76
|
Knipfer C, Motz J, Adler W, Brunner K, Gebrekidan MT, Hankel R, Agaimy A, Will S, Braeuer A, Neukam FW, Stelzle F. Erratum: Raman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma: publisher's note. BIOMEDICAL OPTICS EXPRESS 2015; 6:2675. [PMID: 26203390 PMCID: PMC4505718 DOI: 10.1364/boe.6.002675] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Indexed: 03/07/2024]
Abstract
The author list appeared incorrectly in [Biomed. Opt. Express 5(9), 3252-3265 (2014)]. The author names were corrected online as of January 17, 2015: https://www.osapublishing.org/boe/abstract.cfm?uri=boe-5-9-3252.[This corrects the article on p. 3252 in vol. 5, PMID: 25401036.].
Collapse
|
77
|
Le VH, Lee S, Kim B, Yoon Y, Yoon CJ, Chung WK, Kim KH. Correlation between polarization sensitive optical coherence tomography and second harmonic generation microscopy in skin. BIOMEDICAL OPTICS EXPRESS 2015. [PMID: 26203380 PMCID: PMC4505708 DOI: 10.1364/boe.6.002542] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Both polarization sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are 3D optical imaging methods providing information related to collagen in the skin. PS-OCT provides birefringence information which is due to the collagen composition of the skin. SHG microscopy visualizes collagen fibers in the skin based on their SHG property. These two modalities have been applied to the same skin pathologies associated with collagen changes, but their relationship has not been examined. In this study, we tried to find the relationship by imaging the same skin samples with both modalities. Various parts of the normal rat skin and burn damaged skin were imaged ex vivo, and their images were analyzed both qualitatively and quantitatively. PS-OCT images were analyzed to obtain tissue birefringence. SHG images were analyzed to obtain collagen orientation indices by applying 2D Fourier transform. The skin samples having higher birefringence values had higher collagen orientation indices, and a linear correlation was found between them. Burn damaged skin showed decreases in both parameters compared to the control skins. This relationship between the bulk and microscopic properties of skin may be useful for further skin studies.
Collapse
|
78
|
Sheehy CK, Tiruveedhula P, Sabesan R, Roorda A. Active eye-tracking for an adaptive optics scanning laser ophthalmoscope. BIOMEDICAL OPTICS EXPRESS 2015; 6. [PMID: 26203370 PMCID: PMC4505698 DOI: 10.1364/boe.6.002412] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We demonstrate a system that combines a tracking scanning laser ophthalmoscope (TSLO) and an adaptive optics scanning laser ophthalmoscope (AOSLO) system resulting in both optical (hardware) and digital (software) eye-tracking capabilities. The hybrid system employs the TSLO for active eye-tracking at a rate up to 960 Hz for real-time stabilization of the AOSLO system. AOSLO videos with active eye-tracking signals showed, at most, an amplitude of motion of 0.20 arcminutes for horizontal motion and 0.14 arcminutes for vertical motion. Subsequent real-time digital stabilization limited residual motion to an average of only 0.06 arcminutes (a 95% reduction). By correcting for high amplitude, low frequency drifts of the eye, the active TSLO eye-tracking system enabled the AOSLO system to capture high-resolution retinal images over a larger range of motion than previously possible with just the AOSLO imaging system alone.
