76
|
Atry F, Rentchler E, Alkmin S, Dai B, Li B, Eliceiri KW, Campagnola PJ. Parallel multiphoton excited fabrication of tissue engineering scaffolds using a diffractive optical element. OPTICS EXPRESS 2020; 28:2744-2757. [PMID: 32121956 PMCID: PMC7053494 DOI: 10.1364/oe.381362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/21/2019] [Accepted: 12/25/2019] [Indexed: 05/08/2023]
Abstract
Multiphoton excited photochemistry is a powerful technique for freeform nano/microfabrication. However, the construction of large and complex structures using single point scanning is slow, where this is a significant limitation for biological investigations. We demonstrate increased throughput via parallel fabrication using a diffractive optical element. To implement an approach with large field of view and near-theoretical resolution, a scan lens was designed that is optimized for using low-magnification high NA objective lenses. We demonstrate that with this approach it is possible to synthesize large scaffolds at speeds several times faster than by single point scanning.
Collapse
|
77
|
Choi M, Kim S, Choi SH, Park HH, Byun KM. Highly reliable SERS substrate based on plasmonic hybrid coupling between gold nanoislands and periodic nanopillar arrays. OPTICS EXPRESS 2020; 28:3598-3606. [PMID: 32122025 DOI: 10.1364/oe.386726] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 01/17/2020] [Indexed: 05/26/2023]
Abstract
To improve both sensitivity and reliability, a hybrid SERS substrate of combining gold nanoislands (GNI) with periodic MgF2 nanopillar arrays was successfully developed. SERS detection performance of the proposed substrates was evaluated in terms of enhancement effect, signal-to-noise ratio (SNR), linearity, reproducibility and repeatability, and compared with the performance of a conventional SERS substrate based on GNI. Experimental and simulation results presented that significant improvement of SERS intensity and SNR by more than 3 times and a notable reduction in relative standard deviation were obtained. We hope that the suggested SERS platform with unique advantages in sensitivity and reliability could be extended to point-of-care detection of a variety of biomolecular reactions.
Collapse
|
78
|
Zhao Y, Rafatian N, Wang EY, Wu Q, Lai BFL, Lu RX, Savoji H, Radisic M. Towards chamber specific heart-on-a-chip for drug testing applications. Adv Drug Deliv Rev 2020; 165-166:60-76. [PMID: 31917972 PMCID: PMC7338250 DOI: 10.1016/j.addr.2019.12.002] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 12/26/2019] [Accepted: 12/30/2019] [Indexed: 02/06/2023]
Abstract
Modeling of human organs has long been a task for scientists in order to lower the costs of therapeutic development and understand the pathological onset of human disease. For decades, despite marked differences in genetics and etiology, animal models remained the norm for drug discovery and disease modeling. Innovative biofabrication techniques have facilitated the development of organ-on-a-chip technology that has great potential to complement conventional animal models. However, human organ as a whole, more specifically the human heart, is difficult to regenerate in vitro, in terms of its chamber specific orientation and its electrical functional complexity. Recent progress with the development of induced pluripotent stem cell differentiation protocols, made recapitulating the complexity of the human heart possible through the generation of cells representative of atrial & ventricular tissue, the sinoatrial node, atrioventricular node and Purkinje fibers. Current heart-on-a-chip approaches incorporate biological, electrical, mechanical, and topographical cues to facilitate tissue maturation, therefore improving the predictive power for the chamber-specific therapeutic effects targeting adult human. In this review, we will give a summary of current advances in heart-on-a-chip technology and provide a comprehensive outlook on the challenges involved in the development of human physiologically relevant heart-on-a-chip.
