1
|
How do three-layer surgical masks prevent SARS-CoV-2 aerosol transmission? Sep Purif Technol 2023; 314:123574. [PMID: 36960012 PMCID: PMC10008175 DOI: 10.1016/j.seppur.2023.123574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 02/27/2023] [Accepted: 03/08/2023] [Indexed: 03/14/2023]
Abstract
The three-layer surgical mask was recognized by the World Health Organization as an effective-protection tool for reducing SARS-CoV-2 transmission during the COVID-19 pandemic; however, the contribution of each layer of this mask to the particle size-dependent filtration performance resistance remains unclear. Here, both experimental work and numerical simulation were conducted to study the role of each mask layer in particle size-dependent filtration and respiratory resistance. By using scanning electron microscopy images of a commercial three-layer mask, composed of two spun-bond and one melt-blown nonwoven polypropylene fabric layers, four representative models were constructed, in which the computational fluid dynamics of multiphase flow were performed. The pressure drop of all models under different flow conditions was measured next. Numerical simulation was then verified by comparing the experimental results in the present study and other theoretical works. The filtration efficiency of the spun-bond polypropylene nonwoven fabric layer was much lower than that of the melt-blown nonwoven polypropylene fabric layer for the particle diameter in the range of 0.1-2.0 μm. Both the spun-bond and melt-blown nonwoven polypropylene fabric layers demonstrated extremely low filtration efficiency for particles was<0.3 μm in diameter, with the maximum filtration efficiency being only 30%. The present results may facilitate rational design of mask products in terms of layer number and structural design.
Collapse
|
2
|
Experimental uncertainty assessment of meso- and microplastic concentrations in rivers based on net sampling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 870:161942. [PMID: 36731551 DOI: 10.1016/j.scitotenv.2023.161942] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/28/2022] [Accepted: 01/27/2023] [Indexed: 06/18/2023]
Abstract
Meso- and microplastics have been collected via net sampling in marine and freshwater environments, but the effect of net clogging on evaluations of their concentrations (mPC) remains uncertain. We experimentally investigated the mPC uncertainties resulting from net clogging in the Ohori and Tone-unga Rivers, typical urban rivers in Japan, throughout 16 samplings with five filtration durations in one day. The weighted mean concentration in the Ohori River was significantly lower than that in the Tone-unga River, allowing us to examine the effect of clogging in rivers with different contamination levels. The variances in both rivers consistently tended to increase with increasing filtration duration, which can be expressed by applying the integral form of the Weibull reliability function (WRF). Furthermore, application of the WRF successfully revealed the optimal filtration durations in the Ohori and Tone-unga Rivers, which depended on the plastic abundance and sample volume. Since it could be difficult to obtain the plastic contamination level in advance, our suggestion is to predict the time sustained above 85 % filtration efficiency by applying a WRF-based model. In actuality, the sustained time in the Ohori (Tone-unga) River varied between 2.6 and 6.2 min (3.2 and 7.1 min) throughout the experiment, which permitted low mPC uncertainties of 12 % and 9.5 %, respectively. If notable uncertainty exists due to a low contamination level, a net with a high open area ratio should be used to increase the filtration duration. Hence, our results emphasize the importance of considering the open area ratio of nets used for sampling in studies. Our study provides insights into the occurrence of uncertainty due to net clogging to establish a standardized methodology for meso- and microplastic monitoring in aquatic environments via net sampling and consequently contributes to improving the sampling accuracy.
Collapse
|
3
|
Face mask performance related to potentially infectious aerosol particles, breathing mode and facial leakage. Int J Hyg Environ Health 2023; 248:114103. [PMID: 36525701 PMCID: PMC9748312 DOI: 10.1016/j.ijheh.2022.114103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/24/2022] [Accepted: 12/08/2022] [Indexed: 12/15/2022]
Abstract
During the COVID 19 pandemic, wearing certified Respiratory Protective Devices (RPDs) provided important means of protection against direct and indirect infections caused by virus-laden aerosols. Assessing the RPD performance associated with infection prevention in standardised certification tests, however, faces drawbacks, such as the representativeness of the test aerosols used, the protection of third parties during exhalation or the effect of facial leaks. To address these drawbacks, we designed a novel test bench to measure RPD performance, namely the number based total efficiency, size-segregated fractional filtration efficiency and net pressure loss, for 11 types of certified surgical masks and Filtering Face Pieces dependent on breathing mode and facial fit. To be representative for the context of potentially infectious particles, we use a test aerosol based on artificial saliva that is in its size distribution similar to exhaled aerosols. In inhalation mode excluding facial leaks, all investigated samples deposit by count more than 85% of artificial saliva particles, which suggests a high efficiency of certified RPD filter media related to these particles. In exhalation mode most RPDs tend to have similar efficiencies but lower pressure losses. This deviation tends to be significant primarily for the RPDs with thin filter layers like surgical masks or Filtering Face Pieces containing nanofibers and may depend on the RPDs shape. Both the filtration efficiency and pressure loss are strongly inter-dependent and significantly lower when RPDs are naturally fitted including facial leaks, leading to a wide efficiency range of approximately 30-85%. The results indicate a much greater influence of the facial fit than the filter material itself. Furthermore, RPDs tend be more effective in self-protection than in third-party protection, which is inversely correlated to pressure loss. Comparing different types of RPDs, the pressure loss partially differs at similar filtration efficiencies, which points out the influence of the material and the filter area on pressure loss.
Collapse
|
4
|
The anti SARS-CoV-2 activity of nanofibrous filter materials activated with metal clusters. ATMOSPHERIC ENVIRONMENT: X 2023; 17:100212. [PMID: 36915669 PMCID: PMC9984305 DOI: 10.1016/j.aeaoa.2023.100212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 03/01/2023] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
Nanofibrous filter materials were prepared by electrospinning a solution of 28 wt% poly(vinylidene fluoride) in N,N-dimethylacetamide with and without the addition of 2 wt% AgNO3, Cu(NO3)2·2.5H2O or ZnCl2. X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy, inductively coupled plasma mass spectroscopy, thermogravimetric analysis, contact angle measurement, nitrogen sorption, and mercury intrusion porosimetry methods were used for the characterization of physical structure as well as the chemical composition of the electrospun materials. Particle filtration efficiency and antiviral activity against the SARS-CoV-2 alpha variant were tested in order to estimate the suitability of the prepared electrospun filter materials for application as indoor air filtration systems with virucidal properties. All filter materials prepared with salts demonstrated very high particle filtration efficiency (≥98.0%). The best antiviral activity was demonstrated by a material containing Cu(NO3)2·2.5H2O in the spinning solution, which displayed the decrease in the number of infectious virions by three orders of magnitude after a contact time of 12 h. Materials with the addition of AgNO3 and ZnCl2 decreased the number of infectious virions after the same contact time by only ∼8 and ∼11 times, respectively.
