1
|
Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument. Am J Clin Pathol 2024:aqae040. [PMID: 38709595 DOI: 10.1093/ajcp/aqae040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 03/16/2024] [Indexed: 05/08/2024] Open
Abstract
OBJECTIVES The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences. METHODS Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated. RESULTS The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples. CONCLUSIONS Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.
Collapse
|
2
|
Pharmacodynamics Research on Danggui-Shaoyao-San through Body Fluid Indexes of Spleen Deficiency-water Dampness Rats using Bioimpedance Technology. Curr Pharm Biotechnol 2023:CPB-EPUB-135743. [PMID: 37921128 DOI: 10.2174/0113892010243018231025065109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 08/23/2023] [Accepted: 09/19/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND Spleen deficiency-water dampness symptom is closely related to body fluid-mediated organism metabolism and circulation. However, previous clinical evaluation of spleen deficiency-water dampness model was based only on body weight, D-xylose excretion rate, serum gastrin content, etc. Therefore, we established a large sample of normal rats and model rats experiment to verify the scientific nature of bio-impedance measuring body fluid indexes for evaluation of the modeling state. Pharmacodynamics research on Danggui-Shaoyao- San (DSS) was conducted through body fluid index changes of rats using bio-impedance technology. METHODS A spleen deficiency-water dampness symptom rat model was established through an inappropriate diet combined with excess fatigue. Experimental rats were divided into a normal control group, a model control group, a positive drug control group (hydrochlorothiazide), a blood-activating group, a water-disinhibiting group, and a DSS group. Total Body Water/Body Weight (TBW%), extracellular fluid/total body water content (ECF%), intracellular fluid/total body water content (ICF%), extracellular fluid/intracellular fluid (ECF/ICF), fat mass/body weight (FM%), fat-free mass/body weight (FFM%), and fat mass/fat-free mass (FM/FFM) of 150 rats were detected by a Bio-Imp Vet Body analyzer. RESULTS The TBW% of the model control group increased significantly, and the FM/FFM was significantly reduced compared with the normal group (P < 0.05) (P < 0.01), showing symptoms of spleen deficiency and diarrhea; the TBW% of the blood-activating group, and the waterdisinhibiting group decreased significantly, and the FM/FFM increased significantly (P < 0.05) (P < 0.01). The TBW% and FM/FFM in the water-disinhibiting group had returned to nearnormal values compared with the model control group. The blood-activating and waterdisinhibiting split prescriptions in DSS are both effective in treating spleen deficiency-water dampness rats. Comparatively, the fluid-regulating effect of split prescriptions in DSS was even stronger than that of DSS as shown in the present study. CONCLUSIONS These findings suggest that using bio-impedance technology to measure body fluid indexes can pave a road for further exploring the molecular mechanism of the reason why the blood-activating and disinhibit-water split prescriptions in DSS are both effective in treating spleen deficiency-water dampness rats.
Collapse
|
3
|
Revisiting blood pressure and body fluid status. Clin Sci (Lond) 2023; 137:755-767. [PMID: 37199255 DOI: 10.1042/cs20220500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 04/27/2023] [Accepted: 05/10/2023] [Indexed: 05/19/2023]
Abstract
Homeostasis of body fluid is a key component for maintaining health. An imbalance of body sodium and water causes various pathological states, such as dehydration, volume overload, hypertension, cardiovascular and renal diseases, and metabolic disorders. Conventional concepts regarding physiology and pathophysiology of body sodium and water balance have been established by several assumptions. These assumptions are that the kidneys are the master regulator of body sodium and water content, and that sodium moves inside the body in parallel with water. However, recent clinical and basic studies have proposed alternative concepts. These concepts are that body sodium and water balance are regulated by various organs and multiple factors, such as physical activity and the environment, and that sodium accumulates locally in tissues independently of the blood status and/or water. Various concerns remain unclear, and the regulatory mechanism of body sodium, fluid, and blood pressure needs to be readdressed. In the present review article, we discuss novel concepts regarding the regulation of body sodium, water, and blood pressure with a particular focus on the systemic water conservation system and fluid loss-triggered elevation in blood pressure.
Collapse
|
4
|
Application and Prospect of RNA Profiling Analysis in Forensic Body Fluid Identification. FA YI XUE ZA ZHI 2022; 38:763-773. [PMID: 36914393 DOI: 10.12116/j.issn.1004-5619.2021.510707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
In forensic physical evidence identification, the accurate identification of the individual origin and their body fluid composition of the biological samples obtained from the crime scene play a critical role in determining the nature of a crime. In recent years, RNA profiling has become one of the fastest developing methods for body fluids identification. Due to the characteristics of tissue or body fluid specific expression, various types of RNA markers have been proven to be promising candidate markers for body fluids identification in previous studies. This review summarizes the research progress of RNA markers in body fluids identification, including the RNA markers that have been effectively verified in current research and their advantages and disadvantages. Meanwhile, this review prospects the application of RNA markers in forensic medicine.
Collapse
|
5
|
Application Value and Research Progress of Human Microbiome in Sexual Assault Cases. FA YI XUE ZA ZHI 2022; 38:774-782. [PMID: 36914394 DOI: 10.12116/j.issn.1004-5619.2021.511101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
In recent years, sexual assault cases have been on the rise, seriously infringing the legitimate rights and interests of women and children, causing widespread concern in society. DNA evidence has become the key evidence to prove the facts in sexual assault cases, but lack of DNA evidence or only DNA evidence in some sexual assault cases leads to unclear facts and insufficient evidence. With the emergence of high-throughput sequencing technology and the development of bioinformatics and artificial intelligence, new progress has been made in the study of human microbiome. Researchers have begun to use human microbiome for difficult sexual assault cases indentification. This paper reviews the characteristics of human microbiome, and its application value in the inferences of the body fluid stain origin, the sexual assault method, the crime time, etc. In addition, the challenges faced by the application of the human microbiome in practical case handling, the solutions and future development potential are analyzed and prospected.
Collapse
|
6
|
Association of body fluid distribution with obstructive sleep apnea in pregnant individuals with a body mass index ≥ 40 kg·m 2-a prospective observational feasibility study. Can J Anaesth 2022; 69:1432-1434. [PMID: 36056279 DOI: 10.1007/s12630-022-02311-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 06/04/2022] [Accepted: 06/28/2022] [Indexed: 10/14/2022] Open
|
7
|
Concentration of cephalothin in body fluids and tissue samples of Thoroughbred horses. J Equine Sci 2022; 33:51-54. [PMID: 36196140 PMCID: PMC9522621 DOI: 10.1294/jes.33.51] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 06/14/2022] [Indexed: 12/05/2022] Open
Abstract
Cephalothin (CET) concentrations in body fluids (plasma, synovial fluid, pleural fluid,
peritoneal fluid, and aqueous humor) and tissue samples (bone, lung, jejunum, hoof, and
subcutaneous tissue) were investigated to consider the treatment of infectious diseases in
horses. CET 22 mg/kg body weight was intravenously administered to 12 horses. Samples were
collected from four different horses at 1, 3, and 5 hr after administration. The CET
concentration in body fluids other than aqueous humor was maintained above the
MIC90 values of Streptococcus zooepidemicus and Staphylococcus aureus until 5
hr, but it was not maintained above that of S. aureus in bone. CET (22 mg/kg twice a day)
is effective for septic arthritis, pleuritis, and peritonitis caused by gram-positive
bacteria but ineffective for osteomyelitis.
