51
|
Chang P, Nassirpour S, Eschelbach M, Scheffler K, Henning A. Constrained optimization for position calibration of an NMR field camera. Magn Reson Med 2017; 80:380-390. [PMID: 29159823 DOI: 10.1002/mrm.27010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Revised: 10/23/2017] [Accepted: 10/25/2017] [Indexed: 11/07/2022]
Abstract
PURPOSE Knowledge of the positions of field probes in an NMR field camera is necessary for monitoring the B0 field. The typical method of estimating these positions is by switching the gradients with known strengths and calculating the positions using the phases of the FIDs. We investigated improving the accuracy of estimating the probe positions and analyzed the effect of inaccurate estimations on field monitoring. METHODS The field probe positions were estimated by 1) assuming ideal gradient fields, 2) using measured gradient fields (including nonlinearities), and 3) using measured gradient fields with relative position constraints. The fields measured with the NMR field camera were compared to fields acquired using a dual-echo gradient recalled echo B0 mapping sequence. Comparisons were done for shim fields from second- to fourth-order shim terms. RESULTS The position estimation was the most accurate when relative position constraints were used in conjunction with measured (nonlinear) gradient fields. The effect of more accurate position estimates was seen when compared to fields measured using a B0 mapping sequence (up to 10%-15% more accurate for some shim fields). The models acquired from the field camera are sensitive to noise due to the low number of spatial sample points. CONCLUSION Position estimation of field probes in an NMR camera can be improved using relative position constraints and nonlinear gradient fields. Magn Reson Med 80:380-390, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Paul Chang
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- IMPRS for Cognitive and Systems Neuroscience, Eberhard-Karls University of Tuebingen, Germany
| | - Sahar Nassirpour
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- IMPRS for Cognitive and Systems Neuroscience, Eberhard-Karls University of Tuebingen, Germany
| | - Martin Eschelbach
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- Department of Physics, Eberhard-Karls University of Tuebingen, Germany
| | - Klaus Scheffler
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard-Karls University of Tuebingen, Germany
| | - Anke Henning
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- Department of Physics, University of Greifswald, Greifswald, Germany
| |
Collapse
|
52
|
Heckova E, Považan M, Strasser B, Krumpolec P, Hnilicová P, Hangel GJ, Moser PA, Andronesi OC, van der Kouwe AJ, Valkovic P, Ukropcova B, Trattnig S, Bogner W. Real-time Correction of Motion and Imager Instability Artifacts during 3D γ-Aminobutyric Acid-edited MR Spectroscopic Imaging. Radiology 2017; 286:666-675. [PMID: 28957645 DOI: 10.1148/radiol.2017170744] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Purpose To compare the involuntary head motion, frequency and B0 shim changes, and effects on data quality during real-time-corrected three-dimensional γ-aminobutyric acid-edited magnetic resonance (MR) spectroscopic imaging in subjects with mild cognitive impairment (MCI), patients with Parkinson disease (PD), and young and older healthy volunteers. Materials and Methods In this prospective study, MR spectroscopic imaging datasets were acquired at 3 T after written informed consent was obtained. Translational and rotational head movement, frequency, and B0 shim were determined with an integrated volumetric navigator. Head motion patterns and imager instability were investigated in 33 young healthy control subjects (mean age ± standard deviation, 31 years ± 5), 34 older healthy control subjects (mean age, 67 years ± 8), 34 subjects with MCI (mean age, 72 years ± 5), and 44 patients with PD (mean age, 64 years ± 8). Spectral quality was assessed by means of region-of-interest analysis. Group differences were evaluated with Bonferroni-corrected Mann-Whitney tests. Results Three patients with PD and four subjects with MCI were excluded because of excessive head motion (ie, > 0.8 mm translation per repetition time of 1.6 seconds throughout >10 minutes). Older control subjects, patients with PD, and subjects with MCI demonstrated 1.5, 2, and 2.5 times stronger head movement, respectively, than did young control subjects (1.79 mm ± 0.77) (P < .001). Of young control subjects, older control subjects, patients with PD, and subjects with MCI, 6%, 35%, 38%, and 51%, respectively, moved more than 3 mm during the MR spectroscopic imaging acquisition of approximately 20 minutes. The predominant movements were head nodding and "sliding out" of the imager. Frequency changes were 1.1- and 1.4-fold higher in patients with PD (P = .007) and subjects with MCI (P < .001), respectively, and B0 shim changes were 1.3-, 1.5-, and 1.9-fold higher in older control subjects (P = .005), patients with PD (P < .001), and patients with MCI (P < .001), respectively, compared with those of young control subjects (12.59 Hz ± 2.49, 3.61 Hz · cm-1 ± 1.25). Real-time correction provided high spectral quality in all four groups (signal-to-noise ratio >15, Cramér-Rao lower bounds < 20%). Conclusion Real-time motion and B0 monitoring provides valuable information about motion patterns and B0 field variations in subjects with different predispositions for head movement. Immediate correction improves data quality, particularly in patients who have difficulty avoiding movement. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Eva Heckova
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Michal Považan
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Bernhard Strasser
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Patrik Krumpolec
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Petra Hnilicová
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Gilbert J Hangel
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Philipp A Moser
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Ovidiu C Andronesi
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Andre J van der Kouwe
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Peter Valkovic
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Barbara Ukropcova
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Siegfried Trattnig
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| | - Wolfgang Bogner
- From the High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (E.H., M.P., B.S., G.J.H., P.A.M., S.T., W.B.); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria (M.P., S.T., W.B.); Division of Neurosciences, Biomedical Center Martin, Jessenius Faculty of Medicine in Martin, Comenius University in Bratislava, Martin, Slovakia (P.H.); Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.C.A., A.J.v.d.K.); Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia (P.K., B.U.); and 2nd Department of Neurology (P.V.) and Institute of Pathological Physiology (B.U.), Faculty of Medicine, Comenius University in Bratislava, Bratislava, Slovakia
| |
Collapse
|
53
|
Longitudinal increases of brain metabolite levels in 5-10 year old children. PLoS One 2017; 12:e0180973. [PMID: 28700727 PMCID: PMC5507439 DOI: 10.1371/journal.pone.0180973] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 06/24/2017] [Indexed: 11/29/2022] Open
Abstract
Longitudinal magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) studies reveal significant changes in brain structure and structural networks that occur together with cognitive and behavioral maturation in childhood. However, the underlying cellular changes accompanying brain maturation are less understood. Examining regional age-related changes in metabolite levels provides insight into the physiology of neurodevelopment. Magnetic resonance spectroscopy (MRS) measures localize brain metabolism. The majority of neuroimaging studies of healthy development are from the developed world. In a longitudinal MRS study of 64 South African children aged 5 to 10 years old (29 female; 29 HIV exposed, uninfected), we examined the age-related trajectories of creatine (Cr+PCr), N-acetyl-aspartate (NAA), the combined NAA+N-acetyl-aspartyl-glutamate (NAAG), choline (GPC+PCh), glutamate (Glu) and the combined Glu+glutamine (Glu+Gln) in voxels within gray and white matter, as well as subcortically in the basal ganglia (BG). In frontal gray matter, we found age-related increases in Cr+PCr, NAA, NAA+NAAG and Glu+Gln levels pointing to synaptic activity likely related to learning. In the BG we observed increased levels of Glu, Glu+Gln and NAA+NAAG with age that point to subcortical synaptic reorganization. In white matter, we found increased levels of Cr+PCr, NAA, NAA+NAAG, Glu and Glu+Gln with age, implicating these metabolites in ongoing myelination. We observed no sex-age or HIV exposure-age interactions, indicating that physiological changes are independent of sex during this time period. The metabolite trajectories presented, therefore, provide a critical benchmark of normal cellular growth for a low socioeconomic pediatric population in the developing world against which pathology and abnormal development may be compared.
Collapse
|
54
|
Pedrosa de Barros N, Slotboom J. Quality management in in vivo proton MRS. Anal Biochem 2017; 529:98-116. [DOI: 10.1016/j.ab.2017.01.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 11/18/2016] [Accepted: 01/19/2017] [Indexed: 12/27/2022]
|
55
|
van Niekerk A, van der Kouwe A, Meintjes E. A Method for Measuring Orientation Within a Magnetic Resonance Imaging Scanner Using Gravity and the Static Magnetic Field (VectOrient). IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1129-1139. [PMID: 28129151 PMCID: PMC5637283 DOI: 10.1109/tmi.2017.2652502] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In MRI brain imaging, subject motion limits obtainable image clarity. Due to the hardware layout of an MRI scanner, gradient excitations can be used to rapidly detect position. Orientation, however, is more difficult to detect and is commonly calculated by comparing the position measurements of multiple spatially constrained points to a reference dataset. The result is increased size of the apparatus the subject must wear, which can influence the imaging workflow. In optical based methods marker attachment sites are limited due to the line of sight requirement between the camera and marker, and an external reference frame is introduced. To address these challenges a method called VectOrient is proposed for orientation measurement that is based on vector observations of gravity and the MRI scanner's static magnetic field. A prototype device comprising of an accelerometer, magnetometer and angular rate sensor shows good MRI compatibility. Phantom scans of a pineapple with zero scanner specific calibration achieve comparable results to a rigid body registration algorithm with deviations less than 0.8 degrees over 28 degree changes in orientation. Dynamic performance shows potential for prospective motion correction as rapid changes in orientation (peak 20 degrees per second) can be corrected. The pulse sequence implemented achieves orientation updates with a latency estimated to be less than 12.7 ms, of which only a small fraction (<1 ms) is used for computing orientation from the raw sensor signals. The device is capable of quantifying subject respiration and heart rates. The proposed approach for orientation estimation could help address some limitations of existing methods such as orientation measurement range, temporal resolution, ease of use and marker placement.
