Matz G, Messerschmidt B, Göbel W, Filser S, Betz CS, Kirsch M, Uckermann O, Kunze M, Flämig S, Ehrhardt A, Irion KM, Haack M, Dorostkar MM, Herms J, Gross H. Chip-on-the-tip compact flexible endoscopic epifluorescence video-microscope for in-vivo imaging in medicine and biomedical research. BIOMEDICAL OPTICS EXPRESS 2017; 8:3329-3342. [PMID: 28717570 PMCID: PMC5508831 DOI: 10.1364/boe.8.003329] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 06/15/2017] [Accepted: 06/15/2017] [Indexed: 05/17/2023]
Abstract
We demonstrate a 60 mg light video-endomicroscope with a cylindrical shape of the rigid tip of only 1.6 mm diameter and 6.7 mm length. A novel implementation method of the illumination unit in the endomicroscope is presented. It allows for the illumination of the biological sample with fiber-coupled LED light at 455 nm and the imaging of the red-shifted fluorescence light above 500 nm in epi-direction. A large numerical aperture of 0.7 leads to a sub-cellular resolution and yields to high-contrast images within a field of view of 160 μm. A miniaturized chip-on-the-tip CMOS image sensor with more than 150,000 pixels captures the multicolor images at 30 fps. Considering size, plug-and-play capability, optical performance, flexibility and weight, we hence present a probe which sets a new benchmark in the field of epifluorescence endomicroscopes. Several ex-vivo and in-vivo experiments in rodents and humans suggest future application in biomedical fields, especially in the neuroscience community, as well as in medical applications targeting optical biopsies or the detection of cellular anomalies.
Collapse
|
27
|
Hasegawa M, Wandera EA, Inoue Y, Kimura N, Sasaki R, Mizukami T, Shah MM, Shirai N, Takei O, Shindo H, Ichinose Y. Detection of rotavirus in clinical specimens using an immunosensor prototype based on the photon burst counting technique. BIOMEDICAL OPTICS EXPRESS 2017; 8:3383-3394. [PMID: 28717574 PMCID: PMC5508835 DOI: 10.1364/boe.8.003383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 05/13/2017] [Accepted: 06/18/2017] [Indexed: 06/07/2023]
Abstract
In this study, a sensitive fluorescence sensor was developed for the detection of small, fluorescence-labeled particles dispersed in a solution. The prototype system comprises of a laser confocal optical system and a mechanical sample stage to detect photon bursting of fluorescence-labeled small particles in sample volumes less than 5 μL within 3 minutes. To examine the feasibility of the prototype system as a diagnostic tool, assemblages of rotavirus and fluorescence-labeled antibody were analyzed. The detection sensitivity for rotavirus was 1 × 104 pfu/mL. Rotavirus in stool samples from patients with acute gastroenteritis was also detected. The advantages and disadvantages of this immunosensor with respect to ELISA and RT-PCR, the current gold standards for virus detection, are discussed.
Collapse
|
28
|
Binzoni T, Sassaroli A, Torricelli A, Spinelli L, Farina A, Durduran T, Cavalieri S, Pifferi A, Martelli F. Depth sensitivity of frequency domain optical measurements in diffusive media. BIOMEDICAL OPTICS EXPRESS 2017; 8:2990-3004. [PMID: 28663921 PMCID: PMC5480444 DOI: 10.1364/boe.8.002990] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 04/13/2017] [Accepted: 04/18/2017] [Indexed: 05/03/2023]
Abstract
The depth sensitivity functions for AC amplitude, phase (PH) and DC intensity signals have been obtained in the frequency domain (where the source amplitude is modulated at radio-frequencies) by making use of analytical solutions of the photon diffusion equation in an infinite slab geometry. Furthermore, solutions for the relative contrast of AC, PH and DC signals when a totally absorbing plane is placed at a fixed depth of the slab have also been obtained. The solutions have been validated by comparisons with gold standard Monte Carlo simulations. The obtained results show that the AC signal, for modulation frequencies < 200 MHz, has a depth sensitivity with similar characteristics to that of the continuous-wave (CW) domain (source modulation frequency of zero). Thus, the depth probed by such a signal can be estimated by using the formula of penetration depth for the CW domain (Sci. Rep.6, 27057 (2016)). However, the PH signal has a different behavior compared to the CW domain, showing a larger depth sensitivity at shallow depths and a less steep relative contrast as a function of depth. These results mark a clear difference in term of depth sensitivity between AC and PH signals, and highlight the complexity of the estimation of the actual depth probed in tissue spectroscopy.