Collapse
|
79
|
Lee AMD, Cahill L, Liu K, MacAulay C, Poh C, Lane P. Wide-field in vivo oral OCT imaging. BIOMEDICAL OPTICS EXPRESS 2015; 6:2664-74. [PMID: 26203389 PMCID: PMC4505717 DOI: 10.1364/boe.6.002664] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 06/18/2015] [Accepted: 06/19/2015] [Indexed: 05/02/2023]
Abstract
We have built a polarization-sensitive swept source Optical Coherence Tomography (OCT) instrument capable of wide-field in vivo imaging in the oral cavity. This instrument uses a hand-held side-looking fiber-optic rotary pullback catheter that can cover two dimensional tissue imaging fields approximately 2.5 mm wide by up to 90 mm length in a single image acquisition. The catheter spins at 100 Hz with pullback speeds up to 15 mm/s allowing imaging of areas up to 225 mm(2) field-of-view in seconds. A catheter sheath and two optional catheter sheath holders have been designed to allow imaging at all locations within the oral cavity. Image quality of 2-dimensional image slices through the data can be greatly enhanced by averaging over the orthogonal dimension to reduce speckle. Initial in vivo imaging results reveal a wide-field view of features such as epithelial thickness and continuity of the basement membrane that may be useful in clinic for chair-side management of oral lesions.
Collapse
|
80
|
Lee J, Chae Y, Ahn YC, Moon S. Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber. BIOMEDICAL OPTICS EXPRESS 2015; 6:1782-96. [PMID: 26137380 PMCID: PMC4467695 DOI: 10.1364/boe.6.001782] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 04/09/2015] [Accepted: 04/16/2015] [Indexed: 05/18/2023]
Abstract
We present an ultra-thin fiber-body endoscopy probe for optical coherence tomography (OCT) which is based on a stepwise transitional core (STC) fiber. In a minimalistic design, our probe was made of spliced specialty fibers that could be directly used for beam probing optics without using a lens. In our probe, the OCT light delivered through a single-mode fiber was efficiently expanded to a large mode field of 24 μm diameter for a low beam divergence. The size of our probe was 85 μm in the probe's diameter while operated in a 160-μm thick protective tubing. Through theoretical and experimental analyses, our probe was found to exhibit various attractive features in terms of compactness, flexibility and reliability along with its excellent fabrication simplicity.
Collapse
|
81
|
Fu X, Patel D, Zhu H, MacLennan G, Wang YT, Jenkins MW, Rollins AM. Miniature forward-viewing common-path OCT probe for imaging the renal pelvis. BIOMEDICAL OPTICS EXPRESS 2015; 6:1164-71. [PMID: 25909002 PMCID: PMC4399657 DOI: 10.1364/boe.6.001164] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 02/27/2015] [Accepted: 03/02/2015] [Indexed: 05/08/2023]
Abstract
We demonstrate an ultrathin flexible cone-scanning forward-viewing OCT probe which can fit through the working channel of a flexible ureteroscope for renal pelvis imaging. The probe is fabricated by splicing a 200 µm section of core-less fiber and a 150 µm section of gradient-index (GRIN) fiber to the end of a single mode (SM) fiber. The probe is designed for common-path OCT imaging where the back-reflection of the GRIN fiber/air interface is used as the reference signal. Optimum sensitivity was achieved with a 2 degree polished probe tip. A correlation algorithm was used to correct image distortion caused by non-uniform rotation of the probe. The probe is demonstrated by imaging human skin in vivo and porcine renal pelvis ex vivo and is suitable for imaging the renal pelvis in vivo for cancer staging.
Collapse
|
82
|
Beaudette K, Baac HW, Madore WJ, Villiger M, Godbout N, Bouma BE, Boudoux C. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler. BIOMEDICAL OPTICS EXPRESS 2015; 6:1293-303. [PMID: 25909013 PMCID: PMC4399668 DOI: 10.1364/boe.6.001293] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 03/06/2015] [Accepted: 03/10/2015] [Indexed: 05/05/2023]
Abstract
Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.