Collapse
|
79
|
Long S, Xiao Y, Zhang X. Progress in Preparation of Silk Fibroin Microspheres for Biomedical Applications. Pharm Nanotechnol 2020; 8:358-371. [PMID: 33038918 DOI: 10.2174/2211738508666201009123235] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 06/25/2020] [Accepted: 08/21/2020] [Indexed: 06/11/2023]
Abstract
As a natural biomaterial, silk fibroin (SF) holds great potential in biomedical applications with its broad availability, good biocompatibility, high mechanical strength, ease of fabrication, and controlled degradation. With emerging fabrication methods, nanoand microspheres made from SF have brought about unique opportunities in drug delivery, cell culture, and tissue engineering. For these applications, the size and distribution of silk fibroin particles (SFPs) are critical and require precise control during fabrication. Herein, we review common and emerging SFPs fabrication methods and their biomedical applications, and also the challenges and opportunities for SFPs in the near future. Lay Summary: The application of silk in textile has an extraordinarily long history and new biomedical applications emerged owing to the good biocompatibility and versatile fabrication options of its major protein component, silk fibroin. With the development of nanotechnology and microfabrication, silk fibroin has been fabricated into nano- or microspheres with precisely controlled shape and distribution. In this review, we summarize common and emerging silk fibroin particle fabrication methods and their biomedical applications, and also discuss their challenges and opportunities in the nearest future.
Collapse
|
80
|
Abstract
Stereolithography (SLA) 3D bioprinting has emerged as a prominent bioprinting method addressing the requirements of complex tissue fabrication. This chapter addresses the advancement in SLA 3D bioprinting in concurrent with the development of novel photocrosslinkable biomaterials with enhanced physical and chemical properties. We discuss the cytocompatible photoinitiators operating in the wide spectrum of the ultraviolet (UV) and the visible light and high-resolution dynamic mask projection systems with a suitable illumination source. The potential of SLA 3D bioprinting has been explored in various themes, like bone and neural tissue engineering and in the development of controlled microenvironments to study cell behavior. The flexible design and versatility of SLA bioprinting makes it an attractive bioprinting process with myriad possibilities and clinical applications.
Collapse
|
81
|
Kim EM, Lee YB, Kim SJ, Park J, Lee J, Kim SW, Park H, Shin H. Fabrication of core-shell spheroids as building blocks for engineering 3D complex vascularized tissue. Acta Biomater 2019; 100:158-172. [PMID: 31542503 DOI: 10.1016/j.actbio.2019.09.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 09/06/2019] [Accepted: 09/17/2019] [Indexed: 12/12/2022]
Abstract
Cell spheroids as building blocks for engineering micro-tissue should be able to mimic the complex structure of natural tissue. However, control of the distribution of multiple cell populations within cell spheroids is difficult to achieve with current spheroid-harvest methods such as hanging-drop and with the use of microwell plates. In this study, we report the fabrication of core-shell spheroids with the ultimate goal to form 3D complex micro-tissue. We used endothelial cells and two types of stem cells (human turbinate mesenchymal stem cells (hTMSCs)/adipose-derived stem cells (ADSCs)). The stem cells and endothelial cells formed layered micro-sized cell sheets (µCSs) on polydopamine micro-patterned temperature-responsive hydrogel surfaces by a sequential seeding method, and these layered µCSs self-assembled to form core-shell spheroids by expansion of the hydrogels. The co-cultured spheroids formed a core-shell structure irrespective of stem cell type. In addition, the size of the core-shell spheroids was controlled from 90 ± 1 to 144 ± 3 µm by changing pattern sizes (200, 300, and 400 µm). The shell thickness gradually increased from 12 ± 3 to 30 ± 6 µm by adjusting the endothelial cell seeding density. Finally, we fabricated the micro-tissue by fusion of the co-cultured spheroids, and the spheroids with the core-shell structure rapidly induced in vitro vessel-like network in 3 days. Thus, the position of endothelial cells in co-cultured spheroids may be an important factor for the modulation of the vascularization process, which can be useful for the production of 3D complex micro-tissues using spheroids as building blocks. STATEMENT OF SIGNIFICANCE: This manuscript describes our work on the fabrication of core-shell spheroids as building blocks to form 3D complex vascularized micro-tissue. Stem cells (human turbinate mesenchymal stem cells (hTMSCs) or adipose-derived stem cells (ADSCs)) and endothelial cells formed layered micro-sized cell sheets (µCSs) on micro-patterned temperature-responsive hydrogel surfaces by a sequential seeding method, and these layered µCSs self-assembled to form core-shell spheroids (core - stem cells, shell - endothelial cells), irrespective of stem cell type. In addition, the size and shell thickness of the core-shell spheroids were controlled by modifying pattern size and endothelial cell seeding density. We fabricated the vascularized micro-tissue by fusion of the spheroids and demonstrated that the spheroids with a core-shell structure rapidly induced vessel-like network.
