26
|
Friebel M, Povel K, Cappius HJ, Helfmann J, Meinke M. Optical properties of dental restorative materials in the wavelength range 400 to 700 nm for the simulation of color perception. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:054029. [PMID: 19895131 DOI: 10.1117/1.3250292] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Aesthetic restorations require dental restorative materials to have optical properties very similar to those of the teeth. A method is developed to this end to determine the optical parameters absorption coefficient mu(a), scattering coefficient mu(s), anisotropy factor g, and effective scattering coefficient mu(s) (') of dental restorative materials. The method includes sample preparation and measurements of transmittance and reflectance in an integrating sphere spectrometer followed by inverse Monte Carlo simulations. Using this method the intrinsic optical parameters are determined for shade B2 of the light-activated composites TPH((R)) Spectrum, Esthet-X, and the Ormocer Definite in the wavelength range 400 to 700 nm. By using the determined parameters mu(a), mu(s), and g together with an appropriate phase function, the reflectance of samples with 1-mm layer thickness and shade B2 could be predicted with a very high degree of accuracy using a forward Monte Carlo simulation. The color perception was calculated from the simulated reflectance according to the CIELAB system. We initiate the compilation of a data pool of optical parameters that in the future will enable calculation models to be used as a basis for optimization of the optical approximation of the natural tooth, and the composition of new materials and their production process.
Collapse
|
27
|
Lü C, Chen X, Liu H. [Determination of alkylphenols and alkylphenol polyethoxylates in textiles by normal-phase high performance liquid chromatography and solid-phase extraction]. Se Pu 2009; 27:458-462. [PMID: 19938503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
Abstract
A method for the simultaneous determination of alkylphenols (AP) and alkylphenol polyethoxylates (APnEO) (n = 2-16) in textiles was developed by normal-phase high performance liquid chromatography (NP-HPLC). The residues of AP and APnEO in the samples were extracted with methanol by Soxhlet extraction. The pretreatment conditions such as extraction solvents, extraction methods and clean-up methods were optimized. The sample was purified by an HLB solid-phase extraction column and separated on an amino column (250 mm x 4.6 mm, 5 microm) with hexane-isopropanol (90:10, v/v) and isopropanol-water (90:10, v/v) as mobile phases at a flow rate of 1.0 mL/min and determined by a fluorescence detector. AP and each APnEO oligomer were separated successfully within a reasonable time with gradient elution, which are difficult to be separated by using conventional reversed-phase high performance liquid chromatography (RP-HPLC). The detection limit was 1.0 mg/kg for each analyte. The recoveries ranged from 90.4% to 104.1% with the relative standard deviations (RSDs) ranged from 0.64% to 4.21%. This method is suitable for the determination of alkylphenols and alkylphenol polyethoxylates in textiles.
Collapse
|
28
|
Xing JM, Li FF. Separation and purification of Aloe polysaccharides by a combination of membrane ultrafiltration and aqueous two-phase extraction. Appl Biochem Biotechnol 2009; 158:11-9. [PMID: 19415529 DOI: 10.1007/s12010-009-8641-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2008] [Accepted: 04/06/2009] [Indexed: 11/27/2022]
Abstract
A two-step process was developed for the purification of polysaccharides from the pulp of Aloe varavia using aqueous two-phase system (ATPS) extraction and a novel copolymer ultrafiltration membrane. The first step was ATPS under optimal separations conditions using a total composition of 18% PEG2000, 25% ammonium sulfate, pH 3.0, and 0.3 M NaCl. To form the copolymer membrane, poly(acrylonitrile-acrylamide-styrene) was prepared by solution polycondensation using azoisobutyronitrile as initiator. Then, membranes were formed from the dissolved copolymer by the phase inversion method. Copolymer structure was investigated by infrared spectrum and thermogravimetric analysis (TGA). The copolymer membrane surface and cross section were observed by scanning electron microscopy. The water flux of this membrane was 26.33 mL/(cm(2) h), and retention was 96% for bovine serum albumin and 34% for dextran T40000. The separation and purification of aloe polysaccharide were carried using this copolymer membrane following ATPS. The TGA of aloe polysaccharide demonstrated a high purity of the polysaccharide. By gas chromatographic analysis, it was shown that mannose is the main monosaccharide in the aloe polysaccharide, and only a few glucose residues are present.