Collapse
|
83
|
Spether D, Scharpf M, Hennenlotter J, Schwentner C, Neugebauer A, Nüßle D, Fischer K, Zappe H, Stenzl A, Fend F, Seifert A, Enderle M. Real-time tissue differentiation based on optical emission spectroscopy for guided electrosurgical tumor resection. BIOMEDICAL OPTICS EXPRESS 2015; 6:1419-1428. [PMID: 25909025 PMCID: PMC4399680 DOI: 10.1364/boe.6.001419] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 01/31/2015] [Accepted: 01/31/2015] [Indexed: 06/04/2023]
Abstract
Complete surgical removal of cancer tissue with effective preservation of healthy tissue is one of the most important challenges in modern oncology. We present a method for real-time, in situ differentiation of tissue based on optical emission spectroscopy (OES) performed during electrosurgery not requiring any biomarkers, additional light sources or other excitation processes. The analysis of the optical emission spectra, enables the differentiation of healthy and tumorous tissue. By using multi-class support vector machine (SVM) algorithms, distinguishing between tumor types also seems to be possible. Due to its fast reaction time (0.05s) the method can be used for real-time navigation helping the surgeon achieve complete resection. The system's easy realization has been proven by successful integration in a commercial electro surgical unit (ESU). In a first step the method was verified by using ex vivo tissue samples. The histological analysis confirmed, 95% of correctly classified tissue types.
Collapse
|
84
|
Felberer F, Rechenmacher M, Haindl R, Baumann B, Hitzenberger CK, Pircher M. Imaging of retinal vasculature using adaptive optics SLO/OCT. BIOMEDICAL OPTICS EXPRESS 2015; 6:1407-18. [PMID: 25909024 PMCID: PMC4399679 DOI: 10.1364/boe.6.001407] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 03/16/2015] [Accepted: 03/18/2015] [Indexed: 05/18/2023]
Abstract
We use our previously developed adaptive optics (AO) scanning laser ophthalmoscope (SLO)/ optical coherence tomography (OCT) instrument to investigate its capability for imaging retinal vasculature. The system records SLO and OCT images simultaneously with a pixel to pixel correspondence which allows a direct comparison between those imaging modalities. Different field of views ranging from 0.8°x0.8° up to 4°x4° are supported by the instrument. In addition a dynamic focus scheme was developed for the AO-SLO/OCT system in order to maintain the high transverse resolution throughout imaging depth. The active axial eye tracking that is implemented in the OCT channel allows time resolved measurements of the retinal vasculature in the en-face imaging plane. Vessel walls and structures that we believe correspond to individual erythrocytes could be visualized with the system.
Collapse
|
85
|
Chen Y, Liu JT. Characterizing the beam steering and distortion of Gaussian and Bessel beams focused in tissues with microscopic heterogeneities. BIOMEDICAL OPTICS EXPRESS 2015; 6:1318-30. [PMID: 25909015 PMCID: PMC4399670 DOI: 10.1364/boe.6.001318] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2015] [Revised: 03/11/2015] [Accepted: 03/12/2015] [Indexed: 05/07/2023]
Abstract
Bessel beams have recently been investigated as a means of improving deep-tissue microscopy in highly scattering and heterogeneous media. It has been suggested that the long depth-of-field and self-reconstructing property of a Bessel beam enables an increased penetration depth of the focused beam in tissues compared to a conventional Gaussian beam. However, a study is needed to better quantify the magnitude of the beam steering as well as the distortion of focused Gaussian and Bessel beams in tissues with microscopic heterogeneities. Here, we have developed an imaging method and quantitative metrics to evaluate the motion and distortion of low-numerical-aperture (NA) Gaussian and Bessel beams focused in water, heterogeneous phantoms, and fresh mouse esophagus tissues. Our results indicate that low-NA Bessel beams exhibit reduced beam-steering artifacts and distortions compared to Gaussian beams, and are therefore potentially useful for microscopy applications in which pointing accuracy and beam quality are critical, such as dual-axis confocal (DAC) microscopy.
