1
|
Kara Ö, Sübay RK. In Vivo and In Vitro Accuracy and Precision Evaluations of Mini Electronic Apex Locators. AUST ENDOD J 2025. [PMID: 40366060 DOI: 10.1111/aej.12946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2025] [Revised: 04/15/2025] [Accepted: 04/24/2025] [Indexed: 05/15/2025]
Abstract
This study was aimed to evaluate in vivo and in vitro accuracy and precision of Root ZXMini, Raypex6 and PropexPixi electronic apex locators (EALs) in both dry and wet conditions (5.25% NaOCl, sterile saline, 2% chlorhexidine, 17% EDTA). Fifty vital maxillary and mandibular incisors were included in in vivo, and 50 maxillary central incisors were used in the in vitro study. Measurements were classified as successful if stable electronic working lengths (EWLs) were within ±0.5 mm of actual working length (AWL). Statistics were performed using paired sample t-test, Kruskal-Wallis test and Chi-Square (p < 0.05). No significant differences in precision, accuracy and success rates were found among EALs (p > 0.05). Root ZXMini and Raypex6 could directly detect a 0.5 mm coronal zone than major apical foramen (MAF) in both settings. After a 0.5 mm reduction as recommended by the manufacturer, Propex Pixi in vivo EWLs could be between AWL and MAF; in vitro EWLs could be within 0.5 mm coronal than AWL.
Collapse
Affiliation(s)
- Özlem Kara
- Department of Endodontics, Istanbul Provincial Directorate of Health Okmeydani Oral and Dental Health Hospital, Istanbul, Türkiye
| | - Rüstem Kemal Sübay
- Istanbul University, School of Dentistry, Department of Endodontics, Istanbul, Türkiye
| |
Collapse
|
2
|
Çelebi Keskin İS, Yalçın TY. Evaluation of heated sodium hypochlorite's effect on the accuracy of contemporary electronic apex locators: an in vitro study. BMC Oral Health 2025; 25:634. [PMID: 40275207 PMCID: PMC12023619 DOI: 10.1186/s12903-025-06003-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2025] [Accepted: 04/15/2025] [Indexed: 04/26/2025] Open
Abstract
BACKGROUND Accurate determination of the working length (WL) is essential for successful root canal therapy. Although electronic apex locators (EALs) are widely used for this purpose, the impact of irrigant temperature on their precision remains poorly understood. Therefore, in this study, we investigated the effect of variations in sodium hypochlorite (NaOCl) temperature on the performance of modern EALs, with particular emphasis on the recently introduced EAL, Ai-Pex. METHODS Twenty extracted human teeth were embedded in alginate to simulate clinical conditions. WL was measured using four EALs (Root ZX Mini, Propex Pixi, Raypex 6, and Ai-Pex) under three NaOCl temperature conditions: 19.4 °C (± 1.5 °C), 36 °C, and 70 °C. A dental operating microscope was used to determine the actual working length (AWL). Deviations between electronic and AWLs were recorded, and statistical analyses were conducted using repeated-measures analysis of variance (ANOVA) and chi-square tests. RESULTS All EALs exhibited high accuracy, with deviations within ± 0.5 mm of AWL across all NaOCl temperature conditions (p > 0.05). Ai-Pex achieved 95% accuracy at room and body temperatures and 100% accuracy at 70 °C. Similarly, Root ZX Mini, Propex Pixi, and Raypex 6 demonstrated consistent performance, with no statistically significant differences in accuracy across temperature groups. CONCLUSIONS This study confirms that variations in NaOCl temperature do not significantly impact the accuracy of EALs in determining the WL for root canal therapy. These findings underscore the reliability of contemporary EALs under different clinical conditions, including the newly evaluated Ai-Pex. Further, in vivo studies are necessary to validate these results.
Collapse
Affiliation(s)
- İkbal Sena Çelebi Keskin
- Department of Endodontics, Faculty of Dentistry, Istanbul Medeniyet University, Orhanlı Campus, Tuzla, Istanbul, 34956, Türkiye.
| | - Turgut Yağmur Yalçın
- Department of Endodontics, Faculty of Dentistry, Istanbul Medeniyet University, Orhanlı Campus, Tuzla, Istanbul, 34956, Türkiye
- Department of Endodontics, Faculty of Dentistry, Istanbul University, Istanbul, Türkiye
| |
Collapse
|
3
|
Ordinola-Zapata R, Azevedo B, Tataryn RW, Versiani MA. Maxillary Dental Anatomy and Physiology: Endodontic and Periodontal. Otolaryngol Clin North Am 2024; 57:927-939. [PMID: 39214739 DOI: 10.1016/j.otc.2024.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
The maxillary sinus floor is formed by the alveolar process of the maxilla. Frequently, the roots of maxillary molars and premolars may protrude into the sinus cavity, with only a thin membrane separating them. Endodontic infections are characterized by mixed biofilms of anaerobic and proteolytic bacteria that can infect the root canal space and accessory anatomy of those teeth producing apical periodontitis. Due to the close relationship with the maxillary sinus, the persistence of apical periodontitis could potentially lead to odontogenic sinusitis. Understanding maxillary sinus anatomy and its relationship with the posterior maxillary dentition is crucial for diagnosing this entity.
Collapse
Affiliation(s)
- Ronald Ordinola-Zapata
- Division of Endodontics, University of Minnesota School of Dentistry, Minneapolis, MN, USA.
| | - Bruno Azevedo
- Albert Einstein Medical Center, Department of Dental Medicine, Philadelphia, PA, USA
| | - Roderick W Tataryn
- Private Practice Endodontics, Spokane, WA, USA; Department of Endodontics, Loma Linda University, Loma Linda, CA, USA
| | - Marco Aurelio Versiani
- Department of Oral Health, Brazilian Military Police, Dental Specialty Center, Belo Horizonte, MG, Brazil
| |
Collapse
|
4
|
Furlan RD, Alcalde MP, Vivan RR, Klymus ME, Limoeiro AG, Duarte MA, de Vasconcelos BC. Influence of Different Apical Foramen Morphologies on the Accuracy of Four Electronic Foramen Locators. Eur J Dent 2024; 18:1101-1106. [PMID: 38698613 PMCID: PMC11479720 DOI: 10.1055/s-0044-1782214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024] Open
Abstract
OBJECTIVE The aim of this study was to evaluate the accuracy of the Root ZX II (RZX), Raypex 6 (RAY), EPex Pro (EPEX), and CanalPro (CNP) electronic foramen locators (EFLs) in different foraminal morphologies (fully formed foramen, immature foramen with parallel walls, and immature foramen with divergent walls); this article also evaluated the influence of different penetration levels (0.0 mm and -1.0 mm). MATERIALS AND METHODS Thirty single-rooted human premolars were accessed and had their cervical/middle thirds prepared with SX ProTaper files. The apical foramens (AF) were standardized to 250 µm and the initial root canal length (RCL1) was measured under 16x magnification with aid of a digital caliper. Using the alginate model, electronic measurements (EM) were taken 1.0 mm up to AF (EM1/-1) and at AF (EM1/0), always using adjusted hand K-files. The root apexes were then cross-sectioned 3.0 mm from the foramen; then, new RCL (RCL2) and electronic measurements were performed (EM2/-1 and EM2/0.0). Finally, retropreparations were performed with instruments SX ProTaper files introduced 4.0 mm in the apicocervical direction. Then new RCL (RCL3) and electronic measurements (EM3/-1 and EM3/0) were performed. STATISTICAL ANALYSIS Values were tabulated and tested for normality using the Shapiro-Wilk test, which yielded nonparametric distributions of the data. Data were subjected to the Kruskal-Wallis and Dunn tests to estimate possible differences between devices as a function of foramen morphology and/or apical limit. The significance level was set at 5.0%. RESULTS In general, the EFLs were accurate in determining the RCL. Statistically significant differences were observed between EPEX and RAY at 0.0, when measuring the divergent AF canals (p < 0.05). Regarding the different foramen morphologies in each EFL, RZX and EPEX showed no interference (p > 0.05), whereas RAY and CNP had lower accuracy levels at 0.0 with divergent AF (p < 0.05). CONCLUSION The four devices evaluated are accurate to determine the RCL in the conditions tested. The apical limit of penetration did not have significant influence on their accuracy. Conversely, the presence of divergence in the AF walls negatively influenced de RAY and CNP precisions at the foraminal level.
Collapse
Affiliation(s)
- Renan D. Furlan
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Murilo P. Alcalde
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Rodrigo R. Vivan
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Michel E. Klymus
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Ana G.S. Limoeiro
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Marco A.H. Duarte
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Bruno C. de Vasconcelos
- Post-Graduate Program in Dentistry, School of Pharmacy, Dentistry and Nursing, Federal University of Ceará, Fortaleza, Ceará, Brazil
- School of Dentistry of Sobral, Federal University of Ceará, Campus Sobral, Sobral, CE, Brazil
| |
Collapse
|
5
|
Koç S, Harorlı H, Kuştarcı A. In vitro evaluation of the accuracy of electronic apex locators and cone-beam CT in the detection of oblique root fractures. Dentomaxillofac Radiol 2024; 53:509-514. [PMID: 39037939 DOI: 10.1093/dmfr/twae037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 05/28/2024] [Accepted: 06/23/2024] [Indexed: 07/24/2024] Open
Abstract
OBJECTIVES This study aimed to compare the accuracy of cone-beam CT (CBCT) scanning and 3 different electronic apex locators (EALs) in the detection of simulated oblique root fractures (ORF) in different localizations. METHODS The study utilised a total of 80 human maxillary incisors, which were categorised into two groups based on the location of the ORF (apical and middle third of the root) formed on the buccal side of the root surface. The measurement of the distance between the incisal edge and the intersection of the ORF with the root canal was conducted using a stereomicroscope. This measurement is referred to as the actual working length (AWL). Additionally, three EALs-Dentaport ZX, EndoRadar Pro, and Propex II-were utilised to determine the electronic working length (EWL). Furthermore, CBCT images were employed to assess the distance, known as the CBCT working length (CWL). The differences were determined by subtracting AWL from EWL and CWL. RESULTS Based on the accuracy of the devices, there were no significant differences observed among Dentaport ZX, EndoRadar, Propex II, and CBCT measures in both the apical and middle third ORF groups, within the acceptable range of 0.5 and 1 mm. CONCLUSIONS The accuracy of Dentaport ZX, Propex II, and CBCT was higher in the middle third ORF group compared to the apical third ORF group, with a tolerance of 0.5 mm. However, there were no significant differences seen among the devices.
