1
|
Optimizing Josephson Junction Reproducibility in 30 kV E-Beam Lithography: An Analysis of Backscattered Electron Distribution. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:783. [PMID: 38727377 PMCID: PMC11085180 DOI: 10.3390/nano14090783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 04/13/2024] [Accepted: 04/17/2024] [Indexed: 05/12/2024]
Abstract
This paper explores methods to enhance the reproducibility of Josephson junctions, which are crucial elements in superconducting quantum technologies, when employing the Dolan technique in 30 kV e-beam processes. The study explores the influence of dose distribution along the bridge area on reproducibility, addressing challenges related to fabrication sensitivity. Experimental methods include e-beam lithography, with electron trajectory simulations shedding light on the behavior of backscattered electrons. Wedescribe the fabrication of various Josephson junction geometries and analyze the correlation between the success rates of different lithography patterns and the simulated distribution of backscattered electrons. Our findings demonstrate a success rate of up to 96.3% for the double-resist 1-step low-energy e-beam lithography process. As a means of implementation strategy, we provide a geometric example that takes advantage of simulated stability regions to administer a controlled, uniform dose across the junction area, introducing novel features to overcome the difficulties associated with fabricating bridge-like structures.
Collapse
|
2
|
Structure-Related Electronic and Magnetic Properties in Ultrathin Epitaxial Ni xFe 3-xO 4 Films on MgO(001). NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:694. [PMID: 38668188 PMCID: PMC11053537 DOI: 10.3390/nano14080694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/11/2024] [Accepted: 04/13/2024] [Indexed: 04/29/2024]
Abstract
Off-stoichiometric NixFe3-xO4 ultrathin films (x < 2.1) with varying Ni content x and thickness 16 (±2) nm were grown on MgO(001) by reactive molecular beam epitaxy. Synchrotron-based high-resolution X-ray diffraction measurements reveal vertical compressive strain for all films, resulting from a lateral pseudomorphic adaption of the film to the substrate lattice without any strain relaxation. Complete crystallinity with smooth interfaces and surfaces is obtained independent of the Ni content x. For x < 1 an expected successive conversion from Fe3O4 to NiFe2O4 is observed, whereas local transformation into NiO structures is observed for films with Ni content x > 1. However, angle-resolved hard X-ray photoelectron spectroscopy measurements indicate homogeneous cationic distributions without strictly separated phases independent of the Ni content, while X-ray absorption spectroscopy shows that also for x > 1, not all Fe2+ cations are substituted by Ni2+ cations. The ferrimagnetic behavior, as observed by superconducting quantum interference device magnetometry, is characterized by decreasing saturation magnetization due to the formation of antiferromagnetic NiO parts.
Collapse
|
3
|
Spin Frustration in Organic Radicals. Angew Chem Int Ed Engl 2024; 63:e202310147. [PMID: 37767854 DOI: 10.1002/anie.202310147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/27/2023] [Accepted: 09/27/2023] [Indexed: 09/29/2023]
Abstract
Spin frustration, which results from geometric frustration and a systematical inability to satisfy all antiferromagnetic (AF) interactions between unpaired spins simultaneously, is under the spotlight for its importance in physics and materials science. Spin frustration is treated as the structural basis of quantum spin liquids (QSLs). Featuring flexible chemical structures, organic radical species exhibit great potential in building spin-frustrated molecules and lattices. So far, the reported examples of spin-frustrated organic radical compounds include triradicals, tetrathiafulvalene (TTF) radicals and derivatives, [Pd(dmit)2 ] compounds (dmit=1,3-dithiol-2-thione-4,5-dithiolate), nitronyl nitroxides, fullerenes, polycyclic aromatic hydrocarbons (PAHs), and other heterocyclic compounds where the spin frustration is generated intra- or intermolecularly. In this Minireview, we provide a brief summary of the reported radical compounds that possess spin frustration. The related data, including magnetic exchange coupling parameters, spin models, frustration parameters, and crystal lattices, are summarized and discussed.
Collapse
|
4
|
The Advantages of Non-Adhesive Gel-like Embolic Materials in the Endovascular Treatment of Benign Hypervascularized Lesions of the Head and Neck. Gels 2023; 9:954. [PMID: 38131940 PMCID: PMC10742558 DOI: 10.3390/gels9120954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 12/23/2023] Open
Abstract
OBJECTIVES The use of non-adhesive gel-like embolic materials (NAGLEMs) in the endovascular treatment of hypervascularized formations in the head and neck is gaining in popularity because of a number of important characteristics involved. Their primary benefits are their capacity to penetrate diseased vasculature, effectively distribute, and, most importantly, remain controllable during the process. We reviewed the literature and evaluated the results of using NAGLEMs in comparison to other embolizing substances (namely, coils, glue, and particles) as alternative embolizing agents for patients receiving care at our clinic. The process comprised evaluating the safety, effectiveness, and technological elements of endovascular therapy used to treat two categories of hypervascular pathological abnormalities that were surgically corrected between 2015 and 2023. Arteriovenous malformations (AVMs) located in the head, neck, and paragangliomas with jugular/carotid body localization are combined by intense shunting blood flow and shared requirements for the embolic agent used in endovascular treatment (such as penetration, distribution, delayed polymerization, and controllability). An analysis of the literature was also conducted. Results showed 18 patients diagnosed with neck paragangliomas of the carotid body and jugular type. Five patients with arteriovenous malformation (AVM) of the face and neck were included, consisting of sixteen females and seven males with an average age of 55 ± 13 years. Endovascular procedures were performed using NAGLEMs (ONYX (Medtronic, Irvine, CA, USA), SQUID (Balt, Montmorency, France), and PHIL (Microvention, Tustin, CA, USA)) and dimethyl sulfoxide (DMSO)-compatible balloon catheters. All patients achieved complete or partial embolization of hypervascularized formations using one or more stages of endovascular treatment. Additionally, three AVMs of the face and two paragangliomas of the neck were surgically excised following embolization. In other instances, formations were not deemed necessary to be removed. The patients' condition upon discharge was assessed by the modified Rankin Scale (mRs) and rated between 0 and 2. CONCLUSION Currently, NAGLEMs are predominantly used to treat hypervascularized formations in the neck and head due to their fundamental properties. These properties include a lack of adhesion and a delay in predictable polymerization (after 30-40 min). NAGLEMs also exhibit excellent distribution and penetration throughout the vascular bed of the formation. Adequate controllability of the process is largely achieved through the presence of embolism forms of different viscosity, as well as excellent X-ray visualization.
Collapse
|
5
|
Novel Characterization Techniques for Multifunctional Plasmonic-Magnetic Nanoparticles in Biomedical Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2929. [PMID: 37999283 PMCID: PMC10675523 DOI: 10.3390/nano13222929] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 11/02/2023] [Accepted: 11/08/2023] [Indexed: 11/25/2023]
Abstract
In the rapidly emerging field of biomedical applications, multifunctional nanoparticles, especially those containing magnetic and plasmonic components, have gained significant attention due to their combined properties. These hybrid systems, often composed of iron oxide and gold, provide both magnetic and optical functionalities and offer promising avenues for applications in multimodal bioimaging, hyperthermal therapies, and magnetically driven selective delivery. This paper focuses on the implementation of advanced characterization methods, comparing statistical analyses of individual multifunctional particle properties with macroscopic properties as a way of fine-tuning synthetic methodologies for their fabrication methods. Special emphasis is placed on the size-dependent properties, biocompatibility, and challenges that can arise from this versatile nanometric system. In order to ensure the quality and applicability of these particles, various novel methods for characterizing the magnetic gold particles, including the analysis of their morphology, optical response, and magnetic response, are also discussed, with the overall goal of optimizing the fabrication of this complex system and thus enhancing its potential as a preferred diagnostic agent.