Collapse
|
86
|
Arifler D, Zhu T, Madaan S, Tachtsidis I. Optimal wavelength combinations for near-infrared spectroscopic monitoring of changes in brain tissue hemoglobin and cytochrome c oxidase concentrations. BIOMEDICAL OPTICS EXPRESS 2015; 6:933-47. [PMID: 25798316 PMCID: PMC4361446 DOI: 10.1364/boe.6.000933] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 02/09/2015] [Accepted: 02/11/2015] [Indexed: 05/19/2023]
Abstract
We analyze broadband near-infrared spectroscopic measurements obtained from newborn piglets subjected to hypoxia-ischemia and we aim to identify optimal wavelength combinations for monitoring cerebral tissue chromophores. We implement an optimization routine based on the genetic algorithm to perform a heuristic search for discrete wavelength combinations that can provide accurate concentration information when benchmarked against the gold standard of 121 wavelengths. The results indicate that it is possible to significantly reduce the number of measurement wavelengths used in conjunction with spectroscopic algorithms and still achieve a high performance in estimating changes in concentrations of oxyhemoglobin, deoxyhemoglobin, and oxidized cytochrome c oxidase. While the use of a 3-wavelength combination leads to mean recovery errors of up to 10%, these errors drop to less than 4% with 4 or 5 wavelengths and to even less than 2% with 8 wavelengths.
Collapse
|
87
|
Yang JM, Li C, Chen R, Rao B, Yao J, Yeh CH, Danielli A, Maslov K, Zhou Q, Shung KK, Wang LV. Optical-resolution photoacoustic endomicroscopy in vivo. BIOMEDICAL OPTICS EXPRESS 2015; 6:918-32. [PMID: 25798315 PMCID: PMC4361445 DOI: 10.1364/boe.6.000918] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 01/26/2015] [Accepted: 01/28/2015] [Indexed: 05/03/2023]
Abstract
Optical-resolution photoacoustic microscopy (OR-PAM) has become a major experimental tool of photoacoustic tomography, with unique imaging capabilities for various biological applications. However, conventional imaging systems are all table-top embodiments, which preclude their use in internal organs. In this study, by applying the OR-PAM concept to our recently developed endoscopic technique, called photoacoustic endoscopy (PAE), we created an optical-resolution photoacoustic endomicroscopy (OR-PAEM) system, which enables internal organ imaging with a much finer resolution than conventional acoustic-resolution PAE systems. OR-PAEM has potential preclinical and clinical applications using either endogenous or exogenous contrast agents.
Collapse
|
88
|
Yoon Y, Jang WH, Xiao P, Kim B, Wang T, Li Q, Lee JY, Chung E, Kim KH. In vivo wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography of human oral cavity with a forward-viewing probe. BIOMEDICAL OPTICS EXPRESS 2015; 6:524-35. [PMID: 25780742 PMCID: PMC4354576 DOI: 10.1364/boe.6.000524] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Revised: 12/31/2014] [Accepted: 01/07/2015] [Indexed: 05/18/2023]
Abstract
We report multimodal imaging of human oral cavity in vivo based on simultaneous wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography (PS-OCT) with a forward-viewing imaging probe. Wide-field reflectance/fluorescence imaging and PS-OCT were to provide both morphological and fluorescence information on the surface, and structural and birefringent information below the surface respectively. The forward-viewing probe was designed to access the oral cavity through the mouth with dimensions of approximately 10 mm in diameter and 180 mm in length. The probe had field of view (FOV) of approximately 5.5 mm in diameter, and adjustable depth of field (DOF) from 2 mm to 10 mm by controlling numerical aperture (NA) in the detection path. This adjustable DOF was to accommodate both requirements for image-based guiding with high DOF and high-resolution, high-sensitivity imaging with low DOF. This multimodal imaging system was characterized by using a tissue phantom and a mouse model in vivo, and was applied to human oral cavity. Information of surface morphology and vasculature, and under-surface layered structure and birefringence of the oral cavity tissues was obtained. These results showed feasibility of this multimodal imaging system as a tool for studying oral cavity lesions in clinical applications.
