1
|
Three-dimensional corrective osteotomy for cubitus varus deformity using patient-matched instruments. JSES Int 2024; 8:646-653. [PMID: 38707552 PMCID: PMC11064714 DOI: 10.1016/j.jseint.2024.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/07/2024] Open
Abstract
Background Various methods of two or three-dimensional (3D) corrective osteotomy for cubitus varus deformity have been reported. However, whether 3D correction of cubitus varus deformity is necessary is controversial because of technical difficulties and surgical complications. This study introduced 3D simulations and printing technology for corrective osteotomy against cubitus varus deformities. Moreover, recent studies on the application of these technologies were reviewed. Methods The amount of 3D deformity was calculated based on the difference in 3D shape between the affected side and the contralateral normal side. Patient-matched instruments were created to perform the actual surgery as simulated. Further, a 3D corrective osteotomy was performed using patient-matched instruments for cubitus varus deformity in pediatric and adolescent patients. The humerus-elbow-wrist angle, tilting angle, and elbow ranges of motion were evaluated. Results Humerus-elbow-wrist angle and tilting angle were corrected from -21° to 14° and from 30° to 43°, respectively, in the pediatric patient and from -18° to 10° and from 20° to 40°, respectively, in the adolescent patient. The elbow flexion and extension angles changed from 130° to 140° and from 20° to 10°, respectively, in the pediatric patient and from 120° to 130° and from 15° to 0°, respectively, in the adolescent patient. Conclusion The 3D computer simulations and the use of patient-matched instruments for cubitus varus deformity are reliable and can facilitate an accurate and safe correction. These technologies can simplify the complexity of 3D surgical procedures and contribute to the standardization of treatment for cubitus varus deformity.
Collapse
|
2
|
Reproduction of forearm rotation dynamic using intensity-based biplane 2D-3D registration matching method. Sci Rep 2024; 14:5518. [PMID: 38448504 PMCID: PMC10918057 DOI: 10.1038/s41598-024-55956-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 02/29/2024] [Indexed: 03/08/2024] Open
Abstract
This study aimed to reproduce and analyse the in vivo dynamic rotational motion of the forearm and to clarify forearm motion involvement and the anatomical function of the interosseous membrane (IOM). The dynamic forearm rotational motion of the radius and ulna was analysed in vivo using a novel image-matching method based on fluoroscopic and computed tomography images for intensity-based biplane two-dimensional-three-dimensional registration. Twenty upper limbs from 10 healthy volunteers were included in this study. The mean range of forearm rotation was 150 ± 26° for dominant hands and 151 ± 18° for non-dominant hands, with no significant difference observed between the two. The radius was most proximal to the maximum pronation relative to the ulna, moved distally toward 60% of the rotation range from maximum pronation, and again proximally toward supination. The mean axial translation of the radius relative to the ulna during forearm rotation was 1.8 ± 0.8 and 1.8 ± 0.9 mm for dominant and non-dominant hands, respectively. The lengths of the IOM components, excluding the central band (CB), changed rotation. The transverse CB length was maximal at approximately 50% of the rotation range from maximum pronation. Summarily, this study describes a detailed method for evaluating in vivo dynamic forearm motion and provides valuable insights into forearm kinematics and IOM function.
Collapse
|
3
|
Neurotropin® accelerates peripheral nerve regeneration in a rat sciatic nerve crush injury model. J Orthop Sci 2024; 29:653-659. [PMID: 36858838 DOI: 10.1016/j.jos.2023.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 03/03/2023]
Abstract
BACKGROUND Peripheral nerve injuries are common and serious conditions. The effect of Neurotropin® (NTP), a nonprotein extract derived from the inflamed skin of rabbits inoculated with vaccinia virus, on peripheral nerve regeneration has not been fully elucidated. However, it has analgesic properties via the activation of descending pain inhibitory systems. Therefore, the current study aimed to determine the effects of NTP on peripheral nerve regeneration. METHODS We examined axonal outgrowth of dorsal root ganglion (DRG) neurons using immunocytochemistry in vitro. In addition, nerve regeneration was evaluated functionally, electrophysiologically, and histologically in a rat sciatic nerve crush injury model in vivo. Furthermore, gene expression of neurotrophic factors in the injured sciatic nerves and DRGs was evaluated. RESULTS In the dorsal root ganglion neurons in vitro, NTP promoted axonal outgrowth at a concentration of 10 mNU/mL. Moreover, the systemic administration of NTP contributed to the recovery of motor and sensory function at 2 weeks, and of sensory function, nerve conduction velocity, terminal latency, and axon-remyelination 4 weeks after sciatic nerve injury. In the gene expression assessment, insulin-like growth factor 1 and vascular endothelial growth factor expressions were increased in the injured sciatic nerve 2 days postoperatively. CONCLUSIONS Therefore, NTP might be effective in not only treating chronic pain but also promoting peripheral nerve regeneration after injury.
Collapse
|
4
|
Acceptable range of forearm deformity derived from relation to three-dimensional analysis and clinical impairments. J Orthop Res 2024. [PMID: 38414415 DOI: 10.1002/jor.25805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 12/02/2023] [Accepted: 01/19/2024] [Indexed: 02/29/2024]
Abstract
This study aimed to investigate deformity patterns that cause clinical impairments and determine the acceptable range of deformity in the treatment of forearm diaphyseal fractures. A three-dimensional (3D) deformity analysis based on computed bone models was performed on 39 patients with malunited diaphyseal both-bone forearm fractures to investigate the 3D deformity patterns of the radius and ulna at the fracture location and the relationship between 3D deformity and clinical impairments. Clinical impairments were evaluated using forearm motion deficit. Cutoff values of forearm deformities were calculated by performing receiver operating characteristic analysis using the deformity angle and the limited forearm rotation range of motion (less than 50° of pronation or supination) resulting in activities of daily living (ADL) impairment as variables. The extension, varus, and pronation deformities most commonly occurred in the radius, whereas the extension deformity was commonly observed in the ulna. A positive correlation was observed between pronation deficit and extension deformity of the radius (R = 0.41) and between supination deficit and pronation deformity of the ulna (R = 0.44). In contrast, a negative correlation was observed between pronation deficit and pronation deformity of the radius (R = -0.44) and between pronation deficit and pronation deformity of the ulna (R = -0.51). To minimize ADL impairment, radial extension deformity should be <18.4°, radial rotation deformity <12.8°, and ulnar rotation deformity <16.6°. The deformities in the sagittal and axial planes of the radius and in the axial plane of the ulna were responsible for the limited forearm rotation.
Collapse
|
5
|
The effect of forearm rotation on the bone mineral density measurements of the distal radius. J Bone Miner Metab 2024; 42:37-46. [PMID: 38057601 DOI: 10.1007/s00774-023-01473-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 10/09/2023] [Indexed: 12/08/2023]
Abstract
INTRODUCTION Forearm dual-energy X-ray absorptiometry (DXA) is often performed in clinics where central DXA is unavailable. Accurate bone mineral density (BMD) measurement is crucial for clinical assessment. Forearm rotation can affect BMD measurements, but this effect remains uncertain. Thus, we aimed to conduct a simulation study using CT images to clarify the effect of forearm rotation on BMD measurements. MATERIALS AND METHODS Forearm CT images of 60 women were analyzed. BMD was measured at the total, ultra-distal (UD), mid-distal (MD), and distal 33% radius regions with the radius located at the neutral position using digitally reconstructed radiographs generated from CT images. Then, the rotation was altered from - 30° to 30° (supination set as positive) with a one-degree increment, and the percent BMD changes from the neutral position were quantified for all regions at each angle for each patient. RESULTS The maximum mean BMD changes were 5.8%, 7.0%, 6.2%, and 7.2% for the total, UD, MD, and distal 33% radius regions, respectively. The analysis of the absolute values of the percent BMD changes from the neutral position showed that BMD changes of all patients remained within 2% when the rotation was between - 5° and 7° for the total region, between - 3° and 2° for the UD region, between - 4° and 3° for the MD region, and between - 3° and 1° for the distal 33% radius region. CONCLUSION Subtle rotational changes affected the BMD measurement of each region. The results showed the importance of forearm positioning when measuring the distal radius BMD.
Collapse
|
6
|
Study of Reliability and Validity of the Load Cell-Type Hand Dynamometer Compared to the Jamar Dynamometer and the Number of Reliable Grip Strength Measurements. J Hand Surg Asian Pac Vol 2023; 28:562-572. [PMID: 37881817 DOI: 10.1142/s2424835523500601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
Background: Standardised measurement protocols for grip strength remained unclear due to variations in values depending on the device and measurement method. The load cell hand dynamometer has recently been developed. This study aims to investigate the reliability of the load cell dynamometer by comparing it to the Jamar dynamometer, which is considered the gold standard, and to identify a reliable and practical measurement method. Methods: This study included 80 healthy hospital workers (mean age of 40.1 years). All measurements were performed seated, with the elbow flexed 90° and the grip span at the second handle (approximately 50 mm) for the Jamar dynamometer, and with the elbow extended and the grip span fixed at 55 mm for the load cell dynamometer. Grip strength was measured three times on each hand using two dynamometers, and the same tests were repeated on different days. Test-retest reliability, the association between the two devices and the agreement between the two measurement methods were assessed using the intraclass correlation coefficient (ICC), Pearson correlation and the Bland-Altman analysis. Results: The ICC of the one measurement was lower than that of three measurements for both dynamometers, but was above 0.858 in all groups, indicating sufficient reliability with one-time measurement. Additionally, the ICC for different days revealed good reliability (Jamar: >0.830, load cell: >0.772). The load cell dynamometer showed significantly lower values in all measurements despite the excellent correlation (r > 0.70) and the agreement between the two dynamometers. Conclusions: This study revealed sufficient reliability of the load cell dynamometer with the standardised measurement method, but it should be noted the lower values compared to the Jamar dynamometer. Additionally, one-time measurement reliability is adequate for practical use by standardising the measurement methods for both dynamometers. Level of Evidence: Level III (Diagnostic).
