101
|
Mostafa IM, Omar MA, Ahmed Elsayed M, Almaghrabi M, Mohamed AA. Green and inventive fluorescence approach for levodropropizine determination in human plasma. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 312:124060. [PMID: 38402704 DOI: 10.1016/j.saa.2024.124060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/13/2024] [Accepted: 02/18/2024] [Indexed: 02/27/2024]
Abstract
A green, rapid and sensitive fluorimetric method to quantify levodropropizine (LVP) in human plasma was exploited for the first time. The proposed method adopts LVP's intrinsic fluorescence in distilled water at a detecting emission of 345 nm following excitation at 240 nm. LVP displayed linearity across concentrations ranging from 50 to 1000 ng mL-1, with a detection limit of 0.77 ng mL-1 and a quantification limit of 2.33 ng mL-1. Thorough validation confirmed its reliability, successfully determining LVP in tablets with an average recovery of 98.64 ± 1.07 %. Furthermore, the method's applicability extended to estimate the studied drug in spiked human plasma with excellent obtained percentage recoveries (98.68 ± 1.28-100.14 ± 1.23).
Collapse
|
102
|
Saadatidizaji Z, Sohrabi N, Mohammadi R. Development of a simple polymer-based sensor for detection of the Pirimicarb pesticide. Sci Rep 2024; 14:10293. [PMID: 38704412 PMCID: PMC11069528 DOI: 10.1038/s41598-024-60748-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 04/26/2024] [Indexed: 05/06/2024] Open
Abstract
In this study, a sensitive and selective fluorescent chemosensor was developed for the determination of pirimicarb pesticide by adopting the surface molecular imprinting approach. The magnetic molecularly imprinted polymer (MIP) nanocomposite was prepared using pirimicarb as the template molecule, CuFe2O4 nanoparticles, and graphene quantum dots as a fluorophore (MIP-CuFe2O4/GQDs). It was then characterized using X-ray diffraction (XRD) technique, Fourier transforms infrared (FT-IR) spectroscopy, scanning electron microscope (SEM), and transmission electron microscopy (TEM). The response surface methodology (RSM) was also employed to optimize and estimate the effective parameters of pirimicarb adsorption by this polymer. According to the experimental results, the average particle size and imprinting factor (IF) of this polymer are 53.61 nm and 2.48, respectively. Moreover, this polymer has an excellent ability to adsorb pirimicarb with a removal percentage of 99.92 at pH = 7.54, initial pirimicarb concentration = 10.17 mg/L, polymer dosage = 840 mg/L, and contact time = 6.15 min. The detection of pirimicarb was performed by fluorescence spectroscopy at a concentration range of 0-50 mg/L, and a sensitivity of 15.808 a.u/mg and a limit of detection of 1.79 mg/L were obtained. Real samples with RSD less than 2 were measured using this chemosensor. Besides, the proposed chemosensor demonstrated remarkable selectivity by checking some other insecticides with similar and different molecular structures to pirimicarb, such as diazinon, deltamethrin, and chlorpyrifos.
Collapse
|
103
|
Nguyen SH, Nguyen VN, Tran MT. Dual-channel fluorescent sensors based on chitosan-coated Mn-doped ZnS micromaterials to detect ampicillin. Sci Rep 2024; 14:10066. [PMID: 38698009 PMCID: PMC11065863 DOI: 10.1038/s41598-024-59772-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 04/15/2024] [Indexed: 05/05/2024] Open
Abstract
The global threat of antibiotic resistance has increased the importance of the detection of antibiotics. Conventional methods to detect antibiotics are time-consuming and require expensive specialized equipment. Here, we present a simple and rapid biosensor for detecting ampicillin, a commonly used antibiotic. Our method is based on the fluorescent properties of chitosan-coated Mn-doped ZnS micromaterials combined with the β-lactamase enzyme. The biosensors exhibited the highest sensitivity in a linear working range of 13.1-72.2 pM with a limit of detection of 8.24 pM in deionized water. In addition, due to the biological specificity of β-lactamase, the proposed sensors have demonstrated high selectivity over penicillin, tetracycline, and glucose through the enhancing and quenching effects at wavelengths of 510 nm and 614 nm, respectively. These proposed sensors also showed promising results when tested in various matrices, including tap water, bottled water, and milk. Our work reports for the first time the cost-effective (Mn:ZnS)Chitosan micromaterial was used for ampicillin detection. The results will facilitate the monitoring of antibiotics in clinical and environmental contexts.