Collapse
|
82
|
Varapula D, LaBouff E, Raseley K, Uppuluri L, Ehrlich GD, Noh M, Xiao M. A micropatterned substrate for on-surface enzymatic labelling of linearized long DNA molecules. Sci Rep 2019; 9:15059. [PMID: 31636335 PMCID: PMC6803683 DOI: 10.1038/s41598-019-51507-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 10/02/2019] [Indexed: 12/22/2022] Open
Abstract
Optical mapping of linearized DNA molecules is a promising new technology for sequence assembly and scaffolding, large structural variant detection, and diagnostics. This is currently achieved either using nanochannel confinement or by stretching single DNA molecules on a solid surface. While the first method necessitates DNA labelling before linearization, the latter allows for modification post-linearization, thereby affording increased process flexibility. Each method is constrained by various physical and chemical limitations. One of the most common techniques for linearization of DNA uses a hydrophobic surface and a receding meniscus, termed molecular combing. Here, we report the development of a microfabricated surface that can not only comb the DNA molecules efficiently but also provides for sequence-specific enzymatic fluorescent DNA labelling. By modifying a glass surface with two contrasting functionalities, such that DNA binds selectively to one of the two regions, we can control DNA extension, which is known to be critical for sequence-recognition by an enzyme. Moreover, the surface modification provides enzymatic access to the DNA backbone, as well as minimizing non-specific fluorescent dye adsorption. These enhancements make the designed surface suitable for large-scale and high-resolution single DNA molecule studies.
Collapse
|
83
|
Aleman J, George SK, Herberg S, Devarasetty M, Porada CD, Skardal A, Almeida-Porada G. Deconstructed Microfluidic Bone Marrow On-A-Chip to Study Normal and Malignant Hemopoietic Cell-Niche Interactions. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1902971. [PMID: 31464364 PMCID: PMC8011350 DOI: 10.1002/smll.201902971] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 07/31/2019] [Indexed: 05/23/2023]
Abstract
Human hematopoietic niches are complex specialized microenvironments that maintain and regulate hematopoietic stem and progenitor cells (HSPC). Thus far, most of the studies performed investigating alterations of HSPC-niche dynamic interactions are conducted in animal models. Herein, organ microengineering with microfluidics is combined to develop a human bone marrow (BM)-on-a-chip with an integrated recirculating perfusion system that consolidates a variety of important parameters such as 3D architecture, cell-cell/cell-matrix interactions, and circulation, allowing a better mimicry of in vivo conditions. The complex BM environment is deconvoluted to 4 major distinct, but integrated, tissue-engineered 3D niche constructs housed within a single, closed, recirculating microfluidic device system, and equipped with cell tracking technology. It is shown that this technology successfully enables the identification and quantification of preferential interactions-homing and retention-of circulating normal and malignant HSPC with distinct niches.
Collapse
|
84
|
Kundu A, Nogueira Campos MG, Santra S, Rajaraman S. Precision Vascular Delivery of Agrochemicals with Micromilled Microneedles (µMMNs). Sci Rep 2019; 9:14008. [PMID: 31570804 PMCID: PMC6768873 DOI: 10.1038/s41598-019-50386-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 09/03/2019] [Indexed: 11/16/2022] Open
Abstract
We demonstrate use of makerspace techniques involving subtractive microtechnologies to fabricate micromilled microneedles (µMMNs) of stainless steel (SS) for precise delivery of agrochemicals into vascular bundles of plant tissue. Precision delivery is of immense importance for systemic pathogen control in specific areas of plant tissue. Optimization of the micromilling allows for selective removal of SS at the microscale and the microfabrication of a 5 × 5 array of µMMNs having both base width and height of 500 µm to enable precise puncture into the stem of citrus saplings. Atomic Absorption Spectroscopy reveals up to 7.5× increase in the uptake of a therapeutic cargo while Scanning Electron Microscopy reveals that specific sites of the vascular bundle; either xylem or the phloem can be uniquely targeted with customized µMMNs. Such rapid and cost-effective customization with intricate designs along with scalability is enabled by makerspace microfabrication. Additionally, a 19 × 20 array of micromilled mesoneedles has been fabricated and affixed to a paint roller as an applicator system for real-world field testing outside the laboratory. Initial results indicate reliable behavior of the applicator system and the technique can be applied to the systemic delivery of agrochemicals while conserving the loss of the agrochemical with increased application efficiency.