Collapse
|
29
|
Comolli N, Neuhuber B, Fischer I, Lowman A. In vitro analysis of PNIPAAm-PEG, a novel, injectable scaffold for spinal cord repair. Acta Biomater 2009; 5:1046-55. [PMID: 19054721 PMCID: PMC2844850 DOI: 10.1016/j.actbio.2008.10.008] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2008] [Revised: 09/30/2008] [Accepted: 10/08/2008] [Indexed: 11/20/2022]
Abstract
Nervous tissue engineering in combination with other therapeutic strategies is an emerging trend for the treatment of different CNS disorders and injuries. We propose to use poly(N-isopropylacrylamide)-co-poly(ethylene glycol) (PNIPAAm-PEG) as a minimally invasive, injectable scaffold platform for the repair of spinal cord injury (SCI). The scaffold allows cell attachment, and provides mechanical support and a sustained release of neurotrophins. In order to use PNIPAAm-PEG as an injectable scaffold for treatment of SCI, it must maintain its mass and volume over time in physiological conditions. To provide mechanical support at the injury site, it is also critical that the engineered scaffold matches the compressive modulus of the native neuronal tissue. This study focused on studying the ability of the scaffold to release bioactive neurotrophins and matching the material properties to those of the native neuronal tissue. We found that the release of both BDNF and NT-3 was sustained for up to 4 weeks, with a minimal burst exhibited for both neurotrophins. The bioactivity of the released NT-3 and BDNF was confirmed after 4 weeks. In addition, our results show that the PNIPAAm-PEG scaffold can be designed to match the desired mechanical properties of the native neuronal tissue, with a compressive modulus in the 3-5 kPa range. The scaffold was also compatible with bone marrow stromal cells, allowing their survival and attachment for up to 31 days. These results indicate that PNIPAAm-PEG is a promising multifunctional scaffold for the treatment of SCI.
Collapse
|
30
|
Garmo OA, Davison W, Zhang H. Interactions of trace metals with hydrogels and filter membranes used in DET and DGT techniques. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2008; 42:5682-5687. [PMID: 18754493 DOI: 10.1021/es800143r] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Equilibrium partitioning of trace metals between bulk solution and hydrogels/filter was studied. Under some conditions, trace metal concentrations were higher in the hydrogels or filter membranes compared to bulk solution (enrichment). In synthetic soft water, enrichment of cationic trace metals in polyacrylamide hydrogels decreased with increasing trace metal concentration. Enrichment was little affected by Ca and Mg in the concentration range typically encountered in natural freshwaters, indicating high affinity but low capacity binding of trace metals to solid structure in polyacrylamide gels. The apparent binding strength decreased in the sequence: Cu > Pb > Ni approximately to Cd approximately to Co and a low concentration of cationic Cu eliminated enrichment of weakly binding trace metal cations. The polyacrylamide gels also had an affinity for fulvic acid and/or its trace metal complexes. Enrichment of cationic Cd in agarose gel and hydrophilic polyethersulfone filter was independent of concentration (10 nM to 5 microM) but decreased with increasing Ca/ Mg concentration and ionic strength, suggesting that it is mainly due to electrostatic interactions. However, Cu and Pb were enriched even after equilibration in seawater, indicating that these metals additionally bind to sites within the agarose gel and filter. Compared to the polyacrylamide gels, agarose gel had a lower affinity for metal-fulvic complexes. Potential biases in measurements made with the diffusive equilibration in thin-films (DET) technique, identified by this work, are discussed.
Collapse
|
31
|
Krauth DM, Bouldin JL, Green VS, Wren PS, Baker WH. Evaluation of a polyacrylamide soil additive to reduce agricultural-associated contamination. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2008; 81:116-123. [PMID: 18463774 DOI: 10.1007/s00128-008-9448-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2008] [Accepted: 04/22/2008] [Indexed: 05/26/2023]
Abstract
Polyacrylamide is an effective water treatment product used to reduce suspended sediment and associated contaminants. An anionic polyacrylamide-containing product was tested for sediment and associated contaminant reduction and potential toxicity in agricultural irrigation and rainfall runoff. The product effectively reduced turbidity, total suspended solids, and phosphate concentrations in the field when compared to the untreated runoff waters. Acute survival of Ceriodaphnia dubia and Pimephales promelas was not decreased compared to laboratory controls. No significant increases in toxicity were measured in 10-d sediment toxicity tests with Chironomus dilutus. Product applications were effective in controlling sediment and nutrient contamination without increasing measured toxicity.