Collapse
|
7
|
Quantitative 3-D CT Demonstrates Distal Row Pronation and Translation and Radiolunate Arthritis in the SNAC Wrist. J Bone Joint Surg Am 2023; 105:1329-1337. [PMID: 37471563 DOI: 10.2106/jbjs.22.01350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
BACKGROUND In scaphoid nonunion advanced collapse (SNAC) wrist arthritis, we analyzed the 3-dimensional (3-D) deformity patterns of carpal alignment secondary to scaphoid nonunion and quantified subchondral arthritis by investigating alterations in bone density. METHODS We constructed 3-D models of the carpal bones and radius from 51 patients with scaphoid nonunion (nonunion group) and 50 healthy controls (control group). We quantified the differences in 3-D geometric position of the distal carpal row relative to the distal radius in SNAC wrists versus controls. In addition, we assessed the bone density of anatomic regions of interest in the radiocarpal and capitolunate joints relative to the pisiform bone density to characterize degenerative changes in SNAC wrists. RESULTS The distal carpal row pronated by a difference of 14° (7.2° versus -6.7°; p < 0.001), deviated ulnarly by a difference of 19° (7.7° versus -11.2°; p < 0.001), shifted dorsally by a difference of 17% of the dorsovolar width of the distal radius (21.0% versus 4.4%; p < 0.001), shifted radially by a difference of 8% of the radioulnar width of the distal radius (13.2% versus 5.3%; p < 0.001), and migrated proximally by a difference of 12% of the lunate height (96.3% versus 108.8%; p < 0.001) in the nonunion group compared with the control group. Additionally, it was found that bone density was greater at the capitolunate joint (capitate head: 140.4% versus 123.7%; p < 0.001; distal lunate: 159.9% versus 146.3%; p < 0.001), the radial styloid (157.0% versus 136.3%; p < 0.001), and the radiolunate joint (proximal lunate: 134.8% versus 122.7%; p < 0.001; lunate fossa: 158.6% versus 148.1%; p = 0.005) in the nonunion group compared with the control group. CONCLUSIONS Scaphoid nonunion exhibited a unique deformity pattern and alteration in bone-density distributions. The distal carpal row not only shifted dorsally and migrated proximally but also pronated, deviated ulnarly, and shifted radially. Bone density was greater at the capitolunate joint, the radial styloid, and surprisingly, the radiolunate joint. Our findings give insight into the natural history and progression of arthritis of the SNAC wrist. Additionally, future studies may give insight into whether successful treatment of scaphoid nonunion arrests the progression of arthritis. LEVEL OF EVIDENCE Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
8
|
Non‐invasive transcriptomic analysis using
mRNAs
in skin surface lipids obtained from children with mild‐to‐moderate atopic dermatitis. J Eur Acad Dermatol Venereol 2022; 36:1477-1485. [PMID: 35462437 PMCID: PMC9545805 DOI: 10.1111/jdv.18173] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 03/23/2022] [Indexed: 11/29/2022]
Abstract
Background Specimens for analysing the molecular pathology of skin disease are generally obtained through invasive methods, such as biopsy. However, less burdensome methods are desirable for paediatric patients. We recently established a method that comprehensively analyses RNA present in sebum (skin surface lipid–RNAs: SSL‐RNAs) using a next‐generation sequencer. Using this method, biological information can be obtained from the skin in a completely non‐invasive manner. Objectives To verify the applicability of the SSL‐RNA method for analysis of paediatric skin and analyse the molecular pathology of mild‐to‐moderate atopic dermatitis (AD) in children. Methods We collected sebum specimens from the whole faces of 23 healthy children and 16 children with mild‐to‐moderate AD (eczema area and severity index (EASI) score: 5.9 ± 2.6) ranging in age from 6 months to 5 years, using an oil‐blotting film. We then extracted SSL‐RNAs from the samples and performed an AmpliSeq transcriptomic analysis. Results The expressions of genes related to keratinization (LCE, PSORS1C2, IVL and KRT17), triglyceride synthesis and storage (PLIN2, DGAT2 and CIDEA), wax synthesis (FAR2), ceramide synthesis (GBA2, SMPD3 and SPTLC3), antimicrobial peptides (DEFB1) and intercellular adhesion (CDSN), all of which are related to the skin barrier, are lower in children with AD than in healthy children. The children with AD also have higher expression of CCL17, a Th2‐cytokine and an increased Th2‐immune response as demonstrated by a gene set variation analysis. Moreover, KRT17 and CCL17 expression levels are significantly correlated with the EASI score. Conclusions Molecular changes associated with abnormal immune responses and the epidermal barrier in children with mild‐to‐moderate AD can be determined using the SSL‐RNA method. This non‐invasive method could therefore be a useful means for understanding the molecular pathology of paediatric AD.
Collapse
|
9
|
Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures. J Hand Surg Am 2022; 47:389.e1-389.e13. [PMID: 34158207 DOI: 10.1016/j.jhsa.2021.05.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 03/19/2021] [Accepted: 05/12/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE This study aimed to measure the angles between the screw and plate in 16 commercially available volar locking plates (VLPs) to determine the fixable intra-articular fragment size. METHODS Ulnar orientation angles (axial plane) and elevation angles (sagittal plane) between the distal ulnar screw and plate were measured for 14 fixed-angle VLPs and 2 variable-angle VLPs. Each VLP was simulated by 2 surgeons to sit distally and ulnarly in 10 normal distal radius models. The distance between the screw and distal/ulnar end of the distal radius on both the volar and dorsal sides, designated as the longitudinal/lateral distance, was measured to identify the fixable size of the 2 intra-articular fragments: volar lunate fragment and dorsoulnar fragment. Relationships between the ulnar orientation angle and dorsal-side lateral length as well as the elevation angle and dorsal-side longitudinal distance were analyzed. RESULTS The ulnar orientation and elevation angles ranged from 6.5° to 16.9° and -5.8° to 34.3°, respectively, for fixed-angle VLPs and -12.5° to 32.2° and 3.1° to 42.1°, respectively, for variable-angle VLPs. The minimal longitudinal distances on the volar side with the fixed- and variable-angle VLPs were 4.3-10.9 mm and 5.8-5.9 mm, respectively. On the dorsal side, the lateral distance negatively correlated with the ulnar orientation angle (R = -0.74), and the longitudinal distance negatively correlated with the elevation angle (R = -0.89). CONCLUSIONS The Depuy Synthes variable-angle VLP provides an advantage for fixating small intra-articular fragments. For fixed-angle VLPs, the Mizuho VLP provides an advantage for fixating small volar lunate fragments. A narrow dorsoulnar fragment can be fixated using a plate with a large ulnar orientation angle, such as the Zimmer Biomet or Mizuho VLP. CLINICAL RELEVANCE The ability of each individual commercially available plate to capture specific intra-articular fragments should be known.
Collapse
|
10
|
Arthroscopic Debridement of Elbow Osteoarthritis Using CT-Based Computer-Aided Navigation Systems Is Accurate. Arthrosc Sports Med Rehabil 2021; 3:e1687-e1696. [PMID: 34977621 PMCID: PMC8689228 DOI: 10.1016/j.asmr.2021.07.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 07/25/2021] [Indexed: 11/17/2022] Open
|
11
|
Artificial intelligence to diagnosis distal radius fracture using biplane plain X-rays. J Orthop Surg Res 2021; 16:694. [PMID: 34823550 PMCID: PMC8620959 DOI: 10.1186/s13018-021-02845-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 11/15/2021] [Indexed: 11/13/2022] Open
Abstract
Background Although the automatic diagnosis of fractures using artificial intelligence (AI) has recently been reported to be more accurate than those by orthopedics specialists, big data with at least 1000 images or more are required for deep learning of the convolutional neural network (CNN) to improve diagnostic accuracy. The aim of this study was to develop an AI system capable of diagnosing distal radius fractures with high accuracy even when learning with relatively small data by learning to use bi-planar X-rays images. Methods VGG16, a learned image recognition model, was used as the CNN. It was modified into a network with two output layers to identify the fractures in plain X-ray images. We augmented 369 plain X-ray anteroposterior images and 360 lateral images of distal radius fractures, as well as 129 anteroposterior images and 125 lateral images of normal wrists to conduct training and diagnostic tests. Similarly, diagnostic tests for fractures of the styloid process of the ulna were conducted using 189 plain X-ray anteroposterior images of fractures and 302 images of the normal styloid process. The distal radius fracture is determined by entering an anteroposterior image of the wrist for testing into the trained AI. If it identifies a fracture, it is diagnosed as the same. However, if the anteroposterior image is determined as normal, the lateral image of the same patient is entered. If a fracture is identified, the final diagnosis is fracture; if the lateral image is identified as normal, the final diagnosis is normal. Results The diagnostic accuracy of distal radius fractures and fractures of the styloid process of the ulna were 98.0 ± 1.6% and 91.1 ± 2.5%, respectively. The areas under the receiver operating characteristic curve were 0.991 {n = 540; 95% confidence interval (CI), 0.984–0.999} and 0.956 (n = 450; 95% CI 0.938–0.973). Conclusions Our method resulted in a good diagnostic rate, even when using a relatively small amount of data.
