76
|
Bosso G, Sansone G, Papillo M, Giaquinto A, Orefice S, Allegorico E, Serra C, Minerva V, Mercurio V, Cannavacciuolo F, Dello Vicario F, Porta G, Pagano A, Numis FG. Lung ultrasound-guided PEEP titration in COVID-19 patients treated with CPAP. J Basic Clin Physiol Pharmacol 2023; 34:677-682. [PMID: 37463298 DOI: 10.1515/jbcpp-2023-0165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 07/06/2023] [Indexed: 07/20/2023]
Abstract
OBJECTIVES An increasing number of COVID-19 patients were treated with continuous positive airways pressure (CPAP). To evaluate the clinical effects of personalized positive end-expiratory pressure (PEEP) compared to standard fixed PEEP in COVID-19 patients requiring CPAP. METHODS This is a single center, prospective, randomized clinical study. Sixty-three COVID-19 patients with hypoxemic respiratory failure and bilateral pneumonia were randomized in two Groups: Group A received CPAP with fixed PEEP of 10 cm H2O, Group B performed the "PEEP trial", that consists in the evaluation of best PEEP defined as the PEEP value that precedes the echographic appearance of "lung pulse" determining a PaO2/FiO2 increase. Primary outcome was composite in-hospital mortality + intubation, secondary outcome was the percentage increase of PaO2/FiO2. As safety indicator, the incidence of pneumothorax was collected. RESULTS Thirty-two patients were enrolled in Group A and 31 in Group B. The two groups were comparable for clinical characteristics and laboratory parameters. The primary outcome occurred in 36 (57.1 %) patients: 23 (71.8 %) in Group A and 13 (41.9 %) in Group B (p<0.01). Mortality was higher in Group A (53.1 vs. 19.3 %, p<0.01), while intubation rate was comparable between groups. Group B showed a higher PaO2/FiO2 increase than Group A (34.9 vs. 13.1 %, p<0.01). Five cases of pneumothorax were reported in Group A, none in Group B. CONCLUSIONS Lung ultrasound-guided PEEP trial is associated with lower mortality in COVID-19 patients treated with CPAP. Identifying the best PEEP is useful to increase oxygenation and reduce the incidence of complications.
Collapse
|
77
|
Landry SA, Mann DL, Beare R, McIntyre R, Beatty C, Thomson LDJ, Collet J, Joosten SA, Hamilton GS, Edwards BA. Oronasal vs Nasal Masks: The Impact of Mask Type on CPAP Requirement, Pharyngeal Critical Closing Pressure (P crit), and Upper Airway Cross-Sectional Areas in Patients With OSA. Chest 2023; 164:747-756. [PMID: 36990149 DOI: 10.1016/j.chest.2023.03.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 03/08/2023] [Accepted: 03/15/2023] [Indexed: 03/28/2023] Open
Abstract
BACKGROUND CPAP delivered via an oronasal mask is associated with lower adherence, higher residual apnea-hypopnea index (AHI), and increased CPAP therapeutic pressure compared with nasal masks. However, the mechanisms underlying the increased pressure requirements are not well understood. RESEARCH QUESTION How do oronasal masks affect upper airway anatomy and collapsibility? STUDY DESIGN AND METHODS Fourteen patients with OSA underwent a sleep study with both a nasal and oronasal mask, each for one-half of the night (order randomized). CPAP was manually titrated to determine therapeutic pressure. Upper airway collapsibility was assessed using the pharyngeal critical closing pressure (Pcrit) technique. Cine MRI was done to dynamically assess the cross-sectional area of the retroglossal and retropalatal airway throughout the respiratory cycle with each mask interface. Scans were repeated at 4 cm H2O and at the nasal and oronasal therapeutic pressures. RESULTS The oronasal mask was associated with higher therapeutic pressure requirements (ΔM ± SEM; +2.6 ± 0.5; P < .001) and higher Pcrit (+2.4 ± 0.5 cm H2O; P = .001) compared with the nasal mask. The change in therapeutic pressure between masks was strongly correlated with the change in Pcrit (r2 = 0.73; P = .003). Increasing CPAP increased both the retroglossal and retropalatal airway dimensions across both masks. After controlling for pressure and breath phase, the retropalatal cross-sectional area was moderately larger when using a nasal vs an oronasal mask (+17.2 mm2; 95% CI, 6.2-28.2, P < .001) while nasal breathing. INTERPRETATION Oronasal masks are associated with a more collapsible airway than nasal masks, which likely contributes to the need for a higher therapeutic pressure.
Collapse
|
78
|
Puxty KA, Blayney M, Kaye C, McPeake J, Stewart N, Paton M, Hall R, Donaldson L, Lone N. Use of protracted CPAP as supportive treatment for COVID-19 pneumonitis and associated outcomes: a national cohort study. Br J Anaesth 2023; 131:617-625. [PMID: 37349238 PMCID: PMC10209449 DOI: 10.1016/j.bja.2023.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 05/15/2023] [Accepted: 05/18/2023] [Indexed: 06/24/2023] Open
Abstract
BACKGROUND Continuous positive airway pressure (CPAP) has been increasingly deployed to manage patients with COVID-19 and acute respiratory failure, often for protracted periods. However, concerns about protracted CPAP have been raised. This study aimed to examine the use of CPAP for patients with COVID-19 and the outcomes after protracted use. METHODS This was a national cohort study of all adults admitted to Scottish critical care units with COVID-19 from March 1, 2020 to December 25, 2021 who received CPAP. Protracted CPAP was defined as ≥ 5 continuous days of CPAP. Outcomes included CPAP failure rate (institution of invasive mechanical ventilation [IMV] or death), mortality, and outcomes after institution of IMV. Multivariable logistic regression was performed to assess the impact of protracted CPAP on mortality after IMV. RESULTS A total of 1961 patients with COVID-19 received CPAP for COVID-19 pneumonitis, with 733 patients (37.4%) receiving protracted CPAP. CPAP failure occurred in 891 (45.4%): 544 patients (27.7%) received IMV and 347 patients (17.7%) died in critical care without IMV. Hospital mortality rate was 41.3% for the population. For patients who subsequently commenced IMV, hospital mortality was 58.7% for the standard duration CPAP group and 73.9% for the protracted duration CPAP group (P=0.003); however, there was no statistical difference in hospital mortality after adjustment for confounders (odds ratio 1.4, 95% confidence interval 0.84-2.33, P=0.195). CONCLUSIONS Protracted CPAP was used frequently for managing patients with COVID-19. Whilst it was not associated with worse outcomes for those patients who subsequently required IMV, this might be due to residual confounding and differences in processes of care.
