1
|
Simultaneous quantification of hyperpolarized xenon-129 ventilation and gas exchange with multi-breath xenon-polarization transfer contrast (XTC) MRI. Magn Reson Med 2023; 90:2334-2347. [PMID: 37533368 PMCID: PMC10543483 DOI: 10.1002/mrm.29804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 06/21/2023] [Accepted: 07/05/2023] [Indexed: 08/04/2023]
Abstract
PURPOSE To demonstrate the feasibility of a multi-breath xenon-polarization transfer contrast (XTC) MR imaging approach for simultaneously evaluating regional ventilation and gas exchange parameters. METHODS Imaging was performed in five healthy volunteers and six chronic obstructive pulmonary disease (COPD) patients. The multi-breath XTC protocol consisted of three repeated schemes of six wash-in breaths of a xenon mixture and four normoxic wash-out breaths, with and without selective saturation of either the tissue membrane or red blood cell (RBC) resonances. Acquisitions were performed at end-exhalation while subjects maintained tidal breathing throughout the session. The no-saturation, membrane-saturation, and RBC-saturation images were fit to a per-breath gas replacement model for extracting voxelwise tidal volume (TV), functional residual capacity (FRC), and fractional ventilation (FV), as well as tissue- and RBC-gas exchange (fMem and fRBC , respectively). The sensitivity of the derived model was also evaluated via simulations. RESULTS With the exception of FRC, whole-lung averages for all metrics were decreased in the COPD subjects compared to the healthy cohort, significantly so for FV, fRBC , and fMem . Heterogeneity was higher overall in the COPD subjects, particularly for fRBC , fMem , and fRBC:Mem . The anterior-to-posterior gradient associated with the gravity-dependence of lung function in supine imaging was also evident for FV, fRBC , and fMem values in the healthy subjects, but noticeably absent in the COPD cohort. CONCLUSION Multi-breath XTC imaging generated high-resolution, co-registered maps of ventilation and gas exchange parameters acquired during tidal breathing and with low per-breath xenon doses. Clear differences between healthy and COPD subjects were apparent and consistent with spirometry.
Collapse
|
2
|
Quantitative Measure of Lung Structure and Function Obtained from Hyperpolarized Xenon Spectroscopy. J Vis Exp 2023. [PMID: 38009715 DOI: 10.3791/66038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023] Open
Abstract
Hyperpolarized Xenon-129 (HXe) magnetic resonance imaging (MRI) provides tools for obtaining 2- or 3-dimensional maps of lung ventilation patterns, gas diffusion, Xenon uptake by lung parenchyma, and other lung function metrics. However, by trading spatial for temporal resolution, it also enables tracing of pulmonary Xenon gas exchange on a ms timescale. This article describes one such technique, chemical shift saturation recovery (CSSR) MR spectroscopy. It illustrates how it can be used to assess capillary blood volume, septal wall thickness, and the surface-to-volume ratio in the alveoli. The flip angle of the applied radiofrequency pulses (RF) was carefully calibrated. Single-dose breath-hold and multi-dose free-breathing protocols were employed for administering the gas to the subject. Once the inhaled Xenon gas reached the alveoli, a series of 90° RF pulses was applied to ensure maximum saturation of the accumulated Xenon magnetization in the lung parenchyma. Following a variable delay time, spectra were acquired to quantify the regrowth of the Xenon signal due to gas exchange between the alveolar gas volume and the tissue compartments of the lung. These spectra were then analyzed by fitting complex pseudo-Voigt functions to the three dominant peaks. Finally, the delay time-dependent peak amplitudes were fitted to a one-dimensional analytical gas-exchange model to extract physiological parameters.
Collapse
|
3
|
Imatinib alleviates lung injury and prolongs survival in ventilated rats. Am J Physiol Lung Cell Mol Physiol 2022; 322:L866-L872. [PMID: 35438574 PMCID: PMC9142156 DOI: 10.1152/ajplung.00006.2022] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 03/28/2022] [Accepted: 04/13/2022] [Indexed: 11/22/2022] Open
Abstract
Imatinib, a tyrosine kinase inhibitor, attenuates pulmonary edema and inflammation in lung injury. However, the physiological effects of this drug and their impact on outcomes are poorly characterized. Using serial computed tomography (CT), we tested the hypothesis that imatinib reduces injury severity and improves survival in ventilated rats. Hydrochloric acid (HCl) was instilled in the trachea (pH 1.5, 2.5 mL/kg) of anesthetized, intubated supine rats. Animals were randomized (n = 17 each group) to receive intraperitoneal imatinib or vehicle immediately prior to HCl. All rats then received mechanical ventilation. CT was performed hourly for 4 h. Images were quantitatively analyzed to assess the progression of radiological abnormalities. Injury severity was confirmed via hourly blood gases, serum biomarkers, bronchoalveolar lavage (BAL), and histopathology. Serial blood drug levels were measured in a subset of rats. Imatinib reduced mortality while delaying functional and radiological injury progression: out of 17 rats per condition, 2 control vs. 8 imatinib-treated rats survived until the end of the experiment (P = 0.02). Imatinib attenuated edema after lung injury (P < 0.05), and survival time in both groups was negatively correlated with increased lung mass (R2 = 0.70) as well as other physiological and CT parameters. Capillary leak (BAL protein concentration) was significantly lower in the treated group (P = 0.04). Peak drug concentration was reached after 70 min, and the drug half-life was 150 min. Imatinib decreased both mortality and lung injury severity in mechanically ventilated rats. Pharmacological inhibition of edema could be used during mechanical ventilation to improve the severity and outcome of lung injury.
Collapse
|
4
|
Simultaneous Imaging of Ventilation and Gas Exchange with Hyperpolarized 129Xe MRI for Monitoring Patients with Endobronchial Valve Interventions. Am J Respir Crit Care Med 2022; 205:e48-e50. [PMID: 35044897 DOI: 10.1164/rccm.202106-1395im] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
5
|
Hyperpolarized 129 Xe MRI of the rat brain with chemical shift saturation recovery and spiral-IDEAL readout. Magn Reson Med 2021; 87:1971-1979. [PMID: 34841605 DOI: 10.1002/mrm.29105] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 11/11/2021] [Accepted: 11/12/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE To demonstrate the feasibility of 129 Xe chemical shift saturation recovery (CSSR) combined with spiral-IDEAL imaging for simultaneous measurement of the time-course of red blood cell (RBC) and brain tissue signals in the rat brain. METHODS Images of both the RBC and brain tissue 129 Xe signals from the brains of five rats were obtained using interleaved spiral-IDEAL imaging following chemical shift saturation pulses applied at multiple CSSR delay times, τ. A linear fit of the signals to τ was used to calculate the slope of the signal for both RBC and brain tissue compartments on a voxel-by-voxel basis. Gas transfer was evaluated by measuring the ratio of the whole brain tissue-to-RBC signal intensities as a function of τ. To investigate the relationship between the CSSR images and gas transfer in the brain, the experiments were repeated during hypercapnic ventilation. RESULTS Hypercapnia, affected the ratio of the tissue-to-RBC signal intensity (p = 0.026), consistent with an increase in gas transfer. CONCLUSION CSSR with spiral-IDEAL imaging is feasible for acquisition of 129 Xe RBC and brain tissue time-course images in the rat brain. Differences in the time-course of the signal intensity ratios are consistent with gas transfer changes expected under hypercapnic conditions.
Collapse
|
6
|
Abstract
OBJECTIVES It is not known how lung injury progression during mechanical ventilation modifies pulmonary responses to prone positioning. We compared the effects of prone positioning on regional lung aeration in late versus early stages of lung injury. DESIGN Prospective, longitudinal imaging study. SETTING Research imaging facility at The University of Pennsylvania (Philadelphia, PA) and Medical and Surgical ICUs at Massachusetts General Hospital (Boston, MA). SUBJECTS Anesthetized swine and patients with acute respiratory distress syndrome (acute respiratory distress syndrome). INTERVENTIONS Lung injury was induced by bronchial hydrochloric acid (3.5 mL/kg) in 10 ventilated Yorkshire pigs and worsened by supine nonprotective ventilation for 24 hours. Whole-lung CT was performed 2 hours after hydrochloric acid (Day 1) in both prone and supine positions and repeated at 24 hours (Day 2). Prone and supine images were registered (superimposed) in pairs to measure the effects of positioning on the aeration of each tissue unit. Two patients with early acute respiratory distress syndrome were compared with two patients with late acute respiratory distress syndrome, using electrical impedance tomography to measure the effects of body position on regional lung mechanics. MEASUREMENTS AND MAIN RESULTS Gas exchange and respiratory mechanics worsened over 24 hours, indicating lung injury progression. On Day 1, prone positioning reinflated 18.9% ± 5.2% of lung mass in the posterior lung regions. On Day 2, position-associated dorsal reinflation was reduced to 7.3% ± 1.5% (p < 0.05 vs Day 1). Prone positioning decreased aeration in the anterior lungs on both days. Although prone positioning improved posterior lung compliance in the early acute respiratory distress syndrome patients, it had no effect in late acute respiratory distress syndrome subjects. CONCLUSIONS The effects of prone positioning on lung aeration may depend on the stage of lung injury and duration of prior ventilation; this may limit the clinical efficacy of this treatment if applied late.
