26
|
Woo JP, Dong ML, Kong F, McElhinney DB, Schiavone N, Chan F, Lui GK, Haddad F, Bernstein D, Marsden A. Improved Right Ventricular Energy Efficiency by 4-Dimensional Flow Magnetic Resonance Imaging After Harmony Valve Implantation. JACC. ADVANCES 2023; 2:100284. [PMID: 37691969 PMCID: PMC10487049 DOI: 10.1016/j.jacadv.2023.100284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/12/2023]
|
27
|
Wise-Faberowski L, Long J, Ma M, Nadel HR, Shek J, Feinstein JA, Martin E, Hanley FL, McElhinney DB. Serial Lung Perfusion Scintigraphy After Unifocalization and Repair of Tetralogy of Fallot With Major Aortopulmonary Collaterals. World J Pediatr Congenit Heart Surg 2023; 14:261-272. [PMID: 36972512 DOI: 10.1177/21501351231162959] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Background In patients with tetralogy of Fallot and major aortopulmonary collaterals (MAPCAs), pulmonary blood supply is highly variable. Our approach to this condition emphasizes complete unifocalization of the pulmonary circulation, incorporating all lung segments and addressing stenoses out to the segmental level. Post-repair, we recommend serial lung perfusion scintigraphy (LPS) to assess short-term changes in pulmonary blood flow distribution. Methods We reviewed post-discharge and follow-up LPS performed through three years post-repair and analyzed serial changes in perfusion, risk factors for change, and the relationship between LPS parameters and pulmonary artery reintervention. Results Of 543 patients who had postoperative LPS results in our system, 317 (58%) had only a predischarge LPS available for review, while 226 had 1 (20%) or more (22%) follow-up scans within three years. Overall, pulmonary flow distribution prior to discharge was balanced, and there was minimal change over time; however, there was considerable patient-to-patient variation in both metrics. On multivariable mixed modeling, time after repair ( P = .025), initial anatomy consisting of a ductus arteriosus to one lung ( P < .001), and age at repair ( P = .014) were associated with changes on serial LPS. Patients who had follow-up LPS were more likely to undergo pulmonary artery reintervention, but within that cohort, LPS parameters were not associated with reintervention risk. Conclusion Serial LPS during the first year after MAPCAs repair is a noninvasive method of screening for significant post-repair pulmonary artery stenosis that occurs in a small but important minority of patients. In patients who received follow-up LPS beyond the perioperative period, there was minimal change over time in the population overall, but large changes in some patients and considerable variability. There was no statistical association between LPS findings and pulmonary artery reintervention.
Collapse
|
28
|
Kight A, Pirozzi I, Liang X, McElhinney DB, Han AK, Dual SA, Cutkosky M. Decoupling Transmission and Transduction for Improved Durability of Highly Stretchable, Soft Strain Sensing: Applications in Human Health Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:1955. [PMID: 36850551 PMCID: PMC9967534 DOI: 10.3390/s23041955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/24/2023] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.
Collapse
|
29
|
Edwards LA, Feng F, Iqbal M, Fu Y, Sanyahumbi A, Hao S, McElhinney DB, Ling XB, Sable C, Luo J. Machine Learning for Pediatric Echocardiographic Mitral Regurgitation Detection. J Am Soc Echocardiogr 2023; 36:96-104.e4. [PMID: 36191670 DOI: 10.1016/j.echo.2022.09.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Revised: 09/23/2022] [Accepted: 09/24/2022] [Indexed: 01/10/2023]
Abstract
BACKGROUND Echocardiography-based screening for valvular disease in at-risk asymptomatic children can result in early diagnosis. These screening programs, however, are resource intensive and may not be feasible in many resource-limited settings. Automated echocardiographic diagnosis may enable more widespread echocardiographic screening, early diagnosis, and improved outcomes. In this feasibility study, the authors sought to build a machine learning model capable of identifying mitral regurgitation (MR) on echocardiography. METHODS Echocardiograms were labeled by clip for view and by frame for the presence of MR. The labeled data were used to build two convolutional neural networks to perform the stepwise tasks of classifying the clips (1) by view and (2) by the presence of any MR, including physiologic, in parasternal long-axis color Doppler views. The view classification model was developed using 66,330 frames, and model performance was evaluated using a hold-out testing data set with 45 echocardiograms (11,730 frames). The MR detection model was developed using 938 frames, and model performance was evaluated using a hold-out testing data set with 42 echocardiograms (182 frames). Metrics to evaluate model performance included accuracy, precision, recall, F1 score (average of precision and recall, ranging from 0 to 1, with 1 suggesting perfect precision and recall), and receiver operating characteristic analysis. RESULTS For the parasternal long-axis view with color Doppler, the view classification convolutional neural network achieved an F1 score of 0.97. The MR detection convolutional neural network achieved testing accuracy of 0.86 and an area under the receiver operating characteristic curve of 0.91. CONCLUSIONS A machine learning model is capable of discerning MR on transthoracic echocardiography. This is an encouraging step toward machine learning-based diagnosis of valvular heart disease on pediatric echocardiography.
