126
|
Agricola R, Leyland KM, Bierma-Zeinstra SMA, Thomas GE, Emans PJ, Spector TD, Weinans H, Waarsing JH, Arden NK. Validation of statistical shape modelling to predict hip osteoarthritis in females: data from two prospective cohort studies (Cohort Hip and Cohort Knee and Chingford). Rheumatology (Oxford) 2015; 54:2033-41. [PMID: 26139655 DOI: 10.1093/rheumatology/kev232] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES To prospectively investigate whether hip shape variants at baseline are associated with the need for future total hip replacement (THR) in women and to validate the resulting associated shape variants of the Cohort Hip and Cohort Knee (CHECK) cohort and the Chingford cohort. METHODS Female participants from the CHECK cohort without radiographic OA (Kellgren-Lawrence score <2) at baseline were included (1100 hips); 22 hips had a THR within 5 years of follow-up. For the Chingford cohort, with only female participants, hips without radiographic OA at baseline were selected and a nested case-control design was used, with 19 THR cases within 19 years of follow-up and 95 controls matched 5 to 1 for age and BMI. Hip shape on baseline anteroposterior pelvic radiographs was assessed by statistical shape modelling (SSM) using the same model for both cohorts. RESULTS In the CHECK and Chingford cohorts, the respective mean age was 55.8 (s.d. 5.1) and 53.6 (s.d. 5.4) and the BMI was 26.14 (s.d. 4.3) and 25.7 (s.d. 3.3), respectively. Multiple shape variants of the hip were significantly (P < 0.05) associated with future THR in both the CHECK (modes 4, 11, 15, 17 and 22) and Chingford (modes 2 and 17) cohorts. Mode 17 [odds ratio (OR) 0.51 (95% CI 0.33, 0.80) in the CHECK cohort], representing a flattened head-neck junction and flat greater trochanter, could be confirmed in the Chingford cohort [OR 0.41 (95% CI 0.23, 0.82)]. Modes 4 and 15 of the CHECK cohort also showed non-significant trends in the Chingford cohort. CONCLUSION Several baseline shape variants are associated with the future need for THR within a cohort. Despite differences in participant characteristics, radiographic protocol and follow-up time, we could validate at least one shape variant, suggesting that SSM is reasonably transferable between cohorts.
Collapse
|
127
|
Arbabi V, Pouran B, Weinans H, Zadpoor AA. Transport of Neutral Solute Across Articular Cartilage: The Role of Zonal Diffusivities. J Biomech Eng 2015; 137:2210662. [DOI: 10.1115/1.4030070] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Indexed: 02/02/2023]
Abstract
Transport of solutes through diffusion is an important metabolic mechanism for the avascular cartilage tissue. Three types of interconnected physical phenomena, namely mechanical, electrical, and chemical, are all involved in the physics of transport in cartilage. In this study, we use a carefully designed experimental-computational setup to separate the effects of mechanical and chemical factors from those of electrical charges. Axial diffusion of a neutral solute (Iodixanol) into cartilage was monitored using calibrated microcomputed tomography (micro-CT) images for up to 48 hr. A biphasic-solute computational model was fitted to the experimental data to determine the diffusion coefficients of cartilage. Cartilage was modeled either using one single diffusion coefficient (single-zone model) or using three diffusion coefficients corresponding to superficial, middle, and deep cartilage zones (multizone model). It was observed that the single-zone model cannot capture the entire concentration-time curve and under-predicts the near-equilibrium concentration values, whereas the multizone model could very well match the experimental data. The diffusion coefficient of the superficial zone was found to be at least one order of magnitude larger than that of the middle zone. Since neutral solutes were used, glycosaminoglycan (GAG) content cannot be the primary reason behind such large differences between the diffusion coefficients of the different cartilage zones. It is therefore concluded that other features of the different cartilage zones such as water content and the organization (orientation) of collagen fibers may be enough to cause large differences in diffusion coefficients through the cartilage thickness.