Collapse
Affiliation(s)
- Simay Koç
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, 07070, Turkey
- Department of Medical Biotechnology, Health Sciences Institute, Akdeniz University, Antalya, 07070, Turkey
| | - Hatice Harorlı
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, 07070, Turkey
| | - Alper Kuştarcı
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, 07070, Turkey
| |
Collapse
|
6
|
Bhagat E, Agnihotri Y, Das A, Das S, Panda S, Hota S. Accuracy of an Electronic Apex Locator (EAL) in Measuring the Working Length of Root Canals in Comparison With Radiographs: An In Vivo Study. Cureus 2024; 16:e60283. [PMID: 38872664 PMCID: PMC11173343 DOI: 10.7759/cureus.60283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/14/2024] [Indexed: 06/15/2024] Open
Abstract
INTRODUCTION Traditionally, radiographs were used to assess the working length of root canals. However, the use of Electronic Apex Locators (EAL) may be a non-invasive alternative. This study aimed to evaluate the accuracy of the electronic apex locator (EAL) compared to radiographic measurements in determining the working length of root canals. METHOD The study assessed the performance of EALs in different scenarios, including the presence of blood and pulp tissue, the use of ethylenediaminetetraacetic acid (EDTA), sodium hypochlorite (NaOCl) as an irrigant, and post-instrumentation with normal saline. An electronic apex locator (DTE DPEX-V; Woodpecker, China) was used alongside traditional radiographs to measure the working length in 144 root canal treatments. Bland-Altman analysis was used to compare the measurements between EAL and radiographs using Jamovi software, v2.4.8 (https://www.jamovi.org/). RESULT The findings revealed strong correlations between EAL and radiographic measurements across all testing environments, with Pearson's correlation coefficients ranging from 0.944 to 0.998. The Bland-Altman analysis suggests bias; the average difference was negative and close to zero (Pulp: -0.354, EDTA: -0.0972, NaOCl: -0.0382, Saline: -0.0139) when EAL measurements were compared to radiographic measurements. CONCLUSION The working length measurement of root canals using an electronic apex locator such as DTE DPEX-V is comparable to traditional radiographic measurements. The use of irrigants improves the measurement. The EAL has the potential to be an alternative to the invasive radiograph for root canal length measurement.
Collapse
Affiliation(s)
- Esha Bhagat
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| | - Yoshaskam Agnihotri
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| | - Abhisek Das
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| | - Sambarta Das
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| | - Swagat Panda
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| | - Sudeepta Hota
- Conservative Dentistry and Endodontics, Hi-Tech Dental College and Hospital, Bhubaneswar, IND
| |
Collapse
|
7
|
Eren İ, Sarıyılmaz Ö, Eren H, Sarıyılmaz E, Uslu G. Can ultrasonography be used to determine working length in endodontic treatment? An in vitro study. Odontology 2024; 112:453-459. [PMID: 37819467 DOI: 10.1007/s10266-023-00858-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 09/21/2023] [Indexed: 10/13/2023]
Abstract
This study was conducted to evaluate efficacy of ultrasonography (USG) in determining working length in in-vitro conditions. Twenty five access cavities of maxillary incisor teeth were opened and actual working lengths (AWL) were measured with dental operating microscope. The working length were then measured with an electronic apex locator and USG. USG and apex locator measurements were statistically analyzed using one sample t-test and compared with AWL. The mean AWL measurment was 20.68 mm. USG measured the working length slightly longer (21.09 mm) than the measurements of apex locator (20.64 mm). Statistical analysis showed that the USG method provided similar measurements to electronic apex locators and with no statistical difference with actual working length (P < .05). USG emerges as a promising method for working length measurement that allows simultaneous visualization of root tip anatomy in cases where electronic apex locators may be insufficient and there is buccal cortical bone loss.
Collapse
Affiliation(s)
- İrem Eren
- Faculty of Dentistry, Department of Endodontics, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Öznur Sarıyılmaz
- Faculty of Dentistry, Department of Endodontics, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Hakan Eren
- Faculty of Dentistry, Department of Dentomaxillofacial Radiology, Çanakkale Onsekiz Mart University, Kepez Çanakkale TR, Sahilyolu Cd No:5, 17100, Çanakkale, Turkey.
| | - Evren Sarıyılmaz
- Faculty of Dentistry, Department of Endodontics, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Gülşah Uslu
- Private Practice, Idadent Diş Kliniği, Çanakkale, Turkey
| |
Collapse
|
8
|
Monisha R, Sivakumar A, Chittrarasu M, Sampath SJ, Soundappan SP, Benny R. Comparative evaluation of accuracy of working length determination with fifth-generation apex locator using two different techniques: An in vitro study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:240-245. [PMID: 38634026 PMCID: PMC11019798 DOI: 10.4103/jcde.jcde_210_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 11/15/2023] [Accepted: 12/05/2023] [Indexed: 04/19/2024]
Abstract
Context Accurate working length (WL) determination is essential for successful root canal therapy. Aim The aim of this study was to compare the difference between two different techniques in locating minor constriction using fifth-generation electronic apex locator. Settings and Design A detailed protocol explaining the procedures of the study was submitted to the institutional ethics committee. Subjects and Methods Forty extracted human permanent canine teeth were selected. WL was measured three times for each sample by three different examiners for both the conventional and experimental techniques at different time intervals. Interexaminers were blinded to their measurements, and the person who analyzed mean value was also blinded with techniques. Finally, radiographic working length was obtained using 15 size K-file. A size 20 K-file was cemented into the measured position with glass ionomer cement. Each tooth was viewed under a stereomicroscope at ×40 magnification. The distance from the file tip to the root apex was measured and calibrated to the nearest tenth of a millimeter. Statistical Analysis Used Using Stata statistical software (Version 17, Statacorp, College Station, Texas, USA). The agreement between raters and techniques was determined using intraclass correlation coefficient "ICC" and Bland-Altman plot. Results The "experimental method" (0.95, 95%) showed better agreement between the raters in comparison with the "conventional method" (0.93, 95%). Conclusions The experimental technique showed perfect agreement between examiners in locating the minor constriction of the apical foramen.
Collapse
Affiliation(s)
- R Monisha
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Andamuthu Sivakumar
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - M Chittrarasu
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Sivakumar Jambai Sampath
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Saravana Priyan Soundappan
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Reveena Benny
- Department of Conservative Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| |
Collapse
|
9
|
Marceliano-Alves MF, Amoroso-Silva P, Alves FRF, Soimu G, Provenzano JC, Campello AF, Duarte ML, Moreno JO, Sierra-Cristancho A, Calle JT, Rôças IN, Siqueira JF. Multipopulation evaluation of the internal morphology of mandibular first premolars from different South American countries. A micro-computed tomography study. Arch Oral Biol 2023; 156:105809. [PMID: 37832245 DOI: 10.1016/j.archoralbio.2023.105809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 09/14/2023] [Accepted: 09/24/2023] [Indexed: 10/15/2023]
Abstract
OBJECTIVE To evaluate and compare several anatomical parameters of mandibular first premolars from individuals from different Latin American countries using micro-computed tomography. DESIGN Five hundred extracted mandibular first premolars from Brazilian, Argentinian, Chilean, Colombian, and Ecuadorian individuals were scanned using micro-computed tomography (n = 100 teeth/country). Root canal configurations were classified according to established parameters. Analyses also included: canal volume and surface area, structure model index, distances from the apical foramen to the root apex or the cementoenamel junction, major/minor apical canal diameters, canal orifice shape, and prevalence of ramifications. RESULTS A single root was the most common anatomy in all countries (range, 97%-100%). Vertucci's type-I canal was the most frequent configuration (range, 36%-66%), followed by C-shaped and type-V canals. The oval-shaped canal orifice was the most predominant in all countries (range, 34%-58%), followed by the circular shape (range, 16%-47%). C-shaped canals occurred in all subpopulations (range, 14%-26%), always associated with radicular grooves. Ranges for canal ramifications were as follows: accessory canals, 36%-73%; lateral canals, 4%-12%; and apical delta, 4%-14% of the teeth. Many anatomic parameters differed significantly between countries (P < .05). CONCLUSIONS Vertucci's types-I and -V, and C-shaped canals were the most prevalent configurations in the subpopulations investigated. Accessory canals and several complex anatomies were found, with some significantly different frequencies between countries.
Collapse
Affiliation(s)
| | - Pablo Amoroso-Silva
- Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - Flávio R F Alves
- Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil.
| | - Giuliana Soimu
- Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - José C Provenzano
- Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - Andrea F Campello
- Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | | | - Jaime O Moreno
- Dental School, Santo Tomás University, Bucaramanga, Colombia
| | | | | | - Isabela N Rôças
- Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - José F Siqueira
- Department of Endodontics, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| |
Collapse
|
10
|
Harorlı H, Koç S, Kuştarcı A. In Vitro Comparison of the Accuracy of Cone-Beam Computed Tomography Scanning and Electronic Apex Locators in Detection of Simulated Root Perforations in Different Localizations. J Endod 2023; 49:1676-1681. [PMID: 37739340 DOI: 10.1016/j.joen.2023.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/12/2023] [Accepted: 09/13/2023] [Indexed: 09/24/2023]
Abstract
INTRODUCTION This study aimed to compare the accuracy of cone-beam computed tomographic (CBCT) scanning and 2 different electronic apex locators (EALs) in the detection of simulated root canal perforations in different localizations. METHODS Eighty human mandibular premolars were prepared and divided into 2 groups according to the localization of the perforation area, having a 1-mm diameter. The distance between the occlusal edge and the beginning of the perforation was measured under a stereomicroscope (actual working length) using 2 EALs (Propex II [Dentsply Maillefer, Ballaigues, Switzerland] and Dentaport ZX [J. Morita, Tokyo, Japan]) (electronic working length) and CBCT images (CBCT working length). The calculations were made by subtracting the actual working length from the electronic working length and the CBCT working length to determine the differences. RESULTS In the apical third perforation group, there was a significant difference between Dentaport ZX and CBCT imaging. There was no significant difference between Dentaport ZX and Propex II and Propex II and CBCT measurements. In the middle third perforation group, Propex II was significantly more successful than CBCT imaging. In addition, there was no significance between the accuracy of Propex II in detecting the perforation area between the apical third perforation group and the middle third perforation group. CBCT imaging was more accurate in detecting the perforation area in the apical third perforation group than in the middle third perforation group. CONCLUSIONS In cases in which the root canal perforation was in the apical third of the root, both the EAL and CBCT imaging were successful in determining the perforation area, whereas the success rate of all devices used in this study decreased when the perforation area was in the middle third of the root.