Collapse
|
30
|
Baddour LM, Weimer MB, Wurcel AG, McElhinney DB, Marks LR, Fanucchi LC, Esquer Garrigos Z, Pettersson GB, DeSimone DC. Management of Infective Endocarditis in People Who Inject Drugs: A Scientific Statement From the American Heart Association. Circulation 2022; 146:e187-e201. [PMID: 36043414 DOI: 10.1161/cir.0000000000001090] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
BACKGROUND The American Heart Association has sponsored both guidelines and scientific statements that address the diagnosis, management, and prevention of infective endocarditis. As a result of the unprecedented and increasing incidence of infective endocarditis cases among people who inject drugs, the American Heart Association sponsored this original scientific statement. It provides a more in-depth focus on the management of infective endocarditis among this unique population than what has been provided in prior American Heart Association infective endocarditis-related documents. METHODS A writing group was named and consisted of recognized experts in the fields of infectious diseases, cardiology, addiction medicine, and cardiovascular surgery in October 2021. A literature search was conducted in Embase on November 19, 2021, and multiple terms were used, with 1345 English-language articles identified after removal of duplicates. CONCLUSIONS Management of infective endocarditis in people who inject drugs is complex and requires a unique approach in all aspects of care. Clinicians must appreciate that it requires involvement of a variety of specialists and that consultation by addiction-trained clinicians is as important as that of more traditional members of the endocarditis team to improve infective endocarditis outcomes. Preventive measures are critical in people who inject drugs and are cured of an initial bout of infective endocarditis because they remain at extremely high risk for subsequent bouts of infective endocarditis, regardless of whether injection drug use is continued.
Collapse
|
31
|
Chubb H, Bulic A, Mah D, Moore JP, Janousek J, Fumanelli J, Asaki SY, Pflaumer A, Hill AC, Escudero C, Kwok SY, Mangat J, Ochoa Nunez LA, Balaji S, Rosenthal E, Regan W, Horndasch M, Asakai H, Tanel R, Czosek RJ, Young ML, Bradley DJ, Paul T, Fischbach P, Malloy-Walton L, McElhinney DB, Dubin AM. Impact and Modifiers of Ventricular Pacing in Patients With Single Ventricle Circulation. J Am Coll Cardiol 2022; 80:902-914. [PMID: 36007989 DOI: 10.1016/j.jacc.2022.05.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 05/04/2022] [Accepted: 05/23/2022] [Indexed: 10/15/2022]
Abstract
BACKGROUND Palliation of the single ventricle (SV) circulation is associated with a burden of lifelong complications. Previous studies have identified that the need for a permanent ventricular pacing system (PPMv) may be associated with additional adverse long-term outcomes. OBJECTIVES The goal of this study was to quantify the attributable risk of PPMv in patients with SV, and to identify modifiable risk factors. METHODS This international study was sponsored by the Pediatric and Congenital Electrophysiology Society. Centers contributed baseline and longitudinal data for functionally SV patients with PPMv. Enrollment was at implantation. Controls were matched 1:1 to PPMv subjects by ventricular morphology and sex, identified within center, and enrolled at matched age. Primary outcome was transplantation or death. RESULTS In total, 236 PPMv subjects and 213 matched controls were identified (22 centers, 9 countries). Median age at enrollment was 5.3 years (quartiles: 1.5-13.2 years), follow-up 6.9 years (3.4-11.6 years). Median percent ventricular pacing (Vp) was 90.8% (25th-75th percentile: 4.3%-100%) in the PPMv cohort. Across 213 matched pairs, multivariable HR for death/transplant associated with PPMv was 3.8 (95% CI 1.9-7.6; P < 0.001). Within the PPMv population, higher Vp (HR: 1.009 per %; P = 0.009), higher QRS z-score (HR: 1.19; P = 0.009) and nonapical lead position (HR: 2.17; P = 0.042) were all associated with death/transplantation. CONCLUSIONS PPMv in patients with SV is associated with increased risk of heart transplantation and death, despite controlling for increased associated morbidity of the PPMv cohort. Increased Vp, higher QRS z-score, and nonapical ventricular lead position are all associated with higher risk of adverse outcome and may be modifiable risk factors.
Collapse
|
32
|
Choi PS, Nasirov T, Hanley F, Peng L, McElhinney DB, Ma M. Innominate artery patency after direct cannulation in neonates. JTCVS Tech 2022; 14:171-176. [PMID: 35967223 PMCID: PMC9367197 DOI: 10.1016/j.xjtc.2022.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 02/14/2022] [Accepted: 05/17/2022] [Indexed: 11/29/2022] Open
Abstract
Objective Methods Results Conclusions
Collapse
|
33
|
Dual SA, Verdonk C, Amsallem M, Pham J, Obasohan C, Nataf P, McElhinney DB, Arunamata A, Kuznetsova T, Zamanian R, Feinstein JA, Marsden A, Haddad F. Elucidating tricuspid Doppler signal interpolation and its implication for assessing pulmonary hypertension. Pulm Circ 2022; 12:e12125. [PMID: 36016669 PMCID: PMC9395694 DOI: 10.1002/pul2.12125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 07/07/2022] [Accepted: 08/02/2022] [Indexed: 11/06/2022] Open
Abstract
Doppler echocardiography plays a central role in the assessment of pulmonary hypertension (PAH). We aim to improve quality assessment of systolic pulmonary arterial pressure (SPAP) by applying a cubic polynomial interpolation to digitized tricuspid regurgitation (TR) waveforms. Patients with PAH and advanced lung disease were divided into three cohorts: a derivation cohort (n = 44), a validation cohort (n = 71), an outlier cohort (n = 26), and a non-PAH cohort (n = 44). We digitized TR waveforms and analyzed normalized duration, skewness, kurtosis, and first and second derivatives of pressure. Cubic polynomial interpolation was applied to three physiology-driven phases: the isovolumic phase, ejection phase, and "shoulder" point phase. Coefficients of determination and a Bland-Altman analysis was used to assess bias between methods. The cubic polynomial interpolation of the TR waveform correlated strongly with expert read right ventricular systolic pressure (RVSP) with R 2 > 0.910 in the validation cohort. The biases when compared to invasive SPAP measured within 24 h were 6.03 [4.33; 7.73], -2.94 [1.47; 4.41], and -3.11 [-4.52; -1.71] mmHg, for isovolumic, ejection, and shoulder point interpolations, respectively. In the outlier cohort with more than 30% difference between echocardiographic estimates and invasive SPAP, cubic polynomial interpolation significantly reduced underestimation of RVSP. Cubic polynomial interpolation of the TR waveform based on isovolumic or early ejection phase may improve RVSP estimates.