Collapse
|
104
|
Chen H, Huang H, Xu H, Wu T, Xu Y, Ma X, Yi W, Chen G, Huang S, Ouyang G. Pore-Engineered Hydrogen-Bonded Supramolecular Fluorosensor for Ultrasensitive Determination of Copper Ions. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2308716. [PMID: 38072769 DOI: 10.1002/smll.202308716] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 11/16/2023] [Indexed: 05/18/2024]
Abstract
The selective quantification of copper ions (Cu2+) in biosamples holds great importance for disease diagnosis, treatment, and prognosis since the Cu2+ level is closely associated with the physiological state of the human body. While it remains a long-term challenge due to the extremely low level of free Cu2+ and the potential interference by the complex matrices. Here, a pore-engineered hydrogen-bonded organic framework (HOF) fluorosensor is constructed enabling the ultrasensitive and highly selective detection of free Cu2+. Attributing to atomically precise functionalization of active amino "arm" within the HOF pores and the periodic π-conjugated skeleton, this porous HOF fluorosensor affords high affinity toward Cu2+ through double copper-nitrogen (Cu─N) coordination interactions, resulting in specific fluorescence quenching of the HOF as compared with a series of substances ranging from other metal ions, metabolites, amino acids to proteins. Such superior fluorescence quenching effect endows the Cu2+ quantification by this new HOF sensor with a wide linearity of 50-20 000 nm, a low detection limit of 10 nm, and good recoveries (89.5%-115%) in human serum matrices, outperforming most of the reported approaches. This work highlights the practicability of hydrogen-bonded supramolecular engineering for designing facile and ultrasensitive biosensors for clinical free Cu2+ determination.
Collapse
|
105
|
Ghosh S, Ghosh S, Ranjan Dhara S, Baildya N, Ghosh K. Naphthalimide-based new architecture for fluorescence turn-on sensing of Cu 2+ and colorimetric detection of F -/CN . Methods 2024; 225:13-19. [PMID: 38438060 DOI: 10.1016/j.ymeth.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 02/16/2024] [Accepted: 02/29/2024] [Indexed: 03/06/2024] Open
Abstract
A new molecular structure 1 has been developed on naphthalimide motif. The amine and triazole binding groups have been employed at the 4-position of naphthalimide to explore the sensing behavior of molecule 1. Single crystal x-ray diffraction and other spectroscopic techniques confirm the identity of 1. Compound 1 exhibits high selectivity and sensitivity for Cu2+ ions in CH3CN. The binding of Cu2+ shows ∼ 70-fold enhancement in emission at 520 nm. The binding follows 1:1 interaction and the detection limit is determined to be 6.49 × 10-7 M. The amine-triazole binding site in 1 also corroborates the detection of F- through a colour change in CH3CN. Initially H-bonding and then deprotonation of amine -NH- in the presence of F- are the sequential steps involved in F- recognition with a detection limit of 4.13 × 10-7 M. Compound 1 is also sensible to CN- like F- ion and they are distinguished by Fe3+ ion. Cu2+-ensemble of 1 fluorimetrically recognizes F- among the tested anions and vice-versa. The collaborative effect of amine and triazole motifs in the binding of both Cu2+ and F-/CN- has been explained by DFT calculation.
Collapse
|
106
|
Sebastian D, Ramakrishnan K. A coumarin-modified graphene quantum dot-based luminogen for the detection of cysteine in aqueous media. Photochem Photobiol 2024; 100:549-560. [PMID: 37960981 DOI: 10.1111/php.13875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 09/26/2023] [Accepted: 10/16/2023] [Indexed: 11/15/2023]
Abstract
A biocompatible fluorescence sensor for cysteine detection receives wide appreciation recently, because of its importance in the medical field. Functionalized graphene quantum dots (GQDs) are recently emerging biocompatible quantum dots, which are considered as suitable candidates for biomolecule detection. Motivated by this concept, here we have developed a versatile fluorescent probe based on 3-aminocoumarin (AMC) functionalized GQDs for the detection of cysteine (Cys). Modification on GQD with AMC resulted in a stable fluorescent probe with an enhancement in quantum yield of about 84% and 40 nm redshift in emission peak compared with bare GQD. The modified GQD is then used for the sensitive and selective detection of cysteine in aqueous media. The detection of Cys within the linear range of 50 nM to 1.5 μM was achieved with a detection limit (LOD) of 0.86 nM. Here, the AMC-GQD exhibit a turn-off fluorescence sensing behavior. The quenching mechanism was also explored. The sensing process follows dynamic quenching mechanism, which is attributed to the photoinduced charge transfer from AMC-GQD to Cys. The Stern-Volmer plot, energy-level alignment obtained from cyclic voltammetry measurements and density functional theory predictions give a valid proof for this. Furthermore, the sensor was applied efficiently to the determination of Cys in real water samples.
Collapse
|
107
|
Tian D, Qi X, Seididamyeh M, Zhang H, Phan A, Zhang Z, Geng X, Sultanbawa Y, Zhang R. A ratiometric fluorescence probe for bisulfite detection in live cells and meat samples. Methods 2024; 225:100-105. [PMID: 38565390 DOI: 10.1016/j.ymeth.2024.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/14/2024] [Accepted: 03/30/2024] [Indexed: 04/04/2024] Open
Abstract
The development of reliable probe technology for the detection of bisulfite (HSO3-) in situ in food and biological samples is contributing significantly to food quality and safety assurance as well as community health. In this work, a responsive probe, EHDI, is developed for ratiometric fluorescence detection of HSO3- in aqueous solution, meat samples, and living cells. The probe is designed based on the HSO3- triggered 1,4-addition of electron deficit C = C bond of EHDI. As a result of this specific 1,4-addition, the π-conjugation system was destructed, resulting in blue shifts of the emission from 687 to 440 nm and absorption from 577 to 355 nm. The probe has good water solubility, high sensitivity and selectivity, allowing it to be used for imaging of HSO3- internalization and production endogenously. The capability of probe EHDI for HSO3- was then validated by traditional HPLC technology, enabling accurately detect HSO3- in beef samples. The successful development of this probe thus offers a new tool for investigating HSO3- in situ in food and biological conditions.
