Cavalier E, Fraser CG, Bhattoa HP, Heijboer AC, Makris K, Ulmer CZ, Vesper HW, Vasikaran S, Lukas P, Delanaye P, Carobene A. Analytical Performance Specifications for 25-Hydroxyvitamin D Examinations. Nutrients 2021; 13:431. [PMID: 33525653 PMCID: PMC7911223 DOI: 10.3390/nu13020431] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 01/25/2021] [Accepted: 01/25/2021] [Indexed: 12/21/2022] Open
Abstract
Currently the 25-hydroxy vitamin D (25(OH)D) concentration is thought to be the best estimate of the vitamin D status of an individual. Unfortunately, its measurement remains complex, despite recent technological advances. We evaluated the biological variation (BV) of 25(OH)D in order to set analytical performance specifications (APS) for measurement uncertainty (MU). Six European laboratories recruited 91 healthy participants. The 25(OH)D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate on a Lumipulse G1200 (Fujirebio, Tokyo, Japan). The linear regression of the mean 25(OH)D concentrations at each blood collection showed that participants were not in a steady state. The dissection of the 10-sample collection into two subsets, namely collections 1-5 and 6-10, did not allow for correction of the lack of homogeneity: estimates of the within-subject BV ranged from 5.8% to 7.1% and the between-subject BV ranged from 25.0% to 39.2%. Methods that would differentiate a difference induced by 25(OH)D supplementation at p < 0.05 should have MU < 13.6%, while at p < 0.01, the MU should be <9.6%. The development of APS using BV assumes a steady state of patients. The findings in this study suggest that patients are not in steady state. Therefore, APS that are based on MU appear to be more appropriate.
Collapse
|
27
|
Ulmer CZ, Smith B, Thonkulpitak J, Hardin J, Danilenko U, Frame T, Cheng PY, Vesper HW. Development of a Sensitive High-Resolution Mass Spectrometry Approach for Urea Nitrogen Quantitation in Small Volumes of Bronchoalveolar Lavage Fluid (BALF). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2270-2276. [PMID: 32931276 DOI: 10.1021/jasms.0c00231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A sensitive, selective, and quantitative method incorporating high-resolution mass spectrometry was developed for the determination of blood urea nitrogen (BUN) in bronchoalveolar lavage fluid. The method requires no sample cleanup or derivatization prior to analysis. High-performance liquid chromatography (HPLC) on a Hypersil Gold PFP column (100 × 3 mm, 3 μm particle size) connected to a C18 guard column was employed for a 10 min chromatographic separation. The detection of urea was achieved using a Thermo Scientific Q-Exactive Plus instrument incorporating selected ion monitoring (SIM) modes for the protonated adduct of urea. The urea analytical measuring range for the method is 0.047-17.134 mg/dL, resulting in a BUN analytical measurement range of 0.022-8.007 mg/dL, which allows for quantitation over 3 orders of magnitude (R2 = 0.999). In addition, the method is suitable for small sample volumes (15 μL) with a high level of accuracy, precision, and specificity.
Collapse
|
28
|
Ulmer CZ, Koelmel JP, Jones CM, Garrett TJ, Aristizabal-Henao JJ, Vesper HW, Bowden JA. A Review of Efforts to Improve Lipid Stability during Sample Preparation and Standardization Efforts to Ensure Accuracy in the Reporting of Lipid Measurements. Lipids 2020; 56:3-16. [PMID: 32519378 DOI: 10.1002/lipd.12263] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 05/03/2020] [Accepted: 05/19/2020] [Indexed: 11/07/2022]
Abstract
Lipidomics is a rapidly growing field, fueled by developments in analytical instrumentation and bioinformatics. To date, most researchers and industries have employed their own lipidomics workflows without a consensus on best practices. Without a community-wide consensus on best practices for the prevention of lipid degradation and transformations through sample collection and analysis, it is difficult to assess the quality of lipidomics data and hence trust results. Clinical studies often rely on samples being stored for weeks or months until they are analyzed, but inappropriate sampling techniques, storage temperatures, and analytical protocols can result in the degradation of complex lipids and the generation of oxidized or hydrolyzed metabolite artifacts. While best practices for lipid stability are sample dependent, it is generally recommended that strategies during sample preparation capable of quenching enzymatic activity and preventing oxidation should be considered. In addition, after sample preparation, lipid extracts should be stored in organic solvents with antioxidants at -20 °C or lower in an airtight container without exposure to light or oxygen. This will reduce or eliminate sublimation, and chemically and physically induced molecular transformations such as oxidation, enzymatic transformation, and photon/heat-induced degradation. This review explores the available literature on lipid stability, with a particular focus on human health and/or clinical lipidomic applications. Specifically, this includes a description of known mechanisms of lipid degradation, strategies, and considerations for lipid storage, as well as current efforts for standardization and quality insurance of protocols.