Collapse
|
56
|
Ip IB, Berrington A, Hess AT, Parker AJ, Emir UE, Bridge H. Combined fMRI-MRS acquires simultaneous glutamate and BOLD-fMRI signals in the human brain. Neuroimage 2017; 155:113-119. [PMID: 28433623 PMCID: PMC5519502 DOI: 10.1016/j.neuroimage.2017.04.030] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 04/12/2017] [Accepted: 04/13/2017] [Indexed: 01/29/2023] Open
Abstract
Combined fMRI-MRS is a novel method to non-invasively investigate functional activation in the human brain using simultaneous acquisition of hemodynamic and neurochemical measures. The aim of the current study was to quantify neural activity using combined fMRI-MRS at 7 T. BOLD-fMRI and semi-LASER localization MRS data were acquired from the visual cortex of 13 participants during short blocks (64 s) of flickering checkerboards. We demonstrate a correlation between glutamate and BOLD-fMRI time courses (R=0.381, p=0.031). In addition, we show increases in BOLD-fMRI (1.43±0.17%) and glutamate concentrations (0.15±0.05 I.U., ~2%) during visual stimulation. In contrast, we observed no change in glutamate concentrations in resting state MRS data during sham stimulation periods. Spectral line width changes generated by the BOLD-response were corrected using line broadening. In summary, our results establish the feasibility of concurrent measurements of BOLD-fMRI and neurochemicals using a novel combined fMRI-MRS sequence. Our findings strengthen the link between glutamate and functional activity in the human brain by demonstrating a significant correlation of BOLD-fMRI and glutamate over time, and by showing ~2% glutamate increases during 64 s of visual stimulation. Our tool may become useful for studies characterizing functional dynamics between neurochemicals and hemodynamics in health and disease. Novel MRI sequence measures hemodynamics and neurochemistry in same TR. Stimulation block duration relevant for functional experiments (64s). BOLD-fMRI and glutamate time courses correlate during functional stimulation. Visual stimulation increases glutamate concentrations. Useful to study fundamental relationship between hemodynamics and neurochemistry.
Collapse
Affiliation(s)
- I Betina Ip
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxfordshire OX1 3PT, UK; Oxford Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Oxford, Oxfordshire OX3 9DU, UK.
| | - Adam Berrington
- Oxford Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Oxford, Oxfordshire OX3 9DU, UK
| | - Aaron T Hess
- Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, Oxfordshire OX3 9DU, UK
| | - Andrew J Parker
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxfordshire OX1 3PT, UK
| | - Uzay E Emir
- Oxford Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Oxford, Oxfordshire OX3 9DU, UK
| | - Holly Bridge
- Oxford Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Oxford, Oxfordshire OX3 9DU, UK
| |
Collapse
|
57
|
Zhang Y, Aganj I, van der Kouwe AJW, Tisdall MD. Effects of Resolution and Registration Algorithm on the Accuracy of EPI vNavs for Real Time Head Motion Correction in MRI. CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS. IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION. WORKSHOPS 2017; 2016:583-591. [PMID: 28396821 DOI: 10.1109/cvprw.2016.79] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Low-resolution, EPI-based Volumetric Navigators (vNavs) have been used as a prospective motion-correction system in a variety of MRI neuroimaging pulse sequences. The use of low-resolution volumes represents a trade-off between motion tracking accuracy and acquisition time. However, this means that registration must be accurate on the order of 0.2 voxels or less to be effective for motion correction. While vNavs have shown promising results in clinical and research use, the choice of navigator and registration algorithm have not previously been systematically evaluated. In this work we experimentally evaluate the accuracy of vNavs, and possible design choices for future improvements to the system, using real human data. We acquired navigator volumes at three isotropic resolutions (6.4 mm, 8 mm, and 10 mm) with known rotations and translations. The vNavs were then rigidly registered using trilinear, tricubic, and cubic B-spline interpolation. We demonstrate a novel refactoring of the cubic B-spline algorithm that stores pre-computed coefficients to reduce the per-interpolation time to be identical to tricubic interpolation. Our results show that increasing vNav resolution improves registration accuracy, and that cubic B-splines provide the highest registration accuracy at all vNav resolutions. Our results also suggest that the time required by vNavs may be reduced by imaging at 10 mm resolution, without substantial cost in registration accuracy.
Collapse
Affiliation(s)
- Yingzhuo Zhang
- Institute for Applied Computational Science and Engineering, Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, Massachusetts, USA
| | - Iman Aganj
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA, Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - André J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA, Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - M Dylan Tisdall
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA, Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
58
|
Zhang Y, Aganj I, van der Kouwe AJW, Tisdall MD. Accurate High-speed 3D-Registration of EPI vNavs for Head Motion Correction. PROCEEDINGS OF THE INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE ... SCIENTIFIC MEETING AND EXHIBITION. INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE. SCIENTIFIC MEETING AND EXHIBITION 2017; 25:3944. [PMID: 29643747 PMCID: PMC5891164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Low-resolution, whole-head volumes can be acquired rapidly with EPI-based volumetric navigators (vNavs). vNavs interspersed in a longer scan are widely used for prospective motion correction in a variety of sequences. To further improve the accuracy and flexibility of vNavs, we present a novel registration algorithm, tailored specifically for the vNavs application. Accuracy of the algorithm is tested on navigator volumes acquired with human volunteers at three isotropic resolutions, 6.4mm, 8mm, and 10mm, using a series of field of view (FOV) rotations and translations to provide ground truth rigid "motion".
Collapse
Affiliation(s)
- Yingzhuo Zhang
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, United States
| | - Iman Aganj
- Athinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital, Charlestown, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - André J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital, Charlestown, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Matthew Dylan Tisdall
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
| |
Collapse
|
59
|
Joers JM, Deelchand DK, Kumar A, Moheet A, Seaquist E, Henry PG, Öz G. Measurement of Hypothalamic Glucose Under Euglycemia and Hyperglycemia by MRI at 3T. J Magn Reson Imaging 2017; 45:681-691. [PMID: 27402249 PMCID: PMC5575789 DOI: 10.1002/jmri.25383] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Accepted: 06/21/2016] [Indexed: 12/26/2022] Open
Abstract
PURPOSE To evaluate the feasibility of using a clinical magnetic resonance (MR) system and MR spectroscopy (MRS) to measure glucose concentration changes in the human hypothalamus, a structure central to whole-body glucose regulation. SUBJECTS AND METHODS A time series of MR spectra (semi-LASER, TE = 28 msec), localized to the bilateral hypothalamus (∼1.6 ml) were obtained at 3T in six healthy subjects at baseline (euglycemia) and during a ∼65-70-minute-long hyperglycemic clamp in 11-minute blocks with interleaved T1 FLASH images to retrospectively assess head motion, and track changes in cerebrospinal fluid (CSF) partial volume. The LCModel was used to quantify the sum of glucose and taurine concentrations, [Glc+Tau], along with their associated Cramér-Rao lower bounds (CRLB). RESULTS Spectral quality allowed quantification of [Glc+Tau] (sum reported due to high negative correlation between these metabolites) with CRLB <25% in 35/36 timepoints during hyperglycemia. Increased [Glc+Tau] was observed with hyperglycemia in all subjects, but most reliably in those with plasma glucose targets ≥300 mg/dl. For these subjects, [Glc+Tau]baseline (n = 4) was 1.5 (±0.3, SD) mM, and increased to 4.5 (±1.1) mM (n = 16) for timepoints acquired ≥25 minutes after onset of the clamp, with 15/16 timepoints having no overlap of 95% confidence intervals (CIs) between baseline and hyperglycemia. Preliminary analysis revealed a linear (1:5) relationship between hypothalamus-blood glucose concentrations. CONCLUSION It is feasible to measure glucose concentration changes in the human hypothalamus using a standard 3T scanner and a short-echo semi-LASER sequence by utilizing retrospective motion tracking, CSF correction, predetermined quality acceptance criteria, and hyperglycemic blood glucose levels ≥300 mg/dl. LEVEL OF EVIDENCE 2 J. Magn. Reson. Imaging 2017;45:681-691.