Collapse
|
5
|
Decontamination Assessment of Nanofiber-based N95 Masks. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:80411-80421. [PMID: 35716305 PMCID: PMC9206400 DOI: 10.1007/s11356-022-20903-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 09/30/2021] [Indexed: 06/15/2023]
Abstract
As the world battles with the outbreak of the novel coronavirus, it also prepares for future global pandemics that threaten our health, economy, and survivor. During the outbreak, it became evident that use of personal protective equipment (PPE), specially face masks, can significantly slow the otherwise uncontrolled spread of the virus. Nevertheless, the outbreak and its new variants have caused shortage of PPE in many regions of the world. In addition, waste management of the enormous economical and environmental footprint of single use PPE has proven to be a challenge. Therefore, this study advances the theme of decontaminating used masks. More specifically, the effect of various decontamination techniques on the integrity and functionality of nanofiber-based N95 masks (i.e. capable of at least filtering 95% of 0.3 μm aerosols) were examined. These techniques include 70% ethanol, bleaching, boiling, steaming, ironing as well as placement in autoclave, oven, and exposure to microwave (MW) and ultraviolet (UV) light. Herein, filtration efficiency (by Particle Filtration Efficiency equipment), general morphology, and microstructure of nanofibers (by Field Emission Scanning Electron microscopy) prior and after every decontamination technique were observed. The results suggest that decontamination of masks with 70% ethanol can lead to significant unfavorable changes in the microstructure and filtration efficiency (down to 57.33%) of the masks. In other techniques such as bleaching, boiling, steaming, ironing and placement in the oven, filtration efficiency dropped to only about 80% and in addition, some morphological changes in the nanofiber microstructure were seen. Expectedly, there was no significant reduction in filtration efficiency nor microstructural changes in the case of placement in autoclave and exposure to the UV light. It was concluded that, the latter methods are preferable to decontaminate nanofiber-based N95 masks.
Collapse
|
6
|
Can disposable masks be worn more than once? ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2022; 242:113908. [PMID: 35872486 PMCID: PMC9301359 DOI: 10.1016/j.ecoenv.2022.113908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 07/11/2022] [Accepted: 07/18/2022] [Indexed: 06/15/2023]
Abstract
Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks. The FFEs of masks were compared following extended wearing with and without washing. Results reveal that most disposable facemasks can retain a high level of their baseline FFE after extended wearing, even after 40 h of wearing. Laundering disposable masks degraded FFE in some instances. We conclude that the durability of disposable facemask performance is considerably longer than their intended single use indication, suggesting that reusing disposable masks is a safe means of reducing plastic waste in the environment.
Collapse
|
7
|
Evaluating the filtration efficiency of close-coupled catalyzed gasoline particulate filter (cGPF) over the WLTC and simulated RDE cycles. CHEMOSPHERE 2022; 301:134717. [PMID: 35487355 DOI: 10.1016/j.chemosphere.2022.134717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 04/06/2022] [Accepted: 04/21/2022] [Indexed: 06/14/2023]
Abstract
Gasoline particulate filter (GPF) is a cost-effective solution to particle number emissions from gasoline direct injection vehicles. Filtration efficiency, as a key parameter of GPF, was usually assessed at chassis level over regulatory drive cycles. However, the promulgation of real driving emission (RDE) requirements in the EU and Chinese regulations necessitates evaluations based on non-legislative cycles to guarantee the on-road emissions are compliant to regulatory requirements. In this research, two aggressive drive cycles, RTS95 at 23degC and modified RDE at 0degC, were complemented to the WLTC to evaluate the filtration efficiency of a catalyzed GPF (cGPF) in fresh conditions to obtain the so-called "worst-case" filtration efficiency. In the WLTC, RTS95, and simulated RDE tests, the filtration efficiency of the test cGPF was 51.1%, 41.3%, and 85.1% respectively. In the simulated RDE test, the test cGPF filtrated solid particles with a diameter above 23 nm and 10 nm at a similar efficiency. Increased filtration efficiency with heavier soot load could offset the relatively low filtration efficiency in cold-start and warm-up durations, hence the filtration efficiency for a clean cGPF showed higher sensitivity to cycle length over driving dynamics and testing temperature. In acceleration events with cGPF mounted, the particle diameter where number concentration peaked decreased as the engine warmed up. In deceleration events, bimodal and trimodal particle number size distributions with much lower concentrations were observed.
Collapse
|
8
|
The Effect of Hypochlorous Acid on the Filtration Performance and Bacterial Decontamination of N95 Filtering Facemask Respirators. Am J Infect Control 2022; 51:396-400. [PMID: 35870660 DOI: 10.1016/j.ajic.2022.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Stabilized Hypochlorous acid (HOCl) is increasingly used as a hospital disinfectant and antiseptic, yet its effect on N95 filtration facemask respirators (FFR) is unknown. These FFRs could also contribute to fomite-based transmission of nosocomial infections if worn for extended use between patient rooms. METHODS Filtration performance of N95 FFR fabric swatches was assessed after various levels of HOCl exposure. N95 swatches were then contaminated with 108 E. coli or 108 Staph aureus and treated with HOCl solution, 70% ethyl alcohol, or normal saline. Surviving bacterial numbers were assessed by plate counts. RESULTS The size-dependent filtration efficiency of HOCl-sprayed N95 FFR fabric ranged from 96 to 100%, showing no significant change. Flow resistance testing revealed almost no change compared to control. Submersion in HOCl, but not spraying, had an excellent bactericidal effect on contaminated swatches. DISCUSSION The role of the outer hydrophobic layer of N95 FFRs is discussed regarding the effects of HOCl on filtration and bacterial decontamination. CONCLUSION N95 material, sprayed with or briefly submerged in HOCl, maintained its filtration function. HOCl delivery by spray pump, however, would not accomplish decontamination of extended use FFRs between patient encounters. HOCl submersion of intact FFRs, contaminated with various hospital pathogens, is worth further study.