Collapse
|
12
|
Gender differences in the impact of plasma xanthine oxidoreductase activity on coronary artery spasm. Eur Heart J 2021. [DOI: 10.1093/eurheartj/ehab724.1304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
It has been reported that decreased nitric oxide bioavailability due to increased reactive oxygen species (ROS) is one of the most important causes of coronary artery spasm (CAS). Xanthine oxidoreductase (XOR) is the rate-limiting enzyme for uric acid (UA) production and plays a pivotal role in generating ROS. It was reported that the gender differences exist in the impact of serum UA levels on cardiovascular risks. We previously demonstrated that increased plasma XOR activity is significantly associated with the incidence of CAS. However, the gender differences in the impact of plasma XOR activity on CAS remain unclear.
Purpose
The aim of this study was to examine the gender differences in the clinical impact of plasma XOR activity on CAS.
Methods
We investigated plasma XOR activity in 132 patients suspected for CAS (male, n=78; female, n=54), and underwent intracoronary acetylcholine provocation test. XOR activity assay was performed using stable isotope-labeled substrate and liquid chromatography-triple quadrupole mass spectrometry. Provoked CAS was defined as total or subtotal occlusion (≥90%) with accompanying symptoms of chest pain and/or ischemic ST-segment changes on the electrocardiogram. We excluded the patients who had significant coronary artery stenosis (≥50%) and/or were taking XOR inhibitors.
Results
Plasma XOR activity was significantly lower in female compared with male patients (30.3 pmol/h/mL, interquartile range (IQR) 22.8–42.7 vs. 51.7 pmol/h/mL, IQR 34.7–101.8; P<0.001). CAS was provoked in 36 male patients and 17 female patients, and they each had significantly higher plasma XOR activity compared with those without, respectively. Multivariate logistic regression analysis showed that plasma XOR activity was independently associated with the incidence of CAS in both genders after adjustment for confounding factors. The optimal cut-off values for predicting CAS were lower in female than those in male patients (52.3 vs. 91.6 pmol/h/mL). Multivariate analysis demonstrated that female patients with high XOR activity (≥52.3 pmol/h/mL; odds ratio [OR] 22.6, P<0.001) exhibited a higher incidence of CAS compared with that in male patients (≥91.6 pmol/h/mL; OR 8.2, P<0.001).
Conclusions
Plasma XOR activity was an independent predictor for the incidence of CAS in both genders. The impact of plasma XOR activity on CAS was stronger in female patients than in male patients.
Funding Acknowledgement
Type of funding sources: None. Figure 1Figure 2
Collapse
|
13
|
Comparison of tendon-bone healing between a newly developed ultrasound device and the conventional metallic drill in a rabbit MCL reconstruction model. J Orthop Sci 2021; 26:908-914. [PMID: 32928611 DOI: 10.1016/j.jos.2020.07.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 07/14/2020] [Accepted: 07/31/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Ligament reconstructive surgeries demand tunnel creation using an over-drilling technique, though this technique has some problems such as metallic particle liberation or difficulties in tunnel creation other than circular cross-section. Recently, a new ultrasound (US) device for bone excavation to overcome these problems was developed. This study aimed to compare the tendon-bone healing in tunnels created using the new US device to that created using the conventional drill in a rabbit model. METHODS A total of 72 rabbits underwent a reconstruction for the anterior half of the medial collateral ligament (MCL) using a half of the patellar tendon. For the femoral tunnel creation, a new US device was used in 36 rabbits (US group), while a conventional metallic drill was used for the remaining 36 rabbits (DR group). At 4, 8, and 12 weeks postoperatively, biomechanical (n = 10) and histological (n = 2) evaluations were performed. RESULTS The ultimate failure load was almost equivalent between the US and DR groups at each period (US/DR; 4 weeks, 50.0 ± 12.8 N/43.4 ± 18.9 N, p = 0.62; 8 weeks, 78.6 ± 11.5 N/77.3 ± 29.9 N, p = 0.92; and 12 weeks: 98.9 ± 33.5 N/102.2 ± 38.3 N, p = 0.80). Pull-out failure from the femoral tunnel was only observed in two rabbits in the US group and one rabbit in the DR group at 4 weeks postoperatively. At 8 and 12 weeks, all specimens had a mid-substance tear. The collagen fiber continuity between tendon and bone occurred 8 weeks postoperatively in both groups and no histological difference was recognized throughout the evaluation period. CONCLUSIONS The tunnels created using the new US device and the conventional drill had equivalent biomechanical and histological features in tendon-bone healing. The bone excavation technology by the new US device may be applicable in ligament reconstructive surgeries.
Collapse
|
14
|
Parallel plate fixation for distal humeral fracture: Computer simulation to determine the appropriate screw insertion sequence. J Orthop Sci 2021; 26:860-864. [PMID: 33309403 DOI: 10.1016/j.jos.2020.07.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 07/02/2020] [Accepted: 07/24/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Parallel plate fixation for distal humeral fractures provides good clinical outcomes. However, few studies have investigated the insertion sequence of the distal screws, although long screw insertion into the distal fragment is technically demanding. The purpose of this study was to investigate a correlation between the insertion sequence of the distal screws and the screw insertion difficulty. METHODS Medial and lateral anatomical locking plates were closely fitted to the medial and lateral sides of the 10 intact humerus bone models on the computer. Most distal screws have 2 patterns: the screw was inserted from the lateral side first followed by insertion from the medial side (group 1) or from the medial side first followed by insertion from the lateral side (group 2). We calculated the target area wherein the second screw can be inserted. RESULTS The length of the first most distal screw in group 2 was significantly longer than that in group 1 (58.4 vs. 49.8 mm, p < 0.05). The target areas in both groups were divided into the distal and proximal areas. The distal and proximal areas in group 1 were 91.6 and 61.6 mm2, respectively, and those in group 2 were 191.1 and 11.3 mm2, respectively. The distal area in group 2 was significantly greater than in the other areas (p < 0.05). CONCLUSIONS In parallel plate fixation for distal humeral fracture, most distal screws could be more easily inserted from the medial side first followed by insertion from the lateral side than from the lateral side first followed by insertion from the medial side.
Collapse
|
15
|
2D-3D reconstruction of distal forearm bone from actual X-ray images of the wrist using convolutional neural networks. Sci Rep 2021; 11:15249. [PMID: 34315946 PMCID: PMC8316567 DOI: 10.1038/s41598-021-94634-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 05/06/2021] [Indexed: 01/08/2023] Open
Abstract
The purpose of the study was to develop a deep learning network for estimating and constructing highly accurate 3D bone models directly from actual X-ray images and to verify its accuracy. The data used were 173 computed tomography (CT) images and 105 actual X-ray images of a healthy wrist joint. To compensate for the small size of the dataset, digitally reconstructed radiography (DRR) images generated from CT were used as training data instead of actual X-ray images. The DRR-like images were generated from actual X-ray images in the test and adapted to the network, and high-accuracy estimation of a 3D bone model from a small data set was possible. The 3D shape of the radius and ulna were estimated from actual X-ray images with accuracies of 1.05 ± 0.36 and 1.45 ± 0.41 mm, respectively.
Collapse
|
16
|
Bone resorption of the greater tuberosity after open reduction and internal fixation of complex proximal humeral fractures: fragment characteristics and intraoperative risk factors. J Shoulder Elbow Surg 2021; 30:1626-1635. [PMID: 33038499 DOI: 10.1016/j.jse.2020.09.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 09/01/2020] [Accepted: 09/21/2020] [Indexed: 02/01/2023]
Abstract
HYPOTHESIS AND BACKGROUND In complex proximal humeral fractures, bone resorption of the greater tuberosity is sometimes observed after open reduction and internal fixation (ORIF). However, this has not been well characterized, and risk factors for resorption are not completely understood. We aimed (1) to identify the risk factors associated with bone resorption of the greater tuberosity and (2) to quantify the geometric and bone density characteristics associated with bone resorption using 3-dimensional computed tomography models in complex proximal humeral fractures treated with ORIF. METHODS We identified a retrospective cohort of 136 patients who underwent ORIF of 3- or 4-part proximal humeral fractures; greater tuberosity resorption developed after ORIF in 30 of these patients. We collected demographic, fracture-related, and surgery-related characteristics and performed multivariable logistic regression analysis to identify factors independently associated with the development of greater tuberosity resorption. Furthermore, we identified 30 age- and sex-matched patients by use of propensity score matching to perform quantitative fragment-specific analysis using 3-dimensional computed tomography models. After the fragment of the greater tuberosity was identified, the number of fragments, the relative fragment volume to the humeral head, and the relative bone density to the coracoid process were calculated. Measurements were compared between matched case-control groups. RESULTS We found that an unreduced greater tuberosity (odds ratio [OR], 10.9; P < .001), inadequate medial support at the calcar (OR, 15.0; P < .001), and the use of an intramedullary fibular strut (OR, 4.5; P = .018) were independently associated with a higher risk of bone resorption. Quantitative fragment-specific analysis showed that greater tuberosities with a larger number of fragments (5 ± 2 vs. 3 ± 2, P = .021), smaller fragments (9.9% ± 3.8% vs. 18.6% ± 4.7%, P < .001), and fragments with a lower bone density (66.4% ± 14.3% vs. 88.0% ± 18.4%, P = .001) had higher rates of resorption. DISCUSSION AND CONCLUSION An unreduced greater tuberosity or inadequate medial support increases the risk of greater tuberosity resorption, as do a larger number of fracture fragments, smaller fragments, and lower bone density. Additionally, fibular strut grafting is an independent risk factor for tuberosity resorption. Further study is needed, but alternatives to strut grafting such as femoral head allograft may warrant serious consideration.
