1
|
Rapid Volumetric Optoacoustic Tracking of Individual Microparticles In Vivo Enabled by a NIR-Absorbing Gold-Carbon Shell. ACS APPLIED MATERIALS & INTERFACES 2021; 13:48423-48432. [PMID: 34613688 DOI: 10.1021/acsami.1c15509] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Rapid volumetric in vivo visualization of circulating microparticles can facilitate new biomedical applications, such as blood flow characterization or targeted drug delivery. However, existing imaging modalities generally lack the sensitivity to detect the weak signals generated by individual micrometer-sized particles distributed across millimeter- to centimeter-scale depths in living mammalian tissues. Also, the temporal resolution is typically insufficient to track the particles in an entire three-dimensional region. Herein, we introduce a new type of monodisperse (4 μm) silica-core microparticle coated with a shell formed by a multilayered structure of carbon nanotubes (CNT) and gold nanoparticles (AuNP) to provide strong optoacoustic (OA) absorption-based contrast. We capitalize on the unique advantages of a state-of-the-art high-frame-rate OA tomography system to visualize and track the motion of these core-shell particles individually and volumetrically as they flow throughout the mouse brain vasculature. The feasibility of localizing individual solid particles smaller than red blood cells opens new opportunities for mapping the blood flow velocity, enhancing the resolution and visibility of OA images, and developing new biosensing assays.
Collapse
|
2
|
Selenium Vacancy Engineering Using Bi 2Se 3 Nanodots for Boosting Highly Efficient Photonic Hyperthermia. ACS APPLIED MATERIALS & INTERFACES 2021; 13:48378-48385. [PMID: 34632756 DOI: 10.1021/acsami.1c13107] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Despite bismuth-based energy conversion nanomaterials having attracted extensive attention for nanomedicine, the nanomaterials suffer from major shortcomings including low tumor accumulation, long internal retention time, and undesirable photothermal conversion efficiency (PCE). To combat these challenges, bovine serum albumin and folic acid co-modified Bi2Se3 nanomedicine with rich selenium vacancies (abbreviated as VSe-BS) was fabricated for the second near-infrared (NIR-II) light-triggered photonic hyperthermia. More importantly, selenium vacancies on the crystal planes (0 1 5) and (0 1 11) of VSe-BS with similar formation energies could be distinctively observed via aberration-corrected scanning transmission electron microscopy images. The defect engineering endows VSe-BS with enhanced conductivity, making VSe-BS possess outstanding PCE (54.1%) in the NIR-II biowindow and desirable photoacoustic imaging performance. Tumor ablation studies indicate that VSe-BS possesses satisfactory therapeutic outcomes triggered by NIR-II light. These findings give rise to inspiration for further broadening the biological applications of defect engineering bismuth-based nanomaterials.
Collapse
|
3
|
PEGylated Indium Nanoparticles: A Metallic Contrast Agent for Multiwavelength Photoacoustic Imaging and Second Near-Infrared Photothermal Therapy. ACS APPLIED MATERIALS & INTERFACES 2021; 13:46343-46352. [PMID: 34558285 DOI: 10.1021/acsami.1c13578] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Indium, a low melting point metal, is well-known for constructing eutectic gallium-indium liquid metal. However, unlike liquid metal nanoparticles, the biomedical applications of metallic indium nanoparticles (In NPs) remain in their infancy. Herein, an ultrasound-assisted liquid-reduction synthesis strategy was developed to prepare PEGylated In NPs, which were then used as a high-performance contrast agent for enhancing multiwavelength photoacoustic imaging and second near-infrared (NIR-II) photothermal therapy of the 4T1 breast tumor. The obtained In NPs depicted remarkable optical absorption from the first near-infrared (NIR-I) to NIR-II region and a high photothermal conversion efficiency of 41.3% at 1064 nm, higher than the majority of conventional NIR-II photothermal agents. Upon injection into the tumor, the photoacoustic intensities of the tumor section post-injection were obviously increased by 2.59-, 2.62-, and 4.27-fold of those of pre-injection by using excitation wavelengths of 750, 808, and 970 nm, respectively, depicting an excellent multiwavelength contrast capability of photoacoustic imaging. In addition, efficient ablation of the 4T1 tumor was achieved through the photothermal performance of PEGylated In NPs under NIR-II laser irradiation. Importantly, as the widely used element in the clinic, In NPs were highly biocompatible in vitro and in vivo. Therefore, this work pioneered the biomedical applications of PEGylated In NPs for cancer diagnosis and treatment.
Collapse
|
4
|
Effect of a Radiotherapeutic Megavoltage Beam on Ultrasound Contrast Agents. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1857-1867. [PMID: 33810887 DOI: 10.1016/j.ultrasmedbio.2021.02.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 02/22/2021] [Accepted: 02/23/2021] [Indexed: 06/12/2023]
Abstract
Collateral damage to healthy surrounding tissue during conventional radiotherapy increases when deviations from the treatment plan occur. Ultrasound contrast agents (UCAs) are a possible candidate for radiation dose monitoring. This study investigated the size distribution and acoustic response of two commercial formulations, SonoVue/Lumason and Definity/Luminity, as a function of dose on clinical megavoltage photon beam exposure (24 Gy). SonoVue samples exhibited a decrease in concentration of bubbles smaller than 7 µm, together with an increase in acoustic attenuation and a decrease in acoustic scattering. Definity samples did not exhibit a significant response to radiation, suggesting that the effect of megavoltage photons depends on the UCA formulation. For SonoVue, the influence of the megavoltage photon beam was especially apparent at the second harmonic frequency, and can be captured using pulse inversion and amplitude modulation (3.5-dB decrease for the maximum dose), which could eventually be used for dosimetry in a well-controlled environment.
Collapse
|
5
|
Albumin-Templated Bi 2Se 3-MnO 2 Nanocomposites with Promoted Catalase-Like Activity for Enhanced Radiotherapy of Cancer. ACS APPLIED MATERIALS & INTERFACES 2021; 13:28650-28661. [PMID: 34124895 DOI: 10.1021/acsami.1c05669] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Novel and effective radiosensitizers that can enhance radiosensitivity of tumor tissues and increase the local radiation dose are highly desirable. In this work, templated by bovine serum albumin (BSA), Bi2Se3-MnO2 nanocomposites (Bi2Se3-MnO2@BSA) were fabricated via biomineralization, while Bi2Se3 nanodots act as radiosensitizers to increase the local radiation dosage because of their strong X-ray attenuation ability, and MnO2 with catalase-like activity can increase the oxygen concentration in tumors by triggering the decomposition of tumor endogenous H2O2 so as to improve the hypoxia-associated radioresistance of tumors. Owing to the interaction of the two components in the interface, Bi2Se3-MnO2@BSA showed promoted catalytic activity compared to MnO2@BSA, favoring tumor radiotherapy (RT) sensitization. BSA templating enabled the nanocomposites with high colloidal stability and biocompatibility as well as satisfactory tumor targeting both in vitro and in vivo; thus, an enhanced RT efficacy was obtained. Moreover, the proposed Bi2Se3-MnO2@BSA exhibited excellent performances in computerized tomography and magnetic resonance imaging. Thus, this work provides a tumor microenvironment-responsive multifunctional theranostic nanoagent with an improved performance for imaging-guided tumor RT sensitization.
Collapse
|
6
|
Shortwave infrared polymethine fluorophores matched to excitation lasers enable non-invasive, multicolour in vivo imaging in real time. Nat Chem 2020; 12:1123-1130. [PMID: 33077925 PMCID: PMC7680456 DOI: 10.1038/s41557-020-00554-5] [Citation(s) in RCA: 131] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 08/17/2020] [Indexed: 01/06/2023]
Abstract
High-resolution, multiplexed experiments are a staple in cellular imaging. Analogous experiments in animals are challenging, however, due to substantial scattering and autofluorescence in tissue at visible (350-700 nm) and near-infrared (700-1,000 nm) wavelengths. Here, we enable real-time, non-invasive multicolour imaging experiments in animals through the design of optical contrast agents for the shortwave infrared (SWIR, 1,000-2,000 nm) region and complementary advances in imaging technologies. We developed tunable, SWIR-emissive flavylium polymethine dyes and established relationships between structure and photophysical properties for this class of bright SWIR contrast agents. In parallel, we designed an imaging system with variable near-infrared/SWIR excitation and single-channel detection, facilitating video-rate multicolour SWIR imaging for optically guided surgery and imaging of awake and moving mice with multiplexed detection. Optimized dyes matched to 980 nm and 1,064 nm lasers, combined with the clinically approved indocyanine green, enabled real-time, three-colour imaging with high temporal and spatial resolutions.
Collapse
|
7
|
Biodegradable pH-responsive amorphous calcium carbonate nanoparticles as immunoadjuvants for multimodal imaging and enhanced photoimmunotherapy. J Mater Chem B 2020; 8:8261-8270. [PMID: 32812632 PMCID: PMC7530098 DOI: 10.1039/d0tb01453b] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Development of bioresponsive theranostic nanoparticles to enhance cancer diagnostics and control cancer metastasis is highly desirable. In this study, we developed such a bioresponsive theranostic nanoparticle for synergistic photoimmunotherapy. In particular, these nanoparticles were constructed by embedding indocyanine green (ICG) into Mn2+-doped amorphous calcium carbonate (ACC(Mn)) nanoparticles, followed by loading of the Toll-like-receptor-7 agonist imiquimod (IMQ). The IMQ@ACC(Mn)-ICG/PEG nanoparticles respond to the acidic pH of the tumor microenvironment (TME) and co-deliver ICG and IMQ into the tumor. Selective phototherapy was achieved upon activation using a near-infrared laser. In the presence of IMQ and arising from phototherapeutically treated tumor cells, tumor-associated antigens give rise to a strong antitumor immune response. Reversal of the immunosuppressive TME via H+ scavenging of the tumor through ACC nanoparticles effectively inhibits tumor metastases. Moreover, the combination of ICG and Mn2+ also serves as an advanced contrast agent for cancer multimode imaging. Overall, these bioresponsive nanoparticles provide a promising approach for cancer theranostics with promising potential for future clinical translation.