Collapse
|
34
|
Purkey NJ, Ma C, Lee HC, Hintz SR, Shaw GM, McElhinney DB, Carmichael SL. Distance from home to birth hospital, transfer, and mortality in neonates with hypoplastic left heart syndrome in California. Birth Defects Res 2022; 114:662-673. [PMID: 35488460 DOI: 10.1002/bdr2.2020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Revised: 04/04/2022] [Accepted: 04/11/2022] [Indexed: 11/12/2022]
Abstract
BACKGROUND Prior studies report a lower risk of mortality among neonates with hypoplastic left heart syndrome (HLHS) who are born at a cardiac surgical center, but many neonates with HLHS are born elsewhere and transferred for repair. We investigated the associations between the distance from maternal home to birth hospital, the need for transfer after birth, sociodemographic factors, and mortality in infants with HLHS in California from 2006 to 2011. METHODS We used linked data from two statewide databases to identify neonates for this study. Three groups were included in the analysis: "lived close/not transferred," "lived close/transferred," and "lived far/not transferred." We defined "lived close" versus "lived far" as 11 miles, the median distance from maternal residence to birth hospital. Log-binomial regression models were used to identify the association between sociodemographic variables, distance to birth hospital and transfer. Cox proportional hazards models were used to identify the association between mortality and distance to birth hospital and transfer. Models were adjusted for sociodemographic variables. RESULTS Infants in the lived close/not transferred and the lived close/transferred groups (vs. the lived far/not transferred group) were more likely to live in census tracts above the 75th percentile for poverty with relative risks 1.94 (95% confidence interval [CI] 1.41-2.68) and 1.21 (95% CI 1.05-1.40), respectively. Neonatal mortality was higher among the lived close/not transferred group compared with the lived far/not transferred group (hazard ratio 1.77, 95% CI 1.17-2.67). CONCLUSIONS Infants born to mothers experiencing poverty were more likely to be born close to home. Infants with HLHS who were born close to home and not transferred to a cardiac center had a higher risk of neonatal mortality than infants who were delivered far from home and not transferred. Future studies should identify the barriers to delivery at a cardiac center for mothers experiencing poverty.
Collapse
|
35
|
Taylor A, Yang J, Dubin AM, Chubb MH, Motonaga K, Goodyer W, Giacone H, Peng LF, Romfh AW, McElhinney DB, Ceresnak SR. VENTRICULAR ARRHYTHMIAS FOLLOWING TRANSCATHETER PULMONARY VALVE REPLACEMENT WITH THE HARMONY(C) TPV 25 DEVICE. J Am Coll Cardiol 2022. [DOI: 10.1016/s0735-1097(22)02353-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
36
|
Ma M, Peng LF, Zhang Y, Wise-Faberowski L, Martin E, Hanley FL, McElhinney DB. Relation Between Pulmonary Artery Pressures Measured Intraoperatively and at One-Year Catheterization After Unifocalization and Repair of Tetralogy with Major Aortopulmonary Collateral Arteries. Semin Thorac Cardiovasc Surg 2022; 34:1013-1025. [PMID: 35092847 DOI: 10.1053/j.semtcvs.2022.01.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 01/20/2022] [Indexed: 11/11/2022]
Abstract
To assess the relationships between pulmonary artery (PA) pressure and the PA:aortic systolic pressure ratio measured intraoperatively and at surveillance catheterization in patients achieving complete unifocalization and repair for tetralogy of Fallot with major aortopulmonary collateral arteries (TOF/MAPCAs). This was a single-center retrospective cohort analysis of all patients who underwent complete repair of TOF/MAPCAs from 2002-2019 and received a postoperative surveillance catheterization at our center 6-24 months after surgery. Associations between intraoperative and catheter hemodynamic data were analyzed. 163 patients were included. Median systolic PA pressure was 30 (quartiles 26, 35) and 35 (28, 42) mmHg intraoperatively and at catherization respectively; systolic aortic pressure 90 (86, 100) and 84 (76, 92); and PA:aortic pressure ratio was 0.33 (0.28, 0.40) and 0.41 (0.34, 0.49). Moderate correlation was found between the intraoperative and catheter-based hemodynamics, with the majority of systolic PA pressures within 10mmHg and PA:Ao systolic ratios within 0.1. Changes in the ratio were influenced to a similar degree by differences in PA and aortic pressures. Surgical and/or catheter reinterventions were more common in patients with both higher intraoperative PA systolic pressure and PA:aortic systolic ratios and in those with greater discrepancy between intraoperative and catheterization values. PA systolic pressure and the PA:aortic systolic pressure ratio measured immediately after repair remain useful metrics for assessing the initial operative PA reconstruction, and as indicators of longer term hemodynamics. Initially elevated and subsequently discrepant PA systolic pressure and PA:aortic systolic pressure ratios were associated with higher rates of reintervention. (Figure 7).