Collapse
|
17
|
Utility of a 3-dimensionally printed color-coded bone model to visualize impinging osteophytes for arthroscopic débridement arthroplasty in elbow osteoarthritis. J Shoulder Elbow Surg 2021; 30:1152-1158. [PMID: 33486060 DOI: 10.1016/j.jse.2020.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 11/28/2020] [Accepted: 12/05/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The identification and precise removal of bony impingement lesions during arthroscopic débridement arthroplasty for elbow osteoarthritis require a high level of experience and surgical skill. We have developed a new technique to identify impinging osteophytes on a computer display by simulating elbow motion using the multiple positions of 3-dimensional (3D) elbow models created from computed tomography data. Moreover, an actual color-coded 3D model indicating the impinging osteophytes was created with a 3D printer and was used as an intraoperative reference tool. This study aimed to verify the efficacy of these new technologies in arthroscopic débridement for elbow osteoarthritis. METHODS We retrospectively studied 16 patients treated with arthroscopic débridement for elbow osteoarthritis after a preoperative computer simulation. Patients who underwent surgery with only the preoperative simulation were assigned to group 1 (n = 8), whereas those on whom we operated using a color-coded 3D bone model created from the preoperative simulation were assigned to group 2 (n = 8). Elbow extension and flexion range of motion (ROM), the Mayo Elbow Performance Score (MEPS), and the severity of osteoarthritis were compared between the groups. RESULTS Although preoperative elbow flexion and MEPS values were not significantly different between the groups, preoperative extension was significantly more restricted in group 2 than in group 1 (P = .0131). Group 2 tended to include more severe cases according to the Hastings-Rettig classification (P = .0693). ROM and MEPS values were improved in all cases. No significant differences in postoperative ROM or MEPS values were observed between the groups. There were no significant differences in the improvement in ROM or MEPS values between the 2 groups. CONCLUSIONS The use of preoperative simulation and a color-coded bone model could help to achieve as good postoperative ROM and MEPS values for advanced elbow osteoarthritis as those for early and intermediate stages.
Collapse
|
18
|
Computer-Aided Assessment of Displacement and Reduction of Distal Radius Fractures. Diagnostics (Basel) 2021; 11:diagnostics11040719. [PMID: 33919594 PMCID: PMC8073711 DOI: 10.3390/diagnostics11040719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 04/15/2021] [Accepted: 04/15/2021] [Indexed: 11/16/2022] Open
Abstract
This study aims to investigate displacements and reductions of distal radius fractures using measurement indices based on the computer-aided three-dimensional (3D) radius shape model. Fifty-two distal radius fracture patients who underwent osteosynthesis were evaluated with pre- and post-operative distal radius 3D images. In the 3D images, three reference points, i.e., the radial styloid process (1), sigmoid notch volar, and dorsal edge (2) (3) were marked. The three-dimensional coordinates of each reference point and the barycentric coordinates of the plane connecting the three reference points were evaluated. The distance and direction moved, due to the reductions for each reference point, were (1) 12.1 ± 8.1 mm in the ulnar-palmar-distal direction, (2) 7.5 ± 4.1 mm in the ulnar-palmar-proximal direction, and (3) 8.2 ± 4.7 mm in the ulnar-palmar-distal direction relative to the preoperative position. The barycentric coordinate moved 8.4 ± 5.3 mm in the ulnar-palmar-distal direction compared to the preoperative position. This analyzing method will be helpful to understand the three-dimensional direction and the extent of displacements in distal radius fractures.
Collapse
|
19
|
Divertor heat load distribution measurements with infrared thermography in the LHD helical divertor. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
20
|
A Three-Step Method for the Treatment of Radioulnar Synostosis with Posterior Radial Head Dislocation. J Hand Surg Asian Pac Vol 2021; 26:118-125. [PMID: 33559562 DOI: 10.1142/s2424835521710016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Congenital radioulnar synostosis with posterior dislocation of the radial head remains challenging to treat. We describe a three-step treatment method that combines radial shaft osteotomy with a custom-made device, ulnar shaft osteotomy, and local adipofascial flap elevation procedures. For posterior radial head dislocation treatment, osteotomy near the proximal radius cannot recover physiological rotation of the radial head. Thus, we chose a precise radial shaft osteotomy with a custom-made device according to preoperative planning based on three-dimensional evaluation of the bone deformation. Performing radial shaft osteotomy alone, however, may not be enough to achieve sufficient supination range of motion. We, therefore, also performed ulnar shaft osteotomy. Finally, we elevated the local adipofascial flap to prevent re-adhesion. In three patients, the range of motion of the elbow improved postoperatively. In conclusion, our three-step method does not require a microsurgical technique and is easy to perform.
Collapse
|
21
|
In vivo three-dimensional scapular kinematic alterations after reverse total shoulder arthroplasty. J Orthop Surg (Hong Kong) 2021; 28:2309499020921979. [PMID: 32390500 DOI: 10.1177/2309499020921979] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND In vivo three-dimensional (3D) kinematics of the scapula after reverse total shoulder arthroplasty (rTSA) have been sparsely investigated. The aim of this study was to analyze static and dynamic kinematic alterations of the scapula after rTSA in vivo with the use of computer-aided 3D reconstruction program. METHODS A total of 15 patients with cuff tear arthropathy treated by rTSA participated. Scapulae with rTSA and the contralateral scapulae were evaluated with computed tomography scan data in 0° and 120° forward flexion positions of the glenohumeral joint. To examine static scapular kinematic alterations, the angular position and distance from the thorax were evaluated in the shoulder neutral position. 3D rotational and translational movements of the scapula in relation to the thorax were also measured during arm elevation to evaluate dynamic scapular kinematic alterations. RESULTS Scapulae with rTSA were more anteriorly tilted in the sagittal plane and more internally rotated in the axial plane than were the contralateral scapulae. However, no significant differences were observed in the upward rotated position in the coronal plane or in the distance from the thorax in any plane between the scapulae with rTSA and the contralateral scapulae. In dynamic analyses, upward rotational movement in the coronal plane, external rotation in the axial plane, and posterior tilting in the sagittal plane showed significant differences between the scapulae with rTSA and the contralateral scapulae during elevation. In contrast, translational movements in coordination revealed no statistical differences between the two scapular groups except for lateral translation. CONCLUSION Data from the 3D reconstruction program showed that rTSA might result in static positional changes and dynamic movement alterations. LEVEL OF EVIDENCE Therapeutic, IV.
Collapse
|
22
|
Three-dimensional evaluations of preoperative planning reproducibility for the osteosynthesis of distal radius fractures. J Orthop Surg Res 2021; 16:131. [PMID: 33579338 PMCID: PMC7879530 DOI: 10.1186/s13018-021-02278-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 02/03/2021] [Indexed: 03/18/2023] Open
Abstract
BACKGROUND Three-dimensional preoperative planning was applied for the osteosynthesis of distal radius fractures. The objective of this study was to evaluate the reproducibility of three-dimensional preoperative planning for the osteosynthesis of distal radius fractures with three-dimensional reference points. METHODS Sixty-three wrists of 63 distal radius fracture patients who underwent osteosynthesis with three-dimensional preoperative planning were evaluated. After taking preoperative CT scans of the injured wrists, 3D images of the distal radius were created. Fracture reduction, implants choices, and placements simulation were performed based on the 3D images. One month after the surgery, postoperative CT images were taken. The reproducibility was evaluated with preoperative plan and postoperative 3D images. The images were compared with the three-dimensional coordinates of radial styloid process, volar and dorsal edges of sigmoid notch, and the barycentric coordinates of the three reference points. The reproducibility of the preoperative plan was evaluated by the distance of the coordinates between the plan and postoperative images for the reference points. The reproducibility of radial inclination and volar tilt on three-dimensional images were evaluated by intra-class correlation coefficient (ICC). RESULTS The distances between the preoperative plan and the postoperative reduction for each reference point were (1) 2.1±1.3 mm, (2) 1.9±1.2 mm, and (3) 1.9±1.2 mm, respectively. The distance between the preoperative plan and postoperative reduction for the barycentric coordinate was 1.3±0.8 mm. ICCs were 0.54 and 0.54 for the volar tilt and radial inclination, respectively (P<0.01). CONCLUSIONS Three-dimensional preoperative planning for the osteosynthesis of distal radius fracture was reproducible with an error of about 2 mm for each reference point and the correlations of reduction shapes were moderate. The analysis method and reference points may be helpful to understand the accuracy of reductions for the three-dimensional preoperative planning in the osteosynthesis of distal radius fractures. TRIAL REGISTRATION Registered as NCT02909647 at ClinicalTrials.gov.
Collapse
|
23
|
Abstract
Aims We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s correlation coefficient (R) = 0.85 to 0.95). Using 2D measurements, ROC curve analysis revealed the optimal cutoffs of 90.8% and 116.3% for distal and proximal fragments. This led to a sensitivity of 1.00 if either cutoff is met and a specificity of 0.82 when both cutoffs are met. Conclusion Using 3D modelling software, nonunions were found to exhibit bone density increases in both the distal and proximal fragments in CTs performed between four to 18 weeks after fracture during the course of treatment. 2D bone density measurements using standard CT scans correlate well with 3D models. In patients with scaphoid fractures, CT bone density measurements may be useful in predicting the likelihood of nonunion. Cite this article: Bone Joint J 2020;102-B(9):1200–1209.