Collapse
|
8
|
Electrochemical Sensors for the Detection of Reactive Oxygen Species in Biological Systems: A Critical Review. Crit Rev Anal Chem 2022:1-33. [PMID: 35867547 DOI: 10.1080/10408347.2022.2098669] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Reactive oxygen species (ROS) involving superoxide anion, hydrogen peroxide and hydroxyl radical play important role in human health. ROS are known to be the markers of oxidative stress associated with different pathologies including neurodegenerative and cardiovascular diseases, as well as cancer. Accordingly, ROS level detection in biological systems is an essential problem for biomedical and analytical research. Electrochemical methods seem to have promising prospects in ROS determination due to their high sensitivity, rapidity, and simple equipment. This review demonstrates application of modern electrochemical sensors for ROS detection in biological objects (e.g., cell lines and body fluids) over a decade between 2011 and 2021. Particular attention is paid to sensors materials and various types of modifiers for ROS selective detection. Moreover, the sensors comparative characteristics, their main advantages, disadvantages and their possibilities and limitations are discussed.
Collapse
|
9
|
Fast and Sensitive Quantification of AccQ-Tag Derivatized Amino Acids and Biogenic Amines by UHPLC-UV Analysis from Complex Biological Samples. Metabolites 2022; 12:metabo12030272. [PMID: 35323715 PMCID: PMC8949038 DOI: 10.3390/metabo12030272] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 03/18/2022] [Accepted: 03/20/2022] [Indexed: 01/27/2023] Open
Abstract
Metabolomic analysis of different body fluids bears high importance in medical sciences. Our aim was to develop and validate a fast UHPLC-UV method for the analysis of 33 amino acids and biogenic amines from complex biological samples. AccQ-Tag derivatization was conducted on target molecules and the derivatized targets were analyzed by UHPLC-UV. The detection of the analytes was carried out with UV analysis and by Selected Reaction Monitoring (SRM)-based targeted mass spectrometry. The method was validated according to the FDA guidelines. Serum and non-stimulated tear samples were collected from five healthy individuals and the samples were analyzed by the method. The method was successfully validated with appropriate accuracy and precision for all 33 biomolecules. A total of 29 analytes were detected in serum samples and 26 of them were quantified. In the tears, 30 amino acids and biogenic amines were identified and 20 of them were quantified. The developed and validated UHPLC-UV method enables the fast and precise analysis of amino acids and biogenic amines from complex biological samples.
Collapse
|
10
|
Comparative Evaluation of Body Fluid Analysis by Sysmex XN Hematology Analyzers, CellaVision, Manual Microscopy and Multicolor Flow Cytometry. ANNALS OF CLINICAL AND LABORATORY SCIENCE 2022; 52:314-322. [PMID: 35414510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
OBJECTIVE The aim of this study was to investigate the correlation between instrumental and morphological cell differential methods in body fluid (BF) samples. METHODS Forty ascitic (AF) and forty cerebrospinal (CSF) fluid samples were measured with Sysmex XN1000 and XN2000 instruments in BF mode. Flow cytometry (FC) was carried out with FACS Canto II. From the centrifuged cytospin preparations mononuclear (MN%) and polymorphonuclear (PMN%) cell percentages were determined using optical microscopy (OM) and a digital cell morphology system CellaVision (CV). RESULTS Both Passing-Bablok and Bland-Altman analysis showed strong correlation between the hematology analyzers for total cell count (TC), white blood cell count (WBC), MN%, and PMN% in BFs. With slightly inferior results, all other WBC differential methods showed acceptable correlation. Passing-Bablok regression analysis yielded a slope encompassing 1.0 in all method comparisons except for three scenarios in CSF. The bias calculated with Bland-Altman plots was comprised between -6.05% and 6.05%. Strong correlations were found when comparing XN1000, XN2000, and CV to OM and FC method with linear regression analysis (r values between 0.905 and 0.984). CONCLUSION We found strong correlation between instrumental and manual morphological WBC differential methods when testing BF samples containing no tumor cells.
Collapse
|
11
|
Clinical application of an algorithm to screen for malignant cells in body fluids using an automated hematology analyzer. Int J Lab Hematol 2022; 44:483-489. [PMID: 35174970 DOI: 10.1111/ijlh.13813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 01/10/2022] [Accepted: 01/29/2022] [Indexed: 11/27/2022]
Abstract
INTRODUCTION The detection of malignant cells in body fluids (BF) with an automated hematology analyzer has been proposed as an alternative to morphological examination owing to its various advantages; however, its limitations have also been highlighted. In this study, we devised a practical algorithm to screen for malignant cells in BFs using an automated hematology analyzer. METHODS A total of 558 BF samples, including 232 cerebrospinal fluid (CSF) samples and 326 non-CSF samples, were consecutively collected. Thereafter, the results obtained using the BF mode of Sysmex XN-350 (Sysmex, Kobe, Japan) were compared with the cytological diagnosis. A cutoff was also established to screen for malignant cells using receiver operating characteristic (ROC) curve analysis based on the final clinical judgment. RESULTS The automated hematology analyzer showed a moderate correlation or good agreement with the existing cytological diagnosis. Further, of the ROC curves for detecting malignant cells, the absolute value of highly fluorescent cells on BF (HF-BF) in total body fluids showed the highest area under the curve (0.85 [95% confidence interval 0.82-88], p < .0001, Youden index >7×106 /L, sensitivity 93%, and specificity 65%). CONCLUSION An automated hematology analyzer could function as a complement to cytological examination. We propose a practical and comprehensive algorithm for cytological examination that requires low- and high-resolution microscopy based on the absolute value of HF-BF in BF samples suspected of malignancy. This algorithm can more usefully detect malignant cells while taking advantage of the automated analyzer and cytological examination.
Collapse
|
12
|
On the Identification of Body Fluids and Tissues: A Crucial Link in the Investigation and Solution of Crime. Genes (Basel) 2021; 12:1728. [PMID: 34828334 PMCID: PMC8617621 DOI: 10.3390/genes12111728] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 10/26/2021] [Accepted: 10/26/2021] [Indexed: 12/13/2022] Open
Abstract
Body fluid and body tissue identification are important in forensic science as they can provide key evidence in a criminal investigation and may assist the court in reaching conclusions. Establishing a link between identifying the fluid or tissue and the DNA profile adds further weight to this evidence. Many forensic laboratories retain techniques for the identification of biological fluids that have been widely used for some time. More recently, many different biomarkers and technologies have been proposed for identification of body fluids and tissues of forensic relevance some of which are now used in forensic casework. Here, we summarize the role of body fluid/ tissue identification in the evaluation of forensic evidence, describe how such evidence is detected at the crime scene and in the laboratory, elaborate different technologies available to do this, and reflect real life experiences. We explain how, by including this information, crucial links can be made to aid in the investigation and solution of crime.
Collapse
|
13
|
Scientific and Regulatory Policy Committee Points to Consider: Biological Sample Retention From Nonclinical Toxicity Studies. Toxicol Pathol 2021; 50:252-265. [PMID: 34702102 DOI: 10.1177/01926233211049156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Samples of biologic specimens and their derivatives (eg, wet tissues, paraffin-embedded tissue blocks, histology slides, frozen tissues, whole blood, serum/plasma, and urine) are routinely collected during the course of nonclinical toxicity studies. Good Laboratory Practice regulations and/or guidance specify minimum requirements for specimen retention duration, with the caveat that retention of biologic specimens need not extend beyond the duration of sample stability. However, limited availability of published data regarding stability for various purposes following storage of each specimen type has resulted in confusion, uncertainty, and inconsistency as to the appropriate duration for storage of these specimens. To address these issues, a working group of the Society of Toxicologic Pathology Scientific and Regulatory Policy Committee was formed to review published information, regulations, and guidance pertinent to this topic and to summarize the current practices and rationales for retention duration through a survey-based approach. Information regarding experiences reaccessing biologic specimens and performing sample stability investigations was also collected. Based on this combined information, the working group developed several points to consider that may be referenced when developing or revising sample retention practices. [Box: see text].