Collapse
|
85
|
Abstract
Recent advances in bioprinting technologies have enabled rapid manufacturing of organ-on-chip models along with biomimetic tissue microarchitectures. Bioprinting techniques can be used to integrate microfluidic channels and flow connections in organ-on-chip models. We review bioprinters in two categories of nozzle-based and optical-based methods, and then discuss their fabrication parameters such as resolution, replication fidelity, fabrication time, and cost for micro-tissue models and microfluidic applications. The use of bioprinters has shown successful replicates of functional engineered tissue models integrated within a desired microfluidic system, which facilitates the observation of metabolism or secretion of models and sophisticated control of a dynamic environment. This may provide a wider order of tissue engineering fabrication in mimicking physiological conditions for enhancing further applications such as drug development and pathological studies.
Collapse
|
86
|
Sonntag L, Simmchen J, Magdanz V. Nano-and Micromotors Designed for Cancer Therapy. Molecules 2019; 24:E3410. [PMID: 31546857 PMCID: PMC6767050 DOI: 10.3390/molecules24183410] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 08/30/2019] [Accepted: 09/05/2019] [Indexed: 12/18/2022] Open
Abstract
Research on nano- and micromotors has evolved into a frequently cited research area with innovative technology envisioned for one of current humanities' most deadly problems: cancer. The development of cancer targeting drug delivery strategies involving nano-and micromotors has been a vibrant field of study over the past few years. This review aims at categorizing recent significant results, classifying them according to the employed propulsion mechanisms starting from chemically driven micromotors, to field driven and biohybrid approaches. In concluding remarks of section 2, we give an insight into shape changing micromotors that are envisioned to have a significant contribution. Finally, we critically discuss which important aspects still have to be addressed and which challenges still lie ahead of us.
Collapse
|
87
|
Zhang C, Paria D, Semancik S, Barman I. Composite-Scattering Plasmonic Nanoprobes for Label-Free, Quantitative Biomolecular Sensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1901165. [PMID: 31394029 PMCID: PMC6759334 DOI: 10.1002/smll.201901165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/09/2019] [Indexed: 05/03/2023]
Abstract
Biosensing based on localized surface plasmon resonance (LSPR) relies on concentrating light to a nanometeric spot and leads to a highly enhanced electromagnetic field near the metal nanostructure. Here, a design of plasmonic nanostructures based on rationally structured metal-dielectric combinations is presented, called composite scattering probes (CSPs), to generate an integrated multimodal biosensing platform featuring LSPR and surface-enhanced Raman spectroscopy (SERS). Specifically, CSP configurations are proposed, which have several prominent resonance peaks enabling higher tunability and sensitivity for self-referenced multiplexed analyte sensing. Using electron-beam evaporation and thermal dewetting, large-area, uniform, and tunable CSPs are fabricated, which are suitable for label-free LSPR and SERS measurements. The CSP prototypes are used to demonstrate refractive index sensing and molecular analysis using albumin as a model analyte. By using partial least squares on recorded absorption profiles, differentiation of subtle changes in refractive index (as low as 0.001) in the CSP milieu is demonstrated. Additionally, CSPs facilitate complementary untargeted plasmon-enhanced Raman measurements from the sample's compositional contributors. With further refinement, it is envisioned that the method may lead to a sensitive, versatile, and tunable platform for quantitative concentration determination and molecular fingerprinting, particularly where limited a priori information of the sample is available.