Collapse
|
9
|
Polymersomes as virus-surrogate particles for evaluating the performance of air filter materials. GIANT (OXFORD, ENGLAND) 2022; 10:100104. [PMID: 35600793 PMCID: PMC9116050 DOI: 10.1016/j.giant.2022.100104] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/16/2022] [Accepted: 05/16/2022] [Indexed: 05/15/2023]
Abstract
The development of antivirus air filter materials has attracted considerable interests due to the pandemic of coronavirus disease 2019 (COVID-19). Filtration efficiency (FE) of these materials against virus is critical in the assessment of their use in disease prevention. Due to the high cost and biosafety laboratory required for conducting research using actual virus samples, surrogates for virus are commonly used in the filtration test. Here, we explore the employment of polymersomes (polymeric vesicles) as a new type of surrogate. The polymersomes are hollow shell nanoparticles with amphiphilic bilayer membranes, which can be fabricated in nanosized, and possess similar size and structural features to virus. The performance of commercial KN95 mask and surgical mask with micro-sized fibers, and electrospun polyvinylidene fluoride (PVDF) and polyacrylonitrile (PAN) nanofibers were chosen to be evaluated. The filtration tests against fluorescent-labeled virus-surrogate particles (VSPs), i.e. polymersomes, allowed the determination of the FE of the multilayered filter materials in a layer-specific manner. The results suggested the importance of hydrophobicity in designing the nanofibrous filter materials. The employment of VSPs in filtration performance evaluation allows a cost-effective way to estimate the FE against virus, providing guidance on future development of air filter materials.
Collapse
|
10
|
Comparison of filtration efficiency and respiratory resistance of COVID-19 protective masks by multi-national standards. Am J Infect Control 2022; 50:516-524. [PMID: 35158009 PMCID: PMC8832847 DOI: 10.1016/j.ajic.2022.02.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 02/04/2022] [Accepted: 02/07/2022] [Indexed: 11/20/2022]
Abstract
Background Face masks from worldwide satisfy different standards during the COVID-19 pandemic, which led to the public misunderstanding of the concepts. Methods We systematically evaluated the quality of face masks provided by different companies according to multi-national standards, including EN 149-2001+A1: 2009, GB 2626-2019 and NIOSH 42 CFR Part 84-2019, focusing particularly on the particulate filtration efficiency (PFE) and respiratory resistance performance. Results Three types of masks (planar, folding and cup type masks) were measured based on different standard protocols. The results indicated that the PFE of the mask decreased in sequence of folding mask ≈ cup type mask > planar mask. The respiratory resistance of the masks ranked as follows: cup type mask > folding mask> planar mask. Overall, when PFE was used as the quality indicator, all the masks have a higher chance of meeting criteria of the EN149-2001+A1:2009, followed by the stricter standard set by the GB2626-2019 and NIOSH 42 CFR Part84-2019. Conversely, the respiratory resistance of the masks fulfilled the highest requirement of the EN149-2001+A1:2009 standard, while it is easier to satisfied the standard of GB 2626-2019 and NIOSH 42 CFR Part 84-2019. Conclusions We believe that our study provides effective guidance for customers worldwide to choose proper face masks under different epidemic situations.
Collapse
|
11
|
Filtering efficiency model that includes the statistical randomness of non-woven fiber layers in facemasks. Sep Purif Technol 2022; 282:120049. [PMID: 34744488 PMCID: PMC8558106 DOI: 10.1016/j.seppur.2021.120049] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 10/18/2021] [Accepted: 10/28/2021] [Indexed: 12/15/2022]
Abstract
Facemasks have become important tools to fight virus spread during the recent COVID-19 pandemic, but their effectiveness is still under debate. We present a computational model to predict the filtering efficiency of an N95-facemask, consisting of three non-woven fiber layers with different particle capturing mechanisms. Parameters such as fiber layer thickness, diameter distribution, and packing density are used to construct two-dimensional cross-sectional geometries. An essential and novel element is that the polydisperse fibers are positioned randomly within a simulation domain, and that the simulation is repeated with different random configurations. This strategy is thought to give a more realistic view of practical facemasks compared to existing analytical models that mostly assume homogeneous fiber beds of monodisperse fibers. The incompressible Navier-Stokes and continuity equations are used to solve the velocity field for various droplet-laden air inflow velocities. Droplet diameters are ranging from 10 nm to 1.0 µm, which covers the size range from the SARS-CoV-2 virus to the large virus-laden airborne droplets. Air inflow velocities varying between 0.1 m·s-1 to 10 m·s-1 are considered, which are typically encountered during expiratory events like breathing, talking, and coughing. The presented model elucidates the different capturing efficiencies (i.e., mechanical and electrostatic filtering) of droplets as a function of their diameter and air inflow velocity. Simulation results are compared to analytical models and particularly compare well with experimental results from literature. Our numerical approach will be helpful in finding new directions for anti-viral facemask optimization.
Collapse
|
12
|
Electrospun nanofiber-based respiratory face masks-a review. EMERGENT MATERIALS 2022; 5:261-278. [PMID: 35098033 PMCID: PMC8788396 DOI: 10.1007/s42247-022-00350-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/19/2022] [Indexed: 05/05/2023]
Abstract
The severe acute respiratory syndrome coronavirus (SARS-CoV-2) pandemic of 2019 forced widespread use of face coverings as a mandatory step towards reducing infection by the virus. The face mask acts as a barrier for transmission of infected aerosols among its user and surrounding people. This has propelled pace of research and development of face masks around the world. This short review is an effort to present advances in materials and designs used for face masks. Details available in scientific literature and company brochures have been accessed and the use of nanomaterials and designs for the new generation of face masks have been discussed. Special attention was given to the face masks based on electrospun nanofiber-based membrane materials due to their nano-sized pores, light weight, and high filtration efficiency; therefore, they are commercially viable and popular among various products available in the market. Incorporation of metal organic framework (MOFs) and graphene have opened avenues to more advanced/multi-functional, reusable, and high capacity adsorption filtration membranes. Rapid prototyping/3-dimensional (3-D) printing techniques have been applied to shorten the time of manufacture of face masks. This review is expected to be very helpful for engineers, scientists, and entrepreneurs working on development of novel face masks required in plenty during this pandemic period.