Collapse
|
29
|
Makita S, Yasuno Y. Detection of local tissue alteration during retinal laser photocoagulation of ex vivo porcine eyes using phase-resolved optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2017; 8:3067-3080. [PMID: 28663927 PMCID: PMC5480450 DOI: 10.1364/boe.8.003067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 05/17/2017] [Accepted: 05/17/2017] [Indexed: 05/03/2023]
Abstract
Retinal laser photocoagulation is used to treat several ophthalmic diseases. However, it is associated with damage to surrounding healthy tissue. Local tissue alteration during coagulation laser illumination was measured using phase-resolved optical coherence tomography (OCT) M-mode scan as a change in the local optical path length (LOPL). A metric that represents global net tissue alteration was defined using the LOPL change. The visibility of a laser lesion was assessed by three-dimensional OCT volume measurement. Multiple logistic regression analysis was performed to investigate the association between the introduced metric and the laser lesion visibility. The metric was found to be a statistically significant predictor of the laser lesion visibility independent to laser condition. The proposed method based on an LOPL change is thus promising for retinal photocoagulation monitoring.
Collapse
|
30
|
Farzam P, Johansson J, Mireles M, Jiménez-Valerio G, Martínez-Lozano M, Choe R, Casanovas O, Durduran T. Pre-clinical longitudinal monitoring of hemodynamic response to anti-vascular chemotherapy by hybrid diffuse optics. BIOMEDICAL OPTICS EXPRESS 2017; 8:2563-2582. [PMID: 28663891 PMCID: PMC5480498 DOI: 10.1364/boe.8.002563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 03/20/2017] [Accepted: 03/30/2017] [Indexed: 05/20/2023]
Abstract
The longitudinal effect of an anti-vascular endothelial growth factor receptor 2 (VEGFR-2) antibody (DC 101) therapy on a xenografted renal cell carcinoma (RCC) mouse model was monitored using hybrid diffuse optics. Two groups of immunosuppressed male nude mice (seven treated, seven controls) were measured. Tumor microvascular blood flow, total hemoglobin concentration and blood oxygenation were investigated as potential biomarkers for the monitoring of the therapy effect twice a week and were related to the final treatment outcome. These hemodynamic biomarkers have shown a clear differentiation between two groups by day four. Moreover, we have observed that pre-treatment values and early changes in hemodynamics are highly correlated with the therapeutic outcome demonstrating the potential of diffuse optics to predict the therapy response at an early time point.
Collapse
|
31
|
Sexton KJ, Zhao Y, Davis SC, Jiang S, Pogue BW. Optimization of fluorescent imaging in the operating room through pulsed acquisition and gating to ambient background cycling. BIOMEDICAL OPTICS EXPRESS 2017; 8:2635-2648. [PMID: 28663895 PMCID: PMC5480502 DOI: 10.1364/boe.8.002635] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 04/15/2017] [Accepted: 04/18/2017] [Indexed: 05/03/2023]
Abstract
The design of fluorescence imaging instruments for surgical guidance is rapidly evolving, and a key issue is to efficiently capture signals with high ambient room lighting. Here, we introduce a novel time-gated approach to fluorescence imaging synchronizing acquisition to the 120 Hz light of the room, with pulsed LED excitation and gated ICCD detection. It is shown that under bright ambient room light this technique allows for the detection of physiologically relevant nanomolar fluorophore concentrations, and in particular reduces the light fluctuations present from the room lights, making low concentration measurements more reliable. This is particularly relevant for the light bands near 700nm that are more dominated by ambient lights.
Collapse
|
32
|
Bu R, Balakrishnan S, Iftimia N, Price H, Zdanski C, Oldenburg AL. Airway compliance measured by anatomic optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2017; 8:2195-2209. [PMID: 28736665 PMCID: PMC5516819 DOI: 10.1364/boe.8.002195] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 02/16/2017] [Accepted: 03/10/2017] [Indexed: 05/25/2023]
Abstract
Quantification of airway compliance can aid in the diagnosis and treatment of obstructive airway disorders by detecting regions vulnerable to collapse. Here we evaluate the ability of a swept-source anatomic optical coherence tomography (SSaOCT) system to quantify airway cross-sectional compliance (CC) by measuring changes in the luminal cross-sectional area (CSA) under physiologically relevant pressures of 10-40 cmH2O. The accuracy and precision of CC measurements are determined using simulations of non-uniform rotation distortion (NURD) endemic to endoscopic scanning, and experiments performed in a simplified tube phantom and ex vivo porcine tracheas. NURD simulations show that CC measurements are typically more accurate than that of the CSAs from which they are derived. Phantom measurements of CSA versus pressure exhibit high linearity (R2>0.99), validating the dynamic range of the SSaOCT system. Tracheas also exhibited high linearity (R2 = 0.98) suggestive of linear elasticity, while CC measurements were obtained with typically ± 12% standard error.
