1
|
Catalysis of Indium Ion Electroreduction in the Presence of Acetazolamide in Chlorates(VII) Solutions with Varied Water Activity. Chemphyschem 2024; 25:e202300789. [PMID: 38363084 DOI: 10.1002/cphc.202300789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/31/2024] [Accepted: 02/13/2024] [Indexed: 02/17/2024]
Abstract
The influence of acetazolamide (ACT) on the kinetics and the mechanism of electroreduction of In(III) ions as a function of changes of the water activity was investigated using electrochemical methods (DC, SWV, CV and EIS, CV). The multi-step mechanism of the electroreduction process should take into account the dehydration step of indium ions and the presence of In-ACT (,,cap-pair" effect) active complexes, mediating electron transfer, located in the adsorption layer. Differences in the electrode mechanism in the presence of ACT were observed for higher chlorates(VII) concentrations (above 4 mol ⋅ dm-3 chlorates(VII)) reflected by a lack of step wise nature of the electrode process. The highest catalytic activity was observed in 4 mol ⋅ dm-3 chlorates(VII).
Collapse
|
2
|
Five years of advances in electrochemical analysis of protein biomarkers in lung cancer: a systematic review. Front Chem 2024; 12:1390050. [PMID: 38764920 PMCID: PMC11099832 DOI: 10.3389/fchem.2024.1390050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 04/01/2024] [Indexed: 05/21/2024] Open
Abstract
Lung cancer is the leading cause of cancer death in both men and women. It represents a public health problem that must be addressed through the early detection of specific biomarkers and effective treatment. To address this critical issue, it is imperative to implement effective methodologies for specific biomarker detection of lung cancer in real clinical samples. Electrochemical methods, including microfluidic devices and biosensors, can obtain robust results that reduce time, cost, and assay complexity. This comprehensive review will explore specific studies, methodologies, and detection limits and contribute to the depth of the discussion, making it a valuable resource for researchers and clinicians interested in lung cancer diagnosis.
Collapse
|
3
|
Electrochemical Methods for the Analysis of Trace Tin Concentrations-Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:7545. [PMID: 38138688 PMCID: PMC10744537 DOI: 10.3390/ma16247545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 12/24/2023]
Abstract
Tin determination allows for the monitoring of pollution and assessment of the impact of human activities on the environment. The determination of tin in the environment is crucial for the protection of human health and ecosystems, and for maintaining sustainability. Tin can be released into the environment from various sources, such as industry, transportation, and electronic waste. The concentration of tin in the environment can be determined by different analytical methods, depending on the form of tin present and the purpose of the analysis. The choice of an appropriate method depends on the type of sample, concentration levels, and the available instrumentation. In this paper, we have carried out a literature review of electrochemical methods for the determination of tin. Electrochemical methods of analysis such as polarography, voltammetry, and potentiometry can be used for the determination of tin in various environmental samples, as well as in metal alloys. The detection limits and linearity ranges obtained for the determination of tin by different electrochemical techniques are collected and presented. The influence of the choice of base electrolyte and working electrode on signals is also presented. Practical applications of the developed tin determination methods in analyzing real samples are also summarized.
Collapse
|
4
|
Analytical Methods for the Determination of Quercetin and Quercetin Glycosides in Pharmaceuticals and Biological Samples. Crit Rev Anal Chem 2023:1-26. [PMID: 37898879 DOI: 10.1080/10408347.2023.2269421] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
Flavonoids are plant-derived compounds that have several health benefits, including antioxidative, anti-inflammatory, anti-mutagenic, and anti-carcinogenic effects. Quercetin is a flavonoid that is widely present in various fruits, vegetables, and drinks. Accurate determination of quercetin in different samples is of great importance for its potential health benefits. This review, is an overview of sample preparation and determination methods for quercetin in diverse matrices. Previous research on sample preparation and determination methods for quercetin are summarized, highlighting the advantages and disadvantages of each method and providing insights into recent developments in quercetin sample treatment. Various analytical techniques are discussed including spectroscopic, chromatographic, electrophoretic, and electrochemical methods for the determination of quercetin and its derivatives in different samples. UV-Vis (Ultraviolet-visible) spectrophotometry is simple and inexpensive but lacks selectivity. Chromatographic techniques (HPLC, GC) offer selectivity and sensitivity, while electrophoretic and electrochemical methods provide high resolution and low detection limits, respectively. The aim of this review is to comprehensively explore the determination methods for quercetin and quercetin glycosides in diverse matrices, with emphasis on pharmaceutical and biological samples. The review also provides a theoretical basis for method development and application for the analysis of quercetin and quercetin glycosides in real samples.
Collapse
|
5
|
A Review of Electrochemical Techniques for Corrosion Monitoring - Fundamentals and Research Updates. Crit Rev Anal Chem 2023:1-26. [PMID: 37878408 DOI: 10.1080/10408347.2023.2267671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
Interculturally, corrosion has been counted as one of the most expensive factors toward the retrogression of concrete and metallic structures resulting in huge monetary losses and unanticipated loss of life. To a large extent, corrosion-related catastrophes can be avoided by having the ability to monitor corrosion before structural integrity is jeopardized. This paper critically reviews the various accustomed electrochemical techniques utilized for corrosion monitoring in terms of their definition, timeline, experimental set-up, advantages, and shortcomings. Additionally, literature exploiting these techniques as their corrosion detection technique has been focused on here. Furthermore, a comparison between recently reported methods has been made to provide better insights into the research progress in this arena.