Collapse
|
6
|
Embolization of brain arteriovenous malformations with squid co-polymer embolic material: Initial experience. J Interv Med 2023; 6:176-179. [PMID: 38312133 PMCID: PMC10831375 DOI: 10.1016/j.jimed.2023.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 09/27/2023] [Accepted: 09/27/2023] [Indexed: 02/06/2024] Open
Abstract
Objective To analyze the safety and effectiveness of the ethylene-vinyl alcohol copolymer (EVOH) liquid embolic agent Squid (Emboflu, Switzerland) for the treatment of brain arteriovenous malformations. Materials and procedures Between April 2015 and July 2017, 46 embolization treatments for brain arteriovenous malformations (BAVM) were performed in 25 patients using two Squid formulations (18 and 12). Six female and 19 male patients with a mean age of 34 years (range, 9-62 years) were included. A total of 46 procedures were performed. The BAVMs were classified as Spetzler-Martin grade II in 4 procedures, III in 27 procedures, and 1V in 15 procedures. Among the 25 patients, 15 presented with hemorrhage, 5 with seizures, and 5 with headache and neurology. The BAVMs were located in the temporal lobe in 5 patients, parietal lobe in 7 patients, frontal lobe in 3 patients, posterior fossa in 6 patients, basal ganglia in 3 patients, and parasagittal lobe in 1 patient. Results The obliteration rate of the BAVMs ranged from 10% to 100%, with a mean of 33%. Most patients underwent their first or second embolization procedure. Four patients (8%) developed intracranial bleeding post-procedure, with one death (2%). One patient (2%) experienced a seizure during the procedure; however, no intracranial bleeding was observed. Seven patients (15%) experienced perforations during catheter manipulation. One case (2%) of a fractured catheter was recorded, but no significant complications were observed. The average volume of copolymer injected was 0.6 ml per nidus. Thirteen procedures used the Squid-12 formulation, 29 procedures used the Squid-18 formulation, and 3 procedures used a combination of Squid-12 and -18 formulations. Conclusion Squid is a safe and effective embolic agent for treating BAVMs.
Collapse
|
7
|
Neuromuscular Magnetic Field Measurement Based on Superconducting Bio-Sensors. MICROMACHINES 2023; 14:1768. [PMID: 37763931 PMCID: PMC10535156 DOI: 10.3390/mi14091768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/08/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023]
Abstract
These years, disease-causing and disabling diseases have caused great concern. Neurological musculoskeletal disorders are diverse and affect people of a wide range of ages. And the lack of comprehensive diagnostic methods places a huge burden on healthcare systems and social economies. In this paper, the current status of clinical research on neuromuscular diseases is introduced, and the advantages of magnetic field measurement compared with clinical diagnostic methods are illustrated. A comprehensive description of the related technology of superconducting quantum interference devices (SQUIDs), magnetic field detection noise suppression scheme, the development trend of the sensor detection system, and the application and model establishment of the neuromuscular magnetic field is also given in this paper. The current research and development trends worldwide are compared simultaneously, and finally the conclusions and outlook are put forward. Based on the description of the existing literature and the ideas of other researchers, the next development trends and my own research ideas are presented in this paper, that is, starting from the establishment of a neuromuscular model, combining medical and industrial work, designing a sensor system that meets clinical needs, and laying the foundation for the clinical application of a bio-magnetic system. This review promotes a combination between medicine and industry, and guides researchers on considering the challenges of sensor development in terms of clinical needs. In addition, in this paper, the development trends are described, including the establishment of the model, the clinical demand for sensors, and the challenges of system development so as to give certain guidance to researchers.
Collapse
|
8
|
Electronic, optical and magnetic properties of Cu-doped ZnO, a possible system for eco-friendly and energy-efficient spintronic applications. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:98632-98646. [PMID: 36063267 DOI: 10.1007/s11356-022-22767-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 08/24/2022] [Indexed: 06/15/2023]
Abstract
Polycrystalline Zn1-xCuxO (x = 0.0, 0.02, and 0.05) samples have been prepared using the solid-state reaction procedure. The X-ray diffraction (XRD) patterns of the samples confirm that Cu ions are successfully included in the ZnO hexagonal wurtzite structure. Rietveld analysis of the XRD patterns confirms the phase purity of the synthesized samples and a slight variation in their lattice parameter upon Cu doping. The morphology study by scanning electron microscopy (SEM) depicts transfiguration with Cu doping. The existence of oxygen vacancies (Vo) in the Cu-doped samples is indicated by X-ray photoelectron spectroscopy (XPS). The magnetization measurements reveal the diamagnetic nature of pure ZnO while the Cu-doped samples depict a room-temperature ferromagnetic (RTFM) behavior. The 2% Cu-doped sample shows higher values of both the saturation magnetization and the Vo as compared to the 5% Cu-doped sample. The observed magnetization seems to show a direct relationship with the Vo. The photoluminescence (PL) and ultraviolet (UV) spectroscopic measurements were performed for their optical analysis. The presence of Vo in the Cu-doped samples is revealed by the PL findings also that is in agreement with the XPS results. The UV analysis shows that Cu doping in the ZnO influences the band gap. The observed RTFM induced by Cu doping in ZnO renders it a potential system for spintronic devices useful for energy-efficient data storage devices and energy harvesting eco-friendly applications.
Collapse
|
9
|
Limitations of the Current-Phase Relation Measurements by an Asymmetric dc- SQUID. NANO LETTERS 2023. [PMID: 37428644 DOI: 10.1021/acs.nanolett.3c01970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/12/2023]
Abstract
Exotic quantum transport phenomena established in Josephson junctions (JJs) are reflected by a nonsinusoidal current-phase relation (CPR). The solidified approach to measuring the CPR is via an asymmetric dc-SQUID with a reference JJ that has a high critical current. We probed this method by measuring CPRs of hybrid JJs based on the 3D topological insulator (TI) Bi2Te2Se with a nanobridge acting as a reference JJ. We captured both highly skewed and sinusoidal critical current oscillations within single devices which contradict the uniqueness of the CPR. This implies that the widely used method provides inaccurate CPR measurement and leads to misinterpretation. It was shown that the accuracy of the CPR measurement is mediated by the asymmetry in derivatives of the CPRs but not in critical currents, as was previously thought. Finally, we provided considerations for an accurate CPR measurement via the most commonly used reference JJs.
Collapse
|
10
|
Yttrium-Iron Garnet Magnetometer in MEG: Advance towards Multi-Channel Arrays. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094256. [PMID: 37177460 PMCID: PMC10181089 DOI: 10.3390/s23094256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/17/2023] [Accepted: 04/23/2023] [Indexed: 05/15/2023]
Abstract
Recently, a new kind of sensor applicable in magnetoencephalography (MEG) has been presented: a solid-state yttrium-iron garnet magnetometer (YIGM). The feasibility of yttrium-iron garnet magnetometers (YIGMs) was demonstrated in an alpha-rhythm registration experiment. In this paper, we propose the analysis of lead-field matrices for different possible multi-channel on-scalp sensor layouts using YIGMs with respect to information theory. Real noise levels of the new sensor were used to compute signal-to-noise ratio (SNR) and total information capacity (TiC), and compared with corresponding metrics that can be obtained with well-established MEG systems based on superconducting quantum interference devices (SQUIDs) and optically pumped magnetometers (OPMs). The results showed that due to YIGMs' proximity to the subject's scalp, they outperform SQUIDs and OPMs at their respective noise levels in terms of SNR and TiC. However, the current noise levels of YIGM sensors are unfortunately insufficient for constructing a multichannel YIG-MEG system. This simulation study provides insight into the direction for further development of YIGM sensors to create a multi-channel MEG system, namely, by decreasing the noise levels of sensors.
Collapse
|
11
|
Gamma-Ray Irradiation Induced Ultrahigh Room-Temperature Ferromagnetism in MoS 2 Sputtered Few-Layered Thin Films. ACS NANO 2023; 17:6555-6564. [PMID: 36951422 DOI: 10.1021/acsnano.2c11955] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Defect engineering is of great interest to the two-dimensional (2D) materials community. If nonmagnetic transition-metal dichalcogenides can possess room-temperature ferromagnetism (RTFM) induced by defects, then they will be ideal for application as spintronic materials and also for studying the relation between electronic and magnetic properties of quantum-confined structures. Thus, in this work, we aimed to study gamma-ray irradiation effects on MoS2, which is diamagnetic in nature. We found that gamma-ray exposure up to 9 kGy on few-layered (3.5 nm) MoS2 films induces an ultrahigh saturation magnetization of around 610 emu/cm3 at RT, whereas no significant changes were observed in the structure and magnetism of bulk MoS2 (40 nm) films even after gamma-ray irradiation. The RTFM in a few-layered gamma-ray irradiated sample is most likely due to the bound magnetic polaron created by the spin interaction of Mo 4d ions with trapped electrons present at sulfur vacancies. In addition, density functional theory (DFT) calculations suggest that the defect containing one Mo and two S vacancies is the dominant defect inducing the RTFM in MoS2. These DFT results are consistent with Raman, X-ray photoelectron spectroscopy, and ESR spectroscopy results, and they confirm the breakage of Mo and S bonds and the existence of vacancies after gamma-ray irradiation. Overall, this study suggests that the occurrence of magnetism in gamma-ray irradiated MoS2 few-layered films could be attributed to the synergistic effects of magnetic moments arising from the existence of both Mo and S vacancies as well as lattice distortion of the MoS2 structure.