Collapse
Affiliation(s)
- James M. Joers
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Dinesh K. Deelchand
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Anjali Kumar
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, University of Minnesota, Minneapolis, Minnesota, USA
| | - Amir Moheet
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, University of Minnesota, Minneapolis, Minnesota, USA
| | - Elizabeth Seaquist
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, University of Minnesota, Minneapolis, Minnesota, USA
| | - Pierre-Gilles Henry
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Gülin Öz
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
60
|
Njau S, Joshi SH, Espinoza R, Leaver AM, Vasavada M, Marquina A, Woods RP, Narr KL. Neurochemical correlates of rapid treatment response to electroconvulsive therapy in patients with major depression. J Psychiatry Neurosci 2017; 42:6-16. [PMID: 27327561 PMCID: PMC5373714 DOI: 10.1503/jpn.150177] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Electroconvulsive therapy (ECT) is a highly effective brain stimulation treatment for severe depression. Identifying neurochemical changes linked with ECT may point to biomarkers and predictors of successful treatment response. METHODS We used proton magnetic resonance spectroscopy (1H-MRS) to measure longitudinal changes in glutamate/glutamine (Glx), creatine (Cre), choline (Cho) and N-acetylaspartate (NAA) in the dorsal (dACC) and subgenual anterior cingulate cortex (sgACC) and bilateral hippocampus in patients receiving ECT scanned at baseline, after the second ECT session and after the ECT treatment series. Patients were compared with demographically similar controls at baseline. Controls were assessed twice to establish normative values and variance. RESULTS We included 50 patients (mean age 43.78 ± 14 yr) and 33 controls (mean age 39.33 ± 12 yr) in our study. Patients underwent a mean of 9 ± 4.1 sessions of ECT. At baseline, patients showed reduced Glx in the sgACC, reduced NAA in the left hippocampus and increased Glx in the left hippocampus relative to controls. ECT was associated with significant increases in Cre in the dACC and sgACC and decreases in NAA in the dACC and right hippocampus. Lower NAA levels in the dACC at baseline predicted reductions in depressive symptoms. Both ECT and symptom improvement were associated with decreased Glx in the left hippocampus and increased Glx in the sgACC. LIMITATIONS Attrition and clinical heterogeneity may have masked more subtle findings. CONCLUSION ECT elicits robust effects on brain chemistry, impacting Cre, NAA and Glx, which suggests restorative and neurotrophic processes. Differential effects of Glx in the sgACC and hippocampus, which approach control values with treatment, may reflect previously implicated underactive cortical and overactive subcortical limbic circuitry in patients with major depression. NAA levels at baseline are predictive of therapeutic outcome and could inform future treatment strategies.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Katherine L. Narr
- Correspondence to: K. Narr, 635 Charles E Young Dr S #225, University of California Los Angeles, Los Angeles CA 90095;
| |
Collapse
|
61
|
Rapalino O, Ratai EM. Multiparametric Imaging Analysis: Magnetic Resonance Spectroscopy. Magn Reson Imaging Clin N Am 2016; 24:671-686. [PMID: 27742109 DOI: 10.1016/j.mric.2016.06.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Magnetic resonance spectroscopy (MRS) is a magnetic resonance-based imaging modality that allows noninvasive sampling of metabolic changes in normal and abnormal brain parenchyma. MRS is particularly useful in the differentiation of developmental or non-neoplastic disorders from neoplastic processes. MRS is also useful during routine imaging follow-up after radiation treatment or during antiangiogenic treatment and for predicting outcomes and treatment response. The objective of this article is to provide a concise but thorough review of the basic physical principles, important applications of MRS in brain tumor imaging, and future directions.
Collapse
Affiliation(s)
- O Rapalino
- Neuroradiology Division, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
| | - E M Ratai
- Neuroradiology Division, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA; MGH/HST Athinoula A. Martinos Center for Biomedical Imaging, Building 149, 13th Street, Room 2301, Charlestown, MA 02129, USA.
| |
Collapse
|
62
|
Variations in myo-inositol in fronto-limbic regions and clinical response to electroconvulsive therapy in major depression. J Psychiatr Res 2016; 80:45-51. [PMID: 27285661 PMCID: PMC4980182 DOI: 10.1016/j.jpsychires.2016.05.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 05/03/2016] [Accepted: 05/26/2016] [Indexed: 11/22/2022]
Abstract
Though electroconvulsive therapy (ECT) is an established treatment for severe depression, the neurobiological factors accounting for the clinical effects of ECT are largely unknown. Myo-inositol, a neurometabolite linked with glial activity, is reported as reduced in fronto-limbic regions in patients with depression. Whether changes in myo-inositol relate to the antidepressant effects of ECT is unknown. Using magnetic resonance spectroscopy ((1)H-MRS), we measured dorsomedial anterior cingulate cortex (dmACC) and left and right hippocampal myo-inositol in 50 ECT patients (mean age: 43.78, 14 SD) and 33 controls (mean age: 39.33, 12 SD) to determine cross sectional effects of diagnosis and longitudinal effects of ECT. Patients were scanned prior to treatment, after the second ECT and at completion of the ECT index series. Controls were scanned twice at intervals corresponding to patients' baseline and end of treatment scans. Myo-inositol increased over the course of ECT in the dmACC (p = 0.042). A significant hemisphere by clinical response effect was observed for the hippocampus (p = 0.003) where decreased myo-inositol related to symptom improvement in the left hippocampus. Cross-sectional differences between patients and controls at baseline were not detected. Changes in myo-inositol observed in the dmACC in association with ECT and in the hippocampus in association with ECT-related clinical response suggest the mechanisms of ECT could include gliogenesis or a reversal of gliosis that differentially affect dorsal and ventral limbic regions. Change in dmACC myo-inositol diverged from control values with ECT suggesting compensation, while hippocampal change suggested normalization.
Collapse
|
63
|
Inherited or acquired metabolic disorders. HANDBOOK OF CLINICAL NEUROLOGY 2016. [PMID: 27432685 DOI: 10.1016/b978-0-444-53485-9.00029-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2023]
Abstract
This chapter starts with a description of imaging of inherited metabolic disorders, followed by a discussion on imaging of acquired toxic-metabolic disorders of the adult brain. Neuroimaging is crucial for the diagnosis and management of a number of inherited metabolic disorders. Among these, inherited white-matter disorders commonly affect both the nervous system and endocrine organs. Magnetic resonance imaging (MRI) has enabled new classifications of these disorders that have greatly enhanced both our diagnostic ability and our understanding of these complex disorders. Beyond the classic leukodystrophies, we are increasingly recognizing new hereditary leukoencephalopathies such as the hypomyelinating disorders. Conventional imaging can be unrevealing in some metabolic disorders, but proton magnetic resonance spectroscopy (MRS) may be able to directly visualize the metabolic abnormality in certain disorders. Hence, neuroimaging can enhance our understanding of pathogenesis, even in the absence of a pathologic specimen. This review aims to present pathognomonic brain MRI lesion patterns, the diagnostic capacity of proton MRS, and information from clinical and laboratory testing that can aid diagnosis. We demonstrate that applying an advanced neuroimaging approach enhances current diagnostics and management. Additional information on inherited and metabolic disorders of the brain can be found in Chapter 63 in the second volume of this series.
Collapse
|
64
|
Juchem C, de Graaf RA. B 0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy. Anal Biochem 2016; 529:17-29. [PMID: 27293215 DOI: 10.1016/j.ab.2016.06.003] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 05/26/2016] [Accepted: 06/01/2016] [Indexed: 10/21/2022]
Abstract
The homogenization of B0 conditions is necessary for every magnetic resonance spectroscopy (MRS) investigation. Its direct consequence is narrow spectral lines, on which reliable separation and quantification of biochemicals, and thus experimentally obtainable metabolic information, fundamentally relies. Besides spectral linewidth, unwanted B0 inhomogeneity also impairs other aspects of the MRS experiment, such as water suppression and editing efficiency, that rely on exact frequency definition. Therefore, experimental B0 homogenization, called B0 shimming, is mandatory for meaningful MRS, and high-level B0 shimming is arguably one of the most important ingredients for successful MRS investigations. In this review, we describe the relevance of B0 homogeneity for in vivo MRS and summarize common concepts and specific solutions for its experimental optimization.
Collapse
Affiliation(s)
- Christoph Juchem
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT 06520, USA; Department of Neurology, Yale University School of Medicine, New Haven, CT 06520, USA.
| | - Robin A de Graaf
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT 06520, USA; Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| |
Collapse
|
65
|
HIV-associated CD4+/CD8+ depletion in infancy is associated with neurometabolic reductions in the basal ganglia at age 5 years despite early antiretroviral therapy. AIDS 2016; 30:1353-62. [PMID: 26959509 DOI: 10.1097/qad.0000000000001082] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Investigating consequences of early or late antiretroviral therapy (ART) initiation in infancy on young brain development using magnetic resonance spectroscopy. DESIGN Most pediatric HIV/ART-related neurological studies are from neuropsychological/clinical perspectives. Magnetic resonance spectroscopy can elucidate the mechanisms underpinning neurocognitive outcomes by quantifying the brain's chemical condition through localized metabolism to provide insights into health and development. METHODS Basal ganglia metabolite concentrations were assessed in thirty-eight 5-year-old HIV-infected children previously participating in a randomized trial comparing early limited ART to deferred continuous ART, as well as 15 uninfected controls (12 HIV exposed). Metabolite levels were compared between 26 infected children who initiated ART at/before 12 weeks and 12 who initiated afterward, and were correlated with clinical HIV and treatment-related measures. RESULTS HIV-infected children initiating ART after 12 weeks had lower creatine, choline and glutamate (P < 0.05) than those initiating ART at/before 12 weeks. The CD4/CD8 ratio at baseline correlated with N-acetyl-aspartate (r = 0.56, P = 0.003) and choline (r = 0.36, P = 0.03) at 5 years, irrespective of treatment regimen and ART interruption. In comparison with uninfected controls, 80% of whom were HIV-exposed in utero, children on early treatment had higher N-acetyl-aspartate (P = 0.006) and choline (P = 0.03). CONCLUSIONS Despite early ART (<12 weeks), low baseline CD4/CD8 predicts brain metabolite levels in later childhood. Also, HIV exposure and antiretroviral exposure for preventing vertical HIV transmission may hinder metabolite health, but needs further investigation.
