201
|
Zhao B, Haldar JP, Liao C, Ma D, Jiang Y, Griswold MA, Setsompop K, Wald LL. Optimal Experiment Design for Magnetic Resonance Fingerprinting: Cramér-Rao Bound Meets Spin Dynamics. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:844-861. [PMID: 30295618 PMCID: PMC6447464 DOI: 10.1109/tmi.2018.2873704] [Citation(s) in RCA: 83] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Magnetic resonance (MR) fingerprinting is a new quantitative imaging paradigm, which simultaneously acquires multiple MR tissue parameter maps in a single experiment. In this paper, we present an estimation-theoretic framework to perform experiment design for MR fingerprinting. Specifically, we describe a discrete-time dynamic system to model spin dynamics, and derive an estimation-theoretic bound, i.e., the Cramér-Rao bound, to characterize the signal-to-noise ratio (SNR) efficiency of an MR fingerprinting experiment. We then formulate an optimal experiment design problem, which determines a sequence of acquisition parameters to encode MR tissue parameters with the maximal SNR efficiency, while respecting the physical constraints and other constraints from the image decoding/reconstruction process. We evaluate the performance of the proposed approach with numerical simulations, phantom experiments, and in vivo experiments. We demonstrate that the optimized experiments substantially reduce data acquisition time and/or improve parameter estimation. For example, the optimized experiments achieve about a factor of two improvement in the accuracy of T2 maps, while keeping similar or slightly better accuracy of T1 maps. Finally, as a remarkable observation, we find that the sequence of optimized acquisition parameters appears to be highly structured rather than randomly/pseudo-randomly varying as is prescribed in the conventional MR fingerprinting experiments.
Collapse
Affiliation(s)
- Bo Zhao
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA 02115 USA
| | - Justin P. Haldar
- Signal and Image Processing Institute and Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, CA 90089 USA
| | - Congyu Liao
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129 USA
- Department of Biomedical Engineering, Zhejiang University, Hangzhou, Zhejiang Province 310027 China
| | - Dan Ma
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Yun Jiang
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Mark A. Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Kawin Setsompop
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA, 02115 USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Lawrence L. Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA, 02115 USA, and also with the Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| |
Collapse
|
202
|
Roccia E, Vidya Shankar R, Neji R, Cruz G, Munoz C, Botnar R, Goh V, Prieto C, Dregely I. Accelerated 3D T 2 mapping with dictionary-based matching for prostate imaging. Magn Reson Med 2019; 81:1795-1805. [PMID: 30368900 DOI: 10.1002/mrm.27540] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/28/2018] [Accepted: 08/28/2018] [Indexed: 01/17/2023]
Abstract
PURPOSE To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS 3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisition sequence using a 3D variable density undersampled Cartesian trajectory. Each T2 -weighted image was reconstructed using total variation regularized sensitivity encoding. A flexible simulation framework based on extended phase graphs generated a dictionary of magnetization signals, which was customized to the proposed sequence. The dictionary was matched to the acquired T2 -weighted images to retrieve quantitative T2 values, which were then compared to gold-standard spin echo acquisition values using monoexponential fitting. The proposed approach was validated in simulations and a T1 /T2 phantom, and feasibility was tested in 8 healthy subjects. RESULTS The simulation analysis showed that the proposed T2 mapping approach is robust to noise and typically observed T1 variations. T2 values obtained in the phantom with T2 prep-bSSFP and the acquisition-specific, dictionary-based matching were highly correlated with the gold-standard spin echo method (r = 0.99). Furthermore, no differences were observed with the accelerated acquisition compared to the fully sampled acquisition (r = 0.99). T2 values obtained in prostate peripheral zone, central gland, and muscle in healthy subjects (age, 26 ± 6 years) were 97 ± 14, 76 ± 7, and 36 ± 3 ms, respectively. CONCLUSION 3D quantitative T2 mapping of the whole prostate can be achieved in 3 minutes.
Collapse
Affiliation(s)
- Elisa Roccia
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Rohini Vidya Shankar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Siemens Healthcare Limited, Frimley, United Kingdom
| | - Gastão Cruz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - René Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Vicky Goh
- Cancer Imaging, King's College London, London, United Kingdom
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Isabel Dregely
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
203
|
Frost R, Wighton P, Karahanoğlu FI, Robertson RL, Grant PE, Fischl B, Tisdall MD, van der Kouwe A. Markerless high-frequency prospective motion correction for neuroanatomical MRI. Magn Reson Med 2019; 82:126-144. [PMID: 30821010 DOI: 10.1002/mrm.27705] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 01/09/2019] [Accepted: 01/30/2019] [Indexed: 11/07/2022]
Abstract
PURPOSE To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the face, was used to adapt the imaging FOV based on head movement during MPRAGE and T2 SPACE (3D variable flip-angle turbo spin-echo) sequences. The FOV position and orientation were updated every 6 lines of k-space (< 50 ms) to enable "within-echo-train" prospective motion correction (PMC). Comparisons were made with scans using "before-echo-train" PMC, in which the FOV was updated only once per TR, before the start of each echo train (ET). Continuous-motion experiments with phantoms and in vivo were used to compare these high-frequency and low-frequency correction strategies. MPRAGE images were processed with FreeSurfer to compare estimates of brain structure volumes and cortical thickness in scans with different PMC. RESULTS The median absolute pose differences between markerless tracking and MR image registration were 0.07/0.26/0.15 mm for x/y/z translation and 0.06º/0.02º/0.12° for rotation about x/y/z. The PMC with markerless tracking substantially reduced motion artifacts. The continuous-motion experiments showed that within-ET PMC, which minimizes FOV encoding errors during ETs that last over 1 second, reduces artifacts compared with before-ET PMC. T2 SPACE was found to be more sensitive to motion during ETs than MPRAGE. FreeSurfer morphometry estimates from within-ET PMC MPRAGE images were the most accurate. CONCLUSION Markerless head tracking can be used for PMC, and high-frequency within-ET PMC can reduce sensitivity to motion during long imaging ETs.
Collapse
Affiliation(s)
- Robert Frost
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Paul Wighton
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
| | - F Işık Karahanoğlu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Richard L Robertson
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
| | - P Ellen Grant
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.,Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Boston, Massachusetts
| | - Bruce Fischl
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts.,Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - M Dylan Tisdall
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - André van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
204
|
Lima da Cruz G, Bustin A, Jaubert O, Schneider T, Botnar RM, Prieto C. Sparsity and locally low rank regularization for MR fingerprinting. Magn Reson Med 2019; 81:3530-3543. [PMID: 30720209 PMCID: PMC6492150 DOI: 10.1002/mrm.27665] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Revised: 12/03/2018] [Accepted: 12/29/2018] [Indexed: 12/22/2022]
Abstract
Purpose Develop a sparse and locally low rank (LLR) regularized reconstruction to accelerate MR fingerprinting (MRF). Methods Recent works have introduced low rank reconstructions to MRF, based on temporal compression operators learned from the MRF dictionary. In other MR applications, LLR regularization has been introduced to exploit temporal redundancy in local regions of the image. Here, we propose to include spatial sparsity and LLR regularization terms in the MRF reconstruction. This approach, so called SLLR‐MRF, further reduces aliasing in the time‐point images and enables higher acceleration factors. The proposed approach was evaluated in simulations, T1/T2 phantom acquisition, and in vivo brain acquisitions in 5 healthy subjects with different undersampling factors. Acceleration was also used in vivo to enable acquisitions with higher in‐plane spatial resolution in comparable scan time. Results Simulations, phantom, and in vivo results show that low rank MRF reconstructions with high acceleration factors (<875 time‐point images, 1 radial spoke per time‐point) have residual aliasing artifacts that propagate into the parametric maps. The artifacts are reduced with the proposed SLLR‐MRF resulting in considerable improvements in precision, without changes in accuracy. In vivo results show improved parametric maps for the proposed SLLR‐MRF, potentially enabling MRF acquisitions with 1 radial spoke per time‐point in approximately 2.6 s (~600 time‐point images) for 2 × 2 mm and 9.6 s (1750 time‐point images) for 1 × 1 mm in‐plane resolution. Conclusion The proposed SLLR‐MRF reconstruction further improves parametric map quality compared with low rank MRF, enabling shorter scan times and/or increased spatial resolution.
Collapse
Affiliation(s)
- Gastão Lima da Cruz
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| | - Aurélien Bustin
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| | - Oliver Jaubert
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| | | | - René M Botnar
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom.,Pontificia Universidad Católica de Chile, Escuela de Ingeniería, Santiago, Chile
| | - Claudia Prieto
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| |
Collapse
|
205
|
Cruz G, Jaubert O, Schneider T, Botnar RM, Prieto C. Rigid motion-corrected magnetic resonance fingerprinting. Magn Reson Med 2019; 81:947-961. [PMID: 30229558 PMCID: PMC6519164 DOI: 10.1002/mrm.27448] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 06/06/2018] [Accepted: 06/13/2018] [Indexed: 12/30/2022]
Abstract
PURPOSE Develop a method for rigid body motion-corrected magnetic resonance fingerprinting (MRF). METHODS MRF has shown some robustness to abrupt motion toward the end of the acquisition. Here, we study the effects of different types of rigid body motion during the acquisition on MRF and propose a novel approach to correct for this motion. The proposed method (MC-MRF) follows 4 steps: (1) sliding window reconstruction is performed to produce high-quality auxiliary dynamic images; (2) rotation and translation motion is estimated from the dynamic images by image registration; (3) estimated motion is used to correct acquired k-space data with corresponding rotations and phase shifts; and (4) motion-corrected data are reconstructed with low-rank inversion. MC-MRF was validated in a standard T1 /T2 phantom and 2D in vivo brain acquisitions in 7 healthy subjects. Additionally, the effect of through-plane motion in 2D MC-MRF was investigated. RESULTS Simulation results show that motion in MRF can introduce artifacts in T1 and T2 maps, depending when it occurs. MC-MRF improved parametric map quality in all phantom and in vivo experiments with in-plane motion, comparable to the no-motion ground truth. Reduced parametric map quality, even after motion correction, was observed for acquisitions with through-plane motion, particularly for smaller structures in T2 maps. CONCLUSION Here, a novel method for motion correction in MRF (MC-MRF) is proposed, which improves parametric map quality and accuracy in comparison to no-motion correction approaches. Future work will include validation of 3D MC-MRF to enable also through-plane motion correction.
