126
|
The management of upper airway obstruction in Pierre Robin Sequence. Paediatr Respir Rev 2023; 45:11-15. [PMID: 35987882 DOI: 10.1016/j.prrv.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 07/05/2022] [Indexed: 11/24/2022]
Abstract
Pierre Robin Sequence (PRS) is defined by a constellation of characteristics including micrognathia, glossoptosis and airway obstruction. PRS can occur in isolation or can be associated with syndromes and another anomalies. Airway obstruction and feeding difficulties are the major presenting issues, and the severity of the condition ranges from mild, with minimal to no symptoms, to severe, with overt obstruction resulting in apnoeas, severe respiratory distress and cyanosis. The presence of airway obstruction can result in obstructive sleep apnoea and abnormalities in gas exchange, as well as exacerbation of already present feeding difficulties and failure to thrive, secondary to mismatch of caloric intake to energy usage associated with increased effort of breathing. Management of airway obstruction for infants with PRS varies between centres. This paper explores the surgical and non-surgical management options available, their effectiveness and pitfalls in children with PRS. Despite the pros and cons of each management option, it is evident that resource availability and multidisciplinary clinical support are key factors to successful management.
Collapse
|
127
|
Hillamaa A, Mustonen T, Bachour A. CPAP-related aerophagia - Video findings of polysomnography and esophageal pH/impedance meter. Sleep Med 2023; 103:12-13. [PMID: 36724566 DOI: 10.1016/j.sleep.2022.11.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 11/04/2022] [Indexed: 01/20/2023]
|
128
|
Svensson M, Ekström M, Sundh J, Ljunggren M, Grote L, Palm A. Adherence to CPAP therapy in Down syndrome: the population-based DISCOVERY study. J Clin Sleep Med 2023; 19:453-458. [PMID: 36458740 PMCID: PMC9978440 DOI: 10.5664/jcsm.10364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 10/20/2022] [Accepted: 10/20/2022] [Indexed: 12/04/2022]
Abstract
STUDY OBJECTIVES Persons with Down syndrome (DS) have an increased risk of obstructive sleep apnea (OSA) needing continuous positive airway pressure (CPAP), but data on the therapy and outcomes in this population are scarce. We aimed to compare patient characteristics and outcomes of CPAP treatment for patients with OSA with and without DS. METHODS This was a population-based, longitudinal study on patients initiating CPAP therapy between July 2010 and March 2018 in Sweden and a population-based sex- and age-matched control group (control:case ratio 5:1), with linked data from the Swedish National Patient Registry and the Prescribed Drug Registry (DISCOVERY study cohort). RESULTS Patients with DS (n = 64) had a higher apnea-hypopnea index (51.7 ± 30.3 vs 36.8 ± 29.1 events/h, P < .001), Epworth Sleepiness Scale score (13.7 ± 5.9 vs 11.0 ± 4.9, P = .001), rate of previous surgery of tonsils and/or adenoids (21.9% vs 8.2%, P = .001), and more thyroid replacement hormone therapy (45.3% vs 7.8%, P < .001), but lower use of cardiovascular drugs (7.8% vs 22.3%, P = .003) compared with controls. At follow-up after 1.3 ± 0.9 years, there were no differences in nocturnal CPAP usage time (5.6 ± 2.4 vs 5.5 ± 2.0 hours, P = .77), CPAP adherence ≥ 4 hours/night (62% vs 65%, P = .93), or improvement in Epworth Sleepiness Scale score (-5.4 ± 6.8 vs -5.0 ± 2.0, P = .84) between DS and non-DS patients. CONCLUSIONS OSA severity was substantially higher in patients with DS despite an increased rate of tonsil surgery. Treatment outcomes in terms of adherence and improved daytime sleepiness were comparable between groups, underlining the importance of both OSA diagnosis and treatment in patients with DS. CITATION Svensson M, Ekström M, Sundh J, Ljunggren M, Grote L, Palm A. Adherence to CPAP therapy in Down syndrome: the population-based DISCOVERY study. J Clin Sleep Med. 2023;19(3):453-458.
