First-in-Human Phase I Trial Combining Biologically Guided Radioimmunotherapy (RIT) Using a 90Y-Anti-CD25 Monoclonal Antibody (Mab) with CT-guided Total Marrow and Lymphoid Irradiation (TMLI) in Relapsed and Refractory (R/R) Acute Leukemia. Int J Radiat Oncol Biol Phys 2023; 117:S162. [PMID: 37784406 DOI: 10.1016/j.ijrobp.2023.06.256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) Patients with R/R acute leukemia after allogeneic hematopoietic cell transplant (alloHCT) have a dismal prognosis with 3-year survival rates of < 20%. To improve outcomes, innovative targeted forms of organ sparing radiotherapy, such as tumor-specific RIT and TMLI, are needed to dose escalate with acceptable toxicities, especially in patients ≥ age 60 years who cannot tolerate total body irradiation (TBI) / myeloablative regimens and who have a poor prognosis. CD25 is an ideal RIT target given its expression in acute leukemias, association with poor prognosis, and expression by leukemia stem cells. In this phase I trial (NCT05139004) we hypothesized that combining dose escalated 90Y-anti-CD25 RIT with fixed dose TMLI 12 Gy, fludarabine (flu), and melphalan (mel) in patients with R/R disease is safe and associated with acceptable toxicities. MATERIALS/METHODS The primary objective of this trial is to determine the maximum tolerated dose and recommended phase 2 dose of 90Y-anti-CD25 Mab (Day -15) with 12 Gy TMLI (1.5 Gy twice a day, days -8 to -5), flu (30 mg/m2/d days -5 to -2), and mel (100 mg/m2, day -2) in patients ≥ 60 years old or with a HCT-comorbidity index ≥ 2 and with R/R AML, ALL or myelodysplastic syndrome (MDS) scheduled to undergo alloHCT from a matched donor. TMLI mean organ dose constraints for kidney, lung and liver were 4 Gy. Planned dose levels of 90Y-anti-CD25 were 0.3, 0.4, and 0.5 mCi/kg. 111In-anti-CD25 (5 mCi) was co-infused followed by serial nuclear scans to assess dosimetry and biodistribution. RESULTS To date 5 patients (ages 31-74) with R/R AML have been treated. Marrow and circulating blasts ranged from 10-36% and 9-44%, respectively. For the 3 patients at 0.3 mCi/kg, follow-up ranged from 89-191+ days. 90Y/111In-anti-CD25 nuclear scans demonstrated persistent uptake in bone out to 144 hours, which was associated with a decline in circulating blasts. After combined RIT and TMLI, mean doses (Gy) to lungs ranged from 5.7-6.5, to kidneys from 7.5-8.2 and to liver from 7.2-11.6. No dose-limiting toxicities (DLT) were observed. All 3 patients achieved CR on day +30 bone marrow biopsies and 2 remained in CR on day +90 biopsies. Two patients have recently been treated at the 0.4 mCi/kg dose level. The results of patients treated at the higher dose levels will be provided. CONCLUSION Dose escalation by adding 90Y-anti-CD25 RIT at 0.3 mCi/kg to 12 Gy TMLI was safe, including in older patients, with no dose-limiting toxicities, mean critical organ doses lower than conventional myeloablative TBI, and encouraging response rates. The toxicity profile and dose estimates at 0.3 mCi/kg predict that the planned higher dose levels will also be feasible with acceptable toxicities. RIT and TMLI are complementary and when combined address the limitations of each modality. Combining these targeted therapies may be a superior strategy to intensify dose to leukemia compared to dose escalation of either modality alone.
Collapse
|
2
|
Total marrow irradiation reduces organ damage and enhances tissue repair with the potential to increase the targeted dose of bone marrow in both young and old mice. Front Oncol 2022; 12:1045016. [PMID: 36439420 PMCID: PMC9686437 DOI: 10.3389/fonc.2022.1045016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 10/17/2022] [Indexed: 11/11/2022] Open
Abstract
Total body irradiation (TBI) is a commonly used conditioning regimen for hematopoietic stem cell transplant (HCT), but dose heterogeneity and long-term organ toxicity pose significant challenges. Total marrow irradiation (TMI), an evolving radiation conditioning regimen for HCT can overcome the limitations of TBI by delivering the prescribed dose targeted to the bone marrow (BM) while sparing organs at risk. Recently, our group demonstrated that TMI up to 20 Gy in relapsed/refractory AML patients was feasible and efficacious, significantly improving 2-year overall survival compared to the standard treatment. Whether such dose escalation is feasible in elderly patients, and how the organ toxicity profile changes when switching to TMI in patients of all ages are critical questions that need to be addressed. We used our recently developed 3D image-guided preclinical TMI model and evaluated the radiation damage and its repair in key dose-limiting organs in young (~8 weeks) and old (~90 weeks) mice undergoing congenic bone marrow transplant (BMT). Engraftment was similar in both TMI and TBI-treated young and old mice. Dose escalation using TMI (12 to 16 Gy in two fractions) was well tolerated in mice of both age groups (90% survival ~12 Weeks post-BMT). In contrast, TBI at the higher dose of 16 Gy was particularly lethal in younger mice (0% survival ~2 weeks post-BMT) while old mice showed much more tolerance (75% survival ~13 weeks post-BMT) suggesting higher radio-resistance in aged organs. Histopathology confirmed worse acute and chronic organ damage in mice treated with TBI than TMI. As the damage was alleviated, the repair processes were augmented in the TMI-treated mice over TBI as measured by average villus height and a reduced ratio of relative mRNA levels of amphiregulin/epidermal growth factor (areg/egf). These findings suggest that organ sparing using TMI does not limit donor engraftment but significantly reduces normal tissue damage and preserves repair capacity with the potential for dose escalation in elderly patients.
Collapse
|
3
|
Development of a theranostic preclinical fluorescence molecular tomography/cone beam CT-guided irradiator platform. BIOMEDICAL OPTICS EXPRESS 2022; 13:6100-6112. [PMID: 36733750 PMCID: PMC9872876 DOI: 10.1364/boe.469559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/21/2022] [Accepted: 09/22/2022] [Indexed: 05/11/2023]
Abstract
Image-guided small animal radiation research platforms allow more precise radiation treatment. Commercially available small animal X-ray irradiators are often equipped with a CT/cone-beam CT (CBCT) component for target guidance. Besides having poor soft-tissue contrast, CBCT unfortunately cannot provide molecular information due to its low sensitivity. Hence, there are extensive efforts to incorporate a molecular imaging component besides CBCT on these radiation therapy platforms. As an extension of these efforts, here we present a theranostic fluorescence tomography/CBCT-guided irradiator platform that provides both anatomical and molecular guidance, which can overcome the limitations of stand-alone CBCT. The performance of our hybrid system is validated using both tissue-like phantoms and mice ex vivo. Both studies show that fluorescence tomography can provide much more accurate quantitative results when CBCT-derived structural information is used to constrain the inverse problem. The error in the recovered fluorescence absorbance reduces nearly 10-fold for all cases, from approximately 60% down to 6%. This is very significant since high quantitative accuracy in molecular information is crucial to the correct assessment of the changes in tumor microenvironment related to radiation therapy.
Collapse
|
4
|
Development and characterization of a preclinical total marrow irradiation conditioning-based bone marrow transplant model for sickle cell disease. Front Oncol 2022; 12:969429. [PMID: 36147914 PMCID: PMC9485604 DOI: 10.3389/fonc.2022.969429] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 08/05/2022] [Indexed: 11/29/2022] Open
Abstract
Sickle cell disease (SCD) is a serious global health problem, and currently, the only curative option is hematopoietic stem cell transplant (HCT). However, myeloablative total body irradiation (TBI)-based HCT is associated with high mortality/morbidity in SCD patients. Therefore, reduced-intensity (2–4 Gy) total body radiation (TBI) is currently used as a conditioning regimen resulting in mixed chimerism with the rescue of the SCD disease characteristic features. However, donor chimerism gradually reduces in a few years, resulting in a relapse of the SCD features, and organ toxicities remained the primary concern for long-term survivors. Targeted marrow irradiation (TMI) is a novel technique developed to deliver radiation to the desired target while sparing vital organs and is successfully used for HCT in refractory/relapsed patients with leukemia. However, it is unknown if TMI will be an effective treatment for a hematological disorder like SCD without adverse effects seen on TBI. Therefore, we examined preclinical feasibility to determine the tolerated dose escalation, its impact on donor engraftment, and reduction in organ damage using our recently developed TMI in the humanized homozygous Berkley SCD mouse model (SS). We show that dose-escalated TMI (8:2) (8 Gy to the bone marrow and 2 Gy to the rest of the body) is tolerated with reduced organ pathology compared with TBI (4:4)-treated mice. Furthermore, with increased SCD control (AA) mice (25 million) donor BM cells, TMI (8:2)-treated mice show successful long-term engraftment while engraftment failed in TBI (2:2)-treated mice. We further evaluated the benefit of dose-escalated TMI and donor cell engraftment in alleviating SCD features. The donor engraftment in SCD mice completely rescues SCD disease features including recovery in RBCs, hematocrit, platelets, and reduced reticulocytes. Moreover, two-photon microscopy imaging of skull BM of transplanted SCD mice shows reduced vessel density and leakiness compared to untreated control SCD mice, indicating vascular recovery post-BMT.