Collapse
|
6
|
Analytical Methodologies for the Estimation of Oxazolidinone Antibiotics as Key Members of anti-MRSA Arsenal: A Decade in Review. Crit Rev Anal Chem 2023:1-30. [PMID: 37378883 DOI: 10.1080/10408347.2023.2228902] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2023]
Abstract
Gram-positive bacterial infections are among the most serious diseases related with high mortality rates and huge healthcare costs especially with the rise of antibiotic-resistant strains that limits treatment options. Thus, development of new antibiotics combating these multi-drug resistant bacteria is crucial. Oxazolidinone antibiotics are the only totally synthetic group of antibiotics that showed activity against multi-drug resistant Gram positive bacteria including MRSA because of their unique mechanism of action in targeting protein synthesis. This group include approved marketed members (tedizolid, linezolid and contezolid) or those under development (delpazlolid, radezolid and sutezolid). Due to the significant impact of this class, larger number of analytical methods were required to meet the needs of both clinical and industrial studies. Analyzing these drugs either alone or with other antimicrobial agents commonly used in ICU, in the presence of pharmaceutical or endogenous biological interferences, or in the presence of matrix impurities as metabolites and degradation products poses a big analytical challenge. This review highlights current analytical approaches published in the last decade (2012-2022) that dealt with the determination of these drugs in different matrices and discusses their advantages and disadvantages. Various techniques have been described for their determination including chromatographic, spectroscopic, capillary electrophoretic and electroanalytical methods. The review comprises six sections (one for each drug) with their related tables that depict critical figures of merit and some experimental conditions for the reviewed methods. Furthermore, future perspectives about the analytical methodologies that can be developed in the near future for determination of these drugs are suggested.
Collapse
|
7
|
Electrochemistry in a Two- or Three-Electrode Configuration to Understand Monopolar or Bipolar Configurations of Platinum Bionic Implants. MICROMACHINES 2023; 14:722. [PMID: 37420955 DOI: 10.3390/mi14040722] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/21/2023] [Accepted: 03/22/2023] [Indexed: 07/09/2023]
Abstract
Electrodes are used in vivo for chemical sensing, electrophysiological recording, and stimulation of tissue. The electrode configuration used in vivo is often optimised for a specific anatomy and biological or clinical outcomes, not electrochemical performance. Electrode materials and geometries are constrained by biostability and biocompatibility issues and may be required to function clinically for decades. We performed benchtop electrochemistry, with changes in reference electrode, smaller counter-electrode sizes, and three- or two-electrode configurations. We detail the effects different electrode configurations have on typical electroanalytical techniques used on implanted electrodes. Changes in reference electrode required correction by application of an offset potential. In a two-electrode configuration with similar working and reference/counter-electrode sizes, the electrochemical response was dictated by the rate-limiting charge transfer step at either electrode. This could invalidate calibration curves, standard analytical methods, and equations, and prevent use of commercial simulation software. We provide methods for determining if an electrode configuration is affecting the in vivo electrochemical response. We recommend sufficient details be provided in experimental sections on electronics, electrode configuration, and their calibration to justify results and discussion. In conclusion, the experimental limitations of performing in vivo electrochemistry may dictate what types of measurements and analyses are possible, such as obtaining relative rather than absolute measurements.
Collapse
|
8
|
Electrochemical and Bioelectrochemical Sensing Platforms for Diagnostics of COVID-19. BIOSENSORS 2023; 13:336. [PMID: 36979548 PMCID: PMC10046778 DOI: 10.3390/bios13030336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 02/15/2023] [Accepted: 02/27/2023] [Indexed: 06/18/2023]
Abstract
Rapid transmission and high mortality rates caused by the SARS-CoV-2 virus showed that the best way to fight against the pandemic was through rapid, accurate diagnosis in parallel with vaccination. In this context, several research groups around the world have endeavored to develop new diagnostic methods due to the disadvantages of the gold standard method, reverse transcriptase polymerase chain reaction (RT-PCR), in terms of cost and time consumption. Electrochemical and bioelectrochemical platforms have been important tools for overcoming the limitations of conventional diagnostic platforms, including accuracy, accessibility, portability, and response time. In this review, we report on several electrochemical sensors and biosensors developed for SARS-CoV-2 detection, presenting the concepts, fabrication, advantages, and disadvantages of the different approaches. The focus is devoted to highlighting the recent progress of electrochemical devices developed as next-generation field-deployable analytical tools as well as guiding future researchers in the manufacture of devices for disease diagnosis.
