1
|
Bäcklin E, Gonon A, Sköld M, Smedby Ö, Breznik E, Janerot-Sjoberg B. Pulmonary volumes and signs of chronic airflow limitation in quantitative computed tomography. Clin Physiol Funct Imaging 2024; 44:340-348. [PMID: 38576112 DOI: 10.1111/cpf.12880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 03/11/2024] [Accepted: 03/22/2024] [Indexed: 04/06/2024]
Abstract
BACKGROUND Computed tomography (CT) offers pulmonary volumetric quantification but is not commonly used in healthy individuals due to radiation concerns. Chronic airflow limitation (CAL) is one of the diagnostic criteria for chronic obstructive pulmonary disease (COPD), where early diagnosis is important. Our aim was to present reference values for chest CT volumetric and radiodensity measurements and explore their potential in detecting early signs of CAL. METHODS From the population-based Swedish CArdioPulmonarybioImage Study (SCAPIS), 294 participants aged 50-64, were categorized into non-CAL (n = 258) and CAL (n = 36) groups based on spirometry. From inspiratory and expiratory CT images we compared lung volumes, mean lung density (MLD), percentage of low attenuation volume (LAV%) and LAV cluster volume between groups, and against reference values from static pulmonary function test (PFT). RESULTS The CAL group exhibited larger lung volumes, higher LAV%, increased LAV cluster volume and lower MLD compared to the non-CAL group. Lung volumes significantly deviated from PFT values. Expiratory measurements yielded more reliable results for identifying CAL compared to inspiratory. Using a cut-off value of 0.6 for expiratory LAV%, we achieved sensitivity, specificity and positive/negative predictive values of 72%, 85% and 40%/96%, respectively. CONCLUSION We present volumetric reference values from inspiratory and expiratory chest CT images for a middle-aged healthy cohort. These results are not directly comparable to those from PFTs. Measures of MLD and LAV can be valuable in the evaluation of suspected CAL. Further validation and refinement are necessary to demonstrate its potential as a decision support tool for early detection of COPD.
Collapse
|
2
|
Heyer JH, Wisch JL, Nagra KK, Thakur A, Hillstrom HJ, Groisser BN, Zucker CP, Cunningham ME, Hresko MT, Haddas R, Blanco JS, Di Maio MF, Widmann RF. Novel Surface Topographic Assessment of Lung Volume and Pulmonary Function Tests in Idiopathic Scoliosis: A Preliminary Study. J Pediatr Orthop 2024; 44:366-372. [PMID: 38595095 DOI: 10.1097/bpo.0000000000002677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
OBJECTIVE Severe spinal deformity results in restrictive pulmonary disease from thoracic distortions and lung-volume limitations. Though spirometry and body plethysmography are widely accepted tests for pulmonary function tests (PFTs), they are time-consuming and require patient compliance. This study investigates whether surface topographic [surface topography (ST)] measurements of body volume difference (BVD) and torso volume difference between maximum inhale and exhale correlate to values determined on PFTs. METHODS This study included patients with idiopathic scoliosis and thoracic/thoracolumbar curves ≥40 degrees. Patients received ST scans, clinical examinations, and EOS biplanar radiographs on the same day. PFTs were performed within 3 months of ST/radiographic analysis. Univariate linear regression analysis was used to examine relationships between BVD, PFT values, and mean curves. RESULTS Sixteen patients (14.6 ± 2.2 y, 69% females) with idiopathic scoliosis and mean thoracic/thoracolumbar curves of 62 degrees ± 15˚ degrees (45 degrees to 93 degrees) were assessed. BVD displayed statistically high-positive positive correlations with forced vital capacity ( R = 0.863, P < 0.0001), forced expiratory volume in 1 second ( R = 0.870, P < 0.001), vital capacity ( R = 0.802, P < 0.0001), and TLC ( R = 0.831, P < 0.0001. Torso volume difference showed similarly high positive correlations to forced vital capacity, forced expiratory volume in 1 second, vital capacity, and TLC, but not residual volume. No correlations emerged between the mean thoracic/thoracolumbar curve and BVD or PFT values. CONCLUSION This study strongly endorses further investigation into ST scanning as an alternative to traditional PFTs for assessing pulmonary volumes. The noncontact and noninvasive nature of ST scanning presents a valuable alternative method for analyzing thoracic volume, particularly beneficial for patients unable to cooperate with standard PFTs. LEVEL OF EVIDENCE Level II-prognostic.
Collapse
|
3
|
Bulas DI, Fraser JL, Cilli K. Using MRI derived observed to expected total lung volume to predict lethality in fetal skeletal dysplasia. Pediatr Radiol 2024; 54:854-856. [PMID: 38438708 DOI: 10.1007/s00247-024-05893-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 02/16/2024] [Accepted: 02/19/2024] [Indexed: 03/06/2024]
|
4
|
Sanchez Giralt JA, Tusman G, Wallin M, Hallback M, Perez Lucendo A, Sanchez Galindo M, Abad Santamaria B, Paz Calzada E, Garcia Garcia P, Rodriguez Huerta D, Canabal Berlanga A, Suarez-Sipmann F. Clinical validation of a capnodynamic method for measuring end-expiratory lung volume in critically ill patients. Crit Care 2024; 28:142. [PMID: 38689313 PMCID: PMC11059761 DOI: 10.1186/s13054-024-04928-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 04/21/2024] [Indexed: 05/02/2024] Open
Abstract
RATIONALE End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION clinicaltrials.gov (NCT04045262).