Collapse
Affiliation(s)
- Gastão Cruz
- King’s College London, School of Biomedical Engineering and Imaging SciencesLondonUnited Kingdom
| | - Olivier Jaubert
- King’s College London, School of Biomedical Engineering and Imaging SciencesLondonUnited Kingdom
| | | | - Rene M. Botnar
- King’s College London, School of Biomedical Engineering and Imaging SciencesLondonUnited Kingdom
- Pontificia Universidad Católica de Chile, Escuela de IngenieríaSantiagoChile
| | - Claudia Prieto
- King’s College London, School of Biomedical Engineering and Imaging SciencesLondonUnited Kingdom
- Pontificia Universidad Católica de Chile, Escuela de IngenieríaSantiagoChile
| |
Collapse
|
206
|
Cloos MA, Assländer J, Abbas B, Fishbaugh J, Babb JS, Gerig G, Lattanzi R. Rapid Radial T 1 and T 2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting. J Magn Reson Imaging 2018; 50:810-815. [PMID: 30584691 DOI: 10.1002/jmri.26615] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 11/21/2018] [Accepted: 11/21/2018] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Quantitative MRI can detect early changes in cartilage biochemical components, but its routine clinical implementation is challenging. PURPOSE To introduce a novel technique to measure T1 and T2 along radial sections of the hip for accurate and reproducible multiparametric quantitative cartilage assessment in a clinically feasible scan time. STUDY TYPE Reproducibility, technical validation. SUBJECTS/PHANTOM A seven-compartment phantom and three healthy volunteers. FIELD STRENGTH/SEQUENCE A novel MR pulse sequence that simultaneously measures proton density (PD), T1 , and T2 at 3 T was developed. Automatic positioning and semiautomatic cartilage segmentation were implemented to improve consistency and simplify workflow. ASSESSMENT Intra- and interscanner variability of our technique was assessed over multiple scans on three different MR scanners. STATISTICAL TESTS For each scan, the median of cartilage T1 and T2 over six radial slices was calculated. Restricted maximum likelihood estimation of variance components was used to estimate intrasubject variances reflecting variation between results from the two scans using the same scanner (intrascanner variance) and variation among results from the three scanners (interscanner variance). RESULTS The estimation error for T1 and T2 with respect to reference standard measurements was less than 3% on average for the phantom. The average interscanner coefficient of variation was 1.5% (1.2-1.9%) and 0.9% (0.0-3.7%) for T1 and T2 , respectively, in the seven compartments of the phantom. Total scan time in vivo was 7:13 minutes to obtain PD, T1 , and T2 maps along six radial hip sections at 0.6 × 0.6 × 4.0 mm3 voxel resolution. Interscanner variability for the in vivo study was 1.99% and 5.46% for T1 and T2 , respectively. in vivo intrascanner variability was 1.15% for T1 and 3.24% for T2 . DATA CONCLUSION Our method, which includes slice positioning, model-based parameter estimation, and cartilage segmentation, is highly reproducible. It could enable employing quantitative hip cartilage evaluation for longitudinal and multicenter studies. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:810-815.
Collapse
Affiliation(s)
- Martijn A Cloos
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
- Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Jakob Assländer
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Batool Abbas
- Visualization, Imaging and Data Analysis (VIDA), New York University Tandon School of Engineering, Brooklyn, New York, USA
| | - James Fishbaugh
- Visualization, Imaging and Data Analysis (VIDA), New York University Tandon School of Engineering, Brooklyn, New York, USA
| | - James S Babb
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Guido Gerig
- Visualization, Imaging and Data Analysis (VIDA), New York University Tandon School of Engineering, Brooklyn, New York, USA
| | - Riccardo Lattanzi
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
- Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| |
Collapse
|
207
|
Cencini M, Biagi L, Kaggie JD, Schulte RF, Tosetti M, Buonincontri G. Magnetic resonance fingerprinting with dictionary-based fat and water separation (DBFW MRF): A multi-component approach. Magn Reson Med 2018; 81:3032-3045. [PMID: 30578569 PMCID: PMC6590362 DOI: 10.1002/mrm.27628] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 10/04/2018] [Accepted: 11/14/2018] [Indexed: 12/20/2022]
Abstract
Purpose To obtain a fast and robust fat‐water separation with simultaneous estimation of water T1, fat T1, and fat fraction maps. Methods We modified an MR fingerprinting (MRF) framework to use a single dictionary combination of a water and fat dictionary. A variable TE acquisition pattern with maximum TE = 4.8 ms was used to increase the fat–water separability. Radiofrequency (RF) spoiling was used to reduce the size of the dictionary by reducing T2 sensitivity. The technique was compared both in vitro and in vivo to an MRF method that incorporated 3‐point Dixon (DIXON MRF), as well as Cartesian IDEAL with different acquisition parameters. Results The proposed dictionary‐based fat–water separation technique (DBFW MRF) successfully provided fat fraction, water, and fat T1, B0, and B1+ maps both in vitro and in vivo. The fat fraction and water T1 values obtained with DBFW MRF show excellent agreement with DIXON MRF as well as with the reference values obtained using a Cartesian IDEAL with a long TR (concordance correlation coefficient: 0.97/0.99 for fat fraction–water T1). Whereas fat fraction values with Cartesian IDEAL were degraded in the presence of T1 saturation, MRF methods successfully estimated and accounted for T1 in the fat fraction estimates. Conclusion The DBFW MRF technique can successfully provide T1 and fat fraction quantification in under 20 s per slice, intrinsically correcting T1 biases typical of fast Dixon techniques. These features could improve the diagnostic quality and use of images in presence of fat.
Collapse
Affiliation(s)
- Matteo Cencini
- Department of Physics, University of Pisa, Pisa, Italy.,IMAGO7 Foundation, Pisa, Italy
| | - Laura Biagi
- IMAGO7 Foundation, Pisa, Italy.,IRCCS Stella Maris Scientific Institute, Pisa, Italy
| | - Joshua D Kaggie
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom
| | | | - Michela Tosetti
- IMAGO7 Foundation, Pisa, Italy.,IRCCS Stella Maris Scientific Institute, Pisa, Italy
| | - Guido Buonincontri
- IMAGO7 Foundation, Pisa, Italy.,Istituto Nazionale di Fisica Nucleare (INFN), Pisa, Italy
| |
Collapse
|
208
|
Duan C, Zhu Y, Jang J, Rodriguez J, Neisius U, Fahmy AS, Nezafat R. Non-contrast myocardial infarct scar assessment using a hybrid native T 1 and magnetization transfer imaging sequence at 1.5T. Magn Reson Med 2018; 81:3192-3201. [PMID: 30565296 DOI: 10.1002/mrm.27636] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 11/19/2018] [Accepted: 11/20/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction. METHODS A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine. RESULTS Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01). CONCLUSION The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.
Collapse
Affiliation(s)
- Chong Duan
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Yanjie Zhu
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts.,Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jihye Jang
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts.,Department of Computer Science, Technical University of Munich, Munich, Germany
| | - Jennifer Rodriguez
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Ulf Neisius
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Ahmed S Fahmy
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
209
|
Yu Z, Zhao T, Assländer J, Lattanzi R, Sodickson DK, Cloos MA. Exploring the sensitivity of magnetic resonance fingerprinting to motion. Magn Reson Imaging 2018; 54:241-248. [PMID: 30193953 PMCID: PMC6215476 DOI: 10.1016/j.mri.2018.09.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 09/01/2018] [Accepted: 09/04/2018] [Indexed: 11/19/2022]
Abstract
PURPOSE To explore the motion sensitivity of magnetic resonance fingerprinting (MRF), we performed experiments with different types of motion at various time intervals during multiple scans. Additionally, we investigated the possibility to correct the motion artifacts based on redundancy in MRF data. METHODS A radial version of the FISP-MRF sequence was used to acquire one transverse slice through the brain. Three subjects were instructed to move in different patterns (in-plane rotation, through-plane wiggle, complex movements, adjust head position, and pretend itch) during different time intervals. The potential to correct motion artifacts in MRF by removing motion-corrupted data points from the fingerprints and dictionary was evaluated. RESULTS Morphological structures were well preserved in multi-parametric maps despite subject motion. Although the bulk T1 values were not significantly affected by motion, fine structures were blurred when in-plane motion was present during the first part of the scan. On the other hand, T2 values showed a considerable deviation from the motion-free results, especially when through-plane motion was present in the middle of the scan (-44% on average). Explicitly removing the motion-corrupted data from the scan partially restored the T2 values (-10% on average). CONCLUSION Our experimental results showed that different kinds of motion have distinct effects on the precision and effective resolution of the parametric maps measured with MRF. Although MRF-based acquisitions can be relatively robust to motion effects occurring at the beginning or end of the sequence, relying on redundancy in the data alone is not sufficient to assure the accuracy of the multi-parametric maps in all cases.
Collapse
Affiliation(s)
- Zidan Yu
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA; Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA; The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, USA.
| | - Tiejun Zhao
- Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA; Siemens Medical Solutions USA Inc., 40 Liberty Boulevard, Malvern, PA 19355, USA
| | - Jakob Assländer
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA; Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Riccardo Lattanzi
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA; Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA; The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, USA
| | - Daniel K Sodickson
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA; Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA; The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, USA
| | - Martijn A Cloos
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA; Center for Advanced Imaging Innovation and Research (CAI(2)R), Department of Radiology, New York University School of Medicine, New York, NY, USA; The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, USA
| |
Collapse
|
210
|
Henningsson M, Zahr RA, Dyer A, Greil GF, Burkhardt B, Tandon A, Hussain T. Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease. J Cardiovasc Magn Reson 2018; 20:76. [PMID: 30474554 PMCID: PMC6260764 DOI: 10.1186/s12968-018-0508-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 11/14/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.
Collapse
Affiliation(s)
- Markus Henningsson
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Riad Abou Zahr
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Adrian Dyer
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Gerald F. Greil
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Barbara Burkhardt
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Animesh Tandon
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Tarique Hussain
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| |
Collapse
|
211
|
Koolstra K, Beenakker JWM, Koken P, Webb A, Börnert P. Cartesian MR fingerprinting in the eye at 7T using compressed sensing and matrix completion-based reconstructions. Magn Reson Med 2018; 81:2551-2565. [PMID: 30421448 PMCID: PMC6519255 DOI: 10.1002/mrm.27594] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 10/09/2018] [Accepted: 10/12/2018] [Indexed: 12/14/2022]
Abstract
PURPOSE To explore the feasibility of MR Fingerprinting (MRF) to rapidly quantify relaxation times in the human eye at 7T, and to provide a data acquisition and processing framework for future tissue characterization in eye tumor patients. METHODS In this single-element receive coil MRF approach with Cartesian sampling, undersampling is used to shorten scan time and, therefore, to reduce the degree of motion artifacts. For reconstruction, approaches based on compressed sensing (CS) and matrix completion (MC) were used, while their effects on the quality of the MRF parameter maps were studied in simulations and experiments. Average relaxation times in the eye were measured in 6 healthy volunteers. One uveal melanoma patient was included to show the feasibility of MRF in a clinical context. RESULTS Simulation results showed that an MC-based reconstruction enables large undersampling factors and also results in more accurate parameter maps compared with using CS. Experiments in 6 healthy volunteers used a reduction in scan time from 7:02 to 1:16 min, producing images without visible loss of detail in the parameter maps when using the MC-based reconstruction. Relaxation times from 6 healthy volunteers are in agreement with values obtained from fully sampled scans and values in literature, and parameter maps in a uveal melanoma patient show clear difference in relaxation times between tumor and healthy tissue. CONCLUSION Cartesian-based MRF is feasible in the eye at 7T. High undersampling factors can be achieved by means of MC, significantly shortening scan time and increasing patient comfort, while also mitigating the risk of motion artifacts.