Collapse
|
89
|
Lagarto J, Dyer BT, Talbot C, Sikkel MB, Peters NS, French PMW, Lyon AR, Dunsby C. Application of time-resolved autofluorescence to label-free in vivo optical mapping of changes in tissue matrix and metabolism associated with myocardial infarction and heart failure. BIOMEDICAL OPTICS EXPRESS 2015; 6:324-46. [PMID: 25780727 PMCID: PMC4354591 DOI: 10.1364/boe.6.000324] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 10/17/2014] [Accepted: 10/21/2014] [Indexed: 05/03/2023]
Abstract
We investigate the potential of an instrument combining time-resolved spectrofluorometry and diffuse reflectance spectroscopy to measure structural and metabolic changes in cardiac tissue in vivo in a 16 week post-myocardial infarction heart failure model in rats. In the scar region, we observed changes in the fluorescence signal that can be explained by increased collagen content, which is in good agreement with histology. In areas remote from the scar tissue, we measured changes in the fluorescence signal (p < 0.001) that cannot be explained by differences in collagen content and we attribute this to altered metabolism within the myocardium. A linear discriminant analysis algorithm was applied to the measurements to predict the tissue disease state. When we combine all measurements, our results reveal high diagnostic accuracy in the infarcted area (100%) and border zone (94.44%) as well as in remote regions from the scar (> 77%). Overall, our results demonstrate the potential of our instrument to characterize structural and metabolic changes in a failing heart in vivo without using exogenous labels.
Collapse
|
90
|
Kang D, Huang Q, Li Y. Noninvasive photoacoustic measurement of the composite indicator dilution curve for cardiac output estimation. BIOMEDICAL OPTICS EXPRESS 2015; 6:536-543. [PMID: 25780743 PMCID: PMC4354579 DOI: 10.1364/boe.6.000536] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 01/06/2015] [Accepted: 01/09/2015] [Indexed: 06/04/2023]
Abstract
Recently, the measurement of indicator dilution curves using a photoacoustic (PA) technology was reported, which showed promising results on the noninvasive estimation of cardiac output (CO) that is an important hemodynamic parameter useful in various clinical situations. However, in clinical practice, measuring PA indicator dilution curves from an arterial blood vessel requires an ultrasound transducer array capable of focusing on the targeted artery. This causes several challenges on the clinical translation of the PA indicator dilution method, such as high sensor cost and complexity. In this paper, we theoretically derived that a composite PA indicator dilution curve simultaneously measured from both arterial and venous blood vessels can be used to estimate CO correctly. The ex-vivo and in-vivo experimental results with a flat ultrasound transducer verified the developed theory. We believe this new concept would overcome the main challenges on the clinical translation of the noninvasive PA indicator dilution technology.
Collapse
|
91
|
Kuo JR, Lin SS, Liu J, Chen SH, Chio CC, Wang JJ, Liu JM. Deep brain light stimulation effects on glutamate and dopamine concentration. BIOMEDICAL OPTICS EXPRESS 2015; 6:23-31. [PMID: 25657871 PMCID: PMC4317125 DOI: 10.1364/boe.6.000023] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Revised: 11/12/2014] [Accepted: 11/14/2014] [Indexed: 06/04/2023]
Abstract
Compared to deep brain electrical stimulation, which has been applied to treating pathological brain diseases, little work has been done on the effect of deep brain light stimulation. A fiber-coupled laser stimulator at 840 nm wavelength and 130 Hz pulse repetition rate is developed in this work for deep brain light stimulation in a rat model. Concentration changes in glutamate and dopamine in the striatum are observed using a microdialysis probe when the subthalamic nucleus (STN) is stimulated at various optical power levels. Experimental results show that light stimulation causes the concentration of glutamate to decrease while that of dopamine is increased. This suggests that deep brain light stimulation of the STN is a promising therapeutic strategy for dopamine-related diseases such as Parkinson's disease. The stimulator developed for this work is useful for deep brain light stimulation in biomedical research.