Collapse
|
108
|
Wang M, Zheng X, Yangcuo Z, Zhang S, Xie L, Cai Q. A novel synchronous fluorescence spectrometry combined with fluorescence sensitization for the highly sensitive and simultaneous detection of enoxacin, ofloxacin and tetracycline hydrochloride residues in wastewater. Talanta 2024; 271:125707. [PMID: 38280265 DOI: 10.1016/j.talanta.2024.125707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/12/2024] [Accepted: 01/22/2024] [Indexed: 01/29/2024]
Abstract
The synergistic effect of sodium dodecyl sulfate (SDS) and Mg2+ could significantly enhance the fluorescence intensity of enoxacin (ENO) at λex/λem = 269.2 nm/385.6 nm, ofloxacin (OFL) at λex/λem = 290.8 nm/466.2 nm and tetracycline hydrochloride (TCH) at λex/λem = 372.6 nm/514.8 nm. Moreover, when the wavelength difference (Δλ) was chosen 135 nm, the synchronous fluorescence spectra of the three antibiotic complexes could be well separated and the interference of the samples matrix were eliminated primely. Therefore, only one synchronous fluorescence scan was needed to simultaneously determine the three antibiotics. Based on these facts, a synchronous fluorescence spectrometry combining fluorescence sensitization for highly sensitive and selective determination of ENO, OFL and TCH residues in wastewater was developed for the first time. The experimental results showed that the concentrations of ENO, OFL and TCH in the range of 0.5-550 ng mL-1, 1-1500 ng mL-1 and 10-5500 ng mL-1 showed a good linear relationship with fluorescence intensity. The limits of detection were 0.0599 ng mL-1, 0.115 ng mL-1 and 0.151 ng mL-1, respectively. The recoveries of the actual sample were 87.50%-99.99 %, 93.00%-98.50 % and 85.70%-98.42 %, respectively. Overall, the novel synchronous fluorescence spectrometry established in the experiment has the advantages of high sensitivity, good selectivity, fast detection speed and high accuracy. It has been successfully applied to the detection of residual amounts of ENO, OFL and TCH in wastewater with satisfactory results.
Collapse
|
109
|
Mohagheghpour E, Farzin L, Sadjadi S. Alendronate-Functionalized Graphene Quantum Dots as an Effective Fluorescent Sensing Platform for Arsenic Ion Detection. Biol Trace Elem Res 2024; 202:2391-2401. [PMID: 37597070 DOI: 10.1007/s12011-023-03819-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 08/16/2023] [Indexed: 08/21/2023]
Abstract
Alendronate-functionalized graphene quantum dots (ALEN-GQDs) with a quantum yield of 57% were synthesized via a two-step route: preparation of graphene quantum dots (GQDs) by pyrolysis method using citric acid as the carbon source and post functionalization of GQDs via a hydrothermal method with alendronate sodium. After careful characterization of the obtained ALEN-GQDs, they were successfully employed as sensing materials with superior selectivity and sensitivity for the detection of nanomolar levels of arsenic ions (As(III)). According to the mechanistic investigation, arsenic ions can quench the fluorescence intensity of ALEN-GQDs through metal-ligand interaction between the As(III) ions and the surface functional groups of the fluorescent probe. This probe provided a rapid method to monitor As(III) with a wide detection range (44 nM-1.30 µM) and a low detection limit of 13 nM. Finally, to validate the applicability, this novel fluorescent probe was successfully applied for the quantitative determination of As(III) in rice and water samples.
Collapse
|
110
|
Magdy G, Elmansi H, Shabana RA, El-Enany N. A sustainable sensitive spectrofluorimetric approach for the determination of the multipotent protein lactoferrin in different pharmaceuticals and infant milk formula: Compliance with greenness metrics. LUMINESCENCE 2024; 39:e4772. [PMID: 38712470 DOI: 10.1002/bio.4772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Revised: 04/09/2024] [Accepted: 04/25/2024] [Indexed: 05/08/2024]
Abstract
The current study presents the first spectrofluorimetric approach for the estimation of lactoferrin, depending on the measurement of its native fluorescence at 337 nm after excitation at 230 nm, without the need for any hazardous chemicals or reagents. It was found that the fluorescence intensity versus concentration calibration plot was linear over the concentration range of 0.1-10.0 μg/mL with quantitation and detection limits of 0.082 and 0.027 μg/mL, respectively. The method was accordingly validated according to the ICH recommendations. The developed method was applied for the estimation of lactoferrin in different dosage forms, including capsules and sachets with high percent recoveries (97.84-102.53) and low %RSD values (<1.95). Lactoferrin is one of the key nutrients in milk powder and a significant nutritional fortifier. In order to assess the quality of milk powder, it is essential to rapidly and accurately quantify the lactoferrin content of the product. Therefore, the presented study was successfully applied for the selective estimation of lactoferrin in milk powder with acceptable percent recoveries (96.45-104.92) and %RSD values (≤3.607). Finally, the green profile of the method was estimated using two assessment tools: Green Analytical Procedure Index (GAPI) and Analytical GREEnness (AGREE), which demonstrated its excellent greenness.
