1
|
User Performance Evaluation and System Accuracy Assessment of Four Blood Glucose Monitoring Systems With Color Coding of Measurement Results. J Diabetes Sci Technol 2024; 18:644-652. [PMID: 36433806 PMCID: PMC11089863 DOI: 10.1177/19322968221141926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Blood glucose monitoring systems (BGMSs) are a cornerstone in diabetes management. They have to provide sufficiently accurate results in the hands of lay users, particularly in insulin-treated patients. The aim of this study was user performance evaluation and system accuracy assessment of four BGMSs with color coding of results. METHODS Study procedures were based on ISO 15197:2013. User performance evaluation included data from 100 participants, each of whom used every system with one reagent lot. Study personnel observed user techniques. For the system accuracy assessment, 100 capillary samples were obtained for measurement in duplicate with each of three reagent system lots per system, resulting in 600 results per system. RESULTS All assessed BGMSs exhibited a sufficient level of accuracy, with small differences between them. In the user performance evaluation, study personnel observed the smallest total number of user errors with Contour Next (Ascensia), followed by Accu-Chek Instant (Roche), Medisafe Fit Smile (Terumo), and OneTouch Ultra Plus Reflect (LifeScan). Approximately 90% of participants stated that a consistent color scheme, eg, for low blood glucose (BG) values, should be used across all BGMSs. There was no clear preference among the four tested BGMSs regarding the specific way of displaying color coding. CONCLUSIONS The four BGMSs assessed in this study showed only small differences in an overall sufficient level of accuracy. User handling errors, as observed by study personnel, differed between the systems.
Collapse
|
2
|
Drug Interference in Self-Monitoring of Blood Glucose and the Impact on Patient Safety: We Can Only Guard Against What We Are Looking for. J Diabetes Sci Technol 2024; 18:727-732. [PMID: 36514199 PMCID: PMC11089864 DOI: 10.1177/19322968221140420] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Self-monitoring of blood glucose is a key aspect of diabetes management. Depending on the technology used, however, various substances can jeopardize the reliability of the measurements and precipitate complications with potentially life-threatening consequences when blood glucose was deemed well-controlled. As such, it is important for all involved to be aware of those factors. Officially suggested procedures for testing and alternatives have each their own advantages and limitations, and interferences may be found beyond the substances to be tested provided by the various pertinent institutions. This article reviews these pros and cons and illustrates how interference testing beyond established standards contributes to patient safety. Once identified, interfering substances are included in product labeling and healthcare professionals and users need to be trained to be aware of these risks.
Collapse
|
3
|
The Impact of Blood Glucose Test Strips Reimbursement Limits on Utilization, Costs, and Health-care Utilization in British Columbia. Can J Diabetes 2024; 48:10-17.e5. [PMID: 37611660 DOI: 10.1016/j.jcjd.2023.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 08/14/2023] [Accepted: 08/15/2023] [Indexed: 08/25/2023]
Abstract
OBJECTIVE People living with diabetes and not using insulin may not derive clinically significant benefit from routine glucose self-monitoring. As a result, in 2015, British Columbia (BC) introduced quantity restrictions for blood glucose test strips (BGTS) coverage in public plans. We studied the impact of this policy on utilization, costs, and health-care utilization. METHODS We identified a cohort of adults (≥18 years old) with diabetes between 2013 and 2019. Using BC's administrative data, we studied utilization and costs among individuals with at least one PharmaCare-eligible BGTS claim. Using interrupted time-series analysis, we studied cost savings and determined the level of policy adherence. In addition, we investigated longitudinal changes in all-cause and diabetes-specific physician visits, all-cause hospitalizations, and health-care spending in the 3 to 5 years after policy implementation. RESULTS Over the study period, 279.7 million BGTS were eligible for PharmaCare coverage, on which the government spent $124.3 million. After policy implementation, we observed an immediate decline in average utilization and PharmaCare expenditure on BGTS, leading to an estimated $44.6 million in savings between 2015 and 2019 (95% confidence interval $16.9 to $72.3 million). We found no association between the policy's implementation and health services utilization or overall health-care spending over the long term. CONCLUSIONS Restricting reimbursement for BGTS in BC resulted in significant cost savings without any attendant increase in health services utilization over the subsequent 5 years. This disinvestment freed up resources that could be channeled toward other interventions.
Collapse
|
4
|
Effects of continuous glucose monitoring on glycaemic control in type 2 diabetes: A systematic review and network meta-analysis of randomized controlled trials. Diabetes Obes Metab 2024; 26:362-372. [PMID: 37828805 DOI: 10.1111/dom.15328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/05/2023] [Accepted: 09/26/2023] [Indexed: 10/14/2023]
Abstract
AIMS The aim of this study was to assess the efficacy of continuous glucose monitoring (CGM) versus self-monitoring of blood glucose (SMBG) in maintaining glycaemic control among people with type 2 diabetes mellitus (T2DM). MATERIALS AND METHODS The protocol was registered in PROSPERO (CRD42023387583). PubMed, Web of Science, EMBASE and OVID databases were searched from 1 January 2000 until 31 December 2022 for randomized controlled trials comparing CGM with SMBG in glycaemic control among the outpatients with T2DM. The primary endpoint was glycated haemoglobin, while the secondary endpoints included time in range, time below range and time above range. Both traditional and network meta-analyses were conducted to explore the efficacy of CGM on glycaemic control in T2DM. RESULTS Eleven high-quality studies, involving 1425 individuals with T2DM, were identified. Traditional meta-analysis revealed that CGM exhibited a significantly decreased [mean difference (MD): -0.31, 95% confidence interval (CI) (-0.45, -0.18)], time above range [MD: -9.06%, 95% CI (-16.00, -2.11)], time below range [MD: -0.30%, 95% CI (-0.49, -0.12)] and a significantly increased time in range [MD: 8.49%, 95% CI (3.96, 13.02)] compared with SMBG. The network meta-analysis showed that real-time CGM can improve the glycaemic control of patients with T2DM to the most extent. CONCLUSIONS CGM could provide T2DM with greater benefits in glycaemic management compared with SMBG, particularly in patients using real-time CGM. These findings provide an updated perspective on previous research and offer guidance for CGM use in T2DM.
Collapse
|
5
|
Accuracy of Continuous Glucose Monitoring in an Insulin-Treated Population Requiring Haemodialysis. J Diabetes Sci Technol 2023; 17:971-975. [PMID: 37148160 PMCID: PMC10347996 DOI: 10.1177/19322968231173447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) is revolutionizing diabetes care by giving both patients and the healthcare professionals unprecedented insights into glucose variability and patterns. It is established in National Institute for Health and Care Excellence (NICE) guidance as a standard of care for type 1 diabetes and diabetes in pregnancy under certain conditions. Diabetes mellitus (DM) is recognized as an important risk factor for chronic kidney disease (CKD). Around a third of patients receiving in-center haemodialysis as renal replacement therapy (RRT) have diabetes, either as a direct cause of renal failure or as an additional co-morbidity. Evidence of poor compliance with the current standard of care (self-monitoring of blood glucose [SMBG]) and overall greater morbidity and mortality, suggests this patient population as an ideal target group for CGM. However, there exists no strong published evidence showing the validity of CGM devices in insulin-treated diabetes patients requiring haemodialysis. METHODS We applied a Freestyle Libre Pro sensor to 69 insulin-treated diabetes haemodialysis (HD) patients on a dialysis day. Interstitial glucose levels were obtained, and time matched within 7 minutes to capillary blood glucose testing and any plasma blood glucose levels sent. Data cleansing techniques were applied to account for rapidly correcting hypoglycaemia and poor SMBG technique. RESULTS Clarke-error grid analysis showed 97.9% of glucose values in an acceptable range of agreement (97.3% on dialysis days and 99.1% on non-dialysis days). CONCLUSIONS We conclude that the Freestyle Libre sensor is accurate in measuring glucose levels when compared to glucose as measured by capillary SMBG testing and laboratory obtained serum glucose in patients on HD.
Collapse
|
6
|
Budget impact analysis of the freestyle libre flash continuous glucose monitoring system® in patients with diabetes mellitus type 1 in Chile. Expert Rev Pharmacoecon Outcomes Res 2023; 23:353-363. [PMID: 36701814 DOI: 10.1080/14737167.2023.2171989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVE To estimate the budget impact of covering the FreeStyle Libre Flash Continuous Glucose Monitoring System (FSL) for type 1 Diabetes Mellitus patients (T1DM), compared to self-monitoring of blood glucose (SMBG), from the perspective of public and private third-party payers in Chile. METHODS A budget impact model was developed to estimate the cost difference between SMBG and FSL over five years. Two FSL coverage schemes were assessed. Input parameters were retrieved from the literature review and complemented by expert opinion. Healthcare costs were estimated by a micro-costing approach and reported in USD. RESULTS For a public sector third-party payer, incorporating FSL implied a cost increase up to USD 0.013 per member per month (PMPM) for the fifth year under the broad coverage scheme and a net saving of 0.0001 PMPM (all years) under the restricted coverage scheme. From a private sector third-party payer, incorporating FSL implied savings up to USD 0.028 PMPM (fifth year) for the broad coverage scheme and up to USD 0.012 PMPM (fifth year) for the restricted scheme. CONCLUSION Incorporating the FSL for T1DM patients was associated with a marginal incremental cost for the public sector third-party payer and cost savings in Chile's private healthcare sector.