Collapse
|
32
|
Snively CM, Kim YS, Chase DB, Rabolt JF. Rapid detection of low concentrations of aqueous species in the presence of spectral overlap using planar array infrared spectroscopy. APPLIED SPECTROSCOPY 2008; 62:337-339. [PMID: 18339244 DOI: 10.1366/000370208783759777] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
33
|
Leitlinie zur hygienischen Beurteilung von organischen Beschichtungen im Kontakt mit Trinkwasser (Beschichtungsleitlinie). Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2007; 50:1152-76. [PMID: 17828478 DOI: 10.1007/s00103-007-0316-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
34
|
Rellán S, Gago-Martínez A. Improved conditions for the application of solid phase microextraction prior to HPLC-FLD analysis of anatoxin-a. J Sep Sci 2007; 30:2522-8. [PMID: 17763520 DOI: 10.1002/jssc.200700103] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Solid phase microextraction coupled with high performance liquid chromatography with fluorescence detection has been optimized and evaluated for a simple, rapid, and selective analysis of anatoxin-a. Four kinds of fiber (100 microm polydimethylsiloxane, 60 microm polydimethylsiloxane/divinylbenzene, 50 microm Carbowax/templated resin-100, and 85 microm polyacrylate) were evaluated for an efficient extraction of the toxin. Parameters relating to the desorption step, such as desorption mode, solvent composition, time for both static and dynamic desorption, as well as carryover, have been studied and optimized. The derivatization process was investigated using NBD-F as derivatizing reagent. Anatoxin-a derivative was formed when the anatoxin-a-loaded fiber was inserted in a vial containing 5 microL of NBD-F. Variables affecting extraction such us ionic strength, temperature, and time have been also optimized. The results obtained showed linearity in the range of 10-2000 ng and a limit of detection of 0.29 ng/mL in river water. The presented method has been applied to different environmental samples.
Collapse
|
35
|
Lu L, Gao BY, Yue QY, Cao BC. [Flocculation of wastewater produced in polymer flooding]. HUAN JING KE XUE= HUANJING KEXUE 2007; 28:761-5. [PMID: 17639933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The particle size distribution, flocculation index, Zeta potential and oil content in water were tested during flocculation of wastewater produced in polymer flooding of oil field. CHP-03, a mixture of a modified pluronic demulsifer and a weak-cationic flocculant, was used to improve the efficiency of oil droplet collision. The effects of polyacrylamide, temperature, and mixing speed on flocculation dynamics are discussed. Polyacrylamide affects the oil-water separation by obstructing the aggregation of small oil droplets, but electrostatic repulsion is not a major factor in preventing flocculation. The local temperature has a limited effect on flocculation. Fast mixing favors the growth of flocs, while slow mixing is suitable for the coalescence of oil droplets. Addition of 250 mg/L CHP-03 can enhance the oil-water separation and remove 92% of the oil content.
Collapse
|
36
|
Yuan J, You Y, Lu X, Muzik O, Oupicky D, Peng F. Synthesis of Poly[APMA]-DOTA-64Cu conjugates for interventional radionuclide therapy of prostate cancer: assessment of intratumoral retention by micro-positron emission tomography. Mol Imaging 2007; 6:10-7. [PMID: 17311761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023] Open
Abstract
To develop new radiopharmaceuticals for interventional radionuclide therapy of locally recurrent prostate cancer, poly[N-(3-aminopropyl)methacrylamide] [poly(APMA)] polymers were synthesized by free radical precipitation polymerization in acetone-dimethylsulfoxide using N,N'-azobis(isobutyronitrile) as the initiator. The polymers were characterized with nuclear magnetic resonance, size exclusion chromatography, and dynamic light scattering (M(n) = 2.40 x 10(4), M(w)/M(n) = 1.87). Subsequently, poly[APMA] was coupled with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride as an activator, followed by conjugation with (64)Cu radionuclide. Prolonged retention of poly[APMA]-DOTA-(64)Cu conjugates within the tumor tissues was demonstrated by micro-positron emission tomography at 24 hours following intra-tumoral injection of the conjugates to human prostate xenografts in mice. The data suggest that the poly[APMA]-DOTA-(64)Cu conjugates might be useful for interventional radionuclide therapy of locally recurrent prostate cancer in humans.