Collapse
|
13
|
Filtration of submicron dust by a dual-layer granular bed filter with an external electric field. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:48967-48983. [PMID: 33939088 DOI: 10.1007/s11356-021-12900-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 02/08/2021] [Indexed: 06/12/2023]
Abstract
To improve the filtration efficiency of submicron dust by dual-layer granular bed filters, filtration experiments for micro-silica powder were conducted for removing particles smaller than 1 μm that account for more than 96% (by volume) using a dual-layer granular bed filter with an external electric field. Electrostatic enhancement methods, including dust pre-charging, application of an electric field to the lower filter layer, and that to both the upper and lower filter layers, were examined. Results showed that the average filtration efficiency of a dual-layer granular bed filter for micro-silica powder without electric field was 76.52%, the average outlet dust concentration was 263.53 mg/m3, and the filtration cycle time was 73 min. With pre-charged dust, the average outlet dust concentration dropped to 82.51 mg/m3. A decrease in the thickness of the lower filter layer from 45 to 25 mm with electric field reduced the pressure drop from 2570 to 1770 Pa. Meanwhile, the application of an electric field to the lower/upper filter layer reduced the average outlet dust concentration to 25.98 mg/m3. Increasing the initial face velocity from 0.25 to 0.45 m/s increased the average outlet dust concentration from 25.98 to 30.27 mg/m3 and increased the pressure drop from 2570 to 3500 Pa.
Collapse
|
14
|
In Silico Hemodynamics and Filtering Evaluation of a Commercial Embolic Protection Device. Ann Biomed Eng 2021; 49:2659-2670. [PMID: 34405319 DOI: 10.1007/s10439-021-02846-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Accepted: 08/01/2021] [Indexed: 10/20/2022]
Abstract
During the last years, several kinds of Embolic Protection Devices (EPD) have been developed, with the aim of minimizing complication caused by thrombi generated during Carotid Artery Stenting (CAS). These devices are capable of capturing small particles generated during the intervention, avoiding cerebral stroke and improving the outcomes of the surgery. However, they have associated complications, like the increase on flow resistance associated by their use or the lack of knowledge on their actual filtration efficiency for thrombi of low size. Current work proposes a validated computational methodology in order to predict the hemodynamic features and filtering efficiency of a commercial EPD. It will be observed how Computational Fluid Dynamics predicts pressure drop with fair agreement with the experimental measurements. Finally, this work analyzes the filtration efficiency and the influence of the distribution of injected particles on this parameter. The capabilities of the filter for retaining particles of diameter below the pore size is, additionally, discussed.
Collapse
|
15
|
Assessment of the impact of multiple mild-steam decontaminations on the protection performance of disposable KN95 filtering facepiece respirators. Infect Prev Pract 2021; 3:100136. [PMID: 34368748 PMCID: PMC8336038 DOI: 10.1016/j.infpip.2021.100136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Indexed: 11/16/2022] Open
Abstract
The COVID-19 pandemic caused tremendous supply bottlenecks of single-use filtering facepiece respirators (FFRs) leading to a growing need for a potential reuse. This study assesses the impact of multiple mild-steam decontaminations with 121 °C/2000 mbar/20 min on the protection performance of disposable FFRs. It focuses on FFRs of type KN95 that is recently dominating the markets, but its decontamination is not covered in the literature. It was found that up to ten cycles, only minor degradation in the filter efficiency, breathing resistance and none in the material structure is apparent, suggesting a potential for multiple decontamination cycles at almost unchanged protective properties of KN95 FFRs.
Collapse
|
16
|
Additively manufactured respirators: quantifying particle transmission and identifying system-level challenges for improving filtration efficiency. JOURNAL OF MANUFACTURING SYSTEMS 2021; 60:762-773. [PMID: 33551537 PMCID: PMC7846466 DOI: 10.1016/j.jmsy.2021.01.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/07/2021] [Accepted: 01/08/2021] [Indexed: 05/09/2023]
Abstract
The COVID-19 pandemic has disrupted the supply chain for personal protective equipment (PPE) for medical professionals, including N95-type respiratory protective masks. To address this shortage, many have looked to the agility and accessibility of additive manufacturing (AM) systems to provide a democratized, decentralized solution to producing respirators with equivalent protection for last-resort measures. However, there are concerns about the viability and safety in deploying this localized download, print, and wear strategy due to a lack of commensurate quality assurance processes. Many open-source respirator designs for AM indicate that they do not provide N95-equivalent protection (filtering 95% of SARS-CoV-2 particles) because they have either not passed aerosol generation tests or not been tested. Few studies have quantified particle transmission through respirator designs outside of the filter medium. This is concerning because several polymer-based AM processes produce porous parts, and inherent process variation between printers and materials also threaten the integrity of tolerances and seals within the printed respirator assembly. No study has isolated these failure mechanisms specifically for respirators. The goal of this paper is to measure particle transmission through printed respirators of different designs, materials, and AM processes. The authors compare the performance of printed respirators to N95 respirators and cloth masks. Respirators in this study printed using desktop- and industrial-scale fused filament fabrication processes and industrial-scale powder bed fusion processes were not sufficiently reliable for widespread distribution and local production of N95-type respiratory protection. Even while assuming a perfect seal between the respirator and the user's face, although a few respirators provided >90% efficiency at the 100-300 nm particle range, almost all printed respirators provided <60% filtration efficiency. Post-processing procedures including cleaning, sealing surfaces, and reinforcing the filter cap seal generally improved performance, but the printed respirators showed similar performance to various cloth masks. The authors further explore the process-driven aspects leading to low filtration efficiency. Although the design/printer/material combination dictates the AM respirator performance, the identified failure modes originate from system-level constraints and are therefore generalizable across multiple AM processes. Quantifying the limitations of AM in producing N95-type respiratory protective masks advances understanding of AM systems toward the development of better part and machine designs to meet the needs of reliable, functional, end-use parts.