Collapse
|
7
|
Mobile App Interventions to Improve Medication Adherence Among Type 2 Diabetes Mellitus Patients: A Systematic Review of Clinical Trials. J Diabetes Sci Technol 2023; 17:458-466. [PMID: 34861793 PMCID: PMC10012382 DOI: 10.1177/19322968211060060] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Medication adherence in type 2 diabetes mellitus (T2DM) patients is often suboptimal resulting in complications. There has been a growing interest in using mobile apps for improving medication adherence. OBJECTIVE The objective of this work was to systematically review the clinical trials that have used mobile app-based interventions in T2DM patients for improving medication adherence. METHODOLOGY A systematic search was performed to identify published clinical trials between January 2008 and December 2020 in databases-PubMed, Cochrane Library, and Google Scholar. All studies were assessed for risk of bias using quality rating tool from the Cochrane Handbook for Systematic Reviews of Interventions. RESULTS Seven clinical studies having 649 participants were studied. The median sample size was 58 (range = 41-247) and the median age of participants was 53.2 (range = 48-69.4) years. All studies showed improvements in adherence; however, only three studies reported statically significant improvements in adherence measures. Selected studies were deemed as unclear in their risk of bias and the most common source of risk of bias among the studies was the absence of objective outcome assessment. CONCLUSIONS Mobile apps appear to be effective interventions to help improve medication adherence in T2DM patients compared with conventional care strategies. The features of the App to improvise medical adherence cannot be defined based on the meta-analysis because of heterogeneity of study designs and less number of sample size. Systematically planned studies would set up applicability of mobile apps in the clinical management of T2DM.
Collapse
|
8
|
The Efficacy and Frequency of Self-monitoring of Blood Glucose in Non-insulin-Treated T2D Patients: a Systematic Review and Meta-analysis. J Gen Intern Med 2023; 38:755-764. [PMID: 36403159 PMCID: PMC9971532 DOI: 10.1007/s11606-022-07864-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 10/21/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND Self-monitoring of blood glucose (SMBG) is a useful tool in diabetes management, but its efficacy and optimal application in type 2 diabetes (T2D) patients treated without insulin have been controversial. We aimed to evaluate the efficacy of SMBG in controlling blood glucose levels in non-insulin-treated T2D patients and to determine the optimal frequency and the most appropriate population to benefit from SMBG. METHODS Eligible publications from January 2000 to April 2022 were retrieved from PubMed, Embase, Cochrane Library, and ClinicalTrials.gov databases. Randomized controlled trials comparing SMBG with no SMBG or structured SMBG (S-SMBG, SMBG with defined timing and frequency of glucose measurements) were included. Meta-analyses and sub-analyses were performed to assess the efficacy, optimal frequency, and most appropriate population for SMBG. Risk of bias was assessed regarding randomization, allocation sequence concealment, blinding, incomplete outcome data, selective outcome reporting, and other biases. RESULTS Twenty-two studies involving 6204 participants were identified, including 17 comparing SMBG with no SMBG and 4 comparing SMBG with S-SMBG. SMBG reduced HbA1c (MD -0.30%, 95% CI -0.42 to -0.17) compared with no SMBG, and S-SMBG performed better than SMBG (MD -0.23%, 95% CI -0.38 to -0.07). Subgroup analyses showed that HbA1c control was better with SMBG at 8-11 times weekly (MD -0.35%, 95% CI -0.51 to -0.20) compared with other frequencies and with lifestyle adjustments (MD -0.37%, 95% CI -0.50 to -0.23) than with no adjustments. No significant differences in HbA1c were observed between baseline HbA1c subgroups (≤ 8% and > 8%, P = 0.63) and between diabetes duration subgroups (≤ 6 years and > 6 years, P = 0.72), respectively. DISCUSSION SMBG was effective for controlling HbA1c in non-insulin-treated T2D patients, although lacking detailed monitoring design. Better outcomes were seen with SMBG at 8-11 times weekly and lifestyle adjustment based on SMBG results. TRIAL REGISTRATION PROSPERO (CRD42021285604).
Collapse
|
9
|
Ecological Momentary Assessment of Positive and Negative Affect and Associations with Blood Glucose in Teens with Type 1 Diabetes. J Diabetes Sci Technol 2023; 17:195-200. [PMID: 34330178 PMCID: PMC9846400 DOI: 10.1177/19322968211035451] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND Affect (i.e., emotions) can be associated with diabetes self-care and ambient glucose in teens with type 1 diabetes (T1D). We used momentary sampling to examine associations of daily affectwithblood glucose (BG) monitoring,BG levels,and BG variability in teens with T1D. METHOD Over 2 weeks, 32 teens reported positive and negative affect (Positive and Negative Affect Scale) and BG levels on handheld computers 4x/day, coordinated with planned daily BG checks. BG values were classified as: in-range (70-180 mg/dL); low (<70 mg/dL); severe low (<54 mg/dL); high (>180 mg/dL); severe high (>250 mg/dL). Daily BG variability was derived from BG coefficient of variation (BGCV). To determine associations of positive and negative affect with BG checks, BG levels, and BGCV, separate generalized estimating equations were performed, adjusting for demographic and diabetes-related variables, for the overall sample and stratified by HbA1c (≤8%, >8%). RESULTS Teens (44% male, ages 14-18, 63% pump-treated, HbA1c 8.8 ± 1.4%) reported 51% in-range, 6% low (2% severe low), and 44% high (19% severe high) BG. In teens with HbA1c ≤8%, positive affect was associated with in-range BG (OR = 1.08, 95% CI = 1.04-1.13, P = .0002), reduced odds of very low glucose (OR = 0.35, 95% CI = 0.16-0.74, P = .006), and less daily BGCV (β = -0.9; 95% CI = -1.6, -0.2; P = .01). In teens with HbA1c >8%, negative affect was associated with less likelihood of checking BG (OR = 0.75, 95% CI = 0.64-0.87, P = .0003). CONCLUSIONS Our findings shed light on individual differences in metabolic reactivity based on glycemic levels and the importance of incorporating affect into automated insulin delivery systems.
Collapse
|
10
|
Effect of continuous glucose monitoring compared with self-monitoring of blood glucose in gestational diabetes patients with HbA1c<6%: a randomized controlled trial. Front Endocrinol (Lausanne) 2023; 14:1174239. [PMID: 37152928 PMCID: PMC10155499 DOI: 10.3389/fendo.2023.1174239] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Accepted: 03/29/2023] [Indexed: 05/09/2023] Open
Abstract
Objective This study evaluated the effect of continuous glucose monitoring (CGM) versus self-monitored blood glucose (SMGB) in gestational diabetes mellitus (GDM) with hemoglobin A1c (HbA1c) <6%. Methods From January 2019 to February 2021, 154 GDM patients with HbA1c<6% at 24-28 gestational weeks were recruited and assigned randomly to either SMBG only or CGM in addition to SMBG, with 77 participants in each group. CGM was used in combination with fingertip blood glucose monitoring every four weeks until antepartum in the CGM group, while in the SMBG group, fingertip blood glucose monitoring was applied. The CGM metrics were evaluated after 8 weeks, HbA1c levels before delivery, gestational weight gain (GWG), adverse pregnancy outcomes and CGM medical costs were compared between the two groups. Results Compared with patients in the SMBG group, the CGM group patients had similar times in range (TIRs) after 8 weeks (100.00% (93.75-100.00%) versus 99.14% (90.97-100.00%), p=0.183) and HbA1c levels before delivery (5.31 ± 0.06% versus 5.35 ± 0.06%, p=0.599). The proportion with GWG within recommendations was higher in the CGM group (59.7% versus 40.3%, p=0.046), and the newborn birth weight was lower (3123.79 ± 369.58 g versus 3291.56 ± 386.59 g, p=0.015). There were no significant differences in prenatal or obstetric outcomes, e.g., cesarean delivery rate, hypertensive disorders, preterm births, macrosomia, hyperbilirubinemia, neonatal hypoglycemia, respiratory distress, and neonatal intensive care unit admission >24 h, between the two groups. Considering glucose monitoring, SMBG group patients showed a lower cost than CGM group patients. Conclusions For GDM patients with HbA1c<6%, regular SMBG is a more economical blood glucose monitoring method and can achieve a similar performance in glycemic control as CGM, while CGM is beneficial for ideal GWG.
Collapse
|
11
|
Efficacy of intermittent short-term use of a real-time continuous glucose monitoring system in non-insulin-treated patients with type 2 diabetes: A randomized controlled trial. Diabetes Obes Metab 2023; 25:110-120. [PMID: 36053813 DOI: 10.1111/dom.14852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 08/12/2022] [Accepted: 08/22/2022] [Indexed: 12/14/2022]
Abstract
AIM To evaluate the efficacy of intermittent short-term use of a real-time continuous glucose monitoring (RT-CGM) system in non-insulin-treated patients with type 2 diabetes (T2D) uncontrolled with oral antidiabetic drugs (OADs). MATERIALS AND METHODS In this multicentre, randomized prospective study, 61 participants were randomly assigned to treatment group 1 (one session of RT-CGM), treatment group 2 (two sessions of RT-CGM with a 3-month interval between sessions) and a control group. All participants used blinded continuous glucose monitoring for up to 6 days with education before randomization, and RT-CGM was additionally applied for 1 week in the intervention groups. The primary outcome was change in HbA1c at 6 months. RESULTS Among 61 participants, 48 subjects completed the study (baseline HbA1c 8.2% ± 0.5%). At 3 months, a significant HbA1c reduction was observed in treatment group 1 (adjusted difference = -0.60%, P = .044) and treatment group 2 (adjusted difference = -0.64%, P = .014) compared with the control group. However, at 6 months, only treatment group 2 achieved a significant HbA1c reduction (adjusted difference = -0.68%, P = .018). Especially in the treatment groups, patients performing self-monitoring of blood glucose (SMBG) at least 1.5 times/day showed a significant HbA1c improvement, at both 3 and 6 months, but those performing SMBG less than 1.5 times/day showed no significant improvement. CONCLUSIONS In non-insulin-treated patients with T2D uncontrolled with OADs, intermittent short-term use of RT-CGM was an effective method for glucose control, especially in those performing SMBG frequently.