Collapse
|
37
|
McElhinney DB, Zhang Y, Levi DS, Georgiev S, Biernacka EK, Goldstein BH, Shahanavaz S, Qureshi AM, Cabalka AK, Bauser-Heaton H, Torres AJ, Morray BH, Armstrong AK, Millan-Iturbe O, Peng LF, Aboulhosn JA, Rużyłło W, Berger F, Sondergaard L, Schranz D, Cheatham JP, Jones TK, Ewert P, Schubert S. Reintervention and Survival After Transcatheter Pulmonary Valve Replacement. J Am Coll Cardiol 2022; 79:18-32. [PMID: 34991785 DOI: 10.1016/j.jacc.2021.10.031] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 10/04/2021] [Accepted: 10/05/2021] [Indexed: 12/18/2022]
Abstract
BACKGROUND Transcatheter pulmonary valve (TPV) replacement (TPVR) has become the standard therapy for postoperative pulmonary outflow tract dysfunction in patients with a prosthetic conduit/valve, but there is limited information about risk factors for death or reintervention after this procedure. OBJECTIVES This study sought to evaluate mid- and long-term outcomes after TPVR in a large multicenter cohort. METHODS International registry focused on time-related outcomes after TPVR. RESULTS Investigators submitted data for 2,476 patients who underwent TPVR and were followed up for 8,475 patient-years. A total of 95 patients died after TPVR, most commonly from heart failure (n = 24). The cumulative incidence of death was 8.9% (95% CI: 6.9%-11.5%) 8 years after TPVR. On multivariable analysis, age at TPVR (HR: 1.04 per year; 95% CI: 1.03-1.06 per year; P < 0.001), a prosthetic valve in other positions (HR: 2.1; 95% CI: 1.2-3.7; P = 0.014), and an existing transvenous pacemaker/implantable cardioverter-defibrillator (HR: 2.1; 95% CI: 1.3-3.4; P = 0.004) were associated with death. A total of 258 patients underwent TPV reintervention. At 8 years, the cumulative incidence of any TPV reintervention was 25.1% (95% CI: 21.8%-28.5%) and of surgical TPV reintervention was 14.4% (95% CI: 11.9%-17.2%). Risk factors for surgical reintervention included age (0.95 per year [95% CI: 0.93-0.97 per year]; P < 0.001), prior endocarditis (2.5 [95% CI: 1.4-4.3]; P = 0.001), TPVR into a stented bioprosthetic valve (1.7 [95% CI: 1.2-2.5]; P = 0.007), and postimplant gradient (1.4 per 10 mm Hg [95% CI: 1.2-1.7 per 10 mm Hg]: P < 0.001). CONCLUSIONS These findings support the conclusion that survival and freedom from reintervention or surgery after TPVR are generally comparable to outcomes of surgical conduit/valve replacement across a wide age range.
Collapse
|
38
|
Jones TK, McElhinney DB, Vincent JA, Hellenbrand WE, Cheatham JP, Berman DP, Zahn EM, Khan DM, Rhodes JF, Weng S, Bergersen LJ. Long-Term Outcomes After Melody Transcatheter Pulmonary Valve Replacement in the US Investigational Device Exemption Trial. Circ Cardiovasc Interv 2021; 15:e010852. [PMID: 34930015 PMCID: PMC8765216 DOI: 10.1161/circinterventions.121.010852] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Supplemental Digital Content is available in the text. Background: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease. Methods: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020. The primary outcome was freedom from transcatheter pulmonary valve (TPV) dysfunction (freedom from reoperation, reintervention, moderate or severe pulmonary regurgitation, and/or mean RVOT gradient >40 mm Hg). Secondary end points included stent fracture, catheter reintervention, surgical conduit replacement, and death. Results: One hundred seventy-one subjects with RVOT conduit or bioprosthetic pulmonary valve dysfunction were enrolled. One hundred fifty underwent Melody TPV replacement. Median age was 19 years (Q1–Q3: 15–26). Median discharge mean RVOT Doppler gradient was 17 mm Hg (Q1–Q3: 12–22). The 149 patients implanted >24 hours were followed for a median of 8.4 years (Q1–Q3: 5.4–10.1). At 10 years, estimated freedom from mortality was 90%, from reoperation 79%, and from any reintervention 60%. Ten-year freedom from TPV dysfunction was 53% and was significantly shorter in children than in adults. Estimated freedom from TPV-related endocarditis was 81% at 10 years (95% CI, 69%–89%), with an annualized rate of 2.0% per patient-year. Conclusions: Ten-year outcomes from the Melody Investigational Device Exemption trial affirm the benefits of Melody TPV replacement in the lifetime management of patients with RVOT conduits and bioprosthetic pulmonary valves by providing sustained symptomatic and hemodynamic improvement in the majority of patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00740870.