Collapse
|
17
|
An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration. Bioact Mater 2021; 6:106-122. [PMID: 32817918 PMCID: PMC7426537 DOI: 10.1016/j.bioactmat.2020.08.002] [Citation(s) in RCA: 146] [Impact Index Per Article: 48.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 08/01/2020] [Accepted: 08/02/2020] [Indexed: 12/12/2022] Open
Abstract
The masks have always been mentioned as an effective tool against environmental threats. They are considered as protective equipment to preserve the respiratory system against the non-desirable air droplets and aerosols such as the viral or pollution particles. The aerosols can be pollution existence in the air, or the infectious airborne viruses initiated from the sneezing, coughing of the infected people. The filtration efficiency of the different masks against these aerosols are not the same, as the particles have different sizes, shapes, and properties. Therefore, the challenge is to fabricate the filtration masks with higher efficiency to decrease the penetration percentage at the nastiest conditions. To achieve this concept, knowledge about the mechanisms of the penetration of the aerosols through the masks at different effective environmental conditions is necessary. In this paper, the literature about the different kinds of face masks and respiratory masks, common cases of their application, and the advantages and disadvantages of them in this regard have been reviewed. Moreover, the related mechanisms of the penetration of the aerosols through the masks are discussed. The environmental conditions affecting the penetration as well as the quality of the fabrication are studied. Finally, special attention was given to the numerical simulation related to the different existing mechanisms.
Collapse
|
18
|
Recent developments in filtration media and respirator technology in response to COVID-19. MRS BULLETIN 2021; 46:822-831. [PMID: 34539059 PMCID: PMC8442655 DOI: 10.1557/s43577-021-00173-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 08/06/2021] [Indexed: 05/03/2023]
Abstract
ABSTRACT The COVID-19 pandemic triggered a surge in demand for N95 or equivalent respirators that the global supply chain was unable to satisfy. This shortage in critical equipment has inspired research that addresses the immediate problems and has accelerated the development of the next-generation filtration media and respirators. This article provides a brief review of the most recent work with regard to face respirators and filtration media. We discuss filtration efficiency of the widely utilized cloth masks. Next, the sterilization of and reuse of existing N95 respirators to extend the existing stockpile is discussed. To expand near-term supplies, optimization of current manufacturing methods, such as melt-blown processes and electrospinning, has been explored. Future manufacturing methods have been investigated to address long-term supply shortages. Novel materials with antiviral and sterilizable properties with the ability for multiple reuses have been developed and will contribute to the development of the next generation of longer lasting multi-use N95 respirators. Finally, additively manufactured respirators are reviewed, which enable a rapidly deployable source of reusable respirators that can use any filtration fabric.
Collapse
|
19
|
Meltblown fabric vs nanofiber membrane, which is better for fabricating personal protective equipments. Chin J Chem Eng 2020; 36:1-9. [PMID: 33250602 PMCID: PMC7682934 DOI: 10.1016/j.cjche.2020.10.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/19/2020] [Accepted: 10/26/2020] [Indexed: 11/07/2022]
Abstract
The coronavirus disease 2019 (COVID-19) pandemic has led to a great demand on the personal protection products such as reusable masks. As a key raw material for masks, meltblown fabrics play an important role in rejection of aerosols. However, the electrostatic dominated aerosol rejection mechanism of meltblown fabrics prevents the mask from maintaining the desired protective effect after the static charge degradation. Herein, novel reusable masks with high aerosols rejection efficiency were fabricated by the introduction of spider-web bionic nanofiber membrane (nano cobweb-biomimetic membrane). The reuse stability of meltblown and nanofiber membrane mask was separately evaluated by infiltrating water, 75% alcohol solution, and exposing under ultraviolet (UV) light. After the water immersion test, the filtration efficiency of meltblown mask was decreased to about 79%, while the nanofiber membrane was maintained at 99%. The same phenomenon could be observed after the 75% alcohol treatment, a high filtration efficiency of 99% was maintained in nanofiber membrane, but obvious negative effect was observed in meltblown mask, which decreased to about 50%. In addition, after long-term expose under UV light, no filtration efficiency decrease was observed in nanofiber membrane, which provide a suitable way to disinfect the potential carried virus. This work successfully achieved the daily disinfection and reuse of masks, which effectively alleviate the shortage of masks during this special period.
Collapse
|
20
|
Improving konjac glucomannan-based aerogels filtration properties by combining aerogel pieces in series with different pore size distributions. Int J Biol Macromol 2020; 166:1499-1507. [PMID: 33181223 DOI: 10.1016/j.ijbiomac.2020.11.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/02/2020] [Accepted: 11/06/2020] [Indexed: 12/01/2022]
Abstract
The pore size distribution of konjac glucomannan (KGM)-based aerogels seriously impacted the air filtration efficiency and filtration resistance. This study aimed to investigate the pore size distribution control of KGM-based aerogels through total solid concentration of the sol and to improve the filtration performance by preparing aerogel stacks, which were made by combining KGM-based aerogels with different pore size distribution (range: 0-180 μm). Results indicated that with increased total solid concentration from 50% to 100% of the origin formulae, aerogel pore size became smaller and the porosity was decreased for all the three sample formulae. Meanwhile, the aerogel mechanical property and filtration efficiency were both strengthened with increased total solid concentration, but the air resistance became significantly higher. The changing extent and rule were influenced by the sample components (KGM, starch, gelatin, wheat straw). The aerogel stacks prepared by in series combining the aerogel pieces with different pore size distribution (from large size to small size) was found to improve filtration efficiency (e.g. from 70% to 80% for K1G2S4WS2) and significantly lower the air resistance (e.g. from 270 Pa to 190 Pa for K1G2S4WS2). This study could guide the filtration performance improvement of aerogels.
Collapse
|
21
|
Universal masking during COVID-19 pandemic: Can textile engineering help public health? Narrative review of the evidence. Prev Med 2020; 139:106236. [PMID: 32795645 PMCID: PMC7418702 DOI: 10.1016/j.ypmed.2020.106236] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 08/07/2020] [Accepted: 08/09/2020] [Indexed: 12/29/2022]
Abstract
The Coronavirus Disease-2019 (COVID-19) pandemic caused by the virus SARS-CoV-2 is spreading very quickly around the world. In less than 7 months since it became known to the international community, the virus has infected 18 million in more than 180 countries and killing more than 700,000 people. Person-to-person transmission through infected respiratory droplets from patients with symptoms and asymptomatic carriers is the main mode of spread in the community. There is currently no standard agreed upon drug to treat the disease and the prospect of having a safe and efficacious vaccine might be years away. Thus, public health interventions such as social distancing and hand washing have been introduced and has, to some extent, slowed the progression of the pandemic. Universal masking as a public health intervention is currently mandatory in a vast majority of countries around the world. To avoid personal protective equipment (PPE) shortage crisis for medical staff and other frontline workers, health authorities are recommending the use cloth masks. Although in theory, cloth masks can be helpful to limit the spread of the COVID-19, serious consideration should be given to the choice of textile, the number of layers of cloth used, pre-treatment of the material with water repellent material and other compounds that can enhance the filtration efficiency of the masks without compromising their breathability. This review uses concepts of textile engineering and the theoretical principles of filtration to make suggestions and recommendations to improve the quality and safety of cloth masks for the general public.
