101
|
Amadei F, Fröhlich B, Stremmel W, Tanaka M. Nonclassical Interactions of Phosphatidylcholine with Mucin Protect Intestinal Surfaces: A Microinterferometry Study. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:14046-14057. [PMID: 30359036 DOI: 10.1021/acs.langmuir.8b03035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Albeit many studies demonstrated that the accumulation of phospholipids in the intestinal mucosal surfaces is essential for the protection of colon epithelia against pathogenic bacteria, the mechanism of interactions between phospholipids and the surface protein mucin is not well understood. In this study, the significance of interfacial interactions between phospholipids and mucin proteins was quantified by the combination of an in vitro intestinal surface model and label-free microinterferometry. The model of intestinal surfaces consists of planar lipid membranes deposited on solid substrates (supported membranes) that display mucin proteins at defined surface densities. Following the quantitative characterization of the systems, we monitored the vertical fluctuation of 10 μm-large particles on model intestinal surfaces by using microinterferometry, and calculated the effective interfacial interaction potentials by analytically solving the Langevin equation. We found that the spring constant of interfacial potentials calculated based on a harmonic approximation increased concomitantly with the increase in surface potentials, indicating the dominant role of electrostatic interactions. Intriguingly, the spring constants of particles coated with phospholipids do not follow electrostatic interactions. The spring constant of particles coated with zwitterionic phosphatidylcholine was larger compared to membranes incorporating positively or negatively charged lipids. Our data suggested the presence of another underlying molecular level interaction, such as phosphocholine-saccharide interactions. The fact that phosphatidylcholine sustains the binding capability to enzymatically degraded mucin suggests that the direct delivery of phosphatidylcholine to the damaged mucus is a promising strategy for the better treatment of patients affected by inflammatory bowel diseases.
Collapse
|
102
|
Tang J, Wang J, Huang K, Ye Y, Su T, Qiao L, Hensley MT, Caranasos TG, Zhang J, Gu Z, Cheng K. Cardiac cell-integrated microneedle patch for treating myocardial infarction. SCIENCE ADVANCES 2018; 4:eaat9365. [PMID: 30498778 PMCID: PMC6261659 DOI: 10.1126/sciadv.aat9365] [Citation(s) in RCA: 155] [Impact Index Per Article: 25.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 10/26/2018] [Indexed: 05/17/2023]
Abstract
We engineered a microneedle patch integrated with cardiac stromal cells (MN-CSCs) for therapeutic heart regeneration after acute myocardial infarction (MI). To perform cell-based heart regeneration, cells are currently delivered to the heart via direct muscle injection, intravascular infusion, or transplantation of epicardial patches. The first two approaches suffer from poor cell retention, while epicardial patches integrate slowly with host myocardium. Here, we used polymeric MNs to create "channels" between host myocardium and therapeutic CSCs. These channels allow regenerative factors secreted by CSCs to be released into the injured myocardium to promote heart repair. In the rat MI model study, the application of the MN-CSC patch effectively augmented cardiac functions and enhanced angiomyogenesis. In the porcine MI model study, MN-CSC patch application was nontoxic and resulted in cardiac function protection. The MN system represents an innovative approach delivering therapeutic cells for heart regeneration.
Collapse
|
103
|
Park S, Lee Y, Kwon YM, Lee YT, Kim KH, Ko EJ, Jung JH, Song M, Graham B, Prausnitz MR, Kang SM. Vaccination by microneedle patch with inactivated respiratory syncytial virus and monophosphoryl lipid A enhances the protective efficacy and diminishes inflammatory disease after challenge. PLoS One 2018; 13:e0205071. [PMID: 30365561 PMCID: PMC6203256 DOI: 10.1371/journal.pone.0205071] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 09/18/2018] [Indexed: 01/01/2023] Open
Abstract
Intramuscular (IM) vaccination with formalin-inactivated respiratory syncytial virus (FI-RSV) failed in clinical trials due to vaccine-enhanced respiratory disease. To test the efficacy of skin vaccination against respiratory syncytial virus (RSV), we investigated the immunogenicity, efficacy, and inflammatory disease after microneedle (MN) patch delivery of FI-RSV vaccine (FI-RSV MN) to the mouse skin with or without an adjuvant of monophosphoryl lipid A (MPL). Compared to IM vaccination, MN patch delivery of FI-RSV was more effective in clearing lung viral loads and preventing weight loss, and in diminishing inflammation, infiltrating immune cells, and T helper type 2 (Th2) CD4 T cell responses after RSV challenge. With MPL adjuvant, MN patch delivery of FI-RSV significantly increased the immunogenicity and efficacy as well as preventing RSV disease as evidenced by lung viral clearance and avoiding pulmonary histopathology. Improved efficacy and prevention of disease by FI-RSV MN with MPL were correlated with no sign of airway resistance, lower levels of Th2 cytokines and infiltrating innate inflammatory cells, and higher levels of Th1 T cell responses into the lung. This study suggests that MN patch delivery of RSV vaccines to the skin with MPL adjuvant would be a promising vaccination method.
