51
|
Rahal L, Thibaut M, Rivals I, Claron J, Lenkei Z, Sitt JD, Tanter M, Pezet S. Ultrafast ultrasound imaging pattern analysis reveals distinctive dynamic brain states and potent sub-network alterations in arthritic animals. Sci Rep 2020; 10:10485. [PMID: 32591574 PMCID: PMC7320008 DOI: 10.1038/s41598-020-66967-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 05/29/2020] [Indexed: 01/20/2023] Open
Abstract
Chronic pain pathologies, which are due to maladaptive changes in the peripheral and/or central nervous systems, are debilitating diseases that affect 20% of the European adult population. A better understanding of the mechanisms underlying this pathogenesis would facilitate the identification of novel therapeutic targets. Functional connectivity (FC) extracted from coherent low-frequency hemodynamic fluctuations among cerebral networks has recently brought light on a powerful approach to study large scale brain networks and their disruptions in neurological/psychiatric disorders. Analysis of FC is classically performed on averaged signals over time, but recently, the analysis of the dynamics of FC has also provided new promising information. Keeping in mind the limitations of animal models of persistent pain but also the powerful tool they represent to improve our understanding of the neurobiological basis of chronic pain pathogenicity, this study aimed at defining the alterations in functional connectivity, in a clinically relevant animal model of sustained inflammatory pain (Adjuvant-induced Arthritis) in rats by using functional ultrasound imaging, a neuroimaging technique with a unique spatiotemporal resolution (100 μm and 2 ms) and sensitivity. Our results show profound alterations of FC in arthritic animals, such as a subpart of the somatomotor (SM) network, occurring several weeks after the beginning of the disease. Also, we demonstrate for the first time that dynamic functional connectivity assessed by ultrasound can provide quantitative and robust information on the dynamic pattern that we define as brain states. While the main state consists of an overall synchrony of hemodynamic fluctuations in the SM network, arthritic animal spend statistically more time in two other states, where the fluctuations of the primary sensory cortex of the inflamed hind paws show asynchrony with the rest of the SM network. Finally, correlating FC changes with pain behavior in individual animals suggest links between FC alterations and either the cognitive or the emotional aspects of pain. Our study introduces fUS as a new translational tool for the enhanced understanding of the dynamic pain connectome and brain plasticity in a major preclinical model of chronic pain.
Collapse
Affiliation(s)
- Line Rahal
- Laboratory of Brain Plasticity, ESPCI Paris, PSL Research University, CNRS UMR 8249, 10 rue Vauquelin, 75005, Paris, France
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| | - Miguel Thibaut
- Laboratory of Brain Plasticity, ESPCI Paris, PSL Research University, CNRS UMR 8249, 10 rue Vauquelin, 75005, Paris, France
| | - Isabelle Rivals
- Equipe de Statistique Appliquée, ESPCI Paris, PSL Research University, UMRS 1158, 10 rue Vauquelin, 75005, Paris, France
| | - Julien Claron
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| | - Zsolt Lenkei
- Laboratory of Brain Plasticity, ESPCI Paris, PSL Research University, CNRS UMR 8249, 10 rue Vauquelin, 75005, Paris, France
- Center of Psychiatry and Neurosciences, INSERM U894, 102 rue de la Santé, 75014, Paris, France
| | - Jacobo D Sitt
- Institut du Cerveau et de la Moelle, INSERM U1127, CNRS UMR 7225, Sorbonne University, UPMC Univ Paris 06 UMR, S 1127, Paris, France
| | - Mickael Tanter
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| | - Sophie Pezet
- Laboratory of Brain Plasticity, ESPCI Paris, PSL Research University, CNRS UMR 8249, 10 rue Vauquelin, 75005, Paris, France.
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France.
| |
Collapse
|
52
|
Aydin AK, Haselden WD, Goulam Houssen Y, Pouzat C, Rungta RL, Demené C, Tanter M, Drew PJ, Charpak S, Boido D. Transfer functions linking neural calcium to single voxel functional ultrasound signal. Nat Commun 2020; 11:2954. [PMID: 32528069 PMCID: PMC7290037 DOI: 10.1038/s41467-020-16774-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Accepted: 05/11/2020] [Indexed: 12/13/2022] Open
Abstract
Functional ultrasound imaging (fUS) is an emerging technique that detects changes of cerebral blood volume triggered by brain activation. Here, we investigate the extent to which fUS faithfully reports local neuronal activation by combining fUS and two-photon microscopy (2PM) in a co-registered single voxel brain volume. Using a machine-learning approach, we compute and validate transfer functions between dendritic calcium signals of specific neurons and vascular signals measured at both microscopic (2PM) and mesoscopic (fUS) levels. We find that transfer functions are robust across a wide range of stimulation paradigms and animals, and reveal a second vascular component of neurovascular coupling upon very strong stimulation. We propose that transfer functions can be considered as reliable quantitative reporters to follow neurovascular coupling dynamics. Neurovascular coupling refers to changes in cerebral blood flow in response to neuronal stimulation, but to what extent this change can report neuronal activation is not known. Here the authors develop transfer functions between neural calcium signals and functional ultrasound changes in blood volume in co-registered single voxel brain volumes.
Collapse
Affiliation(s)
- Ali-Kemal Aydin
- INSERM U1128, Laboratory of Neurophysiology and New Microscopy, Université de Paris, Paris, France.,INSERM, CNRS, Institut de la Vision, Sorbonne Université, Paris, France
| | - William D Haselden
- Medical Scientist Training Program and Neuroscience Graduate Program, The Pennsylvania State University, University Park, PA, USA
| | - Yannick Goulam Houssen
- INSERM U1128, Laboratory of Neurophysiology and New Microscopy, Université de Paris, Paris, France
| | - Christophe Pouzat
- MAP5, Mathématiques Appliquées Paris 5, CNRS UMR 8145, Paris, France
| | - Ravi L Rungta
- INSERM U1128, Laboratory of Neurophysiology and New Microscopy, Université de Paris, Paris, France.,INSERM, CNRS, Institut de la Vision, Sorbonne Université, Paris, France
| | - Charlie Demené
- Physics for Medicine, ESPCI, INSERM, CNRS, PSL Research University, Paris, France
| | - Mickael Tanter
- Physics for Medicine, ESPCI, INSERM, CNRS, PSL Research University, Paris, France
| | - Patrick J Drew
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, USA
| | - Serge Charpak
- INSERM U1128, Laboratory of Neurophysiology and New Microscopy, Université de Paris, Paris, France. .,INSERM, CNRS, Institut de la Vision, Sorbonne Université, Paris, France.
| | - Davide Boido
- INSERM U1128, Laboratory of Neurophysiology and New Microscopy, Université de Paris, Paris, France. .,NeuroSpin, Bât 145, Commissariat à l'Energie Atomique-Saclay Center, 91191, Gif-sur-Yvette, France.
| |
Collapse
|
53
|
Abstract
Nowadays, several techniques exist to study and better understand how the brain works (fMRI, EEG, electrophysiology, etc.). Each has its own advantages and disadvantages (spatiotemporal resolution, maximal recording depth, signal-to-noise ratio, etc.). In this article, we show that the new functional ultrasound (fUS) imaging technique is appropriate to record and map brain activity in awake primates on a scale previously unreachable. It allows distinguishing patterns similar to ocular dominance bands in the visual cortex through all layers of the cortex, which was impossible before with common techniques. This paper demonstrates the utility of fUS imaging for studying brain activity in awake primates and its interest to all neuroscientists. Deep regions of the brain are not easily accessible to investigation at the mesoscale level in awake animals or humans. We have recently developed a functional ultrasound (fUS) technique that enables imaging hemodynamic responses to visual tasks. Using fUS imaging on two awake nonhuman primates performing a passive fixation task, we constructed retinotopic maps at depth in the visual cortex (V1, V2, and V3) in the calcarine and lunate sulci. The maps could be acquired in a single-hour session with relatively few presentations of the stimuli. The spatial resolution of the technology is illustrated by mapping patterns similar to ocular dominance (OD) columns within superficial and deep layers of the primary visual cortex. These acquisitions using fUS suggested that OD selectivity is mostly present in layer IV but with extensions into layers II/III and V. This imaging technology provides a new mesoscale approach to the mapping of brain activity at high spatiotemporal resolution in awake subjects within the whole depth of the cortex.