Collapse
|
8
|
Multifunctional siRNA-Laden Hybrid Nanoplatform for Noninvasive PA/IR Dual-Modal Imaging-Guided Enhanced Photogenetherapy. ACS APPLIED MATERIALS & INTERFACES 2020; 12:22613-22623. [PMID: 32338491 DOI: 10.1021/acsami.0c04533] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Small interfering RNA (siRNA)-induced gene therapy has been recognized as a promising avenue for effective cancer treatment, while easy enzymatic degradation, poor transfection efficiency, nonspecific biodistribution, and uncontrolled release hinder its extensive clinical applications. Zeolitic imidazolate frameworks-8 (ZIF-8) have emerged as promising drug carriers without an in-depth exploration in programmable siRNA delivery. Herein, we report a multifunctional PDAs-ZIF-8 (PZ) nanoplatform for delivering siRNA with combined photothermal therapy (PTT) and gene therapy (GT) via the noninvasive guidance of photoacoustic (PA)/near-infrared (IR) dual-modal imaging. The ingenious PZ nanocarriers mediated the tumor-specific accumulation of therapeutic siRNA without undesired degradation and preleakage. The pH-responsive ZIF-8 decomposed in an acidic tumor microenvironment that was accompanied by the release of siRNA payloads for cleaving target mRNA in gene silencing therapy. Meanwhile, the polydopamine nanoparticles (PDAs) could simultaneously serve as a powerful noninvasive PA/IR imaging contrast agent and versatile photothermal agent for diagnosis-guided photogenetherapy. The systematic in vitro and in vivo experimental explorations demonstrated that our PDAs-siRNA-ZIF-8 (PSZ) could greatly enhance the therapeutic efficiency as compared with the corresponding PTT or GT monotherapy. This work holds great potential to advance the development of more intelligent diagnosis and therapeutic strategies, thus supplying promising smart nanomedicines in the near future.
Collapse
|
9
|
Analysis of acoustic nonlinearity parameter B/A in liquids containing ultrasound contrast agents. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1394. [PMID: 31472549 DOI: 10.1121/1.5123486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Accepted: 08/06/2019] [Indexed: 06/10/2023]
Abstract
The acoustic nonlinearity parameter B/A plays a significant role in the characterization of acoustic properties of various biomaterials and biological tissues. It has the potential to be a favorable imaging modality in contrast ultrasound imaging with coated microbubbles. However, the development of effective means for evaluating the nonlinearity parameter of suspensions of ultrasound contrast agents (UCAs, also known as bubbly liquids) remains open. The present paper formulates a new equation based on the thermodynamic method that correlates both attenuation and phase velocity of linear ultrasound. The simplicity of the present method makes the B/A estimation possible with a relatively rigorous mathematical derivation. The calculated nonlinearity parameter contains the contribution of dynamic effects of bubbles, and its low-frequency limit agrees with B/A estimated by the method of mixture law when the volume fraction is below 10-4. Furthermore, the maximum B/A in bubbly liquids can reach up to105, while the minimum can be as low as -105. The negative nonlinearity parameter indicates significantly different thermodynamic properties of bubbly liquids.
Collapse
|
10
|
State-of-the-Art Preclinical Photoacoustic Imaging in Oncology: Recent Advances in Cancer Theranostics. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:5080267. [PMID: 31182936 PMCID: PMC6515147 DOI: 10.1155/2019/5080267] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 04/15/2019] [Indexed: 02/08/2023]
Abstract
The optical imaging plays an increasing role in preclinical studies, particularly in cancer biology. The combined ultrasound and optical imaging, named photoacoustic imaging (PAI), is an emerging hybrid technique for real-time molecular imaging in preclinical research and recently expanding into clinical setting. PAI can be performed using endogenous contrast, particularly from oxygenated and deoxygenated hemoglobin and melanin, or exogenous contrast agents, sometimes targeted for specific biomarkers, providing comprehensive morphofunctional and molecular information on tumor microenvironment. Overall, PAI has revealed notable opportunities to improve knowledge on tumor pathophysiology and on the biological mechanisms underlying therapy. The aim of this review is to introduce the principles of PAI and to provide a brief overview of current PAI applications in preclinical research, highlighting also on recent advances in clinical translation for cancer diagnosis, staging, and therapy.
Collapse
|
11
|
Photonic cancer nanomedicine using the near infrared-II biowindow enabled by biocompatible titanium nitride nanoplatforms. NANOSCALE HORIZONS 2019; 4:415-425. [PMID: 32254094 DOI: 10.1039/c8nh00299a] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Light-activated photoacoustic imaging (PAI) and photothermal therapy (PTT) using the second near-infrared biowindow (NIR-II, 1000-1350 nm) hold great promise for efficient tumor detection and diagnostic imaging-guided photonic nanomedicine. In this work, we report on the construction of titanium nitride (TiN) nanoparticles, with a high photothermal-conversion efficiency and desirable biocompatibility, as an alternative theranostic agent for NIR-II laser-excited photoacoustic (PA) imaging-guided photothermal tumor hyperthermia. Working within the NIR-II biowindow provides a larger maximum permissible exposure (MPE) and desirable penetration depth of the light, which then allows detection of the tumor to the full extent using PA imaging and complete tumor ablation using photothermal ablation, especially in deeper regions. After further surface polyvinyl-pyrrolidone (PVP) modification, the TiN-PVP photothermal nanoagents exhibited a high photothermal conversion efficiency of 22.8% in the NIR-II biowindow, and we further verified their high penetration depth using the NIR-II biowindow and their corresponding therapeutic effect on the viability of tumor cells in vitro. Furthermore, these TiN-PVP nanoparticles were developed as a contrast agent for NIR-II-activated PA imaging both in vitro and in vivo for the first time and realized efficient photothermal ablation of the tumor in vivo within both the NIR-I and NIR-II biowindows. This work not only provides a paradigm for TiN-PVP photothermal nanoagents working in the NIR-II biowindow both in vitro and in vivo, but also proves the feasibility of PAI and PTT cancer theranostics using NIR-II laser excitation.
Collapse
|
12
|
Abstract
BACKGROUND Commercially available microbubbles such as Definity contain octafluoropropane encapsulated in a lipid shell. This perfluorocarbon can be compressed into liquid nanodroplets at room temperatures and activated with transthoracic diagnostic ultrasound. The aim of this study was to determine the size range and acoustic characteristics of Definity nanodroplets (DNDs) compared with Definity microbubbles (DMBs). METHODS An in vitro flow system was used with a diagnostic ultrasound transducer (S5-1, iE33). DMBs were prepared using package insert instructions. DNDs were prepared by cooling DMBs in a -10°C to -15°C isopropyl alcohol bath before hand-pressurizing the solution. The formed DNDs were sized, diluted to 1% solutions, and infused continuously into a phosphate-buffered saline solution running within Silastic tubing. Acoustic intensity (AI) was compared with equivalent dilutions of DMBs at different mechanical indices (MIs) ranging from 0.2 to 1.4 (n = 6 comparisons at each MI) using real-time 56-Hz and triggered 2-Hz frame rates (FRs). A 3-cm-thick tissue-mimicking phantom was used to simulate transthoracic attenuation. In vivo transthoracic studies were performed in four normal pigs infused with 10% intravenous infusions of DMBs or DNDs at real-time and triggered end-systolic FRs to compare differences in myocardial and left ventricular cavity AI. RESULTS DNDs were smaller than DMBs and ranged in size from 50 to 1,000 nm. In vitro studies revealed that at an MI of 0.2 and an FR of 56 Hz, DMBs had high AI (37 ± 2 dB), but AI dropped to 25 ± 2 dB at an MI of 1.0 (P < .001, analysis of variance). In comparison, DNDs had virtually no AI at MIs of 0.2 to 0.6 at both triggered and 56-Hz FRs (1 ± 0 dB), but AI increased to 34 ± 2 dB at an MI of 1.4 using an FR of 56 Hz (P < .001 vs MI of 0.2). AI also persisted longer at 56 Hz with DNDs when using higher MIs. In vivo studies demonstrated higher myocardial AI for DNDs at higher MIs when using real-time FR, most likely from microvascular nanodroplet activation. CONCLUSION These data indicate significant differences in acoustic responses of the commercially available DMBs when administered as an equivalent number of DNDs. The DND formulation may render them more useful for high-MI real-time imaging and other targeted transthoracic diagnostic applications.