Collapse
Affiliation(s)
- Kirsten Koolstra
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands
| | - Jan-Willem Maria Beenakker
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.,Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Andrew Webb
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter Börnert
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.,Philips Research, Hamburg, Germany
| |
Collapse
|
212
|
Rigid motion correction for magnetic resonance fingerprinting with sliding-window reconstruction and image registration. Magn Reson Imaging 2018; 57:303-312. [PMID: 30439513 DOI: 10.1016/j.mri.2018.11.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 10/08/2018] [Accepted: 11/11/2018] [Indexed: 11/23/2022]
Abstract
Magnetic resonance fingerprinting (MRF) can be used to simultaneously obtain multiple parameter maps from a single pulse sequence. However, patient motion during MRF acquisition may result in blurring and artifacts in estimated parameter maps. In this work, a novel motion correction method was proposed to correct for rigid motion in MRF. The proposed method involved sliding-window reconstruction to obtain intermediate images followed by image registration to estimate rigid motion information between these images. Finally, the motion-corrupted k-space data were corrected with the estimated motion parameters and then reconstructed to obtain the parameter maps via the conventional MRF processing pipeline. The proposed method was evaluated using both simulations and in vivo MRF experiments with intently different types of motion. For motion-corrupted data, the proposed method yielded brain T1, T2 and proton density maps with obviously reduced blurring and artifacts and lower normalized root-mean-square error, compared to MRF without motion correction. In conclusion, motion-corrected MRF using the proposed method has the potential to produce accurate parameter maps in the presence of in-plane rigid motion.
Collapse
|
213
|
Roeloffs V, Rosenzweig S, Holme HCM, Uecker M, Frahm J. Frequency-modulated SSFP with radial sampling and subspace reconstruction: A time-efficient alternative to phase-cycled bSSFP. Magn Reson Med 2018; 81:1566-1579. [PMID: 30357904 DOI: 10.1002/mrm.27505] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 07/05/2018] [Accepted: 08/03/2018] [Indexed: 11/11/2022]
Abstract
PURPOSE A novel subspace-based reconstruction method for frequency-modulated balanced steady-state free precession (fmSSFP) MRI is presented. In this work, suitable data acquisition schemes, subspace sizes, and efficiencies for banding removal are investigated. THEORY AND METHODS By combining a fmSSFP MRI sequence with a 3D stack-of-stars trajectory, scan efficiency is maximized as spectral information is obtained without intermediate preparation phases. A memory-efficient reconstruction routine is implemented by introducing the low-frequency Fourier transform as a subspace which allows for the formulation of a convex reconstruction problem. The removal of banding artifacts is investigated by comparing the proposed acquisition and reconstruction technique to phase-cycled bSSFP MRI. Aliasing properties of different undersampling schemes are analyzed and water/fat separation is demonstrated by reweighting the reconstructed subspace coefficients to generate virtual spectral responses in a post-processing step. RESULTS A simple root-of-sum-of-squares combination of the reconstructed subspace coefficients yields high-SNR images with the characteristic bSSFP contrast but without banding artifacts. Compared to Golden-Angle trajectories, turn-based sampling schemes were superior in minimizing aliasing across reconstructed subspace coefficients. Water/fat separated images of the human knee were obtained by reweighting subspace coefficients. CONCLUSIONS The novel subspace-based fmSSFP MRI technique emerges as a time-efficient alternative to phase-cycled bSFFP. The method does not need intermediate preparation phases, offers high SNR and avoids banding artifacts. Reweighting of the reconstructed subspace coefficients allows for generating virtual spectral responses with applications to water/fat separation.
Collapse
Affiliation(s)
- Volkert Roeloffs
- Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany
| | - Sebastian Rosenzweig
- Institute for Diagnostic and Interventional Radiology, University Medical Center, Göttingen, Germany.,German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - H Christian M Holme
- Institute for Diagnostic and Interventional Radiology, University Medical Center, Göttingen, Germany.,German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - Martin Uecker
- Institute for Diagnostic and Interventional Radiology, University Medical Center, Göttingen, Germany.,German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - Jens Frahm
- Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany.,German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| |
Collapse
|
214
|
Emmerich J, Flassbeck S, Schmidt S, Bachert P, Ladd ME, Straub S. Rapid and accurate dictionary-based T 2 mapping from multi-echo turbo spin echo data at 7 Tesla. J Magn Reson Imaging 2018; 49:1253-1262. [PMID: 30328209 DOI: 10.1002/jmri.26516] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 08/03/2018] [Accepted: 09/04/2018] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Using lower refocusing flip angles in multi-echo turbo spin echo (ME-TSE) sequences at ultra-high magnetic field leads to non-monoexponential signal decay and overestimation of T2 values due to stimulated and secondary echoes. PURPOSE To investigate the feasibility of a fast and accurate reconstruction of quantitative T2 values using an ME-TSE sequence with reduced refocusing flip angles at 7 Tesla, a dictionary-based reconstruction method was developed and is presented in this work. STUDY TYPE Prospective. SUBJECTS Phantom measurements with relaxation phantom, four healthy volunteers. FIELD STRENGTH/SEQUENCE 7 Tesla MRI, multi-echo turbo spin echo (ME-TSE), spin echo (SE), and B1 mapping. ASSESSMENT Based on Bloch simulations and the extended phase graph model, signal decay curves were calculated to account for nonrectangular slice profile, B1 inhomogeneity, and reduced refocusing flip angles and stored in a dictionary. Data obtained with an ME-TSE sequence at 7 Tesla were matched to this dictionary to obtain T2 values. To compare the proposed method to reference T2 values, a spin echo sequence with different echo times was used. STATISTICAL TESTS Welch's t-test was used to compare T2 values in phantom measurements. RESULTS T2 values obtained with the proposed ME-TSE method coincided with the T2 values from the spin echo experiment in phantom measurements (P = 0.89 for 120° flip angle, P = 0.75 for 180° flip angle). Only for very low B1 transmit fields, a slight overestimation of T2 values was observed. In vivo measurements showed lower T2 values in gray matter (55 ± 2 millisecond) and white matter (39 ± 5 millisecond) compared with literature values of 3 Tesla data. DATA CONCLUSIONS The proposed dictionary-based ME-TSE approach provided accurate T2 values in short measurement time at 7 Tesla with low specific absorption rate burden due to the reduction of refocusing flip angles. Therefore, it can provide new opportunities in clinical high-field MRI to further improve radiographic diagnosis by using quantitative imaging. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1253-1262.
Collapse
Affiliation(s)
- Julian Emmerich
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Sebastian Flassbeck
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Simon Schmidt
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Peter Bachert
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Mark E Ladd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany.,Faculty of Medicine, Heidelberg University, Heidelberg, Germany
| | - Sina Straub
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
215
|
Ferrazzi G, Bassenge JP, Wink C, Ruh A, Markl M, Moeller S, Metzger GJ, Ittermann B, Schmitter S. Autocalibrated multiband CAIPIRINHA with through‐time encoding: Proof of principle and application to cardiac tissue phase mapping. Magn Reson Med 2018; 81:1016-1030. [DOI: 10.1002/mrm.27460] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 06/30/2018] [Accepted: 07/02/2018] [Indexed: 12/27/2022]
Affiliation(s)
- Giulio Ferrazzi
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| | - Jean Pierre Bassenge
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max‐Delbrueck Center for Molecular Medicine
| | - Clarissa Wink
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| | - Alexander Ruh
- Department of Radiology, Feinberg School of Medicine Northwestern University Chicago Illinois
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine Northwestern University Chicago Illinois
- Department of Biomedical Engineering, McCormick School of Engineering Northwestern University Chicago Illinois
| | - Steen Moeller
- University of Minnesota, Center for Magnetic Resonance Research (CMRR) Minneapolis Minnesota
| | - Gregory J. Metzger
- University of Minnesota, Center for Magnetic Resonance Research (CMRR) Minneapolis Minnesota
| | - Bernd Ittermann
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| | | |
Collapse
|
216
|
Wyatt CR, Smith TB, Sammi MK, Rooney WD, Guimaraes AR. Multi-parametric T 2 * magnetic resonance fingerprinting using variable echo times. NMR IN BIOMEDICINE 2018; 31:e3951. [PMID: 30011109 DOI: 10.1002/nbm.3951] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 03/29/2018] [Accepted: 05/01/2018] [Indexed: 06/08/2023]
Abstract
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T1 , T2 , and T2 * relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi-parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T2 * relaxation is added to the MRF framework using variable echo times (TE). To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T1 /T2 /T2 */δf MRF as well as conventional T1 , T2 , and T2 * acquisitions were acquired in agar phantoms and the brains of three healthy volunteers. Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T1 , T2 , and T2 * relaxation time constants of the agar phantoms and healthy volunteers. In this study, T2 * relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T1 and T2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.
Collapse
Affiliation(s)
- Cory R Wyatt
- Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, OR, USA
- Department of Diagnostic Radiology, Oregon Health & Sciences University, Portland, OR, USA
| | - Travis B Smith
- Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, OR, USA
- Casey Eye Institute, Oregon Health & Sciences University, Portland, OR, USA
| | - Manoj K Sammi
- Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, OR, USA
| | - William D Rooney
- Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, OR, USA
| | - Alexander R Guimaraes
- Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, OR, USA
- Department of Diagnostic Radiology, Oregon Health & Sciences University, Portland, OR, USA
| |
Collapse
|
217
|
Cohen O, Zhu B, Rosen MS. MR fingerprinting Deep RecOnstruction NEtwork (DRONE). Magn Reson Med 2018; 80:885-894. [PMID: 29624736 PMCID: PMC5980718 DOI: 10.1002/mrm.27198] [Citation(s) in RCA: 171] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 02/17/2018] [Accepted: 03/05/2018] [Indexed: 12/12/2022]
Abstract
PURPOSE Demonstrate a novel fast method for reconstruction of multi-dimensional MR Fingerprinting (MRF) data using Deep Learning methods. METHODS A neural network (NN) is defined using the TensorFlow framework and trained on simulated MRF data computed with the Extended Phase Graph formalism. The NN reconstruction accuracy for noiseless and noisy data is compared to conventional MRF template matching as a function of training data size, and quantified in simulated numerical brain phantom data and ISMRM/NIST phantom data measured on 1.5T and 3T scanners with an optimized MRF EPI and MRF FISP sequences with spiral readout. The utility of the method is demonstrated in a healthy subject in vivo at 1.5 T. RESULTS Network training required 10 to 74 minutes and once trained, data reconstruction required approximately 10 ms for the MRF EPI and 76 ms for the MRF FISP sequence. Reconstruction of simulated, noiseless brain data using the NN resulted in a root-mean-square error (RMSE) of 2.6 ms for T1 and 1.9 ms for T2. The reconstruction error in the presence of noise was less than 10% for both T1 and T2 for signal-to-noise greater than 25 dB. Phantom measurements yielded good agreement (R2=0.99/0.99 for MRF EPI T1/T2 and 0.94/0.98 for MRF FISP T1/T2) between the T1 and T2 estimated by the NN and reference values from the ISMRM/NIST phantom. CONCLUSION Reconstruction of MRF data with a NN is accurate, 300–5000 fold faster and more robust to noise and undersampling than conventional MRF dictionary matching.