Collapse
Affiliation(s)
- Hatice Harorlı
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | - Simay Koç
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey.
| | - Alper Kuştarcı
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| |
Collapse
|
11
|
Srivastav A, Chandra R, Siddiqui S, Chowdhary D, Katiyar A, Khan RA. Evaluation of Different Techniques of Working Length Determination in Comparison with CBCT. Indian J Dent Res 2023; 34:405-409. [PMID: 38739821 DOI: 10.4103/ijdr.ijdr_404_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 11/01/2023] [Indexed: 05/16/2024] Open
Abstract
AIM To estimate the working length of teeth using conventional tactile technique, radiovisiography technique, Apex locator, and confirmation of working length by cone beam computed tomography technique. MATERIALS AND METHODS Forty patients with the age group between 20 and 50 years with irreversible pulpitis were included in this study. After taking a preoperative radiograph, the procedure was started. The cavity wall buildup was done using composite in the cases needed and then rubber dam application was done. The working length of mesiobuccal and mesiolingual canal was taken using cone beam computed tomography and this was considered as the standard value. Then using tactile method, length of the canal was measured using radiovisiographic software followed by apexlocator. RESULT The Apex locator has showed best result as compared to tactile and radiovisiography. CONCLUSION Apex locator values were closest to cone beam computed tomography working length measurement values and electronic apexlocator can be used efficiently as an alternative method for working length determination. The quality of various techniques according to ranks of working length determination was found to be Cone beam computed tomography (CBCT) > Apexloc > Radiovisiography (RVG) > Tactile. Thus, Apex locator can be used as an alternative to cone beam computed tomography for working length determination.
Collapse
Affiliation(s)
| | - Ramesh Chandra
- Department of Conservative Dentistry and Endodontics, Career Postgraduate Institute of Dental Sciences and Hospital, Lucknow, Uttar Pradesh, India
| | - Shazia Siddiqui
- Department of Conservative Dentistry and Endodontics, Career Postgraduate Institute of Dental Sciences and Hospital, Lucknow, Uttar Pradesh, India
| | - Divya Chowdhary
- Department of Conservative Dentistry and Endodontics, ITS Centre for Dental Studies and Research, Muradnagar, Ghaziabad, Uttar Pradesh, India
| | - Alpana Katiyar
- Department of Pedodontics and Preventive Dentistry, Maharana Pratap Dental College and Hospital, Kanpur, Uttar Pradesh, India
| | - Rehan Ahmad Khan
- Department of Conservative Dentistry and Endodontics, Mithila Minority Dental College and Hospital, Darbhanga, Bihar, India
| |
Collapse
|
12
|
Nam J, Piasecki L, Kwak D, Hong JH, Jung IY, Park SH, Cho SY. Variations in the morphology of apical constriction affecting electronic readings: An in vitro investigation using 3D-printed tooth models. AUST ENDOD J 2023; 49 Suppl 1:245-252. [PMID: 36448774 DOI: 10.1111/aej.12724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 11/05/2022] [Accepted: 11/21/2022] [Indexed: 09/17/2023]
Abstract
We investigated the interference of apical constriction position and diameter on the accuracy of electronic apex locators using 3D-printed tooth models. Single-rooted tooth models with the same length, canal taper and major foramen, but variation in apical constriction position or size, were designed and 3D-printed. A mounting model was custom-made for precise measurement of both marks (0.5 and APEX/0.0) of two electronic apex locators. The electronic measurements of both devices were correlated significantly to the major foramen rather than apical constriction. The mean measurements of the group with 0.45 mm in apical constriction width were significantly shorter than those of the other groups for both marks of the two devices (p < 0.05). The variations in apical constriction position and width negatively affected the precision of the 0.5 mark of the tested devices. The 0.0 or APEX mark was consistently located the major foramen.
Collapse
Affiliation(s)
- Juhee Nam
- Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea
| | - Lucila Piasecki
- Department of Periodontics and Endodontics, School of Dental Medicine, University at Buffalo, Buffalo, New York, USA
| | - Doun Kwak
- Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea
| | - Jung Hwa Hong
- Department of Policy Research Affairs, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea
| | - Il-Young Jung
- Microscope Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, South Korea
| | - Sung-Ho Park
- Microscope Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, South Korea
| | - Sin-Yeon Cho
- Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea
| |
Collapse
|
13
|
Koç S, Kuştarcı A, Er K. Accuracy of different electronic apex locators in determination of minimum Root perforation diameter. AUST ENDOD J 2023; 49 Suppl 1:179-186. [PMID: 36354104 DOI: 10.1111/aej.12711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/17/2022] [Accepted: 11/01/2022] [Indexed: 11/11/2022]
Abstract
This study aims to evaluate the ability of Raypex 6, Propex Pixi, Dentaport ZX, Apex ID, Propex II and Dr.'s Finder NEO to detect minimum root canal perforation diameter. One hundred single-rooted, extracted human teeth were artificially perforated by 5 burs in different diameters (0.25-1.25 mm) in 5 mm above the apex. Twenty teeth were assigned to each group. The actual canal lengths (AL) were measured under stereomicroscope followed by a measurement of electronic canal length (EL) using each electronic apex locator (EAL). None of the EALs were able to detect the perforation at diameters of 0.50 and 0.25 mm. Although all EALs used in our study were unable to detect perforations at diameters of 0.5 mm and 0.25 mm, they were highly successful in the determination of simulated root perforations at diameters of 1.25, 1 and 0.75 mm.
Collapse
Affiliation(s)
- Simay Koç
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | - Alper Kuştarcı
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | - Kürşat Er
- Department of Endodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| |
Collapse
|
14
|
Alothmani OS, Siddiqui AY. Accuracy of Root ZX Electronic Apex Locator in Relation to Two Different Employment Protocols: An In Vitro Study. Cureus 2023; 15:e44659. [PMID: 37671079 PMCID: PMC10476874 DOI: 10.7759/cureus.44659] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/04/2023] [Indexed: 09/07/2023] Open
Abstract
Objective The aim of this study is to determine the apical level of the root canal, whether it is the apical foramen or a level coronal to it, that Root ZX (J. Morita Co., Kyoto, Japan) targets and to identify its employment protocol that provides better accuracy. Methods Actual lengths (ALs) of 75 extracted single-rooted teeth were obtained by inserting a K-file size 8 until its tip was in level with the most coronal border of the apical foramen. Reference length (RL) was calculated by deducting 0.5 mm from AL. Roots were placed in porous sponge block soaked with Ringer's solution, and canals were irrigated with 2 mL of 5% sodium hypochlorite. The blinded operator used Root ZX to measure lengths with K-file size 8. In the first tested employment protocol, the file was advanced to the "APEX mark" of the digital display, and the length was obtained. The second employment protocol followed the manufacturer's recommendations by inserting the file until the "APEX mark" followed by its withdrawal to the "0.5 mark." Stability of the digital meter for 5 seconds was mandatory before recording the lengths. All measurements were repeated one week later and then both measurements were averaged to represent "APEX mark" and "0.5 mark," respectively. Data were analyzed using t-test, with significance set at 0.05. Results Regardless of the employment protocol, most registered lengths were longer than targeted. The mean "APEX mark" was significantly longer than the mean AL (P=0.000), and the mean "0.5 mark" was significantly longer than the mean RL (P=0.000). Although the mean "0.5 mark" was longer than the mean AL, the difference was not significant (P=0.07). Conclusion The apical level of the root canal targeted by the Root ZX was the apical foramen. The most accurate employment protocol to achieve that is to use the Root ZX according to the manufacturer's recommendations.
Collapse
Affiliation(s)
| | - Amna Y Siddiqui
- Department of Endodontics, King Abdulaziz University, Jeddah, SAU
| |
Collapse
|
15
|
Cîmpean SI, Chisnoiu RM, Colceriu Burtea AL, Rotaru R, Bud MG, Delean AG, Pop-Ciutrilă IS. In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59050918. [PMID: 37241150 DOI: 10.3390/medicina59050918] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 05/02/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023]
Abstract
Background and Objectives: The aim of this study was to compare the accuracy of three types of electronic apex locators (EALs) when two different concentrations of NaOCl irrigation solutions are used by two operators. Materials and Methods: After creating the access cavities for 20 single rooted extracted teeth, the actual canal length (ACL) of each canal was determined visually using a #10 file and magnification. The teeth were subsequently inserted in plastic molds filled with alginate. The electronic measurement of root canal length (EWL) was performed using three different electronic apex locators: Root ZX II, Apex ID, and Dual Pex. Two independent operators, an endodontic specialist with 20 years practice and an undergraduate student in the final year of study, performed the irrigation procedures with two different concentrations of NaOCl (2% and 5.25%), and then measured the EWL using each of the EALs. The accuracy of all EALs, was determined in each case by subtracting the EWL from the ACL. Statistical analyses were performed using one-way ANOVA test. Results: In the presence of 2% NaOCl solution, for a margin error of ±0.5 mm, Root ZX II, Apex ID, and Dual Pex presented an accuracy of 90%, 80%, and 85% respectively. The increase in the concentration of the irrigation solution affected the accuracy of Root ZX II and Apex ID for both operators, diminishing it to 75% for the same margin error, but improved Dual Pex's accuracy to 100%. Conclusions: The best accuracy in working length determination was obtained by Root ZX II for 2% NaOCl solution and by Dual Pex for 5.25% NaOCl solution with no significant statistical difference when compared.
Collapse
Affiliation(s)
- Sanda Ileana Cîmpean
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| | - Radu Marcel Chisnoiu
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| | - Adela Loredana Colceriu Burtea
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| | - Rareș Rotaru
- Student at Faculty of Dental Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400001 Cluj-Napoca, Romania
| | - Marius Gheorghe Bud
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| | - Ada Gabriela Delean
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| | - Ioana-Sofia Pop-Ciutrilă
- Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania
| |
Collapse
|
16
|
Siddiqui AY, Alothmani OS. Influence of Hand File Size on the Accuracy of Root ZX and iPex Electronic Apex Locators: An In Vitro Study. Cureus 2023; 15:e39662. [PMID: 37256168 PMCID: PMC10226783 DOI: 10.7759/cureus.39662] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/27/2023] [Indexed: 06/01/2023] Open
Abstract
OBJECTIVE To investigate the effect of the hand file size on the accuracy of Root ZX (J. Morita Co., Kyoto, Japan) and iPex (NSK, Tochigi, Japan). METHODS Seventy-five single-rooted teeth were decoronated, and canals were coronally flared with Gates Glidden burs sizes 4, 3, and 2. Actual canal length was determined by averaging two readings obtained by inserting K-file size 8 until its tip was apparent at the most coronal border of the apical foramen. The reference length was actual length-0.5 mm. The blinded operator utilized Root ZX and iPex following the manufacturer's recommendations. Teeth were placed in sponge blocks soaked with Ringer's solution. Canals were irrigated with 5% sodium hypochlorite. K-file size 8 was attached to the lip clip and introduced until the APEX/0.0 mark, then withdrawn to the 0.5 mark. A stable meter gauge for five seconds indicated an acceptable reading. Readings with sizes 10 and 15 were obtained afterward. All measurements were done twice, then averaged. Data analysis was done using ANOVA and a posthoc Bonferroni test with the significance level set at P<0.05. RESULTS For Root ZX, the mean length with size 8 was not significantly different from the mean reference length (P=0.205). The same was found for its mean length at size 10 (P=0.093). However, the mean Root ZX length with size 15 was significantly shorter than the mean reference length (P=0.019). Mean iPex lengths with sizes 8, 10, and 15 were all significantly shorter than the mean reference length (P=0.038, 0.006, and 0.02, respectively). CONCLUSION The size of the hand file affected the precision of Root ZX and iPex.
