51
|
Kontorshchikova KN, Kazarina LN, Gulyan UG, Pursanova AE, Zakharova AR, Kontorshchikov MM, Gushchina OO. Monitoring of biochemical parameters of the oral fluid in patients with recancerous of the oral mucosa. Klin Lab Diagn 2022; 67:19-23. [PMID: 35077065 DOI: 10.51620/0869-2084-2022-67-1-19-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Orthopedic treatment is of particular difficulty in the complex therapy and rehabilitation of patients with precancerous diseases of the oral mucosa. In this regard, in patients with chronic inflammatory and destructive lesions of the oral mucosa, it is necessary to control changes in the oral cavity, taking into account clinical and laboratory data. Oral fluid is most often used as a diagnostic material in dental research, the composition and properties of which reflect functional changes in the body. However, the studies that substantiate rational orthopedic treatment in such patients are extremely insufficient: there are no data on the effect of orthopedic structures on the primary metabolism in the oral cavity in patients with precancerous diseases. In this regard, the purpose of this work was to study the biochemical parameters of the oral fluid in patients using orthopedic structures to identify the prognostic factors of precancerous conditions. In the oral fluid, the levels of total protein, total cholesterol, triglycerides, and lactate were determined. Free radical oxidation was assessed by the intensity of induced biochemiluminescence and by the levels of lipid peroxidation products. In the oral fluid of patients with mucosal precancer compared with patients in the control group, a significantly higher intensity of free radical oxidation was revealed with a corresponding decrease in antioxidant activity. The level of the end products of lipid peroxidation - Schiff's bases - was statistically significantly increased. Among the metabolites of the oral fluid, there was a decrease in protein levels and an increase in cholesterol and lactate levels. At the same time, a positive correlation was established between the indicators of free radical oxidation and lactate, free radical oxidation and cholesterol, but negative with the levels of protein and triglycerides. Regarding the antioxidant system, there was a negative correlation between the tg (-2α) value and the lactate level and positive with the triglyceride level, as well as a positive correlation between the Z parameter and the total protein level. The obtained changes in the biochemical parameters of the oral fluid can be used to confirm the diagnosis of precancer of the oral mucosa in patients with orthopedic structures.
Collapse
|
52
|
Almeida E, Soares S, Gonçalves J, Rosado T, Fernández N, Rodilla JM, Passarinha LA, Barroso M, Gallardo E. Stability of Cocaine, Opiates, and Metabolites in Dried Saliva Spots. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27030641. [PMID: 35163906 PMCID: PMC8839019 DOI: 10.3390/molecules27030641] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/14/2022] [Accepted: 01/17/2022] [Indexed: 12/20/2022]
Abstract
Drug abuse still represents a global problem, and it is associated with an increased risk of diseases, injuries, and deaths. Cocaine (COC) and opiates are the most abused drugs and account for a significant number of fatalities. Therefore, it is important to develop methods capable of effectively identifying and quantifying these substances. The present study aims to evaluate the long-term stability of COC, ecgonine methylester (EME), benzoylecgonine (BEG), cocaethylene (COET), norcocaine (NCOC), morphine (MOR), codeine (COD) and 6-monoacetylmorphine (6-MAM) in oral fluid samples. The analytes of interest were isolated from the matrix (50 µL) using the dried saliva spots (DSS) sampling approach and were subsequently analyzed by gas chromatography coupled with tandem mass spectrometry (GC–MS/MS). The parameters that could influence the stability of the target compounds were studied, and these were storage temperature, light, use of preservatives (and respective concentrations), and time. The effects of each parameter were evaluated using the design of experiments (DOE) approach. The stability of the target analytes was improved when the DSS were stored at room temperature, in the presence of light and using 1% sodium fluoride. The best conditions were then adopted for the DSS storage and long-term stability was assessed. COD was only stable for 1 day, EME was stable for 3 days, COC, COET, NCOC and 6-MAM were stable for 7 days, MOR for 14 days and BEG remained stable throughout the study (136 days). This is the first study that evaluates the stability of these compounds in oral fluid samples after application in DSS cards, and optimizes the conditions in order to improve their stability.
Collapse
|
53
|
Smith CR, Swortwood MJ. Analysis of methylphenidate, ethylphenidate, lisdexamfetamine, and amphetamine in oral fluid by liquid chromatography-tandem mass spectrometry. J Forensic Sci 2022; 67:669-675. [PMID: 34985135 DOI: 10.1111/1556-4029.14977] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/19/2021] [Accepted: 12/21/2021] [Indexed: 11/30/2022]
Abstract
Oral fluid is an alternative matrix that has proven to be useful for the detection of drugs. Oral fluid is easy to collect, noninvasive, and may indicate recent drug use. There are limited methods available that analyze cognitive stimulants in oral fluid. Cognitive stimulants are used to treat attention-deficit/hyperactivity disorder (ADHD), a neurological disorder that emerges from lack of dopamine in the brain. To combat this disorder, medications inhibit dopamine and norepinephrine reuptake by blocking transporters in the brain. Though commonly diagnosed in children, ADHD may extend beyond adolescence and abuse of medications in college students is not uncommon. The goal of this study was to develop and validate a quantitative method for methylphenidate, ethylphenidate, lisdexamfetamine, and amphetamine in oral fluid using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Analytes were isolated by solid-phase extraction and analyzed on an Agilent 1290 Infinity II Liquid Chromatograph coupled to an Agilent 6470 Triple Quadrupole Mass Spectrometer. The linear range was 0.5-100 ng/ml (except lisdexamfetamine at 5-500 ng/ml). Bias and between-run precision were acceptable (±11.0% bias and ±12.2%CV). No interferences or carryover were observed and dilution integrity was sustained. This validated method was applied to four authentic oral fluid samples collected with Quantisal® devices from college students. Lisdexamfetamine was quantified in one sample at 5.8 ng/ml while amphetamine was quantified in all four samples at 6.0-78.8 ng/ml. This is the first known quantitative method in oral fluid that includes these analytes using LC-MS/MS and may give rise to interpretive value in a forensic toxicology setting.