Collapse
|
5
|
Otake S, Shiraishi Y, Chubachi S, Tanabe N, Maetani T, Asakura T, Namkoong H, Shimada T, Azekawa S, Nakagawara K, Tanaka H, Fukushima T, Watase M, Terai H, Sasaki M, Ueda S, Kato Y, Harada N, Suzuki S, Yoshida S, Tateno H, Yamada Y, Jinzaki M, Hirai T, Okada Y, Koike R, Ishii M, Hasegawa N, Kimura A, Imoto S, Miyano S, Ogawa S, Kanai T, Fukunaga K. Lung volume measurement using chest CT in COVID-19 patients: a cohort study in Japan. BMJ Open Respir Res 2024; 11:e002234. [PMID: 38663888 PMCID: PMC11043761 DOI: 10.1136/bmjresp-2023-002234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
OBJECTIVE This study aimed to investigate the utility of CT quantification of lung volume for predicting critical outcomes in COVID-19 patients. METHODS This retrospective cohort study included 1200 hospitalised patients with COVID-19 from 4 hospitals. Lung fields were extracted using artificial intelligence-based segmentation, and the percentage of the predicted (%pred) total lung volume (TLC (%pred)) was calculated. The incidence of critical outcomes and posthospitalisation complications was compared between patients with low and high CT lung volumes classified based on the median percentage of predicted TLCct (n=600 for each). Prognostic factors for residual lung volume loss were investigated in 208 patients with COVID-19 via a follow-up CT after 3 months. RESULTS The incidence of critical outcomes was higher in the low TLCct (%pred) group than in the high TLCct (%pred) group (14.2% vs 3.3%, p<0.0001). Multivariable analysis of previously reported factors (age, sex, body mass index and comorbidities) demonstrated that CT-derived lung volume was significantly associated with critical outcomes. The low TLCct (%pred) group exhibited a higher incidence of bacterial infection, heart failure, thromboembolism, liver dysfunction and renal dysfunction than the high TLCct (%pred) group. TLCct (%pred) at 3 months was similarly divided into two groups at the median (71.8%). Among patients with follow-up CT scans, lung volumes showed a recovery trend from the time of admission to 3 months but remained lower in critical cases at 3 months. CONCLUSION Lower CT lung volume was associated with critical outcomes, posthospitalisation complications and slower improvement of clinical conditions in COVID-19 patients.
Collapse
|
6
|
Mraz T, Asgari S, Karimi A, Breyer MK, Hartl S, Sunanta O, Ofenheimer A, Burghuber OC, Zacharasiewicz A, Lamprecht B, Schiffers C, Wouters EFM, Breyer-Kohansal R. Updated reference values for static lung volumes from a healthy population in Austria. Respir Res 2024; 25:155. [PMID: 38570835 PMCID: PMC10988832 DOI: 10.1186/s12931-024-02782-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 03/21/2024] [Indexed: 04/05/2024] Open
Abstract
BACKGROUND Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).
Collapse
|
7
|
Gatti S, Rezoagli E, Madotto F, Foti G, Bellani G. A non-invasive continuous and real-time volumetric monitoring in spontaneous breathing subjects based on bioimpedance-ExSpiron®Xi: a validation study in healthy volunteers. J Clin Monit Comput 2024; 38:539-551. [PMID: 38238635 PMCID: PMC10994998 DOI: 10.1007/s10877-023-01107-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 11/10/2023] [Indexed: 04/06/2024]
Abstract
Tidal volume (TV) monitoring breath-by-breath is not available at bedside in non-intubated patients. However, TV monitoring may be useful to evaluate the work of breathing. A non-invasive device based on bioimpedance provides continuous and real-time volumetric tidal estimation during spontaneous breathing. We performed a prospective study in healthy volunteers aimed at evaluating the accuracy, the precision and the trending ability of measurements of ExSpiron®Xi as compared with the gold standard (i.e. spirometry). Further, we explored whether the differences between the 2 devices would be improved by the calibration of ExSpiron®Xi with a pre-determined tidal volume. Analysis accounted for the repeated nature of measurements within each subject. We enrolled 13 healthy volunteers, including 5 men and 8 women. Tidal volume, TV/ideal body weight (IBW) and respiratory rate (RR) measured with spirometer (TVSpirometer) and with ExSpiron®Xi (TVExSpiron) showed a robust correlation, while minute ventilation (MV) showed a weak correlation, in both non/calibrated and calibrated steps. The analysis of the agreement showed that non-calibrated TVExSpiron underestimated TVspirometer, while in the calibrated steps, TVExSpiron overestimated TVspirometer. The calibration procedure did not reduce the average absolute difference (error) between TVSpirometer and TVExSpiron. This happened similarly for TV/IBW and MV, while RR showed high accuracy and precision. The trending ability was excellent for TV, TV/IBW and RR. The concordance rate (CR) was >95% in both calibrated and non-calibrated measurements. The trending ability of minute ventilation was limited. Absolute error for both calibrated and not calibrated values of TV, TV/IBW and MV accounting for repeated measurements was variably associated with BMI, height and smoking status. Conclusions: Non-invasive TV, TV/IBW and RR estimation by ExSpiron®Xi was strongly correlated with tidal ventilation according to the gold standard spirometer technique. This data was not confirmed for MV. The calibration of the device did not improve its performance. Although the accuracy of ExSpiron®Xi was mild and the precision was limited for TV, TV/IBW and MV, the trending ability of the device was strong specifically for TV, TV/IBW and RR. This makes ExSpiron®Xi a non-invasive monitoring system that may detect real-time tidal volume ventilation changes and then suggest the need to better optimize the patient ventilatory support.