Collapse
|
29
|
Sugahara O, Danilenko U, Poynter K, Collins L, Khoshnam N, Coffman C, Ribera A, Laughlin B, Dahya K, Bianca S, Arndt A, Ulmer CZ, Fidelia P, Wirtz D, Vesper HW, Zhou H. SAT-733 Improving the Diagnosis, Treatment, and Prevention of Endocrine Diseases Through Accurate and Reliable Laboratory Measurements with CDC’s Clinical Standardization Programs. J Endocr Soc 2020. [PMCID: PMC7207912 DOI: 10.1210/jendso/bvaa046.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Laboratory measurements are critical for the correct diagnosis and treatment of patients as well as in the investigation of chronic diseases such as hypogonadism, PCOS, and bone-and kidney-related diseases. Inaccurate measurements can lead to misclassification of patients and incorrect treatment. Furthermore, the effective use of research findings in patient care is prevented. The CDC Clinical Standardization Programs (CDC CSP) assess the analytical performance of assays against performance goals defined by clinical and medical organizations. The CDC CSP assist with assay calibration, the certification of analytical performance, and the monitoring of analytical performance during the measurement of patient and/or study samples. CDC CSP have programs in place for the calibration and certification of commercial assays and laboratory developed tests (LDTs) for total testosterone (TT), estradiol (E2), vitamin D (VD), free thyroxine (FT4), total cholesterol (TC), total glycerides (TG), HDL-cholesterol (HDL-C), and LDL-cholesterol (LDL-C). The programs available for monitoring analytical performance during routine testing include TT, VD, TC, TG, HDL-C, apolipoprotein AI and B. CDC CSP also support accuracy-based external quality assurance surveys such as those offered by the College of American Pathologists. Enrollment of assays and LDTs in CDC’s certification programs has resulted in improvements in calibration accuracy; i.e. the absolute mean bias of assays participating in the CDC Vitamin D Standardization Certification Program was well below the allowable bias of 5% each year. Assays standardized in CDC’s certification programs also demonstrated higher accuracy in routine patient testing; i.e. CDC VD certified assays have a lower bias compared to non-certified assays. Similar observations were made with assays certified in the CDC’s program for TT. Monitoring data over the past 10 years from the CDC Lipid Standardization Program indicated that the majority of TC measurements performed in routine testing were consistently within the recommended bias limits of ±3%. CDC CSP continue to improve the analytical performance of assays by addressing measurement bias caused by factors other than incorrect calibration such as interfering compounds. The programs are responding to new clinical and public health needs with the addition of new analytes such as PTH and glucose. The CDC CSP support projects aiming at establishing reference intervals and other research studies. The CDC CSP work with stakeholders, such as the Partnership for the Accurate Testing of Hormones and the Endocrine Society, to educate the clinical and laboratory communities about the importance of using standardized assays in patient care, research, and public health. References: Partnership for Accurate Hormone Testing (PATH). www.hormoneassays.org. College of American Pathologists (CAP). www.cap.org.
Collapse
|
30
|
Han J, Heinemann L, Ginsberg BH, Alva S, Appel M, Bess S, Chen KY, Freckmann G, Harris DR, Hartwig M, Hinzmann R, Kerr D, Krouwer J, Morrow L, Nichols J, Pfützner A, Pleus S, Rice M, Sacks DB, Schlueter K, Vesper HW, Klonoff DC. The YSI 2300 Analyzer Replacement Meeting Report. J Diabetes Sci Technol 2020; 14:679-686. [PMID: 32174135 PMCID: PMC7576944 DOI: 10.1177/1932296820911471] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This is a summary report of the most important aspects discussed during the YSI 2300 Analyzer Replacement Meeting. The aim is to provide the interested reader with an overview of the complex topic and propose solutions for the current issue. This solution should not only be adequate for the United States or Europe markets but also for all other countries. The meeting addendum presents three outcomes of the meeting.
Collapse
|
31
|
Abstract
Trans-fatty acid (TFA) intake can increase the risk of coronary heart disease (CHD) morbidity and mortality and all-cause mortality. Industrially produced TFAs and ruminant TFAs are the major sources in foods. TFA intake and TFA-attributed CHD mortality vary widely worldwide. Excessive TFA intake is a health threat in high-income countries; however, it is also a threat in low- and middle-income countries (LMICs). Data on TFA intake are scarce in many LMICs and an urgent need exists to monitor TFAs globally. We reviewed global TFA intake and TFA-attributed CHD mortality and current progress toward policy or regulation on elimination of industrially produced TFAs in foods worldwide. Human biological tissues can be used as biomarkers of TFAs because they reflect actual intake from various foods. Measuring blood TFA levels is a direct and reliable method to quantify TFA intake.