Collapse
|
5
|
Feasibility of a Novel Sparse Orthogonal Collimator-Based Preclinical Total Marrow Irradiation for Enhanced Dosimetric Conformality. Front Oncol 2022; 12:941814. [PMID: 35924145 PMCID: PMC9339640 DOI: 10.3389/fonc.2022.941814] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 06/23/2022] [Indexed: 12/17/2022] Open
Abstract
Total marrow irradiation (TMI) has significantly improved radiation conditioning for hematopoietic cell transplantation in hematologic diseases by reducing conditioning-induced toxicities and improving survival outcomes in relapsed/refractory patients. Recently, preclinical three-dimensional image-guided TMI has been developed to enhance mechanistic understanding of the role of TMI and to support the development of experimental therapeutics. However, a dosimetric comparison between preclinical and clinical TMI reveals that the preclinical TMI treatment lacks the ability to reduce the dose to some of the vital organs that are very close to the skeletal system and thus limits the ability to evaluate radiobiological relevance. To overcome this limit, we introduce a novel Sparse Orthogonal Collimator (SOC)-based TMI and evaluate its ability to enhance dosimetric conformality. The SOC-TMI-based dose modulation technique significantly improves TMI treatment planning by reducing radiation exposures to critical organs that are close to the skeletal system that leads to reducing the gap between clinical and preclinical TMI.
Collapse
|
6
|
Longitudinal Preclinical Imaging Characterizes Extracellular Drug Accumulation After Radiation Therapy in the Healthy and Leukemic Bone Marrow Vascular Microenvironment. Int J Radiat Oncol Biol Phys 2022; 112:951-963. [PMID: 34767936 PMCID: PMC9038217 DOI: 10.1016/j.ijrobp.2021.10.146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 08/24/2021] [Accepted: 10/22/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Recent initial findings suggest that radiation therapy improves blood perfusion and cellular chemotherapy uptake in mice with leukemia. However, the ability of radiation therapy to influence drug accumulation in the extracellular bone marrow tissue is unknown, due in part to a lack of methodology. This study developed longitudinal quantitative multiphoton microscopy (L-QMPM) to characterize the bone marrow vasculature (BMV) and drug accumulation in the extracellular bone marrow tissue before and after radiation therapy in mice bearing leukemia. METHODS AND MATERIALS We developed a longitudinal window implant for L-QMPM imaging of the calvarium BMV before, 2 days after, and 5 days after total body irradiation (TBI). Live time-lapsed images of a fluorescent drug surrogate were used to obtain measurements, including tissue wash-in slope (WIStissue) to measure extracellular drug accumulation. We performed L-QMPM imaging on healthy C57BL/6 (WT) mice, as well as mice bearing acute lymphoblastic leukemia (ALL) and acute myeloid leukemia (AML). RESULTS Implants had no effects on calvarium dose, and parameters for wild-type untreated mice were stable during imaging. We observed decreased vessel diameter, vessel blood flow, and WIStissue with the onset of AML and ALL. Two to 10 Gy TBI increased WIStissue and vessel diameter 2 days after radiation therapy in all 3 groups of mice and increased single-vessel blood flow in mice bearing ALL and AML. Increased WIStissue was observed 5 days after 10 Gy TBI or 4 Gy split-dose TBI (2 treatments of 2 Gy spaced 3 days apart). CONCLUSIONS L-QMPM provides stable functional assessments of the BMV. Nonmyeloablative and myeloablative TBI increases extracellular drug accumulation in the leukemic bone marrow 2 to 5 days posttreatment, likely through improved blood perfusion and drug exchange from the BMV to the extravascular tissue. Our data show that neo-adjuvant TBI at doses from 2 Gy to 10 Gy conditions the BMV to improve drug transport to the bone marrow.
Collapse
|
7
|
First Multimodal, Three-Dimensional, Image-Guided Total Marrow Irradiation Model for Preclinical Bone Marrow Transplantation Studies. Int J Radiat Oncol Biol Phys 2021; 111:671-683. [PMID: 34119592 DOI: 10.1016/j.ijrobp.2021.06.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 05/28/2021] [Accepted: 06/04/2021] [Indexed: 01/13/2023]
Abstract
PURPOSE Total marrow irradiation (TMI) has significantly advanced radiation conditioning for hematopoietic cell transplantation in hematologic malignancies by reducing conditioning-induced toxicities and improving survival outcomes in relapsed/refractory patients. However, the relapse rate remains high, and the lack of a preclinical TMI model has hindered scientific advancements. To accelerate TMI translation to the clinic, we developed a TMI delivery system in preclinical models. METHODS AND MATERIALS A Precision X-RAD SmART irradiator was used for TMI model development. Images acquired with whole-body contrast-enhanced computed tomography (CT) were used to reconstruct and delineate targets and vital organs for each mouse. Multiple beam and CT-guided Monte Carlo-based plans were performed to optimize doses to the targets and to vary doses to the vital organs. Long-term engraftment and reconstitution potential were evaluated by a congenic bone marrow transplantation (BMT) model and serial secondary BMT, respectively. Donor cell engraftment was measured using noninvasive bioluminescence imaging and flow cytometry. RESULTS Multimodal imaging enabled identification of targets (skeleton and spleen) and vital organs (eg, lungs, gut, liver). In contrast to total body irradiation (TBI), TMI treatment allowed variation of radiation dose exposure to organs relative to the target dose. Dose reduction mirrored that in clinical TMI studies. Similar to TBI, mice treated with different TMI regimens showed full long-term donor engraftment in primary BMT and second serial BMT. The TBI-treated mice showed acute gut damage, which was minimized in mice treated with TMI. CONCLUSIONS A novel multimodal image guided preclinical TMI model is reported here. TMI conditioning maintained long-term engraftment with reconstitution potential and reduced organ damage. Therefore, this TMI model provides a unique opportunity to study the therapeutic benefit of reduced organ damage and BM dose escalation to optimize treatment regimens in BMT and hematologic malignancies.
Collapse
|
8
|
Biophysical Characterization of the Leukemic Bone Marrow Vasculature Reveals Benefits of Neoadjuvant Low-Dose Radiation Therapy. Int J Radiat Oncol Biol Phys 2021; 109:60-72. [PMID: 32841681 PMCID: PMC7736317 DOI: 10.1016/j.ijrobp.2020.08.037] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 08/04/2020] [Accepted: 08/13/2020] [Indexed: 12/13/2022]
Abstract
PURPOSE Although vascular alterations in solid tumor malignancies are known to decrease therapeutic delivery, the effects of leukemia-induced bone marrow vasculature (BMV) alterations on therapeutic delivery are not well known. Additionally, functional quantitative measurements of the leukemic BMV during chemotherapy and radiation therapy are limited, largely due to a lack of high-resolution imaging techniques available preclinically. This study develops a murine model using compartmental modeling for quantitative multiphoton microscopy (QMPM) to characterize the malignant BMV before and during treatment. METHODS AND MATERIALS Using QMPM, live time-lapsed images of dextran leakage from the local BMV to the surrounding bone marrow of mice bearing acute lymphoblastic leukemia (ALL) were taken and fit to a 2-compartment model to measure the transfer rate (Ktrans), fractional extracellular extravascular space (νec), and vascular permeability parameters, as well as functional single-vessel characteristics. In response to leukemia-induced BMV alterations, the effects of 2 to 4 Gy low-dose radiation therapy (LDRT) on the BMV, drug delivery, and mouse survival were assessed post-treatment to determine whether neoadjuvant LDRT before chemotherapy improves treatment outcome. RESULTS Mice bearing ALL had significantly altered Ktrans, increased νec, and increased permeability compared with healthy mice. Angiogenesis, decreased single-vessel perfusion, and decreased vessel diameter were observed. BMV alterations resulted in disease-dependent reductions in cellular uptake of Hoechst dye. LDRT to mice bearing ALL dilated BMV, increased single-vessel perfusion, and increased daunorubicin uptake by ALL cells. Consequently, LDRT administered to mice before receiving nilotinib significantly increased survival compared with mice receiving LDRT after nilotinib, demonstrating the importance of LDRT conditioning before therapeutic administration. CONCLUSION The developed QMPM enables single-platform assessments of the pharmacokinetics of fluorescent agents and characterization of the BMV. Initial results suggest BMV alterations after neoadjuvant LDRT may contribute to enhanced drug delivery and increased treatment efficacy for ALL. The developed QMPM enables observations of the BMV for use in ALL treatment optimization.
Collapse
|
9
|
3-D Cell Culture Systems in Bone Marrow Tissue and Organoid Engineering, and BM Phantoms as In Vitro Models of Hematological Cancer Therapeutics-A Review. MATERIALS 2020; 13:ma13245609. [PMID: 33316977 PMCID: PMC7763362 DOI: 10.3390/ma13245609] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 10/24/2020] [Accepted: 10/29/2020] [Indexed: 12/15/2022]
Abstract
We review the state-of-the-art in bone and marrow tissue engineering (BMTE) and hematological cancer tissue engineering (HCTE) in light of the recent interest in bone marrow environment and pathophysiology of hematological cancers. This review focuses on engineered BM tissue and organoids as in vitro models of hematological cancer therapeutics, along with identification of BM components and their integration as synthetically engineered BM mimetic scaffolds. In addition, the review details interaction dynamics of various BM and hematologic cancer (HC) cell types in co-culture systems of engineered BM tissues/phantoms as well as their relation to drug resistance and cytotoxicity. Interaction between hematological cancer cells and their niche, and the difference with respect to the healthy niche microenvironment narrated. Future perspectives of BMTE for in vitro disease models, BM regeneration and large scale ex vivo expansion of hematopoietic and mesenchymal stem cells for transplantation and therapy are explained. We conclude by overviewing the clinical application of biomaterials in BM and HC pathophysiology and its challenges and opportunities.