Collapse
|
128
|
Agricola R, Weinans H. What is femoroacetabular impingement? Br J Sports Med 2015; 50:196-7. [DOI: 10.1136/bjsports-2015-094766] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/09/2015] [Indexed: 11/03/2022]
|
129
|
Agricola R, Weinans H. Femoroacetabular impingement: what is its link with osteoarthritis? Br J Sports Med 2015; 50:957-8. [DOI: 10.1136/bjsports-2015-094914] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/09/2015] [Indexed: 11/03/2022]
|
130
|
Wauthle R, Ahmadi SM, Amin Yavari S, Mulier M, Zadpoor AA, Weinans H, Van Humbeeck J, Kruth JP, Schrooten J. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 54:94-100. [PMID: 26046272 DOI: 10.1016/j.msec.2015.05.001] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 03/17/2015] [Accepted: 05/02/2015] [Indexed: 01/16/2023]
Abstract
Additive manufacturing techniques are getting more and more established as reliable methods for producing porous metal implants thanks to the almost full geometrical and mechanical control of the designed porous biomaterial. Today, Ti6Al4V ELI is still the most widely used material for porous implants, and none or little interest goes to pure titanium for use in orthopedic or load-bearing implants. Given the special mechanical behavior of cellular structures and the material properties inherent to the additive manufacturing of metals, the aim of this study is to investigate the properties of selective laser melted pure unalloyed titanium porous structures. Therefore, the static and dynamic compressive properties of pure titanium structures are determined and compared to previously reported results for identical structures made from Ti6Al4V ELI and tantalum. The results show that porous Ti6Al4V ELI still remains the strongest material for statically loaded applications, whereas pure titanium has a mechanical behavior similar to tantalum and is the material of choice for cyclically loaded porous implants. These findings are considered to be important for future implant developments since it announces a potential revival of the use of pure titanium for additively manufactured porous implants.
Collapse
|
131
|
van der Stok J, Lozano D, Chai YC, Amin Yavari S, Bastidas Coral AP, Verhaar JA, Gómez-Barrena E, Schrooten J, Jahr H, Zadpoor AA, Esbrit P, Weinans H. Osteostatin-Coated Porous Titanium Can Improve Early Bone Regeneration of Cortical Bone Defects in Rats. Tissue Eng Part A 2015; 21:1495-506. [DOI: 10.1089/ten.tea.2014.0476] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
132
|
Ahmadi SM, Yavari SA, Wauthle R, Pouran B, Schrooten J, Weinans H, Zadpoor AA. Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties. MATERIALS 2015; 8:1871-1896. [PMID: 28788037 PMCID: PMC5507048 DOI: 10.3390/ma8041871] [Citation(s) in RCA: 122] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2015] [Revised: 04/08/2015] [Accepted: 04/14/2015] [Indexed: 01/02/2023]
Abstract
It is known that the mechanical properties of bone-mimicking porous biomaterials are a function of the morphological properties of the porous structure, including the configuration and size of the repeating unit cell from which they are made. However, the literature on this topic is limited, primarily because of the challenge in fabricating porous biomaterials with arbitrarily complex morphological designs. In the present work, we studied the relationship between relative density (RD) of porous Ti6Al4V EFI alloy and five compressive properties of the material, namely elastic gradient or modulus (Es20–70), first maximum stress, plateau stress, yield stress, and energy absorption. Porous structures with different RD and six different unit cell configurations (cubic (C), diamond (D), truncated cube (TC), truncated cuboctahedron (TCO), rhombic dodecahedron (RD), and rhombicuboctahedron (RCO)) were fabricated using selective laser melting. Each of the compressive properties increased with increase in RD, the relationship being of a power law type. Clear trends were seen in the influence of unit cell configuration and porosity on each of the compressive properties. For example, in terms of Es20–70, the structures may be divided into two groups: those that are stiff (comprising those made using C, TC, TCO, and RCO unit cell) and those that are compliant (comprising those made using D and RD unit cell).