Collapse
Affiliation(s)
- Amna Y Siddiqui
- Department of Endodontics, King Abdulaziz University, Jeddah, SAU
| | | |
Collapse
|
17
|
León‐López M, Cabanillas‐Balsera D, Martín‐González J, Montero‐Miralles P, Saúco‐Márquez JJ, Segura‐Egea JJ. Prevalence of root canal treatment worldwide: A systematic review and meta-analysis. Int Endod J 2022; 55:1105-1127. [PMID: 36016509 PMCID: PMC9826350 DOI: 10.1111/iej.13822] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 08/21/2022] [Accepted: 08/22/2022] [Indexed: 01/11/2023]
Abstract
BACKGROUND The prevalence of root filled teeth (RFT) worldwide will inform about the amount of clinical activity of dentists dedicated to treat endodontic disease. OBJECTIVES To carry out a systematic review with meta-analysis answering the following question: What is the prevalence of RFT around the world? The percentage of people with at least one RFT was also investigated. METHODS A systematic review including population-based studies using the following databases: PubMed, EMBASE and Scielo. Studies related to prevalence of RFT were included. The outcome of interest of the study was the prevalence of RFT. The meta-analyses were calculated with the Open Meta Analyst software to determine the global prevalence of RFT. Subgroups analyses were performed comparing geographical distribution, radiographic method and year of the study (classified in 20th or 21th century). The prevalence of people with at least one RFT was also analysed. RESULTS Seventy-four population-based studies fulfilled the inclusion criteria. Twenty-eight, forty-four and two studies reported high, moderate and low risk of bias, respectively. No obvious publication bias was observed. Prevalence of RFT was estimated with 1 201 255 teeth and 32 162 patients. The calculated worldwide prevalence of RFT was 8.2% (95% CI = 7.3%-9.1%; p < .001). The global prevalence of people with at least one RFT was 55.7% (95% CI = 49.6%-61.8%; p < .001). In 20th century, the prevalence of RFT was 10.2% (95% CI = 7.9%-12.5%; p < .001), whereas in the 21st century the overall calculated prevalence of RFT was 7.5% (95% CI = 6.5%-8.6%; p < .001). Brazilian people (12%) and the European population (9.3%) showed the highest prevalence of RFT. In Europe, 59.6% (95% CI = 52.4%-66.8%) of people has at least one RFT. CONCLUSIONS This review showed that root canal treatment is a very common therapy throughout the world. More than half of the studied population have at least one RFT. A limitation of the present study is that most of the studies did not consider random sampling for population selection. REGISTRATION PROSPERO Systematic review registration number: (CRD42022329053).
Collapse
Affiliation(s)
- María León‐López
- Endodontic Section, Department of Stomatology, School of DentistryUniversity of SevillaSevillaSpain
| | | | - Jenifer Martín‐González
- Endodontic Section, Department of Stomatology, School of DentistryUniversity of SevillaSevillaSpain
| | - Paloma Montero‐Miralles
- Endodontic Section, Department of Stomatology, School of DentistryUniversity of SevillaSevillaSpain
| | - Juan J. Saúco‐Márquez
- Endodontic Section, Department of Stomatology, School of DentistryUniversity of SevillaSevillaSpain
| | - Juan J. Segura‐Egea
- Endodontic Section, Department of Stomatology, School of DentistryUniversity of SevillaSevillaSpain
| |
Collapse
|
18
|
Paiva HC, Akisue E, de Miranda Candeiro GT, de Lima Scardini I, Caldeira CL, Gavini G. Influence of heat treatment of nickel-titanium instruments on the accuracy of an electronic apex locator integrated with endodontic motor. J Conserv Dent 2022; 25:596-599. [PMID: 36591588 PMCID: PMC9795698 DOI: 10.4103/jcd.jcd_260_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 05/20/2022] [Accepted: 07/01/2022] [Indexed: 01/04/2023] Open
Abstract
Context Manufacturers have produced a wide variety of nickel-titanium (NiTi) alloys, but the available literature is limited on the accuracy of some integrated electronic apex locators (EAL) used with different NiTi heat treatments in working length (WL) determination. Aim This study aims to evaluate ex vivo , the influence of different heat treatments of NiTi instruments, and the diameter of the apical preparation on the accuracy of an EAL used during root canal preparation using an integrated EAL and motor unit. Materials and Methods Nineteen extracted human mandibular incisors were included in the study. The WL control was determined by the visual method. Instruments of Mtwo, Reciproc, Reciproc Blue, WaveOne Gold, Twisted File Adaptive, and Hyflex CM systems, with diameters from 0.25 mm to 0.50 mm, were used to measure WL during root canal preparation. The electrical resistivity of instruments with a diameter of 0.25 mm from each system was evaluated using an Inductance, Capacitance, and Resistance (LCR) meter. Statistical Analysis Used Data were statistically analyzed using Fisher's exact test and Kruskal-Wallis test. Results The different heat treatments and different diameters did not influence the precision of the EAL (P > 0.05). Conclusion The heat treatment and the diameter of the apical preparation did not influence the accuracy of WL determination by an EAL integrated with the endodontic motor.
Collapse
Affiliation(s)
| | - Eduardo Akisue
- Department of Endodontics, Santa Cecília University, Santos, São Paulo, Brazil
| | | | | | | | - Giulio Gavini
- Department of Endodontics, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
19
|
Pham VK, Pham TLK. Root canal length estimated by cone-beam computed tomography at different slice thicknesses, dedicated endodontic software, or measured by an electronic apex locator. Sci Rep 2022; 12:6531. [PMID: 35444163 PMCID: PMC9021240 DOI: 10.1038/s41598-022-10534-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 04/01/2022] [Indexed: 11/26/2022] Open
Abstract
The aim of the present study was to evaluate the agreements between the root canal length estimations using cone-beam computed tomography (CBCT) at different slice thicknesses, dedicated software, or an electronic apex locator (EAL) and the actual lengths (AL). In total, 111 extracted human molars with 302 root canals were chosen. Teeth were scanned using a CBCT device at a voxel size of 0.075 mm. Root canal lengths were estimated using CBCT software at different slice thicknesses (0.6, 1.2, and 2.4 mm) and dedicated software for proposed or operator lengths. The endodontic access cavities were created, and root canal lengths were estimated with an EAL for electronic length (EL) and a ruler for AL. Data were tested using paired t-tests and Bland-Altman plots to detect the differences between the methods in length estimation at a significance of 0.05. The accuracy in the range of ± 0.5 mm was 100% for the EAL. There was an agreement between the EL and CBCT at a slice thickness of 1.2 mm (p = 0.349). CBCT at the smallest slice thickness estimation was not the best modality in agreement with the AL. The EAL was an accurate and reliable method for root canal length measurement.
Collapse
Affiliation(s)
- Van-Khoa Pham
- Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
| | - Tran-Lan-Khue Pham
- Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
| |
Collapse
|
20
|
ElAyouti A, Connert T, Dummer PMH, Löst C. A critical analysis of research methods and experimental models to study working length determination and the performance of apex locators ‐ A narrative review with recommendations for the future. Int Endod J 2022; 55 Suppl 2:281-294. [DOI: 10.1111/iej.13738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 03/20/2022] [Accepted: 03/21/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Ashraf ElAyouti
- University of Tübingen Division of Endodontology Department of Conservative Dentistry and Periodontology Osianderstraße 2‐8 Tübingen 72076 Germany
| | - Thomas Connert
- University of Basel Department of Periodontology, Endodontology and Cariology Hebelstr. 3 Basel 5042 Switzerland
| | | | - Claus Löst
- University of Tübingen Conservative Dentistry and Endodontology Osianderstr. 2‐8 Tübingen 72076 Germany
| |
Collapse
|
21
|
MAZZI-CHAVES JF, LEONI GB, OLIVEIRA JS, SILVA-SOUSA YTC, SILVA RG, PAUWELS R, SOUSA-NETO MD. Influence of anatomical features in the endodontic treatment planning of maxillary anterior teeth. Braz Oral Res 2022; 36:e005. [DOI: 10.1590/1807-3107bor-2022.vol36.0005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 06/21/2021] [Indexed: 11/21/2022] Open
|
22
|
Yammine S. Root canal morphology and effects on root canal preparation. THE SAINT'S INTERNATIONAL DENTAL JOURNAL 2022. [DOI: 10.4103/sidj.sidj_5_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
23
|
Bin Rubaia'an MA, AbuHassna M, AlShahrani RK, Alghulikah K, Dahham Alsaffan A. Apexoconnection: A Novel Technique to Determine Working Length. Clin Cosmet Investig Dent 2021; 13:353-360. [PMID: 34429659 PMCID: PMC8380135 DOI: 10.2147/ccide.s316839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 08/06/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The aim of this study was to evaluate and compare the accuracy of working length (WL) determination when using the conventional electronic WL (EWL) technique versus using the novel Apexoconnection technique involving EWL with a connector (EWLc). Materials and Methods Sixty extracted posterior teeth with a total of 118 root canals were selected for the study. The real WL (RWL) of each canal was verified using a dental microscope under 25.6x magnification. Root canal lengths were measured with an apex locator using the attachment device directly attached to the hand file in the root canal and then adding another hand file as a connector between the attachment device and the file in the root canal. The distance from the file’s stopper to its tip was measured using a digital caliper. Statistical analysis was carried out to analyze the data between experimental groups. Results The results of the statistical test showed that the differences in the WL determined by either technique and the proper length as determined under the microscope were not statistically significant. The results of the statistical test comparing the groups were also not statistically significant. Conclusion In this in vitro study, both the novel and conventional techniques were equally accurate for determining WL when compared with the RWL.