Collapse
|
14
|
Bioimpedance as a measure of fluid status in critically ill patients: A systematic review. Acta Anaesthesiol Scand 2021; 65:1155-1167. [PMID: 34036559 DOI: 10.1111/aas.13924] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 05/05/2021] [Accepted: 05/06/2021] [Indexed: 12/22/2022]
Abstract
OBJECTIVE Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically ill patients. DATA SOURCES PubMed and Embase up till March 2021 were systematically searched (PROSPERO: CRD42020157436). STUDY SELECTION Eligibility criteria were studies reporting original data from cohorts of adult patients in intensive care units and doing at least one whole-body bioimpedance and one reference test. In addition, studies assessing internal reproducibility were included. DATA EXTRACTION An extraction form was designed for the purpose. DATA SYNTHESIS Nine hundred five studies were screened for eligibility, and 28 studies, comprising 1482 individual patients, were included in the final analysis. Eight studies compared bioimpedance with a gold standard, and two of those reported the results adequate. We found a low mean difference, but the 95% limits of agreements had wide limits. The remaining studies applied different surrogates as reference tests. Correlations ranged from 0.05 to 0.99. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) certainty of evidence for all outcomes was very low. CONCLUSIONS The accuracy of bioimpedance as a measure for fluids in critically ill patients in the intensive care unit cannot be determined. Due to the lack of a gold standard, numerous studies compared bioimpedance with surrogate outcomes with great variability in both designs and results. Assessing the internal reproducibility of bioimpedance had the same limitations, but the studies overall reported good internal reproducibility.
Collapse
|
15
|
Forensic Analysis of Human Microbiome in Skin and Body Fluids Based on Geographic Location. Front Cell Infect Microbiol 2021; 11:695191. [PMID: 34458160 PMCID: PMC8388931 DOI: 10.3389/fcimb.2021.695191] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 07/26/2021] [Indexed: 01/16/2023] Open
Abstract
High-throughput DNA sequencing technologies have facilitated the in silico forensic analysis of human microbiome. Specific microbial species or communities obtained from the crime scene provide evidence of human contacts and their body fluids. The microbial community is influenced by geographic, ethnic, lifestyle, and environmental factors such as urbanization. An understanding of the effects of these external stressors on the human microbiome and determination of stable and changing elements are important in selecting appropriate targets for investigation. In this study, the Forensic Microbiome Database (FMD) (http://www.fmd.jcvi.org) containing the microbiome data of various locations in the human body in 35 countries was used. We focused on skin, saliva, vaginal fluid, and stool and found that the microbiome distribution differed according to the body part as well as the geographic location. In the case of skin samples, Staphylococcus species were higher than Corynebacterium species among Asians compared with Americans. Holdemanella and Fusobacterium were specific in the saliva of Koreans and Japanese populations. Lactobacillus was found in the vaginal fluids of individuals in all countries, whereas Serratia and Enterobacter were endemic to Bolivia and Congo, respectively. This study is the first attempt to collate and describe the observed variation in microbiomes from the forensic microbiome database. As additional microbiome databases are reported by studies worldwide, the diversity of the applications may exceed and expand beyond the initial identification of the host.
Collapse
|
16
|
A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment. Medicine (Baltimore) 2021; 100:e24852. [PMID: 33725957 PMCID: PMC7982217 DOI: 10.1097/md.0000000000024852] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 01/26/2021] [Indexed: 01/05/2023] Open
Abstract
We evaluated the capacity of the XN-350 instrument to analyze 3 different types of body fluid samples under "body fluid mode."The performance of XN-350 was evaluated in terms of precision, carryover, limit of blank, limit of detection, limit of quantification, and linearity. Cell enumeration and differential data produced by the XN-350 were compared to manual chamber counting results in 63 cerebrospinal fluid (CSF), 51 ascitic fluid, and 51 pleural fluid (PF) samples. Comparisons between XN-350 versus Cytospin data were also performed in PF samples.The precision, carry-over, limit of blank, and linearity of the XN-350 were acceptable. The limits of detection for white blood cells (WBCs) and red blood cells were 1.0/μL, and 1,000.0/μL, respectively; the corresponding limits of quantitation (LOQs) were 5.0/μL and 2,000.0/μL, respectively. The XN-350's cell enumeration and differential counting correlated well with those of manual chamber counting for all 3 sample types (except for differential counting in CSF samples), particularly parameters involving monocytes (r = 0.33) and mononuclear cells (MO- body fluid [BF]; r = 0.26), as well as total cell (TC-BF) enumeration (r = 0.50) and WBC-BF (r = 0.50) in PF samples. The MO-BF in CSF samples differed significantly from manual chamber counting results, but neither TC-BF nor WBC-BF in PF samples did. The XN-350 also showed good correlations with Cytospin analyses for differential counting of neutrophils, lymphocytes, and monocytes in PF samples. The differential counting of eosinophils via the XN-350 and Cytospin were not significantly correlated, but the difference between them was not significant.The XN-350 is an acceptable alternative to manual fluid analysis. Samples with low cellularity around the LOQ should be checked manually. Moreover, manual differential counting should be performed on CSF samples, particularity those with low cell numbers.
Collapse
|
17
|
Non-Invasive Biomarkers for Early Detection of Breast Cancer. Cancers (Basel) 2020; 12:E2767. [PMID: 32992445 PMCID: PMC7601650 DOI: 10.3390/cancers12102767] [Citation(s) in RCA: 85] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 09/23/2020] [Accepted: 09/24/2020] [Indexed: 12/24/2022] Open
Abstract
Breast cancer is the most common cancer in women worldwide. Accurate early diagnosis of breast cancer is critical in the management of the disease. Although mammogram screening has been widely used for breast cancer screening, high false-positive and false-negative rates and radiation from mammography have always been a concern. Over the last 20 years, the emergence of "omics" strategies has resulted in significant advances in the search for non-invasive biomarkers for breast cancer diagnosis at an early stage. Circulating carcinoma antigens, circulating tumor cells, circulating cell-free tumor nucleic acids (DNA or RNA), circulating microRNAs, and circulating extracellular vesicles in the peripheral blood, nipple aspirate fluid, sweat, urine, and tears, as well as volatile organic compounds in the breath, have emerged as potential non-invasive diagnostic biomarkers to supplement current clinical approaches to earlier detection of breast cancer. In this review, we summarize the current progress of research in these areas.
Collapse
|
18
|
The cytopathological spectrum of lymphomas in effusions in a tertiary center in Taiwan. Diagn Cytopathol 2020; 49:232-240. [PMID: 32975910 DOI: 10.1002/dc.24626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/14/2020] [Accepted: 09/16/2020] [Indexed: 12/13/2022]
Abstract
Lymphomas presenting in effusions could either be primary or secondary, with very limited data from Taiwan. METHODS We retrospectively reviewed effusion lymphomas from our archives in a tertiary center from July 2011 to June 2019. RESULTS We identified 59 specimens from 43 patients, including 7 cases with primary effusion lymphoma (PEL) and 36, secondary effusion involvement. Half of the secondary cases presented concurrently with effusion lymphoma, while the remaining half-experienced effusion lymphoma during disease progression. All patients with PELs were males with a median age of 77 and presented with massive pleural effusion. None was HIV-related. Two (29%) PEL cases were positive for human herpes virus 8 (HHV8). The only case with plasmablastic phenotype in the PEL group was positive for both HHV8 and EBV. Four patients died shortly after diagnosis; while the remaining three were alive at the last follow-up (two at 13 months and one at 99 months). Of the secondary cases, diffuse large B-cell lymphoma/high grade B-cell lymphoma was the most common (n = 16, 44%), followed by mantle cell lymphoma (n = 5, 14%). Only 8 cases (22%) were T-cell neoplasms. Prognosis for patients with secondary effusion involvement was dismal, with 1- and 2-year overall survival rates at 17% and 8%, respectively. CONCLUSION We found a wide cytopathological spectrum of effusion lymphoma in Taiwan. Most of our PEL cases were distinct from that defined in the World Health Organization scheme by a B-cell phenotype, HHV8-negativity, and absence of immunodeficiency. As compared to PEL cases, the prognosis of those with secondary involvement was extremely poor.