Collapse
|
32
|
Carlson L, Flores Poccia V, Sun BZ, Mosley B, Kirste I, Rice A, Sridhar R, Kangarloo T, Vesper HW, Duke L, Botelho JC, Filie AC, Adams JM, Shaw ND. Early breast development in overweight girls: does estrogen made by adipose tissue play a role? Int J Obes (Lond) 2019; 43:1978-1987. [PMID: 31462689 PMCID: PMC6774855 DOI: 10.1038/s41366-019-0446-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 07/09/2019] [Accepted: 07/22/2019] [Indexed: 11/10/2022]
Abstract
Background Girls who are overweight/obese (OB) develop breast tissue but do not
undergo menarche (the first menstrual period) significantly earlier than
girls of normal weight (NW). It has been proposed that estrogen synthesized
by adipose tissue may be contributory, yet OB do not have higher serum
estrogen levels than NW matched on breast stage. We hypothesized that
estrogen synthesized locally, in mammary fat, may contribute to breast
development. This hypothesis would predict that breast development would be
more advanced than other estrogen-sensitive tissues as a function of obesity
and body fat. Methods 80 pre-menarchal girls (26 OB, 54 NW), aged 8.2–14.7 yrs,
underwent dual-energy x-ray absorptiometry to calculate percent body fat
(%BF), Tanner staging of the breast, breast ultrasound for morphological
staging, trans-abdominal pelvic ultrasound, hand x-ray (bone age), a blood
test for reproductive hormones, and urine collection to determine the
vaginal maturation index (VMI), an index of estrogen exposure in urogenital
epithelial cells. Results When controlling for breast morphological stage determined by
ultrasound, %BF was not associated with serum estrogen or gonadotropin (LH
and FSH) levels or on indices of systemic estrogen action (uterine volume,
endometrial thickness, bone age advancement, and VMI). Tanner breast stage
did not correlate with breast morphological stage and led to
misclassification of chest fatty tissue as breast tissue in some OB. Conclusions These studies do not support the hypothesis that estrogen derived
from total body fat or local (mammary) fat contributes to breast development
in overweight/obese girls.
Collapse
|
33
|
Duke L, Kim PH, Botelho JC, Zhou H, Ulmer CZ, Vesper HW. Abstract 587: Highly sensitive and accurate method for measuring serum estradiol in postmenopausal women and other population subgroups. Cancer Res 2019. [DOI: 10.1158/1538-7445.am2019-587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Meta-analyses consistently show that postmenopausal women with elevated levels of estradiol have an increased risk for certain cancers, such as breast cancer. At the same time, estradiol therapy is used to treat menopausal symptoms. Data on blood levels of estradiol are highly variable, especially in postmenopausal women, which prevents the formulation of generally recognized normal ranges and the consistent treatment of postmenopausal women. Similarly, no generally recognized reference ranges for estradiol exist for men and children. One reason for this variability in estradiol blood levels is the lack of appropriate analytical methods. To overcome these challenges, new, highly sensitive, specific, and standardized methods for measuring estradiol are needed. This study describes a new analytical method for measuring estradiol in serum from post and premenopausal women, men and children, which is standardized to the CDC Hormone Standardization Program (HoSt). Data produced by this analytical method can be compared with data produced by other methods standardized to CDC HoSt. The analytical method optimizes the extraction of estradiol from serum using two liquid-liquid extractions with pH and polarity adjustments prior to LC-MS/MS analysis. All sample handling and extraction procedures are automated using 96-well plates. Chromatographic separation is carried out using a phenyl-hexyl HPLC column and a gradient of methanol and methanol:water. E2 and its C13 internal standard were analyzed by selected reaction monitoring (SRM) in the negative ion mode with transitions of m/z 271 to 145 and 274 to 148, respectively.
The mean biases of this method to certified reference materials ranged between −1.3% and −1.7% and were statistically not significant. No significant difference to established metrological reference methods was determined. The limit of detection for estradiol using 200 µL of serum is 11.0 pM (2.99 pg/mL). The method is highly precise with a within-run, among-day (determined over 68 days), and total within-laboratory imprecision ranging between 2.9-5.0%, 1.5-1.8%, and 3.3-5.3% CV, respectively [1].
The sensitivity of the method was found to be suitable for determining estradiol levels in postmenopausal women, men, and children, and is being applied to measure estradiol in postmenopausal women in NHANES 2013-2014. Data generated by this method are comparable to those of other analytical methods that are standardized to the CDC HoSt program. This method allows for the development of generally recognized normal ranges of estradiol in postmenopausal women and other population subgroups.