Collapse
|
54
|
Sauvage J, Poree J, Rabut C, Ferin G, Flesch M, Rosinski B, Nguyen-Dinh A, Tanter M, Pernot M, Deffieux T. 4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:1884-1893. [PMID: 31841403 DOI: 10.1109/tmi.2019.2959833] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Functional ultrasound imaging (fUS) recently emerged as a promising neuroimaging modality to image and monitor brain activity based on cerebral blood volume response (CBV) and neurovascular coupling. fUS offers very good spatial and temporal resolutions compared to fMRI gold standard as well as simplicity and portability. It was recently extended to 4D fUS imaging in preclinical settings although this approach remains limited and complex. Indeed 4D fUS requires a 2D matrix probe and specific hardware able to drive the N2 elements of the probe with thousands of electronic channels. Several under-sampling approaches are currently investigated to limit the channel count and spread ultrasound 4D modalities. Among them, the Row Column Addressing (RCA) approach combined with ultrafast imaging is a compelling alternative using only N + N channels. We present a large field of view RCA probe prototype of 128 + 128 channels and 15 MHz central frequency adapted for preclinical imaging. Based on the Orthogonal Plane Wave compounding scheme, we were able to perform 4D vascular brain acquisitions at high volume rate. Doppler volumes of the whole rat brain were obtained in vivo at high rates (23 dB CNR at 156 Hz and 19 dB CNR at 313 Hz). Visual and whiskers stimulations were performed and the corresponding CBV increases were reconstructed in 3D with successful functional activation detected in the superior colliculus and somato-sensorial cortex respectively. This proof of concept study demonstrates for the first time the use of a low-channel count RCA array for in vivo 4D fUS imaging in the whole rat brain.
Collapse
|
55
|
Zhang N, Ashikuzzaman M, Rivaz H. Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods. Biomed Eng Online 2020; 19:37. [PMID: 32466753 PMCID: PMC7254711 DOI: 10.1186/s12938-020-00778-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 05/07/2020] [Indexed: 11/10/2022] Open
Abstract
Vessel diseases are often accompanied by abnormalities related to vascular shape and size. Therefore, a clear visualization of vasculature is of high clinical significance. Ultrasound color flow imaging (CFI) is one of the prominent techniques for flow visualization. However, clutter signals originating from slow-moving tissue are one of the main obstacles to obtain a clear view of the vascular network. Enhancement of the vasculature by suppressing the clutters is a significant and irreplaceable step for many applications of ultrasound CFI. Currently, this task is often performed by singular value decomposition (SVD) of the data matrix. This approach exhibits two well-known limitations. First, the performance of SVD is sensitive to the proper manual selection of the ranks corresponding to clutter and blood subspaces. Second, SVD is prone to failure in the presence of large random noise in the dataset. A potential solution to these issues is using decomposition into low-rank and sparse matrices (DLSM) framework. SVD is one of the algorithms for solving the minimization problem under the DLSM framework. Many other algorithms under DLSM avoid full SVD and use approximated SVD or SVD-free ideas which may have better performance with higher robustness and less computing time. In practice, these models separate blood from clutter based on the assumption that steady clutter represents a low-rank structure and that the moving blood component is sparse. In this paper, we present a comprehensive review of ultrasound clutter suppression techniques and exploit the feasibility of low-rank and sparse decomposition schemes in ultrasound clutter suppression. We conduct this review study by adapting 106 DLSM algorithms and validating them against simulation, phantom, and in vivo rat datasets. Two conventional quality metrics, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), are used for performance evaluation. In addition, computation times required by different algorithms for generating clutter suppressed images are reported. Our extensive analysis shows that the DLSM framework can be successfully applied to ultrasound clutter suppression.
Collapse
Affiliation(s)
- Naiyuan Zhang
- Department of Electrical and Computer Engineering, Concordia, Rue Sainte-Catherine O, Montreal, Canada
| | - Md Ashikuzzaman
- Department of Electrical and Computer Engineering, Concordia, Rue Sainte-Catherine O, Montreal, Canada
| | - Hassan Rivaz
- Department of Electrical and Computer Engineering, Concordia, Rue Sainte-Catherine O, Montreal, Canada.
| |
Collapse
|
56
|
Solomon O, Cohen R, Zhang Y, Yang Y, He Q, Luo J, van Sloun RJG, Eldar YC. Deep Unfolded Robust PCA With Application to Clutter Suppression in Ultrasound. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:1051-1063. [PMID: 31535987 DOI: 10.1109/tmi.2019.2941271] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Contrast enhanced ultrasound is a radiation-free imaging modality which uses encapsulated gas microbubbles for improved visualization of the vascular bed deep within the tissue. It has recently been used to enable imaging with unprecedented subwavelength spatial resolution by relying on super-resolution techniques. A typical preprocessing step in super-resolution ultrasound is to separate the microbubble signal from the cluttering tissue signal. This step has a crucial impact on the final image quality. Here, we propose a new approach to clutter removal based on robust principle component analysis (PCA) and deep learning. We begin by modeling the acquired contrast enhanced ultrasound signal as a combination of low rank and sparse components. This model is used in robust PCA and was previously suggested in the context of ultrasound Doppler processing and dynamic magnetic resonance imaging. We then illustrate that an iterative algorithm based on this model exhibits improved separation of microbubble signal from the tissue signal over commonly practiced methods. Next, we apply the concept of deep unfolding to suggest a deep network architecture tailored to our clutter filtering problem which exhibits improved convergence speed and accuracy with respect to its iterative counterpart. We compare the performance of the suggested deep network on both simulations and in-vivo rat brain scans, with a commonly practiced deep-network architecture and with the fast iterative shrinkage algorithm. We show that our architecture exhibits better image quality and contrast.
Collapse
|
57
|
Sharma A, Hind K, Hume P, Singh J, Neary JP. Neurovascular Coupling by Functional Near Infra-Red Spectroscopy and Sport-Related Concussion in Retired Rugby Players: The UK Rugby Health Project. Front Hum Neurosci 2020; 14:42. [PMID: 32116616 PMCID: PMC7033387 DOI: 10.3389/fnhum.2020.00042] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 01/27/2020] [Indexed: 12/21/2022] Open
Abstract
Aim: This study investigated cerebral hemodynamic responses to a neurovascular coupling (NVC) test in retired contact athletes with a history of repeated mild traumatic brain injury (mTBI) and in controls with no history of mTBI. Methods: Twenty-one retired rugby players (47.7 ± 12.9 year old; age at retirement: 38.5 ± 8.9 year; number of years playing rugby: 12.7 ± 3.7 year) with a history of three or more diagnosed concussions (8.9 ± 7.9 concussions per player) and 23 controls with no history of mTBI (46.5 ± 12.8 year old) performed a NVC test to detect task-orientated cerebral hemodynamic changes using functional near-infrared spectroscopy (fNIRS). Results: The NVC showed a statistically significant reduction in the cerebral hemodynamic response in comparison to the control group which had a greater relative increase of oxyhemoglobin (O2Hb). There were reductions in left middle frontal gyrus (MFG) O2Hb (-0.015 ± 0.258 μM) and relative increases in deoxyhemoglobin (HHb; -0.004 ± 0.159 μM) in the same region for the mTBI group in comparison to the control group (-0.160 ± 0.311 μM; -0.121 ± 0.076 μM for O2Hb and HHb, respectively). The mTBI group induced a greater rate of oxygen extraction compared to the control group. Conclusion: This was the first study to examine cerebral hemodynamic changes in retired rugby players in response to a NVC test, and we found reduced cerebral hemodynamic responses in participants with a history of mTBI compared to controls. These results suggest altered cerebral metabolic demands in participants with a history of multiple head injuries. Further research is needed to ascertain an understanding of the changes in hemodynamics from playing into retirement.
Collapse
Affiliation(s)
| | - Karen Hind
- Department of Sport and Exercise Sciences, Durham University, Durham, United Kingdom
| | - Patria Hume
- Sports Performance Research Institute New Zealand (SPRINZ), Faculty of Health and Environmental Science, Auckland University of Technology, Auckland, New Zealand
| | - Jyotpal Singh
- Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada
| | - J. Patrick Neary
- Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada
| |
Collapse
|
58
|
Disposable ultrasound-sensing chronic cranial window by soft nanoimprinting lithography. Nat Commun 2019; 10:4277. [PMID: 31537800 PMCID: PMC6753120 DOI: 10.1038/s41467-019-12178-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 08/27/2019] [Indexed: 01/31/2023] Open
Abstract
Chronic cranial window (CCW) is an essential tool in enabling longitudinal imaging and manipulation of various brain activities in live animals. However, an active CCW capable of sensing the concealed in vivo environment while simultaneously providing longitudinal optical access to the brain is not currently available. Here we report a disposable ultrasound-sensing CCW (usCCW) featuring an integrated transparent nanophotonic ultrasonic detector fabricated using soft nanoimprint lithography process. We optimize the sensor design and the associated fabrication process to significantly improve detection sensitivity and reliability, which are critical for the intend longitudinal in vivo investigations. Surgically implanting the usCCW on the skull creates a self-contained environment, maintaining optical access while eliminating the need for external ultrasound coupling medium for photoacoustic imaging. Using this usCCW, we demonstrate photoacoustic microscopy of cortical vascular network in live mice over 28 days. This work establishes the foundation for integrating photoacoustic imaging with modern brain research. Chronic cranial windows (CCW) enable long-term imaging of brain activity, but usually they only provide passive optical access to the tissue. Here the authors develop an active CCW integrated with an ultrasound detector which enables long-term photoacoustic imaging of the cortical vasculature in live mice with higher image quality.