Collapse
|
24
|
Three-dimensional analysis of displacement characteristics of dorsally angulated intra-articular distal radial fractures. J Hand Surg Eur Vol 2020; 45:339-347. [PMID: 31722638 DOI: 10.1177/1753193419885265] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Understanding the complex fragmentation of intra-articular distal radial fractures contributes to achieving anatomical reduction during surgery. This study aimed to clarify three-dimensional displacement patterns of intra-articular fragmentation in dorsally angulated, intra-articular distal radial fractures. We identified five characteristic intra-articular fragments: a key fragment, dorsal ulnar corner, dorsal wall, radial column and anterior radial column. The key fragment was displaced with radial deviation, pronation and extension and with dorsal, proximal and radial translations. The dorsal ulnar corner displacement resulted in a gap, a step-off and a deepened concavity for the lunate facet and sigmoid notch. The dorsal wall displacement resulted in a deepened concavity, a gap and a step-off of the dorsal scaphoid facet. The displacements of the radial column and anterior radial column caused a step-off between the scaphoid and lunate facets. The five characteristic intra-articular fragments each created a characteristic gap and step-off in the articular surface. Level of evidence: IV.
Collapse
|
25
|
Combination of Electrospun Nanofiber Sheet Incorporating Methylcobalamin and PGA-Collagen Tube for Treatment of a Sciatic Nerve Defect in a Rat Model. J Bone Joint Surg Am 2020; 102:245-253. [PMID: 31609892 DOI: 10.2106/jbjs.19.00254] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND For peripheral nerve defects, autografting is considered the therapeutic gold-standard treatment. However, this procedure leads to donor-site morbidity. While various artificial conduits have been recently developed, treatment outcome has been demonstrated to be poorer than that with autograft. In our previous study using a rat sciatic nerve crush injury model, we demonstrated that the delivery of electrospun nanofiber sheets incorporating methylcobalamin (MeCbl sheet) to the local site of a peripheral nerve injury promoted peripheral nerve regeneration. In this study, we examined the effects of combination therapy using an MeCbl sheet and a polyglycolic acid tube filled with collagen sponge (PGA-c) in a rat model of a 10-mm sciatic nerve defect. METHODS The rats were divided into 4 groups: (1) sham group (n = 10); (2) PGA-c group (n = 9), in which the gap was bridged using a PGA-c; (3) PGA-c/Sheet group (n = 8), in which the gap was bridged using a PGA-c wrapped in an MeCbl sheet; and (4) autograft group (n = 10), in which the gap was bridged using a reversed autograft. Motor and sensory function were evaluated, electrophysiological analysis was performed, and histomorphological findings were analyzed at 12 weeks postoperatively. RESULTS Compared with the PGA-c group, the PGA-c/Sheet group demonstrated significant improvements in the paw-withdrawal threshold expressed as a ratio relative to the contralateral side (mean difference [MD], -1.51; 95% confidence interval [CI], -2.64 to -0.38), terminal latency (MD, -0.86 ms; 95% CI, -1.56 to -0.16 ms), myelinated axon area (MD, 4.97%; 95% CI, 0.14% to 9.80%), proportion of myelinated axons (MD, 8.453%; 95% CI, 0.001% to 16.905%), and g-ratio (MD, -0.018; 95% CI, -0.035 to -0.001). No significant improvements were observed regarding motor function, electrophysiological findings with the exception of terminal latency, and axon numbers. CONCLUSIONS An MeCbl sheet in combination with a PGA-c significantly accelerated recovery with respect to sensory function, electrophysiology, and histomorphometry. CLINICAL RELEVANCE An MeCbl sheet may represent an effective therapeutic strategy for promoting regeneration across a nerve gap bridged with an artificial conduit.
Collapse
|
26
|
Utility of Distal Forearm DXA as a Screening Tool for Primary Osteoporotic Fragility Fractures of the Distal Radius: A Case-Control Study. JB JS Open Access 2020; 5:e0036. [PMID: 32309758 PMCID: PMC7147634 DOI: 10.2106/jbjs.oa.19.00036] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Osteoporotic fragility fractures frequently occur at the distal part of the radius. This suggests that initial osteoporosis evaluation at this site may inform screening and treatment to prevent additional fractures. The purpose of this study was to investigate the utility of distal forearm dual x-ray absorptiometry (DXA) as a screening tool to assess the risk of fragility fractures at the distal part of the radius. METHODS This retrospective, case-control study included postmenopausal women who had sustained a distal radial fracture (fracture group, n = 110) and postmenopausal women with no history of fracture (control group, n = 95). DXA measurements at the spine, hip, and distal part of the forearm (ultra-distal, mid-distal, and one-third distal sections) were compared between the groups on the basis of bone mineral density (BMD), T-score, and the proportion of patients with a T-score of ≤-2.5 standard deviations (SD). We also investigated the regional differences on the basis of T-score among the skeletal sites. Furthermore, the reliability of distal forearm DXA measurements was validated by assessing the statistical correlation (r) with volumetric BMD by computed tomography (CT). RESULTS Compared with the control group, the fracture group showed significantly lower BMD and T-scores and higher proportions of patients with a T-score of ≤-2.5 SD at the ultra-distal, mid-distal, and one-third distal forearm; however, the spine and hip measurements did not differ significantly between the 2 groups. With respect to regional differences, in the fracture group, T-scores were significantly lower and the proportions of patients with a T-score of ≤-2.5 SD were significantly higher for the 3 distal forearm sites compared with the spine and hip. DXA measurements at all 3 of the distal forearm regions exhibited high correlation with volumetric BMD by CT (r = 0.83 to 0.92). CONCLUSIONS Some postmenopausal women were found to exhibit bone loss preferentially at the distal part of the radius, which may render them vulnerable to fragility fractures. Forearm DXA for the assessment of local bone loss may demonstrate benefit in screening for those at risk for distal radial fractures and facilitate the early identification of patients who require intervention for osteoporosis. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
27
|
Virulence of Escherichia coli Isolates Obtained from Layer Chickens with Colibacillosis Associated with Pericarditis, Perihepatitis, and Salpingitis in Experimentally Infected Chicks and Embryonated Eggs. Avian Dis 2019; 62:233-236. [PMID: 29944397 DOI: 10.1637/11685-060717-resnote.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
To evaluate the virulence of avian pathogenic Escherichia coli (APEC) isolates obtained from colibacillosis cases associated with pericarditis, perihepatitis, and salpingitis, the embryo lethality assay and experimental infection model in chicks were used in this study. According to the established criteria based on mortality in the embryo lethality assay for evaluating the virulence of E. coli isolates, 23 of the 26 APEC isolates associated with pericarditis and perihepatitis and 8 of the 20 isolates associated with salpingitis were found to be virulent. Isolate D137, which had been obtained from a case with pericarditis and perihepatitis and had an embryo mortality of 92%, and isolate D445, which had been obtained from a case with pericarditis and perihepatitis and had an embryo mortality of 17%, were used for the experimental infection. Four of the five 11-day-old chickens inoculated through the air sac with isolate D137 died 1 day postinoculation, and the challenge strain was recovered from the air sac, pericardial sac, or liver; however, colibacillosis lesions were found in only one of the five birds postmortem. All five chicks inoculated with isolate D445 survived for 7 days postinoculation and exhibited airsacculitis or pericarditis lesions at 7 days postinoculation; the challenge strain was not recovered from the lesions postmortem. The results obtained in this study suggest that the different APEC isolates tested cause illness in chickens through distinct pathogenesis.
Collapse
|
28
|
Single-plane rotational osteotomy for cubitus varus deformity based on preoperative computer simulation. J Orthop Sci 2019; 24:945-951. [PMID: 28539249 DOI: 10.1016/j.jos.2017.04.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 12/07/2016] [Accepted: 05/01/2017] [Indexed: 10/19/2022]
|
29
|
Three-Dimensional In Vivo Analysis of Malunited Distal Radius Fractures With Restricted Forearm Rotation. J Orthop Res 2019; 37:1881-1891. [PMID: 31038231 DOI: 10.1002/jor.24332] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Accepted: 04/16/2019] [Indexed: 02/04/2023]
Abstract
Malunited distal radius fractures (DRFs) occasionally restrict forearm rotation, but the underlying pathology remains unclear. We aimed to elucidate the mechanism of rotational restriction by retrospective analysis of 23 patients with unilateral malunited DRFs who presented restricted forearm rotation. We conducted computed tomography during forearm rotation on both sides. Three-dimensional (3D) bone surface models of the forearm were created, and 3D deformity of the distal radius, translation of the distal radius relative to the ulna, distal radioulnar joint (DRUJ) contact area, and estimated path length (EPL) of distal radioulnar ligaments (DRUL) during forearm rotation were evaluated. In total, 18 patients had dorsal angular deformities (DA group) and five had volar angular deformities (VA group). In the DA group, the closest point between the distal radius and ulna on DRUJ was displaced to the volar side during supination and pronation (p < 0.001); DRUJ contact area was not significantly different between the DA and normal groups. In bone-ligament model simulation, the EPL of dorsal DRUL was longer in the DA group than in the normal group (p < 0.001); opposite phenomena were observed in the VA group. In the DA group, translation of the distal radius in a volar direction relative to the ulna during pronation was impaired presumably due to dorsal DRUL tightness. Anatomical normal reduction of the distal radius by corrective osteotomy may improve forearm rotation by improving triangular fibrocartilage complex tightness and normalizing translation of the distal radius relative to the ulna. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1881-1891, 2019.