Collapse
|
129
|
Joshi SS, Sivapalan D, Leclerc MJ, Kapur N. Home continuous positive airway pressure therapy in infants: a single-center experience. J Clin Sleep Med 2023; 19:473-477. [PMID: 36458731 PMCID: PMC9978439 DOI: 10.5664/jcsm.10366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 10/24/2022] [Accepted: 10/24/2022] [Indexed: 12/04/2022]
Abstract
STUDY OBJECTIVES There are limited data on indications and outcomes of home continuous positive airway pressure (CPAP) therapy in the first year of life. We aimed to analyze the clinical, demographic, and polysomnographic characteristics of a cohort of children initiated on home CPAP for treatment of sleep-disordered breathing and as respiratory support in the first year of life. METHODS Children started on CPAP in the first year of life at the Queensland Children's Hospital were retrospectively evaluated for clinical and demographic parameters, underlying diagnoses, respiratory support, airway surgical intervention, and polysomnography results at baseline and on CPAP. RESULTS Twenty-nine infants (median age [interquartile range] at CPAP initiation, 182 days [126-265.5 days]) were included. The underlying etiology included Trisomy 21 (n = 6), craniofacial syndromes (n = 5), hypotonia (n = 8; 5 with noncraniofacial syndrome), airway malacia (n = 5), skeletal dysplasia (n = 2), nonsyndromic upper airway obstruction (n = 2), and chronic neonatal lung disease (n = 1). The median (interquartile range) obstructive apnea-hypopnea index was 14 events/h (6.2-31 events/h) at CPAP initiation, which improved on CPAP to 3.4 events/h (1.4-6.4 events/h). The median (interquartile range) transcutaneous CO2 max remained unchanged on CPAP (56.6 mm Hg [49-66.5 mm Hg] pre-CPAP vs 54.9 mm Hg [47-62 mm Hg] on CPAP). Fifteen children needed surgical airway intervention (11 pre-CPAP and 4 post-CPAP). CPAP therapy could be successfully stopped in 9 children, 2 children needed tracheostomy, and 1 child died during the follow-up period. CONCLUSIONS Home CPAP as respiratory support is an effective long-term therapy in infancy, and these patients can be weaned from CPAP therapy even if it was initiated early. Prospective studies with predefined criteria for CPAP initiation and cessation would help ascertain long-term outcomes in this poorly researched group. CITATION Joshi SS, Sivapalan D, Leclerc M-J, Kapur N. Home continuous positive airway pressure therapy in infants: a single-center experience. J Clin Sleep Med. 2023;19(3):473-477.
Collapse
|
130
|
Polysomnographic evaluation of obstructive sleep apnea treatment with fixed pressure CPAP determined by formula. Sleep Breath 2023; 27:145-152. [PMID: 35244842 PMCID: PMC8895082 DOI: 10.1007/s11325-022-02583-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 02/02/2022] [Accepted: 02/09/2022] [Indexed: 11/11/2022]
Abstract
PURPOSE The use of continuous positive airway pressure (CPAP) is one of the therapeutic modalities for obstructive sleep apnea (OSA). Manual titration polysomnography and the 90th or 95th percentiles of pressure titrated by automatic CPAP (APAP) are the current standard for determining fixed pressure. Pressures programmed at an arbitrary fixed value, or at preset values based on body mass index (BMI) or by predictive formulas, are presented as alternative forms. This study aimed to evaluate the residual apnea-hypopnea index (r-AHI) in polysomnography with CPAP therapy using pressure determined by formula and assess its feasibility to start treatment. METHODS Patients referred for CPAP therapy were followed up in three outpatient assessments and underwent polysomnography study with pressure CPAP obtained by formula. RESULTS The study sample consisted of 80 patients, 41 women; age 58.6 ± 11.3 years, BMI 34.1 ± 7.5 kg/m2 and cervical circumference 42.0 ± 4.2 cm. Most patients (74%) had severe OSA and Epworth sleepiness scale (ESS) of 12.0 ± 5.7 points. The calculated average pressure was 7.8 ± 2.1 cmH2O. Polysomnography studies showed an r-AHI of 6.1 ± 5.2 events/h and reduction of 84% from baseline AHI. The r-AHI in the REM-supine was 8.4 ± 9.9 events/h. At 30- and 120-day follow-up assessment, adherence to CPAP was 78% and 75% and the ESS score was 6.9 and 6.1 points, respectively. CONCLUSION Results suggest that a formula provides an effective initial pressure in the majority of patients (73%). This simplified approach appears to be a viable alternative, with reductions in waiting lists and time from diagnosis to initiation of therapy.
Collapse
|
131
|
Bengtsson C, Grote L, Ljunggren M, Ekström M, Palm A. Nasal polyposis is a risk factor for nonadherence to CPAP treatment in sleep apnea: the population-based DISCOVERY study. J Clin Sleep Med 2023; 19:573-579. [PMID: 36546358 PMCID: PMC9978419 DOI: 10.5664/jcsm.10390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 11/02/2022] [Accepted: 11/02/2022] [Indexed: 12/24/2022]
Abstract
STUDY OBJECTIVES The aim was to evaluate nasal polyposis as a risk factor for nonadherence to continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). METHODS This was a population-based, longitudinal analysis of patients starting CPAP treatment for OSA in the Swedish quality registry Swedevox between 2010 and 2018. Data were cross-linked with national registries. The impact of nasal polyposis on CPAP adherence was analyzed using uni- and multivariable logistic and linear regression models. Relevant confounders (age, sex, usage of nasal and oral steroids) were identified using a direct acyclic graph. RESULTS Of 20,521 patients with OSA on CPAP treatment (29.5% females), 331 (1.6%) had a diagnosis of nasal polyposis at baseline. At the 1-year follow-up, nasal polyposis was associated with an increased risk of CPAP usage < 4 hours/night (unadjusted odds ratio [OR] 1.21; 95% confidence interval [CI] 0.95-1.55); adjusted OR 1.38; 95% CI 1.08-1.77). In this group, unadjusted nocturnal mean CPAP usage was 15.4 minutes (95% CI -31.62 to 0.83) shorter and was an adjusted 24.1 minutes (95% CI -40.6 to -7.7) shorter compared with patients with OSA without nasal polyposis. CONCLUSIONS Nasal polyposis is associated with reduced CPAP usage per night. These results highlight the importance of diagnosing nasal polyposis in patients with OSA before the start of CPAP treatment. Treatment of the condition may improve adherence, efficacy, and patient outcomes. CITATION Bengtsson C, Grote L, Ljunggren M, Ekström M, Palm A. Nasal polyposis is a risk factor for nonadherence to CPAP treatment in sleep apnea: the population-based DISCOVERY study. J Clin Sleep Med. 2023;19(3):573-579.