Collapse
|
19
|
Sodium Handling and Interaction in Numerous Organs. Am J Hypertens 2020; 33:687-694. [PMID: 32198504 DOI: 10.1093/ajh/hpaa049] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/10/2020] [Accepted: 03/17/2020] [Indexed: 12/27/2022] Open
Abstract
Salt (NaCl) is a prerequisite for life. Excessive intake of salt, however, is said to increase disease risk, including hypertension, arteriosclerosis, heart failure, renal disease, stroke, and cancer. Therefore, considerable research has been expended on the mechanism of sodium handling based on the current concepts of sodium balance. The studies have necessarily relied on relatively short-term experiments and focused on extremes of salt intake in humans. Ultra-long-term salt balance has received far less attention. We performed long-term salt balance studies at intakes of 6, 9, and 12 g/day and found that although the kidney remains the long-term excretory gate, tissue and plasma sodium concentrations are not necessarily the same and that urinary salt excretion does not necessarily reflect total-body salt content. We found that to excrete salt, the body makes a great effort to conserve water, resulting in a natriuretic-ureotelic principle of salt excretion. Of note, renal sodium handling is characterized by osmolyte excretion with anti-parallel water reabsorption, a state-of-affairs that is achieved through the interaction of multiple organs. In this review, we discuss novel sodium and water balance concepts in reference to our ultra-long-term study. An important key to understanding body sodium metabolism is to focus on water conservation, a biological principle to protect from dehydration, since excess dietary salt excretion into the urine predisposes to renal water loss because of natriuresis. We believe that our research direction is relevant not only to salt balance but also to cardiovascular regulatory mechanisms.
Collapse
|
20
|
Oxidative stress response associates with the teratogenic effects of benzyl butyl phthalate (BBP). Toxicol Res (Camb) 2020; 9:222-229. [PMID: 32670553 DOI: 10.1093/toxres/tfaa022] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 03/07/2020] [Accepted: 03/23/2020] [Indexed: 11/13/2022] Open
Abstract
Benzyl butyl phthalate (BBP) is a persistent environmental pollutant. BBP exposure and the possible effects on human neural tube defects (NTDs) remain elusive. In this study, we found that the detection ratio of positive BBP and its metabolites in maternal urine was obviously higher in NTDs' population than that in normal controls by GC-MS (P < 0.01, P < 0.05, respectively). Animal experiments showed that BBP treatment induced developmental toxicity in chick embryo by enhancing the levels of oxidative stress and cell apoptosis (P < 0.01). More interestingly, the supplement of high-dose choline (CHO, 10 5 μg/mL) could partially restore the teratogenic effects of BBP by inhibiting the occurrence of oxidative stress. Our data collectively suggest that BBP exposure may disturb neural tube development by strengthening oxidative stress. CHO can partially restore the toxicity effects of BBP. This study may provide new insight for NTD prevention.
Collapse
|
21
|
Non-Exosomal and Exosomal Circulatory MicroRNAs: Which Are More Valid as Biomarkers? Front Pharmacol 2020; 10:1500. [PMID: 32038230 PMCID: PMC6984169 DOI: 10.3389/fphar.2019.01500] [Citation(s) in RCA: 108] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 11/19/2019] [Indexed: 12/12/2022] Open
Abstract
MicroRNAs (miRNAs) are a group of small non-coding RNAs with approximately 19–25 nucleotides that are involved in regulating a range of developmental and physiological processes. Non-exosomal circulating and exosomal miRNAs have also been proposed to be useful in diagnostics as biomarkers for diseases and different types of cancer. In this review, the quantity of miRNAs and of reliable experimental data analyses of miRNAs that come from exosomal and non-exosomal sources are discussed from the perspective of their use as biomarkers for cancer and other diseases, including viral infections, nervous system disorders, cardiovascular disorders, and diabetes. We summarize other research findings regarding the use of miRNA from these two sources as biomarkers in diagnostics and clinical use. The challenges in using miRNA from these two sources in cancer and disease diagnostics are evaluated and discussed. Validation of specific miRNA signatures as biomarkers is a critical milestone in diagnostics.
Collapse
|
22
|
Evaluation of high-fluorescence body fluid (HF-BF) parameter as a screening tool of malignancy in body fluids. INDIAN J PATHOL MICR 2019; 62:572-577. [PMID: 31611442 DOI: 10.4103/ijpm.ijpm_802_18] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Introduction Automated body fluid (BF) analysis is gradually replacing the traditional methods of cell counting in all BFs. This study was done to analyze the high-fluorescence (HF)-BF parameter generated on Sysmex XN-1000 and study its correlation with the presence of malignant cells in the body fluids. A correlation between manual and automated differential counts was also done. Materials and Methods A total of 1985 samples including 797 ascitic fluids (AF), 532 pleural fluids (PF), and 656 cerebrospinal fluids (CSF) were run on Sysmex XN-1000 in BF mode and cytopathology was available for 924 BFs including 389 AF, 379 PF, and 156 CSF. Both manual and automated methods were used for cell differential and cell morphology. Results Of the 924 samples with corresponding cytopathology, malignancy was found in 59 samples. The HF-BF%/100 WBCs (24.8 ± 72.5) and HF-BF#/μL (329.86 ± 932.35) for malignant BF samples were found to be significantly higher than the nonmalignant samples (4.41 ± 8.1) and (19.57 ± 61.91), respectively. Receiver-operator-characteristic curve cutoffs for all BF for percentage and absolute HF-BF were 2.85%/100 WBCs and >12/μL. A good correlation was found between the manual and automated WBC differential counts in all fluids except CSF with total count < 5/μL. Conclusions BFs can be reliably analyzed on automated analyzers. HF-BF parameter is helpful in identifying malignant samples but cannot be totally relied upon. If HF-BF%/# are above the lab-generated cutoffs, microscopy should be done. A complete validation study on HF-BF parameter in BF mode is desired to set the standards for the analysis of serious effusions.
Collapse
|
23
|
Abstract
BACKGROUND Chemistry testing is requested for body fluid (BF) specimens despite the lack of assays approved by the US Food and Drug Administration (FDA). The criteria for categorizing fluids as transudate or exudate are not validated across analyzers. OBJECTIVE To compare BF chemical analysis and classification by different analyzers. METHODS We analyzed 10 pleural and 18 peritoneal fluids with corresponding plasma specimens using the Vitros 5,1 FS; Abbott ARCHITECT ci8200; and Roche Modular P platforms. Total protein (TP) and lactate dehydrogenase (LDH) were measured for pleural fluids. Light's criteria were applied. Albumin was measured for peritoneal specimens, and the plasma-ascites-albumin gradient was calculated. RESULTS TP results showed agreement. The Vitros LDH assay produced higher fluid:plasma ratios. Classification by Light's criteria resulted in 1 discrepancy (ARCHITECT). Albumin results showed agreement. There were 2 discrepant gradient interpretations (Vitros). CONCLUSIONS These data suggest that analyses of pleural and peritoneal fluids using these platforms are diagnostically interchangeable.