Collapse
|
8
|
Ding W, Gu Y, Wang H, Wu H, Zhang X, Zhang R, Wang H, Huang L, Lv J, Xia B, Zhong W, He Q, Hou L. Prenatal MRI assessment of mediastinal shift angle as a feasible and effective risk stratification tool in isolated right-sided congenital diaphragmatic hernia. Eur Radiol 2024; 34:1524-1533. [PMID: 37644150 DOI: 10.1007/s00330-023-10178-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 06/21/2023] [Accepted: 07/07/2023] [Indexed: 08/31/2023]
Abstract
OBJECTIVES To develop a mediastinal shift angle (MSA) measurement method applicable to right-sided congenital diaphragmatic hernia (RCDH) in fetal MRI and to validate the predictive value of MSA in RCDH. METHODS Twenty-seven fetuses with isolated RCDH and 53 controls were included in our study. MSA was measured on MRI axial image at the level of four-chamber view of the fetal heart. The angle between the sagittal midline landmark line and the left boundary landmark line touching tangentially the lateral wall of the left ventricle was used to quantify MSA for RCDH. Appropriate statistical analyses were performed to determine whether MSA can be regarded as a valid predictive tool for postnatal outcomes. Furthermore, predictive performance of MSA was compared with that of lung area to head circumference ratio (LHR), observed/expected LHR (O/E LHR), total fetal lung volume (TFLV), and observed/expected TFLV (O/E TFLV). RESULTS MSA was significantly higher in the RCDH group than in the control group. MSA, LHR, O/E LHR, TFLV, and O/E TFLV were all correlated with postnatal survival, pulmonary hypertension (PH), and extracorporeal membrane oxygenation (ECMO) therapy (p < 0.05). Value of the AUC demonstrated good predictive performance of MSA for postnatal survival (0.901, 95%CI: (0.781-1.000)), PH (0.828, 95%CI: (0.661-0.994)), and ECMO therapy (0.813, 95%CI: (0.645-0.980)), which was similar to O/E TFLV but slightly better than TFLV, O/E LHR, and LHR. CONCLUSIONS We developed a measurement method of MSA for RCDH for the first time and demonstrated that MSA could be used to predict postnatal survival, PH, and ECMO therapy in RCDH. CLINICAL RELEVANCE STATEMENT Newly developed MRI assessment method of fetal MSA in RCDH offers a simple and effective risk stratification tool for patients with RCDH. KEY POINTS • We developed a measurement method of mediastinal shift angle for right-sided congenital diaphragmatic hernia for the first time and demonstrated its feasibility and reproducibility. • Mediastinal shift angle can predict more prognostic information other than survival in right-sided congenital diaphragmatic hernia with good performance. • Mediastinal shift angle can be used as a simple and effective risk stratification tool in right-sided congenital diaphragmatic hernia to improve planning of postnatal management.
Collapse
|
9
|
Veneroni C, Dellacà RL, Küng E, Bonomi B, Berger A, Werther T. Oscillometry for personalizing continuous distending pressure maneuvers: an observational study in extremely preterm infants. Respir Res 2024; 25:4. [PMID: 38178216 PMCID: PMC10765834 DOI: 10.1186/s12931-023-02639-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 12/15/2023] [Indexed: 01/06/2024] Open
Abstract
RATIONALE Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.
Collapse
|
10
|
Fernández Ceballos I, Ems J, Steinberg E, Nuñez Silveira JM, Hornos MB, Berdiñas Anfuso M, Videla C, Ciarrocchi NM, Carboni Bisso I, Las Heras M. Pulmonary strain and end-expiratory lung volume during apnea test: a comparative analysis using electrical impedance tomography. Medicina (B Aires) 2024; 84:359-363. [PMID: 38683525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2024] Open
Abstract
The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.
Collapse
|
11
|
Roach DJ, Szugye NA, Moore RA, Hossain MM, Morales DLS, Hayes D, Towe CT, Zafar F, Woods JC. Improved donor lung size matching by estimation of lung volumes based on chest X-ray measurements. Pediatr Transplant 2023; 27:e14594. [PMID: 37655840 DOI: 10.1111/petr.14594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 08/04/2023] [Accepted: 08/09/2023] [Indexed: 09/02/2023]
Abstract
RATIONALE Organ size matching is an important determinant of successful allocation and outcomes in lung transplantation. While computed tomography (CT) is the gold standard, it is rarely used in an organ-donor context, and chest X-ray (CXR) may offer a practical and accurate solution in estimating lung volumes for donor and recipient size matching. We compared CXR lung measurements to CT-measured lung volumes and traditional estimates of lung volume in the same subjects. METHODS Our retrospective study analyzed clinically obtained CXR and CT lung images of 250 subjects without evidence of lung disease (mean age 9.9 ± 7.8 years; 129 M/121F). From CT, each lung was semi-automatically segmented and total lung volumes were quantified. From anterior-posterior CXR view, each lung was manually segmented and areas were measured. Lung lengths from the apices to the mid-basal regions of each lung were measured from CXR. Quantified CT lung volumes were compared to the corresponding CXR lung lengths, CXR lung areas, height, weight, and predicted total lung capacity (pTLC). RESULTS There are strong and significant correlations between CT volumes and CXR lung areas in the right lung (R2 = .89, p < .0001), left lung (R2 = .87, p < .0001), and combined lungs (R2 = .89, p < .0001). Similar correlations were seen between CT volumes and CXR measured lung lengths in the right lung (R2 = .79, p < .0001) and left lung (R2 = .81, p < .0001). This correlation between anatomical lung volume (CT) and CXR was stronger than lung-volume correlation to height (R2 = .66, p < .0001), weight (R2 = .43, p < .0001), or pTLC (R2 = .66, p < .0001). CONCLUSION CXR measures correlate much more strongly with true lung volumes than height, weight, or pTLC. The ability to obtain efficient and more accurate lung volume via CXR has the potential to change our current listing practices of using height as a surrogate for lung size, with a case example provided.