Collapse
|
104
|
Sumiyama K, Matsumoto N, Garçon-Yoshida J, Ukai H, Ueda HR, Tanaka Y. Easy and efficient production of completely embryonic-stem-cell-derived mice using a micro-aggregation device. PLoS One 2018; 13:e0203056. [PMID: 30231034 PMCID: PMC6145547 DOI: 10.1371/journal.pone.0203056] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Accepted: 08/14/2018] [Indexed: 01/09/2023] Open
Abstract
There is an increasing demand for genetically modified mice produced without crossing, for rapid phenotypic screening studies at the organismal level. For this purpose, generation of completely embryonic-stem-cell (ESC)-derived chimeric mice without crossing is now possible using a microinjection or aggregation method with 3i culture medium. However, the microinjection of ESCs into blastocyst, morula, or 8-cell-stage embryos requires a highly skilled operator. The aggregation method is an easier alternative, but the conventional aggregation protocol still requires special skills. To make the aggregation method easier and more precise, here we developed a micro-aggregation device. Unlike conventional 3-dimensional culture, which uses hanging-drop devices for aggregation, we fabricated a polystyrene funnel-like structure to smoothly drop ESCs into a small area (300-μm in diameter) at the bottom of the device. The bottom area was designed so that the surface tension of the liquid-air interface prevents the cells from falling. After aggregation, the cells can be recovered by simply exerting pressure on the liquid from the top. The microdevice can be set upon a regular 96-well plate, so it is compatible with multichannel pipette use or machine operation. Using the microdevice, we successfully obtained chimeric blastocysts, which when transplanted resulted in completely ESC-derived chimeric mice with high efficiency. By changing the number of ESCs in the aggregate, we found that the optimum number of co-cultured ESCs was around 90~120 per embryo. Under this condition, the efficiency of generating completely ESC-derived mice was the same or better than that of the injection method. These results indicated that our microdevice can be used to produce completely ESC-derived chimeric mice easily and with a high success rate, and thus represents a promising alternative to the conventional microinjection or aggregation method, especially for high-throughput, parallel experimental applications.
Collapse
|
105
|
Sun Y, Song W, Sun X, Zhang S. Inkjet-Printing Patterned Chip on Sticky Superhydrophobic Surface for High-Efficiency Single-Cell Array Trapping and Real-Time Observation of Cellular Apoptosis. ACS APPLIED MATERIALS & INTERFACES 2018; 10:31054-31060. [PMID: 30148358 DOI: 10.1021/acsami.8b10703] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Single-cell assays have broad applications in cellular studies, tissue engineering, fundamental studies of cell-cell interactions, and understanding of cell-to-cell variations. Most existing methods for micron-sized cell patterning are still based on lithography-based microfabrication process. Thus, exploiting new mask-free strategies while maintaining high-precision single-cell patterning is still a great challenge. Here, we presented a facile, low-cost, and mask-free approach for constructing high-resolution patterning on sticky superhydrophobic (SH) substrates based on inkjet printing with ordinary precision. In this work, the SH surface with both high contact angle and relatively high contact angle hysteresis can not only obtain high-resolution spots but also avoid droplets bouncing behavior. We improved the feature size of printed protein spots as small as 4 μm, which is much smaller than protein spots used for single-cell trapping. Moreover, with the assistance of a narrow microchannel, the inkjet-printing patterned chip with fibronectin ink allows for fast and high-efficiency trapping of multiple single-cell arrays. Using this method, single-cell occupancy could reach approximately 81% within 30 min on subcellular-sized patterning chip, and there was no significant effect on cell viability. As a proof of concept, this chip has been applied to study the real-time apoptosis of single cells and demonstrated the potential in cells' heterogeneity analysis.