Collapse
|
7
|
Ventilation heterogeneity imaged by multibreath wash-ins of hyperpolarized 3 He and 129 Xe in healthy rabbits. J Physiol 2021; 599:4197-4223. [PMID: 34256417 DOI: 10.1113/jp281584] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/30/2021] [Indexed: 12/20/2022] Open
Abstract
KEY POINTS Multibreath imaging to estimate regional gas mixing efficiency is superior to intensity-based single-breath ventilation markers, as it is capable of revealing minute but essential measures of ventilation heterogeneity which may be sensitive to subclinical alterations in the early stages of both obstructive and restrictive respiratory disorders. Large-scale convective stratification of ventilation in central-to-peripheral directions is the dominant feature of observed ventilation heterogeneity when imaging a heavy/less diffusive xenon gas mixture; smaller-scale patchiness, probably originating from asymmetric lung function at bronchial airway branching due to the interaction of convective and diffusive flows, is the dominant feature when imaging a lighter/more diffusive helium gas mixture. Since detecting low regional ventilation is crucial for characterizing diseased lungs, our results suggest that dilution with natural abundance helium and imaging at higher lung volumes seem advisable when imaging with hyperpolarized 129 Xe; this will allow the imaging gas to reach slow-filling and/or non-dependent lung regions, which might otherwise be impossible to distinguish from total ventilation shunt regions. The ability to differentiate these regions from those of total shunt is worse with typical single-breath imaging techniques. ABSTRACT The mixing of freshly inhaled gas with gas already present in the lung can be directly assessed with heretofore unachievable precision via magnetic resonance imaging of signal build-up resulting from multiple wash-ins of a hyperpolarized (HP) gas. Here, we used normoxic HP 3 He and 129 Xe mixtures to study regional ventilation at different spatial scales in five healthy mechanically ventilated supine rabbits at two different inspired volumes. To decouple the respective effects of density and diffusion rates on ventilation heterogeneity, two additional studies were performed: one in which 3 He was diluted with an equal fraction of natural abundance xenon, and one in which 129 Xe was diluted with an equal fraction of 4 He. We observed systematic differences in the spatial scale of specific ventilation heterogeneity between HP 3 He and 129 Xe. We found that large-scale, central-to-peripheral convective ventilation inhomogeneity is the dominant cause of observed heterogeneity when breathing a normoxic xenon gas mixture. In contrast, small-scale ventilation heterogeneity in the form of patchiness, probably originating from asymmetric lung function at bronchial airway branching due to interactions between convective and diffusive flows, is the dominant feature when breathing a normoxic helium gas mixture, for which the critical zone occurs more proximally and at an imageable spatial scale. We also showed that the existence of particular underventilated non-dependent lung regions when breathing a heavy gas mixture is the result of the density of that mixture - rather than, for example, its diffusion rate or viscosity. Finally, we showed that gravity-dependent ventilation heterogeneity becomes substantially more uniform at higher inspired volumes for xenon gas mixtures compared to helium mixtures.
Collapse
|
8
|
Measuring pulmonary gas exchange using compartment-selective xenon-polarization transfer contrast (XTC) MRI. Magn Reson Med 2020; 85:2709-2722. [PMID: 33283943 DOI: 10.1002/mrm.28626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 11/06/2020] [Accepted: 11/09/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE To demonstrate the feasibility of generating red blood cell (RBC) and tissue/plasma (TP)-specific gas-phase (GP) depolarization maps using xenon-polarization transfer contrast (XTC) MR imaging. METHODS Imaging was performed in three healthy subjects, an asymptomatic smoker, and a chronic obstructive pulmonary disease (COPD) patient. Single-breath XTC data were acquired through a series of three GP images using a 2D multi-slice GRE during a 12 s breath-hold. A series of 8 ms Gaussian inversion pulses spaced 30 ms apart were applied in-between the images to quantify the exchange between the GP and dissolved-phase (DP) compartments. Inversion pulses were either centered on-resonance to generate contrast, or off-resonance to correct for other sources of signal loss. For an alternative scheme, inversions of both RBC and TP resonances were inserted in lieu of off-resonance pulses. Finally, this technique was extended to a multi-breath protocol consistent with tidal breathing, involving 30 consecutive acquisitions. RESULTS Inversion pulses shifted off-resonance by 20 ppm to mimic the distance between the RBC and TP resonances demonstrated selectivity, and initial GP depolarization maps illustrated stark magnitude and distribution differences between healthy and diseased subjects that were consistent with traditional approaches. CONCLUSION The proposed DP-compartment selective XTC MRI technique provides information on gas exchange between all three detectable states of xenon in the lungs and is sufficiently sensitive to indicate differences in lung function between the study subjects. Investigated extensions of this approach to imaging schemes that either minimize breath-hold duration or the overall number of breath-holds open avenues for future research to improve measurement accuracy and patient comfort.
Collapse
|
9
|
Pulmonary pyruvate metabolism as an index of inflammation and injury in a rat model of acute respiratory distress syndrome. NMR IN BIOMEDICINE 2020; 33:e4380. [PMID: 32681670 DOI: 10.1002/nbm.4380] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 06/15/2020] [Accepted: 06/29/2020] [Indexed: 06/11/2023]
Abstract
Increased pulmonary lactate production is correlated with severity of lung injury and outcome in acute respiratory distress syndrome (ARDS) patients. This study was conducted to investigate the relative contributions of inflammation and hypoxia to the lung's metabolic shift to glycolysis in an experimental animal model of ARDS using hyperpolarized (HP) 13 C MRI. Fifty-three intubated and mechanically ventilated male rats were imaged using HP 13 C MRI before, and 1, 2.5 and 4 hours after saline (sham) or hydrochloric acid (HCl; 0.5 ml/kg) instillation in the trachea, followed by protective and nonprotective mechanical ventilation (HCl-PEEP and HCl-ZEEP) or the start of moderate or severe hypoxia (Hyp90 and Hyp75 groups). Pulmonary and cardiac HP lactate-to-pyruvate ratios were compared among groups for different time points. Postmortem histology and immunofluorescence were used to assess lung injury severity and quantify the expression of innate inflammatory markers and local tissue hypoxia. HP pulmonary lactate-to-pyruvate ratio progressively increased in rats with lung injury and moderate hypoxia (HCl-ZEEP), with no significant change in pulmonary lactate-to-pyruvate ratio in noninjured but moderately hypoxic rats (Hyp90). Pulmonary lactate-to-pyruvate ratio was elevated in otherwise healthy lung tissue only in severe systemic hypoxia (Hyp75 group). ex vivo histological and immunopathological assessment further confirmed the link between elevated glycolysis and the recruitment into and presence of activated neutrophils in injured lungs. HP lactate-to-pyruvate ratio is elevated in injured lungs predominantly as a result of increased glycolysis in activated inflammatory cells, but can also increase due to severe inflammation-induced hypoxia.
Collapse
|
10
|
Hyperpolarized Metabolic Imaging Detects Latent Hepatocellular Carcinoma Domains Surviving Locoregional Therapy. Hepatology 2020; 72:140-154. [PMID: 31553806 PMCID: PMC7307779 DOI: 10.1002/hep.30970] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 09/08/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND AIMS Advances in cancer treatment have improved survival; however, local recurrence and metastatic disease-the principal causes of cancer mortality-have limited the ability to achieve durable remissions. Local recurrences arise from latent tumor cells that survive therapy and are often not detectable by conventional clinical imaging techniques. Local recurrence after transarterial embolization (TAE) of hepatocellular carcinoma (HCC) provides a compelling clinical correlate of this phenomenon. In response to TAE-induced ischemia, HCC cells adapt their growth program to effect a latent phenotype that precedes local recurrence. APPROACH AND RESULTS In this study, we characterized and leveraged the metabolic reprogramming demonstrated by latent HCC cells in response to TAE-induced ischemia to enable their detection in vivo using dynamic nuclear polarization (DNP) magnetic resonance spectroscopic imaging (MRSI) of 13 carbon-labeled substrates. Under TAE-induced ischemia, latent HCC cells demonstrated reduced metabolism and developed a dependence on glycolytic flux to lactate. Despite the hypometabolic state of these cells, DNP-MRSI of 1-13 C-pyruvate and its downstream metabolites, 1-13 C-lactate and 1-13 C-alanine, predicted histological viability. CONCLUSIONS These studies provide a paradigm for imaging latent, treatment-refractory cancer cells, suggesting that DNP-MRSI provides a technology for this application.
Collapse
|
11
|
Investigating biases in the measurement of apparent alveolar septal wall thickness with hyperpolarized 129Xe MRI. Magn Reson Med 2020; 84:3027-3039. [PMID: 32557808 DOI: 10.1002/mrm.28329] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 04/03/2020] [Accepted: 04/29/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To investigate biases in the measurement of apparent alveolar septal wall thickness (SWT) with hyperpolarized xenon-129 (HXe) as a function of acquisition parameters. METHODS The HXe MRI scans with simultaneous gas-phase and dissolved-phase excitation were performed using 1-dimensional projection scans in mechanically ventilated rabbits. The dissolved-phase magnetization was periodically saturated, and the dissolved-phase xenon uptake dynamics were measured at end inspiration and end expiration with temporal resolutions up to 10 ms using a Look-Locker-type acquisition. The apparent alveolar septal wall thickness was extracted by fitting the signal to a theoretical model, and the findings were compared with those from the more commonly use chemical shift saturation recovery MRI spectroscopy technique with several different delay time arrangements. RESULTS It was found that repeated application of RF saturation pulses in chemical shift saturation recovery acquisitions caused exchange-dependent gas-phase saturation that heavily biased the derived SWT value. When this bias was reduced by our proposed method, the SWT dependence on lung inflation disappeared due to an inherent insensitivity of HXe dissolved-phase MRI to thin alveolar structures with very short T 2 ∗ . Furthermore, perfusion-based macroscopic gas transport processes were demonstrated to cause increasing apparent SWTs with TE (2.5 μm/ms at end expiration) and a lung periphery-to-center SWT gradient. CONCLUSION The apparent SWT measured with HXe MRI was found to be heavily dependent on the acquisition parameters. A method is proposed that can minimize this measurement bias, add limited spatial resolution, and reduce measurement time to a degree that free-breathing studies are feasible.
Collapse
|
12
|
Computational pipeline for estimation of small-molecule T1 relaxation times. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 314:106733. [PMID: 32339979 PMCID: PMC8826363 DOI: 10.1016/j.jmr.2020.106733] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 04/09/2020] [Accepted: 04/12/2020] [Indexed: 06/11/2023]
Abstract
Molecular imaging of biologic molecules and cellular processes is increasingly accessible through hyperpolarization of chemically-equivalent stable isotopes, most commonly 13C. However, many molecules are poor candidates for imaging due to their biophysical properties, particularly short spin-lattice relaxation times (T1). The inability to consistently predict the T1 from molecular structure, lack of experimental data for many biologically-relevant molecules and the high cost of developing probes can limit the development of hyperpolarized probes. We describe an in silico pipeline for modeling the estimated T1 of molecules of interest in order to address this deficiency. Applying a hybrid approach that incorporates molecular dynamics as well as quantum mechanics, this pipeline estimated T1 values that closely matched empirically determined values providing proof-of-principle that this approach may be used to facilitate MR probe development.