Collapse
|
133
|
Waarsing JH, Bierma-Zeinstra SMA, Weinans H. Distinct subtypes of knee osteoarthritis: data from the Osteoarthritis Initiative. Rheumatology (Oxford) 2015; 54:1650-8. [PMID: 25882850 DOI: 10.1093/rheumatology/kev100] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE OA is suspected to be a collection of distinct subtypes, each with different aetiology and clinical characteristics. We aimed to explore the existence of different subtypes of knee OA, using cluster analysis of the data of the OA Initiative. METHODS We used latent class cluster analysis (LCA) to cluster baseline data of 518 subjects of the OA Initiative progression cohort. Data included radiographic scores of OA features per compartment, regional quantitative MRI measures of cartilage quantity and denuded bone, and self-reported clinical scores on knee symptoms. To ensure that the clusters were found independently of OA severity, the LCA model was corrected with a measure of OA severity. The resulting clusters were compared with respect to the presence of risk factors and progression. RESULTS LCA resulted in four clusters containing 47%, 27%, 15% and 12% of the subjects. Clusters 1, 2 and 4 showed OA features at the medial compartment, while cluster 3 only showed lateral OA features. Clusters 3 and 4 showed severe increases in areas of denuded bone, whereas no denuded bone was present in cluster 1. Prevalence of OA progression over 24 months was highest in clusters 3 and 4 and lowest in cluster 1. The clusters also differed significantly in BMI, knee alignment and prevalence of reported trauma. CONCLUSION LCA confirmed the existence of distinct subtypes of knee OA with clear differences in structural degradation and symptoms. The fact that subtypes also differed in risk factors suggests that different causes lead to different types of knee OA.
Collapse
|
134
|
van der Stok J, Koolen MKE, de Maat MPM, Yavari SA, Alblas J, Patka P, Verhaar JAN, van Lieshout EMM, Zadpoor AA, Weinans H, Jahr H, Jahr H. Full regeneration of segmental bone defects using porous titanium implants loaded with BMP-2 containing fibrin gels. Eur Cell Mater 2015; 29:141-53; discussion 153-4. [PMID: 25738583 DOI: 10.22203/ecm.v029a11] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Regeneration of load-bearing segmental bone defects is a major challenge in trauma and orthopaedic surgery. The ideal bone graft substitute is a biomaterial that provides immediate mechanical stability, while stimulating bone regeneration to completely bridge defects over a short period. Therefore, selective laser melted porous titanium, designed and fine-tuned to tolerate full load-bearing, was filled with a physiologically concentrated fibrin gel loaded with bone morphogenetic protein-2 (BMP-2). This biomaterial was used to graft critical-sized segmental femoral bone defects in rats. As a control, porous titanium implants were either left empty or filled with a fibrin gels without BMP-2. We evaluated bone regeneration, bone quality and mechanical strength of grafted femora using in vivo and ex vivo µCT scanning, histology, and torsion testing. This biomaterial completely regenerated and bridged the critical-sized bone defects within eight weeks. After twelve weeks, femora were anatomically re-shaped and revealed open medullary cavities. More importantly, new bone was formed throughout the entire porous titanium implants and grafted femora regained more than their innate mechanical stability: torsional strength exceeded twice their original strength. In conclusion, combining porous titanium implants with a physiologically concentrated fibrin gels loaded with BMP-2 improved bone regeneration in load-bearing segmental defects. This material combination now awaits its evaluation in larger animal models to show its suitability for grafting load-bearing defects in trauma and orthopaedic surgery.