Collapse
|
13
|
Influence of temperature, needle gauge and injection rate on the size distribution, concentration and acoustic responses of ultrasound contrast agents at high frequency. ULTRASONICS 2016; 70:84-91. [PMID: 27140502 DOI: 10.1016/j.ultras.2016.04.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Revised: 02/16/2016] [Accepted: 04/16/2016] [Indexed: 06/05/2023]
Abstract
This paper investigated the influence of needle gauge (19G and 27G), injection rate (0.85ml·min(-1), 3ml·min(-1)) and temperature (room temperature (RT) and body temperature (BT)) on the mean diameter, concentration, acoustic attenuation, contrast to tissue ratio (CTR) and normalised subharmonic intensity (NSI) of three ultrasound contrast agents (UCAs): Definity, SonoVue and MicroMarker (untargeted). A broadband substitution technique was used to acquire the acoustic properties over the frequency range 17-31MHz with a preclinical ultrasound scanner Vevo770 (Visualsonics, Canada). Significant differences (P<0.001-P<0.05) between typical in vitro setting (19G needle, 3ml·min(-1) at RT) and typical in vivo setting (27G needle, 0.85ml·min(-1) at BT) were found for SonoVue and MicroMarker. Moreover we found that the mean volume-based diameter and concentration of both SonoVue and Definity reduced significantly when changing from typical in vitro to in vivo experimental set-ups, while those for MicroMarker did not significantly change. From our limited measurements of Definity, we found no significant change in attenuation, CTR and NSI with needle gauge. For SonoVue, all the measured acoustic properties (attenuation, CTR and NSI) reduced significantly when changing from typical in vitro to in vivo experimental conditions, while for MicroMarker, only the NSI reduced, with attenuation and CTR increasing significantly. These differences suggest that changes in physical compression and temperature are likely to alter the shell structure of the UCAs resulting in measureable and significant changes in the physical and high frequency acoustical properties of the contrast agents under typical in vitro and preclinical in vivo experimental conditions.
Collapse
|
14
|
Acoustic Cluster Therapy: In Vitro and Ex Vivo Measurement of Activated Bubble Size Distribution and Temporal Dynamics. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1145-1166. [PMID: 26831341 DOI: 10.1016/j.ultrasmedbio.2015.12.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Revised: 12/07/2015] [Accepted: 12/14/2015] [Indexed: 06/05/2023]
Abstract
Acoustic cluster technology (ACT) is a two-component, microparticle formulation platform being developed for ultrasound-mediated drug delivery. Sonazoid microbubbles, which have a negative surface charge, are mixed with micron-sized perfluoromethylcyclopentane droplets stabilized with a positively charged surface membrane to form microbubble/microdroplet clusters. On exposure to ultrasound, the oil undergoes a phase change to the gaseous state, generating 20- to 40-μm ACT bubbles. An acoustic transmission technique is used to measure absorption and velocity dispersion of the ACT bubbles. An inversion technique computes bubble size population with temporal resolution of seconds. Bubble populations are measured both in vitro and in vivo after activation within the cardiac chambers of a dog model, with catheter-based flow through an extracorporeal measurement flow chamber. Volume-weighted mean diameter in arterial blood after activation in the left ventricle was 22 μm, with no bubbles >44 μm in diameter. After intravenous administration, 24.4% of the oil is activated in the cardiac chambers.
Collapse
|
15
|
Investigating the stability of gadolinium based contrast agents towards UV radiation. WATER RESEARCH 2016; 91:244-50. [PMID: 26802476 DOI: 10.1016/j.watres.2016.01.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 01/05/2016] [Accepted: 01/08/2016] [Indexed: 05/28/2023]
Abstract
Since the 1980s, the broad application of gadolinium(Gd)-based contrast agents for magnetic resonance imaging (MRI) has led to significantly increased concentrations of Gd in the aqueous environment. Little is known about the stability of these highly polar xenobiotics under environmental conditions, in wastewater and in drinking water treatment. Therefore, the stability of frequently applied Gd-based MRI contrast agents towards UV radiation was investigated. The hyphenation of hydrophilic interaction liquid chromatography (HILIC) with inductively coupled plasma mass spectrometry (ICP-MS) and of HILIC with electrospray ionization mass spectrometry (ESI-MS) provided quantitative elemental information as well as structural information. The contrast agents Gd-DTPA, Gd-DOTA and Gd-BT-DO3A showed a high stability in irradiation experiments applying a wavelength range from 220 nm to 500 nm. Nevertheless, the degradation of Gd-BOPTA as well as the formation of Gd-containing transformation products was observed by means of HILIC-ICP-MS. Matrix-dependent irradiation experiments showed a degradation of Gd-BOPTA down to 3% of the initial amount in purified water after 300 min, whereas the degradation was slowed down in drinking water and surface water. Furthermore, it was observed that the sum of species continuously decreased with proceeding irradiation in all matrices. After irradiation in purified water for 300 min only 16% of the sum of species was left. This indicates a release of Gd(III) ions from the complex in course of irradiation. HILIC-ESI-MS measurements revealed that the transformation products mostly resulted from O-dealkylation and N-dealkylation reactions. In good correlation with retention times, the majority of transformation products were found to be more polar than Gd-BOPTA itself. Based on accurate masses, sum formulas were obtained and structures could be proposed.
Collapse
|
16
|
Image-Guided Ultrasound Characterization of Volatile Sub-Micron Phase-Shift Droplets in the 20-40 MHz Frequency Range. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:795-807. [PMID: 26725168 DOI: 10.1016/j.ultrasmedbio.2015.11.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 11/02/2015] [Accepted: 11/12/2015] [Indexed: 05/09/2023]
Abstract
Phase-shift perfluorocarbon droplets are designed to convert from the liquid to the gas state by the external application of acoustic or optical energy. Although droplet vaporization has been investigated extensively at ultrasonic frequencies between 1 and 10 MHz, few studies have characterized performance at the higher frequencies commonly used in small animal imaging. In this study, we use standard B-mode imaging sequences on a pre-clinical ultrasound platform to both image and activate sub-micron decafluorobutane droplet populations in vitro and in vivo at center frequencies in the range of 20-40 MHz. Results show that droplets remain stable against vaporization at low imaging pressures but are vaporized at peak negative pressures near 3.5 MPa at the three frequencies tested. This study also found that a small number of size outliers present in the distribution can greatly influence droplet performance. Removal of these outliers results in a more accurate assessment of the vaporization threshold and produces free-flowing microbubbles upon vaporization in the mouse kidney.
Collapse
|
17
|
Fluid Viscosity Affects the Fragmentation and Inertial Cavitation Threshold of Lipid-Encapsulated Microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:782-94. [PMID: 26674676 PMCID: PMC4744112 DOI: 10.1016/j.ultrasmedbio.2015.10.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 10/16/2015] [Accepted: 10/27/2015] [Indexed: 05/04/2023]
Abstract
Ultrasound and microbubble optimization studies for therapeutic applications are often conducted in water/saline, with a fluid viscosity of 1 cP. In an in vivo context, microbubbles are situated in blood, a more viscous fluid (∼4 cP). In this study, ultrahigh-speed microscopy and passive cavitation approaches were employed to investigate the effect of fluid viscosity on microbubble behavior at 1 MHz subject to high pressures (0.25-2 MPa). The propensity for individual microbubble (n = 220) fragmentation was found to significantly decrease in 4-cP fluid compared with 1-cP fluid, despite achieving similar maximum radial excursions. Microbubble populations diluted in 4-cP fluid exhibited decreased wideband emissions (up to 10.2 times), and increasingly distinct harmonic emission peaks (e.g., ultraharmonic) with increasing pressure, compared with those in 1-cP fluid. These results suggest that in vitro studies should consider an evaluation using physiologic viscosity perfusate before transitioning to in vivo evaluations.
Collapse
|
18
|
Influence of Guided Waves in Tibia on Non-linear Scattering of Contrast Agents. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:561-573. [PMID: 26617242 DOI: 10.1016/j.ultrasmedbio.2015.10.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 07/21/2015] [Accepted: 10/09/2015] [Indexed: 06/05/2023]
Abstract
The aim of this study was to elucidate the linear and non-linear responses of ultrasound contrast agent (UCA) to frequency-dispersive guided waves from the tibia cortex, particularly two individual modes, S0 (1.23 MHz) and A1 (2.06 MHz). The UCA responses to guided waves were illustrated through the Marmottant model derived from measured guided waves, and then verified by continuous infusion experiments in a vessel-tibia flow phantom. These UCA responses were further evaluated by the enhanced ratio of peak values and the resolutions of UCA backscattered echoes. Because of the individual modes S0 and A1 in the tibia, the peak values of the UCA backscattered echoes were enhanced by 83.57 ± 7.35% (p < 0.05) and 80.77 ± 6.60% (p < 0.01) in the UCA subharmonic frequency and subharmonic imaging, respectively. However, corresponding resolutions were 0.78 ± 0.07 (p < 0.05) and 0.72 ± 0.12 (p < 0.01) times those without guided wave disturbances, respectively. Even though the resolution was partly degenerated, the subharmonic detection sensitivity of UCA was improved by the guided waves. Thus, UCA responses to the double-frequency guided waves should be further explored to benefit the detection of capillary perfusion in tissue layers near the bone cortex, particularly for perfusion imaging in the free flaps and skeletal muscles.
Collapse
|
19
|
Dynamic Behavior of Microbubbles during Long Ultrasound Tone-Burst Excitation: Mechanistic Insights into Ultrasound-Microbubble Mediated Therapeutics Using High-Speed Imaging and Cavitation Detection. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:528-538. [PMID: 26603628 PMCID: PMC4698009 DOI: 10.1016/j.ultrasmedbio.2015.09.017] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Revised: 09/11/2015] [Accepted: 09/17/2015] [Indexed: 05/24/2023]
Abstract
Ultrasound (US)-microbubble (MB)-mediated therapies have been found to restore perfusion and enhance drug/gene delivery. On the presumption that MBs do not persist during long US exposure under high acoustic pressures, most schemes use short US pulses when a high US pressure is employed. However, we recently observed an enhanced thrombolytic effect using long US pulses at high acoustic pressures. Therefore, we explored the fate of MBs during long tone-burst exposures (5 ms) at various acoustic pressures and MB concentrations via direct high-speed optical observation and passive cavitation detection. MBs first underwent stable or inertial cavitation depending on the acoustic pressure and then formed gas-filled clusters that continued to oscillate, break up and form new clusters. Cavitation detection confirmed continued, albeit diminishing, acoustic activity throughout the 5-ms US excitation. These data suggest that persisting cavitation activity during long tone bursts may confer additional therapeutic effects.