Collapse
|
12
|
Wilson L, Whitby EH. MRI prediction of fetal lung volumes and the impact on counselling. Clin Radiol 2023; 78:955-959. [PMID: 37813756 DOI: 10.1016/j.crad.2023.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 08/25/2023] [Accepted: 09/04/2023] [Indexed: 10/11/2023]
Abstract
AIM To assess whether lung volume percentages in congenital diaphragmatic hernia (CDH) differ depending on which formula is used to calculate the expected volume for gestation and any potential impact this may have on perinatal counselling. MATERIALS AND METHODS Forty-seven patients with left-sided CDH who had undergone fetal magnetic resonance imaging (MRI) at Sheffield Teaching Hospitals were reviewed. The lung volumes were measured on MRI and compared with the volumes that would be expected at the given gestation for each patient. Expected values were calculated using four formulae from the literature and the authors' in-house method. These measurements were used to calculate the percentage total lung volume observed compared with the expected lung volume in a healthy fetus of the same gestation. The differences in percentage lung volumes using these five methods were then compared with how they relate to predicted rates of survival. How predicted survival would change depending on which formula was used to calculate the percentage lung volume was investigated with a view to how this may change the counselling given to a family. RESULTS In 10/47 (21%) patients, there was no change in the predicted percentage chance of survival depending on which formula was used to calculate the predicted lung volume. In 37/47 (79%), the predicted chance of survival changed depending on which formula was used to calculate the expected lung volume at the given gestation. In 20 (47%) of these cases, the change in predicted survival depending on which formula used was 45% (i.e., from 25% to 70% survival in four and from 50% to 95% survival in 16) and in two cases (4%) this difference was 70% (i.e., from 25% predicted survival to 95% predicted survival). CONCLUSION There are several different methods for calculating expected lung volumes for any given gestation. When used to estimate the percentage lung volume in patients with CDH, there is a large difference in values depending on which method is used. This in turn leads to a large variation in predicted survival with some patients in this study having either a 25% or 95% chance of survival depending on which method is used. This has a huge impact on perinatal counselling and the difficult decisions made by families.
Collapse
|
13
|
FitzMaurice TS, McCann C, Nazareth D, Hawkes S, Shaw M, McNamara PS, Walshaw M. Feasibility of dynamic chest radiography to calculate lung volumes in adult people with cystic fibrosis: a pilot study. BMJ Open Respir Res 2023; 10:e001309. [PMID: 37147023 PMCID: PMC10163553 DOI: 10.1136/bmjresp-2022-001309] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 04/21/2023] [Indexed: 05/07/2023] Open
Abstract
INTRODUCTION Dynamic chest radiography (DCR) is a novel, low-dose, real-time digital imaging system where software identifies moving thoracic structures and can automatically calculate lung areas. In an observational, prospective, non-controlled, single-centre pilot study, we compared it with whole-body plethysmography (WBP) in the measurement of lung volume subdivisions in people with cystic fibrosis (pwCF). METHODS Lung volume subdivisions were estimated by DCR using projected lung area (PLA) during deep inspiration, tidal breathing and full expiration, and compared with same-day WBP in 20 adult pwCF attending routine review. Linear regression models to predict lung volumes from PLA were developed. RESULTS Total lung area (PLA at maximum inspiration) correlated with total lung capacity (TLC) (r=0.78, p<0.001), functional residual lung area with functional residual capacity (FRC) (r=0.91, p<0.001), residual lung area with residual volume (RV) (r=0.82, p=0.001) and inspiratory lung area with inspiratory capacity (r=0.72, p=0.001). Despite the small sample size, accurate models were developed for predicting TLC, RV and FRC. CONCLUSION DCR is a promising new technology that can be used to estimate lung volume subdivisions. Plausible correlations between plethysmographic lung volumes and DCR lung areas were identified. Further studies are needed to build on this exploratory work in both pwCF and individuals without CF. TRIAL REGISTRATION NUMBER ISRCTN64994816.
Collapse
|
14
|
Vazquez Guillamet R, Rjob A, Bierhals A, Tague L, Marklin G, Halverson L, Witt C, Byers D, Hachem R, Gierada D, Brody SL, Takahashi T, Nava R, Kreisel D, Puri V, Trulock EP. Potential Role of Computed Tomography Volumetry in Size Matching in Lung Transplantation. Transplant Proc 2023; 55:432-439. [PMID: 36914438 PMCID: PMC10225152 DOI: 10.1016/j.transproceed.2023.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 02/02/2023] [Accepted: 02/03/2023] [Indexed: 03/14/2023]
Abstract
BACKGROUND Accumulated knowledge on the outcomes related to size mismatch in lung transplantation derives from predicted total lung capacity equations rather than individualized measurements of donors and recipients. The increasing availability of computed tomography (CT) makes it possible to measure the lung volumes of donors and recipients before transplantation. We hypothesize that CT-derived lung volumes predict a need for surgical graft reduction and primary graft dysfunction. METHODS Donors from the local organ procurement organization and recipients from our hospital from 2012 to 2018 were included if their CT exams were available. The CT lung volumes and plethysmography total lung capacity were measured and compared with predicted total lung capacity using Bland Altman methods. We used logistic regression to predict the need for surgical graft reduction and ordinal logistic regression to stratify the risk for primary graft dysfunction. RESULTS A total of 315 transplant candidates with 575 CT scans and 379 donors with 379 CT scans were included. The CT lung volumes closely approximated plethysmography lung volumes and differed from the predicted total lung capacity in transplant candidates. In donors, CT lung volumes systematically underestimated predicted total lung capacity. Ninety-four donors and recipients were matched and transplanted locally. Larger donor and smaller recipient lung volumes estimated by CT predicted a need for surgical graft reduction and were associated with higher primary graft dysfunction grade. CONCLUSION The CT lung volumes predicted the need for surgical graft reduction and primary graft dysfunction grade. Adding CT-derived lung volumes to the donor-recipient matching process may improve recipients' outcomes.