Collapse
|
33
|
Shadfan A, Darwiche H, Blanco J, Gillenwater A, Richards-Kortum R, Tkaczyk TS. Development of a multimodal foveated endomicroscope for the detection of oral cancer. BIOMEDICAL OPTICS EXPRESS 2017; 8:1525-1535. [PMID: 28663847 PMCID: PMC5480562 DOI: 10.1364/boe.8.001525] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 02/06/2017] [Accepted: 02/06/2017] [Indexed: 05/11/2023]
Abstract
A multimodal endomicroscope was developed for cancer detection that combines hyperspectral and confocal imaging through a single foveated objective and a vibrating optical fiber bundle. Standard clinical examination has a limited ability to identify early stage oral cancer. Optical detection methods are typically restricted by either achievable resolution or a small field-of-view. By combining high resolution and widefield spectral imaging into a single probe, a device was developed that provides spectral and spatial information over a 5 mm field to locate suspicious lesions that can then be inspected in high resolution mode. The device was evaluated on ex vivo biopsies of human oral tumors.
Collapse
|
34
|
Kasaragod D, Makita S, Hong YJ, Yasuno Y. Noise stochastic corrected maximum a posteriori estimator for birefringence imaging using polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2017; 8:653-669. [PMID: 28270974 PMCID: PMC5330548 DOI: 10.1364/boe.8.000653] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 12/22/2016] [Accepted: 12/27/2016] [Indexed: 05/05/2023]
Abstract
This paper presents a noise-stochastic corrected maximum a posteriori estimator for birefringence imaging using Jones matrix optical coherence tomography. The estimator described in this paper is based on the relationship between probability distribution functions of the measured birefringence and the effective signal to noise ratio (ESNR) as well as the true birefringence and the true ESNR. The Monte Carlo method is used to numerically describe this relationship and adaptive 2D kernel density estimation provides the likelihood for a posteriori estimation of the true birefringence. Improved estimation is shown for the new estimator with stochastic model of ESNR in comparison to the old estimator, both based on the Jones matrix noise model. A comparison with the mean estimator is also done. Numerical simulation validates the superiority of the new estimator. The superior performance of the new estimator was also shown by in vivo measurement of optic nerve head.
Collapse
|
35
|
Cernat R, Bradu A, Israelsen NM, Bang O, Rivet S, Keane PA, Heath DG, Rajendram R, Podoleanu A. Gabor fusion master slave optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2017; 8:813-827. [PMID: 28270987 PMCID: PMC5330593 DOI: 10.1364/boe.8.000813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 01/06/2017] [Accepted: 01/06/2017] [Indexed: 06/01/2023]
Abstract
This paper describes the application of the Gabor filtering protocol to a Master/Slave (MS) swept source optical coherence tomography (SS)-OCT system at 1300 nm. The MS-OCT system delivers information from selected depths, a property that allows operation similar to that of a time domain OCT system, where dynamic focusing is possible. The Gabor filtering processing following collection of multiple data from different focus positions is different from that utilized by a conventional swept source OCT system using a Fast Fourier transform (FFT) to produce an A-scan. Instead of selecting the bright parts of A-scans for each focus position, to be placed in a final B-scan image (or in a final volume), and discarding the rest, the MS principle can be employed to advantageously deliver signal from the depths within each focus range only. The MS procedure is illustrated on creating volumes of data of constant transversal resolution from a cucumber and from an insect by repeating data acquisition for 4 different focus positions. In addition, advantage is taken from the tolerance to dispersion of the MS principle that allows automatic compensation for dispersion created by layers above the object of interest. By combining the two techniques, Gabor filtering and Master/Slave, a powerful imaging instrument is demonstrated. The master/slave technique allows simultaneous display of three categories of images in one frame: multiple depth en-face OCT images, two cross-sectional OCT images and a confocal like image obtained by averaging the en-face ones. We also demonstrate the superiority of MS-OCT over its FFT based counterpart when used with a Gabor filtering OCT instrument in terms of the speed of assembling the fused volume. For our case, we show that when more than 4 focus positions are required to produce the final volume, MS is faster than the conventional FFT based procedure.