Collapse
|
10
|
Automated in vivo Assessment of Vascular Response to Radiation using a Hybrid Theranostic X-ray Irradiator/Fluorescence Molecular Imaging System. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2020; 8:93663-93670. [PMID: 32542176 PMCID: PMC7295127 DOI: 10.1109/access.2020.2994943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Hypofractionated stereotactic body radiotherapy treatments (SBRT) have demonstrated impressive results for the treatment of a variety of solid tumors. The role of tumor supporting vasculature damage in treatment outcome for SBRT has been intensely debated and studied. Fast, non-invasive, longitudinal assessments of tumor vasculature would allow for thorough investigations of vascular changes correlated with SBRT treatment response. In this paper, we present a novel theranostic system which incorporates a fluorescence molecular imager into a commercial, preclinical, microCT-guided, irradiator and was designed to quantify tumor vascular response (TVR) to targeted radiotherapy. This system overcomes the limitations of single-timepoint imaging modalities by longitudinally assessing spatiotemporal differences in intravenously-injected ICG kinetics in tumors before and after high-dose radiation. Changes in ICG kinetics were rapidly quantified by principle component (PC) analysis before and two days after 10 Gy targeted tumor irradiation. A classifier algorithm based on PC data clustering identified pixels with TVR. Results show that two days after treatment, a significant delay in ICG clearance as measured by exponential decay (40.5±16.1% P=0.0405 Paired t-test n=4) was observed. Changes in the mean normalized first and second PC feature pixel values (PC1 & PC2) were found (P=0.0559, 0.0432 paired t-test), suggesting PC based analysis accurately detects changes in ICG kinetics. The PC based classification algorithm yielded spatially-resolved TVR maps. Our first-of-its-kind theranostic system, allowing automated assessment of TVR to SBRT, will be used to better understand the role of tumor perfusion in metastasis and local control.
Collapse
|
11
|
ImmunoPET, [ 64Cu]Cu-DOTA-Anti-CD33 PET-CT, Imaging of an AML Xenograft Model. Clin Cancer Res 2019; 25:7463-7474. [PMID: 31548348 DOI: 10.1158/1078-0432.ccr-19-1106] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 07/13/2019] [Accepted: 09/11/2019] [Indexed: 12/19/2022]
Abstract
PURPOSE Acute myeloid leukemia (AML) is a highly aggressive form of leukemia, which results in poor survival outcomes. Currently, diagnosis and prognosis are based on invasive single-point bone marrow biopsies (iliac crest). There is currently no AML-specific noninvasive imaging method to detect disease, including in extramedullary organs, representing an unmet clinical need. About 85% to 90% of human myeloid leukemia cells express CD33 cell surface receptors, highlighting CD33 as an ideal candidate for AML immunoPET. EXPERIMENTAL DESIGN We evaluated whether [64Cu]Cu-DOTA-anti-CD33 murine mAb can be used for immunoPET imaging of AML in a preclinical model. MicroCT was adjusted to detect spatial/anatomical details of PET activity. For translational purposes, a humanized anti-CD33 antibody was produced; we confirmed its ability to detect disease and its distribution. We reconfirmed/validated CD33 antibody-specific targeting with an antibody-drug conjugate (ADC) and radioimmunotherapy (RIT). RESULTS [64Cu]Cu-DOTA-anti-CD33-based PET-CT imaging detected CD33+ AML in mice with high sensitivity (95.65%) and specificity (100%). The CD33+ PET activity was significantly higher in specific skeletal niches [femur (P < 0.00001), tibia (P = 0.0001), humerus (P = 0.0014), and lumber spine (P < 0.00001)] in AML-bearing mice (over nonleukemic control mice). Interestingly, the hybrid PET-CT imaging showed high disease activity in the epiphysis/metaphysis of the femur, indicating regional spatial heterogeneity. Anti-CD33 therapy using newly developed humanized anti-CD33 mAb as an ADC (P = 0.02) and [225Ac]Ac-anti-CD33-RIT (P < 0.00001) significantly reduced disease burden over that of respective controls. CONCLUSIONS We have successfully developed a novel anti-CD33 immunoPET-CT-based noninvasive modality for AML and its spatial distribution, indicating a preferential skeletal niche.
Collapse
MESH Headings
- Animals
- Antibodies, Monoclonal, Humanized/pharmacokinetics
- Cell Line, Tumor
- Copper Radioisotopes/chemistry
- Disease Models, Animal
- Heterocyclic Compounds, 1-Ring/chemistry
- Immunoconjugates/pharmacokinetics
- Leukemia, Myeloid, Acute/diagnostic imaging
- Leukemia, Myeloid, Acute/drug therapy
- Leukemia, Myeloid, Acute/pathology
- Mice
- Mice, Inbred NOD
- Mice, SCID
- Positron Emission Tomography Computed Tomography/methods
- Radiopharmaceuticals/pharmacokinetics
- Sialic Acid Binding Ig-like Lectin 3/antagonists & inhibitors
- Sialic Acid Binding Ig-like Lectin 3/immunology
- Tissue Distribution
- Xenograft Model Antitumor Assays
Collapse
|
12
|
SMC1A is associated with radioresistance in prostate cancer and acts by regulating epithelial-mesenchymal transition and cancer stem-like properties. Mol Carcinog 2018; 58:113-125. [PMID: 30242889 DOI: 10.1002/mc.22913] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 08/31/2018] [Accepted: 09/16/2018] [Indexed: 12/24/2022]
Abstract
Prostate cancer is one of the most commonly diagnosed cancers and a pressing health challenge in men worldwide. Radiation therapy (RT) is widely considered a standard therapy for advanced as well as localized prostate cancer. Although this primary therapy is associated with high cancer control rates, up to one-third of patients undergoing radiation therapy becomes radio-resistant and/or has tumor-relapse/recurrence. Therefore, focus on new molecular targets and pathways is essential to develop novel radio-sensitizing agents for the effective and safe treatment of prostate cancer. Here, we describe functional studies that were performed to investigate the role of structural maintenance of chromosome-1 (SMC1A) in radioresistance of metastatic prostate cancer cells. Short hairpin RNA (shRNA) was used to suppress SMC1A in metastatic castration-resistant prostate cancer cells, DU145 and PC3. Clonogenic survival assays, Western blot, RT-PCR, and γ-H2AX staining were used to assess the effect of SMC1A knockdown on radiation sensitivity of these prostate cancer cells. We demonstrate that SMC1A is overexpressed in human prostate tumors compared to the normal adjacent tissue. SMC1A knockdown limits the clonogenic potential, epithelial-mesenchymal transition (EMT), and cancer stem-like cell (CSC) properties of DU145 and PC3 cells and enhanced efficacy of RT in these cells. Targeted inhibition of SMC1A not only plays a critical role in overcoming radio-resistance in prostate cancer cells, but also suppresses self-renewal and the tumor-propagating potential of x-irradiated cancer cells. We propose that SMC1A could be a potential molecular target for the development of novel radio-sensitizing therapeutic agents for management of radio-resistant metastatic prostate cancer.
Collapse
|
13
|
Whole-Body Distribution of Leukemia and Functional Total Marrow Irradiation Based on FLT-PET and Dual-Energy CT. Mol Imaging 2018; 16:1536012117732203. [PMID: 28948859 PMCID: PMC5624344 DOI: 10.1177/1536012117732203] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
This report describes a multimodal whole-body 3′-deoxy-3′[(18)F]-fluorothymidine positron emission tomography (FLT-PET) and dual-energy computed tomography (DECT) method to identify leukemia distribution within the bone marrow environment (BME) and to develop disease- and/or BME-specific radiation strategies. A control participant and a newly diagnosed patient with acute myeloid leukemia prior to induction chemotherapy were scanned with FLT-PET and DECT. The red marrow (RM) and yellow marrow (YM) of the BME were segmented from DECT using a basis material decomposition method. Functional total marrow irradiation (fTMI) treatment planning simulations were performed combining FLT-PET and DECT imaging to differentially target irradiation to the leukemia niche and the rest of the skeleton. Leukemia colonized both RM and YM regions, adheres to the cortical bone in the spine, and has enhanced activity in the proximal/distal femur, suggesting a potential association of leukemia with the BME. The planning target volume was reduced significantly in fTMI compared with conventional TMI. The dose to active disease (standardized uptake value >4) was increased by 2-fold, while maintaining doses to critical organs similar to those in conventional TMI. In conclusion, a hybrid system of functional–anatomical–physiological imaging can identify the spatial distribution of leukemia and will be useful to both help understand the leukemia niche and develop targeted radiation strategies.
Collapse
|
14
|
Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density. J Bone Miner Metab 2017; 35:428-436. [PMID: 27942979 PMCID: PMC5689468 DOI: 10.1007/s00774-016-0796-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Accepted: 07/24/2016] [Indexed: 11/25/2022]
Abstract
Temporal and spatial variations in bone marrow adipose tissue (MAT) can be indicative of several pathologies and confound current methods of assessing immediate changes in bone mineral remodeling. We present a novel dual-energy computed tomography (DECT) method to monitor MAT and marrow-corrected volumetric BMD (mcvBMD) throughout the body. Twenty-three cancellous skeletal sites in 20 adult female cadavers aged 40-80 years old were measured using DECT (80 and 140 kVp). vBMD was simultaneous recorded using QCT. MAT was further sampled using MRI. Thirteen lumbar vertebrae were then excised from the MRI-imaged donors and examined by microCT. After MAT correction throughout the skeleton, significant differences (p < 0.05) were found between QCT-derived vBMD and DECT-derived mcvBMD results. McvBMD was highly heterogeneous with a maximum at the posterior skull and minimum in the proximal humerus (574 and 0.7 mg/cc, respectively). BV/TV and BMC have a nearly significant correlation with mcvBMD (r = 0.545, p = 0.057 and r = 0.539, p = 0.061, respectively). MAT assessed by DECT showed a significant correlation with MRI MAT results (r = 0.881, p < 0.0001). Both DECT- and MRI-derived MAT had a significant influence on uncorrected vBMD (r = -0.86 and r = -0.818, p ≤ 0.0001, respectively). Conversely, mcvBMD had no correlation with DECT- or MRI-derived MAT (r = 0.261 and r = 0.067). DECT can be used to assess MAT while simultaneously collecting mcvBMD values at each skeletal site. MAT is heterogeneous throughout the skeleton, highly variable, and should be accounted for in longitudinal mcvBMD studies. McvBMD accurately reflects the calcified tissue in cancellous bone.