Collapse
|
9
|
Electrochemical Characterization of the Antioxidant Properties of Medicinal Plants and Products: A Review. Molecules 2023; 28:molecules28052308. [PMID: 36903553 PMCID: PMC10004803 DOI: 10.3390/molecules28052308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/19/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Medicinal plants are an important source of bioactive compounds with a wide spectrum of practically useful properties. Various types of antioxidants synthesized in plants are the reasons for their application in medicine, phytotherapy, and aromatherapy. Therefore, reliable, simple, cost-effective, eco-friendly, and rapid methods for the evaluation of antioxidant properties of medicinal plants and products on their basis are required. Electrochemical methods based on electron transfer reactions are promising tools to solve this problem. Total antioxidant parameters and individual antioxidant quantification can be achieved using suitable electrochemical techniques. The analytical capabilities of constant-current coulometry, potentiometry, various types of voltammetry, and chrono methods in the evaluation of total antioxidant parameters of medicinal plants and plant-derived products are presented. The advantages and limitations of methods in comparison to each other and traditional spectroscopic methods are discussed. The possibility to use electrochemical detection of the antioxidants via reactions with oxidants or radicals (N- and O-centered) in solution, with stable radicals immobilized on the electrode surface, via oxidation of antioxidants on a suitable electrode, allows the study of various mechanisms of antioxidant actions occurring in living systems. Attention is also paid to the individual or simultaneous electrochemical determination of antioxidants in medicinal plants using chemically modified electrodes.
Collapse
|
10
|
Developing Improved Corrosion-Resistant AA5083-BN/WC Composites for Tribological Applications. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1663. [PMID: 36837290 PMCID: PMC9967476 DOI: 10.3390/ma16041663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 01/31/2023] [Accepted: 02/14/2023] [Indexed: 06/18/2023]
Abstract
In this study, corrosion-resistant AA5083-BN/WC composites were developed for tribological applications through adequate control of the reinforcement content (WC and BN) in the matrix (AA5083 alloy). The effects of 6% and 12% tungsten carbide (WC) as well as 6% and 12% boron nitride (BN) additions on the corrosion behavior of AA5083 aluminum composite in 3.5% NaCl solution were carried out. Electrochemical techniques such as cyclic potentiodynamic polarization (CPP), changes in the chronoamperometric current with time (CCT), and electrochemical impedance spectroscopy (EIS) were utilized. The polarization results showed that the addition of 6% WC to the AA5083 alloy matrix improved its resistance to corrosion (RP). Rp exhibited an additional increase by adding 12% WC to the matrix. The values of RP were observed to increase for the AA5083 composite when adding 6% BN, and the highest RP values were recorded for the composite that contains 12% BN. The results obtained by the CPP method were confirmed by CCT and EIS measurements, where the presence of WC and BN protected the developed AA5083- BN/WC composites against corrosion. The corrosion resistance revealed an additional improvement with an increase in WC and BN content from 6% to 12%. The results also confirm that pitting corrosion decreased in the presence of WC and BN in the fabricated composites.
Collapse
|
11
|
Cold-Sprayed Composite Metal-Fluoropolymer Coatings for Alloy Protection against Corrosion and Wear. MATERIALS (BASEL, SWITZERLAND) 2023; 16:918. [PMID: 36769923 PMCID: PMC9918237 DOI: 10.3390/ma16030918] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/13/2023] [Accepted: 01/14/2023] [Indexed: 06/18/2023]
Abstract
Results of studying the properties of composite fluoropolymer-containing coatings formed by the cold spray (CS) method on the surface of constructional steel are presented. Different ways of protective coating formation are proposed. The composition of coatings was studied using SEM/EDX analysis. The incorporation of super-dispersed polytetrafluoroethylene (SPTFE) into the coating increases the corrosion resistance of the copper-zinc-based cold-sprayed coating. Analysis of the electrochemical properties obtained using EIS (electrochemical impedance spectroscopy) and PDP (potentiodynamic polarization) indicates that samples treated with SPTFE on a base copper-zinc coating showed lower corrosion current density and higher impedance modulus (jc = 8.5 × 10-7 A cm-2, |Z|f=0.1 Hz = 5.3 × 104 Ω∙cm2) than the specimen with cold-sprayed SPTFE (jc = 6.1 × 10-6 A cm-2, |Z|f=0.1 Hz = 8.1 × 103 Ω∙cm2). The best anticorrosion properties were revealed for the sample with a cold-sprayed base Cu-Zn layer annealed at 500 °C for 1 h, followed by SPTFE friction treatment and re-annealed at 350 °C for 1 h. The corrosion current density jc of such a coating is 25 times lower than that for the base Cu-Zn coating. The antifriction properties and hydrophobicity of the formed layers are described. Obtained results indicate that cold-sprayed polymer-containing coatings effectively improve the corrosion and wear resistivity of the treated material.
Collapse
|
12
|
Use of metal nanoparticles for preconcentration and analysis of biological thiols. Electrophoresis 2023; 44:135-157. [PMID: 35892259 DOI: 10.1002/elps.202200142] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 07/11/2022] [Accepted: 07/19/2022] [Indexed: 02/01/2023]
Abstract
Metal nanoparticles (NPs) exhibit several unique physicochemical properties, including redox activity, surface plasmon resonance, ability to quench fluorescence, biocompatibility, or a high surface-to-volume ratio. They are being increasingly used in analysis and preconcentration of thiol containing compounds, because they are able to spontaneously form a stable Au/Ag/Cu-S dative bond. They thus find wide application in environmental and particularly in medical science, especially in the analysis of biological thiols, the endogenous compounds that play a significant role in many biological systems. In this review article, we provide an overview of various types of NPs that have been applied in analysis and preconcentration of biological thiols, mainly in human biological fluids. We first discuss shortly the types of NPs and their synthesis, properties, and their ability to interact with thiol compounds. Then we outline the sample preconcentration and analysis methods that were used for this purpose with special emphasis on optical, electrochemical, and separation techniques.