Collapse
|
88
|
Jia Y, Mirbozorgi SA, Lee B, Khan W, Madi F, Inan OT, Weber A, Li W, Ghovanloo M. A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:608-618. [PMID: 31135371 PMCID: PMC6707363 DOI: 10.1109/tbcas.2019.2918761] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This paper presents a mm-sized, free-floating, wirelessly powered, implantable optical stimulation (FF-WIOS) device for untethered optogenetic neuromodulation. A resonator-based three-coil inductive link creates a homogeneous magnetic field that continuously delivers sufficient power (>2.7 mW) at an optimal carrier frequency of 60 MHz to the FF-WIOS in the near field without surpassing the specific absorption rate limit, regardless of the position of the FF-WIOS in a large brain area. Forward data telemetry carries stimulation parameters by on-off-keying the power carrier at a data rate of 50 kb/s to selectively activate a 4 × 4 μLED array. Load-shift-keying back telemetry controls the wireless power transmission by reporting the FF-WIOS received power level in a closed-loop power control mechanism. LEDs typically require high instantaneous power to emit sufficient light for optical stimulation. Thus, a switched-capacitor-based stimulation architecture is used as an energy storage buffer with one off-chip capacitor to receive charge directly from the inductive link and deliver it to the selected μLED at the onset of stimulation. The FF-WIOS system-on-a-chip prototype, fabricated in a 0.35-μm standard CMOS process, charges a 10-μF capacitor up to 5 V with 37% efficiency and passes instantaneous current spikes up to 10 mA in the selected μLED, creating a bright exponentially decaying flash with minimal wasted power. An in vivo experiment was conducted to verify the efficacy of the FF-WIOS by observing light-evoked local field potentials and immunostained tissue response from the primary visual cortex (V1) of two anesthetized rats.
Collapse
|
89
|
Iacovacci V, Blanc A, Huang H, Ricotti L, Schibli R, Menciassi A, Behe M, Pané S, Nelson BJ. High-Resolution SPECT Imaging of Stimuli-Responsive Soft Microrobots. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1900709. [PMID: 31304653 DOI: 10.1002/smll.201900709] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 05/07/2019] [Indexed: 06/10/2023]
Abstract
Untethered small-scale robots have great potential for biomedical applications. However, critical barriers to effective translation of these miniaturized machines into clinical practice exist. High resolution tracking and imaging in vivo is one of the barriers that limit the use of micro- and nanorobots in clinical applications. Here, the inclusion of radioactive compounds in soft thermoresponsive magnetic microrobots is investigated to enable their single-photon emission computed tomography imaging. Four microrobotic platforms differing in hydrogel structure and four 99m Tc[Tc]-based radioactive compounds are investigated in order to achieve optimal contrast agent retention and optimal imaging. Single microrobot imaging of structures as low as 100 µm in diameter, as well as tracking of shape switching from tubular to planar configurations by inclusion of 99m Tc[Tc] colloid in the hydrogel structure, is reported.
Collapse
|
90
|
Xu Y, Hu X, Kundu S, Nag A, Afsarimanesh N, Sapra S, Mukhopadhyay SC, Han T. Silicon-Based Sensors for Biomedical Applications: A Review. SENSORS 2019; 19:s19132908. [PMID: 31266148 PMCID: PMC6651638 DOI: 10.3390/s19132908] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 06/27/2019] [Accepted: 06/27/2019] [Indexed: 01/20/2023]
Abstract
The paper highlights some of the significant works done in the field of medical and biomedical sensing using silicon-based technology. The use of silicon sensors is one of the pivotal and prolonged techniques employed in a range of healthcare, industrial and environmental applications by virtue of its distinct advantages over other counterparts in Microelectromechanical systems (MEMS) technology. Among them, the sensors for biomedical applications are one of the most significant ones, which not only assist in improving the quality of human life but also help in the field of microfabrication by imparting knowledge about how to develop enhanced multifunctional sensing prototypes. The paper emphasises the use of silicon, in different forms, to fabricate electrodes and substrates for the sensors that are to be used for biomedical sensing. The electrical conductivity and the mechanical flexibility of silicon vary to a large extent depending on its use in developing prototypes. The article also explains some of the bottlenecks that need to be dealt with in the current scenario, along with some possible remedies. Finally, a brief market survey is given to estimate a probable increase in the usage of silicon in developing a variety of biomedical prototypes in the upcoming years.