Collapse
|
15
|
Megavoltage 2D topographic imaging: An attractive alternative to megavoltage CT for the localization of breast cancer patients treated with TomoDirect. Phys Med 2017; 39:33-38. [DOI: 10.1016/j.ejmp.2017.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 06/12/2017] [Accepted: 06/14/2017] [Indexed: 11/28/2022] Open
|
16
|
Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy. Int J Radiat Oncol Biol Phys 2016; 96:688-95. [PMID: 27681766 DOI: 10.1016/j.ijrobp.2016.06.2458] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 06/22/2016] [Accepted: 06/26/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. METHODS AND MATERIALS Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. RESULTS The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. CONCLUSIONS Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.
Collapse
|
17
|
Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography. Int J Radiat Oncol Biol Phys 2016; 96:679-87. [PMID: 27681765 DOI: 10.1016/j.ijrobp.2016.06.2459] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Revised: 06/27/2016] [Accepted: 06/29/2016] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. METHODS AND MATERIALS Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. RESULTS A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). CONCLUSIONS Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.
Collapse
|
18
|
Abstract
A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during C T. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. “Hot spots” (≥150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.
Collapse
|
19
|
A mathematical model of tumor growth and its response to single irradiation. Theor Biol Med Model 2016; 13:6. [PMID: 26921069 PMCID: PMC4769590 DOI: 10.1186/s12976-016-0032-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Accepted: 02/19/2016] [Indexed: 01/16/2023] Open
Abstract
BACKGROUND Mathematical modeling of biological processes is widely used to enhance quantitative understanding of bio-medical phenomena. This quantitative knowledge can be applied in both clinical and experimental settings. Recently, many investigators began studying mathematical models of tumor response to radiation therapy. We developed a simple mathematical model to simulate the growth of tumor volume and its response to a single fraction of high dose irradiation. The modelling study may provide clinicians important insights on radiation therapy strategies through identification of biological factors significantly influencing the treatment effectiveness. METHODS We made several key assumptions of the model. Tumor volume is composed of proliferating (or dividing) cancer cells and non-dividing (or dead) cells. Tumor growth rate (or tumor volume doubling time) is proportional to the ratio of the volumes of tumor vasculature and the tumor. The vascular volume grows slower than the tumor by introducing the vascular growth retardation factor, θ. Upon irradiation, the proliferating cells gradually die over a fixed time period after irradiation. Dead cells are cleared away with cell clearance time. The model was applied to simulate pre-treatment growth and post-treatment radiation response of rat rhabdomyosarcoma tumors and metastatic brain tumors of five patients who were treated with Gamma Knife stereotactic radiosurgery (GKSRS). RESULTS By selecting appropriate model parameters, we showed the temporal variation of the tumors for both the rat experiment and the clinical GKSRS cases could be easily replicated by the simple model. Additionally, the application of our model to the GKSRS cases showed that the α-value, which is an indicator of radiation sensitivity in the LQ model, and the value of θ could be predictors of the post-treatment volume change. CONCLUSIONS The proposed model was successful in representing both the animal experimental data and the clinically observed tumor volume changes. We showed that the model can be used to find the potential biological parameters, which may be able to predict the treatment outcome. However, there is a large statistical uncertainty of the result due to the small sample size. Therefore, a future clinical study with a larger number of patients is needed to confirm the finding.
Collapse
|
20
|
Characterization of an orthovoltage biological irradiator used for radiobiological research. JOURNAL OF RADIATION RESEARCH 2015; 56:485-492. [PMID: 25694476 PMCID: PMC4426923 DOI: 10.1093/jrr/rru129] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 12/16/2014] [Accepted: 12/27/2014] [Indexed: 06/01/2023]
Abstract
Orthovoltage irradiators are routinely used to irradiate specimens and small animals in biological research. There are several reports on the characteristics of these units for small field irradiations. However, there is limited knowledge about use of these units for large fields, which are essential for emerging large-field irregular shape irradiations, namely total marrow irradiation used as a conditioning regimen for hematological malignancies. This work describes characterization of a self-contained Orthovoltage biological irradiator for large fields using measurements and Monte Carlo simulations that could be used to compute the dose for in vivo or in vitro studies for large-field irradiation using this or a similar unit. Percentage depth dose, profiles, scatter factors, and half-value layers were measured and analyzed. A Monte Carlo model of the unit was created and used to generate depth dose and profiles, as well as scatter factors. An ion chamber array was also used for profile measurements of flatness and symmetry. The output was determined according to AAPM Task Group 61 guidelines. The depth dose measurements compare well with published data for similar beams. The Monte Carlo-generated depth dose and profiles match our measured doses to within 2%. Scatter factor measurements indicate gradual variation of these factors with field size. Dose rate measured by placing the ion chamber atop the unit's steel plate or solid water indicate enhanced readings of 5 to 28% compared with those measured in air. The stability of output over a 5-year period is within 2% of the 5-year average.
Collapse
|
21
|
A phase I feasibility study of multi-modality imaging assessing rapid expansion of marrow fat and decreased bone mineral density in cancer patients. Bone 2015; 73:90-7. [PMID: 25536285 PMCID: PMC4336831 DOI: 10.1016/j.bone.2014.12.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 12/11/2014] [Accepted: 12/15/2014] [Indexed: 11/23/2022]
Abstract
PURPOSE Cancer survivors are at an increased risk for fractures, but lack of effective and economical biomarkers limits quantitative assessments of marrow fat (MF), bone mineral density (BMD) and their relation in response to cytotoxic cancer treatment. We report dual energy CT (DECT) imaging, commonly used for cancer diagnosis, treatment and surveillance, as a novel biomarker of MF and BMD. METHODS We validated DECT in pre-clinical and phase I clinical trials and verified with water-fat MRI (WF-MRI), quantitative CT (QCT) and dual-energy X-ray absorptiometry (DXA). Basis material composition framework was validated using water and small-chain alcohols simulating different components of bone marrow. Histologic validation was achieved by measuring percent adipocyte in the cadaver vertebrae and compared with DECT and WF-MRI. For a phase I trial, sixteen patients with gynecologic malignancies (treated with oophorectomy, radiotherapy or chemotherapy) underwent DECT, QCT, WF-MRI and DXA before and 12months after treatment. BMD and MF percent and distribution were quantified in the lumbar vertebrae and the right femoral neck. RESULTS Measured precision (3mg/cm(3)) was sufficient to distinguish test solutions. Adiposity in cadaver bone histology was highly correlated with MF measured using DECT and WF-MRI (r=0.80 and 0.77, respectively). In the clinical trial, DECT showed high overall correlation (r=0.77, 95% CI: 0.69, 0.83) with WF-MRI. MF increased significantly after treatment (p<0.002). Chemotherapy and radiation caused greater increases in MF than oophorectomy (p<0.032). L4 BMD decreased 14% by DECT, 20% by QCT, but only 5% by DXA (p<0.002 for all). At baseline, we observed a statistically significant inverse association between MF and BMD which was dramatically attenuated after treatment. CONCLUSION Our study demonstrated that DECT, similar to WF-MRI, can accurately measure marrow adiposity. Both imaging modalities show rapid increase in MF following cancer treatment. Our results suggest that MF and BMD cannot be used interchangeably to monitor skeletal health following cancer therapy.
Collapse
|
22
|
Radiation response of mesenchymal stem cells derived from bone marrow and human pluripotent stem cells. JOURNAL OF RADIATION RESEARCH 2015; 56:269-277. [PMID: 25425005 PMCID: PMC4380046 DOI: 10.1093/jrr/rru098] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Revised: 08/30/2014] [Accepted: 09/29/2014] [Indexed: 06/04/2023]
Abstract
Mesenchymal stem cells (MSCs) isolated from human pluripotent stem cells are comparable with bone marrow-derived MSCs in their function and immunophenotype. The purpose of this exploratory study was comparative evaluation of the radiation responses of mesenchymal stem cells derived from bone marrow- (BMMSCs) and from human embryonic stem cells (hESMSCs). BMMSCs and hESMSCs were irradiated at 0 Gy (control) to 16 Gy using a linear accelerator commonly used for cancer treatment. Cells were harvested immediately after irradiation, and at 1 and 5 days after irradiation. Cell cycle analysis, colony forming ability (CFU-F), differentiation ability, and expression of osteogenic-specific runt-related transcription factor 2 (RUNX2), adipogenic peroxisome proliferator-activated receptor gamma (PPARγ), oxidative stress-specific dismutase-1 (SOD1) and Glutathione peroxidase (GPX1) were analyzed. Irradiation arrested cell cycle progression in BMMSCs and hESMSCs. Colony formation ability of irradiated MSCs decreased in a dose-dependent manner. Irradiated hESMSCs showed higher adipogenic differentiation compared with BMMSCs, together with an increase in the adipogenic PPARγ expression. PPARγ expression was upregulated as early as 4 h after irradiation, along with the expression of SOD1. More than 70% downregulation was found in Wnt3A, Wnt4, Wnt 7A, Wnt10A and Wnt11 in BMMSCs, but not in hESMSCs. hESMSCs are highly proliferative but radiosensitive compared with BMMSCs. Increased PPARγ expression relative to RUNX2 and downregulation of Wnt ligands in irradiated MSCs suggest Wnt mediated the fate determination of irradiated MSCs.