Collapse
|
54
|
Myakotnykh VS, Sidenkova AP, Kharitonova MP, Meshchaninov VN, Melnik AA, Khilyuk DA. [The state of the oral cavity in early diagnosis and predicting cognitive disorders.]. ADVANCES IN GERONTOLOGY = USPEKHI GERONTOLOGII 2022; 35:418-428. [PMID: 36169371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
A review of the literature on the problem of the use of non-invasive technologies in early diagnosis and prediction of age-associated cognitive decline associated with Alzheimer's disease is presented. The main attention is paid to the study of the buccal epithelium, oral fluid, as surrogate models of degenerative lesions of cerebral structures, as well as determining the role of oral microorganisms in the formation and development of cognitive disorders. An original hypothesis of neurodegenerative lesions of cerebral structures is presented, on the basis of which an algorithm for studying the state of the oral cavity is proposed in order to detect and predict cognitive deficits as early as possible.
Collapse
|
55
|
Insights into the Oral Bacterial Microbiota of Sows. Microorganisms 2021; 9:microorganisms9112314. [PMID: 34835441 PMCID: PMC8619539 DOI: 10.3390/microorganisms9112314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 10/25/2021] [Accepted: 11/03/2021] [Indexed: 11/16/2022] Open
Abstract
The investigation of bacterial microbiota represents a developing research field in veterinary medicine intended to look for correlations between animal health and the balance within bacterial populations. The aim of the present work was to define the bacterial microbiota of the oral cavity of healthy sows, which had not been thoroughly described so far. In total, 22 samples of oral fluid were collected and analyzed by 16S-rRNA gene sequencing. CLC Genomics Workbench 20.0 (QIAGEN Digital Insights, Aarhus, Denmark) was then used to examine the results. The predominant orders were Lactobacillales, Clostridiales, and Corynebacteriales. Lactobacillaceae, Corynebacteriaceae, Moraxellaceae, Aerococcaceae, and Staphylococcaceae were the most represented families. As regards the most abundant genera, Lactobacillus, Corynebacterium, Acinetobacter, Staphylococcus, Rothia, Aerococcus, and Clostridium can be pointed out as the bacterial core microbiota. Sows were also divided into “gestating” and “lactating” groups, and mild differences were found between pregnant and lactating sows. The data herein described represent an original contribution to the knowledge of the porcine bacterial microbiota. Moreover, the choice of sows as experimental animals was strategic for identifying the adult microbial community. These data provide a basis for further studies on the oral bacterial microbiota of pigs.
Collapse
|
56
|
Vincenti F, Montesano C, Pirau S, Gregori A, Di Rosa F, Curini R, Sergi M. Simultaneous Quantification of 25 Fentanyl Derivatives and Metabolites in Oral Fluid by Means of Microextraction on Packed Sorbent and LC-HRMS/MS Analysis. Molecules 2021; 26:molecules26195870. [PMID: 34641416 PMCID: PMC8512571 DOI: 10.3390/molecules26195870] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/22/2021] [Accepted: 09/24/2021] [Indexed: 11/16/2022] Open
Abstract
Fentanyl and fentalogs’ intake as drugs of abuse is experiencing a great increase in recent years. For this reason, there are more and more cases in which it is important to recognize and quantify these molecules and related metabolites in biological matrices. Oral fluid (OF) is often used to find out if a subject has recently used a psychoactive substance and if, therefore, the person is still under the effect of psychotropics. Given its difficulty in handling, good sample preparation and the development of instrumental methods for analysis are essential. In this work, an analytical method is proposed for the simultaneous determination of 25 analytes, including fentanyl, several derivatives and metabolites. OF was collected by means of passive drool; sample pretreatment was developed in order to be fast, simple and possibly semi-automated by exploiting microextraction on packed sorbent (MEPS). The analysis was performed by means of LC–HRMS/MS obtaining good identification and quantification of all the analytes in less than 10 min. The proposed method was fully validated according to the Scientific Working Group for Forensic Toxicology (SWGTOX) international guidelines. Good results were obtained in terms of recoveries, matrix effect and sensitivity, showing that this method could represent a useful tool in forensic toxicology. The presented method was successfully applied to the analysis of proficiency test samples.
Collapse
|
57
|
Ortega J, Infantes-Lorenzo JA, Bezos J, Roy Á, de Juan L, Romero B, Moreno I, Gómez-Buendía A, Agulló-Ros I, Domínguez L, Domínguez M. Evaluation of P22 ELISA for the Detection of Mycobacterium bovis-Specific Antibody in the Oral Fluid of Goats. Front Vet Sci 2021; 8:674636. [PMID: 34458351 PMCID: PMC8385241 DOI: 10.3389/fvets.2021.674636] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/20/2021] [Indexed: 11/13/2022] Open
Abstract
The ante-mortem diagnosis of tuberculosis (TB) in ruminants is based mainly on the intradermal tuberculin test and the IFN-γ assay. Antibody (Ab)-based tests have emerged as potential tools for the detection of TB infected animals using serum, plasma, or even milk samples. Oral fluids have also been evaluated as alternative samples with which to detect specific Abs against Mycobacterium bovis in pigs or wild boars, but not in ruminants. The objective of this study was, therefore, to evaluate the performance of an in house-ELISA for TB diagnosis (P22 ELISA) in goats as an experimental model for the diagnosis of TB using oral fluid samples. Oral fluid samples from 64 goats from a TB-infected herd (n = 197) and all the animals from a TB-free herd (n = 113) were analyzed using the P22 ELISA. The estimated sensitivity (Se) and specificity (Sp) were 34.4% (95% CI: 22.4–45.6) and 100% (95% CI: 97.4–100), respectively. The optimal cut-off point was set at 100% according to the ROC analysis. Those animals with a higher level of Abs in their oral fluid attained a higher lesion score (p = 0.018). In fact, when taking into account only the setting of the animals with severe lesions (n = 16), the ELISA showed a Se of 75% (95% CI: 53.7–96.2). Results of the present study suggest that the P22 ELISA is highly specific but has a limited value detecting infected animals in oral fluid samples. Nevertheless, its performance is significantly higher in the presence of severe lesions.