Collapse
|
22
|
A fluid mechanics explanation of the effectiveness of common materials for respiratory masks. Int J Infect Dis 2020; 99:505-513. [PMID: 32861829 PMCID: PMC7452831 DOI: 10.1016/j.ijid.2020.07.066] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/22/2020] [Accepted: 07/26/2020] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVES Face masks are an important component of personal protection equipment employed in preventing the spread of diseases such as COVID-19. As the supply of mass-produced masks has decreased, the use of homemade masks has become more prevalent. It is important to quantify the effectiveness of different types of materials to provide useful information, which should be considered for homemade masks. METHODS Filtration effects of different types of common materials were studied by measuring the aerosol droplet concentrations in the upstream and downstream regions. Flow-field characteristics of surrounding regions of tested materials were investigated using a laser-diagnostics technique, i.e., particle image velocimetry. The pressure difference across the tested materials was measured. RESULTS Measured aerosol concentrations indicated a breakup of large-size particles into smaller particles. Tested materials had higher filtration efficiency for large particles. Single-layer materials were less efficient, but they had a low pressure-drop. Multilayer materials could produce greater filtering efficiency with an increased pressure drop, which is an indicator of comfort level and breathability. The obtained flow-fields indicated a flow disruption downstream of the tested materials as the velocity magnitude noticeably decreased. CONCLUSIONS The obtained results provide an insight into flow-field characteristics and filtration efficiency of different types of household materials commonly used for homemade masks. This study allows comparison with mass-produced masks under consistent test conditions while employing several well-established techniques.
Collapse
|
23
|
Home-made masks with filtration efficiency for nano-aerosols for community mitigation of COVID-19 pandemic. Public Health 2020; 188:42-50. [PMID: 33075669 PMCID: PMC7466940 DOI: 10.1016/j.puhe.2020.08.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 08/11/2020] [Accepted: 08/18/2020] [Indexed: 11/23/2022]
Abstract
Objectives The novel coronavirus disease 2019 (COVID-19) epidemic that emerged in December 2019 has rapidly evolved in recent months to become a worldwide and ongoing pandemic. Shortage of medical masks remains an unresolved problem. This study aims to investigate the filtration efficiency (FE) of home-made masks that could be used as alternatives for community mitigation of COVID-19. Study design Experimental observational analytic study. Methods The FE of home-made masks and medical masks (as the control) were tested under laminar flow within a scaled air duct system using nebulised NaCl aerosols sized 6–220 nm. The size-resolved NaCl aerosol count was measured using a scanning mobility particle-sizer spectrometer. Home-made masks with an external plastic face shield also underwent a splash test. In addition, the fibre structures of medical masks were studied under an electron microscope after treatment with either 75% alcohol or soap and water at 60 °C. Results The FE of the home-made masks at 6–200 nm were non-inferior to that of medical masks (84.54% vs 86.94%, P = 0.102). Both types of masks achieved an FE of 90% at 6–89 nm. A significantly higher FE was achieved when one piece of tissue paper was added adjacent to the inner surface of the medical mask than medical mask alone (6–200 nm: 91.64% vs 86.94%, P < 0.0001; 6–89 nm: 94.27% vs 90.54%, P < 0.0001; 90–200 nm: 82.69% vs 73.81%, P < 0.0001). The plastic face shield prevented the home-made mask from fluid splash. The fibre structures of the external surface of medical masks were damaged after treatment with either 75% alcohol or soap and water at 60 °C. Conclusions The home-made masks in this study, which were made of one piece of tissue paper and two pieces of kitchen towels, layered from face to external, had an FE at 6–200 nm non-inferior to that of medical mask materials, which had a certified FE of ≥95% at 3 μm. In the current COVID-19 pandemic with the shortage of medical masks, these home-made masks combined with an external plastic shield could be used as an alternative to medical masks for community mitigation. In addition, one piece of tissue paper could be placed adjacent to the inner surface of a medical mask to prolong effective lifespan of the medical mask. These demand reduction strategies could be used to reserve medical masks for use in healthcare and certain high-risk community settings, such as symptomatic persons, caregivers and attendees to healthcare institutions. Our home-made masks have filtration efficiency comparable to medical masks. They may be used as alternatives in low-risk community settings. Plastic face shields may be used in situations when social distancing and/or face masks are not feasible. Decontamination of medical masks with 75% alcohol or soap and water damages the fibres and is not recommended. Community mitigation measures are an important part of the global efforts in combating COVID-19.
Collapse
|
24
|
Preparation and characterization of triple layer membrane for water filtration. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:29717-29724. [PMID: 31446599 DOI: 10.1007/s11356-019-06254-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 08/16/2019] [Indexed: 06/10/2023]
Abstract
Triple layer membranes of different proportions were prepared by using the combination of electrospinning and dry-wet phase inversion technique. The polymer solution of Nylon/PEG was prepared and poured over the electrospun polyacrylonitrile (PAN) nanofibers. Thus, prepared triple layer membranes were characterized by optical microscope, scanning electron microscope, porosimeter, X-ray diffraction, and thermogravimetric analyzer to study the morphology, pore size distribution, crystallinity, and degradation properties respectively. The performance of the triple layer membranes was evaluated by pure water flux and filtration efficiency. The results revealed that the triple layer membrane with the proportion of 60/40 (Nylon/PEG) has optimal pure water flux and higher filtration efficiency than the other prepared triple layer membranes.