Collapse
|
66
|
Saleh MG, Alhamud A, Near J, van der Kouwe AJW, Meintjes EM. Volumetric navigated MEGA-SPECIAL for real-time motion and shim corrected GABA editing. NMR IN BIOMEDICINE 2016; 29:248-55. [PMID: 26663075 DOI: 10.1002/nbm.3454] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 11/04/2015] [Accepted: 11/09/2015] [Indexed: 05/28/2023]
Abstract
Mescher-Garwood (MEGA) editing with spin echo full intensity acquired localization (MEGA-SPECIAL, MSpc) is a technique to acquire γ-aminobutyric acid (GABA) without macromolecule (MM) contamination at a TE of 68 ms. However, due to the requirement of multiple shot-localization, it is often susceptible to subject motion and B0 inhomogeneity. A method is presented for real-time shim and motion correction (ShMoCo) using volumetric navigators to correct for motion and motion-related B0 inhomogeneity during MSpc acquisition. A phantom experiment demonstrates that ShMoCo restores the GABA peak and improves spectral quality in the presence of motion and zero- and first-order shim changes. The ShMoCo scans were validated in three subjects who performed up-down and left-right head rotations. Qualitative assessment of these scans indicates effective reduction of subtraction artefacts and well edited GABA peaks, while quantitative analysis indicates superior fitting and spectral quality relative to scans with no correction. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Muhammad G Saleh
- Department of Human Biology, MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town, Western Cape, South Africa
| | - A Alhamud
- Department of Human Biology, MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town, Western Cape, South Africa
| | - Jamie Near
- Douglas Mental Health University Institute and Department of Psychiatry, McGill University, Montreal, Canada
| | - André J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States
| | - Ernesta M Meintjes
- Department of Human Biology, MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town, Western Cape, South Africa
| |
Collapse
|
67
|
Godenschweger F, Kägebein U, Stucht D, Yarach U, Sciarra A, Yakupov R, Lüsebrink F, Schulze P, Speck O. Motion correction in MRI of the brain. Phys Med Biol 2016; 61:R32-56. [PMID: 26864183 DOI: 10.1088/0031-9155/61/5/r32] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed.
Collapse
Affiliation(s)
- F Godenschweger
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
68
|
Yarach U, Luengviriya C, Stucht D, Godenschweger F, Schulze P, Speck O. Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:319-32. [PMID: 26861047 DOI: 10.1007/s10334-015-0515-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 11/20/2015] [Accepted: 11/21/2015] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Prospective motion correction can effectively fix the imaging volume of interest. For large motion, this can lead to relative motion of coil sensitivities, distortions associated with imaging gradients and B 0 field variations. This work accounts for the B 0 field change due to subject movement, and proposes a method for correcting tissue magnetic susceptibility-related distortion in prospective motion correction. MATERIALS AND METHODS The B 0 field shifts at the different head orientations were characterized. A volunteer performed large motion with prospective motion correction enabled. The acquired data were divided into multiple groups according to the object positions. The correction of B 0-related distortion was applied to each group of data individually via augmented sensitivity encoding with additionally integrated gradient nonlinearity correction. RESULTS The relative motion of the gradients, B 0 field and coil sensitivities in prospective motion correction results in residual spatial distortion, blurring, and coil artifacts. These errors can be mitigated by the proposed method. Moreover, iterative conjugate gradient optimization with regularization provided superior results with smaller RMSE in comparison to standard conjugate gradient. CONCLUSION The combined correction of B 0-related distortion and gradient nonlinearity leads to a reduction of residual motion artifacts in prospective motion correction data.
Collapse
Affiliation(s)
- Uten Yarach
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Leipziger Str. 44 (Haus 65), 39120, Magdeburg, Germany. .,Department of Radiological Technology, Chiangmai University, Chiang Mai, Thailand.
| | | | - Daniel Stucht
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Leipziger Str. 44 (Haus 65), 39120, Magdeburg, Germany
| | - Frank Godenschweger
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Leipziger Str. 44 (Haus 65), 39120, Magdeburg, Germany
| | - Peter Schulze
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Leipziger Str. 44 (Haus 65), 39120, Magdeburg, Germany.,German Centre for Neurodegenerative Diseases (DZNE), Site Magdeburg, Magdeburg, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Leipziger Str. 44 (Haus 65), 39120, Magdeburg, Germany.,Leibniz Institute for Neurobiology, Magdeburg, Germany.,German Centre for Neurodegenerative Diseases (DZNE), Site Magdeburg, Magdeburg, Germany.,Center for Behavioral Brain Sciences, Magdeburg, Germany
| |
Collapse
|
69
|
Ratai EM, Gilberto González R. Clinical magnetic resonance spectroscopy of the central nervous system. HANDBOOK OF CLINICAL NEUROLOGY 2016; 135:93-116. [PMID: 27432661 DOI: 10.1016/b978-0-444-53485-9.00005-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Proton magnetic resonance spectroscopy (1H MRS) is a noninvasive imaging technique that can easily be added to the conventional magnetic resonance (MR) imaging sequences. Using MRS one can directly compare spectra from pathologic or abnormal tissue and normal tissue. Metabolic changes arising from pathology that can be visualized by MRS may not be apparent from anatomy that can be visualized by conventional MR imaging. In addition, metabolic changes may precede anatomic changes. Thus, MRS is used for diagnostics, to observe disease progression, monitor therapeutic treatments, and to understand the pathogenesis of diseases. MRS may have an important impact on patient management. The purpose of this chapter is to provide practical guidance in the clinical application of MRS of the brain. This chapter provides an overview of MRS-detectable metabolites and their significance. In addition some specific current clinical applications of MRS will be discussed, including brain tumors, inborn errors of metabolism, leukodystrophies, ischemia, epilepsy, and neurodegenerative diseases. The chapter concludes with technical considerations and challenges of clinical MRS.
Collapse
Affiliation(s)
- Eva-Maria Ratai
- Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, and Athinoula A. Martinos Center for Biomedical Imaging, Boston, MA, USA.
| | - R Gilberto González
- Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, and Athinoula A. Martinos Center for Biomedical Imaging, Boston, MA, USA
| |
Collapse
|
70
|
Tisdall MD, Reuter M, Qureshi A, Buckner RL, Fischl B, van der Kouwe AJW. Prospective motion correction with volumetric navigators (vNavs) reduces the bias and variance in brain morphometry induced by subject motion. Neuroimage 2015; 127:11-22. [PMID: 26654788 DOI: 10.1016/j.neuroimage.2015.11.054] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Revised: 11/20/2015] [Accepted: 11/21/2015] [Indexed: 10/22/2022] Open
Abstract
Recent work has demonstrated that subject motion produces systematic biases in the metrics computed by widely used morphometry software packages, even when the motion is too small to produce noticeable image artifacts. In the common situation where the control population exhibits different behaviors in the scanner when compared to the experimental population, these systematic measurement biases may produce significant confounds for between-group analyses, leading to erroneous conclusions about group differences. While previous work has shown that prospective motion correction can improve perceived image quality, here we demonstrate that, in healthy subjects performing a variety of directed motions, the use of the volumetric navigator (vNav) prospective motion correction system significantly reduces the motion-induced bias and variance in morphometry.
Collapse
Affiliation(s)
- M Dylan Tisdall
- Athinoula A. Martinos Center for Biomedical Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA; Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| | - Martin Reuter
- Athinoula A. Martinos Center for Biomedical Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA; Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA; Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Abid Qureshi
- Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| | - Randy L Buckner
- Athinoula A. Martinos Center for Biomedical Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA; Center for Brain Science, Harvard University, Cambridge, MA 02138, USA; Department of Psychology, Harvard University, Cambridge, MA 02138, USA; Department of Psychiatry, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| | - Bruce Fischl
- Athinoula A. Martinos Center for Biomedical Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA; Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA; Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - André J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA; Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
71
|
Frost R, Hess AT, Okell TW, Chappell MA, Tisdall MD, van der Kouwe AJW, Jezzard P. Prospective motion correction and selective reacquisition using volumetric navigators for vessel-encoded arterial spin labeling dynamic angiography. Magn Reson Med 2015; 76:1420-1430. [PMID: 26567122 DOI: 10.1002/mrm.26040] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 10/14/2015] [Accepted: 10/17/2015] [Indexed: 11/06/2022]
Abstract
PURPOSE The aim of this study was to improve robustness to motion in a vessel-encoded angiography sequence used for patient scans. The sequence is particularly sensitive to motion between imaging segments, which causes ghosting and blurring that propagates to the final angiogram. METHODS Volumetric echo planar imaging (EPI) navigators acquired in 275 ms were inserted after the imaging readout in a vessel-encoded pseudo-continuous arterial spin labeling (VEPCASL) sequence. The effects of movement between segments on the images were tested with phantom experiments. Deliberate motion experiments with healthy volunteers were performed to compare prospective motion correction (PMC) with reacquisition versus no correction. RESULTS In scans without motion, the addition of the EPI navigator to the sequence did not affect the quality of the angiograms in comparison with the original sequence. PMC and reacquisition improved the visibility of vessels in the angiograms compared with the scans without correction. The reacquisition strategy was shown to be important for complete correction of imaging artifacts. CONCLUSION We have demonstrated an effective method to correct motion in vessel-encoded angiography. For reacquisition of 15 segments, the technique requires approximately 30 s of additional scanning (∼25%). Magn Reson Med 76:1420-1430, 2016. © 2015 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Robert Frost
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
| | - Aaron T Hess
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Thomas W Okell
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Michael A Chappell
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.,Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - M Dylan Tisdall
- A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - André J W van der Kouwe
- A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Peter Jezzard
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
72
|
Alhamud A, Taylor PA, van der Kouwe AJW, Meintjes EM. Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence. Neuroimage 2015; 126:60-71. [PMID: 26584865 DOI: 10.1016/j.neuroimage.2015.11.022] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 09/18/2015] [Accepted: 11/09/2015] [Indexed: 11/19/2022] Open
Abstract
Diffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates. In this work we introduce a novel technique to simultaneously measure, report and correct in real time subject motion and changes in B0 field homogeneity, both in and through the imaging plane. This is achieved using double volumetric navigators (DvNav), i.e. a pair of 3D EPI acquisitions, interleaved with the DTI pulse sequence. Changes in the B0 field are evaluated in terms of zero-order (frequency) and first-order (linear gradients) shim. The ability of the DvNav to accurately estimate the shim parameters was first validated in a water phantom. Two healthy subjects were scanned both in the presence and absence of motion using standard, motion corrected (single navigator, vNav), and DvNav DTI sequences. The difference in performance between the proposed 3D EPI field maps and the standard 3D gradient echo field maps of the MRI scanner was also evaluated in a phantom and two healthy subjects. The DvNav sequence was shown to accurately measure and correct changes in B0 following manual adjustments of the scanner's central frequency and the linear shim gradients. Compared to other methods, the DvNav produced DTI results that showed greater spatial overlap with anatomical references, particularly in scans with subject motion. This is largely due to the ability of the DvNav system to correct shim changes and subject motion between each volume acquisition, thus reducing shear distortion.