Collapse
|
58
|
Gorziza RP, Duarte JA, González M, Arroyo-Mora LE, Limberger RP. A systematic review of quantitative analysis of cannabinoids in oral fluid. J Forensic Sci 2021; 66:2104-2112. [PMID: 34405898 DOI: 10.1111/1556-4029.14862] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 07/12/2021] [Accepted: 08/03/2021] [Indexed: 11/30/2022]
Abstract
Cannabis sativa L. is a substance widely used around the world for recreational and medicinal purposes. Oral fluid has been investigated as an alternative biological matrix for demonstrating the illegal use of cannabis, particularly in situations where its recent use needs to be identified. In the last two decades, many methods have been developed to detect and quantify cannabinoids in oral fluid, especially for Δ9 -tetrahydrocannabinol, the primary psychoactive substance of cannabis. However, some aspects must be considered in the use of these techniques, such as cannabinoids recoveries or extraction efficiency from different oral fluid collection devices/containers. Pharmacokinetic studies have shown that the presence of minor cannabinoids and metabolites in the analysis of oral fluid may be valuable in interpreting tests, which indicates the need to improve the sensitivity of detecting low concentrations. The aim of this review is to summarize and to describe the methodologies for the quantitative analysis of cannabinoids in oral fluid that have previously been investigated. A systematic search for articles was performed of four different databases, using the descriptor "cannabinoids and oral fluid". Forty-seven studies that examined quantitative methods were identified. The analytical data described in these articles, including oral fluid collection, sample preparation, cannabinoids recovery and extraction efficiency, detection instruments, and quantification limits, were analyzed. The discussion of these particular features of cannabinoid analysis in oral fluid could help to improve or to develop methods for use in Forensic Toxicology.
Collapse
|
59
|
McCartney D, Kevin RC, Suraev AS, Irwin C, Grunstein RR, Hoyos CM, McGregor IS. Orally administered cannabidiol does not produce false-positive tests for Δ 9 -tetrahydrocannabinol on the Securetec DrugWipe® 5S or Dräger DrugTest® 5000. Drug Test Anal 2021; 14:137-143. [PMID: 34412166 PMCID: PMC9292716 DOI: 10.1002/dta.3153] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/21/2021] [Accepted: 08/16/2021] [Indexed: 11/25/2022]
Abstract
Many jurisdictions use point‐of‐collection (POC) oral fluid testing devices to identify driving under the influence of cannabis, indexed by the presence of Δ9‐tetrahydrocannabinol (THC), an intoxicating cannabinoid, in oral fluid. Although the use of the non‐intoxicating cannabinoid, cannabidiol (CBD), is not prohibited among drivers, it is unclear whether these devices can reliably distinguish between CBD and THC, which have similar chemical structures. This study determined whether orally administered CBD produces false‐positive tests for THC on standard, POC oral fluid testing devices. In a randomised, double‐blind, crossover design, healthy participants (n = 17) completed four treatment sessions involving the administration of either placebo or 15‐, 300‐ or 1500‐mg pure CBD in a high‐fat dietary supplement. Oral fluid was sampled, and the DrugWipe®‐5S (DW‐5S; 10 ng·ml−1 THC cut‐off) and Drug Test® 5000 (DT5000; 10 ng·mL−1 THC cut‐off) devices administered, at baseline (pretreatment) and ~20‐, ~145‐ and ~185‐min posttreatment. Oral fluid cannabinoid concentrations were measured using ultra‐high performance liquid chromatography–tandem mass spectrometry. Median (interquartile range [IQR]) oral fluid CBD concentrations were highest at ~20 min, quantified as 0.4 (6.0), 15.8 (41.6) and 167 (233) ng·ml−1 on the 15‐, 300‐ and 1500‐mg CBD treatments, respectively. THC, cannabinol and cannabigerol were not detected in any samples. A total of 259 DW‐5S and 256 DT5000 tests were successfully completed, and no THC‐positive tests were observed. Orally administered CBD does not appear to produce false‐positive (or true‐positive) tests for THC on the DW‐5S and DT5000. The likelihood of an individual who is using a CBD (only) oral formulation being falsely accused of DUIC therefore appears low.