Collapse
|
79
|
Zabara-Antal A, Grosu-Creanga I, Zabara ML, Cernomaz AT, Ciuntu BM, Melinte O, Lupascu C, Trofor AC. A Debate on Surgical and Nonsurgical Approaches for Obstructive Sleep Apnea: A Comprehensive Review. J Pers Med 2023; 13:1288. [PMID: 37763056 PMCID: PMC10533009 DOI: 10.3390/jpm13091288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 08/17/2023] [Accepted: 08/21/2023] [Indexed: 09/29/2023] Open
Abstract
Regular and unobstructed breathing during the night is the prerequisite for an undisturbed and restful sleep. The most prevalent nocturnal breathing disturbance with morbid consequences is obstructive sleep apnea syndrome. The prevalence of obstructive sleep apnea (OSA) is increasing, and a significant number of patients with OSA are undiagnosed. On the other hand, the "obesity epidemic" is a growing concern globally. A sleep test is required to diagnose sleep apnea and to individualize therapy. A multidisciplinary approach is the key to success. This narrative review presents a debate on whether surgery is a friend or a foe in the treatment of sleep apnea. Depending on the type and severity of the apnea, the causal factor, and the presence of obesity and hypercapnia as well as the associated pathologies, the optimal therapeutic method is determined for each individual case. The article concludes that each case is unique, and there is no ideal method. Positive pressure ventilation, although a therapeutic gold standard, has its disadvantages extensively discussed in this paper. Nevertheless, it is necessary prior to any surgical intervention, either for the curative treatment of the causal factor of apnea or for elective surgery for another condition. The anesthetic risks associated with the presence of apnea and obesity should not be neglected and should form the basis for decision making regarding surgical interventions for the treatment of sleep apnea.
Collapse
|
80
|
Truitt BA, Kallam EF, Price EW, Shah AS, Simon DM, Kasi AS. Outpatient Utilization of the RAM Cannula for Nasal Noninvasive Ventilation in Children. Clin Med Insights Pediatr 2023; 17:11795565231192965. [PMID: 37600750 PMCID: PMC10439674 DOI: 10.1177/11795565231192965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 07/20/2023] [Indexed: 08/22/2023] Open
Abstract
Background The RAM cannula® consists of nasal prongs that can be used to administer oxygen, continuous, and bilevel positive airway pressure therapies. Studies have reported the efficacy and utility of the RAM cannula in inpatients requiring noninvasive ventilation (NIV); however, there is limited literature on the use of the RAM cannula to provide NIV in the outpatient setting. Objectives This study aimed to describe the clinical features and outcomes of children who used NIV via RAM cannula in the outpatient setting. Design Retrospective review. Methods We conducted a retrospective review of children treated with outpatient NIV via RAM cannula at our institution between January 2010 and March 2023. The analyzed data included age, diagnoses, indications for NIV, duration of RAM cannula use, complications, and outcomes at 6 months. Results We identified 20 patients who used outpatient NIV via RAM cannula during the study period. The median age at initiation of NIV via RAM cannula was 5.8 months (IQR 2.4-9.9 months). Indications for NIV included sleep-related hypoventilation (15%), restrictive lung disease (25%), obstructive sleep apnea (45%), and chronic respiratory failure (50%), with 6 patients having ⩾2 indications for NIV. RAM cannula was utilized for inability to tolerate conventional NIV interfaces (80%), to alleviate dyspnea (60%), and to avoid tracheostomy (55%). Patients used NIV via RAM cannula for a median duration of 7.7 months (IQR 3.7-20.6 months). Patient outcomes included ongoing usage of RAM cannula (55%), changing to conventional NIV interfaces (15%) or oxygen (10%), weaning off respiratory support (5%), and death (15%). There were no complications related to using the RAM cannula. Conclusion Our study demonstrates the utility of outpatient NIV via RAM cannula in children with a variety of diagnoses until clinical improvement or tolerance of conventional interfaces, and for avoidance of tracheostomy.
Collapse
|
81
|
Littlejohns A, Please H, Musasizi R, Murdoch S, Nampiina G, Waters I, Birch WD, de Boer G, Kapur N, Ambrozi T, Carol N, Noel N, Parmar J, Culmer P, Lawton T, Namulema E. Descriptive account of the first use of the LeVe CPAP System, a new frugal CPAP System, in adult patients with COVID-19 Pneumonitis in Uganda. Trop Med Health 2023; 51:42. [PMID: 37545001 PMCID: PMC10405477 DOI: 10.1186/s41182-023-00533-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Accepted: 07/27/2023] [Indexed: 08/08/2023] Open
Abstract
BACKGROUND Continuous positive airway pressure (CPAP) has been a key treatment modality for Coronavirus Disease 2019 (COVID-19) worldwide. Globally, the demand for CPAP outstripped the supply during the pandemic. The LeVe CPAP System was developed to provide respiratory support for treatment of COVID-19 and tailored for use in low- and middle-income country (LMIC) settings. Prior to formal trial approval, received in November 2021, these devices were used in extremis to support critically unwell adult patients requiring non-invasive ventilatory support. METHODS This is a retrospective descriptive review of adult patients with COVID-19 pneumonitis, who were treated with advanced respiratory support (CPAP and/or high-flow nasal oxygen, HFNO) at Mengo Hospital, Uganda. Patients were treated with the LeVe CPAP System, Elisa CPAP and/or AIRVO™ HFNO. Treatment was escalated per standard local protocols for respiratory failure, and CPAP was the maximum respiratory support available. Data were collected on patient characteristics, length of time of treatment, clinical outcome, and any adverse events. RESULTS Overall 333 patients were identified as COVID-19 positive, 44 received CPAP ± HFNO of which 43 were included in the study. The median age was 58 years (range 28-91 years) and 58% were female. The median duration of advanced respiratory support was 7 days (range 1-18 days). Overall (all device) mortality was 49% and this was similar between those started on the LeVe CPAP System and those started non-LeVe CPAP System devices (50% vs 47%). CONCLUSIONS The LeVe CPAP system was the most used CPAP device during the pandemic, bringing the hospital's number of available HFNO/CPAP devices from two to 14. They were a critical resource for providing respiratory support to the sickest group of patients when no alternative devices were available. The devices appear to be safe and well-tolerated with no serious adverse events recorded. This study is unable to assess the efficacy of the LeVe CPAP System; therefore, formal comparative studies are required to inform further use.