Collapse
|
111
|
Igwe CL, Müller DF, Gisperg F, Pauk JN, Kierein M, Elshazly M, Klausser R, Kopp J, Spadiut O, Přáda Brichtová E. Online monitoring of protein refolding in inclusion body processing using intrinsic fluorescence. Anal Bioanal Chem 2024; 416:3019-3032. [PMID: 38573344 PMCID: PMC11045631 DOI: 10.1007/s00216-024-05249-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/06/2024] [Accepted: 03/08/2024] [Indexed: 04/05/2024]
Abstract
Inclusion bodies (IBs) are protein aggregates formed as a result of overexpression of recombinant protein in E. coli. The formation of IBs is a valuable strategy of recombinant protein production despite the need for additional processing steps, i.e., isolation, solubilization and refolding. Industrial process development of protein refolding is a labor-intensive task based largely on empirical approaches rather than knowledge-driven strategies. A prerequisite for knowledge-driven process development is a reliable monitoring strategy. This work explores the potential of intrinsic tryptophan and tyrosine fluorescence for real-time and in situ monitoring of protein refolding. In contrast to commonly established process analytical technology (PAT), this technique showed high sensitivity with reproducible measurements for protein concentrations down to 0.01 g L- 1 . The change of protein conformation during refolding is reflected as a shift in the position of the maxima of the tryptophan and tyrosine fluorescence spectra as well as change in the signal intensity. The shift in the peak position, expressed as average emission wavelength of a spectrum, was correlated to the amount of folding intermediates whereas the intensity integral correlates to the extent of aggregation. These correlations were implemented as an observation function into a mechanistic model. The versatility and transferability of the technique were demonstrated on the refolding of three different proteins with varying structural complexity. The technique was also successfully applied to detect the effect of additives and process mode on the refolding process efficiency. Thus, the methodology presented poses a generic and reliable PAT tool enabling real-time process monitoring of protein refolding.
Collapse
|
112
|
Sun L, Zhou Z, Wu Y, Meng Z, Huang H, Li T, Wang Z, Yang Y. A novel colormetric and light-up fluorescent sensor from flavonol derivative grafted cellulose for rapid and sensitive detection of Hg 2+ and its applications in biological and environmental system. Int J Biol Macromol 2024; 266:131209. [PMID: 38565364 DOI: 10.1016/j.ijbiomac.2024.131209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 03/18/2024] [Accepted: 03/26/2024] [Indexed: 04/04/2024]
Abstract
Mercury ion (Hg2+) is one of harmful heavy metal ions that can accumulate inside the human organism and cause some health problems. In the article, a highly effective fluorescent probe named EC-T-PCBM was prepared by grafting flavonol derivatives onto ethyl cellulose for the specific recognition of Hg2+. EC-T-PCBM exhibited a remarkable fluorescence light-up response toward Hg2+ with excellent sensitivity. EC-T-PCBM possessed several prominent sensing properties for Hg2+, such as low detection limit (43.9 nM), short response time (5 min), and wide detection pH range (6-9). The response mechanism of EC-T-PCBM to Hg2+ has been verified through 1H NMR titration and DFT computation. Additionally, EC-T-PCBM not only can be used for accurately determining trace amount of Hg2+ in actual environmental water samples, but also can serve as a portable and rapid device by loading it on test strips for sensitive and selective visualization of Hg2+. More importantly, the confocal fluorescence imaging of onion cells suggested the favorable cell membrane permeability of EC-T-PCBM and its prominent ability to continuously monitor the enrichment from Hg2+ within fresh plant tissues.
Collapse
|
113
|
Mousavizadegan M, Hosseini M, Sheikholeslami MN, Ganjali MR. A fluorescent sensor array based on antibiotic-stabilized metal nanoclusters for the multiplex detection of bacteria. Mikrochim Acta 2024; 191:293. [PMID: 38691169 DOI: 10.1007/s00604-024-06374-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/19/2024] [Indexed: 05/03/2024]
Abstract
To address the need for facile, rapid detection of pathogens in water supplies, a fluorescent sensing array platform based on antibiotic-stabilized metal nanoclusters was developed for the multiplex detection of pathogens. Using five common antibiotics, eight different nanoclusters (NCs) were synthesized including ampicillin stabilized copper NCs, cefepime stabilized gold and copper NCs, kanamycin stabilized gold and copper NCs, lysozyme stabilized gold NCs, and vancomycin stabilized gold/silver and copper NCs. Based on the different interaction of each NC with the bacteria strains, unique patterns were generated. Various machine learning algorithms were employed for pattern discernment, among which the artificial neural networks proved to have the highest performance, with an accuracy of 100%. The developed prediction model performed well on an independent test dataset and on real samples gathered from drinking water, tap water and the Anzali Lagoon water, with prediction accuracy of 96.88% and 95.14%, respectively. This work demonstrates how generic antibiotics can be implemented for NC synthesis and used as recognition elements for pathogen detection. Furthermore, it displays how merging machine learning techniques can elevate sensitivity of analytical devices.