Collapse
|
15
|
Avena-Zampieri CL, Hutter J, Rutherford M, Milan A, Hall M, Egloff A, Lloyd DFA, Nanda S, Greenough A, Story L. Assessment of the fetal lungs in utero. Am J Obstet Gynecol MFM 2022; 4:100693. [PMID: 35858660 PMCID: PMC9811184 DOI: 10.1016/j.ajogmf.2022.100693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 07/12/2022] [Accepted: 07/12/2022] [Indexed: 01/07/2023]
Abstract
Antenatal diagnosis of abnormal pulmonary development has improved significantly over recent years because of progress in imaging techniques. Two-dimensional ultrasound is the mainstay of investigation of pulmonary pathology during pregnancy, providing good prognostication in conditions such as congenital diaphragmatic hernia; however, it is less validated in other high-risk groups such as those with congenital pulmonary airway malformation or preterm premature rupture of membranes. Three-dimensional assessment of lung volume and size is now possible using ultrasound or magnetic resonance imaging; however, the use of these techniques is still limited because of unpredictable fetal motion, and such tools have also been inadequately validated in high-risk populations other than those with congenital diaphragmatic hernia. The advent of advanced, functional magnetic resonance imaging techniques such as diffusion and T2* imaging, and the development of postprocessing pipelines that facilitate motion correction, have enabled not only more accurate evaluation of pulmonary size, but also assessment of tissue microstructure and perfusion. In the future, fetal magnetic resonance imaging may have an increasing role in the prognostication of pulmonary abnormalities and in monitoring current and future antenatal therapies to enhance lung development. This review aims to examine the current imaging methods available for assessment of antenatal lung development and to outline possible future directions.
Collapse
|
16
|
Shafiq M, Polhemus E, Perkins R, Forth V, Marshall MB. Bilateral Bronchoscopic Lung Volume Reduction After Surgical Fissure Completion. Chest 2022; 162:e73-e75. [PMID: 35940665 DOI: 10.1016/j.chest.2022.02.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 01/28/2022] [Accepted: 02/07/2022] [Indexed: 11/17/2022] Open
Abstract
Although bilateral lung volume reduction surgery has been shown to be safe and effective in carefully selected patients with upper lobe-predominant emphysema and hyperinflation, bronchoscopic lung volume reduction via placement of endobronchial valves is conventionally performed only unilaterally. Furthermore, it is not offered to patients with interlobar collateral ventilation because of the lack of clinical efficacy. We describe two novel management approaches including (1) bilateral bronchoscopic lung volume reduction, and (2) a combined thoracic surgical and interventional pulmonary procedure involving surgical fissure completion followed by endobronchial valve placement, which culminated in safe and effective lung volume reduction of both lungs along with an excellent patient outcome.
Collapse
|
17
|
Su Y, Qiu ZS, Chen J, Ju MJ, Ma GG, He JW, Yu SJ, Liu K, Lure FYM, Tu GW, Zhang YY, Luo Z. Usage of compromised lung volume in monitoring steroid therapy on severe COVID-19. Respir Res 2022; 23:105. [PMID: 35488261 PMCID: PMC9051749 DOI: 10.1186/s12931-022-02025-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 04/14/2022] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Quantitative computed tomography (QCT) analysis may serve as a tool for assessing the severity of coronavirus disease 2019 (COVID-19) and for monitoring its progress. The present study aimed to assess the association between steroid therapy and quantitative CT parameters in a longitudinal cohort with COVID-19. METHODS Between February 7 and February 17, 2020, 72 patients with severe COVID-19 were retrospectively enrolled. All 300 chest CT scans from these patients were collected and classified into five stages according to the interval between hospital admission and follow-up CT scans: Stage 1 (at admission); Stage 2 (3-7 days); Stage 3 (8-14 days); Stage 4 (15-21 days); and Stage 5 (22-31 days). QCT was performed using a threshold-based quantitative analysis to segment the lung according to different Hounsfield unit (HU) intervals. The primary outcomes were changes in percentage of compromised lung volume (%CL, - 500 to 100 HU) at different stages. Multivariate Generalized Estimating Equations were performed after adjusting for potential confounders. RESULTS Of 72 patients, 31 patients (43.1%) received steroid therapy. Steroid therapy was associated with a decrease in %CL (- 3.27% [95% CI, - 5.86 to - 0.68, P = 0.01]) after adjusting for duration and baseline %CL. Associations between steroid therapy and changes in %CL varied between different stages or baseline %CL (all interactions, P < 0.01). Steroid therapy was associated with decrease in %CL after stage 3 (all P < 0.05), but not at stage 2. Similarly, steroid therapy was associated with a more significant decrease in %CL in the high CL group (P < 0.05), but not in the low CL group. CONCLUSIONS Steroid administration was independently associated with a decrease in %CL, with interaction by duration or disease severity in a longitudinal cohort. The quantitative CT parameters, particularly compromised lung volume, may provide a useful tool to monitor COVID-19 progression during the treatment process. Trial registration Clinicaltrials.gov, NCT04953247. Registered July 7, 2021, https://clinicaltrials.gov/ct2/show/NCT04953247.