Collapse
|
23
|
Spatial and temporal fracture pattern in breast and gynecologic cancer survivors. J Cancer 2015; 6:66-9. [PMID: 25553090 PMCID: PMC4278916 DOI: 10.7150/jca.10288] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Accepted: 10/06/2014] [Indexed: 11/10/2022] Open
Abstract
Objective(s): To assess skeletal wide fracture location and time of fracture after cancer treatment Study Design: One hundred thirty-nine women diagnosed with breast or gynecologic cancer between 2003 and 2012 that subsequently had a radiologic diagnosis of fracture were identified retrospectively using electronic medical records. Results were compared with skeletal fracture pattern previously reported for a general population. Results: Skeletal fractures in cancer patients occur throughout the entire skeleton similar to general population. The most common sites were vertebrae (16%), feet and toes (15%), ribs (12%), hands and fingers (10%), and pelvis (8%). Fracture incidence was observed starting within the first year of survivorship, and continued to after five years. The median time from cancer diagnosis to fracture varied by age (p<0.01), from a high of 3.2 years for ages 50-59 to a low of 1.2 years for patients older than 70. Conclusion: The pattern of skeletal fracture is similar between cancer survivor and general population. Contrary to general assumption, survivors can experience skeletal fracture early after cancer treatment, especially at an older age. Thus, cancer survivorship care should include assessment of early time points with improved management of cancer treatment related bone injury.
Collapse
|
24
|
Multi-institutional feasibility study of a fast patient localization method in total marrow irradiation with helical tomotherapy: a global health initiative by the international consortium of total marrow irradiation. Int J Radiat Oncol Biol Phys 2014; 91:30-8. [PMID: 25442340 DOI: 10.1016/j.ijrobp.2014.09.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 08/08/2014] [Accepted: 09/10/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE To develop, characterize, and implement a fast patient localization method for total marrow irradiation. METHODS AND MATERIALS Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. RESULTS The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial-caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. CONCLUSION Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization.
Collapse
|
25
|
Bone marrow adipose tissue is an endocrine organ that contributes to increased circulating adiponectin during caloric restriction. Cell Metab 2014; 20:368-375. [PMID: 24998914 PMCID: PMC4126847 DOI: 10.1016/j.cmet.2014.06.003] [Citation(s) in RCA: 353] [Impact Index Per Article: 35.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 12/10/2013] [Accepted: 05/12/2014] [Indexed: 10/25/2022]
Abstract
The adipocyte-derived hormone adiponectin promotes metabolic and cardiovascular health. Circulating adiponectin increases in lean states such as caloric restriction (CR), but the reasons for this paradox remain unclear. Unlike white adipose tissue (WAT), bone marrow adipose tissue (MAT) increases during CR, and both MAT and serum adiponectin increase in many other clinical conditions. Thus, we investigated whether MAT contributes to circulating adiponectin. We find that adiponectin secretion is greater from MAT than WAT. Notably, specific inhibition of MAT formation in mice results in decreased circulating adiponectin during CR despite unaltered adiponectin expression in WAT. Inhibiting MAT formation also alters skeletal muscle adaptation to CR, suggesting that MAT exerts systemic effects. Finally, we reveal that both MAT and serum adiponectin increase during cancer therapy in humans. These observations identify MAT as an endocrine organ that contributes significantly to increased serum adiponectin during CR and perhaps in other adverse states.
Collapse
|
26
|
High-throughput multiple-mouse imaging with micro-PET/CT for whole-skeleton assessment. Phys Med 2014; 30:849-53. [PMID: 24998335 DOI: 10.1016/j.ejmp.2014.06.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 06/05/2014] [Accepted: 06/09/2014] [Indexed: 10/25/2022] Open
Abstract
Recent studies have proven that skeleton-wide functional assessment is essential to comprehensively understand physiological aspects of the skeletal system. Therefore, in contrast to regional imaging studies utilizing a multiple-animal holder (mouse hotel), we attempted to develop and characterize a multiple-mouse imaging system with micro-PET/CT for high-throughput whole-skeleton assessment. Using items found in a laboratory, a simple mouse hotel that houses four mice linked with gas anesthesia was constructed. A mouse-simulating phantom was used to measure uniformity in a cross sectional area and flatness (Amax/Amin*100) along the axial, radial and tangential directions, where Amax and Amin are maximum and minimum activity concentration in the profile, respectively. Fourteen mice were used for single- or multiple-micro-PET/CT scans. NaF uptake was measured at eight skeletal sites (skull to tibia). Skeletal (18)F activities measured with mice in the mouse hotel were within 1.6 ± 4% (mean ± standard deviation) of those measured with mice in the single-mouse holder. Single-holder scanning yields slightly better uniformity and flatness over the hotel. Compared to use of the single-mouse holder, scanning with the mouse hotel reduced study time (by 65%), decreased the number of scans (four-fold), reduced cost, required less computer storage space (40%), and maximized (18)F usage. The mouse hotel allows high-throughput, quantitatively equivalent scanning compared to the single-mouse holder for micro-PET/CT imaging for whole-skeleton assessment of mice.
Collapse
|
27
|
A dual-radioisotope hybrid whole-body micro-positron emission tomography/computed tomography system reveals functional heterogeneity and early local and systemic changes following targeted radiation to the murine caudal skeleton. Calcif Tissue Int 2014; 94:544-52. [PMID: 24562595 PMCID: PMC3987955 DOI: 10.1007/s00223-014-9839-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 01/17/2014] [Indexed: 12/27/2022]
Abstract
The purpose of this study was to develop a longitudinal non-invasive functional imaging method using a dual-radioisotope hybrid micro-positron emission tomography/computed tomography (PET/CT) scanner in order to assess both the skeletal metabolic heterogeneity and the effect of localized radiation that models therapeutic cancer treatment on marrow and bone metabolism. Skeletally mature BALB/c female mice were given clinically relevant local radiation (16 Gy) to the hind limbs on day 0. Micro-PET/CT acquisition was performed serially for the same mice on days -5 and +2 with FDG and days -4 and +3 with NaF. Serum levels of pro-inflammatory cytokines were measured. Significant differences (p < 0.0001) in marrow metabolism (measured by FDG) and bone metabolism (measured by NaF) were observed among bones before radiation, which demonstrates functional heterogeneity in the marrow and mineralized bone throughout the skeleton. Radiation significantly (p < 0.0001) decreased FDG uptake but increased NaF uptake (p = 0.0314) in both irradiated and non-irradiated bones at early time points. An increase in IL-6 was observed with a significant abscopal (distant) effect on marrow and bone metabolic function. Radiation significantly decreased circulating IGF-1 (p < 0.01). Non-invasive longitudinal imaging with dual-radioisotope micro-PET/CT is feasible to investigate simultaneous changes in marrow and bone metabolic function at local and distant skeletal sites in response to focused radiation injury. Distinct local and remote changes may be affected by several cytokines activated early after local radiation exposure. This approach has the potential for longer-term studies to clarify the effects of radiation on marrow and bone.
Collapse
|
28
|
Diagnostic challenges in patients with bleeding phenotype and von Willebrand exon 28 polymorphism p.D1472H. Haemophilia 2014; 20:e211-4. [PMID: 24581275 DOI: 10.1111/hae.12384] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/10/2014] [Indexed: 11/28/2022]
Abstract
Exon 28 polymorphism p.D1472H is associated with significantly lower von Willebrand Ristocetin cofactor activity (VWF:RCoF) to von Willebrand antigen (VWF:Ag) ratio compared to normal, but has been reported as not conferring haemorrhagic risk. The impact of this polymorphism while assessing symptomatic patients for von Willebrand disease (VWD) has not been previously analysed. We retrospectively reviewed charts of children with clinically significant bleeding and abnormal VW panel who underwent VW exon 28 analysis. Twenty-three of 63 patients studied had p.D1472H. Of these 23 patients, 6 with borderline low VWF:RCo were given provisional diagnosis of VWD type 1 by treating physicians, which could be alternatively explained as due to the effect of p.D1472H. None of the patients with low VWF:RCo, decreased VWF:RCo/VWF:Ag ratio and p.D1472H had VWD type 2M mutations identified. This study illustrates the challenge in diagnosing VWD using ristocetin-based VW assay in symptomatic patients with p.D1472H.
Collapse
|
29
|
Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy. Radiat Oncol 2014; 9:34. [PMID: 24461048 PMCID: PMC3922911 DOI: 10.1186/1748-717x-9-34] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Accepted: 01/23/2014] [Indexed: 11/20/2022] Open
Abstract
Background Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the target volumes, which significantly prolongs the dose verification process. We propose a fast, simple, and informative patient-specific dose verification method which reduce dose verification time for TMI with helical tomotherapy. Methods We constructed a two-step solid water slab phantom (length 110 cm, height 8 cm, and two-step width of 30 cm and 15 cm), termed the Whole Body Phantom (WB phantom). Three ionization chambers and three EDR-2 films can be inserted to cover extended field TMI treatment delivery. Three TMI treatment plans were conducted with a TomoTherapy HiArt Planning Station and verified using the WB phantom with ion chambers and films. Three regions simulating the head and neck, thorax, and pelvis were covered in a single treatment delivery. The results were compared to those with the cheese phantom supplied by Accuray, Inc. following three treatment deliveries to cover the body from head to pelvis. Results Use of the WB phantom provided point doses or dose distributions from head and neck to femur in a single treatment delivery of TMI. Patient-specific dose verification with the WB phantom was 62% faster than with the cheese phantom. The average pass rate in gamma analysis with the criteria of a 3-mm distance-to-agreement and 3% dose differences was 94% ± 2% for the three TMI treatment plans. The differences in pass rates between the WB and cheese phantoms at the upper thorax to abdomen regions were within 2%. The calculated dose agreed with the measured dose within 3% for all points in all five cases in both the WB and cheese phantoms. Conclusions Our dose verification method with the WB phantom provides simple and rapid quality assurance without limiting dose verification information in total marrow irradiation with helical tomotherapy.