Collapse
|
12
|
Abstract
BACKGROUND The analytical quality of a blood glucose monitoring system (BGMS) is often assessed according to the requirements described in the international standard ISO 15197. However, the mean absolute relative difference (MARD) is sometimes used as well. This analysis aims at providing empirical data from BGMS evaluation studies conducted according to ISO 15197 and at providing an estimation of how MARD and percentage of measurement results within ISO accuracy limits are related. METHODS Results of 77 system accuracy evaluations conducted according to ISO 15197 were used to calculate MARD between BGMS and a laboratory comparison method's results (glucose oxidase or hexokinase method). Additionally, bias and 95%-limits of agreement (LoA) using the Bland and Altman method were calculated. RESULTS MARD results ranged from 2.3% to 20.5%. The lowest MARD of a test strip lot that showed <95% of results within ISO limits was 6.1%. The distribution of MARD results shows that only 3.6% of test strip lots with a MARD equal to or below 7% showed <95% of results within ISO limits (2.2% of all test strip lots). Bias of test strip lots that showed ≥95% of results within the limits ranged from -10.3% to +7.4%. The half-width of the 95%-LoA of test strip lots that showed ≥95% of results within the limits ranged from 4.8% to 24.0%. CONCLUSION There is a threshold MARD that may allow an estimate whether ISO 15197 requirements are fulfilled, but this statement cannot be made with certainty.
Collapse
|
13
|
Efficacy of Continuous Glucose Monitoring on Glycaemic Control in Pregnant Women with Gestational Diabetes Mellitus-A Systematic Review. J Clin Med 2022; 11:jcm11102932. [PMID: 35629058 PMCID: PMC9145267 DOI: 10.3390/jcm11102932] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/20/2022] [Accepted: 05/20/2022] [Indexed: 12/25/2022] Open
Abstract
Gestational diabetes mellitus (GDM) is one of the most common complications of pregnancy, affecting up to 14% of pregnant women. The population of patients with risk factors of GDM is increasing; thus, it is essential to improve management of this condition. One of the key factors affecting perinatal outcomes in GDM is glycaemic control. Until recently, glucose monitoring was only available with self-monitoring of blood glucose (SMBG). However, nowadays, there is a new method, continuous glucose monitoring (CGM), which has been shown to be safe in pregnancy. Since proper glycaemia assessment has been shown to affect perinatal outcomes, we decided to perform a systematic review to analyse the role of CGM in glycaemic control in GDM. We conducted a web search of the MEDLINE, EMBASE, Cochrane Library, Scopus, and Web of Science databases according to the PRISMA guidelines. The web search was performed by two independent researchers and resulted in 14 articles included in the systematic review. The study protocol was registered in the PROSPERO database with registration number CRD42021289883. The main outcome of the systematic review was determining that, when compared, CGM played an important role in better glycaemic control than SMBG. Furthermore, glycaemic control with CGM improved qualification for insulin therapy. However, most of the articles did not reveal CGM’s role in improving neonatal outcomes. Therefore, more studies are needed to analyse the role of CGM in affecting perinatal outcomes in GDM.
Collapse
|
14
|
Assessment of insulin adherence in diabetic outpatients: an observational study. ANNALES PHARMACEUTIQUES FRANÇAISES 2022; 80:827-836. [PMID: 35568247 DOI: 10.1016/j.pharma.2022.05.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/11/2022] [Accepted: 05/09/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVES In the management of diabetic patients on insulin therapy, adherence to medication is a key element for avoiding chronic complications. The purpose of this study was to evaluate diabetic patients' ability to translate glycemic results into an appropriate insulin dose and thus, adherence to insulins. METHODS This was an observational, retrospective, monocentric pilot study. Diabetic patients on insulin therapy being followed at the metabolic and endocrine diseases department were divided into two groups depending on their mode of glycemic control at home: capillary glycemia (Notebook group) or interstitial glycemia using the FreeStyle Libre® flash system (FSL group). Adherence was assessed based on the rate of compliance in adapting insulin doses to the prescribed protocols (depending on type of insulin, glycemic targets, and patients' characteristics) by a pharmacy resident and a senior diabetologist. Good adherence was defined as a minimum rate of 80% of conforming insulin injections for each patient. RESULTS A total of 50 patients were included, 35 in the Notebook group and 15 in the FSL group. Two-thirds of patients were non-adherent to insulin. Dose adjustment errors mainly concerned rapid-acting insulin with 51.1% of non- conformities, 10.0% of which were due to underdosing in the Notebook group and 21.7% to overdosing in the FSL group. Hyperglycemia was predominant in both populations with a median time in range of 19.0% in the FSL group and well below recommendations (>70%). CONCLUSIONS Despite the use of increasingly efficient, easy-to-use devices in diabetes monitoring, insulin non-adherence and glycemic imbalance are unresolved major issues. Diabetic patients require reinforced medical follow-up for optimal insulin management.
Collapse
|
15
|
Abstract
In this issue of Journal of Diabetes Science and Technology, Baumstark et al. evaluated the analytical performance of a bench-top laboratory glucose analyzer (SUPER-GL) intended for replacement for the YSI2300-STAT analyzer, that served for several decades as a comparator method in clinical and analytical studies of blood glucose monitoring systems (BGMS). The authors concluded that the SUPER-GL's overall performance is comparable to that of YSI2300-STAT, and has the potential to be a candidate comparator analyzer. However, the question is if we need to recommend as a "comparator method," a specific device, that measure glucose using the same analytical method with most BGMS. In this analysis we present our point of view hoping to generate a discussion on the necessity for such a replacement.
Collapse
|
16
|
Adjustment of Insulin Pump Settings in Type 1 Diabetes Management: Advisor Pro Device Compared to Physicians' Recommendations. J Diabetes Sci Technol 2022; 16:364-372. [PMID: 33100030 PMCID: PMC8861776 DOI: 10.1177/1932296820965561] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
AIMS To compare insulin dose adjustments made by physicians to those made by an artificial intelligence-based decision support system, the Advisor Pro, in people with type 1 diabetes (T1D) using an insulin pump and self-monitoring blood glucose (SMBG). METHODS This was a multinational, non-interventional study surveying 17 physicians from 11 countries. Each physician was asked to provide insulin dose adjustments for the settings of the pump including basal rate, carbohydrate-to-insulin ratios (CRs), and correction factors (CFs) for 15 data sets of pumps and SMBG of people with T1D (mean age 18.4 ± 4.8 years; eight females; mean glycated hemoglobin 8.2% ± 1.4% [66 ± 11mmol/mol]). The recommendations were compared among the physicians and between the physicians and the Advisor Pro. The study endpoint was the percentage of comparison points for which there was an agreement on the direction of insulin dose adjustments. RESULTS The percentage (mean ± SD) of agreement among the physicians on the direction of insulin pump dose adjustments was 51.8% ± 9.2%, 54.2% ± 6.4%, and 49.8% ± 11.6% for the basal, CR, and CF, respectively. The automated recommendations of the Advisor Pro on the direction of insulin dose adjustments were comparable )49.5% ± 6.4%, 55.3% ± 8.7%, and 47.6% ± 14.4% for the basal rate, CR, and CF, respectively( and noninferior to those provided by physicians. The mean absolute difference in magnitude of change between physicians was 17.1% ± 13.1%, 14.6% ± 8.4%, and 23.9% ± 18.6% for the basal, CR, and CF, respectively, and comparable to the Advisor Pro 11.7% ± 9.7%, 10.1% ± 4.5%, and 25.5% ± 19.5%, respectively, significant for basal and CR. CONCLUSIONS Considerable differences in the recommendations for changes in insulin dosing were observed among physicians. Since automated recommendations by the Advisor Pro were similar to those given by physicians, it could be considered a useful tool to manage T1D.
Collapse
|
17
|
Efficacy of Digitally Supported and Real-Time Self-Monitoring of Blood Glucose-Driven Counseling in Patients with Type 2 Diabetes Mellitus: A Real-World, Retrospective Study in North India. Diabetes Metab Syndr Obes 2022; 15:23-33. [PMID: 35023937 PMCID: PMC8743499 DOI: 10.2147/dmso.s345785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 12/16/2021] [Indexed: 04/20/2023] Open
Abstract
PURPOSE Poor glycemic control is prevalent in patients with type 2 diabetes mellitus (T2DM) in India. This study aims to understand the effectiveness of a smartphone-connected glucometer, real-time feedback, and contextualized counseling on glycemic control and hypoglycemic episodes in T2DM patients. METHODS This retrospective, multicenter study reviewed the medical records of T2DM patients belonging to several cities of north India, who were digitally engaged with a smartphone-connected glucometer and who had received at least one counseling session between September 2019 and July 2020. Intervention included self-monitoring of blood glucose (SMBG) using a smartphone-connected glucometer enabled with real-time transmission of information to certified diabetes educators (CDE) and their corresponding counseling based on SMBG findings. RESULTS Of 7111 adult T2DM patients included in this study, majority (75%) of the patients received a single session of counseling, and the remaining patients received 2 (16.7%), 3 (5%), 4 (2%), or ≥5 (1.3%) sessions. The mean age of the patients was 51.6 years, and the majority (77.9%) were males. Digital monitoring of BG and counseling with CDE significantly reduced the mean fasting (by 9.6%), pre-prandial (by 9.9%), and post-prandial (by 9.2%) BG values in 53%, 52%, and 54% of patients, respectively. The majority (81.4%) of patients showed no hypoglycemic episode (≤70 mg/dL) post-counseling. The hypoglycemia episodes observed with FBG, pre-prandial, and post-prandial BG values were reduced significantly by 58.5%, 48.1%, and 61.8%, respectively, post-counseling. CONCLUSION Digitally supported and real-time SMBG-driven counselling was effective in glycemic control and reduction of hypoglycemic episodes in T2DM patients in India. Moreover, reduction in hypoglycemia may be due to back end real-time support of CDE intervention.