Collapse
|
13
|
Role of Silver Nanoparticle-Doped 2-Aminodiphenylamine Polymeric Material in the Detection of Dopamine (DA) with Uric Acid Interference. MATERIALS 2022; 15:ma15041308. [PMID: 35207848 PMCID: PMC8875575 DOI: 10.3390/ma15041308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/03/2022] [Accepted: 02/08/2022] [Indexed: 02/01/2023]
Abstract
A viable electrochemical approach for the detection of dopamine (DA) in uric acid (UA) utilizing a silver nanoparticle-doped 2-aminodiphenylamine (AgNPs-2ADPA) electrode was invented. The electrochemical performance of DA showed that the incorporated electrode displayed outstanding electrocatalytic performance to the electrochemical oxidation of DA. In our study, the AgNPs-2ADPA exhibits remarkable catalytic activity, retaining high current value and resilience when employed as a working electrode component for electrocatalytic detection of DA. We have also utilized the bare and polymeric-2ADPA in DA detection for a comparison study. This method offers a facile route with extraordinary sensitivity, selectivity, and strength for the voltammetric detection of DA, even in the presence of UA and ascorbic acid (AA) as interferents, that can be employed for pharmaceutical and biological specimens.
Collapse
|
14
|
Advances in Design Strategies of Multiplex Electrochemical Aptasensors. SENSORS (BASEL, SWITZERLAND) 2021; 22:s22010161. [PMID: 35009703 PMCID: PMC8749765 DOI: 10.3390/s22010161] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/23/2021] [Accepted: 12/24/2021] [Indexed: 05/08/2023]
Abstract
In recent years, the need for simple, fast, and economical detection of food and environmental contaminants, and the necessity to monitor biomarkers of different diseases have considerably accelerated the development of biosensor technology. However, designing biosensors capable of simultaneous determination of two or more analytes in a single measurement, for example on a single working electrode in single solution, is still a great challenge. On the other hand, such analysis offers many advantages compared to single analyte tests, such as cost per test, labor, throughput, and convenience. Because of the high sensitivity and scalability of the electrochemical detection systems on the one hand and the specificity of aptamers on the other, the electrochemical aptasensors are considered to be highly effective devices for simultaneous detection of multiple-target analytes. In this review, we describe and evaluate multi-label approaches based on (1) metal quantum dots and metal ions, (2) redox labels, and (3) enzyme labels. We focus on recently developed strategies for multiplex sensing using electrochemical aptasensors. Furthermore, we emphasize the use of different nanomaterials in the construction of these aptasensors. Based on examples from the existing literature, we highlight recent applications of multiplexed detection platforms in clinical diagnostics, food control, and environmental monitoring. Finally, we discuss the advantages and disadvantages of the aptasensors developed so far, and debate possible challenges and prospects.
Collapse
|
15
|
Disposable Paper-Based Biosensors for the Point-of-Care Detection of Hazardous Contaminations-A Review. BIOSENSORS 2021; 11:316. [PMID: 34562906 PMCID: PMC8464915 DOI: 10.3390/bios11090316] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 08/29/2021] [Accepted: 09/01/2021] [Indexed: 02/07/2023]
Abstract
The fast detection of trace amounts of hazardous contaminations can prevent serious damage to the environment. Paper-based sensors offer a new perspective on the world of analytical methods, overcoming previous limitations by fabricating a simple device with valuable benefits such as flexibility, biocompatibility, disposability, biodegradability, easy operation, large surface-to-volume ratio, and cost-effectiveness. Depending on the performance type, the device can be used to analyze the analyte in the liquid or vapor phase. For liquid samples, various structures (including a dipstick, as well as microfluidic and lateral flow) have been constructed. Paper-based 3D sensors are prepared by gluing and folding different layers of a piece of paper, being more user-friendly, due to the combination of several preparation methods, the integration of different sensor elements, and the connection between two methods of detection in a small set. Paper sensors can be used in chromatographic, electrochemical, and colorimetric processes, depending on the type of transducer. Additionally, in recent years, the applicability of these sensors has been investigated in various applications, such as food and water quality, environmental monitoring, disease diagnosis, and medical sciences. Here, we review the development (from 2010 to 2021) of paper methods in the field of the detection and determination of toxic substances.
Collapse
|
16
|
Scanning Electrochemical Impedance Microscopy in Redox-Competition Mode for the Investigation of Antibodies Labelled with Horseradish Peroxidase. MATERIALS 2021; 14:ma14154301. [PMID: 34361494 PMCID: PMC8348749 DOI: 10.3390/ma14154301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 11/25/2022]
Abstract
Scanning electrochemical microscopy enhanced by electrochemical impedance spectroscopy (SEIM) was applied to detect immobilized antibodies labelled with horseradish peroxidase (Ab-HRP). The localized HRP activity was investigated by the SEIM redox competition (RC-SEIM) mode using hydrogen peroxide as a substrate and hexacyanoferrate as a redox mediator. Electrochemical impedance shows to be related to the consumption of hydrogen peroxide at the ultramicroelectrode. For the evaluation of impedimetric results, an equivalent electric circuit was applied with solution resistance, double-layer capacitance, and charge-transfer resistance. These equivalent circuit characteristics depend on the distance between the sample and ultramicroelectrode, and the concentration of substrate. From the gathered data, the charge-transfer resistance appeared to be the parameter describing the behavior of HRP catalyzed reaction as it showed a linear dependence on H2O2 concentration. The RC-SEIM mode suitability for the studying of HRP catalyzed reactions and for the evaluation of Ab-HRP bound to the surface was demonstrated. Additionally, the applicability of RC-SEIM mode for the determination of Ab-HRP affinity bound to the target analyte was discussed.