Collapse
|
59
|
Whole-Brain Functional Ultrasound Imaging Reveals Brain Modules for Visuomotor Integration. Neuron 2019; 100:1241-1251.e7. [PMID: 30521779 PMCID: PMC6292977 DOI: 10.1016/j.neuron.2018.11.031] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 09/05/2018] [Accepted: 11/16/2018] [Indexed: 11/22/2022]
Abstract
Large numbers of brain regions are active during behaviors. A high-resolution, brain-wide activity map could identify brain regions involved in specific behaviors. We have developed functional ultrasound imaging to record whole-brain activity in behaving mice at a resolution of ∼100 μm. We detected 87 active brain regions during visual stimulation that evoked the optokinetic reflex, a visuomotor behavior that stabilizes the gaze both horizontally and vertically. Using a genetic mouse model of congenital nystagmus incapable of generating the horizontal reflex, we identified a subset of regions whose activity was reflex dependent. By blocking eye motion in control animals, we further separated regions whose activity depended on the reflex’s motor output. Remarkably, all reflex-dependent but eye motion-independent regions were located in the thalamus. Our work identifies functional modules of brain regions involved in sensorimotor integration and provides an experimental approach to monitor whole-brain activity of mice in normal and disease states. Functional ultrasound enables imaging whole-brain activity during mouse behavior Activity in 87 brain regions are modulated during the optokinetic reflex Reflex-related regions were identified by perturbing retinal direction selectivity A subset of these regions, all in the thalamus, are independent of eye motion
Collapse
|
60
|
Merkle CW, Zhu J, Bernucci MT, Srinivasan VJ. Dynamic Contrast Optical Coherence Tomography reveals laminar microvascular hemodynamics in the mouse neocortex in vivo. Neuroimage 2019; 202:116067. [PMID: 31394180 DOI: 10.1016/j.neuroimage.2019.116067] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 07/01/2019] [Accepted: 08/01/2019] [Indexed: 12/18/2022] Open
Abstract
Studies of flow-metabolism coupling often presume that microvessel architecture is a surrogate for blood flow. To test this assumption, we introduce an in vivo Dynamic Contrast Optical Coherence Tomography (DyC-OCT) method to quantify layer-resolved microvascular blood flow and volume across the full depth of the mouse neocortex, where the angioarchitecture has been previously described. First, we cross-validate average DyC-OCT cortical flow against conventional Doppler OCT flow. Next, with laminar DyC-OCT, we discover that layer 4 consistently exhibits the highest microvascular blood flow, approximately two-fold higher than the outer cortical layers. While flow differences between layers are well-explained by microvascular volume and density, flow differences between subjects are better explained by transit time. Finally, from layer-resolved tracer enhancement, we also infer that microvascular hematocrit increases in deep cortical layers, consistent with predictions of plasma skimming. Altogether, our results show that while the cortical blood supply derives mainly from the pial surface, laminar hemodynamics ensure that the energetic needs of individual cortical layers are met. The laminar trends reported here provide data that links predictions based on the cortical angioarchitecture to cerebrovascular physiology in vivo.
Collapse
Affiliation(s)
- Conrad W Merkle
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA
| | - Jun Zhu
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA
| | - Marcel T Bernucci
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA
| | - Vivek J Srinivasan
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, USA; Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, CA, 95817, USA.
| |
Collapse
|
61
|
Jung H, Huberman AD. An Unbiased View of Neural Networks: More than Meets the Eye. Neuron 2019; 100:1019-1021. [PMID: 30521775 DOI: 10.1016/j.neuron.2018.11.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this issue of Neuron, Macé et al. (2018) use whole-brain functional ultrasound imaging in mice to unveil the circuits involved reflexive eye movements. They separated the sensory and motor networks and discovered that certain eye movements robustly suppress the amygdala.
Collapse
Affiliation(s)
- Heekyung Jung
- Department of Neurobiology, Stanford University School of Medicine, Stanford, CA 94305, USA
| | - Andrew D Huberman
- Department of Neurobiology, Stanford University School of Medicine, Stanford, CA 94305, USA; Department of Ophthalmology, Stanford University School of Medicine, Stanford, CA 94305, USA; Neurosciences Institute, Stanford University School of Medicine, Stanford, CA 94305, USA; BioX, Stanford University School of Medicine, Stanford, CA 94305, USA.
| |
Collapse
|
62
|
Chen Q, Xie H, Xi L. Wearable optical resolution photoacoustic microscopy. JOURNAL OF BIOPHOTONICS 2019; 12:e201900066. [PMID: 30989817 PMCID: PMC6688948 DOI: 10.1002/jbio.201900066] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 04/10/2019] [Accepted: 04/13/2019] [Indexed: 05/08/2023]
Abstract
Optical resolution photoacoustic microscopy (ORPAM) is an emerging imaging technique, which has been extensively used to study various brain activities and disorders of the anesthetized/restricted rodents with a special focus on the morphological and functional visualization of cerebral cortex. However, it is challenging to develop a wearable photoacoustic microscope, which enables the investigation of brain activities/disorders on freely moving rodents. Here, we report a wearable and robust optical resolution photoacoustic microscope (W-ORPAM), which utilizes a small, light, stable and fast optical scanner. This wearable imaging probe features high spatiotemporal resolution, large field of view (FOV) and easy assembly as well as adjustable optical focus during the in vivo experiment, which makes it accessible to image cerebral cortex activities of freely moving rodents. To demonstrate the advantages of this technique, we used W-ORPAM to monitor both morphological and functional variations of vasculature in cerebral cortex during the induction of ischemia and reperfusion of a freely moving rat.
Collapse
Affiliation(s)
- Qian Chen
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, China
| | - Huikai Xie
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, Florida
| | - Lei Xi
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China
| |
Collapse
|
63
|
Huang C, Song P, Gong P, Trzasko JD, Manduca A, Chen S. Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1281-1291. [PMID: 31135357 PMCID: PMC6743739 DOI: 10.1109/tuffc.2019.2918180] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Ultrasound microvessel imaging (UMI) based on the combination of singular value decomposition (SVD) clutter filtering and ultrafast plane wave imaging has recently demonstrated significantly improved Doppler sensitivity, especially to small vessels that are invisible to conventional Doppler imaging. Practical implementation of UMI is hindered by the high computational cost associated with SVD and low blood signal-to-noise ratio (SNR) in deep regions of the tissue due to the lack of transmit focusing of plane waves. Concerning the high computational cost, an accelerated SVD clutter filtering method based on randomized SVD (rSVD) and randomized spatial downsampling (rSD) was recently proposed by our group, which showed the feasibility of real-time implementation of UMI. Concerning the low blood flow SNR in deep imaging regions, here we propose a noise suppression method based on noise debiasing that can be easily applied to the accelerated SVD method to bridge the gap between real-time implementation and high imaging quality. The proposed method experimentally measures the noise-induced bias by collecting the noise signal using the identical imaging sequence as regular UMI, but with the ultrasound transmission turned off. The estimated bias can then be subtracted from the original power Doppler (PD) image to obtain effective noise suppression. The feasibility of the proposed method was validated under different ultrasound imaging parameters [including transmitting voltages and time-gain compensation (TGC) settings] with a phantom experiment. The noise-debiased images showed an increase of up to 15.3 and 13.4 dB in SNR as compared to original PD images on the blood flow phantom and an in vivo human kidney data set, respectively. The proposed noise suppression method has negligible computational cost and can be conveniently combined with the previously proposed accelerated SVD clutter filtering technique to achieve high quality, real-time UMI imaging.
Collapse
Affiliation(s)
- Chengwu Huang
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Pengfei Song
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801
| | - Ping Gong
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Joshua D. Trzasko
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| | - Armando Manduca
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN 55905 USA
| | - Shigao Chen
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905, USA
| |
Collapse
|
64
|
Kobayashi T, Islam T, Sato M, Ohkura M, Nakai J, Hayashi Y, Okamoto H. Wide and Deep Imaging of Neuronal Activities by a Wearable NeuroImager Reveals Premotor Activity in the Whole Motor Cortex. Sci Rep 2019; 9:8366. [PMID: 31182818 PMCID: PMC6557893 DOI: 10.1038/s41598-019-44146-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 05/09/2019] [Indexed: 12/04/2022] Open
Abstract
Wearable technologies for functional whole brain imaging in freely moving animals would advance our understanding of cognitive processing and adaptive behavior. Fluorescence imaging can visualize the activity of individual neurons in real time, but conventional microscopes have limited sample coverage in both the width and depth of view. Here we developed a novel head-mounted laser camera (HLC) with macro and deep-focus lenses that enable fluorescence imaging at cellular resolution for comprehensive imaging in mice expressing a layer- and cell type-specific calcium probe. We visualized orientation selectivity in individual excitatory neurons across the whole visual cortex of one hemisphere, and cell assembly expressing the premotor activity that precedes voluntary movement across the motor cortex of both hemispheres. Including options for multiplex and wireless interfaces, our wearable, wide- and deep-imaging HLC technology could enable simple and economical mapping of neuronal populations underlying cognition and behavior.