Collapse
|
13
|
Detection of lung transplant rejection in a rat model using hyperpolarized [1- 13 C] pyruvate-based metabolic imaging. NMR IN BIOMEDICINE 2019; 32:e4107. [PMID: 31112351 PMCID: PMC6620127 DOI: 10.1002/nbm.4107] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 03/19/2019] [Accepted: 03/29/2019] [Indexed: 05/03/2023]
Abstract
The current standard for noninvasive imaging of acute rejection consists of X-ray/CT, which derive their contrast from changes in ventilation, inflammation and edema, as well as remodeling during rejection. We propose the use of hyperpolarized [1-13 C] pyruvate MRI-which provides real-time metabolic assessment of tissue-as an early biomarker for tissue rejection. In this preliminary study, we used μCT-derived parameters and HP 13 C MR-derived biomarkers to predict rejection in an orthotopic left lung transplant model in both allogeneic and syngeneic rats. On day 3, the normalized lung density-a parameter that accounts for both lung volume (mL) and density (HU)-was -0.335 (CI: -0.598, -0.073) and - 0.473 (CI: -0.726, -0.220) for the allograft and isograft, respectively (not significant, 0.40). The lactate-to-pyruvate ratios-derived from the HP 13 C MRI-for the allograft and isograft were 0.200 (CI: 0.161, 0.240) and 0.114 (CI: 0.074, 0.153), respectively (significant, 0.020). Both techniques showed tissue rejection on day 7. A separate sub-study revealed CD8+ cells as the primary source of the lactate-to-pyruvate signal. Our study suggests that hyperpolarized (HP) [1-13 C] pyruvate MRI is a promising early biomarker for tissue rejection that provides metabolic assessment in real time based on changes in cellularity and metabolism of lung tissue and the infiltrating inflammatory cells, and may be able to predict tissue rejection earlier than X-ray/CT.
Collapse
|
14
|
Measurement of Regional 2D Gas Transport Efficiency in Rabbit Lung Using Hyperpolarized 129Xe MRI. Sci Rep 2019; 9:2413. [PMID: 30787357 PMCID: PMC6382756 DOI: 10.1038/s41598-019-38942-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/11/2018] [Indexed: 01/25/2023] Open
Abstract
While hyperpolarized xenon-129 (HXe) MRI offers a wide array of tools for assessing functional aspects of the lung, existing techniques provide only limited quantitative information about the impact of an observed pathology on overall lung function. By selectively destroying the alveolar HXe gas phase magnetization in a volume of interest and monitoring the subsequent decrease in the signal from xenon dissolved in the blood inside the left ventricle of the heart, it is possible to directly measure the contribution of that saturated lung volume to the gas transport capacity of the entire lung. In mechanically ventilated rabbits, we found that both xenon gas transport and transport efficiency exhibited a gravitation-induced anterior-to-posterior gradient that disappeared or reversed direction, respectively, when the animal was turned from supine to prone position. Further, posterior ventilation defects secondary to acute lung injury could be re-inflated by applying positive end expiratory pressure, although at the expense of decreased gas transport efficiency in the anterior volumes. These findings suggest that our technique might prove highly valuable for evaluating lung transplants and lung resections, and could improve our understanding of optimal mechanical ventilator settings in acute lung injury.
Collapse
|
15
|
Assessment of flip angle-TR equivalence for standardized dissolved-phase imaging of the lung with hyperpolarized 129Xe MRI. Magn Reson Med 2018; 81:1784-1794. [PMID: 30346083 DOI: 10.1002/mrm.27538] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 08/20/2018] [Accepted: 08/27/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE To investigate the feasibility of describing the impact of any flip angle-TR combination on the resulting distribution of the hyperpolarized xenon-129 (HXe) dissolved-phase magnetization in the chest using a single virtual parameter, TR90°,equiv . METHODS HXe MRI scans with simultaneous gas- (GP) and dissolved-phase (DP) excitation were performed using 2D projection scans in mechanically ventilated rabbits. Measurements with DP flip angles ranging from 6-90° and TRs ranging from 8.3-500 ms were conducted. DP maps based on acquisitions of similar radio frequency pulse-induced relaxation rates were compared. RESULTS The observed distribution of the DP magnetization was strongly affected by acquisition flip angle and TR. However, for flip angles up to 60°, measurements with the same radio frequency pulse-induced relaxation rates, resulted in very similar DP images despite the presence of significant macroscopic gas transport processes. For flip angles approaching 90°, the downstream signal component decreased noticeably relative to acquisitions with lower flip angles. Nevertheless, the total DP signal continued to follow an empirically verified conversion equation over the entire investigated parameter range, which yields the equivalent TR of a hypothetical 90° measurement for any experimental flip angle-TR combination. CONCLUSION We have introduced a method for converting the flip angle and TR of a given HXe DP measurement to a standardized metric based on the virtual quantity, TR90°,equiv , using their equivalent RF relaxation rates. This conversion permits the comparison of measurements obtained with different pulse sequence types or by different research groups using various acquisition parameters.
Collapse
|
16
|
Unstable Inflation Causing Injury. Insight from Prone Position and Paired Computed Tomography Scans. Am J Respir Crit Care Med 2018; 198:197-207. [PMID: 29420904 PMCID: PMC6058981 DOI: 10.1164/rccm.201708-1728oc] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 02/08/2018] [Indexed: 01/16/2023] Open
Abstract
RATIONALE It remains unclear how prone positioning improves survival in acute respiratory distress syndrome. Using serial computed tomography (CT), we previously reported that "unstable" inflation (i.e., partial aeration with large tidal density swings, indicating increased local strain) is associated with injury progression. OBJECTIVES We prospectively tested whether prone position contains the early propagation of experimental lung injury by stabilizing inflation. METHODS Injury was induced by tracheal hydrochloric acid in rats; after randomization to supine or prone position, injurious ventilation was commenced using high tidal volume and low positive end-expiratory pressure. Paired end-inspiratory (EI) and end-expiratory (EE) CT scans were acquired at baseline and hourly up to 3 hours. Each sequential pair (EI, EE) of CT images was superimposed in parametric response maps to analyze inflation. Unstable inflation was then measured in each voxel in both dependent and nondependent lung. In addition, five pigs were imaged (EI and EE) prone versus supine, before and (1 hour) after hydrochloric acid aspiration. MEASUREMENTS AND MAIN RESULTS In rats, prone position limited lung injury propagation and increased survival (11/12 vs. 7/12 supine; P = 0.01). EI-EE densities, respiratory mechanics, and blood gases deteriorated more in supine versus prone rats. At baseline, more voxels with unstable inflation occurred in dependent versus nondependent regions when supine (41 ± 6% vs. 18 ± 7%; P < 0.01) but not when prone. In supine pigs, unstable inflation predominated in dorsal regions and was attenuated by prone positioning. CONCLUSIONS Prone position limits the radiologic progression of early lung injury. Minimizing unstable inflation in this setting may alleviate the burden of acute respiratory distress syndrome.
Collapse
|
17
|
Assessment of Pulmonary Gas Transport in Rabbits Using Hyperpolarized Xenon-129 Magnetic Resonance Imaging. Sci Rep 2018; 8:7310. [PMID: 29743565 PMCID: PMC5943289 DOI: 10.1038/s41598-018-25713-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 04/09/2018] [Indexed: 02/07/2023] Open
Abstract
Many forms of lung disease manifest themselves as pathological changes in the transport of gas to the circulatory system, yet the difficulty of imaging this process remains a central obstacle to the comprehensive diagnosis of lung disorders. Using hyperpolarized xenon-129 as a surrogate marker for oxygen, we derived the temporal dynamics of gas transport from the ratio of two lung images obtained with different timing parameters. Additionally, by monitoring changes in the total hyperpolarized xenon signal intensity in the left side of the heart induced by depletion of xenon signal in the alveolar airspaces of interest, we quantified the contributions of selected lung volumes to the total pulmonary gas transport. In a rabbit model, we found that it takes at least 200 ms for xenon gas to enter the lung tissue and travel the distance from the airspaces to the heart. Additionally, our method shows that both lungs contribute fairly equally to the gas transport in healthy rabbits, but that this ratio changes in a rabbit model of acid aspiration. These results suggest that hyperpolarized xenon-129 MRI may improve our ability to measure pulmonary gas transport and detect associated pathological changes.
Collapse
|
18
|
Rapid assessment of pulmonary gas transport with hyperpolarized 129Xe MRI using a 3D radial double golden-means acquisition with variable flip angles. Magn Reson Med 2018; 80:2439-2448. [PMID: 29682792 DOI: 10.1002/mrm.27217] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 03/20/2018] [Accepted: 03/24/2018] [Indexed: 12/15/2022]
Abstract
PURPOSE To demonstrate the feasibility of using a 3D radial double golden-means acquisition with variable flip angles to monitor pulmonary gas transport in a single breath hold with hyperpolarized xenon-129 MRI. METHODS Hyperpolarized xenon-129 MRI scans with interleaved gas-phase and dissolved-phase excitations were performed using a 3D radial double golden-means acquisition in mechanically ventilated rabbits. The flip angle was either held fixed at 15 ° or 5 °, or it was varied linearly in ascending or descending order between 5 ° and 15 ° over a sampling interval of 1000 spokes. Dissolved-phase and gas-phase images were reconstructed at high resolution (32 × 32 × 32 matrix size) using all 1000 spokes, or at low resolution (22 × 22 × 22 matrix size) using 400 spokes at a time in a sliding-window fashion. Based on these sliding-window images, relative change maps were obtained using the highest mean flip angle as the reference, and aggregated pixel-based changes were tracked. RESULTS Although the signal intensities in the dissolve-phase maps were mostly constant in the fixed flip-angle acquisitions, they varied significantly as a function of average flip angle in the variable flip-angle acquisitions. The latter trend reflects the underlying changes in observed dissolve-phase magnetization distribution due to pulmonary gas uptake and transport. CONCLUSION 3D radial double golden-means acquisitions with variable flip angles provide a robust means for rapidly assessing lung function during a single breath hold, thereby constituting a particularly valuable tool for imaging uncooperative or pediatric patient populations.