Collapse
|
17
|
What Can Electrochemical Methods Offer in Determining DNA-Drug Interactions? Molecules 2021; 26:3478. [PMID: 34200473 PMCID: PMC8201389 DOI: 10.3390/molecules26113478] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 06/02/2021] [Accepted: 06/04/2021] [Indexed: 11/16/2022] Open
Abstract
The interactions of compounds with DNA have been studied since the recognition of the role of nucleic acid in organisms. The design of molecules which specifically interact with DNA sequences allows for the control of the gene expression. Determining the type and strength of such interaction is an indispensable element of pharmaceutical studies. Cognition of the therapeutic action mechanisms is particularly important for designing new drugs. Owing to their sensitivity, simplicity, and low costs, electrochemical methods are increasingly used for this type of research. Compared to other techniques, they require a small number of samples and are characterized by a high reliability. These methods can provide information about the type of interaction and the binding strength, as well as the damage caused by biologically active molecules targeting the cellular DNA. This review paper summarizes the various electrochemical approaches used for the study of the interactions between pharmaceuticals and DNA. The main focus is on the papers from the last decade, with particular attention on the voltammetric techniques. The most preferred experimental approaches, the electrode materials and the new methods of modification are presented. The data on the detection ranges, the binding modes and the binding constant values of pharmaceuticals are summarized. Both the importance of the presented research and the importance of future prospects are discussed.
Collapse
|
18
|
Molecular Imprinting Technology for Determination of Uric Acid. Int J Mol Sci 2021; 22:5032. [PMID: 34068596 PMCID: PMC8126139 DOI: 10.3390/ijms22095032] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/06/2021] [Accepted: 05/07/2021] [Indexed: 01/05/2023] Open
Abstract
The review focuses on the overview of electrochemical sensors based on molecularly imprinted polymers (MIPs) for the determination of uric acid. The importance of robust and precise determination of uric acid is highlighted, a short description of the principles of molecular imprinting technology is presented, and advantages over the others affinity-based analytical methods are discussed. The review is mainly concerned with the electro-analytical methods like cyclic voltammetry, electrochemical impedance spectroscopy, amperometry, etc. Moreover, there are some scattered notes to the other electrochemistry-related analytical methods, which are capable of providing additional information and to solve some challenges that are not achievable using standard electrochemical methods. The significance of these overviewed methods is highlighted. The overview of the research that is employing MIPs imprinted with uric acid is mainly targeted to address these topics: (i) type of polymers, which are used to design uric acid imprint structures; (ii) types of working electrodes and/or other parts of signal transducing systems applied for the registration of analytical signal; (iii) the description of the uric acid extraction procedures applied for the design of final MIP-structure; (iv) advantages and disadvantages of electrochemical methods and other signal transducing methods used for the registration of the analytical signal; (vi) overview of types of interfering molecules, which were analyzed to evaluate the selectivity; (vi) comparison of analytical characteristics such as linear range, limits of detection and quantification, reusability, reproducibility, repeatability, and stability. Some insights in future development of uric acid sensors are discussed in this review.
Collapse
|
19
|
Editorial: Advances in Analytical Features of Electrochemical Methods for the Analysis of Complicated Real Samples. Front Chem 2021; 9:648920. [PMID: 33816439 PMCID: PMC8010234 DOI: 10.3389/fchem.2021.648920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Accepted: 02/11/2021] [Indexed: 11/16/2022] Open
|
20
|
Frontiers and Challenges in Electrochemical Corrosion Monitoring; Surface and Downhole Applications. SENSORS 2020; 20:s20226583. [PMID: 33217977 PMCID: PMC7698726 DOI: 10.3390/s20226583] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 11/09/2020] [Accepted: 11/11/2020] [Indexed: 11/16/2022]
Abstract
Corrosion sensing is essential to monitor and safeguard the materials' health and control the maintenance cost of corrosion-prone materials used in various industries. The petroleum industry is a major sufferer of corrosion costs among various industries due to pipelines and downhole applications. This review article encompasses an overview of various technologies used in early detection stages for more reliable corrosion sensing and warnings. This review provides a summary of corrosion types, corrosion causing chemical species, different destructive and non-destructive technologies used in monitoring corrosion and a comprehensive overview of the state-of-the-art of various electrochemical techniques used for surface and downhole corrosion monitoring. Finally, the existing challenges for corrosion monitoring in surface and downhole conditions and prospects are discussed.