Collapse
|
106
|
Ferguson CTJ, Al-Khalaf AA, Isaac RE, Cayre OJ. pH-responsive polymer microcapsules for targeted delivery of biomaterials to the midgut of Drosophila suzukii. PLoS One 2018; 13:e0201294. [PMID: 30091982 PMCID: PMC6084892 DOI: 10.1371/journal.pone.0201294] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 07/12/2018] [Indexed: 12/13/2022] Open
Abstract
Drosophila suzukii or spotted wing Drosophila is an economically important pest which can have a devastating impact on soft and stone fruit industries. Biological pesticides are being sought as alternatives to synthetic chemicals to control this invasive pest, but many are subject to degradation either in the environment or in the insect gut and as a result require protection. In this study we identified a sharp change in pH of the adult midgut from neutral to acidic (pH <3), which we then exploited to develop poly(2-vinylpyridine) (P2VP) microcapsules that respond to the change in midgut pH by dissolution and release of their cargo for uptake into the insect. First, we used labelled solid poly(methyl methacrylate) (PMMA) particles to show that microcapsules with a diameter less than 15 μm are readily ingested by the adult insect. To encapsulate water-soluble biological species in an aqueous continuous phase, a multiple emulsion template was used as a precursor for the synthesis of pH-responsive P2VP microcapsules with a fluorescent (FITC-dextran) cargo. The water-soluble agent was initially separated from the aqueous continuous phase by an oil barrier, which was subsequently polymerised. The P2VP microcapsules were stable at pH > 6, but underwent rapid dissolution at pH < 4.2. In vivo studies showed that the natural acidity of the midgut of D. suzukii also induced the breakdown of the responsive P2VP microcapsules to release FITC-dextran which was taken up into the body of the insect and accumulated in the renal tubules.
Collapse
|
107
|
Sun Z, Li C, Li L, Nie L, Dong Q, Li D, Gao L, Zang H. Study on feasibility of determination of glucosamine content of fermentation process using a micro NIR spectrometer. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 201:153-160. [PMID: 29747085 DOI: 10.1016/j.saa.2018.05.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 04/29/2018] [Accepted: 05/01/2018] [Indexed: 06/08/2023]
Abstract
N-acetyl-d-glucosamine (GlcNAc) is a microbial fermentation product, and NIR spectroscopy is an effective process analytical technology (PAT) tool in detecting the key quality attribute: the GlcNAc content. Meanwhile, the design of NIR spectrometers is under the trend of miniaturization, portability and low-cost nowadays. The aim of this study was to explore a portable micro NIR spectrometer with the fermentation process. First, FT-NIR spectrometer and Micro-NIR 1700 spectrometer were compared with simulated fermentation process solutions. The Rc2, Rp2, RMSECV and RMSEP of the optimal FT-NIR and Micro-NIR 1700 models were 0.999, 0.999, 3.226 g/L, 1.388 g/L and 0.999, 0.999, 1.821 g/L, 0.967 g/L. Passing-Bablok regression method and paired t-test results showed there were no significant differences between the two instruments. Then the Micro-NIR 1700 was selected for the practical fermentation process, 135 samples from 10 batches were collected. Spectral pretreatment methods and variables selection methods (BiPLS, FiPLS, MWPLS and CARS-PLS) for PLS modeling were discussed. The Rc2, Rp2, RMSECV and RMSEP of the optimal GlcNAc content PLS model of the practical fermentation process were 0.994, 0.995, 2.792 g/L and 1.946 g/L. The results have a positive reference for application of the Micro-NIR spectrometer. To some extent, it could provide theoretical supports in guiding the microbial fermentation or the further assessment of bioprocess.
Collapse
|
108
|
Szostak KM, Constandinou TG. Hermetic packaging for implantable microsystems: Effectiveness of sequentially electroplated AuSn alloy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:3849-3853. [PMID: 30441204 DOI: 10.1109/embc.2018.8513272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
With modern microtechnology, there is an aggressive miniaturization of smart devices, despite an increasing level of integration and overall complexity. It is therefore becoming increasingly important to be achieve reliable, compact packaging. For implantable medical devices (IMDs), the package must additionally provide a high quality hermetic environment to protect the device from the human body. For chip-scale devices, AuSn eutectic bonding offers the possibility of forming compact seals that achieve ultra-low permeability. A key feature is this can be achieved at process temperatures of below 350315°C, therefore allowing for the integration of sensors and microsystems with CMOS electronics within a single package. Issues however such as solder wetting, void formation and controlling composition make formation of high-quality repeatable seals highly challenging. Towards this aim, this paper presents our experimental work characterizing the eutectic stack deposition. We detail our designmethods and process flow, share our experiences in controlling electrochemical deposition of AuSn alloy and finally discuss usability of sequential electroplating process for the formation of hermetic eutectic bonds.