Collapse
|
18
|
Mingote Á, Albajar A, García Benedito P, Garcia-Suarez J, Pelosi P, Ball L, García-Fernández J. Prevalence and clinical consequences of atelectasis in SARS-CoV-2 pneumonia: a computed tomography retrospective cohort study. BMC Pulm Med 2021; 21:267. [PMID: 34404383 PMCID: PMC8369136 DOI: 10.1186/s12890-021-01638-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 08/11/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The aim of the study is to estimate the prevalence of atelectasis assessed with computer tomography (CT) in SARS-CoV-2 pneumonia and the relationship between the amount of atelectasis with oxygenation impairment, Intensive Care Unit admission rate and the length of in-hospital stay. PATIENTS AND METHODS Two-hundred thirty-seven patients admitted to the hospital with SARS-CoV-2 pneumonia diagnosed by clinical, radiology and molecular tests in the nasopharyngeal swab who underwent a chest computed tomography because of a respiratory worsening from Apr 1 to Apr 30, 2020 were included in the study. Patients were divided into three groups depending on the presence and amount of atelectasis at the computed tomography: no atelectasis, small atelectasis (< 5% of the estimated lung volume) or large atelectasis (> 5% of the estimated lung volume). In all patients, clinical severity, oxygen-therapy need, Intensive Care Unit admission rate, the length of in-hospital stay and in-hospital mortality data were collected. RESULTS Thirty patients (19%) showed small atelectasis while eight patients (5%) showed large atelectasis. One hundred and seventeen patients (76%) did not show atelectasis. Patients with large atelectasis compared to patients with small atelectasis had lower SatO2/FiO2 (182 vs 411 respectively, p = 0.01), needed more days of oxygen therapy (20 vs 5 days respectively, p = 0,02), more frequently Intensive Care Unit admission (75% vs 7% respectively, p < 0.01) and a longer period of hospitalization (40 vs 14 days respectively p < 0.01). CONCLUSION In patients with SARS-CoV-2 pneumonia, atelectasis might appear in up to 24% of patients and the presence of larger amount of atelectasis is associated with worse oxygenation and clinical outcome.
Collapse
|
19
|
Messineo L, Perger E, Corda L, Joosten SA, Fanfulla F, Pedroni L, Terrill PI, Lombardi C, Wellman A, Hamilton GS, Malhotra A, Vailati G, Parati G, Sands SA. Breath-holding as a novel approach to risk stratification in COVID-19. Crit Care 2021; 25:208. [PMID: 34127052 PMCID: PMC8200551 DOI: 10.1186/s13054-021-03630-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 06/06/2021] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Despite considerable progress, it remains unclear why some patients admitted for COVID-19 develop adverse outcomes while others recover spontaneously. Clues may lie with the predisposition to hypoxemia or unexpected absence of dyspnea ('silent hypoxemia') in some patients who later develop respiratory failure. Using a recently-validated breath-holding technique, we sought to test the hypothesis that gas exchange and ventilatory control deficits observed at admission are associated with subsequent adverse COVID-19 outcomes (composite primary outcome: non-invasive ventilatory support, intensive care admission, or death). METHODS Patients with COVID-19 (N = 50) performed breath-holds to obtain measurements reflecting the predisposition to oxygen desaturation (mean desaturation after 20-s) and reduced chemosensitivity to hypoxic-hypercapnia (including maximal breath-hold duration). Associations with the primary composite outcome were modeled adjusting for baseline oxygen saturation, obesity, sex, age, and prior cardiovascular disease. Healthy controls (N = 23) provided a normative comparison. RESULTS The adverse composite outcome (observed in N = 11/50) was associated with breath-holding measures at admission (likelihood ratio test, p = 0.020); specifically, greater mean desaturation (12-fold greater odds of adverse composite outcome with 4% compared with 2% desaturation, p = 0.002) and greater maximal breath-holding duration (2.7-fold greater odds per 10-s increase, p = 0.036). COVID-19 patients who did not develop the adverse composite outcome had similar mean desaturation to healthy controls. CONCLUSIONS Breath-holding offers a novel method to identify patients with high risk of respiratory failure in COVID-19. Greater breath-hold induced desaturation (gas exchange deficit) and greater breath-holding tolerance (ventilatory control deficit) may be independent harbingers of progression to severe disease.
Collapse
|
20
|
Alves AFF, Miranda JRA, Reis F, Oliveira AA, Souza SAS, Fortaleza CMCB, Tanni SE, Castro JTS, Pina DR. Automatic algorithm for quantifying lung involvement in patients with chronic obstructive pulmonary disease, infection with SARS-CoV-2, paracoccidioidomycosis and no lung disease patients. PLoS One 2021; 16:e0251783. [PMID: 34111131 PMCID: PMC8191897 DOI: 10.1371/journal.pone.0251783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 05/03/2021] [Indexed: 11/19/2022] Open
Abstract
In this work, we aimed to develop an automatic algorithm for the quantification of total volume and lung impairments in four different diseases. The quantification was completely automatic based upon high resolution computed tomography exams. The algorithm was capable of measuring volume and differentiating pulmonary involvement including inflammatory process and fibrosis, emphysema, and ground-glass opacities. The algorithm classifies the percentage of each pulmonary involvement when compared to the entire lung volume. Our algorithm was applied to four different patients groups: no lung disease patients, patients diagnosed with SARS-CoV-2, patients with chronic obstructive pulmonary disease, and patients with paracoccidioidomycosis. The quantification results were compared with a semi-automatic algorithm previously validated. Results confirmed that the automatic approach has a good agreement with the semi-automatic. Bland-Altman (B&A) demonstrated a low dispersion when comparing total lung volume, and also when comparing each lung impairment individually. Linear regression adjustment achieved an R value of 0.81 when comparing total lung volume between both methods. Our approach provides a reliable quantification process for physicians, thus impairments measurements contributes to support prognostic decisions in important lung diseases including the infection of SARS-CoV-2.