Collapse
|
18
|
The Importance of Patient and Family Engagement, the Needs for Self-Monitoring of Blood Glucose (SMBG) - Our Perspectives Learned Through a Story of SMBG Assistive Devices Made by a Husband of the Patient with Diabetes. Diabetes Metab Syndr Obes 2022; 15:1627-1638. [PMID: 35642182 PMCID: PMC9148577 DOI: 10.2147/dmso.s363762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 05/13/2022] [Indexed: 11/23/2022] Open
Abstract
Despite some negative reports regarding the need for the self-monitoring of blood glucose (SMBG), including the issue of cost-effectiveness, there are still many users, and in diabetes treatment, which is largely dependent on the patient's self-care, SMBG remains an important tool in establishing such self-care habits, with several reports supporting this notion. In addition, devices are needed to assist in SMBG for patients with diabetes who have difficulty performing SMBG, such as the elderly or those with visual impairment. In current diabetes care, it is reported that patient-centered care that respects the preferences, needs, and values of individual patients and personalized care that consider the characteristics and comorbidities of each patient are important. Through a case study of a patient with diabetes who had difficulty performing SMBG due to visual impairment, we learned of the needs of SMBG and its assistive devices and the importance of patient and family engagement with emphasis on patient-centered and personalized care. We herein report what we learned through this case in the form of perspectives. Through this report, we hope that medical professionals involved in diabetes care will learn of the importance and needs of these issues and apply them to their actual clinical practice.
Collapse
|
19
|
Patients With SGLT2 Inhibitor Therapy Can Reliably Measure Their Blood Glucose Without Interference Issues When Up-to-Date Potentiometric and Amperometric Blood Glucose Measurement Systems Are Used. J Diabetes Sci Technol 2022; 16:261-263. [PMID: 34696609 PMCID: PMC8875053 DOI: 10.1177/19322968211050370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
20
|
Factors Related to Diabetes Self-Management Among Patients with Type 2 Diabetes: A Chinese Cross-Sectional Survey Based on Self-Determination Theory and Social Support Theory. Patient Prefer Adherence 2022; 16:925-936. [PMID: 35418746 PMCID: PMC8995176 DOI: 10.2147/ppa.s335363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 12/22/2021] [Indexed: 12/27/2022] Open
Abstract
PURPOSE Self-management behavior (SMB) plays a significant role in glycemic control. This study aimed to explore the factors related to SMB among patients with type 2 diabetes and how these factors interacted with each other. PATIENTS AND METHODS Patients diagnosed with type 2 diabetes were recruited from 18 community healthcare stations (CHSs) from six community healthcare centers (CHCs) in Beijing, China from April to May in 2017. Motivation, competence, autonomy support, social support, self-management skills, adherence to self-monitoring of blood glucose (SMBG) and haemoglobin A1c (HbA1c) measurement were tested by questionnaire. Correlation analysis and path analysis were performed so as to identify the factors associated with patients' SMB. RESULTS A total of 532 participants completed this study. Participants who have good compliance to SMBG got higher scores in social support (F = 7.68, p = 0.01), competence (F = 10.47, p = 0.01), and skills (F = 12.34, p < 0.01). Higher competence (β = 0.03, P < 0.001), higher social support (β = 0.01, P < 0.001), better skills(β = 0.01, P < 0.001) directly led to better adherence to SMBG. Social support had a positive effect on autonomy support (β = 0.69, P < 0.001), motivation (β = 0.45, P < 0.001), competence (β = 0.28, P < 0.001), skills (β = 0.14, P < 0.001), which was also indirectly linked to better adherence to SMBG. Better self-management skills directly led to better adherence to HbA1c measurement (β = 0.03, P < 0.001). Social support had a positive effect on autonomy support (β = 0.69, P < 0.001), motivation (β = 0.45, P < 0.001), competence (β = 0.28, P < 0.001), skills (β = 0.14, P < 0.001), which was also indirectly linked to better adherence to HbA1c measurement. CONCLUSION Self-determination theory and social support theory were practical in explaining SMB in Chinese population. Competence, motivation and social support played an important role in diabetic self-management. Paying attention to the promotion of individual's intrinsic motivation and self-efficacy may be able to help patients maintain self-management behavior in the long-term routine.
Collapse
|
21
|
Abstract
INTRODUCTION Self-monitoring of blood glucose (BG) is important in diabetes management, allowing people with diabetes (PWD) to assess responses to diabetes therapy and to inform if they are attaining their glycemic targets. This study assessed the accuracy and user performance (UP) of a new blood glucose monitoring system (BGMS), CONTOUR®PLUS ELITE, according to International Organization for Standardization (ISO) 15197:2013 criteria and also more stringent criteria. METHODS In laboratory Study 1, capillary fingertip blood samples from 100 PWD were evaluated using the new BGMS. In clinical Study 2, 130 PWD had Yellow Springs Instrument (YSI) analyzer reference measurements against subject-obtained fingertip and palm blood, and trial staff-obtained venous blood. The new BGMS was tested with test strips from three different lots. A UP questionnaire assessed ease of use. RESULTS Study 1: 100% of combined accuracy results fulfilled ISO criteria (±15 mg/dL at BG <100 mg/dL; ±15% at BG ≥100 mg/dL); 99.8% fulfilled more stringent criteria (±10 mg/dL at BG <100 mg/dL; ±10% at BG ≥100 mg/dL). Error grid analysis showed that 100% of results were within zone A. Study 2: >98% of subject- and 100% of trial staff-obtained performance results met ISO criteria. Most subjects (>96%) found the BGMS easy to use. CONCLUSION The new BGMS exceeded minimum ISO 15197:2013-specified standards for both accuracy and UP criteria, along with the more stringent accuracy criteria. These data show that this new BGMS can be a useful tool in managing glycemic control for PWD.
Collapse
|
22
|
A Pilot Trial to Evaluate the Accuracy of a Novel Non-Invasive Glucose Meter. SENSORS 2021; 21:s21206704. [PMID: 34695917 PMCID: PMC8538169 DOI: 10.3390/s21206704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 10/05/2021] [Accepted: 10/07/2021] [Indexed: 11/16/2022]
Abstract
The non-invasive self-monitoring of blood glucose (SMBG) has been the subject of intense investigation over recent decades. We conducted a pilot study designed to examine a novel non-invasive glucometer, the HGR GWave, utilizing radiofrequency (RF) sensing. Blood glucose levels assessed by this HGR prototype were compared to measurements performed by a hexokinase core laboratory assay during an oral glucose tolerance test (oGTT) for 5 subjects with type 2 diabetes. The HGR glucose meter readings were also compared to two Abbot Freestyle® glucose meters, which were also used for calibration. The accuracy of the results was evaluated through the calculation of relative absolute difference (RAD), specified percentage differences between 43 reference glucose measurements, and using comparator measurements. The median RAD was −4.787. We detected 79.04%, 92.99% and 97.64% of HGR readings within ±10%, ±15% and ±20% of the reference glucose measurements. The HGR readings had a high correlation with reference lab glucose measurements with R2 = 0.924 (95% CI 0.929–0.979; p < 0.0001). When compared to the Freestyle® glucose meters 94.3% and 100% of the readings were within ±5% and ±10%, with R2 = 0.975 (0.975–0.994; p < 0.0001). The HGR prototype glucose meter was found to be accurate in detecting real-time blood glucose during an oGTT in this small pilot study. A study with a broader range of blood glucose levels is needed to further assess its accuracy and its suitability for clinical use.
Collapse
|
23
|
Patients With Diabetes Using a New Glucose Meter With Blood Sugar Mentor and Dynamic Color Range Indicator Features Show Improved Interpretation and Willingness to Act on Blood Glucose Results (ASCEND Study). J Diabetes Sci Technol 2021; 15:1168-1176. [PMID: 32830523 PMCID: PMC8411471 DOI: 10.1177/1932296820949873] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND We examined whether dynamic color range indicator (DCRI) and blood sugar mentor (BSM) features in a new blood glucose meter could improve interpretation of results and encourage patient action. METHODS One hundred and thirty three people with type 2 (T2D) (n = 73) or type 1 diabetes (T1D) (n = 60) evaluated information first without and then with DCRI or BSM guidance using interactive exercises. RESULTS Subjects improved their ability to categorize results into low, in range, or high glycemic ranges by 29% (T2D) and 22% (T1D) (each P < .001). There was significantly greater willingness to act on high and low results shown with DCRI or BSM screens. Subjects also expressed a high degree of satisfaction with these features. CONCLUSIONS Use of DCRI and BSM in this meter may help patients improve their diabetes management decisions.
Collapse
|
24
|
|
25
|
Abstract
Optimal glycemic control remains challenging and elusive for many people with diabetes. With the comprehensive clinical evidence on safety and efficiency in large populations, and with broader reimbursement, the adoption of continuous glucose monitoring (CGM) is rapidly increasing. Standardized visual reporting and interpretation of CGM data and clear and understandable clinical targets will help professionals and individuals with diabetes use diabetes technology more efficiently, and finally improve long-term outcomes with less everyday disease burden. For the majority of people with type 1 or type 2 diabetes, time in range (between 70 and 180 mg/dL, or 3.9 and 10 mmol/L) target of more than 70% is recommended, with each incremental increase of 5% towards this target being clinically meaningful. At the same time, the goal is to minimize glycemic excursions: a recommended target for a time below range (< 70 mg/dL or < 3.9 mmol/L) is less than 4%, and time above range (> 180 mg/dL or 10 mmol/L) less than 25%, with less stringent goals for older individuals or those at increased risk. These targets should be individualized: the personal use of CGM with the standardized data presentation provides all necessary means to accurately tailor diabetes management to the needs of each individual with diabetes.