Collapse
|
109
|
Zamuruyev KO, Schmidt AJ, Borras E, McCartney MM, Schivo M, Kenyon NJ, Delplanque JP, Davis CE. Power-efficient self-cleaning hydrophilic condenser surface for portable exhaled breath condensate (EBC) metabolomic sampling. J Breath Res 2018; 12:036020. [PMID: 29771240 PMCID: PMC6015477 DOI: 10.1088/1752-7163/aac5a5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
In this work, we present a hydrophilic self-cleaning condenser surface for the collection of biological and environmental aerosol samples. The condenser is installed in a battery-operated hand-held breath sampling device. The device performance is characterized by the collection and analysis of exhaled breath samples from a group of volunteers. The exhaled breath condensate is collected on a subcooled condenser surface, transferred into a storage vial, and its chemical content is analyzed using mass spectrometric methods. The engineered surface supports upon it a continuous condensation cycle, and this allows the collection of liquid samples exceeding the saturation mass/area limit of a plain hydrophilic surface. The condenser surface employs two constituent parameters: a low surface energy barrier to enhance nucleation and condensation efficiency, and a network of surface microstructures to create a self-cleaning mechanism for fluid aggregation into a reservoir. Removal of the liquid condensate from the condenser surface prevents the formation of a thick liquid layer, and thus maintains a continuous condensation cycle with a minimum decrease in heat transfer efficiency as condensation occurs on the surface. The self-cleaning condenser surfaces may have a number of applications in the collection of biological, chemical, or environmental aerosol samples. Sample phase conversion to liquid can facilitate sample manipulation and chemical analysis of matrices with low concentrations. Here, we demonstrate the use of a self-cleaning microcondenser for the collection of exhaled breath condensate with a hand-held portable device. All breath collections with the two devices were performed with the same group of volunteers under UC Davis IRB protocol 63701-3.
Collapse
|
110
|
Jeon O, Lee K, Alsberg E. Spatial Micropatterning of Growth Factors in 3D Hydrogels for Location-Specific Regulation of Cellular Behaviors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1800579. [PMID: 29782703 PMCID: PMC6238642 DOI: 10.1002/smll.201800579] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 03/29/2018] [Indexed: 05/26/2023]
Abstract
Growth factors are potent stimuli for regulating cell function in tissue engineering strategies, but spatially patterning their presentation in 3D in a facile manner using a single material is challenging. Micropatterning is an attractive tool to modulate the cellular microenvironment with various biochemical and physical cues and study their effects on stem cell behaviors. Implementing heparin's ability to immobilize growth factors, dual-crosslinkable alginate hydrogels are micropatterned in 3D with photocrosslinkable heparin substrates with various geometries and micropattern sizes, and their capability to establish 3D micropatterns of growth factors within the hydrogels is confirmed. This 3D micropatterning method could be applied to various heparin binding growth factors, such as fibroblast growth factor-2, vascular endothelial growth factor, transforming growth factor-betas and bone morphogenetic proteins while retaining the hydrogel's natural degradability and cytocompability. Stem cells encapsulated within these micropatterned hydrogels have exhibited spatially localized growth and differentiation responses corresponding to various growth factor patterns, demonstrating the versatility of the approach in controlling stem cell behavior for tissue engineering and regenerative medicine applications.
Collapse
|
111
|
Lafond M, Watanabe A, Yoshizawa S, Umemura SI, Tachibana K. Cavitation-threshold Determination and Rheological-parameters Estimation of Albumin-stabilized Nanobubbles. Sci Rep 2018; 8:7472. [PMID: 29748624 PMCID: PMC5945894 DOI: 10.1038/s41598-018-25913-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 04/25/2018] [Indexed: 12/24/2022] Open
Abstract
Nanobubbles (NBs) are of high interest for ultrasound (US) imaging as contrast agents and therapy as cavitation nuclei. Because of their instability (Laplace pressure bubble catastrophe) and low sensitivity to US, reducing the size of commonly used microbubbles to submicron-size is not trivial. We introduce stabilized NBs in the 100-250-nm size range, manufactured by agitating human serum albumin and perfluoro-propane. These NBs were exposed to 3.34- and 5.39-MHz US, and their sensitivity to US was proven by detecting inertial cavitation. The cavitation-threshold information was used to run a numerical parametric study based on a modified Rayleigh-Plesset equation (with a Newtonian rheology model). The determined values of surface tension ranged from 0 N/m to 0.06 N/m. The corresponding values of dilatational viscosity ranged from 5.10-10 Ns/m to 1.10-9 Ns/m. These parameters were reported to be 0.6 N/m and 1.10-8 Ns/m for the reference microbubble contrast agent. This result suggests the possibility of using albumin as a stabilizer for the nanobubbles that could be maintained in circulation and presenting satisfying US sensitivity, even in the 3-5-MHz range.
Collapse
|
112
|
Moore D, Saraf RF. Simultaneous Printing of Two Inks by Contact Lithography. ACS APPLIED MATERIALS & INTERFACES 2018; 10:14193-14199. [PMID: 29617566 DOI: 10.1021/acsami.8b03038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Microcontact printing (μCP) is a valuable technique used to fabricate complex patterns on surfaces for applications such as sensors, cell seeding, self-assembled monolayers of proteins and nanoparticles, and micromachining. The process is very precise but is typically confined to depositing a single type of ink per print, which limits the complexity of using multifunctionality patterns. Here we describe a process by which two inks are printed concomitantly in a single operation to create an alternating pattern of hydrophobic and hydrophilic characteristics. The hydrophobic ink, PDMS, is deposited by evaporation on the noncontact region, while the hydrophilic polyelectrolyte is transferred on contact. We demonstrate that there is no gap between the two patterns using an optical-electrochemical method. We describe some potential applications of this method, including layer-by-layer deposition of polyelectrolytes for sensors and creation of a scaffold for cell culture.