Collapse
|
20
|
Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:518-27. [PMID: 26547633 PMCID: PMC4698006 DOI: 10.1016/j.ultrasmedbio.2015.08.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Revised: 08/12/2015] [Accepted: 08/21/2015] [Indexed: 05/11/2023]
Abstract
Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis.
Collapse
|
21
|
Implementation of a new scanning method for high-resolution fluorescence tomography using thermo-sensitive fluorescent agents. OPTICS LETTERS 2015; 40:4991-4. [PMID: 26512501 PMCID: PMC4890556 DOI: 10.1364/ol.40.004991] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Conventional fluorescence tomography provides images of the distribution of fluorescent agents within highly scattering media, but suffers from poor spatial resolution. Previously, we introduced a new method termed "temperature-modulated fluorescence tomography" (TM-FT) that generates fluorescence images with high spatial resolution. TM-FT first uses focused ultrasound to locate the distribution of temperature-sensitive fluorescence probes. Afterward, this a priori information is utilized to improve the performance of the inverse solver for conventional fluorescence tomography and reveal quantitatively accurate fluorophore concentration maps. However, the disadvantage of this novel method is the long data acquisition time as the ultrasound beam was scanned in a step-and-shoot mode. In this Letter, we present a new, fast scanning method that reduces the imaging time 40 fold. By continuously scanning the ultrasound beam over a 50 mm by 25 mm field-of-view, high-resolution fluorescence images are obtained in less than 29 min, which is critical for in vivo small animal imaging.
Collapse
|
22
|
Enhanced production of reactive oxygen species by gadolinium oxide nanoparticles under core-inner-shell excitation by proton or monochromatic X-ray irradiation: implication of the contribution from the interatomic de-excitation-mediated nanoradiator effect to dose enhancement. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2015; 54:423-431. [PMID: 26242374 DOI: 10.1007/s00411-015-0612-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2014] [Accepted: 07/26/2015] [Indexed: 06/04/2023]
Abstract
Core-inner-valence ionization of high-Z nanoparticle atomic clusters can de-excite electrons through various interatomic de-excitation processes, thereby leading to the ionization of both directly exposed atoms and adjacent neutral atoms within the nanoparticles, and to an enhancement in photon-electron emission, which is termed the nanoradiator effect. To investigate the nanoradiator-mediated dose enhancement in the radio-sensitizing of high-Z nanoparticles, the production of reactive oxygen species (ROS) was measured in a gadolinium oxide nanoparticle (Gd-oxide NP) solution under core-inner-valence excitation of Gd with either 50 keV monochromatic synchrotron X-rays or 45 MeV protons. This measurement was compared with either a radiation-only control or a gadolinium-chelate magnetic resonance imaging contrast agent solution containing equal amounts of gadolinium as the separate atomic species in which Gd-Gd interatomic de-excitations are absent. Ionization excitations followed by ROS measurements were performed on nanoparticle-loaded cells or aqueous solutions. Both photoexcitation and proton impact produced a dose-dependent enhancement in the production of ROS by a range of factors from 1.6 to 1.94 compared with the radiation-only control. Enhanced production of ROS, by a factor of 1.83, was observed from Gd-oxide NP atomic clusters compared with the Gd-chelate molecule, with a Gd concentration of 48 μg/mL in the core-level photon excitation, or by a factor of 1.82 under a Gd concentration of 12 μg/mL for the proton impact at 10 Gy (p < 0.02). The enhanced production of ROS in the irradiated nanoparticles suggests the potential for additional therapeutic dose enhancements in radiation treatment via the potent Gd-Gd interatomic de-excitation-driven nanoradiator effect.
Collapse
|
23
|
Quantifying activation of perfluorocarbon-based phase-change contrast agents using simultaneous acoustic and optical observation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1422-31. [PMID: 25656747 PMCID: PMC5706456 DOI: 10.1016/j.ultrasmedbio.2014.12.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 12/01/2014] [Accepted: 12/15/2014] [Indexed: 05/05/2023]
Abstract
Phase-change contrast agents in the form of nanoscale droplets can be activated into microbubbles by ultrasound, extending the contrast beyond the vasculature. This article describes simultaneous optical and acoustical measurements for quantifying the ultrasound activation of phase-change contrast agents over a range of concentrations. In experiments, decafluorobutane-based nanodroplets of different dilutions were sonicated with a high-pressure activation pulse and two low-pressure interrogation pulses immediately before and after the activation pulse. The differences between the pre- and post-interrogation signals were calculated to quantify the acoustic power scattered by the microbubbles activated over a range of droplet concentrations. Optical observation occurred simultaneously with the acoustic measurement, and the pre- and post-microscopy images were processed to generate an independent quantitative indicator of the activated microbubble concentration. Both optical and acoustic measurements revealed linear relationships to the droplet concentration at a low concentration range <10(8)/mL when measured at body temperature. Further increases in droplet concentration resulted in saturation of the acoustic interrogation signal. Compared with body temperature, room temperature was found to produce much fewer and larger bubbles after ultrasound droplet activation.
Collapse
|
24
|
Real-time feedback of histotripsy thrombolysis using bubble-induced color Doppler. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1386-401. [PMID: 25623821 PMCID: PMC4398659 DOI: 10.1016/j.ultrasmedbio.2014.12.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 11/25/2014] [Accepted: 12/10/2014] [Indexed: 05/06/2023]
Abstract
Histotripsy thrombolysis is a non-invasive, drug-free, image-guided therapy that fractionates blood clots using well-controlled acoustic cavitation alone. Real-time quantitative feedback is highly desired during histotripsy thrombolysis treatment to monitor the progress of clot fractionation. Bubble-induced color Doppler (BCD) monitors the motion after cavitation generated by each histotripsy pulse, which has been found in gel and ex vivo liver tissue to be correlated with histotripsy fractionation. We investigated the potential of BCD to quantitatively monitor histotripsy thrombolysis in real time. To visualize clot fractionation, transparent three-layered fibrin clots were developed. Results indicated that a coherent motion follows the cavitation generated by each histotripsy pulse with a push and rebound pattern. The temporal profile of this motion expands and saturates as treatment progresses. A strong correlation exists between the degree of histotripsy clot fractionation and two metrics extracted from BCD: time of peak rebound velocity (tPRV) and focal mean velocity at a fixed delay (Vf,delay). The saturation of clot fractionation (i.e., treatment completion) matches well the saturations detected using tPRV and Vf,delay. The mean Pearson correlation coefficients between the progression of clot fractionation and the two BCD metrics were 93.1% and 92.6%, respectively. To validate BCD feedback in in vitro clots, debris volumes from histotripsy thrombolysis were obtained at different therapy doses and compared with Vf,delay. There is also good agreement between the increasing and saturation trends of debris volume and Vf,delay. Finally, a real-time BCD feedback algorithm to predict complete clot fractionation during histotripsy thrombolysis was developed and tested. This work illustrates the potential of BCD to monitor histotripsy thrombolysis treatment in real time.
Collapse
|
25
|
Non-linear response and viscoelastic properties of lipid-coated microbubbles: DSPC versus DPPC. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1432-45. [PMID: 25724308 DOI: 10.1016/j.ultrasmedbio.2015.01.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Revised: 01/09/2015] [Accepted: 01/16/2015] [Indexed: 05/21/2023]
Abstract
For successful in vivo contrast-enhanced ultrasound imaging (CEUS) and ultrasound molecular imaging, detailed knowledge of stability and acoustical properties of the microbubbles is essential. Here, we compare these aspects of lipid-coated microbubbles that have either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) as their main lipid; the other components were identical. The microbubbles were investigated in vitro over the frequency range 1-4 MHz at pressures between 10 and 100 kPa, and their response to the applied ultrasound was recorded using ultrahigh-speed imaging (15 Mfps). Relative to DPPC-coated microbubbles, DSPC-coated microbubbles had (i) higher acoustical stability; (ii) higher shell elasticity as derived using the Marmottant model (DSPC: 0.26 ± 0.13 N/m, DPPC: 0.06 ± 0.06 N/m); (iii) pressure amplitudes twice as high at the second harmonic frequency; and (iv) a smaller amount of microbubbles that responded at the subharmonic frequency. Because of their higher acoustical stability and higher non-linear response, DSPC-coated microbubbles may be more suitable for contrast-enhanced ultrasound.
Collapse
|
26
|
808 nm driven Nd3+-sensitized upconversion nanostructures for photodynamic therapy and simultaneous fluorescence imaging. NANOSCALE 2015; 7:190-7. [PMID: 25406514 DOI: 10.1039/c4nr04953e] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The in vivo biological applications of upconversion nanoparticles (UCNPs) prefer excitation at 700-850 nm, instead of 980 nm, due to the absorption of water. Recent approaches in constructing robust Nd(3+) doped UCNPs with 808 nm excitation properties rely on a thick Nd(3+) sensitized shell. However, for the very important and popular Förster resonance energy transfer (FRET)-based applications, such as photodynamic therapy (PDT) or switchable biosensors, this type of structure has restrictions resulting in a poor energy transfer. In this work, we have designed a NaYF4:Yb/Ho@NaYF4:Nd@NaYF4 core-shell-shell nanostructure. We have proven that this optimal structure balances the robustness of the upconversion emission and the FRET efficiency for FRET-based bioapplications. A proof of the concept was demonstrated for photodynamic therapy and simultaneous fluorescence imaging of HeLa cells triggered by 808 nm light, where low heating and a high PDT efficacy were achieved.