Collapse
|
30
|
The morphologic change of the elbow with flexion contracture in upper obstetric brachial plexus palsy. J Shoulder Elbow Surg 2019; 28:1764-1770. [PMID: 31043347 DOI: 10.1016/j.jse.2019.02.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 02/04/2019] [Accepted: 02/15/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Contracture of the elbow after obstetric brachial plexus palsy (OBPP) is well known; however, details of the 3-dimensional (3D) morphologic changes in the elbow joint in OBPP have not been clarified. This study aimed to clarify the 3D morphologic changes in the elbow joint by focusing on the distal humerus with flexion contracture in upper OBPP. We tested the hypothesis that the shape of the distal humerus with flexion contracture in upper OBPP is hypoplastic in the trochlea, capitellum, and olecranon fossa. METHODS We retrospectively studied 20 patients with elbow flexion contracture and residual OBPP. The approximate radius of the distal humerus, the shortest distance between the olecranon and coronoid fossa, and the size of the olecranon fossa were measured and compared between the affected and normal sides using 3D bone models to assess the distal humerus morphology. RESULTS The average radius of the distal humerus was smaller on the affected side than on the normal side. Furthermore, the average distance between the olecranon and coronoid fossa was greater and the average size of the olecranon fossa was smaller on the affected side than on the normal side. The size of the distal humerus was significantly smaller and the olecranon fossa was significantly shallower on the affected side. CONCLUSIONS Consistent with our original hypothesis, the distal humerus with flexion contracture in upper OBPP was hypoplastic. The shallow olecranon fossa might prevent full extension of the elbow even though soft tissue contracture release is performed. We recommend evaluation of the morphology of the olecranon fossa to determine the treatment plan for elbow flexion contracture with OBPP.
Collapse
|
31
|
Cartilage wear patterns in severe osteoarthritis of the trapeziometacarpal joint: a quantitative analysis. Osteoarthritis Cartilage 2019; 27:1152-1162. [PMID: 30954554 DOI: 10.1016/j.joca.2019.03.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 03/12/2019] [Accepted: 03/27/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The present quantitative study aimed to assess the three-dimensional (3-D) cartilage wear patterns of the first metacarpal and trapezium in the advanced stage of osteoarthritis (OA) and compare cartilage measurements with radiographic severity. DESIGN Using 19 cadaveric trapeziometacarpal (TMC) joints, 3-D cartilage surface models of the first metacarpal and trapezium were created with a laser scanner, and 3-D bone surface model counterparts were similarly created after dissolving the cartilage. These two models were superimposed, and the interval distance on the articular surface as the cartilage thickness was measured. All measurements were obtained in categorized anatomic regions on the articular surface of the respective bone, and we analyzed the 3-D wear patterns on the entire cartilage surface. Furthermore, we compared measurements of cartilage thickness with radiographic OA severity according to the Eaton grading system using Pearson correlation coefficients (r). RESULTS In the first metacarpal, the cartilage thickness declined volarly (the mean cartilage thickness of the volar region was 0.32 ± 0.16 mm, whereas that of the dorsal region was 0.53 ± 0.18 mm). Conversely, the cartilage evenly degenerated throughout the articular surface of the trapezium. Measurements of the categorized regions where cartilage thinning was remarkable exhibited statistical correlations with radiographic staging (r = -0.48 to -0.72). CONCLUSIONS Our findings indicate that cartilage wear patterns differ between the first metacarpal and trapezium in the late stage of OA. There is a need for further studies on cartilage degeneration leading to symptomatic OA in the TMC joint.
Collapse
|
32
|
Regional Distribution of Articular Cartilage Thickness in the Elbow Joint: A 3-Dimensional Study in Elderly Humans. JB JS Open Access 2019; 4:JBJSOA-D-19-00011. [PMID: 31592501 PMCID: PMC6766381 DOI: 10.2106/jbjs.oa.19.00011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
During elbow procedures, reconstruction of the joint (including the articular cartilage) is important in order to restore elbow function; however, the regional distribution of elbow cartilage is not completely understood. The purpose of the present study was to investigate the 3-dimensional (3-D) distribution patterns of cartilage thickness of elbow bones (including the distal part of the humerus, proximal part of the ulna, and radial head) in order to elucidate the morphological relationship among them.
Collapse
|
33
|
Open Wedge Osteotomy with Ulnar Shortening for Madelung Deformity Using a Computer-Generated Template. J Hand Surg Asian Pac Vol 2019; 22:538-543. [PMID: 29117834 DOI: 10.1142/s021881041772042x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A variety of osteotomies have been reported to correct Madelung deformity using plain radiographs. However, evaluation of the deformity using 2-dimensional plain radiography is difficult because of its complex 3-dimensional nature. Therefore, we performed corrective osteotomy using recently developed 3D simulation technology on an adult woman with Madelung deformity, and achieved an excellent outcome. In this study, we calculated the amount of parallel displacement as well as the rotational angle for more precise correction, and performed open wedge osteotomy. Furthermore, we performed concurrent ulnar shortening. An exaggerated radial inclination was observed in the posteroanterior radiograph. A palmar shift of the carpus and dorsal dislocation of the ulnar head were observed in the lateral radiograph. In the preoperative findings, radial inclination (RI), volar tilt (VT), and ulnar variance (UV) were 35°, 40°, and 12 mm, respectively. The wrist showed improvement, with an RI of 25°, VT of 14°, and UV of 0 mm. At present, 14 months after surgery, there has been no loss of correction, instability of the ulnar head, or pain on the ulnar side. The procedure resulted in improvements in the protrusion and pain in the ulnar portion of the patient's wrist. Based on this result, we believe that accurate corrective osteotomy with ulnar shortening should be performed for Madelung deformity.
Collapse
|
34
|
SUN-159 RENAL PROTECTIVE EFFECT OF LACTULOSE TARGETING OF GUT-KIDNEY AXIS. Kidney Int Rep 2019. [DOI: 10.1016/j.ekir.2019.05.560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
35
|
New installation of in-vessel Non Evaporable Getter (NEG) pumps for the divertor pump in the LHD. FUSION ENGINEERING AND DESIGN 2019. [DOI: 10.1016/j.fusengdes.2019.03.164] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
36
|
Effects of Weekly Teriparatide Administration for Vertebral Stability and Bony Union in Patients with Acute Osteoporotic Vertebral Fractures. Asian Spine J 2019; 13:763-771. [PMID: 31000686 PMCID: PMC6774000 DOI: 10.31616/asj.2018.0311] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 02/07/2019] [Indexed: 12/12/2022] Open
Abstract
Study Design An open-label, non-randomized prospective study. Purpose Teriparatide (TPTD) is known to be an antiosteoporotic agent that may accelerate the healing of fractures. This study was designed to investigate the effect of once-weekly TPTD administration on vertebral stability and bony union after acute osteoporotic vertebral fracture (OVF). Overview of Literature Once-weekly TPTD administration can lead to early vertebral stability and promote bony union of fractured vertebrae in patients with severe osteoporosis. Methods Forty-eight subjects with acute OVF were assigned to receive activated vitamin D3 and calcium supplementation or onceweekly subcutaneous injection of TPTD (56.5 μg) in combination with activated vitamin D3 and calcium supplementation for 12 weeks. Vertebral stability was assessed using lateral plain radiography. Vertebral height at the anterior location (VHa) and the difference in VHa {ΔVHa=VHa (supine position)−VHa (weight-bearing position)} were measured at baseline and 12 weeks after starting treatment. Bony union was defined as the absence of a vertebral cleft or abnormal motion (ΔVHa >2 mm). Results Although not significant, ΔVHa, indicating vertebral stability, tended to be lower in the TPTD group at 12 weeks (p =0.17). As for subjects with severe osteoporosis, ΔVHa at 12 weeks was significantly lower in the TPTD group than in the control group (mean ΔVHa: control group, 3.1 mm (n=15); TPTD group, 1.4 mm (n=16); p =0.02). The rate of bony union was significantly higher in the TPTD group than in the control group (control group, 40%; TPTD group, 81%; p =0.03). Conclusions Once-weekly TPTD administration may facilitate early bony union after acute OVF accompanied by severe osteoporosis.
Collapse
|
37
|
Analysis of forearm rotational motion using biplane fluoroscopic intensity-based 2D-3D matching. J Biomech 2019; 89:128-133. [PMID: 31060811 DOI: 10.1016/j.jbiomech.2019.04.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 04/11/2019] [Accepted: 04/11/2019] [Indexed: 12/28/2022]
Abstract
Measuring three-dimensional (3D) forearm rotational motion is difficult. We aimed to develop and validate a new method for analyzing 3D forearm rotational motion. We proposed biplane fluoroscopic intensity-based 2D-3D matching, which employs automatic registration processing using the evolutionary optimization strategy. Biplane fluoroscopy was conducted for forearm rotation at 12.5 frames per second along with computed tomography (CT) at one static position. An arm phantom was embedded with eight stainless steel spheres (diameter, 1.5 mm), and forearm rotational motion measurements using the proposed method were compared with those using radiostereometric analysis, which is considered the ground truth. As for the time resolution analysis, we measured radiohumeral joint motion in a patient with posterolateral rotatory instability and compared the 2D-3D matching method with the simulated multiple CT method, which uses CTs at multiple positions and interpolates between the positions. Rotation errors of the radius and ulna between these two methods were 0.31 ± 0.35° and 0.32 ± 0.33°, respectively, translation errors were 0.43 ± 0.35 mm and 0.29 ± 0.25 mm, respectively. Although the 2D-3D method could detect joint dislocation, the multiple CT method could not detect quick motion during joint dislocation. The proposed method enabled high temporal- and spatial-resolution motion analyses with low radiation exposure. Moreover, it enabled the detection of a sudden motion, such as joint dislocation, and may contribute to 3D motion analysis, including joint dislocation, which currently cannot be analyzed using conventional methods.