Collapse
|
113
|
Selvaggi L, Pasakarnis L, Brunner D, Aegerter CM. Magnetic tweezers optimized to exert high forces over extended distances from the magnet in multicellular systems. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:045106. [PMID: 29716356 DOI: 10.1063/1.5010788] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Magnetic tweezers are mainly divided into two classes depending on the ability of applying torque or forces to the magnetic probe. We focused on the second category and designed a device composed by a single electromagnet equipped with a core having a special asymmetric profile to exert forces as large as 230 pN-2.8 μm Dynabeads at distances in excess of 100 μm from the magnetic tip. Compared to existing solutions our magnetic tweezers overcome important limitations, opening new experimental paths for the study of a wide range of materials in a variety of biophysical research settings. We discuss the benefits and drawbacks of different magnet core characteristics, which led us to design the current core profile. To demonstrate the usefulness of our magnetic tweezers, we determined the microrheological properties inside embryos of Drosophila melanogaster during the syncytial stage. Measurements in different locations along the dorsal-ventral axis of the embryos showed little variation, with a slight increase in cytoplasm viscosity at the periphery of the embryos. The mean cytoplasm viscosity we obtain by active force exertion inside the embryos is comparable to that determined passively using high-speed video microrheology.
Collapse
|
114
|
Liu Y, Ge D, Cong J, Piao HG, Huang X, Xu Y, Lu G, Pan L, Liu M. Magnetically Powered Annelid-Worm-Like Microswimmers. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1704546. [PMID: 29611296 DOI: 10.1002/smll.201704546] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 02/09/2018] [Indexed: 06/08/2023]
Abstract
A bioinspired magnetically powered microswimmer is designed and experimentally demonstrated by mimicking the morphology of annelid worms. The structural parameters of the microswimmer, such as the surface wrinkling, can be controlled by applying prestrain on substrate for the precise fabrication and consistent performance of the microswimmers. The resulting annelid-worm-like microswimmers display efficient propulsion under an oscillating magnetic field, reaching a peak speed of ≈100 µm s-1 . The speed and directionality of the microswimmer can be readily controlled by changing the parameters of the field inputs. Additionally, it is demonstrated that the microswimmers are able to transport microparticles toward a predefined destination, although the translation velocity is inevitably reduced due to the additional hydrodynamic resistance of the microparticles. These annelid-worm-like microswimmers have excellent mobility, good maneuverability, and strong transport capacity, and they hold considerable promise for diverse biomedical, chemical sensing, and environmental applications.
Collapse
|
115
|
Hu S, Chen TH, Zhao Y, Wang Z, Lam RHW. Protein-Substrate Adhesion in Microcontact Printing Regulates Cell Behavior. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:1750-1759. [PMID: 29304548 DOI: 10.1021/acs.langmuir.7b02935] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Microcontact printing (μCP) is widely used to create patterns of biomolecules essential for studies of cell mechanics, migration, and tissue engineering. However, different types of μCPs may create micropatterns with varied protein-substrate adhesion, which may change cell behaviors and pose uncertainty in result interpretation. Here, we characterize two μCP methods for coating extracellular matrix (ECM) proteins (stamp-off and covalent bond) and demonstrate for the first time the important role of protein-substrate adhesion in determining cell behavior. We found that, as compared to cells with weaker traction force (e.g., endothelial cells), cells with strong traction force (e.g., vascular smooth muscle cells) may delaminate the ECM patterns, which reduced cell viability as a result. Importantly, such ECM delamination was observed on patterns by stamp-off but not on the patterns by covalent bonds. Further comparisons of the displacement of the ECM patterns between the normal VSMCs and the force-reduced VSMCs suggested that the cell traction force plays an essential role in this ECM delamination. Together, our results indicated that μCPs with insufficient adhesion may lead to ECM delamination and cause cell death, providing new insight for micropatterning in cell-biomaterial interaction on biointerfaces.