Collapse
|
37
|
Lewis AL, Adams C, Busby W, Jones SA, Wolfenden LC, Leppard SW, Palmer RR, Small S. Comparative in vitro evaluation of microspherical embolisation agents. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2006; 17:1193-204. [PMID: 17143749 DOI: 10.1007/s10856-006-0592-x] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2005] [Accepted: 01/04/2006] [Indexed: 05/12/2023]
Abstract
This study describes the comparative performance of four commercially available microspherical embolisation products: Embosphere, Embogold, Contour SE and Bead Block. A series of in vitro evaluations were designed to assess the mechanical and biological characteristics of these biomaterials. Size distribution analysis revealed sieving techniques used to fractionate the embolics produced similar size distributions. The forces required to compress Embosphere, Embogold and Bead Block were in the range 21-27.5 kPa. Contour SE was significantly more compressible at approximately 5 kPa. However, recoverability of Contour SE required several minutes in contrast to the other products, a phenomenon attributed to its macroporous structure. When time taken to reach and remain in suspension was studied, results showed that the products quickly reached equilibrium with contrast agent. Bead Block was maintained in suspension for twice as long as the other products. Catheter deliverability was assessed and found to be dependent upon both microsphere and catheter, the best combination being Bead Block delivered via the Progreat catheter. Both the blood contacting SEM and plasma coagulation time showed none of the products were pro-thrombic or pro-coagulatory, each producing comparable results. Small differences in physical properties such as compressibility, could play an important role in delivery and effectiveness of vessel blockage. Currently all products are used routinely in clinical practice.
Collapse
|
38
|
Genç L, Demirel M, Yazan Y. Preparation of prolonged release clarithromycin microparticles for oral use and theirin vitro evaluation. Arch Pharm Res 2006; 29:921-7. [PMID: 17121189 DOI: 10.1007/bf02973915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Prolonged release microparticles of clarithromycin (CL) were prepared using Eudragit RL 100 and RS 100 by spray-drying and casting-drying techniques. For the characterization of those microparticles, preparation yield, particle size distribution, X-ray diffraction, thermal behavior, active agent content and in vitro dissolution from the microparticles were performed. HPLC was used for the assay of clarithromycin and the assay method was validated. All the formulations obtained showed prolonged release when compared to pure clarithromycin. Microparticles prepared by spray-drying method had a slower release compared to those of casting-drying method. Spray-drying method seems to be a more suitable method to prepare microparticles for prolongation in release.
Collapse
|
39
|
Bush MA, Bush PJ, Miller RG. Detection and classification of composite resins in incinerated teeth for forensic purposes. J Forensic Sci 2006; 51:636-42. [PMID: 16696713 DOI: 10.1111/j.1556-4029.2006.00121.x] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The great demand for esthetic restorations has resulted in placement of large numbers of composite resin fillings. The popularity of these materials is reflected in the quantity and variety of resin brands currently on the market. The ability to distinguish resin brands can aid in positive identification of burn victims, assuming that appropriate dental records exist. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) was used to characterize the structure and composition of 10 modern resins. The structure of each resin was unique to manufacturer, and elemental analysis allowed separation into distinct groups. These 10 resins were also placed in extracted teeth and incinerated at 900 degrees C for 30 min, simulating near cremation conditions. The resins were identifiable by SEM/EDS after incineration, and the elemental composition remained almost unchanged. The data produced are immediately useful for resin identification in forensics, and comparative analysis can be readily performed using standard equipment. This work represents the initial stage of database generation.