Collapse
|
36
|
Sajjadi AY, Isakoff SJ, Deng B, Singh B, Wanyo CM, Fang Q, Specht MC, Schapira L, Moy B, Bardia A, Boas DA, Carp SA. Normalization of compression-induced hemodynamics in patients responding to neoadjuvant chemotherapy monitored by dynamic tomographic optical breast imaging (DTOBI). BIOMEDICAL OPTICS EXPRESS 2017; 8:555-569. [PMID: 28270967 PMCID: PMC5330555 DOI: 10.1364/boe.8.000555] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 11/04/2016] [Accepted: 12/05/2016] [Indexed: 05/03/2023]
Abstract
We characterize novel breast cancer imaging biomarkers for monitoring neoadjuvant chemotherapy (NACT) and predicting outcome. Specifically, we recruited 30 patients for a pilot study in which NACT patients were imaged using dynamic tomographic optical breast imaging (DTOBI) to quantify the hemodynamic changes due to partial mammographic compression. DTOBI scans were obtained pre-treatment (referred to as day 0), as well as 7 and 30 days into therapy on female patients undergoing NACT. We present data for the 13 patients who participated in both day 0 and 7 measurements and had evaluable data, of which 7 also returned for day 30 measurements. We acquired optical images over 2 minutes following 4-8 lbs (18-36 N) of compression. The timecourses of tissue-volume averaged total hemoglobin (HbT), as well as hemoglobin oxygen saturation (SO2) in the tumor vs. surrounding tissues were compared. Outcome prediction metrics based on the differential behavior in tumor vs. normal areas for responders (>50% reduction in maximum diameter) vs. non-responders were analyzed for statistical significance. At baseline, all patients exhibit an initial decrease followed by delayed recovery in HbT, and SO2 in the tumor area, in contrast to almost immediate recovery in surrounding tissue. At day 7 and 30, this contrast is maintained in non-responders; however, in responders, the contrast in hemodynamic time-courses between tumor and normal tissue starts decreasing at day 7 and substantially disappears at day 30. At day 30 into NACT, responding tumors demonstrate "normalization" of compression induced hemodynamics vs. surrounding normal tissue whereas non-responding tumors did not. This data suggests that DTOBI imaging biomarkers, which are governed by the interplay between tissue biomechanics and oxygen metabolism, may be suitable for guiding NACT by offering early predictions of treatment outcome.
Collapse
|
37
|
Pence IJ, Beaulieu DB, Horst SN, Bi X, Herline AJ, Schwartz DA, Mahadevan-Jansen A. Clinical characterization of in vivo inflammatory bowel disease with Raman spectroscopy. BIOMEDICAL OPTICS EXPRESS 2017; 8:524-535. [PMID: 28270965 PMCID: PMC5330549 DOI: 10.1364/boe.8.000524] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 11/23/2016] [Accepted: 11/24/2016] [Indexed: 05/05/2023]
Abstract
Inflammatory bowel disease (IBD), including ulcerative colitis (UC) and Crohn's disease (CD), affects over 1 million Americans and 2 million Europeans, and the incidence is increasing worldwide. While these diseases require unique medical care, the differentiation between UC and CD lacks a gold standard, and therefore relies on long term follow up, success or failure of existing treatment, and recurrence of the disease. Here, we present colonoscopy-coupled fiber optic probe-based Raman spectroscopy as a minimally-invasive diagnostic tool for IBD of the colon (UC and Crohn's colitis). This pilot in vivo study of subjects with existing IBD diagnoses of UC (n = 8), CD (n = 15), and normal control (n = 8) aimed to characterize spectral signatures of UC and CD. Samples were correlated with tissue pathology markers and endoscopic evaluation. The collected spectra were processed and analyzed using multivariate statistical techniques to identify spectral markers and discriminate IBD and disease classes. Confounding factors including the presence of active inflammation and the particular colon segment measured were investigated and integrated into the devised prediction algorithm, reaching 90% sensitivity and 75% specificity to CD from this in vivo data set. These results represent significant progress towards improved real-time classification for accurate and automated in vivo detection and discrimination of IBD during colonoscopy procedures.