Collapse
|
135
|
Das R, Timur U, Edip S, Haak E, Wruck C, Weinans H, Jahr H. TGF-β2 is involved in the preservation of the chondrocyte phenotype under hypoxic conditions. Ann Anat 2015; 198:1-10. [DOI: 10.1016/j.aanat.2014.11.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 11/02/2014] [Accepted: 11/14/2014] [Indexed: 12/13/2022]
|
136
|
Amin Yavari S, Ahmadi S, Wauthle R, Pouran B, Schrooten J, Weinans H, Zadpoor A. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials. J Mech Behav Biomed Mater 2015; 43:91-100. [DOI: 10.1016/j.jmbbm.2014.12.015] [Citation(s) in RCA: 248] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 12/09/2014] [Accepted: 12/11/2014] [Indexed: 01/02/2023]
|
137
|
Amin Yavari S, Chai YC, Böttger AJ, Wauthle R, Schrooten J, Weinans H, Zadpoor AA. Effects of anodizing parameters and heat treatment on nanotopographical features, bioactivity, and cell culture response of additively manufactured porous titanium. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 51:132-8. [PMID: 25842117 DOI: 10.1016/j.msec.2015.02.050] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 01/14/2015] [Accepted: 02/24/2015] [Indexed: 01/09/2023]
Abstract
Anodizing could be used for bio-functionalization of the surfaces of titanium alloys. In this study, we use anodizing for creating nanotubes on the surface of porous titanium alloy bone substitutes manufactured using selective laser melting. Different sets of anodizing parameters (voltage: 10 or 20V anodizing time: 30min to 3h) are used for anodizing porous titanium structures that were later heat treated at 500°C. The nanotopographical features are examined using electron microscopy while the bioactivity of anodized surfaces is measured using immersion tests in the simulated body fluid (SBF). Moreover, the effects of anodizing and heat treatment on the performance of one representative anodized porous titanium structures are evaluated using in vitro cell culture assays using human periosteum-derived cells (hPDCs). It has been shown that while anodizing with different anodizing parameters results in very different nanotopographical features, i.e. nanotubes in the range of 20 to 55nm, anodized surfaces have limited apatite-forming ability regardless of the applied anodizing parameters. The results of in vitro cell culture show that both anodizing, and thus generation of regular nanotopographical feature, and heat treatment improve the cell culture response of porous titanium. In particular, cell proliferation measured using metabolic activity and DNA content was improved for anodized and heat treated as well as for anodized but not heat-treated specimens. Heat treatment additionally improved the cell attachment of porous titanium surfaces and upregulated expression of osteogenic markers. Anodized but not heat-treated specimens showed some limited signs of upregulated expression of osteogenic markers. In conclusion, while varying the anodizing parameters creates different nanotube structure, it does not improve apatite-forming ability of porous titanium. However, both anodizing and heat treatment at 500°C improve the cell culture response of porous titanium.
Collapse
|
138
|
de Jonge S, Rozenberg R, Vieyra B, Stam HJ, Aanstoot HJ, Weinans H, van Schie HTM, Praet SFE. Achilles tendons in people with type 2 diabetes show mildly compromised structure: an ultrasound tissue characterisation study. Br J Sports Med 2015; 49:995-9. [PMID: 25586910 DOI: 10.1136/bjsports-2014-093696] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/19/2014] [Indexed: 12/31/2022]
Abstract
BACKGROUND Musculotendinous overuse injuries are prevalent in people with type 2 diabetes. Non-enzymatic glycosylation of collagen resulting in tendon stiffening may play a role. In this case-control study we determined whether patients with diabetes had poorer ultrasonographic structure in their Achilles tendons compared to age-matched controls. METHODS People with type 1 diabetes or type 2 diabetes, and age-matched controls, had computerised ultrasound tissue characterisation of both Achilles tendons. In contiguous ultrasonographic images of the tendon, echopatterns were quantified and categorised into four echo-types. Tendon abnormality was quantified as sum of echo-types III+IV. Furthermore, skin autofluorescence (AF) of the forearm (AF-value) was gathered. RESULTS Twenty four type 2 diabetes patients, 24 controls, 24 type 1 diabetes patients and 20 controls were included. AF-value was higher in type 1 diabetes (1.55±0.17) than in their controls (1.39±0.18, p<0.001) and in type 2 diabetes (2.28±0.38) compared to their controls (1.84±0.32, p<0.001) Achilles tendons of type 2 diabetes patients contained more echo-types III+IV (14.1±7.9%) than matched controls (8.0±5.4%, p<0.001). There was a trend towards a difference in echo-types III+IV between type 1 diabetes patients (9.5±5.3%) and their controls (6.5±3.7%, p=0.055). In a stepwise linear regression analysis, body mass index (BMI) was moderately associated with tendon abnormality in patients with diabetes and controls (β=0.393, p<0.001). CONCLUSIONS Type 2, and possibly type 1, diabetes patients showed poorer ultrasonographic Achilles tendon structure that may be a risk factor for tendinopathy. Although markers for accumulation of advanced glycation end products were elevated in both diabetes populations, only BMI was associated with these abnormalities. TRIAL REGISTRATION NUMBER NTR2209.