Collapse
|
92
|
Kim M, Kang D, Wu T, Tabatabaei N, Carruth RW, Martinez RV, Whitesides GM, Nakajima Y, Tearney GJ. Miniature objective lens with variable focus for confocal endomicroscopy. BIOMEDICAL OPTICS EXPRESS 2014; 5:4350-61. [PMID: 25574443 PMCID: PMC4285610 DOI: 10.1364/boe.5.004350] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Revised: 11/19/2014] [Accepted: 11/19/2014] [Indexed: 05/05/2023]
Abstract
Spectrally encoded confocal microscopy (SECM) is a reflectance confocal microscopy technology that can rapidly image large areas of luminal organs at microscopic resolution. One of the main challenges for large-area SECM imaging in vivo is maintaining the same imaging depth within the tissue when patient motion and tissue surface irregularity are present. In this paper, we report the development of a miniature vari-focal objective lens that can be used in an SECM endoscopic probe to conduct adaptive focusing and to maintain the same imaging depth during in vivo imaging. The vari-focal objective lens is composed of an aspheric singlet with an NA of 0.5, a miniature water chamber, and a thin elastic membrane. The water volume within the chamber was changed to control curvature of the elastic membrane, which subsequently altered the position of the SECM focus. The vari-focal objective lens has a diameter of 5 mm and thickness of 4 mm. A vari-focal range of 240 μm was achieved while maintaining lateral resolution better than 2.6 μm and axial resolution better than 26 μm. Volumetric SECM images of swine esophageal tissues were obtained over the vari-focal range of 260 μm. SECM images clearly visualized cellular features of the swine esophagus at all focal depths, including basal cell nuclei, papillae, and lamina propria.
Collapse
|
93
|
Tsiminis G, Klarić TS, Schartner EP, Warren-Smith SC, Lewis MD, Koblar SA, Monro TM. Generating and measuring photochemical changes inside the brain using optical fibers: exploring stroke. BIOMEDICAL OPTICS EXPRESS 2014; 5:3975-3980. [PMID: 25426323 PMCID: PMC4242031 DOI: 10.1364/boe.5.003975] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 10/09/2014] [Accepted: 10/09/2014] [Indexed: 06/04/2023]
Abstract
We report here on the development of a method for inducing a stroke in a specific location within a mouse brain through the use of an optical fiber. By capturing the emitted fluorescence signal generated using the same fiber it is possible to monitor photochemical changes within the brain in real-time, and directly measure the concentration of the stroke-inducing dye, Rose Bengal, at the infarct site. This technique reduces the requirement for post-operative histology to determine if a stroke has successfully been induced within the animal, and therefore opens up the opportunity to explore the recovery of the brain after the stroke event.
Collapse
|
94
|
Bale G, Mitra S, Meek J, Robertson N, Tachtsidis I. A new broadband near-infrared spectroscopy system for in-vivo measurements of cerebral cytochrome-c-oxidase changes in neonatal brain injury. BIOMEDICAL OPTICS EXPRESS 2014; 5:3450-66. [PMID: 25360364 PMCID: PMC4206316 DOI: 10.1364/boe.5.003450] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/15/2014] [Accepted: 08/22/2014] [Indexed: 05/02/2023]
Abstract
We present a novel lens-based broadband near-infrared spectroscopy system to simultaneously measure cerebral changes in tissue oxygenation and haemodynamics via estimation of the changes in haemoglobin concentration; in addition to oxygen utilization via the measurement of the oxidation state of cytochrome-c-oxidase (CCO). We demonstrate the use of the system in a cohort of 6 newborn infants with neonatal encephalopathy in the Neonatal Intensive Care Unit for continuous measurement periods of up to 5 days. NIRS data was collected from above the frontal lobe on the left and right hemispheres simultaneously with systemic data to allow multimodal data analysis. This allowed us to study the NIRS variables in response to global pathophysiological events and we focused our analysis to spontaneous oxygen desaturations. We identified changes from the NIRS variables during 236 oxygen desaturations from over 212 hours of data with a change from the baseline to nadir of -12 ± 3%. There was a consistent negative change in the Δ[HbD] (= oxygenated - deoxygenated haemoglobin) and Δ[oxCCO] measurements, mean decreases were 3.0 ± 1.7μM and 0.22 ± 0.11μM, and a positive change in the Δ[HbT] (= oxygenated + deoxygenated haemoglobin) measurements across all subjects, mean increase was 0.85 ± 0.58μM. We have shown with a feasibility study that the relationship between haemoglobin oxygenation changes and CCO oxidation changes during these desaturation events was significantly associated with a magnetic resonance spectroscopy (MRS)-measured biomarker of injury severity (r = 0.91, p<0.01).