Collapse
|
25
|
The face mask: How a real protection becomes a psychological symbol during Covid-19? Brain Behav Immun 2020; 88:1-5. [PMID: 32526447 PMCID: PMC7833005 DOI: 10.1016/j.bbi.2020.05.060] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 05/21/2020] [Accepted: 05/21/2020] [Indexed: 01/22/2023] Open
Abstract
'The Mask' has become a byword and a precious possession universally. Except for its use by the medical fraternity, answers to the common questions-whether it provides enough protection, which type is optimal for the general public and who really needs to don it, remain poorly understood. For a frontline healthcare worker, wearing mask is a necessity as an important person protection equipment, it is perhaps the most-powerful psychological symbol for the general public. Surprisingly, it even undermines all other recommended practices of infection control and breaking the transmission chain of Covid-19, like hand washing, personal hygiene and social distancing. 'The mask' has evolved with time and yet there is a need to further improve the design for safety, tolerability and comfort. In this review we present the journey of face mask, originating from the first masks aimed at stopping the bad smell to its industrial use to its all-important place in the medical field. Various types of face masks, their filtration efficiency, reusability and current recommendations for their use are presented.
Collapse
|
26
|
Filtration performances of non-medical materials as candidates for manufacturing facemasks and respirators. Int J Hyg Environ Health 2020; 229:113582. [PMID: 32917368 PMCID: PMC7373391 DOI: 10.1016/j.ijheh.2020.113582] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 06/15/2020] [Accepted: 06/15/2020] [Indexed: 11/25/2022]
Abstract
The recent outbreak of the coronavirus disease (COVID-19) is causing a shortage of personal protective equipment (PPE) in different countries around the world. Because the coronavirus can transmit through droplets and aerosols, facemasks and N95 respirators that require complex certification, are urgently needed. Given the situation, the U.S. Centers for Disease Control and Prevention (CDC) recommends that “in settings where facemasks are not available, healthcare personnel might use homemade masks (e.g., bandana, scarf) for the care of patients with COVID-19 as a last resort.” Although aerosols and droplets can be removed through the fibers of fabrics through a series of filtration mechanisms, their filtration performances have not been evaluated in detail. Moreover, there are a series of non-medical materials available on the market, such as household air filters, coffee filters, and different types of fabrics, which may be useful when facemasks and respirators are not available. In this study, we comprehensively evaluated the overall and size-dependent filtration performances of non-medical materials. The experiments were conducted under different face velocities to study its influence on size-dependent filtration performances. The flow resistance across these filter materials is measured as an indicator of the breathability of the materials. The results illustrate that multiple layers of household air filters are able to achieve similar filtration efficiencies compared to the N95 material without causing a significant increase in flow resistance. Considering that these air filters may shed micrometer fibers during the cutting and folding processes, it is recommended that these filters should be inserted in multiple layers of fabrics when manufacturing facemasks or respirators. Agencies suggest the manufacturing of homemade face masks during COVID-19. This work examined a wide range of non-medical materials for their filtration performance. We studied the influences of face velocity, number of filter material layers, and the size-dependent filtration efficiency. Several layers of household air filters can achieve similar filtration performance compared to N95 materials. The information will be crucial for healthcare personnel and the general public in manufacturing homemade face masks.
Collapse
|
27
|
Re-use of health masks after autoclaving. NANOIMPACT 2020; 19:100231. [PMID: 33521385 PMCID: PMC7832556 DOI: 10.1016/j.impact.2020.100231] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 05/06/2020] [Accepted: 05/16/2020] [Indexed: 05/14/2023]
Abstract
With the rapid global spread of the new coronavirus and risk of pneumonia from COVID-19 infection, wearing a mask has become an essential defense for all frontline doctors, nurses, and healthcare professionals. Plus, the rise in demand for masks from the general public means the worldwide supply of masks is insufficient, which has led to an increase in the reuse of disposable masks. Therefore, this study compared the impact of autoclaving (steaming) and 70% ethyl alcohol treatment for decontaminating masks, as both methods can easily be used at home. The autoclaved masks showed a better filtration efficiency than the 70% ethyl alcohol-treated masks. A further investigation of 8 used KF 94 masks (filtration efficiency >94%) also showed that autoclaving for decontamination was limited to two times. Moreover, a kitchen towel mask, a popular homemade alternative, did not show sufficient filtration efficiency.
Collapse
|
28
|
Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection. Polym Degrad Stab 2020; 179:109251. [PMID: 32834203 PMCID: PMC7271865 DOI: 10.1016/j.polymdegradstab.2020.109251] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 11/29/2022]
Abstract
The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Hence, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. An overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness. Thermal conditioning and gentle surface disinfection to aid extended use of masks. Adequate material properties for most masks to survive a few cycles at 75°C. Temperature control important, as conditioning is near the softening point for some of the plastics and fibers used. No measurable loss of mask filter performance after moderate thermal exposure or gentle application of surface disinfectant.
Collapse
|
29
|
Evaluation of filtration characteristics and microbial recovery rates of commercial filtering facepiece respirators against airborne bacterial particles. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 682:729-736. [PMID: 31141754 DOI: 10.1016/j.scitotenv.2019.05.153] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Revised: 04/24/2019] [Accepted: 05/11/2019] [Indexed: 06/09/2023]
Abstract
Many brands of filtering facepiece respirators are used against air pollution, including bioaerosols; however, studies have explored exposure to bioaerosols from the inside surfaces of respirators. We evaluated the filtration efficiencies and microbial recovery rates of commercial filtering facepiece respirators against bioaerosols. Eight filtering facepiece respirators and one surgical mask were selected, all with high market shares in the Republic of Korea and certified by national or international standards. The tested filtering facepiece respirators were installed on the head of a mannequin under various airflow velocity and relative humidity (RH) conditions. The filtration efficiency against Staphylococcus epidermidis and Escherichia coli bioaerosols, the pressure drop of the filter, and the relative recovery rates for the bacteria were evaluated. The filtration efficiency of each filtering facepiece respirator ranged from 82% to 99%, depending on the filtration grade. The pressure drop was significantly affected by variations in the surrounding RH. The mean relative recovery rates of all filtering facepiece respirators were 14 ± 4.8% and 9 ± 4.7% for S. epidermidis and E. coli, respectively. These results indicate that airborne microorganisms can survive and accumulate on the surfaces of filtering facepiece respirators, which may lead to harmful health outcomes. Our findings will be useful as background information for the development of commercial filtering facepiece respirators while considering their biological properties and reliable guidance to users.