Collapse
|
139
|
Poldervaart MT, van der Stok J, de Haas MFP, 't Hart MC, Öner FC, Dhert WJ, Weinans H, Alblas J. Growth factor-induced osteogenesis in a novel radiolucent bone chamber. Eur Cell Mater 2015; 29:35-41; discussion 41. [PMID: 25552427 DOI: 10.22203/ecm.v029a03] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Treatment of large bone defects is currently performed using mainly autograft or allograft bone. There are important drawbacks to bone grafting, such as limited availability, donor site morbidity in the case of autograft and inferior performance of allografts. Therefore, there is a great need for a suitable bone graft substitute. In order to evaluate efficiently newly developed biomaterials and factors intended for orthopaedic surgery, the bone chamber is a very suitable model. To allow longitudinal investigation of bone growth with μCT, a new bone chamber made of radiolucent polyether ether ketone (PEEK) was developed and studied for its feasibility. Therefore, PEEK bone chambers were placed on rat tibiae, and filled with vehicle (Matrigel without growth factors, negative controls), with bone morphogenetic protein 2 (BMP-2, positive controls), or a mix of growth factors combining BMP-2, vascular endothelial growth factor and the chemokine stromal cell-derived factor 1α, all laden on gelatin microspheres for controlled release (combined growth factors). Growth factor presence led to a significant increase in bone formation after 8 weeks, which subsided after 12 weeks, underlining the importance of longitudinal analysis. We conclude that the PEEK-bone chamber is a suitable translational animal model to assess orthotopic bone formation in a longitudinal manner.
Collapse
|
140
|
Agricola R, Waarsing JH, Thomas GE, Carr AJ, Reijman M, Bierma-Zeinstra SMA, Glyn-Jones S, Weinans H, Arden NK. Response to letter to the editor: "Cam impingement: defining the presence of a cam deformity by the alpha angle data from the CHECK cohort an Chingford cohort". Osteoarthritis Cartilage 2014; 22:2095-6. [PMID: 25300576 DOI: 10.1016/j.joca.2014.09.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 09/30/2014] [Indexed: 02/02/2023]
|
141
|
Roels P, Agricola R, Oei EH, Weinans H, Campoli G, Zadpoor AA. Mechanical factors explain development of cam-type deformity. Osteoarthritis Cartilage 2014; 22:2074-82. [PMID: 25241242 DOI: 10.1016/j.joca.2014.09.011] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 09/04/2014] [Accepted: 09/06/2014] [Indexed: 02/02/2023]
Abstract
OBJECTIVE A cam-type deformity drastically increases the risk of hip osteoarthritis (OA). Since this type of skeletal anomaly is more prevalent among young active adults, it is hypothesized that the loading conditions experienced during certain types of vigorous physical activities stimulates formation of cam-type deformity. We further hypothesize that the growth plate shape modulates the influence of mechanical factors on the development of cam-type deformity. DESIGN We used finite element (FE) models of the proximal femur with an open growth plate to study whether mechanical factors could explain the development of cam-type deformity in adolescents. Four different loading conditions (representing different types of physical activities) and three different levels of growth plate extension towards the femoral neck were considered. Mechanical stimuli at the tissue level were calculated by means of the osteogenic index (OI) for all loading conditions and growth plate shape variations. RESULTS Loading conditions and growth plate shape influence the distribution of OI in hips with an open growth plate, thereby driving the development of cam-type deformity. In particular, specific types of loads experienced during physical activities and a larger growth plate extension towards the femoral neck increase the chance of cam-type deformity. CONCLUSIONS Specific loading patterns seem to stimulate the development of cam-type deformity by modifying the distribution of the mechanical stimulus. This is in line with recent clinical studies and reveals mechanobiological mechanisms that trigger the development of cam-type deformity. Avoiding these loading patterns during skeletal growth might be a potential preventative strategy for future hip OA.