Collapse
|
19
|
Lung Metabolism and Inflammation during Mechanical Ventilation; An Imaging Approach. Sci Rep 2018; 8:3525. [PMID: 29476083 PMCID: PMC5824838 DOI: 10.1038/s41598-018-21901-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 02/13/2018] [Indexed: 12/20/2022] Open
Abstract
Acute respiratory distress syndrome (ARDS) is a major cause of mortality in critically ill patients. Patients are currently managed by protective ventilation and alveolar recruitment using positive-end expiratory pressure (PEEP). However, the PEEP's effect on both pulmonary metabolism and regional inflammation is poorly understood. Here, we demonstrate the effect of PEEP on pulmonary anaerobic metabolism in mechanically ventilated injured rats, using hyperpolarized carbon-13 imaging. Pulmonary lactate-to-pyruvate ratio was measured in 21 rats; 14 rats received intratracheal instillation of hydrochloric-acid, while 7 rats received sham saline. 1 hour after acid/saline instillation, PEEP was lowered to 0 cmH2O in 7 injured rats (ZEEP group) and in all sham rats; PEEP was continued in the remaining 7 injured rats (PEEP group). Pulmonary compliance, oxygen saturation, histological injury scores, ICAM-1 expression and myeloperoxidase expression were measured. Lactate-to-pyruvate ratio progressively increased in the dependent lung during mechanical ventilation at ZEEP (p < 0.001), but remained unchanged in PEEP and sham rats. Lactate-to-pyruvate ratio was correlated with hyaline membrane deposition (r = 0.612), edema severity (r = 0.663), ICAM-1 (r = 0.782) and myeloperoxidase expressions (r = 0.817). Anaerobic pulmonary metabolism increases during lung injury progression and is contained by PEEP. Pulmonary lactate-to-pyruvate ratio may indicate in-vivo neutrophil activity due to atelectasis.
Collapse
|
20
|
A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized 3 He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping. Magn Reson Med 2017; 78:611-624. [PMID: 27734519 PMCID: PMC5391315 DOI: 10.1002/mrm.26401] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 08/03/2016] [Accepted: 08/08/2016] [Indexed: 01/06/2023]
Abstract
PURPOSE To present a method for simultaneous acquisition of alveolar oxygen tension (PA O2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the PA O2 and SV maps to produce a map of oxygen uptake (R). METHOD An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, PA O2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts. RESULTS The overall whole lung ADC, SV, PA O2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, PA O2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation. CONCLUSION High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78:611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
21
|
Abstract
Background Uncertain prediction of outcome in acute respiratory distress syndrome (ARDS) impedes individual patient management and clinical trial design. Objectives To develop a radiological metric of injurious inflation derived from matched inspiratory and expiratory CT scans, calibrate it in a model of experimental lung injury, and test it in patients with ARDS. Methods 73 anaesthetised rats (acid aspiration model) were ventilated (protective or non-protective) for up to 4 hours to generate a spectrum of lung injury. CT was performed (inspiratory and expiratory) at baseline each hour, paired inspiratory and expiratory images were superimposed and voxels tracked in sequential scans. In nine patients with ARDS, paired inspiratory and expiratory CT scans from the first intensive care unit week were analysed. Results In experimental studies, regions of lung with unstable inflation (ie, partial or reversible airspace filling reflecting local strain) were the areas in which subsequent progression of injury was greatest in terms of progressive infiltrates (R=0.77) and impaired compliance (R=0.67, p<0.01). In patients with ARDS, a threshold fraction of tissue with unstable inflation was apparent: >28% in all patients who died and ≤28% in all who survived, whereas segregation of survivors versus non-survivors was not possible based on oxygenation or lung mechanics. Conclusions A single set of superimposed inspiratory–expiratory CT scans may predict progression of lung injury and outcome in ARDS; if these preliminary results are validated, this could facilitate clinical trial recruitment and individualised care.
Collapse
|
22
|
Hyperpolarized gas diffusion MRI of biphasic lung inflation in short- and long-term emphysema models. Am J Physiol Lung Cell Mol Physiol 2017; 313:L305-L312. [PMID: 28473321 DOI: 10.1152/ajplung.00048.2017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 04/28/2017] [Accepted: 04/29/2017] [Indexed: 11/22/2022] Open
Abstract
During lung inflation, airspace dimensions are affected nonlinearly by both alveolar expansion and recruitment, potentially confounding the identification of emphysematous lung by hyperpolarized helium-3 diffusion magnetic resonance imaging (HP MRI). This study aimed to characterize lung inflation over a broad range of inflation volume and pressure values in two different models of emphysema, as well as in normal lungs. Elastase-treated rats (n = 7) and healthy controls (n = 7) were imaged with HP MRI. Gradual inflation was achieved by incremental changes to both inflation volume and airway pressure. The apparent diffusion coefficient (ADC) was measured at each level of inflation and fitted to the corresponding airway pressures as the second-order response equation, with minimizing residue (χ2 < 0.001). A biphasic ADC response was detected, with an initial ADC increase followed by a decrease at airway pressures >18 cmH2O. Discrimination between treated and control rats was optimal when airway pressure was intermediate (between 10 and 11 cmH2O). Similar findings were confirmed in mice following long-term exposure to cigarette smoke, where optimal discrimination between treated and healthy mice occurred at a similar airway pressure as in the rats. We subsequently explored the evolution of ADC measured at the intermediate inflation level in mice after prolonged smoke exposure and found a significant increase (P < 0.01) in ADC over time. Our results demonstrate that measuring ADC at intermediate inflation enhances the distinction between healthy and diseased lungs, thereby establishing a model that may improve the diagnostic accuracy of future HP gas diffusion studies.
Collapse
|
23
|
The use of hyperpolarized carbon-13 magnetic resonance for molecular imaging. Adv Drug Deliv Rev 2017; 113:3-23. [PMID: 27599979 PMCID: PMC5783573 DOI: 10.1016/j.addr.2016.08.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 08/25/2016] [Accepted: 08/27/2016] [Indexed: 02/06/2023]
Abstract
Until recently, molecular imaging using magnetic resonance (MR) has been limited by the modality's low sensitivity, especially with non-proton nuclei. The advent of hyperpolarized (HP) MR overcomes this limitation by substantially enhancing the signal of certain biologically important probes through a process known as external nuclear polarization, enabling real-time assessment of tissue function and metabolism. The metabolic information obtained by HP MR imaging holds significant promise in the clinic, where it could play a critical role in disease diagnosis and therapeutic monitoring. This review will provide a comprehensive overview of the developments made in the field of hyperpolarized MR, including advancements in polarization techniques and delivery, probe development, pulse sequence optimization, characterization of healthy and diseased tissues, and the steps made towards clinical translation.
Collapse
|
24
|
Quantifying reaction kinetics of the non-enzymatic decarboxylation of pyruvate and production of peroxymonocarbonate with hyperpolarized13C-NMR. Phys Chem Chem Phys 2017; 19:19316-19325. [DOI: 10.1039/c7cp02041d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Hyperpolarized13C-NMR is used to study the reaction mechanism and kinetics for non-enzymatic decarboxylation of pyruvate and formation of peroxymonocarbonate.
Collapse
|
25
|
In vivo pH mapping of injured lungs using hyperpolarized [1- 13 C]pyruvate. Magn Reson Med 2016; 78:1121-1130. [PMID: 27714832 DOI: 10.1002/mrm.26473] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Revised: 08/26/2016] [Accepted: 08/29/2016] [Indexed: 12/21/2022]
Abstract
PURPOSE To optimize the production of hyperpolarized 13 C-bicarbonate from the decarboxylation of hyperpolarized [1-13 C]pyruvate and use it to image pH in the lungs and heart of rats with acute lung injury. METHODS Two forms of catalysis are compared calorimetrically to maximize the rate of decarboxylation and rapidly produce hyperpolarized bicarbonate from pyruvate while minimizing signal loss. Rats are injured using an acute lung injury model combining ventilator-induced lung injury and acid aspiration. Carbon images are obtained from both healthy (n = 4) and injured (n = 4) rats using a slice-selective chemical shift imaging sequence with low flip angle. pH is calculated from the relative HCO3- and CO2 signals using the Henderson-Hasselbalch equation. RESULTS It is demonstrated that base catalysis is more effective than metal-ion catalysis for this decarboxylation reaction. Bicarbonate polarizations up to 17.2% are achieved using the base-catalyzed reaction. A mean pH difference between lung and heart of 0.14 pH units is measured in the acute lung injury model. A significant pH difference between injured and uninjured lungs is also observed. CONCLUSION It is demonstrated that hyperpolarized 13 C-bicarbonate can be efficiently produced from the base-catalyzed decarboxylation of pyruvate. This method is used to obtain the first regional pH image of the lungs and heart of an animal. Magn Reson Med 78:1121-1130, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
26
|
Mild loss of lung aeration augments stretch in healthy lung regions. J Appl Physiol (1985) 2015; 120:444-54. [PMID: 26662053 DOI: 10.1152/japplphysiol.00734.2015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Accepted: 12/07/2015] [Indexed: 11/22/2022] Open
Abstract
Inspiratory stretch by mechanical ventilation worsens lung injury. However, it is not clear whether and how the ventilator damages lungs in the absence of preexisting injury. We hypothesized that subtle loss of lung aeration during general anesthesia regionally augments ventilation and distension of ventilated air spaces. In eight supine anesthetized and intubated rats, hyperpolarized gas MRI was performed after a recruitment maneuver following 1 h of volume-controlled ventilation with zero positive end-expiratory pressure (ZEEP), FiO2 0.5, and tidal volume 10 ml/kg, and after a second recruitment maneuver. Regional fractional ventilation (FV), apparent diffusion coefficient (ADC) of (3)He (a measurement of ventilated peripheral air space dimensions), and gas volume were measured in lung quadrants of ventral and dorsal regions of the lungs. In six additional rats, computed tomography (CT) images were obtained at each time point. Ventilation with ZEEP decreased total lung gas volume and increased both FV and ADC in all studied regions. Increases in FV were more evident in the dorsal slices. In each lung quadrant, higher ADC was predicted by lower gas volume and by increased mean values (and heterogeneity) of FV distribution. CT scans documented 10% loss of whole-lung aeration and increased density in the dorsal lung, but no macroscopic atelectasis. Loss of pulmonary gas at ZEEP increased fractional ventilation and inspiratory dimensions of ventilated peripheral air spaces. Such regional changes could help explain a propensity for mechanical ventilation to contribute to lung injury in previously uninjured lungs.