Collapse
|
39
|
Duong SQ, Zheng L, Xia M, Jin B, Liu M, Li Z, Hao S, Alfreds ST, Sylvester KG, Widen E, Teuteberg JJ, McElhinney DB, Ling XB. Identification of patients at risk of new onset heart failure: Utilizing a large statewide health information exchange to train and validate a risk prediction model. PLoS One 2021; 16:e0260885. [PMID: 34890438 PMCID: PMC8664210 DOI: 10.1371/journal.pone.0260885] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 10/22/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND New-onset heart failure (HF) is associated with poor prognosis and high healthcare utilization. Early identification of patients at increased risk incident-HF may allow for focused allocation of preventative care resources. Health information exchange (HIE) data span the entire spectrum of clinical care, but there are no HIE-based clinical decision support tools for diagnosis of incident-HF. We applied machine-learning methods to model the one-year risk of incident-HF from the Maine statewide-HIE. METHODS AND RESULTS We included subjects aged ≥ 40 years without prior HF ICD9/10 codes during a three-year period from 2015 to 2018, and incident-HF defined as assignment of two outpatient or one inpatient code in a year. A tree-boosting algorithm was used to model the probability of incident-HF in year two from data collected in year one, and then validated in year three. 5,668 of 521,347 patients (1.09%) developed incident-HF in the validation cohort. In the validation cohort, the model c-statistic was 0.824 and at a clinically predetermined risk threshold, 10% of patients identified by the model developed incident-HF and 29% of all incident-HF cases in the state of Maine were identified. CONCLUSIONS Utilizing machine learning modeling techniques on passively collected clinical HIE data, we developed and validated an incident-HF prediction tool that performs on par with other models that require proactively collected clinical data. Our algorithm could be integrated into other HIEs to leverage the EMR resources to provide individuals, systems, and payors with a risk stratification tool to allow for targeted resource allocation to reduce incident-HF disease burden on individuals and health care systems.
Collapse
|
40
|
Huang Q, Hao S, You J, Yao X, Li Z, Schilling J, Thyparambil S, Liao WL, Zhou X, Mo L, Ladella S, Davies-Balch SR, Zhao H, Fan D, Whitin JC, Cohen HJ, McElhinney DB, Wong RJ, Shaw GM, Stevenson DK, Sylvester KG, Ling XB. Early-pregnancy prediction of risk for pre-eclampsia using maternal blood leptin/ceramide ratio: discovery and confirmation. BMJ Open 2021; 11:e050963. [PMID: 34824115 PMCID: PMC8627403 DOI: 10.1136/bmjopen-2021-050963] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVE This study aimed to develop a blood test for the prediction of pre-eclampsia (PE) early in gestation. We hypothesised that the longitudinal measurements of circulating adipokines and sphingolipids in maternal serum over the course of pregnancy could identify novel prognostic biomarkers that are predictive of impending event of PE early in gestation. STUDY DESIGN Retrospective discovery and longitudinal confirmation. SETTING Maternity units from two US hospitals. PARTICIPANTS Six previously published studies of placental tissue (78 PE and 95 non-PE) were compiled for genomic discovery, maternal sera from 15 women (7 non-PE and 8 PE) enrolled at ProMedDx were used for sphingolipidomic discovery, and maternal sera from 40 women (20 non-PE and 20 PE) enrolled at Stanford University were used for longitudinal observation. OUTCOME MEASURES Biomarker candidates from discovery were longitudinally confirmed and compared in parallel to the ratio of placental growth factor (PlGF) and soluble fms-like tyrosine kinase (sFlt-1) using the same cohort. The datasets were generated by enzyme-linked immunosorbent and liquid chromatography-tandem mass spectrometric assays. RESULTS Our discovery integrating genomic and sphingolipidomic analysis identified leptin (Lep) and ceramide (Cer) (d18:1/25:0) as novel biomarkers for early gestational assessment of PE. Our longitudinal observation revealed a marked elevation of Lep/Cer (d18:1/25:0) ratio in maternal serum at a median of 23 weeks' gestation among women with impending PE as compared with women with uncomplicated pregnancy. The Lep/Cer (d18:1/25:0) ratio significantly outperformed the established sFlt-1/PlGF ratio in predicting impending event of PE with superior sensitivity (85% vs 20%) and area under curve (0.92 vs 0.52) from 5 to 25 weeks of gestation. CONCLUSIONS Our study demonstrated the longitudinal measurement of maternal Lep/Cer (d18:1/25:0) ratio allows the non-invasive assessment of PE to identify pregnancy at high risk in early gestation, outperforming the established sFlt-1/PlGF ratio test.
Collapse
|
41
|
Adamson GT, Peng LF, Perry SB, Hanley FL, McElhinney DB. Comprehensive diagnostic catheterization in children with major aortopulmonary collateral arteries: A review of catheterization technique and anatomic nomenclature. Catheter Cardiovasc Interv 2021; 99:1129-1137. [PMID: 34800077 DOI: 10.1002/ccd.30013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 10/15/2021] [Accepted: 10/30/2021] [Indexed: 11/07/2022]
Abstract
Achieving an optimal surgical result in patients with major aortopulmonary collateral arteries (MAPCAs) requires a thorough preoperative evaluation of the anatomy and physiology of the pulmonary circulation. This review provides a detailed description of diagnostic catheterization in patients with MAPCAs, including a summary of catheterization techniques, an overview of commonly used terms, and a review of MAPCA and pulmonary artery angiographic anatomy.