Collapse
Affiliation(s)
- A Alhamud
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa.
| | - Paul A Taylor
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa; African Institute for Mathematical Sciences (AIMS), South Africa
| | - Andre J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Brookline, MA, USA
| | - Ernesta M Meintjes
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa
| |
Collapse
|
73
|
Babayeva M, Kober T, Knowles B, Herbst M, Meuli R, Zaitsev M, Krueger G. Accuracy and Precision of Head Motion Information in Multi-Channel Free Induction Decay Navigators for Magnetic Resonance Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:1879-1889. [PMID: 25781624 DOI: 10.1109/tmi.2015.2413211] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13°, respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1° for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.
Collapse
|
74
|
Engström M, Mårtensson M, Avventi E, Norbeck O, Skare S. Collapsed fat navigators for brain 3D rigid body motion. Magn Reson Imaging 2015; 33:984-91. [PMID: 26117701 DOI: 10.1016/j.mri.2015.06.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2015] [Revised: 05/25/2015] [Accepted: 06/20/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE To acquire high-resolution 3D multi-slab echo planar imaging data without motion artifacts, using collapsed fat navigators. METHODS A fat navigator module (collapsed FatNav) was added to a diffusion-weighted 3D multi-slab echo planar imaging (DW 3D-MS EPI) sequence, comprising three orthogonal echo planar imaging readouts to track rigid body head motion in the image domain and performing prospective motion correction. The stability, resolution and accuracy of the navigator were investigated on phantoms and healthy volunteers. RESULTS The experiments on phantoms and volunteers show that the navigator, depicting projections of the subcutaneous fat in of the head, is capable of correcting for head motion with insignificant bias compared to motion estimates derived from the water-signaling DWI images. Despite that this projection technique implies a non-sparse image appearance, collapsed FatNav data could be highly accelerated with parallel imaging, allowing three orthogonal 2D EPI readouts in about 6ms. CONCLUSION By utilizing signal from the leading fat saturation RF pulse of the diffusion sequence, only the readout portion of the navigator needs to be added, resulting in a scan time penalty of only about 5%. Motion can be detected and corrected for with a 5-10Hz update frequency when combined with a sequence like the DW 3D-MS EPI.
Collapse
Affiliation(s)
- Mathias Engström
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden; EMEA Research and Collaboration, GE Applies Science Laboratory, GE Healthcare, Stockholm, Sweden.
| | - Magnus Mårtensson
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden; EMEA Research and Collaboration, GE Applies Science Laboratory, GE Healthcare, Stockholm, Sweden
| | - Enrico Avventi
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden; EMEA Research and Collaboration, GE Applies Science Laboratory, GE Healthcare, Stockholm, Sweden
| | - Ola Norbeck
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden; EMEA Research and Collaboration, GE Applies Science Laboratory, GE Healthcare, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden; EMEA Research and Collaboration, GE Applies Science Laboratory, GE Healthcare, Stockholm, Sweden
| |
Collapse
|
75
|
Zaitsev M, Maclaren J, Herbst M. Motion artifacts in MRI: A complex problem with many partial solutions. J Magn Reson Imaging 2015; 42:887-901. [PMID: 25630632 DOI: 10.1002/jmri.24850] [Citation(s) in RCA: 348] [Impact Index Per Article: 38.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Accepted: 12/22/2014] [Indexed: 01/29/2023] Open
Abstract
Subject motion during magnetic resonance imaging (MRI) has been problematic since its introduction as a clinical imaging modality. While sensitivity to particle motion or blood flow can be used to provide useful image contrast, bulk motion presents a considerable problem in the majority of clinical applications. It is one of the most frequent sources of artifacts. Over 30 years of research have produced numerous methods to mitigate or correct for motion artifacts, but no single method can be applied in all imaging situations. Instead, a "toolbox" of methods exists, where each tool is suitable for some tasks, but not for others. This article reviews the origins of motion artifacts and presents current mitigation and correction methods. In some imaging situations, the currently available motion correction tools are highly effective; in other cases, appropriate tools still need to be developed. It seems likely that this multifaceted approach will be what eventually solves the motion sensitivity problem in MRI, rather than a single solution that is effective in all situations. This review places a strong emphasis on explaining the physics behind the occurrence of such artifacts, with the aim of aiding artifact detection and mitigation in particular clinical situations.
Collapse
Affiliation(s)
- Maxim Zaitsev
- Department of Radiology, University Medical Centre Freiburg, Freiburg, Germany
| | - Julian Maclaren
- Department of Radiology, University Medical Centre Freiburg, Freiburg, Germany.,Department of Radiology, Stanford University, Stanford, California, USA
| | - Michael Herbst
- Department of Radiology, University Medical Centre Freiburg, Freiburg, Germany.,University of Hawaii, Department of Medicine, John A. Burns School of Medicine, Honolulu, Hawaii, USA
| |
Collapse
|
76
|
Bogner W, Gagoski B, Hess AT, Bhat H, Tisdall MD, van der Kouwe AJW, Strasser B, Marjańska M, Trattnig S, Grant E, Rosen B, Andronesi OC. 3D GABA imaging with real-time motion correction, shim update and reacquisition of adiabatic spiral MRSI. Neuroimage 2014; 103:290-302. [PMID: 25255945 PMCID: PMC4312209 DOI: 10.1016/j.neuroimage.2014.09.032] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 09/04/2014] [Accepted: 09/15/2014] [Indexed: 12/12/2022] Open
Abstract
Gamma-aminobutyric acid (GABA) and glutamate (Glu) are the major neurotransmitters in the brain. They are crucial for the functioning of healthy brain and their alteration is a major mechanism in the pathophysiology of many neuro-psychiatric disorders. Magnetic resonance spectroscopy (MRS) is the only way to measure GABA and Glu non-invasively in vivo. GABA detection is particularly challenging and requires special MRS techniques. The most popular is MEscher-GArwood (MEGA) difference editing with single-voxel Point RESolved Spectroscopy (PRESS) localization. This technique has three major limitations: a) MEGA editing is a subtraction technique, hence is very sensitive to scanner instabilities and motion artifacts. b) PRESS is prone to localization errors at high fields (≥3T) that compromise accurate quantification. c) Single-voxel spectroscopy can (similar to a biopsy) only probe steady GABA and Glu levels in a single location at a time. To mitigate these problems, we implemented a 3D MEGA-editing MRS imaging sequence with the following three features: a) Real-time motion correction, dynamic shim updates, and selective reacquisition to eliminate subtraction artifacts due to scanner instabilities and subject motion. b) Localization by Adiabatic SElective Refocusing (LASER) to improve the localization accuracy and signal-to-noise ratio. c) K-space encoding via a weighted stack of spirals provides 3D metabolic mapping with flexible scan times. Simulations, phantom and in vivo experiments prove that our MEGA-LASER sequence enables 3D mapping of GABA+ and Glx (Glutamate+Gluatmine), by providing 1.66 times larger signal for the 3.02ppm multiplet of GABA+ compared to MEGA-PRESS, leading to clinically feasible scan times for 3D brain imaging. Hence, our sequence allows accurate and robust 3D-mapping of brain GABA+ and Glx levels to be performed at clinical 3T MR scanners for use in neuroscience and clinical applications.
Collapse
Affiliation(s)
- Wolfgang Bogner
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; MRCE, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Vienna, Austria
| | - Borjan Gagoski
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Aaron T Hess
- Department of Cardiovascular Medicine, John Radcliffe Hospital, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK
| | | | - M Dylan Tisdall
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Andre J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Bernhard Strasser
- MRCE, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Vienna, Austria
| | - Małgorzata Marjańska
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Siegfried Trattnig
- MRCE, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Vienna, Austria
| | - Ellen Grant
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Bruce Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Ovidiu C Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
77
|
Automatic voxel positioning for MRS at 7 T. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2014; 28:259-70. [PMID: 25408107 DOI: 10.1007/s10334-014-0469-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Revised: 10/16/2014] [Accepted: 10/21/2014] [Indexed: 10/24/2022]
Abstract
OBJECT The purpose of this study was to test, for the first time, whether spectroscopy voxels could be positioned automatically with high accuracy and reproducibility in ultrahigh-field longitudinal magnetic resonance spectroscopy (MRS) studies. MATERIALS AND METHODS MRS voxels were automatically positioned in two cingulate subregions of 12 healthy subjects using a vendor-provided automatic voxel positioning (AutoAlign) technique, and were manually placed in the same regions of 10 healthy subjects by an experienced technician in three 7 T MRS scan sessions. Different coils were used for manual (24-channel coil) and automatic (32-channel coil) voxel placement, and the effects of signal-to-noise-ratio differences on the spectra were considered. RESULTS Over three scan sessions and two regions scanned for each subject, a mean voxel geometric overlap ratio of 0.91 for automatic positioning reflected accurate voxel alignment, while the geometric overlap ratio was only 0.70 for voxels placed manually. Comparable voxel positions among the three scan sessions (p > 0.05) indicated high reproducibility of automatic voxel alignment. In comparison, significant voxel displacement among scan sessions (p < 0.05) was found using manual voxel positioning. CONCLUSIONS In view of the highly accurate and reproducible voxel alignment with automatic voxel positioning, we propose the application of automatic rather than manual voxel positioning in future ultrahigh-field longitudinal MRS studies.