Collapse
|
38
|
Three-Dimensional Corrective Osteotomy for Malunited Fractures of the Upper Extremity Using Patient-Matched Instruments: A Prospective, Multicenter, Open-Label, Single-Arm Trial. J Bone Joint Surg Am 2019; 101:710-721. [PMID: 30994589 DOI: 10.2106/jbjs.18.00765] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Medical image processing has facilitated simulation of 3-dimensional (3-D) corrective osteotomy, and 3-D rapid prototyping technology has further enabled the manufacturing of patient-matched surgical guides and implants (patient-matched instruments, or PMIs). However, 3-D corrective osteotomy using these technologies has not been the standard procedure. We aimed to prospectively verify the efficacy and safety of PMIs in corrective osteotomy for deformities of the upper extremity. METHODS We enrolled 16 patients with a total of 17 bone deformities in the upper extremity. Eight patients had distal radial malunion; 5, distal humeral malunion; and 3, forearm diaphyseal malunion. All cases underwent 3-D corrective osteotomy with PMIs. The primary end point was the residual maximum deformity angle (MDA), which was calculated from 2 deformity angles-1 on the anteroposterior and 1 on the lateral postoperative radiograph. Secondary end points included the deformity angle on radiographs, 3-D error between the preoperative planning model and the postoperative result, range of motion, grip strength, pain measured with a visual analog scale (VAS), patient satisfaction, and Disabilities of the Arm, Shoulder and Hand (DASH) score. RESULTS The average MDA significantly improved from 25.5° preoperatively to 3.3° at the final follow-up (p < 0.001). The angular deformity was within 5° in all cases, except for 1 with distal radial malunion who had a higher angle on the anteroposterior radiograph. The error between the correction seen on the postoperative 3-D bone model and the planned correction was <1° and <1 mm. Flexion and extension of the wrist and pronation of the forearm of the patients treated for distal radial malunion improved significantly, and pronation improved for those treated for forearm diaphyseal malunion. The average VAS score, grip strength, and DASH score significantly improved as well. Of the 16 patients, 15 were very satisfied or satisfied with the outcomes. CONCLUSIONS Corrective osteotomy using PMIs achieved accurate correction and good functional recovery in the upper extremity. Although our study was limited to cases without any deformity on the contralateral side, 3-D corrective osteotomy using PMIs resolved treatment challenges for complex deformities in upper extremities. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
39
|
Demonstration of suppression of dust generation and partial reduction of the hydrogen retention by tungsten coated graphite divertor tiles in LHD. NUCLEAR MATERIALS AND ENERGY 2019. [DOI: 10.1016/j.nme.2018.11.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
40
|
Rotational and Varus Instability in Chronic Lateral Ankle Instability: In Vivo 3D Biomechanical Analysis. ACTA MEDICA OKAYAMA 2018; 72:583-589. [PMID: 30573913 DOI: 10.18926/amo/56376] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We retrospectively evaluated the altered biomechanics of the talus in 15 adult patients (7 males, 8 females) with chronic lateral ankle instability when the ankle joint moved actively from full dorsiflexion to full plantarflexion under a non-weight bearing condition. CT images were taken for the unstable ankle and the contralateral normal (control) ankle. Three-dimensional surface models of both ankle joints were reconstructed from the CT data, and we used a computer simulation program to compare both ankle motions of inversion/eversion in the coronal plane, plantarflexion/dorsiflexion in the sagittal plane, and internal rotation/external rotation in the axial plane. This evaluation method provides in vivo, dynamic, and 3D results of ankle motion. In the ankles with chronic lateral instability and the controls, the average talar rotational movement of inversion (+)/eversion (-) was 19.0° and 15.5° and the internal rotation (+)/external rotation (-) was 30.4° and 20.7°, respectively. Paired t-tests revealed significant differences in the amount of inversion (+)/eversion (-) (p=0.012) and internal rotation (+)/external rotation (-) (p<0.001) between unstable and normal ankle joints. The difference of mean rotational movement in internal rotation (9.7°) was greater than that of inversion (3.5°). Rotational instability should be considered when evaluating chronic lateral ankle instability.
Collapse
|
41
|
Surgical Technique of Corrective Osteotomy for Malunited Distal Radius Fracture Using the Computer-Simulated Patient Matched Instrument. J Hand Surg Asian Pac Vol 2018; 21:133-9. [PMID: 27454626 DOI: 10.1142/s2424835516400051] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The conventional corrective osteotomy for malunited distal radius fracture that employs dorsal approach and insertion of a trapezoidal bone graft does not always lead to precise correction or result in a satisfactory surgical outcome. Corrective osteotomy using a volar locking plate has recently become an alternative technique. In addition, the use of patient-matched instrument (PMI) via computed tomography simulation has been developed and is expected to simplify surgical procedures and improve surgical precision. The use of PMI makes it possible to accurately position screw holes prior to the osteotomy and simultaneously perform the correction and place the volar locking plate once the osteotomy is completed. The bone graft does not necessarily require a precise block form, and the problem of the extensor tendon contacting the dorsal plate is avoided. Although PMI placement and soft tissue release technique require some degree of specialized skill, they comprise a very useful surgical procedure. On the other hand, because patients with osteoporosis are at risk of peri-implant fracture, tandem ulnar shortening surgery should be considered to avoid excessive lengthening of the radius.
Collapse
|
42
|
In Vivo Three-Dimensional Analysis of Malunited Forearm Diaphyseal Fractures with Forearm Rotational Restriction. J Bone Joint Surg Am 2018; 100:e113. [PMID: 30180062 DOI: 10.2106/jbjs.17.00934] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The aim of this study was to clarify the mechanisms of rotational restriction in malunited forearm diaphyseal fractures. METHODS We retrospectively analyzed the cases of 18 patients with malunited forearm diaphyseal fractures and rotational restriction. All patients underwent bilateral computed tomography (CT) of the forearm in maximum supination, pronation, and neutral positions. From these images, we created 3-dimensional (3-D) bone surface models. We quantified the 3-D deformities, identified instances of osseous impingement between the radius and the ulna during forearm rotation, calculated the path length of the central band (CB) of the interosseous membrane, and measured forearm range of motion. RESULTS Sixteen patients had extension deformity of the radius (the RE group) and 2 had flexion deformity (the RF group). In the RE group, extension deformity of the radius and valgus deformity of the ulna had significant negative correlation with pronation range of motion (R = -0.50, p = 0.046) and supination range of motion (R = -0.63, p = 0.027), respectively. Osseous impingement was mainly observed during pronation (15 of 16 patients). The CB path with the largest changes in length originated from the distal CB attachment area of the radius and ran toward the proximal area of the ulna (the transverse CB). The transverse CB significantly increased in length in supination compared with that in pronation (p < 0.001). Therefore, tightness of the transverse CB appeared to cause supination restriction in the RE group. In the RF group, osseous impingement caused supination restriction. The greatest increases in the transverse CB length were observed in pronation in the RF group, which appeared to cause pronation restriction. CONCLUSIONS In the RE group, pronation restriction was associated with osseous impingement that was due to extension deformity of the radius, and supination restriction was associated with CB tightness that was due to valgus deformity of the ulna. In the RF group, our results suggested that pronation restriction was caused by CB tightness and that supination restriction was caused by osseous impingement. CLINICAL RELEVANCE Three-dimensional corrective osteotomy for extension deformity of the radius in malunited forearm diaphyseal fractures would improve rotational restriction by relieving osseous impingement during pronation and CB tightness during supination.
Collapse
|
43
|
Morphology and kinematics studies of the upper extremity and its clinical application in deformity correction. J Orthop Sci 2018; 23:722-733. [PMID: 30054134 DOI: 10.1016/j.jos.2018.05.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 03/10/2018] [Accepted: 05/21/2018] [Indexed: 10/28/2022]
Abstract
Morphological and kinetic studies using computer-generated bone models are helpful for determining normal articular movements and various pathological conditions of the wrist joints, forearms, and elbow joints. Previous studies consisted of kinetic analyses that were carried out by superimposing three-dimensional bone models created on a computer on the basis of CT data obtained by scanning the limbs in several different positions. We applied the techniques used in such studies and have discovered a method for carrying out surgical procedure simulations aimed at correcting upper limb deformities. In addition, we have developed a system aimed at assisting surgical procedures conducted in accordance with simulations by using patient-matched guides (patient-matched instruments, PMI) and custom-made osteosynthesis plates. Our system has allowed for accurate anatomical corrections to be carried out three-dimensionally during a simple surgical procedure. The system was clinically used in the treatment of cubitus varus as well as malunited distal radial fractures and forearm fractures. As a result, accurate correction and favorable clinical outcomes have been achieved. Together with the development of therapeutic techniques, we have also simultaneously developed the related technological system, which consists of imaging protocols aimed at reducing the amount of radiation exposure and creating statistical shape models, as well as web-based tools for communication between physicians and engineers.
Collapse
|
44
|
Three-dimensional analysis of deformities of the radius and ulna in congenital proximal radioulnar synostosis. J Hand Surg Eur Vol 2018; 43:739-743. [PMID: 29402171 DOI: 10.1177/1753193417753261] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We reconstructed three-dimensional images of radius and ulna in 38 forearms of 25 patients with congenital proximal radioulnar synostosis from their computed tomographic studies. We also analysed correlations between the deformities of radius and ulna and degrees of fixed pronation of these forearms. The average ulnar deviation, flexion and internal rotation deformities of the radius were 6°, 3° and 18°, respectively. The average radial deviation, extension and internal rotation deformities of the ulna were 3°, 4° and 30°, respectively. The flexion deformity of the radius and the internal rotation deformity of the radius and ulna were correlated significantly with degree of fixed pronation. We conclude that the patients with congenital proximal radioulnar synostosis have remarkable flexion deformity of the radius and internal rotation deformity of the radius and ulna, which might impede forearm rotation after corrective surgery in the proximal part of the forearm.