References:
1. Zhou, Hui et al. “Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry” Analytical and bioanalytical chemistry vol. 409,25 (2017): 5943-5954.
Citation Format: Lumi Duke, Paul H. Kim, Julianne Cook Botelho, Hui Zhou, Candice Z. Ulmer, Hubert W. Vesper. Highly sensitive and accurate method for measuring serum estradiol in postmenopausal women and other population subgroups [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2019; 2019 Mar 29-Apr 3; Atlanta, GA. Philadelphia (PA): AACR; Cancer Res 2019;79(13 Suppl):Abstract nr 587.
Collapse
|
34
|
Wright M, McKelvey W, Curtis CJ, Thorpe LE, Vesper HW, Kuiper HC, Angell SY. Impact of a Municipal Policy Restricting Trans Fatty Acid Use in New York City Restaurants on Serum Trans Fatty Acid Levels in Adults. Am J Public Health 2019; 109:634-636. [PMID: 30789777 DOI: 10.2105/ajph.2018.304930] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
OBJECTIVES To estimate the impact of the 2006 policy restricting use of trans fatty acids (TFAs) in New York City restaurants on change in serum TFA concentrations in New York City adults. METHODS Two cross-sectional population-based New York City Health and Nutrition Examination Surveys conducted in 2004 (n = 212) and 2013-2014 (n = 247) provided estimates of serum TFA exposure and average frequency of weekly restaurant meals. We estimated the geometric mean of the sum of serum TFAs by year and restaurant meal frequency by using linear regression. RESULTS Among those who ate less than 1 restaurant meal per week, geometric mean of the sum of serum TFAs declined 51.1% (95% confidence interval [CI] = 42.7, 58.3)-from 44.6 (95% CI = 39.7, 50.1) to 21.8 (95% CI = 19.3, 24.5) micromoles per liter. The decline in the geometric mean was greater (P for interaction = .04) among those who ate 4 or more restaurant meals per week: 61.6% (95% CI = 55.8, 66.7) or from 54.6 (95% CI = 49.3, 60.5) to 21.0 (95% CI = 18.9, 23.3) micromoles per liter. CONCLUSIONS New York City adult serum TFA concentrations declined between 2004 and 2014. The indication of greater decline in serum TFAs among those eating restaurant meals more frequently suggests that the municipal restriction on TFA use was effective in reducing TFA exposure. Public Health Implications. Local policies focused on restaurants can promote nutritional improvements.
Collapse
|
35
|
Zahoor N, Danilenko U, Vesper HW. A fully automated high-throughput liquid chromatography tandem mass spectrometry method for measuring creatinine in urine. CLINICAL MASS SPECTROMETRY (DEL MAR, CALIF.) 2019; 11:1-7. [PMID: 34414261 PMCID: PMC8372835 DOI: 10.1016/j.clinms.2018.11.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 11/16/2018] [Accepted: 11/19/2018] [Indexed: 10/27/2022]
Abstract
Reliable creatinine measurements are important to evaluate kidney function and for creatinine correction to reduce biological variability of other urinary analytes. A high-throughput, accurate liquid chromatography tandem mass spectrometry method for quantitation of human urinary creatinine has been developed and validated. Sample preparation was fully automated including cryovial decapping, sample ID scanning and two serial dilution steps. Quantitation was performed using a stable isotope-labeled internal standard. Multiplexed chromatographic separation of creatinine was achieved within a one-minute analysis and followed by tandem mass spectrometry in positive electrospray ionization mode. The precursor and product ions of creatinine and D3-creatinine were monitored in selected reaction monitoring mode. Method validation results showed reproducibility with within-run precision of 3.59, 3.49 and 2.84% and between-run precision of 4.01, 3.28 and 3.57% for low, medium and high quality control materials prepared from pooled donor urine, respectively. The method showed excellent accuracy with a bias of -1.94%, -0.78% and -1.07% for three levels of certified reference material. The calibration curve was linear throughout a 7.50-300 mg/dL (0.663-26.5 mmol/L) measurement range (R2 = 0.999), with the mean slope of 0.0115 (95%CI, 0.0108-0.0122) and intercept of 0.0027 (95%CI, 0.0003-0.0051). The limit of detection (LOD) of the method was 3.17 mg/dL (0.280 mmol/L). Analytical specificity was achieved by chromatographically separating creatinine from potentially interfering creatine within a one-minute run and monitoring the Quantitation Ion/Confirmation Ion (QI/CI) ratios in samples. A simple, accurate, high-throughput method was successfully developed for measuring creatinine in human urine samples.