Collapse
|
132
|
Ullah MI, Tamanna S, Bhagat R. High nocturnal periodic breathing reported by PAP adherence data predicts decompensation of heart failure. J Clin Sleep Med 2023; 19:431-441. [PMID: 36310394 PMCID: PMC9978441 DOI: 10.5664/jcsm.10346] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 03/03/2023]
Abstract
STUDY OBJECTIVES Obstructive sleep apnea (OSA) often coexists with heart failure (HF) and is commonly treated with positive airway pressure (PAP) therapy. Periodic breathing (PB) may be present in HF and is an indicator of poor prognosis, but there is no easy way to detect PB in an outpatient setting. However, it can be detected by analyzing PAP usage data. The study aimed to assess if high PB% detected by PAP machine could predict impending HF exacerbation and if better PAP adherence is associated with reduced hospitalization and mortality. METHODS We retrospectively reviewed medical records of 115 patients with OSA from the sleep clinic of our VA Medical Center. The cross-sectional data on demographics, labs, PAP adherence, PB% in the previous 30 days, echocardiogram in the previous 6 months, and hospitalizations and mortality in the subsequent 180 days were extracted. Based on left ventricular ejection fraction (LVEF), patients were classified into (1) HF with normal-midrange LVEF (LVEF ≥40%, n = 74) and (2) HF with reduced LVEF (LVEF < 40%, n = 41). Pairwise correlation and linear regressions were done to assess predictors of PB%. Binomial and logistic regressions assessed the relationship of PB% and PAP adherence with hospitalization from HF and all-cause mortality. RESULTS In the HF with reduced LVEF group, the mean PB% was 2.6 times higher (P < .001) and PAP adherence was 29% lower (P < .001). PB% positively correlated with brain natriuretic peptide level (r = .447, P < .01) and number of hospitalizations (r = .331, P < .01). Higher PB% negatively correlated with LVEF (r = -.423, P < .01) and estimated glomerular filtration rate (r = -.246, P < .01). Every 10% increase in PAP adherence decreased odds of hospitalization by 0.78 times (P < .001) and odds of death by 0.86 (P = .043). CONCLUSIONS High PB% detected by PAP machine data is a predictor of impending HF exacerbation and hospitalization. Improved PAP adherence and optimization of medical therapy may reduce hospitalization and all-cause mortality. CITATION Ullah MI, Tamanna S, Bhagat R. High nocturnal periodic breathing reported by PAP adherence data predicts decompensation of heart failure. J Clin Sleep Med. 2023;19(3):431-441.
Collapse
|
133
|
Adi O, Fong CP, Keong YY, Apoo FN, Roslan NL. Helmet CPAP in the emergency department: A narrative review. Am J Emerg Med 2023; 67:112-119. [PMID: 36870251 DOI: 10.1016/j.ajem.2023.02.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/13/2023] [Accepted: 02/21/2023] [Indexed: 02/27/2023] Open
Abstract
BACKGROUND The choice of correct interface for the right patient is crucial for the success of non-invasive ventilation (NIV) therapy. Helmet CPAP is a type of interface used to deliver NIV. Helmet CPAP improves oxygenation by keeping the airway open throughout the breathing cycle with positive end-expiratory pressure (PEEP). OBJECTIVE This narrative review describes the technical aspects and clinical indications of helmet continuous positive airway pressure (CPAP). In addition, we explore the advantages and challenges faced using this device at the Emergency Department (ED). DISCUSSION Helmet CPAP is tolerable than other NIV interfaces, provides a good seal and has good airway stability. During Covid-19 pandemic, there are evidences it reduced the risk of aerosolization. The potential clinical benefit of helmet CPAP is demonstrated in acute cardiogenic pulmonary oedema (ACPO), Covid-19 pneumonia, immunocompromised patient, acute chest trauma and palliative patient. Compare to conventional oxygen therapy, helmet CPAP had been shown to reduce intubation rate and decrease mortality. CONCLUSION Helmet CPAP is one of the potential NIV interface in patients with acute respiratory failure presenting to the emergency department. It is better tolerated for prolonged usage, reduced intubation rate, improved respiratory parameters, and offers protection against aerosolization in infectious diseases.