Collapse
|
82
|
Jaffuel D, Mallet JP, Sabil A. Accuracy of continuous positive airway pressure devices: the devil is in the details, the best is yet to come. Sleep Breath 2023; 27:1651-1654. [PMID: 36394693 DOI: 10.1007/s11325-022-02741-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 10/29/2022] [Accepted: 11/04/2022] [Indexed: 11/18/2022]
|
83
|
Hosseini H, Homayouni-Tabrizi M, Amiri H, Safari-Faramani R, Moradi MT, Fadaei R, Khazaie H. The effect of continuous positive airway pressure on total antioxidant capacity in obstructive sleep apnea: a systematic review and meta-analysis. Sleep Breath 2023; 27:1237-1245. [PMID: 36322225 DOI: 10.1007/s11325-022-02733-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 10/17/2022] [Accepted: 10/20/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND Obstructive sleep apnea (OSA), a sleep-related disorder with high prevalence, is associated with an imbalance in oxidative stress and is linked to cardiovascular disease. There are conflicting reports regarding the effectiveness of continuous positive airway pressure (CPAP) therapy on oxidative stress/antioxidant markers in patients with OSA. This review was performed to evaluate the influence of therapy with CPAP on serum/plasma total antioxidant capacity (TAC) in patients with OSA. METHODS The Cochrane Library, Web of Science, Scopus, Embase, and PubMed were searched through June 2022 to obtain studies evaluating CPAP treatment on TAC in patients with OSA. Overall results were tested using standardized mean difference (SMD) with a 95% confidence interval (CI). Comprehensive Meta-Analysis V2 software was employed to perform analyses. RESULTS Ten studies with 12 effect sizes were eligible for inclusion in this analysis. The overall SMD revealed that CPAP therapy significantly increased TAC [SMD 0.497; 95% CI: 0.21 to 0.77; p: 0.00] in OSA. Analyses based on subgroups showed that the effect of CPAP therapy was significant in all subgroups according to therapy duration, age, BMI, and AHI. Whereas the meta-regression results indicated that the impact of therapy with CPAP on TAC is associated with AHI, BMI, and age in patients with OSA. CONCLUSIONS The finding of this meta-analysis demonstrated a favorable impact of CPAP therapy on TAC levels in patients suffering from OSA.
Collapse
|
84
|
Basili S, Miglionico M, Cangemi R. Exploring additional strategy to improving cognitive skills in older adults. Intern Emerg Med 2023; 18:1267-1268. [PMID: 37120778 DOI: 10.1007/s11739-023-03276-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 04/11/2023] [Indexed: 05/01/2023]
|
85
|
Knauert MP, Adekolu O, Xu Z, Deng A, Chu JH, Baldassarri SR, Kushida C, Yaggi HK, Zinchuk A. Morning Chronotype Is Associated with Improved Adherence to Continuous Positive Airway Pressure among Individuals with Obstructive Sleep Apnea. Ann Am Thorac Soc 2023; 20:1182-1191. [PMID: 36917194 PMCID: PMC10405611 DOI: 10.1513/annalsats.202210-885oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 03/13/2023] [Indexed: 03/16/2023] Open
Abstract
Rationale: Poor adherence limits the effectiveness of continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea (OSA). A better understanding of CPAP adherence is needed to develop novel strategies to improve it. Objectives: To determine if the chronotype (morning, evening, or intermediate) of patients with OSA is associated with differences in CPAP adherence. If such an association exists, determine the mechanisms underlying this association. Methods: We performed a secondary analysis of the APPLES (Apnea Positive Pressure Long-term Efficacy Study) clinical trial. We assessed chronotype using the Morningness-Eveningness Questionnaire (MEQ) among participants randomized to the CPAP arm with daily adherence data (n = 469). Evening (MEQ ⩽ 41), intermediate (41 < MEQ < 59), and morning type (MEQ ⩾ 59) categories were the exposures. We modeled daily CPAP use (hours per night) over a 6-month period, using a linear mixed model, adjusted for covariates (e.g., age, sex, marital status). To assess mechanisms of the association, we performed mediation analyses using sleep duration, weekend catch-up sleep, depression, and other factors. Results: Most participants were obese men with severe OSA (body mass index of 32.3 ± 7.3 kg/m2, 65% male, and apnea-hypopnea index 39.8 ± 24.6/h). Participants were 44% morning, 47% intermediate, and 8% evening chronotype. Participants with the morning chronotype reported the shortest sleep duration on weekends (7.3 vs. 7.6 and 7.9 h/night) compared with the intermediate and evening types. Participants with the morning chronotype exhibited a 40-min/night higher CPAP use (P = 0.001) than persons with the intermediate chronotype. This relationship was mildly attenuated (32.8 min/night; P = 0.011) after adjustment for covariates. None of the selected factors (e.g., sleep duration, weekend catch-up sleep) exhibited a significant mediation effect. Conclusions: Morning chronotype is associated with a clinically meaningful increase in CPAP adherence compared with other chronotypes. Mechanisms of this association require further study. Chronotype may be a novel predictor of CPAP adherence. Clinical trial registered with www.clinicaltrials.gov (NCT00051363).