Collapse
|
36
|
Delatour V, Liu Q, Vesper HW. Commutability Assessment of External Quality Assessment Materials with the Difference in Bias Approach: Are Acceptance Criteria Based on Medical Requirements too Strict? Clin Chem 2018; 62:1670-1671. [PMID: 27899458 DOI: 10.1373/clinchem.2016.261008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
37
|
Delatour V, Clouet-Foraison N, Gaie-Levrel F, Marcovina SM, Hoofnagle AN, Kuklenyik Z, Caulfield MP, Otvos JD, Krauss RM, Kulkarni KR, Contois JH, Remaley AT, Vesper HW, Cobbaert CM, Gillery P. Comparability of Lipoprotein Particle Number Concentrations Across ES-DMA, NMR, LC-MS/MS, Immunonephelometry, and VAP: In Search of a Candidate Reference Measurement Procedure for apoB and non-HDL-P Standardization. Clin Chem 2018; 64:1485-1495. [PMID: 30087138 DOI: 10.1373/clinchem.2018.288746] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Accepted: 07/10/2018] [Indexed: 12/15/2022]
Abstract
BACKGROUND Despite the usefulness of standard lipid parameters for cardiovascular disease risk assessment, undiagnosed residual risk remains high. Advanced lipoprotein testing (ALT) was developed to provide physicians with more predictive diagnostic tools. ALT methods separate and/or measure lipoproteins according to different parameters such as size, density, charge, or content, and equivalence of results across methods has not been demonstrated. METHODS Through a split-sample study, 25 clinical specimens (CSs) were assayed in 10 laboratories before and after freezing using the major ALT methods for non-HDL particles (non-HDL-P) or apolipoprotein B-100 (apoB-100) measurements with the intent to assess their comparability in the current state of the art. RESULTS The overall relative standard deviation (CV) of non-HDL-P and apoB-100 concentrations measured by electrospray differential mobility analysis, nuclear magnetic resonance, immunonephelometry, LC-MS/MS, and vertical autoprofile in the 25 frozen CSs was 14.1%. Within-method comparability was heterogeneous, and CV among 4 different LC-MS/MS methods was 11.4% for apoB-100. No significant effect of freezing and thawing was observed. CONCLUSIONS This study demonstrates that ALT methods do not yet provide equivalent results for the measurement of non-HDL-P and apoB-100. The better agreement between methods harmonized to the WHO/IFCC reference material suggests that standardizing ALT methods by use of a common commutable calibrator will improve cross-platform comparability. This study provides further evidence that LC-MS/MS is the most suitable candidate reference measurement procedure to standardize apoB-100 measurement, as it would provide results with SI traceability. The absence of freezing and thawing effect suggests that frozen serum pools could be used as secondary reference materials.
Collapse
|
38
|
Adgent MA, Umbach DM, Zemel BS, Kelly A, Schall JI, Ford EG, James K, Darge K, Botelho JC, Vesper HW, Chandler DW, Nakamoto JM, Rogan WJ, Stallings VA. A Longitudinal Study of Estrogen-Responsive Tissues and Hormone Concentrations in Infants Fed Soy Formula. J Clin Endocrinol Metab 2018; 103:1899-1909. [PMID: 29506126 PMCID: PMC6456922 DOI: 10.1210/jc.2017-02249] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 02/26/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE Chemicals with hormonelike activity, such as estrogenic isoflavones, may perturb human development. Infants exclusively fed soy-based formula are highly exposed to isoflavones, but their physiologic responses remain uncharacterized. Estrogen-responsive postnatal development was compared in infants exclusively fed soy formula, cow-milk formula, and breast milk. METHODS We enrolled 410 infants born in Philadelphia-area hospitals between 2010 and 2014; 283 were exclusively fed soy formula (n = 102), cow-milk formula (n = 111), or breast milk (n = 70) throughout the study (birth to 28 or 36 weeks for boys and girls, respectively). We repeatedly measured maturation index (MI) in vaginal and urethral epithelial cells using standard cytological methods, uterine volume and breast-bud diameter using ultrasound, and serum estradiol and follicle-stimulating hormone levels. We estimated MI, organ-growth, and hormone trajectories by diet using mixed-effects regression splines. RESULTS Maternal demographics did not differ between cow-milk-fed and soy-fed infants but did differ between formula-fed and breastfed infants. Vaginal-cell MI trended higher (P = 0.01) and uterine volume decreased more slowly (P = 0.01) in soy-fed girls compared with cow-milk-fed girls; however, their trajectories of breast-bud diameter and hormone concentrations did not differ. We observed no significant differences between boys fed cow-milk vs soy formula; estradiol was not detectable. Breastfed infants differed from soy-formula-fed infants in vaginal-cell MI, uterine volume, and girls' estradiol and boys' breast-bud diameter trajectories. CONCLUSIONS Relative to girls fed cow-milk formula, those fed soy formula demonstrated tissue- and organ-level developmental trajectories consistent with response to exogenous estrogen exposure. Studies are needed to further evaluate the effects of soy on child development.