Collapse
|
21
|
Study of Antioxidant Properties of Agents from the Perspective of Their Action Mechanisms. Molecules 2020; 25:E4251. [PMID: 32947948 PMCID: PMC7570667 DOI: 10.3390/molecules25184251] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/13/2020] [Accepted: 09/15/2020] [Indexed: 11/16/2022] Open
Abstract
The creation and analysis of a large variety of existing methods for the evaluation of integrated antioxidant properties are quite relevant in connection with a range of biological mechanisms of the antioxidants (AO) action. In this work, the existing methods are correlated with mechanisms of antioxidant action. It is shown that the results obtained by various methods are mainly incomparable. This can be connected with the implementation of various mechanisms of antioxidant action in methods. The analysis of the literature data presented in this review indicates the difficulty of creating a universal method and the feasibility of using integrated approaches based on the use of several methods that implement and combine various mechanisms of the chemical conversion of antioxidants. This review describes methods for studying the chelating ability of antioxidants, except for methods based on electron and hydrogen atom transfer reactions, which are currently not widely covered in modern literature. With the description of each mechanism, special attention is paid to electrochemical methods, as the interaction of active oxygen metabolites of radical and non-radical nature with antioxidants has an electron/proton/donor-acceptor nature, which corresponds to the nature of electrochemical methods and suggests that they can be used to study the interaction.
Collapse
|
22
|
Emerging techniques for determining the quality and safety of tea products: A review. Compr Rev Food Sci Food Saf 2020; 19:2613-2638. [PMID: 33336976 DOI: 10.1111/1541-4337.12611] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 07/13/2020] [Accepted: 07/14/2020] [Indexed: 11/30/2022]
Abstract
Spectroscopic techniques, electrochemical methods, nanozymes, computer vision, and modified chromatographic techniques are the emerging techniques for determining the quality and safety parameters (e.g., physical, chemical, microbiological, and classified parameters, as well as inorganic and organic contaminants) of tea products (such as fresh tea leaves, commercial tea, tea beverage, tea powder, and tea bakery products) effectively. By simplifying the sample preparation, speeding up the detection process, reducing the interference of other substances contained in the sample, and improving the sensitivity and accuracy of the current standard techniques, the abovementioned emerging techniques achieve rapid, cost-effective, and nondestructive or slightly destructive determination of tea products, with some of them providing real-time detection results. Applying these emerging techniques in the whole industry of tea product processing, right from the picking of fresh tea leaves, fermentation of tea leaves, to the sensory evaluation of commercial tea, as well as developing portable devices for real-time and on-site determination of classified and safety parameters (e.g., the geographical origin, grade, and content of contaminants) will not only eliminate the strong dependence on professionals but also help mechanize the production of tea products, which deserves further research. Conducting a review on the application of spectroscopic techniques, electrochemical methods, nanozymes, computer vision, and modifications of chromatographic techniques for quality and safety determination of tea products may serve as guide for other types of foods and beverages, offering potential techniques for their detection and evaluation, which would promote the development of the food industry.
Collapse
|
23
|
Non-Enzymatic Glucose Sensing Based on Incorporation of Carbon Nanotube into Zn-Co-S Ball-in-Ball Hollow Sphere. SENSORS 2020; 20:s20154340. [PMID: 32759678 PMCID: PMC7436182 DOI: 10.3390/s20154340] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/30/2020] [Accepted: 08/01/2020] [Indexed: 11/16/2022]
Abstract
Zn-Co-S ball-in-ball hollow sphere (BHS) was successfully prepared by solvothermal sulfurization method. An efficient strategy to synthesize Zn-Co-S BHS consisted of multilevel structures by controlling the ionic exchange reaction was applied to obtain great performance electrode material. Carbon nanotubes (CNTs) as a conductive agent were uniformly introduced with Zn-Co-S BHS to form Zn-Co-S BHS/CNTs and expedited the considerable electrocatalytic behavior toward glucose electro-oxidation in alkaline medium. In this study, characterization with scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) was used for investigating the morphological and physical/chemical properties and further evaluating the feasibility of Zn-Co-S BHS/CNTs in non-enzymatic glucose sensing. Electrochemical methods (cyclic voltammetry (CV) and chronoamperometry (CA)) were performed to investigate the glucose sensing performance of Zn-Co-S BHS/CNTs. The synergistic effect of Faradaic redox couple species of Zn-Co-S BHS and unique conductive network of CNTs exhibited excellent electrochemical catalytic ability towards the glucose electro-oxidation, which revealed linear range from 5 to 100 μM with high sensitivity of 2734.4 μA mM-1 cm-2, excellent detection limit of 2.98 μM, and great selectivity in the presence of dopamine, uric acid, ascorbic acid, and fructose. Thus, Zn-Co-S BHS/CNTs would be expected to be a promising material for non-enzymatic glucose sensing.
Collapse
|
24
|
Electrochemical Methods for Lithium Recovery: A Comprehensive and Critical Review. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e1905440. [PMID: 32307755 DOI: 10.1002/adma.201905440] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 01/22/2020] [Accepted: 02/13/2020] [Indexed: 06/11/2023]
Abstract
Due to the ubiquitous presence of lithium-ion batteries in portable applications, and their implementation in the transportation and large-scale energy sectors, the future cost and availability of lithium is currently under debate. Lithium demand is expected to grow in the near future, up to 900 ktons per year in 2025. Lithium utilization would depend on a strong increase in production. However, the currently most extended lithium extraction method, the lime-soda evaporation process, requires a period of time in the range of 1-2 years and depends on weather conditions. The actual global production of lithium by this technology will soon be far exceeded by market demand. Alternative production methods have recently attracted great attention. Among them, electrochemical lithium recovery, based on electrochemical ion-pumping technology, offers higher capacity production, it does not require the use of chemicals for the regeneration of the materials, reduces the consumption of water and the production of chemical wastes, and allows the production rate to be controlled, attending to the market demand. Here, this technology is analyzed with a special focus on the methodology, materials employed, and reactor designs. The state-of-the-art is reevaluated from a critical perspective and the viability of the different proposed methodologies analyzed.