Collapse
Affiliation(s)
- Takuma Kobayashi
- Laboratory for Neural Circuit Dynamics of Decision Making, RIKEN Center for Brain Science, Wako, Saitama, 351-0198, Japan.
| | - Tanvir Islam
- Laboratory for Neural Circuit Dynamics of Decision Making, RIKEN Center for Brain Science, Wako, Saitama, 351-0198, Japan
| | - Masaaki Sato
- Graduate School of Science and Engineering, Saitama University, Wako, Saitama, 338-8570, Japan.,Brain and Body System Science Institute, Saitama University, Wako, Saitama, 338-8570, Japan.,Laboratory for Mental Biology, RIKEN Center for Brain Science, Wako, Saitama, 351-0198, Japan
| | - Masamichi Ohkura
- Graduate School of Science and Engineering, Saitama University, Wako, Saitama, 338-8570, Japan.,Brain and Body System Science Institute, Saitama University, Wako, Saitama, 338-8570, Japan
| | - Junichi Nakai
- Graduate School of Science and Engineering, Saitama University, Wako, Saitama, 338-8570, Japan.,Brain and Body System Science Institute, Saitama University, Wako, Saitama, 338-8570, Japan
| | - Yasunori Hayashi
- Brain and Body System Science Institute, Saitama University, Wako, Saitama, 338-8570, Japan.,RIKEN Center for Brain Science, Wako, Saitama, 351-0198, Japan.,Department of Pharmacology, Kyoto University Graduate School of Medicine, Kyoto, 606-8501, Japan
| | - Hitoshi Okamoto
- Laboratory for Neural Circuit Dynamics of Decision Making, RIKEN Center for Brain Science, Wako, Saitama, 351-0198, Japan.
| |
Collapse
|
65
|
Song P, Cuellar CA, Tang S, Islam R, Wen H, Huang C, Manduca A, Trzasko JD, Knudsen BE, Lee KH, Chen S, Lavrov IA. Functional Ultrasound Imaging of Spinal Cord Hemodynamic Responses to Epidural Electrical Stimulation: A Feasibility Study. Front Neurol 2019; 10:279. [PMID: 30972010 PMCID: PMC6445046 DOI: 10.3389/fneur.2019.00279] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 03/04/2019] [Indexed: 12/25/2022] Open
Abstract
This study presents the first implementation of functional ultrasound (fUS) imaging of the spinal cord to monitor local hemodynamic response to epidural electrical spinal cord stimulation (SCS) on two small and large animal models. SCS has been successfully applied to control chronic refractory pain and recently was evolved to alleviate motor impairment in Parkinson's disease and after spinal cord injury. At present, however, the mechanisms underlying SCS remain unclear, and current methods for monitoring SCS are limited in their capacity to provide the required sensitivity and spatiotemporal resolutions to evaluate functional changes in response to SCS. fUS is an emerging technology that has recently shown promising results in monitoring a variety of neural activities associated with the brain. Here we demonstrated the feasibility of performing fUS on two animal models during SCS. We showed in vivo spinal cord hemodynamic responses measured by fUS evoked by different SCS parameters. We also demonstrated that fUS has a higher sensitivity in monitoring spinal cord response than electromyography. The high spatial and temporal resolutions of fUS were demonstrated by localized measurements of hemodynamic responses at different spinal cord segments, and by reliable tracking of spinal cord responses to patterned electrical stimulations, respectively. Finally, we proposed optimized fUS imaging and post-processing methods for spinal cord. These results support feasibility of fUS imaging of the spinal cord and could pave the way for future systematic studies to investigate spinal cord functional organization and the mechanisms of spinal cord neuromodulation in vivo.
Collapse
Affiliation(s)
- Pengfei Song
- Department of Radiology, Mayo Clinic, Rochester, MN, United States
| | - Carlos A. Cuellar
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
| | - Shanshan Tang
- Department of Radiology, Mayo Clinic, Rochester, MN, United States
| | - Riazul Islam
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
| | - Hai Wen
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
| | - Chengwu Huang
- Department of Radiology, Mayo Clinic, Rochester, MN, United States
| | - Armando Manduca
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States
| | | | - Bruce E. Knudsen
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
| | - Kendall H. Lee
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, United States
| | - Shigao Chen
- Department of Radiology, Mayo Clinic, Rochester, MN, United States
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States
| | - Igor A. Lavrov
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States
- Department of Neurology, Mayo Clinic, Rochester, MN, United States
- Institute of Fundamental Medicine and Biology, Kazan Federal University, Kazan, Russia
| |
Collapse
|
66
|
Bar-Zion A, Solomon O, Tremblay-Darveau C, Adam D, Eldar YC. SUSHI: Sparsity-Based Ultrasound Super-Resolution Hemodynamic Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2365-2380. [PMID: 30295619 DOI: 10.1109/tuffc.2018.2873380] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Identifying and visualizing vasculature within organs and tumors has major implications in managing cardiovascular diseases and cancer. Contrast-enhanced ultrasound scans detect slow-flowing blood, facilitating noninvasive perfusion measurements. However, their limited spatial resolution prevents the depiction of microvascular structures. Recently, super-localization ultrasonography techniques have surpassed this limit. However, they require long acquisition times of several minutes, preventing the detection of hemodynamic changes. We present a fast super-resolution method that exploits sparsity in the underlying vasculature and statistical independence within the measured signals. Similar to super-localization techniques, this approach improves the spatial resolution by up to an order of magnitude compared to standard scans. Unlike super-localization methods, it requires acquisition times of only tens of milliseconds. We demonstrate a temporal resolution of ~25 Hz, which may enable functional super-resolution imaging deep within the tissue, surpassing the temporal resolution limitations of current super-resolution methods, e.g., in neural imaging. The subsecond acquisitions make our approach robust to motion artifacts, simplifying in vivo use of super-resolution ultrasound.
Collapse
|
67
|
Wang JB, Aryal M, Zhong Q, Vyas DB, Airan RD. Noninvasive Ultrasonic Drug Uncaging Maps Whole-Brain Functional Networks. Neuron 2018; 100:728-738.e7. [PMID: 30408444 PMCID: PMC6274638 DOI: 10.1016/j.neuron.2018.10.042] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 09/13/2018] [Accepted: 10/24/2018] [Indexed: 01/06/2023]
Abstract
Being able to noninvasively modulate brain activity, where and when an experimenter desires, with an immediate path toward human translation is a long-standing goal for neuroscience. To enable robust perturbation of brain activity while leveraging the ability of focused ultrasound to deliver energy to any point of the brain noninvasively, we have developed biocompatible and clinically translatable nanoparticles that allow ultrasound-induced uncaging of neuromodulatory drugs. Utilizing the anesthetic propofol, together with electrophysiological and imaging assays, we show that the neuromodulatory effect of ultrasonic drug uncaging is limited spatially and temporally by the size of the ultrasound focus, the sonication timing, and the pharmacokinetics of the uncaged drug. Moreover, we see secondary effects in brain regions anatomically distinct from and functionally connected to the sonicated region, indicating that ultrasonic drug uncaging could noninvasively map the changes in functional network connectivity associated with pharmacologic action at a particular brain target.
Collapse
Affiliation(s)
- Jeffrey B Wang
- Department of Radiology, Neuroradiology Division, Stanford University, Stanford, CA 94305, USA
| | - Muna Aryal
- Department of Radiology, Neuroradiology Division, Stanford University, Stanford, CA 94305, USA
| | - Qian Zhong
- Department of Radiology, Neuroradiology Division, Stanford University, Stanford, CA 94305, USA
| | - Daivik B Vyas
- Department of Radiology, Neuroradiology Division, Stanford University, Stanford, CA 94305, USA
| | - Raag D Airan
- Department of Radiology, Neuroradiology Division, Stanford University, Stanford, CA 94305, USA.
| |
Collapse
|
68
|
Brunner C, Korostelev M, Raja S, Montaldo G, Urban A, Baron JC. Evidence from functional ultrasound imaging of enhanced contralesional microvascular response to somatosensory stimulation in acute middle cerebral artery occlusion/reperfusion in rats: A marker of ultra-early network reorganization? J Cereb Blood Flow Metab 2018; 38:1690-1700. [PMID: 29972329 PMCID: PMC6168914 DOI: 10.1177/0271678x18786359] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Following middle cerebral artery (MCA) stroke, enhanced contralesional evoked responses have been consistently reported both in man and rodents as part of plastic processes thought to influence motor recovery. How early this marker of large-scale network reorganization develops has however been little addressed, yet has clinical relevance for rehabilitation strategies targeting plasticity. Previous work in mice has reported enhanced contralesional responses to unaffected-side forepaw stimulation as early as 45 min after MCA small branch occlusion. Using functional ultrasound imaging (fUSi) in anesthetized rats subjected to distal temporary MCA occlusion (MCAo), we assessed here (i) whether enhanced contralesional responses also occurred with unaffected-side whisker pad stimulation, and if so, how early after MCAo; and (ii) the time course of this abnormal response during occlusion and after reperfusion. We replicate in a more proximal MCA occlusion model the earlier findings of ultra-early enhanced contralesional evoked responses. In addition, we document this phenomenon within minutes after MCAo, and its persistence throughout the entire 90-min occlusion as well as 90-min reperfusion periods studied. These findings suggest that plastic processes may start within minutes following MCAo in rodents. If replicated in man, they might have implications regarding how early plasticity-enhancing therapies can be initiated after stroke.