Collapse
Affiliation(s)
| | - Mohammed AbuHassna
- Restorative Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia
| | - Rahaf K AlShahrani
- College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia
| | - Khaled Alghulikah
- Restorative Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia
| | - Abdulrahman Dahham Alsaffan
- Preventive Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
24
|
Bernardes RA, Feitosa APOP, Bramante CM, Vivan RR, Piasecki L, Duarte MAH, de Vasconcelos BC. Evaluation of foramen locating accuracy of an endodontic motor integrated with electronic foramen employing optimal glide path kinematics. Clin Oral Investig 2021; 26:1293-1298. [PMID: 34406466 DOI: 10.1007/s00784-021-04103-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 07/23/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE This study aimed to evaluate the accuracy of the auto apical function in the maintenance of the apical limit of instrumentation during glide path procedures when associated to OGP kinematics of Tri Auto ZX2, compared to the continuous rotation of the same motor, as well as Root ZX II and VDW Gold. MATERIALS AND METHODS Forty-eight extracted human mandibular single-rooted premolars were selected. After endodontic access, cervical pre-flaring was performed using size 30, 0.10 taper rotary instruments, and the apical foramen size was standardized to 200 μm. Teeth were randomly divided into four groups (n = 12) according to the device and kinematics. For all the groups, the Auto Apical Stop function (AAS) was set to the 0.0 mark. Glide path instruments size 25, .01 taper were activated inside the canals until the apical limit was reached. Then, the files were fixed with cyanoacrylate to the teeth and decoupled from the equipment. Data were statistically analyzed in GraphPad Prism 6.0 software with the significance set at 5% (Kruskal-Wallis tests). RESULTS There was no difference in the mean deviation between the groups. No significant difference was found among the groups when the distributions and percentages of differences between the file tip and the apical foramen were compared (P > 0.05). CONCLUSION The use of auto apical function at the 0.0 mark of all tested devices provided an adequate control of the apical limit during glide path preparation. Foramen locating accuracy of Tri Auto ZX2 in OGP kinematics was similar to those of Tri Auto ZX2, Root ZX II, and VDW Gold in continuous kinematics. CLINICAL RELEVANCE Clinical strategies in canal negotiation and glide path as OGP motion associated to electronic foramen locators could reduce iatrogenic risk of deviation and file fractures and create an easier initial preparation to facilitate endodontic procedures.
Collapse
Affiliation(s)
| | | | - Clovis Monteiro Bramante
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, São Paulo, Brazil
| | - Rodrigo Ricci Vivan
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, São Paulo, Brazil
| | - Lucila Piasecki
- Department of Periodontics & Endodontics, University At Buffalo, Buffalo, NY, USA
| | - Marco Antônio Hungaro Duarte
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, São Paulo, Brazil
| | - Bruno C de Vasconcelos
- Post-Graduate Program in Dentistry, Federal University of Ceará, Fortaleza, Ceará, Brazil. .,Post-Graduate Program in Dentistry, School of Pharmacy, Dentistry and Nursing, Federal University of Ceará, 1253 Monsenhor Furtado St, Fortaleza, CE, CEP 60430-355, Brazil.
| |
Collapse
|
25
|
Cury MTS, Vasques AMV, Bueno CRE, Machado T, Trizzi JQ, Santana VDS, Dezan-Júnior E. Accuracy of Root ZXII, E-PEX and FIND apex locators in teeth with vital pulp: an in vivo study. Braz Oral Res 2021; 35:e080. [PMID: 34190773 DOI: 10.1590/1807-3107bor-2021.vol35.0080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 11/11/2020] [Indexed: 11/22/2022] Open
Abstract
This research evaluated, in vivo, the accuracy of three electronic apex locators - EALs (Root ZXII, E-PEX and FIND) in teeth with vital pulp submitted to biopulpectomy, preserving the periodontal stump. For this study, 90 single-rooted teeth with extraction indication were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed. The cervical and middle thirds of root canals were instrumented with Reciproc R25, and the K#15 file was used as a standard instrument to determine working length, forming 2 groups: Constriction (insertion of the instrument until the apical constriction limit) and Foramen (insertion of the instrument until the foramen and then repositioning at constriction, without removing the file from the canal). The hand file was stabilized with a light-cured flow resin. After extraction, the samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis using Kruskal-Wallis and Dunn tests (p<0.05). There was a statistically significant difference in the abilities of the EALs to detect the apical constriction after reaching the foramen with Root ZX II showing higher accuracy (89%). However, there was no difference in the accuracy of the three EALs in detecting the apical constriction without reaching the foramen. Based on the present results, we conclude that EALs may show accurate measures in detecting apical constriction and foramen, even without damaging the periodontal stump in biopulpectomy.
Collapse
Affiliation(s)
- Marina Tolomei Sandoval Cury
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| | - Ana Maria Veiga Vasques
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| | | | - Thiago Machado
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| | - Juliana Quintino Trizzi
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| | - Vitor da Silva Santana
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| | - Eloi Dezan-Júnior
- Universidade Estadual Paulista "Júlio de Mesquita Filho" - Unesp, Araçatuba. School of Dentistry, Department of Endodontics, Araçatuba, SP, Brazil
| |
Collapse
|
26
|
Van Pham K. Endodontic length measurements using 3D Endo, cone-beam computed tomography, and electronic apex locator. BMC Oral Health 2021; 21:271. [PMID: 34006262 PMCID: PMC8130300 DOI: 10.1186/s12903-021-01625-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 05/10/2021] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND The objective of this study is to investigate the accuracy of the 3D Endo software, cone-beam computed tomography (CBCT) software, and the electronic apex locator (EAL) in endodontic length determination. METHODS 302 root canals in 111 human extracted molars were chosen. Access cavity was performed, and root canal lengths were measured with a digital caliper for actual length (AL) and EAL for electronic length. Teeth were then scanned using CBCT device at voxel size of 0.10 mm. It measured root canal lengths using the CBCT (Romexis Viewer), 3D Endo for proposed length (3D-PL) and correct length (3D-CL). Mean differences between the four methods with the AL were calculated and compared. Fisher's exact test, paired t-test, Bland-Altman plot were used to test the differences among the experimental modalities in working length determination at the significance of 0.05. RESULTS The accuracy in the range of ± 0.5 mm of the EAL ProPex II was highest among the experimental modalities, however this method disagreed with the actual length. CONCLUSIONS The correct working length after adjustment from the semi-automatically length by the 3D Endo software and Romexis Viewer measurements agreed with the AL.
Collapse
Affiliation(s)
- Khoa Van Pham
- Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, 652 Nguyen Trai Street, Ward 11, District 5, Ho Chi Minh City, Vietnam.
| |
Collapse
|
27
|
Van Pham K. Endodontic length measurements using cone beam computed tomography with dedicated or conventional software at different voxel sizes. Sci Rep 2021; 11:9432. [PMID: 33941828 PMCID: PMC8093273 DOI: 10.1038/s41598-021-88980-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 04/20/2021] [Indexed: 11/09/2022] Open
Abstract
The aim of this study is to investigate the accuracies and the agreements of the 3D Endo software, conventional CBCT software Romexis Viewer at three voxel sizes, and the EAL ProPex Pixi in endodontic length measurements. Three hundred and twenty-nine root canals in 120 intact human extracted molars were accessed. The actual lengths (AL) and electronic lengths (EL) were measured using the ruler and electronic apex locator (EAL), respectively. Teeth were scanned using the CBCT at different voxel sizes (0.075, 0.10, and 0.15 mm). Root canal lengths were measured using 3D Endo with proposed length (3D-PL) by software, corrected length (3D-CL), Romexis Viewer. The Fisher's exact test, paired t-test and Bland-Altman plots were calculated to detect the agreements of the four methods with AL measurements. The ProPex Pixi measurements obtained the highest accuracy in the range of ± 0.5 mm. There was agreement between the 3D-PL and the 3D-CL with AL measurements at voxel size of 0.15 mm and at voxel size of 0.10 mm, respectively. The CBCT Romexis Viewer measurements agreed with AL at three voxel sizes. The conventional CBCT measurements using Romexis Viewer and dedicated software did not reach to the 100% accuracy in the range of ± 0.5 mm.
Collapse
Affiliation(s)
- Khoa Van Pham
- Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, 700000, Vietnam.
| |
Collapse
|
28
|
Effect of Orthodontic Brackets on the Accuracy of Apex Locators: A Pilot Study. BIOMED RESEARCH INTERNATIONAL 2021; 2021:6615560. [PMID: 33987442 PMCID: PMC8093058 DOI: 10.1155/2021/6615560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 04/18/2021] [Accepted: 04/20/2021] [Indexed: 11/24/2022]
Abstract
The purpose of this study was to evaluate the effect of metal orthodontic brackets on the accuracy of electronic apex locator (EAL). The actual canal lengths (ACL) of 40 mandibular incisor teeth were determined. Then, the teeth were randomly divided into two groups (n = 20). Orthodontic metal brackets were applied in the first group, and no brackets, in the second group. The working length of each tooth was measured with an EAL under 3 test conditions according to the distance between the lip clip and sample tooth. Data were analyzed using one-way repeated measures analysis of variance and Tukey's post hoc tests (p = 0.05). In the bracketed samples, when the lip clip was located at 1 cm and 2 cm from the samples. The mean differences between the EAL measurements and ACLs were statistically higher than those when the samples were located 3 cm from the lip clip (p < 0.05). There were also statistically significant differences between EAL measurements and ACLs in the bracketed samples located 1 and 2 cm from the lip clip (p < 0.05). In the nonbracketed group, the differences between EAL measurements and ACLs were not statistically significant in the samples located 1, 2, and 3 cm from the lip clip (p > 0.05). Use of orthodontic metal brackets can negatively influence the accuracy of the electronic apex locator when the distance between the lip clip and bracket was short. A minimum of 3 cm distance should be kept between the lip clip and tooth in order to make consistent electronic measurements.