Collapse
|
24
|
Isolation and Characterization of Small Extracellular Vesicles from Porcine Blood Plasma, Cerebrospinal Fluid, and Seminal Plasma. Proteomes 2019; 7:proteomes7020017. [PMID: 31027284 PMCID: PMC6630935 DOI: 10.3390/proteomes7020017] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 04/18/2019] [Accepted: 04/24/2019] [Indexed: 12/31/2022] Open
Abstract
Extracellular vesicles (EVs) are a highly attractive subject of biomedical research as possible carriers of nucleic acid and protein biomarkers. EVs released to body fluids enable indirect access to inner organs by so-called "liquid biopsies". Obtaining a high-quality EV sample with minimum contaminants is crucial for proteomic analyses using LC-MS/MS or other techniques. However, the EV content in various body fluids largely differs, which may hamper subsequent analyses. Here, we present a comparison of extracellular vesicle yields from blood plasma, cerebrospinal fluid, and seminal plasma using an experimental pig model. Pigs are widely used in biomedical research as large animal models with anatomy and physiology close to those of humans and enable studies (e.g., of the nervous system) that are unfeasible in humans. EVs were isolated from body fluids by differential centrifugation followed by ultracentrifugation. EVs were characterized according to protein yields and to the quality of the isolated vesicles (e.g., size distribution, morphology, positivity for exosome markers). In our experimental setting, substantial differences in EV amounts were identified among body fluids, with the seminal plasma being the richest EV source. The yields of pellet proteins from ultracentrifugation of 1 mL of porcine body fluids may help to estimate body fluid input volumes to obtain sufficient samples for subsequent proteomic analyses.
Collapse
|
25
|
Potential urine biomarkers for gestational hypertension and preeclampsia. Mol Med Rep 2019; 19:2463-2470. [PMID: 30720087 PMCID: PMC6423646 DOI: 10.3892/mmr.2019.9911] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Accepted: 12/17/2018] [Indexed: 11/22/2022] Open
Abstract
Differential proteomic technology was used to identify urine proteomic profile of gestational hypertension and preeclampsia. Urine samples were collected from 10 patients with gestational hypertension, 10 patients with mild preeclampsia, 10 patients with severe preeclampsia and 10 normal pregnancies and analyzed by 2‑D difference gel electrophoresis, then matrix assisted laser desorption ionization mass spectrometry was used to identify differential proteins. Subsequently, ELISA was used to verify the content variation of the identified proteins in 200 urine samples. In total, 30 differential proteins were identified. For prostaglandin‑H2 D‑isomerase (L‑PGDS), perlecan and other 15 proteins, the contents in patients with gestational hypertension were higher than that of normal pregnancies, but lower in mild and severe preeclampsia. By contrast, serum albumin and α‑1‑antitrypsin was lower in samples from patients with gestational hypertension and higher in patients with mild and severe preeclampsia compared with normal pregnancies. ELISA verified that the urinary concentration of L‑PGDS and perlecan were significantly lower in patients with preeclampsia than in normal pregnancies (P<0.05). Urine proteomics is a useful tool to identify potential biomarkers to distinguish between different types of hypertensive disorders in pregnancy. L‑PGDS and perlecan could potentially be used as markers to reflect the state of renal function, and may participate in the genesis and development of renal injury during preeclampsia.
Collapse
|
26
|
Urinary Pesticide Levels in Children and Adolescents Residing in Two Agricultural Communities in Mexico. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E562. [PMID: 30781414 PMCID: PMC6406912 DOI: 10.3390/ijerph16040562] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Accepted: 02/12/2019] [Indexed: 11/17/2022]
Abstract
The use of pesticides in agricultural activities has increased significantly during the last decades. Several studies have reported the health damage that results from exposure to pesticides. In Mexico, hundreds of communities depend economically on agricultural activities. The participation of minors in this type of activity and their exposure to pesticides represents a potential public health problem. A cross-sectional study was conducted, in which urine samples (first-morning urine) were taken from children under 15 years of age in both communities. A total of 281 urine samples obtained in both communities were processed for the determination of pesticides with high-performance liquid chromatography together with tandem mass spectrometry. In 100% of the samples, at least two pesticides of the 17 reported in the total samples were detected. The presence of malathion, metoxuron, and glyphosate was remarkable in more than 70% of the cases. Substantial differences were detected regarding the other compounds. It is necessary to carry out long-term studies to determine the damage to health resulting from this constant exposure and to inform the health authorities about the problem in order to implement preventive measures.
Collapse
|
27
|
Lack of harmonization in high fluorescent cell automated counts with body fluids mode in ascitic, pleural, synovial, and cerebrospinal fluids. Int J Lab Hematol 2019; 41:277-286. [PMID: 30758900 DOI: 10.1111/ijlh.12968] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 11/28/2018] [Accepted: 12/12/2018] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Cellular analysis in body fluids (BFs) provides important diagnostic information in various pathological settings. This study was hence aimed at comparing automated cell count obtained with Mindray BC-6800 (BC-BF) vs Sysmex XN-series (XN-BF) and evaluating other quantitative and qualitative information provided by these analyzers in ascitic (AF), pleural (PF), synovial (SF), and cerebrospinal (CSF) fluids. METHODS Three hundred and fifty-one samples (99 AFs, 45 PFs, 75 SFs, and 132 CSFs) were analyzed in parallel with BC-BF, XN-BF, and optical microscopy (OM). The study also included the assessment of diagnostic agreement among BC-BF, XN-BF, and OM. RESULTS The comparison of BC-BF vs XN-BF yielded slopes of Passing and Bablok regression always comprised between 0.9 and 1.0 except for EO-BF and HF-BF, whilst the intercepts ranged from -0.4 for MN-BF and 12.0 for PMN-BF. The bias was comprised between -103.3% and 67.1% for HF-BF and EO-BF, respectively. A significant bias was found for TC-BF, WBC-BF, HF-BF (negative bias) and for PMN-BF and EO-BF (positive bias). The agreement (Cohen's kappa) between XN-BF and BC-BF was always ≥0.7, ranging between 0.87 in CSFs and 0.94 in AFs, and that with OM was similar (ie, 0.85 and 0.96). CONCLUSION The cytometric analysis of BF samples using BC-BF and XN-BF is clinically favorable when appropriately combined with OM. Quantitative and qualitative parameters displayed optimal agreement, whilst instrument-specific cut-offs should be defined and implemented for HF-BF and EO-BF. Further efforts should be made for achieving better harmonization in cytometric analysis of BF samples.
Collapse
|
28
|
Epigenetic biomarkers of promoter DNA methylation in the new era of cancer treatment. Cancer Sci 2018; 109:3695-3706. [PMID: 30264476 PMCID: PMC6272087 DOI: 10.1111/cas.13812] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Revised: 09/20/2018] [Accepted: 09/22/2018] [Indexed: 12/21/2022] Open
Abstract
Promoter DNA methylation, which occurs on cytosine nucleotides across CpG islands, results in gene silencing and represents a major epigenetic alteration in human cancer. Methylation-specific PCR can amplify these modifications as markers in cancer cells. In the present work, we rigorously review the published literatures describing DNA methylation in the promoters of critical tumor suppressor genes; detection of promoter DNA methylation in various body fluids permits early detection of cancer cells during perioperative courses of clinical treatment. The latest whole-genome comprehensive explorations identified excellent epigenetic biomarkers that could be detected at high frequency with high specificity; these biomarkers, which are designated highly relevant methylation genes (HRMG), permit the discrimination of tumor tissues from the corresponding normal tissues; these markers are also associated with unique cancer phenotypes, including dismal prognosis. In humans, HRMG include the CDO1, GSHR, RASSF1 and SFRP1 genes, with these markers permitting discrimination depending on the organs tested. The combination of several HRMG increased the early detection of cancer and exhibited reliable surveillance potential in human body fluids. Cancer clinics using such epigenetic biomarkers are entering a new era of enhanced decision-making with the potential for improved cancer prognosis.