Collapse
Affiliation(s)
- Clément Brunner
- 1 Inserm U894, Université Paris Descartes, Paris, France.,2 Neuro-Electronics Research Flanders (NERF; A Research Initiative by IMEC, VIB and KU Leuven), Catholic University Leuven, Leuven, Belgium
| | | | - Sushmitha Raja
- 1 Inserm U894, Université Paris Descartes, Paris, France
| | - Gabriel Montaldo
- 2 Neuro-Electronics Research Flanders (NERF; A Research Initiative by IMEC, VIB and KU Leuven), Catholic University Leuven, Leuven, Belgium
| | - Alan Urban
- 2 Neuro-Electronics Research Flanders (NERF; A Research Initiative by IMEC, VIB and KU Leuven), Catholic University Leuven, Leuven, Belgium
| | - Jean-Claude Baron
- 1 Inserm U894, Université Paris Descartes, Paris, France.,3 Department of Neurology, Hôpital Sainte-Anne, Paris, France
| |
Collapse
|
69
|
Rau R, Kruizinga P, Mastik F, Belau M, de Jong N, Bosch JG, Scheffer W, Maret G. 3D functional ultrasound imaging of pigeons. Neuroimage 2018; 183:469-477. [PMID: 30118869 DOI: 10.1016/j.neuroimage.2018.08.014] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 07/25/2018] [Accepted: 08/09/2018] [Indexed: 01/21/2023] Open
Abstract
Recent advances in ultrasound Doppler imaging have facilitated the technique of functional ultrasound (fUS) which enables visualization of brain-activity due to neurovascular coupling. As of yet, this technique has been applied to rodents as well as to human subjects during awake craniotomy surgery and human newborns. Here we demonstrate the first successful fUS studies on awake pigeons subjected to auditory and visual stimulation. To allow successful fUS on pigeons we improved the temporal resolution of fUS up to 20,000 frames per second with real-time visualization and continuous recording. We show that this gain in temporal resolution significantly increases the sensitivity for detecting small fluctuations in cerebral blood flow and volume which may reflect increased local neural activity. Through this increased sensitivity we were able to capture the elaborate 3D neural activity pattern evoked by a complex stimulation pattern, such as a moving light source. By pushing the limits of fUS further, we have reaffirmed the enormous potential of this technique as a new standard in functional brain imaging with the capacity to unravel unknown, stimulus related hemodynamics with excellent spatiotemporal resolution with a wide field of view.
Collapse
Affiliation(s)
- Richard Rau
- Department of Physics, University of Konstanz, Konstanz, Germany. http://cms.uni-konstanz.de/physik/maret/
| | - Pieter Kruizinga
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands
| | - Frits Mastik
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands
| | - Markus Belau
- Department of Physics, University of Konstanz, Konstanz, Germany
| | - Nico de Jong
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands; Laboratory of Acoustical Wavefield Imaging, Delft University of Technology, Delft, the Netherlands
| | - Johannes G Bosch
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands
| | | | - Georg Maret
- Department of Physics, University of Konstanz, Konstanz, Germany.
| |
Collapse
|
70
|
Couture O, Hingot V, Heiles B, Muleki-Seya P, Tanter M. Ultrasound Localization Microscopy and Super-Resolution: A State of the Art. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1304-1320. [PMID: 29994673 DOI: 10.1109/tuffc.2018.2850811] [Citation(s) in RCA: 134] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Because it drives the compromise between resolution and penetration, the diffraction limit has long represented an unreachable summit to conquer in ultrasound imaging. Within a few years after the introduction of optical localization microscopy, we proposed its acoustic alter ego that exploits the micrometric localization of microbubble contrast agents to reconstruct the finest vessels in the body in-depth. Various groups now working on the subject are optimizing the localization precision, microbubble separation, acquisition time, tracking, and velocimetry to improve the capacity of ultrasound localization microscopy (ULM) to detect and distinguish vessels much smaller than the wavelength. It has since been used in vivo in the brain, the kidney, and tumors. In the clinic, ULM is bound to improve drastically our vision of the microvasculature, which could revolutionize the diagnosis of cancer, arteriosclerosis, stroke, and diabetes.
Collapse
|
71
|
Bimbard C, Demene C, Girard C, Radtke-Schuller S, Shamma S, Tanter M, Boubenec Y. Multi-scale mapping along the auditory hierarchy using high-resolution functional UltraSound in the awake ferret. eLife 2018; 7:e35028. [PMID: 29952750 PMCID: PMC6039176 DOI: 10.7554/elife.35028] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Accepted: 06/16/2018] [Indexed: 12/22/2022] Open
Abstract
A major challenge in neuroscience is to longitudinally monitor whole brain activity across multiple spatial scales in the same animal. Functional UltraSound (fUS) is an emerging technology that offers images of cerebral blood volume over large brain portions. Here we show for the first time its capability to resolve the functional organization of sensory systems at multiple scales in awake animals, both within small structures by precisely mapping and differentiating sensory responses, and between structures by elucidating the connectivity scheme of top-down projections. We demonstrate that fUS provides stable (over days), yet rapid, highly-resolved 3D tonotopic maps in the auditory pathway of awake ferrets, thus revealing its unprecedented functional resolution (100/300µm). This was performed in four different brain regions, including very small (1-2 mm3 size), deeply situated subcortical (8 mm deep) and previously undescribed structures in the ferret. Furthermore, we used fUS to map long-distance projections from frontal cortex, a key source of sensory response modulation, to auditory cortex.
Collapse
Affiliation(s)
- Célian Bimbard
- Audition TeamLaboratoire des Systèmes Perceptifs CNRS UMR 8248, École Normale Supérieure, PSL Research UniversityParisFrance
| | - Charlie Demene
- Institut Langevin, ESPCI ParisTech, INSERM U979, CNRS UMR 7587, PSL Research UniversityParisFrance
| | - Constantin Girard
- Audition TeamLaboratoire des Systèmes Perceptifs CNRS UMR 8248, École Normale Supérieure, PSL Research UniversityParisFrance
| | - Susanne Radtke-Schuller
- Audition TeamLaboratoire des Systèmes Perceptifs CNRS UMR 8248, École Normale Supérieure, PSL Research UniversityParisFrance
| | - Shihab Shamma
- Audition TeamLaboratoire des Systèmes Perceptifs CNRS UMR 8248, École Normale Supérieure, PSL Research UniversityParisFrance
- Institute for Systems Research, Department of Electrical and Computer EngineeringUniversity of Maryland College ParkMarylandUnited States
| | - Mickael Tanter
- Institut Langevin, ESPCI ParisTech, INSERM U979, CNRS UMR 7587, PSL Research UniversityParisFrance
| | - Yves Boubenec
- Audition TeamLaboratoire des Systèmes Perceptifs CNRS UMR 8248, École Normale Supérieure, PSL Research UniversityParisFrance
| |
Collapse
|
72
|
Linking brain vascular physiology to hemodynamic response in ultra-high field MRI. Neuroimage 2018; 168:279-295. [DOI: 10.1016/j.neuroimage.2017.02.063] [Citation(s) in RCA: 101] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2016] [Revised: 02/20/2017] [Accepted: 02/21/2017] [Indexed: 01/05/2023] Open
|
73
|
Deffieux T, Demene C, Pernot M, Tanter M. Functional ultrasound neuroimaging: a review of the preclinical and clinical state of the art. Curr Opin Neurobiol 2018; 50:128-135. [PMID: 29477979 DOI: 10.1016/j.conb.2018.02.001] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 02/01/2018] [Accepted: 02/03/2018] [Indexed: 12/15/2022]
Abstract
In the last decade, ultrasound imaging has gained new capabilities and produced new insights in the field of neuroscience. The development of new concepts, such as ultrafast ultrasound, has enhanced Doppler sensitivity by orders of magnitude and has paved the way for ultrasonic functional neuroimaging. In this review, we position ultrasound in the field of neuroimaging and discuss how it complements current tools available to neurobiologists and clinicians.
Collapse
Affiliation(s)
- Thomas Deffieux
- Institut Langevin, CNRS, ESPCI Paris, Inserm, PSL Research University, Paris, France; Inserm Technology Research Accelerator in Biomedical Ultrasound, Paris, France
| | - Charlie Demene
- Institut Langevin, CNRS, ESPCI Paris, Inserm, PSL Research University, Paris, France; Inserm Technology Research Accelerator in Biomedical Ultrasound, Paris, France
| | - Mathieu Pernot
- Institut Langevin, CNRS, ESPCI Paris, Inserm, PSL Research University, Paris, France; Inserm Technology Research Accelerator in Biomedical Ultrasound, Paris, France
| | - Mickael Tanter
- Institut Langevin, CNRS, ESPCI Paris, Inserm, PSL Research University, Paris, France; Inserm Technology Research Accelerator in Biomedical Ultrasound, Paris, France.
| |
Collapse
|
74
|
Song P, Manduca A, Trzasko JD, Chen S. Noise Equalization for Ultrafast Plane Wave Microvessel Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1776-1781. [PMID: 28880169 PMCID: PMC5664205 DOI: 10.1109/tuffc.2017.2748387] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Ultrafast plane wave microvessel imaging significantly improves ultrasound Doppler sensitivity by increasing the number of Doppler ensembles that can be collected within a short period of time. The rich spatiotemporal plane wave data also enable more robust clutter filtering based on singular value decomposition. However, due to the lack of transmit focusing, plane wave microvessel imaging is very susceptible to noise. This paper was designed to: 1) study the relationship between ultrasound system noise (primarily time gain compensation induced) and microvessel blood flow signal and 2) propose an adaptive and computationally cost-effective noise equalization method that is independent of hardware or software imaging settings to improve microvessel image quality.