Collapse
|
114
|
Nie P, Gao X, Yang X, Zhang Y, Lu H, Wang H, Zheng Z, Shen Y. AIE fluorogen-based oxidase-like fluorescence nanozyme-integrated smartphone for monitoring the freshness authenticity of soy products. Food Chem 2024; 439:138122. [PMID: 38070231 DOI: 10.1016/j.foodchem.2023.138122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 11/17/2023] [Accepted: 11/29/2023] [Indexed: 01/10/2024]
Abstract
Food safety concerns about the authenticity of soy product freshness have increased due to high demand from public. Developing an accurate and convenient monitoring method for freshness authenticity is crucial for safeguarding food safety. From this motive, this study employed PtPd NPs to encapsulate tetraphenylethylene (TPE) for engineering an AIE-based fluorescent nanozyme (PtPd NPs@TPE) with oxidase-like activity, achieving the ratiometric fluorescence monitoring of putrescine (PUT) to judge the freshness authenticity of soy products. In this design, PUT acted as an antioxidant and inhibited the oxidation process of PtPd NPs@TPE to o-phenylenediamine (OPD), leading to the reduction of oxidative product 2,3-diaminophenothiazine (DAP) alone with the weaken of yellow fluorescence from DAP at 552 nm and bright of bule fluorescence from PtPd NPs@TPE at 442 nm. On this basis, a ratiometric fluorescence strategy integrated with smartphone-based sensor was developed for PUT with acceptable results to combat food freshness fraud of soy products.
Collapse
|
115
|
Renart ML, Giudici AM, González-Ros JM, Poveda JA. Steady-state and time-resolved fluorescent methodologies to characterize the conformational landscape of the selectivity filter of K + channels. Methods 2024; 225:89-99. [PMID: 38508347 DOI: 10.1016/j.ymeth.2024.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 02/02/2024] [Accepted: 02/23/2024] [Indexed: 03/22/2024] Open
Abstract
A variety of equilibrium and non-equilibrium methods have been used in a multidisciplinary approach to study the conformational landscape associated with the binding of different cations to the pore of potassium channels. These binding processes, and the conformational changes resulting therefrom, modulate the functional properties of such integral membrane properties, revealing these permeant and blocking cations as true effectors of such integral membrane proteins. KcsA, a prototypic K+ channel from Streptomyces lividans, has been extensively characterized in this regard. Here, we revise several fluorescence-based approaches to monitor cation binding under different experimental conditions in diluted samples, analyzing the advantages and disadvantages of each approach. These studies have contributed to explain the selectivity, conduction, and inactivation properties of K+ channels at the molecular level, together with the allosteric communication between the two gates that control the ion channel flux, and how they are modulated by lipids.
Collapse
|
116
|
Wang F, Xiao M, Qi J, Zhu L. Paper-based fluorescence sensor array with functionalized carbon quantum dots for bacterial discrimination using a machine learning algorithm. Anal Bioanal Chem 2024; 416:3139-3148. [PMID: 38632131 PMCID: PMC11068836 DOI: 10.1007/s00216-024-05262-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 03/05/2024] [Accepted: 03/21/2024] [Indexed: 04/19/2024]
Abstract
The rapid discrimination of bacteria is currently an emerging trend in the fields of food safety, medical detection, and environmental observation. Traditional methods often require lengthy culturing processes, specialized analytical equipment, and bacterial recognition receptors. In response to this need, we have developed a paper-based fluorescence sensor array platform for identifying different bacteria. The sensor array is based on three unique carbon quantum dots (CQDs) as sensing units, each modified with a different antibiotic (polymyxin B, ampicillin, and gentamicin). These antibiotic-modified CQDs can aggregate on the bacterial surface, triggering aggregation-induced fluorescence quenching. The sensor array exhibits varying fluorescent responses to different bacterial species. To achieve low-cost and portable detection, CQDs were formulated into fluorescent ink and used with an inkjet printer to manufacture paper-based sensor arrays. A smartphone was used to collect the responses generated by the bacteria and platform. Diverse machine learning algorithms were utilized to discriminate bacterial types. Our findings showcase the platform's remarkable capability to differentiate among five bacterial strains, within a detection range spanning from 1.0 × 103 CFU/mL to 1.0 × 107 CFU/mL. Its practicality is further validated through the accurate identification of blind bacterial samples. With its cost-effectiveness, ease of fabrication, and high degree of integration, this platform holds significant promise for on-site detection of diverse bacteria.
Collapse
|
117
|
Dua A, Saini P, Goyal S, Selvam P, Ashok Kumar SK, Thiruppathi G, Sundararaj P, Sharma HK, Kumar Ramasamy S. Chromene-chromene Schiff base as a fluorescent chemosensor for Th 4+ and its application in bioimaging of Caenorhabditis elegans. Methods 2024; 225:28-37. [PMID: 38485032 DOI: 10.1016/j.ymeth.2024.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/28/2024] [Accepted: 03/07/2024] [Indexed: 03/22/2024] Open
Abstract
The manuscript presents the synthesis of a new di-chromene Schiff base (COM-CH) by combining 7-(diethylamino)-2-oxo-2H-chromene-3-carbohydrazide and 4-oxo-4H-chromene-3-carbaldehyde, and its characterization using various analytical techniques. The probe COM-CH functional group contains a hard donor atom that selectively complexes with Th4+ ions. This report investigated COM-CH's sensing ability towards Th4+ chromogenic and fluorogenic methods in ACN: H2O (8:2, v/v) with Th4+ ions. The COM-CH-Th4+ complex was excited at 430 nm, resulting in a bright emission band at 475 nm with a 45 nm Stokes shift. The COM-CH probe demonstrated the highest performance at pH 4.0 to 8.0, with a sensitivity of 18.7 nM. The complex formation of COM-CH with Th4+ was investigated using NMR, FTIR spectrometry, and density functional theory calculations. The COM-CH and Th4+ are bound with 2:1 stoichiometry and an association constant of 1.92 × 108 M-2. The probe's performance enabled the analysis of monazite sand and water samples for Th4+ content. The probe successfully detected Th4+ content in Caenorhabditis elegans, marking the first Th4+ detection in animal models.