Collapse
|
29
|
[Na +] Increases in Body Fluids Sensed by Central Na x Induce Sympathetically Mediated Blood Pressure Elevations via H +-Dependent Activation of ASIC1a. Neuron 2018; 101:60-75.e6. [PMID: 30503172 DOI: 10.1016/j.neuron.2018.11.017] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 10/08/2018] [Accepted: 11/08/2018] [Indexed: 02/07/2023]
Abstract
Increases in sodium concentrations ([Na+]) in body fluids elevate blood pressure (BP) by enhancing sympathetic nerve activity (SNA). However, the mechanisms by which information on increased [Na+] is translated to SNA have not yet been elucidated. We herein reveal that sympathetic activation leading to BP increases is not induced by mandatory high salt intakes or the intraperitoneal/intracerebroventricular infusions of hypertonic NaCl solutions in Nax-knockout mice in contrast to wild-type mice. We identify Nax channels expressed in specific glial cells in the organum vasculosum lamina terminalis (OVLT) as the sensors detecting increases in [Na+] in body fluids and show that OVLT neurons projecting to the paraventricular nucleus (PVN) are activated via acid-sensing ion channel 1a (ASIC1a) by H+ ions exported from Nax-positive glial cells. The present results provide an insight into the neurogenic mechanisms responsible for salt-induced BP elevations.
Collapse
|
30
|
Changes in red blood cell volume during transition of heart failure status: a reflection of cellular hydration status? Scandinavian Journal of Clinical and Laboratory Investigation 2018; 78:305-311. [PMID: 29703089 DOI: 10.1080/00365513.2018.1466607] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
This study examined how changes in heart failure (HF) status induce changes in the index of erythrocyte hydration based on mean red blood cell volume (MCV). Data from 47 HF patients (32% men; 78.2 ± 9.7 years) that experienced worsening and recovery of HF were analysed. Blood tests included measurements of MCV, albumin, serum solutes and b-type natriuretic peptide (BNP). Among a total of 47 worsening HF events, changes in MCV were positively correlated with changes in body weight (r = 0.31, p = .034), serum sodium (r = 0.417, p = .0036), and chloride (r = 0.457, p = .0012), and negatively correlated with changes in blood urea nitrogen (r= -0.389, p = .0069) and creatinine (r= -0.494, p = .0004). At recovery from worsening of HF by conventional diuretic therapy, change in MCV was positively correlated with the change in body weight (r = 0.457, p = .0012), serum sodium (r = 0.466, p = .001) and chloride (r = 0.484, p = .0006). Multivariate regression analysis demonstrated an independent association between the increase in serum chloride and MCV from stability to worsening of HF (odds ratio [OR] 6.02, 95% confidence interval [CI] 1.09-33.2, p = .039) and the increase or absence of change in serum chloride concentration and preserved MCV after decongestion (OR 11.5, 95% CI 1.53-85.9, p = .017). In conclusion, this study demonstrates that the changes in MCV under transition in HF status do not reflect a change that occurs in parallel with changes in HF-related markers, such as body weight and serum BNP level, but is independently associated with a change in the serum chloride concentration. Whether changes in MCV actually reflect the bodily cellular hydration status warrants further research.
Collapse
|
31
|
Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples. J Clin Lab Anal 2018; 32:e22373. [PMID: 29314254 DOI: 10.1002/jcla.22373] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 11/27/2017] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. METHODS Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. RESULTS A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. CONCLUSION We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources.
Collapse
|
32
|
Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid. Int J Lab Hematol 2017; 40:26-33. [PMID: 28866874 DOI: 10.1111/ijlh.12723] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 06/26/2017] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Cellular analysis in cerebrospinal fluid (CSF) provides important diagnostic information in many pathological settings. The aim of this two-site study was to evaluate the Sysmex XN Body Fluid mode (XN-BF) for cell analysis of CSF compared to light microscopy (LM). METHODS Two hundred and seven consecutive CSF samples were analyzed in parallel with XN-BF and LM. The study also included the estimation of the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), carry-over and linearity of XN-BF module. RESULTS LoQ of white blood cells (WBC) was 3×106 cells/L; linearity was good and carry-over negligible. XN-BF parameters were compared to LM for the following cell classes: total cells, WBC, polymorphonuclear (PMN), and mononuclear (MN) cells. The bias ranged from 1.3 to 15.2×106 cells/L. The receiver operating characteristics curve analysis for WBC showed an area under the curve of 0.98, and the global diagnostic agreement was 95% at a cutoff of 5×106 cells/L. CONCLUSIONS XN-BF provides rapid and accurate counts in clinically relevant ranges of CSF values, thus providing a valuable alternative to conventional LM analysis. However, microscopic review remains advisable in samples with abnormal cell counts or high fluorescent (HF-BF) cell parameter exceeding 5×106 cells/L.
Collapse
|
33
|
Universal Precautions: Necessary Safety Procedures When Handling Human Blood, Body Fluids, and Specimens. ACTA ACUST UNITED AC 2017; 118:A.3P.1-A.3P.3. [PMID: 28762486 DOI: 10.1002/cpim.29] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Universal precautions are observed whenever handling human blood, body fluids, or specimens as a means of preventing exposure to blood-borne pathogens. This appendix outlines safety procedures to follow whenever undertaking research activities that involve human blood, body fluids, and specimens. © 2017 by John Wiley & Sons, Inc.
Collapse
|
34
|
Early detection of pancreatic cancer: Where are we now and where are we going? Int J Cancer 2017; 141:231-241. [PMID: 28240774 DOI: 10.1002/ijc.30670] [Citation(s) in RCA: 127] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 01/25/2017] [Accepted: 02/20/2017] [Indexed: 12/11/2022]
Abstract
Pancreatic cancer (PC) is one of the most lethal malignancies. Recent studies indicate that patients with incidentally diagnosed PC have better prognosis than those with symptoms and that there is a sufficient window for early detection. However, effective early diagnosis remains difficult and depends mainly on imaging modalities and the development of screening methodologies with highly sensitive and specific biomarkers. This review summarizes recent advances in effective screening for early diagnosis of PC using imaging modalities and novel molecular biomarkers discovered from various "omics" studies including genomics, epigenomics, non-coding RNA, metabonomics, liquid biopsy (CTC, ctDNA and exosomes) and microbiomes, and their use in body fluids (feces, urine and saliva). Although many biomarkers for early detection of PC have been discovered through various methods, larger scale and rigorous validation is required before their application in the clinic. In addition, more effective and specific biomarkers of PC are urgently needed.
Collapse
|
35
|
An infrared sensor analysing label-free the secondary structure of the Abeta peptide in presence of complex fluids. JOURNAL OF BIOPHOTONICS 2016; 9:224-234. [PMID: 25808829 DOI: 10.1002/jbio.201400145] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 02/19/2015] [Accepted: 03/01/2015] [Indexed: 06/04/2023]
Abstract
The secondary structure change of the Abeta peptide to beta-sheet was proposed as an early event in Alzheimer's disease. The transition may be used for diagnostics of this disease in an early state. We present an Attenuated Total Reflection (ATR) sensor modified with a specific antibody to extract minute amounts of Abeta peptide out of a complex fluid. Thereby, the Abeta peptide secondary structure was determined in its physiological aqueous environment by FTIR-difference-spectroscopy. The presented results open the door for label-free Alzheimer diagnostics in cerebrospinal fluid or blood. It can be extended to further neurodegenerative diseases. An immunologic ATR-FTIR sensor for Abeta peptide secondary structure analysis in complex fluids is presented.