Collapse
|
25
|
High-Performance Nucleic Acid Sensors for Liquid Biopsy Applications. Angew Chem Int Ed Engl 2019; 59:2554-2564. [PMID: 31332937 DOI: 10.1002/anie.201905005] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 07/21/2019] [Indexed: 12/18/2022]
Abstract
Circulating tumour nucleic acids (ctNAs) are released from tumours cells and can be detected in blood samples, providing a way to track tumors without requiring a tissue sample. This "liquid biopsy" approach has the potential to replace invasive, painful, and costly tissue biopsies in cancer diagnosis and management. However, a very sensitive and specific approach is required to detect relatively low amounts of mutant sequences linked to cancer because they are masked by the high levels of wild-type sequences. This review discusses high-performance nucleic acid biosensors for ctNA analysis in patient samples. We compare sequencing- and amplification-based methods to next-generation sensors for ctDNA and ctRNA (including microRNA) profiling, such as electrochemical methods, surface plasmon resonance, Raman spectroscopy, and microfluidics and dielectrophoresis-based assays. We present an overview of the analytical sensitivity and accuracy of these methods as well as the biological and technical challenges they present.
Collapse
|
26
|
A Recent Progress of Steel Bar Corrosion Diagnostic Techniques in RC Structures. SENSORS 2018; 19:s19010034. [PMID: 30583463 PMCID: PMC6339003 DOI: 10.3390/s19010034] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 12/11/2018] [Accepted: 12/17/2018] [Indexed: 11/28/2022]
Abstract
Corrosion of steel bar is one of key factors undermining reinforced concrete (RC) structures in a harsh environment. This paper attempts to review the non-destructive procedures from the aspect of the corrosion measurement techniques, especially their advantages and limitations. Systematical classification of diagnostic methods is carried out to determine any probable corrosion issues before the structures become severe, and helps choose the suitable method according to different construction features. Furthermore, the three electrochemical factors method is introduced to inspire researchers to combine various techniques to improve corrosion evaluation accuracy. The recommendations for future work are summarized, in conclusion.
Collapse
|
27
|
Abstract
Microbial biofilms, which are elaborate and highly resistant microbial aggregates formed on surfaces or medical devices, cause two-thirds of infections and constitute a serious threat to public health. Immunocompromised patients, individuals who require implanted devices, artificial limbs, organ transplants, or external life support and those with major injuries or burns, are particularly prone to become infected. Antibiotics, the mainstay treatments of bacterial infections, have often proven ineffective in the fight against microbes when growing as biofilms, and to date, no antibiotic has been developed for use against biofilm infections. Antibiotic resistance is rising, but biofilm-mediated multidrug resistance transcends this in being adaptive and broad spectrum and dependent on the biofilm growth state of organisms. Therefore, the treatment of biofilms requires drug developers to start thinking outside the constricted "antibiotics" box and to find alternative ways to target biofilm infections. Here, we highlight recent approaches for combating biofilms focusing on the eradication of preformed biofilms, including electrochemical methods, promising antibiofilm compounds and the recent progress in drug delivery strategies to enhance the bioavailability and potency of antibiofilm agents.
Collapse
|
28
|
Synergistic Effect of Superhydrophobicity and Oxidized Layers on Corrosion Resistance of Aluminum Alloy Surface Textured by Nanosecond Laser Treatment. ACS APPLIED MATERIALS & INTERFACES 2015; 7:19500-8. [PMID: 26271017 DOI: 10.1021/acsami.5b06217] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We report a new efficient method for fabricating a superhydrophobic oxidized surface of aluminum alloys with enhanced resistance to pitting corrosion in sodium chloride solutions. The developed coatings are considered very prospective materials for the automotive industry, shipbuilding, aviation, construction, and medicine. The method is based on nanosecond laser treatment of the surface followed by chemisorption of a hydrophobic agent to achieve the superhydrophobic state of the alloy surface. We have shown that the surface texturing used to fabricate multimodal roughness of the surface may be simultaneously used for modifying the physicochemical properties of the thick surface layer of the substrate itself. Electrochemical and wetting experiments demonstrated that the superhydrophobic state of the metal surface inhibits corrosion processes in chloride solutions for a few days. However, during long-term contact of a superhydrophobic coating with a solution, the wetted area of the coating is subjected to corrosion processes due to the formation of defects. In contrast, the combination of an oxide layer with good barrier properties and the superhydrophobic state of the coating provides remarkable corrosion resistance. The mechanisms for enhancing corrosion protective properties are discussed.