Collapse
|
134
|
Fiorella M, Armache M, Scott E, Rodin J, Boon M, Huntley C. Comparison of CPAP and Expansion Sphincter Pharyngoplasty using the Mean Disease Alleviation Concept. Laryngoscope 2023; 133:1513-1517. [PMID: 36815599 DOI: 10.1002/lary.30613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/19/2023] [Accepted: 01/24/2023] [Indexed: 02/24/2023]
Abstract
OBJECTIVE Continuous Positive Airway Pressure (CPAP) is the typical first treatment for Obstructive Sleep Apnea (OSA); however, patient adherence is often suboptimal. Expansion Sphincter Pharyngoplasty (ESP) is an alternative treatment option for patients with OSA who demonstrate signs of palatal and lateral pharyngeal collapse. The aim of this study is to compare therapeutic outcomes, using the mean disease alleviation concept, for patients who underwent ESP to patients undergoing CPAP therapy. DATA SOURCES Single-institution retrospective cohort study. METHODS All patients who underwent ESP from 2018 to 2021 or were prescribed CPAP from December to June 2021 at our institution were assessed for inclusion. ESP patients who had pre- and post-operative sleep studies available and CPAP patients who followed up at our institution's sleep clinic were included for analysis. Charts were reviewed for demographic information and sleep study results, and treatment outcomes were measured by calculating mean disease alleviation. RESULTS There were 77 patients in the ESP group and 107 patients in the CPAP group. AHI reduction was greater in the CPAP group (p = 0.016); however, mean disease alleviation was similar between groups (p = 0.076). One-way ANCOVA demonstrated similar MDA between groups when controlling for patient age, BMI, gender, and pre-operative AHI (F [1,177] = 2,931.6, p = 0.104). CONCLUSION CPAP therapy provided superior reduction in AHI compared to ESP; however, overall treatment efficacy as measured by mean disease alleviation was similar for both groups. LEVEL OF EVIDENCE 3 Laryngoscope, 2023.
Collapse
|
135
|
Samaranayake CB, Turnbull C, Neubauer S, Kylintireas I, Stradling J, Craig S, McCabe C. Right ventricular responses to CPAP therapy in obstructive sleep apnea: CMR analysis of the MOSAIC randomized trial. Pulm Circ 2023; 13:e12201. [PMID: 36814585 PMCID: PMC9939623 DOI: 10.1002/pul2.12201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/23/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023] Open
Abstract
Effects of continuous positive airway pressure (CPAP) on right ventricular (RV) function in patients with untreated mild-to-moderate obstructive sleep apnea (OSA) are unclear. In this exploratory analysis of cardiac magnetic resonance (CMR)-derived indices of RV function in patients with minimally symptomatic OSA from the MOSAIC randomized control trial we found no effect of CPAP on RV CMR parameters. In those with lower RV ejection fraction and higher RV end-diastolic volume (EDV) at baseline, CPAP treatment appeared to improve RV function with a significant reduction in both RV EDV and RV end-systolic volume although between-group effects were not observed. These data suggest potential merit in a larger randomized study of CPAP in patients with mild-to-moderate OSA and a greater breadth of RV dysfunction.
Collapse
|
136
|
Cancelliere S, Heung T, Fischbach S, Klaiman P, Bassett AS. Adult-onset obstructive sleep apnea and pediatric pharyngoplasty in 22q11.2 deletion syndrome. Sleep Med 2023; 104:49-55. [PMID: 36889031 DOI: 10.1016/j.sleep.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 01/27/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023]
Abstract
OBJECTIVE/BACKGROUND We aimed to evaluate adult-onset obstructive sleep apnea (OSA) and related risk factors, including history of pediatric palatal/pharyngeal surgery to remediate velopharyngeal dysfunction, in 22q11.2 deletion syndrome (22q11.2DS). PATIENTS/METHODS Using a retrospective cohort design and standard sleep study-based criteria, we determined presence of adult-onset OSA (age ≥16 years) and relevant variables through comprehensive chart review in a well-characterized cohort of 387 adults with typical 22q11.2 microdeletions (51.4% female, median age 32.3, interquartile range 25.0-42.5, years). We used multivariate logistic regression to identify independent risk factors for OSA. RESULTS Of the 73 adults with sleep study data, 39 (53.4%) met criteria for OSA at median age 33.6 (interquartile range 24.0-40.7) years, indicating a minimum OSA prevalence of 10.1% in this 22q11.2DS cohort. History of pediatric pharyngoplasty (odds ratio 2.56, 95% confidence interval 1.15-5.70) was a significant independent predictor of adult-onset OSA, while accounting for other significant independent predictors (asthma, higher body mass index, older age), and for male sex. An estimated 65.5% of those prescribed continuous positive airway pressure therapy were reported as adherent. CONCLUSIONS In addition to factors of known importance in the general population, delayed effects of pediatric pharyngoplasty may contribute to risk of adult-onset OSA in individuals with 22q11.2DS. The results support increased index of suspicion for OSA in adults with a 22q11.2 microdeletion. Future research with this and other homogeneous genetic models may help to improve outcomes and to better understand genetic and modifiable risk factors for OSA.
Collapse
|
137
|
Ishman SL, Maturo S, Schwartz S, McKenna M, Baldassari CM, Bergeron M, Chernobilsky B, Ehsan Z, Gagnon L, Liu YCC, Smith DF, Stanley J, Zalzal H, Dhepyasuwan N. Expert Consensus Statement: Management of Pediatric Persistent Obstructive Sleep Apnea After Adenotonsillectomy. Otolaryngol Head Neck Surg 2023; 168:115-130. [PMID: 36757810 PMCID: PMC10105630 DOI: 10.1002/ohn.159] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/03/2022] [Accepted: 08/13/2022] [Indexed: 01/27/2023]
Abstract
OBJECTIVE To develop an expert consensus statement regarding persistent pediatric obstructive sleep apnea (OSA) focused on quality improvement and clarification of controversies. Persistent OSA was defined as OSA after adenotonsillectomy or OSA after tonsillectomy when adenoids are not enlarged. METHODS An expert panel of clinicians, nominated by stakeholder organizations, used the published consensus statement methodology from the American Academy of Otolaryngology-Head and Neck Surgery to develop statements for a target population of children aged 2-18 years. A medical librarian systematically searched the literature used as a basis for the clinical statements. A modified Delphi method was used to distill expert opinion and compose statements that met a standardized definition of consensus. Duplicate statements were combined prior to the final Delphi survey. RESULTS After 3 iterative Delphi surveys, 34 statements met the criteria for consensus, while 18 statements did not. The clinical statements were grouped into 7 categories: general, patient assessment, management of patients with obesity, medical management, drug-induced sleep endoscopy, surgical management, and postoperative care. CONCLUSION The panel reached a consensus for 34 statements related to the assessment, management and postoperative care of children with persistent OSA. These statements can be used to establish care algorithms, improve clinical care, and identify areas that would benefit from future research.