Collapse
|
38
|
Song Y, Garcia S, Frometa Y, Ramella-Roman JC, Soltani M, Almadi M, Riera JJ, Lin WC. Quantitative assessment of hemodynamic and structural characteristics of in vivo brain tissue using total diffuse reflectance spectrum measured in a non-contact fashion. BIOMEDICAL OPTICS EXPRESS 2017; 8:78-103. [PMID: 28101403 PMCID: PMC5231317 DOI: 10.1364/boe.8.000078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 11/03/2016] [Accepted: 11/08/2016] [Indexed: 05/03/2023]
Abstract
Here we present a new methodology that investigates the intrinsic structural and hemodynamic characteristics of in vivo brain tissue, in a non-contact fashion, and can be easily incorporated in an intra-operative environment. Within this methodology, relative total diffuse reflectance spectra (RTD(λ)) were acquired from targets using a hybrid spectroscopy imaging system. A spectral interpretation algorithm was subsequently applied to RTD(λ) to retrieve optical properties related to the compositional and structural characteristics of each target. Estimation errors of the proposed methodology were computationally evaluated using a Monte Carlo simulation model for photon migration under various conditions. It was discovered that this new methodology could handle moderate noise and achieve very high accuracy, but only if the refractive index of the target is known. The accuracy of the technique was also validated using a series of tissue phantom studies, and consistent and accurate estimates of μs'(λ)/μa(λ) were obtained from all the phantoms tested. Finally, a small-scale animal study was conducted to demonstrate the clinical utility of the reported method, wherein a forepaw stimulation model was utilized to induce transient hemodynamic responses in somatosensory cortices. With this approach, significant stimulation-related changes (p < 0.001) in cortical hemodynamic and structural characteristics were successfully measured.
Collapse
|
39
|
Keenan M, Tate TH, Kieu K, Black JF, Utzinger U, Barton JK. Design and characterization of a combined OCT and wide field imaging falloposcope for ovarian cancer detection. BIOMEDICAL OPTICS EXPRESS 2017; 8:124-136. [PMID: 28101406 PMCID: PMC5231286 DOI: 10.1364/boe.8.000124] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/02/2016] [Accepted: 12/05/2016] [Indexed: 05/02/2023]
Abstract
Early detection of ovarian cancer is only achieved in around 20% of women due to lack of effective screening. We propose a method for surveillance of high risk women based on a microendoscope introduced transvaginally to image the fallopian tubes and ovaries. This requires extreme miniaturization of the optics and catheter sheath. We describe the design of a falloposcope that combines optical coherence tomography (OCT) and wide field imaging into a sub-1 mm diameter package. We characterize the systems and show that they provide contrast on ex-vivo samples of ovary and fallopian tube. In addition, we show the mechanical performance of the endoscope in an anatomically correct model of the female reproductive tract.
Collapse
|
40
|
Salas M, Augustin M, Ginner L, Kumar A, Baumann B, Leitgeb R, Drexler W, Prager S, Hafner J, Schmidt-Erfurth U, Pircher M. Visualization of micro-capillaries using optical coherence tomography angiography with and without adaptive optics. BIOMEDICAL OPTICS EXPRESS 2017; 8:207-222. [PMID: 28101412 PMCID: PMC5231293 DOI: 10.1364/boe.8.000207] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Revised: 11/10/2016] [Accepted: 12/06/2016] [Indexed: 05/18/2023]
Abstract
The purpose of this work is to investigate the benefits of adaptive optics (AO) technology for optical coherence tomography angiography (OCTA). OCTA has shown great potential in non-invasively enhancing the contrast of vessels and small capillaries. Especially the capability of the technique to visualize capillaries with a lateral extension that is below the transverse resolution of the system opens unique opportunities in diagnosing retinal vascular diseases. However, there are some limitations of this technology such as shadowing and projection artifacts caused by overlying vasculature or the inability to determine the true extension of a vessel. Thus, the evaluation of the vascular structure and density based on OCTA alone can be misleading. In this paper we compare the performance of AO-OCT, AO-OCTA and OCTA for imaging retinal vasculature. The improved transverse resolution and the reduced depth of focus of AO-OCT and AO-OCTA greatly reduce shadowing artifacts allowing for a better differentiation and segmentation of different vasculature layers of the inner retina. The comparison is done on images recorded in healthy volunteers and in diabetic patients with distinct pathologies of the retinal microvasculature.
Collapse
|
41
|
Nandy S, Sanders M, Zhu Q. Classification and analysis of human ovarian tissue using full field optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2016; 7:5182-5187. [PMID: 28018734 PMCID: PMC5175561 DOI: 10.1364/boe.7.005182] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 11/09/2016] [Accepted: 11/09/2016] [Indexed: 05/26/2023]
Abstract
In this study, a full field optical coherence tomography (FFOCT) system was used to analyze and classify normal and malignant human ovarian tissue. 14 ovarian tissue samples (7 normal, 7 malignant) were imaged with the FFOCT system and five features were extracted by analyzing the normalized image histogram from 56 FFOCT images, based on the differences in the morphology of the normal and malignant tissue samples. A generalized linear model (GLM) classifier was trained using 36 images, and sensitivity of 95.3% and specificity of 91.1% was obtained. 20 images were used to test the model, and a sensitivity of 91.6% and specificity of 87.7% was obtained.