Collapse
|
36
|
Non-coding RNAs in saliva: emerging biomarkers for molecular diagnostics. Int J Mol Sci 2015; 16:8676-98. [PMID: 25898412 PMCID: PMC4425103 DOI: 10.3390/ijms16048676] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 04/02/2015] [Accepted: 04/08/2015] [Indexed: 01/05/2023] Open
Abstract
Saliva is a complex body fluid that comprises secretions from the major and minor salivary glands, which are extensively supplied by blood. Therefore, molecules such as proteins, DNA, RNA, etc., present in plasma could be also present in saliva. Many studies have reported that saliva body fluid can be useful for discriminating several oral diseases, but also systemic diseases including cancer. Most of these studies revealed messenger RNA (mRNA) and proteomic biomarker signatures rather than specific non-coding RNA (ncRNA) profiles. NcRNAs are emerging as new regulators of diverse biological functions, playing an important role in oncogenesis and tumor progression. Indeed, the small size of these molecules makes them very stable in different body fluids and not as susceptible as mRNAs to degradation by ribonucleases (RNases). Therefore, the development of a non-invasive salivary test, based on ncRNAs profiles, could have a significant applicability to clinical practice, not only by reducing the cost of the health system, but also by benefitting the patient. Here, we summarize the current status and clinical implications of the ncRNAs present in human saliva as a source of biological information.
Collapse
|
37
|
Salivary extracellular noncoding RNA: emerging biomarkers for molecular diagnostics. Clin Ther 2015; 37:540-51. [PMID: 25795433 DOI: 10.1016/j.clinthera.2015.02.017] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Revised: 02/16/2015] [Accepted: 02/17/2015] [Indexed: 01/05/2023]
Abstract
Saliva is a complex body fluid that comprises secretions from the major and minor salivary glands, nourished by body's vasculature. Although many circulatory molecules (DNA, RNA, and proteins) can also be present in saliva, saliva harbors unique molecular constituents that can be discriminatory for oral and systemic disease screening and detection. Many studies have reported that salivary constituents can discriminate oral diseases (oral cancer and Sjögren's syndrome) and also systemic diseases (lung cancer, breast cancer, pancreatic cancer, and ovarian cancer). Noncoding RNAs (ncRNAs) are emerging new regulators of diverse biological functions, playing important roles in oncogenesis and tumor progression. Indeed, the short size of these molecules makes them stable in different body fluids such as urine, blood, and saliva, being not as susceptible as mRNAs to degradation by RNases. Here, the current status and clinical implications of the ncRNAs present in human saliva are reviewed for translational applications and basic biological research. The development of noninvasive salivary test (based on ncRNAs profiles) for disease detection could have effective applications into the clinical context with a translational significance as emerging molecular biomarkers for non-invasively disease detection, not only by reducing the cost to the health care system but also by benefitting patients.
Collapse
|
38
|
Simultaneous detection of circulating oncomiRs from body fluids for prostate cancer staging using nanographene oxide. ACS APPLIED MATERIALS & INTERFACES 2014; 6:14772-8. [PMID: 25158299 DOI: 10.1021/am504190a] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Circulating oncomiRs are highly stable diagnostic, prognostic, and therapeutic tumor biomarkers, which can reflect the status of the disease and response to cancer therapy. miR-141 is an oncomiR, which is overexpressed in advanced prostate cancer patients, whereas its expression is at the normal levels in the early stages of the disease. On the other hand, miR-21 is significantly elevated in the early stage, but not in the advanced prostate cancer. Here, we have demonstrated simultaneous detection of exogenous miR-21 and miR-141 from human body fluids including blood, urine and saliva using nanographene oxide. Our system enables us to specifically and reliably detect each oncomiR at different fluorescence emission channels from a large population of RNAs extracted from body fluids. We were also able to determine the content and the ratio of the miR-21 and miR-141 in 10 different miRNA cocktails composed of various, but unknown, concentrations of both oncomiRs. A strong agreement (around 90%) between the experimental results and the actual miRNA compositions was observed. Moreover, we have demonstrated that overexpressed miR-21 or miR-141 increases the fluorescence only at their signature wavelengths of 520 and 670 nm, respectively. The approach in this study combines two emerging fields of nanographene in biomedicine and the role of circulating miRNAs in cancer. Our strategy has the potential to address the current challenges in diagnosis, prognosis and staging of prostate cancer with a non- or minimally invasive approach.
Collapse
|
39
|
High-resolution NMR spectroscopy of human body fluids and tissues in relation to prostate cancer. NMR IN BIOMEDICINE 2014; 27:80-89. [PMID: 23828638 DOI: 10.1002/nbm.2979] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 05/02/2013] [Accepted: 05/02/2013] [Indexed: 06/02/2023]
Abstract
High-resolution NMR spectroscopic studies of prostate tissue extracts, prostatic fluid, seminal fluid, serum and urine can be used for the detection of prostate cancer, based on the differences in their metabolic profiles. Useful diagnostic information is obtained by the detection or quantification of as many metabolites as possible and comparison with normal samples. Only a few studies have shown the potential of high-resolution in vitro NMR of prostate tissues. A survey of the literature has revealed that studies on body fluids, such as urine and serum, in relation to prostate cancer are rare. In addition, the potential of NMR of nuclei other than (1)H, such as (13)C and (31)P, has not been exploited fully. The metabolomic analysis of metabolites, detected by high-resolution NMR, may help to identify metabolites which could serve as useful biomarkers for prostate cancer detection. Such NMR-derived biomarkers would not only help in prostate cancer detection and in understanding the in vivo MRS metabolic profile, but also to investigate the biochemical and metabolic changes associated with cancer. Here, we review the published research work on body fluids in relation to prostate and prostate tissue extracts, and highlight the potential of such studies for future work.
Collapse
|
40
|
Comparison of diagnostic accuracy between CellprepPlus® and ThinPrep® liquid-based preparations in effusion cytology. Diagn Cytopathol 2013; 42:384-90. [PMID: 24167083 DOI: 10.1002/dc.23041] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Accepted: 08/28/2013] [Indexed: 12/18/2022]
Abstract
Liquid-based cytology (LBC) is being increasingly used for body fluid specimens and has improved diagnostic accuracy when compared to conventional smears. We compared the diagnostic accuracy and cellular morphologic features between CellprepPlus® LBC and ThinPrep® LBC in effusion cytology. One hundred and eighty body fluid specimens, consisting of 119 pleural fluid specimens, 59 peritoneal fluid specimens, and 2 pericardial fluid specimens, were obtained from 166 patients. Equal volumes of body fluid from each specimen were used in the CellprepPlus® and ThinPrep® preparations. Sensitivity, specificity, and positive and negative predictive values were evaluated. In addition, we selected 16 specimens from patients with metastatic adenocarcinoma, confirmed them by both LBC preparations, and measured the size of the nucleus in the tumor cells in these specimens. The sensitivity of the CellprepPlus® and ThinPrep® methods was 73.1% and 50.0%, respectively. The specificity and positive predictive values were 100% for both LBC methods, and the negative predictive values of the CellprepPlus® and ThinPrep® methods were 90.9% and 83.3%, respectively. The average nuclear size of the tumor cells was calculated as 20.87 μm using the CellprepPlus® method and 15.08 μm using the ThinPrep® method (P < 0.05). The CellprepPlus® method provided better diagnostic accuracy of effusion cytology compared to the ThinPrep® method and revealed the characteristic morphological features of tumor cells, including large and hypochromatic nuclei, prominent nucleoli, distinct nuclear membranes, and high cellularity.