Collapse
|
138
|
Shen C, Liu X, Liu T, Ou Y, Ouyang R. IL-33/ST2 mediating systemic inflammation and neuroinflammation through NF-kB participated in the neurocognitive impairment in obstructive sleep apnea. Int Immunopharmacol 2023; 115:109604. [PMID: 36580760 DOI: 10.1016/j.intimp.2022.109604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 12/09/2022] [Accepted: 12/13/2022] [Indexed: 12/28/2022]
Abstract
Increasing evidence has noted that neuroinflammation contributes to the pathological processes of cognitive impairment of obstructive sleep apnea (OSA) patients. Interleukin (IL) -33/suppression of tumorigenicity 2 (ST2) signaling pathway plays well-defined roles in the inflammatory progression. The study aims to elucidate whether IL-33/ST2 signaling pathway plays a role in the cognitive dysfunction in patients with OSA via regulating neuroinflammation. We found that compared with control subjects, patients with OSA showed significantly elevated IL-33, ST2 and p65 nuclear factor-kappa B (NF-κB) levels in peripheral blood mononuclear cells (PBMCs) and inflammatory cytokines IL-6, IL-8 in serum, which were positively correlated with disease severity. Meanwhile, OSA patients exhibited a decline in Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA) scores, suggesting mild cognitive impairment. Continuous positive airway pressure (CPAP) treatment for 12 weeks significantly decreased the expression of IL-33, ST2, p65NF-κB, IL-6 and IL-8, as well as improved cognitive function of OSA patients. Moreover, the IL-33/ST2 signaling was closely correlated with sleep respiratory parameters and cognitive dysfunction. To further explore the underlying mechanism of IL-33/ST2 signaling pathway, we stimulated human microglial clone 3 (HMC3) cells with lipopolysaccharide (LPS) to mimic neuroinflammatory response in vitro. The results showed that LPS treatment led to an increase in IL-33 and ST2 expression in a dose- dependent manner, along with an increased secretion of IL-6 and IL-8. Functional experiments showed that knockdown of IL-33 ameliorated LPS-induced neuroinflammation via suppressing NF-κB signaling. Overall, current findings suggest that IL-33/ST2 signaling participated in the cognitive impairment of OSA patients by promoting neuroinflammation via activating NF-κB signaling. These results may provide a novel therapeutic target for treating OSA- associated cognitive dysfunction.
Collapse
|
139
|
Lowery MM, Rundo JV, Walia HK, Shah V. Personalized multimodal management for severe obstructive sleep apnea in a patient intolerant of positive airway pressure with hypoglossal nerve stimulator and mandibular advancement device. J Clin Sleep Med 2023; 19:403-408. [PMID: 36117433 PMCID: PMC9892739 DOI: 10.5664/jcsm.10296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 09/13/2022] [Accepted: 09/14/2022] [Indexed: 02/04/2023]
Abstract
Treatment of moderate to severe obstructive sleep apnea poses clinical challenges in persons with intolerance or inadequate response to traditional treatment modalities, including positive airway pressure and mandibular advancement devices. Hypoglossal nerve stimulation is a new treatment option, but few management guidelines exist when it is intolerable or ineffective. Combining several treatment modalities has been an effective strategy for improving symptoms, tolerance, and efficacy. We describe a patient intolerant to positive airway pressure therapy who had continued sleepiness, morning headaches, and snoring with a mandibular advancement device. He underwent hypoglossal nerve stimulation implantation but was intolerant of the voltages required to adequately control his obstructive sleep apnea. Multimodal management with hypoglossal nerve stimulation, mandibular advancement device, and positional therapy was successfully implemented to improve sleepiness, nocturnal symptoms, and the apnea-hypopnea index. This case highlights the personalization and adaptability of combination therapy to suit patient needs while effectively controlling obstructive sleep apnea. CITATION Lowery MM, Rundo JV, Walia HK, Shah V. Personalized multimodal management for severe obstructive sleep apnea in a patient intolerant of positive airway pressure with hypoglossal nerve stimulator and mandibular advancement device. J Clin Sleep Med. 2023;19(2):403-408.