Collapse
|
26
|
Analysis of a Unique Postmarket Surveillance Dataset That a Glucose Test-Strip Demonstrates no Evidence of Interference and Robust Clinical Accuracy Irrespective of the Prescription Medication Status of a Large Cohort of Patients With Diabetes. J Diabetes Sci Technol 2021; 15:82-90. [PMID: 31478385 PMCID: PMC7783023 DOI: 10.1177/1932296819873053] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Despite a marked increase in polypharmacy in patients with diabetes there have been no thorough evaluations of the impact of polypharmacy on the accuracy of any current blood glucose monitoring (BGM) system. This study evaluated the accuracy of a BGM test-strip with respect to polypharmacy using a large clinical registry dataset. METHODS Medication profiles were analyzed for 830 subjects (334 with type 1 [T1D] and 496 with type 2 diabetes [T2D]) attending three hospitals. Blood samples were analyzed to determine clinical accuracy of the BGM test-strip compared to a laboratory comparator. RESULTS Across the 830 subjects, 473 different medications (41 diabetes and 432 nondiabetes) were recorded. Patients took on average 6.5 (n = 1-23) individual medications and 4 (n = 1-11) unique classes of medication. Clinical accuracy to EN ISO 15197:2015 criteria was met irrespective of increasing average number of individual medication, categorized from 1 to 4, 5 to 8, 9 to 12, and >12 taken per subject (97.7%, 98.4%, 98.1%, and 98.5%, respectively). Clinical accuracy to EN ISO 15197:2015 criteria was also met across 15 classes of medication using the combined dataset (98.1%; 13 003/13 253). Surveillance error grid analysis showed 98.8% (13 079/13 232) of readings presented no clinical risk. No individual class or combination of medication classes impacted clinical accuracy of the BGM test-strip. CONCLUSIONS This comprehensive analysis for this specific test-strip platform demonstrated no evidence of interference and robust clinical accuracy of this test strip, irrespective of the prescription medication status of patients with diabetes.
Collapse
|
27
|
Clinical Inertia and 2-Year Glycaemic Trajectories in Patients with Non-Newly Diagnosed Type 2 Diabetes Mellitus in Primary Care: A Retrospective Cohort Study. Patient Prefer Adherence 2021; 15:2497-2508. [PMID: 34795477 PMCID: PMC8593594 DOI: 10.2147/ppa.s328165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 10/27/2021] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE To analyse diabetes treatment, treatment change and self-management behaviours in association with 2-year glycaemic trajectories in patients with non-newly diagnosed type 2 diabetes mellitus in Chinese primary care. METHODS This was an observational, multi-centre, longitudinal, retrospective cohort study. Clinical data of 4690 subjects were extracted from electronic medical records, including serial glycated haemoglobin A1c (HbA1c) measurements, antidiabetic medication records and compliance to exercise, diet, medications and self-monitoring of blood glucose (SMBG). Patterns of longitudinal HbA1c trajectories were identified using the percentage of HbA1c measurements <7.5% from the second available HbA1c measurement. Clinical relevance of the clusters was assessed through multivariable analysis. RESULTS Approximately half of the participants demonstrated good glycaemic control; of these, 34.5% demonstrated stable, good control, and 13.7% demonstrated relatively good control. About 16.2% demonstrated moderate control, and 35.6% demonstrated poor control. From the good to poor control groups, the percentage of subjects treated with insulin at baseline and during the follow-up period increased gradually, while the percentage of subjects adhering to exercise, diet, medications and SMBG decreased gradually. Compared with baseline, the adherence to exercise, diet, medications and SMBG improved significantly. Approximately 50% and 26% of subjects in the two poorest control groups, respectively, experienced treatment changes. After multivariable adjustments, baseline HbA1c ≥7.5%, HbA1c change ≥-0.5% from baseline to visit 1, insulin treatment, treatment change, poor adherence to diet, exercise, SMBG during the follow-up period and HbA1c measurements <3 per year were significantly associated with poorer glycaemic control. CONCLUSION We identified four longitudinal HbA1c trajectories in patients with non-newly diagnosed type 2 diabetes. Even if baseline HbA1c is suboptimal, aggressive treatment changes, good adherence during the follow-up period, ≥3 HbA1c measurements per year and reducing HbA1c levels to a certain extent by the first follow-up visit were important for good, stable, long-term glycaemic control.
Collapse
|
28
|
Abstract
BACKGROUND Noninvasive glucose monitoring (NIGM) in diabetes is a long-sought-for technology. Among the many attempts Raman spectroscopy was considered as the most promising because of its glucose specificity. In this study, a recently developed prototype (GlucoBeam, RSP Systems A/S, Denmark) was tested in patients with type 1 diabetes to establish calibration models and to demonstrate proof of concept for this device in real use. METHODS The NIGM table-top prototype was used by 15 adult subjects with type 1 diabetes for up to 25 days at home and in an in-clinic setting. On each day, the subjects performed at least six measurement units throughout the day. Each measurement unit comprised two capillary blood glucose measurements, two scans with an intermittent scanning continuous glucose monitoring (CGM) system, and two NIGM measurements using the thenar of the subject's right hand. RESULTS Calibration models were established using data from 19 to 24 days. The remaining 3-8 days were used for independent validation. The mean absolute relative difference of the NIGM prototype was 23.6% ± 13.1% for the outpatient days, 28.2% ± 9.9% for the in-clinic day, and 26.3% ± 10.8% for the complete study. Consensus error grid analysis of the NIGM prototype for the complete study showed 93.6% of values in clinically acceptable zones A and B. CONCLUSIONS This proof of concept study demonstrated a practical realization of a Raman-based NIGM device, with performance on par with early-generation CGM systems. The findings will assist in further performance improvements of the device.
Collapse
|
29
|
Factors Associated with Adherence to Self-Monitoring of Blood Glucose Among Young People with Type 1 Diabetes in China: A Cross-Sectional Study. Patient Prefer Adherence 2021; 15:2809-2819. [PMID: 34938070 PMCID: PMC8686228 DOI: 10.2147/ppa.s340971] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 12/03/2021] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Self-monitoring of blood glucose (SMBG) plays a crucial role in the maintenance of glycemic control in young people with type 1 diabetes mellitus (T1DM), but most of them do not perform SMBG as recommended. Few studies comprehensively explored factors that correlate with adherence to SMBG among this population on the basis of a framework. Hence, the aims of this study were to describe adherence to SMBG among young people with T1DM in China and explore its associating factors according to the Self and Family Management (SFM) framework. METHODS A cross-sectional study was conducted on young people with T1DM in Hunan Province of China from July to August 2020. Based on the SFM framework, self-reported questionnaires were organized for the collection of data on adherence to SMBG, socio-demographic and clinical factors, resources, health care system, and personal factors. Factors associated with adherence to SMBG were determined through multivariate logistic regression analysis. RESULTS A total of 165 young people were invited, of which 122 (73.9%) completed the questionnaires. The mean age was 12.41 years (SD = 3.18), and the proportion of young people who adhered to SMBG was 53.3%. Multivariate logistic regression analysis revealed that children aged 8-12 years (OR = 0.188, P = 0.002), from two-parent families (OR = 0.232, P = 0.019), and with better personal factors (eg, with more information of SMBG, OR = 1.072, P = 0.020; lower diabetes-related worry, OR = 0.917, P = 0.031; higher level of pain during SMBG, OR = 1.852, P = 0.001), had better adherence to SMBG. CONCLUSION Nearly half of the young people with T1DM were not adherent to SMBG in China. Clinicians need to pay more attention to adolescents from single-parent families with regard to their adherence to SMBG. Providing management strategies of SMBG, including delivering SMBG-related information, decreasing diabetes-related worry, and relieving pain related to SMBG, may improve adherence.
Collapse
|
30
|
Cutaneous adverse events in a randomized controlled trial of flash glucose monitoring among youth with type 1 diabetes mellitus. Pediatr Diabetes 2020; 21:1516-1524. [PMID: 32935921 DOI: 10.1111/pedi.13121] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/13/2020] [Accepted: 08/28/2020] [Indexed: 12/01/2022] Open
Abstract
BACKGROUND The literature regarding flash glucose monitoring (FGM)-associated cutaneous adverse events (AE) is limited. OBJECTIVES This study among youth participating in a 6 month randomized controlled trial aimed to compare cutaneous AE between FGM and self-monitored blood glucose (SMBG) use and evaluate premature FGM sensor loss. METHODS Patients aged 13 to 20 years with type 1 diabetes were randomized to intervention (FGM and usual care) or control (SMBG and usual care). Participants self-reported cutaneous AEs electronically every 14 days. Reports were analyzed to determine frequency, type, and severity of cutaneous AEs, and evaluate premature sensor loss. RESULTS Sixty-four participants were recruited; 33 randomized to FGM and 31 to control. In total, 80 cutaneous AEs were reported (40 in each group); however, the proportion of participants experiencing cutaneous AEs was greater in the FGM group compared to control (58% and 23% respectively, P = .004). FGM participants most frequently reported erythema (50% of AEs), while controls most commonly reported skin hardening (60% of AEs). For FGM users, 80.0% of cutaneous AEs were mild, 17.5% moderate, and 2.5% severe. Among controls, 82.5% of cutaneous AEs were mild and 17.5% moderate. One participant ceased using FGM due to recurring cutaneous AEs. Additionally, over 6 months, 82% of FGM participants experienced at least one premature sensor loss, largely unrelated to a cutaneous AE. CONCLUSIONS Cutaneous FGM-associated AEs are common, and mostly rated as mild. However, the majority of users continued FGM despite cutaneous AEs. Awareness of cutaneous complications and mitigation measures may reduce cutaneous AEs and improve the overall experience of FGM.