Collapse
|
78
|
Juchem C, Umesh Rudrapatna S, Nixon TW, de Graaf RA. Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla. Neuroimage 2014; 105:462-72. [PMID: 25462795 DOI: 10.1016/j.neuroimage.2014.11.011] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2014] [Revised: 10/16/2014] [Accepted: 11/04/2014] [Indexed: 12/31/2022] Open
Abstract
Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large-scale brain connectivity in vivo. As such, DYNAMITE shimming has the potential to replace conventional SH shim systems in human MR scanners.
Collapse
Affiliation(s)
- Christoph Juchem
- Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
| | - S Umesh Rudrapatna
- Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA
| | - Terence W Nixon
- Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA
| | - Robin A de Graaf
- Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA
| |
Collapse
|
79
|
Hinds O, Wighton P, Tisdall MD, Hess A, Breiter H, van der Kouwe A. NEUROFEEDBACK USING FUNCTIONAL SPECTROSCOPY. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY 2014; 24:138-148. [PMID: 24999293 PMCID: PMC4077662 DOI: 10.1002/ima.22088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Neurofeedback based on real-time measurement of the blood oxygenation level-dependent (BOLD) signal has potential for treatment of neurological disorders and behavioral enhancement. Commonly employed methods are based on functional magnetic resonance imaging (fMRI) sequences that sacrifice speed and accuracy for whole-brain coverage, which is unnecessary in most applications. We present multi-voxel functional spectroscopy (MVFS): a system for computing the BOLD signal from multiple volumes of interest (VOI) in real-time that improves speed and accuracy of neurofeedback. MVFS consists of a functional spectroscopy (FS) pulse sequence, a BOLD reconstruction component, a neural activation estimator, and a stimulus system. The FS pulse sequence is a single-voxel, magnetic resonance spectroscopy sequence without water suppression that has been extended to allow acquisition of a different VOI at each repetition and real-time subject head motion compensation. The BOLD reconstruction component determines the T2* decay rate, which is directly related to BOLD signal strength. The neural activation estimator discounts nuisance signals and scales the activation relative to the amount of ROI noise. Finally, the neurofeedback system presents neural activation-dependent stimuli to experimental subjects with an overall delay of less than 1s. Here we present the MVFS system, validation of certain components, examples of its usage in a practical application, and a direct comparison of FS and echo-planar imaging BOLD measurements. We conclude that in the context of realtime BOLD imaging, MVFS can provide superior accuracy and temporal resolution compared with standard fMRI methods.
Collapse
Affiliation(s)
- Oliver Hinds
- Athinoula A. Martinos Imaging Center at the McGovern Institute for Brain Research, Massachusetts Institute of Technology
| | - Paul Wighton
- Athinoula A. Martinos Imaging Center, Department of Radiology, Massachusetts General Hospital ; Harvard Medical School
| | - M Dylan Tisdall
- Athinoula A. Martinos Imaging Center, Department of Radiology, Massachusetts General Hospital ; Harvard Medical School
| | - Aaron Hess
- Department of Human Biology, MRC/UCT Medical Imaging Research Unit, University of Cape Town, South Africa
| | - Hans Breiter
- Department of Psychiatry, Massachusetts General Hospital ; Department of Psychiatry and Behavioral Sciences, Northwestern University Feinberg School of Medicine
| | - André van der Kouwe
- Athinoula A. Martinos Imaging Center, Department of Radiology, Massachusetts General Hospital ; Harvard Medical School
| |
Collapse
|
80
|
Hess AT, Jacobson SW, Jacobson JL, Molteno CD, van der Kouwe AJ, Meintjes EM. A comparison of spectral quality in magnetic resonance spectroscopy data acquired with and without a novel EPI-navigated PRESS sequence in school-aged children with fetal alcohol spectrum disorders. Metab Brain Dis 2014; 29:323-32. [PMID: 24488204 PMCID: PMC4024336 DOI: 10.1007/s11011-014-9487-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 01/13/2014] [Indexed: 11/25/2022]
Abstract
Single voxel spectroscopy (SVS) can generate useful information regarding metabolite concentrations provided that the MR signal can be averaged over several minutes during which the subject remains stationary. This requirement can be particularly challenging for children who cannot otherwise be scanned without sedation. To address this problem we developed an EPI volume navigated (vNav) SVS PRESS sequence, which applies real-time head pose (location and orientation), frequency, and first-order B0 shim adjustments. A water-independent preprocessing algorithm removes residual frequency and phase shifts resulting from within-TR movements. We compare results and performance of the standard and vNav PRESS sequences in a sample of 9- to 10-year-olds from a South African cohort of children with fetal alcohol spectrum disorders (FASD) and healthy controls. Magnetic resonance spectroscopy (MRS) data in the deep cerebellar nuclei were initially acquired with the standard PRESS sequence. The children were re-scanned 1 year later with the vNav PRESS sequence. Good quality data were acquired in 73% using the vNav PRESS sequence, compared to only 50% for the standard PRESS sequence. Additionally, tighter linewidths and smaller variances in the measured concentrations were observed. These findings confirm previous reports demonstrating the efficacy of our innovative vNav sequence with healthy volunteers and young children with HIV and expand its application to a school-aged population with FASD-disorders often associated with attention problems and hyperactivity. This study provides the most direct evidence to date regarding degree to which these new methods can improve data quality in research studies employing MRS.
Collapse
Affiliation(s)
- Aaron T. Hess
- MRC/UCT Medical Imaging Research Unit, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
- University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK
| | - Sandra W. Jacobson
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
- Department of Psychiatry and Behavioral Neurosciences, Wayne State University School of Medicine, Detroit, Michigan, USA
- Department of Psychiatry and Mental Health, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| | - Joseph L. Jacobson
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
- Department of Psychiatry and Behavioral Neurosciences, Wayne State University School of Medicine, Detroit, Michigan, USA
- Department of Psychiatry and Mental Health, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| | - Christopher D. Molteno
- Department of Psychiatry and Mental Health, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| | - André J.W. van der Kouwe
- Department of Radiology and Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Ernesta M. Meintjes
- MRC/UCT Medical Imaging Research Unit, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| |
Collapse
|
81
|
du Plessis L, Jacobson JL, Jacobson SW, Hess AT, van der Kouwe A, Avison MJ, Molteno CD, Stanton ME, Stanley JA, Peterson BS, Meintjes EM. An in vivo 1H magnetic resonance spectroscopy study of the deep cerebellar nuclei in children with fetal alcohol spectrum disorders. Alcohol Clin Exp Res 2014; 38:1330-8. [PMID: 24655149 DOI: 10.1111/acer.12380] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Accepted: 01/10/2014] [Indexed: 11/29/2022]
Abstract
BACKGROUND Prenatal alcohol exposure has been linked to impairment in cerebellar structure and function, including eyeblink conditioning. The deep cerebellar nuclei, which play a critical role in cerebellar-mediated learning, receive extensive inputs from brain stem and cerebellar cortex and provide the point of origin for most of the output fibers to other regions of the brain. We used in vivo (1) H magnetic resonance spectroscopy (MRS) to examine effects of prenatal alcohol exposure on neurochemistry in this important cerebellar region. METHODS MRS data from the deep cerebellar nuclei were acquired from 37 children with heavy prenatal alcohol exposure and 17 non- or minimally exposed controls from the Cape Coloured (mixed ancestry) community in Cape Town, South Africa. RESULTS Increased maternal alcohol consumption around time of conception was associated with lower N-Acetylaspartate (NAA) levels in the deep nuclei (r = -0.33, p < 0.05). Higher levels of alcohol consumption during pregnancy were related to lower levels of the choline-containing metabolites (r = -0.37, p < 0.01), glycerophosphocholine plus phosphocholine (Cho). Alcohol consumption levels both at conception (r = 0.35, p < 0.01) and during pregnancy (r = 0.38, p < 0.01) were related to higher levels of glutamate plus glutamine (Glx). All these effects continued to be significant after controlling for potential confounders. CONCLUSIONS The lower NAA levels seen in relation to prenatal alcohol exposure may reflect impaired neuronal integrity in the deep cerebellar nuclei. Our finding of lower Cho points to disrupted Cho metabolism of membrane phospholipids, reflecting altered neuropil development with potentially reduced content of dendrites and synapses. The alcohol-related alterations in Glx may suggest a disruption of the glutamate-glutamine cycling involved in glutamatergic excitatory neurotransmission.
Collapse
Affiliation(s)
- Lindie du Plessis
- MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town, South Africa; Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
82
|
Abstract
Magnetic resonance spectroscopy (MRS) is indicated in the imaging protocol of the patient with epilepsy to screen for metabolic derangements such as inborn errors of metabolism and to characterize masses that may be equivocal on conventional magnetic resonance imaging for dysplasia versus neoplasia. Single-voxel MRS with echo time of 35 milliseconds may be used for this purpose as a quick screening tool in the epilepsy imaging protocol. MRS is useful in the evaluation of both focal and generalized epilepsy.
Collapse
|
83
|
Near J, Edden R, Evans CJ, Paquin R, Harris A, Jezzard P. Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain. Magn Reson Med 2014; 73:44-50. [PMID: 24436292 DOI: 10.1002/mrm.25094] [Citation(s) in RCA: 188] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 11/29/2013] [Accepted: 12/04/2013] [Indexed: 11/08/2022]
Abstract
PURPOSE Frequency and phase drifts are a common problem in the acquisition of in vivo magnetic resonance spectroscopy (MRS) data. If not accounted for, frequency and phase drifts will result in artifactual broadening of spectral peaks, distortion of spectral lineshapes, and a reduction in signal-to-noise ratio (SNR). We present herein a new method for estimating and correcting frequency and phase drifts in in vivo MRS data. METHODS We used a simple method of fitting each spectral average to a reference scan (often the first average in the series) in the time domain through adjustment of frequency and phase terms. Due to the similarity with image registration, this method is referred to as "spectral registration." Using simulated data with known frequency and phase drifts, the performance of spectral registration was compared with two existing methods at various SNR levels. RESULTS Spectral registration performed well in comparison with the other methods tested in terms of both frequency and phase drift estimation. CONCLUSIONS Spectral registration provides an effective method for frequency and phase drift correction. It does not involve the collection of navigator echoes, and does not rely on any specific resonances, such as residual water or creatine, making it highly versatile.