Collapse
|
60
|
De Lucia A, Cawthraw SA, Smith RP, Davies R, Bianco C, Ostanello F, Martelli F. Pilot Investigation of Anti- Salmonella Antibodies in Oral Fluids from Salmonella Typhimurium Vaccinated and Unvaccinated Swine Herds. Animals (Basel) 2021; 11:ani11082408. [PMID: 34438865 PMCID: PMC8388757 DOI: 10.3390/ani11082408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 08/01/2021] [Accepted: 08/12/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary The consumption of pork meat is responsible for a significant number of outbreaks of salmonellosis in people. Surveillance in pig herds is constrained by the cost-effectiveness and efficiency of sampling methods. The last decade has seen significant advances in the routine use of pool samples, including oral fluids (OFs). This study aimed to investigate the OF collected passively via chewed sampling ropes as a potential sample type for assessing anti-Salmonella antibodies in two Salmonella-vaccinated (V) and two non-vaccinated (NV) farrow-to-finish pig farms, comparing the results with the Salmonella shedding of tested animals. Sows in the V farms were vaccinated prior to farrowing. Pooled faecal and OF samples were collected from sows and their offspring. Salmonella was isolated with direct bacteriological methods. A commercial ELISA assay was adapted to detect IgG and IgA antibodies in OF. Overall, a higher Salmonella prevalence was observed in the NV farm and in the offspring (76.3%) compared to sows (36.4%). The protocol used to test anti-Salmonella IgA in pig OF samples was found to lack sensitivity and specificity. At herd level, IgG is the most reliable isotype for monitoring Salmonella specific antibody via OF. Abstract Oral fluid (OF) can be a simple, cheap and non-invasive alternative to serum or meat juice for the diagnosis and surveillance of important pathogens in pigs. This study was conducted on four Salmonella Typhimurium-positive farrow-to-finish pig farms: two Salmonella-vaccinated (V) and two non-vaccinated (NV). Gilts and sows in the V farms were vaccinated with a live, attenuated vaccine prior to farrowing. Pooled faecal and OF samples were collected from the sows and their offspring. Salmonella was isolated according to ISO6579–1:2017. In parallel, IgG and IgA levels were assessed in OF samples using a commercial ELISA assay. Salmonella was detected in 90.9% of the pooled faecal samples from the NV farms and in 35.1% of the pooled faecal samples from the V farms. Overall, a higher prevalence was observed in the pooled faecal samples from the offspring (76.3%) compared to the sows (36.4%). IgG antibodies measured in V farms are likely to be related to vaccination, as well as exposure to Salmonella field strains. The detection of IgA antibodies in OF was unreliable with the method used. The results of this study show that IgG is the most reliable isotype for monitoring Salmonella-specific antibody immunity in vaccinated/infected animals via OF.
Collapse
|
61
|
Chaulin A. Clinical and Diagnostic Value of Highly Sensitive Cardiac Troponins in Arterial Hypertension. Vasc Health Risk Manag 2021; 17:431-443. [PMID: 34366667 PMCID: PMC8336985 DOI: 10.2147/vhrm.s315376] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 07/02/2021] [Indexed: 12/13/2022] Open
Abstract
In modern laboratory diagnostics of cardiovascular diseases (CVD), there is a clear tendency toward an increase in the sensitivity of methods for determining key CVD biomarkers, among which highly sensitive cardiac troponins (hs-Tn) deserve special attention. The introduction of the latter into clinical practice made it possible not only to improve the early diagnosis of acute myocardial infarction but also to open up a number of additional valuable opportunities for the use of hs-Tn, including the assessment of the risk of developing CVD in a healthy population, detection and monitoring of early myocardial injuries in the early stages of CVD development (for example, with ischemic heart disease and arterial hypertension), with noncardiac pathologies (for example, sepsis, chronic obstructive pulmonary disease, chronic renal failure, stroke, cancer, etc), and diagnostics of CVD by using biological fluids that can be obtained by noninvasive methods. This article discusses in detail the diagnostic value of hs-Tn in serum and urine in cases of arterial hypertension. Also, the paper pays considerable attention to the consideration of the mechanisms underlying the increase in hs-Tn in serum and urine in cases of arterial hypertension.
Collapse
|
62
|
Mahowald GK, Khaliq TP, Griggs D, O M, Flood JG, Uljon S. Comparison of Oral Fluid and Urine for Detection of Fentanyl Use Using Liquid Chromatography with Tandem Mass Spectrometry. J Appl Lab Med 2021; 6:1533-1540. [PMID: 34327523 DOI: 10.1093/jalm/jfab068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 06/07/2021] [Indexed: 11/13/2022]
Abstract
BACKGROUND We compared oral fluid (OF) and urine (UR) for detection of fentanyl (FEN) use in addiction medicine-psychiatry (AMP) clinics. METHODS We measured FEN and norfentanyl (NRFEN) in UR with a limit of detection (LOD) of 2.0 µg/L and FEN in OF with an LOD of 0.5 µg/L by LC-MS/MS in 311 paired samples and compared the 2 matrices when higher OF and UR LODs were used. RESULTS Urine (UR) detected more FEN use than OF using a LOD of 2.0 µg/L and 0.5 µg/L, respectively. FEN and/or NRFEN were detected in 44 and 59 UR specimens, respectively, and FEN in 46 OF specimens (43 OF+UR+, 3 OF+UR-, 16 OF-UR+, and 249 OF-UR-). In UR there were no instances with FEN positive and NORFEN negative. UR creatinine was <20 mg/dL in the 3 OF+UR- specimen pairs. The median OF/UR analyte concentration ratios in positive sample pairs were 0.23 for OF FEN/UR FEN and 0.02 for OF FEN/UR NRFEN. CONCLUSIONS We demonstrate that UR detects more FEN use than OF in an AMP setting when UR FEN and UR NORFEN LODs of 2.0 µg/L are used. OF is less sensitive than UR in detecting FEN use, but is still valuable for cases with low UR creatinine and/or suspected adulteration or substitution of UR. The UR vs OF comparison statistics are greatly impacted by even minimal adjustments of the LOD.