Collapse
|
27
|
Ultrafast 2-dimensional image monitoring and array-based passive cavitation detection for ultrasound contrast agent destruction in a variably sized region. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2014; 33:1957-1970. [PMID: 25336483 DOI: 10.7863/ultra.33.11.1957] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVES A combined approach was proposed, based on programmable ultrasound equipment, to simultaneously monitor surviving microbubbles and detect cavitation activity during microbubble destruction in a variably sized region for use in ultrasound contrast agent (UCA)-enhanced therapeutic ultrasound applications. METHODS A variably sized focal region wherein the acoustic pressure was above the UCA fragmentation threshold was synthesized at frequencies of 3, 4, 5, and 6 MHz with a linear broadband imaging probe. The UCAs' temporal and spatial distribution during the microbubbles' destruction was monitored in a 2-dimensional imaging plane at 5 MHz and a frame rate of 400 Hz, and simultaneously, broadband noise emissions during the microbubbles' fragmentation were extracted by using the backscattered signals produced by the focused release bursts (ie, destruction pulses) themselves. Afterward, the temporal evolution of broadband noise emission, the surviving microbubbles in a region of interest (ROI), and the destruction area in a static UCA suspension were computed. Then the inertial cavitation dose, destruction rate of microbubbles in the ROI, and area of the destruction region were determined. RESULTS It was found that an increasing pulse length and a decreasing transmit aperture and excitation frequency were correlated with an increased inertial cavitation dose, microbubble destruction rate, and destruction area. Furthermore, it was obvious that the microbubble destruction rate was significantly correlated with the inertial cavitation dose (P < .05). In addition, the intensity decrease in the ROI was significantly correlated with the destruction area (P < .05). CONCLUSIONS By the proposed strategy, microbubbles could be destroyed in a variably sized region, and destruction efficiency as well as the corresponding inertial cavitation dose could be regulated by manipulating the transmission parameters.
Collapse
|
28
|
Ultrasound-modulated fluorescence based on fluorescent microbubbles. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:085005. [PMID: 25104407 PMCID: PMC4407672 DOI: 10.1117/1.jbo.19.8.085005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 07/09/2014] [Accepted: 07/14/2014] [Indexed: 05/15/2023]
Abstract
Ultrasound-modulated fluorescence (UMF) imaging has been proposed to provide fluorescent contrast while maintaining ultrasound resolution in an optical-scattering medium (such as biological tissue). The major challenge is to extract the weakly modulated fluorescent signal from a bright and unmodulated background. UMF was experimentally demonstrated based on fluorophore-labeled microbubble contrast agents. These contrast agents were produced by conjugating N-hydroxysuccinimide (NHS)-ester-attached fluorophores on the surface of amine-functionalized microbubbles. The fluorophore surface concentration was controlled so that a significant self-quenching effect occurred when no ultrasound was applied. The intensity of the fluorescent emission was modulated when microbubbles were oscillated by ultrasound pulses, presented as UMF signal. Our results demonstrated that the UMF signals were highly dependent on the microbubbles' oscillation amplitude and the initial surface fluorophore-quenching status. A maximum of ∼42% UMF modulation depth was achieved with a single microbubble under an ultrasound peak-to-peak pressure of 675 kPa. Further, UMF was detected from a 500-μm tube filled with contrast agents in water and scattering media with ultrasound resolution. These results indicate that ultrasound-modulated fluorescent microbubble contrast agents can potentially be used for fluorescence-based molecular imaging with ultrasound resolution in the future.
Collapse
|
29
|
Quantitative analysis of ultrasound contrast agent postexcitation collapse. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1237-1241. [PMID: 24960713 PMCID: PMC4123746 DOI: 10.1109/tuffc.2014.3023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
An empirically based peak-detection technique is described for statistically analyzing single ultrasound contrast agent collapses. It is shown that microbubbles with postexcitation collapse initially exhibit a stronger principal response on average than those without postexcitation, and that lower insonifying frequencies lead to postexcitation signals which have greater separation from their principal response and persist through more rebounds.
Collapse
|
30
|
(19)F spin-lattice relaxation of perfluoropolyethers: Dependence on temperature and magnetic field strength (7.0-14.1T). JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 242:18-22. [PMID: 24594752 PMCID: PMC4008704 DOI: 10.1016/j.jmr.2014.01.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2013] [Revised: 01/28/2014] [Accepted: 01/30/2014] [Indexed: 06/03/2023]
Abstract
Fluorine ((19)F) MRI of perfluorocarbon-labeled cells has become a powerful technique to track the migration and accumulation of cells in living organisms. It is common to label cells for (19)F MRI with nanoemulsions of perfluoropolyethers that contain a large number of chemically equivalent fluorine atoms. Understanding the mechanisms of (19)F nuclear relaxation, and in particular the spin-lattice relaxation of these molecules, is critical to improving experimental sensitivity. To date, the temperature and magnetic field strength dependence of spin-lattice relaxation rate constant (R1) for perfluoropolyethers has not been described in detail. In this study, we evaluated the R1 of linear perfluoropolyether (PFPE) and cyclic perfluoro-15-crown-5 ether (PCE) at three magnetic field strengths (7.0, 9.4, and 14.1T) and at temperatures ranging from 256-323K. Our results show that R1 of perfluoropolyethers is dominated by dipole-dipole interactions and chemical shift anisotropy. R1 increased with magnetic field strength for both PCE and PFPE. In the temperature range studied, PCE was in the fast motion regime (ωτc<1) at all field strengths, but for PFPE, R1 passed through a maximum, from which the rotational correlation time was estimated. The importance of these measurements for the rational design of new (19)F MRI agents and methods is discussed.
Collapse
|
31
|
The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:727-38. [PMID: 24582298 PMCID: PMC3997117 DOI: 10.1016/j.ultrasmedbio.2014.01.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Revised: 11/26/2013] [Accepted: 01/06/2014] [Indexed: 05/08/2023]
Abstract
Characterizing the non-linear response of microbubble contrast agents is important for their efficacious use in imaging and therapy. In this article, we report that the subharmonic and ultraharmonic response of lipid-shelled microbubble contrast agents exhibits a strong temporal dependence. We characterized non-linear emissions from Targestar-p microbubbles (Targeson Inc., San Diego, CA, USA) periodically for 60 min, at 10 MHz excitation frequency. The results revealed a considerable increase in the subharmonic and ultraharmonic response (nearly 12-15 and 5-8 dB) after 5-10 min of agent preparation. However, the fundamental and the harmonic response remained almost unchanged in this period. During the next 50 min, the subharmonic, fundamental, ultraharmonic, and harmonic responses decreased steadily by 2-5 dB. The temporal changes in the non-linear behavior of the agent appeared to be primarily mediated by gas-exchange through the microbubble shell; temperature and prior acoustic excitation based mechanisms were ruled out. Further, there was no measurable change in the agent size distribution by static diffusion. We envisage that these findings will help obtain reproducible measurements from agent characterization, non-linear imaging, and fluid-pressure sensing. These findings also suggest the possibility for improving non-linear imaging by careful design of ultrasound contrast agents.
Collapse
|
32
|
Characterization of acoustic droplet vaporization for control of bubble generation under flow conditions. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:551-61. [PMID: 24433748 DOI: 10.1016/j.ultrasmedbio.2013.10.020] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 10/20/2013] [Accepted: 10/21/2013] [Indexed: 05/14/2023]
Abstract
This study investigated the manipulation of bubbles generated by acoustic droplet vaporization (ADV) under clinically relevant flow conditions. Optical microscopy and high-frequency ultrasound imaging were used to observe bubbles generated by 2-MHz ultrasound pulses at different time points after the onset of ADV. The dependence of the bubble population on droplet concentration, flow velocity, fluid viscosity and acoustic parameters, including acoustic pressure, pulse duration and pulse repetition frequency, was investigated. The results indicated that post-ADV bubble growth spontaneously driven by air permeation markedly affected the bubble population after insonation. The bubbles can grow to a stable equilibrium diameter as great as twice the original diameter in 0.5-1 s, as predicted by the theoretical calculation. The growth trend is independent of flow velocity, but dependent on fluid viscosity and droplet concentration, which directly influence the rate of gas uptake by bubbles and the rate of gas exchange across the wall of the semipermeable tube containing the bubbles and, hence, the gas content of the host medium. Varying the acoustic pressure does not markedly change the formation of bubbles as long as the ADV thresholds of most droplets are reached. Varying pulse duration and pulse repetition frequency markedly reduces the number of bubbles. Lengthening pulse duration favors the production of large bubbles, but reduces the total number of bubbles. Increasing the PRF interestingly provides superior performance in bubble disruption. These results also suggest that an ADV bubble population cannot be assessed simply on the basis of initial droplet size or enhancement of imaging contrast by the bubbles. Determining the optimal acoustic parameters requires careful consideration of their impact on the bubble population produced for different application scenarios.