Collapse
|
12
|
Validation of liver quantitative susceptibility mapping across imaging parameters at 1.5 T and 3.0 T using SQUID susceptometry as reference. Magn Reson Med 2023; 89:1418-1428. [PMID: 36408802 PMCID: PMC9892291 DOI: 10.1002/mrm.29529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 10/02/2022] [Accepted: 10/28/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE To validate QSM-based biomagnetic liver susceptometry (BLS) to measure liver iron overload at 1.5 T and 3.0 T using superconducting quantum interference devices (SQUID)-based BLS as reference. METHODS Subjects with known or suspected iron overload were recruited for QSM-BLS at 1.5 T and 3.0 T using eight different protocols. SQUID-BLS was also obtained in each subject to provide susceptibility reference. A recent QSM method based on data-adaptive regularization was used to obtain susceptibility and R 2 * $$ {\mathrm{R}}_2^{\ast } $$ maps. Measurements of susceptibility and R 2 * $$ {\mathrm{R}}_2^{\ast } $$ were obtained in the right liver lobe. Linear mixed-effects analysis was used to estimate the contribution of specific acquisition parameters to QSM-BLS. Linear regression and Bland-Altman analyses were used to assess the relationship between QSM-BLS and SQUID-BLS/ R 2 * $$ {\mathrm{R}}_2^{\ast } $$ . RESULTS Susceptibility maps showed high subjective quality for each acquisition protocol across different iron levels. High linear correlation was observed between QSM-BLS and SQUID-BLS at 1.5 T (r2 range, [0.82, 0.84]) and 3.0 T (r2 range, [0.77, 0.85]) across different acquisition protocols. QSM-BLS and R 2 * $$ {\mathrm{R}}_2^{\ast } $$ were highly correlated at both field strengths (r2 range at 1.5 T, [0.94, 0.99]; 3.0 T, [0.93, 0.99]). High correlation (r2 = 0.99) between 1.5 T and 3.0 T QSM-BLS, with narrow reproducibility coefficients (range, [0.13, 0.21] ppm) were observed for each protocol. CONCLUSION This work evaluated the feasibility and performance of liver QSM-BLS across iron levels and acquisition protocols at 1.5 T and 3.0 T. High correlation and reproducibility were observed between QSM-BLS and SQUID-BLS across protocols and field strengths. In summary, QSM-BLS may enable reliable and reproducible quantification of liver iron concentration.
Collapse
|
13
|
Highly Sensitive Tunable Magnetometer Based on Superconducting Quantum Interference Device. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23073558. [PMID: 37050617 PMCID: PMC10098524 DOI: 10.3390/s23073558] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/20/2023] [Accepted: 03/27/2023] [Indexed: 06/12/2023]
Abstract
In the present article, experimental results regarding fully integrated superconducting quantum interference devices (SQUID), including a circuit to tune and optimize the main sensor device characteristics, are reported. We show the possibility of modifying the critical current of a SQUID magnetometer in liquid helium by means of a suitable heating circuit. This allows us to improve the characteristics of the SQUID sensor and in particular to optimize the voltage-magnetic flux characteristic and the relative transfer factor (responsivity) and consequently to also improve the flux and magnetic field noise. It is also possible to reset the SQUID sensor in case of entrapment of magnetic flux, avoiding taking it out of the helium bath. These results are very useful in view of most SQUID applications such as those requiring large multichannel systems in which it is desirable to optimize and eventually reset the magnetic sensors in a simple and effective way.
Collapse
|
14
|
A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs-First Applications in Healthy Volunteers. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23052801. [PMID: 36905007 PMCID: PMC10006929 DOI: 10.3390/s23052801] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 02/16/2023] [Accepted: 02/24/2023] [Indexed: 06/06/2023]
Abstract
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.
Collapse
|
15
|
Applying the FMR Technique to Analyzing the Influence of Nitriding on the Magnetic Properties of Steel. MATERIALS 2022; 15:ma15124080. [PMID: 35744139 PMCID: PMC9227926 DOI: 10.3390/ma15124080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/03/2022] [Accepted: 06/06/2022] [Indexed: 12/10/2022]
Abstract
This paper presents the relationship between the chemical composition and size of steel balls, the parameters of the nitriding process, and their magnetic properties, defined in this study by ferromagnetic resonance (FMR) and SQUID. Balls made from AISI 1010 and AISI 52100 steels, with diameters of 2.5 and 3 mm, respectively, were investigated. On samples made of AISI 1010 and AISI 52100 steel, single-phase layers of iron nitrides γ’ with a thickness of gmp = 50 and 37 μm, respectively, were produced. Then, the samples were annealed at a temperature of 520 °C for 4 h in an inert atmosphere (N2/Ar) at a pressure of 200 Pa. After the nitriding processes, steel balls were subjected to standard physical metallurgy and X-ray examinations. During annealing of nitrided layers with a two-phase layer of iron nitrides, at first, the transformation of the ε phase into the γ’ phase with the release of nitrogen into the atmosphere takes place. The FMR signals did not originate from isolated ions, but from more magnetically complex systems, e.g., Fe–Fe pairs or iron clusters, while the observed FMR line position is normally even lower and occurs for a magnetic induction below 200 mT. The fact that the magnetic centers did not contain mainly isolated Fe ions, additionally confirmed the abnormal increase in resonance signal intensity as a function of temperature, which is a behavior inconsistent with the Curie–Weiss law. The results obtained from measurements by the SQUID method, recording variations in magnetization as a function of temperature, confirm the untypical reinforcement of the magnetic conditions of the samples with the increase in temperature. For the samples tested, the magnetization was relatively weaker when the tests were conducted in a stronger magnetic field.
Collapse
|
16
|
Performance Analysis of Optically Pumped 4He Magnetometers vs. Conventional SQUIDs: From Adult to Infant Head Models. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22083093. [PMID: 35459077 PMCID: PMC9024855 DOI: 10.3390/s22083093] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 03/30/2022] [Accepted: 04/08/2022] [Indexed: 05/27/2023]
Abstract
Optically pumped magnetometers (OPMs) are new, room-temperature alternatives to superconducting quantum interference devices (SQUIDs) for measuring the brain's magnetic fields. The most used OPM in MagnetoEncephaloGraphy (MEG) are based on alkali atoms operating in the spin-exchange relaxation-free (SERF) regime. These sensors do not require cooling but have to be heated. Another kind of OPM, based on the parametric resonance of 4He atoms are operated at room temperature, suppressing the heat dissipation issue. They also have an advantageous bandwidth and dynamic range more suitable for MEG recordings. We quantitatively assessed the improvement (relative to a SQUID magnetometers array) in recording the magnetic field with a wearable 4He OPM-MEG system through data simulations. The OPM array and magnetoencephalography forward models were based on anatomical MRI data from an adult, a nine-year-old child, and 10 infants aged between one month and two years. Our simulations showed that a 4He OPMs array offers markedly better spatial specificity than a SQUID magnetometers array in various key performance areas (e.g., signal power, information content, and spatial resolution). Our results are also discussed regarding previous simulation results obtained for alkali OPM.
Collapse
|
17
|
Superconducting Materials and Devices Grown by Focused Ion and Electron Beam Induced Deposition. NANOMATERIALS 2022; 12:nano12081367. [PMID: 35458074 PMCID: PMC9029853 DOI: 10.3390/nano12081367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/11/2022] [Accepted: 04/13/2022] [Indexed: 01/27/2023]
Abstract
Since its discovery in 1911, superconductivity has represented an equally inciting and fascinating field of study in several areas of physics and materials science, ranging from its most fundamental theoretical understanding, to its practical application in different areas of engineering. The fabrication of superconducting materials can be downsized to the nanoscale by means of Focused Ion/Electron Beam Induced Deposition: nanopatterning techniques that make use of a focused beam of ions or electrons to decompose a gaseous precursor in a single step. Overcoming the need to use a resist, these approaches allow for targeted, highly-flexible nanopatterning of nanostructures with lateral resolution in the range of 10 nm to 30 nm. In this review, the fundamentals of these nanofabrication techniques are presented, followed by a literature revision on the published work that makes use of them to grow superconducting materials, the most remarkable of which are based on tungsten, niobium, molybdenum, carbon, and lead. Several examples of the application of these materials to functional devices are presented, related to the superconducting proximity effect, vortex dynamics, electric-field effect, and to the nanofabrication of Josephson junctions and nanoSQUIDs. Owing to the patterning flexibility they offer, both of these techniques represent a powerful and convenient approach towards both fundamental and applied research in superconductivity.