Collapse
|
42
|
Pollnau M, Hammer M, Dongre C, Hoekstra HJWM. Combined microfluidic-optical DNA analysis with single-base-pair sizing capability. BIOMEDICAL OPTICS EXPRESS 2016; 7:5201-5207. [PMID: 28018736 PMCID: PMC5175563 DOI: 10.1364/boe.7.005201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 11/11/2016] [Accepted: 11/11/2016] [Indexed: 06/06/2023]
Abstract
DNA sequencing by microchip capillary electrophoresis (CE) enables cheap, high-speed analysis of low reagent volumes. One of its potential applications is the identification of genomic deletions or insertions associated with genetic illnesses. Detecting single base-pair insertions or deletions from DNA fragments in the diagnostically relevant size range of 150-1000 base-pairs requires a variance of σ2 < 10-3. In a microfluidic chip post-processed by femtosecond-laser writing of an optical waveguide we CE-separated 12 blue-labeled and 23 red-labeled DNA fragments in size. Each set was excited by either of two lasers power-modulated at different frequencies, their fluorescence detected by a photomultiplier, and blue and red signals distinguished by Fourier analysis. We tested different calibration strategies. Choice of the fluorescent label as well as the applied fit function strongly influence the obtained variance, whereas fluctuations between two consecutive experiments are less detrimental in a laboratory environment. We demonstrate a variance of σ2 ≈4 × 10-4, lower than required for the detection of single base-pair insertion or deletion in an optofluidic chip.
Collapse
|
43
|
Pollonini L, Bortfeld H, Oghalai JS. PHOEBE: a method for real time mapping of optodes-scalp coupling in functional near-infrared spectroscopy. BIOMEDICAL OPTICS EXPRESS 2016; 7:5104-5119. [PMID: 28018728 PMCID: PMC5175555 DOI: 10.1364/boe.7.005104] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Revised: 10/22/2016] [Accepted: 10/31/2016] [Indexed: 05/06/2023]
Abstract
Recent functional near-infrared spectroscopy (fNIRS) instrumentation encompasses several dozen of optodes to enable reconstructing a hemodynamic image of the entire cerebral cortex. Despite its potential clinical applicability, widespread use of fNIRS with human subjects is currently limited by unresolved issues, namely the collection from the entirety of optical channels of signals with a signal-to-noise ratio (SNR) sufficient to carry out a reliable estimation of cortical hemodynamics, and the considerable amount of time that placing numerous optodes take with individuals for whom achieving good optical coupling to the scalp is difficult due to thick or dark hair. To address these issues, we developed a numerical method that: 1) at the channel level, computes an objective measure of the signal-to-noise ratio (SNR) related to its optical coupling to the scalp, akin to electrode conductivity used in electroencephalography (EEG), and 2) at the optode level, determines and displays the coupling status of all individual optodes in real time on a model of a human head. This approach aims to shorten the pre-acquisition preparation time by visually displaying which optodes require further adjustment for optimum scalp coupling, and to maximize the signal-to-noise ratio (SNR) of all optical channels contributing to the functional hemodynamic mapping. The methodology described in this paper has been implemented in a software tool named PHOEBE (placing headgear optodes efficiently before experimentation) that is freely available for use by the fNIRS community.
Collapse
|
44
|
Yu L, Wu Y, Dunn JF, Murari K. In-vivo monitoring of tissue oxygen saturation in deep brain structures using a single fiber optical system. BIOMEDICAL OPTICS EXPRESS 2016; 7:4685-4694. [PMID: 27896007 PMCID: PMC5119607 DOI: 10.1364/boe.7.004685] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 10/05/2016] [Accepted: 10/13/2016] [Indexed: 05/05/2023]
Abstract
We propose a single fiber optical system for monitoring tissue oxygen saturation (sO2) based on continuous-wave reflectance spectroscopy in the visible wavelengths. The system is designed for measurements in deep brain structures by stereotaxically implanting the 200 μm-core fiber probe into the tissue of interest. Monte Carlo (MC) simulations were used to estimate the measurement tissue volume between 0.02-0.03 mm3. Experiments in an optical phantom indicated the system had a root mean squared error (RMSE) of 4.21% compared with a commercial fluorescence-based tissue oxygen partial pressure measuring system. Finally, we used the system for continuously monitoring tissue sO2 from a highly-localized volume in anesthetized mice.