Collapse
|
142
|
Campoli G, Baka N, Kaptein BL, Valstar ER, Zachow S, Weinans H, Zadpoor AA. Relationship between the shape and density distribution of the femur and its natural frequencies of vibration. J Biomech 2014; 47:3334-43. [PMID: 25171786 DOI: 10.1016/j.jbiomech.2014.08.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 08/04/2014] [Accepted: 08/08/2014] [Indexed: 11/17/2022]
Abstract
It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies.
Collapse
|
143
|
Siebelt M, Agricola R, Weinans H, Kim YJ. The role of imaging in early hip OA. Osteoarthritis Cartilage 2014; 22:1470-80. [PMID: 25278058 DOI: 10.1016/j.joca.2014.04.030] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 04/17/2014] [Accepted: 04/29/2014] [Indexed: 02/02/2023]
Abstract
Hip osteoarthritis (OA) is characterized by cartilage degradation, subchondral bone sclerosis and osteophyte formation. Nowadays, OA is thought to develop via different etiologies that all lead to a similar form of end stage joint degradation. One of these subtypes is related to an abnormal shaped hip joint, like acetabular dysplasia and a cam deformity. These bony abnormalities are highly predictive for development of hip OA, but they are likely to already be present from childhood. This suggests that these deformations induce OA changes in the hip, well before extensive hip degradation becomes present three to four decades later. Accurate detection and successful characterization of these early OA events might lead to better treatment options for hip OA besides nowadays available invasive joint replacement surgery. However, current diagnostic imaging techniques like radiographs or plain magnetic resonance imaging (MRI), are not sensitive enough to detect these subtle early OA changes. Nor are they able to disentangle intertwined and overlapping cascades from different OA subtypes, and neither can they predict OA progression. New and more sensitive imaging techniques might enable us to detect first OA changes on a cellular level, providing us with new opportunities for early intervention. In this respect, shape analysis using radiography, MRI, computed tomography (CT), single photon emission computed tomography (SPECT)/CT, and positron emission tomography (PET) might prove promising techniques and be more suited to detect early pathological changes in the hip joint. A broad application of these techniques might give us more understanding what can be considered physiological adaptation of the hip, or when early OA really starts. With a more clear definition of early OA, more homogenous patient populations can be selected and help with the development of new disease modifying OA interventions.
Collapse
|
144
|
Grassi L, Väänänen SP, Amin Yavari S, Jurvelin JS, Weinans H, Ristinmaa M, Zadpoor AA, Isaksson H. Full-Field Strain Measurement During Mechanical Testing of the Human Femur at Physiologically Relevant Strain Rates. J Biomech Eng 2014; 136:1901145. [DOI: 10.1115/1.4028415] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 08/27/2014] [Indexed: 11/08/2022]
Abstract
Understanding the mechanical properties of human femora is of great importance for the development of a reliable fracture criterion aimed at assessing fracture risk. Earlier ex vivo studies have been conducted by measuring strains on a limited set of locations using strain gauges (SGs). Digital image correlation (DIC) could instead be used to reconstruct the full-field strain pattern over the surface of the femur. The objective of this study was to measure the full-field strain response of cadaver femora tested at a physiological strain rate up to fracture in a configuration resembling single stance. The three cadaver femora were cleaned from soft tissues, and a white background paint was applied with a random black speckle pattern over the anterior surface. The mechanical tests were conducted up to fracture at a constant displacement rate of 15 mm/s, and two cameras recorded the event at 3000 frames per second. DIC was performed to retrieve the full-field displacement map, from which strains were derived. A low-pass filter was applied over the measured displacements before the crack opened in order to reduce the noise level. The noise levels were assessed using a dedicated control plate. Conversely, no filtering was applied at the frames close to fracture to get the maximum resolution. The specimens showed a linear behavior of the principal strains with respect to the applied force up to fracture. The strain rate was comparable to the values available in literature from in vivo measurements during daily activities. The cracks opened and fully propagated in less than 1 ms, and small regions with high values of the major principal strains could be spotted just a few frames before the crack opened. This corroborates the hypothesis of a strain-driven fracture mechanism in human bone. The data represent a comprehensive collection of full-field strains, both at physiological load levels and up to fracture. About 10,000 points were tracked on each bone, providing superior spatial resolution compared to ∼15 measurements typically collected using SGs. These experimental data collection can be further used for validation of numerical models, and for experimental verification of bone constitutive laws and fracture criteria.