Collapse
Affiliation(s)
- Jamie Near
- Douglas Mental Health University Institute and Department of Psychiatry, McGill University, Montreal, Canada
| | - Richard Edden
- Division of Neuroradiology, Russel H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - C John Evans
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff University, Cardiff, UK
| | | | - Ashley Harris
- Division of Neuroradiology, Russel H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Peter Jezzard
- Centre for Functional Magnetic Resonance Imaging of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| |
Collapse
|
84
|
Bogner W, Hess AT, Gagoski B, Tisdall MD, van der Kouwe AJW, Trattnig S, Rosen B, Andronesi OC. Real-time motion- and B0-correction for LASER-localized spiral-accelerated 3D-MRSI of the brain at 3T. Neuroimage 2013; 88:22-31. [PMID: 24201013 DOI: 10.1016/j.neuroimage.2013.09.034] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 09/06/2013] [Accepted: 09/14/2013] [Indexed: 02/03/2023] Open
Abstract
The full potential of magnetic resonance spectroscopic imaging (MRSI) is often limited by localization artifacts, motion-related artifacts, scanner instabilities, and long measurement times. Localized adiabatic selective refocusing (LASER) provides accurate B1-insensitive spatial excitation even at high magnetic fields. Spiral encoding accelerates MRSI acquisition, and thus, enables 3D-coverage without compromising spatial resolution. Real-time position- and shim/frequency-tracking using MR navigators correct motion- and scanner instability-related artifacts. Each of these three advanced MRI techniques provides superior MRSI data compared to commonly used methods. In this work, we integrated in a single pulse sequence these three promising approaches. Real-time correction of motion, shim, and frequency-drifts using volumetric dual-contrast echo planar imaging-based navigators were implemented in an MRSI sequence that uses low-power gradient modulated short-echo time LASER localization and time efficient spiral readouts, in order to provide fast and robust 3D-MRSI in the human brain at 3T. The proposed sequence was demonstrated to be insensitive to motion- and scanner drift-related degradations of MRSI data in both phantoms and volunteers. Motion and scanner drift artifacts were eliminated and excellent spectral quality was recovered in the presence of strong movement. Our results confirm the expected benefits of combining a spiral 3D-LASER-MRSI sequence with real-time correction. The new sequence provides accurate, fast, and robust 3D metabolic imaging of the human brain at 3T. This will further facilitate the use of 3D-MRSI for neuroscience and clinical applications.
Collapse
Affiliation(s)
- Wolfgang Bogner
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; MR Center of Excellence, Department of Radiology, Medical University Vienna, Vienna, Austria.
| | - Aaron T Hess
- Department of Cardiovascular Medicine, John Radcliffe Hospital, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK
| | - Borjan Gagoski
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - M Dylan Tisdall
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Andre J W van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Siegfried Trattnig
- MR Center of Excellence, Department of Radiology, Medical University Vienna, Vienna, Austria
| | - Bruce Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Ovidiu C Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
85
|
Hess AT, van der Kouwe AJW, Mbugua KK, Laughton B, Meintjes EM. Quality of 186 child brain spectra using motion and B0 shim navigated single voxel spectroscopy. J Magn Reson Imaging 2013; 40:958-65. [PMID: 24924772 DOI: 10.1002/jmri.24436] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Accepted: 09/09/2013] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To evaluate B0 shim and motion navigated single voxel spectroscopy in children. Assess the repeatability of metabolite concentrations in three regions: medial frontal grey matter, peritrigonal white matter, and basal ganglia. Determine the extent of intra- and interacquisition movement in this population. METHODS Linewidth and signal to noise ratio were calculated to assess spectral quality of 186 spectra at 3 Tesla. Repeatability was assessed on 31 repeat scans. Navigator images were used to assess localization errors, while navigator motion and shim logs were used to demonstrate the efficacy of correction needed during the scans. RESULTS Average linewidths ± standard deviations of N-acetyl aspartate are 3.8 ± 0.6 Hz, 4.4 ± 0.5 Hz, and 4.7 ± 0.8 Hz in each region, respectively. Scan-to-scan measurement variance in metabolite concentrations closely resembled the expected variance. A total of 73% and 32% of children moved before and during the acquisition, causing a voxel shift of more than 10% of the voxel volume, 1.5 mm. The predominant movement directions were sliding out of the coil and nodding (up-down rotation). First-order B0 corrections were significant (>10 μT/m) in 18 % of acquisitions. CONCLUSION Prospective motion and B0 correction provides high quality repeatable spectra. The study found that most children moved between acquisitions and a substantial number moved during acquisitions.
Collapse
Affiliation(s)
- Aaron T Hess
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | | | | | | | | |
Collapse
|
86
|
Abstract
Magnetic resonance imaging (MRI) has been used to image the in utero fetus for the past 3 decades. Although not as commonplace as other patient-oriented MRI, it is a growing field and demonstrating a role in the clinical care of the fetus. Indeed, the body of literature involving fetal MRI exceeds 3000 published articles. Indeed, there is interest in accessing even the healthy fetus with MRI to further understand the development of humans during the fetal stage. On the horizon is fetal imaging using 3.0-T clinical systems. Although a clear path is not necessarily determined, experiments, theoretical calculations, advances in pulse sequence design, new hardware, and experience from imaging at 1.5 T help define the path.
Collapse
Affiliation(s)
- Robert C Welsh
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109-5667, USA.
| | | | | |
Collapse
|
87
|
Andronesi OC, Rapalino O, Gerstner E, Chi A, Batchelor TT, Cahill DP, Sorensen AG, Rosen BR. Detection of oncogenic IDH1 mutations using magnetic resonance spectroscopy of 2-hydroxyglutarate. J Clin Invest 2013; 123:3659-63. [PMID: 23999439 DOI: 10.1172/jci67229] [Citation(s) in RCA: 117] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The investigation of metabolic pathways disturbed in isocitrate dehydrogenase (IDH) mutant tumors revealed that the hallmark metabolic alteration is the production of D-2-hydroxyglutarate (D-2HG). The biological impact of D-2HG strongly suggests that high levels of this metabolite may play a central role in propagating downstream the effects of mutant IDH, leading to malignant transformation of cells. Hence, D-2HG may be an ideal biomarker for both diagnosing and monitoring treatment response targeting IDH mutations. Magnetic resonance spectroscopy (MRS) is well suited to the task of noninvasive D-2HG detection, and there has been much interest in developing such methods. Here, we review recent efforts to translate methodology using MRS to reliably measure in vivo D-2HG into clinical research.
Collapse
Affiliation(s)
- Ovidiu C Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | | | | | | | | | | | | | | |
Collapse
|
88
|
Real-time automated spectral assessment of the BOLD response for neurofeedback at 3 and 7T. J Neurosci Methods 2013; 218:148-60. [PMID: 23685226 DOI: 10.1016/j.jneumeth.2013.05.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2013] [Revised: 03/29/2013] [Accepted: 05/06/2013] [Indexed: 11/21/2022]
Abstract
Echo-planar imaging is the dominant functional MRI data acquisition scheme for evaluating the BOLD signal. To date, it remains the only approach providing neurofeedback from spatially localized brain activity. Real-time functional single-voxel proton spectroscopy (fSVPS) may be an alternative for spatially specific BOLD neurofeedback at 7T because it allows for a precise estimation of the local T2* signal, EPI-specific artifacts may be avoided, and the signal contrast may increase. In order to explore and optimize this alternative neurofeedback approach, we tested fully automated real-time fSVPS spectral estimation procedures to approximate T2* BOLD signal changes from the unsuppressed water peak, i.e. lorentzian non-linear complex spectral fit (LNLCSF) in frequency and frequency-time domain. The proposed approaches do not require additional spectroscopic localizers in contrast to conventional T2* approximation based on linear regression of the free induction decay (FID). For methods comparison, we evaluated quality measures for signals from the motor and the visual cortex as well as a real-time feedback condition at high (3T) and at ultra-high (7T) magnetic field strengths. Using these methods, we achieved reliable and fast water peak spectral parameter estimations. At 7T, we observed an absolute increase of spectra line narrowing due to the BOLD effect, but quality measures did not improve due to artifactual line broadening. Overall, the automated fSVPS approach can be used to assess dynamic spectral changes in real-time, and to provide localized T2* neurofeedback at 3 and 7T.
Collapse
|
89
|
Maclaren J, Herbst M, Speck O, Zaitsev M. Prospective motion correction in brain imaging: a review. Magn Reson Med 2012; 69:621-36. [PMID: 22570274 DOI: 10.1002/mrm.24314] [Citation(s) in RCA: 251] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2012] [Revised: 03/30/2012] [Accepted: 04/04/2012] [Indexed: 11/11/2022]
Abstract
Motion correction in magnetic resonance imaging by real-time adjustment of the imaging pulse sequence was first proposed more than 20 years ago. Recent advances have resulted from combining real-time correction with new navigator and external tracking mechanisms capable of quantifying rigid-body motion in all 6 degrees of freedom. The technique is now often referred to as "prospective motion correction." This article describes the fundamentals of prospective motion correction and reviews the latest developments in its application to brain imaging and spectroscopy. Although emphasis is placed on the brain as the organ of interest, the same principles apply whenever the imaged object can be approximated as a rigid body. Prospective motion correction can be used with most MR sequences, so it has potential to make a large impact in clinical routine. To maximize the benefits obtained from the technique, there are, however, several challenges still to be met. These include practical implementation issues, such as obtaining tracking data with minimal delay, and more fundamental problems, such as the magnetic field distortions caused by a moving object. This review discusses these challenges and summarizes the state of the art. We hope that this work will motivate further developments in prospective motion correction and help the technique to reach its full potential.