Collapse
|
63
|
Palmquist KB, Swortwood MJ. Quantification of fentanyl analogs in oral fluid using LC-QTOF-MS. J Forensic Sci 2021; 66:1871-1878. [PMID: 34287912 DOI: 10.1111/1556-4029.14813] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/06/2021] [Accepted: 07/08/2021] [Indexed: 11/28/2022]
Abstract
Oral fluid is a valuable alternative matrix for forensic toxicologists due to ease of observed collection, limited biohazardous exposure, and indications of recent drug use. Limited information is available for fentanyl analog prevalence, interpretation, or analysis in oral fluid. With increasing numbers of fentanyl-related driving under the influence of drug (DUID) cases appearing in the United States, the development of detection methods is critical. The purpose of the present study was to develop and validate a quantitative method for fentanyl analogs in oral fluid (collected via Quantisal™) using liquid chromatography-quadrupole-time-of-flight-mass spectrometry (LC-QTOF-MS). Validation resulted in limits of detection and quantification ranging from 0.5 to 1 ng/mL. Established linear range was 1-100 ng/mL for all analytes, except acetyl fentanyl at 0.5-100 ng/mL (R2 > 0.994). Within- and between-run precision and bias were considered acceptable with maximum values of ±15.2%CV and ±14.1%, respectively. Matrix effects exhibited ionization enhancement for all analytes with intensified enhancement at a low concentration (9.3-47.4%). No interferences or carryover was observed. Fentanyl analogs were stable in processed extracts stored in the autosampler (4⁰ C) for 48h. The validated method was used to quantify fentanyl analogs in authentic oral fluid samples (n=17) from probationers/parolees. Fentanyl and 4-ANPP concentrations were 1.0-104.5 ng/mL and 1.2-5.7 ng/mL, respectively.
Collapse
|
64
|
Lierheimer S, Beck O, Keller T, Monticelli FC, Böttcher M. Hydromorphone and codeine concentrations in oral fluid specimens from patients receiving substitution therapy with Substitol™ (morphine sulfate). Drug Test Anal 2021; 13:1743-1748. [PMID: 34250761 DOI: 10.1002/dta.3127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/30/2021] [Accepted: 07/07/2021] [Indexed: 11/07/2022]
Abstract
This study aimed to determine whether hydromorphone and codeine can be detected in oral fluid specimens following administration of Substitol™, a slow-release formulation of morphine. This is of interest for those monitoring treatment compliance using drug testing. Oral fluid specimens collected for compliance assessment in routine clinical practice or as part of a clinical trial were subjected to quantitative analysis of hydromorphone, morphine, codeine, and 6-acetylmorphine using highly sensitive mass spectrometric methods. Oral fluid was collected using a Greiner Bio-One saliva collection system. Patients undergoing substitution treatment with Substitol™, methadone, or buprenorphine were included, together with patients undergoing pain treatment with hydromorphone. Hydromorphone was detected in 642 of the 663 (97%) samples from substitol-treated patients. Concentrations were not higher in methadone- and buprenorphine-treated patients who relapsed into heroin use, or in patients on hydromorphone therapy. Codeine was detected in 29% of the samples. These concentrations were lower than those in patients who had relapsed to heroin use. Clinical administration of morphine can lead to detectable concentrations of both hydromorphone and codeine in oral fluids. This should be taken into consideration when using drug testing in oral fluid samples for compliance assessment in this patient group.
Collapse
|
65
|
Hubbard JA, Hoffman MA, Ellis SE, Sobolesky PM, Smith BE, Suhandynata RT, Sones EG, Sanford SK, Umlauf A, Huestis MA, Grelotti DJ, Grant I, Marcotte TD, Fitzgerald RL. Biomarkers of Recent Cannabis Use in Blood, Oral Fluid and Breath. J Anal Toxicol 2021; 45:820-828. [PMID: 34185831 DOI: 10.1093/jat/bkab080] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/15/2021] [Accepted: 07/07/2021] [Indexed: 12/25/2022] Open
Abstract
Proving driving under the influence of cannabis (DUIC) is difficult. Establishing a biomarker of recent use to supplement behavioral observations may be a useful alternative strategy. We determined whether cannabinoid concentrations in blood, oral fluid (OF), or breath could identify use within 3h, likely the period of greatest impairment. In a randomized trial, 191 frequent (≥4/week) and occasional (<4/week) cannabis users smoked one cannabis (placebo [0.02%], 5.9% or 13.4% THC) cigarette ad libitum. Blood, OF and breath samples were collected prior to and up to 6h after smoking. Samples were analyzed for 10 cannabinoids in OF, 8 in blood, and THC in breath. Frequent users had more residual THC in blood and were categorized as "recently used" prior to smoking; this did not occur in OF. Per se limits ranging from undetectable to 5 ng/mL THC in blood offered limited usefulness as biomarkers of recent use. Cannabinol (CBN, cutoff=1 ng/mL) in blood offered 100% specificity but only 31.4% sensitivity, resulting in 100% PPV and 94.0% NPV at 4.3% prevalence; but CBN may vary by cannabis chemovar. A 10 ng/mL THC cutoff in OF exhibited the overall highest performance to detect use within 3h (99.7% specificity, 82.4% sensitivity, 92.5% PPV, 99.2% NPV) but was still detectable in 23.2% of participants ~4.4h post smoking limiting specificity at later time points. OF THC may be a helpful indicator of recent cannabis intake, but this does not equate to impairment. Behavioral assessment of impairment is still required to determine DUIC. This study only involved cannabis inhalation and additional research evaluating alternative routes of ingestion (i.e., oral) is needed.