Collapse
|
33
|
In vitro acoustic characterization of three phospholipid ultrasound contrast agents from 12 to 43 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:541-50. [PMID: 24361219 PMCID: PMC3923973 DOI: 10.1016/j.ultrasmedbio.2013.10.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Revised: 10/09/2013] [Accepted: 10/13/2013] [Indexed: 05/13/2023]
Abstract
The acoustic properties of two clinical (Definity, Lantheus Medical Imaging, North Billerica, MA, USA; SonoVue, Bracco S.P.A., Milan, Italy) and one pre-clinical (MicroMarker, untargeted, Bracco, Geneva, Switzerland; VisualSonics, Toronto, ON, Canada) ultrasound contrast agent were characterized using a broadband substitution technique over the ultrasound frequency range 12-43 MHz at 20 ± 1°C. At the same number concentration, the acoustic attenuation and contrast-to-tissue ratio of the three native ultrasound contrast agents are comparable at frequencies below 30 MHz, though their size distributions and encapsulated gases and shells differ. At frequencies above 30 MHz, native MicroMarker has higher attenuation values and contrast-to-tissue ratios than native Definity and SonoVue. Decantation was found to be an effective method to alter the size distribution and concentration of native clinical microbubble populations, enabling further contrast enhancement for specific pre-clinical applications.
Collapse
|
34
|
Concomitance in single bubble sonoluminescence of period doubling in emission and shape distortion. ULTRASONICS 2014; 54:637-643. [PMID: 24074749 DOI: 10.1016/j.ultras.2013.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Revised: 08/30/2013] [Accepted: 09/01/2013] [Indexed: 06/02/2023]
Abstract
We report the first direct observation for a single stable sonoluminescing bubble of a shape instability. Furthermore we show that stable saturation of the shape distortion caused by the instability for a certain range of parameters is experimentally possible and furthermore is directly linked to the curious phenomenon of flash by flash period doubling of the sonoluminescent emission as the afterbounce instability causing the shape distortion is always period doubled whenever the emission is & vice versa.
Collapse
|
35
|
High-frequency (20 to 40 MHz) acoustic response of liquid-filled nanocapsules. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:5-15. [PMID: 24402891 DOI: 10.1109/tuffc.2014.6689771] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Liquid-core nanoparticles are promising candidates for targeted ultrasound-controlled therapy, but their acoustic detection remains challenging. High-frequency (20 to 40 MHz) tone burst sequences were implemented with a programmable ultrasound biomicroscope to characterize acoustic response from perfluorooctyl bromide-core nanoparticles with thick poly(lactide-coglycolide) (PLGA) shells. Radio-frequency signals were acquired from flowing solutions of nanoparticles with two different shell-thickness-to-particle-radius ratios, solid PLGA nanoparticles, and latex nanobeads (linear controls). Normalized fundamental (20 MHz) and second-harmonic power spectral density (PSD) increased with particle concentration and was highest for the thinnest shelled particles. The second- harmonic PSD was detectable from the nanoparticles for peak rarefactional pressures (PRP) from 0.97 to 2.01 MPa at 23 cycles and for tone bursts from 11 to 23 cycles at 2.01 MPa. Their second-harmonic¿to¿fundamental ratio increased as a function of PRP and number of cycles. Within the same PRP and cycle ranges, the second-harmonic¿to¿fundamental ratios from matched concentration solutions of latex nanobeads and solid PLGA nanoparticles was more weakly detectable but also increased with PRP and number of cycles. Nanoparticles were detectable under flow conditions in vitro using the contrast agent mode of a high-frequency commercial scanner. These results characterize linear acoustic response from the nanoparticles (20 to 40 MHz) and demonstrate potential for their highfrequency detection.
Collapse
|
36
|
Single-particle optical sizing of microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:138-147. [PMID: 24139917 DOI: 10.1016/j.ultrasmedbio.2013.08.018] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Revised: 08/20/2013] [Accepted: 08/25/2013] [Indexed: 06/02/2023]
Abstract
Single-particle optical sizing techniques are being used to determine the size distributions of microbubble ultrasound contrast agents and to study the dynamics of individual microbubbles during ultrasound stimulation. The goal of this study was to compare experimental light obscuration and scattering measurements of microbubble size distributions with predictions from generalized Lorenz-Mie scattering theory (GLMT). First, we illustrate that a mono-modal size distribution can be misrepresented by single-particle light obscuration measurements as multi-modal peaks because of non-linearities in the extinction cross section-versus-diameter curve. Next, polymer bead standards are measured to provide conversion factors between GLMT calculations and experimental flow cytometry scatter plots. GLMT calculations with these conversion factors accurately predict the characteristic Lissajous-like serpentine scattering plot measured by flow cytometry for microbubbles. We conclude that GLMT calculations can be combined with optical forward and side scatter measurements to accurately determine microbubble size.
Collapse
|
37
|
Quantitative guidelines for the prediction of ultrasound contrast agent destruction during injection. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1838-1847. [PMID: 23849383 DOI: 10.1016/j.ultrasmedbio.2013.04.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2012] [Revised: 04/08/2013] [Accepted: 04/21/2013] [Indexed: 06/02/2023]
Abstract
Experiments and theory were undertaken on the destruction of ultrasound contrast agent microbubbles on needle injection, with the aim of predicting agent loss during in vivo studies. Agents were expelled through a variety of syringe and needle combinations, subjecting the microbubbles to a range of pressure drops. Imaging of the bubbles identified cases where bubbles were destroyed and the extent of destruction. Fluid-dynamic calculations determined the pressure drop for each syringe and needle combination. It was found that agent destruction occurred at a critical pressure drop that depended only on the type of microbubble. Protein-shelled microbubbles (sonicated bovine serum albumin) were virtually all destroyed above their critical pressure drop of 109 ± 7 kPa Two types of lipid-shelled microbubbles were found to have a pressure drop threshold above which more than 50% of the microbubbles were destroyed. The commercial lipid-shelled agent Definity was found to have a critical pressure drop for destruction of 230 ± 10 kPa; for a previously published lipid-shelled agent, this value was 150 ± 40 kPa. It is recommended that attention to the predictions of a simple formula could preclude unnecessary destruction of microbubble contrast agent during in vivo injections. This approach may also preclude undesirable release of drug or gene payloads in targeted microbubble therapies. Example values of appropriate injection rates for various agents and conditions are given.
Collapse
|
38
|
Echo-power estimation from log-compressed video data in dynamic contrast-enhanced ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1826-1837. [PMID: 23879926 DOI: 10.1016/j.ultrasmedbio.2013.03.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 03/20/2013] [Accepted: 03/21/2013] [Indexed: 06/02/2023]
Abstract
Ultrasound (US) scanners typically apply lossy, non-linear modifications to the US data for visualization purposes. The resulting images are then stored as compressed video data. Some system manufacturers provide dedicated software for quantification purposes to eliminate such processing distortions, at least partially. This is currently the recommended approach for quantitatively assessing changes in contrast-agent concentration from clinical data. However, the machine-specific access to US data and the limited set of analysis functionalities offered by each dedicated-software package make it difficult to perform comparable analyses with different US systems. The objective of this work was to establish if linearization of compressed video images obtained with an arbitrary US system can provide an alternative to dedicated-software analysis of machine-specific files for the estimation of echo-power. For this purpose, an Aplio 50 system (Toshiba Medical Systems, Tochigi, Japan), coupled with dedicated CHI-Q (Contrast Harmonic Imaging Quantification) software by Toshiba Medical Systems, was used. Results were compared with two approaches that apply algorithms to estimate relative echo-power from compressed video images: commercially available VueBox software by Bracco Suisse SA (Geneva, Switzerland) and in-laboratory software called PixPower. The echo-power estimated by CHI-Q analysis indicated a strong linear relationship versus agent concentration in vitro (R(2) ≥ 0.9996) for dynamic range (DR) settings of DR60 and DR80, with slopes between 9.22 and 9.57 dB/decade (p = 0.05). These values approach the theoretically predicted dependence of 10.0 dB/decade (equivalent to 3 dB for each concentration doubling). Echo-power estimations obtained from compressed video images with VueBox and PixPower also exhibited strong linear proportionality with concentration (R(2) ≥ 0.9996), with slopes between 9.30 and 9.68 dB/decade (p = 0.05). On an independent in vivo data set (N = 24), the difference in echo-power estimation between CHI-Q and each of the other two approaches was calculated after excluding regions that contain pixels affected by saturated or thresholded pixel values. The mean difference in estimates (expressed in decibels) was -0.25 dB between VueBox and CHI-Q (95% confidence interval: -0.75 to 0.26 dB) and -0.17 dB between PixPower and CHI-Q (95% confidence interval: -0.67 to 0.13 dB). To achieve linearization of data, one of the approaches (VueBox) requires calibration files provided by the software manufacturer for each machine type and setting. The other (PixPower) requires empirical correction of the imaging dynamic range based on ground truth data. These requirements could potentially be removed if US system manufacturers were willing to make relevant information on the applied processing publically available. Reliable echo-power estimation from linearized data would facilitate inclusion of different US systems in multicentric studies and more widespread implementation of emerging techniques for quantitative analysis of contrast ultrasound.
Collapse
|
39
|
In vivo demonstration of cancer molecular imaging with ultrasound radiation force and buried-ligand microbubbles. Mol Imaging 2013; 12:357-363. [PMID: 23981781 PMCID: PMC4494687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023] Open
Abstract
In designing targeted contrast agent materials for imaging, the need to present a targeting ligand for recognition and binding by the target is counterbalanced by the need to minimize interactions with plasma components and to avoid recognition by the immune system. We have previously reported on a microbubble imaging probe for ultrasound molecular imaging that uses a buried-ligand surface architecture to minimize unwanted interactions and immunogenicity. Here we examine for the first time the utility of this approach for in vivo molecular imaging. In accordance with previous results, we showed a threefold increase in circulation persistence through the tumor of a fibrosarcoma model in comparison with controls. The buried-ligand microbubbles were then activated for targeted adhesion through the application of noninvasive ultrasound radiation forces applied specifically to the tumor region. Using a clinical ultrasound scanner, microbubbles were activated, imaged, and silenced. The results showed visually conspicuous images of tumor neovasculature and a twofold increase in ultrasound radiation force enhancement of acoustic contrast intensity for buried-ligand microbubbles, whereas no such increase was found for exposed-ligand microbubbles. We therefore conclude that the use of acoustically active buried-ligand microbubbles for ultrasound molecular imaging bridges the demand for low immunogenicity with the necessity of maintaining targeting efficacy and imaging conspicuity in vivo.