Collapse
|
30
|
Effect of radiation dose-rate on hematopoietic cell engraftment in adult zebrafish. PLoS One 2013; 8:e73745. [PMID: 24058487 PMCID: PMC3776794 DOI: 10.1371/journal.pone.0073745] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2013] [Accepted: 07/31/2013] [Indexed: 11/18/2022] Open
Abstract
Although exceptionally high radiation dose-rates are currently attaining clinical feasibility, there have been relatively few studies reporting the biological consequences of these dose-rates in hematopoietic cell transplant (HCT). In zebrafish models of HCT, preconditioning before transplant is typically achieved through radiation alone. We report the comparison of outcomes in adult zebrafish irradiated with 20 Gy at either 25 or 800 cGy/min in the context of experimental HCT. In non-transplanted irradiated fish we observed no substantial differences between dose-rate groups as assessed by fish mortality, cell death in the kidney, endogenous hematopoietic reconstitution, or gene expression levels of p53 and ddb2 (damage-specific DNA binding protein 2) in the kidney. However, following HCT, recipients conditioned with the higher dose rate showed significantly improved donor-derived engraftment at 9 days post transplant (p ≤ 0.0001), and improved engraftment persisted at 31 days post transplant. Analysis for sdf-1a expression, as well as transplant of hematopoietic cells from cxcr4b -/- zebrafish, (odysseus), cumulatively suggest that the sdf-1a/cxcr4b axis is not required of donor-derived cells for the observed dose-rate effect on engraftment. Overall, the adult zebrafish model of HCT indicates that exceptionally high radiation dose-rates can impact HCT outcome, and offers a new system for radiobiological and mechanistic interrogation of this phenomenon. Key words: Radiation dose rate, Total Marrow Irradiation (TMI), Total body irradiation (TBI), SDF-1, Zebrafish, hematopoietic cell transplant.
Collapse
|
31
|
Peripheral dose heterogeneity due to the thread effect in total marrow irradiation with helical tomotherapy. Int J Radiat Oncol Biol Phys 2013; 87:832-9. [PMID: 24011657 DOI: 10.1016/j.ijrobp.2013.07.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2013] [Revised: 07/03/2013] [Accepted: 07/15/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE To report potential dose heterogeneity leading to underdosing at different skeletal sites in total marrow irradiation (TMI) with helical tomotherapy due to the thread effect and provide possible solutions to reduce this effect. METHODS AND MATERIALS Nine cases were divided into 2 groups based on patient size, defined as maximum left-to-right arm distance (mLRD): small mLRD (≤47 cm) and large mLRD (>47 cm). TMI treatment planning was conducted by varying the pitch and modulation factor while a jaw size (5 cm) was kept fixed. Ripple amplitude, defined as the peak-to-trough dose relative to the average dose due to the thread effect, and the dose-volume histogram (DVH) parameters for 9 cases with various mLRD was analyzed in different skeletal regions at off-axis (eg, bones of the arm or femur), at the central axis (eg, vertebrae), and planning target volume (PTV), defined as the entire skeleton plus 1-cm margin. RESULTS Average ripple amplitude for a pitch of 0.430, known as one of the magic pitches that reduce thread effect, was 9.2% at 20 cm off-axis. No significant differences in DVH parameters of PTV, vertebrae, or femur were observed between small and large mLRD groups for a pitch of ≤0.287. Conversely, in the bones of the arm, average differences in the volume receiving 95% and 107% dose (V95 and V107, respectively) between large and small mLRD groups were 4.2% (P=.016) and 16% (P=.016), respectively. Strong correlations were found between mLRD and ripple amplitude (rs=.965), mLRD and V95 (rs=-.742), and mLRD and V107 (rs=.870) of bones of the arm. CONCLUSIONS Thread effect significantly influences DVH parameters in the bones of the arm for large mLRD patients. By implementing a favorable pitch value and adjusting arm position, peripheral dose heterogeneity could be reduced.
Collapse
|
32
|
Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy. Radiat Oncol 2013; 8:123. [PMID: 23688298 PMCID: PMC3679448 DOI: 10.1186/1748-717x-8-123] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2013] [Accepted: 05/10/2013] [Indexed: 01/09/2023] Open
Abstract
Background Beam-on time in Total Marrow Irradiation (TMI) delivery with helical tomotherapy is more than 30 minutes. The purpose of this study was to investigate extended time output variation in tomotherapy machine without dose servo system and its impact on the dosimetry of TMI planning. Materials and methods The calibration procedures with 1800 seconds delivery were conducted. The slab and cylindrical phantoms were used for static and rotational output variation measurements, respectively. All measurements were performed in 0.1 second interval with an Exradin A1SL ionization chamber (Standard Imaging Inc., Madison, WI, USA) connected to the tomoelectrometer supplied by the manufacture. Simulated TMI treatment planning with a slab phantom was delivered and verified with ion chamber and EDR-2 films. Results The static output variations during 30 min averaged −2.9% ± 0.2%, -3.4% ± 0.3%, and −3.4% ± 0.3% at 10 min, 20 min, and 30 min, respectively. The rotational output variations from start averaged −2.5% ± 0.7%, -3.1% ± 0.7%, and −3.5% ± 0.8% at 10 min, 20 min, and 30 min, respectively. The maximum output variation was up to 4.5%. In a TMI planning model, in which beam-on time was over 30 min, planned dose and dose measured with ion chambers in both cranial and caudal sides agreed within 3%. Film measurements in cranial and caudal sides also showed the pass rates of 97.7% and 92.2% with the criteria of 3 mm/3% in gamma analysis. Conclusion These results suggest that long TMI delivery by helical tomotherapy, even without dose servo system, does not pose a risk for significant deviations from the original treatment plan regardless of the output variation. However, very long time output variation should be checked before the first treatment.
Collapse
|
33
|
Calcium isolation from large-volume human urine samples for 41Ca analysis by accelerator mass spectrometry. Appl Radiat Isot 2013; 78:57-61. [PMID: 23672965 DOI: 10.1016/j.apradiso.2013.04.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Revised: 03/13/2013] [Accepted: 04/04/2013] [Indexed: 10/26/2022]
Abstract
Calcium oxalate precipitation is the first step in preparation of biological samples for (41)Ca analysis by accelerator mass spectrometry. A simplified protocol for large-volume human urine samples was characterized, with statistically significant increases in ion current and decreases in interference. This large-volume assay minimizes cost and effort and maximizes time after (41)Ca administration during which human samples, collected over a lifetime, provide (41)Ca:Ca ratios that are significantly above background.
Collapse
|
34
|
The influence of therapeutic radiation on the patterns of bone remodeling in ovary-intact and ovariectomized mice. Calcif Tissue Int 2013; 92:372-84. [PMID: 23314741 PMCID: PMC3595353 DOI: 10.1007/s00223-012-9688-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Accepted: 11/30/2012] [Indexed: 01/23/2023]
Abstract
Our purpose was to characterize changes in bone remodeling associated with localized radiation that models therapeutic cancer treatment in ovary-intact (I) and ovariectomized (OVX) mice and to evaluate the influence of radiation on the pattern of bone mineral remodeling. Young adult, female BALB/c mice, I and OVX, were used (n = 71). All mice were intravenously injected with 15 μCi (45)Ca. Thirty days post-(45)Ca administration, the hind limbs of 17 mice were exposed to a single dose of 16 Gy radiation (R). The time course of (45)Ca excretion, serum CTx and osteocalcin markers, and cancellous bone volume fraction (BV/TV) and cortical thickness (Ct.Th) of the distal femur were assayed. Cellular activity and dynamic histomorphometry were performed. Irradiation resulted in rapid increases in fecal (45)Ca excretion compared to control groups, indicating increased bone remodeling. CTx increased rapidly after irradiation, followed by an increase in osteocalcin concentration. BV/TV decreased in the I mice following irradiation. Ct.Th increased in the OVX groups following irradiation. I+R mice exhibited diminished osteoblast surface, osteoclast number, and mineral apposition. Our murine model showed the systemic effects (via (45)Ca excretion) and local effects (via bone microarchitecture and surface activity) of clinically relevant, therapeutic radiation exposure. The I and OVX murine models have similar (45)Ca excretion but different bone microarchitectural responses. The (45)Ca assay effectively indicates the onset and rate of systemic bone mineral remodeling, providing real-time assessment of changes in bone histomorphometric parameters. Monitoring bone health via a bone mineral marker may help to identify the appropriate time for clinical intervention to preserve skeletal integrity.
Collapse
|
35
|
Regulatory pathways associated with bone loss and bone marrow adiposity caused by aging, chemotherapy, glucocorticoid therapy and radiotherapy. AMERICAN JOURNAL OF STEM CELLS 2012; 1:205-224. [PMID: 23671809 PMCID: PMC3636730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 09/01/2012] [Accepted: 09/21/2012] [Indexed: 06/02/2023]
Abstract
The bone marrow is a complex environment that houses haematopoietic and mesenchymal cell populations and regulates bone turnover throughout life. The high proliferative capacity of these cell populations however, makes them susceptible to damage and injury, altering the steady-state of the bone marrow environment. Following cancer chemotherapy, irradiation and long-term glucocorticoid use, reduced bone and increased fat formation of marrow stromal progenitor cells results in a fatty marrow cavity, reduced bone mass and increased fracture risk. These bone and marrow defects are also observed in age-related complications such as estrogen deficiency and increased oxidative stress. Although the underlying mechanisms are yet to be clarified, recent investigations have suggested a switch in lineage commitment of bone marrow mesenchymal stem cells down the adipogenic lineage at the expense of osteogenic differentiation following such stress or injury. The Wnt/β-catenin signalling pathway is however has been recognized the key mechanism regulating stromal commitment, and its involvement in the osteogenic and adipogenic lineage commitment switch under the damaging conditions has been of great interest. This article reviews the effects of various types of stress or injury on the commitment to the adipogenic and osteogenic lineages of bone marrow stromal progenitor cells, and summarizes the roles of the Wnt/β-catenin and associated signalling pathways in the lineage commitment, switch, and recovery after damage, and as a therapeutic target.