Collapse
|
86
|
Ratneswaran D, Cheng M, Nasser E, Madula R, Pengo M, Hope K, Schwarz EI, Luo Y, Kaltsakas G, Polkey MI, Moxham J, Steier J. Domiciliary transcutaneous electrical stimulation in patients with obstructive sleep apnoea and limited adherence to continuous positive airway pressure therapy: a single-centre, open-label, randomised, controlled phase III trial. EClinicalMedicine 2023; 62:102112. [PMID: 37654667 PMCID: PMC10466238 DOI: 10.1016/j.eclinm.2023.102112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 09/02/2023] Open
Abstract
Background Hypoglossal nerve stimulation (HNS) for obstructive sleep apnoea (OSA) is a novel way to manage the condition. We hypothesised that in patients with OSA and limited adherence to continuous positive airway pressure (CPAP) therapy, domiciliary transcutaneous electrical stimulation (TESLA) would control sleep apnoea and provide health benefits. Methods We undertook a single-centre, open-label, randomised, controlled phase III trial in patients with OSA (apnoea-hypopnoea-index [AHI] 5-35 h-1), a BMI of 18.5-32 kg∗m-2, and a documented lack of adherence to CPAP therapy (<4 h∗night-1) at Guy's & St Thomas' NHS Foundation Trust (hospital), UK. Patients were randomly assigned (1:1) using minimisation (gender and OSA severity) to receive TESLA or usual care (CPAP) for at least 3 months; sleep study analysis was provided without knowledge of the assignment arm. The primary outcome was change in AHI at 3-months. The primary outcome and safety were analysed in the intention-to-treat population. Data are reported as median (interquartile range), unless otherwise explained. This trial is registered at ClinicalTrials.gov, NCT03160456. Findings Between 6 June 2018 and 7 February 2023, 56 participants were enrolled and randomly assigned (29 patients in the intervention group and 27 in the usual care group). Patients were followed up for a median of 3.0 months (IQR 3.0; 10.0). The groups were similar in terms of age (55.8 (48.2; 66.0) vs 59.3 (47.8; 64.4) years), gender (male:female, 19:10 vs 18:9) and BMI (28.7 (26.4; 31.9) vs 28.4 (24.4; 31.9) kg∗m-2). The unadjusted group difference in the Δ AHI was -11.5 (95% CI -20.7; -2.3) h-1 (p = 0.016). Adjusted for the baseline value, the difference was Δ AHI -7.0 (-15.7; 1.8) h-1 (p = 0.12), in favour of the intervention. Minor adverse events were found in one of the participants who developed mild headaches related to the intervention. Interpretation Domiciliary TESLA can be used safely and effectively in OSA patients with poor adherence to CPAP, with favourable impact on sleepiness and sleep fragmentation. Despite pandemic-related limitations of the amended protocol this trial provides the evidence that TESLA improves clinically meaningful outcomes over the observed follow up period, and the transcutaneous approach is likely to offer an affordable alternative for responders to electrical stimulation in clinical practice. Funding British Lung Foundation, United Kingdom Clinical Research Collaboration-registered King's Clinical Trials Unit at King's Health Partners.
Collapse
|
87
|
Tinoco HA, Perdomo-Hurtado L, Henao-Cruz JA, Escobar-Serna JF, Jaramillo-Robledo O, Aguirre-Ospina OD, Hurtado-Hernández M, Lopez-Guzman J. Evaluation and Performance of a Positive Airway Pressure Device ( CPAP-AirFlife™): A Randomized Crossover Non-Inferiority Clinical Study in Normal Subjects. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1372. [PMID: 37629662 PMCID: PMC10456951 DOI: 10.3390/medicina59081372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/21/2023] [Accepted: 07/21/2023] [Indexed: 08/27/2023]
Abstract
Background and Objectives: During the COVID-19, the demand for non-invasive ventilatory support equipment significantly increased. In response, a novel non-invasive ventilatory support model called CPAP-AirFlife™ was developed utilizing existing technologies. This model offers technological advantages, including an aerosol-controlled helmet suitable for high-risk environments such as ambulances. Additionally, it is cost-effective and does not require medical air, making it accessible for implementation in low-level hospitals, particularly in rural areas. This study aimed to assess the efficacy of CPAP-AirFlife™ by conducting a non-inferiority comparison with conventional ventilation equipment used in the Intensive Care Unit. Materials and Methods: A clinical study was conducted on normal subjects in a randomized and sequential manner. Parameters such as hemoglobin oxygen saturation by pulse oximetry, exhaled PCO2 levels, vital signs, and individual tolerance were compared between the CPAP-AirFlife™ and conventional equipment. The study population was described in terms of demographic characteristics and included in the analysis. Results: It was shown that the CPAP-AirFlife™ was not inferior to conventional equipment in terms of efficacy or tolerability. Hemoglobin oxygen saturation levels, exhaled PCO2 levels, vital signs, and individual tolerance did not significantly differ between the two models. Conclusions: The findings suggest that CPAP-AirFlife™ is a practical and cost-effective alternative for non-invasive ventilatory support. Its technological advantages, including the aerosol-controlled helmet, make it suitable for high-risk environments. The device's accessibility and affordability make it a promising solution for implementation in low-level hospitals, particularly in rural areas. This study supports using CPAP-AirFlife™ as a practical option for non-invasive ventilatory support, providing a valuable contribution to respiratory care during the COVID-19 pandemic and beyond.
