, Stuber M. Numerically optimized radiofrequency pulses for robust and low-power cardiovascular T2 preparation at 3T. J Cardiovasc Magn Reson 2014. [PMCID: PMC4043734 DOI: 10.1186/1532-429x-16-s1-p41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
46
|
Piccini D, Monney P, Sierro C, Coppo S, Bonanno G, van Heeswijk RB, Chaptinel J, Vincenti G, de Blois J, Koestner SC, Rutz T, Littmann A, Zenge MO, Schwitter J, Stuber M. Respiratory self-navigated postcontrast whole-heart coronary MR angiography: initial experience in patients. Radiology 2013; 270:378-86. [PMID: 24471387 DOI: 10.1148/radiol.13132045] [Citation(s) in RCA: 82] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PURPOSE To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. MATERIALS AND METHODS Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. RESULTS When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. CONCLUSION The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.
Collapse
Affiliation(s)
- Davide Piccini
- From Advanced Clinical Imaging Technology, Siemens Healthcare IM BM PI, Lausanne, Switzerland (D.P.); Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland (D.P., S.C., G.B., R.B.v.H., J.C., M.S.); Center for Biomedical Imaging, Centre Hospitalier Universitaire Vaudois, rue de Bugnon 46, BH 8.80, 1011 Lausanne, Switzerland (D.P., S.C., G.B., R.B.v.H., J.C., M.S.); Pattern Recognition Laboratory, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, Erlangen, Germany (D.P.); Division of Cardiology and Cardiac MR Center, University Hospital of Lausanne, Lausanne, Switzerland (P.M., C.S., G.V., J.d.B., S.C.K., T.R., J.S.); and MR Research and Development (A.L.), MR Product Innovation and Definition (M.O.Z.), Healthcare Sector, Siemens, Erlangen, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Coristine AJ, van Heeswijk RB, Stuber M. Fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T2-preparation technique. Magn Reson Med 2013; 72:763-9. [DOI: 10.1002/mrm.24961] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Revised: 08/21/2013] [Accepted: 08/29/2013] [Indexed: 11/11/2022]
Affiliation(s)
- Andrew J. Coristine
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| | - Matthias Stuber
- Department of Radiology; University Hospital (CHUV) / University of Lausanne (UNIL); Lausanne VD Switzerland
- CardioVascular Magnetic Resonance (CVMR); Research Centre, Centre for BioMedical Imaging (CIBM); Lausanne VD Switzerland
| |
Collapse
|
48
|
van Heeswijk RB, De Blois J, Kania G, Gonzales C, Blyszczuk P, Stuber M, Eriksson U, Schwitter J. Selective in vivo visualization of immune-cell infiltration in a mouse model of autoimmune myocarditis by fluorine-19 cardiac magnetic resonance. Circ Cardiovasc Imaging 2013; 6:277-84. [PMID: 23343515 DOI: 10.1161/circimaging.112.000125] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND The goal of this study was to characterize the performance of fluorine-19 ((19)F) cardiac magnetic resonance (CMR) for the specific detection of inflammatory cells in a mouse model of myocarditis. Intravenously administered perfluorocarbons are taken up by infiltrating inflammatory cells and can be detected by (19)F-CMR. (19)F-labeled cells should, therefore, generate an exclusive signal at the inflamed regions within the myocardium. METHODS AND RESULTS Experimental autoimmune myocarditis was induced in BALB/c mice. After intravenous injection of 2×200 µL of a perfluorocarbon on day 19 and 20 (n=9) after immunization, in vivo (19)F-CMR was performed at the peak of myocardial inflammation (day 21). In 5 additional animals, perfluorocarbon combined with FITC (fluorescein isothiocyanate) was administered for postmortem immunofluorescence and flow-cytometry analyses. Control experiments were performed in 9 animals. In vivo (19)F-CMR detected myocardial inflammation in all experimental autoimmune myocarditis-positive animals. Its resolution was sufficient to identify even small inflammatory foci, that is, at the surface of the right ventricle. Postmortem immunohistochemistry and flow cytometry confirmed the presence of perfluorocarbon in macrophages, dendritic cells, and granulocytes, but not in lymphocytes. The myocardial volume of elevated (19)F signal (rs=0.96; P<0.001), the (19)F signal-to-noise ratio (rs=0.92; P<0.001), and the (19)F signal integral (rs=0.96; P<0.001) at day 21 correlated with the histological myocarditis severity score. CONCLUSIONS In vivo (19)F-CMR was successfully used to visualize the inflammation specifically and robustly in experimental autoimmune myocarditis, and thus allowed for an unprecedented insight into the involvement of inflammatory cells in the disease process.
Collapse
|
49
|
van Heeswijk RB, Piccini D, Feliciano H, Schwitter J, Stuber M. Self-navigated three-dimensional cardiac T2 mapping at 3T. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559966 DOI: 10.1186/1532-429x-15-s1-p51] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
50
|
Coristine AJ, van Heeswijk RB, Stuber M. Improved fat signal suppression for coronary MRA at 3T using a water-selective adiabatic T2-Prep technique. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559462 DOI: 10.1186/1532-429x-15-s1-o5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
|