Collapse
|
40
|
Bae PH, Hwang YJ, Jo HJ, Kim HJ, Lee Y, Park YK, Kim JG, Jung J. Size removal on polyester fabrics by plasma source ion implantation device. CHEMOSPHERE 2006; 63:1041-7. [PMID: 16324734 DOI: 10.1016/j.chemosphere.2005.09.055] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2005] [Revised: 09/01/2005] [Accepted: 09/07/2005] [Indexed: 05/05/2023]
Abstract
Plasma treatment was evaluated as an alternative clean desizing technology in this work. As indicated by weight loss, O2 plasma treatment efficiently removed sizing agents such as polyvintyl alcohol (PVA), polyacrylic acid esters and their mixture (MIX) on polyethylene terephthalate (PET) fabrics. SEM pictures of the plasma treated samples directly proved the disappearance of the sizing agents. XPS analysis showed apparent changes in chemical composition and functional groups of the PET surface after O2 plasma treatment. Carbon content decreased due to the removal of sizing agents while oxygen content increased. O2 plasma treatment also increased hydrophilic functional groups of sizing agents, which is confirmed by C1s and O1s deconvolution analyses. After O2 plasma treatment, the PET fabric was subjected to conventional desizing process at different temperatures. Except for the PET fabric sized with PVA, plasma-treated fabrics showed more efficient desizing results when compared with untreated fabrics. Furthermore, the desizing effluent from the treated fabric gave lower TOC, COD and BOD values.
Collapse
|
41
|
Wang J, Chen Z, Mauk M, Hong KS, Li M, Yang S, Bau HH. Self-actuated, thermo-responsive hydrogel valves for lab on a chip. Biomed Microdevices 2006; 7:313-22. [PMID: 16404509 DOI: 10.1007/s10544-005-6073-z] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
An easy to fabricate, thermally-actuated, self-regulated hydrogel valve for flow control in pneumatically driven, microfluidic systems is described. This microvalve takes advantage of the properties of the hydrogel, poly(N-isopropylacrylamide), as well as the aqueous fluid itself to realize flow control. The valve was designed for use in a diagnostic system fabricated with polycarbonate and aimed at the detection of pathogens in oral fluids at the location of the sample collection. The paper describes the construction and characterization of the hydrogel valves and their application for flow control, sample and reagent metering, sample distribution into multiple analysis paths, and the sealing of a polymerase chain reaction (PCR) reactor to suppress bubble formation. The hydrogel-based flow control is electronically addressable, does not require any moving parts, introduces minimal dead volume, is leakage and contaminant free, and is biocompatible.
Collapse
|
42
|
Mc Nally L, O'Sullivan DJ, Jagger DC. An in vitro investigation of the effect of the addition of untreated and surface treated silica on the transverse and impact strength of poly(methyl methacrylate) acrylic resin. Biomed Mater Eng 2006; 16:93-100. [PMID: 16477118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Silica is a commonly used filler in dental materials and as a reinforcing agent in industry. The aim of this study was to further investigate the effect of the addition of untreated and a novel surface treated silica on the transverse bend and impact strength of acrylic resin denture base material. It was hypothesized that the silica/resin composite materials would have an improved flexural and impact strength than the conventional heat-cured acrylic resin. Three types of untreated and two of treated silica powder were used in this study. The range of percentages used were 1%, 0.5%, 0.2%, 0.1%. The treated particles were coated with hexamethyldisilazane or dimethyldichloridesilazane. Conventional heat cured acrylic resin was used as a control. The modulus of rupture for all groups of acrylic resin containing silica was significantly lower than for the control. The modulus of elasticity was not significantly greater than the control group. For the impact strength statistical analysis revealed a significant difference between the groups. There was a nonsignificant increase in the impact strength for specimens compared to the control. In conclusion the addition of silica to poly(methyl methacrylate) denture base materials did not produce a significant improvement in the transverse bend or impact strength compared to conventional heat-cured acrylic resin. The incorporation of untreated and surface treated silica cannot be recommended as a method of reinforcement.