Collapse
|
118
|
Ramadan HS, Abdel Salam RA, Hadad GM, Belal F, Salim MM. First derivative synchronous spectrofluorimetric method for the simultaneous determination of tramadol and celecoxib in their dosage forms and human plasma. LUMINESCENCE 2024; 39:e4774. [PMID: 38757441 DOI: 10.1002/bio.4774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 02/20/2024] [Accepted: 05/03/2024] [Indexed: 05/18/2024]
Abstract
One of the most common features of many different clinical conditions is pain; hence, there is a crucial need for eliminating or reducing it to a tolerable level to retrieve physical, psychological and social functioning. A first derivative synchronous spectrofluorimetry technique is proposed for the simultaneous determination of celecoxib and tramadol HCl, a recent coformulation authorized for treating acute pain in adults. The method includes using synchronous spectrofluorimetry at ∆λ = 80 nm where tramadol HCl was determined using first derivative technique at λ = 230.2 nm, while celecoxib was determined at λ = 288.24 nm. The proposed method was successfully applied to their co-formulated dosage forms in addition to spiked human plasma and validated in agreement with the guidelines of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). The linear ranges were found to be 0.50-5.0 and 0.15-0.50, the limits of detection to be 0.088 and 0.011 and the limits of quantification to be 0.266 and 0.032 μg/ml for celecoxib and tramadol, respectively. Statistical analysis revealed no significant difference when compared with previously reported methods as evidenced by the values of the variance ratio F-test and Student t-test. The proposed method was successfully applied to commercial dosage forms and spiked human samples. Moreover, the greenness of the proposed method was investigated based on the analytical eco-scale approach, with the results showing an excellent green scale with a score of 95.
Collapse
|
119
|
Choi NE, Lee YK, Oh H, Hur J. Photo-induced leaching behaviors and biodegradability of dissolved organic matter from microplastics and terrestrial-sourced particles. CHEMOSPHERE 2024; 355:141826. [PMID: 38552805 DOI: 10.1016/j.chemosphere.2024.141826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 03/25/2024] [Accepted: 03/26/2024] [Indexed: 04/01/2024]
Abstract
Recent studies have increasingly focused on the occurrence of plastic leachate and its impacts on aquatic ecosystems. Nonetheless, the environmental fate of this leachate in the presence of abundant natural organic matter (NOM)-a typical scenario in environments contaminated with plastics-remains underexplored. This study investigates the photo-induced leaching behaviors of dissolved organic matter (DOM) from terrestrial-sourced particles (forest soil and leaf litter) and microplastics (MPs), specifically polystyrene (PS) and polyvinyl chloride (PVC), over a two-week period. We also examined the biodegradability and spectroscopic characteristics of the leached DOM from both sources. Our results reveal that DOM from microplastics (MP-DOM) demonstrates more persistent leaching behavior compared to terrestrial-derived DOM, even with lesser quantities per unit of organic carbon. UV irradiation was found to enhance DOM leaching across all particle types. However, the photo-induced leaching behaviors of fluorescent components varied with the particle type. The MP group exhibited a broader range and higher biodegradability (ranging from 19.7% to 61.6%) compared to the terrestrial-sourced particles (ranging from 3.7% to 16.5%). DOM leached under UV irradiation consistently showed higher biodegradability than that under dark conditions. Furthermore, several fluorescence characteristics of DOM, such as the protein/phenol-like component (%C2), terrestrial humic-like component (%C3), and humification index (HIX)-traditionally used to indicate the biodegradability of natural organic matter-were also effective in assessing MP-DOM (with correlation coefficients R2 = 0.6055 (p = 0.003), R2 = 0.5389 (p = 0.007), and R2 = 0.4640 (p = 0.015), respectively). This study provides new insights into the potential differences in environmental fate between MP-DOM and NOM in aquatic environments heavily contaminated with MPs.