Collapse
|
18
|
Synthesis and Characterization of [Fe(Htrz) 2(trz)](BF 4)] Nanocubes. Molecules 2022; 27:1213. [PMID: 35209000 PMCID: PMC8874602 DOI: 10.3390/molecules27041213] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 02/03/2022] [Accepted: 02/05/2022] [Indexed: 11/16/2022] Open
Abstract
Compounds that exhibit spin-crossover (SCO) type behavior have been extensively investigated due to their ability to act as molecular switches. Depending on the coordinating ligand, in this case 1H-1,2,4-triazole, and the crystallite size of the SCO compound produced, the energy requirement for the spin state transition can vary. Here, SCO [Fe(Htrz)2(trz)](BF4)] nanoparticles were synthesized using modified reverse micelle methods. Reaction conditions and reagent ratios are strictly controlled to produce nanocubes of 40-50 nm in size. Decreases in energy requirements are seen in both thermal and magnetic transitions for the smaller sized crystallites, where, compared to bulk materials, a decrease of as much as 20 °C can be seen in low to high spin state transitions.
Collapse
|
19
|
In Situ Compensation Method for Precise Integral SQUID Magnetometry of Miniscule Biological, Chemical, and Powder Specimens Requiring the Use of Capsules. MATERIALS 2022; 15:ma15020495. [PMID: 35057212 PMCID: PMC8780521 DOI: 10.3390/ma15020495] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 01/05/2022] [Accepted: 01/06/2022] [Indexed: 01/25/2023]
Abstract
Steadily growing interest in magnetic characterization of organic compounds for therapeutic purposes or of other irregularly shaped specimens calls for refinements of experimental methodology to satisfy experimental challenges. Encapsulation in capsules remains the method of choice, but its applicability in precise magnetometry is limited. This is particularly true for minute specimens in the single milligram range as they are outweighed by the capsules and are subject to large alignment errors. We present here a completely new experimental methodology that permits 30-fold in situ reduction of the signal of capsules by substantially restoring the symmetry of the sample holder that is otherwise broken by the presence of the capsule. In practical terms it means that the standard 30 mg capsule is seen by the magnetometer as approximately a 1 mg object, effectively opening the window for precise magnetometry of single milligram specimens. The method is shown to work down to 1.8 K and in the whole range of the magnetic fields. The method is demonstrated and validated using the reciprocal space option of MPMS-SQUID magnetometers; however, it can be easily incorporated in any magnetometer that can accommodate straw sample holders (i.e., the VSM-SQUID). Importantly, the improved sensitivity is accomplished relying only on the standard accessories and data reduction method provided by the SQUID manufacturer, eliminating the need for elaborate raw data manipulations.
Collapse
|
20
|
Determining the rotational orientation of directional deep brain stimulation electrodes using magnetoencephalography. J Neural Eng 2021; 18. [PMID: 34598173 DOI: 10.1088/1741-2552/ac2c4d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 10/01/2021] [Indexed: 11/11/2022]
Abstract
Objective.The aim of the present study was to evaluate the effect of different electrode configurations on the accuracy of determining the rotational orientation of the directional deep brain stimulation (DBS) electrode with our previously published magnetoencephalography (MEG)-based method.Approach.A directional DBS electrode, along with its implantable pulse generator, was integrated into a head phantom and placed within the MEG sensor array. Predefined bipolar electrode configurations, based on activation of different directional and omnidirectional contacts of the electrode, were set to generate a defined magnetic field during stimulation. This magnetic field was then measured with MEG. Finite element modeling and model fitting approach were used to calculate electrode orientation.Main results.The accuracy of electrode orientation detection depended on the electrode configuration: the vertical configuration (activation of two directional contacts arranged one above the other) achieved an average accuracy of only about 41 ∘. The diagonal configuration (activation of the electrode tip and a single directional contact at the next higher level of the electrode) achieved an accuracy of 13∘, while the horizontal electrode configuration (activation of two adjacent directional contacts at the same electrode level) achieved the best accuracy of 6∘. The accuracy of orientation detection of the DBS electrode depends on the change in spatial distribution of the magnetic field with the rotation of the electrode along its own axis. In the vertical configuration, rotation of the electrode has a small effect on the magnetic field distribution, while in the diagonal or horizontal configuration, electrode rotation has a significant effect on the magnetic field distribution.Significance.Our work suggests that in order to determine rotational orientation of a DBS electrode using MEG, horizontal configuration should be used as it provides the most accurate results compared to other possible configurations.
Collapse
|
21
|
Trigonal Prismatic Coordination of Discrete Rare Earth Ions, Enforced by the Polyoxotungstate [P 4 W 27 O 99 (H 2 O)] 16. Chemistry 2021; 27:13376-13383. [PMID: 34259354 PMCID: PMC8518533 DOI: 10.1002/chem.202101474] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Indexed: 12/03/2022]
Abstract
A family of solution‐stable polyanions [Na⊂{LnIII(H2O)}{WVIO(H2O)}PV4WVI26O98]12− (Ln=Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu and Y) represent the first examples of polyoxometalates comprising a single lanthanide(III) or yttrium(III) ion in a rare trigonal prismatic O6 environment. Their synthesis exploits the reactivity of the organophosphonate‐functionalized precursor [P4W24O92(C6H5PVO)2]16− with heterometal ions and yields hydrated potassium or mixed lithium/potassium salts of composition KxLnyH12–x–y[Na⊂{Ln(H2O)}{WO(H2O)}P4W26O98]⋅nH2O⋅mLiCl (x=8.5–11; y=0–2; n=24–34; m=0–1.5). The Dy, Ho, Er and Yb derivatives are characterized by slow magnetization relaxation.
Collapse
|
22
|
Investigation of Magnetoelectric Sensor Requirements for Deep Brain Stimulation Electrode Localization and Rotational Orientation Detection. SENSORS 2021; 21:s21072527. [PMID: 33916581 PMCID: PMC8038485 DOI: 10.3390/s21072527] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 03/28/2021] [Accepted: 03/30/2021] [Indexed: 11/17/2022]
Abstract
Correct position and orientation of a directional deep brain stimulation (DBS) electrode in the patient’s brain must be known to fully exploit its benefit in guiding stimulation programming. Magnetoelectric (ME) sensors can play a critical role here. The aim of this study was to determine the minimum required limit of detection (LOD) of a ME sensor that can be used for this application by measuring the magnetic field induced by DBS. For this experiment, a commercial DBS system was integrated into a head phantom and placed inside of a state-of-the-art Superconducting Quantum Interference Device (SQUID)-based magnetoencephalography system. Measurements were performed and analyzed with digital signal processing. Investigations have shown that the minimum required detection limit depends on various factors such as: measurement distance to electrode, bandwidth of magnetic sensor, stimulation amplitude, stimulation pulse width, and measurement duration. For a sensor that detects only a single DBS frequency (stimulation frequency or its harmonics), a LOD of at least 0.04 pT/Hz0.5 is required for 3 mA stimulation amplitude and 60 μs pulse width. This LOD value increases by an order of magnitude to 0.4 pT/Hz0.5 for a 1 kHz, and by approximately two orders to 3 pT/Hz0.5 for a 10 kHz sensor bandwidth. By averaging, the LOD can be reduced by at least another 2 orders of magnitude with a measurement duration of a few minutes.
Collapse
|
23
|
Fabrication Process for Deep Submicron SQUID Circuits with Three Independent Niobium Layers. MICROMACHINES 2021; 12:mi12040350. [PMID: 33805232 PMCID: PMC8064365 DOI: 10.3390/mi12040350] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/17/2021] [Accepted: 03/17/2021] [Indexed: 11/17/2022]
Abstract
We present a fabrication technology for nanoscale superconducting quantum interference devices (SQUIDs) with overdamped superconductor-normal metal-superconductor (SNS) trilayer Nb/HfTi/Nb Josephson junctions. A combination of electron-beam lithography with chemical-mechanical polishing and magnetron sputtering on thermally oxidized Si wafers is used to produce direct current SQUIDs with 100-nm-lateral dimensions for Nb lines and junctions. We extended the process from originally two to three independent Nb layers. This extension offers the possibility to realize superconducting vias to all Nb layers without the HfTi barrier, and hence to increase the density and complexity of circuit structures. We present results on the yield of this process and measurements of SQUID characteristics.