Collapse
|
43
|
Xi TF, Fan CX, Feng XM, Wan ZY, Wang CR, Chou LL. Cytotoxicity and alteredc-myc gene expression by medical polyacrylamide hydrogel. J Biomed Mater Res A 2006; 78:283-90. [PMID: 16637045 DOI: 10.1002/jbm.a.30619] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Medical Polyacrylamide Hydrogel (PAMG)has been used in plastic and aesthetic surgery for years. However, its safety is still in doubt in many countries. In the current research, first an approach, using high performance liquid chromatography (HPLC), to determine the amount of residual acrylamide monomer (AM) in the PAMG was presented. Then the cytotoxicity of PAMG was investigated using cell counting and methyl thiazolyl tetrazolium (MTT) assay. To explore the mechanism of this toxicity, normal human fibroblasts cultured in medium extracts were analyzed. Membrane changes and other related parameters were investigated using flow cytometry (FCM). Real time fluorescent polymerase chain reaction (real time PCR) was also introduced to determine the biological response of the fibroblasts. During this process, three representative genes (p53, beta-actin, and c-myc, which are tumor suppressor genes, housekeeping genes, and proto-oncogenes respectively) were selected for examination. Results indicated that a method based on HPLC is practical and simple for determining AM in PAMG. The detection limits can reach the desired ppb level, and so it can fully meet the requirements of the studies of PAMG. Polyacylamide Hydrogel inhibits the growth of human fibroblasts and may cause the apoptosis of human fibroblasts. Moreover, it can alter physical parameters such as the size and the granularity of these cells. Furthermore, these three genes have a relatively typical amplification plot and highly related, wide-range standard curves, and so this reaction system is definitely suitable for the semiquantification of these genes. PAMG induces the increase of the message ribonucleic acid (mRNA) expression of c-myc, while the p53 and beta-actin remain even. This change is not related to the concentration of AM in the gel and may be incited by other components in the extract of PMAG.
Collapse
|
44
|
Ye P, Xu ZK, Che AF, Wu J, Seta P. Chitosan-tethered poly(acrylonitrile--maleic acid) hollow fiber membrane for lipase immobilization. Biomaterials 2005; 26:6394-403. [PMID: 15919112 DOI: 10.1016/j.biomaterials.2005.04.019] [Citation(s) in RCA: 122] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2005] [Accepted: 04/07/2005] [Indexed: 02/08/2023]
Abstract
A protocol was used to prepare a dual-layer biomimetic membrane as support for enzyme immobilization by tethering chitosan on the surface of poly(acrylonitrile-co-maleic acid) (PANCMA) ultrafiltration hollow fiber membrane in the presence of 1-ethyl-3-(dimethylaminopropyl) carbodiimide hydrochloride (EDC)/N-hydroxylsuccin-imide (NHS). The chemical change of the chitosan-modified PANCMA membrane surface was confirmed with Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Lipase from Candida rugosa was immobilized on this dual-layer biomimetic membrane using glutaraldehyde (GA), and on the nascent PANCMA membrane using EDC/NHS as coupling agent. The properties of the immobilized enzymes were assayed and compared with those of the free one. It was found that both the activity retention of the immobilized lipase and the amount of bound protein on the dual-layer biomimetic membrane (44.5% and 66.5 mg/m2) were higher than those on the nascent PANCMA membrane (33.9% and 53.7 mg/m2). The kinetic parameters of the free and immobilized lipases, Km and Vmax, were also assayed. The Km values were similar for the immobilized lipases, while the Vmax value of the immobilized lipase on the dual-layer biomimetic membrane was higher than that on the nascent PANCMA membrane. Results indicated that the pH and thermal stabilities of lipase increased upon immobilization. The residual activity of the immobilized lipase after 10 uses was 53% on the dual-layer biomimetic membrane and 62% on the nascent PANCMA membrane.
Collapse
|
45
|
Atai M, Watts DC, Atai Z. Shrinkage strain-rates of dental resin-monomer and composite systems. Biomaterials 2005; 26:5015-20. [PMID: 15769537 DOI: 10.1016/j.biomaterials.2005.01.022] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2004] [Accepted: 01/07/2005] [Indexed: 11/30/2022]
Abstract
The purpose of this study was to investigate the shrinkage strain rate of different monomers, which are commonly used in dental composites and the effect of monomer functionality and molecular mass on the rate. Bis-GMA, TEGDMA, UDMA, MMA, HEMA, HPMA and different ratios of Bis-GMA/TEGDMA were mixed with Camphorquinone and Dimethyl aminoethyle methacrylate as initiator system. The shrinkage strain of the samples photopolymerised at Ca. 550 mW/cm2 and 23 degrees C was measured using the bonded-disk technique of Watts and Cash (Meas. Sci. Technol. 2 (1991) 788-794), and initial shrinkage-strain rates were obtained by numerical differentiation. Shrinkage-strain rates rose rapidly to a maximum, and then fell rapidly upon vitrification. Strain and initial strain rate were dependent upon monomer functionality, molecular mass and viscosity. Strain rates were correlated with Bis-GMA in Bis-GMA/TEGDMA mixtures up to 75-80 w/w%, due to the higher molecular mass of Bis-GMA affecting termination reactions, and then decreased due to its higher viscosity affecting propagation reactions. Monofunctional monomers exhibited lower rates. UDMA, a difunctional monomer of medium viscosity, showed the highest shrinkage strain rate (P < 0.05). Shrinkage strain rate, related to polymerization rate, is an important factor affecting the biomechanics and marginal integrity of composites cured in dental cavities. This study shows how this is related to monomer molecular structure and viscosity. The results are significant for the production, optimization and clinical application of dental composite restoratives.