Collapse
|
140
|
Hirani R, Smiley A. A Scoping Review of Sleep Apnea: Where Do We Stand? Life (Basel) 2023; 13:life13020387. [PMID: 36836743 PMCID: PMC9961756 DOI: 10.3390/life13020387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/11/2023] [Accepted: 01/28/2023] [Indexed: 02/01/2023] Open
Abstract
Obstructive sleep apnea (OSA), a condition in which there is a recurrent collapse of the upper airway while sleeping, is a widespread disease affecting 5% to 10% people worldwide. Despite several advances in the treatment modalities for OSA, morbidity and mortality remain a concern. Common symptoms include loud snoring, gasping for air during sleep, morning headache, insomnia, hypersomnia, attention deficits, and irritability. Obese individuals, male gender, older age (65+), family history, smoking, and alcohol consumption are well recognized risk factors of OSA. This condition holds the ability to increase inflammatory cytokines, cause metabolic dysfunction, and increase the sympathetic output, all of which exacerbate OSA due to their effect on the cardiovascular system. In this review, we discuss its brief history, risk factors, complications, treatment modalities, and the role of clinicians in curbing its risk.
Collapse
|
141
|
Chen Y, Chen R, Lin Y, Lai J, Wang J, Zhu X, Liu Y, Zhang Z, Yang Y, Zhao D. Treatment of Obstructive Sleep Apnea and Diabetic Kidney Disease: Can CPAP Reduce Albuminuria Progression?. Am J Respir Crit Care Med 2023; 207:955-956. [PMID: 36693271 PMCID: PMC10111983 DOI: 10.1164/rccm.202211-2173le] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
|
142
|
Pataka A, Kotoulas SC, Gavrilis PR, Karkala A, Tzinas A, Stefanidou A. Adherence to CPAP Treatment: Can Mindfulness Play a Role? Life (Basel) 2023; 13:life13020296. [PMID: 36836653 PMCID: PMC9960813 DOI: 10.3390/life13020296] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 01/10/2023] [Accepted: 01/17/2023] [Indexed: 01/26/2023] Open
Abstract
Obstructive sleep apnea (OSA) is considered a chronic disease that requires long-term multidisciplinary management for effective treatment. Continuous Positive Airway Pressure (CPAP) is still considered the gold standard of therapy. However, CPAP effectiveness is limited due to poor patients' adherence, as almost 50% of patients discontinue treatment after a year. Several interventions have been used in order to increase CPAP adherence. Mindfulness-based therapies have been applied in other sleep disorders such as insomnia but little evidence exists for their application on OSA patients. This review aims to focus on the current data on whether mindfulness interventions may be used in order to increase CPAP adherence and improve the sleep quality of OSA patients. Even though controlled trials of mindfulness and CPAP compliance remain to be performed, this review supports the hypothesis that mindfulness may be used as an adjunct method in order to increase CPAP adherence in OSA patients.
Collapse
|
143
|
Buendía JA, Hernández-Sarmiento R, Rojas Medina JE. Cost-Utility of Continuous Positive Airway Pressure for Respiratory Distress in Preterm Infants in a Middle-Income Country. Value Health Reg Issues 2023; 35:1-7. [PMID: 36657278 DOI: 10.1016/j.vhri.2022.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 11/01/2022] [Accepted: 11/28/2022] [Indexed: 01/19/2023]
Abstract
OBJECTIVES Despite the increased popularity of continuous positive airway pressure (CPAP) for preterm infants with respiratory distress, there is still uncertainty about whether the additional costs of this device justify the clinical benefits provided. This study aims to evaluate the cost-utility of CPAP in spontaneously breathing preterm infants with respiratory distress. METHODS Using a decision tree model, we estimated the cost and quality-adjusted life-years (QALYs) associated with CPAP and supplemental oxygen alone by headbox or low-flow nasal cannula (SO). The model was analyzed probabilistically, and a value of information analysis was conducted to inform the value of conducting further research to reduce current uncertainties in the evidence base. Cost-effectiveness was evaluated at a willingness-to-pay value of US$5180. RESULTS The mean incremental cost of CPAP versus SO was US$600. The mean incremental benefit of CPAP versus SO was 0.04 QALY. The expected incremental cost per QALY was estimated at US$13 172. The mean incremental net monetary benefit was US$-324 with a 95% credible interval of US$-536 to US$-201. The overall expected value of perfect information per person affected by the decision was estimated to be US$2346. CONCLUSIONS Compared with SO, the use of CPAP in spontaneously breathing preterm infants with respiratory distress is not cost-effective in Colombia. Evidence should continue to be generated with real-life effectiveness data and economic evaluations in other countries to confirm our findings.