Collapse
|
88
|
Miller AG, Kumar KR, Adagarla BS, Haynes KE, Watts RM, Muddiman JL, Heath TS, Allareddy V, Rotta AT. Noninvasive Ventilation or CPAP for Postextubation Support in Small Infants. Respir Care 2023; 69:respcare.11194. [PMID: 37491072 PMCID: PMC10753612 DOI: 10.4187/respcare.11194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2023]
Abstract
BACKGROUND Infants with a high risk of extubation failure are often treated with noninvasive ventilation (NIV) or CPAP, but data on the role of these support modalities following extubation are sparse. This report describes our experience using NIV or CPAP to support infants following extubation in our pediatric ICUs (PICUs). METHODS We performed a retrospective study of children < 10 kg receiving postextubation NIV or CPAP in our PICUs. Data on demographics, medical history, type of support, vital signs, pulse oximetry, near-infrared spectroscopy (NIRS), gas exchange, support settings, and re-intubation were extracted from the electronic medical record. Support was classified as prophylactic if planned before extubation and rescue if initiated within 24 h of extubation. We compared successfully extubated and re-intubated subjects using chi-square test for categorical variables and Mann-Whitney test for continuous variables. RESULTS We studied 51 subjects, median age 44 (interquartile range 0.5-242) d and weight 3.7 (3-4.9) kg. There were no demographic differences between groups, except those re-intubated were more likely to have had cardiac surgery prior to admission (0% vs 14%, P = .040). NIV was used in 31 (61%) and CPAP in 20 (39%) subjects. Prophylactic support was initiated in 25 subjects (49%), whereas rescue support was needed in 26 subjects (51%). Twenty-two subjects (43%) required re-intubation. Re-intubation rate was higher for rescue support (58% vs 28%, P = .032). Subjects with a pH < 7.35 (4.3% vs 42.0%, P = .003) and lower somatic NIRS (39 [24-56] vs 62 [46-72], P = .02) were more likely to be re-intubated. The inspiratory positive airway pressure, expiratory positive airway pressure, and FIO2 were higher in subjects who required re-intubation. CONCLUSIONS NIV or CPAP use was associated with a re-intubation rate of 43% in a heterogeneous sample of high-risk infants. Acidosis, cardiac surgery, higher FIO2 , lower somatic NIRS, higher support settings, and application of rescue support were associated with the need for re-intubation.
Collapse
|
89
|
Law M, Villar S, Oscroft N, Stoneman V, Fox-Rushby J, Chiu YD, Steele J, Devine T, Francis C, Claydon T, Hill G, Lim KK, Rayner J, Williams M, Spires E, Quinnell T. Continuous Positive Airway Pressure plus Mandibular Advancement Therapy (PAPMAT): study protocol for an adaptive randomised crossover trial comparing the benefits and costs of combining two established treatments for obstructive sleep apnoea. Trials 2023; 24:474. [PMID: 37488626 PMCID: PMC10367275 DOI: 10.1186/s13063-023-07484-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 06/28/2023] [Indexed: 07/26/2023] Open
Abstract
BACKGROUND Obstructive sleep apnoea (OSA) involves repeated breathing pauses during sleep due to upper airway obstruction. It causes excessive daytime sleepiness and has other health impacts. Continuous positive airway pressure (CPAP) therapy is effective first line treatment for moderate to severe OSA. Unfortunately, many patients have difficulty tolerating CPAP and pressure intolerance is probably an important contributing factor. Mandibular advancement devices (MAD) are an alternative to CPAP. They are worn in the mouth during sleep to reduce airway obstruction. There is some evidence that, when used in combination with CPAP, MADs improve airway anatomy enough to reduce the CPAP pressure required to treat OSA and that this combination therapy could improve CPAP adherence. METHODS Consecutive patients starting on CPAP for moderate to severe OSA will be recruited at a regional NHS sleep service. Patients with high CPAP pressure requirements after initial titration, who satisfy all entry criteria and consent to participate, will undertake a 2-arm randomised crossover trial. The arms will be (i) standalone CPAP and (ii) CPAP + MAD therapy. Each arm will last 12 weeks, including 2 weeks acclimatisation. CPAP machines will be auto-titrating and with facility for data download, so the impact of MAD on CPAP pressure requirements and CPAP adherence can be easily measured. The primary outcome will be CPAP adherence. Secondary outcomes will include measures of OSA severity, patient-reported outcome measures including subjective daytime sleepiness, quality of life, and treatment preference at the trial exit and health service use. Cost-effectiveness analyses will be undertaken. DISCUSSION If the intervention is shown to be effective and cost-effective in improving adherence in this standard CPAP-eligible OSA patient population it would be relatively straightforward to introduce into existing OSA treatment pathways, within the wider NHS and more widely. Both MAD and CPAP are already used by sleep services so their combination would require only minor adjustments to existing clinical pathways. It would be straightforward to disseminate the results of the study through regional, national, and international respiratory meetings. The health economics analysis would provide cost-effectiveness data to inform service planning and clinical guidelines through policy briefing papers, including those by NICE and SIGN. TRIAL REGISTRATION PAPMAT was registered with ISRCTN prior to recruitment beginning (ISRCTN Registry 2021): https://www.isrctn.com/ISRCTN33966032 . Registered on 17th November 2021.
Collapse
|
90
|
Stilo G, Vicini C, Pollicina I, Maniaci A, Lechien JR, Calvo-Henríquez C, Yáñez MM, Iannella G, Pace A, Cammaroto G, Meccariello G, Cannavicci A, Moffa A, Casale M, La Mantia I. Is Continuous Positive Airway Pressure a Valid Alternative to Sildenafil in Treating Sexual Dysfunction among OSA Patients? A Systematic Review and Meta-Analysis. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1318. [PMID: 37512129 PMCID: PMC10384051 DOI: 10.3390/medicina59071318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 06/26/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: This study aimed to assess the comparative effectiveness of continuous positive airway pressure (CPAP) therapy and sildenafil pharmacological therapy in improving sexual function among patients with obstructive sleep apnea (OSA) and erectile dysfunction (ED). Materials and methods: Population: Patients affected by OSA and ED; Intervention: CPAP therapy vs. Comparison: Sildenafil pharmacological therapy; Outcomes: Improvement in erectile function, as measured by the International Index of Erectile Function 5 (IIEF-5) scoring system; Time: A systematic review of the literature from the past 20 years; Study Design: Observational studies comparing erectile function improvements after OSA treatment. Results: A total of eight papers were included in the qualitative summary, involving four hundred fifty-seven patients with ED and OSA. Erectile function improvements were observed in both treatment groups. After sildenafil and CPAP treatment, the mean IIEF-5 domain scores were 37.7 and 27.3, respectively (p < 0.001). Sildenafil 100 mg demonstrated a higher therapeutic impact compared to CPAP treatment. Conclusions: CPAP therapy significantly improved sexual parameters in most studies for OSA patients with ED. The findings suggest that CPAP therapy effectively alleviates erectile dysfunction symptoms, resulting in improved sexual performance in OSA patients. The comparison of the two treatments indicates that sildenafil has a more substantial therapeutic impact on erectile function than CPAP therapy; however, a combined treatment will provide a cumulative effect.