Collapse
Affiliation(s)
- Ouri Cohen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA 02115 USA
- Department of Physics, Harvard University, Cambridge, MA 02138 USA
| | - Bo Zhu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA 02115 USA
- Department of Physics, Harvard University, Cambridge, MA 02138 USA
| | - Matthew S. Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129 USA
- Department of Radiology, Harvard Medical School, Boston, MA 02115 USA
- Department of Physics, Harvard University, Cambridge, MA 02138 USA
| |
Collapse
|
218
|
Sveinsson B, Gold GE, Hargreaves BA, Yoon D. SNR-weighted regularization of ADC estimates from double-echo in steady-state (DESS). Magn Reson Med 2018; 81:711-718. [PMID: 30125389 DOI: 10.1002/mrm.27436] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 05/17/2018] [Accepted: 06/07/2018] [Indexed: 11/07/2022]
Abstract
PURPOSE To improve the homogeneity and consistency of apparent diffusion coefficient (ADC) estimates in cartilage from the double-echo in steady-state (DESS) sequence by applying SNR-weighted regularization during post-processing. METHODS An estimation method that linearizes ADC estimates from DESS is used in conjunction with a smoothness constraint to suppress noise-induced variation in ADC estimates. Simulations, phantom scans, and in vivo scans are used to demonstrate how the method reduces ADC variability. Conventional diffusion-weighted echo-planar imaging (DW EPI) maps are acquired for comparison of mean and standard deviation (SD) of the ADC estimate. RESULTS Simulations and phantom scans demonstrated that the SNR-weighted regularization can produce homogenous ADC maps at varying levels of SNR, whereas non-regularized maps only estimate ADC accurately at high SNR levels. The in vivo maps showed that the SNR-weighted regularization produced ADC maps with similar heterogeneity to maps produced with standard DW EPI, but without the distortion of such reference scans. CONCLUSION A linear approximation of a simplified model of the relationship between DESS signals allows for fast SNR-weighted regularization of ADC maps that reduces estimation error in relatively short T2 tissue such as cartilage.
Collapse
Affiliation(s)
- Bragi Sveinsson
- A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts.,Department of Physics, Harvard University, Cambridge, Massachusetts
| | - Garry E Gold
- Department of Radiology, Stanford University, Stanford, California
| | | | - Daehyun Yoon
- Department of Radiology, Stanford University, Stanford, California
| |
Collapse
|
219
|
Wiesinger F, Menini A, Solana AB. Looping Star. Magn Reson Med 2018; 81:57-68. [DOI: 10.1002/mrm.27440] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 01/29/2018] [Accepted: 02/13/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Florian Wiesinger
- ASL Europe, GE Healthcare; Munich Germany
- Department of Neuroimaging; Institute of Psychiatry, Psychology & Neuroscience, King's College London; London United Kingdom
| | | | | |
Collapse
|
220
|
Cruz G, Schneider T, Bruijnen T, Gaspar AS, Botnar RM, Prieto C. Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO). PLoS One 2018; 13:e0201808. [PMID: 30092033 PMCID: PMC6084944 DOI: 10.1371/journal.pone.0201808] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 07/23/2018] [Indexed: 11/28/2022] Open
Abstract
Object To develop a novel approach for highly accelerated Magnetic Resonance Fingerprinting (MRF) acquisition. Materials and methods The proposed method combines parallel imaging, soft-gating and key-hole approaches to highly accelerate MRF acquisition. Slowly varying flip angles (FA), commonly used during MRF acquisition, lead to a smooth change in the signal contrast of consecutive time-point images. This assumption enables sharing of high frequency data between different time-points, similar to what is done in some dynamic MR imaging methods such as key-hole. The proposed approach exploits this information using a SOft-weighted key-HOle (MRF-SOHO) reconstruction to achieve high acceleration factors and/or increased resolution without compromising image quality or increasing scan time. MRF-SOHO was validated on a standard T1/T2 phantom and in in-vivo brain acquisitions reconstructing T1, T2 and proton density parametric maps. Results Accelerated MRF-SOHO using less data per time-point and less time-point images enabled a considerable reduction in scan time (up to 4.6x), while obtaining similar T1 and T2 accuracy and precision when compared to zero-filled MRF reconstruction. For the same number of spokes and time-points, the proposed method yielded an enhanced performance in quantifying parameters than the zero-filled MRF reconstruction, which was verified with 2, 1 and 0.7 (sub-millimetre) resolutions. Conclusion The proposed MRF-SOHO enabled a 4.6x scan time reduction for an in-plane spatial resolution of 2x2 mm2 when compared to zero-filled MRF and enabled sub-millimetric (0.7x0.7 mm2) resolution MRF.
Collapse
Affiliation(s)
- Gastao Cruz
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- * E-mail:
| | | | - Tom Bruijnen
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Andreia S. Gaspar
- Institute for Systems and Robotics / Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
221
|
Chan RW, Lau AZ, Detzler G, Thayalasuthan V, Nam RK, Haider MA. Evaluating the accuracy of multicomponent T 2 parameters for luminal water imaging of the prostate with acceleration using inner-volume 3D GRASE. Magn Reson Med 2018; 81:466-476. [PMID: 30058296 DOI: 10.1002/mrm.27372] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 04/26/2018] [Accepted: 04/27/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE Prostate cancer can be detected using a multicomponent T2 mapping technique termed luminal water imaging. The purpose of this study is twofold: 1) To accelerate the luminal water imaging acquisition by using inner volume selection as part of a gradient and spin echo sequence, and 2) to evaluate the accuracy of luminal water fractions and multicomponent T2 relaxation times. METHODS The accuracy of parameter estimates was assessed using Monte Carlo simulations, in phantom experiments and in the prostate (in 5 healthy subjects). Two fitting methods, nonnegative least squares and biexponential fitting with stimulated echo correction, were compared. RESULTS Results demonstrate that inner volume selection in a gradient and spin echo sequence is effective for accelerating prostate luminal water imaging by at least threefold. Evaluation of the accuracy shows that the estimated luminal water fractions are relatively accurate, but the short- and long-T2 relaxation times should be interpreted with caution in noisy scenarios (SNR < 100) and when the corresponding fractions are small ( < 0.5). The mean luminal water fractions obtained at SNR above 100 are 0.27 ± 0.07 for the peripheral zone for both fitting methods, 0.16 ± 0.04 for the transition zone with nonnegative least squares, and 0.16 ± 0.03 for the transition zone with biexponential fitting including stimulated echo correction. CONCLUSION The shortened scan duration allows the luminal water imaging sequence to be easily integrated into a standard multiparametric prostate MRI protocol.
Collapse
Affiliation(s)
- Rachel W Chan
- Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Angus Z Lau
- Sunnybrook Research Institute, Toronto, Ontario, Canada.,Medical Biophysics, University of Toronto, Ontario, Canada
| | - Garry Detzler
- Sunnybrook Research Institute, Toronto, Ontario, Canada
| | | | - Robert K Nam
- Division of Urology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | | |
Collapse
|
222
|
Leroi L, Coste A, de Rochefort L, Santin MD, Valabregue R, Mauconduit F, Giacomini E, Luong M, Chazel E, Valette J, Le Bihan D, Poupon C, Boumezbeur F, Rabrait-Lerman C, Vignaud A. Simultaneous multi-parametric mapping of total sodium concentration, T 1, T 2 and ADC at 7 T using a multi-contrast unbalanced SSFP. Magn Reson Imaging 2018; 53:156-163. [PMID: 30055291 DOI: 10.1016/j.mri.2018.07.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 07/23/2018] [Accepted: 07/23/2018] [Indexed: 01/10/2023]
Abstract
PURPOSE Quantifying multiple NMR properties of sodium could be of benefit to assess changes in cellular viability in biological tissues. A proof of concept of Quantitative Imaging using Configuration States (QuICS) based on a SSFP sequence with multiple contrasts was implemented to extract simultaneously 3D maps of applied flip angle (FA), total sodium concentration, T1, T2, and Apparent Diffusion Coefficient (ADC). METHODS A 3D Cartesian Gradient Recalled Echo (GRE) sequence was used to acquire 11 non-balanced SSFP contrasts at a 6 × 6 × 6 mm3 isotropic resolution with carefully-chosen gradient spoiling area, RF amplitude and phase cycling, with TR/TE = 20/3.2 ms and 25 averages, leading to a total acquisition time of 1 h 18 min. A least-squares fit between the measured and the analytical complex signals was performed to extract quantitative maps from a mono-exponential model. Multiple sodium phantoms with different compositions were studied to validate the ability of the method to measure sodium NMR properties in various conditions. RESULTS Flip angle maps were retrieved. Relaxation times, ADC and sodium concentrations were estimated with controlled precision below 15%, and were in accordance with measurements from established methods and literature. CONCLUSION The results illustrate the ability to retrieve sodium NMR properties maps, which is a first step toward the estimation of FA, T1, T2, concentration and ADC of 23Na for clinical research. With further optimization of the acquired QuICS contrasts, scan time could be reduced to be suitable with in vivo applications.
Collapse
Affiliation(s)
- Lisa Leroi
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Arthur Coste
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | | | - Mathieu D Santin
- CENIR, Centre de NeuroImagerie de Recherche, Paris, France; ICM, Inserm U 1127, CNRS UMR 7225, Sorbonne Universités, UPMC Université Paris 06 UMR S1127, Institut du Cerveau et de la Moelle épinière, Paris, France
| | - Romain Valabregue
- CENIR, Centre de NeuroImagerie de Recherche, Paris, France; ICM, Inserm U 1127, CNRS UMR 7225, Sorbonne Universités, UPMC Université Paris 06 UMR S1127, Institut du Cerveau et de la Moelle épinière, Paris, France
| | | | - Eric Giacomini
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Michel Luong
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Edouard Chazel
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Julien Valette
- Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), Direction de la Recherche Fondamentale (DRF), Institut de Biologie François Jacob, MIRCen, Fontenay-aux-Roses, France
| | - Denis Le Bihan
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Cyril Poupon
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | - Fawzi Boumezbeur
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France
| | | | - Alexandre Vignaud
- NeuroSpin, CEA, DRF/JOLIOT, Université Paris-Saclay, Gif-sur-Yvette, France.
| |
Collapse
|
223
|
Qiao Y, Zou C, Cheng C, Wan Q, Tie C, Liang D, Zheng H, Liu X, Chung YC. Diffusion effect on T2 relaxometry in triple-echo steady state free precession sequence. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 292:25-35. [PMID: 29758451 DOI: 10.1016/j.jmr.2018.04.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Revised: 04/28/2018] [Accepted: 04/29/2018] [Indexed: 06/08/2023]
Abstract
PURPOSE The purpose of this study is to evaluate the effect of diffusion on SSFP (Steady-state Free Precession) signals in triple-echo steady state (TESS) sequence and ultimately on the accuracy of T2 relaxometry. METHODS The extended phase graph (EPG) algorithm was used to study the effect of diffusion on SSFP signals and T2 relaxometry. The simulation results were verified by a commercial phantom and in vivo studies. Based on the simulation results, a correction scheme was proposed to correct the estimated T2 values. RESULTS T2 underestimation in TESS was evident in case of small flip angle and large unbalanced gradient moment on objects with large T2 and D values. The T2 underestimation mainly originated from the diffusion sensitivity of SSFP-echo. It was also observed that SSFP-FID (Free Induction Decay) signals increased with increasing diffusion weighting under some specific conditions. The proposed correction scheme corrected the T2 underestimation, which verified that the underestimation was due to the neglect of diffusion effect. For clinical practice of TESS in tissues with short T2 such as cartilage and muscle, the diffusion effect of TESS is negligible. CONCLUSION The effect of diffusion cannot be neglected during TESS T2 quantification as it is the main source of T2 underestimation when small flip angle and large unbalanced gradient moment is used, especially for objects with large T2 and D values.