Collapse
|
24
|
Tuning the Magnetic Properties of Two-Dimensional MXenes by Chemical Etching. MATERIALS (BASEL, SWITZERLAND) 2021; 14:694. [PMID: 33540805 PMCID: PMC7867348 DOI: 10.3390/ma14030694] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 01/28/2021] [Accepted: 01/30/2021] [Indexed: 11/17/2022]
Abstract
Two-dimensional materials based on transition metal carbides have been intensively studied due to their unique properties including metallic conductivity, hydrophilicity and structural diversity and have shown a great potential in several applications, for example, energy storage, sensing and optoelectronics. While MXenes based on magnetic transition elements show interesting magnetic properties, not much is known about the magnetic properties of titanium-based MXenes. Here, we measured the magnetic properties of Ti3C2Tx MXenes synthesized by different chemical etching conditions such as etching temperature and time. Our magnetic measurements were performed in a superconducting quantum interference device (SQUID) vibrating sample. These data suggest that there is a paramagnetic-antiferromagnetic (PM-AFM) phase transition and the transition temperature depends on the synthesis procedure of MXenes. Our observation indicates that the magnetic properties of these MXenes can be tuned by the extent of chemical etching, which can be beneficial for the design of MXenes-based spintronic devices.
Collapse
|
25
|
DBS electrode localization and rotational orientation detection using SQUID-based magnetoencephalography. J Neural Eng 2021; 18. [PMID: 33503598 DOI: 10.1088/1741-2552/abe099] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 01/27/2021] [Indexed: 11/12/2022]
Abstract
The aim of the present study was to investigate the accuracy of localization and rotational orientation detection of a directional deep brain stimulation (DBS) electrode using a state-of-the-art magnetoencephalography (MEG) scanner. A directional DBS electrode along with its stimulator was integrated into a head phantom and placed inside the MEG sensor array. The electrode was comprised of six directional and two omnidirectional contacts. Measurements were performed while stimulating with different contacts and parameters in the phantom. Finite element modeling and fitting approach were used to compute electrode position and orientation. The electrode was localized with a mean accuracy of 2.2 mm while orientation was determined with a mean accuracy of 11°. The limitation in detection accuracy was due to the lower measurement precision of the MEG system. Considering an ideal measurement condition, these values represent the lower bound of accuracy that can be achieved in patients. However, a future magnetic measuring system with higher precision will potentially detect location and orientation of a DBS electrode with an even increased accuracy.
Collapse
|
26
|
Flux Tunable Superconducting Quantum Circuit Based on Weyl Semimetal MoTe 2. NANO LETTERS 2020; 20:8469-8475. [PMID: 33174417 DOI: 10.1021/acs.nanolett.0c02267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Weyl semimetals have drawn considerable attention for their exotic topological properties in many research fields. When in combination with s-wave superconductors, the supercurrent can be carried by their topological surface channels, forming junctions mimicking the behavior of Majorana bound states. Here, we present a transmon-like superconducting quantum intereference device (SQUID) consisting of lateral junctions made of Weyl semimetal Td-MoTe2 and superconducting leads of niobium nitride (NbN). The SQUID is coupled to a readout cavity made of molybdenum rhenium (MoRe), whose response at high power reveals the existence of the constituting Josephson junctions (JJs). The loop geometry of the circuit allows the resonant frequency of the readout cavity to be tuned by the magnetic flux. We demonstrate a JJ made of MoTe2 and a flux-tunable transmon-like circuit based on Weyl semimetals. Our study provides a platform to utilize topological materials in SQUID-based quantum circuits for potential applications in quantum information processing.
Collapse
|
27
|
Magnetism, Conductivity and Spin-Spin Interactions in Layered Hybrid Structure of Anionic Radicals [Ni(dmit) 2] Alternated by Iron(III) Spin-Crossover Complex [Fe(III)(3-OMe-Sal 2trien)] and Ferric Moiety Precursors. MOLECULES (BASEL, SWITZERLAND) 2020; 25:molecules25214922. [PMID: 33114397 PMCID: PMC7663777 DOI: 10.3390/molecules25214922] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 10/19/2020] [Accepted: 10/22/2020] [Indexed: 11/19/2022]
Abstract
In this study, crystals of the hybrid layered structure, combined with Fe(III) Spin-Crossover (SCO) complexes with metal-dithiolate anionic radicals, and the precursors with nitrate and iodine counterions, are obtained and characterized. [Fe(III)(3-OMe-Sal2trien)][Ni(dmit)2] (1), [Fe(III)(3-OMe-Sal2trien)]NO3·H2O (2), [Fe(III)(3-OMe-Sal2trien)]I (3) (3-OMe-Sal2trien = hexadentate N4O2 Schiff base is the product of the condensation of triethylenetetramine with 3-methoxysalicylaldehyde; H2dmit = 2-thioxo-1,3-dithiole-4,5-dithiol). Bulk SCO transition was not achieved in the range 2.0–350 K for all three compounds. Alternatively, the hybrid system (1) exhibited irreversible segregation into the spatial fractions of Low-Spin (LS) and High-Spin (HS) phases of the ferric moiety, induced by thermal cycling. Fractioning was studied using both SQUID and EPR methods. Magnetic properties of the LS and HS phases were analyzed in the framework of cooperative interactions with anionic sublattice: Anion radical layers Ni(dmit)2 (1), and H-bonded chains with NO3 and I (2,3). LS phase of (1) exhibited unusual quasi-two-dimensional conductivity related to the Arrhenius mechanism in the anion radical layers, ρ||c = 2 × 105 Ohm·cm and ρ⊥c = 7 × 102 Ohm·cm at 293 K. Ground spin state of the insulating HS phase was distinctive by ferromagnetically coupled spin pairs of HS Fe3+, S = 5/2, and metal-dithiolate radicals, S = 1/2.
Collapse
|
28
|
Abstract
2D systems that host 1D helical states are advantageous from the perspective of scalable topological quantum computation when coupled to a superconductor. Graphene is particularly promising for its high electronic quality, its versatility in van der Waals heterostructures, and its electron- and hole-like degenerate 0th Landau level. Here we study a compact double-layer graphene SQUID (superconducting quantum interference device), where the superconducting loop is reduced to the superconducting contacts connecting two parallel graphene Josephson junctions. Despite the small size of the SQUID, it is fully tunable by the independent gate control of the chemical potentials in both layers. Furthermore, both Josephson junctions show a skewed current-phase relationship, indicating the presence of superconducting modes with high transparency. In the quantum Hall regime, we measure a well-defined conductance plateau of 2e2/h indicative of counter-propagating edge channels in the two layers.
Collapse
|
29
|
Sensitive SQUID Bio-Magnetometry for Determination and Differentiation of Biogenic Iron and Iron Oxide Nanoparticles in the Biological Samples. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1993. [PMID: 33050346 PMCID: PMC7601190 DOI: 10.3390/nano10101993] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 09/24/2020] [Accepted: 10/02/2020] [Indexed: 12/22/2022]
Abstract
This study aimed to develop the method for determination of the ultra-small superparamagnetic iron oxide nanoparticle (USPION)-originated iron (UOI) in the tissues of rats on the basis of the magnetic characteristics (MC) in the liver, left heart ventricle (LHV), kidneys, aorta and blood of Wistar-Kyoto (WKY). Rats were treated intravenously by USPIONs dispersed in saline (transmission electron microscope (TEM) mean size ~30 nm, hydrodynamic size ~51 nm, nominal iron content 1 mg Fe/mL) at the low iron dose of 1 mg/kg. MC in the form of the mass magnetisation (M) versus the magnetic field (H) curves and temperature dependences of M (determined using the SQUID magnetometer), histochemical determination of iron (by Perl's method) and USPION-induced superoxide production (by lucigenin-enhanced chemiluminescence) were investigated 100 min post-infusion. USPIONs significantly elevated superoxide production in the liver, LHV, kidney and aorta vs. the control group. Histochemical staining confirmed the presence of iron in all solid biological samples, however, this method was not suitable to unequivocally confirm the presence of UOI. We improved the SQUID magnetometric method and sample preparation to allow the determination of UOI by measurements of the MC of the tissues at 300 K in solid and liquid samples. The presence of the UOI was confirmed in all the tissues investigated in USPIONs-treated rats. The greatest levels were found in blood and lower amounts in the aorta, liver, LHV and kidneys. In conclusion, we have improved SQUID-magnetometric method to make it suitable for detection of low amounts of UOI in blood and tissues of rats.