Collapse
|
42
|
Maskatia SA, Kwiatkowski D, Bhombal S, Davis AS, McElhinney DB, Tacy TA, Algaze C, Blumenfeld Y, Quirin A, Punn R. A Fetal Risk Stratification Pathway for Neonatal Aortic Coarctation Reduces Medical Exposure. J Pediatr 2021; 237:102-108.e3. [PMID: 34181988 DOI: 10.1016/j.jpeds.2021.06.047] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 06/16/2021] [Accepted: 06/21/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To test the hypothesis that a fetal stratification pathway will effectively discriminate between infants at different levels of risk for surgical coarctation and reduce unnecessary medicalization. STUDY DESIGN We performed a pre-post nonrandomized study in which we prospectively assigned fetuses with prenatal concern for coarctation to 1 of 3 risk categories and implemented a clinical pathway for postnatal management. Postnatal clinical outcomes were compared with those in a historical control group that were not triaged based on the pathway. RESULTS The study cohort comprised 109 fetuses, including 57 treated along the fetal coarctation pathway and 52 historical controls. Among mild-risk fetuses, 3% underwent surgical coarctation repair (0% of those without additional heart defects), compared with 27% of moderate-risk and 63% of high-risk fetuses. The combined fetal aortic, mitral, and isthmus z-score best discriminated which infants underwent surgery (area under the curve = 0.78; 95% CI, 0.66-0.91). Compared with historical controls, infants triaged according to the fetal coarctation pathway had fewer delivery location changes (76% vs 55%; P = .025) and less umbilical venous catheter placement (74% vs 51%; P = .046). Trends toward shorter intensive care unit stay, hospital stay, and time to enteral feeding did not reach statistical significance. CONCLUSIONS A stratified risk-assignment pathway effectively identifies a group of fetuses with a low rate of surgical coarctation and reduces unnecessary medicalization in infants who do not undergo aortic surgery. Incorporation of novel measurements or imaging techniques may improve the specificity of high-risk criteria.
Collapse
|
43
|
Vaikunth SS, Haeffele C, McElhinney DB, Lui GK, Romfh AW. Erratum to “The atrial switch patient with a dilated subpulmonic left ventricle” [Int. J. Cardiol. Congenit. Heart Dis. 4 (August 2021) 100153]. INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2021. [DOI: 10.1016/j.ijcchd.2021.100223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
44
|
McElhinney DB, Zhang Y, Aboulhosn JA, Morray BH, Biernacka EK, Qureshi AM, Torres AJ, Shahanavaz S, Goldstein BH, Cabalka AK, Bauser-Heaton H, Georgiev S, Berger F, Millan-Iturbe O, Peng LF, Armstrong AK, Levi DS, Fronczak-Jakubczyk A, Sondergaard L, Anderson JH, Schranz D, Jones TK, Cheatham JP, Schubert S, Ewert P. Multicenter Study of Endocarditis After Transcatheter Pulmonary Valve Replacement. J Am Coll Cardiol 2021; 78:575-589. [PMID: 34353535 DOI: 10.1016/j.jacc.2021.05.044] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 04/02/2021] [Accepted: 05/18/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND Endocarditis has emerged as one of the most impactful adverse events after transcatheter pulmonary valve replacement (TPVR), but there is limited information about risk factors for and outcomes of this complication. OBJECTIVES The purpose of this study was to evaluate risk factors for and outcomes of endocarditis in a large multicenter cohort. METHODS The authors established an international registry focused on characterizing endocarditis after TPVR, including the incidence, risk factors, characteristics, and outcomes. RESULTS Investigators submitted data for 2,476 patients who underwent TPVR between July 2005 and March 2020 and were followed for 8,475 patient-years. In total, 182 patients were diagnosed with endocarditis a median of 2.7 years after TPVR, for a cumulative incidence of 9.5% (95% CI: 7.9%-11.1%) at 5 years and 16.9% (95% CI: 14.2%-19.8%) at 8 years (accounting for competing risks: death, heart transplant, and explant) and an annualized incidence of 2.2 per 100 patient-years. Staphylococcus aureus and Viridans group Streptococcus species together accounted for 56% of cases. Multivariable analysis confirmed that younger age, a previous history of endocarditis, and a higher residual gradient were risk factors for endocarditis, but transcatheter pulmonary valve type was not. Overall, right ventricular outflow tract (RVOT) reintervention was less often to treat endocarditis than for other reasons, but valve explant was more often caused by endocarditis. Endocarditis was severe in 44% of patients, and 12 patients (6.6%) died, nearly all of whom were infected with Staphylococcus aureus. CONCLUSIONS The incidence of endocarditis in this multicenter registry was constant over time and consistent with prior smaller studies. The findings of this study, along with ongoing efforts to understand and mitigate risk, will be critical to improve the lifetime management of patients with heart disease involving the RVOT. Although endocarditis can be a serious adverse outcome, TPVR remains an important tool in the management of RVOT dysfunction.