Collapse
|
29
|
Iparraguirre Nuñovero MF, Piasecki L, Segato AVK, Westphalen VPD, Silva Neto UX, Carneiro E. A laboratory study of the accuracy of three electronic apex locators: influence of embedding media and radiographic assessment of the electronic apical limit. Int Endod J 2021; 54:1200-1206. [PMID: 33683733 DOI: 10.1111/iej.13507] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 11/30/2022]
Abstract
AIM To evaluate several factors that might interfere with the use of electronic root canal length measurement devices (ERCLMDs) in a laboratory setting, including two different embedding media (alginate and electroconductive gel), three different types of devices and the radiographic view on the assessment of the electronic readings. METHODOLOGY Thirty single-rooted extracted human mandibular premolars were selected. After access and canal pre-flaring, a size 10 K-file was inserted in the canal up to the major apical foramen under magnification (×10), and this length was recorded as the actual length (AL) of the canal. Teeth were mounted on a specific endodontic training kit platform (ProTrain). Two different embedding media (electroconductive gel and alginate) and three different ERCLMDs: Apex ID (SybronEndo, Glendora, CA, USA), CanalPro Apex Locator (Coltene-Endo, Cuyahoga Falls, OH, USA) and the Root ZX II (J. Morita, Tokyo, Japan), were tested. Following the measurement at the 0.5 mark of each ERCLMD using alginate, two periapical radiographs (bucco-lingual and proximal views) were taken. The difference between the electronic readings and the AL, as well as the distance from the file tip to the apex of the roots on the radiographs, was calculated. Data were analysed statistically (two-way anova, Tukey's and chi-squared tests) at 5% significance level. RESULTS The incidence of over-extended readings was significantly greater (P < 0.05) when using the ProTrain electroconductive gel, except for Root ZX II at the 0.5 mark. Root ZX, CanalPro and Apex ID had similar accuracy when the 0.0/APEX mark was used to locate the foramen. For the radiographic method, no difference was found between the devices or radiographic views. CONCLUSION Compared with alginate, the conductive gel of the ProTrain kit negatively affected most of the electronic readings. The three evaluated ERCLMDs had similar accuracy in locating the apical foramen when using the mark 0.0/APEX and alginate as the embedding media. Although the ProTrain platform allows radiographs to be exposed in both bucco-lingual and proximal views, no difference was found between the views when evaluating the apical limit provided by the 0.5 mark in mandibular premolars embedded in alginate.
Collapse
Affiliation(s)
- M F Iparraguirre Nuñovero
- Department of Endodontics, Life Sciences School, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
| | - L Piasecki
- Department of Periodontics and Endodontics, University at Buffalo, New York, NY, USA
| | - A V K Segato
- Department of Endodontics, Life Sciences School, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
| | - V P D Westphalen
- Department of Endodontics, Life Sciences School, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
| | - U X Silva Neto
- Department of Endodontics, Life Sciences School, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
| | - E Carneiro
- Department of Endodontics, Life Sciences School, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
| |
Collapse
|
30
|
Suguro H, Nishihara A, Tamura T, Nakamura T, Toyama Y, Takeichi O. The use of micro-computed tomography to determine the accuracy of electronic working length with two apex locators. J Oral Sci 2021; 63:167-169. [PMID: 33731504 DOI: 10.2334/josnusd.20-0466] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE This study evaluated the precision of electronic working length by microcomputed tomography using two electronic apex locators (EALs). METHODS Twenty single-rooted permanent teeth without caries or restorations were selected as the subject teeth. The positions of the minor apical constriction (AC) and major apical foramen (AF) were measured by electronic root canal length, and microcomputed tomography was performed with the file inserted and fixed in the root canal. All teeth were measured individually and independently by two operators. The Mann-Whitney U-test was used to statistically test the AC and AF values using two EALs; P < 0.05 was defined as statistically significant. RESULTS This was 65.0% within 1.5 mm in the case of two EALs on AC. This was more than 90.0% within 1.0 mm in the case of two EALs on AF. Comparison of the differences between the respective AC and AF of the measurements obtained using the two EALs revealed no significant difference. CONCLUSION The two EALs are devices that can greatly improve the accuracy of WL control.
Collapse
Affiliation(s)
- Hisashi Suguro
- Department of Endodontics, Nihon University School of Dentistry.,Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry
| | - Anna Nishihara
- Division of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry
| | - Takahito Tamura
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Takeshi Nakamura
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Yurika Toyama
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Osamu Takeichi
- Department of Endodontics, Nihon University School of Dentistry.,Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry
| |
Collapse
|
31
|
Adorno CG, Solaeche SM, Ferreira IE, Pedrozo A, Escobar PM, Fretes VR. The influence of periapical lesions on the repeatability of two electronic apex locators in vivo. Clin Oral Investig 2021; 25:5239-5245. [PMID: 33580848 DOI: 10.1007/s00784-021-03831-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 02/05/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To determine the influence of periapical lesions on the repeatability of two electronic apex locators (EALs), Root ZX II, and RomiApex A-15, in maxillary anterior teeth, in vivo. MATERIALS AND METHODS After approval by the local ethics committee, 43 maxillary anterior teeth scheduled for root canal therapy were assigned to two groups. The periapical lesion (PAL) group included 21 teeth with necrotic pulps and radiographically visible periapical lesion, and the normal periapex (NPA) group consisted of 22 teeth with vital pulps and no periapical lesion. In each canal, Root ZX II and RomiApex A-15 were used to determine working length defined as the "zero" reading on the display. Two consecutive measurements were performed with each EAL on each tooth and a second operator measured the endodontic file with a digital caliper without knowledge of the EAL being used or the tooth diagnosis. The absolute value of the difference between the first and second measurement (measurement pairs) was calculated. Repeatability was evaluated by the Bland-Altman method, and an aligned ranks transformation ANOVA was conducted to compare the EALs. RESULTS The median absolute difference between measurement pairs was significantly lower (p < 0.001) and the limits of agreement were narrower in the NPA group. Among the EALs, median absolute differences were significantly smaller for Root ZX (p < 0.001). CONCLUSIONS Measurements were more repeatable when no periapical lesion was present. Root ZX showed better repeatability than RomiApex. CLINICAL RELEVANCE Periapical lesions seem to influence successive in vivo measurements with EALs.
Collapse
Affiliation(s)
- Carlos G Adorno
- Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay.
| | - Sandra M Solaeche
- Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay
| | - Ileana E Ferreira
- Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay
| | - Andrea Pedrozo
- Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay
| | | | - Vicente R Fretes
- Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay
| |
Collapse
|
32
|
Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study. Eur Endod J 2020; 5:226-230. [PMID: 33353910 PMCID: PMC7881377 DOI: 10.14744/eej.2020.30633] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective: The aim of this study was to compare the accuracy of three electronic apex locators (EALs) (Propex Pixi, Mini Root ZX, Raypex 5) in determining working length (WL) under different environments (existence of blood-pulp/sodium hypochlorite in root canal space) using micro-computed tomography (micro-CT) measurements. Methods: Twenty-five single-rooted human teeth that were scheduled for extraction were selected for the study. Measurements were performed with the Propex Pixi, Mini Root ZX, Raypex 5 in vivo conditions in the presence of NaOCl irrigant solution or blood-pulp tissue. After that the teeth were extracted and scanned using micro-CT. The measurements of WL obtained with the different EALs in different environments were statistically compared. Significance was set at P<0.05. Results: There were no significant differences among the WL measurements performed with EALs or micro CT groups under different clinical enviroments. All EALs tested gave reliable results in respect to apical constriction. Conclusion: The accuracy of the tested EALs is not affected by pulp tissues and blood or NaOCl.
Collapse
|
33
|
Shacham M, Levin A, Shemesh A, Lvovsky A, Ben Itzhak J, Solomonov M. Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study. BDJ Open 2020; 6:22. [PMID: 33298851 PMCID: PMC7670426 DOI: 10.1038/s41405-020-00052-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 10/22/2020] [Accepted: 10/26/2020] [Indexed: 12/04/2022] Open
Abstract
The aim of the current study was to determine the accuracy of electronic apex locator (EAL) measurements when using files of different sizes in roots with wide apical foramina while considering a new parameter of stability of EAL reading. Ten teeth with straight roots were subjected to a sequential widening of the apical foramen to 0.6, 0.7, and 0.8 mm. The roots were embedded after each enlargement stage in an alginate mold and subjected to EAL readings. Measurements were done using sequential K-file sizes and the self-adjusting file (SAF). Measurement stability was introduced as a new additional parameter. As the difference between the file size used and the apical diameter of the canal decreases, the results obtained were more accurate and stable. The stability and accuracy of the measurements coincided with each other in a statistically significant manner. Within the limitations of the present ex vivo study, it may be concluded that in straight canals with wide apical foramina of 0.6–0.8 mm, both SS K-files which fit snugly to the walls of apical foramen and the SAF file may offer both accurate and stable EAL measurements.
Collapse
Affiliation(s)
- Maayan Shacham
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel.
| | - Avi Levin
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel
| | - Avi Shemesh
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel
| | - Alex Lvovsky
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel
| | - Joe Ben Itzhak
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel
| | - Michael Solomonov
- Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel
| |
Collapse
|
34
|
Nguyen PN, Pham KV. Endodontic Length Measurements Using Different Modalities: An In Vitro Study. J Int Soc Prev Community Dent 2020; 10:752-758. [PMID: 33437709 PMCID: PMC7791584 DOI: 10.4103/jispcd.jispcd_357_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 08/29/2020] [Accepted: 09/18/2020] [Indexed: 01/01/2023] Open
Abstract
INTRODUCTION The aim of this study was to investigate and compare the accuracy of the 3D Endo software, conventional CBCT software Romexis Viewer, and the EAL E-Pex Pro in WL determination. MATERIALS AND METHODS Three hundred and two root canals in 110 intact human extracted molars were accessed. The actual lengths (ALs) were measured. Root canal lengths were measured using 3D Endo with proposed length (3D-PL) by software, correct length (3D-CL), Romexis Viewer, and the E-Pex Pro. The percentages of the measurements in the range of ±0.5 mm to the AL were compared using the Fisher's exact test. The paired t test and Bland-Altman plots were calculated to detect the agreement of the four methods with the AL measurements. The statistical significance was set at P<0.05. RESULTS The accuracies in the range of ±0.5 mm to the AL were 83.8%, 86.7%, 48.3%, and 99.7% for 3D-PL, 3D-CL, Romexis Viewer, and E-PexPro, respectively. There were agreements between 3D-PL and Romexis Viewer with the AL measurements. CONCLUSION The CBCT measurements using 3D Endo with the proposed length by the software and Romexis Viewer with the voxel size of 0.15 mm agreed with the AL measurements of the root canals.