Collapse
|
46
|
Yasuda K, Ping Gong J, Katsuyama Y, Nakayama A, Tanabe Y, Kondo E, Ueno M, Osada Y. Biomechanical properties of high-toughness double network hydrogels. Biomaterials 2005; 26:4468-75. [PMID: 15701376 DOI: 10.1016/j.biomaterials.2004.11.021] [Citation(s) in RCA: 259] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2004] [Accepted: 11/16/2004] [Indexed: 11/19/2022]
Abstract
This study evaluated the wear property of four novel double-network (DN) hydrogels, which was composed of two kinds of hydrophilic polymers, using pin-on-flat wear testing. The gels involve PAMPS-PAAm gel which consists of poly(2-acrylamide-2-metyl-propane sulfonic acid) and polyacrylamide, PAMPS-PDAAAm gel which consists of poly(2-acrylamide-2-metyl-propane sulfonic acid) and poly(N,N'-dimetyl acrylamide), Cellulose/PDMAAm gel which consists of bacterial Cellulose and poly dimetyl-acrylamide, and Cellulose-Gelatin gel which consists of bacterial Cellulose and Gelatin. Ultra-high molecular weight polyethylene (UHMWPE) was used as a control of a clinically available material. Using a reciprocating apparatus, 10(6) cycles of friction between a flat specimen and ceramic pin were repeated in water under a contact pressure of 0.1 MPa. To determine the depth and the roughness of the concave lesion created by wear, a confocal laser microscope was used. As a result, the maximum wear depth of the PAMPS-PDMAAm gel (3.20 microm) was minimal in the five materials, while there was no significant difference compared to UHMWPE. There were significant differences between UHMWPE and one of the other three gels. The PAMPS-PAAm gel (9.50 microm), the Cellulose-PDMAAm gel (7.80 microm), and the Cellulose-Gelatin gel (1302.40 microm). This study demonstrated that the PAMPS-PDMAAm DN gel has an amazing wear property as a hydrogel that is comparable to the UHMWPE. In addition, the PAMPS-PAAm and Cellulose-PDMAAm DN gels are also resistant to wear to greater degrees than conventionally reported hydrogels. On the other hand, this study showed that the Cellulose-Gelatin DN gel was not resistant to wear.
Collapse
|
47
|
Li Z, Jones Y, Hossenlopp J, Cernosek R, Josse F. Analysis of Liquid-Phase Chemical Detection Using Guided Shear Horizontal-Surface Acoustic Wave Sensors. Anal Chem 2005; 77:4595-603. [PMID: 16013878 DOI: 10.1021/ac0504621] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Direct chemical sensing in liquid environments using polymer-guided shear horizontal surface acoustic wave sensor platforms on 36 degrees rotated Y-cut LiTaO3 is investigated. Design considerations for optimizing these devices for liquid-phase detection are systematically explored. Two different sensor geometries are experimentally and theoretically analyzed. Dual delay line devices are used with a reference line coated with poly (methyl methacrylate) (PMMA) and a sensing line coated with a chemically sensitive polymer, which acts as both a guiding layer and a sensing layer or with a PMMA waveguide and a chemically sensitive polymer. Results show the three-layer model provides higher sensitivity than the four-layer model. Contributions from mass loading and coating viscoelasticity changes to the sensor response are evaluated, taking into account the added mass, swelling, and plasticization. Chemically sensitive polymers are investigated in the detection of low concentrations (1-60 ppm) of toluene, ethylbenzene, and xylenes in water. A low-ppb level detection limit is estimated from the present experimental measurements. Sensor properties are investigated by varying the sensor geometries, coating thickness combinations, coating properties, and curing temperature for operation in liquid environments. Partition coefficients for polymer-aqueous analyte pairs are used to explain the observed trend in sensitivity for the polymers PMMA, poly(isobutylene), poly(epichlorohydrin), and poly(ethyl acrylate) used in this work.