Collapse
|
91
|
Hashim NA, Al-Umeri KK, Hameed AM. The role of CT-scan in the diagnosis and prognosis of COVID-19 in a sample of Iraqi patients referred to Al-Diwaniyah Teaching Hospital, Iraq. J Med Life 2023; 16:1079-1083. [PMID: 37900087 PMCID: PMC10600670 DOI: 10.25122/jml-2023-0065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 06/05/2023] [Indexed: 10/31/2023] Open
Abstract
The respiratory system is the primary target of the SARS-CoV-2 virus, leading to clinical manifestations such as dry cough, fever, and shortness of breath. Other reported manifestations include generalized weakness, dizziness, headache, vomiting, and diarrhea. A chest CT scan is one of the best imaging tools to screen and diagnose COVID-19. This prospective observational study was conducted at Al-Diwaniyah Teaching Hospital in the mid-Euphrates region of Iraq to assess the prognostic role of chest CT examinations in COVID-19 patients between February 2020 and July the 15th, 2020. The study included 100 patients suspected of COVID-19 based on clinical features and microbiological investigations, comprising 72 males and 28 females aged between 30 and 55. All patients were SARS-CoV-2 PCR positive and had no history of chronic lung disease. We categorized patients into two groups based on changes in density and lesion area: patients with changes (n=55) and patients without changes (n=45). Furthermore, we divided all patients into three groups according to treatment requirements and symptom severity: group 1 included patients with severe symptoms who required CPAP and admission to the Respiratory Care Unit, group 2 consisted of patients with moderate symptoms who needed oxygen therapy and hospital admission, and group 3 comprised patients with mild symptoms who were treated as outpatients with medication. Upon correlating the change in density and lesion area with these groups, we observed that most patients with no changes were in group 1, while patients with changes were predominantly seen in group 2. Additionally, the ratio of lesion area in the mediastinal CT window to lung CT was identified as a potential prognostic factor for COVID-19 patients.
Collapse
|
92
|
Vishwa CR, Nallasamy K, Angurana SK, Bansal A, Jayashree M. Pressure support versus continuous positive airway pressure for predicting successful liberation from invasive ventilation in children: an open label, randomized non-inferiority trial. THE LANCET REGIONAL HEALTH. SOUTHEAST ASIA 2023; 14:100219. [PMID: 37492415 PMCID: PMC10363498 DOI: 10.1016/j.lansea.2023.100219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 03/18/2023] [Accepted: 05/08/2023] [Indexed: 07/27/2023]
Abstract
Background Pressure support (PS) as a spontaneous breathing trial (SBT) was considered inferior to continuous positive airway pressure (CPAP) and T-piece because PS underestimated post-extubation work of breathing in physiologic studies. We aimed to compare PS and CPAP as SBT methods for assessing clinical outcomes in children. Methods This was an open label randomized non-inferiority trial conducted between December 2019 and August 2021 among children aged 1 month to 12 years deemed ready for weaning after at least 48 h of invasive ventilation in PICU. Children were randomized to undergo a 2-h SBT with PS of 8 cm H2O in addition to PEEP 5-6 cm H2O or CPAP (5-6 cm H2O). The primary outcome was successful liberation from invasive ventilation for 72 h after first SBT. Secondary outcomes included first SBT pass rate, need for post-extubation respiratory support (high flow oxygen and/or non-invasive ventilation), and length of PICU stay. Findings Of the 247 enrolled children, 244 completed the trial (121 in PS and 123 in CPAP group). Median (IQR) age was 24 (9, 84) months. Median (IQR) duration of invasive ventilation before randomization was 4.5 (3, 6.5) days. Successful liberation from invasive ventilation after first SBT occurred in 97 (80.2%) children in PS and 93 (75.6%) children in CPAP group [difference 4.6; 95% CI (-5.8, 15); p = 0.39]. First SBT pass rate between PS and CPAP [111 (91.7%) versus 105 (85.4%); difference 6.3; 95% CI (-1.6, 14.3); p = 0.12] was similar. Need for post-extubation respiratory support [52 (43%) versus 49 (40%)], rate of reintubation within 72 h [14 (11.6%) versus 12 (9.8%)] and median (IQR) length of PICU stay [9 (6, 15) versus 8 (5.5, 13) days] were comparable. Four (1.6%) children, all in CPAP group had unfavourable outcome (1 died, 3 discontinued care). Interpretation In invasively ventilated children, 2-h SBT with pressure support was non-inferior to CPAP in predicting successful liberation from invasive ventilation. Funding None.
Collapse
|
93
|
Donovan LM, Hoyos CM, Kimoff RJ, Morrell MJ, Bosch NA, Chooljian DM, McEvoy RD, Sawyer AM, Wagner TH, Al-Lamee RR, Bishop D, Carno MA, Epstein M, Hanson M, Ip MSM, Létourneau M, Pamidi S, Patel SR, Pépin JL, Punjabi NM, Redline S, Thornton JD, Patil SP. Strategies to Assess the Effect of Continuous Positive Airway Pressure on Long-Term Clinically Important Outcomes among Patients with Symptomatic Obstructive Sleep Apnea: An Official American Thoracic Society Workshop Report. Ann Am Thorac Soc 2023; 20:931-943. [PMID: 37387624 DOI: 10.1513/annalsats.202303-258st] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/01/2023] Open
Abstract
Continuous positive airway pressure (CPAP) is the first-line treatment for obstructive sleep apnea (OSA). Although CPAP improves symptoms (e.g., daytime sleepiness), there is a lack of high-quality evidence that CPAP prevents many long-term outcomes, including cognitive impairment, myocardial infarction, and stroke. Observational studies suggest that patients with symptoms may be particularly likely to experience these preventive benefits with CPAP, but ethical and practical concerns limited the participation of such patients in prior long-term randomized trials. As a result, there is uncertainty about the full benefits of CPAP, and resolving this uncertainty is a key priority for the field. This workshop assembled clinicians, researchers, ethicists, and patients to identify strategies to understand the causal effects of CPAP on long-term clinically important outcomes among patients with symptomatic OSA. Quasi-experimental designs can provide valuable information and are less time and resource intensive than trials. Under specific conditions and assumptions, quasi-experimental studies may be able to provide causal estimates of CPAP's effectiveness from generalizable observational cohorts. However, randomized trials represent the most reliable approach to understanding the causal effects of CPAP among patients with symptoms. Randomized trials of CPAP can ethically include patients with symptomatic OSA, as long as there is outcome-specific equipoise, adequate informed consent, and a plan to maximize safety while minimizing harm (e.g., monitoring for pathologic sleepiness). Furthermore, multiple strategies exist to ensure the generalizability and practicality of future randomized trials of CPAP. These strategies include reducing the burden of trial procedures, improving patient-centeredness, and engaging historically excluded and underserved populations.