Collapse
|
31
|
Meeting the New FDA Standard for Accuracy of Self-Monitoring Blood Glucose Test Systems Intended for Home Use by Lay Users. J Diabetes Sci Technol 2020; 14:912-916. [PMID: 32059615 PMCID: PMC7753858 DOI: 10.1177/1932296820906184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The OneTouch Verio Reflect blood glucose monitor (BGM) has market clearance in several countries based in part on fulfilling the lay user and system accuracy criteria described in ISO15197:2015. However, the Food and Drug Administration (FDA) does not recognize the accuracy criteria in ISO15197 as a basis for gaining regulatory clearance for these devices. The current study evaluates the BGM using the accuracy guidelines issued by the agency for self-monitoring blood glucose test systems for over-the-counter use. Glucose results were accurate vs comparator over a wide glucose range and met lay user and glucose accuracy criteria at extreme glucose values as described in the FDA guidance.Clinicaltrials.gov NCT03851549.
Collapse
|
32
|
Glucose Homeostasis, Fetal Growth and Gestational Diabetes Mellitus in Pregnancy after Bariatric Surgery: A Scoping Review. J Clin Med 2020; 9:jcm9092732. [PMID: 32847052 PMCID: PMC7564394 DOI: 10.3390/jcm9092732] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 08/17/2020] [Accepted: 08/19/2020] [Indexed: 12/12/2022] Open
Abstract
Background: Pregnancies in women with a history of bariatric surgery are becoming increasingly prevalent. Surgically induced metabolic changes benefit mother and child, but can also lead to some adverse pregnancy outcomes. Knowledge about glucose homeostasis in these pregnancies could elucidate some of the mechanisms behind these outcomes. This review focusses on glucose homeostasis and birth weight. Methods: We considered papers dealing with glucose homeostasis, gestational diabetes mellitus (GDM) and/or small-for-gestational age infants (SGA) in pregnancies with a history of sleeve gastrectomy (SG) or Roux-en-y gastric bypass (RYGB). Results: Since an OGTT is unreliable to diagnose GDM in a pregnancy after bariatric surgery, the true incidence of GDM is unknown. Alternative screening strategies are needed. Furthermore, these pregnancies are marked by frequent hypoglycemic events as well as wide and rapid glycemic excursions, an issue that is very likely underreported. There is a lack of uniformity in reporting key outcomes and a large variation in study design and control population. Conclusion: Alteration of glucose homeostasis in a pregnancy after bariatric surgery should be further studied using unequivocal definition of key concepts. Glycemic control may prove to be a modifiable risk factor for adverse pregnancy outcomes such as the delivery of an SGA baby.
Collapse
|
33
|
Effect of a standard schema of self-monitoring blood glucose in patients with poorly controlled, non-insulin-treated type 2 diabetes mellitus: A controlled longitudinal study. JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY 2020; 27:e1-e11. [PMID: 32757545 DOI: 10.15586/jptcp.v27isp2.680] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 06/15/2020] [Indexed: 11/18/2022]
Abstract
The effect of self-monitoring of blood glucose (SMBG) on glycemic control with regard to non-insulin-treated Type 2 diabetes mellitus (NIT-Type 2 DM) is still a controversial topic. Against this backdrop, we sought to compare the effect of a continuous short-term SMBG schema with as-usual treatment, based on changes in oral antidiabetic treatment in patients with poorly controlled Type 2 DM. We reviewed 492 NIT-Type 2 DM record charts, selecting 27 patients, with poor glycemic control, who were thought to self-monitor their blood glucose levels (SMBG group). We then compared them with 27 patients treated with modifying drugs or diets to achieve and maintain the glycemic target (Control Group). Haemoglobin A1c (HbA1c) and fasting plasma glucose (FPG) were evaluated at baseline, after 3 and 6 months. HbA1c values decreased after 3 and 6 months in the SMBG group (P < 0.001 on both occasions) and in the control group (P < 0.05 and P < 0.01, respectively), but without a significant difference between the two groups when compared at the same time. The FPG progressively decreased in both groups, reaching a significant difference in the SMBG group after 3 months and in the control group after 6 months, and without a significant difference between the two groups. The SMBG schema used in our study could be adopted for target groups before proceeding to the next therapeutic enhancement drug step, representing a useful tool that can help diabetic patients in raising awareness of and treating their disease.
Collapse
|
34
|
|
35
|
Surveillance Accuracy of Smartphone-Dependent Glucose Meters in the Measurement of Plasma Glucose. Indian J Endocrinol Metab 2020; 24:181-186. [PMID: 32699787 PMCID: PMC7333746 DOI: 10.4103/ijem.ijem_580_19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 12/02/2019] [Accepted: 12/20/2019] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND Along with stand-alone glucose monitors, smartphone-dependent glucose meters (SDGM) are available for self-monitoring of blood glucose (SMBG). These display-less devices, connected to a smartphone, measure glucose and display report on a smartphone screen, which can be easily shared with doctors. AIM The aim of this study was to check the accuracy of the available SDGMs in relation to the laboratory reference method. MATERIALS AND METHODS Two available SDGMs: BeatO™ and GlucoMe™ were tested. A total of 104 venous blood samples were tested for glucose in SDGMs and by the reference method. The accuracy of the report was checked by the International Standards Organization (ISO), American Diabetes Association (ADA), and Clinical Laboratory Improvement Amendments (CLIA) criteria. Clarke error grid analysis (CEGA) was carried out to find the suitability of SDGM in clinical usage. RESULTS Mean plasma glucose (n = 104) level from laboratory report was 106.48 ± 44.58 mg/dL, that from BeatO™ was 105.78 ± 52.6, and GlucoMe™ was 99.72 ± 51.22. The accuracy was lower than that recommended by ISO 2013 (29.8% and 30.77% error in BeatO™ and GlucoMe™, respectively), ADA (63.46% and 74% error in BeatO™ and GlucoMe™, respectively), and CLIA (42.31% and 46.15% error in BeatO™ and GlucoMe™, respectively) criteria. According to CEGA, BeatO™ and GlucoMe™ can guide correct treatment in diabetes mellitus patients for 74% and 71% of measurement, respectively. CONCLUSION The accuracy of both the SDGMs was lower than that suggested by ISO, ADA, and CLIA criteria. The result of this study would help patients and doctors in informed choice for the procurement of glucose monitors.
Collapse
|
36
|
Patient Satisfaction With a New, High Accuracy Blood Glucose Meter That Provides Personalized Guidance, Insight, and Encouragement. J Diabetes Sci Technol 2020; 14:318-323. [PMID: 31375031 PMCID: PMC7196872 DOI: 10.1177/1932296819867396] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Accurate self-monitoring of blood glucose (SMBG) is a key component of effective self-management of glycemic control. METHODS The OneTouch Verio Reflect and OneTouch Ultra Plus Reflect BG monitoring systems were evaluated for accuracy in a clinical setting. Subjects also used the meters for a one-week trial period and reported their level of satisfaction with meter features. RESULTS Both systems were accurate over a wide glucose range and met lay user and system accuracy BG standards described in ISO15197:2015. Subjects felt that the features of a meter with a dynamic color range indicator and personalized guidance, insight, and encouragement could provide significant benefits to them in the management of their diabetes. CONCLUSIONS Both meter systems were accurate over a wide glucose range and the features of the meter and messages were well received by patients in a short take-home trial. CLINICAL TRIAL REGISTRATION Clinicaltrials.gov NCT0351542.
Collapse
|
37
|
Benefits and limitations of continuous glucose monitoring in type 1 diabetes. Expert Rev Endocrinol Metab 2020; 15:41-49. [PMID: 31928104 DOI: 10.1080/17446651.2020.1706482] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Accepted: 12/16/2019] [Indexed: 12/14/2022]
Abstract
Introduction: Type 1 diabetes (T1D) is a chronic condition characterized by a complete deficiency in insulin production. Optimal management requires constant knowledge of glucose levels for safe and effective insulin administration. Self-monitoring of blood glucose (SMBG) using capillary blood glucose meters is cumbersome and provides limited information to guide management. Continuous glucose monitoring (CGM) technology addresses many of these gaps, but itself has limitations which have prevented people with diabetes and their clinicians from fully embracing this technology. This review covers the benefits and limitations of CGM use, and looks toward future application of this technology in the management of T1D.Areas covered: Impact of CGM on physical and psychosocial outcomes in people with T1D. Barriers to CGM uptake. Integration with insulin pumps and other technologies. Opportunities for future application.Expert opinion: CGM technology will be utilized by the majority of people with T1D and increasing numbers of people with type 2 diabetes due to improved insurance coverage and easier-to-use systems. Its use as part of artificial pancreas systems will add further utility, as it will help to protect from both hypoglycemia and hyperglycemia. People with diabetes will spend more time in range and experience fewer acute and chronic complications.
Collapse
|
38
|
A Review of Research Progress on Glycemic Variability and Gestational Diabetes. Diabetes Metab Syndr Obes 2020; 13:2729-2741. [PMID: 32801819 PMCID: PMC7414929 DOI: 10.2147/dmso.s261486] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 07/11/2020] [Indexed: 01/27/2023] Open
Abstract
Gestational diabetes mellitus (GDM) is associated with many adverse obstetric outcomes and neonatal outcomes, including preeclampsia, Cesarean section, and macrosomia. Active screening and early diabetes control can reduce the occurrence of adverse outcomes. Glycosylated hemoglobin (HbA1c) only reflects average blood glucose levels, but not glycemic variability (GV). Studies have shown that GV can cause a series of adverse reactions, and good control of GV can reduce the incidence of adverse pregnancy outcomes in patients with GDM. In order to provide clinicians with a better basis for diagnosis and treatment, this study reviewed the measurement, evaluation, and control of GV, the importance of GV for patients with GDM, and correlations between GV and maternal and neonatal outcomes.