Collapse
|
39
|
Miller WG, Schimmel H, Rej R, Greenberg N, Ceriotti F, Burns C, Budd JR, Weykamp C, Delatour V, Nilsson G, MacKenzie F, Panteghini M, Keller T, Camara JE, Zegers I, Vesper HW. IFCC Working Group Recommendations for Assessing Commutability Part 1: General Experimental Design. Clin Chem 2018; 64:447-454. [PMID: 29348163 DOI: 10.1373/clinchem.2017.277525] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 12/14/2017] [Indexed: 11/06/2022]
Abstract
Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.
Collapse
|
40
|
Nilsson G, Budd JR, Greenberg N, Delatour V, Rej R, Panteghini M, Ceriotti F, Schimmel H, Weykamp C, Keller T, Camara JE, Burns C, Vesper HW, MacKenzie F, Miller WG. IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical Samples. Clin Chem 2018; 64:455-464. [PMID: 29348165 DOI: 10.1373/clinchem.2017.277541] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 12/15/2017] [Indexed: 11/06/2022]
Abstract
A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.
Collapse
|
41
|
Budd JR, Weykamp C, Rej R, MacKenzie F, Ceriotti F, Greenberg N, Camara JE, Schimmel H, Vesper HW, Keller T, Delatour V, Panteghini M, Burns C, Miller WG. IFCC Working Group Recommendations for Assessing Commutability Part 3: Using the Calibration Effectiveness of a Reference Material. Clin Chem 2018; 64:465-474. [PMID: 29348164 DOI: 10.1373/clinchem.2017.277558] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 12/18/2017] [Indexed: 11/06/2022]
Abstract
A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrated.
Collapse
|
42
|
Kuiper HC, Wei N, McGunigale SL, Vesper HW. Quantitation of trans-fatty acids in human blood via isotope dilution-gas chromatography-negative chemical ionization-mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1076:35-43. [PMID: 29396366 DOI: 10.1016/j.jchromb.2017.12.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 12/27/2017] [Accepted: 12/30/2017] [Indexed: 12/14/2022]
Abstract
Trans-fatty acids (TFA) are geometric isomers of naturally occurring cis-fatty acids. High dietary TFA intake has been associated with risk factors for cardiovascular disease. However, little is known about TFA levels in humans. To address this data need, we developed and validated a new isotope dilution-gas chromatography-negative chemical ionization-mass spectrometry (ID-GC-NCI-MS) method for quantitation of 27 fatty acids (FA) including 4 major TFA in human plasma, serum, and red blood cells (RBC) from 66 donors. Quantitation was performed with 18 isotope labeled internal standards and results are presented in μM and % of total FA. This method has high sensitivity and specificity due to use of pentafluorobenzyl-bromide derivatization combined with NCI-MS and a 200m column to optimize positional and geometric FA isomer separation. The four major TFA, palmitelaidic acid, elaidic acid, trans-vaccenic acid, and linoelaidic acid, were detected in all samples, with median total TFA concentrations of 17.7μM in plasma, 19.6μM in serum, and 21.5μM in RBC. The % of total FA for the TFA was 0.20% in plasma, 0.20% in serum, and 0.30% in RBC. Patterns for % FA are similar to those reported in other studies. We developed a highly specific, ID-GC-NCI-MS method to quantitate TFA and other FA in humans.
Collapse
|
43
|
Yang M, Ospina M, Tse C, Toth S, Caudill SP, Vesper HW. Ultraperformance Liquid Chromatography Tandem Mass Spectrometry Method To Determine Formaldehyde Hemoglobin Adducts in Humans as Biomarker for Formaldehyde Exposure. Chem Res Toxicol 2017; 30:1592-1598. [PMID: 28662331 PMCID: PMC5652314 DOI: 10.1021/acs.chemrestox.7b00114] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Formaldehyde (FA) is an environmental chemical classified as a human carcinogen. It is highly reactive and can bind covalently with hemoglobin (Hb) to produce Hb adducts. Measurement of these Hb adducts provides valuable information about exposure to this chemical. We developed a robust, ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for quantifying FA-Hb adducts in red blood cells. The method measures the FA-VHLTPEEK peptide after trypic digestion. The peptide is a FA adduct at the N-terminus of the beta chain of human Hb. Method mean (±SD) accuracy, determined by recovery in quality control and blank material was 103.2% ± 8.11. The mean among-day and within-day coefficients of variation determined at three concentration levels (%CV) were 9.2% (range: 7.2-10.2%) and 4.9% (range 3.1-7.3%), respectively. The limit of detection was 3.4 nmol/g Hb. This method was applied to the analysis of 135 human blood samples, and FA-VHLTPEEK was detected in all study samples. FA-VHLTPEEK concentrations were not significantly different between smokers and nonsmokers. This work is the first validated UPLC-MS/MS method in which a FA peptide derived from a FA-Hb adduct could be used to monitor exposure to FA in population studies.