Collapse
Affiliation(s)
- Yangzi Qiao
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Chao Zou
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Chuanli Cheng
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China; University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Qian Wan
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Changjun Tie
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Dong Liang
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Hairong Zheng
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Xin Liu
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China; Chongqing Collaborative Innovation Center, Chongqing, People's Republic of China.
| | | |
Collapse
|
224
|
Kobayashi Y, Terada Y. Diffusion-weighting Caused by Spoiler Gradients in the Fast Imaging with Steady-state Precession Sequence May Lead to Inaccurate T 2 Measurements in MR Fingerprinting. Magn Reson Med Sci 2018; 18:96-104. [PMID: 29794408 PMCID: PMC6326765 DOI: 10.2463/mrms.tn.2018-0027] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a promising framework that allows the quantification of multiple magnetic resonance parameters with a single scan. MRF using fast imaging with steady-state precession (MRF-FISP) has robustness to off-resonance artifacts and has many applications in inhomogeneous fields. However, the spoiler gradient used in MRF-FISP is sensitive to diffusion motion, and may lead to quantification errors when the spoiler moment increases. In this study, we examined the effect of the diffusion weighting in MRF-FISP caused by spoiler gradients. The T2 relaxation times were greatly underestimated when large spoiler moments were used. The T2 underestimation was prominent for tissues with large values of T2 and diffusion coefficients. The T2 bias was almost independent of the apparent diffusion coefficient (ADC) and T2 values when the ADC map was measured and incorporated into the matching process. These results reveal that the T2 underestimation resulted from the diffusion weighting caused by the spoiler gradients.
Collapse
|
225
|
Chikop SA, Anchan ABS, Koulagi G, Honnedevasthana AA, Imam S, Geethanath S. Automatic motion correction of Musculoskeletal MRI using DSLR camera. Magn Reson Imaging 2018; 48:74-79. [DOI: 10.1016/j.mri.2017.12.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Accepted: 12/29/2017] [Indexed: 10/18/2022]
|
226
|
Benkert T, Mugler JP, Rigie DS, Sodickson DK, Chandarana H, Block KT. Hybrid T 2 - and T 1 -weighted radial acquisition for free-breathing abdominal examination. Magn Reson Med 2018; 80:1935-1948. [PMID: 29656522 DOI: 10.1002/mrm.27200] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 02/14/2018] [Accepted: 03/09/2018] [Indexed: 12/13/2022]
Abstract
PURPOSE Most clinical MR examinations require acquisition of different image contrasts. For abdominal exams, the scans are conventionally performed as separate acquisitions using respiratory gating or repeated breath holding, which can be time-inefficient and challenging for patients. Here, a hybrid imaging approach is described that creates T2 - and T1 -weighted images from a single scan and allows for free-breathing acquisition. THEORY AND METHODS T2 -weighted data is collected using 3D fast spin-echo (FSE) acquisition with motion-robust radial stack-of-stars sampling. The wait time between the FSE trains is used to acquire T1 -weighted gradient-echo (GRE) data. Improved robustness is achieved by extracting a respiratory signal from the GRE data and using it for motion-weighted reconstruction. RESULTS As validated in simulations and phantom scans, GRE acquisition in the wait time has minor effect on the signal strength and contrast. Volunteer scans at 1.5T showed that T2 - and T1 -weighted hybrid imaging is feasible during free-breathing. Furthermore, it has been demonstrated in a patient that hybrid imaging with T1 -weighted Dixon acquisition is possible. CONCLUSION The described hybrid sequence enables comprehensive T2 - and T1 -weighted imaging in a single scan. In addition to free-breathing abdominal examination, it promises value for clinical applications that are frequently affected by motion artifacts.
Collapse
Affiliation(s)
- Thomas Benkert
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York.,Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York
| | - John P Mugler
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia
| | - David S Rigie
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York.,Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York.,Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York
| | - Hersh Chandarana
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York.,Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York
| | - Kai Tobias Block
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York.,Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York
| |
Collapse
|
227
|
Carlier PG, Marty B, Scheidegger O, Loureiro de Sousa P, Baudin PY, Snezhko E, Vlodavets D. Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials. J Neuromuscul Dis 2018; 3:1-28. [PMID: 27854210 PMCID: PMC5271435 DOI: 10.3233/jnd-160145] [Citation(s) in RCA: 127] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Recent years have seen tremendous progress towards therapy of many previously incurable neuromuscular diseases. This new context has acted as a driving force for the development of novel non-invasive outcome measures. These can be organized in three main categories: functional tools, fluid biomarkers and imagery. In the latest category, nuclear magnetic resonance imaging (NMRI) offers a considerable range of possibilities for the characterization of skeletal muscle composition, function and metabolism. Nowadays, three NMR outcome measures are frequently integrated in clinical research protocols. They are: 1/ the muscle cross sectional area or volume, 2/ the percentage of intramuscular fat and 3/ the muscle water T2, which quantity muscle trophicity, chronic fatty degenerative changes and oedema (or more broadly, “disease activity”), respectively. A fourth biomarker, the contractile tissue volume is easily derived from the first two ones. The fat fraction maps most often acquired with Dixon sequences have proven their capability to detect small changes in muscle composition and have repeatedly shown superior sensitivity over standard functional evaluation. This outcome measure will more than likely be the first of the series to be validated as an endpoint by regulatory agencies. The versatility of contrast generated by NMR has opened many additional possibilities for characterization of the skeletal muscle and will result in the proposal of more NMR biomarkers. Ultra-short TE (UTE) sequences, late gadolinium enhancement and NMR elastography are being investigated as candidates to evaluate skeletal muscle interstitial fibrosis. Many options exist to measure muscle perfusion and oxygenation by NMR. Diffusion NMR as well as texture analysis algorithms could generate complementary information on muscle organization at microscopic and mesoscopic scales, respectively. 31P NMR spectroscopy is the reference technique to assess muscle energetics non-invasively during and after exercise. In dystrophic muscle, 31P NMR spectrum at rest is profoundly perturbed, and several resonances inform on cell membrane integrity. Considerable efforts are being directed towards acceleration of image acquisitions using a variety of approaches, from the extraction of fat content and water T2 maps from one single acquisition to partial matrices acquisition schemes. Spectacular decreases in examination time are expected in the near future. They will reinforce the attractiveness of NMR outcome measures and will further facilitate their integration in clinical research trials.
Collapse
Affiliation(s)
- Pierre G Carlier
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,CEA, DSV, I2BM, MIRCen, NMR Laboratory, Paris, France.,National Academy of Sciences, United Institute for Informatics Problems, Minsk, Belarus
| | - Benjamin Marty
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,CEA, DSV, I2BM, MIRCen, NMR Laboratory, Paris, France
| | - Olivier Scheidegger
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,Support Center for Advanced Neuroimaging (SCAN), Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, and University of Bern, Switzerland
| | | | | | - Eduard Snezhko
- National Academy of Sciences, United Institute for Informatics Problems, Minsk, Belarus
| | - Dmitry Vlodavets
- N.I. Prirogov Russian National Medical Research University, Clinical Research Institute of Pediatrics, Moscow, Russian Federation
| |
Collapse
|
228
|
Shin T, Qin Q. Characterization and suppression of stripe artifact in velocity-selective magnetization-prepared unenhanced MR angiography. Magn Reson Med 2018. [PMID: 29536569 DOI: 10.1002/mrm.27160] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
PURPOSE To characterize and suppress stripe artifact associated with velocity-selective (VS) magnetization for unenhanced MRA. METHODS Extended phase graph formalism was used to show that the stripe artifact contains multiples of the fundamental frequency that is determined by the area of unipolar VS gradient. Four VS preparation pulses whose excitation profiles are spatially shifted by quarter the fundamental period of the stripes, were applied alternately. For further suppression of the artifact, k-space data at kz = 0 were averaged over the 4 VS preparations. The proposed schemes were tested in a chicken breast phantom and healthy human subjects. RESULTS When the standard VS preparation scheme was used, stripe artifact was shown in all the reconstructed images and appeared as artifactual peaks in k-space that corresponded to the first and second order harmonics of the fundamental frequency. Alternate application of the 4 phase-shifted VS preparation pulses suppressed the stripes, but not completely, as evidenced by residual erroneous peaks in k-space. After the k-space averaging, the stripe artifact was nearly eliminated. CONCLUSION Stripe artifact in VS-MRA consists of multiples of the fundamental frequency and can be effectively suppressed through alternate application of phase-shifted VS preparations along with k-space averaging.
Collapse
Affiliation(s)
- Taehoon Shin
- Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, South Korea.,Department of Medicine, Case Western Reserve University, Cleveland, Ohio
| | - Qin Qin
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland
| |
Collapse
|
229
|
Tao S, Weavers PT, Trzasko JD, Huston J, Shu Y, Gray EM, Foo TK, Bernstein MA. The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems. Magn Reson Med 2018; 79:1354-1364. [PMID: 28643408 PMCID: PMC5741528 DOI: 10.1002/mrm.26789] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 05/22/2017] [Accepted: 05/23/2017] [Indexed: 11/10/2022]
Abstract
PURPOSE To investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first-order spatial dependence on fast/turbo spin-echo acquisitions, and to demonstrate the effectiveness of their real-time compensation. METHODS After briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first-order CFs on these systems are investigated using extended-phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real-time compensations using frequency tracking and gradient pre-emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan-based correction to compensate for eddy currents is also investigated. RESULTS It is demonstrated that, unlike the second-order CFs on conventional gradients, the additional zeroth/first-order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin-echo acquisitions within a typical brain-scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real-time compensation successfully eliminates the artifacts. CONCLUSIONS We demonstrate that the zeroth/first-order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real-time compensation. Magn Reson Med 79:1354-1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Shengzhen Tao
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
- Mayo Graduate School, Mayo Clinic, Rochester, Minnesota, USA
| | - Paul T. Weavers
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - John Huston
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Yunhong Shu
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Erin M. Gray
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | | |
Collapse
|
230
|
Zhao L, Chang CD, Alsop DC. Controlling T 2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering. Magn Reson Med 2018; 80:1391-1401. [PMID: 29427325 DOI: 10.1002/mrm.27118] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 01/12/2018] [Accepted: 01/14/2018] [Indexed: 11/06/2022]
Abstract
PURPOSE To improve the SNR efficiency and reduce the T2 blurring of 3D rapid acquisition with relaxation enhancement stack-of-spiral arterial spin labeling imaging by using variable refocusing flip angles and k-space filtering. METHODS An algorithm for determining the optimal combination of variable flip angles and filtering correction is proposed. The flip angles are designed using extended phase graph physical simulations in an analytical and global optimization framework, with an optional constraint on deposited power. Optimal designs for correcting to Hann and Fermi window functions were compared with conventional constant amplitude or variable flip angle only designs on 6 volunteers. RESULTS With the Fermi window correction, the proposed optimal designs provided 39.8 and 27.3% higher SNR (P < .05) than conventional constant amplitude and variable flip angle designs. Even when power deposition was limited to 50% of the constant amplitude design, the proposed method outperformed the SNR (P < .05) of these 2 conventional approaches by 32.5 and 20.7%. The sharpness and the contrast between gray and white matter were improved with the k-space filtering correction for all of the flip angle designs. The improvements were moderate for the Hann window correction. CONCLUSION This work demonstrates that variable flip angles can be derived as the output of an optimization problem. The combined design of variable flip angle and k-space filtering provided superior SNR to designs primarily emphasizing either approach singly.