Collapse
|
116
|
Bae JW, Kim HR. Feasibility and its characteristics of CO2 laser micromachining-based PMMA anti-scattering grid estimated by MCNP code simulation. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2018; 26:273-280. [PMID: 29154314 DOI: 10.3233/xst-17327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
BACKGROUND Anti-scattering grid has been used to improve the image quality. However, applying a commonly used linear or parallel grid would cause image distortion, and focusing grid also requires a precise fabrication technology, which is expensive. OBJECTIVE To investigate and analyze whether using CO2 laser micromachining-based PMMA anti-scattering grid can improve the performance of the grid at a lower cost. Thus, improvement of grid performance would result in improvement of image quality. METHODS The cross-sectional shape of CO2 laser machined PMMA is similar to alphabet 'V'. The performance was characterized by contrast improvement factor (CIF) and Bucky. Four types of grid were tested, which include thin parallel, thick parallel, 'V'-type and 'inverse V'-type of grid. RESULTS For a Bucky factor of 2.1, the CIF of the grid with both the "V" and inverse "V" had a value of 1.53, while the thick and thick parallel types had values of 1.43 and 1.65, respectively. CONCLUSION The 'V' shape grid manufacture by CO2 laser micromachining showed higher CIF than parallel one, which had same shielding material channel width. It was thought that the 'V' shape grid would be replacement to the conventional parallel grid if it is hard to fabricate the high-aspect-ratio grid.
Collapse
|
117
|
Luan Q, Cahoon S, Wu A, Bale SS, Yarmush M, Bhushan A. A microfluidic in-line ELISA for measuring secreted protein under perfusion. Biomed Microdevices 2017; 19:101. [PMID: 29128921 PMCID: PMC6335147 DOI: 10.1007/s10544-017-0244-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Recent progress in the development of microfluidic microphysiological systems such as 'organs-on-chips' and microfabricated cell culture is geared to simulate organ-level physiology. These tissue models leverage microengineering technologies that provide capabilities of presenting cultured cells with input signals in a more physiologically relevant context such as perfused flow. Proteins that are secreted from cells have important information about the health of the cells. Techniques to quantify cellular proteins include mass spectrometry to ELISA (enzyme-linked immunosorbent assay). Although our capability to perturb the cells in the microphysiological systems with varying inputs is well established, we lack the tools to monitor in-line the cellular responses. User intervention for sample collection and off-site is cumbersome, causes delays in obtaining results, and is especially expensive because of collection, storage, and offline processing of the samples, and in many case, technically impractical to carry out because of limitated sample volumes. To address these shortcomings, we report the development of an ELISA that is carried out in-line under perfusion within a microfluidic device. Using this assay, we measured the albumin secreted from perfused hepatocytes without and under stimulation by IL-6. Since the method is based on a sandwich ELISA, we envision broad application of this technology to not just organs-on-chips but also to characterizing the temporal release and measurement of soluble factors and response to drugs.
Collapse
|
118
|
Nakashima Y, Miyagi-Shiohira C, Kobayashi N, Saitoh I, Watanabe M, Noguchi H. A proteome analysis of pig pancreatic islets and exocrine tissue by liquid chromatography with tandem mass spectrometry. Islets 2017; 9:159-176. [PMID: 29099648 PMCID: PMC5710700 DOI: 10.1080/19382014.2017.1389826] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Liquid chromatography with tandem mass spectrometry (LC-MS/MS) is a proteome analysis method, and the shotgun analysis by LC-MS/MS comprehensively identifies proteins from tissues and cells with high resolving power. In this study, we analyzed the protein expression in pancreatic tissue by LC-MS/MS. Islets isolated from porcine pancreata (purity ≥95%) and exocrine tissue (purity ≥99%) were used in this study. LC-MS/MS showed that 13 proteins were expressed in pancreatic islets only (Group I), 43 proteins were expressed in both islets and exocrine tissue (Group I&E), and 102 proteins were expressed in exocrine tissue only (Group E). Proteins involved in islet differentiation and cell proliferation were identified in Group I (e.g. CLUS, CMGA, MIF). In addition, various functional proteins (e.g. SCG2, TBA1A) were identified in islet by using the new method of 'principal component analysis (PCA)'. However, the function of such proteins on islets remains unclear. EPCAM was identified in Group E. Group E was found to include proteins involved in clinical inflammatory diseases such as pancreatitis (e.g. CBPA1, CGL, CYTB, ISK1 and PA21B). Many of these identified proteins were reported less frequently in previous studies, and HS71B, NEC2, PRAF3 and SCG1 were newly detected in Group I while CPNS1, DPEP1, GANAB, GDIB, GGT1, HSPB1, ICTL, VILI, MUTA, NDKB, PTGR1, UCHL3, VAPB and VINC were newly detected in Group E. These results show that comprehensive expression analysis of proteins by LC-MS/MS is useful as a method to investigate new factors constructing cellular component, biological process, and molecular function.