Collapse
|
91
|
Popova AA, Tronser T, Demir K, Haitz P, Kuodyte K, Starkuviene V, Wajda P, Levkin PA. Facile One Step Formation and Screening of Tumor Spheroids Using Droplet-Microarray Platform. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1901299. [PMID: 31058427 DOI: 10.1002/smll.201901299] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Indexed: 05/10/2023]
Abstract
Tumor spheroids or microtumors are important 3D in vitro tumor models that closely resemble a tumor's in vivo "microenvironment" compared to 2D cell culture. Microtumors are widely applied in the fields of fundamental cancer research, drug discovery, and precision medicine. In precision medicine tumor spheroids derived from patient tumor cells represent a promising system for drug sensitivity and resistance testing. Established and commonly used platforms for routine screenings of cell spheroids, based on microtiter plates of 96- and 384-well formats, require relatively large numbers of cells and compounds, and often lead to the formation of multiple spheroids per well. In this study, an application of the Droplet Microarray platform, based on hydrophilic-superhydrophobic patterning, in combination with the method of hanging droplet, is demonstrated for the formation of highly miniaturized single-spheroid-microarrays. Formation of spheroids from several commonly used cancer cell lines in 100 nL droplets starting with as few as 150 cells per spheroid within 24-48 h is demonstrated. Established methodology carries a potential to be adopted for routine workflows of high-throughput compound screening in 3D cancer spheroids or microtumors, which is crucial for the fields of fundamental cancer research, drug discovery, and precision medicine.
Collapse
|
92
|
Xu B, Zhu C, Qin L, Wei J, Yu Y. Light-Directed Liquid Manipulation in Flexible Bilayer Microtubes. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1901847. [PMID: 31062929 DOI: 10.1002/smll.201901847] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Indexed: 06/09/2023]
Abstract
Flexible microfluidic systems have potential in wearable and implantable medical applications. Directional liquid transportation in these systems typically requires mechanical pumps, gas tanks, and magnetic actuators. Herein, an alternative strategy is presented for light-directed liquid manipulation in flexible bilayer microtubes, which are composed of a commercially available supporting layer and the photodeformable layer of a newly designed azobenzene-containing linear liquid crystal copolymer. Upon moderate visible light irradiation, various liquid slugs confined in the flexible microtubes are driven in the preset direction over a long distance due to photodeformation-induced asymmetric capillary forces. Several light-driven prototypes of parallel array, closed-loop channel, and multiple micropump are established by the flexible bilayer microtubes to achieve liquid manipulation. Furthermore, an example of a wearable device attached to a finger for light-directed liquid motion is demonstrated in different gestures. These unique photocontrollable flexible microtubes offer a novel concept of wearable microfluidics.
Collapse
|
93
|
Pons-Faudoa FP, Ballerini A, Sakamoto J, Grattoni A. Advanced implantable drug delivery technologies: transforming the clinical landscape of therapeutics for chronic diseases. Biomed Microdevices 2019; 21:47. [PMID: 31104136 PMCID: PMC7161312 DOI: 10.1007/s10544-019-0389-6] [Citation(s) in RCA: 100] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Chronic diseases account for the majority of all deaths worldwide, and their prevalence is expected to escalate in the next 10 years. Because chronic disorders require long-term therapy, the healthcare system must address the needs of an increasing number of patients. The use of new drug administration routes, specifically implantable drug delivery devices, has the potential to reduce treatment-monitoring clinical visits and follow-ups with healthcare providers. Also, implantable drug delivery devices can be designed to maintain drug concentrations in the therapeutic window to achieve controlled, continuous release of therapeutics over extended periods, eliminating the risk of patient non-compliance to oral treatment. A higher local drug concentration can be achieved if the device is implanted in the affected tissue, reducing systemic adverse side effects and decreasing the challenges and discomfort of parenteral treatment. Although implantable drug delivery devices have existed for some time, interest in their therapeutic potential is growing, with a global market expected to reach over $12 billion USD by 2018. This review discusses implantable drug delivery technologies in an advanced stage of development or in clinical use and focuses on the state-of-the-art of reservoir-based implants including pumps, electromechanical systems, and polymers, sites of implantation and side effects, and deployment in developing countries.
Collapse
|
94
|
Parisi A, Van Hoey O, Mégret P, Vanhavere F. MICRODOSIMETRIC MODELING OF THE RELATIVE LUMINESCENCE EFFICIENCY OF LiF:Mg,Cu,P (MCP) DETECTORS EXPOSED TO CHARGED PARTICLES. RADIATION PROTECTION DOSIMETRY 2019; 183:172-176. [PMID: 30561684 DOI: 10.1093/rpd/ncy272] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 11/21/2018] [Indexed: 06/09/2023]
Abstract
Using a recently developed microdosimetric model based on the Monte Carlo code PHITS, the relative luminescence efficiency of LiF:Mg,Cu,P (MCP) thermoluminescent detectors to charged particles from 1H to 132Xe with energies from 3 to 1000 MeV/u has been assessed. The results have been compared with literature data showing very good agreement for particles from 12C to 132Xe in case of model calculations performed in a site size of 40 nm. For 1H and 4He ions, the model overestimates the experimental values by ~10%. An explanation of this deviation as a consequence of fading effects has been included.