Collapse
|
75
|
Urban A, Golgher L, Brunner C, Gdalyahu A, Har-Gil H, Kain D, Montaldo G, Sironi L, Blinder P. Understanding the neurovascular unit at multiple scales: Advantages and limitations of multi-photon and functional ultrasound imaging. Adv Drug Deliv Rev 2017; 119:73-100. [PMID: 28778714 DOI: 10.1016/j.addr.2017.07.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 07/17/2017] [Accepted: 07/22/2017] [Indexed: 02/07/2023]
Abstract
Developing efficient brain imaging technologies by combining a high spatiotemporal resolution and a large penetration depth is a key step for better understanding the neurovascular interface that emerges as a main pathway to neurodegeneration in many pathologies such as dementia. This review focuses on the advances in two complementary techniques: multi-photon laser scanning microscopy (MPLSM) and functional ultrasound imaging (fUSi). MPLSM has become the gold standard for in vivo imaging of cellular dynamics and morphology, together with cerebral blood flow. fUSi is an innovative imaging modality based on Doppler ultrasound, capable of recording vascular brain activity over large scales (i.e., tens of cubic millimeters) at unprecedented spatial and temporal resolution for such volumes (up to 10μm pixel size at 10kHz). By merging these two technologies, researchers may have access to a more detailed view of the various processes taking place at the neurovascular interface. MPLSM and fUSi are also good candidates for addressing the major challenge of real-time delivery, monitoring, and in vivo evaluation of drugs in neuronal tissue.
Collapse
Affiliation(s)
- Alan Urban
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium; Department of Neurosciences, KU Leuven, Leuven, Belgium; Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Lior Golgher
- Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel
| | - Clément Brunner
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium
| | - Amos Gdalyahu
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Hagai Har-Gil
- Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel
| | - David Kain
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Gabriel Montaldo
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium
| | - Laura Sironi
- Physics Dept., Universita degli Studi di Milano Bicocca, Italy
| | - Pablo Blinder
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel; Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel.
| |
Collapse
|
76
|
Hancock AM, Frostig RD. Testing the effects of sensory stimulation as a collateral-based therapeutic for ischemic stroke in C57BL/6J and CD1 mouse strains. PLoS One 2017; 12:e0183909. [PMID: 28902897 PMCID: PMC5597132 DOI: 10.1371/journal.pone.0183909] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Accepted: 08/14/2017] [Indexed: 11/19/2022] Open
Abstract
Utilizing a rat model of ischemic stroke, we have previously shown that sensory stimulation can completely protect rats from impending ischemic damage of cortex if this treatment is delivered within the first two hours post-permanent middle cerebral artery occlusion (pMCAo). The current study sought to extend our findings in rats to mice, which would allow new avenues of research not available in rats. Thus, young adult C57BL/6J and CD1 mice were tested for protection from ischemic stroke with the same protective sensory stimulation-based treatment. Cortical activity and blood flow were assessed with intrinsic signal optical imaging (ISOI) and laser speckle imaging (LSI), respectively, and histological analysis (TTC) was performed at the completion of the experiments. Standing in stark contrast to the positive results observed in rats, in both strains we found that there were no differences between treated and untreated mice at 24 hours post-pMCAo in terms of infarct volume, negative functional imaging results, and major reduction in retrograde collateral blood flow as compared to pre-pMCAo baseline and surgical controls. Also, no differences were found between the strains in terms of theses variables. Potential reasons for the differences between rats and mice are discussed.
Collapse
Affiliation(s)
- Aneeka M. Hancock
- Department of Neurobiology and Behavior, University of California Irvine, Irvine, California, United States of America
| | - Ron D. Frostig
- Department of Neurobiology and Behavior, University of California Irvine, Irvine, California, United States of America
- Center for the Neurobiology of Learning and Memory, University of California Irvine, Irvine, California, United States of America
- Department of Biomedical Engineering, University of California Irvine, Irvine, California, United States of America
| |
Collapse
|
77
|
Tiran E, Ferrier J, Deffieux T, Gennisson JL, Pezet S, Lenkei Z, Tanter M. Transcranial Functional Ultrasound Imaging in Freely Moving Awake Mice and Anesthetized Young Rats without Contrast Agent. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1679-1689. [PMID: 28476311 PMCID: PMC5754333 DOI: 10.1016/j.ultrasmedbio.2017.03.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 03/07/2017] [Accepted: 03/20/2017] [Indexed: 05/14/2023]
Abstract
Functional ultrasound (fUS) imaging by ultrasensitive Doppler detection of blood volume was previously reported to measure adult rat brain activation and functional connectivity with unmatched spatiotemporal sampling (100 μm, 1 ms), but skull-induced attenuation of ultrasonic waves imposed skull surgery or contrast agent use. Also, fUS feasibility remains to be validated in mice, a major pre-clinical model organism. In the study described here, we performed full-depth ultrasensitive Doppler imaging and 3-D Doppler tomography of the entire mouse brain under anesthesia, non-invasively through the intact skull and skin, without contrast agents. Similar results were obtained in anesthetized young rats up to postnatal day 35, thus enabling longitudinal studies on postnatal brain development. Using a newly developed ultralight ultrasonic probe and an optimized ultrasonic sequence, we also performed minimally invasive full-transcranial fUS imaging of brain vasculature and whisker stimulation-induced barrel cortex activation in awake and freely moving mice, validating transcranial fUS for brain imaging, without anesthesia-induced bias, for behavioral studies.
Collapse
Affiliation(s)
- Elodie Tiran
- INSERM U979, Paris, France; Institut Langevin, CNRS UMR 7587, Paris, France; ESPCI Paris, Paris, France; PSL Research University, Paris, France
| | - Jérémy Ferrier
- ESPCI Paris, Paris, France; PSL Research University, Paris, France; Brain Plasticity Unit, CNRS UMR 8249, Paris, France
| | - Thomas Deffieux
- INSERM U979, Paris, France; Institut Langevin, CNRS UMR 7587, Paris, France; ESPCI Paris, Paris, France; PSL Research University, Paris, France
| | - Jean-Luc Gennisson
- INSERM U979, Paris, France; Institut Langevin, CNRS UMR 7587, Paris, France; ESPCI Paris, Paris, France; PSL Research University, Paris, France
| | - Sophie Pezet
- ESPCI Paris, Paris, France; PSL Research University, Paris, France; Brain Plasticity Unit, CNRS UMR 8249, Paris, France
| | - Zsolt Lenkei
- ESPCI Paris, Paris, France; PSL Research University, Paris, France; Brain Plasticity Unit, CNRS UMR 8249, Paris, France
| | - Mickaël Tanter
- INSERM U979, Paris, France; Institut Langevin, CNRS UMR 7587, Paris, France; ESPCI Paris, Paris, France; PSL Research University, Paris, France.
| |
Collapse
|
78
|
Njemanze PC, Kranz M, Amend M, Hauser J, Wehrl H, Brust P. Gender differences in cerebral metabolism for color processing in mice: A PET/MRI Study. PLoS One 2017; 12:e0179919. [PMID: 28723938 PMCID: PMC5516971 DOI: 10.1371/journal.pone.0179919] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 06/06/2017] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Color processing is a central component of mammalian vision. Gender-related differences of color processing revealed by non-invasive functional transcranial Doppler ultrasound suggested right hemisphere pattern for blue/yellow chromatic opponency by men, and a left hemisphere pattern by women. MATERIALS AND METHODS The present study measured the accumulation of [18F]fluorodeoxyglucose ([18F]FDG) in mouse brain using small animal positron emission tomography and magnetic resonance imaging (PET/MRI) with statistical parametric mapping (SPM) during light stimulation with blue and yellow filters compared to darkness condition. RESULTS PET revealed a reverse pattern relative to dark condition compared to previous human studies: Male mice presented with left visual cortex dominance for blue through the right eye, while female mice presented with right visual cortex dominance for blue through the left eye. We applied statistical parametric mapping (SPM) to examine gender differences in activated architectonic areas within the orbital and medial prefrontal cortex and related cortical and sub-cortical areas that lead to the striatum, medial thalamus and other brain areas. The metabolic connectivity of the orbital and medial prefrontal cortex evoked by blue stimulation spread through a wide range of brain structures implicated in viscerosensory and visceromotor systems in the left intra-hemispheric regions in male, but in the right-to-left inter-hemispheric regions in female mice. Color functional ocular dominance plasticity was noted in the right eye in male mice but in the left eye in female mice. CONCLUSIONS This study of color processing in an animal model could be applied in the study of the role of gender differences in brain disease.