Collapse
|
27
|
Ascorbic acid prolongs the viability and stability of isolated perfused lungs: A mechanistic study using 31P and hyperpolarized 13C nuclear magnetic resonance. Free Radic Biol Med 2015; 89:62-71. [PMID: 26165188 DOI: 10.1016/j.freeradbiomed.2015.06.042] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 06/19/2015] [Accepted: 06/28/2015] [Indexed: 01/10/2023]
Abstract
Ex vivo lung perfusion (EVLP) has recently shown promise as a means of more accurately gauging the health of lung grafts and improving graft performance post-transplant. However, reperfusion of ischemic lung promotes the depletion of high-energy compounds and a progressive loss of normal mitochondrial function, and it remains unclear how and to what extent the EVLP approach contributes to this metabolic decline. Although ascorbate has been used to mitigate the effects of ischemia-reperfusion injury, the nature of its effects during EVLP are also not clear. To address these uncertainties, this study monitored the energy status of lungs during EVLP and after the administration of ascorbate using (31)P and hyperpolarized (13)C NMR (nuclear magnetic resonance). Our experiments demonstrated that the oxidative phosphorylation capacity and pyruvate dehydrogenase flux of lungs decline during ex vivo perfusion. The addition of ascorbate to the perfusate prolonged lung viability by 80% and increased the hyperpolarized (13)C bicarbonate signal by a factor of 2.7. The effect of ascorbate is apparently due not to its antioxidant quality but rather to its ability to energize cellular respiration given that it increased the lung's energy charge significantly, whereas other antioxidants (glutathione and α-lipoic acid) did not alter energy metabolism. During ascorbate administration, inhibition of mitochondrial complex I with rotenone depressed energy charge and shifted the metabolic state of the lung toward glycolysis; reenergizing the electron transport chain with TMPD (N,N,N',N'-tetramethyl-p-phenylenediamine) recovered metabolic activity. This indicates that ascorbate slows the decline of the ex vivo perfused lung's mitochondrial activity through an independent interaction with the electron transport chain complexes.
Collapse
|
28
|
Multibreath alveolar oxygen tension imaging. Magn Reson Med 2015; 76:1092-101. [PMID: 26467179 DOI: 10.1002/mrm.26001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Revised: 09/02/2015] [Accepted: 09/04/2015] [Indexed: 12/23/2022]
Abstract
PURPOSE This study tested the ability of a multibreath hyperpolarized HP (3) He MRI protocol to increase the accuracy of regional alveolar oxygen tension (PA O2 ) measurements by lessening the influence of gas-flow artifacts. Conventional single-breath PA O2 measurement has been susceptible to error induced by intervoxel gas flow, particularly when used to study subjects with moderate-to-severe chronic obstructive pulmonary disease (COPD). METHODS Both single-breath and multibreath PA O2 imaging schemes were implemented in seven human subjects (one healthy, three asymptomatic smokers, and three COPD). The number and location of voxels with nonphysiologic PA O2 values generated by intervoxel gas flow were compared between the two protocols. RESULTS The multibreath scheme resulted in a significantly lower total percentage of nonphysiologic PA O2 values (6.0%) than the single-breath scheme (13.7%) (P = 0.006). PA O2 maps showed several patterns of gas-flow artifacts that were present in the single-breath protocol but mitigated by the multibreath approach. Multibreath imaging also allowed for the analysis of slow-filling areas that presented no signal after a single breath. CONCLUSION A multibreath approach enhances the accuracy and completeness of noninvasive PA O2 measurement by significantly lessening the proportion of nonphysiologic values generated by intervoxel gas flow. Magn Reson Med 76:1092-1101, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
|
29
|
Real-time metabolic imaging of tae-induced alterations in tumor metabolism using dynamic nuclear polarization carbon-13 magnetic resonance spectroscopy in vivo. J Vasc Interv Radiol 2015. [DOI: 10.1016/j.jvir.2014.12.195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
30
|
Hyperpolarized gas diffusion MRI for the study of atelectasis and acute respiratory distress syndrome. NMR IN BIOMEDICINE 2014; 27:1468-78. [PMID: 24920074 PMCID: PMC4232982 DOI: 10.1002/nbm.3136] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 04/03/2014] [Accepted: 04/21/2014] [Indexed: 06/03/2023]
Abstract
Considerable uncertainty remains about the best ventilator strategies for the mitigation of atelectasis and associated airspace stretch in patients with acute respiratory distress syndrome (ARDS). In addition to several immediate physiological effects, atelectasis increases the risk of ventilator-associated lung injury, which has been shown to significantly worsen ARDS outcomes. A number of lung imaging techniques have made substantial headway in clarifying the mechanisms of atelectasis. This paper reviews the contributions of computed tomography, positron emission tomography, and conventional MRI to understanding this phenomenon. In doing so, it also reveals several important shortcomings inherent to each of these approaches. Once these shortcomings have been made apparent, we describe how hyperpolarized (HP) gas MRI--a technique that is uniquely able to assess responses to mechanical ventilation and lung injury in peripheral airspaces--is poised to fill several of these knowledge gaps. The HP-MRI-derived apparent diffusion coefficient (ADC) quantifies the restriction of (3) He diffusion by peripheral airspaces, thereby obtaining pulmonary structural information at an extremely small scale. Lastly, this paper reports the results of a series of experiments that measured ADC in mechanically ventilated rats in order to investigate (i) the effect of atelectasis on ventilated airspaces, (ii) the relationship between positive end-expiratory pressure (PEEP), hysteresis, and the dimensions of peripheral airspaces, and (iii) the ability of PEEP and surfactant to reduce airspace dimensions after lung injury. An increase in ADC was found to be a marker of atelectasis-induced overdistension. With recruitment, higher airway pressures were shown to reduce stretch rather than worsen it. Moving forward, HP MRI has significant potential to shed further light on the atelectatic processes that occur during mechanical ventilation.
Collapse
|
31
|
The effect of exogenous substrate concentrations on true and apparent metabolism of hyperpolarized pyruvate in the isolated perfused lung. NMR IN BIOMEDICINE 2014; 27:1557-1570. [PMID: 25330438 PMCID: PMC4342041 DOI: 10.1002/nbm.3219] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 08/12/2014] [Accepted: 08/26/2014] [Indexed: 06/04/2023]
Abstract
Although relatively metabolically inactive, the lung has an important role in maintaining systemic glycolytic intermediate and cytosolic redox balance. Failure to perform this function appropriately may lead to lung disease progression, including systemic aspects of these disorders. In this study, we experimentally probe the response of the isolated, perfused organ to varying glycolytic intermediate (pyruvate and lactate) concentrations, and the effect on the apparent metabolism of hyperpolarized 1-(13)C pyruvate. Twenty-four separate conditions were studied, from sub-physiological to super-physiological concentrations of each metabolite. A three-compartment model is developed, which accurately matches the full range of experiments and includes a full account of evolution of agent concentration and polarization. The model is then refined using a series of approximations which are shown to be applicable to cases of physiological relevance, and which facilitate an intuitive understanding of the saturation and scaling behavior. Perturbations of the model assumptions are used to determine the sensitivity to input parameter estimates, and finally the model is used to examine the relationship between measurements accessible by NMR and the underlying physiological parameters of interest. Based on the observed scaling of lactate labeling with lactate and pyruvate concentrations, we conclude that the level of hyperpolarized lactate signal in the lung is primarily determined by the rate at which NAD(+) is reduced to NADH. Further, although weak dependences on other factors are predicted, the modeled NAD(+) reduction rate is largely governed by the intracellular lactate pool size. Conditions affecting the lactate pool can therefore be expected to display the highest contrast in hyperpolarized (13)C-pyruvate imaging. The work is intended to serve as a basis both to interpret the signal dynamics of hyperpolarized measurements in the normal lung and to understand the cause of alterations seen in a variety of disease and exposure models.
Collapse
|
32
|
Semiautomatic segmentation of longitudinal computed tomography images in a rat model of lung injury by surfactant depletion. J Appl Physiol (1985) 2014; 118:377-85. [PMID: 25640150 DOI: 10.1152/japplphysiol.00627.2014] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Quantitative analysis of computed tomography (CT) is essential to the study of acute lung injury. However, quantitative CT is made difficult by poor lung aeration, which complicates the critical step of image segmentation. To overcome this obstacle, this study sought to develop and validate a semiautomated, multilandmark, registration-based scheme for lung segmentation that is effective in conditions of poor aeration. Expiratory and inspiratory CT images were obtained in rats (n = 8) with surfactant depletion of incremental severity to mimic worsening aeration. Trained operators manually delineated the images to provide a comparative landmark. Semiautomatic segmentation originated from a single, previously segmented reference image obtained at healthy baseline. Deformable registration of the target images (after surfactant depletion) was performed using the symmetric diffeomorphic transformation model with B-spline regularization. Registration used multiple landmarks (i.e., rib cage, spine, and lung parenchyma) to minimize the effect of poor aeration. Then target images were automatically segmented by applying the calculated transformation function to the reference image contour. Semiautomatically and manually segmented contours proved to be highly similar in all aeration conditions, including those characterized by more severe surfactant depletion and expiration. The Dice similarity coefficient was over 0.9 in most conditions, confirming high agreement, irrespective of poor aeration. Furthermore, CT density-based measurements of gas volume, tissue mass, and lung aeration distribution were minimally affected by the method of segmentation. Moving forward, multilandmark registration has the potential to streamline quantitative CT analysis by enabling semiautomatic image segmentation of lungs with a broad range of injury severity.