Collapse
Affiliation(s)
- Li Zhao
- Department of Radiology, Beth Israel Deaconess Medical Center & Harvard Medical School, Boston, Massachusetts, USA
| | - Ching-Di Chang
- Department of Radiology, Beth Israel Deaconess Medical Center & Harvard Medical School, Boston, Massachusetts, USA.,Department of Radiology, Kaohsiung Chang Gung Memorial Hospital & Chang Gung University College of Medicine, Kaohsiung city, Taiwan
| | - David C Alsop
- Department of Radiology, Beth Israel Deaconess Medical Center & Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
231
|
He X, Wengler K, Schweitzer ME. Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion. Magn Reson Med 2018; 80:736-747. [DOI: 10.1002/mrm.27058] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 11/02/2017] [Accepted: 12/05/2017] [Indexed: 12/21/2022]
Affiliation(s)
- Xiang He
- Department of Radiology; Stony Brook University; Stony Brook New York USA
| | - Kenneth Wengler
- Department of Biomedical Engineering; Stony Brook University; Stony Brook New York USA
| | - Mark E. Schweitzer
- Department of Radiology; Stony Brook University; Stony Brook New York USA
| |
Collapse
|
232
|
Lattanzi R, Zhang B, Knoll F, Assländer J, Cloos MA. Phase unwinding for dictionary compression with multiple channel transmission in magnetic resonance fingerprinting. Magn Reson Imaging 2017; 49:32-38. [PMID: 29278766 DOI: 10.1016/j.mri.2017.12.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 12/12/2017] [Accepted: 12/21/2017] [Indexed: 11/28/2022]
Abstract
PURPOSE Magnetic Resonance Fingerprinting reconstructions can become computationally intractable with multiple transmit channels, if the B1+ phases are included in the dictionary. We describe a general method that allows to omit the transmit phases. We show that this enables straightforward implementation of dictionary compression to further reduce the problem dimensionality. METHODS We merged the raw data of each RF source into a single k-space dataset, extracted the transceiver phases from the corresponding reconstructed images and used them to unwind the phase in each time frame. All phase-unwound time frames were combined in a single set before performing SVD-based compression. We conducted synthetic, phantom and in-vivo experiments to demonstrate the feasibility of SVD-based compression in the case of two-channel transmission. RESULTS Unwinding the phases before SVD-based compression yielded artifact-free parameter maps. For fully sampled acquisitions, parameters were accurate with as few as 6 compressed time frames. SVD-based compression performed well in-vivo with highly under-sampled acquisitions using 16 compressed time frames, which reduced reconstruction time from 750 to 25min. CONCLUSION Our method reduces the dimensions of the dictionary atoms and enables to implement any fingerprint compression strategy in the case of multiple transmit channels.
Collapse
Affiliation(s)
- Riccardo Lattanzi
- Center for Advanced Imaging Innovation and Research (CAI(2)R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 1st Ave., New York, NY 10016, USA; The Sackler Institute at the New York University School of Medicine, 550 First Avenue, New York, NY 10016, USA.
| | - Bei Zhang
- Center for Advanced Imaging Innovation and Research (CAI(2)R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 1st Ave., New York, NY 10016, USA
| | - Florian Knoll
- Center for Advanced Imaging Innovation and Research (CAI(2)R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 1st Ave., New York, NY 10016, USA
| | - Jakob Assländer
- Center for Advanced Imaging Innovation and Research (CAI(2)R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 1st Ave., New York, NY 10016, USA
| | - Martijn A Cloos
- Center for Advanced Imaging Innovation and Research (CAI(2)R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 1st Ave., New York, NY 10016, USA
| |
Collapse
|
233
|
Soustelle L, Lamy J, Rousseau F, Armspach JP, Loureiro de Sousa P. A diffusion-based method for long-T2suppression in steady state sequences: Validation and application for 3D-UTE imaging. Magn Reson Med 2017; 80:548-559. [DOI: 10.1002/mrm.27057] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 12/01/2017] [Accepted: 12/01/2017] [Indexed: 12/21/2022]
Affiliation(s)
- Lucas Soustelle
- Université de Strasbourg, CNRS, ICube, FMTS; Strasbourg France
| | - Julien Lamy
- Université de Strasbourg, CNRS, ICube, FMTS; Strasbourg France
| | | | | | | |
Collapse
|
234
|
Malik SJ, Teixeira RPAG, Hajnal JV. Extended phase graph formalism for systems with magnetization transfer and exchange. Magn Reson Med 2017; 80:767-779. [PMID: 29243295 PMCID: PMC5947218 DOI: 10.1002/mrm.27040] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Revised: 11/02/2017] [Accepted: 11/19/2017] [Indexed: 01/23/2023]
Abstract
Purpose An extended phase graph framework (EPG‐X) for modeling systems with exchange or magnetization transfer (MT) is proposed. Theory EPG‐X models coupled two‐compartment systems by describing each compartment with separate phase graphs that exchange during evolution periods. There are two variants: EPG‐X(BM) for systems governed by the Bloch‐McConnell equations, and EPG‐X(MT) for the pulsed MT formalism. For the MT case, the “bound” protons have no transverse components, so their phase graph consists of only longitudinal states. Methods The EPG‐X model was validated against steady‐state solutions and isochromat‐based simulation of gradient‐echo sequences. Three additional test cases were investigated: (i) MT effects in multislice turbo spin‐echo; (ii) variable flip angle gradient‐echo imaging of the type used for MR fingerprinting; and (iii) water exchange in multi‐echo spin‐echo T2 relaxometry. Results EPG‐X was validated successfully against isochromat based transient simulations and known steady‐state solutions. EPG‐X(MT) simulations matched in‐vivo measurements of signal attenuation in white matter in multislice turbo spin‐echo images. Magnetic resonance fingerprinting–style experiments with a bovine serum albumin (MT) phantom showed that the data were not consistent with a single‐pool model, but EPG‐X(MT) could be used to fit the data well. The EPG‐X(BM) simulations of multi‐echo spin‐echo T2 relaxometry suggest that exchange could lead to an underestimation of the myelin‐water fraction. Conclusions The EPG‐X framework can be used for modeling both steady‐state and transient signal response of systems exhibiting exchange or MT. This may be particularly beneficial for relaxometry approaches that rely on characterizing transient rather than steady‐state sequences. Magn Reson Med 80:767–779, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Shaihan J Malik
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Rui Pedro A G Teixeira
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Joseph V Hajnal
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, SE1 7EH, United Kingdom
| |
Collapse
|
235
|
Martin T, Wang Y, Rashid S, Shao X, Moeller S, Hu P, Sung K, Wang DJJ. Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP). INVESTIGATIVE MAGNETIC RESONANCE IMAGING 2017; 21:210-222. [PMID: 29520372 PMCID: PMC5839645 DOI: 10.13104/imri.2017.21.4.210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 08/26/2017] [Accepted: 09/09/2017] [Indexed: 11/15/2022]
Abstract
PURPOSE To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. MATERIALS AND METHODS CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. RESULTS Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. CONCLUSION This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.