Collapse
|
94
|
Perger E, Bertoli S, Lombardi C. Pharmacotherapy for obstructive sleep apnea: targeting specific pathophysiological traits. Expert Rev Respir Med 2023; 17:663-673. [PMID: 37646222 DOI: 10.1080/17476348.2023.2241353] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 07/24/2023] [Indexed: 09/01/2023]
Abstract
INTRODUCTION The pathophysiology of obstructive sleep apnea (OSA) is multi-factorial and complex. Varying OSA's pathophysiological traits have been identified, including pharyngeal collapsibility, upper airway muscle reactivity, arousal threshold, and regulation of the ventilatory drive. Being CPAP of difficult tolerance and other interventions reserved to specific subpopulations new pharmacological treatments for OSA might be resolutive. AREAS COVERED Several existing and newly developed pharmacological drugs can impact one or more endotypes and could therefore be proposed as treatment options for sleep disordered breathing. With this review we will explore different pathophysiological traits as new targets for OSA therapy. This review will summarize the most promising pharmacological treatment for OSA accordingly with their mechanisms of action on upper airway collapsibility, muscle responsiveness, arousal threshold, and loop gain. EXPERT OPINION Only understanding the pathophysiological traits causing OSA in each patient and placing the disease in the framework of patient comorbidities, we will be able to evolve interventions toward OSA. The development of new drug's combinations will permit different approaches and different choices beside conventional treatments. In the next future, we hope that sleep specialists will select the treatment for a specific patient on the base of its pathophysiology, defining a precision medicine for OSA.
Collapse
|
95
|
Wilson‐Baig N, Walker R. Relief of laryngospasm with gentle chest compressions during direct laryngotracheobronchoscopy. Anaesth Rep 2023; 11:e12268. [PMID: 38144714 PMCID: PMC10746857 DOI: 10.1002/anr3.12268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/30/2023] [Indexed: 12/26/2023] Open
|
96
|
Kundel V, Cohen O, Khan S, Patel M, Kim-Schulze S, Kovacic J, Suárez-Fariñas M, Shah NA. Advanced Proteomics and Cluster Analysis for Identifying Novel Obstructive Sleep Apnea Subtypes before and after Continuous Positive Airway Pressure Therapy. Ann Am Thorac Soc 2023; 20:1038-1047. [PMID: 36780659 DOI: 10.1513/annalsats.202210-897oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 02/13/2023] [Indexed: 02/15/2023] Open
Abstract
Rationale: Studies have shown elevated inflammatory biomarkers in obstructive sleep apnea (OSA), but data after continuous positive airway pressure (CPAP) treatment are inconsistent. Objectives: We used the Olink proteomics panel to identify unique OSA clusters on the basis of inflammatory protein expression and assess the impact of CPAP therapy. Methods: Adults with newly diagnosed OSA had blood drawn at baseline and three to four months after CPAP. Samples were analyzed using the Olink proteomics platform, which measures 92 prespecified inflammatory proteins using proximity extension assay. Linear mixed-effects models were used to model changes in protein expression during the period of CPAP use, adjusting for batch, age, and sex. Unsupervised hierarchical clustering was performed to identify unique inflammatory OSA clusters on the basis of inflammatory biomarkers. Within-cluster impact of CPAP on inflammatory protein expression was assessed. Results: Among 46 patients, the mean age was 46 ± 12 years (22% women), mean body mass index was 31 ± 5 kg/m2, and mean respiratory disturbance index was 33 ± 17 events/hour. Unsupervised cluster and heatmap analysis revealed three unique proteomic clusters, with low (n = 21), intermediate (n = 19), and high (n = 6) inflammatory protein expression. After CPAP, there were significant within-cluster differences in protein expression. The low inflammatory cluster had a significant increase in protein expression (16%; P = 0.02), and the high inflammatory cluster had a significant decrease in protein expression (-20%; P = 0.003), more significant among those compliant with CPAP in the low (25%; P = 0.04) and high (-22%; P = 0.01) clusters. Conclusions: We identified three unique inflammatory clusters in patients with OSA using plasma proteomics, with a differential response to CPAP by cluster. Our results are hypothesis generating and require further investigation in larger longitudinal studies for enhanced cardiovascular risk profiling in OSA.