Collapse
|
30
|
Abstract
BACKGROUND Endovascular therapy with liquid embolic agents (LEAs) is the gold standard for the treatment of cerebral dural arteriovenous fistulas (cDAVFs). The aim of the study is to retrospectively evaluate effectiveness, safety, and midterm follow-up results of endovascular treatment of cDAVFs using SQUID 12. METHODS Between June 2017 and January 2020 the authors retrospectively reviewed clinical, demographic and embolization data of 19 consecutive patients with cDAVF who underwent embolization using SQUID 12. The number of arteries catheterized for each procedure, the total amount of embolic agent, the occlusion rate, the injection time, any technical and/or clinical complications were recorded. Mid-term follow-up with DSA was reviewed. RESULTS 20 procedures were performed in 19 patients. A transarterial approach was accomplished in 19 procedure; a combined transvenous-transarterial approach was realized in 1 treatment. The average time of injection was 33 minutes (2-82 minutes), and the average amount of SQUID 12 was 2.8 mL (0.5-6 mL). Complete angiographic cure at the end of the procedure was achieved in 17 patients. No major periprocedural adverse events were recorded. Mid-term follow-up was achieved in 15 out of 19 patients and confirmed complete occlusion of the cDAVFs in 13/15 patients (87%); in 2 of the initially cured patients a small relapse was detected. CONCLUSIONS The treatment of the cDAVFs using SQUID 12 was effective and safe. The lower viscosity seems to allow an easier penetration of the agent with a high rate of complete occlusion of the cDAVFs.
Collapse
|
31
|
Magnetism of Kesterite Cu 2ZnSnS 4 Semiconductor Nanopowders Prepared by Mechanochemically Assisted Synthesis Method. MATERIALS 2020; 13:ma13163487. [PMID: 32784643 PMCID: PMC7476044 DOI: 10.3390/ma13163487] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 07/31/2020] [Accepted: 08/03/2020] [Indexed: 11/25/2022]
Abstract
High energy ball milling is used to make first the quaternary sulfide Cu2ZnSnS4 raw nanopowders from two different precursor systems. The mechanochemical reactions in this step afford cubic pre-kesterite with defunct semiconducting properties and showing no solid-state 65Cu and 119Sn MAS NMR spectra. In the second step, each of the milled raw materials is annealed at 500 and 550 °C under argon to result in tetragonal kesterite nanopowders with the anticipated UV-Vis-determined energy band gap and qualitatively correct NMR characteristics. The magnetic properties of all materials are measured with SQUID magnetometer and confirm the pre-kesterite samples to show typical paramagnetism with a weak ferromagnetic component whereas all the kesterite samples to exhibit only paramagnetism of relatively decreased magnitude. Upon conditioning in ambient air for 3 months, a pronounced increase of paramagnetism is observed in all materials. Correlations between the magnetic and spectroscopic properties of the nanopowders including impact of oxidation are discussed. The magnetic measurements coupled with NMR spectroscopy appear to be indispensable for comprehensive kesterite evaluation.
Collapse
|
32
|
Magnetic Behaviour of Mn 12-Stearate Single-Molecule Magnets Immobilized on the Surface of 300 nm Spherical Silica Nanoparticles. MATERIALS 2020; 13:ma13112624. [PMID: 32526883 PMCID: PMC7321606 DOI: 10.3390/ma13112624] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 05/21/2020] [Accepted: 06/03/2020] [Indexed: 11/16/2022]
Abstract
The magnetic behaviour of Mn12-stearate single-molecule magnets (SMMs) ([Mn12O12(CH3(CH2)16CO2)16]·2CH3COOH·4H2O) on the surface of 300 nm spherical silica nanoparticles were investigated. The SMMs were bonded at the silica surface with the assumed number of anchoring points, which influenced on their degree of freedom and distribution. In order to check the properties of Mn12-stearate molecules separated on the silica surface, and check their interactions, the samples containing four different concentration of spacers per single anchoring unit and variously bonded Mn12-stearate particles were prepared. The materials have been examined using Raman spectroscopy, transmission electron microscopy, and SQUID magnetometry. The results of magnetic measurements showed a correlation between the way of single-molecule magnets immobilization onto the silica spheres and the magnetic properties of the obtained hybrid materials.
Collapse
|
33
|
Analytical Measurements to Elucidate Structural Behavior of 2,5-Dimethoxy-1,4-benzoquinone During Charge and Discharge. CHEMSUSCHEM 2020; 13:2354-2363. [PMID: 32220113 PMCID: PMC7317396 DOI: 10.1002/cssc.201903575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 03/23/2020] [Indexed: 06/10/2023]
Abstract
Organic compounds as electrode materials can contribute to sustainability because they are nontoxic and environmentally abundant. The working mechanism during charge-discharge for reported organic compounds as electrode materials is yet to be completely understood. In this study, the structural behavior of 2,5-dimethoxy-1,4-benzoquinone (DMBQ) during charge-discharge is investigated by using NMR spectroscopy, energy-dispersive X-ray spectroscopy, magnetic measurements, operando Raman spectroscopy, and operando X-ray diffraction. For both lithium and sodium systems, DMBQ works as a cathode accompanied with the insertion and deinsertion of Li and Na ions during charge-discharge processes. The DMBQ sample is found to be in two-phase coexistence state at the higher voltage plateau, and the radical monoanion and dianion phases have no long-distance ordering. These structures reversibly change into the original neutral phase with long-distance ordering. These techniques can show the charge-discharge mechanism and the factors that determine the deterioration of organic batteries, thus guiding the design of future high-performance organic batteries.
Collapse
|
34
|
Evaluation of neural activity by magnetospinography with 3D sensors. Clin Neurophysiol 2020; 131:1252-1266. [PMID: 32299009 DOI: 10.1016/j.clinph.2020.02.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 01/10/2020] [Accepted: 02/15/2020] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Magnetospinography (MSG) has been developed for clinical application and is expected to be a novel neurophysiological examination. Here, we used an MSG system with sensors positioned in three orthogonal directions to record lumbar canal evoked magnetic fields (LCEFs) in response to peripheral nerve stimulation and to evaluate methods for localizing spinal cord lesions. METHODS LCEFs from the lumbar area of seven rabbits were recorded by the MSG system in response to electrical stimulation of a sciatic nerve. LCEFs and lumbar canal evoked potentials (LCEPs) were measured before and after spinal cord compression induced by a balloon catheter. The lesion positions were estimated using LCEPs and computationally reconstructed currents corresponding to the depolarization site. RESULTS LCEFs were recorded in all rabbits and neural activity in the lumbar spinal cord could be visualized in the form of a magnetic contour map and reconstructed current map. The position of the spinal cord lesion could be estimated by the LCEPs and reconstructed currents at the depolarization site. CONCLUSIONS MSG can visualize neural activity in the spinal cord and localize the lesion site. SIGNIFICANCE MSG enables noninvasive assessment of neural activity in the spinal canal using currents at depolarization sites reconstructed from LCEFs.
Collapse
|
35
|
Influence of Resonances on the Noise Performance of SQUID Susceptometers. SENSORS 2019; 20:s20010204. [PMID: 31905901 PMCID: PMC6983001 DOI: 10.3390/s20010204] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 12/23/2019] [Accepted: 12/27/2019] [Indexed: 11/28/2022]
Abstract
Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique requires a thorough understanding of the current, voltage, and flux (IVΦ) characteristics of scanning SQUID susceptometers. These sensors often have striking anomalies in their current–voltage characteristics, which we believe to be due to electromagnetic resonances. The effect of these resonances on the performance of these SQUIDs is unknown. To explore the origin and impact of the resonances, we develop a model that qualitatively reproduces the experimentally-determined IVΦ characteristics of our scanning SQUID susceptometers. We use this model to calculate the noise characteristics of SQUIDs of different designs. We find that the calculated ultimate flux noise is better in susceptometers with damping resistors that diminish the resonances than in susceptometers without damping resistors. Such calculations will enable the optimization of the signal-to-noise characteristics of scanning SQUID susceptometers.