Collapse
|
44
|
Zhou H, Wang Y, Gatcombe M, Farris J, Botelho JC, Caudill SP, Vesper HW. Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2017; 409:5943-5954. [PMID: 28801832 DOI: 10.1007/s00216-017-0529-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 07/05/2017] [Accepted: 07/18/2017] [Indexed: 12/13/2022]
Abstract
Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.
Collapse
|
45
|
Vesper HW, Caudill SP, Kuiper HC, Yang Q, Ahluwalia N, Lacher DA, Pirkle JL. Plasma trans-fatty acid concentrations in fasting adults declined from NHANES 1999-2000 to 2009-2010. Am J Clin Nutr 2017; 105:1063-1069. [PMID: 28381474 PMCID: PMC5708855 DOI: 10.3945/ajcn.116.141622] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Accepted: 03/06/2017] [Indexed: 01/20/2023] Open
Abstract
Background: The consumption of trans fatty acids (TFAs) is associated with an increased risk of cardiovascular disease, and reducing their consumption is a major public health objective. Food intake studies have provided estimates for TFA concentrations in the US population; however, there is a need for data on TFA blood concentrations in the population.Objective: The objective of this study was to determine plasma TFA concentrations in a nationally representative group of fasted adults in the US population in NHANES samples from 1999-2000 and 2009-2010.Design: Four major TFAs [palmitelaidic acid (C16:1n-7t), trans vaccenic acid (C18:1n-7t), elaidic acid (C18:1n-9t), and linoelaidic acid (C18:2n-6t,9t)] were measured in plasma in 1613 subjects from NHANES 1999-2000 and 2462 subjects from NHANES 2009-2010 by gas chromatography-mass spectrometry. Geometric means and distribution percentiles were calculated for each TFA and their sum by age, sex, and race/ethnicity (non-Hispanic white, non-Hispanic black, Mexican American), and covariate-adjusted geometric means were computed by using a model that included these demographic and other dietary factors, as well as survey year and any significant interaction terms.Results: These nationally representative data for the adult US population show that TFA concentrations were 54% lower in NHANES 2009-2010 than in NHANES 1999-2000. Covariate-adjusted geometric means for the sum of the 4 TFAs were 81.4 μmol/L (95% CI: 77.3, 85.6 μmol/L) and 37.8 μmol/L (95% CI: 36.4, 39.4 μmol/L) in NHANES 1999-2000 and 2009-2010, respectively. Even with the large decline in TFA concentrations, differences between demographic subgroups were comparable in the 2 surveys.Conclusion: The results indicate an overall reduction in TFA concentrations in the US population and provide a valuable baseline to evaluate the impact of the recent regulation categorizing TFAs as food additives.
Collapse
|
46
|
Travison TG, Vesper HW, Orwoll E, Wu F, Kaufman JM, Wang Y, Lapauw B, Fiers T, Matsumoto AM, Bhasin S. Harmonized Reference Ranges for Circulating Testosterone Levels in Men of Four Cohort Studies in the United States and Europe. J Clin Endocrinol Metab 2017; 102:1161-1173. [PMID: 28324103 PMCID: PMC5460736 DOI: 10.1210/jc.2016-2935] [Citation(s) in RCA: 163] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Accepted: 11/18/2016] [Indexed: 02/04/2023]
Abstract
Background Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator.