Collapse
|
145
|
Sarkalkan N, Waarsing J, Bos P, Weinans H, Zadpoor A. Statistical shape and appearance models for fast and automated estimation of proximal femur fracture load using 2D finite element models. J Biomech 2014; 47:3107-14. [DOI: 10.1016/j.jbiomech.2014.06.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Revised: 04/30/2014] [Accepted: 06/18/2014] [Indexed: 11/30/2022]
|
146
|
Petit A, Sandker M, Müller B, Meyboom R, van Midwoud P, Bruin P, Redout EM, Versluijs-Helder M, van der Lest CH, Buwalda SJ, de Leede LG, Vermonden T, Kok RJ, Weinans H, Hennink WE. Release behavior and intra-articular biocompatibility of celecoxib-loaded acetyl-capped PCLA-PEG-PCLA thermogels. Biomaterials 2014; 35:7919-28. [DOI: 10.1016/j.biomaterials.2014.05.064] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Accepted: 05/21/2014] [Indexed: 01/26/2023]
|
147
|
van Buul GM, Siebelt M, Leijs MJC, Bos PK, Waarsing JH, Kops N, Weinans H, Verhaar JAN, Bernsen MR, van Osch GJVM. Mesenchymal stem cells reduce pain but not degenerative changes in a mono-iodoacetate rat model of osteoarthritis. J Orthop Res 2014; 32:1167-74. [PMID: 24839120 DOI: 10.1002/jor.22650] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2014] [Accepted: 04/24/2014] [Indexed: 02/04/2023]
Abstract
We studied the effects of intra-articularly injected bone marrow derived mesenchymal stem cells (MSCs), as well as freshly isolated bone marrow mononuclear cells (BMMNCs), on pain, cartilage damage, bone changes and inflammation in an in-vivo rat osteoarthritis (OA) model. OA was induced unilaterally by injection of mono-iodoacetate (MIA) and allowed to develop for 3 weeks. Then, animals were treated by intra-articular injection with MSCs, BMMNCs, or saline as a control. Four weeks later, pain was assessed with an incapitance tester, subchondral bone alterations were measured with µCT and cartilage quality and joint inflammation were assessed by histological analysis. Animals treated with MSCs distributed significantly more weight to the affected limb after treatment, which was not observed in the other groups. No statistically significant differences between treatment groups regarding cartilage damage, subchondral bone alterations and synovial inflammation were observed. Additional cell tracking experiments indicated adequate intra-articular cell injection and cell survival up to 2 weeks. In our OA model, injected MSCs were able to reduce MIA induced pain, as measured by an increased weight distribution to the affected limb. No statistically significant effects of the cellular therapies on structural damage and synovial inflammation were found.