Collapse
|
33
|
Metabolic spectroscopy of inflammation in a bleomycin-induced lung injury model using hyperpolarized 1-(13) C pyruvate. NMR IN BIOMEDICINE 2014; 27:939-47. [PMID: 24865640 PMCID: PMC4110199 DOI: 10.1002/nbm.3139] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Revised: 04/23/2014] [Accepted: 04/24/2014] [Indexed: 05/04/2023]
Abstract
Metabolic activity in the lung is known to change in response to external insults, inflammation, and cancer. We report measurements of metabolism in the isolated, perfused rat lung of healthy controls and in diseased lungs undergoing acute inflammation using hyperpolarized 1-(13) C-labeled pyruvate. The overall apparent activity of lactate dehydrogenase is shown to increase significantly (on average by a factor of 3.3) at the 7 day acute stage and to revert substantially to baseline at 21 days, while other markers indicating monocarboxylate uptake and transamination rate are unchanged. Elevated lung lactate signal levels correlate well with phosphodiester levels as determined with (31) P spectroscopy and with the presence of neutrophils as determined by histology, consistent with a relationship between intracellular lactate pool labeling and the density and type of inflammatory cells present. We discuss several alternate hypotheses, and conclude that the most probable source of the observed signal increase is direct uptake and metabolism of pyruvate by inflammatory cells and primarily neutrophils. This signal is seen in high contrast to the low baseline activity of the lung.
Collapse
|
34
|
Positive end-expiratory pressure increments during anesthesia in normal lung result in hysteresis and greater numbers of smaller aerated airspaces. Anesthesiology 2013; 119:1402-9. [PMID: 24025616 PMCID: PMC3987989 DOI: 10.1097/aln.0b013e3182a9b0c1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Although it is recognized that pulmonary hysteresis can influence the effects of positive end-expiratory pressure (PEEP), the extent to which expansion of previously opened (vs. newly opening) peripheral airspaces contribute to increased lung volume is unknown. METHODS Following a recruitment maneuver, rats were ventilated with constant tidal volumes and imaged during ascending and descending ramps of PEEP. RESULTS The authors estimated peripheral airspace dimensions by measuring the apparent diffusion coefficient of He in 10 rats. In a separate group (n = 5) undergoing a similar protocol, the authors used computerized tomography to quantify lung volume. Hysteresis was confirmed by larger end-inspiratory lung volume (mean ± SD; all PEEP levels included): 8.4 ± 2.8 versus 6.8 ± 2.0 ml (P < 0.001) and dynamic compliance: 0.52 ± 0.12 versus 0.42 ± 0.09 ml/cm H2O (P < 0.001) during descending versus ascending PEEP ramps. Apparent diffusion coefficient increased with PEEP, but it was smaller during the descending versus ascending ramps for corresponding levels of PEEP: 0.168 ± 0.019 versus 0.183 ± 0.019 cm/s (P < 0.001). Apparent diffusion coefficient was smaller in the posterior versus anterior lung regions, but the effect of PEEP and hysteresis on apparent diffusion coefficient was greater in the posterior regions. CONCLUSIONS The authors' study results suggest that in healthy lungs, larger lung volumes due to hysteresis are associated with smaller individual airspaces. This may be explained by opening of previously nonaerated peripheral airspaces rather than expansion of those already aerated. Setting PEEP on a descending ramp may minimize distension of individual airspaces.
Collapse
|
35
|
Regional alveolar partial pressure of oxygen measurement with parallel accelerated hyperpolarized gas MRI. Acad Radiol 2013; 20:1224-33. [PMID: 24029054 DOI: 10.1016/j.acra.2013.07.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Revised: 06/19/2013] [Accepted: 07/03/2013] [Indexed: 11/16/2022]
Abstract
RATIONALE AND OBJECTIVES Alveolar oxygen tension (Pao2) is sensitive to the interplay between local ventilation, perfusion, and alveolar-capillary membrane permeability, and thus reflects physiologic heterogeneity of healthy and diseased lung function. Several hyperpolarized helium ((3)He) magnetic resonance imaging (MRI)-based Pao2 mapping techniques have been reported, and considerable effort has gone toward reducing Pao2 measurement error. We present a new Pao2 imaging scheme, using parallel accelerated MRI, which significantly reduces measurement error. MATERIALS AND METHODS The proposed Pao2 mapping scheme was computer-simulated and was tested on both phantoms and five human subjects. Where possible, correspondence between actual local oxygen concentration and derived values was assessed for both bias (deviation from the true mean) and imaging artifact (deviation from the true spatial distribution). RESULTS Phantom experiments demonstrated a significantly reduced coefficient of variation using the accelerated scheme. Simulation results support this observation and predict that correspondence between the true spatial distribution and the derived map is always superior using the accelerated scheme, although the improvement becomes less significant as the signal-to-noise ratio increases. Paired measurements in the human subjects, comparing accelerated and fully sampled schemes, show a reduced Pao2 distribution width for 41 of 46 slices. CONCLUSION In contrast to proton MRI, acceleration of hyperpolarized imaging has no signal-to-noise penalty; its use in Pao2 measurement is therefore always beneficial. Comparison of multiple schemes shows that the benefit arises from a longer time-base during which oxygen-induced depolarization modifies the signal strength. Demonstration of the accelerated technique in human studies shows the feasibility of the method and suggests that measurement error is reduced here as well, particularly at low signal-to-noise levels.
Collapse
|
36
|
Accelerated fractional ventilation imaging with hyperpolarized Gas MRI. Magn Reson Med 2013; 70:1353-9. [PMID: 23400938 DOI: 10.1002/mrm.24582] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2012] [Revised: 10/24/2012] [Accepted: 11/12/2012] [Indexed: 11/11/2022]
Abstract
PURPOSE To investigate the utility of accelerated imaging to enhance multibreath fractional ventilation (r) measurement accuracy using hyperpolarized gas MRI. Undersampling shortens the breath-hold time, thereby reducing the O2 -induced signal decay and allows subjects to maintain a more physiologically relevant breathing pattern. Additionally, it may improve r estimation accuracy by reducing radiofrequency destruction of hyperpolarized gas. METHODS Image acceleration was achieved using an eight-channel phased array coil. Undersampled image acquisition was simulated in a series of ventilation images and data was reconstructed for various matrix sizes (48-128) using generalized auto-calibrating partially parallel acquisition. Parallel accelerated r imaging was also performed on five mechanically ventilated pigs. RESULTS Optimal acceleration factor was fairly invariable (2.0-2.2×) over the range of simulated resolutions. Estimation accuracy progressively improved with higher resolutions (39-51% error reduction). In vivo r values were not significantly different between the two methods: 0.27 ± 0.09, 0.35 ± 0.06, 0.40 ± 0.04 (standard) versus 0.23 ± 0.05, 0.34 ± 0.03, 0.37 ± 0.02 (accelerated); for anterior, medial, and posterior slices, respectively, whereas the corresponding vertical r gradients were significant (P < 0.001): 0.021 ± 0.007 (standard) versus 0.019 ± 0.005 (accelerated) (cm(-1) ). CONCLUSION Quadruple phased array coil simulations resulted in an optimal acceleration factor of ∼2× independent of imaging resolution. Results advocate undersampled image acceleration to improve accuracy of fractional ventilation measurement with hyperpolarized gas MRI.
Collapse
|
37
|
Abstract
OBJECTIVE Atelectasis and surfactant depletion may contribute to greater distension-and thereby injury-of aerated lung regions; recruitment of atelectatic lung may protect these regions by attenuating such overdistension. However, the effects of atelectasis (and recruitment) on aerated airspaces remain elusive. We tested the hypothesis that during mechanical ventilation, surfactant depletion increases the dimensions of aerated airspaces and that lung recruitment reverses these changes. DESIGN Prospective imaging study in an animal model. SETTING Research imaging facility. SUBJECTS Twenty-seven healthy Sprague Dawley rats. INTERVENTIONS Surfactant depletion was obtained by saline lavage in anesthetized, ventilated rats. Alveolar recruitment was accomplished using positive end-expiratory pressure and exogenous surfactant administration. MEASUREMENTS AND MAIN RESULTS Airspace dimensions were estimated by measuring the apparent diffusion coefficient of He, using diffusion-weighted hyperpolarized gas magnetic resonance imaging. Atelectasis was demonstrated using computerized tomography and by measuring oxygenation. Saline lavage increased atelectasis (increase in nonaerated tissue from 1.2% to 13.8% of imaged area, p < 0.001), and produced a concomitant increase in mean apparent diffusion coefficient (~33%, p < 0.001) vs. baseline; the heterogeneity of the computerized tomography signal and the variance of apparent diffusion coefficient were also increased. Application of positive end-expiratory pressure and surfactant reduced the mean apparent diffusion coefficient (~23%, p < 0.001), and its variance, in parallel to alveolar recruitment (i.e., less computerized tomography densities and heterogeneity, increased oxygenation). CONCLUSIONS Overdistension of aerated lung occurs during atelectasis is detectable using clinically relevant magnetic resonance imaging technology, and could be a key factor in the generation of lung injury during mechanical ventilation. Lung recruitment by higher positive end-expiratory pressure and surfactant administration reduces airspace distension.
Collapse
|
38
|
Metabolism of hyperpolarized [1-¹³C]pyruvate in the isolated perfused rat lung - an ischemia study. NMR IN BIOMEDICINE 2012; 25:1113-8. [PMID: 22311307 PMCID: PMC3399019 DOI: 10.1002/nbm.2777] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2011] [Revised: 11/03/2011] [Accepted: 12/20/2011] [Indexed: 05/10/2023]
Abstract
We report studies of the effect of ischemia on the metabolic activity of the intact perfused lung and its restoration after a period of reperfusion. Two groups of rat lungs were studied using hyperpolarized 1-(13) C pyruvate to compare the rate of lactate labeling differing only in the temporal ordering of ischemic and normoxic acquisitions. In both cases, a several-fold increase in lactate labeling was observed immediately after a 25-min ischemia event as was its reversal back to the baseline after 30-40 min of resumed perfusion (n = 5, p < 0.025 for both comparisons). These results were corroborated by (31) P spectroscopy and correspond well to measured changes in lactate pool size determined by (1) H spectroscopy of freeze-clamped specimens.