Collapse
|
144
|
Rossetto A, Midelet A, Baillieul S, Tamisier R, Borel JC, Prigent A, Bailly S, Pépin JL. Factors Associated With Residual Apnea-Hypopnea Index Variability During CPAP Treatment. Chest 2023; 163:1258-1265. [PMID: 36642368 DOI: 10.1016/j.chest.2022.12.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 12/12/2022] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND CPAP is the first-line therapy for OSA. A high or variable residual apnea-hypopnea index (rAHI) reflects treatment failure and potentially is triggered by exacerbation of cardiovascular comorbidities. Previous studies showed that high rAHI and large rAHI variability are associated with underlying comorbidities, OSA characteristics at diagnosis, and CPAP equipment, including mask type and settings. RESEARCH QUESTION What factors are associated with predefined groups with low to high rAHI variability? STUDY DESIGN AND METHODS This registry-based study included patients with a diagnosis of OSA who were receiving CPAP treatment with at least 90 days of CPAP remote monitoring. We applied the hidden Markov model to analyze the day-to-day trajectories of rAHI variability using telemonitoring data. An ordinal logistic regression analysis identified factors associated with a risk of having a higher and more variable rAHI with CPAP treatment. RESULTS The 1,126 included patients were middle-aged (median age, 66 years; interquartile range [IQR], 57-73 years), predominantly male (n = 791 [70.3%]), and obese (median BMI, 30.6 kg/m2 (IQR, 26.8-35.2 kg/m2). Three distinct groups of rAHI trajectories were identified using hidden Markov modeling: low rAHI variability (n = 393 [35%]), moderate rAHI variability group (n = 420 [37%]), and high rAHI variability group (n = 313 [28%]). In multivariate analysis, factors associated with high rAHI variability were age, OSA severity at diagnosis, heart failure, opioids and alcohol consumption, mental and behavioral disorders, transient ischemic attack and stroke, an oronasal mask, and level of leaks when using CPAP. INTERPRETATION Identifying phenotypic traits and factors associated with high rAHI variability will allow early intervention and the development of personalized follow-up pathways for CPAP treatment.
Collapse
|
145
|
Sacks M, Raidal S, Catanchin CSM, Hosgood G, Mosing M. Impact of sedation, body position change and continuous positive airway pressure on distribution of ventilation in healthy foals. Front Vet Sci 2023; 9:1075791. [PMID: 36713868 PMCID: PMC9880457 DOI: 10.3389/fvets.2022.1075791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/14/2022] [Indexed: 01/15/2023] Open
Abstract
Background This study aimed to compare the distribution of ventilation measured by electrical impedance tomography (EIT), in foals under varying clinical conditions of sedation, postural changes, and continuous positive airway pressure (CPAP). To support the interpretation of EIT variables, specific spirometry data and F-shunt calculation were also assessed. Materials and methods Six healthy Thoroughbred foals were recruited for this sequential experimental study. EIT and spirometry data was recorded: (1) before and after diazepam-sedation, (2) after moving from standing to right lateral recumbency, (3) in dorsal recumbency during no CPAP (CPAP0) and increasing levels of CPAP of 4, 7, and 10 cmH2O (CPAP4, 7, 10, respectively). Ventral to dorsal (COVVD) and right to left (COVRL) center of ventilation, silent spaces, tidal impedance variation, regional ventilation distribution variables and right to left lung ventilation ratio (R:L) were extracted. Minute ventilation was calculated from tidal volume (VT) and respiratory rate. F-Shunt was calculated from results of arterial blood gas analysis. Statistical analysis was performed using linear mixed effects models (significance determined at p < 0.05). Results (1) Respiratory rate was lower after sedation (p = 0.0004). (2) In right lateral recumbency (compared to standing), the COVVD (p = 0.0012), COVRL (p = 0.0057), left centro-dorsal (p = 0.0071) and dorsal (p < 0.0001) regional ventilation were higher, while the right ventral (p = 0.0016) and dorsal (p = 0.0145) regional ventilation, and R:L (p = 0.0017) were lower. (3) Data of two foals for CPAP10 was excluded from statistical analysis due to prolonged apnea. Stepwise increase of CPAP led to increases of COVVD (p = 0.0028) and VT (p = 0.0011). A reduction of respiratory rate was detected with increasing CPAP levels (p < 0.0001). Conclusions (1) In healthy foals, diazepam administration did not alter distribution of ventilation or minute ventilation, (2) lateral recumbency results in collapse of dependent areas of the lung, and (3) the use of CPAP in dorsal recumbency at increasing pressures improves ventilation in dependent regions, suggesting improvement of ventilation-perfusion mismatch.
Collapse
|
146
|
Outcome of Continuous Positive Airway Pressure Adherence Based on Nasal Endoscopy and the Measurement of Nasal Patency-A Prospective Study. LIFE (BASEL, SWITZERLAND) 2023; 13:life13010219. [PMID: 36676168 PMCID: PMC9867109 DOI: 10.3390/life13010219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/09/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023]
Abstract
The gold standard for treating obstructive sleep apnea in adults is continuous positive airway pressure (CPAP). However, it can be difficult to convince patients to adhere to this therapy. The aim of this study was to determine the relationship between nasal endoscopy findings/nose patency and CPAP adherence. Material and methods: A cohort of 450 consecutive patients suspected of having OSA were prospectively enrolled. For further analyses, 47 OSA patients undergoing CPAP treatment were selected (13 females and 34 males, average age, 65.3 years, BMI 34.1, apnea-hypopnea index. AHI 51.0). The patients were divided into two groups: patients with good CPAP adherence (n = 35) and patients who did not adhere to CPAP therapy (n = 12). The influence of nasal endoscopy and flow measurement on CPAP adherence was explored. Results: We found a statistical independence between adherence to CPAP and AHI (p = 0.124), T90 (p = 0.502), endoscopic findings (p = 0.588) and nasal patency measured by a flowmeter (p = 0.498). Conclusions: In our studied sample, endoscopic findings and nasal patency measured by a flowmeter were not predictors of CPAP non-adherence in the first year of the treatment. Our data show that while an endoscopic finding in the nasal cavity could indicate that a patient has a severe obstruction, compliance with CPAP therapy is not reduced in these patients and neither is it reduced with a decrease in nasal flow, according to our observation.