Collapse
|
45
|
Dykes JC, Rosenthal DN, Bernstein D, McElhinney DB, Chrisant MRK, Daly KP, Ameduri RK, Knecht K, Richmond ME, Lin KY, Urschel S, Simmonds J, Simpson KE, Albers EL, Khan A, Schumacher K, Almond CS, Chen S. Clinical and hemodynamic characteristics of the pediatric failing Fontan. J Heart Lung Transplant 2021; 40:1529-1539. [PMID: 34412962 DOI: 10.1016/j.healun.2021.07.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 07/02/2021] [Accepted: 07/20/2021] [Indexed: 10/20/2022] Open
Abstract
AIM To describe the clinical and hemodynamic characteristics of Fontan failure in children listed for heart transplant. METHODS In a nested study of the Pediatric Heart Transplant Society, 16 centers contributed information on Fontan patients listed for heart transplant between 2005and 2013. Patients were classified into four mutually exclusive phenotypes: Fontan with abnormal lymphatics (FAL), Fontan with reduced systolic function (FRF), Fontan with preserved systolic function (FPF), and Fontan with "normal" hearts (FNH). Primary outcome was waitlist and post-transplant mortality. RESULTS 177 children listed for transplant were followed over a median 13 (IQR 4-31) months, 84 (47%) were FAL, 57 (32%) FRF, 22 (12%) FNH, and 14 (8%) FPF. Hemodynamic characteristics differed between the 4 groups: Fontan pressure (FP) was most elevated with FPF (median 22, IQR 18-23, mmHg) and lowest with FAL (16, 14-20, mmHg); cardiac index (CI) was lowest with FRF (2.8, 2.3-3.4, L/min/m2). In the entire cohort, 66% had FP >15 mmHg, 21% had FP >20 mmHg, and 10% had CI <2.2 L/min/m2. FRF had the highest risk of waitlist mortality (21%) and FNH had the highest risk of post-transplant mortality (36%). CONCLUSIONS Elevated Fontan pressure is more common than low cardiac output in pediatric failing Fontan patients listed for transplant. Subtle hemodynamic differences exist between the various phenotypes of pediatric Fontan failure. Waitlist and post-transplant mortality risks differ by phenotype.
Collapse
|
46
|
Abstract
Introduction: Advancements in surgery and management have resulted in a growing population of aging adults with tetralogy of Fallot (TOF). As a result, there has been a parallel growth in late complications associated with the sequelae from the underlying cardiac anomalies as well as the surgical and other interventional treatments.Areas covered: Here, we review challenges related to an aging population of patients with TOF, particularly late complications, and highlight advances in management and key areas for future research. Pulmonary regurgitation, heart failure, arrhythmias, and aortic complications are some of these late complications. There is also a growing incidence of acquired cardiovascular disease, obesity, and diabetes associated with aging. Management of these late complications and acquired comorbidities continues to evolve as research provides insights into long-term outcomes from medical therapies and surgical interventions.Expert opinion: The management of an aging TOF population will continue to transform with advances in imaging technologies to identify subclinical disease and valve replacement technologies that will prevent and mitigate disease progression. In the coming years, we speculate that there will be more data to support the use of novel heart failure therapies in TOF and consensus guidelines on the management of refractory arrhythmias and aortic complications.
Collapse
|
47
|
Dual SA, Maforo NG, McElhinney DB, Prosper A, Wu HH, Maskatia S, Renella P, Halnon N, Ennis DB. Right Ventricular Function and T1-Mapping in Boys With Duchenne Muscular Dystrophy. J Magn Reson Imaging 2021; 54:1503-1513. [PMID: 34037289 DOI: 10.1002/jmri.27729] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/04/2021] [Accepted: 05/05/2021] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Clinical management of boys with Duchenne muscular dystrophy (DMD) relies on in-depth understanding of cardiac involvement, but right ventricular (RV) structural and functional remodeling remains understudied. PURPOSE To evaluate several analysis methods and identify the most reliable one to measure RV pre- and postcontrast T1 (RV-T1) and to characterize myocardial remodeling in the RV of boys with DMD. STUDY TYPE Prospective. POPULATION Boys with DMD (N = 27) and age-/sex-matched healthy controls (N = 17) from two sites. FIELD STRENGTH/SEQUENCE 3.0 T using balanced steady state free precession, motion-corrected phase sensitive inversion recovery and modified Look-Locker inversion recovery sequences. ASSESSMENT Biventricular mass (Mi), end-diastolic volume (EDVi) and ejection fraction (EF) assessment, tricuspid annular excursion (TAE), late gadolinium enhancement (LGE), pre- and postcontrast myocardial T1 maps. The RV-T1 reliability was assessed by three observers in four different RV regions of interest (ROI) using intraclass correlation (ICC). STATISTICAL TESTS The Wilcoxon rank sum test was used to compare RV-T1 differences between DMD boys with negative LGE(-) or positive LGE(+) and healthy controls. Additionally, correlation of precontrast RV-T1 with functional measures was performed. A P-value <0.05 was considered statistically significant. RESULTS A 1-pixel thick RV circumferential ROI proved most reliable (ICC > 0.91) for assessing RV-T1. Precontrast RV-T1 was significantly higher in boys with DMD compared to controls. Both LGE(-) and LGE(+) boys had significantly elevated precontrast RV-T1 compared to controls (1543 [1489-1597] msec and 1550 [1402-1699] msec vs. 1436 [1399-1473] msec, respectively). Compared to healthy controls, boys with DMD had preserved RVEF (51.8 [9.9]% vs. 54.2 [7.2]%, P = 0.31) and significantly reduced RVMi (29.8 [9.7] g vs. 48.0 [15.7] g), RVEDVi (69.8 [29.7] mL/m2 vs. 89.1 [21.9] mL/m2 ), and TAE (22.0 [3.2] cm vs. 26.0 [4.7] cm). Significant correlations were found between precontrast RV-T1 and RVEF (β = -0.48%/msec) and between LV-T1 and LVEF (β = -0.51%/msec). DATA CONCLUSION Precontrast RV-T1 is elevated in boys with DMD compared to healthy controls and is negatively correlated with RVEF. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 2.