Collapse
|
39
|
Multislice fractional ventilation imaging in large animals with hyperpolarized gas MRI. NMR IN BIOMEDICINE 2012; 25:1015-1025. [PMID: 22290603 PMCID: PMC3362674 DOI: 10.1002/nbm.2763] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 11/17/2011] [Accepted: 11/22/2011] [Indexed: 05/31/2023]
Abstract
The noninvasive assessment of regional lung ventilation is of critical importance in the quantification of the severity of disease and evaluation of response to therapy in many pulmonary diseases. This work presents, for the first time, the implementation of a hyperpolarized (HP) gas MRI technique to measure whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in the supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the radiofrequency pulse decay effect from the ventilatory signal build-up in the airways, the regional distribution of the flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no interscan time delay during a breath-hold at the tail end of the ventilation sequence. Analysis was performed to assess the sensitivity of the multislice ventilation model to noise, oxygen and the number of flip angle images. The optimal α value was determined on the basis of the minimization of the error in r estimation: α(opt) = 5-6º for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27 ± 0.09, 0.35 ± 0.06 and 0.40 ± 0.04 for the ventral, middle and dorsal slices, respectively (excluding conductive airways r 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. The results demonstrate the feasibility of the measurement of the fractional ventilation in large species, and provide a platform to address the technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of humans.
Collapse
|
40
|
Regional determination of oxygen uptake in rodent lungs using hyperpolarized gas and an analytical treatment of intrapulmonary gas redistribution. NMR IN BIOMEDICINE 2011; 24:1253-1263. [PMID: 21387449 DOI: 10.1002/nbm.1685] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2010] [Revised: 12/09/2010] [Accepted: 01/10/2011] [Indexed: 05/30/2023]
Abstract
A method is presented which allows for the accurate extraction of regional functional metrics in rodent lungs using hyperpolarized gas. The technique is based on the combination of measured T(1) decay, an independent measure of specific ventilation and mass balance considerations to extract the regional oxygen levels and uptake. In phantom and animal experiments, it is demonstrated that the redistribution of gas during the measurement is a significant confounding factor, and this effect is addressed analytically. The resulting parameterization of gas flow increases the accuracy of oxygen-sensitive MRI, and may also be used independently to assess air trapping and airway constriction. Limitations of the technique with respect to spatial resolution and robustness are also discussed.
Collapse
|
41
|
A simple and low-cost device for generating hyperpolarized contrast agents using parahydrogen. NMR IN BIOMEDICINE 2011; 24:933-42. [PMID: 21845739 DOI: 10.1002/nbm.1757] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2010] [Revised: 04/28/2011] [Accepted: 05/09/2011] [Indexed: 05/12/2023]
Abstract
A detailed description of the construction and use of a device for hyperpolarization of select contrast agents is presented. The device is based on molecular incorporation of the spin-order inherent to parahydrogen, followed by order transfer to a metastable heteronuclear alignment. Design considerations and experimental results relating to catalyst/solvent choice and handling, solvent heating, efficient gas entrainment and spin-order transfer are described. The resulting degree of hyperpolarization is shown to be substantial, ranging from a few to over 50%, depending on the choice of target molecule. Finally, the use of the hyperpolarized agent is demonstrated in a series of in vivo images.
Collapse
|
42
|
Regional function-structure relationships in lungs of an elastase murine model of emphysema. J Appl Physiol (1985) 2011; 112:135-48. [PMID: 21940853 DOI: 10.1152/japplphysiol.01181.2010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Changes in lung function and structure were studied using hyperpolarized (3)He MRI in an elastase-induced murine model of emphysema. The combined analysis of the apparent diffusion coefficient (ADC) and fractional ventilation (R) were used to distinguish emphysematous changes and also to develop a model for classifying sections of the lung into diseased and normal. Twelve healthy male BALB/c mice (26 ± 2 g) were randomized into healthy and elastase-induced mice and studied ∼8-11 wk after model induction. ADC and R were measured at a submillimeter planar resolution. Chord length (L(x)) data were analyzed from histology samples from the corresponding imaged slices. Logistic regression was applied to estimate the probability that an imaged pixel came from a diseased animal, and bootstrap methods (1,000 samples) were used to compare the regression results for the morphological and imaging results. Multivariate ANOVA (MANOVA) was used to analyze transformed ADC (ADC(BC)), and R (R(BC)) data and also to control for the experiment-wide error rate. MANOVA and ANOVA showed that elastase induced a statistically measureable change in the average transformed L(x) and ADC(BC) but not in the average R(BC). Marginal mean analysis demonstrated that ADC(BC) was on average 0.19 [95% confidence interval (CI): 0.16, 0.22] higher in the emphysema group, whereas R(BC) was on average 0.05 (95% CI: 0.04, 0.06) lower. Logistic regression supported the hypothesis that ADC(BC) and R(BC), together, were better at differentiating normal from diseased tissue than either measurement alone. The odds ratios for ADC(BC) and R(BC) were 7.73 (95% CI: 5.23, 11.42) and 9.14 × 10(-5) (95% CI: 3.33 × 10(-5), 25.06 × 10(-5)), respectively. Using a 50% probability cutoff, this model classified 70.6% of pixels correctly. The sensitivity and specificity of this model at the 50% cutoff were 74.9% and 65.2%, respectively. The area under the receiver operating characteristic curve was 0.76 (95% CI: 0.74, 0.78). The regression model presented can be used to map MRI data to disease probability maps. These probability maps present a future possibility of using both measurements in a more clinically feasible method of diagnosing this disease.
Collapse
|
43
|
Quantitative imaging of alveolar recruitment with hyperpolarized gas MRI during mechanical ventilation. J Appl Physiol (1985) 2011; 110:499-511. [PMID: 21127207 PMCID: PMC3043787 DOI: 10.1152/japplphysiol.00841.2010] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2010] [Accepted: 12/01/2010] [Indexed: 12/31/2022] Open
Abstract
The aim of this study was to assess the utility of (3)He MRI to noninvasively probe the effects of positive end-expiratory pressure (PEEP) maneuvers on alveolar recruitment and atelectasis buildup in mechanically ventilated animals. Sprague-Dawley rats (n = 13) were anesthetized, intubated, and ventilated in the supine position ((4)He-to-O(2) ratio: 4:1; tidal volume: 10 ml/kg, 60 breaths/min, and inspiration-to-expiration ratio: 1:2). Recruitment maneuvers consisted of either a stepwise increase of PEEP to 9 cmH(2)O and back to zero end-expiratory pressure or alternating between these two PEEP levels. Diffusion MRI was performed to image (3)He apparent diffusion coefficient (ADC) maps in the middle coronal slices of lungs (n = 10). ADC was measured immediately before and after two recruitment maneuvers, which were separated from each other with a wait period (8-44 min). We detected a statistically significant decrease in mean ADC after each recruitment maneuver. The relative ADC change was -21.2 ± 4.1 % after the first maneuver and -9.7 ± 5.8 % after the second maneuver. A significant relative increase in mean ADC was observed over the wait period between the two recruitment maneuvers. The extent of this ADC buildup was time dependent, as it was significantly related to the duration of the wait period. The two postrecruitment ADC measurements were similar, suggesting that the lungs returned to the same state after the recruitment maneuvers were applied. No significant intrasubject differences in ADC were observed between the corresponding PEEP levels in two rats that underwent three repeat maneuvers. Airway pressure tracings were recorded in separate rats undergoing one PEEP maneuver (n = 3) and showed a significant relative difference in peak inspiratory pressure between pre- and poststates. These observations support the hypothesis of redistribution of alveolar gas due to recruitment of collapsed alveoli in presence of atelectasis, which was also supported by the decrease in peak inspiratory pressure after recruitment maneuvers.
Collapse
|
44
|
Quantitative assessment of lung ventilation and microstructure in an animal model of idiopathic pulmonary fibrosis using hyperpolarized gas MRI. Acad Radiol 2010; 17:1433-43. [PMID: 20934126 DOI: 10.1016/j.acra.2010.06.019] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Revised: 06/24/2010] [Accepted: 06/24/2010] [Indexed: 11/16/2022]
Abstract
RATIONALE AND OBJECTIVES The use of hyperpolarized (3)He magnetic resonance imaging as a quantitative lung imaging tool has progressed rapidly in the past decade, mostly in the assessment of the airway diseases chronic obstructive pulmonary disease and asthma. This technique has shown potential to assess both structural and functional information in healthy and diseased lungs. In this study, the regional measurements of structure and function were applied to a bleomycin rat model of interstitial lung disease. MATERIALS AND METHODS Male Sprague-Dawley rats (weight, 300-350 g) were administered intratracheal bleomycin. After 3 weeks, apparent diffusion coefficient and fractional ventilation were measured by (3)He magnetic resonance imaging and pulmonary function testing using a rodent-specific plethysmography chamber. Sensitized and healthy animals were then compared using threshold analysis to assess the potential sensitivity of these techniques to pulmonary abnormalities. RESULTS No significant changes were observed in total lung volume and compliance between the two groups. Airway resistance elevated and forced expiratory volume significantly declined in the 3-week bleomycin rats, and fractional ventilation was significantly decreased compared to control animals (P < .0004). The apparent diffusion coefficient of (3)He showed a smaller change but still a significant decrease in 3-week bleomycin animals (P < .05). CONCLUSIONS Preliminary results suggest that quantitative (3)He magnetic resonance imaging can be a sensitive and noninvasive tool to assess changes in an animal interstitial lung disease model. This technique may be useful for longitudinal animal studies and also in the investigation of human interstitial lung diseases.