Collapse
|
66
|
Hoffman MA, Hubbard JA, Sobolesky PM, Smith BE, Suhandynata RT, Sanford S, Sones E, Ellis S, Umlauf A, Huestis MA, Grelotti DJ, Grant I, Marcotte TD, Fitzgerald RL. Blood and Oral Fluid Cannabinoid Profiles of Frequent and Occasional Cannabis Smokers. J Anal Toxicol 2021; 45:851-862. [PMID: 34173005 DOI: 10.1093/jat/bkab078] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/14/2021] [Accepted: 06/25/2021] [Indexed: 01/14/2023] Open
Abstract
Increased prevalence of cannabis consumption and impaired driving are a growing public safety concern. Some states adopted per se driving laws, making it illegal to drive with more than a specified ∆9-tetrahydrocannabinol (THC) blood concentration of THC in a biological fluid (typically blood). Blood THC concentrations decrease significantly (~90%) with delays in specimen collection, suggesting use of alternative matrices, such as oral fluid (OF). We characterized 10 cannabinoids' concentrations, including THC metabolites, in blood and OF from 191 frequent and occasional users by LC-MS-MS for up to 6 h after ad libitum smoking. Subjects self-titrated when smoking placebo, 5.9 or 13.4% THC cannabis. Higher maximum blood THC concentrations (Cmax) were observed in individuals who received the 5.9% THC versus the 13.4% THC plant material. In blood, the Cmax of multiple analytes, including THC and its metabolites, were increased in frequent compared to occasional users, whereas there were no significant differences in OF Cmax. Blood THC remained detectable (≥5 ng/mL) at the final sample collection for 14% of individuals who smoked either the 5.9% or 13.4% THC cigarette, whereas 54% had detectable THC in OF when applying the same cutoff. Occasional and frequent cannabis users' profiles were compared, THC was detectable for significantly longer in blood and OF from frequent users. Detection rates between frequent and occasional users at multiple per se cutoffs showed larger differences in blood versus OF. Understanding cannabinoid profiles of frequent and occasional users and the subsequent impact on detectability with current drug per se driving limits is important to support forensic interpretations and the development of scientifically supported driving under the influence of cannabis laws.
Collapse
|
67
|
Goonewardene KB, Chung CJ, Goolia M, Blakemore L, Fabian A, Mohamed F, Nfon C, Clavijo A, Dodd KA, Ambagala A. Evaluation of oral fluid as an aggregate sample for early detection of African swine fever virus using four independent pen-based experimental studies. Transbound Emerg Dis 2021; 68:2867-2877. [PMID: 34075717 DOI: 10.1111/tbed.14175] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 05/29/2021] [Indexed: 11/29/2022]
Abstract
The sustained spread of African swine fever (ASF) virus throughout much of the world has made ASF a global animal health priority, with an increased emphasis on enhancing preparedness to prevent, detect and respond to a potential outbreak of ASF virus (ASFV). In the event of ASFV entry to the North American swine population, enhanced surveillance and diagnostic testing strategies will be critical to facilitate progressive response and eradication of the disease. Compared to individual animal sampling, pen-based oral fluid collection for active surveillance is a non-invasive alternative that is less resource and time-intensive. To evaluate the feasibility of using rope-based oral fluid for early detection of ASFV, four independent animal experiments were conducted in weaned pigs housed in numbers that mimic the industry settings, utilising either highly virulent ASFV Georgia 2007/1 strain or moderately virulent ASFV Malta'78 strain. Pen-based oral fluid and individual oropharyngeal swabs were collected daily and blood samples from each animal were collected every other day. All samples were subsequently tested for ASFV by real-time PCR. ASFV genome was detected in individual blood samples as early as one day post-infection and detected in oral fluids at low-to-moderate levels as early as 3-5 days post-infection in all four independent experiments. These results suggest that pen-based oral fluid samples may be used to supplement the use of traditional samples for rapid detection of ASFV during ASF surveillance.
Collapse
|
68
|
Coulter C, Wagner JR. Cannabinoids in Oral Fluid: Limiting Potential Sources of Cannabidiol Conversion to Δ9- and Δ8-Tetrahydrocannabinol. J Anal Toxicol 2021; 45:807-812. [PMID: 34137890 DOI: 10.1093/jat/bkab074] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 06/09/2021] [Accepted: 06/16/2021] [Indexed: 12/20/2022] Open
Abstract
In late 2019 the National Laboratory Certification Program (NLCP) published an article reporting on the potential analytical conversion of 7-carboxy-cannabidiol (CBD-COOH) to 11-nor-9-carboxy-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. (1) The same conversion is possible in oral fluid with the parent analyte cannabidiol (CBD) converting to Δ9-tetrahydrocannabinol (Δ9-THC) and Δ8-tetrahydrocannabinol (Δ8-THC) under strong acidic conditions. With the recent rise in states legalizing the use of THC and the availability of products containing only CBD, unless the analytical in vitro conversions are controlled, the detection of Δ9-THC or Δ8-THC in oral fluid may not clarify whether the donor was using a CBD product, licit or illicit THC product. Authentic oral fluid samples submitted for cannabinoid analysis were subjected to multiple sample preparation procedures and extraction methods to determine the conditions that allow CBD to convert to THC. CBD single analyte controls prepared from a certified THC-free source were added to the batch to monitor the rate of conversion. Samples were prepared using a base hydrolysis, solid phase extraction, derivatization, and analysis by liquid chromatography with tandem mass spectrometry (LC-MS-MS). The base hydrolysis and derivatization were tested independently and did not contribute to the conversion rate. Adjusting the pH of the sample preparation and extraction from pH 2.0 to pH 5.0 changed the conversion rate from 5% to 1%. A pH of 6.0 was not strong enough to extract the cannabinoids efficiently. Removing the acid component of the preparation and extraction procedure eliminated the conversion to THC; however, this did reduce the analyte recovery depending on which extraction column was used. Processing time also contributed to the conversion rate. With smaller trial runs, conversion was not always seen but with larger validation batches low level conversion of 1-2% was observed. A fully validated LC-MS-MS method utilizing solid-phase extraction was developed for CBD, Δ9-THC, Δ8-THC, and cannabinol (CBN). The method specifically targets those analytes found in oral fluid after CBD administration and those that are seen during in vitro CBD conversion. CBD administration was performed using a certified THC-free CBD control.