Collapse
Affiliation(s)
- Philip C. Njemanze
- Chidicon Medical Center, Neurocybernetic Flow Laboratory, International Institutes of Advanced Research Training, Owerri, Imo State, Nigeria
| | - Mathias Kranz
- Helmholtz-Zentrum Dresden—Rossendorf, Institute of Radiopharmaceutical Cancer Research, Department of Neuroradiopharmaceuticals, Leipzig, Germany
| | - Mario Amend
- Eberhard Karls University Tübingen, Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Tübingen, Germany
| | - Jens Hauser
- Helmholtz-Zentrum Dresden—Rossendorf, Department of Mechanical Engineering Dresden, Germany
| | - Hans Wehrl
- Eberhard Karls University Tübingen, Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Tübingen, Germany
| | - Peter Brust
- Helmholtz-Zentrum Dresden—Rossendorf, Institute of Radiopharmaceutical Cancer Research, Department of Neuroradiopharmaceuticals, Leipzig, Germany
- * E-mail:
| |
Collapse
|
79
|
Rivnay J, Wang H, Fenno L, Deisseroth K, Malliaras GG. Next-generation probes, particles, and proteins for neural interfacing. SCIENCE ADVANCES 2017; 3:e1601649. [PMID: 28630894 PMCID: PMC5466371 DOI: 10.1126/sciadv.1601649] [Citation(s) in RCA: 224] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Accepted: 04/18/2017] [Indexed: 05/18/2023]
Abstract
Bidirectional interfacing with the nervous system enables neuroscience research, diagnosis, and therapy. This two-way communication allows us to monitor the state of the brain and its composite networks and cells as well as to influence them to treat disease or repair/restore sensory or motor function. To provide the most stable and effective interface, the tools of the trade must bridge the soft, ion-rich, and evolving nature of neural tissue with the largely rigid, static realm of microelectronics and medical instruments that allow for readout, analysis, and/or control. In this Review, we describe how the understanding of neural signaling and material-tissue interactions has fueled the expansion of the available tool set. New probe architectures and materials, nanoparticles, dyes, and designer genetically encoded proteins push the limits of recording and stimulation lifetime, localization, and specificity, blurring the boundary between living tissue and engineered tools. Understanding these approaches, their modality, and the role of cross-disciplinary development will support new neurotherapies and prostheses and provide neuroscientists and neurologists with unprecedented access to the brain.
Collapse
Affiliation(s)
- Jonathan Rivnay
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Palo Alto Research Center, Palo Alto, CA 94304, USA
- Corresponding author.
| | - Huiliang Wang
- Departments of Bioengineering and Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - Lief Fenno
- Departments of Bioengineering and Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - Karl Deisseroth
- Departments of Bioengineering and Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - George G. Malliaras
- Department of Bioelectronics, École Nationale Supérieure des Mines, CMP-EMSE, MOC, Gardanne 13541, France
| |
Collapse
|
80
|
Song P, Trzasko JD, Manduca A, Qiang B, Kadirvel R, Kallmes DF, Chen S. Accelerated Singular Value-Based Ultrasound Blood Flow Clutter Filtering With Randomized Singular Value Decomposition and Randomized Spatial Downsampling. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:706-716. [PMID: 28186887 DOI: 10.1109/tuffc.2017.2665342] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Singular value decomposition (SVD)-based ultrasound blood flow clutter filters have recently demonstrated substantial improvement in clutter rejection for ultrafast plane wave microvessel imaging, and have become the commonly used clutter filtering method for many novel ultrafast imaging applications such as functional ultrasound and super-resolution imaging. At present, however, the computational burden of SVD remains as a major hurdle for practical implementation and clinical translation of this method. To address this challenge, in the study we present two blood flow clutter filtering methods based on randomized SVD (rSVD) and randomized spatial downsampling to accelerate SVD clutter filtering with minimal compromise to the clutter filter performance. rSVD accelerates SVD computation by approximating the k largest singular values, while random downsampling accelerates both full SVD and rSVD by decomposing the original large data matrix into small matrices that can be processed in parallel. An in vitro blood flow phantom study with the presence of heavy tissue clutter showed significantly improved computational performance using the proposed methods with minimal deterioration to the clutter filter performance (less than 3-dB reduction in blood to clutter ratio, less than 0.2-cm2/s2 increase in flow mean squared error, less than 0.1-cm/s increase in the standard deviation of the vessel blood flow signal, and less than 0.3-cm/s increase in tissue clutter velocity for both full SVD and rSVD when the downsampling factor was less than 20× ). The maximum acceleration was about threefold from randomized spatial downsampling, and approximately another threefold from rSVD. An in vivo rabbit kidney perfusion study showed that rSVD provided comparable performance to full SVD in clutter rejection in vivo (maximum difference of blood to clutter ratio was less than 0.6 dB), and random downsampling provided artifact-free perfusion imaging results when combined with both full SVD and rSVD. The blood to clutter ratio was still above 10 dB with a downsampling factor of 60× . We also demonstrated real-time microvessel imaging feasibility (~40-ms processing time) by combining rSVD with random downsampling. The findings and methods presented in this paper may greatly facilitate the new area of ultrafast microvessel imaging research.
Collapse
|
81
|
Li YL, Dahl JJ. Angular coherence in ultrasound imaging: Theory and applications. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:1582. [PMID: 28372139 PMCID: PMC5390598 DOI: 10.1121/1.4976960] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The popularity of plane-wave transmits at multiple transmit angles for synthetic transmit aperture (or coherent compounding) has spawned a number of adaptations and new developments of ultrasonic imaging. However, the coherence properties of backscattered signals with plane-wave transmits at different angles are unknown and may impact a subset of these techniques. To provide a framework for the analysis of the coherence properties of such signals, this article introduces the angular coherence theory in medical ultrasound imaging. The theory indicates that the correlation function of such signals forms a Fourier transform pair with autocorrelation function of the receive aperture function. This conclusion can be considered as an extended form of the van Cittert Zernike theorem. The theory is validated with simulation and experimental results obtained on speckle targets. On the basis of the angular coherence of the backscattered wave, a new short-lag angular coherence beamformer is proposed and compared with an existing spatial-coherence-based beamformer. An application of the theory in phase shift estimation and speed of sound estimation is also presented.
Collapse
Affiliation(s)
- You Leo Li
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| | - Jeremy J Dahl
- Department of Radiology, School of Medicine, Stanford University, Stanford, California 94304, USA
| |
Collapse
|
82
|
Brunner C, Isabel C, Martin A, Dussaux C, Savoye A, Emmrich J, Montaldo G, Mas JL, Baron JC, Urban A. Mapping the dynamics of brain perfusion using functional ultrasound in a rat model of transient middle cerebral artery occlusion. J Cereb Blood Flow Metab 2017; 37:263-276. [PMID: 26721392 PMCID: PMC5363744 DOI: 10.1177/0271678x15622466] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 11/17/2015] [Accepted: 11/18/2015] [Indexed: 01/07/2023]
Abstract
Following middle cerebral artery occlusion, tissue outcome ranges from normal to infarcted depending on depth and duration of hypoperfusion as well as occurrence and efficiency of reperfusion. However, the precise time course of these changes in relation to tissue and behavioral outcome remains unsettled. To address these issues, a three-dimensional wide field-of-view and real-time quantitative functional imaging technique able to map perfusion in the rodent brain would be desirable. Here, we applied functional ultrasound imaging, a novel approach to map relative cerebral blood volume without contrast agent, in a rat model of brief proximal transient middle cerebral artery occlusion to assess perfusion in penetrating arterioles and venules acutely and over six days thanks to a thinned-skull preparation. Functional ultrasound imaging efficiently mapped the acute changes in relative cerebral blood volume during occlusion and following reperfusion with high spatial resolution (100 µm), notably documenting marked focal decreases during occlusion, and was able to chart the fine dynamics of tissue reperfusion (rate: one frame/5 s) in the individual rat. No behavioral and only mild post-mortem immunofluorescence changes were observed. Our study suggests functional ultrasound is a particularly well-adapted imaging technique to study cerebral perfusion in acute experimental stroke longitudinally from the hyper-acute up to the chronic stage in the same subject.