Collapse
|
36
|
Prevention of bone growth defects, increased bone resorption and marrow adiposity with folinic acid in rats receiving long-term methotrexate. PLoS One 2012; 7:e46915. [PMID: 23071661 PMCID: PMC3465278 DOI: 10.1371/journal.pone.0046915] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2012] [Accepted: 09/06/2012] [Indexed: 12/22/2022] Open
Abstract
The underlying pathophysiology for bone growth defects in paediatric cancer patients receiving high dose methotrexate chemotherapy remains unclear and currently there are no standardized preventative treatments for patients and survivors. Using a model in young rats, we investigated damaging effects of long-term treatment with methotrexate on growth plate and metaphyseal bone, and the potential protective effects of antidote folinic acid. This study demonstrated that chronic folinic acid supplementation can prevent methotrexate-induced chondrocyte apoptosis and preserve chondrocyte columnar arrangement and number in the growth plate. In the metaphysis, folinic acid supplementation can preserve primary spongiosa heights and secondary spongiosa trabecular volume by preventing osteoblasts from undergoing apoptosis and suppressing methotrexate-induced marrow adiposity and osteoclast formation. Systemically, plasma of folinic acid supplemented rats, in comparison to plasma from rats treated with MTX alone, contained a significantly lower level of IL-1β and suppressed osteoclast formation in vitro in normal bone marrow cells. The importance of IL-1β in supporting plasma-induced osteoclast formation was confirmed as the presence of an anti-IL-1β neutralizing antibody attenuated the ability of the plasma (from MTX-treated rats) in inducing osteoclast formation. Findings from this study suggest that folinic acid supplementation during chronic methotrexate treatment can alleviate growth plate and metaphyseal damages and therefore may be potentially useful in paediatric patients who are at risk of skeletal growth suppression due to chronic methotrexate chemotherapy.
Collapse
|
37
|
Skeletal remodeling following clinically relevant radiation-induced bone damage treated with zoledronic acid. Calcif Tissue Int 2012; 90:40-9. [PMID: 22083107 DOI: 10.1007/s00223-011-9547-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Accepted: 10/26/2011] [Indexed: 10/15/2022]
Abstract
Our aim was to determine if zoledronic acid (ZA) changes (45)Ca pharmacokinetics and bone microstructure in irradiated, ovary-intact (I) and irradiated, ovariectomized mice (OVX), two groups with different patterns of skeletal damage. The hind limbs of I and OVX BALB/c mice received a single 16-Gy radiation dose, simulating pre- and postmenopausal female cancer patients undergoing radiation treatment. All I and OVX mice were radiolabeled with 15 μCi (45)Ca. Mice were treated with or without a 0.5 mg/kg injection of ZA. The time course of bone mineral remodeling was evaluated using a fecal (45)Ca assay, measured by liquid scintillation. A group of nonirradiated, intact mice were used for the longitudinal evaluation of (45)Ca biodistribution. Distal femur bone histomorphometric parameters were measured using microCT at 50 days post-ZA intervention. Most (45)Ca was incorporated into the skeleton and eliminated from the soft tissues within 3-5 days postirradiation, attaining a steady state of excretion at 25-30 days. ZA intervention in both groups resulted in a rapid decrease in fecal (45)Ca excretion. There was a significant difference in (45)Ca excretion in the OVX ± ZA (P = 0.005) group but not in the I ± ZA (P = 0.655) group. The rate of excretion of fecal (45)Ca was slower in the OVX + ZA compared to the I + ZA group (P = 0.064). (45)Ca assay is useful to monitor the time course of bone mineral remodeling after an antiresorptive intervention in irradiated mice, providing a basis to investigate bone effects of cancer therapy protocols. For equivalent doses of ZA, recovery may depend on the nature and degree of skeletal damage.
Collapse
|
38
|
Liquid scintillation based quantitative measurement of dual radioisotopes (3H and 45Ca) in biological samples for bone remodeling studies. Appl Radiat Isot 2012; 70:63-8. [PMID: 21900015 PMCID: PMC3215891 DOI: 10.1016/j.apradiso.2011.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2010] [Revised: 08/01/2011] [Accepted: 08/05/2011] [Indexed: 10/17/2022]
Abstract
Acute and prolonged bone complications associated with radiation and chemotherapy in cancer survivors underscore the importance of establishing a laboratory-based complementary dual-isotope tool to evaluate short- as well as long-term bone remodeling in an in vivo model. To address this need, a liquid scintillation dual-label method was investigated using different scintillation cocktails for quantitative measurement of (3)H-tetracycline ((3)H-TC) and (45)Ca as markers of bone turnover in mice. Individual samples were prepared over a wide range of known (45)Ca/(3)H activity ratios. Results showed that (45)Ca/(3)H activity ratios determined experimentally by the dual-label method were comparable to the known activity ratios (percentage difference ∼2%), but large variations were found in samples with (45)Ca/(3)H activity ratios in range of 2-10 (percentage difference ∼20-30%). Urine and fecal samples from mice administered with both (3)H-TC and (45)Ca were analyzed with the dual-label method. Positive correlations between (3)H and (45)Ca in urine (R=0.93) and feces (R=0.83) indicate that (3)H-TC and (45)Ca can be interchangeably used to monitor longitudinal in vivo skeletal remodeling.
Collapse
|
39
|
Development of 41Ca-based pharmacokinetic model for the study of bone remodelling in humans. Clin Pharmacokinet 2011; 50:191-9. [PMID: 21294596 DOI: 10.2165/11537840-000000000-00000] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
BACKGROUND AND OBJECTIVE Initial studies show that 41Ca may be employed as a useful diagnostic bioassay for monitoring metabolic bone disease and its treatment management. The 41Ca-based pharmacokinetic model is developed to assess its feasibility in monitoring bone disease and clinical responsiveness to therapeutic regimens. METHODS A four-compartment calcium kinetic model is developed to interpret the results of clinically measured 41Ca tracer kinetics for oral and intravenous dose. This model is extended to simulate changes in bone turnover due to osteoporosis by using Gompertzian function with and without cellular accommodation. The rate constants obtained by fitting to the experimental data on drug intervention are used to simulate the impact of strategic treatment intervention. RESULTS The present model fits well with the available experimental data on 41Ca tracer kinetics. In the simulated osteoporotic model, the negative bone balance (i.e. bone loss) reflected by 41Ca/Ca urine ratio is used to demonstrate slow/fast increase over time compared to the normal state. The cellular accommodation impact is reflected by a recovery from perturbed balance. The model's predictive ability on the impact of therapeutic intervention is verified using published experimental data. The effect of bisphosphonate intervention results in positive bone balance (i.e. bone gain). CONCLUSION The four-compartment 41Ca tracer kinetic model can be flexibly used in the interpretation of results obtained from ongoing clinical studies.
Collapse
|
40
|
Assessing the clinical utility of quantitative computed tomography with a routinely used diagnostic computed tomography scanner in a cancer center. J Clin Densitom 2011; 14:41-6. [PMID: 21295741 DOI: 10.1016/j.jocd.2010.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2009] [Revised: 02/13/2010] [Accepted: 02/14/2010] [Indexed: 11/17/2022]
Abstract
The purpose of this study was to characterize quantitative computed tomography (QCT) in our multi-detector computed tomography (MDCT) scanner with regard to the influence of the QCT phantom on dose and the influence of varying mA and CIRS phantom size on bone mineral density (BMD) measurements. We accomplish this by scanning a commercially available QCT phantom and a corresponding quality assurance phantom. To assess the feasibility of having the QCT phantom in place while patients are being scanned, we measured radiation dose difference in a CT body phantom with and without the QCT phantom on the CT table and also, with and without the use of dose modulation programs. We also analyzed reconstructed QCT phantom images with the manufacturer's software to measure BMD. Although patient characteristics may be different, leading to different mA values, the influence of the QCT phantom on the dose to patients was minimal when compared with doses measured without the phantom in place. Average BMD measurements were not significantly affected by varying mA, for a fixed-size phantom. The average BMD exhibited a weak dependence on computerized imaging reference systems (CIRS) torso phantom size, with a propensity for decreasing BMD with increasing size. Measurement precision was unaffected by varying CIRS size. Having the ability to measure bone density as part of the routine management of cancer patients, with no added cost, time, or radiation dose, will allow for the prospective evaluation of bone mineral changes. We believe that this ability will facilitate the detection of abnormal bone loss and will lead to better management of this loss and, thus, reduce the complications and associated morbidity in these cancer survivors.
Collapse
|
41
|
Longitudinal assessment of bone loss from diagnostic computed tomography scans in gynecologic cancer patients treated with chemotherapy and radiation. Am J Obstet Gynecol 2010; 203:353.e1-7. [PMID: 20684943 DOI: 10.1016/j.ajog.2010.06.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2009] [Revised: 03/17/2010] [Accepted: 06/01/2010] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The objective of the study was to measure the volumetric bone mineral density (vBMD) using diagnostic computed tomography scans in gynecologic oncology patients. STUDY DESIGN In a retrospective study, spine and femoral neck (FN) vBMD was measured for 1 year in 40 patients receiving chemotherapy or radiation. RESULTS There is significant bone loss after chemotherapy, radiation, and a combination of radiation and chemotherapy (P = .0211). In 1 year, the percent reduction in vBMD (±SE) at L1-L2 spine and the FN was a 15.9% (±5.67) and 10.4% (±4.06) in chemotherapy; 11% (±5.68) and 15.8% (±2.56) in radiation; and 21.0% (±7.03) and 3.6% (±3.3.7) in the combined therapy group. Bone loss was evident immediately after treatment and persisted or worsened in most women. CONCLUSION Gynecologic cancer patients treated with chemotherapy or radiation experience immediate and prolonged bone loss; thus, pre- and posttreatment monitoring of bone loss is important in these patients.