Collapse
|
41
|
Prioritization of biomarker targets in human umbilical cord blood: identification of proteins in infant blood serving as validated biomarkers in adults. ENVIRONMENTAL HEALTH PERSPECTIVES 2012; 120:764-769. [PMID: 22538116 PMCID: PMC3346780 DOI: 10.1289/ehp.1104190] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Accepted: 01/27/2012] [Indexed: 05/31/2023]
Abstract
BACKGROUND Early diagnosis represents one of the best lines of defense in the fight against a wide array of human diseases. Umbilical cord blood (UCB) is one of the first easily available diagnostic biofluids and can inform about the health status of newborns. However, compared with adult blood, its diagnostic potential remains largely untapped. OBJECTIVES Our goal was to accelerate biomarker research on UCB by exploring its detectable protein content and providing a priority list of potential biomarkers based on known proteins involved in disease pathways. METHODS We explored cord blood serum proteins by profiling a UCB pool of 12 neonates with different backgrounds using a combination of isoelectric focusing and liquid chromatography coupled with matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) and by comparing results with information contained in metabolic and disease databases available for adult blood. RESULTS A total of 1,210 UCB proteins were identified with a protein-level false discovery rate of ~ 5% as estimated by naïve target-decoy and MAYU approaches, signifying a 6-fold increase in the number of UCB proteins described to date. Identified proteins correspond to 138 different metabolic and disease pathways and provide a platform of mechanistically linked biomarker candidates for tracking disruptions in cellular processes. Moreover, among the identified proteins, 38 were found to be approved biomarkers for adult blood. CONCLUSIONS The results of this study advance current knowledge of the human cord blood serum proteome. They showcase the potential of UCB as a diagnostic medium for assessing infant health by detection and identification of candidate biomarkers for known disease pathways using a global, nontargeted approach. These biomarkers may inform about mechanisms of exposure-disease relationships. Furthermore, biomarkers approved by the U.S. Food and Drug Administration for screening in adult blood were detected in UCB and represent high-priority targets for immediate validation.
Collapse
|
42
|
In vitro Evaluation of Calcium Phosphate Precipitation on Possibly Bioactive Titanium Surfaces in the Presence of Laminin. J Oral Maxillofac Res 2011; 2:e3. [PMID: 24421995 PMCID: PMC3886075 DOI: 10.5037/jomr.2011.2303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2011] [Accepted: 07/19/2011] [Indexed: 11/30/2022]
Abstract
Objectives The aim of the present study was to evaluate calcium phosphate precipitation
and the amount of precipitated protein on three potentially bioactive
surfaces when adding laminin in simulated body fluid. Material and Methods Blasted titanium discs were prepared by three different techniques claimed to
provide bioactivity: alkali and heat treatment (AH), anodic oxidation (AO)
or hydroxyapatite coating (HA). A blasted surface incubated in
laminin-containing simulated body fuid served as a positive control (B)
while a blasted surface incubated in non laminin-containing simulated body
fuid served as a negative control (B-). The immersion time was 1 hour, 24
hours, 72 hours and 1 week. Surface topography was investigated by
interferometry and morphology by Scanning Electron Microscopy (SEM).
Analysis of the precipitated calcium and phosphorous was performed by Energy
Dispersive X-ray Spectroscopy (EDX) and the adsorbed laminin was quantified
by iodine (125I) labeling. Results SEM demonstrated that all specimens except for the negative control were
totally covered with calcium phosphate (CaP) after 1 week. EDX revealed that
B- demonstrated lower sum of Ca and P levels compared to the other groups
after 1 week. Iodine labeling demonstrated that laminin precipitated in a
similar manner on the possibly bioactive surfaces as on the positive control
surface. Conclusions Our results indicate that laminin precipitates equally on all tested titanium
surfaces and may function as a nucleation center thus locally elevating the
calcium concentration. Nevertheless further studies are required to clarify
the role of laminin in the interaction of biomaterials with the host bone
tissue.
Collapse
|
43
|
Identification of pancreas-specific proteins in endoscopically (endoscopic pancreatic function test) collected pancreatic fluid with liquid chromatography--tandem mass spectrometry. Pancreas 2010; 39:889-96. [PMID: 20182389 PMCID: PMC2891328 DOI: 10.1097/mpa.0b013e3181cf16f4] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVES We aimed to establish the endoscopic pancreatic function test (ePFT) as a method that can safely obtain pancreatic fluid for mass spectrometric analysis from patients during upper endoscopy and to reproducibly identify pancreas-specific proteins. METHODS We performed a sodium dodecyl sulfate-polyacrylamide gel electrophoresis and mass spectrometry-based proteomic analysis (in-gel tryptic digestion followed by liquid chromatography-tandem mass spectrometry [GeLC-MS/MS]) on ePFT-collected pancreatic fluid from 3 individuals, without evidence of chronic pancreatitis, who were undergoing an upper endoscopy for dyspepsia and chronic abdominal pain. RESULTS Pancreatic fluid was safely collected from all subjects. The sodium dodecyl sulfate-polyacrylamide gel electrophoretic analysis of ePFT-collected pancreatic fluid revealed no significant variation (F statistic, 1.33, P = 0.29) in protein concentration during the 1-hour collection period and a visually reproducible protein banding pattern among the 3 subjects. The GeLC-MS/MS analysis of ePFT-collected fluid identified pancreas-specific proteins previously described from endoscopic retrograde cholangiopancreatography and surgical collection methods. Gene ontology further revealed that most of the proteins identified have a molecular function of proteases. CONCLUSIONS The ePFT is capable of collecting large amounts of pancreatic fluid for proteomic analysis enabling the identification of pancreas-specific proteins. This endoscopic collection method coupled with GeLC-MS/MS is a powerful technique, which can be used in future investigations to elucidate pathways involved in the development and progression of pancreatic disease.
Collapse
|
44
|
Modeling alcohol's effects on organs in animal models. ALCOHOL RESEARCH & HEALTH : THE JOURNAL OF THE NATIONAL INSTITUTE ON ALCOHOL ABUSE AND ALCOHOLISM 2000; 24:93-104. [PMID: 11199283 PMCID: PMC6713009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Researchers have developed numerous animal models to investigate the development of various alcohol-related diseases. Such models have provided insights into the mechanism through which alcohol can induce liver damage. Animal models also have helped researchers explore the mechanisms by which both short-term (e.g., binge) and long-term drinking can interfere with the function of the heart, a condition referred to as alcoholic cardiomyopathy. Furthermore, animal models have provided substantial information on the causes of fetal alcohol syndrome. Such models have demonstrated that exposure to alcohol during gestation can lead to prenatal and postnatal growth retardation, characteristic facial malformations, immune system deficiencies, and alterations in the central nervous system.
Collapse
|
45
|
Alcohol's impact on kidney function. Alcohol Health Res World 1997; 21:84-92. [PMID: 15706766 PMCID: PMC6826793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Both acute and chronic alcohol consumption can compromise kidney function, particularly in conjunction with established liver disease. Investigators have observed alcohol-related changes in the structure and function of the kidneys and impairment in their ability to regulate the volume and composition of fluid and electrolytes in the body. Chronic alcoholic patients may experience low blood concentrations of key electrolytes as well as potentially severe alterations in the body's acid-base balance. In addition, alcohol can disrupt the hormonal control mechanisms that govern kidney function. By promoting liver disease, chronic drinking has further detrimental effects on the kidneys, including impaired sodium and fluid handling and even acute kidney failure.
Collapse
|