Collapse
|
40
|
A microwave-assisted solution combustion synthesis to produce europium-doped calcium phosphate nanowhiskers for bioimaging applications. Acta Biomater 2013; 9:8422-32. [PMID: 23764803 DOI: 10.1016/j.actbio.2013.05.033] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2012] [Revised: 05/22/2013] [Accepted: 05/30/2013] [Indexed: 01/13/2023]
Abstract
Biocompatible nanoparticles possessing fluorescent properties offer attractive possibilities for multifunctional bioimaging and/or drug and gene delivery applications. Many of the limitations with current imaging systems center on the properties of the optical probes in relation to equipment technical capabilities. Here we introduce a novel high aspect ratio and highly crystalline europium-doped calcium phosphate nanowhisker produced using a simple microwave-assisted solution combustion synthesis method for use as a multifunctional bioimaging probe. X-ray diffraction confirmed the material phase as europium-doped hydroxyapatite. Fluorescence emission and excitation spectra and their corresponding peaks were identified using spectrofluorimetry and validated with fluorescence, confocal and multiphoton microscopy. The nanowhiskers were found to exhibit red and far red wavelength fluorescence under ultraviolet excitation with an optimal peak emission of 696 nm achieved with a 350 nm excitation. Relatively narrow emission bands were observed, which may permit their use in multicolor imaging applications. Confocal and multiphoton microscopy confirmed that the nanoparticles provide sufficient intensity to be utilized in imaging applications.
Collapse
|
41
|
Determination of the interfacial rheological properties of a poly(DL-lactic acid)-encapsulated contrast agent using in vitro attenuation and scattering. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1277-91. [PMID: 23643050 PMCID: PMC3674163 DOI: 10.1016/j.ultrasmedbio.2013.02.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2012] [Revised: 02/06/2013] [Accepted: 02/11/2013] [Indexed: 05/22/2023]
Abstract
The stabilizing encapsulation of a microbubble-based ultrasound contrast agent (UCA) critically affects its acoustic properties. Polymers, which behave differently from materials commonly used (i.e., lipids or proteins) for monolayer encapsulation, have the potential for better stability and improved control of encapsulation properties. Air-filled microbubbles coated with poly(DL-lactic acid) (PLA) are characterized here using in vitro acoustic experiments and several models of encapsulation. The interfacial rheological properties of the encapsulation are determined according to each model using attenuation of ultrasound through a suspension of microbubbles. Then the model predictions are compared with scattered non-linear (sub- and second harmonic) responses. For this microbubble population (average diameter, 1.9 μm), the peak in attenuation measurement indicates a weighted-average resonance frequency of 2.5-3 MHz, which, in contrast to other encapsulated microbubbles, is lower than the resonance frequency of a free bubble of similar size (diameter, 1.9 μm). This apparently contradictory result stems from the extremely low surface dilational elasticity (around 0.01-0.07 N/m) and the reduced surface tension of the poly(DL-lactic acid) encapsulation, as well as the polydispersity of the bubble population. All models considered here are shown to behave similarly even in the non-linear regime because of the low surface dilational elasticity value. Pressure-dependent scattering measurements at two different excitation frequencies (2.25 and 3 MHz) revealed strongly non-linear behavior with 25-30 dB and 5-20 dB enhancements in fundamental and second-harmonic responses, respectively, for a contrast agent concentration of 1.33 μg/mL in the suspension. Sub-harmonic responses are registered above a relatively low generation threshold of 100-150 kPa, with up to 20 dB enhancement beyond that pressure. Numerical predictions from all models show good agreement with the experimentally measured fundamental response, but not with the experimental second-harmonic response. The characteristic features of sub-harmonic responses and the steady response beyond the threshold are matched well by model predictions. However, prediction of the threshold value depends on estimated properties and size distribution. The variation in size distribution from sample to sample leads to variation in estimates of encapsulation properties: the lowest estimated value for surface dilational viscosity better predicts the sub-harmonic threshold.
Collapse
|
42
|
Influence of shell composition on the resonance frequency of microbubble contrast agents. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1292-302. [PMID: 23683409 DOI: 10.1016/j.ultrasmedbio.2013.02.462] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2011] [Revised: 02/22/2013] [Accepted: 02/24/2013] [Indexed: 05/12/2023]
Abstract
The effect of variations in microbubble shell composition on microbubble resonance frequency is revealed through experiment. These variations are achieved by altering the mole fraction and molecular weight of functionalized polyethylene glycol (PEG) in the microbubble phospholipid monolayer shell and measuring the microbubble resonance frequency. The resonance frequency is measured via a chirp pulse and identified as the frequency at which the pressure amplitude loss of the ultrasound wave is the greatest as a result of passing through a population of microbubbles. For the shell compositions used herein, we find that PEG molecular weight has little to no influence on resonance frequency at an overall PEG mole fraction (0.01) corresponding to a mushroom regime and influences the resonance frequency markedly at overall PEG mole fractions (0.050-0.100) corresponding to a brush regime. Specifically, the measured resonance frequency was found to be 8.4, 4.9, 3.3 and 1.4 MHz at PEG molecular weights of 1000, 2000, 3000 and 5000 g/mol, respectively, at an overall PEG mole fraction of 0.075. At an overall PEG mole fraction of just 0.01, on the other hand, resonance frequency exhibited no systematic variation, with values ranging from 5.7 to 4.9 MHz. Experimental results were analyzed using the Sarkar bubble dynamics model. With the dilatational viscosity held constant (10(-8) N·s/m) and the elastic modulus used as a fitting parameter, model fits to the pressure amplitude loss data resulted in elastic modulus values of 2.2, 2.4, 1.6 and 1.8 N/m for PEG molecular weights of 1000, 2000, 3000 and 5000 g/mol, respectively, at an overall PEG mole fraction of 0.010 and 4.2, 1.4, 0.5 and 0.0 N/m, respectively, at an overall PEG mole fraction of 0.075. These results are consistent with theory, which predicts that the elastic modulus is constant in the mushroom regime and decreases with PEG molecular weight to the inverse 3/5 power in the brush regime. Additionally, these results are consistent with inertial cavitation studies, which revealed that increasing PEG molecular weight has little to no effect on inethe rtial cavitation threshold in the mushroom regime, but that increasing PEG molecular weight decreases inertial cavitation markedly in the brush regime. We conclude that the design and synthesis of microbubbles with a prescribed resonance frequency is attainable by tuning PEG composition and molecular weight.
Collapse
|
43
|
The effect of binding on the subharmonic emissions from individual lipid-encapsulated microbubbles at transmit frequencies of 11 and 25 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:345-359. [PMID: 23219039 DOI: 10.1016/j.ultrasmedbio.2012.09.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2012] [Revised: 09/12/2012] [Accepted: 09/13/2012] [Indexed: 06/01/2023]
Abstract
Targeted microbubble imaging at ultrasound frequencies above 5 MHz has applications in both a preclinical context for a range of disease processes and clinically for the assessment of atherosclerosis and superficial tumors. Although the feasibility of ultrasound molecular imaging has been well demonstrated for a range of target molecules, little work has examined the effects of binding on microbubble oscillations, which is of potential relevance to improving the sensitivity, specificity, and quantification of bound-bubble detection. In this study we investigated the influence of binding on the subharmonic response of bubbles at transmit frequencies of 11 and 25 MHz. Individual bubbles were situated adjacent to a boundary in either a bound or an unbound state, optically sized and acoustically interrogated with pressures ranging from 0.02 to 1.2 MPa. At 11 MHz, unbound bubbles (n = 53) were found to have strong subharmonic activity for sizes between 2.4 and 2.6 μm, whereas bound bubbles (n = 50) were most active from 2.6 to 3.0 μm. Destruction thresholds were found to be lower for bound bubbles. At 25 MHz, bound-bubble (n = 57) activity was found to peak at 1.9 μm as compared to 2.1 μm in the unbound cases (n = 53), with a 20% increase in amplitude. Comparison with simulations indicates that both unbound and bound bubbles undergo compression-only behavior at 11 MHz, and expansion-dominated behavior at 25 MHz. Subharmonic emissions elicited from 0 radian transmit pulses were found to be π/2 radians out of phase with those elicited from a π radian transmit pulse, suggesting inefficient subharmonic preservation from pulse inversion schemes. With the appropriate postprocessed phase correction, an increase in the subharmonic amplitude of up to 60% was shown, depending on the bubble size and transmit frequency.