Collapse
|
69
|
Chauncey S, Hobbs GA. An automated assay for salivary amylase: A validity marker for oral fluid. Drug Test Anal 2021; 13:1452-1456. [PMID: 33668073 DOI: 10.1002/dta.3023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/24/2021] [Accepted: 03/02/2021] [Indexed: 11/06/2022]
Abstract
Oral fluid is a matrix well suited to use in teletherapy. However, in cases where direct observation is not possible, validity of the specimen is in question. We have adapted a commercial salivary amylase assay for use with the Quantisal™ oral fluid collection system. We have demonstrated acceptable analytical performance and determined a cutoff to distinguish valid from invalid oral fluid specimens. We determined that washing a donor's mouth with water was unlikely to a produce a falsely invalid result if the normal 10 min passes between drinking or eating and oral fluid collection. We conclude that the measurement of salivary amylase is useful for the determination of oral fluid specimen validity in cases where direct observation of the specimen collection is not possible. This feature would be most important in a teletherapy setting, which often does not include a video component. This study describes how an assay for salivary amylase may be used to establish possible substitution. This assay does not rule out adulteration.
Collapse
|
70
|
Positivity to Cocaine and/or Benzoylecgonine in Confirmation Analyses for On-Road Tests in Spain. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18105371. [PMID: 34070008 PMCID: PMC8157855 DOI: 10.3390/ijerph18105371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/13/2021] [Accepted: 05/15/2021] [Indexed: 11/16/2022]
Abstract
We are using real-life data in order to determine the prevalence of driving with the presence of cocaine and/or benzoylecgonine (BZE), their concentrations, and their use in combination with other drugs. This study assessed data on Spanish drivers with confirmed drug-positive results recorded by the Spanish National Traffic Agency from 2011-2016. Frequencies of positivity for cocaine and/or BZE and concentration of such substances were obtained. Comparisons and univariate and multivariate regression analyses were performed. Drivers who tested positive for cocaine and/or BZE accounted for 48.59% of the total positive results for drugs. In positive cases for both cocaine and BZE, other substances were detected in 81.74%: delta-9-tetrahydrocannabinol (THC) (68.19%), opioids (20.78%) and amphetamine-like substances (16.76%). In the multivariate logistic regression analysis, the frequency of cocaine and/or BZE positive cases decreased with age (OR:0.97) and were less likely among women (OR:0.63). Concentrations (ng/mL) of cocaine (249.30) and BZE (137.90) were higher when both substances were detected together than when detected alone. Positivity to cocaine represented an important proportion among Spanish drivers who tested positive for drugs, and polysubstance use was especially observed in more than 8 out of 10 positive cases for cocaine and/or BZE.
Collapse
|
71
|
Clavijo MJ, Hu D, Krantz S, Cano JP, Pereira Maróstica T, Henao-Diaz A, Poeta Silva APS, Hemker D, Tapia E, Zimmerman S, Fano E, Polson D, Fitzgerald R, Tucker A, Main R, Wang C, Zimmerman JJ, Rotolo ML. Mycoplasma hyopneumoniae Surveillance in Pig Populations: Establishing Sampling Guidelines for Detection in Growing Pigs. J Clin Microbiol 2021; 59:e03051-20. [PMID: 33597256 PMCID: PMC8091834 DOI: 10.1128/jcm.03051-20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 02/06/2021] [Indexed: 02/04/2023] Open
Abstract
Antemortem detection of Mycoplasma hyopneumoniae infection in swine production systems has relied on antibody testing, but the availability of tests based on DNA detection and novel diagnostic specimens, e.g., tracheal swabs and oral fluids, has the potential to improve M. hyopneumoniae surveillance. A field study was performed over a 14-week period during which 10 pigs in one pen at the center of a room with 1,250 6-week-old pigs housed in 46 pens were intratracheally inoculated with M. hyopneumoniae Thereafter, one tracheal sample, four serum samples, and one oral fluid sample were collected from every pen at 2-week intervals. Tracheal and oral fluid samples were tested for M. hyopneumoniae DNA and serum samples for M. hyopneumoniae antibody. Test results were modeled using a hierarchical Bayesian model, based on a latent spatial piecewise exponential survival model, to estimate the probability of detection by within-pen prevalence, number of positive pens in the barn, sample allocation, sample size, and sample type over time. Analysis showed that tracheal samples provided the earliest detection, especially at large sample sizes. While serum samples are more commonly collected and are less expensive to test, high probability of detection estimates were only obtained 30 days postexposure at large sample sizes. In all scenarios, probability of detection estimates for oral fluids within 30 days were significantly lower than those for tracheal and serum samples. Ultimately, the choice of specimen type, sample number, and assay will depend on testing objectives and economics, but the estimates provided here will assist in the design of M. hyopneumoniae surveillance and monitoring programs for different situations.
Collapse
|
72
|
Gilmiyarova FN, Gusyakova OA, Konstantinov DY, Selezneva IA, Borodina IA, Kolotyeva NA, Konstantinova EA, Tlustenko VS, Lebedeva SS, Temnik EI, Remizov VV. Molecular profile of oral fluid in new coronavirus infection. Klin Lab Diagn 2021; 66:133-138. [PMID: 33793111 DOI: 10.51620/0869-2084-2021-66-3-133-138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Oral fluid is an alternative biological material that confirms correlations with blood parameters in various pathological conditions of the body. In order to find a non-invasive approach to stratification of patients with COVID-19 disease, molecular biomarkers of the oral fluid have been determined in patients with moderate coronavirus infection in comparison with clinically healthy individuals. It has been shown that proteomic, carbohydrate, macro- and microelement profiles of the oral fluid in coronavirus infection can be used for diagnostics. The features of protein metabolism were revealed: an increase in the content of total protein, urea; increased activity of enzymes aspartate aminotransferase, gamma glutamyl transpeptidase, creatine phosphokinase, alkaline phosphatase; changes in carbohydrate metabolism, which is expressed by an increase in glucose and lactate levels, an increase in lactate dehydrogenase activity, sodium, chloride, calcium, magnesium, iron content.