Collapse
|
45
|
Koo D, Park HC, Gehlbach PL, Song C. Development and preliminary results of bimanual smart micro-surgical system using a ball-lens coupled OCT distance sensor. BIOMEDICAL OPTICS EXPRESS 2016; 7:4816-4826. [PMID: 27896018 PMCID: PMC5119618 DOI: 10.1364/boe.7.004816] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 09/11/2016] [Accepted: 10/17/2016] [Indexed: 05/11/2023]
Abstract
Bimanual surgery enhances surgical effectiveness and is required to successfully accomplish complex microsurgical tasks. The essential advantage is the ability to simultaneously grasp tissue with one hand to provide counter traction or exposure, while dissecting with the other. Towards enhancing the precision and safety of bimanual microsurgery we present a bimanual SMART micro-surgical system for a preliminary ex-vivo study. To the best of our knowledge, this is the first demonstration of a handheld bimanual microsurgical system. The essential components include a ball-lens coupled common-path swept source optical coherence tomography sensor. This system effectively suppresses asynchronous hand tremor using two PZT motors in feedback control loop and efficiently assists ambidextrous tasks. It allows precise bimanual dissection of biological tissues with a reduction in operating time as compared to the same tasks performed with conventional one-handed approaches.
Collapse
|
46
|
Phan P, Highton D, Lai J, Smith M, Elwell C, Tachtsidis I. Multi-channel multi-distance broadband near-infrared spectroscopy system to measure the spatial response of cellular oxygen metabolism and tissue oxygenation. BIOMEDICAL OPTICS EXPRESS 2016; 7:4424-4440. [PMID: 27895985 PMCID: PMC5119585 DOI: 10.1364/boe.7.004424] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 09/22/2016] [Accepted: 09/26/2016] [Indexed: 05/22/2023]
Abstract
We present a multi-channel, multi-distance broadband near-infrared spectroscopy (NIRS) system with the capability of measuring changes in haemoglobin concentrations (Δ[HbO2], Δ[HHb]), oxidation state of cytochrome-c-oxidase (Δ[oxCCO]) and tissue oxygen saturation (TOI) in the adult human brain. The main components of the instrument are two customized spectrographs and two light sources. Each spectrograph is lens-based to improve light throughput, has a grating enhanced to optimise reflection in the near-infrared (NIR) spectral region and uses a front illuminated cooled CCD camera (-70° C) with a square chip dimension of 12.3 x 12.3 mm (512 x 512 pixels). Each light source uses a 50W halogen bulb with a gold plated mirror to increase the intensity of the NIR light. Each light source was connected to a custom-built bifurcated fibre bundle to create two source fibre bundles (3.2 mm diameter each). Each spectrograph received light input from another custom-built fibre bundle comprised of six individual bundles (one with 0.6 mm diameter and the other five with 1.5 mm diameter). All fibre bundles were fixed on a 3D printed optode holder (two light sources x two fibre bundles each = four probes; and two spectrographs x six fibre bundles each = 12 probes) that allowed 24 multi-distance channels across the forehead (six channels at 20 mm, three channels at 30 mm and 15 channels at 35 mm) and six TOI measurements. We demonstrated the use of the system in a cohort of nine healthy adult volunteers during prefrontal cortex functional activation using the Stroop task. We have observed functional responses identified as significant increase in Δ[HbO2], decrease in Δ[HHb] and increase in Δ[oxCCO] in five channels (out of 12), that overlay the left and right dorsolateral prefrontal cortices. There was no observable TOI functional response and we have shown small variations in TOI across different sites within the same subject and within the same site across subjects.
Collapse
|
47
|
Subramanian K, Gabay I, Ferhanoğlu O, Shadfan A, Pawlowski M, Wang Y, Tkaczyk T, Ben-Yakar A. Kagome fiber based ultrafast laser microsurgery probe delivering micro-Joule pulse energies. BIOMEDICAL OPTICS EXPRESS 2016; 7:4639-4653. [PMID: 27896003 PMCID: PMC5119603 DOI: 10.1364/boe.7.004639] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 10/12/2016] [Accepted: 10/13/2016] [Indexed: 05/22/2023]
Abstract
We present the development of a 5 mm, piezo-actuated, ultrafast laser scalpel for fast tissue microsurgery. Delivery of micro-Joules level energies to the tissue was made possible by a large, 31 μm, air-cored inhibited-coupling Kagome fiber. We overcome the fiber's low NA by using lenses made of high refractive index ZnS, which produced an optimal focusing condition with 0.23 NA objective. The optical design achieved a focused laser spot size of 4.5 μm diameter covering a 75 × 75 μm2 scan area in a miniaturized setting. The probe could deliver the maximum available laser power, achieving an average fluence of 7.8 J/cm2 on the tissue surface at 62% transmission efficiency. Such fluences could produce uninterrupted, 40 μm deep cuts at translational speeds of up to 5 mm/s along the tissue. We predicted that the best combination of speed and coverage exists at 8 mm/s for our conditions. The onset of nonlinear absorption in ZnS, however, limited the probe's energy delivery capabilities to 1.4 μJ for linear operation at 1.5 picosecond pulse-widths of our fiber laser. Alternatives like broadband CaF2 crystals should mitigate such nonlinear limiting behavior. Improved opto-mechanical design and appropriate material selection should allow substantially higher fluence delivery and propel such Kagome fiber-based scalpels towards clinical translation.