Collapse
|
42
|
Assessing prostate, bladder and rectal doses during image guided radiation therapy--need for plan adaptation? J Appl Clin Med Phys 2009; 10:56-74. [PMID: 19692971 PMCID: PMC5720560 DOI: 10.1120/jacmp.v10i3.2883] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2008] [Revised: 04/30/2009] [Accepted: 04/27/2009] [Indexed: 11/23/2022] Open
Abstract
The primary application of Image‐Guided Radiotherapy (IGRT) in the treatment of localized prostate cancer has been to assist precise dose delivery to the tumor. With the ability to use in‐room Computed Tomography (CT) imaging modalities, the prostate, bladder and rectum can be imaged before each treatment and the actual doses delivered to these organs can be tracked using anatomy of the day. This study evaluates the dosimetric uncertainties caused by interfraction organ variation during IGRT for 10 patients using kilovoltage cone beam CT (kvCBCT) on the Elekta Synergy system and megavoltage CT (MVCT) on the TomoTherapy Hi·Art System. The actual delivered doses to the prostate, bladder and rectum were based on dose recomputation using CT anatomy of the day. The feasibility of dose calculation accuracy in kvCBCT images from the Elekta Synergy system was investigated using the ComTom phantom. Additionally, low contrast resolution, image uniformity, and spatial resolution between the three imaging modalities of kilovoltage CT (kvCT), kvCBCT and MVCT images, were quantitatively evaluated using the Catphan 600 phantom. The Planned Adaptive software was used on the TomoTherapy Hi·Art system to construct a cumulative Dose Volume Histogram (DVH), incorporating anatomical information provided by the daily MVCT scans. The cumulative DVH was examined to identify large deviation (10% or greater) between the planned and delivered mean doses. The study proposes a framework that applies the cumulative DVH to evaluate and adapt plans that are based on actual delivered doses. Due to the large deviation in CT number (›300 HU) between the kvCBCT images and the kvCT, a direct dose recomputation on the kvCBCT images from the Elekta Synergy system was found to be inaccurate. The maximum deviation to the prostate was only 2.7% in our kvCBCT study, when compared to the daily prescribed dose. However, there was a large daily variation in rectum and bladder doses based on the anatomy of the day. The maximum variation in rectum and bladder volumes receiving the percentage of prescribed dose was 12% and 40%, respectively. We have shown that by using Planned Adaptive software on the TomoTherapy Hi·Art system, plans can be adapted based on the image feedback from daily MVCT scans to allow the actual delivered doses to closely track the original planned doses. PACS number: 87.53.Tf
Collapse
|
43
|
Platelet adhesion to multimerin 1 in vitro: influences of platelet membrane receptors, von Willebrand factor and shear. J Thromb Haemost 2009; 7:685-92. [PMID: 19175495 DOI: 10.1111/j.1538-7836.2009.03284.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Multimerin 1 (MMRN1) is a large, homopolymeric adhesive protein, stored in platelets and endothelium, that when released, binds to activated platelets, endothelial cells and the extracellular matrix. OBJECTIVES The goals of our study were to determine if (i) MMRN1 supports adhesion of resting and/or activated platelets under conditions of blood flow, and (ii) if MMRN1 enhances platelet adhesion to types I and III collagen. PATIENTS/METHODS Platelet adhesion was evaluated using protein-coated microcapillaries, with or without added adhesive proteins and receptor antibodies. Platelets from healthy controls, Glanzmann thrombasthenia (GT) and severe von Willebrand factor (VWF)-deficient donors were tested. RESULTS MMRN1 supported the adhesion of activated, but not resting, washed platelets over a wide range of shear rates. At low shear (150 s(-1)), this adhesion was supported by integrins alphavbeta3 and glycoprotein (GP) Ibalpha but it did not require integrins alphaIIbbeta3 or VWF. At high shear (1500 s(-1)), adhesion to MMRN1 was supported by beta3 integrin-independent mechanisms, involving GPIbalpha and VWF, that did not require platelet activation when VWF was perfused over MMRN1 prior to platelets. MMRN1 bound to types I and III collagen, independent of VWF, however, its enhancing effects on platelet adhesion to collagen at high shear were VWF dependent. CONCLUSIONS MMRN1 supports platelet adhesion by VWF-dependent and -independent mechanisms that vary by flow rate. Additionally, MMRN1 binds to, and enhances, platelet adhesion to collagen. These findings suggest that MMRN1 could function as an adhesive ligand that promotes platelet adhesion at sites of vascular injury.
Collapse
|
44
|
Multimodality image guided total marrow irradiation and verification of the dose delivered to the lung, PTV, and thoracic bone in a patient: a case study. Technol Cancer Res Treat 2009; 8:23-8. [PMID: 19166239 DOI: 10.1177/153303460900800104] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This work reports our initial experience using multimodality image guidance to improve total marrow irradiation (TMI) using helical tomotherapy. We also monitored the details of the treatment delivery to glean information necessary for the implementation of future adaptive processes. A patient with metastatic Ewing's sarcoma underwent MRI, and bone scan imaging prior to TMI. A whole body kilovoltage CT (kVCT) scan was obtained for intensity modulated TMI treatment planning, including a boost treatment to areas of bony involvement. The delivered dose was estimated by using MVCT images from the helical tomotherapy treatment unit, compared to the expected dose distributions mapped onto the kVCT images. Clinical concerns regarding patient treatment and dosimetric uncertainties were also evaluated. A small fraction of thoracic bone volume received lower radiation dose than the prescribed dose. Reconstructed planned treatment volume (PTV) and the dose delivered to the lung were identical to planned dose. Bone scan imaging had a higher sensitivity for detecting skeletal metastasis compared to MR imaging. However the bone scan lacked sufficient specificity in three dimensions to be useful for planning conformal radiation boost treatments. Inclusion of appropriate imaging modalities improves detection of metastases, which allows the possibility of a radiation dose boost to metastases during TMI. Conformal intensity modulated radiation therapy via helical tomotherapy permitted radiation delivery to metastases in the skull with reduced dose to brain in conjunction with TMI. While TMI reduces irradiation to the lungs, onboard megavoltage computed tomography (MVCT) to verify accurate volumetric dose coverage to marrow-containing thoracic bones may be essential for successful conformal TMI treatment.
Collapse
|
45
|
On weak symmetries of trans-Sasakian manifolds. PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES 2009. [DOI: 10.3176/proc.2009.4.03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
46
|
Necrotizing leukoencephalopathy following CHOP chemotherapy. Leuk Res 2008; 32:1611-4. [PMID: 18378307 DOI: 10.1016/j.leukres.2008.02.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2007] [Revised: 02/15/2008] [Accepted: 02/17/2008] [Indexed: 11/28/2022]
Abstract
Toxic leukoencephalopathy syndromes are rare disorders of cerebral injury characterized by changes in the white matter and accompanying neurologic dysfunction. They have been reported in association with a variety of clinical etiologies, most commonly including severe hypertension, cranial irradiation, and environmental toxins. However, they have also been described in conjunction with immunosuppressive and chemotherapeutic agents. There has been one case of fatal leukoencephalopathy reported following CHOP chemotherapy for non-Hodgkin lymphoma. We report a second case of fatal necrotizing leukoencephalopathy following the administration of CHOP chemotherapy.
Collapse
|
47
|
Helical tomotherapy targeting total bone marrow - first clinical experience at the University of Minnesota. Acta Oncol 2007; 46:250-5. [PMID: 17453378 DOI: 10.1080/02841860601042449] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
48
|
SU-FF-J-109: Conformal Prostate Treatment - a Closer Look at Dose Delivery Uncertainty and Adaptive Options. Med Phys 2007. [DOI: 10.1118/1.2760614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
49
|
Abstract
Studies in white populations have confirmed advanced age as a risk factor for cutaneous melanoma, but in nonwhite populations, its role is less clear. To clarify a possible association in our local population, comprising 94.9% Chinese, a retrospective epidemiological study of 20 years of data on cutaneous melanoma between 1983 and 2002 from a central cancer registry in Hong Kong was conducted. There were 989 new cases and 378 death cases registered, and analysis showed that both the incidence and mortality rate of cutaneous melanoma increase with increasing age. Advanced age is thus confirmed as a risk factor for cutaneous melanoma in our local population. In an ageing population, the estimated future incidence and mortality rate of cutaneous melanoma are likely to increase.
Collapse
|
50
|
Abstract
Helical tomotherapy radiation therapy units, due to their particular design and differences from a traditional linear accelerator, require different procedures by which to perform routine quality assurance (QA). One of the principal QA tasks that should be performed daily on any radiation therapy equipment is the output constancy check. The daily output check on a Hi-Art TomoTherapy unit is commonly performed utilizing ionization chambers placed inside a solid water phantom. This provides a good check of output at one point, but does not give any information on either energy or symmetry of the beam, unless more than one point is measured. This also has the added disadvantage that it has to be done by the physics staff. To address these issues, and to simplify the process, such that it can be performed by radiation therapists, we investigated the use of a commercially available daily QA device to perform this task. The use of this device simplifies the task of daily output constancy checks and eliminates the need for continued physics involvement. This device can also be used to monitor the constancy of beam energy and cone profile and can potentially be used to detect gross errors in the couch movement or laser alignment.