Collapse
|
48
|
Maeda K, Lui GK, Zhang Y, Maskatia SA, Romfh A, Yarlagadda VV, Hanley FL, McElhinney DB. Durability of Pulmonary Valve Replacement with Large Diameter Stented Porcine Bioprostheses. Semin Thorac Cardiovasc Surg 2021; 34:994-1000. [PMID: 33971298 DOI: 10.1053/j.semtcvs.2021.03.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 03/11/2021] [Indexed: 11/11/2022]
Abstract
There is limited information about durability of large diameter porcine bioprostheses implanted for pulmonary valve replacement (PVR). We studied patients who underwent surgical PVR from 2002-2019 with a stented porcine bioprosthetic valve (BPV) with a labeled size ≥27 mm. The primary outcome was freedom from reintervention. During the study period, 203 patients underwent PVR using a porcine BPV ≥27 mm, 94% of whom received a Mosaic valve (Medtronic Inc., Minneapolis, MN). Twenty patients underwent reintervention from 3.4-12.0 years after PVR: 5 surgical and 15 transcatheter PVR procedures. The indication for reintervention was regurgitation in 13 patients, stenosis in 2, mixed disease in 4, and endocarditis in 1. Estimated freedom from reintervention was 97±1% at 5 years and 82±4% at 10 years, and freedom from prosthesis dysfunction (moderate or severe regurgitation and/or a maximum Doppler gradient ≥50 mm Hg) over time was 91±2% at 5 years and 74±4% at 10 years. Younger age and smaller true valve diameter were associated with shorter freedom from reintervention, but valve oversizing was not. The durability of large stented porcine bioprostheses in the pulmonary position is generally excellent, particularly in adolescents and adults, similar to various other types of BPV. In the current study, relative valve size was not associated with valve longevity, although the low event-rate in this population was a limiting factor.
Collapse
|
49
|
Long ZB, Adamson GT, Peng LF, Perry SB, Wise-Faberowski L, Hanley FL, McElhinney DB. Balloon Angioplasty for Pulmonary Artery Stenosis After Complete Unifocalization and Repair of Tetralogy of Fallot With Major Aortopulmonary Collaterals. THE JOURNAL OF INVASIVE CARDIOLOGY 2021; 33:E378-E386. [PMID: 33908895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
OBJECTIVES The objective of this study was to assess procedural outcomes of balloon pulmonary artery (PA) angioplasty procedures after complete repair of tetralogy of Fallot with major aortopulmonary collateral arteries (TOF/MAPCAs). BACKGROUND Our approach to patients with TOF/MAPCAs emphasizes early complete unifocalization and repair. Major PA reinterventions are relatively uncommon. Balloon PA angioplasty is often used, but the effectiveness of balloon PA angioplasty in this population is unknown. METHODS The study cohort comprised patients who underwent complete unifocalization and repair of TOF/ MAPCAs at our center between 2002-2018 and underwent balloon PA angioplasty after repair. To assess immediate procedural outcomes, pre- and postintervention PA measurements were compared. RESULTS We reviewed 134 vessels that were dilated a median of 1.1 years after repair in 60 patients (median 2 PA branches per patient). Treated vessels included 15 central, 64 lobar, and 55 segmental branches. The median PA diameter at the level of stenosis increased from 1.9 mm to 3.3 mm (P<.001), and the median diameter increase was 50%. All but 6 treated vessels were enlarged. The stenosis-distal diameter ratio increased from a median of 64% to 89% (P<.001). The median central PA to aortic systolic pressure ratio was 47% before and 39% after intervention (P<.001). CONCLUSIONS Balloon PA angioplasty was acutely effective at treating most stenoses of reconstructed PA branches after repair of TOF/MAPCAs. Simple angioplasty can be a useful tool in treating isolated or modest stenoses after unifocalization/PA reconstruction surgery using our approach.
Collapse
|
50
|
Kreutzer J, Armstrong AK, Rome JJ, Zellers TM, Balzer DT, Zampi JD, Cabalka AK, Javois AJ, Turner DR, Gray RG, Moore JW, Weng S, Jones TK, Khan DM, Vincent JA, Hellenbrand WE, Cheatham JP, Bergersen LJ, McElhinney DB. Comparison of the investigational device exemption and post-approval trials of the Melody transcatheter pulmonary valve. Catheter Cardiovasc Interv 2021; 98:E262-E274. [PMID: 33780150 DOI: 10.1002/ccd.29657] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 11/03/2020] [Accepted: 03/14/2021] [Indexed: 11/09/2022]
Abstract
OBJECTIVE We compared 5-year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post-approval study (PAS) and the investigational device exemption (IDE) trial. BACKGROUND As a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a "real-world" environment. The 5-year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared. METHODS The cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time-related outcomes and valve-related adverse events were compared between the two trials with Kaplan-Meier curves and log-rank testing. RESULTS 167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both. CONCLUSIONS Hemodynamic and time-related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real-world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post-approval studies as part of the regulatory process for Class III medical devices.
Collapse
|