Collapse
|
39
|
Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip. Expert Rev Med Devices 2019; 17:75-82. [PMID: 31825686 DOI: 10.1080/17434440.2020.1704253] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Background: Self-monitoring of blood glucose (SMBG) can play a key role in diabetes management. The CONTOUR®NEXT ONE (Ascensia Diabetes Care, Parsippany, NJ, USA) blood glucose monitoring system (BGMS) has been developed for use with CONTOUR®NEXT test strips. The meter connects to the CONTOUR™ Diabetes application on a mobile device, and the Second-Chance® sampling feature recognizes insufficient sample volume, prompting the patient to apply more blood to the same strip if needed (sample re-application).Research design and methods: Two studies evaluated CONTOUR®NEXT ONE BGMS accuracy with sample re-application: a laboratory study (performance under various controlled conditions) and a clinical study (performance in the hands of 52 people with diabetes). A formal International Organization for Standardization (ISO) evaluation has been reported previously; here, accuracy criteria in the laboratory and clinical studies were aligned with ISO 15197:2013 sections 6.3.3 and 8.2, respectively.Results: All results under all conditions in the laboratory study, and with glucose concentrations <100 and ≥100 mg/dL in the clinical study, were within ±15 mg/dL or ±15% of reference measurements. In both studies, all results were within Zone A of the Parkes-Consensus Error Grid.Conclusions: These data demonstrate that the accuracy of the CONTOUR®NEXT ONE BGMS was maintained with sample re-application.
Collapse
|
40
|
A comparison of bolus insulin dose errors based on results of a clinical trial of five blood glucose monitoring systems. Ther Deliv 2019; 10:793-799. [PMID: 31789119 DOI: 10.4155/tde-2019-0047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: Inaccurate blood glucose monitoring system (BGMS) results may lead to insulin dosing errors and adverse clinical outcomes. Results & methodology: This post-hoc analysis used a model to estimate the bolus insulin dose error associated with each of the five BGMSs, for a hypothetical person with diabetes (assuming a standardized meal and target blood glucose of 100 mg/dl). Differences in dose-error distribution between BGMSs were statistically tested. The 95% dose-error range for each BGMS was (insulin units): CONTOUR®PLUS, -1.1-0.7; Accu-Chek® Active, -2.4-0.7; Accu-Chek® Performa, -2.9-0.8; FreeStyle Freedom, from -5.5 to -0.5; OneTouch® SelectSimple™, -4.1-3.0. Conclusion: The CONTOUR®PLUS BGMS was associated with a statistically significantly smaller model-estimated median bolus insulin dose-error and dosing error range, compared with the other BGMSs.
Collapse
|
41
|
Use of radar plots to compare the analytical performance of five blood glucose monitoring systems. Ther Deliv 2019; 10:783-792. [PMID: 31674291 DOI: 10.4155/tde-2019-0046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: The radar plot is a relatively new way of communicating blood glucose monitoring system (BGMS) accuracy and precision: data points positioned within concentric circles represent the magnitude (increasing with distance from center) and direction (relative to horizontal) of BGMS-error (center = equivalency with reference instrument measurement). This manuscript aims to demonstrate the utility of radar plots as visual tools for interpretation of BGMS analytical performance. Results & methodology: Radar plots were constructed for five BGMSs, to compare BGMS blood glucose results with reference instrument measurements. Conclusion: Radar plots are a useful tool for the visualization of BGMS analytical performance, communicating accuracy, precision and the satisfaction of certain regulatory criteria at a glance.
Collapse
|
42
|
Proof of Concept Study to Assess the Influence of Oxygen Partial Pressure in Capillary Blood on SMBG Measurements. J Diabetes Sci Technol 2019; 13:1105-1111. [PMID: 30841739 PMCID: PMC6835173 DOI: 10.1177/1932296819833369] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Measurement results provided by blood glucose monitoring systems (BGMS) can be affected by various influencing factors. For some BGMS using glucose oxidase (GOx)-based test strips, one of these factors is the oxygen partial pressure (pO2) of the applied blood sample. Because assessing the potential influence of pO2 when measuring capillary blood samples is not straight-forward, we performed a proof of concept study. METHOD Influence of pO2 was investigated for two GOx-based BGMS (BGMS A and B). Measurement results of the GOx-based BGMS were compared with measurement results from a pO2-independent BGMS (BGMS C). A total of 119 samples from 60 subjects were measured, twice with BGMS C, then 6 times each with BGMS A and BGMS B or vice versa, and again twice with BGMS C. Immediately afterward, pO2 was determined. Linear regression analysis based on relative differences between results from BGMS A or BGMS B and results from BGMS C was performed to estimate the degree of pO2 influence. RESULTS The relative bias between the lowest and highest pO2 values differed by 14.3% for BGMS A, indicating a pO2 influence that might be clinically relevant, and by 9.7% for BGMS B, indicating that pO2 influence may be too small to be reliably detected because of the BGMS' imprecision. CONCLUSIONS This proof of concept study showed that with the procedures used, a potentially clinically relevant influence of pO2 in capillary blood samples on GOx-based BGMS could be detected. Further larger-scale studies are needed to verify this influence.
Collapse
|
43
|
Glucose management for rewards: A randomized trial to improve glucose monitoring and associated self-management behaviors in adolescents with type 1 diabetes. Pediatr Diabetes 2019; 20:997-1006. [PMID: 31271239 PMCID: PMC6786915 DOI: 10.1111/pedi.12889] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 06/04/2019] [Accepted: 06/18/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND This randomized, controlled trial evaluated a monetary-based reinforcement intervention for increasing self-monitoring of blood glucose (SMBG) among youth with poorly controlled type 1 diabetes. METHODS After a 2-week baseline, 60 participants were randomized to enhanced usual care (EUC) or Reinforcers. The Reinforcers group earned monetary rewards for SMBG and associated behaviors such as uploading glucose meters. Reinforcers were withdrawn at 24 weeks. A follow-up evaluation occurred at 36 weeks. RESULTS Participants in the reinforcers group increased the proportion of days they completed ≥4 SMBG from 14.6% at baseline to 64.4%, 47.5%, and 37.8% at 6, 12, and 24 weeks, respectively. In contrast, EUC participants declined from 22.7% at baseline to 17.5%, 10.5%, and 11.1% (Ps < .01 vs EUC at all time points). Group differences were attenuated but remained significant after withdrawal of reinforcers. Effect sizes for SMBG were very large during reinforcement and large after withdrawal of reinforcers. In the reinforcers group, mean A1c dropped from 9.5% ± 1.2% at baseline to 9.0% ± 1.3% at week 6 and 9.0% ± 1.4% at week 12. For EUC, A1c was 9.2% ± 0.2% at baseline and ranged from 9.2% ± 1.5% to 9.6% ± 1.6% throughout the study (P < .05 vs EUC). Group differences in A1c were no longer significant at weeks 24 and 36. Effect sizes for A1c were small during reinforcement and also after withdrawal of reinforcement. CONCLUSIONS Monetary-based reinforcement of adolescents with type 1 diabetes caused durable increases in SMBG. Modification of the reinforcement structure may be needed to sustain improved metabolic control in this challenging age group.
Collapse
|
44
|
Diabetes self care activities among adults 20 years and above residing in a resettlement colony in East Delhi. Indian J Public Health 2019; 62:104-110. [PMID: 29923533 DOI: 10.4103/ijph.ijph_249_17] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Background Self-care activities are the cornerstone of diabetes care that ensures patients participation to achieve optimal glycemic control and to prevent complications. Objective The aim of this study is to find the level of self-care activities among diabetics aged ≥20 years residing in a resettlement colony in East Delhi and its association with sociodemographic factors, disease, and treatment profile. Methods Using cross-sectional survey, 168 known diabetic patients were selected from Nand Nagri, a resettlement colony in East Delhi. Data were collected using Hindi translation of revised version-Summary of Diabetic Self Care Activities along with a pretested semi-open-ended questionnaire. Self-care was assessed on six parameters as follows: (a) general diet, (b) specific diet, (c) exercise, (d) blood sugar testing, (e) foot-care, and (f) smoking. The study period was from November 2014 to April 2016. Results Nearly 35.1% of respondents belonged to 60-69 years age group. About 52.4% of respondents were female. Fifty-two diabetics (31%) reported having practised diet control on all 7 days in the past 1 week. Nearly 39.3% of patients did not perform any physical activity. The blood test was not practised by 92.3% of respondents. Foot-care was practised by only 19% of patients. There was a significant association between general diet among diabetics with family support (P = 0.020), place of diagnosis (P = 0.033), and treatment funds (P = 0.017). The exercise score among diabetics who were below the poverty line was higher than those above poverty line (P = 0.029). Younger age (P = 0.005) and treatment with insulin (P = 0.008) were positively associated with blood glucose testing. The foot-care practice was better in patients aware of complications and foot-care practices (P < 0.001). Conclusion Self-care activities among diabetic patients were very poor. Self-management educational programs at hospitals along with information, education, and communication activities at the community level and one-to-one counseling are recommended.
Collapse
|
45
|
Continuous Glucose Monitoring Versus Self-monitoring of Blood Glucose in Type 2 Diabetes Mellitus: A Systematic Review with Meta-analysis. Cureus 2019; 11:e5634. [PMID: 31700737 PMCID: PMC6822918 DOI: 10.7759/cureus.5634] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Every eleventh adult has diabetes, and every third has prediabetes. Over 95% of diabetics are of type 2. It is well established that diabetes doubles the risk of heart disease and stroke apart from increasing the risk of microvascular complications. Hence, strict glycemic control is necessary. However, it increases the risk of hypoglycemia, especially in patients with longstanding diabetes. Continuous glucose monitors (CGM) use a sensor to continuously measure the glucose levels in the interstitial fluid every 10 seconds and gives out mean values every five minutes. CGMs are emerging tools in the management of type 2 diabetes. The prime objective of this review is to find out if there is enough supporting evidence, suggesting that continuous glucose monitoring is more effective than self-monitoring of blood glucose (SMBG) in type 2 diabetes. We conducted a systematic literature search in Medline (PubMed) looking for any studies addressing our objective. It is observed that there is a varying level of evidence supporting that employing a CGM can reduce glycated hemoglobin (HbA1c), hypoglycemic events, and increase patient satisfaction. However, some studies reported no significant benefits. This systematic review with meta-analysis concludes that the use of CGM in type 2 diabetes mellitus (T2DM) is beneficial, as it significantly reduces HbA1c compared to the usual method of SMBG. The pooled mean difference in HbA1c was -0.25 (-0.45, -0.06) and statistically significant (at p = 0.01) when comparing CGM to SMBG.