Collapse
|
45
|
In vivo 3-dimensional Kinematics of Cubitus Valgus after Non-united Lateral Humeral Condyle Fracture. Clin Shoulder Elb 2018; 21:151-157. [PMID: 33330169 PMCID: PMC7726386 DOI: 10.5397/cise.2018.21.3.151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 07/26/2018] [Accepted: 07/27/2018] [Indexed: 11/29/2022] Open
Abstract
Background Nonunion of lateral humeral condyle fracture causes cubitus valgus deformity. Although corrective osteotomy or osteosynthesis can be considered, there are controversies regarding its treatment. To evaluate elbow joint biomechanics in non-united lateral humeral condyle fractures, we analyzed the motion of elbow joint and pseudo-joint via in vivo three-dimensional (3D) kinematics, using 3D images obtained by computed tomography (CT) scan. Methods Eight non-united lateral humeral condyle fractures with cubitus valgus and 8 normal elbows were evaluated in this study. CT scan was performed at 3 different elbow positions (full flexion, 90° flexion and full extension). With bone surface model, 3D elbow motion was reconstructed. We calculated the axis of rotation in both the normal and non-united joints, as well as the rotational movement of the ulno-humeral joint and pseudo-joint of non-united lateral condyle in 3D space from full extension to full flexion. Results Ulno-humeral joint moved to the varus on the coronal plane during flexion, 25.45° in the non-united cubitus valgus group and -2.03° in normal group, with statistically significant difference. Moreover, it moved to rotate externally on the axial plane -26.75° in the non-united cubitus valgus group and -3.09° in the normal group, with statistical significance. Movement of the pseudo-joint of fragment of lateral condyle showed irregular pattern. Conclusions The non-united cubitus valgus group moved to the varus with external rotation during elbow flexion. The pseudo-joint showed a diverse and irregular motion. In vivo 3D motion analysis for the non-united cubitus valgus could be helpful to evaluate its kinematics.
Collapse
|
46
|
1349Increased plasma xanthine oxidoreductase activity is associated with coronary artery spasm. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.1349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
47
|
Corrective osteotomy for hyperextended elbow with limited flexion due to supracondylar fracture malunion. J Shoulder Elbow Surg 2018; 27:1357-1365. [PMID: 29776819 DOI: 10.1016/j.jse.2018.03.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 03/17/2018] [Accepted: 03/25/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Extension deformity of the distal humerus after a malunited supracondylar fracture can restrict elbow flexion. Here we report a computer-assisted operative procedure and review the results of clinical cases in which corrective surgery was performed. METHODS The medical records of the patients who underwent corrective osteotomy for hyperextended elbow malunion of the distal humerus with limited elbow flexion (flexion angle ≤100°) were reviewed retrospectively. Osteotomy was performed using patient-specific instruments designed based on preoperative 3-dimensional computer simulation. RESULTS Three patients, a 55-year-old woman and two 12-year-old boys, met the inclusion criteria. The angles of hyperextension of the affected distal humerus were 29°, 29°, and 25°, respectively. The range of flexion/extension of the elbow motion in the first patient improved from 95°/25° preoperatively to 140°/-10° postoperatively, in the second patient from 100°/20° to 145°/5°, and in the third patient from 80°/25° to 140°/10°. Bone union was achieved in all patients. There were no major complications. The corrective operations not only improved elbow flexion but also increased the total range of motion in the elbow by rebuilding the anterior curve of the distal humerus. CONCLUSIONS Correction of the extension deformity of the distal humerus after a malunited supracondylar fracture is a reasonable option for patients older than 10 years with restricted elbow flexion. Preoperative computer simulation and the use of patient-specific instruments can be a useful alternative that enables accurate deformity correction and improves the total range of motion.
Collapse
|
48
|
Three-dimensional scapular dyskinesis in hook-plated acromioclavicular dislocation including hook motion. J Shoulder Elbow Surg 2018; 27:1117-1124. [PMID: 29449083 DOI: 10.1016/j.jse.2017.12.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 12/08/2017] [Accepted: 12/12/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study is to analyze the 3-dimensional scapular dyskinesis and the kinematics of a hook plate relative to the acromion after hook-plated acromioclavicular dislocation in vivo. Reported complications of acromioclavicular reduction using a hook plate include subacromial erosion and impingement. However, there are few reports of the 3-dimensional kinematics of the hook and scapula after the aforementioned surgical procedure. METHODS We studied 15 cases of acromioclavicular dislocation treated with a hook plate and 15 contralateral normal shoulders using computed tomography in the neutral and full forward flexion positions. Three-dimensional motion of the scapula relative to the thorax during arm elevation was analyzed using a computer simulation program. We also measured the distance from the tip of the hook plate to the greater tuberosity, as well as the angular motion of the plate tip in the subacromial space. RESULTS Decreased posterior tilting (22° ± 10° vs 31° ± 8°) in the sagittal plane and increased external rotation (19° ± 9° vs 7° ± 5°) in the axial plane were evident in the affected shoulders. The mean values of translation of the hook plate and angular motion against the acromion were 4.0 ± 1.6 mm and 15° ± 8°, respectively. The minimum value of the distance from the hook plate to the humeral head tuberosity was 6.9 mm during arm elevation. CONCLUSIONS Acromioclavicular reduction using a hook plate may cause scapular dyskinesis. Translational and angular motion of the hook plate against the acromion could lead to subacromial erosion. However, the hook does not seem to impinge directly on the humeral head.
Collapse
|
49
|
Characteristics of Escherichia coli isolated from broiler chickens with colibacillosis in commercial farms from a common hatchery. Poult Sci 2018. [PMID: 28637225 DOI: 10.3382/ps/pex167] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
To investigate the epidemiologic aspects of colibacillosis in broiler chickens, 83 Escherichia coli isolates obtained from the pericarditis and perihepatitis lesions in broiler chickens from 4 commercial farms, 5 isolates recovered from 5 samples of yolk sac contents that were pooled from 25 emaciated chicks, and 4 fecal isolates obtained from a hatchery that supplied chicks to the 4 commercial farms mentioned above were genetically and bacteriologically characterized. Using pulsed-field gel electrophoresis (PFGE), a total of 92 isolates were classified into 33 pulsotypes. Identical pulsotypes were observed in isolates obtained from hatchery samples and the affected broiler chickens on multiple farms at various sampling times. Seventeen representative isolates with no common origin belonging to 6 pulsotypes and an additional 27 isolates with the other pulsotypes were used for further experiments. Isolates with identical pulsotypes exhibited common traits for virulence-associated genes, lipopolysaccharide core types, and phylogenetic groups. Nine of the isolates were serologically typed as O125 with various types of H antigens and 3 were typed as O25:H4. In the 27 isolates resistant to ceftiofur (CTF), which is a third generation cephalosporin, the blaCTX-M-2, blaCMY-2, blaCTX-M-14, blaCTX-M-65 genes were found in 15, 8, 3, and 1 isolate(s), respectively, and another isolate resistant to CTF had both the blaCTX-M-2 and the blaCMY-2 genes. In the 16 isolates with the blaCTX-M-2 gene, the chromosomal location of the gene was identified in 12 isolates. The plasmid-mediated quinolone resistance genes, oqxAB and aac(6')-Ib-cr, were found in 2 and 3 isolates, respectively. Conjugation experiments revealed that the blaCTX-M-2 (4 isolates), blaCTX-M-14 (3 isolates), blaSHV-12 (1 isolate), and oqxAB (2 isolates) genes were transferred. Our data suggest that E. coli strains with identical pulsotypes had been caused the incidences of colibacillosis and that the antimicrobial resistance genes on conjugative plasmids and those integrated into the chromosome may be spread among avian pathogenic E. coli strains in multiple farms.
Collapse
|
50
|
Administration of Oxygen Ultra-Fine Bubbles Improves Nerve Dysfunction in a Rat Sciatic Nerve Crush Injury Model. Int J Mol Sci 2018; 19:ijms19051395. [PMID: 29735961 PMCID: PMC5983615 DOI: 10.3390/ijms19051395] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Revised: 04/29/2018] [Accepted: 05/03/2018] [Indexed: 11/16/2022] Open
Abstract
Ultra-fine bubbles (<200 nm in diameter) have several unique properties and have been tested in various medical fields. The purpose of this study was to investigate the effects of oxygen ultra-fine bubbles (OUBs) on a sciatic nerve crush injury (SNC) model rats. Rats were intraperitoneally injected with 1.5 mL saline, OUBs diluted in saline, or nitrogen ultra-fine bubbles (NUBs) diluted in saline three times per week for 4 weeks in four groups: (1) control, (sham operation + saline); (2) SNC, (crush + saline); (3) SNC+OUB, (crush + OUB-saline); (4) SNC+NUB, (crush + NUB-saline). The effects of the OUBs on dorsal root ganglion (DRG) neurons and Schwann cells (SCs) were examined by serial dilution of OUB medium in vitro. Sciatic functional index, paw withdrawal thresholds, nerve conduction velocity, and myelinated axons were significantly decreased in the SNC group compared to the control group; these parameters were significantly improved in the SNC+OUB group, although NUB treatment did not affect these parameters. In vitro, OUBs significantly promoted neurite outgrowth in DRG neurons by activating AKT signaling and SC proliferation by activating ERK1/2 and JNK/c-JUN signaling. OUBs may improve nerve dysfunction in SNC rats by promoting neurite outgrowth in DRG neurons and SC proliferation.
Collapse
|