Collapse
|
95
|
Gunadi S, Leung TS, Elwell CE, Tachtsidis I. Spatial sensitivity and penetration depth of three cerebral oxygenation monitors. BIOMEDICAL OPTICS EXPRESS 2014; 5:2896-912. [PMID: 25401006 PMCID: PMC4230856 DOI: 10.1364/boe.5.002896] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 07/16/2014] [Accepted: 07/16/2014] [Indexed: 05/03/2023]
Abstract
The spatial sensitivities of NIRO-100, ISS Oximeter and TRS-20 cerebral oxygenation monitors are mapped using the local perturbation method to inform on their penetration depths and susceptibilities to superficial contaminations. The results show that TRS-20 has the deepest mean penetration depth and is less sensitive than the other monitors to a localized absorption change in the superficial layer. However, an integration time of more than five seconds is required by the TRS-20 to achieve an acceptable level of signal-to-noise ratio, which is the poorest amongst the monitors. With the exception of NIRO-100 continuous wave method, the monitors are not significantly responsive to layer-wide absorption change that occurs in the superficial layer.
Collapse
|
96
|
Christian K, Johanna M, Werner A, Kathrin B, Tesfay GM, Robert H, Abbas A, Stefan W, Andreas B, Wilhelm NF, Florian S. Raman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma. BIOMEDICAL OPTICS EXPRESS 2014; 5:3252-65. [PMID: 25401036 PMCID: PMC4230857 DOI: 10.1364/boe.5.003252] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Revised: 07/16/2014] [Accepted: 07/31/2014] [Indexed: 05/04/2023]
Abstract
The feasibility of shifted-excitation Raman difference spectroscopy (SERDS) as a label-free and non-invasive technique for an objective diagnosis of oral cancer (OSCC) was investigated by analyzing 12 ex vivo OSCC samples. 72 mean SERDS spectra from each three physiological tissue points and pathological lesions were correlated with the histo-pathological diagnosis. Principal component analysis (PCA) and linear discriminant analysis (LDA) showed excellent results with an area under the curve of 94.5% and a classification error of 9.7% (sensitivity: 86.1%; specificity: 94.4%). The SERDS Raman spectra of malignant and benignant tissues were discriminable with respect to the spectral features of proteins, lipids and nucleic acids. The presented method is capable of a highly accurate identification of OSCC. These findings suggest a high validity and reproducibility of SERDS combined with PCA and LDA analysis regarding oral cancer tissue.