Collapse
Affiliation(s)
- Thomas Martin
- Department of Radiological Sciences, University of California Los Angeles, California, USA
| | - Yi Wang
- Philips, MR Clinical Science NA, Florida, USA
| | - Shams Rashid
- Department of Radiological Sciences, University of California Los Angeles, California, USA
| | - Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, University of Southern California, California, USA
| | - Steen Moeller
- Center of Magnetic Resonance Research, University of Minnesota, Minnesota, USA
| | - Peng Hu
- Department of Radiological Sciences, University of California Los Angeles, California, USA
| | - Kyunghyun Sung
- Department of Radiological Sciences, University of California Los Angeles, California, USA
| | - Danny JJ Wang
- Laboratory of FMRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, University of Southern California, California, USA
| |
Collapse
|
236
|
Ferrazzi G, Price AN, Teixeira RPAG, Cordero-Grande L, Hutter J, Gomes A, Padormo F, Hughes E, Schneider T, Rutherford M, Kuklisova Murgasova M, Hajnal JV. An efficient sequence for fetal brain imaging at 3T with enhanced T 1 contrast and motion robustness. Magn Reson Med 2017; 80:137-146. [PMID: 29193244 PMCID: PMC5900721 DOI: 10.1002/mrm.27012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 10/25/2017] [Accepted: 10/26/2017] [Indexed: 11/11/2022]
Abstract
PURPOSE Ultrafast single-shot T2 -weighted images are common practice in fetal MR exams. However, there is limited experience with fetal T1 -weighted acquisitions. This study aims at establishing a robust framework that allows fetal T1 -weighted scans to be routinely acquired in utero at 3T. METHODS A 2D gradient echo sequence with an adiabatic inversion was optimized to be robust to fetal motion and maternal breathing optimizing grey/white matter contrast at the same time. This was combined with slice to volume registration and super resolution methods to produce volumetric reconstructions. The sequence was tested on 22 fetuses. RESULTS Optimized grey/white matter contrast and robustness to fetal motion and maternal breathing were achieved. Signal from cerebrospinal fluid (CSF) and amniotic fluid was nulled and 0.75 mm isotropic anatomical reconstructions of the fetal brain were obtained using slice-to-volume registration and super resolution techniques. Total acquisition time for a single stack was 56 s, all acquired during free breathing. Enhanced sensitivity to normal anatomy and pathology with respect to established methods is demonstrated. A direct comparison with a 3D spoiled gradient echo sequence and a controlled motion experiment run on an adult volunteer are also shown. CONCLUSION This paper describes a robust framework to perform T1 -weighted acquisitions and reconstructions of the fetal brain in utero. Magn Reson Med 80:137-146, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Collapse
Affiliation(s)
- Giulio Ferrazzi
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Anthony N Price
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Rui Pedro A G Teixeira
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Lucilio Cordero-Grande
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Jana Hutter
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Ana Gomes
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Francesco Padormo
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK.,Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Emer Hughes
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | | | - Mary Rutherford
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Maria Kuklisova Murgasova
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| | - Joseph V Hajnal
- Centre for the Developing Brain, Department of Perinatal Imaging and Health, Division of Imaging Sciences and Biomedical Engineering, King's College, London, UK
| |
Collapse
|
237
|
Ginami G, Neji R, Rashid I, Chiribiri A, Ismail TF, Botnar RM, Prieto C. 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography. J Cardiovasc Magn Reson 2017; 19:94. [PMID: 29178893 PMCID: PMC5702978 DOI: 10.1186/s12968-017-0405-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Accepted: 11/06/2017] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Phase sensitive inversion recovery (PSIR) applied to late gadolinium enhancement (LGE) imaging is widely used in clinical practice. However, conventional 2D PSIR LGE sequences provide sub-optimal contrast between scar tissue and blood pool, rendering the detection of subendocardial infarcts and scar segmentation challenging. Furthermore, the acquisition of a low flip angle reference image doubles the acquisition time without providing any additional diagnostic information. The purpose of this study was to develop and test a novel 3D whole-heart PSIR-like framework, named BOOST, enabling simultaneous black-blood LGE assessment and bright-blood visualization of cardiac anatomy. METHODS The proposed approach alternates the acquisition of a 3D volume preceded by a T2-prepared Inversion Recovery (T2Prep-IR) module (magnitude image) with the acquisition of a T2-prepared 3D volume (reference image). The two volumes (T2Prep-IR BOOST and bright-blood T2Prep BOOST) are combined in a PSIR-like reconstruction to obtain a complementary 3D black-blood volume for LGE assessment (PSIR BOOST). The black-blood PSIR BOOST and the bright-blood T2Prep BOOST datasets were compared to conventional clinical sequences for scar detection and coronary CMR angiography (CMRA) in 18 patients with a spectrum of cardiovascular disease (CVD). RESULTS Datasets from 12 patients were quantitatively analysed. The black-blood PSIR BOOST dataset provided statistically improved contrast to noise ratio (CNR) between blood and scar when compared to a clinical 2D PSIR sequence (15.8 ± 3.3 and 4.1 ± 5.6, respectively). Overall agreement in LGE depiction was found between 3D black-blood PSIR BOOST and clinical 2D PSIR acquisitions, with 11/12 PSIR BOOST datasets considered diagnostic. The bright-blood T2Prep BOOST dataset provided high quality depiction of the proximal coronary segments, with improvement of visual score when compared to a clinical CMRA sequence. Acquisition time of BOOST (~10 min), providing information on both LGE uptake and heart anatomy, was comparable to that of a clinical single CMRA sequence. CONCLUSIONS The feasibility of BOOST for simultaneous black-blood LGE assessment and bright-blood coronary angiography was successfully tested in patients with cardiovascular disease. The framework enables free-breathing multi-contrast whole-heart acquisitions with 100% scan efficiency and predictable scan time. Complementary information on 3D LGE and heart anatomy are obtained reducing examination time.
Collapse
Affiliation(s)
- Giulia Ginami
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
- MR Research Collaborations, Siemens Healthcare Limited, Sir William Siemens Square Frimley, Camberley, GU16 8QD UK
| | - Imran Rashid
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
| | - Tevfik F. Ismail
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Vicuna Mackenna, 4860 Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ Hospital (Lambeth Wing), Westminster Bridge Rd, London, SE1 7EH UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Vicuna Mackenna, 4860 Santiago, Chile
| |
Collapse
|
238
|
Liao C, Bilgic B, Manhard MK, Zhao B, Cao X, Zhong J, Wald LL, Setsompop K. 3D MR fingerprinting with accelerated stack-of-spirals and hybrid sliding-window and GRAPPA reconstruction. Neuroimage 2017; 162:13-22. [PMID: 28842384 PMCID: PMC6031129 DOI: 10.1016/j.neuroimage.2017.08.030] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 07/02/2017] [Accepted: 08/09/2017] [Indexed: 12/13/2022] Open
Abstract
PURPOSE Whole-brain high-resolution quantitative imaging is extremely encoding intensive, and its rapid and robust acquisition remains a challenge. Here we present a 3D MR fingerprinting (MRF) acquisition with a hybrid sliding-window (SW) and GRAPPA reconstruction strategy to obtain high-resolution T1, T2 and proton density (PD) maps with whole brain coverage in a clinically feasible timeframe. METHODS 3D MRF data were acquired using a highly under-sampled stack-of-spirals trajectory with a steady-state precession (FISP) sequence. For data reconstruction, kx-ky under-sampling was mitigated using SW combination along the temporal axis. Non-uniform fast Fourier transform (NUFFT) was then applied to create Cartesian k-space data that are fully-sampled in the in-plane direction, and Cartesian GRAPPA was performed to resolve kz under-sampling to create an alias-free SW dataset. T1, T2 and PD maps were then obtained using dictionary matching. RESULTS Phantom study demonstrated that the proposed 3D-MRF acquisition/reconstruction method is able to produce quantitative maps that are consistent with conventional quantification techniques. Retrospectively under-sampled in vivo acquisition revealed that SW + GRAPPA substantially improves quantification accuracy over the current state-of-the-art accelerated 3D MRF. Prospectively under-sampled in vivo study showed that whole brain T1, T2 and PD maps with 1 mm3 resolution could be obtained in 7.5 min. CONCLUSIONS 3D MRF stack-of-spirals acquisition with hybrid SW + GRAPPA reconstruction may provide a feasible approach for rapid, high-resolution quantitative whole-brain imaging.
Collapse
Affiliation(s)
- Congyu Liao
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Mary Kate Manhard
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Bo Zhao
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Xiaozhi Cao
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Jianhui Zhong
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China.
| | - Lawrence L Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Kawin Setsompop
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
239
|
Chaudhari AS, Black MS, Eijgenraam S, Wirth W, Maschek S, Sveinsson B, Eckstein F, Oei EHG, Gold GE, Hargreaves BA. Five-minute knee MRI for simultaneous morphometry and T 2 relaxometry of cartilage and meniscus and for semiquantitative radiological assessment using double-echo in steady-state at 3T. J Magn Reson Imaging 2017; 47:1328-1341. [PMID: 29090500 DOI: 10.1002/jmri.25883] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 10/14/2017] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Biomarkers for assessing osteoarthritis activity necessitate multiple MRI sequences with long acquisition times. PURPOSE To perform 5-minute simultaneous morphometry (thickness/volume measurements) and T2 relaxometry of both cartilage and meniscus, and semiquantitative MRI Osteoarthritis Knee Scoring (MOAKS). STUDY TYPE Prospective. SUBJECTS Fifteen healthy volunteers for morphometry and T2 measurements, and 15 patients (five each Kellgren-Lawrence grades 0/2/3) for MOAKS assessment. FIELD STRENGTH/SEQUENCE A 5-minute double-echo steady-state (DESS) sequence was evaluated for generating quantitative and semiquantitative osteoarthritis biomarkers at 3T. ASSESSMENT Flip angle simulations evaluated tissue signals and sensitivity of T2 measurements. Morphometry and T2 reproducibility was compared against morphometry-optimized and relaxometry-optimized sequences. Repeatability was assessed by scanning five volunteers twice. MOAKS reproducibility was compared to MOAKS derived from a clinical knee MRI protocol by two readers. STATISTICAL TESTS Coefficients of variation (CVs), concordance confidence intervals (CCI), and Wilcoxon signed-rank tests compared morphometry and relaxometry measurements with their reference standards. DESS MOAKS positive percent agreement (PPA), negative percentage agreement (NPA), and interreader agreement was calculated using the clinical protocol as a reference. Biomarker variations between Kellgren-Lawrence groups were evaluated using Wilcoxon rank-sum tests. RESULTS Cartilage thickness (P = 0.65), cartilage T2 (P = 0.69), and meniscus T2 (P = 0.06) did not significantly differ from their reference standard (with a 20° DESS flip angle). DESS slightly overestimated meniscus volume (P < 0.001). Accuracy and repeatability CVs were <3.3%, except the meniscus T2 accuracy (7.6%). DESS MOAKS had substantial interreader agreement and high PPA/NPA values of 87%/90%. Bone marrow lesions and menisci had slightly lower PPAs. Cartilage and meniscus T2 , and MOAKS (cartilage surface area, osteophytes, cysts, and total score) was higher in Kellgren-Lawrence groups 2 and 3 than group 0 (P < 0.05). DATA CONCLUSION The 5-minute DESS sequence permits MOAKS assessment for a majority of tissues, along with repeatable and reproducible simultaneous cartilage and meniscus T2 relaxometry and morphometry measurements. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1328-1341.