Collapse
|
21
|
Berger KI, Adam O, Dal Negro RW, Kaminsky DA, Shiner RJ, Burgos F, de Jongh FHC, Cohen I, Fredberg JJ. Validation of a Novel Compact System for the Measurement of Lung Volumes. Chest 2021; 159:2356-2365. [PMID: 33539839 PMCID: PMC8411450 DOI: 10.1016/j.chest.2021.01.052] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/04/2021] [Accepted: 01/09/2021] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Current techniques for measuring absolute lung volumes rely on bulky and expensive equipment and are complicated to use for the operator and the patient. A novel method for measurement of absolute lung volumes, the MiniBox method, is presented. RESEARCH QUESTION Across a population of patients and healthy participants, do values for total lung capacity (TLC) determined by the novel compact device (MiniBox, PulmOne Advanced Medical Devices, Ltd.) compare favorably with measurements determined by traditional whole body plethysmography? STUDY DESIGN AND METHODS A total of 266 participants (130 men) and respiratory patients were recruited from five global centers (three in Europe and two in the United States). The study population comprised individuals with obstructive (n = 197) and restrictive (n = 33) disorders as well as healthy participants (n = 36). TLC measured by conventional plethysmography (TLCPleth) was compared with TLC measured by the MiniBox (TLCMB). RESULTS TLC values ranged between 2.7 and 10.9 L. The normalized root mean square difference (NSD) between TLCPleth and TLCMB was 7.0% in healthy participants. In obstructed patients, the NSD was 7.9% in mild obstruction and 9.1% in severe obstruction. In restricted patients, the NSD was 7.8% in mild restriction and 13.9% in moderate and severe restriction. No significant differences were found between TLC values obtained by the two measurement techniques. Also no significant differences were found in results obtained among the five centers. INTERPRETATION TLC as measured by the novel MiniBox system is not significantly different from TLC measured by conventional whole body plethysmography, thus validating the MiniBox method as a reliable method to measure absolute lung volumes.
Collapse
|
22
|
Khan A, Markus A, Rittmann T, Albers J, Alves F, Hülsmann S, Dullin C. Simple low dose radiography allows precise lung volume assessment in mice. Sci Rep 2021; 11:4163. [PMID: 33602964 PMCID: PMC7893164 DOI: 10.1038/s41598-021-83319-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 01/08/2021] [Indexed: 02/07/2023] Open
Abstract
X-ray based lung function (XLF) as a planar method uses dramatically less X-ray dose than computed tomography (CT) but so far lacked the ability to relate its parameters to pulmonary air volume. The purpose of this study was to calibrate the functional constituents of XLF that are biomedically decipherable and directly comparable to that of micro-CT and whole-body plethysmography (WBP). Here, we developed a unique set-up for simultaneous assessment of lung function and volume using XLF, micro-CT and WBP on healthy mice. Our results reveal a strong correlation of lung volumes obtained from radiographic XLF and micro-CT and demonstrate that XLF is superior to WBP in sensitivity and precision to assess lung volumes. Importantly, XLF measurement uses only a fraction of the radiation dose and acquisition time required for CT. Therefore, the redefined XLF approach is a promising tool for preclinical longitudinal studies with a substantial potential of clinical translation.
Collapse
|
23
|
Pippard BJ, Neal MA, Maunder AM, Hollingsworth KG, Biancardi A, Lawson RA, Fisher H, Matthews JNS, Simpson AJ, Wild JM, Thelwall PE. Reproducibility of 19 F-MR ventilation imaging in healthy volunteers. Magn Reson Med 2021; 85:3343-3352. [PMID: 33507591 PMCID: PMC7986730 DOI: 10.1002/mrm.28660] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 12/07/2020] [Accepted: 12/07/2020] [Indexed: 01/23/2023]
Abstract
Purpose To assess the reproducibility of percentage ventilated lung volume (%VV) measurements in healthy volunteers acquired by fluorine (19F)‐MRI of inhaled perfluoropropane, implemented at two research sites. Methods In this prospective, ethically approved study, 40 healthy participants were recruited (May 2018‐June 2019) to one of two research sites. Participants underwent a single MRI scan session on a 3T scanner, involving periodic inhalation of a 79% perfluoropropane/21% oxygen gas mixture. Each gas inhalation session lasted about 30 seconds, consisting of three deep breaths of gas followed by a breath‐hold. Four 19F‐MR ventilation images were acquired per participant, each separated by approximately 6 minutes. The value of %VV was determined by registering separately acquired 1H images to ventilation images before semi‐automated image segmentation, performed independently by two observers. Reproducibility of %VV measurements was assessed by components of variance, intraclass correlation coefficients, coefficients of variation (CoV), and the Dice similarity coefficient. Results The MRI scans were well tolerated throughout, with no adverse events. There was a high degree of consistency in %VV measurements for each participant (CoVobserver1 = 0.43%; CoVobserver2 = 0.63%), with overall precision of %VV measurements determined to be within ± 1.7% (95% confidence interval). Interobserver agreement in %VV measurements revealed a high mean Dice similarity coefficient (SD) of 0.97 (0.02), with only minor discrepancies between observers. Conclusion We demonstrate good reproducibility of %VV measurements in a group of healthy participants using 19F‐MRI of inhaled perfluoropropane. Our methods have been successfully implemented across two different study sites, supporting the feasibility of performing larger multicenter clinical studies.