Collapse
|
120
|
Song H, Dong C, Ren J. Simultaneously Monitoring Multiple Autophagic Processes and Assessing Autophagic Flux in Single Cells by In Situ Fluorescence Cross-Correlation Spectroscopy. Anal Chem 2024; 96:6802-6811. [PMID: 38647189 DOI: 10.1021/acs.analchem.4c00725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Autophagy is a widely conserved and multistep cellular catabolic process and maintains cellular homeostasis and normal cellular functions via the degradation of some harmful intracellular components. It was reported that high basal autophagic activity may be closely related to tumorigenesis. So far, the fluorescence imaging technique has been widely used to study autophagic processes, but this method is only suitable for distinguishing autophagosomes and autolysosomes. Simultaneously monitoring multiple autophagic processes remains a significant challenge due to the lack of an efficient detection method. Here, we demonstrated a new method for simultaneously monitoring multiple autophagic processes and assessing autophagic flux in single cells based on in situ fluorescence cross-correlation spectroscopy (FCCS). In this study, microtubule-associated protein 1A/1B-light chain 3B (LC3B) was fused with two tandem fluorescent proteins [mCherry red fluorescent protein (mCherry) and enhanced green fluorescent protein (EGFP)] to achieve the simultaneous labeling and distinguishing of multiple autophagic structures based on the differences in characteristic diffusion time (τD). Furthermore, we proposed a new parameter "delivery efficiency of autophagosome (DEAP)" to assess autophagic flux based on the cross correlation (CC) value. Our results demonstrate that FCCS can efficiently distinguish three autophagic structures, assess the induced autophagic flux, and discriminate different autophagy regulators. Compared with the commonly used fluorescence imaging technique, the resolution of FCCS remains unaffected by Brownian motion and fluorescent monomers in the cytoplasm and is well suitable to distinguishing differently colored autophagic structures and monitoring autophagy.
Collapse
|
121
|
Deo BS, Nayak S, Pal M, Panigrahi PK, Pradhan A. Wavelet scattering transform and entropy features in fluorescence spectral signal analysis for cervical cancer diagnosis. Biomed Phys Eng Express 2024; 10:045002. [PMID: 38636479 DOI: 10.1088/2057-1976/ad403a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 04/18/2024] [Indexed: 04/20/2024]
Abstract
Cervical cancer is a prevalent malignant tumor within the female reproductive system and is regarded as a prominent cause of female mortality on a global scale. Timely and precise detection of various phases of cervical cancer holds the potential to substantially enhance both the rate of successful treatment and the duration of patient survival. Fluorescence spectroscopy is a highly sensitive method for detecting the biochemical changes that arise during cancer progression. In our study, fluorescence spectral data is collected from a diverse group of 110 subjects. The potential of the scattering transform technique for the purpose of cancer detection is explored. The processed signal undergoes an initial decomposition into scattering coefficients using the wavelet scattering transform (WST). Subsequently, the scattering coefficients are subjected to computation for fuzzy entropy, dispersion entropy, phase entropy, and spectral entropy, for effectively characterizing the fluorescence spectral signals. These combined features generated through the proposed approach are then fed to 1D convolutional neural network (CNN) classifier to classify them into normal, pre-cancerous, and cancerous categories, thereby evaluating the effectiveness of the proposed methodology. We obtained mean classification accuracy of 97% using 5-fold cross-validation. This demonstrates the potential of combining WST and entropic features for analyzing fluorescence spectroscopy signals using 1D CNN classifier that enables early cancer detection in contrast to prevailing diagnostic methods.
Collapse
|
122
|
Li C, Liu BT, Wang YT, Zhang TJ, Zheng X, Chen L, Li S, Tian X, Zhang D, Wang Y. A hydrogel-based ratiometric fluorescent sensor relying on rhodamine B labelled AIE-featured hyperbranched poly(amido amine) for heparin detection. Anal Chim Acta 2024; 1300:342466. [PMID: 38521573 DOI: 10.1016/j.aca.2024.342466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/22/2024] [Accepted: 03/10/2024] [Indexed: 03/25/2024]
Abstract
The fluorescent flexible sensor for point-of-care quantification of clinical anticoagulant drug, Heparin (Hep), is still an urgent need of breakthrough. In this research, a hyperbranched poly(amido amine) (HPA) was decorated with tetraphenylethene (TPE) and Rhodamine B (RhB), constructing a ratiometric fluorescent sensor (TR-HPA) for Hep. When the sensor was exposed to Hep, the TPE units within the probe skeleton would aggregate, resulting in an increasing fluorescent emission at 483 nm. The 580 nm of fluorescence came from RhB enhance, simultaneously, due to the fluorescence resonance energy transfer. As a result, there are two good linear correlation between the fluorescence emission ratio (E483/E580) of TR-HPA and the Hep concentration over a range of 0-1.0 μM, with a low limit of detection of 3.0 nM. Furthermore, we incorporate the TR-HPA probe into a polyvinyl alcohol (PVA) hydrogel matrix to create a flexible fluorescent sensing system platform, denoted as TR-HPA/PVA. This approach offers a straightforward visual detection method by causing a fluorescence color change from pink to blue when trace amounts of Hep are present. The hydrogel-based fluorescent sensor streamlines the detection procedures for Hep in biomedical applications. It shows great potential in rapid and point-of-care human blood clotting condition monitoring, making it suitable for next-generation wearable medical devices.