Collapse
|
147
|
Rathi V, Ish P. PAP Therapy Compliance in COVID-19: Multifactorial Etiologies to Consider. SLEEP AND VIGILANCE 2023; 7:1-2. [PMID: 36618852 PMCID: PMC9809506 DOI: 10.1007/s41782-022-00224-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/13/2022] [Accepted: 12/28/2022] [Indexed: 01/05/2023]
|
148
|
Hysinger EB, Ahlfeld SK. Respiratory support strategies in the prevention and treatment of bronchopulmonary dysplasia. Front Pediatr 2023; 11:1087857. [PMID: 36937965 PMCID: PMC10018229 DOI: 10.3389/fped.2023.1087857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 02/02/2023] [Indexed: 03/06/2023] Open
Abstract
Neonates who are born preterm frequently have inadequate lung development to support independent breathing and will need respiratory support. The underdeveloped lung is also particularly susceptible to lung injury, especially during the first weeks of life. Consequently, respiratory support strategies in the early stages of premature lung disease focus on minimizing alveolar damage. As infants grow and lung disease progresses, it becomes necessary to shift respiratory support to a strategy targeting the often severe pulmonary heterogeneity and obstructive respiratory physiology. With appropriate management, time, and growth, even those children with the most extreme prematurity and severe lung disease can be expected to wean from respiratory support.
Collapse
|
149
|
Gravdahl GB, Aakerøy L, Stovner LJ, Engstrøm M, Müller KI, Bjørk MH, Tronvik E. Continuous positive airway pressure in cluster headache: A randomized, placebo-controlled, triple-blind, crossover study. Cephalalgia 2023; 43:3331024221128273. [PMID: 36620891 DOI: 10.1177/03331024221128273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
BACKGROUND Oxygen inhalation aborts cluster headache attacks, and case reports show the effect of continuous positive airway pressure. The aim of this study was to investigate the prophylactic effect of continuous positive airway pressure in chronic cluster headache. METHODS This was a randomized placebo-controlled triple-blind crossover study using active and sham continuous positive airway pressure treatment for chronic cluster headache. Patients entered a one month's baseline period before randomly being assigned to two months' active continuous positive airway pressure treatment followed by a four weeks' washout period and two months' sham continuous positive airway pressure or vice versa. Primary outcome measure was number of cluster headache attacks/week. RESULTS Of the 30 included participants (12 males, median age 49.5 years, min-max 20-66 years), 25 completed both treatment/sham cycles (two discontinued, three lost to follow-up). The median number of cluster headache attacks per week was reduced from 8.25 (0.75-89.75) attacks to 6.25 (0-56.00) attacks for active continuous positive airway pressure and to 7.50 (0.50-43.75) attacks for sham continuous positive airway pressure, but there was no difference in active versus sham (p = 0.904). One patient had a serious adverse event during active treatment, none occurred during sham treatment. CONCLUSIONS Continuous positive airway pressure treatment did not reduce the number of cluster headache attacks compared to sham treatment in chronic cluster headache patients. TRIAL REGISTRATION CLINICALTRIALS.GOV NCT03397563.
Collapse
|
150
|
Qian ZJ, Howard JM, Cohen SM, Jin MC, Bhargava S, Cheng AG, Valdez TA. Use of Polysomnography and CPAP in Children Who Received Adenotonsillectomy, US 2004 to 2018. Laryngoscope 2023; 133:184-188. [PMID: 35285524 DOI: 10.1002/lary.30103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 02/02/2022] [Accepted: 03/02/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVES 1) To determine the prevalence polysomnogram (PSG) and continuous positive airway pressure (CPAP) therapy use in children who received adenotonsillectomy (AT) for sleep symptoms. 2) To identify health care disparities in these regards. STUDY DESIGN Retrospective database analysis. METHODS This study used data from Optum (Health Services Innovation Company) to identify 92,490 children who received AT for sleep symptoms between 2004 and 2018. Prevalence of preoperative PSG and postoperative PSG and CPAP were described. Clinical and demographic characteristics were compared between children who had preoperative PSG and those who did not. Characteristics of children with trisomy 21 (T21) were compared to assess PSG and CPAP use in a high-risk cohort. Predictive modeling was used to identify patient characteristics associated with postoperative PSG and CPAP use. RESULTS Preoperative PSG was obtained in 5.5% of children overall and 33.2% of children with T21. Male sex, obesity, other medical comorbidities, non-White race/ethnicity, and higher parent education were associated with preoperative PSG. Fewer than 3% of children received postoperative PSGs and approximately 3% went on to receive CPAP therapy postoperatively. Multiple logistic regression showed that age at surgery, male sex, obesity, other medical comorbidities, non-White race/ethnicity, and higher parent education were associated with postoperative PSG and CPAP use. CONCLUSIONS AND RELEVANCE This study described the prevalence pre-AT PSG use and post-AT PSG and CPAP use for persistent symptoms and identified sleep health care disparities in these regards. These results show that increased, equitable access to PSG is needed in children, particularly in the workup and treatment persistent symptoms after AT. LEVEL OF EVIDENCE 4 Laryngoscope, 133:184-188, 2023.
Collapse
|