Collapse
|
36
|
Abstract
Stable meta- and para-phenylene bridged porphyrin meso-oxy radical dimers and their NiII and ZnII complexes were synthesized. All the dimers exhibited optical and electrochemical properties similar to the corresponding porphyrin meso-oxy radical monomers, indicating small electronic interaction between the two spins. Intramolecular spin-spin interaction through the π-spacer was determined to be J/kB =-15.9 K for m-phenylene bridged ZnII porphyrin dimer. The observed weak antiferromagnetic interaction has been attributed to less effective conjugation between the porphyrin radical and linking π-spacer due to large dihedral angle. In the case of ZnII complexes, both para- and meta-phenylene bridged dimers formed 1D-chain in solutions and in the solid states through Zn-O coordination.
Collapse
|
37
|
Multiple Quantum Coherences Hyperpolarized at Ultra-Low Fields. Chemphyschem 2019; 20:2823-2829. [PMID: 31536665 PMCID: PMC6900040 DOI: 10.1002/cphc.201900757] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 09/17/2019] [Indexed: 11/26/2022]
Abstract
The development of hyperpolarization technologies enabled several yet exotic NMR applications at low and ultra-low fields (ULF), where without hyperpolarization even the detection of a signal from analytes is a challenge. Herein, we present a method for the simultaneous excitation and observation of homo- and heteronuclear multiple quantum coherences (from zero up to the third-order), which give an additional degree of freedom for ULF NMR experiments, where the chemical shift variation is negligible. The approach is based on heteronuclear correlated spectroscopy (COSY); its combination with a phase-cycling scheme allows the selective observation of multiple quantum coherences of different orders. The nonequilibrium spin state and multiple spin orders are generated by signal amplification by reversible exchange (SABRE) and detected at ULF with a superconducting quantum interference device (SQUID)-based NMR system.
Collapse
|
38
|
Abstract
Gate-tunable Josephson junctions (JJs) are the backbone of superconducting classical and quantum computation. Typically, these systems exploit low-charge-concentration materials and present technological difficulties limiting their scalability. Surprisingly, electric field modulation of a supercurrent in metallic wires and JJs has been recently demonstrated. Here, we report the realization of titanium-based monolithic interferometers which allow tuning both JJs independently via voltage bias applied to capacitively coupled electrodes. Our experiments demonstrate full control of the amplitude of the switching current (Is) and of the superconducting phase across the single JJ in a wide range of temperatures. Astoundingly, by gate-biasing a single junction, the maximum achievable total Is is suppressed down to values much lower than the critical current of a single JJ. A theoretical model including gate-induced phase fluctuations on a single junction accounts for our experimental findings. This class of quantum interferometers could represent a breakthrough for several applications such as digital electronics, quantum computing, sensitive magnetometry, and single-photon detection.
Collapse
|
39
|
Investigation of Arrays of Two-dimensional High- T C SQUIDs for Optimization of Electrical Properties. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY : A PUBLICATION OF THE IEEE SUPERCONDUCTIVITY COMMITTEE 2019; 29:10.1109/TASC.2019.2904481. [PMID: 32042239 PMCID: PMC7010310 DOI: 10.1109/tasc.2019.2904481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In this work, we investigate two-dimensional arrays of High-T C superconducting quantum interference devices (SQUIDs) for optimization of their electrical transport characteristics. Specifically, we look at devices with different electrode configurations in between the series segments to gain insight into how the array spacing, in the direction of the bias current, affects the voltage magnetic field characteristics. Our results suggest that for spacing dimensions greater than the penetration depth interactions are minimal. Furthermore, comparisons of voltage field characteristics reveal higher modulation voltages and narrower peaks with as the numbers of SQUIDs in the parallel direction increases from 1 to 6. For larger numbers of SQUIDs in parallel greater than 6 little change is observed. These results suggest a pathway to SQUID array scaling for very large numbers of SQUIDs within in a small area.
Collapse
|
40
|
[Discussion on Technical Evaluation of Magnetocardiography]. ZHONGGUO YI LIAO QI XIE ZA ZHI = CHINESE JOURNAL OF MEDICAL INSTRUMENTATION 2019; 43:294-296. [PMID: 31460725 DOI: 10.3969/j.issn.1671-7104.2019.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
There is no corresponding product standard and industry standard for the search and development of magnetocardiograph at home and abroad. In this paper, based on the working principle and clinical application function of magnetocardiograph, and on the basis of relevant regulations and normative documents of medical device registration, some thoughts and concerns about the technical review of this kind of product are put forward.
Collapse
|
41
|
Grooved Dayem Nanobridges as Building Blocks of High-Performance YBa 2Cu 3O 7-δ SQUID Magnetometers. NANO LETTERS 2019; 19:1902-1907. [PMID: 30746946 DOI: 10.1021/acs.nanolett.8b04991] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present noise measurements performed on a YBa2Cu3O7-δ nanoscale weak-link-based magnetometer consisting of a superconducting quantum interference device (SQUID) galvanically coupled to a 3.5 × 3.5 mm2 pick-up loop, reaching white flux noise levels and magnetic noise levels as low as [Formula: see text] and 100 fT/[Formula: see text] at T = 77 K, respectively. The low noise is achieved by introducing grooved Dayem bridges (GDBs), a new concept of a weak link. A fabrication technique has been developed for the realization of nanoscale grooved bridges, which substitutes standard Dayem bridge weak links. The introduction of these novel key blocks reduces the parasitic inductance of the weak links and increases the differential resistance of the SQUIDs. This greatly improves the device performance, thus resulting in a reduction of the white noise.
Collapse
|
42
|
Magnetoencephalography for localizing and characterizing the epileptic focus. HANDBOOK OF CLINICAL NEUROLOGY 2019; 160:203-214. [PMID: 31277848 DOI: 10.1016/b978-0-444-64032-1.00013-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Magnetoencephalography (MEG) is the noninvasive measurement of the miniscule magnetic fields produced by electrical currents flowing in the brain-the same neuroelectric activity that produces the EEG. MEG is one of several diagnostic tests employed in the evaluation of patients with epilepsy, but without the need to expose the patient to any potentially harmful agents. MEG is especially important in those being considered for epilepsy surgery, in whom accurate localization of the epileptic focus is paramount. While other modalities infer brain function indirectly by measuring changes in blood flow, metabolism, oxygenation, etc., MEG, as well as EEG, measures neuronal and synaptic function directly and, like EEG, MEG enjoys submillisecond temporal resolution. The measurement of magnetic fields provides information not only about the amplitude of the current but also its orientation. MEG picks up the magnetic field from neuromagnetometers surrounding the head in a helmet-shaped array of sensors. Clinical whole-head systems currently have 200-300 magnetic sensors, thereby offering very high resolution. The magnetic signals are not distorted by anatomy, because magnetic susceptibility is the same for all tissues, including the skull. Hence, MEG allows for a more accurate measurement and localization of brain activities than does EEG. Because one of its primary strengths is the ability to precisely localize electromagnetic activity within brain areas, MEG results are always coregistered to the patient's MRI. When combined in this way with structural imaging, it has been called magnetic source imaging (MSI), but MEG is properly understood as a clinical neurophysiologic diagnostic test. Signal processing and clinical interpretation in magnetoencephalography require sophisticated noise reduction and computerized mathematical modeling. Technological advances in these areas have brought MEG to the point where it is now part of routine clinical practice. MEG has become an indispensable part of the armamentarium at epilepsy centers where MEG laboratories are located, especially when patients are MRI-negative or where results of other structural and functional tests are not entirely concordant.
Collapse
|
43
|
Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume. Neuroimage 2018; 186:185-191. [PMID: 30394329 DOI: 10.1016/j.neuroimage.2018.10.071] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 10/24/2018] [Accepted: 10/26/2018] [Indexed: 11/23/2022] Open
Abstract
We investigate the feasibility of performing functional MRI (fMRI) at ultralow field (ULF) with a Superconducting QUantum Interference Device (SQUID), as used for detecting magnetoencephalography (MEG) signals from the human head. While there is negligible magnetic susceptibility variation to produce blood oxygenation level-dependent (BOLD) contrast at ULF, changes in cerebral blood volume (CBV) may be a sensitive mechanism for fMRI given the five-fold spread in spin-lattice relaxation time (T1) values across the constituents of the human brain. We undertook simulations of functional signal strength for a simplified brain model involving activation of a primary cortical region in a manner consistent with a blocked task experiment. Our simulations involve measured values of T1 at ULF and experimental parameters for the performance of an upgraded ULFMRI scanner. Under ideal experimental conditions we predict a functional signal-to-noise ratio of between 3.1 and 7.1 for an imaging time of 30 min, or between 1.5 and 3.5 for a blocked task experiment lasting 7.5 min. Our simulations suggest it may be feasible to perform fMRI using a ULFMRI system designed to perform MRI and MEG in situ.