Collapse
Affiliation(s)
- Julian Maclaren
- Medical Physics, Department of Radiology, University Medical Center Freiburg, Freiburg, Germany.
| | | | | | | |
Collapse
|
90
|
Hess AT, Andronesi OC, Tisdall MD, Sorensen AG, van der Kouwe AJW, Meintjes EM. Real-time motion and B0 correction for localized adiabatic selective refocusing (LASER) MRSI using echo planar imaging volumetric navigators. NMR IN BIOMEDICINE 2012; 25:347-58. [PMID: 21796711 PMCID: PMC3261340 DOI: 10.1002/nbm.1756] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Revised: 05/24/2011] [Accepted: 06/01/2011] [Indexed: 05/11/2023]
Abstract
A method is presented to correct the effects of motion and motion-related B(0) perturbations on spectroscopic imaging in real time through the use of a volumetric navigator. It is demonstrated that, for an axial slice, lifting the chin significantly disrupts the B(0) homogeneity in the zero-order (frequency), first-order Y (coronal) axis and second-order ZY term. This volumetric navigator is able to measure and correct in real time both head pose and zero- to first-order B(0) inhomogeneities. The volumetric navigator was validated in six volunteers who deliberately lifted and then dropped their chin during the scan. These scans show that motion correction alone is not sufficient to recover the spectral quality. By applying real-time shim adjustments, spectral quality was fully recovered to linewidths below 0.08 ppm and the signal-to-noise ratio to within acceptable limits in five of six subjects. In the sixth subject, 83% of the spectra within the volume of interest were recovered, compared with the worst case nonshim-corrected scan, where none of the voxels fell within these quality bounds. It is shown that the use of a volumetric navigator comes at no additional cost to the scan time or spectral signal-to-noise ratio.
Collapse
Affiliation(s)
- Aaron T Hess
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa.
| | | | | | | | | | | |
Collapse
|
91
|
Alhamud A, Tisdall MD, Hess AT, Hasan KM, Meintjes EM, van der Kouwe AJW. Volumetric navigators for real-time motion correction in diffusion tensor imaging. Magn Reson Med 2012; 68:1097-108. [PMID: 22246720 DOI: 10.1002/mrm.23314] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2011] [Revised: 10/24/2011] [Accepted: 11/14/2011] [Indexed: 11/11/2022]
Abstract
Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the contrast is independent of the b-value, to perform prospective motion correction in diffusion weighted images, without having to reacquire volumes during which motion occurred, unless motion exceeded some preset thresholds. Water phantom and human brain data were acquired using the standard and navigated diffusion sequences, and the mean and whole brain histogram of the fractional anisotropy and mean diffusivity were analyzed. Our results show that adding the navigator does not influence the diffusion sequence. With head motion, the whole brain histogram-fractional anisotropy shows a shift toward lower anisotropy with a significant decrease in both the mean fractional anisotropy and the fractional anisotropy histogram peak location (P<0.01), whereas the whole brain histogram-mean diffusivity shows a shift toward higher diffusivity with a significant increase in the mean diffusivity (P<0.01), even after retrospective motion correction. These changes in the mean and the shape of the histograms are recovered substantially in the prospective motion corrected data acquired using the navigated sequence.
Collapse
Affiliation(s)
- A Alhamud
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, Observatory, South Africa.
| | | | | | | | | | | |
Collapse
|
92
|
Keating B, Ernst T. Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy. Magn Reson Med 2012; 68:1339-45. [PMID: 22851160 DOI: 10.1002/mrm.24129] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2011] [Revised: 11/03/2011] [Accepted: 11/30/2011] [Indexed: 11/08/2022]
Abstract
Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear variations in B₀ across a small volume using two-dimensional excitations. The new field mapping technique was integrated into a prospectively motion-corrected single-voxel ¹H magnetic resonance spectroscopy sequence. Interference with the magnetic resonance spectroscopy measurement was negligible, and there was no penalty in scan time. Frequency shifts were also measured continuously, and both frequency and first-order shim corrections were applied in real time. Phantom experiments and in vivo studies demonstrated that the resulting motion- and shim-corrected sequence is able to mitigate line broadening and maintain spectral quality even in the presence of large-amplitude subject motion.
Collapse
Affiliation(s)
- Brian Keating
- Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA.
| | | |
Collapse
|
93
|
Tisdall MD, Hess AT, Reuter M, Meintjes EM, Fischl B, van der Kouwe AJW. Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI. Magn Reson Med 2011; 68:389-99. [PMID: 22213578 DOI: 10.1002/mrm.23228] [Citation(s) in RCA: 276] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Revised: 08/16/2011] [Accepted: 08/31/2011] [Indexed: 11/07/2022]
Abstract
We introduce a novel method of prospectively compensating for subject motion in neuroanatomical imaging. Short three-dimensional echo-planar imaging volumetric navigators are embedded in a long three-dimensional sequence, and the resulting image volumes are registered to provide an estimate of the subject's location in the scanner at a cost of less than 500 ms, ~ 1% change in contrast, and ~3% change in intensity. This time fits well into the existing gaps in sequences routinely used for neuroimaging, thus giving a motion-corrected sequence with no extra time required. We also demonstrate motion-driven selective reacquisition of k-space to further compensate for subject motion. We perform multiple validation experiments to evaluate accuracy, navigator impact on tissue intensity/contrast, and the improvement in final output. The complete system operates without adding additional hardware to the scanner and requires no external calibration, making it suitable for high-throughput environments.
Collapse
Affiliation(s)
- M Dylan Tisdall
- Athinoula A Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
| | | | | | | | | | | |
Collapse
|
94
|
Gruber S, Debski BK, Pinker K, Chmelik M, Grabner G, Helbich T, Trattnig S, Bogner W. Three-dimensional Proton MR Spectroscopic Imaging at 3 T for the Differentiation of Benign and Malignant Breast Lesions. Radiology 2011; 261:752-761. [DOI: 10.1148/radiol.11102096] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
95
|
Abstract
Echo-planar imaging (EPI) in fMRI is regularly used to reveal BOLD activation in presubscribed regions of interest (ROI). The response is mediated by relative changes in T2* which appear as changes in the image pixel intensities. We have proposed an application of functional single-voxel proton spectroscopy (fSVPS) for real-time studies at ultra-high MR field which can be comparable to the EPI BOLD fMRI technique. A spin-echo SVPS protocol without water suppression was acquired with 310 repetitions on a 7T Siemens MR scanner (TE/TR = 20/1000 ms, flip angle α = 90°, voxel size 10 × 10 × 10 mm3). Transmitter reference voltage was optimized for the voxel location. Spectral processing of the water signal free induction decay (FID) using log-linear regression was used to estimate the T2* change between rest and activation of a functional task. The FID spectrum was filtered with a Gaussian window around the water peak, and log-linear regression was optimized for the particular ROI by adoption of the linearization length. The spectroscopic voxel was positioned on an ROI defined from a real-time fMRI EPI BOLD localizer. Additional online signal processing algorithms performed signal drift removal (exponential moving average), despiking and low-pass filtering (modified Kalman filter) and, finally, the dynamic feedback signal normalization. Two functional tasks were used to estimate the sensitivity of the SVPS method compared to BOLD signal changes, namely the primary motor cortex (PMC, left hand finger tapping) and visual cortex (VC, blinking checkerboard). Four healthy volunteers performed these tasks and an additional session using real-time signal feedback modulating their activation level of the PMC. Results show that single voxel spectroscopy is able to provide a good and reliable estimation of the ΒΟLD signal changes. Small data size and FID signal processing instead of processing entire brain volumes as well as more information revealed from the acquired total water spectrum, i.e., direct estimation of the T2* values and B0 changes, make SVPS proton spectroscopy suitable and advantageous for real-time neurofeedback studies. Particular challenges of ultra-high field spectroscopy due to the non-linearity in the spectral information, e.g., poor main magnetic field homogeneity and the absence of motion correction for the SVPS sequence may lead to the special artifacts in the control signal which still need to be addressed. The contrast to noise ratio (CNR), experimental statistic (t-values) and percent signal change were used as quality parameters to estimate the method performance. The potential and challenges of the spectroscopic approach for fMRI studies needs to be further investigated.
Collapse
|
96
|
Lange T, Maclaren J, Buechert M, Zaitsev M. Spectroscopic imaging with prospective motion correction and retrospective phase correction. Magn Reson Med 2011; 67:1506-14. [PMID: 22135041 DOI: 10.1002/mrm.23136] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Revised: 07/12/2011] [Accepted: 07/13/2011] [Indexed: 11/09/2022]
Abstract
Motion-induced artifacts are much harder to recognize in magnetic resonance spectroscopic imaging than in imaging experiments and can therefore lead to erroneous interpretation. A method for prospective motion correction based on an optical tracking system has recently been proposed and has already been successfully applied to single voxel spectroscopy. In this work, the utility of prospective motion correction in combination with retrospective phase correction is evaluated for spectroscopic imaging in the human brain. Retrospective phase correction, based on the interleaved reference scan method, is used to correct for motion-induced frequency shifts and ensure correct phasing of the spectra across the whole spectroscopic imaging slice. It is demonstrated that the presented correction methodology can reduce motion-induced degradation of spectroscopic imaging data.
Collapse
Affiliation(s)
- Thomas Lange
- Medical Physics, Department of Radiology, University Medical Center Freiburg, Freiburg, Germany.
| | | | | | | |
Collapse
|