Collapse
|
24
|
Strozza D, Wilhite DP, Babb TG, Bhammar DM. Pitfalls in Expiratory Flow Limitation Assessment at Peak Exercise in Children: Role of Thoracic Gas Compression. Med Sci Sports Exerc 2020; 52:2310-2319. [PMID: 33064406 PMCID: PMC7573195 DOI: 10.1249/mss.0000000000002378] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PURPOSE Thoracic gas compression and exercise-induced bronchodilation can influence the assessment of expiratory flow limitation (EFL) during cardiopulmonary exercise tests. The purpose of this study was to examine the effect of thoracic gas compression and exercise-induced bronchodilation on the assessment of EFL in children with and without obesity. METHODS Forty children (10.7 ± 1.0 yr; 27 obese; 15 with EFL) completed pulmonary function tests and incremental exercise tests. Inspiratory capacity maneuvers were performed during the incremental exercise test for the placement of tidal flow volume loops within the maximal expiratory flow volume (MEFV) loops, and EFL was calculated as the overlap between the tidal and the MEFV loops. MEFV loops were plotted with volume measured at the lung using plethysmography (MEFVp), with volume measured at the mouth using spirometry concurrent with measurements in the plethysmograph (MEFVm), and from spirometry before (MEFVpre) and after (MEFVpost) the incremental exercise test. Only the MEFVp loops were corrected for thoracic gas compression. RESULTS Not correcting for thoracic gas compression resulted in incorrect diagnosis of EFL in 23% of children at peak exercise. EFL was 26% ± 15% VT higher for MEFVm compared with MEFVp (P < 0.001), with no differences between children with and without obesity (P = 0.833). The difference in EFL estimation using MEFVpre (37% ± 30% VT) and MEFVpost (31% ± 26% VT) did not reach statistical significance (P = 0.346). CONCLUSIONS Not correcting the MEFV loops for thoracic gas compression leads to the overdiagnosis and overestimation of EFL. Because most commercially available metabolic measurement systems do not correct for thoracic gas compression during spirometry, there may be a significant overdiagnosis of EFL in cardiopulmonary exercise testing. Therefore, clinicians must exercise caution while interpreting EFL when the MEFV loop is derived through spirometry.
Collapse
|
25
|
Verleden SE, Kirby M, Everaerts S, Vanstapel A, McDonough JE, Verbeken EK, Braubach P, Boone MN, Aslam D, Verschakelen J, Ceulemans LJ, Neyrinck AP, Van Raemdonck DE, Vos R, Decramer M, Hackett TL, Hogg JC, Janssens W, Verleden GM, Vanaudenaerde BM. Small airway loss in the physiologically ageing lung: a cross-sectional study in unused donor lungs. THE LANCET RESPIRATORY MEDICINE 2020; 9:167-174. [PMID: 33031747 DOI: 10.1016/s2213-2600(20)30324-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 07/01/2020] [Accepted: 07/01/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Physiological lung ageing is associated with a gradual decline in dynamic lung volumes and a progressive increase in residual volume due to diminished elastic recoil of the lung, loss of alveolar tissue, and lower chest wall compliance. However, the effects of ageing on the small airways (ie, airways <2·0 mm in diameter) remain largely unknown. By using a combination of ex-vivo conventional CT (resolution 1 mm), whole lung micro-CT (resolution 150 μm), and micro-CT of extracted cores (resolution 10 μm), we aimed to provide a multiresolution assessment of the small airways in lung ageing in a large cohort of never smokers. METHODS For this cross-sectional study, we included donor lungs collected from 32 deceased never-smoking donors (age range 16-83 years). Ex-vivo CT and whole lung high-resolution CT (micro-CT) were used to determine total airway numbers, stratified by airway diameter. Micro-CT was used to assess the number, length, and diameter of terminal bronchioles (ie, the last generation of conducting airways); mean linear intercept; and surface density in four lung tissue cores from each lung, extracted using a uniform sampling approach. Regression β coefficients are calculated using linear regression and polynomial models. FINDINGS Ex-vivo CT analysis showed an age-dependent decrease in the number of airways of diameter 2·0 mm to less than 2·5 mm (β coefficient per decade -0·119, 95% CI -0·193 to -0·045; R2=0·29) and especially in airways smaller than 2·0 mm in diameter (-0·158, -0·233 to -0·084; R2=0·47), between 30 and 80 years of age, but not of the larger (≥2·5 mm) diameter airways (-0·00781, -0·04409 to 0·02848; R2=0·0007). In micro-CT analysis of small airways, the total number of terminal bronchioles per lung increased until the age of 30 years, after which an almost linear decline in the number of terminal bronchioles was observed (β coefficient per decade -2035, 95% CI -2818 to -1252; R2=0·55), accompanied by a non-significant increase in alveolar airspace size (6·44, -0·57 to 13·45, R2=0·10). Moreover, this decrease in terminal bronchioles was associated with the age-related decline of pulmonary function predicted by healthy reference values. INTERPRETATION Loss of terminal bronchioles is an important structural component of age-related decline in pulmonary function of healthy, non-smoking individuals. FUNDING Research Foundation-Flanders, KU Leuven, Parker B Francis Foundation, UGent, Canadian Institutes for Health.
Collapse
|