Collapse
|
44
|
Measuring Number of Free Radicals and Evaluating the Purity of Di(phenyl)-(2,4,6-trinitrophenyl)iminoazanium [DPPH] Reagents by Effective Magnetic Moment Method. ANAL SCI 2018; 34:965-971. [PMID: 30101893 DOI: 10.2116/analsci.18p120] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Di(phenyl)-(2,4,6-trinitrophenyl)iminoazanium [DPPH] is widely used as a standard for measuring the number of free radicals. Here, we evaluated the number of free radicals of "DPPH" reagents from three manufacturers by effective magnetic moment method. Interestingly, the reagents from different manufacturers had varying temperature dependencies for both magnetic moment and g-value at low temperatures. As a result, the maximum relative difference among the three reagents on the number of free radicals per unit mass was 20%. Carbon hydrogen nitrogen (CHN) analyses, high-resolution EPR measurements, FT-IR measurement, and NMR measurement confirmed that a major component of only one among the three reagents was "pure" DPPH. The evaluated purity based on free radical content was 0.998 kg kg-1 with expanded uncertainty of 0.036 kg kg-1. The other two reagents were found to be contaminated by several % of benzene in the DPPH crystal structure.
Collapse
|
45
|
A Benzene-1,3,5-Triaminyl Radical Fused with Zn II -Porphyrins: Remarkable Stability and a High-Spin Quartet Ground State. Angew Chem Int Ed Engl 2018; 57:3733-3736. [PMID: 29442422 DOI: 10.1002/anie.201801080] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Indexed: 11/06/2022]
Abstract
A benzene-1,3,5-triaminyl radical fused with three ZnII -porphyrins was synthesized through a three-fold oxidative fusion reaction of 1,3,5-tris(ZnII -porphyrinylamino)benzene followed by oxidation with PbO2 as key steps. This triaminyl radical has been shown to possess a quartet ground state with a doublet-quartet energy gap of 3.1 kJ mol-1 by superconducting quantum interference device (SQUID) studies. Despite its high-spin nature, this triradical is remarkably stable, which allows its separation and recrystallization under ambient conditions. Moreover, this triradical can be stored as a solid for more than one year without serious deterioration. The high stability of the triradical is attributed to effective spin delocalization over the porphyrin segments and steric protection at the nitrogen centers and the porphyrin meso positions.
Collapse
|
46
|
Abstract
We study operation of a new device, the superconducting differential double contour interferometer (DDCI), in the application for the ultrasensitive detection of magnetic flux and for digital read out of the state of the superconducting flux qubit. DDCI consists of two superconducting contours weakly coupled by Josephson junctions. In such a device a change of the critical current, caused by an external magnetic flux or a nearby electric current, happens in a step-like manner when the angular momentum quantum number changes by one in one of the two contours. With a choice of parameters, the DDCI may outperform traditional superconducting quantum interference devices.
Collapse
|
47
|
Biosensing Using Magnetic Particle Detection Techniques. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2300. [PMID: 28994727 PMCID: PMC5676660 DOI: 10.3390/s17102300] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Revised: 08/26/2017] [Accepted: 08/30/2017] [Indexed: 02/03/2023]
Abstract
Magnetic particles are widely used as signal labels in a variety of biological sensing applications, such as molecular detection and related strategies that rely on ligand-receptor binding. In this review, we explore the fundamental concepts involved in designing magnetic particles for biosensing applications and the techniques used to detect them. First, we briefly describe the magnetic properties that are important for bio-sensing applications and highlight the associated key parameters (such as the starting materials, size, functionalization methods, and bio-conjugation strategies). Subsequently, we focus on magnetic sensing applications that utilize several types of magnetic detection techniques: spintronic sensors, nuclear magnetic resonance (NMR) sensors, superconducting quantum interference devices (SQUIDs), sensors based on the atomic magnetometer (AM), and others. From the studies reported, we note that the size of the MPs is one of the most important factors in choosing a sensing technique.
Collapse
|
48
|
Detection of Plasma Biomarkers Using Immunomagnetic Reduction: A Promising Method for the Early Diagnosis of Alzheimer's Disease. Neurol Ther 2017; 6:37-56. [PMID: 28733955 PMCID: PMC5520821 DOI: 10.1007/s40120-017-0075-7] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Indexed: 12/20/2022] Open
Abstract
Alzheimer's disease (AD) is the most common form of dementia. The development of assay technologies able to diagnose early-stage AD is important. Blood tests to detect biomarkers, such as amyloid and total Tau protein, are among the most promising diagnostic methods due to their low cost, low risk, and ease of operation. However, such biomarkers in blood occur at extremely low levels and are difficult to detect precisely. In the early 2000s, a highly sensitive assay technology, immunomagnetic reduction (IMR), was developed. IMR involves the use of antibody-functionalized magnetic nanoparticles dispersed in aqueous solution. The concentrations of detected molecules are converted to reductions in the ac magnetic susceptibility of this reagent due to the association between the magnetic nanoparticles and molecules. To achieve ultra-high sensitivity, a high-Tc superconducting-quantum-interference-device (SQUID) ac magnetosusceptometer was designed and applied to detect the tiny reduction in the ac magnetic susceptibility of the reagent. Currently, a 36-channeled high-Tc SQUID-based ac magnetosusceptometer is available. Using the reagent and this analyzer, extremely low concentrations of amyloid and total Tau protein in human plasma could be detected. Further, the feasibility of identifying subjects in early-stage AD via assaying plasma amyloid and total Tau protein is demonstrated. The results show a diagnostic accuracy for prodromal AD higher than 80% and reveal the possibility of screening for early-stage AD using SQUID-based IMR.
Collapse
|
49
|
Current-Phase Relation of Ballistic Graphene Josephson Junctions. NANO LETTERS 2017; 17:3396-3401. [PMID: 28474892 PMCID: PMC5474691 DOI: 10.1021/acs.nanolett.7b00097] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 05/03/2017] [Indexed: 05/22/2023]
Abstract
The current-phase relation (CPR) of a Josephson junction (JJ) determines how the supercurrent evolves with the superconducting phase difference across the junction. Knowledge of the CPR is essential in order to understand the response of a JJ to various external parameters. Despite the rising interest in ultraclean encapsulated graphene JJs, the CPR of such junctions remains unknown. Here, we use a fully gate-tunable graphene superconducting quantum intereference device (SQUID) to determine the CPR of ballistic graphene JJs. Each of the two JJs in the SQUID is made with graphene encapsulated in hexagonal boron nitride. By independently controlling the critical current of the JJs, we can operate the SQUID either in a symmetric or asymmetric configuration. The highly asymmetric SQUID allows us to phase-bias one of the JJs and thereby directly obtain its CPR. The CPR is found to be skewed, deviating significantly from a sinusoidal form. The skewness can be tuned with the gate voltage and oscillates in antiphase with Fabry-Pérot resistance oscillations of the ballistic graphene cavity. We compare our experiments with tight-binding calculations that include realistic graphene-superconductor interfaces and find a good qualitative agreement.
Collapse
|
50
|
Side Gate Tunable Josephson Junctions at the LaAlO 3/SrTiO 3 Interface. NANO LETTERS 2017; 17:715-720. [PMID: 28071920 PMCID: PMC5343548 DOI: 10.1021/acs.nanolett.6b03820] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 01/07/2017] [Indexed: 05/22/2023]
Abstract
Novel physical phenomena arising at the interface of complex oxide heterostructures offer exciting opportunities for the development of future electronic devices. Using the prototypical LaAlO3/SrTiO3 interface as a model system, we employ a single-step lithographic process to realize gate-tunable Josephson junctions through a combination of lateral confinement and local side gating. The action of the side gates is found to be comparable to that of a local back gate, constituting a robust and efficient way to control the properties of the interface at the nanoscale. We demonstrate that the side gates enable reliable tuning of both the normal-state resistance and the critical (Josephson) current of the constrictions. The conductance and Josephson current show mesoscopic fluctuations as a function of the applied side gate voltage, and the analysis of their amplitude enables the extraction of the phase coherence and thermal lengths. Finally, we realize a superconducting quantum interference device in which the critical currents of each of the constriction-type Josephson junctions can be controlled independently via the side gates.
Collapse
|