Collapse
|
148
|
Siebelt M, Waarsing JH, Groen HC, Müller C, Koelewijn SJ, de Blois E, Verhaar JAN, de Jong M, Weinans H. Inhibited osteoclastic bone resorption through alendronate treatment in rats reduces severe osteoarthritis progression. Bone 2014; 66:163-70. [PMID: 24933343 DOI: 10.1016/j.bone.2014.06.009] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2014] [Revised: 06/05/2014] [Accepted: 06/06/2014] [Indexed: 11/30/2022]
Abstract
Osteoarthritis (OA) is a non-rheumatoid joint disease characterized by progressive degeneration of extra-cellular cartilage matrix (ECM), enhanced subchondral bone remodeling, osteophyte formation and synovial thickening. Alendronate (ALN) is a potent inhibitor of osteoclastic bone resorption and results in reduced bone remodeling. This study investigated the effects of pre-emptive use of ALN on OA related osteoclastic subchondral bone resorption in an in vivo rat model for severe OA. Using multi-modality imaging we measured effects of ALN treatment within cartilage and synovium. Severe osteoarthritis was induced in left rat knees using papain injections in combination with a moderate running protocol. Twenty rats were treated with subcutaneous ALN injections and compared to twenty untreated controls. Animals were longitudinally monitored for 12weeks with in vivo μCT to measure subchondral bone changes and SPECT/CT to determine synovial macrophage activation using a folate-based radiotracer. Articular cartilage was analyzed at 6 and 12weeks with ex vivo contrast enhanced μCT and histology to measure sulfated-glycosaminoglycan (sGAG) content and cartilage thickness. ALN treatment successfully inhibited subchondral bone remodeling. As a result we found less subchondral plate porosity and reduced osteophytosis. ALN treatment did not reduce subchondral sclerosis. However, after the OA induction phase, ALN treatment protected cartilage ECM from degradation and reduced synovial macrophage activation. Surprisingly, ALN treatment also improved sGAG content of tibia cartilage in healthy joints. Our data was consistent with the hypothesis that osteoclastic bone resorption might play an important role in OA and may be a driving force for progression of the disease. However, our study suggest that this effect might not solely be effects on osteoclastic activity, since ALN treatment also influenced macrophage functioning. Additionally, ALN treatment and physical activity exercised a positive effect in healthy control joints, which increased cartilage sGAG content. More research on this topic might lead to novel insights as to improve cartilage quality.
Collapse
|
149
|
van der Jagt OP, van der Linden JC, Waarsing JH, Verhaar JAN, Weinans H. Electromagnetic fields do not affect bone micro-architecture in osteoporotic rats. Bone Joint Res 2014; 3:230-5. [PMID: 25015993 PMCID: PMC4112789 DOI: 10.1302/2046-3758.37.2000221] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Objectives Electromagnetic fields (EMF) are widely used in musculoskeletal
disorders. There are indications that EMF might also be effective
in the treatment of osteoporosis. To justify clinical follow-up
experiments, we examined the effects of EMF on bone micro-architectural
changes in osteoporotic and healthy rats. Moreover, we tested the
effects of EMF on fracture healing. Methods EMF (20 Gauss) was examined in rats (aged 20 weeks), which underwent
an ovariectomy (OVX; n = 8) or sham-ovariectomy (sham-OVX; n = 8).
As a putative positive control, all rats received bilateral fibular
osteotomies to examine the effects on fracture healing. Treatment
was applied to one proximal lower leg (three hours a day, five days
a week); the lower leg was not treated and served as a control.
Bone architectural changes of the proximal tibia and bone formation
around the osteotomy were evaluated using in vivo microCT
scans at start of treatment and after three and six weeks. Results In both OVX and sham-OVX groups, EMF did not result in cancellous
or cortical bone changes during follow-up. Moreover, EMF did not
affect the amount of mineralised callus volume around the fibular
osteotomy. Conclusions In this study we were unable to reproduce the strong beneficial
findings reported by others. This might indicate that EMF treatment
is very sensitive to the specific set-up, which would be a serious
hindrance for clinical use. No evidence was found that EMF treatment
can influence bone mass for the benefit of osteoporotic patients. Cite this article: Bone Joint Res 2014;3:230–5.
Collapse
|
150
|
van der Linden JC, Waarsing JH, Weinans H. The use of micro-CT to study bone architecture dynamics noninvasively. DRUG DISCOVERY TODAY. TECHNOLOGIES 2014; 3:213-9. [PMID: 24980410 DOI: 10.1016/j.ddtec.2006.06.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
High-resolution micro-CT has become a standard tool in the evaluation of bone architecture. It has recently progressed from an invasive tool for bone specimens into an in vivo tool for small animals. The combination of novel sophisticated evaluation methods, such as registration (matching) of sequential scans and computer simulation models will further evolve in vivo micro-CT into an optimal tool for small animal phenotyping and contemporary approaches for drug discovery relating to the skeleton.:
Collapse
|