Collapse
|
46
|
Health Care Professionals' Clinical Perspectives and Acceptance of a Blood Glucose Meter and Mobile App Featuring a Dynamic Color Range Indicator and Blood Sugar Mentor: Online Evaluation in Seven Countries. JMIR Hum Factors 2019; 6:e13847. [PMID: 31271146 PMCID: PMC6636235 DOI: 10.2196/13847] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 05/30/2019] [Accepted: 06/04/2019] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Despite many new therapies and technologies becoming available in the last decade, people with diabetes continue to struggle to achieve good glycemic control. Innovative and affordable solutions are needed to support health care professionals (HCPs) to improve patient outcomes. OBJECTIVE To gather current self-management perceptions of HCPs in seven countries and investigate HCP satisfaction with a new glucose meter and mobile app featuring a dynamic color range indicator and a blood sugar mentor. METHODS A total of 355 HCPs, including 142 endocrinologists (40.0%), 108 primary care physicians (30.4%), and 105 diabetes nurses (29.6%), were recruited from the United Kingdom (n=50), France (n=50), Germany (n=50), India (n=54), Algeria (50), Canada (n=51), and the United States (n=50). HCPs experienced the OneTouch Verio Reflect glucose meter and the OneTouch Reveal mobile app online from their own office computers using interactive demonstrations via webpages and multiple animations. After providing demographic and clinical practice insights, HCPs responded to statements about the utility of the system. RESULTS Concerning current practice, 83.1% (295/355) of HCPs agreed that poor numeracy or health literacy was a barrier for their patients. A total of 85.9% (305/355) and 92.1% (327/355) of HCPs responded that type 2 diabetes (T2D) and type 1 diabetes (T1D) patients were aware of what represented a low, in-range, or high blood glucose result. Only 62.0% (220/355) felt current glucose meters made it easy for patients to understand if results were in range. A total of 50.1% (178/355) and 78.0% (277/355) of HCPs were confident that T1D and T2D patients took action for low or high results. A total of 87.0% (309/355) agreed that the ColorSure Dynamic Range Indicator could help them teach patients how to interpret results and 88.7% (315/355) agreed it made them more aware of hyper- and hypoglycemic results so they could take action. A total of 83.7% (297/355) of HCPs agreed that the Blood Sugar Mentor feature gave personalized guidance, insight, and encouragement so patients could take action. A total of 82.8% (294/355) of HCPs also agreed that the Blood Sugar Mentor provided real-time guidance to reinforce the goals HCPs had set so patients could take steps to manage their diabetes between office visits. After experiencing the full system, 85.9% (305/355) of HCPs agreed it was beneficial for patients with lower numeracy or health literacy; 96.1% (341/355) agreed that it helped patients understand when results were low, in range, or high; and 91.0% (323/355) agreed that the way it displayed diabetes information would make patients more inclined to act upon results. A total of 89.0% (316/355) of HCPs agreed that it would be helpful for agreeing upon appropriate in-range goals for their patients for their next clinic visit. CONCLUSIONS This multi-country online study provides evidence that HCPs were highly satisfied with the OneTouch Verio Reflect meter and the OneTouch Reveal mobile app. Each of these use color-coded information and the Blood Sugar Mentor feature to assist patients with interpreting, analyzing, and acting upon their blood glucose results, which is particularly beneficial to keep patients on track between scheduled office visits.
Collapse
|
47
|
Assessing quality of glycemic control: Hypo- and hyperglycemia, and glycemic variability using mobile self-monitoring of blood glucose system. Health Informatics J 2019; 26:287-297. [PMID: 30693833 DOI: 10.1177/1460458218824756] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Although mobile applications bring potential benefits of metabolic control for patients with diabetes, their effect on glycemic fluctuation has been less widely explored. The goal of this study was to utilize data from the Mobile Self-Monitoring of Blood Glucose System to obtain a picture of the metabolic progression. Twenty-seven adults with type 2 diabetes mellitus were recruited to receive a mobile diabetes self-care system for a six-week period. The approach to the interpretation of glycemic control patterns, utilizes the following methods: 1) Graphical displays of the percentage of hyper-and-hypoglycemia episodes; 2) Pattern recognition of glycemic variability based on a simple equation involving both the standard deviation and the mean. Analytical results reveal that short-term usage of the developed system stabilizes the week-by-week glycemic fluctuations. Four categories were established to distinguish different patterns of patients' glycemic variation. If patterns of glycemic control can be recognized or interpreted by newly designed mobile applications, then the collection and analysis of metabolic variation will greatly help both health care providers and patients in effective diabetes management.
Collapse
|
48
|
The Accuracy of Continuous Glucose Monitoring and Flash Glucose Monitoring During Aerobic Exercise in Type 1 Diabetes. J Diabetes Sci Technol 2019; 13:140-141. [PMID: 30295040 PMCID: PMC6313274 DOI: 10.1177/1932296818804550] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
49
|
Application and Utility of Continuous Glucose Monitoring in Pregnancy: A Systematic Review. Front Endocrinol (Lausanne) 2019; 10:697. [PMID: 31681170 PMCID: PMC6798167 DOI: 10.3389/fendo.2019.00697] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 09/26/2019] [Indexed: 12/25/2022] Open
Abstract
Background: In the past decade, continuous glucose monitoring (CGM) has been proven to have similar accuracy to self-monitoring of blood glucose (SMBG) and yet provides better therapy optimization and detects trends in glucose values due to higher frequency of testing. Even though the feasibility and utility of CGM has been proven successfully in Type 1 and 2 diabetes, there is a lack of knowledge of its application and effectiveness in pregnancy, especially in gestational diabetes mellitus (GDM). In this review, we aimed to summarize and evaluate the updated scientific evidence on the application of CGM in pregnancies complicated with GDM. Methods: A search using keywords related to CGM and GDM on PubMed was conducted and articles were filtered based on full text, year of publication (Jan 1998-Dec 2018), human subject studies, and written in English. Reviews and duplicate articles were removed. A final total of 29 articles were included in this review. Results: In terms of maternal and fetal outcomes, inconsistent evidence was reported. Among GDM patients using CGM and SMBG, two randomized controlled trials (RCTs) found no significant differences in macrosomia, birth weight (BW), and gestational age (GA) at delivery between these two groups, while one prospective cohort found a lower incidence of cesarean section and macrosomia in CGM use subjects. Furthermore, CGM use was consistently found to have increased detection in dysglycemia and glycemic variability compared to SMBG. In terms of clinical utility, CGM use led to more treatment adjustments and lower gestational weight gain (GWG). Lastly, CGM use showed higher postprandial glucose levels in GDM-complicated pregnancies than in normal pregnancies. Conclusion: Current updated evidence suggests that CGM is superior to SMBG among GDM pregnancies in terms of detecting hypoglycemic and hyperglycemic episodes, which might result in an improvement of maternal and fetal outcomes. In addition, CGM detects a wider glycemic variability in GDM mothers than non-GDM controls. Further research with larger sample sizes and complete pregnancy coverage is needed to explore the clinical utility such as screening and predictive values of CGM for GDM.
Collapse
|
50
|
Adherence to self-monitoring of blood glucose in Chinese patients with type 2 diabetes: current status and influential factors based on electronic questionnaires. Patient Prefer Adherence 2019; 13:1269-1282. [PMID: 31413552 PMCID: PMC6662864 DOI: 10.2147/ppa.s211668] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 06/30/2019] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND AND PURPOSE Self-monitoring of blood glucose (SMBG) is important to the management of diabetes mellitus, yet most patients with type 2 diabetes mellitus (T2DM) do not perform SMBG as recommended. The current status and influential factors of SMBG in China have not been well investigated. This study aimed to describe the present status of SMBG adherence in China and investigate the influential factors based on electronic questionnaires. PATIENTS AND METHODS A cross-sectional study was conducted from June to July of 2017 at hospitals in Changsha, China. Seven hundred and twenty-one patients with T2DM completed the information‑motivation‑behavioral (IMB) skills questionnaire and other electronic questionnaires composed of demographic and clinical characteristics as well as diabetes-related and psychological scales. Univariate comparisons and multivariate logistic regression were used to explore the relationships among SMBG adherence and related factors. RESULTS Seven hundred and twenty-one patients with valid questionnaires were included. Only 27.5% (198/721) of the patients with T2DM were SMBG adherent based on the guideline of the Chinese Diabetes Society (CDS) in 2017. Among all groups of treatment regimens, the rate of SMBG adherence was highest at 36.6% (82/224) in patients on oral hypoglycaemic drugs (OHAs). In multivariable analysis, the treatment of OHAs (OR =3.731, CI 2.162-6.437) and diet/exercise (OR =3.534, CI 1.841-6.783), the patient having their own blood glucose meter (OR =6.916, CI 4.054-11.800) and a higher education level (OR =3.780, CI 1.688-8.466) were significantly associated with SMBG adherence. CONCLUSION Most Chinese patients with T2DM did not perform SMBG as recommended. The treatment of OHAs and diet/exercise, the patient having their own blood glucose meter, a higher education level and other factors were correlates of SMBG adherence. There is clearly a need for prospective, multicenter, large-scale studies to explore the reasons for patients' failure to practice SMBG adherence.
Collapse
|