Collapse
|
45
|
Regional correlation of emphysematous changes in lung function and structure: a comparison between pulmonary function testing and hyperpolarized MRI metrics. J Appl Physiol (1985) 2010; 110:225-35. [PMID: 20884833 DOI: 10.1152/japplphysiol.00269.2010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Regional and global relationships of lung function and structure were studied using hyperpolarized ³He MRI in a rat elastase-induced model of emphysema (n = 4) and healthy controls (n = 5). Fractional ventilation (r) and apparent diffusion coefficient (ADC) of ³He were measured at a submillimeter planar resolution in ventral, middle, and dorsal slices 6 mo after model induction. Pulmonary function testing (PFT) was performed before MRI to yield forced expiratory volume in 50 ms (FEV₅₀), airway resistance (R(I)), and dynamic compliance (C(dyn)). Cutoff threshold values of ventilation and diffusion, r* and ADC*, were computed corresponding to 80% population of pixels falling above or below each threshold value, respectively. For correlation analysis, r* was compared with FEV₅₀/functional residual capacity (FRC), R(I) and C(dyn), whereas ADC* was compared with FEV₅₀/FRC, total lung capacity (TLC), and C(dyn). Regional correlation of r and ADC was evaluated by dividing each of the three lung slices into four quadrants. C(dyn) was significantly larger in elastase rats (0.92 ± 0.16 vs. 0.61 ± 0.12 ml/cmH₂O). The difference of R(I) and FEV₅₀ was insignificant between the two groups. The r* of healthy rats was significantly larger than the elastase group (0.42 ± 0.03 vs. 0.28 ± 0.06), whereas ADC* was significantly smaller in healthy animals (0.27 ± 0.04 vs. 0.36 ± 0.01 cm²/s). No systematic difference in these quantities was observed between the three lung slices. A significant 33% increase in ADC* and a significant 31% decline in r* for elastase rats was observed compared with a significant 51% increase in C(dyn) and a nonsignificant 26% decline in FEV₅₀/FRC. Correlation of imaging and PFT metrics revealed that r and ADC divide the rats into two separate clusters in the sample space.
Collapse
|
46
|
Optimal transfer of spin-order between a singlet nuclear pair and a heteronucleus. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 205:9-13. [PMID: 20427216 PMCID: PMC2885468 DOI: 10.1016/j.jmr.2010.03.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2010] [Revised: 02/26/2010] [Accepted: 03/03/2010] [Indexed: 05/12/2023]
Abstract
Intramolecular spin-order transfer is a useful technique for signal enhancement of insensitive and low-concentration molecular species. We present a closed-form, optimized pulse sequence which maximizes the efficiency of transfer between a singlet (para) nuclear pair and a vicinal heteronucleus. Neglecting the decay of coherences while the nuclei are in the transverse plane, the scheme is unity efficient for all combinations of internuclear scalar couplings. Efficiency loss due to T2-like decay is also minimized by keeping the sequence as short as possible. We expect this result to be useful for hyperpolarization experiments in which the spin-order originates in parahydrogen, as well as studies of singlet state decay aimed at longer-term storage of spin-order in hyperpolarized Magnetic Resonance Imaging.
Collapse
|
47
|
Simultaneous measurement of pulmonary partial pressure of oxygen and apparent diffusion coefficient by hyperpolarized 3He MRI. Magn Reson Med 2009; 61:1015-21. [PMID: 19230017 DOI: 10.1002/mrm.21854] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Hyperpolarized (3)He (HP (3)He) MRI shows promise to assess structural and functional pulmonary parameters in a sensitive, regional, and noninvasive way. Structural HP (3)He MRI has applied the apparent diffusion coefficient (ADC) for the detection of disease-induced lung microstructure changes at the alveolar level, and HP (3)He pulmonary partial pressure of oxygen (pO(2)) imaging measures the oxygen transfer efficiency between the lung and blood stream. Although both parameters are affected in chronic obstructive pulmonary disease (COPD), a quantitative assessment of the regional correlation of the two parameters has not been reported in the literature. In this work, a single acquisition technique for the simultaneous measurement of ADC and pO(2) is presented. This technique is based on the multiple regression method, in which a general linear estimator is used to retrieve the values of ADC and pO(2) from a series of measurements. The measurement uncertainties are also analytically derived and used to find an optimal measurement scheme. The technique was first tested on a phantom model, and then on an in vivo normal pig experiment. A case study was performed on a COPD patient, which showed that in a region of interest ADC was 29% higher while oxygen depletion rate was 61% lower than the corresponding global average values.
Collapse
|
48
|
Measurement of pulmonary partial pressure of oxygen and oxygen depletion rate with hyperpolarized helium-3 MRI: a preliminary reproducibility study on pig model. Acad Radiol 2008; 15:702-12. [PMID: 18486007 DOI: 10.1016/j.acra.2008.01.024] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2007] [Revised: 01/18/2008] [Accepted: 01/19/2008] [Indexed: 10/22/2022]
Abstract
RATIONAL AND OBJECTIVES Pulmonary partial pressure of oxygen (pO(2)) and oxygen depletion rate (R) are two important parameters of lung function. The dependence of hyperpolarized (3)He (HP (3)He) T(1) on local oxygen concentration provides the basis for high-resolution mapping of the regional distributions of pO(2) and R in the lung. Although the oxygen-sensitive HP (3)He magnetic resonance imaging technique has been applied in human subjects and several animal species, reproducibility studies are rarely reported in the literature. This work presents a preliminary reproducibility study on a pig model. In this study, important scan parameters, such as measurement timing and flip angle, are optimized to minimize the noise-induced measurement uncertainty. MATERIALS AND METHODS In the in vivo study, five normal pigs and one diseased pig with simulated pulmonary emboli were scanned with a small flip angle gradient echo sequence. The pulmonary oxygen measurement was repeated two to four times in each pig. In each measurement, a series of six images were acquired with optimal timing and flip angle. The parametric maps were generated using a bin-based data processing procedure that applied the multiple regression fitting method to extract the pO(2) and R. Variations of global mean, percentiles, and regions of interest were calculated from the maps to analyze reproducibility. RESULTS The global statistical analyses show that average variation of global mean is 10.7% for pO(2) and 23.8% for R, and that the average variation of percentiles (10th, 25th, 50th, 75th, and 90th) and interquartile range is 14.8% for pO(2) and 30.4% for R. The region-of-interest analysis on the manually selected regions shows that the average variation of mean is 12.6% for pO(2) and 21.9% for R. CONCLUSION In this work, a preliminary study on the reproducibility of measuring pO(2) and R with HP (3)He magnetic resonance imaging on a pig model is presented.
Collapse
|
49
|
A robust method for estimating regional pulmonary parameters in presence of noise. Acad Radiol 2008; 15:740-52. [PMID: 18486010 DOI: 10.1016/j.acra.2008.03.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2007] [Revised: 03/11/2008] [Accepted: 03/17/2008] [Indexed: 10/22/2022]
Abstract
RATIONALE AND OBJECTIVES Estimation of regional lung function parameters from hyperpolarized gas magnetic resonance images can be very sensitive to presence of noise. Clustering pixels and averaging over the resulting groups is an effective method for reducing the effects of noise in these images, commonly performed by grouping proximal pixels together, thus creating large groups called "bins." This method has several drawbacks, primarily that it can group dissimilar pixels together, and it degrades spatial resolution. This study presents an improved approach to simplifying data via principal component analysis (PCA) when noise level prohibits a pixel-by-pixel treatment of data, by clustering them based on similarity to one another rather than spatial proximity. The application to this technique is demonstrated in measurements of regional lung oxygen tension using hyperpolarized (3)He magnetic resonance imaging (MRI). MATERIALS AND METHODS A synthetic dataset was generated from an experimental set of oxygen tension measurements by treating the experimentally derived parameters as "true" values, and then solving backwards to generate "noiseless" images. Artificial noise was added to the synthetic data, and both traditional binning and PCA-based clustering were performed. For both methods, the root-mean-square (RMS) error between each pixel's "estimated" and "true" parameters was computed and the resulting effects were compared. RESULTS At high signal-to-noise ratios (SNRs), clustering did not enhance accuracy. Clustering did, however, improve parameter estimations for moderate SNR values (below 100). For SNR values between 100 and 20, the PCA-based K-means clustering analysis yielded greater accuracy than Cartesian binning. In extreme cases (SNR<5), Cartesian binning can be more accurate. CONCLUSIONS The reliability of parameters estimation in imaging-based regional functional measurements can be improved in the presence of noise by utilizing principal component analysis-based clustering without sacrificing spatial resolution compared to Cartesian binning. Results suggest that this approach has a great potential for robust grouping of pixels in hyperpolarized (3)He MRI maps of lung oxygen tension.
Collapse
|
50
|
Optimization of scan parameters in pulmonary partial pressure oxygen measurement by hyperpolarized 3He MRI. Magn Reson Med 2008; 59:124-31. [PMID: 18050348 DOI: 10.1002/mrm.21416] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The dependence of hyperpolarized (HP) (3)He T(1) on local oxygen concentration provides the basis for measuring the partial pressure of oxygen (pO(2)) and oxygen depletion rate (R) in the lungs. Precise measurements of this type are difficult because the oxygen effect manifests itself through a decay of signal, leading to noisy images at the end of the series. The depolarization caused by RF excitation pulses further complicates the problem. It is therefore important to optimize scan parameters, such as measurement timing and flip angle, to obtain accurate and reproducible measurements. This work presents a new single-acquisition technique in conjunction with the multiple regression fitting method for data evaluation. Analytical expressions for the measurement uncertainties are derived. A total of four types of single-acquisition timing schemes are investigated; simulation shows a large uncertainty variation between these schemes (pO(2): 7.5-30.2%; R: 47.4-173.7%). A basic procedure for optimizing scan parameters is then described. A phantom experiment was conducted to verify the simulation results. Repeated in vivo measurements with the optimal scheme in a rabbit experiment showed that average variation of global mean is 6.2% for pO(2) and 12.0% for R, and that the average variation of percentiles (10th, 25th, 50th, 75th, and 90th) is 8.7% for pO(2) and 19.0% for R.
Collapse
|