Collapse
|
30
|
The effects of facemasks on airway inflammation and endothelial dysfunction in healthy young adults: a double-blind, randomized, controlled crossover study. Part Fibre Toxicol 2018; 15:30. [PMID: 29973251 PMCID: PMC6032602 DOI: 10.1186/s12989-018-0266-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 06/15/2018] [Indexed: 12/18/2022] Open
Abstract
Background Facemasks are increasingly worn during air pollution episodes in China, but their protective effects are poorly understood. We aimed to evaluate the filtration efficiencies of N95 facemasks and the cardiopulmonary benefits associated with wearing facemasks during episodes of pollution. Results We measured the filtration efficiencies of particles in ambient air of six types of N95 facemasks with a manikin headform. The most effective one was used in a double-blind, randomized, controlled crossover study, involving 15 healthy young adults, conducted during 2 days of severe pollution in Beijing, China. Subjects were asked to walk along a busy-traffic road for 2 h wearing authentic or sham N95 facemasks. Clinical tests were performed four times to determine changes in the levels of biomarkers of airway inflammation, endothelial dysfunction, and oxidative stress within 24 h after exposure. The facemasks removed 48–75% of number concentrations of ambient air particles between 5.6 and 560 nm in diameter. After adjustments for multiple comparison, the exhaled nitric oxide level and the levels of interleukin-1α, interleukin-1β, and interleukin-6 in exhaled breath condensate increased significantly in all subjects; however, the increases in those wearing authentic facemasks were statistically significantly lower than in the sham group. No significant between-group difference was evident in the urinary creatinine-corrected malondialdehyde level. In arterial stiffness indicators, the ejection duration of subjects wearing authentic facemasks was higher after exposure compared to the sham group; no significant between-group difference was found in augmentation pressure or the augmentation index. Conclusions In young healthy adults, N95 facemasks partially reduced acute particle-associated airway inflammation, but neither systemic oxidative stress nor endothelial dysfunction improved significantly. The clinical significance of these findings long-term remains to be determined. Trial registration The trial registration number (TRN) for this study is ChiCTR1800016099, which was retrospectively registered on May 11, 2018. Electronic supplementary material The online version of this article (10.1186/s12989-018-0266-0) contains supplementary material, which is available to authorized users.
Collapse
|
31
|
Separation of nanoparticles: Filtration and scavenging from waste incineration plants. WASTE MANAGEMENT (NEW YORK, N.Y.) 2016; 52:346-352. [PMID: 27067426 DOI: 10.1016/j.wasman.2016.03.050] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 02/16/2016] [Accepted: 03/28/2016] [Indexed: 06/05/2023]
Abstract
Increased amounts of nanoparticles are applied in products of everyday life and despite material recycling efforts, at the end of their life cycle they are fed into waste incineration plants. This raises the question on the fate of nanoparticles during incineration. In terms of environmental impact the key question is how well airborne nanoparticles are removed by separation processes on their way to the bag house filters and by the existing filtration process based on pulse-jet cleanable fibrous filter media. Therefore, we investigate the scavenging and the filtration of metal nanoparticles under typical conditions in waste incineration plants. The scavenging process is investigated by a population balance model while the nanoparticle filtration experiments are realized in a filter test rig. The results show that depending on the particle sizes, in some cases nearly 80% of the nanoparticles are scavenged by fly ash particles before they reach the bag house filter. For the filtration step dust cakes with a pressure drop of 500Pa or higher are found to be very effective in preventing nanoparticles from penetrating through the filter. Thus, regeneration of the filter must be undertaken with care in order to guarantee highly efficient collection of particles even in the lower nanometre size regime.
Collapse
|
32
|
Assessment of the risk of infectious aerosols leaking to the environment from BSL-3 laboratory HEPA air filtration systems using model bacterial aerosols. PARTICUOLOGY 2014; 13:82-87. [PMID: 38620193 PMCID: PMC7148691 DOI: 10.1016/j.partic.2012.11.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2012] [Revised: 09/14/2012] [Accepted: 11/21/2012] [Indexed: 06/10/2023]
Abstract
To assess the risk of infectious bacterial aerosols leaking to the environment, the filtration efficiency of a biosafety level 3 (BSL-3) laboratory high-efficiency particulate (HEPA) filter was investigated using the aerosolized bacteria Serratia marcescens. The aerosol size was measured using an Andersen sampler. Eight first stage HEPA filters (numbered 1-8) were distributed in contaminated labs and exhausts from each of the first stage HEPA filters were aggregated and filtered through one second stage HEPA filter before being released to the environment. In total, 8 first-stage and 1 second-stage HEPA filters from the BSL-3 air purification system were analyzed. No S. marcescens was detected in first stage filters 1, 2, 4, 5, 7 and 8 and the second stage HEPA filter. The filtration efficiencies against aerosolized S. marcescens were >99.9999%. First stage filter numbers 3 and 6 had filtration efficiencies of 99.9825% and 99.9906%, respectively. When filter number 3 was replaced by a new filter and the bracket for filter number 6 was sealed, no aerosolized S. marcescens was detected in the filtered air. Our work suggests that the BSL-3 laboratory HEPA filter air purification system is effective against bacterial aerosols, with little to no bacterial leakage into the environment.
Collapse
|
33
|
Determining the filtration efficiency of half-face medical protection mask (N99) against viral aerosol. AEROBIOLOGIA 2010; 26:245-251. [PMID: 32214626 PMCID: PMC7087622 DOI: 10.1007/s10453-010-9160-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2009] [Accepted: 03/23/2010] [Indexed: 05/14/2023]
Abstract
Hospital-based outbreaks of severe acute respiratory syndrome (SARS) have once again highlighted the vulnerability of healthcare workers (HCWs). Use of personal respiratory protective equipment was the main method used by HCWs to avoid nosocomial transmission. This paper describes the technology used to evaluate the filtration efficiency of the half-face medical protection mask (N99), manufactured by Firmshield Biotechnology, against viral aerosol. Viral aerosol was generated and then sampled simultaneously with and without the test mask. This enables a percentage efficiency value to be calculated against test phage f2 aerosols (surrogates of viral pathogen aerosols). At the same time the mask filtration efficiency against NaCl particle aerosol was determined by use of TSI8130 equipment and face-fit factor was tested by use of TSI8020 equipment. The half-face medical protection mask (N99) evaluated by use of the viral aerosol had a filtration efficiency >99%. The mask filtration efficiency against NaCl particle aerosol was 99.634 ± 0.024% and it had a good face-fit factor. This half-face medical protection mask (N99) can protect the wearer from viral aerosol disease transmission. The test method can be used to assess filtration efficacy against viral aerosol of masks used for respiratory protection.
Collapse
|