Collapse
Affiliation(s)
- Akshay S Chaudhari
- Department of Radiology, Stanford University, Stanford, California, USA.,Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Marianne S Black
- Department of Radiology, Stanford University, Stanford, California, USA.,Department of Mechanical Engineering, Stanford University, Stanford, California, USA
| | - Susanne Eijgenraam
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, Netherlands
| | - Wolfgang Wirth
- Institute of Anatomy, Paracelsus Medical University Salzburg and Nuremberg, Salzburg, Austria.,Chondrometrics GmbH, Ainring, Germany
| | - Susanne Maschek
- Institute of Anatomy, Paracelsus Medical University Salzburg and Nuremberg, Salzburg, Austria.,Chondrometrics GmbH, Ainring, Germany
| | - Bragi Sveinsson
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Felix Eckstein
- Institute of Anatomy, Paracelsus Medical University Salzburg and Nuremberg, Salzburg, Austria.,Chondrometrics GmbH, Ainring, Germany
| | - Edwin H G Oei
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, Netherlands
| | - Garry E Gold
- Department of Radiology, Stanford University, Stanford, California, USA.,Department of Bioengineering, Stanford University, Stanford, California, USA
| | - Brian A Hargreaves
- Department of Radiology, Stanford University, Stanford, California, USA.,Department of Bioengineering, Stanford University, Stanford, California, USA.,Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
240
|
Cao P, Zhu X, Tang S, Leynes A, Jakary A, Larson PEZ. Shuffled magnetization-prepared multicontrast rapid gradient-echo imaging. Magn Reson Med 2017; 79:62-70. [PMID: 29080236 DOI: 10.1002/mrm.26986] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 10/04/2017] [Accepted: 10/05/2017] [Indexed: 01/12/2023]
Abstract
PURPOSE To develop a novel acquisition and reconstruction method for magnetization-prepared 3-dimensional multicontrast rapid gradient-echo imaging, using Hankel matrix completion in combination with compressed sensing and parallel imaging. METHODS A random k-space shuffling strategy was implemented in simulation and in vivo human experiments at 7 T for 3-dimensional inversion recovery, T2 /diffusion preparation, and magnetization transfer imaging. We combined compressed sensing, based on total variation and spatial-temporal low-rank regularizations, and parallel imaging with pixel-wise Hankel matrix completion, allowing the reconstruction of tens of multicontrast 3-dimensional images from 3- or 6-min scans. RESULTS The simulation result showed that the proposed method can reconstruct signal-recovery curves in each voxel and was robust for typical in vivo signal-to-noise ratio with 16-times acceleration. In vivo studies achieved 4 to 24 times accelerations for inversion recovery, T2 /diffusion preparation, and magnetization transfer imaging. Furthermore, the contrast was improved by resolving pixel-wise signal-recovery curves after magnetization preparation. CONCLUSIONS The proposed method can improve acquisition efficiencies for magnetization-prepared MRI and tens of multicontrast 3-dimensional images could be recovered from a single scan. Furthermore, it was robust against noise, applicable for recovering multi-exponential signals, and did not require any previous knowledge of model parameters. Magn Reson Med 79:62-70, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Peng Cao
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Xucheng Zhu
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Shuyu Tang
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Andrew Leynes
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Angela Jakary
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
241
|
Cai C, Zeng Y, Zhuang Y, Cai S, Chen L, Ding X, Bao L, Zhong J, Chen Z. Single-Shot ${\text{T}}_{{2}}$ Mapping Through OverLapping-Echo Detachment (OLED) Planar Imaging. IEEE Trans Biomed Eng 2017; 64:2450-2461. [DOI: 10.1109/tbme.2017.2661840] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
242
|
Cohen O, Rosen MS. Algorithm comparison for schedule optimization in MR fingerprinting. Magn Reson Imaging 2017; 41:15-21. [DOI: 10.1016/j.mri.2017.02.010] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 02/15/2017] [Accepted: 02/20/2017] [Indexed: 11/30/2022]
|
243
|
Kose R, Kose K. BlochSolver: A GPU-optimized fast 3D MRI simulator for experimentally compatible pulse sequences. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 281:51-65. [PMID: 28550818 DOI: 10.1016/j.jmr.2017.05.007] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 05/15/2017] [Accepted: 05/15/2017] [Indexed: 06/07/2023]
Abstract
A magnetic resonance imaging (MRI) simulator, which reproduces MRI experiments using computers, has been developed using two graphic-processor-unit (GPU) boards (GTX 1080). The MRI simulator was developed to run according to pulse sequences used in experiments. Experiments and simulations were performed to demonstrate the usefulness of the MRI simulator for three types of pulse sequences, namely, three-dimensional (3D) gradient-echo, 3D radio-frequency spoiled gradient-echo, and gradient-echo multislice with practical matrix sizes. The results demonstrated that the calculation speed using two GPU boards was typically about 7 TFLOPS and about 14 times faster than the calculation speed using CPUs (two 18-core Xeons). We also found that MR images acquired by experiment could be reproduced using an appropriate number of subvoxels, and that 3D isotropic and two-dimensional multislice imaging experiments for practical matrix sizes could be simulated using the MRI simulator. Therefore, we concluded that such powerful MRI simulators are expected to become an indispensable tool for MRI research and development.
Collapse
Affiliation(s)
- Ryoichi Kose
- MRTechnology Inc, 2-1-6 B5 Sengen, Tsukuba 3050047, Japan
| | - Katsumi Kose
- Institute of Applied Physics, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 3058573, Japan.
| |
Collapse
|
244
|
Ginami G, Neji R, Phinikaridou A, Whitaker J, Botnar RM, Prieto C. Simultaneous bright- and black-blood whole-heart MRI for noncontrast enhanced coronary lumen and thrombus visualization. Magn Reson Med 2017; 79:1460-1472. [PMID: 28722267 PMCID: PMC5811778 DOI: 10.1002/mrm.26815] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 06/07/2017] [Accepted: 06/08/2017] [Indexed: 12/18/2022]
Abstract
PURPOSE To develop a 3D whole-heart Bright-blood and black-blOOd phase SensiTive (BOOST) inversion recovery sequence for simultaneous noncontrast enhanced coronary lumen and thrombus/hemorrhage visualization. METHODS The proposed sequence alternates the acquisition of two bright-blood datasets preceded by different preparatory pulses to obtain variations in blood/myocardium contrast, which then are combined in a phase-sensitive inversion recovery (PSIR)-like reconstruction to obtain a third, coregistered, black-blood dataset. The bright-blood datasets are used for both visualization of the coronary lumen and motion estimation, whereas the complementary black-blood dataset potentially allows for thrombus/hemorrhage visualization. Furthermore, integration with 2D image-based navigation enables 100% scan efficiency and predictable scan times. The proposed sequence was compared to conventional coronary MR angiography (CMRA) and PSIR sequences in a standardized phantom and in healthy subjects. Feasibility for thrombus depiction was tested ex vivo. RESULTS With BOOST, the coronary lumen is visualized with significantly higher (P < 0.05) contrast-to-noise ratio and vessel sharpness when compared to conventional CMRA. Furthermore, BOOST showed effective blood signal suppression as well as feasibility for thrombus visualization ex vivo. CONCLUSION A new PSIR sequence for noncontrast enhanced simultaneous coronary lumen and thrombus/hemorrhage detection was developed. The sequence provided improved coronary lumen depiction and showed potential for thrombus visualization. Magn Reson Med 79:1460-1472, 2018. © 2017 International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Giulia Ginami
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - Radhouene Neji
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Alkystis Phinikaridou
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - John Whitaker
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - René M Botnar
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
245
|
Weigel M, Bieri O. Spinal cord imaging using averaged magnetization inversion recovery acquisitions. Magn Reson Med 2017; 79:1870-1881. [PMID: 28714105 DOI: 10.1002/mrm.26833] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Revised: 06/19/2017] [Accepted: 06/19/2017] [Indexed: 11/06/2022]
Abstract
PURPOSE To establish a novel approach for fast high-resolution spinal cord (SC) imaging using averaged magnetization inversion recovery acquisitions (AMIRA). METHODS The AMIRA concept is based on an inversion recovery (IR) prepared, segmented, and time-limited cine balanced steady state free precession sequence. Typically, for the fastest SC imaging without any signal averaging, eight consecutive images in time with an in-plane resolution of 0.67 × 0.67 mm2 and 6 mm to 8 mm slice thickness are acquired in 51 s. AMIRA does not require parallel acquisition techniques. RESULTS AMIRA measures eight images of remarkable tissue contrast variation between spinal cord gray (GM) and white matter (WM) and cerebrospinal fluid (CSF). Following the AMIRA concept, averaging the first IR contrast images not only improves the signal-to-noise ratio but also offers a surprising enhancement of the contrast-to-noise ratio between GM and WM, whereas averaging the last images considerably improves the contrast-to-noise ratio between WM and CSF. These observations are supported by quantitative data. CONCLUSION The AMIRA concept provides 2D spinal cord imaging with multiple tissue contrasts and enhanced contrast-to-noise ratios with a typical 0.67 × 0.67 mm2 in-plane resolution and a slice thickness between 4 mm and 8 mm acquired in only 1 to 2 min per slice. Magn Reson Med 79:1870-1881, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Matthias Weigel
- Department of Radiology, Division of Radiological Physics, University of Basel Hospital, Basel, Switzerland.,Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Oliver Bieri
- Department of Radiology, Division of Radiological Physics, University of Basel Hospital, Basel, Switzerland.,Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| |
Collapse
|
246
|
Quantum-mechanical simulations for in vivo MR spectroscopy: Principles and possibilities demonstrated with the program NMRScopeB. Anal Biochem 2017; 529:79-97. [DOI: 10.1016/j.ab.2016.10.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 08/24/2016] [Accepted: 10/07/2016] [Indexed: 11/19/2022]
|
247
|
Heule R, Pfeuffer J, Bieri O. Snapshot whole-brain T1relaxometry using steady-state prepared spiral multislice variable flip angle imaging. Magn Reson Med 2017; 79:856-866. [DOI: 10.1002/mrm.26746] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 04/11/2017] [Accepted: 04/13/2017] [Indexed: 01/05/2023]
Affiliation(s)
- Rahel Heule
- Division of Radiological Physics; Department of Radiology, University Hospital Basel, University of Basel; Basel Switzerland
- Department of Biomedical Engineering; University of Basel; Basel Switzerland
| | - Josef Pfeuffer
- Siemens Healthcare, Application Development; Erlangen Germany
| | - Oliver Bieri
- Division of Radiological Physics; Department of Radiology, University Hospital Basel, University of Basel; Basel Switzerland
- Department of Biomedical Engineering; University of Basel; Basel Switzerland
| |
Collapse
|
248
|
Buonincontri G, Schulte RF, Cosottini M, Tosetti M. Spiral MR fingerprinting at 7T with simultaneous B1 estimation. Magn Reson Imaging 2017; 41:1-6. [PMID: 28414052 DOI: 10.1016/j.mri.2017.04.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 04/11/2017] [Accepted: 04/11/2017] [Indexed: 11/29/2022]
Abstract
Magnetic resonance fingerprinting is an efficient, new approach for quantitative imaging with MR. We aimed to extend this technique to cases with B1+ inhomogeneities within the imaging volume. Previous approaches have used abrupt changes in flip angles to estimate the B1+ field simultaneously with T1 and T2, using a Cartesian approach in a small-animal scanner at 4.7T. Here, we evaluated whether a similar approach would be suitable for imaging human brains using spiral readouts with a 7T scanner. We found that our modified scheme could significantly reduce the adverse effects of B1+ inhomogeneities even in extreme cases, reducing both the bias and the variance in T2 estimations by an order of magnitude when compared to literature methods. Acquisitions used less than 1.5W/kg SAR and could be performed in 12s per slice. In conclusion, our approach can be used to perform quantitative imaging of the brain at 7T in a short time, simultaneously estimating the B1+ profile.
Collapse
Affiliation(s)
| | | | - Mirco Cosottini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy; IMAGO7 Foundation, Pisa, Italy
| | - Michela Tosetti
- IRCCS Stella Maris Foundation, Pisa, Italy; IMAGO7 Foundation, Pisa, Italy
| |
Collapse
|
249
|
Teixeira RPAG, Malik SJ, Hajnal JV. Joint system relaxometry (JSR) and Crámer-Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T 1 and T 2 estimation. Magn Reson Med 2017; 79:234-245. [PMID: 28303617 PMCID: PMC5763350 DOI: 10.1002/mrm.26670] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 01/30/2017] [Accepted: 02/13/2017] [Indexed: 12/13/2022]
Abstract
Purpose This study aims to increase the precision of single‐compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer‐Rao lower bound (CRLB). Methods Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. Results Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. Conclusions Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of
ρ,T1,T2, and B0 in an 11‐min examination, making the approach appealing for potential clinical use. Magn Reson Med 79:234–245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Rui Pedro A G Teixeira
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| | - Shaihan J Malik
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - Joseph V Hajnal
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| |
Collapse
|
250
|
Drobnitzky M, Klose U. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI. Med Phys 2017; 44:873-885. [DOI: 10.1002/mp.12095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 12/13/2016] [Accepted: 12/23/2016] [Indexed: 11/09/2022] Open
Affiliation(s)
| | - Uwe Klose
- Department of Diagnostic and Interventional Neuroradiology; University Hospital Tübingen; Tübingen 72076 Germany
| |
Collapse
|