Collapse
|
123
|
Liu J, Yu W, Dong C, Huang X, Ren J. Objective scanning-based fluorescence cross-correlation spectroscopy (Scan-FCCS) for studying the fusion dynamics of protein phase separation. Analyst 2024; 149:2719-2727. [PMID: 38525957 DOI: 10.1039/d4an00264d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
Protein phase separation plays a very important role in many biological processes and is closely related to the occurrence and development of some serious diseases. So far, the fluorescence imaging method and fluorescence correlation spectroscopy (FCS) have been frequently used to study the phase separation behavior of proteins. Due to the wide size distribution of protein condensates in phase separation from nano-scale to micro-scale in solution and living cells, it is difficult for the fluorescence imaging method and conventional FCS to fully reflect the real state of protein phase separation in the solution due to the low spatio-temporal resolution of the conventional fluorescence imaging method and the limited detection area of FCS. Here, we proposed a novel method for studying the protein phase separation process by objective scanning-based fluorescence cross-correlation spectroscopy (Scan-FCCS). In this study, CRDBP proteins were used as a model and respectively fused with fluorescent proteins (EGFP and mCherry). We first compared conventional FCS and Scan-FCS methods for characterizing the CRDBP protein phase separation behaviors and found that the reproducibility of Scan-FCS is significantly improved by the scanning mode. We studied the self-fusion process of mCherry-CRDBP and EGFP-CRDBP and observed that the phase change concentration of CRDBP was 25 nM and the fusion of mCherry-CRDBP and EGFP-CRDBP at 500 nM was completed within 70 min. We studied the effects of salt concentration and molecular crowding agents on the phase separation of CRDBP and found that salt can prevent the self-fusion of CRDBP and molecular crowding agents can improve the self-fusion of CRDBP. Furthermore, we found the recruitment behavior of CRDBP to β-catenin proteins and studied their recruitment dynamics. Compared to conventional FCS, Scan-FCCS can significantly improve the reproducibility of measurements due to the dramatic increase of detection zone, and more importantly, this method can provide information about self-fusion and recruitment dynamics in protein phase separation.
Collapse
|
124
|
Lewkowicz A, Walczewska-Szewc K, Czarnomska M, Gruszczyńska E, Pierpaoli M, Bogdanowicz R, Gryczyński Z. Molecular Design Using Selected Concentration Effects in Optically Activated Fluorescent Matrices. Int J Mol Sci 2024; 25:4804. [PMID: 38732024 PMCID: PMC11084466 DOI: 10.3390/ijms25094804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/19/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024] Open
Abstract
Molecular physics plays a pivotal role in various fields, including medicine, pharmaceuticals, and broader industrial applications. This study aims to enhance the methods for producing specific optically active materials with distinct spectroscopic properties at the molecular level, which are crucial for these sectors, while prioritizing human safety in both production and application. Forensic science, a significant socio-economic field, often employs hazardous substances in analyzing friction ridges on porous surfaces, posing safety concerns. In response, we formulated novel, non-toxic procedures for examining paper evidence, particularly thermal papers. Our laboratory model utilizes a polyvinyl alcohol polymer as a rigid matrix to emulate the thermal paper's environment, enabling precise control over the spectroscopic characteristics of 1,8-diazafluoro-9-one (DFO). We identified and analyzed the cyclodimer 1,8-diazafluoren-9-one (DAK DFO), which is a non-toxic and biocompatible alternative for revealing forensic marks. The reagents used to preserve fingerprints were optimized for their effectiveness and stability. Using stationary absorption and emission spectroscopy, along with time-resolved emission studies, we verified the spectroscopic attributes of the new structures under deliberate aggregation conditions. Raman spectroscopy and quantum mechanical computations substantiated the cyclodimer's configuration. The investigation provides robust scientific endorsement for the novel compound and its structural diversity, influenced by the solvatochromic sensitivity of the DFO precursor. Our approach to monitoring aggregation processes signifies a substantial shift in synthetic research paradigms, leveraging simple chemistry to yield an innovative contribution to forensic science methodologies.
Collapse
|
125
|
Trujillo J, Khan AS, Adhikari DP, Stoneman MR, Chacko JV, Eliceiri KW, Raicu V. Implementation of FRET Spectrometry Using Temporally Resolved Fluorescence: A Feasibility Study. Int J Mol Sci 2024; 25:4706. [PMID: 38731924 PMCID: PMC11083457 DOI: 10.3390/ijms25094706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Revised: 04/21/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Förster resonance energy transfer (FRET) spectrometry is a method for determining the quaternary structure of protein oligomers from distributions of FRET efficiencies that are drawn from pixels of fluorescence images of cells expressing the proteins of interest. FRET spectrometry protocols currently rely on obtaining spectrally resolved fluorescence data from intensity-based experiments. Another imaging method, fluorescence lifetime imaging microscopy (FLIM), is a widely used alternative to compute FRET efficiencies for each pixel in an image from the reduction of the fluorescence lifetime of the donors caused by FRET. In FLIM studies of oligomers with different proportions of donors and acceptors, the donor lifetimes may be obtained by fitting the temporally resolved fluorescence decay data with a predetermined number of exponential decay curves. However, this requires knowledge of the number and the relative arrangement of the fluorescent proteins in the sample, which is precisely the goal of FRET spectrometry, thus creating a conundrum that has prevented users of FLIM instruments from performing FRET spectrometry. Here, we describe an attempt to implement FRET spectrometry on temporally resolved fluorescence microscopes by using an integration-based method of computing the FRET efficiency from fluorescence decay curves. This method, which we dubbed time-integrated FRET (or tiFRET), was tested on oligomeric fluorescent protein constructs expressed in the cytoplasm of living cells. The present results show that tiFRET is a promising way of implementing FRET spectrometry and suggest potential instrument adjustments for increasing accuracy and resolution in this kind of study.
Collapse
|