Collapse
|
47
|
Legro RS, Kunselman AR, Stetter CM, Gnatuk CL, Estes SJ, Brindle E, Vesper HW, Botelho JC, Lee PA, Dodson WC. Normal Pubertal Development in Daughters of Women With PCOS: A Controlled Study. J Clin Endocrinol Metab 2017; 102:122-131. [PMID: 27778640 PMCID: PMC5413094 DOI: 10.1210/jc.2016-2707] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 10/21/2016] [Indexed: 11/19/2022]
Abstract
CONTEXT Daughters of women with polycystic ovary syndrome (PCOS) are thought to be at increased risk for developing stigmata of the syndrome, but the ontogeny during puberty is uncertain. OBJECTIVE We phenotyped daughters (n = 76) of mothers with PCOS and daughters (n = 80) from control mothers for reproductive and metabolic parameters characteristic of PCOS. DESIGN, SETTING, AND PARTICIPANTS We performed a matched case/control study at Penn State Hershey Medical Center that included non-Hispanic, white girls 4 to 17 years old. INTERVENTION We obtained birth history, biometric, ovarian ultrasounds, whole-body dual-energy X-ray absorptiometry scan for body composition, 2-hour glucose challenged salivary insulin levels, and two timed urinary collections (12 hours overnight and 3 hours in the morning) for gonadotropins and sex steroids. MAIN OUTCOME MEASURES We measured integrated urinary levels of adrenal (dehydroepiandrosterone sulfate) and ovarian [testosterone (TT)] steroids. Other endpoints included integrated salivary insulin levels and urinary luteinizing hormone levels. RESULTS There were no differences in detection rates or mean levels for gonadotropins and sex steroids in timed urinary collections between PCOS daughters and control daughters, nor were there differences in integrated salivary insulin levels. Results showed that 69% of Tanner 4/5 PCOS daughters vs 31% of control daughters had hirsutism defined as a Ferriman-Gallwey score >8 (P = 0.04). There were no differences in body composition as determined by dual-energy X-ray absorptiometry between groups in the three major body contents (i.e., bone, lean body mass, and fat) or in ovarian volume between groups. CONCLUSIONS Matched for pubertal stage, PCOS daughters have similar levels of urinary androgens and gonadotropins as well as glucose-challenged salivary insulin levels.
Collapse
|
48
|
Botelho JC, Ribera A, Cooper HC, Vesper HW. Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum. Anal Chem 2016; 88:11123-11129. [PMID: 27744701 DOI: 10.1021/acs.analchem.6b03220] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The inaccuracy of 17-β estradiol (E2) measurements affects its use as a biomarker in patient care and research. Clinical and research communities called for accurate and standardized E2 measurements. Reference Measurement Procedures (RMPs), part of the CDC Hormone Standardization Program (HoSt), are essential in addressing this need and ensuring that methods are accurate and comparable across testing systems, laboratories, and over time. A candidate RMP (cRMP) was developed for the measurement of total E2 in serum using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without derivatization. The cRMP meets suggested performance criteria for accuracy and precision through the use of isotope dilution, calibrator bracketing, and gravimetric measurements. The cRMP demonstrated high agreement with certified reference materials (no significant bias to BCR576, 577, and 578) and established RMPs (slope 1.00, 95% CI 1.00-1.01; intercept 0.02, 95% CI -0.01 to 0.06). The cRMP is highly precise with intra-assay, interassay, and total percent CVs of 2.7%, 1.3%, and 2.4%, respectively. A higher specificity was achieved by measuring E2 without derivatization, compared to methods using derivatization agents. The cRMP can serve as a higher-order standard for establishing measurement traceability and provides an accuracy base against which routine methods can be compared in HoSt.
Collapse
|
49
|
Sturgeon CM, Sprague S, Almond A, Cavalier E, Fraser WD, Algeciras-Schimnich A, Singh R, Souberbielle JC, Vesper HW. Perspective and priorities for improvement of parathyroid hormone (PTH) measurement - A view from the IFCC Working Group for PTH. Clin Chim Acta 2016; 467:42-47. [PMID: 27746210 DOI: 10.1016/j.cca.2016.10.016] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Revised: 10/11/2016] [Accepted: 10/12/2016] [Indexed: 11/15/2022]
Abstract
Parathyroid hormone (PTH) measurement in serum or plasma is a necessary tool for the exploration of calcium/phosphate disorders, and is widely used as a surrogate marker to assess skeletal and mineral disorders associated with chronic kidney disease (CKD), referred to as CKD-bone mineral disorders (CKD-MBD). CKD currently affects >10% of the adult population in the United States and represents a major health issue worldwide. Disturbances in mineral metabolism and fractures in CKD patients are associated with increased morbidity and mortality. Appropriate identification and management of CKD-MBD is therefore critical to improving clinical outcome. Recent increases in understanding of the complex pathophysiology of CKD, which involves calcium, phosphate and magnesium balance, and is also influenced by vitamin D status and fibroblast growth factor (FGF)-23 production, should facilitate such improvement. Development of evidence-based recommendations about how best to use PTH is limited by considerable method-related variation in results, of up to 5-fold, as well as by lack of clarity about which PTH metabolites these methods recognise. This makes it difficult to compare PTH results from different studies and to develop common reference intervals and/or decision levels for treatment. The implications of these method-related differences for current clinical practice are reviewed here. Work being undertaken by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) to improve the comparability of PTH measurements worldwide is also described.
Collapse
|
50
|
Nakamura M, Iso H, Kitamura A, Imano H, Noda H, Kiyama M, Sato S, Yamagishi K, Nishimura K, Nakai M, Vesper HW, Teramoto T, Miyamoto Y. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme. Ann Clin Biochem 2016; 53:632-639. [PMID: 26680645 DOI: 10.1177/0004563215624461] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.
Collapse
|