Collapse
|
95
|
Holloway PM, Hallinan GI, Hegde M, Lane SIR, Deinhardt K, West J. Asymmetric confinement for defining outgrowth directionality. LAB ON A CHIP 2019; 19:1484-1489. [PMID: 30899932 DOI: 10.1039/c9lc00078j] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Directional connectivity is required to develop accurate in vitro models of the nervous system. This research investigated the interaction of murine neuronal outgrowths with asymmetric microstructured geometries to provide insights into the mechanisms governing unidirectional outgrowth bias. The structures were designed using edge-guidance and critical turning angle principles to study different prohibitive to permissive edge-guidance ratios. The different structures enable outgrowth in the permissive direction, while reducing outgrowth in the prohibitive direction. Outgrowth bias was probabilistic in nature, requiring multiple structures for effective unidirectional bias in primary hippocampal cultures at 14 days in vitro. Arrowhead structures with acute posterior corners were optimal, enabling 100% unidirectional outgrowth bias by virtue of re-routing and delay effects.
Collapse
|
96
|
Noren BE, Shaha RK, Stenquist AT, Frick CP, Oakey JS. Cell Printing in Complex Hydrogel Scaffolds. IEEE Trans Nanobioscience 2019; 18:265-268. [PMID: 30892231 DOI: 10.1109/tnb.2019.2905517] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Advancements in the microfabrication of soft materials have enabled the creation of increasingly sophisticated functional synthetic tissue structures for a myriad of tissue engineering applications. A challenge facing the field is mimicking the complex microarchitecture necessary to recapitulate proper morphology and function of many endogenous tissue constructs. This paper describes the creation of PEGDA hydrogel microenvironments (microgels) that maintain a high level of viability at single cell patterning scales and can be integrated into composite scaffolds with tunable modulus. PEGDA was stereolithographically patterned using a digital micromirror device to print single cell microgels at progressively decreasing length scales. The effect of feature size on cell viability was assessed and inert gas purging was introduced to preserve viability. A composite PEGDA scaffold created by this technique was mechanically tested and found to enable dynamic adjustability of the modulus. Together this approach advances the ability to microfabricate tissues that better mimic native constructs on cellular and subcellular length scales.
Collapse
|
97
|
Zheng YC, Zhao YY, Zheng ML, Chen SL, Liu J, Jin F, Dong XZ, Zhao ZS, Duan XM. Cucurbit[7]uril-Carbazole Two-Photon Photoinitiators for the Fabrication of Biocompatible Three-Dimensional Hydrogel Scaffolds by Laser Direct Writing in Aqueous Solutions. ACS APPLIED MATERIALS & INTERFACES 2019; 11:1782-1789. [PMID: 30608644 DOI: 10.1021/acsami.8b15011] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We have introduced a novel water-soluble two-photon photoinitiator based on the host-guest interaction between 3,6-bis[2-(1-methyl-pyridinium)vinyl]-9-pentyl-carbazole diiodide (BMVPC) and cucurbit[7]uril (CB7) because most of the commercial photoinitiators have poor two-photon initiating efficiency in aqueous solutions. The binding ratio of BMVPC and CB7 was determined as 1:1 by isothermal titration calorimetry and quantum chemical calculation. The formation of the host-guest complex increases the two-photon absorption cross-section about five times, and improves the water solubility required as the photoinitiator for hydrogel fabrication. The BMVPC-CB7 inclusion complex was used as the one-component photoinitiator, and the polyethylene glycol diacrylate with promising biocompatibility was used as the hydrogel monomer to form the aqueous-phase photoresist system applied to two-photon polymerization microfabrication. A relatively low laser threshold of 4.5 mW, a high fabricating resolution of 180 nm, and the true three-dimensional (3D) fabricating capability in the aqueous solution have been obtained by using the as-prepared photoresist system. Finally, 3D engineering hydrogel scaffold microstructures with low toxicity and good biocompatibility have been fabricated and cocultured with living HeLa cells, which demonstrates the potential for further application in tissue engineering.