Collapse
|
97
|
Katasani T, Holt G, Al-Khyatt W, Idris I. Peri- and Postoperative Outcomes for Obstructive Sleep Apnoea Patients after Bariatric Surgery-a Systematic Review and Meta-analysis. Obes Surg 2023; 33:2016-2024. [PMID: 37140722 PMCID: PMC10289925 DOI: 10.1007/s11695-023-06557-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/13/2023] [Accepted: 03/21/2023] [Indexed: 05/05/2023]
Abstract
BACKGROUND Obstructive sleep apnoea (OSA) is prevalent among patients undergoing bariatric surgery. Previous studies have reported a higher risk of complications, ICU admission and longer length of stay in patients with OSA following surgery. However, clinical outcomes following bariatric surgery are unclear. The hypothesis is that patients with OSA will have an increased risk of these outcome measures after bariatric surgery. METHODS A systematic review and meta-analysis were performed to answer the research question. Searches for bariatric surgery and obstructive sleep apnoea were performed using PubMed and Ovid Medline. Studies which compared OSA and non-OSA patients undergoing bariatric surgery and used outcome measures that included length of stay, risk of complications, 30-day readmission and need for ICU admission were selected for the systematic review. Comparable datasets from these studies were used for the meta-analysis. RESULTS Patients with OSA are at greater risk of complications after bariatric surgery (RR = 1.23 [CI: 1.01, 1.5], P = 0.04), driven mostly by an increased risk of cardiac complications (RR = 2.44 [CI: 1.26, 4.76], P = 0.009). There were no significant differences between the OSA and non-OSA cohorts in the other outcome variables (respiratory complications, length of stay, 30-day readmission and need for ICU admission). CONCLUSION Following bariatric surgery, patients with OSA must be managed carefully due to the increased risk of cardiac complications. However, patients with OSA are not more likely to require a longer length of stay or readmission.
Collapse
|
98
|
Aguilar H, Kahanowitch R, Weiss M, Ortiz-Vergara MC, Lew J, Rodriguez O, Nino G. Real-world data evaluation of PAP responsiveness in pediatric obstructive sleep apnea. J Clin Sleep Med 2023; 19:1313-1319. [PMID: 37032622 PMCID: PMC10315588 DOI: 10.5664/jcsm.10578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 03/12/2023] [Accepted: 03/14/2023] [Indexed: 04/11/2023]
Abstract
STUDY OBJECTIVES The use of positive airway pressure (PAP) in children is a complex process determined by multiple factors. There are limited data on the response of the pediatric population to PAP therapy at home. The goal of the study was to examine real-world responses using PAP home monitoring in children with obstructive sleep apnea. METHODS The study included PAP therapy data for 195 children aged between 1 month and 18 years with obstructive sleep apnea and polysomnogram baseline study. We collected demographics, clinical variables, and polysomnogram parameters in all study participants. The individual response to PAP therapy was calculated comparing the apnea-hypopnea index (AHI) in the initial polysomnogram with the mean AHI provided by the download of PAP devices. Multivariate models (logistic regression) were used to examine the predictors of positive PAP response defined as a reduction in AHI ≥ 75%. RESULTS We found excellent responses to PAP therapy in children (median 85% AHI reduction). However, there was substantial heterogeneity in AHI reductions while on PAP therapy. The best PAP responses were linked to more severe obstructive sleep apnea and higher PAP levels. We also identified that the response to PAP was higher in obese children and lower in males. The best predictive model for individual PAP response was biological sex, obesity, and obstructive AHI ≥ 20 events/h (area under the receiver operating characteristic curve of 0.791). CONCLUSIONS Real-world data show that PAP is overall an effective therapy in children but the response is heterogeneous. Obstructive sleep apnea parameters and individual factors can be used to predict individual AHI reductions while on PAP and optimize PAP responses at home. CITATION Aguilar H, Kahanowitch R, Weiss M, et al. Real-world data evaluation of PAP responsiveness in pediatric obstructive sleep apnea. J Clin Sleep Med. 2023;19(7):1313-1319.
Collapse
|
99
|
Immordino A, Lorusso F, Sireci F, Dispenza F. Acute pneumolabyrinth: a rare complication after cochlear implantation in a patient with obstructive sleep apnoea on CPAP therapy. BMJ Case Rep 2023; 16:e254069. [PMID: 37399343 PMCID: PMC10314444 DOI: 10.1136/bcr-2022-254069] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/05/2023] Open
Abstract
Pneumolabyrinth is a condition characterised by the presence of air within the inner ear and is a rare complication after cochlear implant surgery. One of the causes of pneumolabyrinth may be the increase in pressure in the middle ear. The use of continuous positive airway pressure (CPAP) is an effective treatment strategy for obstructive sleep apnoea. According to a recent study, the use of CPAP should be delayed by 1 or 2 weeks in subjects undergoing middle ear surgery; however, there is currently no indication to delay the CPAP in subjects undergoing cochlear implant surgery. We report the case of a patient on CPAP who underwent left cochlear implantation and, in the early postoperative period, reported severe vertigo and tinnitus. Cone-beam CT of the temporal bone revealed the presence of pneumolabyrynth. We believe that the use of CPAP should be delayed in subjects undergoing cochlear implantation to avoid the development of acute pneumolabyrinth.
Collapse
|
100
|
Cutuli SL, Grieco DL, Michi T, Cesarano M, Rosà T, Pintaudi G, Menga LS, Ruggiero E, Giammatteo V, Bello G, De Pascale G, Antonelli M. Personalized Respiratory Support in ARDS: A Physiology-to-Bedside Review. J Clin Med 2023; 12:4176. [PMID: 37445211 DOI: 10.3390/jcm12134176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/19/2023] [Accepted: 06/19/2023] [Indexed: 07/15/2023] Open
Abstract
Acute respiratory distress syndrome (ARDS) is a leading cause of disability and mortality worldwide, and while no specific etiologic interventions have been shown to improve outcomes, noninvasive and invasive respiratory support strategies are life-saving interventions that allow time for lung recovery. However, the inappropriate management of these strategies, which neglects the unique features of respiratory, lung, and chest wall mechanics may result in disease progression, such as patient self-inflicted lung injury during spontaneous breathing or by ventilator-induced lung injury during invasive mechanical ventilation. ARDS characteristics are highly heterogeneous; therefore, a physiology-based approach is strongly advocated to titrate the delivery and management of respiratory support strategies to match patient characteristics and needs to limit ARDS progression. Several tools have been implemented in clinical practice to aid the clinician in identifying the ARDS sub-phenotypes based on physiological peculiarities (inspiratory effort, respiratory mechanics, and recruitability), thus allowing for the appropriate application of personalized supportive care. In this narrative review, we provide an overview of noninvasive and invasive respiratory support strategies, as well as discuss how identifying ARDS sub-phenotypes in daily practice can help clinicians to deliver personalized respiratory support and potentially improve patient outcomes.
Collapse
|