Collapse
|
29
|
The effects of three commonly used extraction methods on the redox properties of extracellular polymeric substances from activated sludge. ENVIRONMENTAL TECHNOLOGY 2015; 36:2884-2891. [PMID: 26027459 DOI: 10.1080/09593330.2015.1051590] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Accepted: 05/12/2015] [Indexed: 06/04/2023]
Abstract
Recently, the redox properties of extracellular polymeric substances (EPS) have attracted the attention of scientists due to their associated environmental significance, such as organic pollutant (e.g. nitroaromatics and substituted nitrobenzenes) degradation and heavy metal (e.g. Cr(VI) and U(VI)) detoxification. Although the separation of EPS from bacterial cells is more often the first step in studies on EPS, and studies have demonstrated that extraction procedures can influence the sorption properties of EPS, few attempts have been made to investigate how separation methods affect the redox properties of the obtained EPS. In this study, three common extraction approaches, that is, centrifugation, formaldehyde+NaOH and ethylene diamine tetra-acetic acid (EDTA), were employed to extract EPS from activated sludge, and the obtained EPS were evaluated for their redox properties using electrochemical means, including cyclic voltammetry and chronoamperometry. In addition, spectroscopic techniques were utilized to explore the structural characteristics and composition of EPS. The results indicated that EPS extracted by EDTA clearly displayed reversible oxidation-reduction peaks in cyclic voltammograms and significantly higher electron-accepting capacity compared with EPS extracted using the other two approaches. Fourier transform infrared spectra and three-dimensional excitation-emission matrix spectra suggested that the EPS extracted with EDTA presented better redox properties because of the effective and efficient extraction of the humic substances, which are important components of the EPS of activated sludge. Therefore, extraction method has an impact on the composition and redox properties of EPS and should be chosen according to research purpose and EPS source.
Collapse
|
30
|
Abstract
Carbon nanoelectrodes with tip diameters ranging from tens to hundreds of nanometers are fabricated by pyrolitic deposition of carbon films along the entire inner surfaces of pulled-glass pipettes. The pulled end of each glass pipette is then etched to expose a desired length (typically, a few micrometers) of carbon pipe. The carbon film provides an electrically conductive path from the nanoscopic carbon tip to the distal, macroscopic end of the pipette, bridging between the nanoscale tip and the macroscale handle, without a need for assembly. We used our nanoelectrodes to penetrate into individual cells and cell nuclei and measured the variations in the electrode impedance upon cell and nucleus penetration as well as the electrode impedance as a function of cell penetration depth. Theoretical predictions based on a simple circuit model were in good agreement with experimental data.
Collapse
|
31
|
Materials and fractal designs for 3D multifunctional integumentary membranes with capabilities in cardiac electrotherapy. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2015; 27:1731-7. [PMID: 25641076 PMCID: PMC4527319 DOI: 10.1002/adma.201405017] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2014] [Revised: 11/26/2014] [Indexed: 05/20/2023]
Abstract
Advanced materials and fractal design concepts form the basis of a 3D conformal electronic platform with unique capabilities in cardiac electrotherapies. Fractal geometries, advanced electrode materials, and thin, elastomeric membranes yield a class of device capable of integration with the entire 3D surface of the heart, with unique operational capabilities in low power defibrillation. Co-integrated collections of sensors allow simultaneous monitoring of physiological responses. Animal experiments on Langendorff-perfused rabbit hearts demonstrate the key features of these systems.
Collapse
|
32
|
Direct delamination of graphene for high-performance plastic electronics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2014; 10:694-8. [PMID: 24106080 DOI: 10.1002/smll.201301892] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 08/03/2013] [Indexed: 05/17/2023]
Abstract
Electrochemical delamination is developed to transfer graphene for plastic electronics. The use of a sacrificial support during transfer is eliminated by depositing the target polyimide substrate directly onto graphene. A continuous and residue-free graphene surface with less line disruptions (such as ripples and wrinkles) is obtained on the target polyimide substrate, and good mechanical durability as well as low sheet resistance is obtained. The properties are competitive with conventional transparent conducting films.
Collapse
|
33
|
Rapid release of plasmid DNA from surfaces coated with polyelectrolyte multilayers promoted by the application of electrochemical potentials. ACS APPLIED MATERIALS & INTERFACES 2012; 4:2726-34. [PMID: 22551230 PMCID: PMC3359390 DOI: 10.1021/am3003632] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We report an approach to the rapid release of DNA based on the application of electrochemical potentials to surfaces coated with polyelectrolyte-based thin films. We fabricated multilayered polyelectrolyte films (or "polyelectrolyte multilayers", PEMs) using plasmid DNA and a model hydrolytically degradable cationic poly(β-amino ester) (polymer 1) on stainless steel substrates using a layer-by-layer approach. The application of continuous reduction potentials in the range of -1.1 to -0.7 V (vs a Ag/AgCl electrode) to film-coated electrodes in PBS at 37 °C resulted in the complete release of DNA over a period of 1-2 min. Film-coated electrodes incubated under identical conditions in the absence of applied potentials required 1-2 days for complete release. Control over the magnitude of the applied potential provided control over the rate at which DNA was released. The results of these and additional physical characterization experiments are consistent with a mechanism of film disruption that is promoted by local increases in pH at the film/electrode interface (resulting from electrochemical reduction of water or dissolved oxygen) that disrupt ionic interactions in these materials. The results of cell-based experiments demonstrated that DNA was released in a form that remains intact and able to promote transgene expression in mammalian cells. Finally, we demonstrate that short-term (i.e., non-continuous) electrochemical treatments can also be used to promote faster film erosion (e.g., over 1-2 h) once the potential is removed. Past studies demonstrate that PEMs fabricated using polymer 1 can promote surface-mediated transfection of cells and tissues in vitro and in vivo. With further development, the electrochemical approaches reported here could thus provide new methods for the rapid, triggered, or spatially patterned transfer of DNA (or other agents) from surfaces of interest in a variety of fundamental and applied contexts.
Collapse
|