Collapse
Affiliation(s)
- Phuc Ngoc Nguyen
- Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
| | - Khoa Van Pham
- Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
| |
Collapse
|
35
|
Multifrequency Impedance Method Based on Neural Network for Root Canal Length Measurement. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10217430] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Root canal therapy is the most fundamental and effective approach for treating endodontics and periapicalitis. The length of the root canal must be accurately measured to clean the pathogenic substances in it. This study aims to present a multifrequency impedance method based on a neural network for root canal length measurement. A circuit system was designed which generates a current of frequencies from 100 Hz to 20 kHz in order to augment the data of impedance ratios with different combinations of frequencies. Several impedance ratios and other quantified characteristics, such as the type of tooth and file, were selected as features to train a neural network model that could predict the distance between the file and apical foramen. The model uses leave-one-out cross-validation, adopts the Adam optimizer and regularization, and has two hidden layers with nine and five nodes, respectively. The neural network-based multifrequency impedance method exhibits nearly 95% accuracy, compared with the dual-frequency impedance ratio method (which demonstrated no more than 85% accuracy in some situations). This method may eliminate the influence of human and environmental factors on measurement of the root canal length, thereby increasing measurement robustness.
Collapse
|
36
|
Melo AM, Vivacqua-Gomes N, Bernardes RA, Vivan RR, Duarte MAH, Vasconcelos BCD. Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision. Braz Dent J 2020; 31:404-408. [PMID: 32901717 DOI: 10.1590/0103-6440202003282] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 05/04/2020] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci's type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy's, where the less conservative one produced the best results.
Collapse
Affiliation(s)
- Andrélia Maciel Melo
- School of Dentistry of Ceará, Faculdade São Leopoldo Mandic, Fortaleza, CE, Brazil
| | | | | | - Rodrigo Ricci Vivan
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, USP - Universidade de São Paulo, Bauru, SP, Brazil
| | - Marco Antônio Húngaro Duarte
- Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, USP - Universidade de São Paulo, Bauru, SP, Brazil
| | | |
Collapse
|
37
|
Klemz AA, Cruz ATG, Piasecki L, Carneiro E, Westphalen VPD, da Silva Neto UX. Accuracy of electronic apical functions of a new integrated motor compared to the visual control of the working length-an ex vivo study. Clin Oral Investig 2020; 25:231-236. [PMID: 32474809 DOI: 10.1007/s00784-020-03357-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 05/19/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate ex vivo the efficacy of the integrated motor Tri Auto ZX2 in controlling the apical extent of preparation compared to conventional visual control (CVC) of the working length (WL). MATERIALS AND METHODS Eighty standardized mandibular premolars were divided into five groups (n = 16). In the CVC group, instruments were used in continuous rotation (CR) and visual control performed by means of rubber stoppers. For each of the remaining groups, it was assigned a combination of a motion (CR or optimal torque reverse (OTR)), and an apical function (Auto Apical Reverse (AAR) or Optimum Apical Stop (OAS)). Root canals were prepared using the apical functions at 0.5 mark using an alginate model. Difference between the final WL and the actual length post-instrumentation was calculated. Data were analyzed statistically with the significance set at 5% (ANOVA, Tukey HSD). RESULTS There was no difference in the mean WL among the groups, except between the CR combined to OAS compared to CVC (P > 0.05). Although CVC resulted in two cases beyond the foramen, no significant difference was found among the groups when comparing the distributions of measurements (P > 0.05). CONCLUSIONS All combinations of motion and apical control functions of Tri Auto ZX2 provided an adequate apical limit ex vivo, similar to the visual control using rubber stoppers. CLINICAL RELEVANCE TriAuto ZX2 was efficient to control the apical extent of preparation dispensing the need for calibrating the files, regardless of the different settings. This motor might potentially prevent over-instrumentation by continuously monitoring the apical limit.
Collapse
Affiliation(s)
- Adriane Antoniw Klemz
- Department of Endodontics, School of Health and Bioscience, Pontifical Catholic University of Paraná, Curitiba, Brazil
| | - Alessandra Timponi Goes Cruz
- Department of Endodontics, School of Health and Bioscience, Pontifical Catholic University of Paraná, Curitiba, Brazil
| | - Lucila Piasecki
- Department of Periodontics & Endodontics, University at Buffalo, 240 Squire Hall, Buffalo, NY, 14214, USA.
| | - Everdan Carneiro
- Department of Endodontics, School of Health and Bioscience, Pontifical Catholic University of Paraná, Curitiba, Brazil
| | | | - Ulisses Xavier da Silva Neto
- Department of Endodontics, School of Health and Bioscience, Pontifical Catholic University of Paraná, Curitiba, Brazil
| |
Collapse
|
38
|
Cassol LG, Kowalczuck A, Carneiro E, Westphalen VPD, Laurindo CAH, da Silva Neto UX. Evaluation of fluoride and sodium hypochlorite solutions during the electrochemical dissolution of conventional NiTi instruments and Gold thermomechanically treated NiTi instruments. Int Endod J 2019; 53:513-518. [PMID: 31691303 DOI: 10.1111/iej.13244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2019] [Accepted: 11/04/2019] [Indexed: 11/30/2022]
Abstract
AIM To compare the dissolution time of two solutions, a fluoride solution and a sodium hypochlorite solution, both saturated with sodium chloride, during the electrochemical dissolution of instruments consisting of conventional nickel-titanium alloy and Gold thermomechanically treated nickel-titanium alloy. METHODOLOGY Two solutions, an NaF solution consisting of 12 g L-1 NaF with 180 g L-1 NaCl and an NaOCl solution consisting of 2.5% NaOCl with 180 g L-1 NaCl, were evaluated in a polarization test of a sample of 48 ProTaper Universal F1 (PTU F1) and WaveOne Gold Small (WOGS) instruments. The electric potentials were 0.5 V and 5 V for the NaF and NaOCl solutions, respectively. The electrochemical cell consisted of three electrodes for the polarization test of the PTU F1 and WOGS instruments, which had 6 mm of the tip immersed in the test solutions. The electric current was recorded for 540 s. If complete dissolution of the immersed tip occurred in less than the expected time, the experiment was considered complete. The time variations (in seconds) of the instruments in the solutions were measured. Data were subjected to statistical analysis using the Mann-Whitney, Kruskal-Wallis and Dunn tests. The corrosion patterns of the instruments were evaluated by scanning electron microscopy (SEM). RESULTS The NaF and NaOCl solutions were associated with significantly different (P = 0.000) dissolution times of the instrument, with mean values of 12.96 s and 83.63 s, respectively. There was no significant difference (P = 0.649) in dissolution time between the PTU F1 and WOGS instruments. CONCLUSIONS NaF and NaOCl solutions were able to electrochemically dissolve PTU F1 and WOGS instruments. However, the NaF solution achieved dissolution in significantly less time.
Collapse
Affiliation(s)
- L G Cassol
- Department of Endodontics, School of Life Sciences, Curitiba, Brazil
| | - A Kowalczuck
- Department of Endodontics, School of Life Sciences, Curitiba, Brazil
| | - E Carneiro
- Department of Endodontics, School of Life Sciences, Curitiba, Brazil
| | - V P D Westphalen
- Department of Endodontics, School of Life Sciences, Curitiba, Brazil
| | - C A H Laurindo
- Department of Mechanical Engineering, Polytechnic School, Pontifical Catholic University of Paraná, Curitiba, Brazil
| | - U X da Silva Neto
- Department of Endodontics, School of Life Sciences, Curitiba, Brazil
| |
Collapse
|
39
|
Abstract
The field of robotic surgery has progressed from small teams of researchers repurposing industrial robots, to a competitive and highly innovative subsection of the medical device industry. Surgical robots allow surgeons to perform tasks with greater ease, accuracy, or safety, and fall under one of four levels of autonomy; active, semi-active, passive, and remote manipulator. The increased accuracy afforded by surgical robots has allowed for cementless hip arthroplasty, improved postoperative alignment following knee arthroplasty, and reduced duration of intraoperative fluoroscopy among other benefits. Cutting of bone has historically used tools such as hand saws and drills, with other elaborate cutting tools now used routinely to remodel bone. Improvements in cutting accuracy and additional options for safety and monitoring during surgery give robotic surgeries some advantages over conventional techniques. This article aims to provide an overview of current robots and tools with a common target tissue of bone, proposes a new process for defining the level of autonomy for a surgical robot, and examines future directions in robotic surgery.
Collapse
|
40
|
Karuntanović T, Dačić S, Miljković N, Dačić-Simonović D. N VITROCOMPARISON OF THE ACCURACY OF TWO APEX LOCATORS OF DIFFERENT GENERATIONS. ACTA MEDICA MEDIANAE 2019. [DOI: 10.5633/amm.2019.0105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
41
|
El Hachem R, Wassef E, Mokbel N, Abboud R, Zogheib C, El Osta N, Naaman A. Influence of the Maxillary Sinus on the Accuracy of the Root ZX Apex Locator: An Ex Vivo Study. Dent J (Basel) 2019; 7:dj7010003. [PMID: 30609762 PMCID: PMC6473460 DOI: 10.3390/dj7010003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 11/15/2018] [Accepted: 12/11/2018] [Indexed: 11/30/2022] Open
Abstract
This study evaluated the accuracy of the Root ZX (J. Morita, Tokyo, Japan) electronic apex locator in determining the working length when palatal maxillary molar roots are in a relationship with the sinus. Seventeen human maxillary molars with vital pulp were scheduled for an extraction and implant placement as part of a periodontal treatment plan. The access cavity was prepared, and a #10 K file (Dentsply Maillefer, Ballaigues, Switzerland) was inserted into the palatal root using the Root ZX apex locator in order to determine the electronic working length (EWL); then, the teeth were extracted. To determine the real working length (RWL), a #10 K file was introduced into the root canal until its tip touched a glass plate. EWL and RWL were compared. Images reconstructed with CBCT (cone beam computerized tomography) revealed that eight palatal roots were related to the maxillary sinus, whereas nine were not. The results showed a significant difference between the EWL and the RWL of the palatal roots related to the sinus (p < 0.001). No significant difference was observed in measurements of roots not in contact with the sinus (p > 0.05). Within the study limitations, the reliability of Root ZX was influenced by the relationship of the roots with the maxillary sinus.