Collapse
|
73
|
Bartonella henselae Antibodies in Serum and Oral Fluid Specimens from Cats. Pathogens 2021; 10:pathogens10030329. [PMID: 33799577 PMCID: PMC8001045 DOI: 10.3390/pathogens10030329] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/05/2021] [Accepted: 03/07/2021] [Indexed: 11/17/2022] Open
Abstract
Cats are the primary reservoir host for Bartonella henselae(B. henselae), an etiological agent of human bartonellosis, including cat scratch disease. Although Bartonella DNA has been amplified from salivary swabs from cats, dogs and humans, we are not aware of studies investigating Bartonella antibodies in oral fluid (OF). Using inhouse and commercial immunofluorescence antibody assays (IFA), the objective of this study was to detect and compare antibodies against B. henselae in paired OF and serum specimens from cats. Specimens were collected from shelter and client-owned cats. For serum specimens, B. henselae seroreactivity was 78% for both the inhouse and commercial IFA assays and 56.8% for OF specimens. Comparing serum and OF specimens, there was moderate Kappa agreement (Cohen's k = 0.434) for detection of B. henselae antibodies. Oral fluid antibodies were more likely measurable in cats with high B. henselae serum antibody titers when compared with low antibody titers. In conclusion, B. henselae OF IFA antibody measurements were less sensitive compared to serum IFA measurements of ≥1:64. Oral fluid antibodies were detected more often in cats with high B. henselae serum antibody titers. Therefore, OF antibodies, detectable by IFA, is of limited utility for epidemiological or diagnostic testing in cats.
Collapse
|
74
|
Magura S, Weller BE, Smith DR, Saxton MM, Amaratunga P. Surveillance by oral fluid of drugs subject to misuse among individuals under arrest. THE AMERICAN JOURNAL OF DRUG AND ALCOHOL ABUSE 2021; 47:247-254. [PMID: 33481634 DOI: 10.1080/00952990.2020.1860075] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Background: Between 1988 and 2013 the U.S. government conducted surveillance of national drug misuse use trends by collecting voluntary urine specimens from individuals under arrest in major counties. It was discontinued for financial reasons. The program was the only national survey that used a bioassay to measure drug use. Other national drug surveys continue to be based entirely on self-reports of drug use.Objective: Given the current opioid and incipient methamphetamine epidemics, this study aimed to demonstrate the feasibility of surveilling drugs subject to misuse among individuals under arrest using oral fluid collected anonymously by jail staff in one U.S. county. This method has never been previously employed with an offender population.Methods: The subjects were adults arrested for any reason and booked in one Midwest county jail in the U.S. between July 2019 - January 2020 (N = 196; 145 males). Oral fluid specimens were provided for research purposes voluntarily and anonymously.Results: 79% of individuals approached consented to participation. The most frequently detected drugs were cannabis (53%), methamphetamine (27%), cocaine (9%) and opioids (11%). Further, 74% tested positive for at least one drug; 36% tested positive for at least one illegal drug, 10% tested positive for at least one possibly illegal drug, and 54% tested positive for at least one legal drug (predominantly cannabis). (Tests for nicotine and ethanol were not included.)Conclusion: The feasibility of collecting oral fluid from individuals under arrest in a jail setting to measure the prevalence of drugs subject to misuse was demonstrated.
Collapse
|
75
|
Acceptability and Usability of HCV Self-Testing in High Risk Populations in Vietnam. Diagnostics (Basel) 2021; 11:diagnostics11020377. [PMID: 33672241 PMCID: PMC7926709 DOI: 10.3390/diagnostics11020377] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Revised: 02/17/2021] [Accepted: 02/19/2021] [Indexed: 02/08/2023] Open
Abstract
HIV self-testing has emerged as a safe and effective approach to increase the access to and uptake of HIV testing and treatment, especially for key populations. Applying self-testing to hepatitis C virus (HCV) may also offer an additional way to address low coverage of HCV testing and to accelerate elimination efforts. To understand the potential for HCV self-testing (HCVST), an observational study was conducted to assess the acceptability and usability of the OraQuick® HCV Self-Test (prototype) among people who inject drugs (PWID) and men who have sex with men (MSM) in Thai Nguyen, a province in northern Vietnam. A total of 105 PWID and 104 MSM were eligible and agreed to participate in the study. Acceptability, defined as the proportion of participants among eligible subjects who agreed to participate in the study, was 92.9% in PWID and 98.6% in MSM. Compared to MSM, PWID were older (median age: 45 vs. 22 years; p < 0.0001) and had a lower education level (high school and college: 38.1% vs. 100%; p < 0.0001). HCVST usability was high among MSM with fewer observed mistakes, difficulties, or participants requiring assistance (33.7%, 28.8%, and 17.3%, respectively) compared to PWID (62.9%, 53.3%, and 66.7%, respectively; all p < 0.0001)). Inter-reader and inter-operator agreement were good in both groups (Kappa coefficient range: 0.61–0.99). However, the concordance between HCVST and study staff -read or performed HCV testing was lower among PWID than MSM (inter-reader concordance 88.6% vs. 99.0% and inter-operator concordance 81.9% vs. 99%). Overall, HCVST was highly acceptable with moderate to high usability among PWID and MSM in Thai Nguyen. Efforts to provide support and assistance may be needed to optimize performance, particularly for PWID populations and for those who are older and with lower literacy or education levels.
Collapse
|