Collapse
|
119
|
Maharbiz MM. Protein patterning using germanium as a sacrificial layer. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:1865-1868. [PMID: 29060254 DOI: 10.1109/embc.2017.8037210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
With the rise of microfluidic diagnostics, there is a need for more efficient methods of patterning surface-attached moieties, including proteins like antibodies, onto microchannel surfaces. This arises because almost all of the solvents and processes used for surface-attachment chemistries (or their payloads) are incompatible with sacrificial layers usually photoresist during microfabrication, rendering it difficult to easily pattern active chemistry onto a surface in manufacture scale. We present a simple method, based on thin film germanium dissolution, which is compatible with both modern nanolithographic techniques and surface chemistries. Simply, because germanium thin films dissolve readily, controllably and rapidly in water (but not organic solvents), these films can be used to mask and protect areas of the substrate during the attachment of surface chemistries. We demonstrate the process and results using microscale patterns. The resolution and alignment of this method depends on the photolithography tool used; nanoscale patterning is not difficult to achieve. In addition, we show that with non-conformal germanium deposition (e.g. e-beam evaporation), the conjugation of surface chemistry on vertical side walls can be manipulated by controlling the thickness of the deposited germanium layer, opening another dimension for microfluidic devices and cell manipulation research.
Collapse
|
120
|
Eslami Amirabadi H, SahebAli S, Frimat JP, Luttge R, den Toonder JMJ. A novel method to understand tumor cell invasion: integrating extracellular matrix mimicking layers in microfluidic chips by "selective curing". Biomed Microdevices 2017; 19:92. [PMID: 29038872 PMCID: PMC5644704 DOI: 10.1007/s10544-017-0234-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A major challenge in studying tumor cell invasion into its surrounding tissue is to identify the contribution of individual factors in the tumor microenvironment (TME) to the process. One of the important elements of the TME is the fibrous extracellular matrix (ECM) which is known to influence cancer cell invasion, but exactly how remains unclear. Therefore, there is a need for new models to unravel mechanisms behind the tumor-ECM interaction. In this article, we present a new microfabrication method, called selective curing, to integrate ECM-mimicking layers between two microfluidic channels. This method enables us to study the effect of 3D matrices with controlled architecture, beyond the conventionally used hydrogels, on cancer invasion in a controlled environment. As a proof of principle, we have integrated two electrospun Polycaprolactone (PCL) matrices with different fiber diameters in one chip. We then studied the 3D migration of MDA-MB-231 breast cancer cells into the matrices under the influence of a chemotactic gradient. The results show that neither the invasion distance nor the general cell morphology is affected significantly by the difference in fiber size of these matrices. The cells however do produce longer and more protrusions in the matrix with smaller fiber size. This microfluidic system enables us to study the influence of other factors in the TME on cancer development as well as other biological applications as it provides a controlled compartmentalized environment compatible with cell culturing.
Collapse
|
121
|
Abstract
Liquid droplets are very simple objects present in our everyday life. They are extremely important for many natural phenomena as well as for a broad variety of industrial processes. The conventional research areas in which the droplets are studied include physical chemistry, fluid mechanics, chemical engineering, materials science, and micro- and nanotechnology. Typical studies include phenomena such as condensation and droplet formation, evaporation of droplets, or wetting of surfaces. The present article reviews the recent literature that employs droplets as animated soft matter. It is argued that droplets can be considered as liquid robots possessing some characteristics of living systems, and such properties can be applied to unconventional computing through maze solving or operation in logic gates. In particular, the lifelike properties and behavior of liquid robots, namely (i) movement, (ii) self-division, and (iii) group dynamics, will be discussed.
Collapse
|
122
|
Kim YS, Lu J, Shih B, Gharibans A, Zou Z, Matsuno K, Aguilera R, Han Y, Meek A, Xiao J, Tolley MT, Coleman TP. Scalable Manufacturing of Solderable and Stretchable Physiologic Sensing Systems. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2017; 29:1701312. [PMID: 28837756 DOI: 10.1002/adma.201701312] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Revised: 05/13/2017] [Indexed: 06/07/2023]
Abstract
Methods for microfabrication of solderable and stretchable sensing systems (S4s) and a scaled production of adhesive-integrated active S4s for health monitoring are presented. S4s' excellent solderability is achieved by the sputter-deposited nickel-vanadium and gold pad metal layers and copper interconnection. The donor substrate, which is modified with "PI islands" to become selectively adhesive for the S4s, allows the heterogeneous devices to be integrated with large-area adhesives for packaging. The feasibility for S4-based health monitoring is demonstrated by developing an S4 integrated with a strain gauge and an onboard optical indication circuit. Owing to S4s' compatibility with the standard printed circuit board assembly processes, a variety of commercially available surface mount chip components, such as the wafer level chip scale packages, chip resistors, and light-emitting diodes, can be reflow-soldered onto S4s without modifications, demonstrating the versatile and modular nature of S4s. Tegaderm-integrated S4 respiration sensors are tested for robustness for cyclic deformation, maximum stretchability, durability, and biocompatibility for multiday wear time. The results of the tests and demonstration of the respiration sensing indicate that the adhesive-integrated S4s can provide end users a way for unobtrusive health monitoring.