Collapse
|
97
|
Pahlevaninezhad H, Lee AMD, Shaipanich T, Raizada R, Cahill L, Hohert G, Yang VXD, Lam S, MacAulay C, Lane P. A high-efficiency fiber-based imaging system for co-registered autofluorescence and optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:2978-87. [PMID: 25401011 PMCID: PMC4230860 DOI: 10.1364/boe.5.002978] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 07/31/2014] [Accepted: 08/01/2014] [Indexed: 05/06/2023]
Abstract
We present a power-efficient fiber-based imaging system capable of co-registered autofluorescence imaging and optical coherence tomography (AF/OCT). The system employs a custom fiber optic rotary joint (FORJ) with an embedded dichroic mirror to efficiently combine the OCT and AF pathways. This three-port wavelength multiplexing FORJ setup has a throughput of more than 83% for collected AF emission, significantly more efficient compared to previously reported fiber-based methods. A custom 900 µm diameter catheter ‒ consisting of a rotating lens assembly, double-clad fiber (DCF), and torque cable in a stationary plastic tube ‒ was fabricated to allow AF/OCT imaging of small airways in vivo. We demonstrate the performance of this system ex vivo in resected porcine airway specimens and in vivo in human on fingers, in the oral cavity, and in peripheral airways.
Collapse
|
98
|
Pires L, Nogueira MS, Pratavieira S, Moriyama LT, Kurachi C. Time-resolved fluorescence lifetime for cutaneous melanoma detection. BIOMEDICAL OPTICS EXPRESS 2014; 5:3080-9. [PMID: 25401022 PMCID: PMC4230861 DOI: 10.1364/boe.5.003080] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 08/08/2014] [Accepted: 08/10/2014] [Indexed: 05/04/2023]
Abstract
Melanoma is the most aggressive skin cancer type. It is characterized by pigmented lesions with high tissue invasion and metastatic potential. The early detection of melanoma is extremely important to improve patient prognosis and survival rate, since it can progress to the deadly metastatic stage. Presently, the melanoma diagnosis is based on the clinical analysis of the macroscopic lesion characteristics such as shape, color, borders following the ABCD rules. The aim of this study is to evaluate the time-resolved fluorescence lifetime of NADH and FAD molecules to detect cutaneous melanoma in an experimental in vivo model. Forty-two lesions were analyzed and the data was classified using linear discriminant analysis, a sensitivity of 99.4%, specificity of 97.4% and accuracy of 98.4% were achieved. These results show the potential of this fluorescence spectroscopy for melanoma detection.
Collapse
|
99
|
Binzoni T, Torricelli A, Giust R, Sanguinetti B, Bernhard P, Spinelli L. Bone tissue phantoms for optical flowmeters at large interoptode spacing generated by 3D-stereolithography. BIOMEDICAL OPTICS EXPRESS 2014; 5:2715-25. [PMID: 25136496 PMCID: PMC4133000 DOI: 10.1364/boe.5.002715] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Revised: 06/30/2014] [Accepted: 07/12/2014] [Indexed: 05/23/2023]
Abstract
A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of any geometrical shape can be conceived. Absorption coefficient, reduced scattering coefficient and refractive index of the optical phantom have been measured to ensure that the optical parameters reasonably reproduce real human bone tissue in vivo. An experimental demonstration of a possible use of the optical phantom, utilizing a laser-Doppler flowmeter, is also presented.
Collapse
|
100
|
Chen Z, Zhu N, Pacheco S, Wang X, Liang R. Single camera imaging system for color and near-infrared fluorescence image guided surgery. BIOMEDICAL OPTICS EXPRESS 2014; 5:2791-7. [PMID: 25136502 PMCID: PMC4133006 DOI: 10.1364/boe.5.002791] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 07/17/2014] [Accepted: 07/19/2014] [Indexed: 05/05/2023]
Abstract
Near-infrared (NIR) fluorescence imaging systems have been developed for image guided surgery in recent years. However, current systems are typically bulky and work only when surgical light in the operating room (OR) is off. We propose a single camera imaging system that is capable of capturing NIR fluorescence and color images under normal surgical lighting illumination. Using a new RGB-NIR sensor and synchronized NIR excitation illumination, we have demonstrated that the system can acquire both color information and fluorescence signal with high sensitivity under normal surgical lighting illumination. The experimental results show that ICG sample with concentration of 0.13 μM can be detected when the excitation irradiance is 3.92 mW/cm(2) at an exposure time of 10 ms.
Collapse
|