Collapse
|
48
|
Cosci A, Nogueira MS, Pratavieira S, Takahama A, Azevedo RDS, Kurachi C. Time-resolved fluorescence spectroscopy for clinical diagnosis of actinic cheilitis. BIOMEDICAL OPTICS EXPRESS 2016; 7:4210-4219. [PMID: 27867726 PMCID: PMC5102522 DOI: 10.1364/boe.7.004210] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 09/12/2016] [Accepted: 09/13/2016] [Indexed: 05/28/2023]
Abstract
Actinic cheilitis is a potentially malignant disorder of the lips. Its first cause is believed to be UV sun radiation. The lesion is highly heterogeneous, making the choice of area to be biopsied difficult. This study exploits the capabilities of time-resolved fluorescence spectroscopy for the identification of the most representative area to be biopsied. A preliminary study was performed on fourteen patients. A classification algorithm was used on data acquired on nine different biopsies. The algorithm discriminated between absent, mild, and moderate dysplasia with a sensitivity of 92.9%, 90.0%, and 80.0%, respectively. The false positive rate for healthy tissue (specificity) was 88.8%.
Collapse
|
49
|
Busch DR, Rusin CG, Miller-Hance W, Kibler K, Baker WB, Heinle JS, Fraser CD, Yodh AG, Licht DJ, Brady KM. Continuous cerebral hemodynamic measurement during deep hypothermic circulatory arrest. BIOMEDICAL OPTICS EXPRESS 2016; 7:3461-3470. [PMID: 27699112 PMCID: PMC5030024 DOI: 10.1364/boe.7.003461] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Revised: 08/05/2016] [Accepted: 08/08/2016] [Indexed: 05/03/2023]
Abstract
While survival of children with complex congenital heart defects has improved in recent years, roughly half suffer neurological deficits suspected to be related to cerebral ischemia. Here we report the first demonstration of optical diffuse correlation spectroscopy (DCS) for continuous and non-invasive monitoring of cerebral microvascular blood flow during complex human neonatal or cardiac surgery. Comparison between DCS and Doppler ultrasound flow measurements during deep hypothermia, circulatory arrest, and rewarming were in good agreement. Looking forward, DCS instrumentation, alone and with NIRS, could provide access to flow and metabolic biomarkers needed by clinicians to adjust neuroprotective therapy during surgery.
Collapse
|
50
|
Nishiyama M, Sonobe M, Watanabe K. Unconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor. BIOMEDICAL OPTICS EXPRESS 2016; 7:3675-3685. [PMID: 27699128 PMCID: PMC5030040 DOI: 10.1364/boe.7.003675] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 08/14/2016] [Accepted: 08/22/2016] [Indexed: 06/06/2023]
Abstract
In this paper, we present a pulse pressure waveform sensor that does not constrain a wearer's daily activity; the sensor uses hetero-core fiber optics. Hetero-core fiber sensors have been found to be sensitive to moderate bending. To detect minute pulse pressure changes from the radial artery at the wrist, we devised a fiber sensor arrangement using three-point bending supports. We analyzed and evaluated the measurement validity using wavelet transformation, which is well-suited for biological signal processing. It was confirmed that the detected pulse waveform had a fundamental mode frequency of around 1.25 Hz over the time-varying waveform. A band-pass filter with a range of frequencies from 0.85 to 1.7 Hz was used to pick up the fundamental mode. In addition, a high-pass filter with 0.85 Hz frequency eliminated arm motion artifacts; consequently, we achieved high signal-to-noise ratio. For unrestricted daily health management, it is desirable that pulse pressure monitoring can be achieved by simply placing a device on the hand without the sensor being noticed. Two types of arrangements were developed and demonstrated in which the pulse sensors were either embedded in a base, such as an armrest, or in a wearable device. A wearable device without cuff pressure using a sensitivity-enhanced fiber sensor was successfully achieved with a sensitivity of 0.07-0.3 dB with a noise floor lower than 0.01 dB for multiple subjects.
Collapse
|