Collapse
|
48
|
Mateović-Rojnik T, Frlan R, Bogataj M, Bukovec P, Mrhar A. Effect of preparation temperature in solvent evaporation process on Eudragit RS microsphere properties. Chem Pharm Bull (Tokyo) 2005; 53:143-6. [PMID: 15635253 DOI: 10.1248/cpb.53.143] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Eudragit RS 100 microspheres containing ketoprofen as a model drug were prepared by the solvent evaporation method using an acetone/liquid paraffin solvent system. The influence of various preparation temperatures: 10, 25, 35, and 40 degrees C, on particle size and morphology, drug content and release kinetics, and drug crystal state was evaluated. With increasing temperature, microsphere average size was found to increase and particle size distribution to widen significantly. At 10 degrees C particles of irregular shape are formed, whereas higher temperatures gradually improve the sphericity of microspheres. As can be seen from SEM photographs, particle surface roughness decreases as preparation temperature increases. It was found that temperature had no effect either on ketoprofen microencapsulation efficiency or on its crystal state, but it does influence emulsion-stabilizer incorporation. Ketoprofen forms solid solution in Eudragit matrix and maintains amorphous state for significant period of time. Drug release rates from microspheres correlated with microspheres' surface roughness and to a lesser extent with particle size.
Collapse
|
49
|
Kalasinsky KS, Kalasinsky VF. Infrared and Raman microspectroscopy of foreign materials in tissue specimens. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2005; 61:1707-1713. [PMID: 15820906 DOI: 10.1016/j.saa.2004.12.048] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2004] [Accepted: 12/15/2004] [Indexed: 05/24/2023]
Abstract
Infrared and Raman spectra of materials found in tissue specimens submitted for histopathologic diagnosis have been recorded. These foreign materials range in size from approximately 5 to 50 microm, and the vibrational spectra have been used to identify them. Examples include cholesterol and polytetrafluoroethylene (PTFE) in an implant case, polyethylene terephthalate (PET) and polyacrylonitrile (PAN) in a pilonidal cyst, and carbenicillin in a skin biopsy. In some instances, either the infrared or Raman spectra were sufficient to make a definitive identification, while in other cases both were necessary. Because some of the samples fluoresced with visible excitation at 532 nm, FT-Raman spectra with 1064-nm excitation were also recorded. The flexibility of sampling for vibrational microspectroscopy and the value of the recorded data in assisting pathologists render medical diagnoses in the examples cited and other cases are discussed.
Collapse
|
50
|
Yin W, Yang H, Cheng R. Glass transition of the two distinct single-chain particles of poly(N-isopropylacrylamide). THE EUROPEAN PHYSICAL JOURNAL. E, SOFT MATTER 2005; 17:1-5. [PMID: 15827689 DOI: 10.1140/epje/i2004-10113-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2004] [Accepted: 03/05/2005] [Indexed: 05/24/2023]
Abstract
Two distinct single-chain particles of poly(N-isopropylacrylamide) (PNIPAM) in the state of loose coil and compact globule, have been prepared successfully below and above the lower critical solution temperature (LCST) in extreme dilute aqueous solution by the freeze-drying method, respectively. During the preparation of the compact globular single-chain sample, the surfactant of sodium n-dodecyl sulfate (SDS) was added into the system to prevent aggregation of globular single chains formed at a temperature above the LCST. After all the coil has been transformed into the compact globular particle, the SDS molecules were removed by dialysis. The glass transition temperature (T(g)) of the two single-chain samples has been measured by differential scanning calorimetery (DSC) in comparison with that of bulk polymer. It was found that the T(g) of the single-chain sample in compact-globule state was very near to that of the bulk polymer, whereas the T(g) of the single-chain sample in loose-coil state was approximately 6 K lower than that of the bulk polymer. After treating the sample with repeated DSC cycles, the T(g) of the single-chain sample in loose-coil state rose up successively near to that of the bulk polymer. These results have been explained in terms of the effect of entanglement on the mobility of the polymer segments in the two distinct single-chain samples.
Collapse
|