Collapse
|
44
|
Removal of iopromide and degradation characteristics in electron beam irradiation process. JOURNAL OF HAZARDOUS MATERIALS 2012; 227-228:126-34. [PMID: 22647234 DOI: 10.1016/j.jhazmat.2012.05.022] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2012] [Revised: 05/04/2012] [Accepted: 05/05/2012] [Indexed: 05/15/2023]
Abstract
The aim of this study is to evaluate the removal efficiency of iopromide using electron beam (E-beam) irradiation technology, and its degradation characteristics with hydroxyl radical (OH) and hydrated electron (e(aq)(-)). Studies are conducted with different initial concentrations of iopromide in pure water and in the presence of hydrogen peroxide, bicarbonate ion, or sulfite ion. E-beam absorbed dose of 19.6 kGy was required to achieve 90% degradation of 100 μM iopromide and the E-beam/H(2)O(2) system increased the removal efficiency by an amount of OH· generation. In the presence of OH scavengers (10 mM sulfite ion), the required dose for 90% removal of 100 μM iopromide was only 0.9 kGy. This greatly enhanced removal was achieved in the presence of OH· scavengers, which was rather unexpected and unlike the results obtained from most advanced oxidation process (AOP) experiments. The reasons for this enhancement can be explained by a kinetic study using the bimolecular rate constants of each reaction species. To explore the reaction scheme of iopromide with OH· or e(aq)(-) and the percent of mineralization for the two reaction paths, the total organic carbon (TOC), released iodide, and intermediates were analyzed.
Collapse
|
45
|
The effect of preactivation vial temperature on the acoustic properties of Definity™. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1298-305. [PMID: 22502892 DOI: 10.1016/j.ultrasmedbio.2012.03.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 03/01/2012] [Accepted: 03/04/2012] [Indexed: 05/21/2023]
Abstract
Definity™ is a widely available clinically approved ultrasound contrast agent. The manufacturer's instructions indicate that the refrigerated vial should be allowed to reach room temperature prior to its 45 s mechanical agitation activation process. Activation results in vial heating and it has been previously observed that "smaller" bubbles are formed later in this process (>10 s) when the vial temperature is elevated. The objective of this work was to examine the effects of preactivation vial temperature on the size distribution, frequency dependent attenuation (1.5-27 MHz) and nonlinear imaging performance of Definity™. Experiments were conducted with vials at refrigerator temperature (2°C), room temperature (22°C) or 37°C at the outset of the activation procedure. The size distributions were found to be strongly dependent on preactivation vial temperature and the attenuation results indicated considerable differences in the frequency response of the agent, most notably the appearance of a peak at 4 MHz for the 2°C case. Nonlinear imaging results performed using a 1-5 MHz transducer probe with a wall-less vessel phantom indicated that 2°C vials produced a signal enhancement 5.1 dB greater than for 22°C Definity™ (p < 0.05). These results, therefore, indicate that not permitting the vial to reach room temperature has a considerable impact on the imaging performance of Definity™. Conversely, activating a cooled vial can provide a means by which to improve contrast enhancement when using low frequency clinical transducers.
Collapse
|
46
|
In vitro sonothrombolysis of human blood clots with BR38 microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1222-1233. [PMID: 22542261 DOI: 10.1016/j.ultrasmedbio.2012.02.023] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 02/22/2012] [Accepted: 02/23/2012] [Indexed: 05/31/2023]
Abstract
Microbubble-mediated sonothrombolysis is a promising approach for ischemic stroke treatment. The aim of this in vitro study was to evaluate a new microbubble (MB) formulation (BR38) for sonothrombolysis and to investigate the involved mechanisms. Human whole-blood clots were exposed to different combinations of recombinant tissue plasminogen activator (rtPA), ultrasound (US) and MB. Ultrasound at 1.6 MHz was used at 150, 300, 600 and 1000 kPa (peak-negative pressure). Thrombolysis efficacy was assessed by measuring clot diameter changes during 60-min US exposure. The rate of clot diameter loss (RDL) in μm/min was determined and clot lysis profiles were analyzed. The most efficient clot lysis (5.9 μm/min) was obtained at acoustic pressures of 600 and 1000 kPa in combination with MB and a low concentration of rtPA (0.3 μg/mL). This is comparable with the rate obtained with rtPA at 3 μg/mL alone (6.6 μm/min, p > 0.05). Clot lysis profiles were shown to be related to US beam profiles and microbubble cavitation.
Collapse
|
47
|
Theoretical and experimental characterisation of magnetic microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:864-875. [PMID: 22480944 DOI: 10.1016/j.ultrasmedbio.2012.01.027] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 01/26/2012] [Accepted: 01/27/2012] [Indexed: 05/31/2023]
Abstract
In addition to improving image contrast, microbubbles have shown great potential in molecular imaging and drug/gene delivery. Previous work by the authors showed that considerable improvements in gene transfection efficiency were obtained using microbubbles loaded with magnetic nanoparticles under simultaneous exposure to ultrasound and magnetic fields. The aim of this study was to characterise the effect of nanoparticles on the dynamic and acoustic response of the microbubbles. High-speed video microscopy indicated that the amplitude of oscillation was very similar for magnetic and nonmagnetic microbubbles of the same size for the same ultrasound exposure (0.5 MHz, 100 kPa, 12-cycle pulse) and that this was minimally affected by an imposed magnetic field. The linear scattering to attenuation ratio (STAR) was also similar for suspensions of both bubble types although the nonlinear STAR was ~50% lower for the magnetic microbubbles. Both the video and acoustic data were supported by the results from theoretical modelling.
Collapse
|
48
|
Investigating the subharmonic response of individual phospholipid encapsulated microbubbles at high frequencies: a comparative study of five agents. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:846-63. [PMID: 22402024 DOI: 10.1016/j.ultrasmedbio.2012.01.011] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Revised: 01/01/2012] [Accepted: 01/13/2012] [Indexed: 05/21/2023]
Abstract
There are a range of contrast ultrasound applications above 10 MHz, a frequency regime in which nonlinear microbubble behavior is poorly understood. Lipid-encapsulated microbubbles have considerable potential for use at higher frequencies because they have been shown to exhibit pronounced nonlinear activity at frequencies up to 40 MHz. The objective of this work was to investigate the influence of agent formulation on the subharmonic response of lipid-encapsulated microbubbles at high frequencies with a view to providing information relevant to improving contrast agent design and imaging performance. An optical-acoustical setup was used to measure the subharmonic emissions from small (d < 3 μm) individual lipid-encapsulated microbubbles as a function of transmit pressure, size and composition. In this study, five agent formulations (Definity™, MicroMarker™ and three in-house agents manipulated to exhibit different levels of shell microstructure heterogeneity) were insonified at 25 MHz over a peak negative pressure (P(n)) range of 0.02-1.2 MPa. All agents exhibited distinctly different subharmonic behavior, both in terms of amplitude and active sizes. MicroMarker™ exhibited the strongest, broadest and most consistent subharmonic response, 22% greater in power than that of Definity™ and as much as 50% greater than the in-house formulations. No clear relation between in-house agents' shell microstructure and nonlinear response was found, other than the variability in the nonlinear response itself. An analysis of the response of MicroMarker™ bubbles suggests that these bubbles exhibit "expansion-dominated" oscillations, in contrast to "compression-only" oscillations observed for similar bubbles at lower frequencies (f < 11 MHz).
Collapse
|
49
|
Design of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons. Biomaterials 2012; 33:3262-9. [PMID: 22289265 PMCID: PMC3291020 DOI: 10.1016/j.biomaterials.2012.01.021] [Citation(s) in RCA: 163] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2011] [Accepted: 01/09/2012] [Indexed: 02/06/2023]
Abstract
Recently, an interest has developed in designing biomaterials for medical ultrasonics that can provide the acoustic activity of microbubbles, but with improved stability in vivo and a smaller size distribution for extravascular interrogation. One proposed alternative is the phase-change contrast agent. Phase-change contrast agents (PCCAs) consist of perfluorocarbons (PFCs) that are initially in liquid form, but can then be vaporized with acoustic energy. Crucial parameters for PCCAs include their sensitivity to acoustic energy, their size distribution, and their stability, and this manuscript provides insight into the custom design of PCCAs for balancing these parameters. Specifically, the relationship between size, thermal stability and sensitivity to ultrasound as a function of PFC boiling point and ambient temperature is illustrated. Emulsion stability and sensitivity can be 'tuned' by mixing PFCs in the gaseous state prior to condensation. Novel observations illustrate that stable droplets can be generated from PFCs with extremely low boiling points, such as octafluoropropane (b.p. -36.7 °C), which can be vaporized with acoustic parameters lower than previously observed. Results demonstrate the potential for low boiling point PFCs as a useful new class of compounds for activatable agents, which can be tailored to the desired application.
Collapse
|
50
|
Activation of microbubbles by short-pulsed ultrasound enhances the cytotoxic effect of cis-diamminedichloroplatinum (II) in a canine thyroid adenocarcinoma cell line in vitro. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:109-118. [PMID: 22104534 DOI: 10.1016/j.ultrasmedbio.2011.09.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2011] [Revised: 09/15/2011] [Accepted: 09/29/2011] [Indexed: 05/31/2023]
Abstract
Ultrasound targeted microbubble destruction has succeeded in delivering drugs and genes. This study was designed to explore characteristics of ultrasound targeted microbubble destruction using short-pulsed diagnostic ultrasound. Canine thyroid adenocarcinoma cells were exposed to short-pulsed diagnostic ultrasound in the presence of cis-diamminedichloroplatinum (II) (cisplatin) and ultrasound contrast agent Sonazoid(®) microbubbles. The cytotoxic effect of cisplatin was enhanced by short-pulsed diagnostic ultrasound and microbubbles. Incubation time with microbubbles influenced the cytotoxic effect of cisplatin. However, exposure duration did not affect the cytotoxic effect of cisplatin. Therefore, short-pulsed diagnostic ultrasound may activate microbubbles near cells and deliver cisplatin into cells. In addition, activation of microbubbles may be concluded in a short time. Our results suggest that short exposure duration could be potentially sufficient to induce efficient drug delivery by ultrasound targeted microbubble destruction using short-pulsed diagnostic ultrasound.
Collapse
|