Collapse
Affiliation(s)
- Clément Brunner
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France.,SANOFI Research and Development, Lead Generation to Candidate Realization, Chilly-Mazarin, France
| | - Clothilde Isabel
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | - Abraham Martin
- Molecular Imaging Unit, CIC biomaGUNE, San Sebastián, Spain
| | - Clara Dussaux
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | - Anne Savoye
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | | | - Gabriel Montaldo
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | - Jean-Louis Mas
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | - Jean-Claude Baron
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| | - Alan Urban
- Stroke Research Group, Centre de Psychiatrie et Neuroscience, INSERM U894, Hôpital Sainte-Anne, Paris, France
| |
Collapse
|
83
|
Li YL, Hyun D, Abou-Elkacem L, Willmann JK, Dahl JJ. Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1878-1889. [PMID: 27824565 PMCID: PMC5154731 DOI: 10.1109/tuffc.2016.2616112] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Power Doppler (PD) imaging is a widely used technique for flow detection. Despite the wide use of Doppler ultrasound, limitations exist in the ability of Doppler ultrasound to assess slow flow in the small-diameter vasculature, such as the maternal spiral arteries and fetal villous arteries of the placenta and focal liver lesions. The sensitivity of PD in small vessel detection is limited by the low signal produced by slow flow and the noise associated with small vessels. The noise sources include electronic noise, stationary or slowly moving tissue clutter, reverberation clutter, and off-axis scattering from tissue, among others. In order to provide more sensitive detection of slow flow in small diameter vessels, a coherent flow imaging technique, termed coherent flow PD (CFPD), is characterized and evaluated with simulation, flow phantom experiment studies, and an in vivo animal small vessel detection study. CFPD imaging was introduced as a technique to detect slow blood flow. It has been demonstrated to detect slow flow below the detection threshold of conventional PD imaging using identical pulse sequences and filter parameters. In this paper, we compare CFPD with PD in the detection of blood flow in small-diameter vessels. The results from the study suggest that CFPD is able to provide a 7.5-12.5-dB increase in the signal-to-noise ratio (SNR) over PD images for the same physiological conditions and is less susceptible to reverberation clutter and thermal noise. Due to the increase in SNR, CFPD is able to detect small vessels in high channel noise cases, for which PD was unable to generate enough contrast to observe the vessel.
Collapse
|
84
|
Abstract
PURPOSE OF REVIEW This article provides an overview of the recent literature regarding the application of in-vivo brain imaging techniques to animal models of ischemic stroke. RECENT FINDINGS Major breakthroughs concerned the effects of sensory stimulation on neuronal function, local hemodynamics, and tissue outcome in the hyperacute phase of stroke; the novel application to stroke of hybrid scanners allowing simultaneous PET and magnetic resonance; the refinements of magnetic resonance-based oxygen imaging, allowing to map the ischemic penumbra in a completely noninvasive way; the implementation of new PET ligands to selectively map poststroke neuronal death and neuroinflammation; and the use of novel mesoscale imaging techniques to demonstrate the major role of interhemispheric connectivity in poststroke plasticity and functional recovery. SUMMARY The array of techniques to map in vivo the key pathophysiological brain processes involved in stroke is currently enlarging at an amazing pace. This is paralleled by ever-increasing sophistication in postprocessing tools. The combination of techniques allowing simultaneous access to several variables is particularly powerful as it affords unprecedented insights into the intimate processes underlying the tissue and neuronal changes that follow a stroke. These major leaps forward will hopefully lead to therapeutic breakthroughs aiming at improving functional outcome after stroke.
Collapse
|
85
|
Limnuson K, Narayan RK, Chiluwal A, Golanov EV, Bouton CE, Li C. A User-Configurable Headstage for Multimodality Neuromonitoring in Freely Moving Rats. Front Neurosci 2016; 10:382. [PMID: 27594826 PMCID: PMC4990626 DOI: 10.3389/fnins.2016.00382] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2016] [Accepted: 08/05/2016] [Indexed: 11/21/2022] Open
Abstract
Multimodal monitoring of brain activity, physiology, and neurochemistry is an important approach to gain insight into brain function, modulation, and pathology. With recent progress in micro- and nanotechnology, micro-nano-implants have become important catalysts in advancing brain research. However, to date, only a limited number of brain parameters have been measured simultaneously in awake animals in spite of significant recent progress in sensor technology. Here we have provided a cost and time effective approach to designing a headstage to conduct a multimodality brain monitoring in freely moving animals. To demonstrate this method, we have designed a user-configurable headstage for our micromachined multimodal neural probe. The headstage can reliably record direct-current electrocorticography (DC-ECoG), brain oxygen tension (PbrO2), cortical temperature, and regional cerebral blood flow (rCBF) simultaneously without significant signal crosstalk or movement artifacts for 72 h. Even in a noisy environment, it can record low-level neural signals with high quality. Moreover, it can easily interface with signal conditioning circuits that have high power consumption and are difficult to miniaturize. To the best of our knowledge, this is the first time where multiple physiological, biochemical, and electrophysiological cerebral variables have been simultaneously recorded from freely moving rats. We anticipate that the developed system will aid in gaining further insight into not only normal cerebral functioning but also pathophysiology of conditions such as epilepsy, stroke, and traumatic brain injury.
Collapse
Affiliation(s)
- Kanokwan Limnuson
- Cushing Neuromonitoring Laboratory, The Feinstein Institute for Medical Research Manhasset, NY, USA
| | - Raj K Narayan
- Cushing Neuromonitoring Laboratory, The Feinstein Institute for Medical ResearchManhasset, NY, USA; Department of Neurosurgery, Hofstra Northwell School of MedicineHempstead, NY, USA
| | - Amrit Chiluwal
- Department of Neurosurgery, Hofstra Northwell School of Medicine Hempstead, NY, USA
| | - Eugene V Golanov
- Cushing Neuromonitoring Laboratory, The Feinstein Institute for Medical Research Manhasset, NY, USA
| | - Chad E Bouton
- Center for Bioelectronic Medicine, The Feinstein Institute for Medical Research Manhasset, NY, USA
| | - Chunyan Li
- Cushing Neuromonitoring Laboratory, The Feinstein Institute for Medical ResearchManhasset, NY, USA; Department of Neurosurgery, Hofstra Northwell School of MedicineHempstead, NY, USA; Center for Bioelectronic Medicine, The Feinstein Institute for Medical ResearchManhasset, NY, USA
| |
Collapse
|
86
|
Murphy TH, Boyd JD, Bolaños F, Vanni MP, Silasi G, Haupt D, LeDue JM. High-throughput automated home-cage mesoscopic functional imaging of mouse cortex. Nat Commun 2016; 7:11611. [PMID: 27291514 PMCID: PMC4909937 DOI: 10.1038/ncomms11611] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Accepted: 04/12/2016] [Indexed: 12/14/2022] Open
Abstract
Mouse head-fixed behaviour coupled with functional imaging has become a powerful technique in rodent systems neuroscience. However, training mice can be time consuming and is potentially stressful for animals. Here we report a fully automated, open source, self-initiated head-fixation system for mesoscopic functional imaging in mice. The system supports five mice at a time and requires minimal investigator intervention. Using genetically encoded calcium indicator transgenic mice, we longitudinally monitor cortical functional connectivity up to 24 h per day in >7,000 self-initiated and unsupervised imaging sessions up to 90 days. The procedure provides robust assessment of functional cortical maps on the basis of both spontaneous activity and brief sensory stimuli such as light flashes. The approach is scalable to a number of remotely controlled cages that can be assessed within the controlled conditions of dedicated animal facilities. We anticipate that home-cage brain imaging will permit flexible and chronic assessment of mesoscale cortical function. Functional imaging in awake head-fixed mice is a widely used technique to study neural responses. Here the authors report on an open source, fully automated unsupervised system for training mice to self initiate head fixation to enable stable mesoscopic functional imaging of cortical functional connectivity.
Collapse
Affiliation(s)
- Timothy H Murphy
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Jamie D Boyd
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Federico Bolaños
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Matthieu P Vanni
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Gergely Silasi
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Dirk Haupt
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| | - Jeff M LeDue
- Department of Psychiatry, Kinsmen Laboratory of Neurological Research, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3.,Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z3
| |
Collapse
|
87
|
Tang J, Dai X, Jiang H. Wearable scanning photoacoustic brain imaging in behaving rats. JOURNAL OF BIOPHOTONICS 2016; 9:570-575. [PMID: 26777064 DOI: 10.1002/jbio.201500311] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2015] [Revised: 12/29/2015] [Accepted: 12/30/2015] [Indexed: 06/05/2023]
Abstract
A wearable scanning photoacoustic imaging (wPAI) system is presented for noninvasive brain study in behaving rats. This miniaturized wPAI system consists of four pico linear servos and a single transducer-based PAI probe. It has a dimension of 50 mm × 35 mm × 40 mm, and a weight of 26 g excluding cablings. Phantom evaluation shows that wPAI achieves a lateral resolution of ∼0.5 mm and an axial resolution of ∼0.1 mm at a depth of up to 11 mm. Its imaging ability is also tested in a behaving rat, and the results indicate that wPAI is able to image blood vessels at a depth of up to 5 mm with intact scalp and skull. With its noninvasive, deep penetration, and functional imaging ability in behaving animals, wPAI can be used for behavior, cognition, and preclinical brain disease studies.
Collapse
Affiliation(s)
- Jianbo Tang
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Xianjin Dai
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Huabei Jiang
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA.
| |
Collapse
|
88
|
Demené C, Tiran E, Sieu LA, Bergel A, Gennisson JL, Pernot M, Deffieux T, Cohen I, Tanter M. 4D microvascular imaging based on ultrafast Doppler tomography. Neuroimage 2016; 127:472-483. [DOI: 10.1016/j.neuroimage.2015.11.014] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Revised: 11/03/2015] [Accepted: 11/04/2015] [Indexed: 12/21/2022] Open
|