Collapse
|
98
|
Srivastava SK, Clergeaud G, Andresen TL, Boisen A. Micromotors for drug delivery in vivo: The road ahead. Adv Drug Deliv Rev 2019; 138:41-55. [PMID: 30236447 DOI: 10.1016/j.addr.2018.09.005] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 08/27/2018] [Accepted: 09/11/2018] [Indexed: 01/16/2023]
Abstract
Autonomously propelled/externally guided micromotors overcome current drug delivery challenges by providing (a) higher drug loading capacity, (b) localized delivery (less toxicity), (c) enhanced tissue penetration and (d) active maneuvering in vivo. These microscale drug delivery systems can exploit biological fluids, as well as exogenous stimuli, like light-NIR, ultrasound and magnetic fields (or a combination of these), towards propulsion/drug release. Ability of these wireless drug carriers towards localized targeting and controlled drug release, makes them a lucrative candidate for drug administration in complex microenvironments (like solid tumors or gastrointestinal tract). In this report, we discuss these microscale drug delivery systems for their therapeutic benefits under in vivo setting and provide a design-application rationale towards greater clinical significance. Also, a proof-of-concept depicting 'microbots-in-a-capsule' towards oral drug delivery has been discussed.
Collapse
|
99
|
Yuan R, Nagarajan MB, Lee J, Voldman J, Doyle PS, Fink Y. Designable 3D Microshapes Fabricated at the Intersection of Structured Flow and Optical Fields. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1803585. [PMID: 30369043 DOI: 10.1002/smll.201803585] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Revised: 10/05/2018] [Indexed: 06/08/2023]
Abstract
3D structures with complex geometric features at the microscale, such as microparticles and microfibers, have promising applications in biomedical engineering, self-assembly, and photonics. Fabrication of complex 3D microshapes at scale poses a unique challenge; high-resolution methods such as two-photon-polymerization have print speeds too low for high-throughput production, while top-down approaches for bulk processing using microfabricated template molds have limited control of microstructure geometries over multiple axes. Here, a method for microshape fabrication is presented that combines a thermally drawn transparent fiber template with a masked UV-photopolymerization approach to enable biaxial control of microshape fabrication. Using this approach, high-resolution production of complex microshapes not producible using alternative methods is demonstrated, such as octahedrons, dreidels, and axially asymmetric fibers, at throughputs as high as 825 structures/minute. Finally, the fiber template is functionalized with conductive electrodes to enable hierarchical subparticle localization using dielectrophoretic forces.
Collapse
|
100
|
Shi J, Ma Y, Zhu J, Chen Y, Sun Y, Yao Y, Yang Z, Xie J. A Review on Electroporation-Based Intracellular Delivery. Molecules 2018; 23:E3044. [PMID: 30469344 PMCID: PMC6278265 DOI: 10.3390/molecules23113044] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 11/13/2018] [Accepted: 11/17/2018] [Indexed: 12/17/2022] Open
Abstract
Intracellular delivery is a critical step in biological discoveries and has been widely utilized in biomedical research. A variety of molecular tools have been developed for cell-based gene therapies, including FDA approved CAR-T immunotherapy, iPSC, cell reprogramming and gene editing. Despite the inspiring results of these applications, intracellular delivery of foreign molecules including nucleic acids and proteins remains challenging. Efficient yet non-invasive delivery of biomolecules in a high-throughput manner has thus long fascinates the scientific community. As one of the most popular non-viral technologies for cell transfection, electroporation has gone through enormous development with the assist of nanotechnology and microfabrication. Emergence of miniatured electroporation system brought up many merits over the weakness of traditional electroporation system, including precise dose control and high cell viability. These new generation of electroporation systems are of considerable importance to expand the biological applications of intracellular delivery, bypassing the potential safety issue of viral vectors. In this review, we will go over the recent progresses in the electroporation-based intracellular delivery and several potential applications of cutting-edge research on the miniatured electroporation, including gene therapy, cellular reprogramming and intracellular probe.
Collapse
|