Collapse
|
123
|
Huang YC, Huang PT, Wu SL, Hu YC, You YH, Chen JM, Huang YY, Chang HC, Lin YH, Duann JR, Chiu TW, Hwang W, Chen KN, Chuang CT, Chiou JC. Ultrahigh-Density 256-Channel Neural Sensing Microsystem Using TSV-Embedded Neural Probes. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:1013-1025. [PMID: 28371785 DOI: 10.1109/tbcas.2017.2669439] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Highly integrated neural sensing microsystems are crucial to capture accurate signals for brain function investigations. In this paper, a 256-channel neural sensing microsystem with a sensing area of 5 × 5 mm 2 is presented based on 2.5-D through-silicon-via (TSV) integration. This microsystem composes of dissolvable μ-needles, TSV-embedded μ-probes, 256-channel neural amplifiers, 11-bit area-power-efficient successive approximation register analog-to-digital converters, and serializers. This microsystem can detect 256 electrocorticography and local field potential signals within a small area of 5 mm × 5 mm. The neural amplifier realizes 57.8 dB gain with only 9.8 μW per channel. The overall power of this microsystem is only 3.79 mW for 256-channel neural sensing. A smaller microsystem with dimension of 6 mm × 4 mm has been also implanted into rat brain for somatosensory evoked potentials (SSEPs) recording by using contralateral and ipsilateral electrical stimuli with intensity from 0.2 to 1.0 mA, and successfully observed different SSEPs from left somatosensory cortex of a rat.
Collapse
|
124
|
Semnani D, Afrashi M, Alihosseini F, Dehghan P, Maherolnaghsh M. Investigating the performance of drug delivery system of fluconazole made of nano-micro fibers coated on cotton/polyester fabric. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:175. [PMID: 28956211 DOI: 10.1007/s10856-017-5957-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2016] [Accepted: 08/03/2017] [Indexed: 06/07/2023]
Abstract
Polymer-based drug delivery systems are suitable to optimize the therapeutic properties of drugs and to render them safer, more effective and reliable. Long-term or repeated use of oral administration of fluconazole for treating chronic candidiasis in the patient and partially abandoned treatment lead to the resistant strains of the fungus Candida albicans and severity of the disease. In this study, the use of nanofibers and microfibers containing fluconazole for local drug delivery to increase the efficiencies and reduce the side effects caused by taking the drug was studied. Morphology, microstructure and chemical composition of PVA nanofibers containing fluconazole were characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). As well as, the DSC test was indicated presence of fluconazole in PVA fibrous mats. The rate of drug release was investigated by UV-Vis spectrophotometery and swelling technique. SEM images showed that the nanofibers with uniform structure without beads were produced. The mechanical properties of the pristine PVA nanofiber and fibrous mat containing drug were evaluated. The release of fluconazole from PVA nanofibers in pH of 7.4 and at 37 °C was investigated. The results presented that the drug release rate is dependent on the morphology and structure of PVA nanofibers and could be adjusted in desired dosage. The presented products are applicable in the high production form for medical textile industry.
Collapse
|
125
|
Pires LR, Lopes CDF, Salvador D, Rocha DN, Pêgo AP. Ibuprofen-loaded fibrous patches-taming inhibition at the spinal cord injury site. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:157. [PMID: 28894995 DOI: 10.1007/s10856-017-5967-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 08/19/2017] [Indexed: 06/07/2023]
Abstract
It is now widely accepted that a therapeutic strategy for spinal cord injury (SCI) demands a multi-target approach. Here we propose the use of an easily implantable bilayer polymeric patch based on poly(trimethylene carbonate-co-ε-caprolactone) (P(TMC-CL)) that combines physical guidance cues provided by electrospun aligned fibres and the delivery of ibuprofen, as a mean to reduce the inhibitory environment at the lesion site by taming RhoA activation. Bilayer patches comprised a solvent cast film onto which electrospun aligned fibres have been deposited. Both layers were loaded with ibuprofen. In vitro release (37°C, in phosphate buffered saline) of the drug from the loaded scaffolds under sink condition was found to occur in the first 24 h. The released ibuprofen was shown to retain its bioactivity, as indicated by the reduction of RhoA activation when the neuronal-like cell line ND7/23 was challenged with lysophosphatidic acid. Ibuprofen-loaded P(TMC-CL) bilayer scaffolds were successfully implanted in vivo in a dorsal hemisection rat SCI model mediating the reduction of RhoA activation after 5 days of implantation in comparison to plain P(TMC-CL) scaffolds. Immunohistochemical analysis of the tissue shows βIII tubulin positive cells close to the ibuprofen-loaded patches further supporting the use of this strategy in the context of regeneration after a lesion in the spinal cord.
Collapse
|