Collapse
Affiliation(s)
- Roula El Hachem
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, P.O. Box 11-5076 Riad el-Solh, Beirut 1107 2180, Lebanon.
| | - Elie Wassef
- Department of Periodontics, Faculty of Dentistry, Saint Joseph University, P.O. Box 11-5076 Riad el-Solh, Beirut 1107 2180, Lebanon.
| | - Nadim Mokbel
- Department of Periodontics, Faculty of Dentistry, Saint Joseph University, P.O. Box 11-5076 Riad el-Solh, Beirut 1107 2180, Lebanon.
| | - Richard Abboud
- Department of Maxillo-Facial Radiology, Saint Joseph University, B.P. 11-514 Riad el-Solh, Beirut 1107 2050, Lebanon.
| | - Carla Zogheib
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, P.O. Box 11-5076 Riad el-Solh, Beirut 1107 2180, Lebanon.
| | - Nada El Osta
- Department of Prosthodontics, Saint Joseph University, B.P. 11-514 Riad el-Solh, Beirut 1107 2050, Lebanon.
| | - Alfred Naaman
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, P.O. Box 11-5076 Riad el-Solh, Beirut 1107 2180, Lebanon.
| |
Collapse
|
42
|
Khatri M, Ghivari S, Pujar M, Faras R, Gopeshetti P, Vanti A. Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study. Dent Res J (Isfahan) 2019. [DOI: 10.4103/1735-3327.270779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
43
|
Piasecki L, José dos Reis P, Jussiani EI, Andrello AC. A Micro–computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars. J Endod 2018; 44:1872-1877. [DOI: 10.1016/j.joen.2018.09.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 08/28/2018] [Accepted: 09/03/2018] [Indexed: 11/28/2022]
|
44
|
Chaudhary S, Gharti A, Adhikari B. An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files. Clin Cosmet Investig Dent 2018; 10:75-82. [PMID: 29861643 PMCID: PMC5968804 DOI: 10.2147/ccide.s158882] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose A key factor affecting the success of endodontic treatment is correct determination of root canal working length (WL). The purpose of this in vivo study was to compare the accuracy of Propex II and iPex II electronic apex locator (EAL) in determining the WL under clinical conditions, to that of radiographic working length (RWL) using stainless steel (SS) and nickel–titanium (NiTi) hand files. Patients and methods Thirty-seven patients, with 60 anterior teeth (60 canals) scheduled for endodontic treatment participated in this study after ethical approval. Electronic working length (EWL) was determined by the Propex II and iPex II according to manufacturer’s instructions using SS Hand K-files and NiTi Hand files. RWL was determined after EWL determination. The results obtained with each EAL with SS and NiTi files were compared with RWL. Data was analyzed statistically at a significance level of p < 0.05. Interclass correlation coefficient was calculated. Results Statistical analysis revealed no significant difference between the EALs, indicating similar accuracies between them with respect to accuracy in determining the WL (p > 0.05). No significant difference was found between the EWL and RWL and between SS and NiTi files for WL determination (p > 0.05) as well. The result also displayed a high intraclass correlation coefficient between the RWL and EWL measurement methods. Conclusion Under the in vivo clinical conditions of this study, both Propex II and iPex II were similar to the RWL determination technique showing high correlation to RWL. Both are clinically acceptable EAL for WL determination and both SS hand K-file and NiTi file can be used interchangeably without compromising the WL during treatment.
Collapse
Affiliation(s)
- Sanjeeb Chaudhary
- Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Chitwan Medical College, Bharatpur, Nepal
| | - Archana Gharti
- Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Chitwan Medical College, Bharatpur, Nepal
| | - Bhawana Adhikari
- Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Chitwan Medical College, Bharatpur, Nepal
| |
Collapse
|
45
|
Kowollik S, Sonntag D. Accuracy and consistency of electronic root canal length determination with electrically isolating rubber stoppers. AUST ENDOD J 2018; 45:33-39. [PMID: 29573115 DOI: 10.1111/aej.12264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2018] [Indexed: 11/30/2022]
Abstract
The aim of this study was to investigate the influence of an isolating silicone stopper on the measuring accuracy and display consistency of three electrometric apex locators. The length of the canal to the major foramen was determined electrometrically using an ISO size 10 file in 20 extracted teeth each with natural crowns (Group I), amalgam fillings (Group II) or base-metal crowns (Group III), The measurements were performed with isolating or conventional silicone stoppers using three different apex locators with a four-level scale consistency rating. The use of isolating stoppers resulted in a more consistent display than with conventional stoppers, independent of the presence or type of coronal restoration (P = 0.017). Across all coronal restorations, the position of the major foramen could be determined to within ± 0.5 mm without significant differences (P = 0.79) using conventional and isolating stoppers. The use of modified isolating stoppers provides a significant increase in display consistency.
Collapse
Affiliation(s)
- Susanne Kowollik
- Department of Operative Dentistry, Periodontics and Endodontics, Düsseldorf, Germany
| | - David Sonntag
- Department of Operative Dentistry, Periodontics and Endodontics, Düsseldorf, Germany
| |
Collapse
|
46
|
Saxena D, Saha SG, Bharadwaj A, Vijaywargiya N, Dubey S, Kala S. A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An ex vivo study. J Conserv Dent 2017; 20:251-254. [PMID: 29259362 PMCID: PMC5721507 DOI: 10.4103/jcd.jcd_175_16] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Introduction: The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Propex pixi apex locator using histological sections as the gold standard. Materials and Methods: Thirty patients indicated for extraction of single-rooted permanent teeth with single canal system were selected. Working lengths (WLs) of teeth were determined using iRoot, iPex II, and Propex pixi. Teeth were then extracted, and the files were reintroduced to the anatomic apex to measure anatomic canal length (ACL) and fixed at the ACL using flowable composite. The apical 4 mm of the roots were longitudinally shaved away to visualize the canal under a stereomicroscope at ×24 magnification. Digital photographs were evaluated to measure the distance between the major diameter and minor diameter. Thus, the WL, that is, the minor diameter length (MDL) was ascertained. Results: Measurements of mean WLs within ±0.5 mm of minor diameter were 90% acceptable for iRoot, 86.66% for iPex II, and 80% for Propex pixi when compared with mean MDL as obtained from the histological sections. Conclusions: All apex locators have been shown to produce acceptable level of accuracy which clearly indicates their reliability in determining the WL.
Collapse
Affiliation(s)
- Divya Saxena
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| | - Suparna Ganguly Saha
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| | - Anuj Bharadwaj
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| | - Neelam Vijaywargiya
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| | - Sandeep Dubey
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| | - Shubham Kala
- Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India
| |
Collapse
|
47
|
Oliveira TN, Vivacqua-Gomes N, Bernardes RA, Vivan RR, Duarte MAH, Vasconcelos BC. Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols. J Endod 2017; 43:1663-1667. [DOI: 10.1016/j.joen.2017.03.039] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 03/17/2017] [Accepted: 03/22/2017] [Indexed: 11/28/2022]
|
48
|
Accuracy of 2 Endodontic Rotary Motors with Integrated Apex Locator. J Endod 2017; 43:1716-1719. [DOI: 10.1016/j.joen.2017.05.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Revised: 05/19/2017] [Accepted: 05/23/2017] [Indexed: 11/23/2022]
|
49
|
Maden M, Ertuğrul İF, Orhan EO, Erik CE, Yetiş CÇ, Tuncer Y, Kahriman M. Enhancing antibacterial effect of sodium hypochlorite by low electric current-assisted sonic agitation. PLoS One 2017; 12:e0183895. [PMID: 28854274 PMCID: PMC5576683 DOI: 10.1371/journal.pone.0183895] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 08/13/2017] [Indexed: 11/18/2022] Open
Abstract
Background This research focused on the effects of low electric current (μE)-assisted sonic agitation of sodium hypochlorite on Enterococcus faecalis infected human root dentin. Methods Extracted human canine roots were instrumented, sterilized, and experimentally contaminated with E. faecalis. After incubation for 21 days, the presence of the biofilm was confirmed by scanning electron microscopy (n = 3). Roots were randomly divided into seven groups according to decontamination procedures: G1: no treatment; G2: sterile saline; G3: 5.25% sodium hypochlorite; G4: passive ultrasonic irrigation; G5: EndoActivator (Dentsply Tulsa Dental Specialties, Tulsa, OK) agitation (EA); G6: μE agitation; and G7: μE-assisted sonic agitation. Fixed μE amperage and intensities were applied in G6 and G7. Following microbial sampling, bacterial colonies were counted using the direct plating method. Results Biofilm was not eradicated in any sample. The μE-assisted sonic agitation of sodium hypochlorite revealed the lowest cfu values (p<0.05), whereas there were no significant differences among the passive ultrasonic irrigation, EndoActivator and μE agitation alone (p>0.05). Conclusions Based on available evidence, the following conclusions were drawn: The μE-assisted sonic agitation increased the antibiofilm efficiency of sodium hypochlorite than passive ultrasonic irrigation and EndoActivator. The μE-assisted sonic agitation on 5.25% sodium hypochlorite is not capable to eradicate biofilms at 10mA energy level in 60s.
Collapse
Affiliation(s)
- Murat Maden
- Department of Endodontics, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey
| | - İhsan Furkan Ertuğrul
- Department of Endodontics Dentistry, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Ekim Onur Orhan
- Department of Endodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir, Turkey
- * E-mail:
| | - Cevat Emre Erik
- Department of Endodontics, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey
| | - Ceylan Çağıl Yetiş
- Department of Pediatric Dentistry, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey
| | - Yasin Tuncer
- Department of Food Engineering, Faculty of Engineering and Architect, Süleyman Demirel University, Isparta, Turkey
| | - Mesud Kahriman
- Department of Electronics and Communication, Faculty of Engineering & Architect, Süleyman Demirel University, Isparta, Turkey
| |
Collapse
|
50
|
Connert T, Judenhofer MS, Hülber-J M, Schell S, Mannheim JG, Pichler BJ, Löst C, ElAyouti A. Evaluation of the accuracy of nine electronic apex locators by using Micro-CT. Int Endod J 2017; 51:223-232. [DOI: 10.1111/iej.12814] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Accepted: 06/29/2017] [Indexed: 11/30/2022]
Affiliation(s)
- T. Connert
- Department of Periodontology, Endodontology and Cariology; University Centre for Dental Medicine; University of Basel; Basel Switzerland
| | - M. S. Judenhofer
- Department of Biomedical Engineering; University of California; Davis CA USA
| | - M. Hülber-J
- Division of Endodontology; Department of Conservative Dentistry; School of Dental Medicine; University of Tübingen; Tübingen Germany
| | - S. Schell
- Division of Endodontology; Department of Conservative Dentistry; School of Dental Medicine; University of Tübingen; Tübingen Germany
| | - J. G. Mannheim
- Department of Preclinical Imaging and Radiopharmacy; Werner Siemens Imaging Center; University of Tübingen; Tübingen Germany
| | - B. J. Pichler
- Department of Preclinical Imaging and Radiopharmacy; Werner Siemens Imaging Center; University of Tübingen; Tübingen Germany
| | - C. Löst
- Division of Endodontology; Department of Conservative Dentistry; School of Dental Medicine; University of Tübingen; Tübingen Germany
| | - A. ElAyouti
- Division of Endodontology; Department of Conservative Dentistry; School of Dental Medicine; University of Tübingen; Tübingen Germany
| |
Collapse
|